Test Report

Pertaining To:

Equipment Under Test External Device Server

Model Number(s) UDS1100

MEASUREMENTS PERFORMED IN ACCORDANCE WITH THE FOLLOWING HARMONIZED EUROPEAN STANDARD (S)

Regulatory Standard(s)
EN55022: 1998 + A1: 2000 + A2: 2003 CLASS A Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment EN61000-3-2: 2000 Class A - ELECTROMAGNETIC COMPATIBILITY (EMC) Part 3-2: Limits Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) EN61000-3-3: 1995 +A1: 2001 - ELECTROMAGNETIC COMPATIBILITY (EMC) Part 3: Limits Section 3: Limitation of voltage changes, voltage fluctuations and flicker in low-voltage public supply systems, for equipment with rated current < 16 A per phase and not subject to conditional connection EN55024: 1998 +A1: 2001 +A2: 2003 Information Technology Equipment - Immunity characteristics Limits and Methods of Measurement

Certificate Number: 1111.01

PREPARED FOR:
Lantronix 15353 Barranca Parkway Irvine, CA 92618
Contact(s): Mr. Daryl Miller

PREPARED BY: Aegis Labs, Inc. 22431 Antonio Parkway B160-417 Rancho S. Margarita, CA 92688
Agent(s):

Mr. Steve Kuiper Mr. Rick Candelas Mr. Ralph Jimenez Mr. Powen Cheng
LANTR-060108CE A3
TOTAL PAGES 102

Test Report #: Test Report Revision:


REPORT BODY PAGES 38 APPENDICES A 22 B 14 C 18 D 3 E 1

F 4

G 2

The contents of this report shall not be reproduced except in full, without the written approval of Aegis Labs, Inc.
The Lantronix logo is used for identification purposes only and is a registered trademark of Lantronix.

Additional Model Numbers by similarity listed under Appendix G


Page 1 of 38 Report Number: LANTR-060108CE Revision Number: A3

TABLE OF CONTENTS
SECTION TITLE COVER SHEET...... TABLE OF CONTENTS............................................................................................ 1.0 1.01 1.02 1.03 2.0 3.0 4.0 5.0 6.0 6.1 6.2 6.2.1 6.2.2 6.3 6.4 6.5 6.6 6.7 6.7.1 6.8 7.0 7.1 7.2 7.3 7.4
7.5 7.6 7.7

PAGE 01 02 04 04 05 06 07 11 13 14 15 15 16 16 17 18 19 21 22 25 25 26 27 27 29 30 31
32 33 34

EU REGULATORY COMPLIANCE GUIDELINES..... Guidelines for testing to EN55022 Standard..... Guidelines for testing to EN55024 Standard..... Guidelines for testing to EN61000-3-2 and EN61000-3-3 Standards... SUMMARY OF TEST DOCUMENTS..................................... DEFINITIONS................................................. APPROVAL SIGNATURES.................................................. ADMINISTRATIVE DATA AND TEST DESCRIPTION.............................. DESCRIPTION OF EUT CONFIGURATION........................ Arrangement and Location of EUT and Host Equipment.. EUT Description and Configuration.......................................................................... Product Description........................................................................................... EUT Configuration............................................................................................ List of Internal EUT Sub-Assemblies and Host Equipment.................................. I/O Cabling Diagram and Description....................................................................... List of Accessory / Host Equipment Power Cables................................................ EMI Test Hardware and Software Measurement Equipment.................................... Operating Modes................................................ Emissions and Immunity Harmonic / Flicker Requirements.. TEST EQUIPMENT SETTINGS AND FUNCTIONS (RF emissions). Test Equipment State of the Instrument for Conducted Emission Measurements. Decision Tree for Peak Detector Measurements.... Test Equipment State of the Instrument for Radiated Emissions Conducted Emissions Test Setup...
Conducted Emissions Site Diagram............................................................................. Radiated Emissions Test Setup................................................................................. Radiated Emissions Site Diagram - Side View and Plan View.................................

Page 2 of 38 Report Number: LANTR-060108CE Revision Number: A3

TABLE OF CONTENTS
(Continued)
SECTION 8.0 9.0 9.1 9.2 TITLE SAMPLE CALCULATIONS IMMUNITY TEST REQUIREMENTS... General.. Performance Criteria. PAGE 36 37 37 38

APPENDICES
A
B

Test Data (12VDC Group West Power supply, MN: TRC-12-0830) Test Data (12VDC CUI Power Supply, MN: 3A-161WP12) Photographs Test Setups Calibration Correction Table Modifications And Recommendations Accreditation Certificate Additional Models Considered Under Similarities

C D E F G

Page 3 of 38 Report Number: LANTR-060108CE Revision Number: A3

1.0
1.01

EU REGULATORY COMPLIANCE GUIDELINES


Guidelines for testing to EN55022 standard

Aegis Labs, Inc. operates as both a Nevada and California Corporation with no organizational or financial relationship with any company, institution, or private individual. Testing and engineering functions provided by Aegis Labs are furnished by RF technicians and engineers with accredited qualifications and training credentials to carry out their duties. The purpose of this EN55022 standard is to protect the radio frequency spectrum 9kHz. 400 GHz. from unwanted interference generated from electrical/digital systems that intentionally or unintentionally generated RF energy. The object of this report is to publish verifiable test results of an EUT subjected to the following tests: (1) power line conducted (2) telecommunication conducted and (3) radiated emissions. The test requirements and results are specified for each power or signal port tested. The following emissions standard, normative documents and/or publications were used to conduct all tests performed on the equipment herein referred to as Equipment Under Test. Council Directive: 89/336/EEC (May 3, 1989) European Standards Organization: CENELEC Publication in the Official Journal: OJ C 246 of 2005-10-05 Reference of: 2 Harmonized Standard: EN_55022:1998+A1: 2000+A2: 2003 3 Normative References: CISPR 11:1990 CISPR 13:2001 CISPR 16-1:1993 CISPR 16-2:1996

Date of cessation of presumption of conformity of the superseded standard 01/10/2004. Generally the date of cessation of presumption of conformity will be the date of withdrawal (dow), set by the European Standards body, but attention of users of these standards is drawn to the fact that in certain exceptional cases this can be otherwise. Also note that this standard incorporates by dated or undated reference, provisions from other publications. For dated references, subsequent amendments to or revisions of any of these publications apply to this EN55024 European Standard only when incorporated in it by amendment or revision. 3 The normative documents contain provisions, which, through reference in this text, constitute provisions of this International Standard. It is recommended by CISPR that parties to agreements based upon this International Standard are encouraged to investigate the possibility of applying the most recent editions of the IEC normative documents indicated in the above passage.
Page 4 of 38 Report Number: LANTR-060108CE Revision Number: A3

1.0
1.02

EU REGULATORY COMPLIANCE GUIDELINES (Continued)


Guidelines for testing to EN55024 standard

Aegis Labs, Inc. operates as both a Nevada and California Corporation with no organizational or financial relationship with any company, institution, or private individual. Testing and engineering functions provided by Aegis Labs are furnished by RF technicians and engineers with accredited qualifications and training credentials to carry out their duties. The purpose of this report is to present information in order to prove that an adequate level of intrinsic immunity exists on the equipment under test (EUT) and shall operate as intended in its environment. The object of this report is to publish verifiable test results on an EUT defined in this report as it relates to continuous and transient, conducted and radiated disturbances, including electrostatic discharges. The test requirements and results are specified for each port considered. The following harmonized standards, normative documents and/or publications were used to conduct all tests performed on the equipment herein referred to as Equipment Under Test. Council Directive: 89/336/EEC (May 3, 1989) European Standards Organization: CENELEC Publication in the Official Journal: OJ C 246 of 2005-10-05 Reference of: 4 Harmonized Standard: EN_55024: 1998 +A1:2001 +A2:2003 5 Normative References: IEC_61000-4-2:1995 IEC_61000-4-3:1995 IEC_61000-4-4:1995 IEC_61000-4-5:1995 IEC_61000-4-6:1996 IEC_61000-4-8:1993 IEC_61000-4-11:1994 Note: All test data contained in this report is based upon following the European Normative Standards. In regard to the IEC_61000-4-X series of normative references, Aegis Labs followed the latest equivalent EN_61000-4-X harmonized standards.

Date of cessation of presumption of conformity of the superseded standard 01/10/2004. Generally the date of cessation of presumption of conformity will be the date of withdrawal (dow), set by the European Standards body, but attention of users of these standards is drawn to the fact that in certain exceptional cases this can be otherwise. Also note that this standard incorporates by dated or undated reference, provisions from other publications. For dated references, subsequent amendments to or revisions of any of these publications apply to this EN55024 European Standard only when incorporated in it by amendment or revision. 5 The normative documents contain provisions, which, through reference in this text, constitute provisions of this International Standard. It is recommended by CISPR that parties to agreements based upon this International Standard are encouraged to investigate the possibility of applying the most recent editions of the IEC normative documents indicated in the above passage.
Page 5 of 38 Report Number: LANTR-060108CE Revision Number: A3

1.0
1.03

EU REGULATORY COMPLIANCE GUIDELINES (Continued)


Guidelines for testing to EN61000-3-2, AND EN61000-3-3 standard(s)

Regarding Harmonics and Flicker emissions of the equipment under test detailed in this report, the purpose of this report is as follows: (1) to publish verifiable test results on an EUT that meets the set limits for harmonic emissions of equipment within its scope, so that, with due allowance for the emissions from other equipment, compliance with the limits ensures that harmonic disturbance levels do not exceed the compatibility levels defined in IEC61000-2-2. And (2) to publish verifiable test results that the EUT does not exceed the limits as it relates to voltage changes experienced by consumers connected at the interface between the public supply low-voltage network and the equipment users installation. The following harmonized standards; normative documents and/or publications were used to conduct all tests performed on the equipment herein referred to as Equipment Under Test. Council Directive: 89/336/EEC (May 3, 1989) European Standards Organization: CENELEC Publication in the Official Journal: OJ C 246 of 2005-10-05 Reference of 6Harmonized Standard: EN61000-3-2: 2000 Normative References: EN61000-4-7: 2002 Reference of 7Harmonized Standard: EN61000-3-3: 1995+A1: 2001 Normative References: IEC61000-4-15: 1997 +A1: 2003 Note: All test data contained in this report is based upon following the European Normative Standards. In regard to the IEC61000-4XX series of normative references, Aegis Labs followed the latest equivalent EN61000-4-X harmonized standards.

