Chapter 1 Alarms........................................................................................................................... 1-1 1.1 Introduction ........................................................................................................................ 1-1 1.2 Alarm Message Content .................................................................................................... 1-1 1.2.1 Alarm Message Format........................................................................................... 1-1 1.2.2 Alarm Message Description .................................................................................... 1-3 1.2.3 Alarm Level ............................................................................................................. 1-3 1.2.4 Alarm Modules ........................................................................................................ 1-4 1.2.5 Alarm Parameters ................................................................................................... 1-4 1.2.6 Function Types........................................................................................................ 1-4 Chapter 2 Alarm Messages .......................................................................................................... 2-1 2.1 802.1x ................................................................................................................................ 2-1 2.1.1 8021X/2/PRXYCHKED: 1.3.6.1.4.1.2011.5.22.1.0.1 .............................................. 2-1 2.2 BGP ................................................................................................................................... 2-2 2.2.1 bgp/1/Trap4: 1.3.6.1.2.1.15.7.1............................................................................... 2-2 2.2.2 bgp/1/Trap4: 1.3.6.1.2.1.15.7.2............................................................................... 2-2 2.3 LDP .................................................................................................................................... 2-3 2.3.1 LDP/5/TRAP: 1.3.6.1.4.1.2011.5.12.2.2.0.15 ......................................................... 2-3 2.3.2 LDP/5/TRAP: 1.3.6.1.4.1.2011.5.12.2.2.0.16 ......................................................... 2-4 2.4 LSPM ................................................................................................................................. 2-5 2.4.1 LSPM/5/TRAP: 1.3.6.1.2.1.10.166.2.0.1................................................................. 2-5 2.4.2 LSPM/5/TRAP: 1.3.6.1.2.1.10.166.2.0.2................................................................. 2-5 2.5 OSPF ................................................................................................................................. 2-6 2.5.1 OSPF/1/ Trap1: 1.3.6.1.2.1.14.16.2.1 ..................................................................... 2-6 2.5.2 OSPF/1/Trap2: 1.3.6.1.2.1.14.16.2.2 ...................................................................... 2-7 2.5.3 OSPF/1/ Trap3: 1.3.6.1.2.1.14.16.2.3 ..................................................................... 2-8 2.5.4 OSPF/1/ Trap4: 1.3.6.1.2.1.14.16.2.4 ..................................................................... 2-9 2.5.5 OSPF/1/ Trap5: 1.3.6.1.2.1.14.16.2.5 ................................................................... 2-10 2.5.6 OSPF/1/ Trap6: 1.3.6.1.2.1.14.16.2.6 ................................................................... 2-11 2.5.7 OSPF/1/ Trap7: 1.3.6.1.2.1.14.16.2.7 ................................................................... 2-11 2.5.8 OSPF/1/ Trap8: 1.3.6.1.2.1.14.16.2.8 ................................................................... 2-12 2.5.9 OSPF/1/ Trap9: 1.3.6.1.2.1.14.16.2.9 ................................................................... 2-13 2.5.10 OSPF/1/ Trap10: 1.3.6.1.2.1.14.16.2.10............................................................. 2-14 2.5.11 OSPF/1/ Trap11: 1.3.6.1.2.1.14.16.2.11............................................................. 2-15 2.5.12 OSPF/1/ Trap12: 1.3.6.1.2.1.14.16.2.12............................................................. 2-16 2.5.13 OSPF/1/ Trap13: 1.3.6.1.2.1.14.16.2.13............................................................. 2-17 2.5.14 OSPF/1/ Trap14: 1.3.6.1.2.1.14.16.2.14............................................................. 2-18 2.5.15 OSPF/1/ Trap15: 1.3.6.1.2.1.14.16.2.15............................................................. 2-19 2.5.16 OSPF/1/ Trap16: 1.3.6.1.2.1.14.16.2.16............................................................. 2-19
1-1

H3C S9500 Trap Message

2.6 MSTP ............................................................................................................................... 2-20 2.6.1 MSTP/2/ ROOT: 1.3.6.1.4.1.2011.2.23.1.14.0.3................................................... 2-20 2.6.2 MSTP/2/ RGSUP: 1.3.6.1.4.1.2011.2.23.1.14.0.4 ................................................ 2-21 2.6.3 MSTP/2/ IVBPDU: 1.3.6.1.4.1.2011.2.23.1.14.0.5................................................ 2-22 2.6.4 MSTP/2/ LGEXP: 1.3.6.1.4.1.2011.2.23.1.14.0.6 ................................................. 2-23 2.7 POS ................................................................................................................................. 2-23 2.7.1 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.5....................................................... 2-23 2.7.2 POS/2/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.2....................................................... 2-24 2.7.3 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.3....................................................... 2-24 2.7.4 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.6....................................................... 2-25 2.7.5 POS/2/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.1....................................................... 2-25 2.7.6 POS/2/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.8....................................................... 2-26 2.7.7 POS/2/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.4....................................................... 2-27 2.7.8 POS/2/ TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.7...................................................... 2-27 2.7.9 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.9....................................................... 2-28 2.7.10 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.10................................................... 2-28 2.7.11 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.11................................................... 2-29 2.7.12 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.12................................................... 2-29 2.7.13 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.13................................................... 2-30 2.8 VRRP ............................................................................................................................... 2-30 2.8.1 vrrp/5/TrapBecomeNewMaster: 1.3.6.1.2.1.68.0.1 ............................................... 2-30 2.8.2 vrrp/4/ TrapAuthFailed: 1.3.6.1.2.1.68.0.2 ............................................................ 2-31 2.9 DEV.................................................................................................................................. 2-32 2.9.1 DEV/2/POWER STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.1 2-32 2.9.2 DEV/2/POWER STATE CHANGE TO NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.2 2-32 2.9.3 DEV/2/POWER REMOVED: 1.3.6.1.4.1.2011.2.23.1.12.1.5................................ 2-33 2.9.4 DEV/2/FAN STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.6...... 2-34 2.9.5 DEV/2/FAN STATE CHANGE TO NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.7...... 2-34 2.9.6 DEV/2/BOARD REMOVED: 1.3.6.1.4.1.2011.2.23.1.12.1.8 ................................ 2-35 2.9.7 DEV/2/BOARD INSERTED: 1.3.6.1.4.1.2011.2.23.1.12.1.9 ................................ 2-36 2.9.8 DEV/2/BOARD STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.102-36 2.9.9 DEV/2/BOARD STATE CHANGE TO NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.112-37 2.9.10 DEV/2/BOARD TEMPERATURE LOWER: 1.3.6.1.4.1.2011.2.23.1.12.1.14 ..... 2-38 2.9.11 DEV/2/BOARD TEMPERATURE NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.15... 2-38 2.9.12 DEV/2/BOARD TEMPERATURE UPPER 1.3.6.1.4.1.2011.2.23.1.12.1.16 ....... 2-39 2.9.13 DEV/2/BOARD TEMPERATURE NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.17... 2-40 2.9.14 DEV/2/BOARD REQUEST LOADING: 1.3.6.1.4.1.2011.2.23.1.12.1.18 ............ 2-40 2.9.15 DEV/2/LOAD FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.19 .................................. 2-41 2.9.16 DEV/2/LOAD FINISHED: 1.3.6.1.4.1.2011.2.23.1.12.1.20................................. 2-42 2.9.17 DEV/2/POWER INSERT: 1.3.6.1.4.1.2011.2.23.1.12.1.23................................. 2-42 2.9.18 DEV/2/PORT POE POWER ON: 1.3.6.1.2.1.105.0.1 ......................................... 2-43 2.9.19 DEV/2/PSE POWER USAGE OVER THRESHOLD: 1.3.6.1.2.1.105.0.1........... 2-43 2.9.20 DEV/2/PSE POWER USAGE BELOW THRESHOLD: 1.3.6.1.2.1.105.0.3........ 2-44
1-2

H3C S9500 Trap Message

2.9.21 DEV/2/PD PULL: 1.3.6.1.4.1.2011.10.2.14.6.1................................................... 2-45 2.9.22 DEV/2/PD PULL: 1.3.6.1.4.1.2011.10.2.14.6.1................................................... 2-45 2.10 ENTITY .......................................................................................................................... 2-46 2.10.1 ENTITY/5/CONFIG CHANGE: 1.3.6.1.2.1.47.2.0.1............................................ 2-46 2.11 HWCM ........................................................................................................................... 2-47 2.11.1 HWCM/5/TRAP:1.3.6.1.4.1.2011.10.2.4.2.1....................................................... 2-47 2.11.2 HWCM/5/CFGCOPY: 1.3.6.1.4.1.2011.10.2.4.2.2.............................................. 2-48 2.12 L2INF ............................................................................................................................. 2-49 2.12.1 L2INF/2/ PORT LINK STATUS CHANGE: 1.3.6.1.6.3.1.1.5.4 ........................... 2-49 2.12.2 L2INF/2/PORT LINK STATUS CHANGE: 1.3.6.1.6.3.1.1.5.3 ............................ 2-49 2.13 MIX................................................................................................................................. 2-50 2.13.1 MIX/2/SLAVE SWITCH OVER: 1.3.6.1.4.1.2011.2.23.1.17.10.1 ....................... 2-50 2.14 RMON ............................................................................................................................ 2-51 2.14.1 rmon/2/ ALARMUP: 1.3.6.1.2.1.16.0.1 ............................................................... 2-51 2.14.2 rmon/2/ ALARMFALL: 1.3.6.1.2.1.16.0.2............................................................ 2-51 2.14.3 rmon/2/ RISING: 1.3.6.1.4.1.2011.1.3.4.0.1 ....................................................... 2-52 2.14.4 rmon/2/FALLING: 1.3.6.1.4.1.2011.1.3.4.0.2...................................................... 2-53 2.15 VFS ................................................................................................................................ 2-54 2.15.1 VFS/5/TRAP: 1.3.6.1.4.1.2011.10.2.5.1.3.1 ....................................................... 2-54 2.16 SNMP-V2 ....................................................................................................................... 2-55 2.16.1 ColdStart: 1.3.6.1.6.3.1.1.5.1 .............................................................................. 2-55 2.16.2 WarmStart: 1.3.6.1.6.3.1.1.5.2 ............................................................................ 2-55 2.16.3 AuthenticationFailure: 1.3.6.1.6.3.1.1.5.5 ........................................................... 2-56

1-3

H3C S9500 Trap Message

Chapter 1 Alarms
1.1 Introduction
When a device fails or the system does not function somehow, the system generates an alarm based on the fault type and the faulty module, and saves the alarm in the alarm buffer of the device. At the same time, the system generates a log. You can determine the size of the alarm buffer as actually needed. If the Network Management System (NMS) is present, the alarm is sent to the NMS through the Simple Network Management Protocol (SNMP). The system can also sense the environment. When the device works beyond its limits, the system generates an alarm. The equipment enables you to view alarm messages on the terminal. Alarm messages are displayed on the terminal interface, and saved in the buffer. You can also view all the alarms saved in the buffer using a command on the device. Alarm messages fall into the following three categories in terms of nature: Failure alarms: Alarms generated due to the failure of hardware or some key functions; Recovery alarms: Alarms generated when the faulty device or abnormal functions are recovered; Event alarms: Warnings or alarms generated when the fault and the recovery messages do not match.

