Sei sulla pagina 1di 94

Radcrete Pacific Pty Ltd

Contents
The Radcrete Waterproofing System
1.0.

Radcon Formula #7 Concrete Waterproofing For Above Grade Applications


Rooftops 1.1. 1.2. 1.3. 1.4. Car-Parks Bridges Water Holding Vessels Podium Decks Brochure Datasheet Specification Design Detailing 1.4.1. Planned Cold Joint 1.4.2. Unplanned Cold Joint 1.4.3. Cast In-Situ Hob 1.4.4. Planned Hob On Slab 1.4.5. Unplanned Hob On Slab 1.4.6. Planned Penetration 1.4.7. Planned Drain 1.4.8. Unplanned Penetration 1.4.9. Penetration After Pour 1.4.10. Movement Joint QA Checklist Site References 1.7.1. Car-Parks & Trafficable Applications 1.7.2. Water Retaining Structures 1.7.3. Bridge Applications 1.7.4. Rooftop Applications ISO 9002 Certificate CSIRO Appraisal Technical Assessment 193 MSDS

1.5. 1.6.

1.7. 1.8. 1.9. 2.0.

Radmyx Concrete Waterproofing For Below Grade Applications


Lift Pits 2.1. 2.2. 2.3. 2.4. Basements Retaining Walls Water Holding Vessels Landscaped Podium Brochure Datasheet Specification Detailing 2.4.1. Admixture Cold Joint 2.4.2. Admixture Wall/Floor 2.4.3. Admixture Penetration 2.4.4. Floor Repair 2.4.5. Wall/Floor Repair 2.4.6. Crack/Joint Repair 2.4.7. Honeycomb Repair QA Checklist Batch Check Draft Guarantee CSIRO Testing MSDS

2.5. 2.6. 2.7. 2.8. 2.9.

Radcon #7, Radmyx, Radguard & Radfloor are trademarks of Radcrete Pacific Pty. Ltd. & Radcrete Developments Pty. Ltd Page 1 of 2

Radcrete Pacific Pty. Ltd. 2000 A.C.N. 003 228 975 Radcrete Developments Pty. Ltd. 2000 A.C.N. 069 156 234 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Page 1+2 - Table of Contents.doc

3.0.

Radguard 3.1. 3.2. 3.3. 3.4.

Water Repellent For Concrete & Masonry Facades Pre-cast Panels Brickwork Stone Concrete Protection

Datasheet Specification Warranty MSDS

4.0.

Rx Waterstop Swelling Bentonite For Cold Joints & Penetrations


4.1. 4.2. Brochure Datasheet

5.0.

Radfloor Concrete Floor Hardening & Dustbinding


Car-parks
5.1. Datasheet

Factory Floor

Rain Damaged Slabs

5.2. 5.3. 5.4.

Specification Warranty MSDS

Radcon #7, Radmyx, Radguard & Radfloor are trademarks of Radcrete Pacific Pty. Ltd. & Radcrete Developments Pty. Ltd Page 2 of 2

Radcrete Pacific Pty. Ltd. 2000 A.C.N. 003 228 975 Radcrete Developments Pty. Ltd. 2000 A.C.N. 069 156 234 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Page 1+2 - Table of Contents.doc

Datasheet:
PRODUCT NAME
Radcon Formula #7

APPLICATION
Basic Requirements Radcon Formula #7 must be applied to a clean, dry, dustfree concrete surface, at least 28 days old. All curing compounds must have degraded or be removed prior to application. Any materials that retard penetration should be removed. Where segregation or voids are apparent, chip out, treat with Radcon Formula #7, then make good with cementitious materials. Good concrete practice must be followed such as adequate curing, compaction and vibration. Old or carbonated concrete requires a supplementary treatment to reinstate free calcium. 0 Do not apply where ambient temperatures are below +5 C or 0 above +40 C. Application Rates Normal: 1 litre to 5 square metres on average. Can vary depending on substrate sorptivity. For cracked areas: an additional 1 litre per 3 lineal metres is recommended. Method 1. Locate all cracks and flood with solution first ensuring they are filled with product. 2. Apply the solution to the remaining area at a rate of between 4-6 square metres per litre. 3. When surface becomes touch dry - (usually 2-6 hours depending on wind conditions and ambient temperature) flood spray the treated areas with water. If product still wet at 6 hours, begin first watering. 4. On Day 2 - 24 hours later water again. 5. On Day 3 - 24 hours later water again. 6. After the third watering, block drains and pond area for a minimum of 12 hours to verify a waterproof seal has been achieved.

MANUFACTURER
Radcrete Pacific Pty Ltd Level 3, 45a Bay Street Double Bay NSW 2028 SYDNEY AUSTRALIA e-mail: sales@radcrete.com.au web: www.radcrete.com.au Ph: +61-2-9362 3511 Fax: +61-2-9362 3244
ACN: 003 228 975 ABN: 30 003 228 975

DESCRIPTION

Radcon Formula #7 is a biochemically modified silicate solution that provides long-term waterproofing and durability benefits to concrete. It penetrates into concrete and reacts with free calcium and water to form a calcium silicate gel complex in cracks, pores and capillaries. This gel creates a sub-surface barrier against the ingress of water and contaminants such as chloride ions. Radcon Formula #7 will seal existing leaking cracks to 2.00mm. In the matrix the product remains reactive when in contact with water to provide autogenous healing properties to future hairline cracks.

TYPICAL APPLICATIONS
Rooftops & Podium Decks Car-parks Road & Rail Bridge Decks Wharf Decks & Marine Structures Airport Runways, Taxiways, Aprons Water Retaining Structures

SPECIALTY APPLICATIONS
Tiled areas (not terracotta or glass-glazed) Tiled shower recesses Facades Pre-cast elements & panels

PRECAUTIONS
Protect glass, aluminium, wood and painted finishes from overspray.

KEY BENEFITS
Long-term performance - No re-application or future maintenance required. 100% trafficable after the first watering. Minimal risk of damage during construction or thereafter. Fault finding - If stubborn cracks are present - easy to find and fix. No lifting of membranes required.

LIMITATIONS

Radcon Formula #7 is not suitable for sealing working/ volatile cracks as a result of structural defects or caused by mechanical damage. (See LARGE OR STUBBORN CRACKS) The product is not suitable for sealing where segregation and voids are likely such as construction joints, pour joints. Nor suitable around penetrations where there is a nonmasonry/cementitious interface. (See ANCILLARY DETAILING RECOMMENDATIONS) Radcon Formula #7 is not suitable for negative hydrostatic pressure applications such as the inside face of an basement/ retaining wall.

PERFORMANCE CHARACTERISTICS
Permanently seals cracks up to 2.00mm. Reseals future hairline cracking. Reduction of chloride diffusion coefficient by 89% to -12 2 3.5 (10 m /s). -12 Water permeability reduced by 70%/to 5.0 (10 m/s) at 2 10Kg/cm . Increases surface hardness from 6 to 8 on Mohs scale Reduces scaling in freeze-thaw environments by 89% at 50 cycles. Allows 84.1% moisture vapour permeability. Suitable for tanking applications (positive hydrostatic pressure) - tested to 400 metres. Non Toxic - Certified suitability for potable water.

CONCRETE
Mix Design Radcon #7 will meet or exceed its stated performance when applied to slag blend concrete and ordinary Portland cement Type GP concrete. Type C fly-ash replacement up to 30% of cement replacement. Type F fly-ash is not suitable for use with Radcon #7. Fall Lines Pour structural slabs to fall lines where possible. No protective screed is required.

Radcon Formula #7 is a registered Radcrete Pacific Pty Ltd 1999 trademark of Radcrete Pacific Pty Ltd. ACN 003 228 975 Specification details may change without notice. 4.4f6 26/11/01 All rights reserved Page 1 of 2 C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 09-10 - Datasheet pge 1+2.doc

CURING COMPOUNDS
Water curing is preferred. Aqueous Acrylics that degrade within 28 days are also suitable. Other materials such as chloro-rubber or wax emulsions require removal by grit blasting or grinding to allow the penetration of the product.

Radcon Formula #7 is available in 2ltr, 5ltr, 20ltr and 200ltr drums.

PACKAGING

SHELF LIFE & STORAGE


No known limit to shelf life. Keep container sealed and avoid prolonged exposure to direct sunlight. Always agitate drum or container before use.

DETAILING REQUIREMENTS
For more extensive information, please refer to the Radcon #7 specification or design detailing sheets. Construction/Pour Joints The joint should be formed by a vertical stop board during construction. Use bentonite waterstops in construction joints. The alternative is the application of a reinforced liquid applied membrane stripseal extending 100mm either side over the top of construction joints where covered, or grind and fill with nonshrink grout or polymer modified grout, or elastomeric joint sealing compound if there is risk the joint will move. Upturns/Hobbs First preference is having upturns/hobs poured in-situ or bentonite waterstop places in joint. Next alternative is to stripseal the cold joint between upturn and slab with reinforced liquid applied membrane extending 100mm either side. Penetrations Use bentonite waterstops or reinforced liquid applied membrane extending 100mm around penetrations, drains, fulgo inlets etc. Expansion Joints Responsibility of others Control Joints Create a joint extending the depth of the slab, prior to drying shrinkage of the concrete. Use an elastomeric joint sealing compound to seal the joint.

TECHNICAL SERVICES
Complete technical information including testing data and detailing is available from Radcrete Pacific and authorised distributors. Refer to the web site for specification information or e-mail radcrete.

GUARANTEES

15 year guarantees for Radcon Formula #7 treated areas are available where approved applicators are used and in appropriate situations. Contact the manufacturer for further information and confirmation of suitability.

APPROVALS & TESTING


ABSAC Technical Opinion No.193 Building Research Centre (UNSW) Condition Survey Building Research Centre (UNSW) Laboratory Evaluation ISAT to BS 1881 Water Permeability Chloride Ion Diffusion (Taywoods) US Highway Dept (USA) Bridge Deck Surface Treatments Adhesion of Asphalt to treated surface Resistance to Water Absorption Freeze-Thaw Scaling Resistance Effect of Hot (160oC) Asphalt on treatment Effect of Outgassing on material Outdoor test Warnock Hersey (Canada) Depth of Penetration Water Absorption Vapour Permeability Chloride Ion Penetration Freeze-Thaw with Deicing Salts Chemical Resistance Slip Resistance Viscosity Non-Volatile Contents Relative Density pH Value Hardness Test SINTEF (Norway) Permeability - 400m head of pressure Chloride Ion Diffusion -wetting/drying SISIR (Singapore) Non-Toxicity Potable Water Certification CSIRO Depth of Penetration

LARGE OR STUBBORN CRACKS


Create a small dam and flood crack with product, repeating the application process. A liquid, fine grind cement slurry can be used in large, stable cracks. 5:1 ratio of water:cement. Consult Radcrete for the latest techniques and where cracks are volatile.

MAINTENANCE
None required.

INTERNATIONAL REPRESENTATIVES
Asia/Pacific: Australia, Guam, Hong Kong, Indonesia, Japan, Malaysia, New Zealand, Philippines, Singapore, Sri Lanka, Taiwan, Thailand, Vietnam. Europe: Belgium, Estonia, Italy, Norway, Spain, Portugal, Russia North America: Bermuda, Canada, USA, Caribbean Middle East: Lebanon South America: Brazil

SPECIFICATIONS

See Radcon Formula #7 Specification at www.radcrete.com

PRODUCT PROPERTIES
Colourless, clear to slightly opaque, odourless, soapy feel. Non-toxic & Biodegradable Percent non-volatile solids: 27.7% 0 Specific gravity at 25 C: 1.225 0 Flash point - no true flash - boils at 101 C Auto ignition temperature - N/A Non-explosive Viscosity - 14.3 centipoise or 0.1172 Stokes Hazardous chemicals - Sodium Silicate (modified) pH 11.7

FURTHER INFORMATION

HEALTH NOTES
Eye Exposure - Severe irritation. Flush with large amounts of water. Skin - No known ill effects have been noted however, with chemicals, one should always avoid contact with skin.

IDENTIFICATION CODES
Australian Adchem Code - Material 15660 USA Manufacturers Code C 101

Radcrete Pacific Pty Ltd ISO 9002:1994 Level 3, 45a Bay Street Reg#1042 Double Bay NSW 2028 SYDNEY AUSTRALIA Ph: +61-2-9362 3511 Fax: +61-2-9362 3244
ACN: 003 228 975

Note: The information presented is intended guide only and is correct to the best of our knowledge at the time of publication. It should not be considered as a definitive approval for suitability for a particular purpose. Please contact the manufacturer, distributor or approved applicator for confirmation of suitability. Ancillary detailing recommendations are provided in good faith to assist in achieving final waterproof result. We accept no liability for those recommendations or those products performance in use.

Radcon Formula #7 is a registered Radcrete Pacific Pty Ltd 1999 trademark of Radcrete Pacific Pty Ltd. ACN 003 228 975 Specification details may change without notice. 4.4f6 26/11/01 All rights reserved Page 2 of 2 C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 09-10 - Datasheet pge 1+2.doc

Instructions to Specifier. Append the following Specifications and Drawings to tender and contract specifications.

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd. Page 1 of 5

Radcrete Pacific Pty Ltd 2000 ACN 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 11-14 - Instructions to Specifier.doc

SUB SURFACE MEMBRANE WATERPROOFING


1 1.1 GENERAL SCOPE This specification describes a subsurface membrane waterproofing system by means of a solution that penetrates and integrates with the concrete surface. Proprietary item: Radcon Formula #7 Waterproofing System Supplier: Radcrete Pacific Pty Ltd. 1.2 RELATED DOCUMENTS Refer drawings, Preliminaries, Bill of Quantities, General Requirements, and general provisions of the contract. RELATED WORKS SPECIFIED ELSEWHERE Concrete mix design, placement, curing, finishing, joint preparation and detailing affect this section and are included within this specification. REFERENCES Radcrete test procedures RT01 Depth of penetration into substrate RT02 Cracks sealing and resealing on test rig RT03 Reduction of Chloride Diffusion Co-efficient 2 2.1 QUALITY SUBMISSIONS Approval before application Submit a detailed statement describing the concrete waterproofing system to be applied. Inclusions Include literature, details, samples, warranties and the like in the submission as required. Provide the manufacturers or nominated agent/distributors written acceptance and approval of the intended system required. 2.2 QUALITY ASSURANCE Approved applicators Use applicators approved and licensed by the manufacturer or their nominated agent/distributor. Site inspection The approved applicator must inspect the site prior to commencment of application of the system, for purposes of reviewing related conditions affecting the performance requirements of this specification. Safety The site foreman/supervisor shall sight and understand the site specifications and product datasheets. All products described in this section must be used with adequate personal protection as recommended by the Material Safety Datasheet which accompanies each product shipment.

1.3

1.4

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd. Page 2 of 5

Radcrete Pacific Pty Ltd 2000 ACN 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 11-14 - Instructions to Specifier.doc

3 3.1

MATERIALS AND COMPONENTS MATERIAL Waterproofing system Provide a waterproofing solution that creates a vapour permeable sub-surface barrier to prevent water leakage and ingress of contaminants into the cracks and concrete matrix. Provide a solution that penetrates into concrete and reacts with Calcium Hydroxide and water at ambient temperatures to form a non water soluble complex calcium silicate hydrate gel in the cracks pores and capillaries. Material Provide a solution that is a non-toxic, clear, odourless silicate based material with proprietary biochemical modification. Cracks The product must seal existing leaking cracks up to 2.00mm in structural concrete. In the matrix, it shall remain reactive with water to provide autogenous healing properties to future hairline cracks to 0.3mm.