Date of cessation of presumption of conformity of the superseded standard 01/04/2004. Generally the date of cessation of presumption of conformity will be the date of withdrawal (dow), set by the European Standards body, but attention of users of these standards is drawn to the fact that in certain exceptional cases this can be otherwise. Also note that this standard incorporates by dated or undated reference, provisions from other publications. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. 7 Date of cessation of presumption of conformity of the superseded standard 01/05/04. The normative documents contain provisions, which through reference in this text, constitute provisions of this International Standard. It is recommended by CISPR that parties to agreements based upon this International Standard are encouraged to investigate the possibility of applying the most recent editions of the IEC normative documents indicated in the above passage.
Page 6 of 38 Report Number: LANTR-060108CE Revision Number: A3

2.0

SUMMARY OF TEST DOCUMENTS


Index Standard Test Limits / Levels Power Line Conducted Emissions 0.15 MHz. 0.5 MHz. (79.0 dBuV (QP)) 0.15 MHz. 0.5 MHz. (66.0 dBuV (AVG)) 0.5 MHz. 30.0 MHz. (73.0 dBuV (QP)) 0.5 MHz. 30.0 MHz. (60.0 dBuV (AVG)) EN55022: 1998+ A1: 2000 + A2: 2003
(Class A Device Limits)

Results

PASSED

Telecommunication Conducted Emissions Voltage Limits 0.15 MHz. 0.5 MHz. (97.0 87.0 dBuV (QP)) 0.15 MHz. 0.5 MHz. (84.0 74.0 dBuV (AVG)) 0.5 MHz. 30.0 MHz. (87.0 dBuV (QP)) 0.5 MHz. 30.0 MHz. (74.0 dBuV (AVG)) Radiated Emissions (Rx Antenna 10m distance) 30.0 MHz. 230.0 MHz. (40.0 dBuV (QP)) 230.0 MHz. 1000.0 MHz. (47.0 dBuV (QP)) IEC 61000-4-2: 1995 +A1: 1998 +A2: 2000 Max 8 kV Air Discharge Max 4 kV Contact Discharge IEC 61000-4-3: 2002 80 MHz - 1000 MHz, 3 V/m (unmodulated, R.M.S), 80% AM (1 kHz) IEC 61000-4-4: 1995 + A1: 2000 + A2: 2001 1.0 kV Power Lines 0.5 kV I/O Lines

PASSED

PASSED

PASSED

PASSED

PASSED

EN55024: 1998+ A1: 2001 +A2: 2003 Section 4.0

IEC 61000-4-5: 1995 + A1: 2000 1.0 kV Line to Line (1.2/50) AC Mains 2.0 kV Line to Ground (1.2/50) AC Mains IEC 61000-4-6: 1996 + A1: 2000 0.15 MHz 80 MHz, 3 V (unmodulated, R.M.S), 80% AM (1 kHz) AC Mains and Telecommunications Port IEC 61000-4-8: 1993 + A1: 2000 50 Hz, 1 A/m (rms) IEC 61000-4-11: 1994 + A1: 2000 Voltage Dips - <95% reduction for 0.5 periods 30% reduction for 25 periods Voltage Interruptions - <95% reduction for 250 periods

PASSED

PASSED PASSED

PASSED

Page 7 of 38 Report Number: LANTR-060108CE Revision Number: A3

2.0

SUMMARY OF TEST DOCUMENTS (Continued)


Index Standard Test Limits / Levels For Class A equipment the EUT maximum permissible harmonic current per watt (mA/W) shall not exceed. Odd Harmonics: n=3, Max mA/W=2.30 n=5, Max mA/W=1.14 n=7, Max mA/W=0.77 n=9, Max mA/W=0.40 n=11, Max mA/W=0.33 n=13, Max mA/W=0.21 15</= n </=39, Max mA/W=0.15,15/n For Class A equipment the EUT maximum permissible harmonics of the input current shall not exceed: Even Harmonics: n=2, Max A=1.08 n=4, Max A=0.43 n=6, Max A=0.30 8</= n </=40, Max A=0.23, 8/n The following limits apply: The value of Pst shall not be greater than 1.0 The value of Plt shall not be greater than 0.65 The value of d(t) during a voltage change shall not exceed 3.3% for more than 500ms. The relative steady state voltage change, dc, shall not exceed 3.3% The maximum relative voltage change dmax shall not exceed 4%, 6% or 7% depending on equipment type Results

PASSED

EN61000-3-2: 2000
(Class A Device Limits)

PASSED

EN61000-3-3: 1995 +A1: 2001

PASSED

Page 8 of 38 Report Number: LANTR-060108CE Revision Number: A3

2.0

SUMMARY OF TEST DOCUMENTS (Continued)

Conducted Emissions 6 Highest Measurements (Group West Power Supply) 6 Highest AC Conducted Emissions Data
Frequency Measured (MHz) 0.8200 1.0900 0.8200 1.1100 0.5500 0.5500 Meter Reading (dBuV) 59.97 59.81 59.69 59.64 59.55 59.19 Detector Function (PK/QP/AV) PK PK PK PK PK PK Average Limit (dBuV) 60.00 60.00 60.00 60.00 60.00 60.00 Average Delta (dB) -0.03 -0.19 -0.31 -0.36 -0.45 -0.81 QuasiPeak Limit (dBuV) 73.00 73.00 73.00 73.00 73.00 73.00 QuasiPeak Delta (dB) -13.03 -13.19 -13.31 -13.36 -13.45 -13.81 Line L2 L2 L1 L1 L2 L1 Voltage / Freq. 230 / 50 230 / 50 230 / 50 230 / 50 230 / 50 230 / 50

Radiated Emissions 6 Highest Measurements (Group West Power Supply) 6 Highest Radiated Emissions Data
Freq. (MHz) Meter Reading (dBuV) Antenna Height (cm) Azimuth (degrees) Quasi pk or AVG (dBuV) Cable Factor (dB) Antenna Factor (dB) Corrected Reading (dBuV/m) Limits (dBuV/m) Diff (dB) +=FAIL Polarity

375.00 229.99 750.00 336.01 110.67 750.00

18.64 8.35 8.27 15.99 13.42 6.95

375 100 400 375 100 100

270 225 315 270 315 135

3.10 2.49 4.43 2.94 1.79 4.43

15.10 17.52 22.00 15.36 12.08 22.00

36.84 28.36 34.70 34.29 27.29 33.38

47.00 40.00 47.00 47.00 40.00 47.00

-10.16 -11.64 -12.30 -12.71 -12.71 -13.62

H V H H V V

Page 9 of 38 Report Number: LANTR-060108CE Revision Number: A3

2.0

Summary of Regulatory Limits (Continued)

Conducted Emissions 6 Highest Measurements (CUI Power Supply) 6 Highest AC Conducted Emissions Data
Frequency Measured (MHz) 0.4200 22.8200 18.0800 22.8200 0.4000 22.8200 Meter Reading (dBuV) 41.74 35.14 34.95 34.82 40.79 34.39 Detector Function (PK/QP/AV) PK PK PK PK PK PK Average Limit (dBuV) 66.00 60.00 60.00 60.00 66.00 60.00 Average Delta (dB) -24.26 -24.86 -25.05 -25.18 -25.21 -25.61 QuasiPeak Limit (dBuV) 79.00 73.00 73.00 73.00 79.00 73.00 QuasiPeak Delta (dB) -37.26 -37.86 -38.05 -38.18 -38.21 -38.61 Line L2 L2 L1 L1 L2 L2 Voltage / Freq. 120 / 60 100 / 60 120 / 60 230 / 50 100 / 60 230 / 50

Radiated Emissions 6 Highest Measurements (CUI Power Supply) 6 Highest Radiated Emissions Data
Freq. (MHz) Meter Reading (dBuV) Antenna Height (cm) Azimuth (degrees) Quasi pk or AVG (dBuV) Cable Factor (dB) Antenna Factor (dB) Corrected Reading (dBuV/m) Limits (dBuV/m) Diff (dB) +=FAIL Polarity

375.00 336.01 110.77 750.00 375.00 288.00

18.76 15.99 14.07 5.30 12.81 8.14

300 300 400 100 100 300

270 0 0 180 0 90

3.10 2.94 1.79 4.43 3.10 2.70

15.10 15.36 10.65 22.00 15.30 20.17

36.96 34.29 26.51 31.73 31.21 31.01

47.00 47.00 40.00 47.00 47.00 47.00

-10.04 -12.71 -13.49 -15.27 -15.79 -15.99

H H H V V H

Page 10 of 38 Report Number: LANTR-060108CE Revision Number: A3

3.0

DEFINITIONS

Digital device: An unintentional radiator (device or system) that uses digital techniques and generates and uses timing signals or pulses at a rate in excess of 9000 pulses (cycles) per second; inclusive of telephone equipment that uses digital techniques or any device or system that generates and uses RF energy for the purpose of performing data processing functions, such as electronic computations, operations, transformations, recording, filing, sorting, storage, retrieval, or transfer (FCC 47CFG Part 15). Electromagnetic disturbance: Any electromagnetic phenomena that may degrade the performance of a device, piece of equipment, or system, or adversely affect living or inert matter. Equipment under test: A device or system being evaluated for compliance that is representative of a product to be marketed. Host: A device to which other devices (peripherals) are connected and that generally controls those devices. Incidental radiator: A device that produces RF energy during the course of its operation, although the device is not intentionally designed to generate or emit RF energy. Examples of incidental radiators are dc motors, mechanical light switches and so on. Normalized site attenuation: Site attenuation divided by the antenna factors of the radiating and receiving antennas (all in linear units) Reference ground plane: A conducting flat surface or plate that is used as a common reference point for circuit returns and electric or signal potentials and that reflects electromagnetic waves. Tabletop device: A device designed to be placed and normally operated on the raised surface of a table, e.g., most personal computers. Unintentional radiator: A device that generates RF energy for use within the device, or that sends RF signals by conduction to associated equipment via connecting wiring, but which is not intended to emit RF energy by radiation or induction. (FCC 47CFR Part 15).

Circuit power factor: the circuit power factor is the ratio of the measured active input power to the product of the supply voltage (r.m.s.) and the supply current (r.m.s.) Active power: the mean value, taken over one period, of the instantaneous power. Note: the active input power is the active power measured at the input supply terminals of the equipment under test. Total harmonic current: the total r.m.s. value of the harmonic current components of orders 2 to 40. Partial odd harmonic current: the total r.m.s. value of the odd harmonic current components of orders 21 to 39. Voltage fluctuation: series of changes of r.m.s. voltage evaluated as a single value for each successive half-period between zero crossing of the source voltage. Flicker: impression of unsteadiness of visual sensation induced by a light stimulus whose luminance or spectral distribution fluctuates with time. r.m.s. Voltage shape: the time function of the r.m.s. voltage, evaluated as a single value for each successive half period between zero-crossings or the source voltage

Refer to IEC 60050(161):1990 for additional definitions and vocabulary concerning Electro-magnetic Compatibility
Page 11 of 38 Report Number: LANTR-060108CE Revision Number: A3

3.0

DEFINITIONS (Continued)

degradation: The unwanted change in operational performance of an EUT due to electromagnetic disturbances. This does not necessarily mean malfunction or catastrophic failure. port: particular interface of the specified equipment with the external electromagnetic environment. May include one or more of the following inputs: AC/DC power, earth port, signal port and/or telecommunication port. Voltage change characteristic: the time function of the r.m.s. voltage change evaluated as a single value for each successive half period between zero-crossings of the source voltage between time intervals in which the voltage is in a steady-state condition for at least 1 s. Flickermeter: an instrument designed to measure any quantity representative of flicker. Note: measurements are normally Pst and Plt. equipment under test: a representative ITE or functionally interactive group of ITE (that is a system), which includes one or more host units and is used for evaluation purposes normative: Annexes designated normative are part of the body of the standard. In this standard, Annex ZA is normative. degradation: the unwanted change in operational performance of an EUT due to electromagnetic disturbances this does not necessarily mean malfunction or catastrophic failure. multifunction equipment: information technology equipment in which two or more functions subject to this standard and/or to other standards are provided in the same unit.

Refer to IEC 60050(161):1990 for additional definitions and vocabulary concerning Electro-magnetic Compatibility
Page 12 of 38 Report Number: LANTR-060108CE Revision Number: A3

4.0

APPROVAL SIGNATURES

TEST & REPORT SIGNATORIES: Test Performed By: Report Approved By: 02/10/06 Date

_____ Ralph Jimenez Test Technician Aegis Labs, Inc.

__02/02/06 Date:

Rick Candelas Lab Manager Aegis Labs, Inc.