1.2 Alarm Message Content


This section includes the following contents: Alarm Message Format Alarm Message Description Alarm Level Alarm Modules Alarm Parameters

1.2.1 Alarm Message Format


An alarm starts with a # and takes the following format.

1-1

H3C S9500 Trap Message

Description

Figure 1-1 Alarm output format The fields in the format are described as follows. TimeStamp It specifies the time when the alarm is generated. It is in the format of Mmm dd hh:mm:ss yyyy. Mmm stands for the month in English, that is, Jan, Feb, Mar, Apr, May, Jun, Jul, Aug, Sep, Oct, Nove, and Dec. dd is the date. If the value is smaller than 10, fill in as space + date, such as 7. hh:mm:ss is the local time. hh uses the 24-hour system, with a value ranging from 00 to 23. The values for both "mm" and ss range from 00 to 59. yyyy specifies the year. TimeStamp is separated from HostName by a space. HostName It is the system name of the host, H3C by default. HostName is separated from ModuleName by a space. ModuleName It specifies the module that generates the alarm. ModuleName is separated from Alarm level by a slash (/). Alarm Level Alarms fall into four Alarm level ranks, ranging from 1 to 4. Alarm level is separated from Brief by a slash (/). Brief It contains a short term to brief the alarm. Brief is separated from Description by a colon (:). Description It contains the character string sent by the module to the information center to detail the specific content of this alarm.

TimeStamp

HostName

AlarmLevel

ModuleName
1-2

Brief

H3C S9500 Trap Message

1.2.2 Alarm Message Description


I. Basic information
See the following table. Table 1-1 List of basic parameters in an alarm message
Item Alarm message Alarm OID Alarm meaning Alarm type Alarm level Alarm parameter Function type Description Character string of alarm message displayed on the device. Object ID defined in the MIB file. The meaning of the alarm message. The nature of the alarm message. Impacts of the failure upon the service. Paramters contained in the alarm message used for alarm location and translation. It specifies the function domain to which the fault belongs.

II. Trigger action


It describes probable causes of the alarm message, and locates the exact reasons.

III. Recommended action


It provides the advice for further diagnosis and recovery based on the cause of the alarm message.

IV. Related alarm message


It describes the related alarm message to locate the root cause of the alarm message and reasons related alarm message occurs.

1.2.3 Alarm Level


The alarm level identifies the severity of an alarm message. It has the following four ranks with severity in a descending sequence: Critical, Major, Minor, and Warning. For descriptions, see the following table. Table 1-2 Alarm level description
Alarm level 1 Definition Critical Description Such failure affects the services provided by the system and requires action at once. For example, when certain device or resource is completely unavailable, it requires recovery at once. Even if the failure occurs outside the working time, immediate actions are required. Such failure affects the quality of the service, and requires urgent recovery. For example, when the quality of certain device or resource declines, it must be restored so that the full capatility is recovered. In the case of occurrence in working hours, immediate actions are required. Such failure does not affect the quality of the service at the moment. But to avoid more severe failures, processing at proper time or further observation is required. Such failure indicates that there may be potential errors that affect the service. Related measures vary with the errors.

2 3 4

Major Minor Warning

1-3

H3C S9500 Trap Message

1.2.4 Alarm Modules


The following table shows the abbreviations of alarm modules. Table 1-3 Descriptions of alarm module abbreviations
Alarm Module 802.1X BGP LDP LSPM OSPF MSTP POS VRRP DEV ENTITY HWCM L2INF MIX RMON VFS SNMP-V2 802.1X protocol module BGP module Label Distribution Protocol module LSP Management module OSPF module MSTP module POS management module VRRP module Device management module Entity MIB module Configuration Management module Layer 2 Interface management module Slave Swtichover management module RMON module File management module SNMP-V2 module Description

1.2.5 Alarm Parameters


The following table describes the variables in alarm parameters. Table 1-4 Explanations of alarm parameters
Alarm parameter Description

1.2.6 Function Types


The following table describes the function types. Table 1-5 Explanations of function types
Function type Communication alarm Service quality alarm Alarm for error handling Environmental alarm Equipment alarm Description Such alarms are related to the handling process of message transmission, including alarms generated in communication failures between NEs, NE and OS, or OSs. Such alarms result from reduction of the service quality, including alarms generated in congestion, performance reduction, high resource occupation rate, and bandwidth reduction. Such alarms result from software or handling process errors, including alarms generated in service processing such as software error, memory overflow, unmatched versions, and abnormal interruption of programs. Such alarms result from problems related to the location of the device, including alarms generated when the temperature, humidity and ventilation in the environment are abnormal. Such alarms result from faults of physical resources, including alarms generated by devices such as the power, fan, processor, clock, and input or output interface.

1-4

H3C S9500 Trap Message

Trap Messages

Chapter 2 Alarm Messages


2.1 802.1x
2.1.1 8021X/2/PRXYCHKED: 1.3.6.1.4.1.2011.5.22.1.0.1
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Description The smart proxy-checker report! 1.3.6.1.4.1.2011.5.22.1.0.1 supplicantproxycheck None It is detected that the user connects to the Internet through an agent. Event alarm Warning $1: Alarm OID $2: VLAN ID $3: Port Name $4: MAC Address $5: IP Address $6: User Name Communication alarm

Alarm parameter

Function type

II. Trigger action


This alarm message has the following trigger actions: The user connects to the Internet through an Agent; There are multiple network cards on the device; The user connects to the Internet through the IE agent.

III. Recommended action


Based on the causes of the alarm message, the suggestions for recovery include: Notify the user to eliminate the agent

IV. Related alarm message


None

2-1

H3C S9500 Trap Message

Trap Messages

2.2 BGP
2.2.1 bgp/1/Trap4: 1.3.6.1.2.1.15.7.1
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description connection established [oid] BgpPeerRemoteAddr = [ipaddr] BgpPeerLastError = [octet] BgpPeerState = [integer] 1.3.6.1.2.1.15.7.1 bgpEstablished The BGP Established event is generated when the BGP FSM enters the ESTABLISHED state. Establishment of adjacency with BGP Event alarm Warning $1: Alarm OID $2: IP address of the peer neighbor $3: Record of last break of adjacency $4: Status of the current neighbor Service quality alarm

II. Trigger action


Adjacency with BGP is set up successfully.

III. Recommended action


This alarm informs the user of the successful setup of adjacency with BGP. The user does not need to clear the alarm.

IV. Related alarm message


Item Related alarm Relationship Relation degree Cause Description bgpBackwardTransition: 1.3.6.1.2.1.15.7.2 bgpEstablished 1.3.6.1.2.1.15.7.1 Prossible After the BGP adjacency is set up, when the BGP status changes toward lower status, Related alarm messagebgpBackwardTransition: 1.3.6.1.2.1.15.7.2 appears.

2.2.2 bgp/1/Trap4: 1.3.6.1.2.1.15.7.2


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Description BGP FSM moves from a higher numbered state to a lower numbered state [oid] BgpPeerRemoteAddr = [ipaddr] BgpPeerLastError = [octet] BgpPeerState = [integer] 1.3.6.1.2.1.15.7.2 bgpBackwardTransition The BGPBackwardTransition Event is generated when the BGP FSM moves from a higher numbered state to a lower numbered state. The BGP FSM moves from the higher numbered state to the lower numbered state. 2-2

H3C S9500 Trap Message Item Alarm type Alarm level Alarm parameter Function type Event alarm Warning $1: Alarm OID $2: IP address of the peer neighbor $3: Record of last break of adjacency $4: State of the current neighbor Service quality alarm Description

Trap Messages

II. Trigger action


This alarm message is sent when the BGP neighbor state changes from the higher numbered state to the lower numbered state. State relationship: IDLE(1)<CONNECT(2)<ACTIVE(3)<OPENSENT(4)<OPENCONFIRM(5)<ESTABLIS HED(6)

III. Recommended action


This alarm message informs the user of the change to the BGP adjacency. If it is caused by the link state, check the links.

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

bgpEstablished 1.3.6.1.2.1.15.7.1
bgpEstablished 1.3.6.1.2.1.15.7.1 Prossible After the BGP adjacency is set up, when BGP changes to the lower numbered state, Related alarm messagebgpBackwardTransition: 1.3.6.1.2.1.15.7.2 appears.

2.3 LDP
2.3.1 LDP/5/TRAP: 1.3.6.1.4.1.2011.5.12.2.2.0.15
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Description [oid] LDP Session [integer] [integer] [integer] [integer] [octet] Changes to Up 1.3.6.1.4.1.2011.5.12.2.2.0.15 hwMplsLdpSessionUpEventFailure Generation of this trap occurs when the value of hwMplsLdpSessionState enters the operational (5) state. The LDP session is set up. Event alarm Major $1: Alarm OID $2: LDP case ID, 0 at the moment $3: Interface index, 0 at the moment $4: Peer index, 0 at the moment $5: Session index, 0 at the moment $6: Session ID, LSR ID of the Peer

Alarm parameter

2-3

H3C S9500 Trap Message Item Function type Communication alarm Description

Trap Messages

II. Trigger action


This alarm is triggered because: The LDP session is set up.

III. Recommended action


None

IV. Related alarm message


LDP/5/TRAP: 1.3.6.1.4.1.2011.5.12.2.2.0.16

2.3.2 LDP/5/TRAP: 1.3.6.1.4.1.2011.5.12.2.2.0.16


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Description [oid] LDP Session [integer] [integer] [integer] [integer] [octet] Changes to Down 1.3.6.1.4.1.2011.5.12.2.2.0.16 hwMplsLdpSessionDownEventFailure Generation of this trap occurs when the value of hwMplsLdpSessionState leaves the operational (5) state. The LDP session is disconnected. Event alarm Major $1: Alarm OID $2: LDP case ID, 0 at the moment $3: Interface index, 0 at the moment $4: Peer index, 0 at the moment $5: Session index, 0 at the moment $6: Session ID, LSR ID of the Peer Communication alarm

Alarm parameter

Function type

II. Trigger action


This alarm has the following trigger actions: The session setup interface fails; Related configurations have been deleted. For example, the LDP or MPLS is disabled.

III. Recommended action


Based on the cause, the recommended actions include: If the session setup interface fails, recover the session by finding and clearing the interface fault; If related configurations have been deleted, restore related configurations to re-set up the LSP.

2-4

H3C S9500 Trap Message

Trap Messages

IV. Related alarm message


LDP/5/TRAP: 1.3.6.1.4.1.2011.5.12.2.2.0.15

2.4 LSPM
2.4.1 LSPM/5/TRAP: 1.3.6.1.2.1.10.166.2.0.1
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [oid] LSP [integer] Changes to Up 1.3.6.1.2.1.10.166.2.0.1 mplsXCUp This notification is generated when a mplsXCOperStatus object for one of the configured cross-connect entries is about to leave the down state and transition into some other state (but not into the notPresent state). This other state is indicated by the included value of mplsXCOperStatus. The LSP is set up. Event alarm Major $1: Alarm OID $2: LSP index Communication alarm

II. Trigger action


This alarm has the following trigger action: The LSP is set up.