4 4.1 4.2

CONCRETE & RELATED DETAILING CONCRETE MIX DESIGN Radcon #7 treatment is suitable for Portland Cement Mixes only. CONCRETE INSTALLATION Insitu concrete Ensure that the concrete is properly compacted by vibration and adequately cured for at least 28 days prior to the application of the material. Falls Pour concrete with fall lines to drains

4.3

CONCRETE FINISH Preferred finishes Use wood float or broom finish. Steel float Where steel trowel/helicopter float is used, open surface pores by acid etching, grinding or blasting.

4.4

CURING Water cure where possible for 7 days If curing compounds are used degrade or remove prior to application.

4.5

CONSTRUCTION/POUR JOINTS Construction joints/pour joints Provide a vertical stop board at all construction/pour joints. Pour breaks Roughen construction joint face to expose aggregate so as to provide an adequate key for the new concrete slab to be poured. Waterstops Install Volclay Waterstop RX as per manufacturers recommendations. Apply with the manufacturers Approved Applicator (refer to RPJ1 below)

4.6

UPTURNS AND PARAPETS First preference Treat slab with the material prior to pouring parapet (refer to BM1 below)
Radcrete Pacific Pty Ltd 2000 ACN 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 11-14 - Instructions to Specifier.doc

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd. Page 3 of 5

Second preference Pour parapets in-situ (refer to RPJ4 below) Third preference Install Volclay Waterstop RX in the parapet joint (refer to RPJ5 below) Final preference Apply reinforced liquid membrane strip seal (refer to RPJ6 below) 4.7 DRAINS & PENETRATIONS Prior to concrete pour Install Volclay Waterstop RX as per manufacturers recommendations around penetrations. (refer to RP1 below) Drains Where drains are installed, install either Volclay Waterstop RXoor liquid applied membrane recessed into the drain. (refer to RP3 below) Waterstops Where Volclay Waterstop RX is not installed prior to pour, install liquid applied membrane stripseal around penetration. (refer to RP5 below) Holes Where holes are cored into the slab and penetrations placed afterwards, use non-shrink grout to fill the space between penetration and the slab, then utilise liquid applied membrane strip-seal. (refer to RP6 below) 5 5.1 EXECUTION APPLICATION AND SUPERVISION General Install the system in accordance to manufacturers' published recommendations. Personnel Employ trained applicators. Tools and equipment Use proper tools and equipment and working under the direct supervision of a technically competent and experienced supervisor. 5.2 SURFACE PREPARATION Remove all dags, laitance and loose fines by scraping or grinding. Remove all materials that may retard penetration such oil, grease, and paints. Hack out all holes, areas of honeycombing, and damaged sections. Treat with material. When touch dry, patch with a suitable cementitious grout, and trowell to a smooth even finish. Allow overnight drying. Clean down surfaces thoroughly by water blaster to remove dirt, dust, or other contamination to leave sound clean surfaces free of residues. Ensure that the surface is dry at end of surface preparation. 5.3 ENVIRONMENT CONDITIONS Do not apply the material When ambient temperatures are below +5oC or above +40oC. When rain is imminent. In high wind conditions.

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd. Page 4 of 5

Radcrete Pacific Pty Ltd 2000 ACN 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 11-14 - Instructions to Specifier.doc

5.4

CRACKS General Locate all cracks and flood with the material. Ensure that all cracks are filled with product. Coverage rate Allow 1 litre per 3 lineal metres.

5.5

GENERAL AREAS Coverage rate Apply the material to the remaining area at a coverage rate of between 4-6 sq. meters per litre. WATER FLOOD TREATMENT When surfaces have become touch dry - (usually 2-6 hours depending on wind conditions and ambient temperatures) and no longer than 6 hours, flood spray the treated areas with water for the first day. Repeat the flood spraying for the next 2 subsequent days.

5.6

6 6.1

QUALITY CHECK AND COMMISSIONING WATER TEST AND VERIFICATION On completion Provide the following tests after treatment and ancillary detailing has been completed. Water tests Pond or water test the area for a minimum of 12 hours to verify the treated area is watertight. If leakage occurs, note and isolate area then treat again. Watertightness must be verified before a guarantee is issued Surface penetration For further quality control, random core samples can be taken to be analysed using SEM & EDS to determine penetration according to test method RT01.

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd. Page 5 of 5

Radcrete Pacific Pty Ltd 2000 ACN 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 11-14 - Instructions to Specifier.doc

yy @@yy ;;;; yy @@ ;; yyyy ;;;; y ; yy @@ ;; yy @@ ;;


Design Detailing:
Planned Cold Joint
Instructions: 1) 2) 3) 4) 5) Finish Pour with vertical stop board ensure vibration to edge of board. Install Volclay RX waterstop. Apply Radcon Formula #7 or use Radmyx as sprinkle on cold joint face. Pour concrete. Apply Radcon Formula #7.
Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty. Ltd. Page 1 of 1 Radcrete Pacific Pty. Ltd. 1998 A.C.N. 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 15 - Detail - Planned Cold Joint.doc

yy @@ ;; yyy yy ;;; ;; y ; yyy ;;; y ; yyy @@@yy ;;;;; yy @@ ;; yyy @@@ ;;; yy @@ ;;
Design Detailing:
Unplanned Cold Joint
Instructions: 1) 2) Apply membrane strip seal over joint.. Apply Radcon Formula #7.
Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty. Ltd. Page 1 of 1 Radcrete Pacific Pty. Ltd. 1998 A.C.N. 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 16 - Detail - Unplanned Cold Joint.doc

Design Detailing:
Cast In-Situ Hob

Instructions: 1) 2) 3) 4)

Cast Hob in-situ. Apply Radcon Formula #7 in hob cold joint. Pour concrete wall/parapet. Apply Radcon Formula #7.

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty. Ltd. Page 1 of 1

Radcrete Pacific Pty. Ltd. 1998 A.C.N. 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 17 - Detail - Cast in Situ Hob.doc

yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;;

y @ ; yyy @@@ ;;; y @ ;


yy ;; yy ;; yyyyyy ;;;;;; yyyyyy ;;;;;; yyyyyy ;;;;;; yyyyyy ;;;;;;

Design Detailing:
Planned hob on slab

Instructions: 1) 2) 3) 4) 5)

yyy @@@ ;;; yy @@ ;;


Cast slab. Clean surface and apply RX waterstop. Apply Radcon Formula #7 or Radmyx as sprinkle prior to pouring hob. Pour concrete wall/parapet. Apply Radcon Formula #7.
Radcrete Pacific Pty. Ltd. 1998 A.C.N. 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 18 - Detail - Planned Hob on Slab.doc

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty. Ltd. Page 1 of 1

yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;;

y;; ;yy yyy ;;; yyyyyy ;;;;;; yyyyyy ;;;;;; yy ;; yy ;;

Design Detailing:
Unplanned hob on slab

Instructions: 1) 2) 3) 4)

Cast slab. Cast concrete wall/parapet. Apply reinforced liquid membrane bandage to joint area. Apply Radcon Formula #7.

yyy @@@ ;;; y @ ;

Radcon Formula #7 is a registered Radcrete Pacific Pty. Ltd. 1998 trademark of Radcrete Pacific Pty. Ltd. A.C.N. 003 228 975 Page 1 of 1 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 19 - Detail - Unplanned hob on slab.doc

yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;;

yyy ;;; yyy ;;; yyyyyyy ;;;;;;; yy ;; yy ;; yyyyyyy ;;;;;;; y ; yy ;;

Design Detailing:
Planned penetration

yyyyy ;;;;; yyyyy ;;;;;

yyy @@@ ;;;


Radcrete Pacific Pty. Ltd. 1998 A.C.N. 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 20 - Detail - Planned Penetration.doc

Instructions: 1) 2) 3) Install RX waterstop around penetration. Cast concrete slab. Apply Radcon Formula #7.

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty. Ltd. Page 1 of 1

Design Detailing:
Planned penetration

yyyyy ;;;;; yyyyy ;;;;;

yyy @@@ ;;;


Radcrete Pacific Pty. Ltd. 1998 A.C.N. 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 20 - Detail - Planned Penetration.doc

Instructions: 1) 2) 3) Install RX waterstop around penetration. Cast concrete slab. Apply Radcon Formula #7.

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty. Ltd. Page 1 of 1

Design Detailing:
Unplanned Penetration

yyyyyyy ;;;;;;;
Instructions: 1) 2) 3) Install RX waterstop around drain. Cast concrete slab. Apply Radcon Formula #7.
Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty. Ltd. Page 1 of 1 Radcrete Pacific Pty. Ltd. 1998 A.C.N. 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 22 - Detail - Unplanned penetration.doc

y yy @ @@ ; ;; y yy @ @@ ; ;;
yy y ;; ;

yyyy ;;;; y @@ @ ;; ; yy yyy @@ ;;; ;; y ; yy ;; y @ ; yy


Design Detailing:
Penetration after pour

yy y ;; ;

Instructions: 1) 2) 3)

4) 5)

Cast concrete slab. Cut hole and install penetration. Grout space between hole and penetration with non-shrink grout. Ensure backer rod used at bottom of hole to avoid loss of grouting. Apply reinforced liquid membrane to penetration/ grout / concrete interface. Apply Radcon Formula #7.

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty. Ltd. Page 1 of 1

y ;

Radcrete Pacific Pty. Ltd. 1998 A.C.N. 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 23 - Detail - Penetration after pour.doc

y ;

yyy @@@ ;;; yyy @@@ ;;; yyy @@@ ;;; yyy @@@ ;;;
Design Detailing:
Movement Joint
Instructions: 1) 2) Apply elastomeric joint sealant. Apply Radcon Formula #7.
Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty. Ltd. Page 1 of 1 Radcrete Pacific Pty. Ltd. 1998 A.C.N. 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 24 - Detail - Movement joint.doc

y ;

yyyyy yyy ;;;;; ;;; y ;

QA Checklist:
This Checklist is to be completed in full so that a Radcon Formula #7 guarantee can be issued to your site.

SITE INFORMATION
Project Name:________________________________________ Site Address: ________________________________________ ____________________________________________________ ____________________________________________________ Building Contractor: ___________________________________ ___________________________________________________ ___________________________________________________ Date of Practical Completion: ___________________________ Client Details: ___________________________ _______________________________________ _______________________________________ _______________________________________ Site Contact: ____________________________ Site Phone: ____________________________

Project No: __________

APPLICATION
Approved Applicator: ______________________________________________________________________________ Areas Treated: (DECK, WATER HOLDING VESSEL, OTHER) ___________________________ SQM: _______________

Attached are Checklists for each application. One should be filled out per area. _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _______________ _______________ _______________ _______________ _______________

SUPERVISION (NOT ESSENTIAL FOR ALL JOBS WHEN APPROVED APPLICATOR USED)
Name: -------------------------------------------Guarantee to made out to the: Signature: --------------------------------BUILDER CLIENT Date: ----------------------------------(TICK ONE)

CHECKLIST
Different checklists have been prepared for different applications of Radcon Formula #7. Please fill in the correct form depending on the type of application (ie. suspended deck, water holding vessel). If there are multiple areas of, for example, suspended decks, then one form should be filled out for each logical area. This section must be completed in full before a guarantee will be issued for a site. For clarification of any of the points detailed below please refer to the Radcon Formula #7 Datasheet and Specification.

SITE COMMENTS

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd. Page 1 of 3

Radcrete Pacific Pty Ltd 2000 ACN 003 228 975 4.4f8 08/01/02 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 25-27 - QA checklist.doc

SUSPENDED DECKS
Plan Ref. No. ___________________________________________ Name of Area: __________________________________________ CONCRETE INSTALLATION Check concrete mix design
(ORDINARY PORTLAND CEMENT ONLY - ATTACH MIX DESIGN)

Completion of Works: _____________________ Square Metres: __________________________ Comments

Check

Initial

Check Concrete Pour.


(LOOK FOR HONEYCOMBING)

Check construction joint detailing.


(WHERE APPROPRIATE)

Check correct fall lines. Check curing compounds removed. RADCON FORMULA #7 APPLICATION Check Security Seals. Check Batch Number.
(INCLUDE NO. IN COMMENTS COLUMN)

Check

Initial

Comments

Amount Litres used on site


(1 LITRE PER 5 SQM APPROXIMATELY)

Check Substrate Preparation.


(DRY & CLEAN)

Shrinkage Cracks Visible. Cracks Through Slab. Straight Line Cracks Present. Check application to cracks.
(TAPE UNDERSIDE OF CRACK IF LEAKING OCCURS

Check Radcon Formula #7 Application to Substrate Check Radcon Formula #7 Drying Time (2 - 6 hrs) Check 1 Watering. Check 2 Watering. Check 3 Watering. Check Seal - Flood Test.
(MINIMUM 12 HOURS)
rd nd st

Check Ancillary Detailing


(LIST SCOPE OF WORKS & PRODUCT NAMES)

1. Cold joints 2. Construction joints 3. Expansion joints 4. Penetrations Radcrete Pacific Representative: Print Name: _______________________________________ Approved Applicator: Print Name: _______________________________________ Clients Representative: Print Name: _______________________________________ Position: __________________________________________ Signature: _________________________________ Date: __________ Signature: _________________________________ Date: __________ Signature: _________________________________ Date: __________

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd. Page 2 of 3

Radcrete Pacific Pty Ltd 2000 ACN 003 228 975 4.4f8 08/01/02 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 25-27 - QA checklist.doc

WATER HOLDING VESSEL


Plan Ref. No. ___________________________________________ Name of Area: __________________________________________ CONCRETE INSTALLATION Check concrete mix design
(ORDINARY PORTLAND CEMENT ONLY - ATTACH MIX DESIGN)

Completion of Works: _____________________ Square Metres: __________________________ Comments

Check

Initial

Check Concrete Pour.


(LOOK FOR HONEYCOMBING)

Check construction joint detailing.


(WATERSTOPS PREFERRED)

Check correct fall lines. Check curing compounds removed. RADCON FORMULA #7 APPLICATION Check Security Seals. Check Batch Number.
(INCLUDE NO. IN COMMENTS COLUMN)

Check

Initial

Comments

Amount Litres used on site


(1 LITRE PER 5 SQM APPROXIMATELY)

Check Substrate Preparation.