Test and Report Completed By: _____ Powen Cheng Test Engineer Aegis Labs, Inc. __02/06/06 Date:

Report Approved By: _02/10/06 Steve J. Kuiper Date Quality Assurance Manager Aegis Labs, Inc.

Page 13 of 38 Report Number: LANTR-060108CE Revision Number: A3

5.0

ADMINISTRATIVE DATA AND TEST DESCRIPTION


ITE Type: External Device Server

DEVICE TESTED:

Model Number(s): UDS1100 Serial Number: N/A


January 22nd, 2006 January 23rd, 24th, 26th, 27th, 30th, 31st, February 1st, 2006

DATE EUT RECEIVED: TEST DATE(S):

ORIGIN OF TEST SAMPLE(S): EQUIPMENT CLASS:

Production

EUT tested as CLASS A device


Lantronix 15353 Barranca Parkway Irvine, CA 92618

RESPONSIBLE PARTY:

CLIENT CONTACT: MANUFACTURER:

Mr. Daryl Miller

Lantronix
Aegis Labs, Inc. 23091 Antonio Pkwy #310 RSM, CA 92688 Chamber #1 Aegis Labs, Inc. 32231 Trabuco Creek Road Trabuco Canyon, CA 92678 Open Area Test Site #1

TEST LOCATION:

ACCREDITATION CERTIFICATE(s): PURPOSE OF TEST:

A2LA Certificate Number: 1111.01, Valid through February 28, 2006

To demonstrate compliance with the standards as described in Sections 1.0 & 2.0 of this report. Proficiency Testing and Uncertainty Calculations for all tests indicated in this report have been conducted in accordance with ISO 17025:1999 requirements Section 5.5.4, 5.5.1 and 5.9. Uncertainty Budgets and Proficiency Test results available upon request. All accredited equipment calibrations were performed by Liberty Labs, Inc. and World Cal. with typical calibration uncertainty estimates derived from ISO Guide to the determination of uncertainties with a Coverage Factor of k=2 for 95% level of confidence.

UNCERTAINTY BUDGET:

STATEMENT OF CALIBRATION:

Page 14 of 38 Report Number: LANTR-060108CE Revision Number: A3

6.0 6.1

DESCRIPTION OF EUT CONFIGURATION Arrangement and Location of EUT and Host Equipment

To 12VDC Power Adapter

Ethernet Port

EUT
Ethernet Cable
Serial Port

Computer

Se ria

lC

ab le

Monitor

Keyboard

Mouse

Page 15 of 38 Report Number: LANTR-060108CE Revision Number: A3

6.2

EUT Description and Configuration

Equipment Under Test (EUT): External Device Server


Test Routine Software Programs used during testing of EUT and Peripherals: Number of External Test Ports Exercised: Power Supply Voltage applied to EUT during qualification measurements: Clocks and/or Crystal Oscillator(s): 6.2.1 Product Description Lantronix Test Software 1 Serial (Exercised) 1 Ethernet (Exercised)
Conducted Emissions: 230VAC / 50 Hz Radiated Emissions: 230VAC / 50 Hz Harmonic & Flicker: 230 VAC / 50Hz Immunity: 230VAC / 50 Hz

25 MHz

The UDS1100 external device server can remotely monitor, manage and share connected devices over a network or the Internet. It lets you replace limited distance, point-to-point serial connections. Using a method called serial tunneling; the EUT encapsulates serial data into packets and transports it over 10BaseT/100Base-TX Ethernet. The EUT can also be set up locally through its serial port, or remotely over a network using Telnet or a web browser.

Page 16 of 38 Report Number: LANTR-060108CE Revision Number: A3

6.2.2 EUT Configuration The EUT (External Device Server, Model Number: UDS1100) and host peripherals were operated according to Section 6.1 of this report. For all tests performed, the EUT had devices connected to all its external ports. In addition, all appropriate test ports were exercised to simulate, as closely as possible, the end user environment. The EUT was tested in three different configurations: Configuration 1: The EUT was configured to receive power from a 12VDC Group West Power Adapter. The EUTs DB-25 type serial port and Ethernet port were connected to the host computers DB-9 type serial and Ethernet ports through serial cable with a DB-25 to DB-9 converter and Ethernet cables. The Dell computer was then connected to a Dell monitor, Dell keyboard, and Microsoft mouse via its video, keyboard, and mouse ports respectively. In this configuration the EUT was sending and receiving data packet from the Dell computer via its Ethernet and serial ports. Full testing was performed for this configuration and can be found in Appendix A. Configuration 2: In this configuration the EUT was receiving power from a 12VDC CUI Power Adapter. All the other connections and operations were the same as configuration 1. Partial testing was performed for this configuration and can be found in Appendix B.

Page 17 of 38 Report Number: LANTR-060108CE Revision Number: A3

6.3

List of EUT, Sub-Assemblies, and Host Equipment

Equipment Under Test


Manufacturer Lantronix, Inc. Sub-assemblies Group West CUI, Inc. Equipment Name External Device Server Power Adapter Power Adapter Model or Part Number UDS1100 TRC-12-0830 3A-161WP12 Serial Number N/A N/A N/A

Host Equipment
Manufacturer
Computer System

Equipment Name

Model or Part Number MMS M780 SK-1000REW Intellimouse 1.2A PS/2 Compatible

Serial Number

DELL DELL DELL Microsoft

Computer Monitor Keyboard Mouse

4ZFAW 5322DE78XR89 12710-8AC-1500 4005705-9

Page 18 of 38 Report Number: LANTR-060108CE Revision Number: A3

6.4

I/O Cabling Diagram and Description

To 12VDC Power Adapter

Ethernet Port

EUT
Serial Port

Computer
4 5

Se ria l

Ca

bl e

Ethernet Cable

Monitor

Keyboard

Mouse

Page 19 of 38 Report Number: LANTR-060108CE Revision Number: A3

6.4

I/O Cabling Diagram and Description (Continued)

The following cables were attached to the EUT during all testing. Cable Grouping 1:

These are 3m braid and foil shielded round cables connecting the EUTs serial ports to the host computer. The EUTs metallic DB-25 type serial port was connected to a DB-25 to DB-9 converter then connected to the host DELL computer by a DB-9 serial cable at both end.

Cable 2:

This is a 10m unshielded Ethernet cable connecting the EUTs Ethernet port to the host computer. It has a plastic RJ-45 type connector at both ends.

Cable 3:

These are 5-foot braid and foil round shielded cable connecting the Computers to the Monitors. The cables have metallic DB-15 connector at the computer end and are hardwired into the monitor. The shield of the cables is grounded to the chassis via the connector shell. These are 1-meter foil shielded round cables connecting the Computers to the Keyboards. The cables have metallic 8-pin Mini-Din connector at the computer end and are hardwired into the keyboard. The shield of the cable is grounded to the chassis via the connector shell. These are 1-meter foil shielded round cables connecting the Computers to the Mice. The cables have metallic 8-pin Mini-Din connector at the computer end and are hardwired into the mice. The shield of the cable is grounded to the chassis via the connector shell.

Cable 4:

Cable 5:

Page 20 of 38 Report Number: LANTR-060108CE Revision Number: A3

6.5

List of Accessory / Host Equipment Power Cables

MAXIMUM POWER CABLE CONFIGURATION OF EUT AND ACCESSORY / HOST EQUIPMENT


Power Cable FROM Equipment to PO or PS CABLE DESCRIPTION
LENGTH (m)

SHIELDED? FERRITE? LOCATION?

PO/PS: Abbreviation for Power Outlet or Power Strip (PO/PS)

EUT
Computer Monitor

Generic, bundled to 1 meter for conducted testing only Generic Generic

1.5 1.5 1.5

None None None

Page 21 of 38 Report Number: LANTR-060108CE Revision Number: A3

6.6

EMC Test Hardware and Software Measurement Equipment

TEST EQUIPMENT LIST - Emissions


Equipment Name Manufacturer Asset Number Serial Number Calibration Due Date Maintenance Calibration Cycle 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year

EMI Receiver - RF Section EMI Receiver - RF Filter Section 10dB Attenuator LISN (EUT) LISN (Access)
ISN Antenna - Biconical Antenna - Log Periodic Spectrum Analyzer Antenna - Horn Amplifier Temperature / Humidity Monitor

Hewlett Packard Hewlett Packard Radiall Solar Electronics Solar Electronics


Fischer Custom Communications EMCO EMCO Agilent ETS Miteq Dickson

A322 A349 A336 A001 A002


None

3704A00399 3737A00407 Lot 9624 961025 961024


20220 3383 00047943

09/02/06 09/02/06 07/09/06 04/01/06 07/05/06


07/18/06 03/18/06 05/23/06

A206 None A341


None None

4046A00387 57423 815980


7255185

08/15/06 12/21/06 07/21/06


N/A

1 Year 1 Year 1 Year


N/A

A012

Page 22 of 38 Report Number: LANTR-060108CE Revision Number: A3

6.6

EMC Test Hardware and Software Measurement Equipment (Continued)

TEST EQUIPMENT LIST- Immunity


Equipment Name Manufacturer Asset Number A333 A334 A294 Serial Number Calibration Due Date 01/11/07 01/11/07 01/11/07 Maintenance Calibration Cycle 1 Year 1 Year 1 Year 1 Year 1 Year N/A 1 Year N/A 1 Year N/A N/A N/A 1 Year 1 Year 1 Year 1 Year 1 Year N/A N/A 1 Year N/A

Power Analyzer & Flicker Meter Precision Impedance Source


AC Power Source

Keytek Keytek
Pacific Power

04800202 A0202344 143132 0102381


0505227

Immunity Test Generator


External 80% PQF Tap

Keytek
KeyTek

A296
A359

06/28/06
06/28/06

Capacitive Clamp Electrostatic Discharge Simulator Magnetic Field Immunity Loop RF Signal Generator Antenna Bilog RF Amplifier 1MHz-1000MHz RF Amplifier 10 kHz-220MHz Bulk Current Injection Probe Coupling / Decoupling Network
EM Injection Clamp

Keytek
Schaffner Fischer Custom Communications, Inc.

A026 A354 A198 A013 A084 A078 A077 A124 A258


A361

9706338 464 9853 9809906 2568 25374 25427 124 01052


486

NCR 09/07/06 NCR 05/09/06 NCR NCR NCR 05/05/07 03/16/07


12/05/06

Giga-Tronics Schaffner Amplifier Research Amplifier Research


Fischer Custom Communications, Inc. Fischer Custom Communications, Inc.

Fischer Custom Communications, Inc. Agilent Agilent Amplifier Research Amplifier Research Amplifier Research Schaffner

Power Meter Power Sensor Directional Coupler Directional Coupler Isotropic Probe Immunity Software

A338 A339 A079 A080 A357 A351

GB4020764 6 US39211209 25390 25315 310921 Not Available

07/07/06 07/06/06 NCR NCR 04/25/06 NCR

Page 23 of 38 Report Number: LANTR-060108CE Revision Number: A3

6.7 6.7.1

Operating Modes Emissions and Immunity

The EUT was configured in a mode consistent with its operation by the end-user. The EUT (External Device Server, Model Number: UDS1100) was exercised continuously by a test program provided by Lantronix, which exercised all the appropriate ports. The EUT operated continuously during all facets of testing. All measurements and or levels were recorded using the following software and peripherals as follows: I/O PORT(S) / ACCESSORY EQUIPMENT EXERCISED DURING TESTING Peripherals or Components EUT Serial Port EUT Ethernet Port Computer Monitor Keyboard Mouse Lantronix Software
10

Passive

11

Active

For the purposes of this report, ACTIVE refers to any device or component that will receive, transmit or pass through data without the need for the user to manually activate the device. 11 For the purpose of this report, PASSIVE refers to any device tested that is idle of any data transmission and functions primarily as dummy termination.
Page 24 of 38 Report Number: LANTR-060108CE Revision Number: A3

10

6.8

HARMONIC / FLICKER REQUIREMENTS

The test requirements for the EUT as described within this report were conducted in a well-defined and reproducible manner. A description of the test, the AC Source, Impedance Source and Flickermeter design parameters, test methods and test set-up are stipulated in the IEC / EN Standards. As such, all testing was performed to those standards listed in Section 2.0 of this report. Harmonic and Flicker testing shall be performed on the EUTs power supply according to the appropriate IEC/EN standard.

