Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Configuration Maximums
VMware vSphere 4.0
Whenyouselectandconfigureyourvirtualandphysicalequipment,youmuststayatorbelowthemaximums supportedbyvSphere4.0.Thelimitspresentedinthefollowingtablesrepresenttested,recommendedlimits, andtheyarefullysupportedbyVMware.
VMware, Inc.
Configuration Maximums
Maximum
108
3 4
29 60
40
Storage Maximums
VMFS2issupportedonESX3.0through3.5. Table 2containsconfigurationmaximumsrelatedtoESXhoststorage. Table 2. Storage Maximums
Item VMFS-General Rawdevicemapping(RDM)size Volumesize Virtualmachinespervolume Volumesperhost Extentspervolume Hostspercluster 2TBminus512B 64TBminus16K 256 256 32 32 Maximum
VMware, Inc.
Configuration Maximums
VMware, Inc.
Configuration Maximums
Maximum
Compute Maximums
Table 3containsconfigurationmaximumsrelatedtoESXhostcomputeresources. Table 3. Compute Maximums
Item VirtualCPUsperhost Virtualmachinesperhost Logicalprocessorsperhost VirtualCPUsperphysicalcore
1. Specificsolutionlimitsmaybelower;pleasecheckindividualsolutionlimitsformaximum supportedconfigurations. 2. LogicalCPUsperhost=CPUsocketsxcores/socketxthreads/core.Regardlessofthehosts configurationofCPUsockets,cores/socketorthreadsperCPUcore,thetotalnumberoflogical CPUs(hardwarethreads)maynotexceedthisnumber.LogicalCPUsinexcessofthisnumberare ignored. 3. TheachievablenumberofvCPUspercoredependsontheworkloadandspecificsofthehardware. FormoreinformationseethevSphere4.0PerformanceBestPracticesandBenchmarkingGuidelines.
Memory Maximums
Table 4containsconfigurationmaximumsrelatedtoESXhostmemory. Table 4. Memory Maximums
VMware, Inc.
Configuration Maximums
Networking Maximums
Thefollowinglimitsrepresentachievablemaximumconfigurationlimitsfornetworkinginenvironments wherenoothermorerestrictivelimitsapply.Forexample,vCenterServerlimits,thelimitsimposedby featuressuchasHAorDRS,andotherconfigurationsthatmightimposerestrictionsmustbeconsideredwhen deployinglargescalesystems. Table 5containsconfigurationmaximumsrelatedtoESXhostnetworking. Table 5. Networking Maximums
Item Physical NICs
1
Maximum
e1000NICsEthernetports(IntelPCIxNIC) e1000eNICsEthernetports(IntelPCIeNIC) igb1GBEthernetports(Intel) tg31GBEthernetports(Broadcom) bnx21GBEthernetports(Broadcom) forcedeth1GBEthernetports(Nvidia) s2io10GBEthernetports(Neterion) nx_nic10GBEthernetports(NetXen) ixgbeOplin10GBEthernetports(Intel) bnx2x10GBEthernetports(Broadcom) Infinibandports(refertoVMwareCommunitySupport) PCI VMDirectPath Devices2 PCIVMDirectPathdevicesperhost vNetwork Standard Switch Totalvirtualnetworkswitchportsperhost(vDSandvSSports) Virtualnetworkswitchportsperstandardswitch Portgroupsperstandardswitch Standardswitchesperhost vNetwork Distributed Switch Totalvirtualnetworkswitchportsperhost(vDSandvSSports) DistributedvirtualnetworkswitchportspervCenter DistributedportgroupspervCenter DistributedswitchespervCenter Hostsperdistributedswitch
1. MellanoxTechnologiesInfiniBandHCAdevicedriversareavailabledirectlyfromMellanox Technologies.PleaserefertoMellanoxforsupportstatusofInfiniBandHCAswithESX.Infiniband driversforESXihostsarenotavailable. http://www.mellanox.com 2. Theselimitsaresupportedwithstandardswitchesanddistributedvirtualswitches.
32 32 16 32 16 2 4 4 4 4 N/A1
VMware, Inc.
Configuration Maximums
Maximum
32 100 40 4 50%
32 12801 256
VMware, Inc.
Configuration Maximums
Maximum
81 81 22 42 22 4 96
VMware, Inc.
Configuration Maximums
If you have comments about this documentation, submit your feedback to: docfeedback@vmware.com VMware, Inc. 3401 Hillview Ave., Palo Alto, CA 94304 www.vmware.com Copyright 2008, 2009 VMware, Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. VMware products are covered by one or more patents listed at http://www.vmware.com/go/patents. VMware is a registered trademark or trademark of VMware, Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies. Item: EN-000103-02