(DRY & CLEAN)

Shrinkage Cracks Visible. Cracks Through Slab. Straight Line Cracks Present. Check application to cracks.
(TREAT VERTICAL CRACKS TWICE FOR CAPILLARY DRAW)

Check Radcon Formula #7 Application to Substrate Check Radcon Formula #7 Drying Time (2 - 6 hrs) Check 1 Watering. Check 2 Watering. Check 3 Watering. Check Seal - Flood Test.
(MINIMUM 12 HOURS)
rd nd st

Check Ancillary Detailing


(LIST SCOPE OF WORKS & PRODUCT NAMES)

1. Cold joints 2. Construction joints 3. Expansion joints 4. Penetrations

Radcrete Pacific Representative: Print Name: _______________________________________ Approved Applicator: Print Name: _______________________________________ Clients Representative: Print Name: _______________________________________ Position: _______________________________________ Signature: _________________________________ Date: __________ Signature: _________________________________ Date: __________ Signature: _________________________________ Date: __________

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd. Page 3 of 3

Radcrete Pacific Pty Ltd 2000 ACN 003 228 975 4.4f8 08/01/02 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 25-27 - QA checklist.doc

SITE REFERENCE
Car-parks and Trafficable Applications
SEACON SQUARE SHOPPING CENTRE, THAILAND Location: Developer: Architects Proj. Managers: Builder: Applicator: Size: Description: Bangkok, Thailand Seacon Development Co. Ltd CASA/Design & Develop PRO 8 Italian Thai Dev. Corp. Ltd. Radcon Thailand Co. Ltd. 50,000 square metres 5th largest shopping centre in the world. Trafficable rooftop car-park deck. Client: Engineers: Applicator: Application: Size: Description: Westfields Design & Construct MPN Group (NSW) Pty. Ltd. All Ready Surfacing Pty. Ltd. Rooftop/car park 1,600 sqm Shrinkage cracking in stressed deck..

GARDEN CITY KOTARA SHOPPING CENTRE, AUSTRALIA Location: Client: Engineer: Main Contractor: Size: Description: Kotara Newcastle 2289 Resolve Engineering - AMP Prop.Management Acer Wargon Chapman Pty. Ltd. Civil & Civic 6,500 sqm Remedial application. Major cracks, early formwork stripping was believed to be the cause. Epoxy injection, membrane bandages and other methodologies had been used unsuccessfully. Some cracks were ground & filled due to large size and epoxy residues. Seal confirmed. After application Newcastle earthquake caused new cracking. 90% resealing. Radcon #7 reapplied to leaking cracks and the deck has remained sealed.

WESTFIELD SHOPPING CENTRE, AUSTRALIA Location: Specification: Engineers: Treatment Date: Area Treated: Description: Mount Druitt NSW 2770 Westfield Design & Construct MPN group (NSW) Pty. Ltd. June 1995 8,770 sqm Car-park deck over shopping.

1 UTAMA SHOPPING CENTRE, MALAYSIA Location: Owner: Architect: Main Contractor: Engineers: Anchor tennant: Application: Size: Description: Kuala Lumper, Malaysia Semba Corp. Tokyo C.T. Architect FNE - Obayashi Consortium Perunding Talico Jaya Jusco Rooftop car park over retail 46,000 sqm New slab over precast panel construction

DANDENONG SHOPPING CENTRE, VICTORIA Location: Engineer: Project Manager Developer: Applicator: Treatment: Area Treated: Description: Dandenong VIC 3175 Elden Smith Construction Engineering Thompson Land Baker Technical Services September 1989 6,000 sqm trafficable areas were specified Radcon #7. 6,000 sqm of critica

KOWLOON CITY PLAZA, HONG KONG Location: Developer: Engineers: Applicator: Application Size: Description: Hong Kong Pailiburg Development Chatwin Engineers Wong Fu & Co. Rooftop/car park exposed 10,000 sqm New construction with shrinkage cracking before and after application.

BHP CAR-PARK, MELBOURNE Location: Specification: Application: Treatment Date: Area Treated: Description: Melbourne VIC 3000 Irwin Johnson & Partners Hitec Waterproofing May 1991 4,000 sqm Severe 2-3mm cracks above t-beams.

MACQUARIE SHOPPING CENTRE, SYDNEY Location: Client: Architect: Engineer: Main Contractor: Applicator: Application: Size: Description: Ryde NSW 2112 AMP Property Management RJ Thrum & Associates Pty. Ltd. Hyder Consulting (Acer Wargon Chapman) Concrete Constructions Pty. Ltd. Kratrim Pty. Ltd. Rooftop/car park over supermarket 5,000 sqm New Construction, stressed decks with

MICROSOFT HEAD OFFICE, SYDNEY Location: Architect: Main Contractor: Applicator: Application: Size: Description: Epping NSW 2121 Rice Daubney Pty. Ltd. Triden Contractors Kratrim Pty. Ltd. Rooftops, podium decks covered tiles, pre cast panel retaining walls and plant rooms. 7,000 sqm New Construction, trafficable car park and podium.

DUTY FREE SHOPPING STORE, GUAM Location: Main Contractor: Applicator: Application: Size: Description: Guam, Micronesia Fletcher Pacific JT Developments Rooftop exposed 6,000 sqm New Construction with shrinkage cracks.

BULLS HEAD CAR PARK, BERMUDA Location: Client: Applicator: Application: Size: Description: Hamilton, Bermuda Bermuda Council Parker Ltd. Car park exposed 20,000 sqm New Construction on Bond-deck system.

WHITFORD SHOPPING CENTRE, AUSTRALIA Location: Perth WA 6000

KLOSTER FORD, NEWCASTLE

Radcon #7 is a registered Radcrete Pacific Pty Ltd trademark of Radcrete Pacific Pty Ltd A.C.N. 003 228 975 Page 1 of 3 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 28-31 - Site Ref - Car Parks & Trafficable.doc

KIKUGAOKAOKA APARTMENTS, JAPAN Location: Client: Applicator: Application: Size: Description: Hamilton NSW 2303 Kloster Ford Massey Building Services October 1989 1,200 sqm Required the removal of a trafficable membrane over service dept. Seal was verified 2 months prior to the Newcastle earthquake of December 1989. The earthquake caused 12 leaking cracks in the first rain period with widths to 1mm. Within 3 days the cracks had resealed after initial leakage. The product performance on site was over and above specification and what could generally be expected. Location: Developer: Application: Size: Description: Tokyo, Japan Towa Real Estate Radcon Japan 1,500 sqm New Construction - Multideck car-park.

ROYAL HONG KONG JOCKEY CLUB CAR PARK Location: Client:: Main Contractors: Application: Description: Size: Hong Kong Royal Hong Kong Jockey Club Franki Contractors (Bilfinger + Berger) Wong Fu. & Co. New Construction - Multideck car-park. 5,000 sqm

PHOENIX SHOPPING CENTRE, PERTH Location: Specifier: Applicator: Treatment Date: Area Treated: Description: Perth WA 6000 Armstrong Jones Aquaseal Technologies May 1992 9,369 sqm Deck showed very bad cracking and leakage was profuse. Some spalling evident on underside where there was little cover.

CIRCIUMA BUS DEPOT, BRAZIL Location: Main Contractors: Application: Engineer Description: Size: Brazil Construtora Cavaler Ltda Lienge Construtora Ltda Sabadin New bus depot podium and retaining wall with shopping centre enclosed below 3,500 sqm

LUNA PARK, SYDNEY Location: Specifier: Treatment Date: Area Treated: Description: McMahons Point NSW 2060 Taylor Thomson & Whiting June 1994 1,800 sqm Slab supporting roller coaster in chrolride environment.

THE GLEN SHOPPING CENTRE, MELBOURNE Location: Engineer: Architect: Main Contractors: Application: Description: Size: Melbourne VIC 3000 Connell Wagner Hames Sharley Baulderstone Hornibrook Higgins Coatings Extensions to shopping centre - suspended car park and loading dock areas 7,000 sqm

ST. GEORGE PUBLIC HOSPITAL, SYDNEY Location: Engineer: Builder: Client: Area Treated: Date Completed: Description: Kogarah NSW 2217 Leighton Irwin Pty. Ltd. John Holland Constructions NSW Health Department 3,000 sqm December 1992 New Car-park rooftop and podium deck.

SUPA CENTRE, SYDNEY Location: Engineer: Main Contractors: Application: Description: Size: Homebush NSW 2140 Acer Wargon Chapman Southern Cross Constructions Multitech Sealants and Waterproofing Extensions to Shopping Centre - Rooftop carpark 5,000 sqm

UNIVERSITY OF WOLLONGONG CAR PARK Location: Specification: Application Treatment Date: Area Treated: Description: Wollongong NSW 2500 Acer Wargon Chapmen Kratrim Pty. Ltd. July 1994 2,100 sqm Flat bed engineered car-park with plastic settlement cracking over columns to 2mm.

PLAZA SENAYAN SHOPPING CENTRE, JAKARTA Location: Architect: : : Main Contractors: Application: Description: Size: Jakarta, Indonesia RTKL, USA (Design Architect) Kajima Design (Cooridinating Architect) PT Airmas Asri (Project Architect) Kajima Overseas Asia - Waskita PT Argacipta Cemerlang Car park decks 6,000 sqm

URAYSU CITY INDUSTRIAL WASTE DISPOSAL PLANT Tokyo, Japan Nishimatsu Contractors Radcon Japan December 1994 7,000 sqm New construction with cracked decks and facades. Trafficable decks for trucks and heavy equipment. Regular heavy washing for cleaning. Concrete protection benefits also relevant. TAK -101, Y0KOHAMA, JAPAN Location: Specification: Construction: Application: Size: Description: Yokahama, Japan M Planning Co Ltd Nishimatsu Contractors Radcon Japan 8,000 sqm New Construction - multideck car-park. Location: Specification: Application Treatment Date: Area Treated: Description:

N3 SUPERBLOCK CAR PARK, TANGERANG, INDONESIA Location: Owner: Architect:: Main Contractors: Application: Description: Size: Tangerang, Indonesia LippoLand Development Crone & Associates - Australia Inti Surya - Wijaya Kusuma Contractors (JV) PT Argacipta Cemerlang Car park decks 5,000 sqm

KODAK HOUSE, HONG KONG Location: Developer: Applicator: Application: Completed Hong Kong Sun Hung Kai Properties Wong Fu & Co. Podium deck, car-park 1990

Radcon #7 is a registered Radcrete Pacific Pty Ltd trademark of Radcrete Pacific Pty Ltd A.C.N. 003 228 975 Page 2 of 3 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 28-31 - Site Ref - Car Parks & Trafficable.doc

Size:

1,500 sqm

MAIA SHOPPING CENTRE, PORTUGAL Location: Client: Engineer: Architect: Builder: Application: Size: Portugal Sonae SA Forjadus Castello (Spain) Nuclarq SA Hellmuth Obata & Kassa Baum Inc, USA Contacto SA Coala SA 12,500 sqm

GARDEMOEN AIRPORT, NORWAY Location: Client: Construction Applicator: Application: Completed Size: Gardemoen, Norway Gardemoen Airport EEK Henricksen Betongforshiling Radcon/Radfloor system car-park decks June 1998 54,000 Sqm

NORTHSIDE HOSPITAL, ATLANTA, USA HANOI CENTRAL HOTEL, VIETNAM Location: Client: Specifier: Contractor: Applicator: Areas Treated: Size: Hanoi, Vietnam SAS Ctamad Taylor Thimpson Whitting Bilfinger & Berger Radcon Vietnam All car park decks Location: Client: Engineer: Application: Size: Atlanta, USA Northside Hospital Sedki & Russ Lee Inc. 5,000 sqm

SHIMIZU CORPORATION: 3 STOREY CAR PARK, JAPAN. Location: Client: Contractor: Specifier: Application: Size: Japan Shimizu Corporation Kawasaki Kizai Co. Ltd. Kokusai Kogyo Co. Ltd. Rad Japan 2,000 sqm

LAKE GARDA CAR PARK, ITALY Location: Date of Application: Application: Applicator: Size: Malcesine, Italy All carpark areas Tecnocoat Trento 6,000 sqm

OLYMPIC VILLAGE, RUSSIA Location: Builder: Application: Areas Treated: Completed: Size: Moscow, Russia. Mosmetrostroi, SMU-8 PSM Service Limited Underground carpark below tennis centre April 1988 7,400 sqm

MACQUARIE CENTRE STAGE 1 SYDNEY Location: Client: Engineer: Contractor: Application: Size: North Ryde, Sydney. AMP Asset Management Hyder Consulting Pty Ltd. Fletcher Consructions Pty Ltd Waterproofing new car park deck 2,200 sqm

ST LEONARDS CORPORATE CAR PARK, SYDNEY Site Details Location: Client: Engineer: Applicator: Application: Size: Description: St Leonards NSW 2065 State Super Board Ray Condon Consulting Engineer Kratrim Pty. Ltd. Car park deck exposed 2,000 square metres 300 lineal metres of cracks averaging 1.2mm treated in 1988 Part of Radcon #7 ABSAC Appraisal for Government projects in Australia. Report available upon request. This site is a four level car park with normally reinforced concrete decks. It was Radcon #7 first major car park sealing job undertaken with severe leakage evident. A total of 300 lineal metres of leaking cracks ranging from 0.5mm - 2.5mm in width were evident prior to treatment. Radcon #7 was treated to the entire top level which is completely exposed. The treatment was a complete success, however some major cracks required two or three treatments to gain a 100% seal. These re-treated cracks obviously contained large voids which required additional product to bridge the cracks entirely. It should be noted that the site had been leaking for a period of approximately 9 months prior to the Radcon #7 application. This is the reason for the extensive calcium leaching (staining) on the underside of the slab.

Site Notes:

Radcon #7 is a registered Radcrete Pacific Pty Ltd trademark of Radcrete Pacific Pty Ltd A.C.N. 003 228 975 Page 3 of 3 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 28-31 - Site Ref - Car Parks & Trafficable.doc

SITE REFERENCE
Water Retaining Structures
ENTACT CLOUGH WATER TANK, INDONESIA Location: Specification: Main Contractor: Applicators: Area Treated: Description: Indonesia PT Petrosea Entact Clough PT Argacipta Cemerlang 1200 Sqm Water tank Specification: Main Contractor: Applicator: Area Treated: Completed: Description: Veidekke AS Radcon Scandinavia AS / Minihaller AS 900 sqm 2 Year old pools with failed membrane and leaking cracks in structural concrete. Took 5 days to finally seal after application. Shows slow gel growth. Hydrostatic pressure = 5m

WATER TANKS, NAURU Location: Specification: Engineers: Applicator: Area Treated: Description: Island of Nauru Nauru Phosphate Corporation Nauru Phosphate Corporation Nauru Phosphate Corporation 2000 Sqm Waterproofing and chloride resistance to salt water holding tanks. New walls and floor formed on the inside of existing, chloride contaminated tanks.

FOUNTAIN PLAZA DE CASTILLA, SPAIN Location: Specification: Main Contractor: Applicator: Area Treated: Completed: Description: Madrid, Spain Madrid City Council F.C.C. Troway Srl 2000 Sqm March 1995 Large fountain in the Plaza de Castilla over freeway tunnel.

VAUCLUSE WATER TOWER Location: Specification: Applicator: Area Treated: Completed: Description: Vaucluse, Sydney Australian Construction Services Pty Ltd BMP Group Pty Ltd 2300 Sqm March 1992 Water tank refurbishment. Tank exposed to High chloride environment. Waterproofing and Chloride protection required.

AMPANG HILIR CONDOMINIUMS, MALAYSIA Location: Engineer: Main Contractor: Area Treated: Description: Kuala Lumpur, Malaysia Taylor Woodrow - Teamwork Corp. I&P Fletcher Constructions 3000 Sqm Suspended Pools and podium deck above a car parking area.

STAMFORD RESORT Location: Specification: Main Contractor: Area Treated: Completed: Description: North Ryde, Sydney Dainfords Pty Ltd Dainfords Pty Ltd 2000 Sqm November 1988 Suspended lake with fish over car-park.

