Thank you for purchasing a Forza 500/750/1000VA Series UPS system product. To enjoy all the features and benefits of this unit, please read and follow all the instructions of installation and operation completely.
Front panel
1. Power Switch 2. LED Indicators - AC Mode: Green Lighting Battery Mode : Green Flashing 3. AC Mode - Load Level LEDs Backup Mode Battery Capacity LEDs 4. Fault LED
CAUTION!
CAUTIONS ABOUT UPS UNIT
. The utilized voltage of this UPS may be hazardous. The unit contains no user serviceable parts and do not attempt to disassemble the unit. Only the factory service technician can maintain the unit. . Connection to any other type of receptacle other than a two-pole, three-wire grounding receptacle may result in electrical shock. . In case of any emergencies, turn the power switch to the off position and disconnect the power cord from the AC power supply. . Do not plug the UPS AC input power cord into its own output. . Do not connect the power strip or surge suppressor to the UPS. . Do not connect the appliances which is not related to computer peripherals, such as medical equipments, life-support equipments, microwave ovens, or vacuum cleaners to the UPS . Unplug the UPS before cleaning the unit and do not use liquid or spray detergent.
Forza 1000
Utility Line mode The 5th green LED lighting The 1st to 4th green LED lighting to indicate load level LED1 (green) : >75% load level.LED2 (green) : >50% load level. LED3 (green) : >25% load level.LED4 (green) : >00% load level. Battery mode The 5th green LED blinking The 1st to 4th green LED lighting to indicate battery capacity LED1 (green) : battery voltage > 25V LED2 (green) : battery voltage > 23V LED3 (green) : battery voltage > 22VLED4 (green) : battery voltage > 21V Fault Red LED Lighting Battery Replacement Red LED Lighting
. The UPS contains an internal battery which is 12Vdc, sealed, lead-acid, 6 cells battery. . Do not dispose the batteries into fire. The batteries are explosive under the high temperature. . Do not try to open the batteries. The battery contains toxic electrolyte which is harmful to the skin and eyes. . A battery can cause the risk of electrical shock and high short circuit current. The following precautions should be taken: 1) Remove watches, rings, or other metal objects from the hand. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots. 4) Do not lay tools or metal parts on the top of batteries. . Disconnect charging source prior to connecting or disconnecting batteries terminal. Service of batteries should be performed or supervised by people who have knowledge about batteries and the required precautions. . When replacing batteries, replace with the same number of the sealed lead-acid batteries.
. Avoid any kind of liquid or any other objects getting into the UPS unit. Do not place beverages or any other vessels which contains any kind of liquid nearby the unit. . This unit should be installed and operated in the environment under certain required conditions: (range of temperature, indoor, without conductive contaminants). Do not install the UPS at the locations nearby running water or excessively humid. . To reduce the risk of overheating, do not cover the cooling vents. Avoid exposing the unit to the direct sunlight or installing the unit nearby the heat emitting appliances such as electrical heaters or furnaces. . The socket outlet utility shall be installed nearby the UPS and also can be accessed very easily.
8
SL-502C/502a/752C/752a SL-501/502U/501D SL-751/752U/751D
System Introduction
Forza 500/750/1000VA is designed for power protection for your personal computer and its peripherals. The compact size is specially designed for limited office and home working space. It may be small, but can provide you the maximized power protection while encountering a power failure.
Features
. Boost and Buck AVR for stabilizing input power voltage . Built-in DC start function for starting up itself without AC input power . Smart USB Communication Port for transmitting UPS real-time conditions and remote control . Microprocessor Control Design guarantees the high reliability . Auto Self-Charge when UPS is in off status . Auto Self- Restart when AC input power is recovered . Modem/Phone Line Surge Protection . The highest standard of power protection : Discharge, Overcharge, and Overload Protection . WinPower, a free software available online for UPS real-time monitoring and controlling
SL-1001/1001D/1001UL /1002U
SL-1002C/1002a
Back Panel
1. Output Receptacles 2. AC Input 3. Modem/Phone Line Surge Protection 4. Circuit Breaker / Fuse 5. USB Port 6. Cooling Fan 7. Surge Protection 8. AC Input with AC Fuse
Install the UPS unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high. On the other hand, place the UPS unit away from monitor at least 20cm to avoid interference.
When power fails, the backup time is shortened than the normal status
Possible Cause The UPS is overload Low battery voltage Battery defect due to high temperature operation environment, or improper battery operation Solution Remove some non-critical load Charge battery 8 hours or more Replace the battery with the same type
This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for 8 hours.
4. Connect to Computer
Connect one computer-related device into each of the power receptacles supplied on the back of the UPS.
Plug incoming internet line into the In socket at the back of the UPS. Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS. Plug the other end to the modem input socket.
To start up the UPS, press the power switch button. (When switching on, the LED will light up). To turn off, press the button again.
Specifications
Installation procedure:
1. Go to the website: http://www.forzaups.com/download.htm. 2. Choose the type of operation system and follow the instructions on the website to download the software. 3. When downloading all required files from the internet, enter the serial No: 511C1-012200100-478DF2A to install the software.
4. When your computer restarts, the WinPower software will appear as a green plug icon located in the system tray, near the clock. 5. To access the Forza WinPower software as an administrator, you must enter the password Administrator ( Please note that the A must be capitalized )
MODEL
CAPACITY INPUT VA/W Voltage
400
500
600
700
400VA/240W 500VA/300W 600VA/360W 700VA/420W 110/120VAC or 220/230/240VAC 81-140VAC or 162-290VAC 45-65 Hz (Auto Sensing) 110/120/220/230/240VAC +/-10% 50Hz or 60Hz +/-1 Hz Modified Sinewave 6V4Ahx2 or 12V4.5Ahx1 8 minutes 12V7Ah x 1 22 minutes
OUTPUT
BATTERY
8 hours to 90% after complete discharge 2-6 ms Green lighting Green flashing Sounding every 10 seconds Sounding every second Sounding every 0.5 second Sounding every 2 seconds Continuously sounding Discharge, overcharge, and overload protection 330X100X140 5kgs 6kgs
TRANSFER TIME Typical INDICATOR AC Mode Backup Mode Backup Mode Low Battery AUDIBLE ALARM Overload Battery Replacement Fault PROTECTION PHYSICAL WEIGHT ENVIRONMENT Full Protection Dimension (mm), DXWXH Net Weight Operating Environment Noise Level INTERFACE Smart RS-232 USB Port (Option)
0- 40C, 0-90 % relative humidity (non-condensing) Less than 40dB Windows family, Sun Solaris, IBM Aix, Compaq True64, UnixWare, FreeBSD, HP-UX, Linux and MAC Windows 98/2000/ME/XP