Page 25 of 38 Report Number: LANTR-060108CE Revision Number: A3

7.0 7.1

TEST EQUIPMENT SETTINGS AND FUNCTIONS (RF Emissions) Test Equipment State of the Instrument for Conducted Emission Measurements

Conducted Test: SITE #1 & #2: The Agilent EMI 8546A Receiver Series is a high-performance test receiver especially designed for making commercial EMI (Electro-Magnetic Interference) measurements. It fully conforms to the receiver standards described in CISPR (Comite International Special Des Perturbations Radioelectriques) Publication 16, C.I.S.P.R. Specification for Radio Interference Measuring Apparatus and Measurement Methods. This type of receiver is used for making measurements according to various governmental standards, such as FCC, EN and VCCI regulations. The HP 8546A tunes from 9kHz. To 6.5 GHz. making it suitable for testing a wide variety of products including but not limited to intentional and unintentional radiators.

HP 8546A Standard Test Configurations MENU LABEL Start/Stop Frequency 9 kHz-150 kHz 150 kHz 30 MHz 30 MHz 300 MHz 200 MHz 1 GHz. IF Bandwidth 200 Hz. CISPR 9 kHz CISPR 120 kHz CISPR 120 kHz CISPR Averaging Bandwidth 300 Hz 30 kHz 300 kHz 300 kHz Reference Level 70 dBuV 75 dBuV 80 dBuV 80 dBuV

Page 26 of 38 Report Number: LANTR-060108CE Revision Number: A3

7.1

Test Equipment State of the Instrument for Conducted Emission Measurements (Continued)

User-defined test parameters based upon the previous table were loaded into the instrument for prequalification and qualification testing. The peak, quasi-peak and/or average detector were used according to Section 7.2. For testing performed between 150 kHz and 30 MHz. the EMI Receiver performed a swept frequency measurement with the following EMI Receiver settings: Function REF OFFST REF ATTEN IF BW AVG BW SWP SPAN ACTIVE DETECTOR Setting 10.0 dB 85.0 dBuV 10 dB 9.0 kHz 30 kHz 2.49 SEC 30 MHz PK

In reference to the LISN used during testing, the 1uF capacitor in combination with the 50uH inductor is the filter that isolated the mains from the EUT. Consequently, the 50uH inductor isolated the noise generated by the EUT from the mains. The 0.1uV couples the noise generated by the EUT to the EMI Receiver. At frequencies above 150 kHz, the EUT signals are presented with a 50-ohm impedance. The purpose of using the transient limiter is to protect the input of the EMI Receiver from large transients when connected to the LISN. The transient limiter incorporates a limiter, high pass filter, and an attenuator. Lastly, a low loss 50ohm cable was connected between the transient limiter and LISN. After the swept frequency scan was performed for both Line 1 and Line 2 the six highest readings against the Limit were recorded in the data sheet along with a snapshot image of the sweep scan. Upon completion of the swept frequency scan, the six highest peaks against the reference level were remeasured in manual mode and recorded in the Microsoft Windows Excel .xls. spreadsheet. The graphical scans in Appendix A only reflect peak readings while the tabulated data sheets reflect either peak, average, and/or quasi-peak measurements. Upon completion of the swept frequency scan, the six highest peaks against the reference level were remeasured in manual mode and recorded in the Microsoft Windows Excel xls. spreadsheet. The graphical scans in the appropriate Appendix only reflect peak readings while the tabulated data sheets reflect either peak, average, and/or quasi-peak measurements.

Page 27 of 38 Report Number: LANTR-060108CE Revision Number: A3

7.2

Decision Tree for Peak Detector Measurements

PK detector

Yes PK < AVG limit ?

No Yes PK < QP limit ? QP detector No

No Yes Yes QP < AVG limit ? QP < QP limit ? No

AVG detector

Yes

No AVG < AVG limit ?

PASS

PK Peak QP Quasi-Peak AVG Average

FAIL

Page 28 of 38 Report Number: LANTR-060108CE Revision Number: A3

7.3

Test Equipment State of the Instrument for Radiated Emission Measurements

Radiated Test: (30 MHz. 1000 MHz.) SITE #1 & SITE #2: The Agilent EMI 8546A Receiver and 8568B/85460A/85685A Series Receiver(s) were independently certified to meet the CISPR-16 requirements by the German BZT (Bundesamt fur Zulassungen der Telkommunikution, the German Appeals Office for Telecommunications). Additionally the receiver characteristics were verified/calibrated by an independent third party ISO 17025 calibration laboratory. Because of the added complexity of the open-air ambient environment, which can interfere with the device under test, the receiver in conjunction with a low ambient environment facility and trained personnel were an excellent combination to ensure accurate and repeatable measurements. Specifically, to make an accurate measurement when necessary, the receiver was placed in linear mode and caution was exercised to ensure that the receiver was not in saturation at the front-end mixer because of potential large narrowband or broadband emissions. A useful overload detection scheme was employed to alert the measurement technician of any overload conditions in all frequency ranges and in all modes of receiver operation. The advanced overload detection and measurement scheme were autoranged or automatically put in enough attenuation prior to the first mixer to measure the signal in non-overload conditions. However, the ambient noise floor level of the Aegis Labs Open Area Test Sites (OATS) is substantially lower than most thereby requiring little attention to be paid to the overload condition. The receiving (Rx) antenna(s) was placed 10m from the nearest side of the EUT facing the Rx antenna. The EUT (if floor-standing) was placed directly on the flush-mounted 360 degree rotating turntable. The EUT (if table-top) was placed directly on an 80cm high non-metallic table, and the table was placed on the rotating turntable. During the initial EMI scan, all the suspect frequencies, i.e.; harmonics, broadband signals were checked with the Rx broadband antennas in both vertical and horizontal polarities. The biconical Rx and log periodic Rx antennas were used from 30 MHz. 299.99 MHz. and from 300 MHz. 999.99 MHz. Upon completion of all harmonic and broadband measurements, the balance of any remaining frequencies was checked between 30 MHz. 999.99 MHz. Any signals appearing within 20 dB of the classification limit A or B were measured. Each signal was maximized by first rotating the turntable at least 360 degrees and recording the azimuth in the data sheet. Lastly, the Rx antenna was raised and/or lowered to maximize the signal elevation. If the measured signal was obtained using the peak detector and that signal appeared within 3 dB of the regulatory limit line, then the same signal was re-measured using the quasi-peak detector on the EMI receiver. Both meter readings if necessary were recorded on the data sheet. In the case of measuring around ambient signals several methods were employed to ensure accuracy including but not limited to using the Signal Substitution Method with the Rx antenna placed at 3m from the EUT, the Marker Delta Method or a Logarithmic Calculation Method for either broadband or narrowband signals.

Page 29 of 38 Report Number: LANTR-060108CE Revision Number: A3

7.4

Conducted Emissions Test Setup

The Equipment Under Test (EUT) shall be configured as a system with peripherals connected, so that at least one interface port of each type is connected to one external peripheral when tested for conducted emissions according to ANSI C63.4-2003. The EUT shall have a minimum of at least one test configuration identified on the Engineering Data Sheets of said report. These are either in a tabletop setup as shown on following page or in a freestanding configuration as required for floor-standing systems. The test data shall be collected using the appropriate EMI Receiver System as described in Section 7.1. The Conducted Test for tabletop configurations shall be performed on 2 each galvanized sheets measuring 10mm thickness X 8.0 FT.X 10.0 FT. situated in a vertical and horizontal position diagramed in Section 7.5 of this report. The horizontal-conducting plane extends at least 1.5 meters beyond the all four sides of the EUT. For tabletop equipment, a non-metallic table rests on top of the ground plane extending 40 cm from and parallel to the vertical plane. The EUT shall be powered through an appropriate Line Impedance Stabilization Network (LISN), bonded to the ground plane as described in ANSI C63.4-2003. The LISN power shall be isolated from other filtered power via an additional filter to ensure that RFI from the auxiliary instrumentation or support equipment does not influence the readings obtained. The power input cables to the LISN and the EMI equipment shall be arranged so that they will not influence the measurement results. Any excess power cord shall be folded back and forth to form a 30-cm non-inductive bundle. When applicable the telecom port of the EUT shall be connected to the accessory equipment via a two balanced telecom pairs ISN, which is bonded to the horizontal ground plane as described in CISPR22. The Automated Aegis/LabView Software (ALVS) measurement system was located outside the sphere during the test.

Page 30 of 38 Report Number: LANTR-060108CE Revision Number: A3

7.5

Conducted Emissions Site Diagram

Page 31 of 38 Report Number: LANTR-060108CE Revision Number: A3

7.6

Radiated Emissions Test Setup

The Open Area Test Sites (OATS) shall be used for radiated emission testing. These test sites are designed according to ANSI C63.4-2003 and ANSI C63.7-1992 guidelines. The OATS facilities are periodically tested using a calibrated field site source with the resultant test data compiled into a statistical data based used to check the integrity of the test site measurements. The Measurement procedure shall be in accordance with ANSI C63.4-2003 and ANSI C63.7-1992 requirements. The EUT shall be placed in the prescribed spot of the OATS, (either atop the turntable, or atop the ground plane) where applicable. The following page refers to the setup depicting a typical test configuration; exact EUT set-up is detailed in the Engineering Data Sheets. The turntable shall rotate a minimum of 360 deg. to obtain the highest emissions. During rotation the antenna (s), supported by the mast array shall also be raised and lowered at the test personnels discretion to identify the maximum energy lobe. See diagram on following page for graphical representation. For short and permanently connected conductors who cannot be extended by the user with commercially available cables, the EUT shall be tested only with the manufacturers furnished cables.

Page 32 of 38 Report Number: LANTR-060108CE Revision Number: A3

7.7

Radiated Emissions Site Diagram - Side View and Plan View

Page 33 of 38 Report Number: LANTR-060108CE Revision Number: A3

7.7

Radiated Emissions Site Diagram Side View and Plan View (Continued)

Note: Aegis Labs Open Area Test Sites exceed the 2 R Frensel Ellipse measurement zone as defined under ANSI C63.4: 2003 to minimize possible reflection issues from surrounding structures.