III. Recommended action


None

IV. Related alarm message


LSPM/5/TRAP: 1.3.6.1.2.1.10.166.2.0.2

2.4.2 LSPM/5/TRAP: 1.3.6.1.2.1.10.166.2.0.2


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [oid] LSP [integer] Changes to Down 1.3.6.1.2.1.10.166.2.0.2 mplsXCDown This notification is generated when an mplsXCOperStatus object for one of the configured cross-connect entries is about to enter the down state from some other state (but not from the notPresent state). This other state is indicated by the included value of mplsXCOperStatus. The LSP is removed. Event alarm Major $1: Alarm OID $2: LSP index Communication alarm 2-5

H3C S9500 Trap Message

Trap Messages

II. Trigger action


This alarm has the following trigger actions: The LDP session is disconnected; The LSP setup policy is changed; The route is changed. The route related to this LSP is removed or changed in the next jump; Related configurations have been deleted. For example, the LDP or MPLS is disabled.

III. Recommended action


Based on the cause, the recommended actions include: If the LDP session is disconnected, locate the cause by viewing the link state and related configurations, and recover the session; If the LSP setup policy is changed, restore the policy by using the lsp-trigger command in the MPLS view; If the route is changed, restore the route to re-set up the LSP; If related configurations have been deleted, restore related configurations to re-set up the LSP.

IV. Related alarm message


LSPM/5/TRAP: 1.3.6.1.2.1.10.166.2.0.1

2.5 OSPF
2.5.1 OSPF/1/ Trap1: 1.3.6.1.2.1.14.16.2.1
I. Basic information
Item Description OSPF virtual link state changed [oid] VirIfAreaId = [ipaddr] VirIfNbrId = [ipaddr] RouterId = [ipaddr] VirIfState = [integer] 1.3.6.1.2.1.14.16.2.1 ospfVirtIfStateChange An ospfIfStateChange trap signifies that there has been a change in the state of an OSPF virtual interface. This trap should be generated when the link state regresses (e.g., goes from Point-to-Point to Down) or progresses to a terminal state (i.e., Point-to-Point). The state of the link on an OSPF virtual interface changes. Event alarm Warning $1:Alarm OID $2: Area ID of the virtual interface $3: Neighbor router of the virtual interface $4: Local router $5: Virtual link state

Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter

2-6

H3C S9500 Trap Message Item Function type Service quality alarm Description

Trap Messages

II. Trigger action


Possible causes of the state change of the link on an OSPF virtual interface include: Normal state change. For example, the OSPF virtual interface serves as the Designated Router (DR); The link state on an interface changes. For example, the link is set to Down.

III. Recommended action


If the alarm is caused by an link state change on the interface, find the cause of the change: if the link state is changed to Down through the command line, recover the state through the command Undo Shutdown on this interface; if the hardware on the interface fails, change the faulty hardware; if the peer interface fails, clear the fault.

IV. Related alarm message


None

2.5.2 OSPF/1/Trap2: 1.3.6.1.2.1.14.16.2.2


I. Basic information
Item Description OSPF neighbour state changed [oid] NbrIpAddress = [ipaddr] NbrAddrLessIndex = [integer] RouterId = [ipaddr] NbrRouterId = [ipaddr] NbrState = [integer] 1.3.6.1.2.1.14.16.2.2 ospfNbrStateChange An ospfNbrStateChange trap signifies that there has been a change in the state of a non-virtual OSPF neighbor. This trap should be generated when the neighbor state regresses (e.g., goes from Attempt or Full to 1-Way or Down) or progresses to a terminal state (e.g., 2-Way or Full). When a neighbor transitions from or to Full on non-broadcast multi-access and broadcast networks, the trap should be gen-erated by the designated router. A designated router transitioning to Down will be noted by ospfIfStateChange. The state of an OSPF neighbor changes. Event alarm Warning $1: Alarm OID $2: IP address of the neighbor $3: No address interface index in the neighbor $4: Local router $5: Neighbor router $6: Neighbor state Service quality alarm

Alarm message

Alarm OID Alarm name Description Meaning Alarm type Alarm level

Alarm parameter

Function type

II. Trigger action


Possible causes of the state change of an OSPF neighbor include:

2-7

H3C S9500 Trap Message

Trap Messages

The OSPF neighbor state changes from the lower numberd state to the higher numbered state, that is, normal setup of adjacency; The OSPF neighbor state changes from the higher numbered state to the lower numbered state, that is, abnormal adjacency.

III. Recommended action


No alarm recovery is needed when the OSPF adjacency is set up normally; When the OSPF neighbor changes from the higher numbered state to the lower numbered state, the user should check for abnormal link state. If there is no abnormal link state, check whether the peer neighbor normally sends the Hello packet.

IV. Related alarm message


None

2.5.3 OSPF/1/ Trap3: 1.3.6.1.2.1.14.16.2.3


I. Basic information
Item Description OSPF virtual neighbour state changed [oid] VirNbrAreaId = [ipaddr] VirNbrRtrId = [ipaddr] RouterId = [ipaddr] VirNbrState = [integer] 1.3.6.1.2.1.14.16.2.3 ospfVirtNbrStateChange An ospfIfStateChange trap signifies that there has been a change in the state of an OSPF vir-tual neighbor. This trap should be generated when the neighbor state regresses (e.g., goes from Attempt or Full to 1-Way or Down) or progresses to a terminal state (e.g., Full). The state of an OSPF virtual neighbor changes. Event alarm Warning $1: Alarm OID $2: Area ID of the virtual link $3: Neighbor router of the virtual link $4: Local router $5: Neighbor state of the virtual link Service quality alarm

Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type

II. Trigger action


Possible causes of the change to the state of an OSPF virtual neighbor include: The OSPF neighbor state changes from the lower numbered state to the higher numbered state, that is, normal setup of adjacency; The OSPF neighbor state changes from the higher numbered state to the lower numbered state, that is, abnormal setup of adjacency.

2-8

H3C S9500 Trap Message

Trap Messages

III. Recommended action


No alarm recovery is needed when the OSPF adjacency is set up normally; When the OSPF neighbor changes from the higher numbered state to the lower numbered state, the user should check for abnormal link state. If there is no abnormal link state, check further whether the peer neighbor normally sends the report.

IV. Related alarm message


None

2.5.4 OSPF/1/ Trap4: 1.3.6.1.2.1.14.16.2.4


I. Basic information
Item Description OSPF interface configuration error IfIpAddress = [ipaddr] IfAddrLessIndex = [integer] RouterId = [ipaddr] PacketSrc = [ipaddr] ErrorType = [integer] PacketType = [integer] 1.3.6.1.2.1.14.16.2.4 ospfIfConfigError An ospfIfConfigError trap signifies that a packet has been received on a non-virtual interface from a router whose configuration parameters conflict with this router's configuration parameters. Note that the event op-tionMismatch should cause a trap only if it prevents an adjacency from forming. OSPF interface configurations conflict. Event alarm Warning $1: Alarm OID $2: IP address of the interface $3: No address interface index $4: Local router $5: Packet source address $6: Error type $7: Packet type Service quality alarm

Alarm message

Alarm OID Alarm name Description Meaning Alarm type Alarm level

Alarm parameter

Function type

II. Trigger action


The local terminal is not a vlan interface. The parameter configurations on both interfaces are different. In this case, the adjacency cannot be normally set up. The inconsistency of parameter configuration includes: OSPF version numbers, region configurations, network mask configurations, time settings of Hello packet timer, and time settings of the Dead timer.

III. Recommended action


Check whether the configurations mentioned earlier are the same.

2-9

H3C S9500 Trap Message

Trap Messages

IV. Related alarm message


None

2.5.5 OSPF/1/ Trap5: 1.3.6.1.2.1.14.16.2.5


I. Basic information
Item Description OSPF virtual interface configuration error [oid] VirIfAreaId = [ipaddr] VirIfNbrId = [ipaddr] RouterId = [ipaddr] ErrorType = [integer] PacketType = [integer] \r\n 1.3.6.1.2.1.14.16.2.5 ospfVirtIfConfigError An ospfConfigError trap signifies that a packet has been received on a virtual interface from a router whose configuration parameters conflict with this routers configuration parameters. Note that the event optionMismatch should cause a trap only if it prevents an adjacency from forming. OSPF virtual link interface configurations conflict. Event alarm Warning $1: Alarm OID $2: Area ID of the virtual interface $3: Neighbor router of the virtual link $4: Local router $5: Error type $6: Packet type Service quality alarm

Alarm message

Alarm OID Alarm name Description Meaning Alarm type Alarm level

Alarm parameter

Function type

II. Trigger action


The local terminal is not a vlan interface. The parameter configurations on both interfaces are not the same. The inconsistency of parameter configuration includes: OSPF version numbers, region configurations, network mask configurations, time settings of Hello packet timer, and time settings of the Dead timer.

III. Recommended action


Check whether the configurations mentioned earlier are the same.

IV. Related alarm message


None

2-10

H3C S9500 Trap Message

Trap Messages

2.5.6 OSPF/1/ Trap6: 1.3.6.1.2.1.14.16.2.6


I. Basic information
Item Description OSPF interface authentication failure [oid] IfIpAddress = [ipaddr] IfAddrLessIndex = [integer] RouterId = [ipaddr] PacketSrc = [ipaddr] ErrorType = [integer] PacketType = [integer] 1.3.6.1.2.1.14.16.2.6 ospfIfAuthFailure An ospfIfAuthFailure trap signifies that a packet has been received on a non-virtual in-terface from a router whose authentication key or authentication type conflicts with this router's authentication key or authentication type. The OSPF interface authentication fails. Event alarm Warning $1: Alarm OID $2: IP address of the interface $3: Local address interface index $4: Local router $5: Packet source address $6: Error type $7: Packet type Service quality alarm

Alarm message

Alarm OID Alarm name Description Meaning Alarm type Alarm level

Alarm parameter

Function type

II. Trigger action


Authentication configurations on both interfaces are not the same.

III. Recommended action


Check configurations of the authentication type and key on both interfaces. Set the types and keys to the same.

IV. Related alarm message


None

2.5.7 OSPF/1/ Trap7: 1.3.6.1.2.1.14.16.2.7


I. Basic information
Item Description OSPF virtual interface authentication failure [oid] VirIfAreaId = [ipaddr] VirIfNbrId = [ipaddr] RouterId = [ipaddr] ErrorType = [integer] PacketType = [integer] 1.3.6.1.2.1.14.16.2.7 ospfVirtIfAuthFailure

Alarm message

Alarm OID Alarm name

2-11

H3C S9500 Trap Message Item Description Meaning Alarm type Alarm level Description

Trap Messages

Alarm parameter

Function type

An ospfVirtIfAuthFailure trap signifies that a packet has been received on a virtual interface from a router whose authentication key or au-thentication type conflicts with this router's authentication key or authentication type. The OSPF virtual link interface authentication fails. Event alarm Warning $1: Alarm OID $2: Area ID of the virtual interface $3: Neighbor router of the virtual interface $4: Local router $5: Error type $6: Packet type Service quality alarm

II. Trigger action


Authentication keys on both interfaces are not the same.

III. Recommended action


Check the authentication types and keys on both interfaces. Set the types and keys to the same.

