Sei sulla pagina 1di 6

VEMKO GRP PIPES FOR~CIVILWORKS \

FIELDS OF APPLICATION: Civil works waste "'"Pollution control


..

..

Water mains

...Firefighting systems Penstocks Se.awater outfaHs .. Irrigation mains .. Waste water treatment plants

CHARACTERISTICS AND ADVANTAGES: Chemicalinertness Electrical insulation Thermal insulation - Ught weight

.
.

tii

..

.. Easy and fast installation"


.. High mechanical strenght .. Hydraulic properties - Non-toxicity .. No maintenance

INDUSTRIAL PIPES
FIELDS OF APPLICATION: .. Transport of corrosive fluids .. Fire fighting systems .. Water treatment plant~ Desulphurization plants DesaHnation plal}ts .. Industrilal sew~ge Transport of g~ and"va:poti,s - Cooling water syst9i:ns .. Seawater outfa

....

.......

'"

-t

4\

""

i:
F"'TTINGS f
Jj.

n
~

"
'M

.,
~

J..

{.
""~4 ...

'ti
-[" ~ "J! 1:1

- 90 Etbows anc;t..~an:g
,,~cQ.~conc. -" reducers ~~,,"
)es

,t

'11

'.
r
"", ""..""~,,.L.

"
,...:
!'.i< ""'~_"_"'W~""'..',r,'"."""""""",~"

",

-,'-",

VEMKO
..

"

rPM ~EBK~ 3A fPA.QE>KHVlWTBO

..

0611ACTI>1 HA npl>1MEHk
..

- Ko'HTpona

TpaMC90pT Ha ornaAHa BOAa

- Penstocks - IIIcnYMnHIiIcTaHlilqlil 38 MopCKa BOA8 - HaBOAHYBatbe - CTaHlilqH 3a npO"lIilCTYBatbe Ha oTnaAHa


BOAa

Ha 3araAYBatbe - BOAoBoAHa Mpe>Ka - CMcTeMIiI 3a npOTHB-nO>KapHa 3aWTIiITa

KAPAKrEPIffCT~r<~j,HAP~I;I()CTH: - XeMHCl(aorn~pHoC'" - EneKTpM"tHiIH30llaqtd}a - TepMa.nHa,"~n).qal4irtja'


~

..
~

11'.
r ~

Nfa.na Te>K'1:1'ta

- EAHacTaBHa H'Qp3il j,t"cTa~qMja


- rOneMat./JeXat:llot'4KS '~Br:sctJlt\.(a - XIiIApay.nK'iIiM cBojc.Taa
HeTOKCH'"IHOCT:

- HeMa naHaTaMOWtfO aAf?>t<yaatbe


Ji
i' A

I,

. fI

~H.QYCTPVlCKVI ~EBKVI
OBflACTH

..'!l'
KAPAKT EP1>1CTVIK/,1RP 'IHO~J\.1,/ ~

'"

,.

HA np/,1MEHA:

npeHOC Ha KOpO3HBHH ~nYIiIAH CIiICTeMIiI3a npOTIiIB-nO>KapHa 3aWTHTa

"

- npe'"lHCTHTenHIiI cTaHlilqH 3a BOAa CTaHlilqH 3a AecymPYPH3aqHja CTaHHqH 3a AecanHHaqHja IIIHAYCTPHC,KIiI omaA

- OrpaHH'"IeHO OAP>KY.Bc:\)P. - Mana Te>KHHa


- EAHOCTaBHa
- rOneMa
H.6p3alil'Hciii
,

- OTl'1o.pHOCTHanOBeJtet~MaJ\firl1.
A
a
,

....

J
.A
~<I"

~ ~

'~

11 ... ."