CURRAGH COAL MINE, QUEENSLAND Location: Client: Engineers: Applicator: Area Treated: Completed: Description: Blackwater, Queensland Curragh Coal CMPS&F Concrete Cutting and Sealing 6500 Sqm June 1995 Waterproofing of large tailings tank.

TAIWAN ROOFTOP SWIMMING POOL II Location: Applicator: Area Treated: Description: Taipei, Taiwan Kingal Trading 300 Sqm Suspended swimming pool over apartments

TEMPE WATER TOWER Location: Specification: Treatment: Area Treated: Completed: Description: Tempe, Sydney Australian Construction Services Andersal Engineering 852 Sqm May 1991 Failed tanking membrane on the inside of water tank removed and treated to waterproof existing leaking cracks.

JAKARTA SWIMMING POOL Location: Applicator: Area Treated: Description: Jakarta, Indonesia PT Argarcipta Cemerlang 400 Sqm. Failed tanking membrane. Leaking pool, treatment to mortar joints between tiles. This work Non-guaranteeable work However is very cost effective compared to removing tiles. 100% successful in this instance.

BAAN CHAOPRAYA CONOMINIUMS, THAILAND Location: Client: Applicator: Area Treated: Description: Bangkok, Thailand Sole/Somprasong Group Project Radcon Thailand 3000Sqm Total 2 Suspended swimming pools, Rooftops and Podium deck. Pool had honeycombed sections which were hacked out, RF#7 treated and repatched. This was allowed to cure for 7 days Then RF#7 applied to total area.

BJERTNESSJOEN DAM, NORWAY Location: Owner: Area Treated: Applicator: Size: Description: Norway Nannestad Kommune Drinking water dam Minihaller AS 700 sqm Old dam with leaking cracks that were treated Radcon #7, plus a Calcium solution to supplement the leached Calcium over the
Radcrete Pacific Pty Ltd A.C.N. 003 228 975 04/06/03 All rights reserved

GULLBRING SWIMMING POOL, TELEMARK NORWAY Location: Telemark, Norway

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd Page 1 of 2 C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 32-33 - Site Ref - Water retaining.doc

years. There was also an issue of freeze thaw near the surface of the water where cracks were being made worse by the ice. LANGSUANVILLE CONDOMINIUMS, BANGKOK Location: Specification: Engineer: Main Contractor: Applicators: Area Treated: Description: Bangkok, Thailand Projects Asia Meinhardt Engineers Philip Holzman Radcon Thailand 1200 Sqm Pool & deck

JAYA BANK FOUNTAIN, JAKARTA Location: Specification: Main Contractor: Applicators: Area Treated: Jakarta, Indonesia Arkonin Jaya Konstruki PT Argacipta Cemerlang Fountain

DOVER PARKVIEW CONDOMINIUMS, SINGAPORE Location: Specification: Main Contractor: Applicators: Area Treated: Description: Singapore Andrew Tan Architects Neo Corporation Reverton Engineering 3,500 sqm 3 swimming pools in podium deck This swimming pool has underwater music.

SEGA WORLD/DARLING WALK, SYDNEY Location: Main Contractor: Applicators: Area Treated: Description: Size: Darling Harbour, Sydney, Australia John Holland Construction Kratrim Pty Ltd. Lake One meter deep lake 4,000 sqm

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd Page 2 of 2 C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 32-33 - Site Ref - Water retaining.doc

Radcrete Pacific Pty Ltd A.C.N. 003 228 975 04/06/03 All rights reserved

SITE REFERENCE
Bridge Applications
NEW TAIPEI RAISED FREEWAY, TAIWAN Location: Client: Engineers: Applicator: Application: Date of Application: Size: Wuku to Sitchu, Taipei, Taiwan Ministry of Transportation T.Y. Lin Engineers Kingal Trading Co. Dual raised concrete freeway, topped with asphalt March 1995 65,000 square metres Client: Consultant: Main Contractor: Applicator: Date of Application: Application: Size: Hong Kong Govt. Department of Highways, Hong Kong Hop Tai Wong Fu & Co. October 1989 Roadway overpass exposed 10,000 sqm

PERTH BRIDGE, AUSTRALIA Location: Client: Date of Application: Application: Size: Tasmania, Australia Department of Main Roads December 1990 Department of Construction 2,600 sqm

HOLENDALEN RAILWAY BRIDGE, NORWAY Location: Main Contractor: Client: Consulting Engineer: Application: Date of Application: Concrete: Size: Holendalen, Norway Skanska & Ragnar Evensen AS NSB (Norwegian State Railway and Road Authority) John Holt AS Radcon Scandinavia / Minihaller AS September 1995 9000m3 C70/C55MA 6000 Sqm Bridge Deck and Edge Beam

K11A HONG KONG FLY OVER Location: Client: Consultant: Main Contractor: Date of Application: Application: Applicator: Size: Hong Kong Hong Kong Govt. Hong Kong Highway Department Chiu Hing Construction & Transportation Co. Ltd. April 1997 Old concrete fly overs Wong Fu & Co. 15,200 sqm

GJOVIK RAILWAY BRIDGE, NORWAY Location: Main Contractor: Client: Consulting Engineer: Application: Date of Application: Concrete: Size: Gjovik, Norway Selmer AS NSB (Norwegian State Railway and Road Authority) John Holt AS Radcon Scandinavia / Minihaller AS October 1995 C70/C55MA 600 sqm Bridge deck and edge beam.

K11B HONG KONG FLY OVER, Location: Client: Consultant: Date of Application: Application: Applicator: Size: Hong Kong Hong Kong Govt. Hong Kong Highway Department April 1997 Old concrete fly overs Wong Fu & Co. 4,000 sqm

MEKONG RIVER (FRIENDSHIP) BRIDGE, THAILAND/LAOS Location: Funded by: Engineers: Main Contractor: Applicator: Date of Application: Application: Size: Mekong River on border of Thailand & Laos Australian Government Sinclair Knight Merz & Maunsell John Holland Construction John Holland Construction January 1993 Bridge deck surface on mid span cast in situ pieces covered with asphalt. 2,000 sqm

MOTORWAY ENTRANCE RAMP, HOMEBUSH, SYDNEY Location: Client: Date of Application: Application: Applicator: Size: James Ruse Drive, Sydney F4 Motorway entrance ramp Roads & Traffic Authority, NSW October 1996 Exposed concrete after acid spill Kratrim Pty. Ltd. 1,600 sqm

BRIDGE DECK, TAIWAN LIGHT RAIL TRANSPORT STATION, KUALA LUMPUR Location: Consultant: Applicator: Date of Application: Application: Size: Road to Great Taipei ~ New Town, Taiwan Continental Engineering Corporation Kingal Trading Co. January 1990 Bridge deck left exposed 3,000 sqm Location: Client: Engineer: Contractor: Date of Application: Application: Applicator: Size: Commonwealth Station, Kuala Lumpur Malaysian Government Taylor Woodrow Teamwork June 1997 Station deck & rooftops Brunseal (M) Sdn. Bhd. 2,000 sqm 14 stations in total treated with Radcon #7

NEW BURNETT RIVER BRIDGE, AUSTRALIA Bundaberg, Queensland Queensland Transport McConnell Dowell Concrete Cutting & Sealing March 1995 Bridge deck prior to asphalt topping 2,000 sqm K37 - HONG KONG FLY OVER, HONG KONG Location: Gascoigne Road, Hong Kong

LIGHT RAIL TRANSPORT STATION, KUALA LUMPUR Location: Client: Engineer: Contractor: Kuala Lumpur Malaysian Government Taylor Woodrow Teamwork
Radcrete Pacific Pty Ltd A.C.N. 003 228 975 04/06/03 All rights reserved

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd Page 1 of 2 C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 34-35 - Site Ref - Bridges.doc

Date of Application: Application: Applicator: Size:

June 1997 Station deck & rooftops Brunseal (M) Sdn. Bhd. 2,000 sqm 14 stations in total treated with Radcon #7

LIGHT RAIL TRANSPORT STATION, KUALA LUMPUR Location: Client: Engineer: Contractor: Date of Application: Application: Applicator: Size: Kuala Lumpur Malaysian Government Taylor Woodrow Teamwork June 1997 Station deck & rooftops Brunseal (M) Sdn. Bhd. 2,000 sqm 14 stations in total treated with Radcon #7

BREMSA BRIDGE, NORWAY Location: Client: Engineer: Contractor: Application: Areas Treated: Size: Norway Jernbaneverket Utbygging (Norwegian State Railway) Arild Berg AS PEAB Betongforsegling AS (Radcon Scandinavia AS) Bridge Deck, edge beams. 5,300 square metres

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd Page 2 of 2 C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 34-35 - Site Ref - Bridges.doc

Radcrete Pacific Pty Ltd A.C.N. 003 228 975 04/06/03 All rights reserved

SITE REFERENCE
Rooftop Applications
LIPPO SUPERMALL, TANGERANG, INDONESIA Location: Client: Engineers: Architects: Main Contractor: Applicator: Application: Size: Jakarta, Indonesia LippoLand Development PT Davy Sukamata & Partners The Jerde Partnership, USA PT Tatamulia Nusantara Indah PT Argacipta Cemerlang Rooftop, car park & sprinkler tank. 46,000 square metres DULWICH INTERNATIONAL COLLEGE, THAILAND Location: Architect: Engineer: Main Contractor: Applicator: Application: Size: Phuket, Thailand RMJM Arunchaiseri B+B - Kin Sun Radcon Thailand Concrete gutters 3,500 sqm

KEIO UNIVERSITY, JAPAN TUK CHARNG (ELEPHANT), BANGKOK Location: Engineer: Architect: Application: Size: Bangkok, Thailand Arun Chaiseri Ongart Architects Rooftop exposed + landscaped garden 5,000 sqm Location; Main Contractor: Applicator: Application: Size: Tokyo, Japan Obayashi Contractors Radcon Japan Rooftop 2,500 sqm

AUSTRALIAN TAXATION OFFICE, AUSTRALIA KL TELECOMMUNICATIONS TOWER, MALAYSIA Location: Main Contractor: Application: Size: Kuala Lumper, Malaysia rd 3 Largest Telecommunications Tower in the world Wayss & Fretag (Malaysia) Sdn. Bhd. Level 9 & 10 of Tower Head 750 sqm Location: Client: Engineer: Architect: Applicator: Application: Size: Wollongong NSW 2500 Australian Construction Services Acer Wargon Chapman Woodhead Firth Lee Kratrim Pty. Ltd. Rooftop and car park left exposed 3,500 sqm

PALACE OF THE GOLDEN HORSES, KUALA LUMPUR Location: Architect: Engineer Main Contractor: Applicator: Application: Size: Kuala Lumpur, Malaysia Wimerly Allison Tong & Goo Arup Consultants Strategic Alliance Construction Brunseal Rooftops, landscaped podium entrance 20,000 sqm

AUSTRALIAN TAXATION OFFICE, AUSTRALIA Location: Client: Engineer: Architect: Applicator: Application: Size: Hurstville NSW 2220 Australian Construction Services Giles Tribe Architects Taylor Thompson Whiting Kratrim Rooftop left exposed 4,000 sqm

BAAN SANSRAN, HUA HIN, THAILAND Location: Architect: Engineer: Main Contractor: Applicator: Application: Size: Hua Hin, Thailand Palmer & Turner Arunchaiseri Gammon Radcon Thailand Rooftops, wet areas, balconies, landscaping 22,500 sqm

JUNCTION 8, SINGAPORE Location: Main Contractor: Application: Size: Singapore Construction & Development Co. Podium deck tiled over. 5,600 sqm

SENTOSA MEDICAL CENTRE, MALAYSIA Location: Engineer: Contractor: Application: Size: Kuala Lumpur, Malaysia T.Y.Lin (SEA) Engineers Multiplex Engineering Sdn Bhd Rooftop covered with insulation and pavers. 2,500 sqm

ONE PLACE, BANGKOK Location: Architect: Engineer: Main Contractor: Applicator: Application: Size: Bangkok, Thailand Palmer & Turner Thai-Takenaka Radcon Thailand Podium level above retail, pool & rooftop 2,000 sqm

SERENITY GARDENS, HONG KONG Location: Applicator: Application: Size: Hong Kong Wong Fu & Co. Podium deck covered with gardens and tiles 8,000 square metres

ALL SEASONS PLACE, BANGKOK Location: Architect: Engineer: Main Contractor: Applicator: Application: Size: Bangkok, Thailand Palmer & Turner Palmer & Turner Christiani & Nielsen Radcon Thailand Rooftops of 3 towers 5,500 sqm

BAYER AUSTRALIA, PYMBLE

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd Page 1 of 3 C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 36-37 - Site Ref - Rooftops.doc

Radcrete Pacific Pty Ltd A.C.N. 003 228 975 04/06/03 All rights reserved

Location: Main Contractor: Engineer: Applicator: Application: Size:

Pymble NSW 2009 Barclay Mowlem Constructions Pty. Ltd. Ronnie & Bye Pty. Ltd. Kratrim Pty. Ltd. Roof over offices 1,600 sqm

Architect: Main Contractor: Applicator: Application: Size:

Span Group Saltzer Constructions B& P Caelli Rooftop and landscaped podium deck 2,500 Sqm

ALLERGAN OFFICE WAREHOUSE, SYDNEY AWA & ERICSSON TOWERS, SYDNEY Location: Architect:: Main Contractor: Engineer: Applicator: Application: Size: North Ryde NSW 2113 John Bruce Taylor & Assoc. RIC Constructions Pty. Ltd. Taylor Lauder Engineers Pty. Ltd. Kratrim Pty. Ltd. Rooftop & Podium over offices and computer centre. 4,770 sqm Location: Architect: Engineer: Application: Size: Frenchs Forest NSW 2086 Brewer Partnership Taylor Thomson Whitting Car park podium deck 1,500 sqm

CITY VILLA, BANGKOK Location: Architect: Engineer: Applicator: Application: Size: Bangkok, Thailand Raimon Land Fraiser Worley Engineers Radcon Thailand Rooftop 4,000 sqm

DOVER PARK VIEW, SINGAPORE Location: Architect: Main Contractor: Applicator: Application: Size: Singapore Andrew Tan Architects. Neo Corporation Reverton Engineering (S) Pte Ltd Rooftops, wet areas, pool and landscaped podium deck 50,000 sqm

MOLEX FACTORY, SINGAPORE Location: Architect: Engineer: M&E Engineer: Main Contractor: Applicator: Application: Size: Singapore Design International De Consultants Lincolne Scott Mei Hwa Construction Works Reverton Engineering Rooftop over factory 3,000 sqm

GRANDE ESPLANADE, SYDNEY Location: Architect:: Main Contractor: Engineer: Applicator: Application: Size: Manly Cove NSW 2095 Michael Dysart & Partners. Concrete Constructions Pty Ltd Ashby Doble Pty Ltd Multitech Pty Ltd Rooftop & swimming pool 2,500 sqm

WAVE PLACE, BANGKOK Location: Architect: Engineer: Main contractor: Project Managers: Applicator: Application: Size: Bangkok, Thailand Palmer & Turner Meinhardt Engineers Thai Takenaka International Ltd. Projects Asia Ltd. Radcon Thailand Co. Ltd. Level 2 car park over offices & Level 2 exposed podium areas Size: 2,000 sqm