IV. Related alarm message


None

2.5.8 OSPF/1/ Trap8: 1.3.6.1.2.1.14.16.2.8


I. Basic information
Item Description OSPF interface received wrong packet [oid] IfIpAddress = [ipaddr] IfAddrLessIndex = [integer] RouterId = [ipaddr] PacketSrc = [ipaddr] PacketType = [integer] 1.3.6.1.2.1.14.16.2.8 ospfIfRxBadPacket An ospfIfRxBadPacket trap signifies that an OSPF packet has been received on a non-virtual interface that cannot be parsed. The OSPF interface receives a wrong packet. Event alarm Warning $1: Alarm OID $2: IP address of the interface $3: No address interface index $4: Local router $5: Packet source address $6: Packet type Service quality alarm

Alarm message

Alarm OID Alarm name Description Meaning Alarm type Alarm level

Alarm parameter

Function type

2-12

H3C S9500 Trap Message

Trap Messages

II. Trigger action


The local termination is not a vlan interface. It receives a bad packet. Bad packets include: packets with wrong types, IP addresses, or protocols, packets from an unknown neighbor, small bad packets, large bad packets, checksum error, Router ID conflict in Hello packets, Router ID conflict in DD packets, neighbor state errors in DD, LSA update, LSA request, or LSA confirmation packets, and empty LSA request packets.

III. Recommended action


Check whether the configuration on the related neighbor at this interface is correct, or whether there is an aggressive packet.

IV. Related alarm message


None

2.5.9 OSPF/1/ Trap9: 1.3.6.1.2.1.14.16.2.9


I. Basic information.
Item Description OSPF virtual interface received wrong packet [oid] VirIfAreaId = [ipaddr] VirIfNbrId = [ipaddr] RouterId = [ipaddr] PacketType = [integer] 1.3.6.1.2.1.14.16.2.9 OspfVirtIfRxBadPacket An ospfRxBadPacket trap signifies that an OSPF packet has been received on a virtual interface that cannot be parsed. The OSPF virtual link interface receives a wrong packet. Event alarm Warning $1: Alarm OID $2: Area ID of the virtual interface $3: Neighbor router of the virtual interface $4: Local router $5: Local router Service quality alarm

Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type

II. Trigger action


The local termination is a vlan interface. It receives a bad packet. Bad packets include: packets with wrong types, IP addresses, or protocols, packets from an unknown neighbor, small bad packets, large bad packets, checksum error, Router ID conflict in Hello packets, Router ID conflict in DD packets, neighbor state errors in DD, LSA update, LSA request, or LSA confirmation packets, and empty LSA request packets.

2-13

H3C S9500 Trap Message

Trap Messages

III. Recommended action


Check whether the configuration on the related neighbor at this interface is correct, or whether there is an aggressive packet.

IV. Related alarm message


None

2.5.10 OSPF/1/ Trap10: 1.3.6.1.2.1.14.16.2.10


I. Basic information
Item Description OSPF interface retransmitted packet [oid] IfIpAddress = [ipaddr] IfAddrLessIndex = [integer] NbrIpAddress = [ipaddr] NbrAddrLessIndex = [integer] LsdbAreaId = [ipaddr] LsdbType = [integer] LsdbLsid = [ipaddr] LsdbRouterId = [ipaddr] RouterId = [ipaddr] NbrRouterId = [ipaddr] PacketType = [integer] 1.3.6.1.2.1.14.16.2.10 ospfTxRetransmit An ospfTxRetransmit trap signifies that an OSPF packet has been retransmitted on a non-virtual interface. All packets that may be re-transmitted are associated with an LSDB entry. The LS type, LS ID, and Router ID are used to identify the LSDB entry. The OSPF interface retransmits a packet. Event alarm Warning $1: Alarm OID $2: IP address of the interface $3: No address interface index $4: IP address of the neighbor $5: No address interface index in the neighbor $6: LSA area ID $7: LSA type $8: LSA ID $9: LSA release router $10: Local router $11: Neighbor router $12: Packet type Service quality alarm

Alarm message

Alarm OID Alarm name Description Meaning Alarm type Alarm level

Alarm parameter

Function type

II. Trigger action


The local terminal is a non-virtual interface. When it does not receive the confirmation packet of a related LSA within the configured time, it retransmits the LSA.

III. Recommended action


None

2-14

H3C S9500 Trap Message

Trap Messages

IV. Related alarm message


None

2.5.11 OSPF/1/ Trap11: 1.3.6.1.2.1.14.16.2.11


I. Basic information
Item Description OSPF virtual interface retransmitted packet [oid] VirIfAreaId = [ipaddr] VirIfNbrId = [ipaddr] LsdbAreaId = [ipaddr] LsdbType = [integer] LsdbLsid = [ipaddr] LsdbRouterId = [ipaddr] RouterId = [ipaddr] PacketType = [integer] 1.3.6.1.2.1.14.16.2.11 ospfVirtIfTxRetransmit An ospfTxRetransmit trap signifies than an OSPF packet has been retransmitted on a virtual interface. All packets that may be retransmit-ted are associated with an LSDB entry. The LS type, LS ID, and Router ID are used to identify the LSDB entry. The link of the OSPF virtual interface retransmits a packet. Event alarm Warning $1: Alarm OID $2: Area ID of the virtual interface $3: Neighbor router of the virtual interface $4: LSA area ID $5: LSA type $6: LSA ID $7: LSA release router $8: Local router $9: Packet type Service quality alarm

Alarm message

Alarm OID Alarm name Description Meaning Alarm type Alarm level

Alarm parameter

Function type

II. Trigger action


The local terminal is a virtual interface. When it does not receive the confirmation packet of a related LSA within the configured time, it retransmits the LSA.

III. Recommended action


None

IV. Related alarm message


None

2-15

H3C S9500 Trap Message

Trap Messages

2.5.12 OSPF/1/ Trap12: 1.3.6.1.2.1.14.16.2.12


I. Basic information
Item Description OSPF (re)originated LSA [oid] LsdbAreaId = [ipaddr] LsdbType = [integer] LsdbLsid = [ipaddr] LsdbRouterId = [ipaddr] RouterId = [ipaddr] 1.3.6.1.2.1.14.16.2.12 ospfOriginateLsa An ospfOriginateLsa trap signifies that a new LSA has been originated by this router. The OSPF (re-)generates an LSA. Event alarm Warning $1: Alarm OID $2: LSA area ID $3: LSA type $4: LSA ID $5: LSA release router $6: Local router Service quality alarm

Alarm message

Alarm OID Alarm name Description Meaning Alarm type Alarm level

Alarm parameter

Function type

II. Trigger action


When a new router is added in a network, a router LSA is generated in the area of the router; When the DR in a network segment changes, or a new router is placed in the segment, the DR generates a network LSA; When there is a change to the link state in the area where the Area Border Router (ABR) locates, a new network summary LSA is generated; When there is a change to the Autonomous System Border Router (ASBR) in the area where the ABR locates, a new network summary LSA is generated; When there is a change to the external route imported by the ASBR, a new ASE LSA is generated; When there is a change to the external route brought to the NSSA area, the router that brings this external route generates a new NSSA LSA; All situations stated above lead to this alarm message.

III. Recommended action 1) Check whether a cable was wrongly connected or disconnected before the alarm message; 2) 3) Check whether there is a new router in the network; Check whether there is a router removed from the network;

2-16

H3C S9500 Trap Message

Trap Messages

4) 5)

Check whether the interface of a router fails; Check whether there is a change to the external route brought to the network.

IV. Related alarm message


None

2.5.13 OSPF/1/ Trap13: 1.3.6.1.2.1.14.16.2.13


I. Basic information
Item Description OSPF LSA reached max-age [oid] LsdbAreaId = [ipaddr] LsdbType = [integer] LsdbLsid = [ipaddr] LsdbRouterId = [ipaddr] RouterId = [ipaddr] 1.3.6.1.2.1.14.16.2.13 ospfMaxAgeLsa An ospfMaxAgeLsa trap signifies that one of the LSA in the router's link-state database has aged to MaxAge. The OSPF LSA reaches the max age. Event alarm Warning $1: Alarm OID $2: LSA area ID $3: LSA type $4: LSA ID $5: LSA release router $6: Local router Service quality alarm

Alarm message

Alarm OID Alarm name Description Meaning Alarm type Alarm level

Alarm parameter

Function type

II. Trigger action


The neighbor state changes. The neighbor cannot send new packets. The router that generated this LSA fails and cannot generate new LSAs. There is a change to the router that generated this LSA. For example, the DR changes.

III. Recommended action


1) 2) 3) Check whether a wrong configuration existed or a cable was wrongly connected or disconnected before the alarm message is generated; Check whether there is a change to the link state of the router that generated this LSA; Check the ID of the router that generated this LSA. For example, if the category-3 LSA generates an alarm message, check whether the related router is still an ABR; if the category-2 LSA generates an alarm message, check whether the related router is still a DR;

2-17

H3C S9500 Trap Message

Trap Messages

4) 5)

Check whether there is a change to the neighbor state; Check whether the link of a router fails.

IV. Related alarm message


None

2.5.14 OSPF/1/ Trap14: 1.3.6.1.2.1.14.16.2.14


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description OSPF number of LSAs exceeded ExtLsdbLimit [oid] RouterId = [ipaddr] ExtLsdbLimit = [integer] 1.3.6.1.2.1.14.16.2.14 ospfLsdbOverflow An ospfLsdbOverflow trap signifies that the number of LSAs in the router's link-state database has exceeded ospfExtLsdbLimit. The OSPF LSA number reaches ExtLsdbLimit. Event alarm Warning $1: Alarm OID $2: Local router $3: ExtLsdbLimit Service quality alarm

II. Trigger action


There are excessive routers, resulting in excessive router LSAs in the area; Routes in category-3 LSAs that can be aggregated are not converged, resulting in excessive category-3 LSAs; There are excessive external routes brought to the network, resulting in excessive category-5 LSAs.

III. Recommended action


This is the normal warning in the protocol, and requires no processing.

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

OSPF/1/ Trap15: 1.3.6.1.2.1.14.16.2.15


ospfLsdbApproachingOverflow Prossible If the number of LSAs increases to ExtLsdbLimit after the ospfLsdbApproachingOverflow alarm, this alarm message appears.

2-18

H3C S9500 Trap Message

Trap Messages

2.5.15 OSPF/1/ Trap15: 1.3.6.1.2.1.14.16.2.15


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description OSPF number of LSAs exceeded 90%% ExtLsdbLimit [oid] RouterId = [ipaddr] ExtLsdbLimit = [integer] 1.3.6.1.2.1.14.16.2.15 ospfLsdbApproachingOverflow An ospfLsdbApproachingOverflow trap signifies that the number of LSAs in the router's linkstate database has exceeded ninety percent of ospfExtLsdbLimit. The OSPF LSA number reaches 90% of ExtLsdbLimit. Event alarm Warning $1: Alarm OID $2: Local router $3: ExtLsdbLimit Service quality alarm

II. Trigger action


There are excessive routers, resulting in excessive router LSAs in the area; Routes in category-3 LSAs that can be aggregated are not converged, resulting inexcessive category-3 LSAs; There are excessive external routes brought to the network, resulting in excessive category-5 LSAs.

III. Recommended action


This is the normal prompt message in the protocol, and requires no processing.

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

OSPF/1/ Trap14: 1.3.6.1.2.1.14.16.2.14


ospfLsdbApproachingOverflow Prossible If the number of LSAs continues to increase to ExtLsdbLimit after this alarm, the ospfLsdbApproachingOverflow alarm message appears.

