32773 KW
> > > > > > > > > >
Compressori a vite (Omicron V Evo) - Compressori scroll (Omicron S Evo) Refrigerante R134a Estesi limiti di funzionamento Kit idronico sempre possibile All in One Screw Compressors (Omicorn V Evo) - Scroll Compressors (Omicron S Evo) R134a Refrigerant Wider function limits Hidronic Kit always available All in One
Per darvi sempre la soluzione ideale, qualora vogliate assicurare tutto lanno, indipendentemente dalla temperatura dellaria esterna, acqua calda ed acqua refrigerata agli utilizzi, Blue Box Group ha sviluppato Omicron S Evo ed Omicron V Evo: chiller e caldaia elettrica, all in one. Due gamme di polivalenti che intendono ricoprire ogni richiesta, dal residenziale al terziario senza soluzione di continuit. Niente pi caldaia, impianto semplificato, risparmio energetico... La soluzione ideale, tutta per voi. To give you an ideal solution, whenever you want to ensure hot and cooled water all year round to the utilities, independently from the temperature of the external air, Blue Box Group has developed Omicron S Evo and Omicron V Evo: an all in one chiller and electric boiler. Two ranges of multifunctional units that intend to cover every request, from residential to the tertiary with seamless coverage. No more boiler, simplified system, energy saving... The ideal solution, just for you.
1
A PERSONALISED RANGE
A wide product mix pf powers and configurations that respond to the different installation requests: Omicron is available in 34 sizes (16 for Omicron S Evo and 18 for Omicron V Evo) form 31 to 773 Kw. Those specifics aim to cover a wide range of application: industrial, hotels, home. PLUS An extraordinary moltiplicity of available versions meet every requests: HT Version for hot water up to 65 C LT Version for Low Temperature for low temperature down to -10 C LN and SLN Versions mean a Low Noise unit and Super Low Noise unit Kit Hydronic available Perfect also for 2 pipes than 4 pipes
v
5
tempo time
Surriscaldamento Superheating
EFFICIENZA AL TOP
Risparmio energetico, precisione e comfort assicurati, con la valvola termostatica elettronica e la regolazione precisa della potenza erogata rigorosamente di serie. I PLUS Qualit di regolazione del flusso refrigerante. Velocit nel raggiungimento della stabilit della macchina. Variabilit del carico termico seguita con assoluta precisione. Esteso campo di lavoro con conseguente ampliamento dei limiti di funzionamento dellunit. Riduzione dei costi di esercizio.
TOP EFFICIENCY
The electronic thermostatic valve and the precise adjustment of power, distributed rigorously as standard, allow for energy saving, precision and guaranteed comfort. ADVANTAGES Ability to adjust refrigerant flow. Quickly attained machine stability. Variability of the heat load with absolute precision. Large working field with consequent increase of the units functioning limits. Reduction of working costs.
11
MAXIMUM SILENCE
Confirming the extreme versatility of the Blue Box offer, the three sound levels available for all sizes are highlighted: PLUS There are two variants available as well as the standard, in order to guarantee the lowest sound emission levels: Standard Version: thanks to its excellent design, excellent sound levels are obtained Silenced Version: for anyone wanting a lower noise level, the LN version has a compressor compartment that is completely insulated acoustically using sound-absorbent and sound-proofing material. Super Silenced Version: for the most demanding regarding noise performance, we offer the SLN version: as well as the set-ups of the LN version, we envision batteries with increased surfaces and reduction of the fan speed.
12
13
INNOVAZIONE BREVETTATA
Un sistema di sbrinamento innovativo brevettato (N. 1335232) da Blue Box consente di attivare la procedura di inversione del ciclo, ottimizzandone la durata. I PLUS Rispetto ai tradizionali sistemi, riduzione del 10% dellassorbimento elettrico durante il funzionamento in pompa di calore. Incremento dellenergia utile trasferita al sistema nellintervallo tra gli sbrinamenti.
PATENTED INNOVATION
A patented innovative defrosting system (N.1335232) by Blue Box, which allows the activation of a cycle reversal procedure, thus optimising the duration. ADVANTAGES Reduction of electrical absorption by 10% during functioning of the heat pump with respect to traditional systems. Increase of useful energy transferred to the system in the interval between defrosting.