HMAS WATERHEN, SYDNEY Location: Architect:: Main Contractor: Engineer: Client:: Application: Size: Waverton NSW Australia Peddle Thorpe Architects. Philip Lipman Pty Ltd Sinclair Knight Merz Pty Ltd Australian Construction Sevices Rooftop & Carpark 8,800 Sqm

CHIJMES, SINGAPORE Location: Architect: Engineer: Main contractor: Main contractor: Applicator: Application: Size: Singapore Ong & Ong Architects Ove Arup & Partners Low Keng Huat (Singapore) Gammon Contractors Reverton Engineering Walkway rooftops & landscaped podium over car park 3,000 sqm

BAAN CHAOPRAYA CONDOMINIUMS, BANGKOK Location: Client: Applicator: Application: Size: Bangkok, Thailand Sole/Somprasong Group Project Radcon Thailand Rooftop , Swimming Pools and Podium Deck 3,000 Sqm

SCEGGS DARLINGHURST, SYDNEY Location: Architect:: Main Contractor: Engineer: Client:: Application: Size: Darlinghurst NSW 2010 Devine Erby Mazlin Gledhill Constructions Pty. Ltd. Tierney & Partners Pty. Ltd. SCEGGS Girls School Sportsfield above gymnasium 1,600 sqm

HONDA SHOWROOM, BANGKOK, THAILAND Location: Architect: Main Contractor: Applicator: Application: Size: Bangkok, Thailand Vortech Thai-Daiho Radcon Thailand Rooftops, car park & tank 2,600 sqm

DUTY FREE SHOPPING STORE, SAIPAN Location: Main Contractor: Applicator: Application: Size: Saipan, Micronesia Fletcher Pacific JT Developments Rooftop exposed 3,600 sqm ASTON MANSION, SINGAPORE

400 LONSDALE STREET, MELBOURNE Location: Melbourne VIC 3000


Radcrete Pacific Pty Ltd A.C.N. 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 36-37 - Site Ref - Rooftops.doc

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd Page 2 of 3

Location: Client: Architects: Engineers: Application: Areas Treated: Size:

Singapore Far East Organisation RDC Architects TAN EE PING Reverton Engineering Rooftops, wet areas, entrance podium, planters, swimming pool 20,000 sqm

Main Contractor: Application: Areas Treated: Size: Applied:

Baulderstone Hornibrook Kratrim Pty Ltd. Rooftop & Plant room 1,500 sqm July 1997

CENTRAL PLAZA RACHADA-RAMA III, THAILAND Location: Client: Architects: Engineers: Main Contractor: Application: Areas Treated: Size: Thailand Num-Sap Pattana Co. Ltd Plan Architects/RTKL Associates Inc. (USA) Arun Chaiseri Consulting Engineers Co. Ltd Philipp Holtzman (Thai) Ltd. Radcon Thailand Co. Ltd Roof, Food Court, Water Features 12,500 sqm.

BANGKOK CITY TOWER Location: Client: Architects: Engineers: Main Contractor: Application: Areas Treated: Size: Bangkok City CBD City Reality Co. Ltd Inter Architect Co. Ltd 2-R Engineering Co. Ltd Thai Kajima Co. Ltd Radcon Thailand Roof decks, podiums, driveways, water tanks, helipad. 5,000 Sqm.

CENTRAL RAILWAY CANOPIES, SYDNEY Location: Client: Architects: Engineers: Main Contractor: Application: Areas Treated: Size: Sydney State Rail Authority Woolacott Consulting Engineers BMP Group Kratrim Pty Ltd Concrete Canopies 8,000 sqm.

EUNOS TECHPARK, SINGAPORE Location: Client: Architects: Engineers: Main Contractor: Application: Areas Treated: Size: Singapore Far East Organisation TAA Architects KTP Consultants Mitsui Construction Reverton Engineering Rooftops and wet areas 15,000 sqm.

GARDEN CITY COMMUNITIES, USA Location: Client: Agent: Application: Areas Treated: Size: San Diego, USA Garden City Communities Inc. Surface Technologies In-house Podium Decks 10,000 sqm

SHOPPING CURITIBA, BRAZIL Location: Builder: Application: Areas Treated: Size: Parana, Brazil Irmaud Constructora, SA Lienge Netherland Rooftop 3,000 sqm

MERCANTILE MUTUAL CENTRE, KENT ST, SYDNEY Location: Architects: Engineers: Kent St, Sydney, Australia Kann Finch Architects Sinclair Knight Mertz
Radcrete Pacific Pty Ltd A.C.N. 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 36-37 - Site Ref - Rooftops.doc

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd Page 3 of 3

SITE REFERENCE
Miscellaneous
GURKHA CONTINGENT QUARTERS, SINGAPORE Location: Client:: Main Contractor: Applicator: Size: Description: Singapore Public Works Department So Say Cheong Pte Ltd Reverton Engineering (S) Pte Ltd 12,000 Square Metres Wet Areas & Sprinkler Tanks

KEPPEL DISTRIPARK WAREHOUSE, SINGAPORE Location: Client: Applicator: Size: Description: Singapore Port Of Singapore Authority Reverton Engineering (S) Pte Ltd 2,000 Sqm Concrete Gutter Around Warehouse

MONUMENT YOGYA KEMBALI, INDONESIA Location: Client: Application: Size: Description: Yogyakarta, Indonesia Department Pekerjaan Umumwho Pt Argacipta Cemerlang 2,600 Sqm Application To Structural Concrete Covered With Tiles After Treatment.

MLC HOCKEY FIELD, SYDNEY Location: Client: Architects: Engineers: Main Contractor: Application: Description: Size: Burwood Nsw 2134 Mlc Girls School Bowden Design Partnership Pty. Ltd. Robert Lee Architects Woolacott Engineers Pty Ltd Austruc Pty. Ltd. Kratrim Pty. Ltd. Suspended Hockey Field Over Car-Park 6,000 Sqm

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd Page 1 of 1 C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 38 - Site Ref - Miscellaneous.doc

Radcrete Pacific Pty Ltd A.C.N. 003 228 975 04/06/03 All rights reserved

Safety:
Material Safety Data Sheet
Section 1
Use: Product Name: Other Names: Product Code: Manufacturer/Distributor:

Identification
Concrete Waterproofing and Protection Radcon Formula #7 UN Number: N/A Hazchem Code: N/A Dangerous Goods Class: Radcrete Pacific Pty Ltd Poison Schedule: Level 3, 45A Bay Street Pages: Double Bay NSW 2028 Date of Issue: AUSTRALIA Telephone: Jason Klaas Fax: Emergency: N/A N/A N/A N/A 2 22/4/97 +61 (0)2 9362 3511 +61 (0)2 9362 3244 +61 (0)414 360 753

Preparer:

Section 2
Component Sodium Silicates Proprietary Biochemicals Surfactants CAS No. N/K N/K N/K

Composition
% (by weight) Proprietary Proprietary Proprietary OSHA PEL N/K N/K N/K ACGIH N/K N/K N/K Other Limits N/K N/K N/K

Section 3
Appearance: Odour: Boiling Point: Vapour Pressure: Colourless liquid Low Odour Slightly chlorine o 101 Celsius N/A water based

Physical Data
Vapour Density: Solids Content: Specific Gravity: Solubility in Water: pH: N/A 27.7% 1.225 Complete 11.7

Section 4
Flash Point: Flammability Limits: Auto Ignition Temperature: Extinguishing Media: Special Fire Fighting Procedures: Unusual Fire & Explosion Hazards:

Fire & Explosion Data


Non-combustible N/A N/A N/A N/A N/A

Section 5
Stability: Incompatibility: Hazardous Polymerisation: Hazardous Decomposition Products:

Reactivity Data
Stable Gels when mixed with acid Will not occur N/A

Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd. Page 1 of 2

Radcrete Pacific Pty Ltd 2000 ACN 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 47-48 - Material Safety Data Sheet.doc

Section 6
Eye Contact: Skin Contact: Inhalation: Ingestion: Chronic Hazard: Signs and symptoms of exposure: Medical conditions aggravated by exposure: First Aid Procedures: Inhalation: Eyes: Skin: Ingestion: Advice for Doctor:

Health Hazard Data


Causes eye irritation Can cause skin irritation Can cause irritation to respiratory tract Can cause irritation to oesophegus & stomach No known chronic hazards. Not listed by OSHA, NTP or IARC as a carcinogen Sneezing, burning in nose and throat (prolonged inhalation), pain redness and tearing (eye exposure) itching or burning (prolonged skin exposure) Pre-existing skin & respiratory ailments Remove to fresh air Flush eyes with water for at least 20 minutes Wash skin with soap and water, remove and wash contaminated clothing Dilute by drinking large amounts of water or milk allowing vomiting to occur. Do not induce vomiting. Seek medical advice Treat as for alkaline material

Section 7
Spills/Leaks: Handling and use: Storage & Transport:

Precautions for Safe Handling and Use


Take up spills with sand, soil or other absorbent materials and place in sealed containers for disposal. Contaminated area can be washed clean with warm detergent solution. Keep spills and cleaning run off out of municipal sewers and open bodies of water. Wash after handling and before eating, drinking, smoking. Keep in sealed containers No special precautions required

Section 8
Respiratory Protection: Skin: Eyes: Ventilation: Other Protection: N/A = Not Applicable N/K = Not Known

Control Measures
Where spraying use a filter face mask In enclosed areas use a cartridge type respirator NIOSH approved Avoid contact wear suitable protective clothing use rubber gloves Avoid contact use chemical goggles Provide adequate ventilation Safety shower and eyewash fountain should be within direct access

Signature of Preparer Please ensure all persons coming into contact with this product are aware of the information contained n the MSDS. Information presented herein has been compiled from sources considered to be reliable to the best of our knowledge and belief but is not guaranteed to be so. It is the users responsibility to determine for them the suitability of any material for a specific use and to adapt safety precautions as may be necessary. If you need further information from us to make the determination that you must make to use this material safely, please contact the above named preparer.

FURTHER INFORMATION

Radcrete Pacific Pty Ltd Level 3, 45a Bay Street Double Bay NSW 2028 AUSTRALIA Ph: +61 2 9362 3511 Fax: +61 2 9362 3244
ACN: 003 228 975
Radcon Formula #7 is a registered trademark of Radcrete Pacific Pty Ltd. Page 2 of 2 Radcrete Pacific Pty Ltd 2000 ACN 003 228 975 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radcon\Page 47-48 - Material Safety Data Sheet.doc

Datasheet:
PRODUCT NAME RadmyxTM Capillary Waterproofing System MANUFACTURER Radcrete Developments Pty Ltd Level 3, 45a Bay Street Double Bay NSW 2028 SYDNEY AUSTRALIA e-mail: sales@radcrete.com.au web: www.radcrete.com.au Ph: +61-2-9362 3511 Fax: +61-2-9362 3244 ACN: 069 156 234 DESCRIPTION RadmyxTM Capillary Waterproofing System is a complete system to waterproof below grade applications such as basements and water holding structures. Through the process of osmosis the active chemicals in RadmyxTM react with the hydration products of cement to create a continuous barrier of insoluble crystals deep within the capillary structure of the concrete. These crystals block the passage of water whilst permitting the transmission of air and water vapour, enabling the structure to breathe. RadmyxTM is equally effective against positive or negative water pressure and can be used as an admixture or surface applied as a slurry on the internal or external surface. Full waterproofing is normally achieved 5 7 days after application. After the crystallisation process has successfully waterproofed the structure the active chemicals in RadmyxTM remain dormant in the concrete. Any later contact with water will reactivate the sealing process. Admixture APPLICATIONS In-situ Concrete Basements Lift Pits Core-filled Blockwork Canals Tunnels Reservoirs Dams

KEY BENEFITS Long-term performance - No re-application or future maintenance require Fast Backfilling - Backfilling operations can undertaken immediately after forms are stripped be

No Protection Required - Protection boards and drainage cells can be eliminated because there is no risk of damage during construction or thereafter. Fault Finding - If shrinkage cracks develop - easy to find and repair using RadmyxTM Slurry & Mortar No lifting of membranes required. Efficient - Compresses construction timetable since waterproofing can be either done from positive or negative side MAINTENANCE None required. GUARANTEES 10 year guarantees for RadmyxTM treated areas are available where approved applicators are used and in appropriate situations. Contact the manufacturer for further information and confirmation of suitability. LIMITATIONS RadmyxTM is not suitable for waterproofing above ground applications or applications exposed to thermal stress. Use Radcon Formula #7 for Above ground applications RadmyxTM is not suitable for waterproofing dynamic cracks or movement joints. Use elastomeric joint sealant for these applications. PACKAGING 12.5 kg bags or pails SHELF LIFE & STORAGE 12 months Keep container sealed SPECIFICATIONS e-mail us at: sales@radcrete.com.au

RadmyxTM Admixture Is a cementitious powder added to dry mix at the batch plant at a rate of 1.5% of binder ie Cement +Fly Ash.

Surface Applied RadmyxTM Slurry Supplied as a powder and mixed with water, RadmyxTM Slurry is applied directly to positive or negative side of concrete, blockwork or cement renders in areas where general waterproofing is required

RadmyxTM Mortar Mixed to a mortar consistency with water, RadmyxTM Mortar is used for crack & honeycomb repair as well as a screed, render and fillet material. RadmyxTM Hardener Used in place of water with RadmyxTM Slurry to obtain ultra rapid set properties essential for leak plugging

INSTRUCTIONS
TM Radmyx is a trademark Radcrete Developments Pty Ltd 2001 of Radcrete Developments Pty Ltd. ACN 069 156 234 Specification details may change without notice. 04/06/03All rights reserved Page 1 of 2 C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 70-71 - Radmyx Datasheet.doc

Cold Joints (New) Admixture RadmyxTM Admixture


Addition: 1.5% of the binder content by weight. ie. Cement+Flyash RadmyxTM Admixture should be distributed evenly through the dry mix prior to adding water. The joint should be formed by a vertical stop board during construction. Use a bentonite waterstops such as Volclay RX and RadmyxTM Slurry as a dry shake on the joint face prior to pouring the subsequent concrete.

Cold Joints (Existing)


Where the joint leaks repair similar to crack or void/ honeycomb.

Surface Applied RadmyxTM Slurry


Mixing: 1 water : 2.25 - 2.5 powder by volume. Rate: 0.8 kg per m2 per coat. Technique: 1. Dampen surface prior to application. 2. Applied by brush or spray onto the dampened substrate. 3. Apply 2 coats at right angles, the 2nd coat whilst the first is firm, but 'green' - usually 3-4 hours after first coat (dependant on temperature). 4. If 2nd coat is done the following day dampen with water before applying the second coat.

Penetrations (New)
Use bentonite waterstops as a wrap around the penetration during construction.

Movement Joints
Responsibility of others.

Cracks
Identify static cracks over 0.4 mm that must be chased out and repaired. 1. Chase out to a depth of minimum 30 - 40mm 2. Dampen with water 3. Prime with RadmyxTM Slurry 4. Laminate maximum 30mm layers with RadmyxTM Mortar until the crack is filled

RadmyxTM Mortar Mixing: Mix sufficient water to achieve a mortar consistency Rate: Use as requires. Technique: 1. Dampen Surface prior to application. 2. Laminate in layers no more than 30mm thick.

