Sei sulla pagina 1di 11

EMT CO.

, LTD

MESSAGE FROM THE MANAGEMENT GROUP


We, EMT Co., Ltd. are emerging as one of the most reliable and specialized firms in the field of electrical equipments for distribution system.....

It is our great pleasure to introduce ourself, EMT Co., Ltd. to you through this message. We, EMT, have been engaged in manufacturing and trading equipment for distribution system. Especially, SF6 Gas Load Break Switch, Interrupter Switch, Lightning Arrester, Automatic Sectionalizing Switch, Sectionalizer, Cut-Out Switch for over thirty years and enjoy a good reputation as a leading firm specializing in this line of business. We believe that through our steady and sincere way of conducting business we can enjoy a good reputation among the manufacturers and customers as we have been doing. For the past 35years we have exerted to extend and modernize production 35years, facilities and improve technical and quality standards of electrical equipment. As a result, our activities including the remarkably voluminous contracts for the supply of our products with our cooperating companies both at home and abroad have been successfully completed or in progress. In accordance with the acquired ISO-9001 certificate, we have been making every effort to build up the first-ranked position in the electrical business in Korea as well as extend our business to overseas market around the world with our diverse marketing policy for the better future. We would like to assure you that our activities such as above mentioned exertion will be continued as long as we lives. Also we sure that our faithful service as true specialists will bring profits not only to ourselves and our customers but also to the entire society as a whole sweating to provide our customers with the perfect products and sincere services in the present and the future.

Sincerely Yours,

EMT CO., LTD

We first would like to express our sincere gratitude to our customers as it is owing to your favorable support and selection of our products that we have grown to be a dependable manufacturer. We W are well convinced that the b way we can requite your ll d h h best favor is to achieve performance as one of the top specialists in the field of electrical equipments for distribution systems in line with the ISO-9001 certification. We believe that our work is a trial but an important one. We, as a specialized firm participating in the production and supply of the power and energy as well as vital for industrial advancement, shall make untiring and constant efforts in pursuing research, development and perfect service. All the members of EMT Co., Ltd. shall execute the following quality policy in compliance with the corporate qua ty po cy o wa s e ce e ce a w t quality policy forwards excellence and with a requirements to equ e e ts meet the customers satisfaction;

Quality Policy

We shall create utmost customer satisfaction by providing the best products and service We shall make continuous pursuit of quality innovations and maintain a stable process by advanced quality tools. We shall establish and pursue the quality objectives, which need to be accomplished through regular procedure of confirmation. This quality manual is approved by president and also accompany with the responsibility for quality system and quality control.

EMT Co., Ltd. President Heang Hoon, Cho

EMT CO., LTD

Business Introduction
We, EMT Co., Ltd. are at our best from a true specialists aspect with advanced technology and accumulated experience of 35-years
In the year of 1965, we first founded the firm, namely Shin-A enterprise, starting to manufacture electrical equipment for distribution di t ib ti system under th poor circumstance of a technological foundation. However, nowadays, we have succeeded in t d the i t f t h l gi l f d ti H d h d di becoming one of the most prominent firms in the nation. Our responsibility is to develop, innovate and supply improved heavy electrical equipments: in order to bring and boost the productivity and quality through supplying the choicest produce free from power failure and accidents. Taking on such an important role, we are making our best efforts with untiring research and development work along with a perfect quality control system. As a result of that, our products; Non-Grounding High Voltage Distribution equipments, 25.8KV Disconnecting Switches, lightning Arresters, 25.8KV Auto Section Switches, 25.8KV Interrupter Switches, 25.8KV Automatic Line-Sectionalizers and 25.8KV SF6 Gas Load Break Switches have become the most competitive among other similar products. We will do our best for both manufacturing and enhancing service for our customers and faithfully playing a role as a specialized firm, both in name and reality.

