Product Overview MOVITRAC B

MOVITRAC B

MOVITRAC B

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

MOVITRAC B
Product phase-out of MC31C and MC07A
MC31C MOVITRAC B New components and production technology (MC31C: 1995/96) Modular design Smaller dimensions MOVITRAC 31C MC07A MOVITRAC B Compatible with MC07A Smaller dimensions Longer motor cable lengths Option-capable General information Extended power range (BG0XS, BG5, BG6) Additional functions Standardization MDX B / MC B Cheaper because option-capable
Driving the world

MOVITRAC B

MOVITRAC 07A
SES / Senger / Mai 2007

Product Overview MOVITRAC B

MOVITRAC B

MOVITRAC B BG 0

MOVITRAC B BG 2S 5 (6)

Monolith units

Control units
SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

Features of MOVITRAC B Size 0 Monolith


Single-board inverter (monolith unit) Compact, book-shaped design with IP 20 Power range: 230 V 1 ph 0.25 kW 2.2 kW 500 V 3 ph 0.25 kW 4.0 kW Overload capacity 125 % IN continuous duty 150 % IN for max. 60 sec. 200 % IN max. breakaway torque Integrated brake chopper

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

Features of MOVITRAC B Size 0 Monolith


Braking resistor can be mounted on the back Three-color status/diagnosis LED Integrated EMC line filter 1 ph units class B filter 3 ph units class A filter EMC filter can be deactivated "Cold Plate" installation possible

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

Unit overview MOVITRAC B Size 0 230 V 1 ph


MC07B-XXX-2B1-4-00 Mains voltage (AC) Power (kW) EMC filter Size BG0XS 0003 0004 0005 0008 0011 0015 0022

1 x 200 V 10 % ... 1 x 240 V +10 % 50 / 60 Hz 5 % 0.25 0.37 0.55 0.75 1.1 1.5 2.2

EMC filter class B integrated BG0S BG0L

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

Unit overview MOVITRAC B Size 0 500 V 3 ph


MC07B-XXX-5A3-4-00 Mains voltage (AC) Power (kW) EMC filter Size BG0XS 0.25 0003 0004 0005 0008 0011 0015 0022 0030 0040

3 x 380 V 10 % ... 1 x 500 V +10 % 0.37 0.55 0.75 1.1

50 / 60 Hz 5 % 2.2 3.0 4.0

1.5

EMC filter class A integrated BG0S BG0L

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

Unit overview MOVITRAC B Size 0 230 V 3-ph


MC07B-XXX-2A3-4-00 Mains voltage (AC) Power (kW) EMC filter Size BG0XS 0003 0004 0005 0008 0011 0015 0022

3 x 200 V 10 % ... 3 x 240 V +10 % 50 / 60 Hz 5 % 0,25 0,37 0,55 0,75 1,1 1,5 2,2

EMC filter class A integrated BG0S BG0L

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

Features of MOVITRAC B control unit


Modular design (control unit) MOVIDRIVE power sections BG2S BG5 (BG6) = 500 V units BG1 BG4 = 230 V 3-ph. units BG6 in preparation Overload capacity 125 % IN continuous duty 150 % IN for max. 60 sec. Three-color status/diagnosis LED Universal usabilty with BG0 Safe technology (since FW13)

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

Unit overview MOVITRAC B control units 500V


MC07B-XXX-5A3-4-00 Mains voltage (AC) Power (kW) EMC filter Size 5,5 7,5 0055 0075 0110 0150 0220 0300 0370 0450 0550 0750

3 x 380 V 10 % ... 1 x 500 V +10 % 11 15 22 30

50 / 60 Hz 5 % 37 45 55 75

EMC filter class A BG2S BG2 BG3 BG4 BG5

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

10

Unit overview MOVITRAC B control units 230V


MC07B-XXX-2A3-4-00 Mains voltage (AC) Power (kW) EMC filter Size BG1 3,7 0037 0055 0075 0110 0150 0220 0300