15
16
17
SOLUZIONE IMPIANTISTICA 2 TUBI COMPRESSORI SCROLL, 4 CIRCUITI. PICCOLO ALBERGO (592 m2 da riscaldare, ripartiti su 3 piani) sito in una citt caratterizzata dal clima continentale tipicamente europeo. 15 camere e 33 posti letto FABBISOGNO ACS (condizioni di progetto) 59 [MWh/anno] FABBISOGNO RISCALDAMENTO (condizioni di progetto) 160 [MWh/anno] FABBISOGNO TOTALE ricoperto interamente dallunit polivalente o dalla caldaia Il profilo del carico termico dellunit Omicron S nei mesi estivi si annulla, differenziandosi da quello della caldaia perch si prevede sia necessario il condizionamento dei locali. Qualora sia richiesta acqua calda sanitaria durante il raffrescamento estivo interviene il recupero totale e lenergia fornita gratuita, o, in altre parole, non si ha un consumo aggiuntivo di energia.
SOLUTION 2 PIPES SCROLL COMPRESSORS, 4 CIRCUITS. SMALL HOTEL (3 floors on 592 sqm total): 15 rooms, 33 beds in a continental city with an european tipical climate. ACS NEEDS (project conditions) 59 [MWh/year] HEATING NEEDS (project conditions) 160 [MWh/year] TOTAL NEEDS managed by the boiler or by the boiler In the summer time the heating load is pointless because is expected to use chiller units Omicron S to condition the environments. On the other hand, if a new request of hot domestic water during the summer the total recovery works and the energy provided is for free. this means no more extra energy consumptions.
18
$
19
v
SOLUZIONE IMPIANTISTICA 4 TUBI COMPRESSORI VITE, 2 CIRCUITI. TORRE DUFFICI (3960 m2 da riscaldare, ripartiti su 3 piani) sito in una citt europea caratterizzata dal clima mite. Dotato di mensa, sala conference e 5 sale riunioni. 480 dipendenti FABBISOGNO ACS (condizioni di progetto) 71 [MWh/anno] FABBISOGNO RISCALDAMENTO (condizioni di progetto) 1095 [MWh/anno] FABBISOGNO TOTALE ricoperto interamente dallunit polivalente o dalla caldaia si tiene conto anche del carico frigorifero estivo in quanto in marzo, aprile, ottobre, novembre richiesto un contemporaneo raffrescamento e riscaldamento dei locali IL RISPARMIO ENERGETICO CHE SI OTTIENE CON OMICRON V EVO FRUTTO DI: 1) unalta efficienza ai carichi parziali che permette di parzializzare con continuit da quasi il 25% del carico termico richiesto. 2) la possibilit di sfruttare la contemporanea richiesta di caldo e freddo dei diversi locali che implica un funzionamento in recupero totale per 4 mesi allanno, ottenendo energia termica gratuita. in questa simulazione si data priorit alla richiesta di freddo.
SOLUTION 4 PIPES SCREW COMPRESSORS, 2 CIRCUITS. GLASS TOWER (for commercial use): 3960 sqm to heat on a 3 floors building, in a tipical european temperate town. the building has a mess, conference room and 5 meeting rooms for 480 employees. ACS NEEDS (project conditions) 71 [MWh/year] HEATING NEEDS (project conditions) 1095 [MWh/year] TOTAL NEEDS managed by the boiler or by the multifuncional unit concerning the contemporary chilling and heating of the environments in many months (march, april, october, november) we have THE ENERGY SAVING WITH OMICRON V EVO IS DUE TO: 1) an excellent efficiency on the partial loads allows a costant partiallization for 25% of the heating load requested 2) the possibility to exploit the contemporary request of heat and chill for different environment that means a total recovery for 4 months per year. this means heating energy for free. the solution we show below was studied by prioriting the request of chill
20
21
efficienza efficiency
potenza outp
22
Accessori Accessories
23
3.2 kW kW kW l/h kPa kW kW kW l/h kPa kW kW kW 32 10 11 2,80 5460 27 34 10 11 3,07 5904 26 33 10 42 3,31 4,31 l/h kPa l/h kPa n/n % n m3/s 5589 28 7278 40 2/1 50-100 2 5,9
4.2 42 13 15 2,84 7255 28 47 13 14 3,31 8096 28 43 13 56 3,33 4,33 7383 29 9599 39 2/1 50-100 2 5,53
5.2 52 18 20 2,63 8898 24 56 16 18 3,14 9661 26 55 17 72 3,24 4,24 9408 27 12311 42 2/1 50-100 2 5,53
6.2 62 21 23 2,63 10607 26 67 19 22 3,08 11465 26 64 20 84 3,18 4,18 10994 28 14454 41 2/1 50-100 3 9,06
7.2 72 24 26 2,73 12334 27 80 23 25 3,23 13756 28 73 23 97 3,14 4,14 12595 28 16605 41 2/1 50-100 3 8,64
24
La presente scheda riporta i dati caratteristici delle versioni base e standard della serie; per i dettagli si faccia riferimento alla specifica documentazione.