General Instructions (Surface Application)


Add water to RadmyxTM NOT RadmyxTM to water. Only mix sufficient RadmyxTM that can be used in 20 minutes. Protect RadmyxTM from sun & ponding water for 4 days. RadmyxTM should be sprayed with a fine mist of water 34 times a day for 4 days to assist curing & penetration. Clean tools and equipment immediately after use. Use of plastic or rubber containers is recommended. RadmyxTM waterproofing is not suitable for subsequent decoration unless first protected by sand/cement render. Surfaces must be free from dust, oil, grease, paint, residual curing compound, form release oil or any previous surface treatment that will impair adhesion of the RadmyxTM . Remove any laitance and provide a slightly rough, open pored surface sufficient to act as a mechanical key. This is essential for adequate adhesion of the RadmyxTM.

Voids & Honeycombing


1. 2. 3. 4. Hack out until solid concrete is found Dampen with water Prime the area with RadmyxTM Slurry Laminate RadmyxTM Mortar in 30mm (maximum) layers until the void is filled

Plugging Leaks
Leaks and holes drilled to relieve water pressure are sealed permanently using a plugging compound of RadmyxTM Slurry mixed with RadmyxTM Hardener To plug leaks under pressure: 1. Chase out the area of the leak until water flow is free and insert a length of plastic hose. 2. Seal the plastic hose with plugging compound as above. 3. Clean the cavity and apply a coat of RadmyxTM Slurry and when tacky, fill the cavity with a RadmyxTM Mortar and allow to cure. 4. When surrounding waterproofing is complete, withdraw the hose and plug the hole with plugging compound using a gloved thumb to hold it in place until set (approximately 1 minute). 5. Fill the remainder of the hole with RadmyxTM Mortar When the mortar has set, complete the waterproofing, lapping slurry coats onto the concrete surrounding the hole. Holes under low pressure can be similarly sealed, but pipe insertion and removal is omitted.

Surface Preparation (Surface Application)

Note: The information presented is intended guide only and is correct to the best of our knowledge at the time of publication. It should not be considered as a definitive approval for suitability for a particular purpose. Please contact the manufacturer, distributor or approved applicator for confirmation of suitability. Ancillary detailing recommendations are provided in good faith to assist in achieving final waterproof result; we accept no liability for those recommendations or those products performance in use, refer to product supplier.

TM Radmyx is a trademark Radcrete Developments Pty Ltd 2001 of Radcrete Developments Pty Ltd. ACN 069 156 234 Specification details may change without notice. 04/06/03All rights reserved Page 2 of 2 C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 70-71 - Radmyx Datasheet.doc

Instructions to Specifier. Append the following Specifications and Drawings to tender and contract specifications.

TM

Radmyx is a trademark Radcrete Developments Pty Ltd Of Radcrete Developments Pty Ltd. A.C.N. 069 156 234 Page 1 of 4 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 72-76 - Instructions to Specifier.doc

Waterproofing Admixture
1 1.1 GENERAL SCOPE This specification describes a waterproofing system for below grade concrete structures such as lift pits, basement floors and walls, water holding structures, tunnels and thermally insulated decks such as podium decks Proprietary item: Radmyx Capillary Waterproofing System Supplier: Radcrete Developments Pty Ltd. 1.2 RELATED DOCUMENTS Refer drawings, Preliminaries, Bill of Quantities, General Requirements, and general provisions of the contract. RELATED WORKS SPECIFIED ELSEWHERE Reinforcement, concrete installation , curing, joint preparation and detailing affect this section and are included within this specification. REFERENCES CSIRO test procedures 1. Permeability QUALITY SUBMISSIONS Approval before application Submit a detailed statement describing the concrete waterproofing system to be applied. Inclusions Include literature, details, samples, warranties and the like in the submission as required. Provide the manufacturers or nominated agent/distributors written acceptance and approval of the intended system required. 2.2 QUALITY ASSURANCE Approved applicators Use applicators approved and licensed by the manufacturer or their nominated agent/distributor. Site inspection The approved applicator must inspect the site prior to commencement of application of the system, for purposes of reviewing related conditions affecting the performance requirements of this specification. Safety The site foreman/supervisor shall sight and understand the site specifications and product datasheets. All products described in this section must be used with adequate personal protection as recommended by the Material Safety Datasheet that accompanies each product shipment.

1.3

1.4

2 2.1

TM

Radmyx is a trademark Radcrete Developments Pty Ltd Of Radcrete Developments Pty Ltd. A.C.N. 069 156 234 Page 2 of 4 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 72-76 - Instructions to Specifier.doc

3 3.1

MATERIALS AND COMPONENTS MATERIAL Waterproofing system Provide a complete waterproofing system by cementitious capillary admixture (dosed at 1.5% of binder content) and slurry/mortar repair materials. Through the process of osmosis the admixture, slurry & mortar repair materials form fine, non-soluble fibre like crystals in small cracks, pore and capillary system. Combined with the required detailing of joints, penetration, cracks & honeycombs the system prevents water from entering the structure. REINFORCEMENT, CURING & RELATED DETAILING REINFORCEMENT Shall be in accordance with the current Australian Standards and shall be not less than 1% content. That is no less than 0.25% in each direction on the internal and external face. This equates to moderate/strong degree of crack control. CONCRETE INSTALLATION Insitu concrete Ensure that the concrete is properly compacted by vibration to avoid honeycombing & segregation. CURING Use a curing compound complying with AS3799 that have water retention levels in excess of 90%. CONSTRUCTION/POUR JOINTS Construction joints/pour joints Provide a vertical stop board at all construction/pour joints. Trowel down zone where waterstop is to be applied so is smooth and flat. Areas either side of waterstop area is to be roughened to expose aggregate to facilitate an adequate key for the following pour. Waterstops Install Volclay Waterstop RX as per manufacturers recommendations to prepared area. Apply with the manufacturers Approved Applicator (refer to Floor to Wall & Slab Cold Joint detail following) Broadcast Radmyx as a dry shake to the joint face wall at a rate of 1kg / m2 prior to following pour.

4 4.1

4.2

4.3 4.4

4.5

DRAINS & PENETRATIONS Prior to concrete pour Install Volclay Waterstop RX as per manufacturers recommendations around penetrations. (refer to Penetration Detail following) EXECUTION APPLICATION AND SUPERVISION General Install the system in accordance to manufacturers' published recommendations. Personnel Employ trained applicators. Tools and equipment Use proper tools and equipment and working under the direct supervision of a technically competent and experienced supervisor.

5 5.1

TM

Radmyx is a trademark Radcrete Developments Pty Ltd Of Radcrete Developments Pty Ltd. A.C.N. 069 156 234 Page 3 of 4 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 72-76 - Instructions to Specifier.doc

5.2

BATCHING & MIXING Dosage The admixture is to be dosed at 1.5% of binder content. (Ordinary Portland Cement (OPC) & Flyash/Slag content) Mixing The admixture is to be added to aggregate in the truck and then thoroughly mixed prior to adding sand, water and cement. Water/Binder Ratio This is not to exceed 0.5. Cracks All Stable Leaking Cracks & Cracks exceeding 0.4mm General Mix Radmyx Slurry & Mortar as instructed in Radmyx Datasheet. (See Crack Repair Detail following) Execution Chase out to minimum 30 - 40mm depth. Dampen with water Prime with Radmyx Slurry Laminate Radmyx Mortar in maximum 30mm layers until crack is filled All Moving/Unstable Leaking Cracks Utilise flexible Polyurethane injection system.

5.3

HONEYCOMBS / SEGGREGATION General Mix Radmyx Slurry & Mortar as instructed in Radmyx Datasheet. (See Honeycomb repair detail following) Execution Hack out until solid concrete is found Dampen with water Prime with Radmyx Slurry Laminate Radmyx Mortar in 30mm (maximum) layers until crack is filled

5.4

FORM TIES General Plug with Radmyx Plugging Compound

6 6.1

QUALITY CHECK AND COMMISSIONING QA Documentation All QA procedures to be carried out and signed off. All anomalies to specifications are to be noted. The Batch Check is to be undertaken and signed off. A final inspection is to be made prior to practical completion and signed off prior to a guarantee being issued.

TM

Radmyx is a trademark Radcrete Developments Pty Ltd Of Radcrete Developments Pty Ltd. A.C.N. 069 156 234 Page 4 of 4 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 72-76 - Instructions to Specifier.doc

yyy @@@ ;;; ;;; ;;; yyy @@@ ;;; yyy @@@ ;;; yyyyyy ;;;;;; ;;; ;;; yyy @@@ ;;; yyy @@@ ;;;
Design Detailing:
Slab Cold Joint (Admixture)
Instructions: 1) 2) 3) 4) 5) 6) Use Stop board to finish Pour. Trowel down area where waterstop is to be applied to smooth & flat. Roughen joint either side to provide an adequate key. Install swelling waterstop to manufactures instructions. Broadcast Radmyx as a dry shake to joint at 1kg/m2. Pour next slab.
TM Radmyx is a trademark of Radcrete Developments Pty. Ltd. Page 1 of 1

Radcrete Developments Pty. Ltd. A.C.N. 069 156 234 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 77 - Detail - Slab Cold Joint (Admixture).doc

y ; ;; y ; ;; y ; y ; ;; ;;;;; yyyyyyy ;;;;;;; y ; ;;;;; yyyyyyy ;;;;;;;


Design Detailing:
Floor to Wall Cold Joint (Admixture)
Instructions: 1) 2) 3) 4) 5) Trowel down area where waterstop is to be applied to smooth & flat. Roughen joint either side to provide an adequate key. Install swelling waterstop to manufactures instructions. Broadcast Radmyx as a dry shake to joint at 1kg/m2. Pour wall.
TM Radmyx is a trademark Radcrete Developments Pty. Ltd. of Radcrete Developments Pty. Ltd. A.C.N. 069 156 234 Page 1 of 1 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 78 - Detail - Floor to Wall Cold Joint (Admixture).doc

yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;;

yy @@ ;; yy @@ ;; yy @@ ;; yy @@ ;;

;; ;; ;; yy @@ ;; ;; yy @@ ;;
Design Detailing:
Penetration (Admixture)
Instructions: 1) 2) Use swelling waterstops around penetration according specification. Pour Concrete with Radmyx Admixture.
TM Radmyx is a trademark of Radcrete Developments Pty. Ltd. Page 1 of 1

yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;;
y ; y ; y ; y ; y ; y ; y ;
Radcrete Developments Pty. Ltd. A.C.N. 069 156 234 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 79 - Detail - Penetration (Admixture).doc

yyy @@@ ;;; yyyy ;;;; yyyyyy ;;;;;; yyyyyy ;;;;;; yyy @@@ ;;; yyy @@@ ;;; yyyyyy ;;;;;; yyyy ;;;; yyy @@@ ;;; yyy @@@ ;;;
Design Detailing:
Floor Repair
Instructions: 1) 2) 3) Dampen Floor Area with water. Apply Radmyx Slurry in 2 coats at O.8kg / Sqm. Pour Topping slab on floor.
TM Radmyx is a trademark of Radcrete Developments Pty. Ltd. Page 1 of 1

Radcrete Developments Pty. Ltd. A.C.N. 069 156 234 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 80 - Detail - Floor Repair.doc

y yyyy ; ;;;; y y ; ; yyyy ;;;; y yyyy ; ;;;; y y ; ; yyyyyyy ;;;;;;; y ; yyyyyyy ;;;;;;;
Design Detailing:
Floor to Wall Cold Joint Repair
Instructions: 1) 2) 3) 4) 5) Dampen Joint Area with water. Create fillet in corner with Radmyx Mortar. When firm Dampen Wall/ Floor with Water. Apply Radmyx Slurry in 2 coats at O.8kg / Sqm. Pour Topping slab on floor.
TM Radmyx is a trademark Radcrete Developments Pty. Ltd. Of Radcrete Developments Pty. Ltd. A.C.N. 069 156 234 Page 1 of 1 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 81- Detail - Floor to Wall Cold Joint Repair.doc

yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;;

yy @@ ;; yy @@ ;; yy @@ ;; yy @@ ;;

yyy ;;;

y ; y ; yy @@ ;;

yy @@ ;;
Instructions: 1) 2) 3) 4)
TM

yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;;
yyyy ;;;; y ; yy ;; yyyy ;;;; y ; yyyy ;;;; y ; yyyy ;;;; y ; yy ;; yyyy ;;;; y ;
Design Detailing:
Crack Repair
Radmyx is a trademark Od Radcrete Developments Pty Ltd Page 1 of 1 C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 82 - Detail - Crack Repair.doc

Chase out to a depth of 30-40mm. Dampen with water. Prime area with Radmyx Slurry. Laminate area with Radmyx Mortar in 30mm layers until the crack is filled.

Radcrete Developments Pty Ltd A.C.N. 069 156 234 04/06/03 All rights reserved

yy ;; yy ;; yy @@ ;;

yy @@ ;;
Instructions: 1) 2) 3) 4)
TM Radmyx is a trademark of Radcrete Developments Pty. Ltd. Page 1 of 1

yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; yy ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;; @@ ;;
yyyy ;;;; yy y ;; ; yyyy ;;;; y ; yyyy ;;;; y ; yyyy ;;;; yy y ;; ; yyyy ;;;; y ;
Design Detailing:
Honeycomb Repair

Hack out until solid concrete is found. Dampen with water. Prime area with Radmyx Slurry. Laminate area with Radmyx Mortar in 30mm layers until the void is filled.

