From Wikipedia, the free encyclopedia Jump to: navigation, search In physics and engineering, the time constant, usually denoted by the Greek letter (tau), is the risetime characterizing the response to a time-varying input of a first-order, linear timeinvariant (LTI) system.[1][note 1] The time constant is the main characteristic unit of a first-order LTI (linear time-invariant) system. In the time domain, the usual choice to explore the time response is through the step response to a step input, or the impulse response to a Dirac delta function input.[2] In the frequency domain (for example, looking at the Fourier transform of the step response, or using an input that is a simple sinusoidal function of time) the time constant also determines the bandwidth of a first-order time-invariant system, that is, the frequency at which the output signal power drops to half the value it has at low frequencies. The time constant also is used to characterize the frequency response of various signal processing systems magnetic tapes, radio transmitters and receivers, record cutting and replay equipment, and digital filters which can be modeled or approximated by first-order LTI systems. Other examples include time constant used in control systems for integral and derivative action controllers, which are often pneumatic, rather than electrical. Time constants are a feature of the lumped system analysis (lumped capacity analysis method) for thermal systems, used when objects cool or warm uniformly under the influence of convective cooling or warming.[3] Physically, the constant represents the time it takes the system's step response to reach of its final (asymptotic) value. In radioactive decay the time constant is called the decay constant (), and it represents both the mean lifetime of a decaying system (such as an atom) before it decays, or the time it takes for all but 36.8% of the atoms to decay. For this reason, the time constant is longer than the half-life, which is the time for only 50% of the atoms to decay.
Contents
[hide]
1 Differential equation o 1.1 Example solution 1.1.1 Discussion 1.1.2 Specific cases 2 Relation of time constant to bandwidth 3 Step response with arbitrary initial conditions 4 Examples of time constants o 4.1 Time constants in electrical circuits o 4.2 Thermal time constant o 4.3 Time constants in neurobiology
4.4 Exponential decay 4.5 Meteorological sensors 5 Notes 6 See also 7 References
o o
8 External links
The right-hand side is the forcing function f(t) describing an external driving function of time, which can be regarded as the system input, to which V(t) is the response, or system output. Typical choices for f(t) are the Heaviside step function, often denoted by u(t):
the impulse function, often denoted by (t), and also the sinusoidal input function:
or
where A is the amplitude of the forcing function, f is the frequency in Hertz, and = 2 f is the frequency in radians per second.
where
is the initial value of V. Thus, the response is an exponential decay with time constant . [edit] Discussion Suppose
This behavior is referred to as a "decaying" exponential function. The time (tau) is referred to as the "time constant" and can be used (as in this case) to indicate how rapidly an exponential function decays. Here: t = time (generally t > 0 in control engineering) V0 = initial value (see "specific cases" below). [edit] Specific cases 1) Let t = 0; then 2) Let t = ; then 3) Let 4) Let t = 5; then , and so V = V0 , 0.37A , and so , 0.0067A
After a period of one time constant the function reaches e1 = approximately 37% of its initial value. In case 4, after five time constants the function reaches a value less than 1% of its original. In most cases this 1% threshold is considered sufficient to assume that the function has decayed to zero - as a rule of thumb, in control engineering a stable system is one that exhibits such an overall damped behavior.
An example response of system to sine wave forcing function. Time axis in units of the time constant . The response damps out to become a simple sine wave.
Frequency response of system vs. frequency in units of the bandwidth f3dB. The response is normalized to a zero frequency value of unity, and drops to 1/2 at the bandwidth. Suppose the forcing function is chosen as sinusoidal so:
(Response to a real cosine or sine wave input can be obtained by taking the real or imaginary part of the final result by virtue of Euler's formula.) The general solution to this equation for times t 0 s, assuming V(t=0) = V0 is:
For long times the decaying exponentials become negligible and the so-called steady-state solution or long-time solution is:
By convention, the bandwidth of this system is the frequency where |V|2 drops to half-value, or where = 1. This is the usual bandwidth convention, defined as the frequency range where power drops by less than half (at most 3 dB). Using the frequency in hertz, rather than radians/s ( = 2f):
The notation f3dB stems from the expression of power in decibels and the observation that halfpower corresponds to a drop in the value of |V| by a factor of 1/2 or by 3 decibels. Thus, the time constant determines the bandwidth of this system.
Step response of system for two different initial values V0, one above the final value and one at zero. Long-time response is a constant, V. Time axis in units of the time constant . Suppose the forcing function is chosen as a step input so:
with u(t) the Heaviside step function. The general solution to this equation for times t 0 s, assuming V(t=0) = V0 is:
(It may be observed that this response is the 0 limit of the above response to a sinusoidal input.) The long-time solution is time independent and independent of initial conditions:
The time constant remains the same for the same system regardless of the starting conditions. Simply stated, a system approaches its final, steady-state situation at a constant rate, regardless of how close it is to that value at any arbitrary starting point. For example, consider an electric motor whose startup is well modeled by a first-order LTI system. Suppose that when started from rest, the motor takes of a second to reach 63% of its nominal speed of 100 RPM, or 63 RPMa shortfall of 37 RPM. Then it will be found that after the next of a second, the motor has sped up an additional 23 RPM, which equals 63% of that 37 RPM difference. This brings it to 86 RPMstill 14 RPM low. After a third of a second, the motor will have gained an additional 9 RPM (63% of that 14 RPM difference), putting it at 95 RPM.
