Sei sulla pagina 1di 6

Extract from the online catalog

FLT-CP-3C-350
Order No.: 2859725

http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2859725

Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 3-phase power supply networks with PE and N (L1, L2, L3, PEN) installed in one cable.

Product notes Commercial data EAN Pack Customs tariff Weight/Piece Catalog page information 4017918956448 1 pcs. 85363030 1.1694 KG Page 22 (TT-2009) http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. WEEE/RoHS-compliant since: 05/10/2006

Technical data Standards Housing material Inflammability class acc. to UL 94 Color PBT V0 gray

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 1 / 6 Feb 17, 2010

FLT-CP-3C-350 Order No.: 2859725

http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2859725

Standards for air and creepage distances

DIN VDE 0110-1 IEC 60664-1: 1992-10 IEC 61643-1

Surge voltage category Pollution degree Degree of protection Mounting type Design Number of positions Ambient temperature (operation) Message surge protection faulty Direction of action Width Height Length Pitch unit Protective circuit IEC category EN type Lightning protection class Nominal voltage UN Arrester rated voltage UC (L-PEN) UT (TOV-proof) Nominal frequency fN

III 2 IP20 DIN rail 35 mm DIN rail module, two-section, divisible 3 -40 C ... 80 C Optical, remote indicator contact 3L-N/PE 106.90 mm 70.00 mm 95.80 mm 6 Div.

I + II T1 + T2 T1 + T2 I /100 kA (TN-C) 240 V AC (230/400 V AC ... 240/415 V AC) 350 V AC 415 V (5 sec.) 50 Hz 60 Hz

Rated load current Nominal discharge surge current In (8/20) s (LPEN) Lightning test current (10/350) s, charge Lightning test current (10/350) s, specific energy Lightning test current (10/350) s, peak value limp Lightning test current (10/350) s, charge Lightning test current (10/350) s, specific energy Lightning test current (10/350) s, peak value limp

125 A ( 55C) 75 kA (all channels) 37.5 As 1.40 MJ/ 75 kA (3-pos.) 12.5 As 160.00 kJ/ 25 kA (1-pos.)

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 2 / 6 Feb 17, 2010

FLT-CP-3C-350 Order No.: 2859725

http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2859725

Protection level UP (L-PEN) Residual voltage (L-PEN)

1.5 kV 1.3 kV 1.1 kV (10 kA) 1 kV (5 kA) 1 kV (3 kA)

Clamping voltage SVR (L-PEN) Response time (L-N) Max. required backup fuse with branch wiring Max. required backup fuse with V-type through wiring Recommended backup fuse maximum Short circuit resistance ICC with max. backup fuse (effective) Follow current quenching capacity If (L-PE)

0.9 kV 25 ns 315 A (gL / gG) 125 A (gL / gG) 160 A (gL/gG, 125 A with serial through wiring) 25 kA 25 kA (264 V AC) 3 kA (350 V AC)

Connection, protective circuit Type of connection Connection type IN Connection type OUT Connection method Screw thread Tightening torque, min Stripping length Conductor cross section stranded min. Conductor cross section stranded max. Conductor cross section solid min. Conductor cross section solid max. Conductor cross section AWG/kcmil min. Conductor cross section AWG/kcmil max Remote indicator contact Connection name Schaltfunktion_Int Type of connection Screw thread Tightening torque, min Remote fault indicator contact PDT contact Plug-in/screw connection via COMBICON M2 0.25 Nm Screw terminal blocks Biconnect screw terminal block Biconnect screw terminal block Biconnect terminal block M5 4.5 Nm 18 mm 2.5 mm 25 mm 2.5 mm 35 mm 13 2

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 3 / 6 Feb 17, 2010

FLT-CP-3C-350 Order No.: 2859725

http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2859725

Stripping length Conductor cross section stranded min. Conductor cross section stranded max. Conductor cross section solid min. Conductor cross section solid max. Conductor cross section AWG/kcmil min. Conductor cross section AWG/kcmil max Maximum operating voltage Umax. AC Maximum operating voltage Umax DC Max. operating current Imax

7 mm 0.14 mm 1.5 mm 0.14 mm 1.5 mm 28 16 250 V AC 125 V DC 1 A AC (inductive) 1 A AC (ohmic) 30 mA DC (inductive) 0.2 A DC (ohmic)

Environmental conditions Standards/regulations IEC 61643-1 EN 61643-11 UL 1449 Certificates / Approvals

Certification Diagrams/Drawings Dimensioned drawing

CB, CCA, CUL, GOST, KEMA, UL

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 4 / 6 Feb 17, 2010

FLT-CP-3C-350 Order No.: 2859725

http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2859725

Circuit diagram

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 5 / 6 Feb 17, 2010

FLT-CP-3C-350 Order No.: 2859725

http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2859725

Address

PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg,Germany Phone +49 5235 3 00 Fax +49 5235 3 41200 http://www.phoenixcontact.com

2010 Phoenix Contact Technical modifications reserved;

PHOENIX CONTACT GmbH & Co. KG http://www.phoenixcontact.com

Page 6 / 6 Feb 17, 2010