Radcrete Developments Pty. Ltd. A.C.N. 069 156 234 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 83 - Detail - Honeycomb Repair.doc

QA Checklist:
THIS CHECKLIST IS TO BE FILLED & APPROVED PRIOR TO POUR

SITE INFORMATION
Project Name:_______________________________________ Site Address: _______________________________________ ___________________________________________________ ___________________________________________________ Customer: __________________________________________ ___________________________________________________ ___________________________________________________ Date of Practical Completion: ___________________________ Project No: __________ Site Contact: ____________________________ Site Phone: _____________________________

Site Fax:_________________________________

CONCRETE SUPPLIER
Company:___________________________________________ Manager:____________________________________________ Batcher:_____________________________________________ Transporter:__________________________________________ Phone:__________________________________ Fax: ____________________________________

APPLICATOR
Company:____________________________________________ Name:_______________________________________________

REINFORCING
Reinforcing CHECK: ___________________________________% Content

CONCRETE MIX DESIGN


Mix Design Sand Sand Aggregate Aggregate Aggregate Cement Fly Ash Water Design Strength Required Slump Shrinkage Radmyx Type Amount Units kg kg kg kg kg kg kg litres mpa mm m kg

Type C only or slag

TM Radmyx is a trademark Of Radcrete Developments Pty Ltd Page 1 of 2

Radcrete Developments Pty Ltd A.C.N. 069 156 234 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 84-85 - QA checklist.doc

Date

Procedure Batch Plant Brief 1. Radmyx Specification Explained 2. Dosage Rate Explained 3. Mix Sequence Explained Concrete kgs Radmyx kgs

Sign

Area Dosed

Comments

Total Concrete Total Radmyx Detailing Penetrations: Present: Yes / No Cold Joints: Present: Yes / No Placement Concrete Vibrated Concrete Finish Concrete Curing Done Yes / No Repair Holes & Form Ties Qty Shrinkage Cracks Lm Present Major Cracks 0.4mm+ Lm Present Honeycombs Present Injection Required Yes / No
Radcrete Developmets Representative: Print Name: _______________________________________ Approved Applicator: Print Name: _______________________________________ Signature: _________________________________ Date: __________ Signature: _________________________________ Date: __________

Product & Amount

Initial

Comments

Initial Yes/No Type Material:

Comments

Repaired

Initial

Comments

TM Radmyx is a trademark Of Radcrete Developments Pty Ltd Page 2 of 2

Radcrete Developments Pty Ltd A.C.N. 069 156 234 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 84-85 - QA checklist.doc

Batch Check:
Project: Customer: Concrete Supplier: Applicator: Date Time Truck Docket # M
3

Radmyx kg

Radmyx Batch #

On-site Verificiation

Applicator Signature: Date of Practical Completion:

TM Radmyx is a trademark Of Radcrete Developments Pty Ltd Page 1 of 1

Radcrete Developments Pty Ltd A.C.N. 069 156 234 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 86 - Batch Check.doc

Safety:
Material Safety Data Sheet
Section 1
Use: Product Name: Other Names: Product Code: Manufacturer/Distributor:

Identification
Cementitious Capillary Waterproofing System Radmyx UN Number: N/A Hazchem Code: N/A Dangerous Goods Class: Radcrete Developments Pty Ltd Poison Schedule: Level 3, 45A Bay Street Pages: Double Bay NSW 2028 Date of Issue: AUSTRALIA Telephone: Jason Klaas Fax: Emergency: N/A N/A N/A N/A 2 1/12/1999 +61 (0)2 9362 3511 +61 (0)2 9362 3244 +61 (0)414 360 753

Preparer:

Section 2
Component Portland Cement Active Chemicals Mineral Fillers CAS No. CAS 65997-16-2 N/K N/A

Composition
% (by weight) Proprietary Proprietary Proprietary OSHA PEL N/K N/K N/K ACGIH N/K N/K N/K Other Limits N/A N/A N/A

Section 3
Appearance: Odour: Melting Point: Boiling Point: Vapour Pressure: Grey Powder None N/A N/A N/A

Physical Data
Vapour Density: Solids Content: Specific Gravity: Solubility in Water: pH: N/A N/A N/A Immiscible N/A

Section 4
Flash Point: Flammability Limits: Auto Ignition Temperature: Extinguishing Media: Special Fire Fighting Procedures: Unusual Fire & Explosion Hazards:

Fire & Explosion Data


N/A N/A N/A N/A N/A N/A

Section 5
Stability: Incompatibility: Hazardous Polymerisation: Hazardous Decomposition Products:

Reactivity Data
Stable N/A N/A N/A

TM Radmyx is a trademark of Radcrete Developments Pty Ltd Radcrete Developments Pty Ltd of Radcrete Developments Pty Ltd A.C.N. 069 158 234 Specification details may change without notice. 04/06/03 All rights reserved Page 1 of 2 C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 88-89 - Material Safety Data Sheet.doc

Section 6
Eye Contact: Skin Contact: Inhalation: Ingestion: Chronic Hazard: Signs and symptoms of exposure: Medical conditions aggravated by exposure: First Aid Procedures: Inhalation: Eyes: Skin: Ingestion: Advice for Doctor:

Health Hazard Data


Causes eye irritation- R41 & S24/25 Can cause skin irritation- R37/38 & S24/25 Can cause irritation to respiratory tracts- S22 Can cause irritation to oesophegus & stomach No known chronic hazards. Not listed by OSHA, NTP or IARC as a carcinogen Sneezing, burning in nose and throat (prolonged inhalation), pain redness and tearing (eye exposure) itching or burning (prolonged skin exposure) Pre-existing skin & respiratory ailments Remove to fresh air, if symptoms still exist, seek medical advise Flush eyes with water for at least 15 minutes, get medical attention Remove and wash contaminated clothing; Wash skin with soap and plenty of water Seek medical advice, Induce vomiting only on advice of physician; point out the high alkalinity of cement. Point out the high alkalinity of cement

Section 7
Spills/Leaks: Handling and use: Storage & Transport:

Precautions for Safe Handling and Use


Collect dry and recycle where possible, collect into sealable container and dispose according to local regulations for construction materials. Keep Containers tightly closed and dry; Avoid formation of dust; Provide adequate ventilation or air evacuation at workplace. Keep in sealed containers; Keep dry.

Section 8
Respiratory Protection: Skin: Eyes: Ventilation: Other Protection: N/A = Not Applicable N/K = Not Known

Control Measures
Use ori-nasal respirator when working in confined areas Avoid contact where possible wear suitable protective clothing use rubber gloves Avoid contact use chemical goggles Provide adequate ventilation Avoid formation of dust; Do not eat, drink or smoke at workplace; Wash hands before breaks and after finishing work

Signature of Preparer Please ensure all persons coming into contact with this product are aware of the information contained in the MSDS. Information presented herein has been compiled from sources considered to be reliable to the best of our knowledge and belief but is not guaranteed to be so. It is the users responsibility to determine for themselves the suitability of any material for a specific use and to adapt safety precautions as may be necessary. If you need further information from us to make the determination which you must make to use this material safely, please contact the above named preparer.

FURTHER INFORMATION

Radcrete Developments Pty Ltd Level 3, 45a Bay Street Double Bay NSW 2028 AUSTRALIA Ph: +61 2 9362 3511 Fax: +61 2 9362 3244
ACN: 003 228 975
TM Radmyx is a trademark of Radcrete Developments Pty Ltd Radcrete Developments Pty Ltd of Radcrete Developments Pty Ltd A.C.N. 069 158 234 Specification details may change without notice. 04/06/03 All rights reserved Page 2 of 2 C:\My Library RadPac\Binders\Rewards Binder\Radmyx\Page 88-89 - Material Safety Data Sheet.doc

Datasheet:
PRODUCT NAME
Radguard SUPPLIER Radcrete Developments Pty Ltd Level 3, 45a Bay Street Double Bay NSW 2028 SYDNEY ~ AUSTRALIA Ph: (+61-2) 9362 3511 ~ Fax(+61-2) 9362 3244 e-mail: radcon@gpo.com.au web: www.radcrete.com.au ACN: 069 156 234 Repels Water Reduction in reinforcement corrosion & spalling Minimises efflorescence Reduces spalling from freeze/thaw cycling Reduction in thermal conductivity Minimises rate of carbonation

BENEFITS

PERFORMANCE DATA
Reduction in water up take: Reduction in chloride ion (salt ingress): Typical depth of penetration: Tested AS/NZS 4456.10 Salt Attack Cycles: >85% >90% 4 10mm >40

DESCRIPTION
Radguard is the latest in water based alkyl silane liquid used for the protection of exposed mineral building materials. Its low viscosity ensures deep impregnation & bonding to the substrate. Radguard application changes the absorption characteristics and surface energy to repel water while still allowing the structure to breathe. Radguards excellent repellency characteristics minimise the damaging effects of moisture such as efflorescence & penetration of destructive contaminants such as chloride ion (Salt) & atmospheric fall out. Alkyl Silanes are used worldwide by engineers to protect buildings, bridges and wharves and is an excellent primer for Radcote Mineral Silicate Paint

SURFACE PREPARATION
All surfaces should be clean, dry and free from all dust, dirt, algae, grease, oil and any other surface contamination. Curing compounds must be removed by grit blasting

NOTES / LIMITATIONS
Avoid application when rain is expected within 2 hours. Always trial an inconspicuous area first to ensure satisfactory results. Overspray will leave a film residue, remove splashes immediately with water.

AREAS OF USE Concrete, Render & Grouts Stone (Natural & Man-made) Blockwork, Brickwork & Pavers Terracotta Primer for Radcote Mineral Silicate Paint

HEALTH & SAFETY


When handling & applying use protective clothing, chemical resistant gloves and eye goggles. Avoid contact with skin & eyes, rinse immediately with water. Do not inhale vapours. Avoid plants, drains, water & soil. Wash hands thoroughly prior to handling food. - refer to Material Safety Data Sheet (MSDS)

PRODUCT INFORMATION
Colour & Finish Material Coverage Shelf Life Packaging No Change to Original Substrate Alkyl Silane Avg 5 Sqm / Litre Between 2.5 Sqm & 10 Sqm / Litre (depending on porosity) 24 Months 5 Litre, 20 Litre & 200 Litre Drums

APPLICATION
Application Method Coats Spray or Roller 1 Must remain a liquid film for 10 Seconds Horizontal Surfaces - must have a mirror like wet look for 1 minute Vertical Surfaces - a 350mm reflective flow must be visible Remove excess Radguard after 5 minutes Initial Cure 4 hours Complete Cure 3 C to 35 C Water
o o

Technique

Curing @ 25 C & 50% Relative Humidity Application Temperature Range Clean-up

3 days

Note: The information presented is intended guide only and is correct to the best of our knowledge at the time of publication. It should not be considered as a definitive approval for suitability for a particular purpose. Please contact the manufacturer, distributor or approved applicator for confirmation of suitability

Radguard is a trademark of Radcrete Developments Pty Ltd Radcrete Developments Pty Ltd 1997 Specification details may change without notice. ACN 003 228 975 Page 1 of 1 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radguard\Page 90 - Datasheet.doc

Instructions to Specifier. Append the following Specifications and Drawings to tender and contract specifications.

Radguard is a trademark of Radcrete Developments Pty Ltd Radcrete Developments Pty Ltd 1997 Specification details may change without notice. ACN 003 228 975 Page 1 of 3 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radguard\Page 91-92 - Instructions to Specifier.doc

RADGUARD CONCRETE & MASONRY WATER REPELLENT


1 1.1 GENERAL SCOPE This specification describes a water repellent system by means of a solution that penetrates and integrates with the concrete surface. Proprietary item: Radguard. Supplier: Radcrete Developments Pty Ltd. 1.2 RELATED DOCUMENTS Refer drawings, Preliminaries, Bill of Quantities, General Requirements, and general provisions of the contract. QUALITY SUBMISSIONS Approval before application Prior to application submit a detailed statement describing the Water Repellent system to be applied for approval. Inclusions Include literature, details, samples, warranties and the like in the submission as required. Provide the manufacturers or nominated agent/distributors written acceptance and approval of the intended system required. 2.2 QUALITY ASSURANCE Approved applicators Use applicators approved and licensed by the manufacturer or their nominated agent/distributor. Site inspection The approved applicator must inspect the site prior to commencment of application of the system, for purposes of reviewing related conditions affecting the performance requirements of this specification. Safety The site foreman/supervisor shall sight and understand the site specifications and product datasheets. All products described in this section must be used with adequate personal protection as recommended by the Material Safety Datasheet which accompanies each product shipment. 3 3.1 MATERIALS AND COMPONENTS MATERIAL General Water based alkyl silane water repellant liquid.

2 2.1

Radguard is a trademark of Radcrete Developments Pty Ltd Radcrete Developments Pty Ltd 1997 Specification details may change without notice. ACN 003 228 975 Page 2 of 3 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radguard\Page 91-92 - Instructions to Specifier.doc

4 4.1

EXECUTION APPLICATION AND SUPERVISION General Install the system in accordance to manufacturers' published recommendations. Personnel Employ trained applicators. Tools and equipment Use proper tools and equipment and working under the direct supervision of a technically competent and experienced supervisor.

4.2

SURFACE PREPARATION Surfaces to be impregnated shall be sound, air-dry and clean. Surfaces shall be free from loose or deleterious matters and residues, curing membranes and release agents. ENVIRONMENT CONDITIONS Do not apply the material When ambient temperatures are below +3oC or above +35oC. When rain is imminent (ie within 6 hours). In high wind conditions or direct sunlight.

4.3

4.4

APPLICATION Rate: Saturate surface by applying one flood coat at an application rate of 1litre per 5 sq.m. Although depending on the porosity of the surface, coverage may vary from 2.5-10 sq.m. per litre. Method: A continuously circulating airless pump system with a large bore wand plus a mozzle with a 60o fan tip, providing a nozzle pressure not greater than 70kPa shall be used to apply the material. Continuous Spraying: Must remain a liquid film for 10 seconds. Horizontal Surfaces - must have a mirror like wet look for 1 minute. Vertical Surfaces a 350mm reflective flow must be visible. Remove excess Radguard after 5 minutes.

Radguard is a trademark of Radcrete Developments Pty Ltd Radcrete Developments Pty Ltd 1997 Specification details may change without notice. ACN 003 228 975 Page 3 of 3 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radguard\Page 91-92 - Instructions to Specifier.doc

Safety:
Material Safety Data Sheet
Section 1
Use: Product Name: Other Names: Product Code: Manufacturer/Distributor:

Identification
Concrete and Masonry Water Repellent Radguard UN Number: N/A Hazchem Code: N/A Dangerous Goods Class: Radcrete Developments Pty Ltd Poison Schedule: Level 3, 45A Bay Street Pages: Double Bay NSW 2028 Date of Issue: AUSTRALIA Telephone: Jason Klaas Fax: Emergency: N/A N/A N/A N/A 2 2/12/1999 +61 (0)2 9362 3511 +61 (0)2 9362 3244 +61 (0)414 360 753

Preparer:

Section 2
Component Monomeric silanes Catalysts Water CAS No. N/A N/A 7732-18-15

Composition
% (by weight) <20% <10% >80% OSHA PEL N/K N/K N/K ACGIH N/K N/K N/K Other Limits N/A N/A N/A

Section 3
Appearance: Odour: o Viscosity (20 C) Boiling Point: Vapour Pressure: White Liquid Slight 1.00 CST N/A N/A

Physical Data
Vapour Density: Solids Content: Specific Gravity: Solubility in Water: pH: N/A N/A 0.99 Miscible N/A

Section 4
Flash Point: Flammability Limits: Auto Ignition Temperature: Extinguishing Media: Special Fire Fighting Procedures: Unusual Fire & Explosion Hazards:

Fire & Explosion Data


100 C N/A N/A Foam, water spray, CO2, dry powder N/A N/A
o

Section 5
Stability: Incompatibility: Hazardous Polymerisation: Hazardous Decomposition Products:

Reactivity Data
N/A N/A N/A Carbon Monoxide and Carbon Dioxide.