In fact, given any initial speed s 100 RPM, of a second later this particular motor will have gained an additional .63 (100 s) RPM.
where R is the resistance (in ohms) and L is the inductance (in henries). Similarly, in an RC circuit composed of a single resistor and capacitor, the time constant (in seconds) is:
where R is the resistance (in ohms) and C is the capacitance (in farads). Of course, electrical circuits are usually much more complex than these examples, and may exhibit multiple time constants (See Step response and Pole splitting for some examples.) In the case where feedback is present, a system may exhibit unstable, increasing oscillations. In addition, physical electrical circuits are seldom truly linear systems except for very low amplitude excitations; however, the approximation of linearity is widely used.
where h is heat transfer coefficient, and As is the surface area, T(t) = body temperature at time t, and Ta is the constant ambient temperature. The positive sign indicates the convention that F is positive when heat is leaving the body because its temperature is higher than the ambient temperature (F is an outward flux). If heat is lost to the ambient, this heat transfer leads to a drop in temperature of the body given by:[4]
where = density, cp = specific heat and V is the body volume. The negative sign indicates the temperature drops when the heat transfer is outward from the body (that is, when F > 0). Equating these two expressions for the heat transfer,
Evidently, this is a first-order LTI system that can be cast in the form:
with
In other words, the time constant says that larger masses V and larger heat capacities cp lead to slower changes in temperature, while larger surface areas As and better heat transfer h lead to faster temperature changes. Comparison with the introductory differential equation suggests the possible generalization to time-varying ambient temperatures Ta. However, retaining the simple constant ambient example, by substituting the variable T (T Ta), one finds:
Systems for which cooling satisfies the above exponential equation are said to satisfy Newton's law of cooling. The solution to this equation suggests that, in such systems, the difference between the temperature of the system and its surroundings T as a function of time t, is given by:
where T0 is the initial temperature difference, at time t= 0. In words, the body assumes the same temperature as the ambient at an exponentially slow rate determined by the time constant.
where rm is the resistance across the membrane and cm is the capacitance of the membrane. The resistance across the membrane is a function of the number of open ion channels and the capacitance is a function of the properties of the lipid bilayer. The time constant is used to describe the rise and fall of the action potential, where the rise is described by
Where voltage is in millivolts, time is in seconds, and is in seconds. Vmax is defined as the maximum voltage attained in the action potential, where
where rm is the resistance across the membrane and I is the current. Setting for t = for the rise sets V(t) equal to 0.63Vmax. This means that the time constant is the time elapsed after 63% of Vmax has been reached Setting for t = for the fall sets V(t) equal to 0.37Vmax, meaning that the time constant is the time elapsed after it has fallen to 37% of Vmax. The larger a time constant is, the slower the rise or fall of the potential of neuron. A long time constant can result in temporal summation, or the algebraic summation of repeated potentials.
The reciprocal of the time constant is called the decay constant, and is denoted = 1 / .
[edit] Notes
1. ^ Concretely, a first-order LTI system is a system that can be modeled by a single first order differential equation in time. Examples include the simplest singlestage electrical RC circuits and RL circuits.
RC time constant Cutoff frequency Exponential decay Length constant Rise time Fall time Frequency response Impulse response Step response Transition time Settling time
[edit] References
1. ^ Bla G. Liptk (2003). Instrument Engineers' Handbook: Process control and optimization (4 ed.). CRC Press. p. 100. ISBN 0849310814. http://books.google.com/books?id=pPMursVsxlMC&pg=PA100. 2. ^ Bong Wie (1998). Space vehicle dynamics and control. American Institute of Aeronautics and Astronautics. p. 100. ISBN 1563472619. http://books.google.com/books?id=n97tEQvNyVgC&pg=PA100. 3. ^ GR North (1988). "Lessons from energy balance models". In Michael E. Schlesinger. Physically-based Modelling and Simulation of Climate and Climatic Change (NATO Advanced Study Institute on Physical-Based Modelling ed.). Springer. p. 627. ISBN 9027727899. http://books.google.com/books?id=oDsvwPWdkUC&pg=PA63#PPA627,M1. 4. ^ a b Roland Wynne Lewis, Perumal Nithiarasu, K. N. Seetharamu (2004). Fundamentals of the finite element method for heat and fluid flow. Wiley. p. 151. ISBN 0470847891. http://books.google.com/books?id=dzCeaWOSjRkC&pg=PA151.
Conversion of time constant to cutoff frequency fc and vice versa All about circuits - Voltage and current calculations