Page 34 of 38 Report Number: LANTR-060108CE Revision Number: A3

8.0

SAMPLE CALCULATIONS

If a preamplifier is used during the Radiated Emissions Testing, it is required that the amplifier gain be subtracted from the Spectrum Analyzer (Meter) Reading. In addition, a correction factor for the antenna, cable and a distance factor, if any, must be applied to the Meter Reading before a true field strength reading can be obtained. In the Automatic Mode of A.R.M.S. measurements, these considerations are automatically presented as a part of the printout. In the case of manual measurements and for greater efficiency and convenience, usage of the calibration correction factors in the Appendices is necessary to calculate the Corrected Meter Reading. These correlation factors for each meter reading, shall be modified to reflect these correlation factors at each frequency value so that the meter readings can be compared directly to the modified specification limit. This modified specification limit is referred to as the Corrected Meter Reading Limit (CML). The equation shall be derived in the following manner: Corrected Meter Reading = Meter Reading + F +C G - D Where, F = Antenna Factor C = Cable Factor G = Amplifier Gain D = Distance Factor Therefore, the equation for determining the Corrected Meter Reading Limit (CML) is: CML = Specification Limit - F - C + G + D For the manual mode of measurement, a table of corrected meter reading limits shall be used to permit immediate comparison of the meter reading to determine if the measured emission amplitude exceeded the specification limit at that specific frequency. There shall be two calculation sheets done, one for three meter and one for ten-meter measurement distances, where applicable. The correction factors for the antenna and the amplifier gain are attached in the Appendices.

Page 35 of 38 Report Number: LANTR-060108CE Revision Number: A3

9.0 9.1

IMMUNITY TEST REQUIREMENTS GENERAL The immunity test requirements for the equipment under test as described within this report were conducted in a well-defined and reproducible manner. A description of the test, the test generator design parameters, test methods and test set-up are stipulated in the IEC / EN standards. As such, all testing was performed in accordance with the standards listed in Section 1.0 of this report. Static electricity discharges shall be applied to those points and surfaces of the EUT, which are expected to be touched during usual operation, including user access, as specified by the manufacturer. Electrical fast transient tests shall be conducted on the power supply and signal ports. When necessary, for equipment containing identical ports, only one shall be tested. Interface ports, which are intended by the manufacturer to be connected to data cables not longer than 3m shall not be tested. Continuous radio frequency disturbance testing shall be performed and the manufacturer shall configure the EUT in such a manner that the dwell time set at each frequency not to be less than the time necessary for the EUT to be exercised and to be able to respond. Additionally, the dwell time shall not exceed 5 s at each of the frequencies during the scan. Continuous conducted disturbance shall be performed on the EUTs power supply and signal cables in accordance with appropriate IEC/EN standard. Power frequency magnetic field testing shall be conducted with the EUT placed in the center of the H-coil system (immersion method). The cables supplied by the manufacturer shall be used. Surge testing shall be performed on the EUTs power supply according to the appropriate IEC/EN standard. Voltage dips and interrupts shall be applied to the EUT, and there shall be no deviation from the appropriate IEC/EN standard used for this test.

Page 36 of 38 Report Number: LANTR-060108CE Revision Number: A3

9.2

PERFORMANCE CRITERIA

TEST
Electrostatic Discharge

PERFORMANCE CRITERIA
B

Radio-Frequency Electromagnetic Field

Electrical Fast Transients

High Energy Transients

Radio Frequency Conducted Susceptibility

Power Frequency Magnetic Field Voltage Dips Voltage Interrupts

A B - >95% reduction for 0.5 periods & C 30% reduction for 25 periods C - > 95% reduction for 250 periods

Page 37 of 38 Report Number: LANTR-060108CE Revision Number: A3

9.2

Performance Criteria (Continued)

The manufacturer has the obligation to express the performance criteria in terms, which relate to the performance of his specific product when used as intended. The following performance criteria are applicable, and shall only be evaluated when the functions referred to are implemented. Performance Criterion A The equipment shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user may reasonably expect from the equipment if used as intended. Performance Criterion B After the test, the equipment shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed after the application of the phenomena below a performance level specified by the manufacturer, when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance. Performance Criterion C Loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of the controls by the user in accordance with the manufacturers instructions. Functions, and/or information stored in non-volatile memory, or protected by a battery backup, shall not be lost.

Page 38 of 38 Report Number: LANTR-060108CE Revision Number: A3

APPENDIX A

TEST DATA

EUT Configuration #1 Model Number Serial Number Power Supply UDS-1100 N/A Manufacturer: Group West Model Number: TRC-12-0830 Serial Number: N/A

Page 1 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

CONDUCTED EMISSIONS TEST RESULTS


CLIENT: EUT: MODEL NUMBER: SERIAL NUMBER: CONFIGURATION:
Lantronix External Device Server UDS1100 N/A 230 VAC / 50Hz DATE: PROJECT NUMBER: TEST ENGINEER: SITE #: TEMPERATURE: HUMIDITY: TIME: 01/24/06 LANTR-060108 RJ 1 21 deg. C 13% 10:40 AM

Description: Results:

Conducted Power RF Emissions (150 kHz 30 MHz) PASSED LINE 1 and LINE 2 Class A Limits

Page 2 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Conducted Emissions Test Results (Continued) 230VAC/50Hz (LANTR-060108-08) CISPR22 CLASS A CONDUCTED EMISSIONS LINE 1
Freq. (MHz) 0.2700 0.5500 0.5500 0.8200 0.8200 1.1100 1.1100 1.3800 2.4600 Meter Reading (dBuV) 60.70 59.19 58.54 59.69 50.89 59.64 56.18 56.46 52.03 Detector (PK/QP/AV) PK PK AV PK AV PK AV PK PK Average Limit (dBuV) 66.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 Average Delta(dB) -5.30 -0.81 -1.46 -0.31 -9.11 -0.36 -3.82 -3.54 -7.97 Quasi-Peak Limit (dBuV) 79.00 73.00 73.00 73.00 73.00 73.00 73.00 73.00 73.00 Quasi-Peak Delta(dB) -18.30 -13.81 -14.46 -13.31 -22.11 -13.36 -16.82 -16.54 -20.97

Page 3 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Conducted Emissions Test Results (Continued) 230VAC/50Hz (LANTR-060108-08) CISPR 22 CLASS A CONDUCTED EMISSIONS - LINE 2
Freq. (MHz) 0.2700 0.5500 0.5500 0.8200 0.8200 1.0900 1.0900 1.3800 2.7500 Meter Reading (dBuV) 60.80 59.55 58.92 59.97 50.79 59.81 37.82 56.27 52.92 Detector (PK/QP/AV) PK PK AVG PK AVG PK AVG PK PK Average Limit (dBuV) 66.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 Average Delta(dB) -5.20 -0.45 -1.08 -0.03 -9.21 -0.19 -22.18 -3.73 -7.08 Quasi-Peak Limit (dBuV) 79.00 73.00 73.00 73.00 73.00 73.00 73.00 73.00 73.00 Quasi-Peak Delta(dB) -18.20 -13.45 -14.08 -13.03 -22.21 -13.19 -35.18 -16.73 -20.08

Page 4 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

CONDUCTED EMISSIONS TEST RESULTS


CLIENT: EUT: MODEL NUMBER: SERIAL NUMBER: CONFIGURATION:
Lantronix Inc. External Device Server UDS1100 N/A 230 VAC / 50Hz

DATE: PROJECT NUMBER: TEST ENGINEER: SITE #: TEMPERATURE: HUMIDITY: TIME:

01/26/06 LANTR-060108 JC/PC 2 17 deg C 41% RH 2:30 PM

Description: Results:

Conducted Telecommunication Port Ethernet" RF Emissions (150 kHz 30 MHz) PASSED Voltage Limits

Page 5 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Conducted Emissions Test Results (Continued)


TELECOM (QUANT-060108-10) CISPR22 CLASS A CONDUCTED EMISSIONS TELECOM LINE
Freq. (MHz) Meter Reading (dBuV) Detector (PK/QP/AV) Average Limit (dBuV) Average Delta(dB) Quasi-Peak Limit (dBuV) Quasi-Peak Delta(dB)

0.82 1.11 1.38 2.4900 2.79 2.7900

62.53 65.80 64.66 61.80 62.41 62.41

PK PK PK PK PK PK

74.00 74.00 74.00 74.00 74.00 74.00

-11.47 -8.20 -9.34 -12.20 -11.59 -11.59

87.00 87.00 87.00 87.00 87.00 87.00

-24.47 -21.20 -22.34 -25.20 -24.59 -24.59

Page 6 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

RADIATED EMISSIONS TEST RESULTS


CLIENT: EUT: MODEL NUMBER: SERIAL NUMBER: CONFIGURATION: Lantronix Inc. External Device Server UDS1100 N/A 230 VAC / 50. DATE: PROJECT NUMBER: TEST ENGINEER: SITE #: TEMPERATURE: HUMIDITY: TIME: 01/23/06

LANTR-060108
RJ 1 16 deg. C 11% RH 9:55 AM

Description: Results:

Radiated RF Emissions (30 MHz 1000 MHz) PASSED Horizontal and Vertical Antenna Polarizations Class A Limits

Page 7 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Radiated Emissions Test Results (Continued) 230VAC/50Hz (LANTR-060108-01) CISPR22 CLASS A RADIATED EMISSIONS - Horizontal Antenna Polarization
Freq. (MHz) Meter Reading (dBuV) Antenna Height (cm) Azimuth (Degrees) Quasi Pk Or AVG (dBuV) Corrected Reading (dBuV/m) Limits (dBuV/m) Diff (dB) +=FAIL

66.25 110.77 130.00 150.03 240.00 244.10 246.01 260.00 288.00 300.00 336.01 375.00 400.00 423.67 445.42 450.00 750.00

9.80 11.96 8.07 7.75 11.85 10.89 6.74 6.39 8.69 8.91 15.99 18.64 7.00 4.40 3.26 3.89 8.27

400 375 400 400 400 400 400 350 400 400 375 375 375 400 375 400 400

180 270 180 135 45 315 45 135 315 315 270 270 135 45 135 225 315

20.68 24.40 21.74 22.29 31.33 30.56 26.50 27.26 31.56 25.97 34.29 36.84 26.09 23.76 23.61 24.46 34.70

40.00 40.00 40.00 40.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00

-19.32 -15.60 -18.27 -17.71 -15.67 -16.44 -20.50 -19.74 -15.44 -21.03 -12.71 -10.16 -20.91 -23.24 -23.39 -22.54 -12.30

Page 8 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Radiated Emissions Test Results (Continued)

230VAC/50Hz (LANTR-060108-01) CISPR22 CLASS A RADIATED EMISSIONS - Vertical Antenna Polarization


Freq. (MHz) Meter Reading (dBuV) Antenna Height (cm) Azimuth (Degrees) Quasi Pk Or AVG (dBuV) Corrected Reading (dBuV/m) Limits (dBuV/m) Diff (dB) +=FAIL

66.25 79.98 110.67 149.97 229.99 240.00 244.10 246.01 288.00 300.00 336.01 375.00 400.00 423.67 445.42 450.00 750.00

12.40 8.70 13.42 8.67 8.35 9.21 6.84 7.27 9.42 6.22 9.26 13.96 6.51 6.10 10.72 6.42 6.95

100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100

0 45 315 225 225 270 270 270 180 180 135 0 270 225 135 270 135

22.90 20.05 27.29 22.20 28.36 29.69 27.51 28.03 33.28 23.18 27.60 32.36 25.70 25.66 31.27 27.19 33.38

40.00 40.00 40.00 40.00 40.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00

-17.10 -19.95 -12.71 -17.80 -11.64 -17.31 -19.49 -18.97 -13.72 -23.82 -19.40 -14.64 -21.30 -21.34 -15.73 -19.81 -13.62

Page 9 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

HARMONIC CURRENT EMISSIONS EN61000-3-2


CLIENT: EUT: MODEL NUMBER: SERIAL NUMBER: SPECIFICATION: TEST LEVEL:
Lantronix External Device Server UDS1100

DATE: TEST ENGINEER:


BAROMETRIC PRESSURE:

01/02/06 RJ 29.84n

N/A
EN61000-3-2

TEMPERATURE: HUMIDITY: TIME:

