TESTING AND SUBSEA

Diverter Manifold

Halliburton Testing and Subsea diverter manifolds are located downstream of the surface well test equipment package with the purpose of allowing a safe means to manually divert the gas and oil ow, without interruption, from one burner boom to another in the event of wind change or other scenario requirements. Diverter manifolds are also used in conjunction with the air supply for the burner booms. Diverter manifolds are constructed as skid units, manufactured to meet DNV 2.7-3 lifting codes as well as appropriate ANSI/ASME/NACE requirements. Types Oil Manifold: Located downstream of the separator and providing the capability to divert oil ow to the appropriate burner boom or designated aring or storage area, such as surge tank or atmospheric tank. Skids are available in 2-valve and 5-valve versions, each comprised of 3-in. Fig 206, ANSI 600-lb Balon ball valves. Gas Manifold: Located downstream of the separator and used to divert the produced gas ow from the separator to the appropriate burner boom or designated aring area. Skids are available in 4-in. and 6-in. Fig 206, ANSI 600-lb Balon ball valve versions. Air Manifold: Located in the air compressor area and used to divert airow to the appropriate burner boom during well test operations. The skid is comprised of two 4-in. Fig 206, ANSI 150-lb Balon ball valves. Features Skid-mounted units that are manufactured to meet DNV 2.7-3 lift frame requirements
HAL32607

Meets all required ANSI / ASME requirements for piping and valves Meets NACE MR-01-75 Service standards Benets Allows exibility to direct oil and gas produced from the separator to burners, storage tanks, production lines, or other destinations to meet customer requirements Helps ensure that the oil and gas ow can be diverted safely without interruption
Diverter Manifold

Divert oil and gas to the safest burner with respect to wind direction Skid-mounted to allow ease of placement at the site

TESTING AND SUBSEA

Diverter Manifold Specications


Part Number Description Working Pressure psig (MPa) Working Temperature F (C) Service Standard Valve Type Connections: Inlet Outlets Skid Dimensions (L W H) ft (m) 101788315 Oil Diverter Manifold (2 valve/3-in.) 1,440 (9.93) -20 to 100 (-29 to 38) H2S NACE MR0175 3-in. ANSI 600lb Balon ball valves 3-in. 206 Thread 2 x 3-in. 206 Wing 4.8 1.6 2.2 (1.5 0.5 0.7) 101919715 101788316 101828618 101840912 Oil Diverter Manifold Gas Diverter Manifold Gas Diverter Manifold Air Diverter Manifold (2 valve/4-in.) (2 valve/6-in.) (2 valve/4-in.) (5 valve/3-in.) 1,440 (9.93) -20 to 100 (-29 to 38) H2S NACE MR0175 3-in. ANSI 600lb Balon ball valves 3-in. 206 Thread 3 x 3-in. 206 Wing 4.8 1.6 2.2 (1.5 0.5 0.7) 1,440 (9.93) -20 to 100 (-29 to 38) H2S NACE MR0175 4-iin. ANSI 600lb Balon ball valves 4-in. 206 Thread 2 x 4-in. 206 Wing 5.7 1.6 2.2 (1.7 0.5 0.7) 1,440 (9.93) -20 to 100 (-29 to 38) H2S NACE MR0175 6-in. ANSI 600lb Balon ball valves 6-in. 206 Thread 2 x 6-in. 206 Wing 5.7 1.6 2.2 (1.7 0.5 0.7) 250 (1.72) -20 to 200 (-29 to 93) H2S NACE MR0175 4-in. ANSI 150lb Balon ball valves 4-in. 206 Thread 2 x 4-in.206 Wing 5.7 1.6 2.2 (1.7 0.5 0.7)

For more information about Halliburtons Diverter Manifolds, contact your local Halliburton representative or email us at welltesting@halliburton.com.