2.5.16 OSPF/1/ Trap16: 1.3.6.1.2.1.14.16.2.16


I. Basic information
Item OSPF link state changed [oid] IfIpAddress = [ipaddr] IfAddrLessIndex = [integer] RouterId = [ipaddr] IfState = [integer] 1.3.6.1.2.1.14.16.2.16 Description

Alarm message Alarm OID

2-19

H3C S9500 Trap Message Item Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description

Trap Messages

ospfIfStateChange An ospfIfStateChange trap signifies that there has been a change in the state of a non-virtual OSPF interface. This trap should be generated when the link state regresses (e.g., goes from Dr to Down) or progresses to a terminal state (i.e., Point-to-Point, DR Other, Dr, or Backup). The OSPF link state changes. Event alarm Warning $1:Alarm OID $2: IP address of the interface $3: Router ID of the OSPF $4: Interface state Service quality alarm

II. Trigger action


Possible causes of the state change of an OSPF interface include: Normal state change. For example, when the OSPF interface serves as the DR; The link state changes. For example, the link state is set to Down.

III. Recommended action


Normal change to the OSPF link state does not require recovery. If the alarm message is caused by a change of link state on the interface, find the cause of the change: If the link state is changed to Down through the command line, recover the state through the command Undo Shutdown on this interface; If the hardware on the interface fails, change the hardware; If the peer interface fails, clear the fault.

IV. Related alarm message


None

2.6 MSTP
2.6.1 MSTP/2/ ROOT: 1.3.6.1.4.1.2011.2.23.1.14.0.3
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [OID]: We are not the root switch of the instance [INTEGER]! 1.3.6.1.4.1.2011.2.23.1.14.0.3 hwBridgeLostRootPrimary The SNMP trap that is generated when the bridge is no longer the root bridge of the instance. Another switch with higher priority has already been the root bridge of the instance. The switch that has been configured as the root bridge of an instance receives a superior packet and becomes no longer the root bridge of the instance. Event alarm Major 1: hwdot1sInstanceID instance ID Environmental alarm

2-20

H3C S9500 Trap Message

Trap Messages

II. Trigger action


The equipment that has been configured as the root bridge of an instance receives the superior packet of this instance. If the local switch is configured as the root bridge of an instance, and another switch with a smaller MAC address is also configured as the root bridge of the instance, the second switch will preempt the root bridge of the local switch in the instance. In this case, the alarm is generated.

III. Recommended action


Check whether another switch is configured as the root bridge of the same instance. If so, change the configuration to ensure that only one switch is configured as the root bridge of one instance.

IV. Related alarm message


None

2.6.2 MSTP/2/ RGSUP: 1.3.6.1.4.1.2011.2.23.1.14.0.4


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [OID]: Instance [INTEGER]'s ROOT-Protection port [INTEGER].[INTEGER] received superior message! 1.3.6.1.4.1.2011.2.23.1.14.0.4 hwPortMstiRootGuarded The SNMP trap that is generated when a root-guard port receives a superior message on the relevant instance. The root-guard port receives a superior message. Event alarm Major 1: hwdot1sInstanceID instance ID 2: hwdot1sMstiPortIndex port Index Environmental alarm

II. Trigger action


For Root-protection ports, they can only be designated ports for instances. Once this port receives a configuration message with a higher priority from some instance, this alarm is generated. The port of this instance is set to interception state and does not transfer packets any more (that is, the links of this port are disconnected).When no configuration message with a higher priority is received in a considerable period of time, the port resumes the normal state.

III. Recommended action


Check where the packet with higher priority comes from and whether the configuration is wrong.

2-21

H3C S9500 Trap Message

Trap Messages

IV. Related alarm message


None

2.6.3 MSTP/2/ IVBPDU: 1.3.6.1.4.1.2011.2.23.1.14.0.5


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [OID]: BPDU-Protection port [INTEGER] received BPDU packet! 1.3.6.1.4.1.2011.2.23.1.14.0.5 hwPortMstiBpduGuarded The SNMP trap that is generated when an edged port of the BPDU-guard switch receives BPDU packets. A BPDU-protection edged port receives BPDU packets. Event alarm Major 1: dot1dStpPort port Index Environmental alarm

II. Trigger action


For the equipment at the access layer, the access ports are often directly connected to the user terminal (such as a PC) or file server. At this time, the access ports are set as an edged port to realize fast migration. When these ports receive a configuration message (BDPU packet), the system automatically sets these ports to non-edged ports, and re-calculates the Spanning Tree, leading to network topology storm. Under normal condition, these ports do not receive configuration messages of the Spanning Tree protocol. If a person forges configuration messages to attack the switch with malice, a network storm occurs. MSTP uses BPDU-protection to prevent such attacks. The BPDU-protection is enabled in the switch. Once the edged ports receive configuration messages, the system generates this alarm message and closes these ports. The closed ports can only be resumed by network administrators.

III. Recommended action


Edged ports are generally connected to a PC or file server. Hence they do not receive BPDU packets under normal condition.Check the source of the BPDU this port receives. Check whether this port is wrongly connected to a switch. Recover the port connection first, and then undo shutdown the port.

IV. Related alarm message


None

2-22

H3C S9500 Trap Message

Trap Messages

2.6.4 MSTP/2/ LGEXP: 1.3.6.1.4.1.2011.2.23.1.14.0.6


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [OID]: Instance [INTEGER]'s LOOP-Protection port [INTEGER].[INTEGER] did not receive message! 1.3.6.1.4.1.2011.2.23.1.14.0.6 hwPortMstiLoopGuarded The SNMP trap that is generated when an Alternate-Port or Root-Port is aged out. A root port or optional port times out when receiving a BPDU message. Event alarm Major 1: hwdot1sInstanceID instance ID 2: hwdot1sMstiPortIndex port Index Environmental alarm

II. Trigger action


The root port or optional port does not receive the BPDU packet from the upstream for a long time, leading to timeout of the port in receiving the BPDU message.

III. Recommended action


Check whether the upstream port normally sends a packet and whether the local port normally receives the packet.

IV. Related alarm message


None

2.7 POS
2.7.1 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.5
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [oid] LRDI Alarm on interface [INTEGER] 1.3.6.1.4.1.2011.10.2.19.2.0.5 h3cPosLRDIAlarm LRDI is used to return an indication to the transmit end that the received end has detected an incoming section defect or is receiving LAIS.LRDI is generated by inserting a 110 code in positions 6,7 and 8 of the K2 byte befor scrambing. LRDI is used to inform the transmission end of a serious link failure at the local end or of the event that the local end receives an LAIS. LRDI is generated by inserting 110 into bits 6, 7, and 8 in K2. Failure alarm Major $1: Alarm OID $2: Interface of the alarm Equipment alarm

2-23

H3C S9500 Trap Message

Trap Messages

II. Trigger action


The peer end has a serious link failure or receives an LAIS alarm message.

III. Recommended action


Check the links or peer configuration.

IV. Related alarm message


None

2.7.2 POS/2/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.2


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type [oid] LOF Alarm on interface [INTEGER] 1.3.6.1.4.1.2011.10.2.19.2.0.2 h3cPosLOFAlarm This alarm message indicates loss of frame. Frame alignment loss Failure alarm Major $1: Alarm OID $2: Interface of the alarm Equipment alarm Description

II. Trigger action


Bit errors occur in the links.

III. Recommended action


Check the links.

IV. Related alarm message


None

2.7.3 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.3


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter [oid] OOF Alarm on interface [INTEGER] 1.3.6.1.4.1.2011.10.2.19.2.0.3 h3cPosOOFAlarm Alarm indicates out of frame. Out of framed alignment. Failure alarm Major $1: Alarm OID $2: Interface of the alarm Description

2-24

H3C S9500 Trap Message Item Function type Equipment alarm Description

Trap Messages

II. Trigger action


Bit errors occur in the links.

III. Recommended action


Check the link connection.

IV. Related alarm message


None

2.7.4 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.6


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [oid] PRDI Alarm on interface [INTEGER] 1.3.6.1.4.1.2011.10.2.19.2.0.6 h3cPosPRDIAlarm PRDI is used to return an indication to the transmit STS PTE that the receiving STS PTE has detected an incoming STS Path defect.. PRDI is used to return an indication to the transmission STS PTE that the local STS PTE has detected a serious STS Path defect. Failure alarm Major $1: Alarm OID $2: Interface of the alarm Equipment alarm

II. Trigger action


An error occurs in the net load boren by the path layer or the path layers are not normally connected.

III. Recommended action


Check whether the path layers are configured in the same way at both ends, and whether the path layer connection is abnormal.

IV. Related alarm message


None

2.7.5 POS/2/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.1


I. Basic information
Item Alarm message [oid] LOS Alarm on interface [INTEGER] Description

2-25

H3C S9500 Trap Message Item Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type 1.3.6.1.4.1.2011.10.2.19.2.0.1 h3cPosLOSAlarm Alarm indicates loss of signal. A signal is lost. Failure alarm Major $1: Alarm OID $2: Interface of the alarm Equipment alarm Description

Trap Messages

II. Trigger action


The reception end cannot detect 01 transient within 20us.

III. Recommended action


1. Check the connection; 2. Check whether the scrambles at both ends are configured in the same way.

IV. Related alarm message


None

2.7.6 POS/2/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.8


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type [oid] LOP Alarm on interface [INTEGER] 1.3.6.1.4.1.2011.10.2.19.2.0.8 h3cPosLOPAlarm Alarm indicates loss of pointer. A pointer is lost. Failure alarm Major $1: Alarm OID $2: Interface of the alarm Equipment alarm Description

II. Trigger action


An LOP alarm message appears when 8 consecutive frames receive an invalid pointer or NDF.

III. Recommended action


1. Check clock configuration; 2. Check frame format configurations at both ends.

IV. Related alarm message


None

2-26

H3C S9500 Trap Message

Trap Messages

2.7.7 POS/2/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.4


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [oid] LAIS Alarm on interface [INTEGER] 1.3.6.1.4.1.2011.10.2.19.2.0.4 h3cPosLAISAlarm LAIS is used to indicate that a signal defect has been detected at a section terminating equipment. LAIS is detected by a 111 code in bits 6,7 and 8 of the K2 byte after unsrambing. The local end receives an LOS or LOF alarm message. Failure alarm Major $1: Alarm OID $2: Interface of the alarm Equipment alarm

II. Trigger action


The local end receives an LOS or LOF alarm message.

III. Recommended action


Check whether links are normally connected.

IV. Related alarm message


None

2.7.8 POS/2/ TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.7


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [oid] PAIS Alarm on interface [INTEGER] 1.3.6.1.4.1.2011.10.2.19.2.0.7 h3cPosPAISAlarm PAIS is generated by an LTE upon detection of an LOS, LOF, AIS-L, or LOP-P defect.. PAIS alarm message appears when the local end receives an LOS, LOF, AIS-L or LOP-P alarm message. Failure alarm Major $1: Alarm OID $2: Interface of the alarm Equipment alarm

II. Trigger action


The local end receives a serious alarm message such as LOS, LOF, AIS-L and LOP.

III. Recommended action


Check whether links are normally connected.