Research and Development


We believe in saying harvested as good and much as seeded Continuous research will bring the promise of tomorrow.
It took substantial years before the trade mark EMT become trusted by customers. However, much more untiring day-to-day effort is needed in order to gain and enjoy the trust by customers for the betterment in the field of electrical equipment industry. Therefore, we aggressively invest in the research of Hi-tech and advanced technologies. The way to continue innovation in the plant facilities, while making contracts in technological introduction with leading specialized manufacturers abroad, staying one step ahead of our competitors, is a part of our policy. In addition, through the separated operation and management of Research and t d ti d t fR h d Development Div., we will do our best to try to bring up and develop new equipments and systems.

Installation
The most outstanding products are born by means of having distinguished machinery. machinery

EMT, in order to attain advanced technologies and realize whole-class products, has aggressively invested in introduction of advanced installations and machinery. With the result of that, weve got a prize as a distinguished service company by the government of Korea many times. We will not only make continual efforts in the achievement of double the productivity through an automation of machinery and installation hereafter, but also in the keeping of uniform and stabilized quality in the products.

EMT CO., LTD

Company History
Apr. 1965 : Founded by the name of Shin-A Electronic Enterprise at Jangsa-dong, Seoul and started manufacturing various switches, breakers and protective devices. Dec. 1970 : Changed the name of the company to Shin-A Electronic IND. Co., Ltd. Jan. 1976 : Signed technical license agreement with Togami Electric Manufacturing Co., Ltd. Japan for manufacturing Automatic oil breaker with pole grounding and protection against overload. May. 1979 : Nominated as professional Mechanical factory of small & medium enterprises from Government, Ministry of Commerce &I d Industry. Nov. 1979 : Nominated as Manufacturer of newly developed machine (Interrupter switch) from Government, Ministry of Commerce & Industry. Sep. 1980 : Factory moved to Banwol Industrial Complex in Ansan City. May. 1982 : Signed technical license agreement with Otowa Electric Co., Ltd. Japan for manufacturing Lightning Arrester for 18kV and 9kV. Aug. 1983 : Nominated as promising of modernization of small & medium enterprises by Small & Medium Enterprises Promotion Corporation. Feb. 1984 : Approved plan for implementation of modernization of small & medium enterprises by Small & Medium Enterprises Promotion Corporation. Dec. Dec 1984 : Acquired patent right of Auto Section Switch for 25.8kV distribution line from Government 25 8kV Government. Aug. 1985 : Signed technical license agreement with Togami Electric Manufacturing Co., Ltd. Japan for manufacturing SF6 gas load break switch. Feb. 1986 : Acquired patent right of Arc chamber mechanism of Air Break Switch. Dec. 1989 : Signed technical license agreement with Osaka Fuse Co., Ltd. Japan for manufacturing low voltage fuse. Jul. 1990 : Acquired patent right of Pressure sensor mechanism of SF6 gas load break switch. Jul. 1990 : Acquired patent right of Driving arm mechanism of SF6 gas load break switch. Apr. 1991 : Signed technical license agreement with ABB Company, USA for manufacturing Self-diagnostics automatic circuit breaker. May. 1992 : Signed technical license agreement with Otowa Electric Co., Ltd. Japan for manufacturing Surge Shelter. Nov. Nov 1993 : Signed technical license agreement with G&W electronic Company, USA for manufacturing Gas insulation load switch Company for ground. Aug. 1993 : Signed technical license agreement with Raychem GmbH, USA for manufacturing 21kV and 10kV polymeric Lightning Arresters. Jun. 1995 : ISO 9001 certified by Det Norske Veritas, Netherlands. Jul. 1996 : Signed technical transfer agreement with Feuchtwanger Industries(1994)Ltd. in Israel for SF6 load break switch.(GSS-M) May 2000 : Changed the name of EMT Co., Ltd. ( All Technology & Manufacturing Facilities are occupied from SHIN-A Co., Ltd. May 2006 : Development of AMR ( Automatic Meter Reading ) System based on PLC Technology by R&D Project of Government Dec. 2009 : Development of SCADA system

