Parker 60 Series spring return (AC/AO) or double acting (AD) rack and pinion actuators are compact, simply designed devices that are quality engineered to provide high torque outputs and a high cycle, trouble-free life. A compact, dual opposed rack and pinion design and guide band suspension combine to produce a symmetrically balanced, center mount actuator. In addition, the actuator has a short powerful stroke, rapid response, and fully concentric operating load capability which ensures optimum performance.
Features
Three point suspension system uses carbon filled PTFE guide bands for piston alignment and rack support Dual opposed piston design uses air pressure on two pistons to deliver a balanced force to the pinion gear Patented balanced piston design results in even distribution of bearing loads and eliminates piston tilting Multiple spring concept permits actuator use at 40 to 120 psig (2.8 to 8.3 bar) air supply requirements Suitable for use with dry or lubricated air, non-corrosive gas, or light hydraulic oil Aluminum alloy body construction with two component polyurethane coating Manual override
Specifications
Operating Pressure 90 Models: 40 to 120 psig (2.8 to 8.3 bar) maximum AC Normally Closed Spring Return AD Double Acting AO Normally Open Spring Return 180 Models: 80 psig (5.5 bar) maximum ACX Spring Return ADX Double Acting Temperature Range -4 F to 175 F (-20 C to 79 C) Optional high and low temperature ranges available
Options
Solenoid valve Rotary limit switch with valve position indicator Breather block Dual mount actuator
Operation
Actuators are manufactured with an integral air manifold and internal porting. The air manifold is designed for direct mounting of solenoid valves. This eliminates the need for external tubing and simplifies installation. For applications not requiring a solenoid valve, the air manifold inlet ports are marked A and B. Air inlet port A will rotate the actuator counter-clockwise. Spring return actuators fail clockwise.
61S Option
Compact single piston design Available for MB, HB, B2, and B6 Series Valves
Pneumatic Actuators
Dimensional Data for 61 and 61S Models
UNC 10-24 X.31 DEEP 2 PLACES 1.75 (44.5) 1/8" NPT 2 PLACES
1.75 (44.5) UNC 10-24 X.31 DEEP 2 PLACES 1/8" NPT 2 PLACES
C 2.36 (59.9)
2.36 (59.9)
61S Actuator
61SAD Dim
A B C
61 Actuator
( ) Denotes dimensions in millimeters 61SAC/O Inch mm
3.66 3.38 93.0 85.9
61SADX Inch
4.63 3.38
61SACX mm Inch
5.83 3.38
Inch
3.37 3.38
mm
85.6 85.9
mm
148.1 85.9
117.6 85.9
61AD Dim
A B C1 C2
Inch
4.06 3.38 2.36
mm
103.1 85.9 59.9
61AC/O Inch mm
4.65 3.38 2.36 118.1 85.9 59.9
61ADX Inch
6.10 3.38 2.36
mm
154.9 85.9 59.9
61ACX Inch
8.50 3.38 2.36
mm
215.9 85.9 59.9
Dimensional Data for 62, 63, 64, 65, 66, 68 and 69 Models
1.75 (44.5) UNC 10-24 X.31 DEEP 4 PLACES 1/4" NPT 2 PLACES
C F
1.26 (32.0) D
0.95 (24.1) A B
A Model 62AD 62AC/O 63AD 63AC/O 64ADX 64ACX 65AD 65AC/O 66AD 66AC/O 68ADX 68ACX 69AD 69AC/O Inch 6.26 7.09 6.34 7.83 8.7 7.28 11.14 mm 159.0 180.1 161.0 198.9 221.0 184.9 283.0 Inch 6.77 8.03 7.17 9.8 10.51 8.5 14.17
