Sei sulla pagina 1di 2

" [ 1n 30] i

2" [ 50]

Typ.

Typ.

CONSTRUCTION METHODS
3"x3" [75x75] Mesh 16 gage steel hot galvanized wire cloth
8 " [ 2 0 0 ]

NOTES
MASONRY COLLARS: A masonry collar shall be provided where plans require that a pipe extension be joined to the end of an existing pipe with a butt joint. The cost shall be included in the unit price bid for the new conduit. EROSION CONTROL PAD AND ANIMAL GUARDS: These items shall be provided at the outlet end of all farm drains except where they outlet into a drainage structure. The steel bolts or rods for the animal guard shall be galvanized per CMS 710.06. In lieu of drilling or punching the " [13] diameter holes into the pipe, a metal collar meeting all of the above requirements may be clamped onto the pipe if approved by the Engineer. PAYMENT: Erosion control pads, masonry collars, and animal guards shall be included in the unit price bid for Item 603 - __ inch [mm] Conduit, Type __ . PRECAST REINFORCED CONCRETE OUTLET: The concrete outlet shall meet the requirements of CMS 604. 24" [600] PAYMENT: The precast reinforced concrete outlet shall be paid at the contract unit price bid for Item 604 Precast Reinforced Concrete Outlet. The Mortar; Tied Concrete Block Mat, Type 1, and Wire Mesh shall be included in the unit price bid for 601 - Tied Concrete Item Block Mat, Type 1. Tied Concrete Block Mat, Type 1 per CMS 601.12. Top to be flush with surface of the slope. 12" [300] min.
REVISIONS

STATE OF OHI DEPARTMENT OF TRANSPORTATI O ON

2" [50]

4"

" [6] Typ.

10"x10" #4 [250x250 #13M], U-Bar, Epoxy coated CMS 603 Conduit (4" or 6" [100 or150])

32" [800]

TOP VIEW
6" [150] " [6] Typ.

Mortar the void 28" [700] #4 [#13M] Straight Bar, Epoxy Coated as per CMS 604

" 8 4

m 2 . 1 [

4" [ 00] 1

1 6" [ 400]

#4 [#13M] U-Bar Epoxy Coated 2" [50]

[ 225]

9"

7-20-01 7-19-02 7-18-03 1-21-05 10-21-05 4-21-06


J Stai s . n
I MI N LLI METERS UNLESS

2" [ 0 5 ]

4 8 "

[ 25] 1

SIDE VIEW

FRONT VIEW PRECAST REINFORCED CONCRETE OUTLET

ALL METRI DI C MENSI ONS

( I BRACKETS [ ) ARE N ]

ROADWAY HYDRAULI C ENGI NEER

[ 1 . 2 m ]

5"

" [10] dia. Bolt or rod in " [13] dia. holes in pipe.

Erosion control pad

2" [50] 1" [25]

A
2 0" [ 600] Rod Pipe Brick Pipe " [13] min. 9" [225] grouted riprap or 6" [150] Class C concrete 1-6" [450] 2-0" [600] 6" [150] 1" [38] c/c Alternates

f cheek

STRUC TURA L

A
05- AUG- 2008 1 52PM :

[ 50] 1

concrete collar

PLAN

PROFILE
SEW ERS 1 D M -1. 1 2 O U T LE T S , D R A I S N A ND

EROSION CONTROL PAD AND ANIMAL GUARD FOR OUTLET PIPE


CONDUIT SIZE 4" Backfill as per CMS 603.10 125% of O.D., min. No. of Bolts 2

SECTION A-A
6" [150] 3 8" [200] 5 10" [250] 6 12" [300] 7 15" [375] 9 18"

MASONRY COLLAR

I \ pr Const ucton Dr : \ r i awi ngs\ SCD\ Hy aul dr i cs\ DM \ dm 1 _ apr 1 06_ v dgn 8.

11

5-0" [1524] Channel Invert 4" [100] min. 4" [100] min.