Award Record
Aug. 1972 : Won a prize as an excellent company in the field of science and technology (from the president of Korea) Sep. 1981 : Won a prize as an exemplary company of cooperation between labor and management (from the Minister of Ministry of Labor Affairs) Apr. 1983 : Won a prize of bronze tower for industrial merits (from the president of Korea) Aug. 1984 : Won a prize of silver tower for industrial merits (from the president of Korea) Nov. 1985 : Won a prize of silver tower of merits as a distinguished service company in the science and technology field (from the p g p y gy ( Minister of Ministry of science and technology) Jul. 1986 : Won a prize as a distinguished service company of an industrial disaster-prevention (from the president of Korea) Apr. 1989 : Won a prize as a distinguished service company in the electric field (from the president of Korea) Apr. 1992 : Won a medal of merits as a distinguished service company in the field of electric and electronic industry (from the president of Korea) Sep. 1992 : Won a prize of golden tower as a distinguished service company an industrial disaster-prevention (from the Minister of Ministry of Labor Affairs) Apr. 1995 : Won a prize of tower of merits as a most distinguished service company in the electric industrial promoting competition (from Korea Electrical Manufacturing Association) Jan. 1997 : Named as the top-ranked company of cooperation between labor and management (from the Minister of Ministry of Labor Affairs) Oct. 1999 : Won a golden prize for Labor Union (from the Minister of Ministry of Labor Affairs)

EMT CO., LTD

SF6 Gas Load Break Switch (Manual Type)


Rated voltage : 15/25/36 kV Rated frequency : 50/60Hz Rated current : 200/400 /600 A Rated short-time current : 12.5kA Rated 32.5kA Rated making current : 32 5kA Impulse withstand voltage(BIL) : 110/150/170kV
EMTs GSS, which is operated electrically through remote controller and manually, is used for load braking of overhead distribution lines. This is very compact owing to the introduction of simple extinguishing mechanism ensured by the high insulation and superior interrupting characteristics of SF6 Gas. EMTs GSS has been tested by IEC60265-1, ANSI37.41, KSC4509, JIS C4304 and has acquired the ISO-9001 as International quality system certification.

SF6 Gas Load Break S itch (Remote Controlled Type) Switch T pe)
Rated voltage : 15/25/36 kV Rated frequency : 50/60Hz Rated current : 200/400 /600 A Rated short-time current : 12.5kA Rated making current : 32.5kA Impulse withstand voltage(BIL) : 110/150/170kV

EMTs AGSS can be manually operated and remotely controlled with SCADA system. 3 CT for Current sensing are integrated and fault current detecting system is available with fault indicator. .Also, Voltage sensor shall be available to install for voltage indication. If our RTU is connected to controller, then AGSS is Ready for SCADA system in GSM/CDMA/GPRS network. Tested by IEC60265-1 specification.

SF6 Gas Pad Mounted Type Load Break Switch (Underground System)
Rated voltage : 15/25/36 kV Rated frequency : 50/60Hz Rated current : 400/ 630A Rated short-time current : 12.5kA Rated making current : 32 5kA 32.5kA

EMTs SF6 Gas Pad Mounted Type Load Break Switch is installed for underground cable system. There are manual type & Remotely controlled type with SCADA system as 3 way 3 switch, 4 way 4 switch. Pad Mounted Type LBS shall be applicable for RMU (Ring Main Unit). FEATURES Totally sealed and dead-front enclosure construction. Simple and easy operation using by operation handle or hook stick.

EMT CO., LTD

Air Type Load Break Switch (Interrupter Switch) yp ( p )


Rated voltage : 15/25/36 kV Rated frequency : 50/60Hz Rated current : 400/ 630A Rated short-time current : 25 kA Impulse withstand voltage(BIL) : 110/150/180 kV Operation : Manually / Motorizing Operation

FEATURES Economical Load Break Switch Compact Air Type Arc Chamber Arc Chamber can be fixed on Movable Contactor, or Fixed Contactor Manual operation, or Motorizing Operation (Optional) * Available for SCADA system Maintenance Free Maintenance