~~a
.#

,~

, . MeXaHH'fKa qBPCJHtlti

..

- ~~~.~

,.,~,~.. H napea raG :,"C T e ~~~ etjSl1)~~,.BO~~


cTaHkI.{M 3a MOPQKCIIQA; f

- /,1cnnaT11Ii1B.2fT'"

"..,.

~
J)

'tJ

..
J

-~ -

:J

l"CnYMrtHIiI

..1-

(j

.;
"" A

.).. I
,d

,I iJ ill

"'" "

.,
\

.
I:' ..

'"

..

'"

'oncer HAUEBKH <l>A30HCKHnAP4,VI,Jb.A J4


'TeXI1H'"IKIiI KapaKT~pHCTIiIKIiI
~

BH'ilTpeweH Jipf,fTHcqK: 0 AO50 bar anconytpfI

"

: 'IIItQ>lfHaKPPKCTet;bf!'
-,
..

cnoES/,1

Ha Me~HIiI~1iI ctlp(;)B'f,

fffi

f;lO!'l'.,flan1:lM AHjaNieTpH PN 25 Aa ON.4000, rrrm. .'~' k AOn>KM!:,~.Ha qeBKM : Aa 12' tU f. '" 11:,' Pa60,THa'7\"eMnep~TYpa : Ao iJO<>C ~ - H8o"an81;\t4ja : QoA3eMI1ak~,~ J:iaa3ellltH8\ .,
i~' ,',

. (f.>r~sA fng Jo:~t!son,Straub)~ rpn CnOe8K,co QMJ;Jl1tt~pIil'4Ha HI:iMstta

C'b:<My4>,cnoeBK~O<Al3aO"f\ipg~a: '\I.t UlAH" 'a "'l..a,,4tlJ, ~j

"

CI(Kcnoe'aM '" ~

.~..e _110~;I!I~'~Q4PtJaHtQJo1

<I>.6.30N.CKVlftAIi'J\1'I-bA '. ~
1iI~:ci:11ea~ t$HR~ p,..A~K"Hla 8M ~;.~. , " u

~1

'0 -" '

i. ,\
~ \

TMnOBM HA CnOEBM - JOINT TYPES

~
j

- rpn LllllnIllH,Qplll"'lHIII HaBnaKIIIco oclllrypYBa4 - GRP sleeve joints with locking key

- CnoeBIIIo c

aI1v
MYCP

co ,QBaO-Ring-a

~:~

- CnoeBIII co MYCPco ,QBa

III oclllryPYBa"'l

- Belland spigot joints with double a-Ring and lockingkey

O-Ring-a - Belland spigotjoints with doublea-Ring

=C__:___l4eneH cnoj GO naMIIIHal\lIIja

l~V~
6eToHcKIII cnoeBIII

MexaHlt14Klt1cnoeBIII

- Butt and strap joints

Cemented joints

- Mechanical

joints

~H)f(EHEP~Hr

- ENGINEERING
by Det Norske Veritas Full traceability of materials according to EN 10204 3.1.b. - Assistance in designing the supporting system - Stress analysis - Installation procedures - Training of installation personnel - Assistance and supervision to erection/commissioning - Design according to UNI 9032-9033 and AWWA standards

- Clt1CTeM
-

3a KBanlllTeT cnope,Q O,QDet Norske Veritas

ISO EN 9001 CepTlt1cpIllLllt1paH - 9uality System according to ISO EN 9001 certified

KoMnneTHa KoHTpona Ha MaTeplt1janlt1 ynoTpe6eHlt1 no CTaH,Qap,QEN 10204 3.1.b.


no,Q,QpWKa

- nOMOWnplll ,Q1II3ajHlt1pal-be CIIICTeMIIITe Ha 3a

CTpec aHanlll3a

npoLle,QYPIll a IIIHCTanaLllt1ja 3
06YKa Ha nepcoHanoT 3a lt1HCTanal\lIIja III cynepBIII3111jaHa MOHTa>Ka AIII3ajH cnope,Q UNI 9032-9033 IIIAWWA cTaH,Qap,QIIITe

- nOMOW

.{
\.

HA4V1HVI CnOJYBAI-bE- FITTINGS HA


FOR GLUED OR MECHANICAL JOINT WITH DOUBLE a-RING
..

"

3A 4EnEH cnOJ co nAMVlHALlVlJA FOR BUTT & STRAP JOINT

@
Q5

Kpl<1BI<1HI<1 90 OA 90 Elbows

Kpl<1BI<1HI<1OA 45

45 Elbows

a
I

~
BEE
-M

EKcl..\.lKOHI..\. peAYKl..\l<1ja

Ecc.lconc. Reducers

~
-Et

TIY

pa'-lBI<1

TIY Branches

<DnaHWI<1

-rut

Flanges

VlH.QYCTPVlCKVI UEBKVI- INDUSTRIAL PIPES

cnOPE.QHAPA4KA UPONREQUEST CnpOBOAHI<1 CI<1CTeMI<1 enl<1MI<1Hl<1pal-beHa 3a eneKTpOCTaTI<1'-1KI<1OTnOpl<1 - TepMol<130nl<1paHI<1 l..\eBKOBOAI<1co I<1nl<1 e3 eneKTpl<1'-1HO 6 3arpeBal-be LleBKoBoAI<1 co roneMa HaABopeWHa ep031<1ja OTnOpHOCT Ha BHaTpeWHa 1<1

- Conductive systems to avoid static build-up - Thermoinsulated piping systems with or without heat tracing - Piping systems with high resistance to internal and external erosion

rpn UEBKVI3A rPA.QE>KHVlWTBOGRP PIPES FOR CIVIL WORKS cnOPE.Q HAPA4KA- UPON REQUEST
rpn l..\eBKI<1 MO>KaTAa ce AocTaBaT:
BeHTl<1n 3a TeCTt-1pal-be, nOCTaBeH noMety ABa

Co

O-ring-a - Co ocl<1rypYBa'-l - Co BHaTpeweH 1<1 HaABopeweH cnoj, OTnOpeHHa


a6pa31<1ja

GRP pipes can be supplied: - With test nipple plac,edbetween the 2 a-ring gaskets - With locking device - With internal and external abrasion-resistant liners

Potrebbero piacerti anche