20 deg C
50% RH 04:00 PM

Class A Device Limits

SYS61K Version 1.25 was used The measuring setup consists of a LMG95, SN 04800202, Rev. 3.108 according to the standard: EN61000-4-7:2002 Compliance was tested against EN61000-3-2:1995 limits The smoothing filter was switched on The measuring ranges 250.0 V, scaling 1.0 for voltage and 10.0 A, scaling 1.0 for current were used. Class A was chosen Measuring time was: 00:02:30 Voltage check: All voltage harmonics within the limit Voltage +/-2% of nominal value Frequency within +/-0.5% Phase 1 : ok : ok : ok

Current check: All current harmonics within the limit : ok All fluctuating harmonics within the time limit: ok Global values from chosen frame at 00:00:00 before end of measuring (informative): Phase 1 U= 230.1223 V I= 0.0426 A P= 2.9727 W PF = 0.3031 f= 49.9961 Hz

Page 10 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

HARMONIC CURRENT EMISSIONS EN61000-3-2 (Continued)


Phase 1 n Iaver fluc% Imax Iall I/Ilim,% Umax -------------------------------------------------------------------------------------------------0 0.0125 NaN 0.0128 0.0327 1 0.0207 NaN 0.0208 0.0000 230.1124 2 0.0001 0.0000 0.0001 0.0000 0.0399 3 0.0123 0.0000 0.0125 0.5415 0.1013 4 0.0001 0.0000 0.0001 0.0000 0.0148 5 0.0122 0.0000 0.0123 1.0818 0.0323 6 0.0001 0.0000 0.0001 0.0000 0.0110 7 0.0118 0.0000 0.0119 1.5504 0.0173 8 0.0001 0.0000 0.0001 0.0000 0.0076 9 0.0115 0.0000 0.0115 2.8848 0.0115 10 0.0001 0.0000 0.0001 0.0000 0.0058 11 0.0109 0.0000 0.0110 3.3206 0.0050 12 0.0001 NaN 0.0001 0.0000 0.0057 13 0.0103 0.0000 0.0104 4.9393 0.0074 14 0.0001 NaN 0.0001 0.0000 0.0043 15 0.0096 0.0000 0.0097 6.4425 0.0040 16 0.0001 NaN 0.0001 0.0000 0.0037 17 0.0089 0.0000 0.0090 6.7694 0.0059 18 0.0001 NaN 0.0001 0.0000 0.0044 19 0.0082 0.0000 0.0082 6.9437 0.0059 20 0.0001 0.0000 0.0001 0.0000 0.0031 21 0.0074 NaN 0.0074 6.9515 0.0063 22 0.0001 NaN 0.0001 0.0000 0.0031 23 0.0066 NaN 0.0066 6.7868 0.0083 24 0.0001 NaN 0.0001 0.0000 0.0025 25 0.0058 NaN 0.0059 6.5325 0.0100 26 0.0001 NaN 0.0001 0.0000 0.0028 27 0.0050 NaN 0.0051 6.1119 0.0066 28 0.0001 NaN 0.0001 0.0000 0.0024 29 0.0043 NaN 0.0044 0.0000 0.0048 30 0.0001 NaN 0.0001 0.0000 0.0028 31 0.0036 NaN 0.0037 0.0000 0.0032 32 0.0001 NaN 0.0001 0.0000 0.0019 33 0.0029 NaN 0.0030 0.0000 0.0068 34 0.0001 NaN 0.0001 0.0000 0.0020 35 0.0023 NaN 0.0024 0.0000 0.0043 36 0.0001 NaN 0.0001 0.0000 0.0040 37 0.0018 NaN 0.0019 0.0000 0.0023 38 0.0001 NaN 0.0001 0.0000 0.0018 39 0.0014 NaN 0.0015 0.0000 0.0035 40 0.0001 NaN 0.0001 0.0000 0.0017

Page 11 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

HARMONIC CURRENT EMISSIONS EN61000-3-2 (Continued)

Certification of Test Data:


Page 12 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

VOLTAGE FLUCTUATIONS AND FLICKER EN61000-3-3


CLIENT: EUT: MODEL NUMBER: SERIAL NUMBER: SPECIFICATION: TEST LEVEL:
Lantronix External Device Server UDS1100

DATE: TEST ENGINEER:


BAROMETRIC PRESSURE:

01/02/06 RJ 29.84n

6732448
EN61000-3-3

TEMPERATURE: HUMIDITY: TIME:

20 deg C
50% RH 06:10 PM

Per Annex A

SYS61K Version 1.25 was used The measuring setup consists of a LMG95, SN 04800202, Rev. 3.108 according to the standard: EN61000-4-15 Compliance was tested against EN61000-3-3+A1 limits The measuring ranges 250.0 V, scaling 1.0 for voltage and 10.0 A, scaling 1.0 for current were used. Short time : 00:01:00 Number of periods : 24 Flicker check: Phase 1 Pst always < 1.0 : ok Plt < 0.65 : ok dmax < 4.0% : ok d(t) < 3.3% for <500ms : ok dc < 3.3% : ok Values from chosen frame at 00:00:00 before end of long time interval (informative): Phase 1 Pst = 0.0000 Plt = 0.0000 dmax = 0.0418 % dc = 0.0000 % U = 230.0382 V I = 0.0409 A P = 2.9764 W PF = 0.3165 f = 49.9963 Hz

Page 13 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

VOLTAGE FLUCTUATIONS AND FLICKER EN61000-3-3 (Continued)


n Pst 1 Plt 1 n Pst 1 Plt 1 ----------------------------------------------------------------------------------------------------1 0.0000 13 0.0000 2 0.0000 14 0.0000 3 0.0000 15 0.0000 4 0.0000 16 0.0000 5 0.0000 17 0.0000 6 0.0000 18 0.0000 7 0.0000 19 0.0000 8 0.0000 20 0.0000 9 0.0000 21 0.0000 10 0.0000 22 0.0000 11 0.0000 23 0.0000 12 0.0000 24 0.0000 0.0000

Certification of Test Data:

Page 14 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Electro-static Discharge Test Results


COMPANY: EUT: MODEL TESTED: SPEC.: LEVEL: PERFORMANCE CRITERIA: LANTRONIX External Device Server UDS1100 EN 61000-4-2: A2/2001 8.0 kV Air Discharge (Direct) 4.0 kV Contact Discharge (Direct/Indirect) B DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY: 02/02/06 RJ N/A 15 deg C 30.29 in 60% RH

TABLE 1: AIR DISCHARGE (Direct) Number of discharges per test point = 25ea, +2kV, +4kV, +6kV, Direct Discharge Location (EUT) Power Connector Serial Connector Ethernet Plastic Connector (discharge to RJ-45 connector shell) + 8.0 kV X X X

+8kV.

Pass / Fail/No Discharge Pass Pass Pass

Performance Criterion B B B

TABLE 2: CONTACT DISCHARGE (Direct) Number of discharges per test point = 25ea, +2kV & +4kV. Direct Discharge Location (EUT) Left Side of EUT Right Side of EUT Bottom Side of EUT Serial Connector Shell Ethernet Connector Shell + 4.0 kV X X X X X Pass / Fail Pass Pass Pass Pass Pass Performance Criterion B B B B B

Certification of Test Data:

Page 15 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Electro-static Discharge Test Results (Continued)


COMPANY: EUT: MODEL TESTED: SPEC.: LEVEL: PERFORMANCE CRITERIA: LANTRONIX External Device Server UDS1100 EN 61000-4-2: A2/2001 8.0 kV Air Discharge (Direct) 4.0 kV Contact Discharge (Direct/Indirect) B DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY: 02/02/06 RJ N/A 15 deg C 30.29 in 61% RH

TABLE 3: CONTACT DISCHARGE (Indirect) Number of discharges per test point = 25ea. +2kV & +4kV. Indirect Discharge Location (EUT) HCP (All 4 Sides) VCP (All 4 Sides) + 4.0 kV X X Pass / Fail Pass Pass Performance Criterion B B

Certification of Test Data:

Page 16 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Radiated Susceptibility Test Results

COMPANY: EUT: MODEL TESTED: SPEC. LEVEL: PERFORMANCE CRITERIA:

LANTRONIX External Device Server UDS1100 EN 61000-4-3: A1/2003 3.0 V/m, 1 kHz AM sine wave at 80%. A

DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY:

1/31/06 RJ N/A 12 C 30.29 in 62%

TABLE 4: RADIATED IMMUNITY Frequency Range 80 1000 MHz. Front V/H X Back V/H X Left Side V/H X Right Side V/H X Pass X Fail Perform. Criteria A

Measurements were taken in a fully lined anechoic chamber at 3.0 V/m.

Certification of Test Data:


Page 17 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Electrical Fast Transient / Burst Test Results


COMPANY: EUT: MODEL TESTED: SPEC. LEVEL: PERFORMANCE CRITERIA: LANTRONIX External Device Server UDS1100 EN 61000-4-4: A2 2002 1.0 kV Power Lines 0.5 kV I/O Lines B DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY: 1/27/06 RJ N/A 17.1 deg C 30.29 in 42% RH

TABLE 5: Electrical Fast Transient Burst (Power Lines) EFT insertion point Line Neutral Protective Earth Line to Protective Earth Neutral to Protective Earth Line to Neutral Line to Neutral to Protective Earth
TEST LEVEL (kV) START VOLTAGE (kV)

+ 1.0 kV Pass X X X X X X X
STEP VOLTAGE (kV)

- 1.0 kV Fail Pass X X X X X X X


TEST DURATION (minutes)

Fail

Performance Criteria B B B B B B B

TIME BETWEEN TESTS (seconds)

1.0

0.500

0.500

1.0

60.0

TABLE 6: Electrical Fast Transient Burst (I/O Lines) EFT insertion point Ethernet Cable Serial Cable
TEST LEVEL (kV)

+ 0.5 kV Pass X X Fail Pass X X


STEP VOLTAGE (kV)

-0.5 kV Fail

Performance Criteria B B
TIME BETWEEN TESTS (seconds)

START VOLTAGE (kV)

TEST DURATION (minutes)

1.0

0.250

0.250

1.0

60.0

Certification of Test Data:


Page 18 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Surge Test Results


COMPANY: EUT: MODEL TESTED: SPEC. LEVEL: PERFORMANCE CRITERIA: LANTRONIX External Device Server UDS1100 EN 61000-4-5: A1/A2 2001 2.0 kV Common Mode 1.0 kV Differential Mode B DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY: 1/27/06 RJ N/A 17.1 deg C 30.29 in 39% RH

TABLE 7: Power Line Transients (Common Mode) Surge insertion point Line to Ground Neutral to Ground Line & Neutral to Ground
TEST LEVEL (kV)

+ 2.0 kV Pass X X X
STEP VOLTAGE (kV)

- 2.0 kV Fail Pass X X X


TEST DURATION (minutes)

Fail

Performance Criteria B B B
TIME BETWEEN TESTS (seconds)

START VOLTAGE (kV)

2.0

0.500

0.500

1.0

50.0

TABLE 8: Power Line Transients (Differential Mode) Surge insertion point Line to Neutral
TEST LEVEL (kV)

+ 1.0 kV Pass X Fail Pass X


STEP VOLTAGE (kV)

- 1.0 kV Fail

Performance Criteria B

START VOLTAGE (kV)

TEST DURATION (minutes)

TIME BETWEEN TESTS (seconds)

1.0

0.500

0.500

1.0

50.0

Certification of Test Data:


Page 19 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Conducted Immunity Test Results