Automatic Recloser
Rated voltage : 15kV, 25kV, 36kV Rated frequency : 50/60Hz Rated current : 400A/630/*1250 A Rated /*20 Rated Interrupting Current : 12.5 KA / 20 kA Impulse withstand voltage(BIL) : 110/150/170 kV
EMTs Pole Top Auto-Recloser is installed for Automatic tripping as equipped Time Current Curve with SF6 Gas type, or Polymer Type. Auto Recloser shall be able to automatically trip on Overload/Phase Fault /Ground Fault. Auto Recloser can automatically reclose as Reclosing controller of programmed reclosing sequence to minimize SAIDI, SAIFI. FEATURES A t Automatic F lt T i as Ci it B k with T C C ti Fault Trip Circuit Breaker ith T.C Curve Automatic Reclosing as Programmed sequence Available of SCADA system with RTU (or, Integrated RTU)

Automatic Line Sectionalizer


Rated voltage : 15kV/25kV/36kV Rated frequency : 50/60Hz Rated current : 400A /630A Rated short-time current : 12.5 kA Impulse withstand voltage(BIL) : 110/150/170 kV Rated interrupting current : 900A

FEATURES Phase fault/ Ground Fault/Sensitive Fault counting level can be set . Automatic trip in setting count in coordination with recloser / Circuit Breaker . Prevent Fault Count for Inrush Current with Inrush current restrained function Applicable Standards ANSI C37.63

EMT CO., LTD

SCADA System(Supervisory Control and Data Acquisition)


EMTS SCADA (supervisory control and data acquisition) system is useful with our RTU, or integrated RTU controller for Remotely control and monitoring Current, Voltage, Status of LBS/RECLOSER /SECTIONALIZER etc. by RF/GSM/CDMA/INTERNET communication network. FEATURES Remotely ON / OFF operation Monitoring of Current, Voltage on distribution line Monitoring status of LBS/RECLOSER/SECTIONALIZER/CB # Status : Trip event/Fault report/Gas Low / Door open / Battery Low etc. # Communication Network : RF/GSM/GPRS/CDMA/INTERNET etc.

RTU( Remote Terminal Unit )


EMT RTU can be easily adaptable with any LBS/SECTIONALIZER/RECLOSER/CB Controller for SCADA system Applicable for RF/GSM/GPRS/CDMA communication network. Our own Protocol with our operating software, or DNP 3.0 protocol FEATURES Very Compact and Simple applicable for LBS/SECTIONALIZER/RECLOSER/CB Remotely ON/OFF Operation for Two Switches Monitoring DATA of Current (Voltage) value Status of LBS/SECTIONALIZER/RECLOSER RS232 Connection / pulse Mode Switching DNP 3.0 protocol

AMR(Automatic Meter Reading) System


EMTS Automatic Meter Reading(AMR) System is consisting of a Host Central Station(HCS), Data Concentrator Units (DCU) and Meter Interfacing Units (MIU) built-in, or External in Electronic Digital Meter/Mechanical Meter/Electronic, Mechanical Meters of flexibility and expandability based on PLC (Low Voltage Power Line Communication Technology) for Low Voltage Customers Downstream Communication of DCU is PLC technology, upstream communication gy, p of DCU(MDCU) is RF/GSM/GPRS/CDMA/Internet network. For Low voltage customer AMR system. For High Voltage Customer AMR system, GSM/GPRS/CDMA network shall be adapted.

Power loss Analysis System & Remote Switching (Optional) EMT AMR system shall be able to provide analysis data of power loss based on each distribution transformer as AMR system operation software Energy cheating detecting system shall be applicable with AMR system software. system. Economical and Flexible Application EMT AMR system shall be able to apply for the Existing Mechanical Meter with Internal PULSE GENERATOR, or External PULSE GENERATOR. Also, Electronic Meter with Pulse Out.