Radcrete Developments Pty Ltd 1997 Radguard is a trademark of Radcrete Developments Pty Ltd Specification details may change without notice. ACN 003 228 975 Page 1 of 2 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radguard\Page 94 - Material Safety Data Sheet.doc

Section 6
Eye Contact: Skin Contact: Inhalation: Ingestion: Chronic Hazard: Signs and symptoms of exposure: Medical conditions aggravated by exposure: First Aid Procedures: Inhalation: Eyes: Skin: Ingestion: Advice for Doctor:

Health Hazard Data


No known adverse effect No known adverse effect Vapour may cause irritation Can cause irritation to oesophegus & stomach No known chronic hazards. Not listed by OSHA, NTP or IARC as a carcinogen Sneezing, burning in nose and throat (prolonged inhalation), pain redness and tearing (eye exposure) itching or burning (prolonged skin exposure) Pre-existing skin & respiratory ailments Remove to fresh air, if symptoms still exist, seek medical advice Flush eyes with plenty of water and seek medical advice Take off all contaminated clothing; wash skin with plenty of water and soap immediately, seek medical advice if necessary Seek medical advice immediately

Section 7
Environment: Spills/Leaks: Handling and use: Storage & Transport:

Precautions for Safe Handling and Use


Keep away from drains, waters and soil Take up mechanically with an absorbent material ie sand (for damming up), sawdust, universal absorbent; Dispose with respect to local regulations Provide adequate ventilation. Application/Processing; Provide good ventilation or extraction Keep containers tightly closed and store in a cool, well ventilated place

Section 8
Respiratory Protection: Skin: Eyes: Ventilation: Other Protection: N/A = Not Applicable N/K = Not Known

Control Measures
Required if the limit values like TLV are exceeded; when vapours or aerosols occur Avoid contact where possible wear suitable protective clothing use suitable protective gloves Avoid contact use close fitting protective goggles (eg. Closed goggles) Provide adequate ventilation Do not eat, drink or smoke at workplace; Wash hands before breaks and after finishing work

Signature of Preparer Please ensure all persons coming into contact with this product are aware of the information contained in the MSDS. Information presented herein has been compiled from sources considered to be reliable to the best of our knowledge and belief but is not guaranteed to be so. It is the users responsibility to determine for themselves the suitability of any material for a specific use and to adapt safety precautions as may be necessary. If you need further information from us to make the determination which you must make to use this material safely, please contact the above named preparer.

FURTHER INFORMATION

Radcrete Developments Pty Ltd Level 3, 45a Bay Street Double Bay NSW 2028 AUSTRALIA Ph: +61 2 9362 3511 Fax: +61 2 9362 3244
ACN: 003 228 975

Radcrete Developments Pty Ltd 1997 Radguard is a trademark of Radcrete Developments Pty Ltd Specification details may change without notice. ACN 003 228 975 Page 2 of 2 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radguard\Page 94 - Material Safety Data Sheet.doc

Datasheet:
PRODUCT NAME
RadfloorTM

MANUFACTURER
Radcrete Developments Pty Ltd Level 3, 45a Bay Street Double Bay NSW 2028 SYDNEY ~ AUSTRALIA Ph: (+61-2) 9362 3511 ~ Fax(+61-2) 9362 3244 e-mail: sales@radcrete.com.au web: www.radcrete.com.au ACN: 069 156 234

yyyyyyyy @@@@@@@@ ;;;;;;;; yyyyy @@@@@ ;;;;; yy yy @@ @@ ;; ;; yyyy yy @@@@ @@ ;;;; ;; yyy yy @@@ @@ ;;; ;; yy @@ ;;
APPLICATION METHOD
Preferably a low pressure spray or alternatively roll, brush or squeegee the solution to saturate the surface. For new concrete: TM i) Apply Radfloor immediately following the finishing operation, as soon as the surface is firm enough to walk on, preferably using a low-pressure spray or squeegee. Ensure the whole surface remains TM wet with Radfloor for at least 30 minutes. ii) As Radfloor begins to dry and becomes slippery under foot, lightly mist the surface with water. iii) As the surface again begins to dry, flush the surface with water then squeegee the surface totally dry to remove any excess TM Radfloor . The surface may need to be brushed to ensure all the TM excess Radfloor is removed. For old concrete: TM i) Saturate the surface with Radfloor for at least 30 minutes. ii) If after 30-40 mins the majority of the Radfloor formula is still on TM the surface, then spread any excess Radfloor from low points or puddles over the entire surface to ensure even coverage. iii) Once it becomes slippery under foot, flush the entire surface with water and squeegee until completely dry.
TM TM

DESCRIPTION
Radfloor is a sodium silicate based liquid that penetrates reacts with available calcium to form hard, chemically inert compounds within the concrete pores.
TM

FUNCTIONS
Case Hardening Dustproofing and Consolidation Assists cleaning

TYPICAL APPLICATIONS
Car-parks Factory Floors Warehouses and Storage Facilities Driveways

PAINTING OR COVERING:
Old concrete: Allow 3-7 days before applying paint or coverings. New Concrete: Allow 28 days for proper curing.

BENEFITS
100% trafficable No V.O.C emissions Long life Non-toxic

PRECAUTIONS
Protect glass, aluminium, wood and painted finishes from contact . with RadfloorTM Avoid spraying on windy days, as overspray will cause damage to paintwork on cars.

PRODUCT PROPERTIES
Pink, odourless, soapy/slippery feel Non-toxic & Biodegradable Water based - Clean up with water No V.O.C. emissions 0 Specific gravity at 25 C 1.2 g/cc Solids Content 21% 0 Flash point - no true flash - boils at 101 C Auto ignition temperature - N/A Non-explosive Hazardous chemicals - Sodium Silicate pH - 12.5

MAINTENANCE
Wash floors with mild detergent or wet mop.

HEALTH NOTES
Eye Exposure - Severe irritation. Flush with water for 15 minutes. Skin - No known ill effects have been noted however it is recommended to wear gloves and boots during application.

LIMITATIONS
RadfloorTM is not a waterproofing compound. It does not contain any biochemical modifiers to achieve crack sealing or regrowth capacity. To achieve a long-term waterproof result and waterproofing guarantees use Radcon Formula #7.

APPLICATION

Approx. 1ltr per 5 square meters One coat required o Application limits: 3-35 C

FURTHER INFORMATION

PACKAGING AND STORAGE


RadfloorTM is available ready for use in 20ltr containers and 200ltr drums. Indefinite storage life. Ensure container is agitated before use. Radcrete Developments Pty Ltd Level 3, 45a Bay Street Double Bay NSW 2028 AUSTRALIA Ph: +61 2 9362 3511 Fax: +61 2 9362 3244
ACN: 069 156 234

Note: The information presented is intended guide only and is correct to the best of our knowledge at the time of publication. It should not be considered as a definitive approval for suitability for a particular purpose. Please contact the manufacturer, distributor or approved applicator for confirmation of suitability

TM Radfloor is a trademark of Radcrete Developments Pty Ltd Radcrete Developments Pty Ltd 1999 Specification details may change without notice. ACN 069 156 234 Page 1 of 1 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radfloor\Page 103 - Radfloor Datasheet.doc

Instructions to Specifier. Append the following Specifications and Drawings to tender and contract specifications.

TM Radfloor is a trademark of Radcrete Developments Pty Ltd Radcrete Developments Pty Ltd 1999 Specification details may change without notice. ACN 069 156 234 Page 1 of 3 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radfloor\Page 104-106 - Radfloor Instructions to Specifier.doc

RADFLOORTM CONCRETE FLOOR HARDENER


1 1.1 GENERAL

yyyyyyyy @@@@@@@@ ;;;;;;;; yyyyy @@@@@ ;;;;; yy yy @@ @@ ;; ;; yyyy yy @@@@ @@ ;;;; ;; yyy yy @@@ @@ ;;; ;; yy @@ ;;

SCOPE This specification describes a concrete hardening system by means of a solution that penetrates the concrete surface to protect, preserve and strengthen it. Proprietary item: RadfloorTM Supplier: Radcrete Developments Pty Ltd.

1.2

RELATED DOCUMENTS Refer drawings, Preliminaries, Bill of Quantities, General Requirements, and general provisions of the contract. QUALITY SUBMISSIONS Approval before application Prior to application submit a detailed statement describing the concrete hardening system to be applied for approval. Inclusions Include literature, details, samples, warranties and the like in the submission as required. Provide the manufacturers or nominated agent/distributors written acceptance and approval of the intended system required.

2 2.1

2.2

QUALITY ASSURANCE Approved applicators Use applicators approved and licensed by the manufacturer or their nominated agent/distributor. Site inspection The approved applicator must inspect the site prior to commencement of application of the system, for purposes of reviewing related conditions affecting the performance requirements of this specification. Safety The site foreman/supervisor shall sight and understand the site specifications and product datasheets. All products described in this section must be used with adequate personal protection as recommended by the Material Safety Datasheet which accompanies each product shipment.

3 3.1

MATERIALS AND COMPONENTS MATERIAL General Water based sodium silicate concrete floor hardener.

TM Radfloor is a trademark of Radcrete Developments Pty Ltd Radcrete Developments Pty Ltd 1999 Specification details may change without notice. ACN 069 156 234 Page 2 of 3 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radfloor\Page 104-106 - Radfloor Instructions to Specifier.doc

4 4.1

EXECUTION APPLICATION AND SUPERVISION General Install the system in accordance to manufacturers' published recommendations. Personnel Employ trained applicators. Tools and equipment Use proper tools and equipment and working under the direct supervision of a technically competent and experienced supervisor.

4.2

SURFACE PREPARATION Surfaces to be impregnated shall be sound, air-dry and clean. Surfaces shall be free from loose or deleterious matters and residues, curing membranes and release agents. Also ensure to protect all glass, aluminium, wood and painted finishes from contact with the material. ENVIRONMENT CONDITIONS Do not apply the material When ambient temperatures are below +3oC or above +35oC. In high wind conditions as overspray will cause damage to paintwork on cars.

4.3

4.4

APPLICATION Coverage Rate: Saturate surface by applying one flood coat at an application rate of 1litre per 5 sq.m. Although depending on the porosity of the surface, coverage may vary from 4-6 sq.m. per litre. Method: For new concrete: i) Apply the material immediately following the finishing operation, as soon as the surface is firm enough to walk on, preferably using a low-pressure spray or squeegee. Ensure the whole surface remains wet for at least 30 minutes. ii) As the material begins to dry and becomes slippery under foot, lightly mist the surface with water. iii) As the surface again begins to dry, flush the surface with water then squeegee the surface totally dry to remove any excess material. The surface may need to be brushed to ensure all the excess is removed. For old concrete: i) Saturate the surface with the material for at least 30 minutes. ii) If after 30-40 mins the majority of the formula is still on the surface, then spread any excess material from low points or puddles over the entire surface to ensure even coverage. iii) Once it becomes slippery under foot, flush the entire surface with water and squeegee until completely dry.

4.5

PAINTING OR COVERING: Old concrete: Allow 3-7 days before applying paints or coverings New concrete: Allow 28 days for proper curing.

TM Radfloor is a trademark of Radcrete Developments Pty Ltd Radcrete Developments Pty Ltd 1999 Specification details may change without notice. ACN 069 156 234 Page 3 of 3 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radfloor\Page 104-106 - Radfloor Instructions to Specifier.doc

Safety:
Section 1
Use: Product Name: Other Names: Product Code: Manufacturer/Distributor:

Material Safety Data Sheet


Identification

yyyyyyyy @@@@@@@@ ;;;;;;;; yyyyy @@@@@ ;;;;; yy yy @@ @@ ;; ;; yyyy yy @@@@ @@ ;;;; ;; yyy yy @@@ @@ ;;; ;; yy @@ ;;

Preparer:

Silicate based floor sealing, hardening and dust-binding material for concrete Radfloor UN Number: N/A N/A Hazchem Code: N/A N/A Dangerous Goods Class: N/A Radcrete Pacific Pty Ltd Poison Schedule: N/A Level 3, 45A Bay Street Pages: 2 Double Bay NSW 2028 Date of Issue: 23/2/98 AUSTRALIA Telephone: +61 (0)2 9362 3511 Jason Klaas Fax: +61 (0)2 9362 3244 Emergency: +61 (0)414 360 753

Section 2
Component Sodium Silicates Water Sodium Di iso-octyl-sulphonocianate Ethanol CAS No. 1344-09-8 7732-18-5 577-11-7 64-17-15

Composition
% (by weight) <40 >60 0.5 0.12 N/K N/K N/K OSHA PEL N/K ACGIH N/K Other Limits N/K

Section 3
Appearance: Odour: Boiling Point: Vapour Pressure: Colourless liquid Low Odour o 101 Celsius N/A water based

Physical Data
Vapour Density: Solids Content: Specific Gravity: Solubility in Water: pH: N/A 12% 1.12 Complete 11.5

Section 4
Flash Point: Flammability Limits: Auto Ignition Temperature: Extinguishing Media: Special Fire Fighting Procedures: Unusual Fire & Explosion Hazards:

Fire & Explosion Data


Non-combustible N/A N/A N/A N/A N/A

Section 5
Stability: Incompatibility: Hazardous Polymerisation: Hazardous Decomposition Products:

Reactivity Data
Stable Gels when mixed with acid Will not occur N/A

TM Radfloor is a trademark of Radcrete Developments Pty Ltd Radcrete Developments Pty Ltd 1999 Specification details may change without notice. ACN 069 156 234 Page 1 of 2 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radfloor\Page 108-109 - Radfloor Material Safety Data Sheet.doc

Section 6
Eye Contact: Skin Contact: Inhalation: Ingestion: Chronic Hazard: Signs and symptoms of exposure: Medical conditions aggravated by exposure: First Aid Procedures: Inhalation: Eyes: Skin: Ingestion: Advice for Doctor:

Health Hazard Data


Causes eye irritation Can cause skin irritation Can cause irritation to respiratory tract Can cause irritation to oesophagus & stomach No known chronic hazards. Not listed by OSHA, NTP or IARC as a carcinogen Sneezing, burning in nose and throat (prolonged inhalation), pain redness and tearing (eye exposure) itching or burning (prolonged skin exposure) Pre-existing skin & respiratory ailments Remove to fresh air Flush eyes with water for at least 20 minutes Wash skin with soap and water, remove and wash contaminated clothing Dilute by drinking large amounts of water or milk allowing vomiting to occur. Do not induce vomiting. Seek medical advice Treat as for alkaline material

Section 7
Spills/Leaks: Handling and use: Storage & Transport:

Precautions for Safe Handling and Use


Take up spills with sand, soil or other absorbent materials and place in sealed containers for disposal. Contaminated area can be washed clean with warm detergent solution. Keep spills and cleaning run offs out of municipal sewers and open bodies of water. Wash after handling and before eating, drinking, smoking. Keep in sealed containers No special precautions required

Section 8
Respiratory Protection: Skin: Eyes: Ventilation: Other Protection: N/A = Not Applicable N/K = Not Known

Control Measures
Where spraying use a filter face mask In enclosed areas use a cartridge type respirator NIOSH approved Avoid contact wear suitable protective clothing use rubber gloves Avoid contact use chemical goggles Provide adequate ventilation Safety shower and eyewash fountain should be within direct access

Signature of Preparer Please ensure all persons coming into contact with this product are aware of the information contained n the MSDS. Information presented herein has been compiled from sources considered to be reliable to the best of our knowledge and belief but is not guaranteed to be so. It is the users responsibility to determine for themselves the suitability of any material for a specific use and to adapt safety precautions as may be necessary. If you need further information from us to make the determination which you must make to use this material safely, please contact the above named preparer.

FURTHER INFORMATION

Radcrete Pacific Pty Ltd Level 3, 45a Bay Street Double Bay NSW 2028 AUSTRALIA Ph: +61 2 9362 3511 Fax: +61 2 9362 3244
ACN: 003 228 975

TM Radfloor is a trademark of Radcrete Developments Pty Ltd Radcrete Developments Pty Ltd 1999 Specification details may change without notice. ACN 069 156 234 Page 2 of 2 04/06/03 All rights reserved C:\My Library RadPac\Binders\Rewards Binder\Radfloor\Page 108-109 - Radfloor Material Safety Data Sheet.doc

Potrebbero piacerti anche