COMPANY: EUT: MODEL TESTED: SPEC. LEVEL: PERFORMANCE CRITERIA: LANTRONIX External Device Server UDS1100 EN 61000-4-6: A1/A2 2001 3.0 Vrms, 80% AM Modulated (1kHz) A DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY: 02/01/06 RJ N/A 14 C N/A 60%

TABLE 9: RF Conducted Susceptibility Test Location Power line Ethernet Cable Serial Cable Frequency range 0.15 80 MHz 0.15 80 MHz 0.15 80 MHz 3.0 Vrms Pass X X X Fail Performance Criteria A A A

Certification of Test Data:


Page 20 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Magnetic Field Immunity Test Results


COMPANY: EUT: MODEL TESTED: SPEC. LEVEL: PERFORMANCE CRITERIA: LANTRONIX External Device Server UDS1100 EN 61000-4-8: 1993 50 Hz 1.0 A(rms)/m A DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY: 02/02/06 RJ N/A 12 C 30.29 in 71%

TABLE 10: Power Frequency Magnetic Field Test Frequency (Hz) 50 1.0 A(rms)/m Pass x Fail Performance Criteria A

Certification of Test Data:


Page 21 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

Voltage Dips and Interrupts Test Results

COMPANY: EUT: MODEL TESTED: SPEC. LEVEL: PERFORMANCE CRITERIA:

Lantronix External Device Server UDS1100 EN61000-4-11: A1 2002 >95%, 0.5 periods, 30%, 25 periods, >95%, 250 periods B (>95%, 0.5 periods), C (30%, 25 periods), C (>95%, 250 periods)

DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY:

1/27/06 RJ N/A 17.1 deg C 30.29 in

42% RH

Table 11: Voltage Dips and Interrupts Test (EN55024) Environmental Phenomenal Voltage Dip Voltage Dip Voltage Interruption Voltage Level 230 VAC 50Hz 230 VAC 50 Hz 230 VAC 50 Hz Reduction >95% reduction 30% reduction >95% reduction Duration 0.5 periods 25 periods 250 periods Results Pass X X X Fail Performance Criteria B C C

Certification of Test Data:


Page 22 of 22 (Appendix A) Report Number: LANTR-060108CE Revision Number: A3

APPENDIX B

TEST DATA

EUT Configuration #2 Model Number Serial Number Power Supply UDS1100 N/A Manufacture: CUI Inc. Model Number: 3A-161WP12 Serial Number: N/A

Page 1 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

CONDUCTED EMISSIONS TEST RESULTS


CLIENT: EUT: MODEL NUMBER: SERIAL NUMBER: CONFIGURATION: Lantronix External Device Server UDS100 N/A 230 VAC / 50Hz. DATE: PROJECT NUMBER: TEST ENGINEER: SITE #: TEMPERATURE: HUMIDITY: TIME: 01/23/06 LANTR-060108 RJ 1 21 deg. C 17% 04:20 PM

Description: Results:

Conducted RF Emissions (150 kHz 30 MHz) PASSED LINE 1 and LINE 2 Class A Limits

Page 2 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

Conducted Emissions Test Results (Continued) 230VAC/50Hz (LANTR-060108-04) CISPR22 CLASS A CONDUCTED EMISSIONS LINE 1
Freq. (MHz) 0.1500 0.1700 0.1700 0.1800 0.4600 22.8200 Meter Reading (dBuV) 38.48 34.70 33.40 33.82 37.47 34.82 Detector (PK/QP/AV) PK PK PK PK PK PK Average Limit (dBuV) 66.00 66.00 66.00 66.00 66.00 60.00 Average Delta(dB) -27.52 -31.30 -32.60 -32.18 -28.53 -25.18 Quasi-Peak Limit (dBuV) 79.00 79.00 79.00 79.00 79.00 73.00 Quasi-Peak Delta(dB) -40.52 -44.30 -45.60 -45.18 -41.53 -38.18

Page 3 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

Conducted Emissions Test Results (Continued) 230VAC/50HZ (LANTR-060108-04) CISPR22 CLASS A CONDUCTED EMISSIONS - LINE 2
Freq. (MHz) 0.1600 0.1700 0.2000 0.4300 18.3200 22.8200 Meter Reading (dBuV) 39.57 37.79 33.38 36.38 34.13 34.39 Detector (PK/QP/AV) PK PK PK PK PK PK Average Limit (dBuV) 66.00 66.00 66.00 66.00 60.00 60.00 Average Delta(dB) -26.43 -28.21 -32.62 -29.62 -25.87 -25.61 Quasi-Peak Limit (dBuV) 79.00 79.00 79.00 79.00 73.00 73.00 Quasi-Peak Delta(dB) -39.43 -41.21 -45.62 -42.62 -38.87 -38.61

Page 4 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

CONDUCTED EMISSIONS TEST RESULTS


CLIENT: EUT: MODEL NUMBER: SERIAL NUMBER: CONFIGURATION:
Lantronix External Device Server UDS1100 N/A 230 VAC / 50Hz

DATE: PROJECT NUMBER: TEST ENGINEER: SITE #: TEMPERATURE: HUMIDITY: TIME:

01/24/06 LANTR-060108 RJ 1 18 deg C 16% RH 8:40 AM

Description: Results:

Conducted Telecommunication Port Ethernet" RF Emissions (150 kHz 30 MHz) PASSED Voltage Limits

Page 5 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

Conducted Emissions Test Results (Continued)


TELECOM (QUANT-060108-05a) CISPR22 CLASS A CONDUCTED EMISSIONS TELECOM LINE
Freq. (MHz) Meter Reading (dBuV) Detector (PK/QP/AV) Average Limit (dBuV) Average Delta(dB) Quasi-Peak Limit (dBuV) Quasi-Peak Delta(dB)

0.46 1.11 2.03 11.76 13.35 16.14

63.89 56.73 56.25 56.93 57.67 56.91

PK PK PK PK PK PK

75.14 74.00 74.00 74.00 74.00 74.00

-11.25 -17.27 -17.75 -17.07 -16.33 -17.09

88.14 87.00 87.00 87.00 87.00 87.00

-24.25 -30.27 -30.75 -30.07 -29.33 -30.09

Page 6 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

RADIATED EMISSIONS TEST RESULTS


CLIENT: EUT: MODEL NUMBER: SERIAL NUMBER: CONFIGURATION: Lantronix External Device Server UDS1100 N/A 230 VAC / 50Hz DATE: PROJECT NUMBER: TEST ENGINEER: SITE #: TEMPERATURE: HUMIDITY: TIME: 01/23/06

LANTR-060108
RJ 1 21 deg. C 8% RH 03:15 AM

Description: Results:

Radiated RF Emissions (30 MHz 1000 MHz) PASSED Horizontal and Vertical Antenna Polarizations Class A Limits

Page 7 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

Radiated Emissions Test Results (Continued)


(LANTR-060108-03) CISPR22 CLASS A RADIATED EMISSIONS - Horizontal Antenna Polarization
Freq. (MHz) Meter Reading (dBuV) Antenna Height (cm) Azimuth (Degrees) Quasi Pk Or AVG (dBuV) Corrected Reading (dBuV/m) Limits (dBuV/m) Diff (dB) +=FAIL

110.77 240.00 288.00 336.01 375.00 750.00

14.07 8.01 8.14 15.99 18.76 3.94

400 400 300 300 300 300

0 0 90 0 270 0

26.51 27.49 31.01 34.29 36.96 30.37

40.00 47.00 47.00 47.00 47.00 47.00

-13.49 -19.51 -15.99 -12.71 -10.04 -16.63

(LANTR-060108-03) CISPR22 CLASS A RADIATED EMISSIONS - Vertical Antenna Polarization


Freq. (MHz) Meter Reading (dBuV) Antenna Height (cm) Azimuth (Degrees) Quasi Pk Or AVG (dBuV) Corrected Reading (dBuV/m) Limits (dBuV/m) Diff (dB) +=FAIL

110.67 229.99 288.00 375.00 445.42 750.00

9.63 3.70 4.95 12.81 6.66 5.30

100 100 100 100 100 100

0 90 90 0 90 180

23.50 23.71 28.81 31.21 27.21 31.73

40.00 40.00 47.00 47.00 47.00 47.00

-16.50 -16.29 -18.19 -15.79 -19.79 -15.27

Page 8 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

Electro-static Discharge Test Results


COMPANY: EUT: MODEL TESTED: SPEC.: LEVEL: PERFORMANCE CRITERIA: LANTRONIX External Device Server UDS1100 EN 61000-4-2: A2/2001 8.0 kV Air Discharge (Direct) 4.0 kV Contact Discharge (Direct/Indirect) B DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY:
+8kV.

02/02/06 RJ N/A 15 deg C 30.29 in 60% RH

TABLE 1: AIR DISCHARGE (Direct) Number of discharges per test point = 25ea, +2kV, +4kV, +6kV, Direct Discharge Location (EUT) Power Connector Serial Connector Ethernet Plastic Connector (discharge to RJ-45 connector shell) + 8.0 kV X X X

Pass / Fail/No Discharge Pass Pass Pass

Performance Criterion B B B

TABLE 2: CONTACT DISCHARGE (Direct) Number of discharges per test point = 25ea, +2kV & +4kV. Direct Discharge Location (EUT) Left Side of EUT Right Side of EUT Bottom Side of EUT Serial Connector Shell Ethernet Connector Shell + 4.0 kV X X X X X Pass / Fail Pass Pass Pass Pass Pass Performance Criterion B B B B B

Certification of Test Data:


Page 9 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

Electro-static Discharge Test Results (Continued)


COMPANY: EUT: MODEL TESTED: SPEC.: LEVEL: PERFORMANCE CRITERIA: LANTRONIX External Device Server UDS1100 EN 61000-4-2: A2/2001 8.0 kV Air Discharge (Direct) 4.0 kV Contact Discharge (Direct/Indirect) B DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY: 02/02/06 RJ N/A 16 deg C 30.29 in 61% RH

TABLE 3: CONTACT DISCHARGE (Indirect) Number of discharges per test point = 25ea. +2kV & +4kV. Indirect Discharge Location (EUT) HCP (All 4 Sides) VCP (All 4 Sides) + 4.0 kV X X Pass / Fail Pass Pass Performance Criterion B B

Certification of Test Data:

Page 10 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

Electrical Fast Transient / Burst Test Results


COMPANY: EUT: MODEL TESTED: SPEC. LEVEL: PERFORMANCE CRITERIA: LANTRONIX External Device Server UDS1100 EN 61000-4-4: A2 2002 1.0 kV Power Lines B DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY: 1/30/06 RJ N/A 4 deg C 30.29 in 100% RH

TABLE 4: Electrical Fast Transient Burst (Power Lines) EFT insertion point Line Neutral Protective Earth Line to Protective Earth Neutral to Protective Earth Line to Neutral Line to Neutral to Protective Earth
TEST LEVEL (kV) START VOLTAGE (kV)

+ 1.0 kV Pass X X X X X X X
STEP VOLTAGE (kV)

- 1.0 kV Fail Pass X X X X X X X


TEST DURATION (minutes)

Fail

Performance Criteria B B B B B B B

TIME BETWEEN TESTS (seconds)

1.0

0.500

0.500

1.0

60.0

Certification of Test Data:


Page 11 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

Surge Test Results


COMPANY: EUT: MODEL TESTED: SPEC. LEVEL: PERFORMANCE CRITERIA: LANTRONIX External Device Server UDS1100 EN 61000-4-5: A1/A2 2001 2.0 kV Common Mode 1.0 kV Differential Mode B DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY: 1/30/06 RJ N/A 9 deg C 30.29 in 90% RH