EMT CO., LTD

SFI (Smart Fault Indicator)


Rated voltage : 12kV ~ 36kV Rated current : 5A ~ 630A Fault Current Pick Up Tap : 50, 100, 200, 300A Set Operating Signal Time : 30min, 1 hour, 2 hour, 4hour Self Power Charging : DC 12V
FEATURES Detecting of over current fault sensing (Detecting time : 20~25 ms) Settable Time for make audible & Visible signal even for instantaneous Fault Settable current to pick up fault current Self power rechargeable device from load current. Remote monitoring of fault indicator signal ( RF, GSM Network )

Portable SF6 Gas Load Break Switch


Rated voltage : 15/25 kV Rated frequency : 50/60Hz Rated current continuous : 200A, 400A Rated short-time current : 12.5kA Rated making current : 25kA
EMTs portable type SF6 Gas Load Break Switch is useful for Temporary Cabling work and non power outage work . FEATURES Live line indication Phasing indication Safety lock by manual operation Loose phasing indication Internal arching safety device

Operation counter Gas pressure gauge Internal and outsource charging Safety lock for low pressure(Automatically) Live line indication in case of battery voltage out

Cut Out Switch (Drop Out Type)


Rated voltage nominal : 15/25/36 kV Rated frequency : 50/60Hz Rated continuous current : 100A Rated interrupting current : 12.5 kA Rated
EMTs Cutout Switch is a safe device installed to primary side transformer for protection of the transformer and customers facilities from secondary short-circuit fault of transformer and overload and a outdoor cross-arm mounting, live working, hook-stick operated with load-buster, open type with drop out fuse holder. EMT Cutout Switch has been tested and meet all requirements of IEC, ANSI and NEMA. FEATURES Porcelain Insulator / Silicone Composite Insulator Available Stainless Steel / Zinc Iron Coated Steel Mounting Bracket

EMT CO., LTD

High Voltage Air Break Switch (KST Type)


Rated voltage nominal : 7.2KV Rated frequency : 50/60Hz Rated current : 200A, 300A, 400A
EMTs High Voltage Air Break Switch is a manually operating switch. Air type Load Break Switch is supplied to Rail Way company.. Main technology is from JAPAN TOGAMI Electric Manf Co Ltd Manf. Co. Ltd.

FEATURES OIL. SF6 Gas Free / Air Type Load Break Switch (Fully enclosed Type) . Applicable standards KSC4510, JISc4605

Porcelain Type Lightning Arresters


Type Rated Voltage(KV) Max. Impulse spark over voltage (KV Crest) Standard 1.2 x 50 Front of wave Discharge voltage at 2.5KV(KA Crest) BV7A 7.5 27 31 27 BV-9A BV 9A 9 32.5 38 32.5 BV-18A BV 18A 18 65 75 65 54 65 GL-15 GL 15 15 95 GL-18 GL 18 18 125

Standards

IEC 99-1, ESB 153

ANSI / IEEE C 62.11 ESB 153

EMT offers a line of porcelain distribution Surge Arrestors with SIC varistors(Gap Type) and Zinc-oxide varistors(Gapless Type), for protection of distribution line system. FEATURES High reliability and excellent durability High dielectric strength due to posses the wet process porcelain housing Excellent non corrosion due to complete stainless steel sealing cap Economic price with easily portable due to compact size

Polymer Type Lightning Arresters


Type SHDA-18 SSPA-18 SHDA-21 SSPA-21 SHDA-24 SSPA-24 Rated Voltage(KV) 18 18 21 21 24 24 Nominal Disc harge Current (KA) 5 10 5 10 5 10 5 10 5 10 5 10 Residual Voltage (KV) 5KA 10KA 54 60 54 60 64 69 64 69 72 80 72 80 Lightning Impulse Withstand Voltage (KV, Crest) 150 150 150 150 150 150 Power Frequency Withstand Voltage (KV, Crest) 70 70 70 70 70 70

FEATURES EMTs Polymer Arrester is the design avoid free air space which eliminates the possibility of failures due to moisture ingress. Out-door type polymer arresters prevent the power lines from fault due to the lightning and line switching. Especially out-door type in heavy polluted area provide excellent protection for equipments. i t In-door type polymer arresters for the switchgear protection are installed in a MGSG and a cubicle.