Sei sulla pagina 1di 13

CRISTIAN

PIPE
Sch. 1Os m 10 m 20 m 30 m 40 m 80 m

ELBOW
90 45 90 45 90 45

TEE

Reducer

CAP

WN FLANGE

TOTAL
219.80 EQ.
10S 40

CO/EC
10S 40

80 150# 300# 600# 900#

10S

40

80

80 10S 40 80

pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs pcs

" '' 1'' 1'' 2'' 2'' 3'' 4'' 5'' 6'' 8'' 10'' 12'' 14'' 16'' 18'' 20'' 22'' 24'' 26'' 28'' 30'' 32'' 34'' 36'' 38'' 40'' 42'' 44'' 46'' 48''

5.0

1.0

2.0

W.OLET

r R

Main DIAMETER Branch Diameter

2xR
Main pipe = 22" 90 branch = 20"
48'' 1219.2

2xr
24'' 609.6

1219.2

609.6

Suplimentary length to be cut out.

x VALUE w VALUE

527.93 557.30

R -x = 81.6709 Thickness Quoted Length 845 Branch Length 318.07 Branch Length
Main pipe = 20" 45 branch = 8"

287.70
Iuhas Cristian Bonny

24''

o be cut out. mm mm

ENTER DATA
ANGLE 90 ANGLE 45
Iuhas Cristian Bonny -Island 2001

Particular case: 14" ELBOW 900 with 10" TRUNION Elbow 90


6''

Trunion
4"

ADITIONAL LENGTH x= 101.80 H= 134.58

QUOTED LENGTH 90 CUTTING LENGTH 191.80

Drawing : Irimia Anton Program: Cristian Iuhas Bonny Island 2001

SHELL STANDARD FOR REFINERY COMPLEX. NOTE :


1 2

VENT HOLE

R = B = D1 = E =

4" 4" 228 Full shall

Head pipe Branch mm encirclement be used.

3 4

Pad material shall be the same as the main p Reinforcement pads may be divided into halv with a longitudinal welded seam, and ventho on each half. Branch attachement welds shall be in with ANSI B31.3 For sizes not shown, consult with

Reinforcing pad thickeness shall not be less than the thicknes of the header. The reinforcing pad material shall be the same nominal material as the header and equal or higher stress value.

NIGERIA LNG PROJECT


NOMINAL SIZE
BRANCH 90 BRANCH 45

WIDTH ' L' [mm]


1. The reinforcing pad width 'L' shall not be less than that specified . 2. The pad shall be positioned so that the top of the pad extends an equal distance from outside surface of the branch on either its side. Iuhas Cristian Bonny -Island 2001

NDARD FOR REFINERY COMPLEX.

Pad material shall be the same as the main pipe. Reinforcement pads may be divided into halves with a longitudinal welded seam, and venthole

Branch attachement welds shall be in accordance with ANSI B31.3 For sizes not shown, consult with sttress analyst.

NIGERIA LNG PROJECT


NOMINAL SIZE
BRANCH 90 BRANCH 45

4''
214.30 mm 261.64 mm
50

WIDTH ' L' [mm]

h 'L' shall not be less than that specified . ed so that the top of the pad extends an ide surface of the branch on either its side.

Cristian Bonny -Island 2001

LR L

ELBOW 90 1'' 57 mm
FLANGE 150#

CLEAR
ADD EXTR.

RAPID CALCULATOR

ADD 57 57 350

EXTRACT

RESULT
464
D ELET E

WN

236 2205 6270 350 300 402 334 485 190 200 240 1750 440 555

4''

76 mm 57 mm 140 mm
O.D. OD THK

TEE 1'' RED. 6''


SIZE 10''

SCH 20

273.00 136.50 6.35

SS 2"-20" 24" 30" CS&ITCS 2"- 16" >18"

WELDOLET 20''

127
VALVE

600#
8''

GLOBE

660.00 13957
Iuhas Cristian Bonny

464

6m - 8m 6 m 12m | 6m 6m CS&ITCS 11m-13m 12m

Iuhas Cristian Bonny -Island 2001

SIZE " 1" 1"

NIPOFLANGE WEIGHT [Kg] 150 300 600 3.42 4.09 4.79 5.49 7.72

NIPOLET " 1.92 1" 2.99 1" 4.42

Kg

RANDOMS SIZE
CS 3"
11954 12055 11957

4"
12053 12042 12045

24"
11835 11825 11830

SS

6" 6020

10"
6560 6295 6710 6785

20"
6020 6042 6045

24"
6015 6020 6025

ITCS

2"
12045

6"
13043

8"
13500 13138 12972

18"
9225

Potrebbero piacerti anche