5/12RES
Multi-Fuel
LP Vapor/Natural Gas
Standard Features
D Powerful
d The Kohler 12 kW generator is powerful enough to
start and run a typical 4 ton (48,000 BTU) central
air conditioner, as well as other home appliances
and electronics *
D Designed for easy installation
d Polymer base eliminates the need for a concrete
mounting pad, reducing installation time and cost
d Fuel and electrical connections through the
enclosure wall eliminate the need for stub-ups
through the bottom
D Quiet
d Quiet operation: 65 dB(A) at 7 m, similar to a
typical vacuum cleaner
d Sound enclosure maintains neighborhood solitude
d Internal exhaust system with a USDA Forest
Service-approved spark arrestor
D ADC 2100 Advanced Digital Control is designed for
D UL 2200 listed (60 Hz models)
today’s most sophisticated electronics
D UL listed to Canadian safety standards
d Digital electronic isochronous governor
(60 Hz models)
d Digital voltage regulator
D Emission Certifications (60 Hz models):
d LED display provides diagnostic capability
d California Air Resources Board (CARB)-certified
D Engine features for both LP vapor and natural gas (field-
d Digital Spark Advance Module (DSAM) optimizes convertible)
engine performance for natural gas and LP vapor d Meets Environmental Protection Agency (EPA)
fuels (12RES only) nonstationary unit requirements
d Simple field-conversion between natural gas and
D Kohler Co. provides one-source responsibility for the
LP vapor fuels while maintaining emission
generating system and accessories
certification
D Generator set and components are prototype-tested,
D AC-powered 6-amp battery charger
factory-built, and production-tested
D Integral vibration isolation
D Premium five-year limited warranty included
D Rodent-proof construction
Generator Ratings
Standby Amps Standby Ratings, kW/kVA
Model Generator
Series Voltage Phase Hz Model Natural Gas LP Gas Natural Gas LP Gas
8.5RES 120/240 1 60 2F4 29 35 7.0/7.0 8.5/8.5
8.5RES 115/230 1 50 2F4 27 33 6.3/6.3 7.5/7.5
12RES 120/240 1 60 2F4 43 50 10.4/10.4 12.0/12.0
12RES 115/230 1 50 2F4 40 46 9.3/9.3 10.5/10.5
RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loads with an average
load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO--3046/1, BS5514, AS2789, and DIN 6271. GENERAL
GUIDELINES FOR DERATING: ALTITUDE: Derate 4% per 305 m (1000 ft.) elevation above 153 m (500 ft.). TEMPERATURE: Derate 1.5% per 5.5_C (10_F) temperature increase above 16_C
(60_F). Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your
local Kohler Co. generator distributor for availability.
* Due to the cycling operation of many electrical appliances, the generator set may not run all appliances simultaneously. Check the appliance manufacturer’s specifications for actual power
requirements. Consult a Kohlerr Power Systems professional for your exact residential power system requirements.
- __________________________________________ NOTE: This drawing is provided for reference only and should not be used for planning
installation. Contact your local distributor for more detailed information.
- __________________________________________
- __________________________________________ DISTRIBUTED BY:
- __________________________________________
- __________________________________________
- __________________________________________
- __________________________________________
- __________________________________________