Sei sulla pagina 1di 2

12/20 (24) KV HXLP-DSTA

High Voltage Cross-Linked Polyethylene Three Cores Cable 12/20 (24) KV, Copper Conductor with Double Steel Tape Armor

Binding Tape Insulation Shield Steel Wire Conductor Shield

PE Sheath

Conductor Insulation Bedding PP Filler Cooper Tape

Armor Double steel tape Sheath Black polyethylene (ST 7) (Optional: Polyvinyl chloride)

Application
Preferably used for urban networks. Exposed in aerial, direct burial, conduit, open tray and underground duct installation.

Detail Description or Construction


Conductor Compact round stranded copper Conductor Shield Semi-conducting tape and/or Semiconducting cross-linked polyethylene Insulation Cross-linked polyethylene Insulation Shield Semi-conducting cross-linked polyethylene Shield Copper tape shield Filler Polypropylene (Nonhygroscopic material) Binding Tape Polyester and/or Spunbond tape Bedding Black polyethylene (Optional: Polyvinyl chloride)

Standards / Testing Specications


IEC 60502-2.

Marking
12/20 (24) KV HXLP-DSTA 3 X SIZE SQ.MM., PHELPS DODGE.

Installation
HXLP-DSTA cable can be installed in aerial, direct burial, conduit, open tray and underground. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safe guarding of persons and the integrity of the product will not be affected by deciencies in the installation.

www.pdic.com

PDIC01114 | 10.08.04

12/20 (24) KV HXLP-DSTA


High Voltage Cross-Linked Polyethylene Three Cores Cable 12/20 (24) KV, Copper Conductor with Double Steel Tape Armor

Nominal Sectional Area

Minimum Number of Wires

Diameter of Conductor (Approx) mm

Thickness of Insulation

Diameter Over Insulation (Approx)

Thickness of Steel Tape Armor

Diameter Over Armor (Approx)

Thickness of Sheath

Overall Diameter (Approx)

Maximum DC. Resistance of Cdr. @ 20C / km

Minimum Insulation Resistance @ 20C

Ampacities Direct Burial in Ground @ 30C Ambient** A

Allowable Ampacities in Free Air @ 40C Ambient A

Cable Weight (Approx)

Standard Packing

mm

mm

mm

mm

mm

mm

mm

M - km

kg / km

m / reel

35 50 70 95 120 150 185 240 300 400

7 7 18 18 18 18 34 34 34 55

6.9 8.0 9.7 11.4 12.9 14.2 16.0 18.4 20.5 23.4

5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5

18.7 19.8 21.5 23.2 25.0 26.2 28.1 30.5 32.8 36.2

2x0.5 2x0.5 2x0.5 2x0.5 2x0.5 2x0.5 2x0.5 2x0.8 2x0.8 2x0.8

51.3 53.8 57.5 61.3 65.2 69.1 73.2 79.8 84.9 92.6

2.7 2.8 3 3.1 3.2 3.3 3.4 3.6 3.8 4.0

58 61 65 69 73 77 81 88 94 102

0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470

1417 1297 1146 1031 929 870 795 716 652 578

160 190 230 275 310 345 385 435 480 530

175 205 255 305 350 390 445 510 575 645

3934 4500 5438 6510 7558 8745 10181 13166 15479 18735

500 500 500 250 250 250 250 250 250 250

**Depth of Laying in Ground 1 m, Rho = 1.2 C-m/watt

www.pdic.com

PDIC01114 | 10.08.04

Potrebbero piacerti anche