Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection
Ordering Information
Belden European Part Numbers
Fibre type / count 62.5/125-OM1 50/125-OM2 BW 600/1200 50/125-OM3 50/125-OM2e 50/125-OM2 BW 500/500 50/125-OM3+ 9/125 ITU G.655 9/125 ITU G.652D Std. plywood reel (non-returnable) Std. delivery length 4 GUWA104 GUWA204 GUWA304 GUWA404 GUWA504 GUWA604 GUWA704 GUWA804 6 GUWA106 GUWA206 GUWA306 GUWA406 GUWA506 GUWA606 GUWA706 GUWA806 8 GUWA108 GUWA208 GUWA308 GUWA408 GUWA508 GUWA608 GUWA708 GUWA808 12 GUWA112 GUWA212 GUWA312 GUWA412 GUWA512 GUWA612 GUWA712 GUWA812
Wooden reel 1000 * 585 mm, 47 kg Wooden reel 1400 * 900mm, 120 kg 2100 100m or 4100 100m
Applications
use in For outdoor and indoor and/or structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) horizontal cabling.. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Suitable for direct burial and / or in ducts, tunnels and trenches.
These cables Consequently are halogen-free (=FRNC and LSNH) and therefore suitable for both outdoor and indoor use. splicing can be avoided and the installation gets more cost-effective. A simple (central tube) cable construction and consequently more cost-effective up to 12 fibres then multi-tube cables with a Steel Wire Armouring.
Mechanical Data
No. of fibres Central tube (mm) Inner jacket, nom./max. (mm) Outer jacket, nom./max. (mm) Energy of flame (kJ/m) Weight (kg/km)
Optical Characteristics
Characteristics (cabled) Single-Mode Matched-Cladded optical fibres according to ITU.
European Partnumber Coding, Position 5 ModeField /Cladding Diameter (um) Attenuation average/ max. (dB/km) Cable Cut-off Wavelength (nm)
Fibre-Type
Wavelength (nm)
Dispersion (ps/(nm-km)
PMD (ps/km)
8 7
1260 1260
FibreType
Wavelength (nm)
Bandwidt h (MHzkm)
Refr. Index
1GBE
10 GBE
62.5/125 OM1 50/125 OM2 50/125 OM2 50/125 OM2e 50/125 OM3 50/125 OM3+
62.5 2.5 125 1 50 2.5 125 1 50 2.5 125 1 50 2,5 125 1 50 2.5 125 1 50 2.5 125 1
850 1300 850 1300 850 1300 850 1300 850 1300 850 1300
2.7 / 3.2 0.6 / 1.1 2.4 / 3.0 0.7 / 1.0 2.3 / 2.8 0.6 / 0.9 2,3 / 2,8 0,6 / 0,9 2.5 / 3.0 0.5 / 1.0 2.5 / 3.0 0.5 / 1.0
200 600 500 500 600 1200 600 1200 1500 500 6000 500
275 550 600 600 600 600 750 2000 900 550 900 550
0.275 0.015 0.20 0.015 0.20 0.015 0.20 0.015 0.20 0.015 0.20 0.015
1.495 1.490 1.481 1.476 1.481 1.476 1,481 1,476 1.482 1.477 1.482 1.477
5 2 4 3 6
Bending radii for fibres and tubes Installation/operation Watertightness according to IEC 60794-1-2-F5 Crush resistance according to IEC 60794-1-2-E3 Bending radii cable Static according to IEC 60794-1-2-E11 Dynamic according to IEC 60794-1-2-E6 Flame retardancy according to IEC 60332-3C (EN 50266-2-4) Halogen-free according to IEC 60754-2 (EN 50267-2-2) Corrosivity
When laying and installing optical fibre important not for pulling tension, bending radii and temperature.cables it is vitallymethods have toto exceed the specified values setstandards. The installation be in accordance with the common To insertion of compressed air or Theeaseof soap orinto tubes by meansas lubricants is strictlypulling wire, certified lubricants (e.g. paraffin) may be used. use similar substances prohibited. jelly filling inside the tubes can The advisable to cap the cable-endsbe removed using a tissue soaked in turpentine. It is during storage.
Options
Non-standard cable available on request. constructions, colours, details and/or additional information regarding specifications are
Revision
Rev. Description Date Init.
Page 1 of 1 Review:
Part Number:
GUWA