9" [225]

Pipe Invert 6" [150] Reinforced concrete slab Cutoff wall

O. D.

I D. .

CONCRETE CRADLE

6" [150] min. 4 18" [450] max. 6" [150] in rock

As per CMS 601.04.D, reinforce the slab approximately midway between the top and bottom of the slab, with steel bars or fabricated reinforcement equivalent to #3 [#10M] round bars, at 24" [600] o.c. in two directions, or wire fabric according to SCD BP-1.1.

Undisturbed soil

pi pe i ver n t

. . ID

6" [ 50] bel 1 ow

O. D .

2 6" [ 750] mi i n mum

RIPRAP CUTOFF WALL


The cost of the cutoff wall shall be included in the unit price bid for Item 601 Riprap using 6" [150] reinforced concrete slab.

9" [225]

Plain or reinforced concrete cradle, Class C

SCD NUMBER

STANDARD HYDRAULI CONSTRUCTI C ON DRAWI NG

[100]

[450]

6"

Class C

mi . n

CMS 603 Conduit

" [13] min.

O FFI E C

Brick

EN G I EERI G N N

OF

OTHERWI SE NOTED.

STATE HYDRAULI ENGI C NEER

[ 00] 1

4"

1 4" [ 350]

[ 00] 1

[ 50] 1

6"

[ 200]

8"

STATE OF OHI DEPARTMENT OF TRANSPORTATI O ON

NOTES
Precast reinforced concrete outlet 4" [100] min. 3 [900] min. Pay length SPRING DRAIN: Aggregates, tarred paper, tarred burlap, or geotextile fabric backfill and necessary excavation for spring drains shall be included for payment in the unit price bid per Foot [Meter] for Item 605, Aggregate Drains for Springs.

REVISIONS

3 [ 900]

PAYMENT: The pipe shall be included in the unit price bid per Foot [Meter] for 605 - 6" [150] Unclassified Item Pipe Underdrains for Springs. PRECAST REINFORCED CONCRETE OUTLET: The concrete outlet shall meet the requirements of CMS 604. PAYMENT: The precast reinforced concrete outlet shall be paid at the contract unit price bid for Item 604 Precast Reinforced Concrete Outlet. The Mortar; Tied Concrete Block Mat, Type 1; and Wire Mesh shall be included in the unit price bid for Item 601, Tied Concrete Block Mat, Type 1.

7-20-01 7-19.02 7-18-03 1-21-05 10-21-05 4-21-06

4" [100] min.

ALL METRI DI C MENSI ONS

Tarred paper, tarred burlap or Type B


f cheek

Geotextile Fabric per CMS 712.09.


d ae iih d r Fns e G

STRUC TURA L

Backfi l as per l

05- AUG- 2008 1 53PM :

per CMS 605.03.C

CMS 603. 0 1

Precast reinforced concrete outlet

I \ pr Const ucton Dr : \ r i awi ngs\ SCD\ Hy aul dr i cs\ DM \ dm 1 _ apr 1 06_ v dgn 8.

STANDARD HYDRAULI CONSTRUCTI C ON DRAWI NG

6" [ 50] 1

18" [450]

Tied Concrete Block Mat, Type 1. 48"x48" [1.2m x 1.2m]

Item 605, 6" [150] Unclassified Pipe Underdrains for Springs

SECTION A-A SPRING DRAIN DETAIL

D M -1. 1 2

SCD NUMBER

O U T LE T S , D R A I S N

A ND

SEW ERS

No. 57 or No. 467 Aggregate

2 6" [ 750]

6"

Granular filter as

O FFI E C

No. 8 Aggregate [ 50] 1

EN G I EERI G N N

OF

OTHERWI SE NOTED.

PLAN

I MI N LLI METERS UNLESS

( I BRACKETS [ ) ARE N ]

Tied Concrete Block Mat, Type 1. 48"x48" [1.2m x 1.2m]

J Stai s . n

Pipe Underdrain

ROADWAY HYDRAULI C ENGI NEER

STATE HYDRAULI ENGI C NEER