2-27

H3C S9500 Trap Message

Trap Messages

IV. Related alarm message


None

2.7.9 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.9


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [oid] STIM Alarm on interface [INTEGER] 1.3.6.1.4.1.2011.10.2.19.2.0.9 h3cPosSTIMAlarm Alarm indicates inconsistency between sent and received J0 bytes. The received J0 bytes are different from the expected. Failure alarm Major $1: Alarm OID $2: Interface of the alarm Equipment alarm

II. Trigger action


The received J0 bytes are different from the expected.

III. Recommended action


Check whether J0 bytes are configured in the same way at both ends.

IV. Related alarm message


None

2.7.10 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.10


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [oid] PTIM Alarm on interface [INTEGER] 1.3.6.1.4.1.2011.10.2.19.2.0.10 h3cPosPTIMAlarm Alarm indicates inconsistency between sent and received J1 bytes. The received J1 bytes are different from the expected. Failure alarm Major $1: Alarm OID $2: Interface of the alarm Equipment alarm

II. Trigger action


The received J1 bytes are different from the expected.

2-28

H3C S9500 Trap Message

Trap Messages

III. Recommended action


Check whether J1 bytes are configured in the same way at both ends.

IV. Related alarm message


None

2.7.11 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.11


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [oid] PSLM Alarm on interface [INTEGER] 1.3.6.1.4.1.2011.10.2.19.2.0.11 h3cPosPSLMAlarm Alarm indicates a mismatched C2 byte. The received C2 bytes are different from the expected. Failure alarm Major $1:Alarm OID $2: Interface of the alarm Equipment alarm

II. Trigger action


The received C2 bytes are different from the expected.

III. Recommended action


Check whether C2 bytes are configured in the same way at both ends.

IV. Related alarm message


None

2.7.12 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.12


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [oid] LSD Alarm on interface [INTEGER] 1.3.6.1.4.1.2011.10.2.19.2.0.12 h3cPosLSDAlarm Alarm indicates that the B2 bit-error rate exceeds SD threshold. The bit-error rate exceeds the SD threshold. Failure alarm Major $1: Alarm OID $2: Interface of the alarm Equipment alarm

2-29

H3C S9500 Trap Message

Trap Messages

II. Trigger action


The bit-error rate exceeds the SD threshold.

III. Recommended action


Check whether errors occur in the optical fiber and optical module.

IV. Related alarm message


None

2.7.13 POS/3/TRAP: 1.3.6.1.4.1.2011.10.2.19.2.0.13


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [oid] LSM Alarm on interface [INTEGER] 1.3.6.1.4.1.2011.10.2.19.2.0.13 h3cPosLSFAlarm Alarm indicates that the B2 bit-error rate exceeds SF threshold. The bit-error rate exceeds the SF threshold. Failure alarm Major $1: Alarm OID $2: Interface of the alarm Equipment alarm

II. Trigger action


The bit-error rate exceeds the SF threshold.

III. Recommended action


Check whether errors occur in the optical fiber and optical module.

IV. Related alarm message


None

2.8 VRRP
2.8.1 vrrp/5/TrapBecomeNewMaster: 1.3.6.1.2.1.68.0.1
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning [oid]become new master 1.3.6.1.2.1.68.0.1 vrrpTrapNewMaster A device become new master The device becomes the master virtual switch. Description

2-30

H3C S9500 Trap Message Item Alarm type Alarm level Alarm parameter Function type Event alarm Warning None Communication alarm Description

Trap Messages

II. Trigger action


1) When a new group of VRRP backup switches are set up, one switch will be designated as the master; 2) When the priority of a switch that was not the master switch is elevated to a level higher than the former master, this switch becomes the new master; 3) When the master switch fails, the switch in the backup group that has the highest priority becomes the master.

III. Recommended action


None

IV. Related alarm message


None

2.8.2 vrrp/4/ TrapAuthFailed: 1.3.6.1.2.1.68.0.2


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type [oid]failed to authenticate 1.3.6.1.2.1.68.0.2 vrrpTrapAuthFailure Virtual router anthtication failure,master and backup don not same The authentication passwords are different in the master and slave switches. Event alarm Warning None Communication alarm Description

II. Trigger action


The VRRP packet authentication passwords are different in the master and slave switches.

III. Recommended action


Set the authentication passwords in the master and slave switches to the same.

2-31

H3C S9500 Trap Message

Trap Messages

IV. Related alarm message


None

2.9 DEV
2.9.1 DEV/2/POWER STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.1
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: power ID is [INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.1 Powerfailure Equipment power failure. The alarm appears when the power is just inserted to the equipment or some power in the equipment fails. The power fails. Failure alarm Major $1: OID $2: Power ID Equipment alarm

II. Trigger action


The power fails.

III. Recommended action


Replace the power.

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description DEV/2/ POWER STATE CHANGE TO NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.2 DEV/2/ POWER STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.1 Certain The related alarm is the recovery alarm. If this fault is recovered, the related alarm appears. If the fault is not recovered, this related alarm does not appear.

2.9.2 DEV/2/POWER STATE CHANGE TO NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.2


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Description Trap [OID]: power ID is [INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.2 hwPowerNormal This alarm message appears when the power state turns normal. The power is normal. Recovery alarm

2-32

H3C S9500 Trap Message Item Alarm level Alarm parameter Function type Major $1: OID $2: Power ID Equipment alarm Description

Trap Messages

II. Trigger action


The power recovers.

III. Recommended action


None

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

DEV/2/ POWER STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.1


DEV/2/ POWER STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.1 Certain This alarm message may appear only after the related alarm is generated.

2.9.3 DEV/2/POWER REMOVED: 1.3.6.1.4.1.2011.2.23.1.12.1.5


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: power ID is [INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.5 hwPowerRemoved This alarm message appears when the power is removed. The power is removed. Event alarm Major $1:OID $2: Power ID Equipment alarm

II. Trigger action


The power is removed.

III. Recommended action


Insert the power.

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

DEV/2/ POWER INSERT: 1.3.6.1.4.1.2011.2.23.1.12.1.23


DEV/2/ POWER REMOVED: 1.3.6.1.4.1.2011.2.23.1.12.1.5 Certain The related alarm is the recovery alarm. 2-33

H3C S9500 Trap Message

Trap Messages

2.9.4 DEV/2/FAN STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.6


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: fan ID is [INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.6 Fanfailure This alarm message appears when the fan fails. The fan fails. Failure alarm Major $1: OID $2: Fan ID Equipment alarm

II. Trigger action


The fan fails.

III. Recommended action


Change the fan.

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

DEV/2/ FAN STATE CHANGE TO NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.7


DEV/2/ FAN STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.6 is the root alarm. Certain The related alarm is the recovery alarm.

2.9.5 DEV/2/FAN STATE CHANGE TO NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.7


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: fan ID is [INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.7 hwFanNormal This alarm message appears when the fan recovers from a failure. The fan recovers from a failure. Recovery alarm Major $1: OID $2: Fan ID Equipment alarm

II. Trigger action


The fan recovers from a failure.

2-34

H3C S9500 Trap Message

Trap Messages

III. Recommended action


None

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

DEV/2/ FAN STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.6


DEV/2/ FAN STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.6 is the root alarm. Certain This alarm only appears when the fan recovers from a failure.

2.9.6 DEV/2/BOARD REMOVED: 1.3.6.1.4.1.2011.2.23.1.12.1.8


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: frameIndex is [INTEGER], slotIndex [INTEGER].[INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.8 hwBoardRemoved This alarm message appears when a board is removed. A board is removed. Event alarm Major $1: OID $2: Frame No. $3: Frame No. $4: Slot No. Equipment alarm

II. Trigger action


A board is removed.

III. Recommended action


None

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

DEV/2/ BOARD INSERTED: 1.3.6.1.4.1.2011.2.23.1.12.1.9


DEV/2/ BOARD REMOVED: 1.3.6.1.4.1.2011.2.23.1.12.1.8 is the root alarm. Certain The related alarm is the recovery alarm.

2-35

H3C S9500 Trap Message

Trap Messages

2.9.7 DEV/2/BOARD INSERTED: 1.3.6.1.4.1.2011.2.23.1.12.1.9


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: frameIndex is [INTEGER], slotIndex [INTEGER].[INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.9 hwBoardInserted This alarm message appears when a board is inserted. A board is inserted. Event alarm Major $1: OID $2: Frame No. $3: Frame No. $4: Slot No. Equipment alarm

II. Trigger action


A board is inserted.

III. Recommended action


None

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

DEV/2/ BOARD REMOVED: 1.3.6.1.4.1.2011.2.23.1.12.1.8


DEV/2/ BOARD REMOVED: 1.3.6.1.4.1.2011.2.23.1.12.1.8 is the root alarm. Certain This alarm may appear after the related alarm is generated.

2.9.8 DEV/2/BOARD STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.10


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: frameIndex is [INTEGER], slotIndex [INTEGER].[INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.10 hwBoardFailure This alarm message appears when the board fails. The board fails. Failure alarm Critical $1: OID $2: Frame No. $3: Frame No. $4: Slot No. Equipment alarm

2-36

H3C S9500 Trap Message

Trap Messages

II. Trigger action


1) 2) The user reboots the system; Abnormal boards are automatically rebooted.

III. Recommended action


Determine the reasons and whether the boards can be normally started.

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

DEV/2/BOARD STATE CHANGE TO NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.11


DEV/2/ BOARD STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.10 is the root alarm. Certain The related alarm is the recovery alarm.

2.9.9 DEV/2/BOARD STATE CHANGE TO NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.11


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: frameIndex is [INTEGER], slotIndex [INTEGER].[INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.11 hwBoardNormal This alarm message appears when the boards recovers from failure. The board recovers from failure. Recovery alarm Major $1: OID $2: Frame No. $3: Frame No. $4: Slot No. Equipment alarm

II. Trigger action


The board recovers from failure.

III. Recommended action


None

IV. Related alarm message


Item Related alarm message Relationship Description

DEV/2/ BOARD STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.10


DEV/2/ BOARD STATE CHANGE TO FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.10 is the root alarm.

2-37

H3C S9500 Trap Message Item Relation degree Cause Description Certain This alarm message may appear only after the related alarm is generated.

Trap Messages

2.9.10 DEV/2/BOARD TEMPERATURE LOWER: 1.3.6.1.4.1.2011.2.23.1.12.1.14


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: frameIndex is [INTEGER], slotIndex [INTEGER].[INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.14 hwBoaardTemperatureLower This alarm message appears when the the board temperature is below the normal value. The board temperature is too low. Failure alarm Major $1: OID $2: Frame No. $3: Frame No. $4: Slot No. Environmental alarm

II. Trigger action


The board temperature is too low.

III. Recommended action


Elevate the temperature.

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

DEV/2/ BOARD TEMPERATURE NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.15


DEV/2/ BOARD TEMPERATURE LOWER: 1.3.6.1.4.1.2011.2.23.1.12.1.14 Certain The related alarm is the recovery alarm.

2.9.11 DEV/2/BOARD TEMPERATURE NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.15


I. Basic information
Item Alarm message Alarm OID Alarm name Description Description Trap [OID]: frameIndex is [INTEGER], slotIndex [INTEGER].[INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.15 hwBoaardTemperatureFromLowerToNormal This alarm message appears when the the board temperature turns to the normal value.