3 x 380 V 10 % ... 1 x 500 V +10 % 5,5 EMC filter class A BG2 BG3 7,5 11

50 / 60 Hz 5 % 15 22 30

BG4

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

11

Scope of MOVITRAC B functions


6 binary inputs (freely programmable) 3 binary outputs (1x relay) Analog input (0-10V) 24V input and output 10V reference for setpoint potentiometer (10k) TF supply + TF input Frequency input

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

12

New funtions MDX B terminals


Separable power terminals (up to BG 2S)

Separable control terminals

PI connection to grounding terminal (BG0)

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

13

Option capability

FBG11B keypad front option

FSC11B communication module FIO11B analog module (analog in- and output)

MDX B option cards can be used e.g. DFP21B with ULS11B

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

14

FBG11B option
FBG11B keypad front option 5 character LED display Operation similar to MC07A Extended operating features Additional key replaces double-click (MC07A) Parameter set backup Non-SEW motor startup

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

15

FSC11B option
FSC11B communication module option RS485 interface. Implemented as RJ10 socket for service and diagnostic purposes and as plug-in terminal for RS485 bus communication

CAN-based system bus (SBUS). Implemented as plug-in terminal

Terminating resistors for SBUS termination

24 V auxiliary power input and output

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

16

Option FIO11B
FIO11B analog module option Analog setpoint input AI2 useable for current or voltage setpoint setting

Analog output AO(V,C)1 useable as current 0(4)-20 mA or voltage output 0-10V

RS485 interface. Implemented as RJ10 socket for service and diagnostic purposes and as plug-in terminal for RS485 bus communication

Note: If using FIO11B, SBUS interface is not available


SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

17

DBG60B option (in preparation)


DBG60B keypad can be used with MOVITRAC B as an option

Option FIO11B or FCS11B is needed

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

18

Option MBG11A
Control device MBG11A can be used optional with MOVITRAC B

Option FIO11B or FCS11B is needed

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

19

Option UBP11A
Parameter module UBP11A can still be used

Option FIO11B or FCS11B is needed

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

20

Option capability of DFX fieldbus


MOVIDRIVE B fieldbus cards, e.g. DFP21B

If fieldbus card is installed, MC B can be used as gateway for up to 8 units

Standard fieldbus

8x

Communication via SBus


SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

21

Option capability new gateway


in combination with UOH11B housing new fieldbus gateway is available

several MOVIDRIVE B field bus cards can be used e.g. DFP21B

Standard fieldbus

8x

Communication via SBus


SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

22

Option capability of UFX fieldbus


You can still use UFX gateways

Standard fieldbus

8x

Communication via SBus


SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

23

Option capability MOVIPLC


MOVIPLC (DHP11B) can be operated in MOVITRAC B MOVIPLC (DHP11B) can also be used in UOH11B housing MOTION Library for MOVITRAC B available

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

24

New functions MC B IT network


Size 0 units can be modified to IT network versions Simple handling by inserting a plastic washer, EMC capacitors are insulated for operation in IT network Customer can adjust the unit Special designs no longer necessary

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

25

New functions MC B MOVITOOLS MOTION STUDIO


Engineering software MOVITOOLS MOTION STUDIO

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

26

New functions MDX B Scope function


Scope available as standard New extended Scope via MOVITOOLS MOTION STUDIO

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

27

New functions MC B extended fault memory


Extended fault memory Five fault memories (1 for MC07A)

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

28

Additional functions
Second set of parameter Bipolar analog input (0-10V) for external potentiometer Longer motor cables (MC07A = 25 / 50 m) Extended range of functions for the entire unit series - Hoist - Setpoint hold function - Flying start function in preparation

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

29

MOVITRAC B Technology Version


MOVITRAC B units as technology version available (since 12/2007) Units are comparable with MC07A LOGODRIVE, but without graphical programming environment For all MOVITRAC B units available

Unit designation e.g. MC07B0005-2B1-4-00/T

IPOS functionality application modules in preparation additional costs 95

SES / Senger / Mai 2007

Driving the world

Product Overview MOVITRAC B

MOVITRAC B

30

MOVITRAC B Monolith units with safety stop


New unit version of MOVITRAC B monolith units with safety stop function

Unit designation e.g. MC07B0005-2B1-4-00/S

Hardware is different to standard Monolith units (SMPS is different)

SES / Senger / Mai 2007

Driving the world