8.2 87 31 33 2,60 14992 26 101 28 30 3,36 17396 27 89 30 119 2,97 3,97 15333 27 20492 37 2/1 50-100 3 8,28
9.2 96 35 38 2,54 16499 24 110 30 33 3,35 18870 27 100 33 133 3,05 4,05 17238 26 22898 40 2/1 50-100 3 8,28
11.2 113 36 42 2,70 19374 26 124 33 39 3,16 21281 28 114 35 149 3,24 4,24 19560 27 25589 40 2/1 50-100 3 17,39
10.4 96 29 35 2,74 16586 28 106 29 35 3,07 18244 27 98 29 128 3,37 4,37 16915 29 21929 39 4/2 25-50-75-100 3 17,39
11.4 107 35 41 2,61 18342 26 120 33 39 3,07 20583 27 107 35 141 3,06 4,06 18335 26 24332 38 4/2 25-50-75-100 3 17,39
12.4 128 41 47 2,74 22083 27 139 39 45 3,08 23833 26 130 40 170 3,25 4,25 22322 28 29200 39 4/2 25-50-75-100 3 16,33
14.4 144 49 55 2,61 24734 25 159 45 51 3,11 27295 25 149 46 195 3,21 4,21 25568 27 33543 38 4/2 25-50-75-100 3 16,33
16.4 160 54 62 2,57 27489 26 178 50 58 3,05 30561 26 162 53 215 3,03 4,03 27785 27 36946 38 4/2 25-50-75-100 4 23,31
17.4 174 62 70 2,47 29957 26 191 55 63 3,02 32889 25 179 59 239 3,02 4,02 30856 28 41059 39 4/2 25-50-75-100 4 23,31
19.4 197 68 76 2,60 33950 21 220 61 69 3,19 37887 27 202 65 267 3,09 4,09 34726 22 45948 40 4/2 25-50-75-100 4 21,92
21.4 217 76 84 2,59 37291 20 236 66 74 3,18 40559 28 226 71 296 3,20 4,20 38846 22 50970 44 4/2 25-50-75-100 4 21,92
Ambient air temperature 35C; evaporator inlet/outlet water temperature 12-7 C. Total power input is sum of compressors and funs power input. Ambient air temperature 7C DB, 6C WB; condenser inlet/outlet water temperature 40-45 C. Sound power values calculate in compliance with ISO 3744. Sound pressure values measured at 10 meters from the unit in free field conditions and directional factor Q=2.
This datasheet gives the characteristic data of the basic and standard versions of the series; for details refer to the specific documentation.