TABLE 5: Power Line Transients (Common Mode) Surge insertion point Line to Ground Neutral to Ground Line & Neutral to Ground
TEST LEVEL (kV)

+ 2.0 kV Pass X X X
STEP VOLTAGE (kV)

- 2.0 kV Fail Pass X X X


TEST DURATION (minutes)

Fail

Performance Criteria B B B
TIME BETWEEN TESTS (seconds)

START VOLTAGE (kV)

2.0

0.500

0.500

1.0

50.0

TABLE 6: Power Line Transients (Differential Mode) Surge insertion point Line to Neutral
TEST LEVEL (kV)

+ 1.0 kV Pass X Fail Pass X


STEP VOLTAGE (kV)

- 1.0 kV Fail

Performance Criteria B

START VOLTAGE (kV)

TEST DURATION (minutes)

TIME BETWEEN TESTS (seconds)

1.0

0.500

0.500

1.0

50.0

Certification of Test Data:


Page 12 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

Conducted Immunity Test Results


COMPANY: EUT: MODEL TESTED: SPEC. LEVEL: PERFORMANCE CRITERIA: LANTRONIX External Device Server UDS1100 EN 61000-4-6: A1/A2 2001 3.0 Vrms, 80% AM Modulated (1kHz) A DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY: 02/01/06 RJ N/A 15 C N/A 60%

TABLE 7: RF Conducted Susceptibility Test Location Power line Frequency range 0.15 80 MHz 3.0 Vrms Pass X Fail Performance Criteria A

Certification of Test Data:


Page 13 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

Voltage Dips and Interrupts Test Results

COMPANY: EUT: MODEL TESTED: SPEC. LEVEL: PERFORMANCE CRITERIA:

LANTRONIX External Device Server UDS1100 EN61000-4-11: A1 2002 >95%, 0.5 periods, 30%, 25 periods, >95%, 250 periods B (>95%, 0.5 periods), C (30%, 25 periods), C (>95%, 250 periods)

DATE: ENGINEER: S/N: AIR TEMPERATURE: BAROMETRIC PRESSURE: RELATIVE HUMIDITY:

1/30/06 RJ N/A 9 deg C 30.29 in

90% RH

Table 8: Voltage Dips and Interrupts Test (EN55024) Environmental Phenomenal Voltage Dip Voltage Dip Voltage Interruption Voltage Level 230 VAC 50Hz 230 VAC 50 Hz 230 VAC 50 Hz Reduction >95% reduction 30% reduction >95% reduction Duration 0.5 periods 25 periods 250 periods Results Pass X X X Fail Performance Criteria B C C

Certification of Test Data:

Page 14 of 14 (Appendix B) Report Number: LANTR-060108CE Revision Number: A3

APPENDIX C

PHOTOGRAPHS TEST SETUPS

Page 1 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

AC CONDUCTED EMISSIONS EN55022

CONDUCTED EMISSIONS FRONT VIEW FOR EUT: External Device Server MODEL NUMBER: UDS1100

Page 2 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

CONDUCTED EMISSIONS SIDE VIEW FOR EUT: External Device Server MODEL NUMBER: UDS1100

Page 3 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

RADIATED EMISSIONS FRONT VIEW FOR EUT: External Device Server MODEL NUMBER: UDS1100

Page 4 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

RADIATED EMISSIONS REAR VIEW FOR EUT: External Device Server MODEL NUMBER: UDS1100

Page 5 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

AC HARMONIC EMISSIONS / FLICKER EN61000-3-2 / EN61000-3-3

AC Harmonic Emissions / Flicker Tests Per EN61000-3-2 / EN61000-3-3

Page 6 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

ELECTROSTATIC DISCHARGE IMMUNITY TEST EN61000-4-2

Electrostatic Discharge Tests Per EN61000-4-2 Direct Air Discharge

Page 7 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

Electrostatic Discharge Immunity Test EN61000-4-2 (Continued)

Electrostatic Discharge Tests Per EN61000-4-2 Direct Contact Discharge

Page 8 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

Electrostatic Discharge Immunity Test EN61000-4-2 (Continued)

Electrostatic Discharge Tests Per EN61000-4-2 Indirect Contact Discharge (Vertical Coupling Plane)

Page 9 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

Electrostatic Discharge Immunity Test EN61000-4-2 (Continued)

Electrostatic Discharge Tests Per EN61000-4-2 Indirect Contact Discharge (Horizontal Coupling Plane)

Page 10 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST EN61000-4-3

Radiated Field Susceptibility Tests Per EN61000-4-3 Radiated Immunity

Page 11 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

ELECTRICAL FAST TRANSIENTS/BURST IMMUNITY TEST EN61000-4-4

Electrical Fast Transients/Burst Tests Per EN61000-4-4 Injection to Power Cable

Page 12 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

ELECTRICAL FAST TRANSIENTS/BURST IMMUNITY TEST EN61000-4-4

Electrical Fast Transients/Burst Tests Per EN61000-4-4 Injection to Signal Cable

Page 13 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

SURGE IMMUNITY TEST EN61000-4-5

Surge Immunity Tests Per EN61000-4-5 Injection to Power Cable

Page 14 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO FREQEUNCY FIELDS EN61000-4-6

RF Conducted Susceptibility Tests Per EN61000-4-6 Injection to Power Cable

Page 15 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO FREQEUNCY FIELDS EN61000-4-6

RF Conducted Susceptibility Tests Per EN61000-4-6 Injection to Signal Cable

Page 16 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST EN61000-4-8

Power Frequency Magnetic Field Immunity Test per EN61000-4-8 Injection on Enclosure

Page 17 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TEST EN61000-4-11

Voltage Dips and Interruptions Tests Per EN61000-4-11 Injection to Power Port

Page 18 of 18 (Appendix C) Report Number: LANTR-060108CE Revision Number: A3

APPENDIX D

CALIBRATION CORRECTION TABLE

Page 1 of 3 (Appendix D) Report Number: LANTR-060108CE Revision Number: A3

Calibration Correction Table Freq


30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 110.00 120.00 130.00 140.00 150.00 160.00 170.00 180.00 190.00 200.00 225.00 250.00 275.00 299.99 300.00 325.00 350.00 375.00 400.00 425.00

Index
0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 14.00 15.00 16.00 17.00 18.00 19.00 20.00 21.00 22.00 23.00 24.00 25.00 26.00 27.00

Cable Loss 10m


0.89 0.98 1.07 1.14 1.24 1.45 1.51 1.64 1.78 1.92 1.97 2.01 2.14 2.26 2.33 2.40 2.39 2.37 2.48 2.55 2.64 2.76 2.76 2.89 3.01 3.10 3.19 3.28

Horz. Ant 10m


13.50 11.50 10.40 9.80 9.60 9.40 9.60 10.10 10.60 11.20 11.70 12.00 12.40 12.90 13.30 14.10 14.50 15.10 16.30 17.40 19.60 20.70 14.30 15.40 15.30 15.10 15.90 16.10

Total
-14.39 -12.48 -11.47 -10.94 -10.84 -10.85 -11.11 -11.74 -12.38 -13.12 -13.67 -14.01 -14.54 -15.16 -15.63 -16.50 -16.89 -17.47 -18.78 -19.95 -22.24 -23.46 -17.06 -18.29 -18.31 -18.20 -19.09 -19.38

Vert. Ant 10m


13.70 10.70 9.30 8.80 9.60 9.90 9.80 10.60 12.20 10.40 9.60 9.80 11.40 13.90 13.70 14.40 14.20 14.50 17.30 18.40 20.90 21.40 14.20 15.40 15.40 15.30 16.00 16.30

Total
-14.59 -11.68 -10.37 -9.94 -10.84 -11.35 -11.31 -12.24 -13.98 -12.32 -11.57 -11.81 -13.54 -16.16 -16.03 -16.80 -16.59 -16.87 -19.78 -20.95 -23.54 -24.16 -16.96 -18.29 -18.41 -18.40 -19.19 -19.58

Page 2 of 3 (Appendix D) Report Number: LANTR-060108CE Revision Number: A3

Calibration Correction Table (Continued) Freq


450.00 475.00 500.00 525.00 550.00 575.00 600.00 625.00 650.00 675.00 700.00 725.00 750.00 775.00 800.00 825.00 850.00 875.00 900.00 925.00 950.00 975.00 1000.00

Index
28.00 29.00 30.00 31.00 32.00 33.00 34.00 35.00 36.00 37.00 38.00 39.00 40.00 41.00 42.00 43.00 44.00 45.00 46.00 47.00 48.00 49.00 50.00

Cable Loss 10m


3.37 3.48 3.60 3.70 3.81 3.92 4.02 4.10 4.18 4.16 4.14 4.28 4.43 4.49 4.54 4.61 4.68 4.89 5.10 5.13 5.15 5.22 5.28

Horz. Ant 10m


17.20 18.00 18.60 18.90 19.00 19.50 19.10 20.20 21.00 22.10 23.00 22.60 22.00 22.70 22.40 22.50 22.90 23.20 24.00 24.00 23.90 24.00 24.00

Total
-20.57 -21.49 -22.20 -22.61 -22.81 -23.42 -23.12 -24.30 -25.18 -26.26 -27.14 -26.89 -26.43 -27.19 -26.94 -27.11 -27.58 -28.09 -29.10 -29.13 -29.05 -29.22 -29.28

Vert. Ant 10m


17.40 17.80 18.50 18.80 18.90 19.50 19.50 20.00 20.70 21.60 22.30 22.00 22.00 22.60 22.20 22.00 22.30 22.70 23.50 23.70 23.40 23.40 23.50

Total
-20.77 -21.29 -22.10 -22.51 -22.71 -23.42 -23.52 -24.10 -24.88 -25.76 -26.44 -26.29 -26.43 -27.09 -26.74 -26.61 -26.98 -27.59 -28.60 -28.83 -28.55 -28.62 -28.78

Page 3 of 3 (Appendix D) Report Number: LANTR-060108CE Revision Number: A3

APPENDIX E

MODIFICATIONS AND RECOMMENDATIONS


1.0 None

Page 1 of 1 (Appendix E) Report Number: LANTR-060108CE Revision Number: A3

APPENDIX F

ACCREDITATION CERTIFICATE(S)

Page 1 of 4 (Appendix F) Report Number: LANTR-060108CE Revision Number: A3

Page 2 of 4 (Appendix F) Report Number: LANTR-060108CE Revision Number: A3

Page 3 of 4 (Appendix F) Report Number: LANTR-060108CE Revision Number: A3

Page 4 of 4 (Appendix F) Report Number: LANTR-060108CE Revision Number: A3

APPENDIX G

ADDITIONAL MODELS CONSIDERED UNDER SIMILARITY

Page 1 of 2 (Appendix G) Report Number: LANTR-060108CE Revision Number: A3

Model UDS1100 VDS100 NETCOM-1S

Configuration Tested All Three Configurations N/A N/A

Notes Device Tested Not Tested (See Note 1) Not Tested (See Note 2)

NOTE 1: According to the manufacturer this model is a lesser configuration than the UDS1100 that was tested. Because of their similarity it was decided by the manufacturer that the UDS1100 is worst-case test configuration when compared to the VDS100 since the UDS1100 has a DCDC converter 3.3V output and VDS100 does not. The VDS100 directly uses an external 3.3V source. NOTE 2: Identical to the UDS1100 that was tested.

Page 2 of 2 (Appendix G) Report Number: LANTR-060108CE Revision Number: A3