2-38

H3C S9500 Trap Message Item Meaning Alarm type Alarm level Alarm parameter Function type The board temperature becomes normal. Recovery alarm Major $1: OID $2: Frame No. $3: Frame No. $4: Slot No. Environmental alarm Description

Trap Messages

II. Trigger action


The board temperature turns normal from low.

III. Recommended action


None

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

DEV/2/ BOARD TEMPERATURE LOWER: 1.3.6.1.4.1.2011.2.23.1.12.1.14


DEV/2/ BOARD TEMPERATURE LOWER: 1.3.6.1.4.1.2011.2.23.1.12.1.14 Certain This alarm message may appear only after the related alarm message is generated.

2.9.12 DEV/2/BOARD TEMPERATURE UPPER 1.3.6.1.4.1.2011.2.23.1.12.1.16


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: frameIndex is [INTEGER], slotIndex [INTEGER].[INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.16 hwBoaardTemperatureHigher This alarm message appears when the the board temperature is above the normal value. The board temperature is too high. Failure alarm Critical $1: OID $2: Frame No. $3: Frame No. $4: Slot No. Environmental alarm

II. Trigger action


The board temperature is too high.

III. Recommended action


Lower the temperature.

2-39

H3C S9500 Trap Message

Trap Messages

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

DEV/2/ BOARD TEMPERATURE NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.17


DEV/2/ BOARD TEMPERATURE UPPER 1.3.6.1.4.1.2011.2.23.1.12.1.16 Certain The related alarm is the recovery alarm.

2.9.13 DEV/2/BOARD TEMPERATURE NORMAL: 1.3.6.1.4.1.2011.2.23.1.12.1.17


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [OID]: frameIndex is [INTEGER], slotIndex [INTEGER].[INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.17 hwBoaardTemperatureFormHigherToNormal This alarm message appears when the the board temperature turns to the normal value. The board temperature turns normal from high. Recovery alarm Major $1: OID $2: Frame No. $3: Frame No. $4: Slot No. Environmental alarm

II. Trigger action


The board temperature turns normal from high.

III. Recommended action


None

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

DEV/2/ BOARD TEMPERATURE UPPER 1.3.6.1.4.1.2011.2.23.1.12.1.16


DEV/2/ BOARD TEMPERATURE UPPER 1.3.6.1.4.1.2011.2.23.1.12.1.16 Certain This alarm may appear only after the related alarm is generated.

2.9.14 DEV/2/BOARD REQUEST LOADING: 1.3.6.1.4.1.2011.2.23.1.12.1.18


I. Basic information
Item Alarm message Alarm OID Alarm name Description Description Trap [OID]: frameIndex is [INTEGER], slotIndex [INTEGER].[INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.18 hwRequestLoading This alarm message appears when the linecard requests to load software.

2-40

H3C S9500 Trap Message Item Meaning Alarm type Alarm level Alarm parameter Function type The board requests for loading. Event alarm Minor $1: OID $2: Frame No. $3: Frame No. $4: Slot No. Equipment alarm Description

Trap Messages

II. Trigger action


The board requests for loading.

III. Recommended action


None

IV. Related alarm message


None

2.9.15 DEV/2/LOAD FAILURE: 1.3.6.1.4.1.2011.2.23.1.12.1.19


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: frameIndex is [INTEGER], slotIndex [INTEGER].[INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.19 hwLoadFailure This alarm message appears when the linecard fails to load the software. The board fails to load the software. Failure alarm Major $1: OID $2: Frame No. $3: Slot No. Equipment alarm

II. Trigger action


The board fails to load the software.

III. Recommended action


Re-insert the board or change other boards.

IV. Related alarm message


None

2-41

H3C S9500 Trap Message

Trap Messages

2.9.16 DEV/2/LOAD FINISHED: 1.3.6.1.4.1.2011.2.23.1.12.1.20


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: frameIndex is [INTEGER], slotIndex [INTEGER].[INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.20 hwLoadFinished This alarm message appears when the board loads the software successfully. The boards successfully loads the software. Event alarm Minor $1: OID $2: Frame No. $3: Frame No. $4: Slot No. Equipment alarm

II. Trigger action


The board loads the software successfully.

III. Recommended action


None

IV. Related alarm message


None

2.9.17 DEV/2/POWER INSERT: 1.3.6.1.4.1.2011.2.23.1.12.1.23


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: power ID is [INTEGER] 1.3.6.1.4.1.2011.2.23.1.12.1.23 hwPowerInserted This alarm message appears when the power is inserted. Insert the power. Event alarm Major $1: OID $2: Power ID Equipment alarm

II. Trigger action


Insert the power.

III. Recommended action


None

2-42

H3C S9500 Trap Message

Trap Messages

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description

DEV/2/ POWER REMOVED: 1.3.6.1.4.1.2011.2.23.1.12.1.5


DEV/2/ POWER REMOVED: 1.3.6.1.4.1.2011.2.23.1.12.1.5 Certain This alarm message may appear only after the related alarm is generated.

2.9.18 DEV/2/PORT POE POWER ON: 1.3.6.1.2.1.105.0.1


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: slotIndex is [INTEGER], PortIndex [INTEGER].[INTEGER] 1.3.6.1.2.1.105.0.1 pethPsePortOnOffNotification The alarm appears when the PSE port is supplying power or does not supply power. The interval for two consecutive alarms is at least 500ms. This alarm indicates the status of the PSE port: open or closed. Event alarm Warning $1: Alarm OID $2: Slot No. $3: Slot No. $4: Interface No. Equipment alarm

II. Trigger action


The PSE port provides power for PD equipment.

III. Recommended action


If normal, no recovery is required.

IV. Related alarm message


None

2.9.19 DEV/2/PSE POWER USAGE OVER THRESHOLD: 1.3.6.1.2.1.105.0.1


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Description Trap [OID]: slotIndex is [INTEGER] Power is [INTEGER] Watts 1.3.6.1.2.1.105.0.2 pethMainPowerUsageOnNotification This alarm message appears when the current power of the PSE port exceeds the upper threshold. The interval for two consecutive alarms is at least 500ms. The current power of the PSE port exceeds the upper threshold.

2-43

H3C S9500 Trap Message Item Alarm type Alarm level Alarm parameter Function type Failure alarm Major $1: Alarm OID $2: Slot No. $3: Current PSE power Equipment alarm Description

Trap Messages

II. Trigger action


The current power of the PSE port exceeds the upper threshold.

III. Recommended action


Reduce the power of the PSE port.

IV. Related alarm message


None

2.9.20 DEV/2/PSE POWER USAGE BELOW THRESHOLD: 1.3.6.1.2.1.105.0.3


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description \r\n Trap [OID]: slotIndex is [INTEGER] Power is [INTEGER] Watts\r\n 1.3.6.1.2.1.105.0.3 pethMainPowerUsageOffNotification This alarm message appears when the current power of the PSE port is below the lower threshold. The interval for two consecutive alarms is at least 500ms. The current PSE power is below the lower threshold. Failure alarm Major $1: Alarm OID $2: Slot No. $3: Current PSE power Equipment alarm

II. Trigger action


The current PSE power is below the lower threshold.

III. Recommended action


Increase the power of the PSE device.

IV. Related alarm message


None

2-44

H3C S9500 Trap Message

Trap Messages

2.9.21 DEV/2/PD PULL: 1.3.6.1.4.1.2011.10.2.14.6.1


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap[OID]:slotIndex is [INTEGER], PortIndex is [INTEGER],Port status is [INTEGER] 1.3.6.1.4.1.2011.10.2.14.6.1 h3cpsePDChangeNotification This alarm message appears when the PD device is invalid or disconnected. The PD device is invalid or disconnected. Failure alarm Minor $1: Alarm OID $2: Slot No. $3: Port index $4: Port state Equipment alarm

II. Trigger action


The PD device is invalid or disconnected.

III. Recommended action


None

IV. Related alarm message


None

2.9.22 DEV/2/PD PULL: 1.3.6.1.4.1.2011.10.2.14.6.1


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap[OID]:slotIndex is [INTEGER], PortIndex is [INTEGER],Port status is [INTEGER] 1.3.6.1.4.1.2011.10.2.14.6.1 h3cpsePDChangeNotification The power supply status of the PD device changes (normal or forbidden). The power suppy status of the PD device changes. Event alarm Minor $1: Alarm OID $2: Slot No. $3: Port index $4: Port state Equipment alarm

II. Trigger action


The PD device normally provides power, or the power supply of the PD device is forbidden.

III. Recommended action


None

2-45

H3C S9500 Trap Message

Trap Messages

IV. Related alarm message


None

2.10 ENTITY
2.10.1 ENTITY/5/CONFIG CHANGE: 1.3.6.1.2.1.47.2.0.1
I. Basic information.
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: Configuration has been changed 1.3.6.1.2.1.47.2.0.1 entConfigChange This alarm message appears when the entity MIB configuration is changed. The entity MIB configuration is changed. Event alarm Minor $1: Alarm OID Communication alarm

II. Trigger action


1) This alarm will be sent when creating or deleting conception lines in the following MIB tables: entPhysicalTable entLogicalTable entLPMappingTable entAliasMappingTable entPhysicalContainsTable 2) The alarm will also be sent when modifying the following MIB objective instances: entPhysicalDescr entPhysicalVendorType entPhysicalContainedIn entPhysicalClass entPhysicalParentRelPos entPhysicalName entLogicalDescr entLogicalType entLogicalCommunity entLogicalTAddress entLogicalTDomain

2-46

H3C S9500 Trap Message

Trap Messages

entAliasMappingIdentifier

III. Recommended action


None

IV. Related alarm message


None

2.11 HWCM
2.11.1 HWCM/5/TRAP:1.3.6.1.4.1.2011.10.2.4.2.1
I. Basic information
Item Alarm message Alarm OID Alarm name Description Description configure changed: EventIndex=[integer], ommandSource=[integer], onfigSource=[integer], onfigDestination=[integer] 1.3.6.1.4.1.2011.10.2.4.2.1 h3cCfgManEventlog This alarm message appears when the current configuration is different from the saved. This alarm is detected every 10 minutes but is not sent repeatedly. Under the following situations, this alarm is generated to inform the user of a configuration change: SNMP SET operation; The initiation configuration file is changed; Enter into the system view; Check every 10 minutes whether the configuration is changed; Backup and recovery of CONFIGMAN MIB. Event alarm Warning h3cCfgLogSrcCmd: Configure the command source of the change event; h3cCfgLogSrcData: Configure the data source of the change event; h3cCfgLogDesData: Configure the datas destination of the change event. Equipment alarm

Meaning

Alarm type Alarm level Alarm parameter Function type

II. Trigger action


1) SNMP SET operation

This alarm message appears when the user uses SNMP to configure the equipment (SNMP SET operation). 2) Enter into the system view

This alarm is generated as a prompt for the user to configure the equipment when the user enters into the system view by typing the system-view command in the user view of the command line interface. 3) Check every 10 minutes whether the configuration is changed

The system checks every 10 minutes whether the configuration is changed. If so, the system sends this alarm message to inform the user. 4) Backup and recovery of CONFIGMAN MIB

2-47

H3C S9500 Trap Message

Trap Messages

When the user performs six types of operations in backup and recovery of CONFIGMAN MIB through NMS, the system generates this alarm message to inform the user.

III. Recommended action


This alarm is a warning and does not require alarm recovery.