25
23.1 kW kW kW l/h kPa kW kW kW l/h kPa kW kW kW 231 73 80 2,88 39725 25 245 65 72 3,41 41840 28 238 70 308 3,43 4,43 l/h kPa l/h kPa n/n % n m3/s 41005 27 52567 43 1/1 3 4 24,2
25.1 252 85 92 2,73 43336 29 269 72,5 79,5 3,38 45905 34 267 78 345 3,44 4,44 45898 33 58805 52 1/1 3 4 24,22
28.1 280 93 100 2,81 48151 33 302 80,2 87,2 3,46 51535 39 294 86 380 3,44 4,44 50644 37 64880 58 1/1 3 4 23,89
31.1 301 102 109 2,76 51763 36 323 85,9 92,9 3,48 55097 43 322 92 414 3,49 4,49 55339 41 70648 67 1/1 3 4 23,89
33.2 335 105 116 2,90 57610 35 364 92,2 102,7 3,54 62086 43 345 100 445 3,44 4,44 59352 37 75995 61 2/2 6 6 37,22
35.2 349 115 126 2,78 60017 39 376 101 111,5 3,37 64186 46 363 108 470 3,38 4,38 62411 42 80276 68 2/2 6 6 37,22
213 25 193 25 93 61 87 55
193 25 159 25 94 62 87 55
170 25 143 25 94 62 87 55
151 25 198 25 94 62 88 56
185 25 195 25 94 62 89 57
170 25 179 25 94 62 89 57
Temperatura aria esterna 35C; temperatura acqua ingresso-uscita evaporatore 12-7C Temperatura aria esterna 7C BS, 87% UR; temperatura acqua ingresso-uscita condensatore 40-45 C Temperatura acqua ingresso-uscita evaporatore 12-7C; temperatura acqua ingresso-uscita recuperatore 40-45 C Valori di potenza sonora in campo libero calcolati secondo la normativa ISO 3744; condizioni di lavoro nominali. Livelli di pressione sonora riferiti a 10 metri dallunit in campo libero alle condizioni di lavoro nominali, secondo ISO 3744.
26
La presente scheda riporta i dati caratteristici delle versioni base e standard della serie; per i dettagli si faccia riferimento alla specifica documentazione.
v
37.2 370 126 137 2,71 63629 33 400 107 117,5 3,40 68184 40 392 115 507 3,42 4,42 67420 37 86442 60 2/2 6 6 37,22 40.2 399 138 149 2,68 68616 37 426 114,5 125 3,40 72622 43 428 123 551 3,48 4,48 73530 42 93955 68 2/2 6 6 37,22 43.2 437 140 154 2,83 75150 39 457 119,5 133,5 3,43 78054 44 449 131 580 3,42 4,42 77230 41 99043 67 2/2 6 8 48,33 47.2 464 162 176 2,63 79794 44 491 134,5 148,5 3,31 83825 50 489 147 635 3,33 4,33 84037 49 108409 79 2/2 6 8 48,33 51.2 491 174 188 2,62 84437 27 515 143 157 3,28 87805 31 525 155 679 3,40 4,40 90280 50 115951 50 2/2 6 8 48,33 54.2 541 191 205 2,64 93035 40 617 161,5 175,5 3,52 105290 53 579 171 750 3,38 4,38 99535 31 127952 75 2/2 6 8 45,56 58.2 581 213 227 2,56 99914 27 656 173 187 3,51 111927 34 634 184 818 3,45 4,45 109099 32 139661 51 2/2 6 8 45,56 61.2 635 194 212 3,00 109200 35 681 172,5 190 3,59 116282 42 649 181 829 3,59 4,59 111533 42 141530 59 2/2 6 10 56,89 67.2 665 209 227 2,93 114359 37 712 180 197,5 3,60 121446 44 675 189 864 3,57 4,57 116058 28 147419 62 2/2 6 10 56,89 70.2 696 229 247 2,82 119690 41 762 194,5 212 3,60 130117 50 720 202 922 3,56 4,56 123785 37 157306 70 2/2 6 10 56,89 73.2 727 242 259 2,81 125021 37 778 198,5 216 3,60 132823 43 761 208 969 3,66 4,66 130876 41 165366 64 2/2 6 10 56,89 80.2 773 260 278 2,79 132932 42 865 217,5 235 3,68 147658 53 811 224 1035 3,63 4,63 139527 41 176595 73 2/2 6 10 54,44
1) 2) 3) 4) 5)
Ambient air temperature 35C; evaporator inlet/outlet water temperature 12-7 C. Total power input is sum of compressors and funs power input. Ambient air temperature 7C DB, 6C WB; condenser inlet/outlet water temperature 40-45 C. Sound power values calculate in compliance with ISO 3744. Sound pressure values measured at 10 meters from the unit in free field conditions and directional factor Q=2.
This datasheet gives the characteristic data of the basic and standard versions of the series; for details refer to the specific documentation.
27
Blue Box Group S.r.l. I - 30010 Cantarana di Cona (VE) - Via Valletta, 5 Tel +39 0426 921111 - Fax +39 0426 302222 www.blueboxgroup.it - info@blueboxgroup.it
12116000012_11.09