INSTALATION MANUAL LOGA2 car pulse window controller

Detailed description of the LOGA2 function:


Impulse Control Pulse action button (short, fast pressure release), the window moves. Pulse again by pressing any key (up or down), the window stops. During the movement, if the window meets the burden, an obstacle or get to the end of its path, the window stops. Automat LOGA2 comes programmed to operate with the load that has a window in Dacia Logan. The user can customize it to own window if it notices that the window will not be raised and lowered to the end, but along the way stops. The reason for this stop is a dirty glass window or guides, and certainly the first to overcome these shortcomings. In the winter it is possible that the window freezes, and user should not force windows. If you want to set the device to work optimally with your window, then do the procedure to store loads. Restore saved initial load can be done as described in the Reset memory load. Saving the load to memory The ability to store loads to which the window stops. The procedure is as follows: Window is first raised to the top, and then press and hold down the button. The window moves down, and after 7 seconds, the window motor is turned off (you hear a "click" from LOGA2 controller). Continue to hold down button and after 20 seconds the window start to moving up. At this point release button and a controller step into the saving load mode. The window rises to the top. Once window get to the top, it is necessary to wait a few seconds and automatic save the load for a particular window is done. Each new procedure to store the load clears the old values and stores a new load value. Reset memory load Returns saved loads on initial value. The initial value is value of the load provided by the window of a Dacia Logan car. The procedure is as follows: Lower the window to go down to the end. Press and hold up button to rise the window. The window moves up and after 7 seconds, the window motor is turned off (you hear a "click" from LOGA2 controller). Still hold up button, and after 20 seconds the window twice briefly go down. As soon as the window goes down is indication that the reset is done. Release the button. After this reset of the memory load is done. Normal control Long holding the controll button moves window as long as the button is pressed. Upon release button, the window stops. If you long hold the down button, controller will stop the window when it come to the bottom end position (or when it feel the burden). If you long hold the up button, controller will not stop the window when it come to the top, but we have to turn off the key alone. Forced raising possibility was left in the event that the
2

LOGA2 controller is designed to control the raising and lowering car windows or managing roof panel (sunroof). Instalation is very easily, between the existing window control button and connectors that lead to electric motors to drive the window. Controller has the same basic functions and layout of connection outlets as well as Renault's pulsed button, built in the Renault Logan:

Features:
Easy plug and play installation No additional wires One-touch calibration Remote input (X3) Impulse Control (briefly pressing the control key, the window is raised (lowered) to the end and then stopped), Saving the load (the ability to store loads to which the window stops) Reset memory load (the possibility of returning to the initial load stored value), Normal control (long holding the window moves as long as the button is pressed. The release button, the window stops) Safety timer (maximum working time in one cycle (raising or lowering) is limited to 7 seconds for safety) LOGA2 is scheduled to work at el. installation of DC voltage 12V (14.3V) and can be used with the car window motors which current is up to 13 amperes. H=16mm, W=33mm, L=80mm + 40mm wires Weight: 50 gr. Before any action with the controller read the instructions for installation and see a schematic block diagram.
1

LOGA2 instalation manual v1.0

26.10.2010.

LOGA2 instalation manual v1.0

26.10.2010.

glass is dirty and hard to raise. Of course, it is necessary to clean the glass or lubricate his conduct, so LOGA2 controller or mechanism for raising the window would not be damaged. Safety timer protection Controller maximum working time in one cycle is limited to 7 seconds for safety. This means the following: in the short or long press a key, window move in raising (or lowering). If the window did not come up until the end of a time of 7 seconds, the window itself stops, and the command-raising (lowering) need to be repeated. This is the time required for window glass to cross the worst travell conditions of a fully open to fully closed. The safety timer can be extended or shortened if you incorporating LOGA2 at another vehicle (not Dacia Logan/Sandero). If you need other time than 7 seconds, you must required it when you order the device. LOGA2 is built to work at electrical circuit of DC voltage 12V (14.3V) and can control motors with operating current up to 13A. Labels and layout connectors on LOGA2 controller

Installation of LOGA2 controller Before installing make sure that you remove ignition key! Instalation is very easily between the existing window control button and connectors that lead to electric motors to drive the window. First, take out the existing common key to control the window. Use small flat screwdriver to carefully separate the key from the console. Use screwdriver from the bottom and from the top side .

ID - the serial number of unit X1 - connection to the command key-switch X2 - connection to the window lifter motor X3 - access to remote control automation - can be used in combination with other device for automatically lifting(lowering) window (example: rise window at the door lock) X3 signal level: +12V, 50mA. If signal is shorter then 300ms, controller will act as pulse controll. If signal is longer then 300ms, controller will act as normal controll. X3-1 - remote window lifting (the same function as X1-1) X3-2 - remote window lowering (same function as the X1-5) For details, see the block scheme of connections Block Schematic LOG A2.pdf

LOGA2 instalation manual v1.0

26.10.2010.

LOGA2 instalation manual v1.0

26.10.2010.

Key switch is needed to be separate from the connector. It is necessary to gently stretch each of the contacts, for better conducting. We should be careful not to overdo it and break something.

After that, mount other LOGA2 connector, also taking into account the orientation of conductors.

. On the first, mount controller LOGA2 to existing key switch, taking into account the arrangement of conductors and the switch orientation over conductor colors.

After installation:
X3: 2 1 X1: 5 4 3 2 1

5 4 3 2 1

LOGA2 instalation manual v1.0

26.10.2010.

LOGA2 instalation manual v1.0

26.10.2010.

Now you need to test if everything works properly. First, check again that everything is connected properly, and then insert the ignition key and make contact. Include positional lights (daylights/headlights) to verify bright light inside the button:

After this test the lifting and lowering the window, and then slowly return all parts to the central console:

Upon completion of installation you need to do storage load to teach the LOGA2 controller to your window load.

Happy working! Vladimir Stojakovi email: stojakovicv@gmail.com mob: +381-64-144-6658