IV. Related alarm message


None

2.11.2 HWCM/5/CFGCOPY: 1.3.6.1.4.1.2011.10.2.4.2.2


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description configuration copy: 1.3.6.1.4.1.2011.10.2.4.2.2 h3cCfgOperateCompletion This alarm message appears when h3cCfgOperateTable is successfully created. When the user performs six types of operations in backup and recovery of CONFIGMAN MIB through NMS, if the notice for complete operation is enabled, the system generates this alarm to note the user. Event alarm Warning h3cCfgOperateType: Operation type; h3cCfgOperateTime: Opeation start event; h3cCfgOperateState: Operation state (successful or not); h3cCfgOperateEndTime: Operation end time; Equipment alarm

II. Trigger action


When the user performs the six types of operations in backup and recovery of CONFIGMAN MIB through NMS: running2startup, startup2running, net2startup, startup2net, running2net, and net2running, this alarm message is generated to note the user of the operation result.

III. Recommended action


Pay special attention to the value of parameter h3cCfgOperateState (operation state) in the alarm message for the operation result. If the value of this parameter is not opSucess(2), consider the cause of the failed operation or re-execute the operation.

IV. Related alarm message


None

2-48

H3C S9500 Trap Message

Trap Messages

2.12 L2INF
2.12.1 L2INF/2/ PORT LINK STATUS CHANGE: 1.3.6.1.6.3.1.1.5.4
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: portIndex is [INTEGER], ifAdminStatus is [INTEGER], ifOperStatus is [INTEGER] 1.3.6.1.6.3.1.1.5.4 linkUp This alarm message appears when the port state turns UP. The port state turns UP. Event alarm Minor $1: Alarm OID $2: Port index $3: Switch state of actual interface operation $4: Current state of the interface Equipment alarm

II. Trigger action


The port state turns UP.

III. Recommended action


None

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description L2INF/2/ PORT LINK STATUS CHANGE: 1.3.6.1.6.3.1.1.5.3 L2INF/2/ PORT LINK STATUS CHANGE: 1.3.6.1.6.3.1.1.5.4 Prossible The port state changes (from UP to DOWN or from DOWN to UP).

2.12.2 L2INF/2/PORT LINK STATUS CHANGE: 1.3.6.1.6.3.1.1.5.3


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Description Trap [OID]: portIndex is [INTEGER], ifAdminStatus is [INTEGER], ifOperStatus is [INTEGER] 1.3.6.1.6.3.1.1.5.3 linkDown This alarm message appears when the port state turns DOWN. The port state turns DOWN. Event alarm Minor $1: Alarm OID $2: Port index $3: Switch state of actual interface operation $4: Current state of the interface

2-49

H3C S9500 Trap Message Item Function type Equipment alarm Description

Trap Messages

II. Trigger action


The port state turns DOWN.

III. Recommended action


None

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause Description L2INF/2/ PORT LINK STATUS CHANGE: 1.3.6.1.6.3.1.1.5.4 L2INF/2/ PORT LINK STATUS CHANGE: 1.3.6.1.6.3.1.1.5.3 Prossible The port state changes (from UP to DOWN or from DOWN to UP).

2.13 MIX
2.13.1 MIX/2/SLAVE SWITCH OVER: 1.3.6.1.4.1.2011.2.23.1.17.10.1
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description Trap [OID]: Slave switch over. 1.3.6.1.4.1.2011.2.23.1.17.10.1 hwSlaveSwitchOver This alarm message appears in switchover between master and slave boards. The switchover between master and slave boards is complete. Recovery alarm Major $1: Alarm OID Equipment alarm

II. Trigger action


The master and slave boards are switched over.

III. Recommended action


This alarm is automatically recovered.

IV. Related alarm message


None

2-50

H3C S9500 Trap Message

Trap Messages

2.14 RMON
2.14.1 rmon/2/ ALARMUP: 1.3.6.1.2.1.16.0.1
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Description Trap [OID] Alarm table [INTEGER] monitors [OID] with sample type [INTEGER],has sampled alarm value [LONG] uprise [INTEGER]. 1.3.6.1.2.1.16.0.1 risingAlarm This alarm message appears when the monitored value equals or exceeds the upper threshold. The monitored value equals or exceeds the upper threshold. Event alarm Minor $1: Alarm OID $2: Row index $3: Alarm variable $4: Sample type $5: Sample value $6: Upper threshold Service quality alarm

Alarm parameter

Function type

II. Trigger action


This alarm is generated when the state of the alarm group is valid, and the sample value of the alarm variable (prialarmVariable) equals or exceeds the upper threshold (prialarmRisingThreshold).

III. Recommended action


Delete the rows corresponding to the row index, or increase the upper threshold, or change the states of the rows corresponding to the row index to underCreation.

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause fallingAlarm None Certain These two alarm messages are sent in turns. Description

2.14.2 rmon/2/ ALARMFALL: 1.3.6.1.2.1.16.0.2


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Description Trap [OID] Alarm table [INTEGER] monitors [OID] with sample type [INTEGER], has sampled alarm value [LONG] less than (or =) [INTEGER]. 1.3.6.1.2.1.16.0.2 fallingAlarm This alarm message appears when the monitored value is equal to or below the lower threshold. The monitored value is equal to or below the lower threshold. 2-51

H3C S9500 Trap Message Item Alarm type Alarm level Event alarm Minor $1: Alarm OID $2: Row index $3: Alarm variable $4: Sample type $5: Sample value $6: Lower threshold Service quality alarm Description

Trap Messages

Alarm parameter

Function type

II. Trigger action


This alarm is generated when the state of the alarm group is valid, and the sample value of the alarm variable (prialarmVariable) is equal to or below the lower threshold (prialarmRisingThreshold).

III. Recommended action


Delete the rows corresponding to the row index, or reduce the lower threshold, or change the states of the rows corresponding to the row index to underCreation.

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause risingAlarm None Certain These two alarm messages are sent in turns. Description

2.14.3 rmon/2/ RISING: 1.3.6.1.4.1.2011.1.3.4.0.1


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Description Trap [OID] Private alarm table [INTEGER] monitors [OCTET] with sample type [INTEGER],has sampled alarm value [INTEGER] uprise [INTEGER]. 1.3.6.1.4.1.2011.1.3.4.0.1 pririsingAlarm This alarm message appears when the alarm variable equals or exceeds the upper threshold. The monitored value equals or exceeds the upper threshold. Event alarm Minor $1: Alarm OID $2: Row index $3: Alarm variable $4: Sample type $5: Sample value $6: Upper threshold Service quality alarm

Alarm parameter

Function type

2-52

H3C S9500 Trap Message

Trap Messages

II. Trigger action


This alarm is generated when the state of the extended alarm group is valid, and the sample value of the alarm variable (prialarmVariable) equals or exceeds the upper threshold (prialarmRisingThreshold).

III. Recommended action


Delete the rows corresponding to the row index, or increase the upper threshold, or change the states of the rows corresponding to the row index to underCreation.

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause prifallingAlarm None Certain These two alarm messages are sent in turns. Description

2.14.4 rmon/2/FALLING: 1.3.6.1.4.1.2011.1.3.4.0.2


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Description Trap [OID] Private alarm table [INTEGER] monitors [OCTET] with sample type [INTEGER],has sampled alarm value [INTEGER] less than(or =) [INTEGER]. 1.3.6.1.4.1.2011.1.3.4.0.2 prifallingAlarm This alarm message appears when the alarm variable is equal to or below the lower threshold. The monitored value is equal to or below the lower threshold. Event alarm Minor $1: Alarm OID $2: Row index $3: Alarm variable $4: Sample type $5: Sample value $6: Lower threshold Service quality alarm

Alarm parameter

Function type

II. Trigger action


This alarm is generated when the state of the extended alarm group is valid, and the sample value of the alarm variable (prialarmVariable) is equal to or below the lower threshold (prialarmRisingThreshold).

III. Recommended action


Delete the rows corresponding to the row index, or reduce the lower threshold, or change the states of the rows corresponding to the row index to underCreation.

2-53

H3C S9500 Trap Message

Trap Messages

IV. Related alarm message


Item Related alarm message Relationship Relation degree Cause pririsingAlarm None Certain These two alarm messages are sent in turns. Description

2.15 VFS
2.15.1 VFS/5/TRAP: 1.3.6.1.4.1.2011.10.2.5.1.3.1
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description [oid] Copy operation completed CopyIndex=[integer], CopyStatus =[integer] 1.3.6.1.4.1.2011.10.2.5.1.3.1 h3cFlhOperNotification When creating a row in the h3cFlhOpTable table, if the value of h3cFlhOperEndNotifications is set to true, this alarm message appears with the result of the operation. This alarm message displays the execution result of the flash operation. Event alarm Major $1: Alarm OID $2: Current row index $3: Operation result Service quality alarm

II. Trigger action


When creating a row in the h3cFlhOpTable table, if the value of

h3cFlhOperEndNotifications is set to true, this alarm is generated after the new row is successfully set up. The alarm displays the execution result of the operation designated by h3cFlhOperType.

III. Recommended action


The user can judge whether the returned result is operation failed based on the returned operation code.

IV. Related alarm message


None

2-54

H3C S9500 Trap Message

Trap Messages

2.16 SNMP-V2
2.16.1 ColdStart: 1.3.6.1.6.3.1.1.5.1
I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description None 1.3.6.1.6.3.1.1.5.1 ColdStart A coldStart trap signifies that the SNMPv2 entity, acting in an agent role, is reinitializing itself and that its configuration may have been altered. The SNMP agent module in the equipment is re-initialized and its configuration may have changed. Event alarm Warning None Communication alarm

II. Trigger action


In the process of equipment startup, the initialization of the SNMP agent module is complete.

III. Recommended action


None

IV. Related alarm message


None

2.16.2 WarmStart: 1.3.6.1.6.3.1.1.5.2


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description None 1.3.6.1.6.3.1.1.5.2 WarmStart A warmStart trap signifies that the SNMPv2 entity, acting in an agent role, is reinitializing itself such that its configuration is unaltered. The SNMP agent module in the equipment is re-initialized and its configuration is not changed. Event alarm Warning None Communication alarm

II. Trigger action


In the running process of the equipment, use snmp-agent in the command line to enable the SNMP agent.

2-55

H3C S9500 Trap Message

Trap Messages

III. Recommended action


None

IV. Related alarm message


None

2.16.3 AuthenticationFailure: 1.3.6.1.6.3.1.1.5.5


I. Basic information
Item Alarm message Alarm OID Alarm name Description Meaning Alarm type Alarm level Alarm parameter Function type Description None 1.3.6.1.6.3.1.1.5.5 AuthenticationFailure An authenticationFailure trap signifies that the SNMPv2 entity, acting in an agent role, has received a protocol message that is not properly authenticated. While all implementations of the SNMPv2 must be capable of generating this trap, the snmpEnableAuthenTraps object indicates whether this trap will be generated. The received protocol message is not properly authenticated. Failure alarm Major None Communication alarm

II. Trigger action


This alarm has the following trigger actions: For SNMPv1/v2c, the community used in the message does not exist; For SNMPv3, the authentication cipher key used for sending the message is wrong.

III. Recommended action


Based on the cause, the recommended actions include: For SNMPv1/v2c, use the correct community connection equipment; For SNMPv3, use the correct authentication cipher key.

IV. Related alarm message


None