Sei sulla pagina 1di 2

Product data sheet

Characteristics

RE11RMMW

time delay relay 10 functions - 1 s..100 h 12..240 V AC/DC - 1 OC

Main
Range of product Product or component type Discrete output type Component name Time delay type Zelio Time Modular timing relay Relay RE11R A Ac At B Bw C D Di H Ht 0,1...1 s 1...10 s 6...60 s 1...10 min 6...60 min 1...10 h 10...100 h 12...240 V AC/DC 50/60 Hz 8A

Time delay range

[Us] rated supply voltage Nominal output current

Complementary
Contacts type and composition Contacts material Width pitch dimension Control type Voltage range Connections - terminals Housing material Repeat accuracy Temperature drift Voltage drift Setting accuracy of time delay Minimum pulse duration Reset time On-load factor Power consumption in VA Power consumption in W Minimum switching current Maximum switching current Maximum switching voltage Breaking capacity Breaking capacity Electrical durability Mechanical durability
Jan 24, 2013

1 C/O AgNi (cadmium free) 17,5 mm Selector switch front panel 0.85...1.1 Us Screw terminals 2 x 2.5 mm + 1 x 4 mm with cable end Screw terminals 2 x 1.5 mm without cable end Self-extinguishing +/- 0.5 % IEC 61812-1 +/- 0.05 %/C +/- 0.2 %/V +/- 10 % of full scale 25 C IEC 61812-1 30 ms 100 ms with load in parallel 100 ms on de-energisation 100 % 32 VA 240 V 0,6 W 24 V 1,5 W 240 V 10 mA 8A 250 V 2000 VA 80 W 100000 cycles 8 A 250 V resistive 5000000 cycles

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

[Uimp] rated impulse withstand voltage Marking Creepage distance Surge withstand Mounting support Local signalling

5 kV 1,2...50 s IEC 61812-1 5 kV 1,2...50 s IEC 60664-1 CE 4 kV/3 IEC 60664-1 1 kV differential mode IEC 61000-4-5 level 3 2 kV common mode IEC 61000-4-5 level 3 35 mm symmetrical mounting rail EN 50022 LED indicator green pulsing: relay energised, no timing in progress (except functions Di-D) LED indicator green flashing: timing in progress LED indicator green on steady: relay energised, no timing in progress 0,06 kg

Product weight

Environment
Immunity to microbreaks Dielectric strength Standards > 10 ms 2,5 kV 1 mA/1 minute 50 Hz IEC 61812-1 73/23/EEC 89/336/EEC 93/68/EEC EN 50081-1/2 EN 50082-1/2 IEC 60669-2-3 IEC 61812-1 CSA GL CULus -30...60 C -20...60 C IP20 terminal block IEC 60529 IP40 housing IEC 60529 IP50 front panel IEC 60529 0.35 mm 10...55 Hz IEC 60068-2-6 93 % without condensation IEC 60068-2-3 6 kV in contact IEC 61000-4-2 level 3 8 kV in air IEC 61000-4-2 level 3 10 V/m 80 MHz to 1 GHz ENV 50140/204 level 3 10 V/m 80 MHz to 1 GHz IEC 61000-4-3 level 3 1 kV capacitive connecting clip IEC 61000-4-4 level 3 2 kV direct IEC 61000-4-4 level 3 10 V 0.15...80 MHz ENV 50141 (IEC 61000-4-6) 30 % 10 ms IEC 61000-4-11 60 % 100 ms IEC 61000-4-11 95 % 5 s IEC 61000-4-11 Class B EN 55022 (EN 55011 group 1) 0622 Compliant

Product certifications

Ambient air temperature for storage Ambient air temperature for operation IP degree of protection

Vibration resistance Relative humidity Resistance to electrostatic discharge Resistance to electromagnetic fields Resistance to fast transients Immunity to radioelectric fields Immunity to voltage dips

Disturbance radiated/conducted RoHS EUR conformity date RoHS EUR status