B Single Mount mm 172.0 204.0 182.1 248.9 267.0 215.9 359.9 Inch 4.17 4.17 4.68 4.68 5.00 5.00 5.15 5.15 5.67 5.67 6.33 6.33 6.65 6.65 mm 105.9 105.9 118.9 118.9 127.0 127.0 130.8 130.8 144.0 144.0 160.8 160.8 168.9 168.9
C Dual Mount Inch 3.15 3.15 3.86 3.86 3.98 3.98 4.13 4.13 4.65 4.65 5.31 5.31 5.63 5.63 mm 80.0 80.0 98.0 98.0 101.1 101.1 104.9 104.9 118.1 118.1 134.9 134.9 143.0 143.0 Inch 1.26 1.26 1.32 1.32 1.69 1.69 1.54 1.54 1.59 1.59 2.09 2.09 1.99 1.99
D mm 32.0 32.0 33.5 33.5 42.9 42.9 39.1 39.1 40.4 40.4 53.1 53.1 50.5 50.5 Inch 2.91 2.91 3.39 3.39 4.27 4.27 3.86 3.86 4.25 4.25 5.61 5.61 5.04 5.04
E mm 73.9 73.9 86.1 86.1 108.5 108.5 98.0 98.0 108.0 108.0 142.5 142.5 128.0 128.0 Inch 3.15 3.15 3.66 3.66 3.98 3.98 4.13 4.13 4.65 4.65 5.31 5.31 5.63 5.63
F mm 80.0 80.0 93.0 93.0 101.1 101.1 104.9 104.9 118.1 118.1 134.9 134.9 143.0 143.0
Pneumatic Actuators
SEE PAGE 3
C*
D* E*
A Inch
2.23 2.49 2.91 2.33 2.33 2.48 2.70 2.94 3.03 3.27 3.46 3.73 3.92
B* mm
56.6 63.2 73.9 59.2 59.2 63.0 68.6 74.7 77.0 83.1 87.9 94.7 99.6
Inch
mm
Inch
1.61
40.9
0.80
20.3
0.75
19.1
1.50
38.1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Double Acting AD
61AD or 61SAD 61AD or 61SAD 61ADX or 61SADX 61ADX or 61SADX 61AD or 61SAD 61AD or 61SAD 61AD or 61SAD 61AD or 61SAD 61AD or 61SAD 61ADX or 61SADX 61ADX or 61SADX 61ADX or 61SADX 61ADX or 61SADX 61ADX or 61SADX 61AD 61AD 61AD 61AD 61ADX 61ADX 61ADX 61ADX 61AD 61AD 61ADX 61ADX 61AD or 61SAD 61AD or 61SAD 61ADX or 61SADX 61AD or 61SAD 61AD or 61SAD 61ADX or 61SADX 61AD or 61SAD 61AD or 61SAD 61ADX or 61SADX
Spring Return AO
61AO-2 or 61SAO 61AO-2 or 61SAO 61ACX-2 or 61SACX 61ACX-2 or 61SACX 61AO-2 or 61SAO 61AO-2 or 61SAO 61AO-2 or 61SAO 61AO-2 or 61SAO 61AO-2 or 61SAO 61ACX-2 or 61SACX 61ACX-2 or 61SACX 61ACX-2 or 61SACX 61ACX-2 or 61SACX 61ACX-2 or 61SACX 61AO-2 62AO-3 62AO-3 62AO-3 61ACX-2 64ACX-12 64ACX-12 64ACX-12 62AO-3 61AO-2 64ACX-8 61ACX-2 61AO-2 or 61SAO 61AO-2 or 61SAO 61ACX-2 or 61SACX 61AO-2 or 61SAO 61AO-2 or 61SAO 61ACX-2 or 61SACX 61AO-2 or 61SAO 61AO-2 or 61SAO 61ACX-2 or 61SACX
Spring Return AC
61AC-2 or 61SAC 61AC-2 or R 61SAC 61ACX-2 or 61SACX 61ACX-2 or 61SACX 61AC-2 or 61SAC 61AC-2 or 61SAC 61AC-2 or 61SAC 61AC-2 or 61SAC 61AC-2 or 61SAC 61ACX-2 or 61SACX 61ACX-2 or 61SACX 61ACX-2 or 61SACX 61ACX-2 or 61SACX 61ACX-2 or 61SACX 61AC-2 62AC-3 62AC-3 62AC-3 61ACX-2 64ACX-12 64ACX-12 64ACX-12 62AC-3 61AC-2 64ACX-8 61ACX-2 61AC-2 or 61SAC 61AC-2 or 61SAC 61ACX-2 or 61SACX 61AC-2 or 61SAC 61AC-2 or 61SAC 61ACX-2 or 61SACX 61AC-2 or 61SAC 61AC-2 or 61SAC 61ACX-2 or 61SACX
Pneumatic Actuators
Suggested Actuators for SB Series Ball Valves
Actuators were sized in this table using the maximum allowable pressure differential across the seats with a 1.20 multiplier for application factor. Please determine, by reading page 6, if the media or service conditions would render the information in this table questionable. Actuators for SB Series Ball Valves may also be downsized to fit the application using the technique found on page 6.
Valve Size T Seats SB8 SB12 SB16 SB20 SB24 SB32 RT Seats SB8 SB12 SB16 SB20 SB24 SB32
Two-way Valves SBL Double Acting Spring Return AD AC/AO 60 psig 80 psig 60 psig 80 psig (4.1 bar) (5.5 bar) (4.1 bar) (5.5 bar) 61AD 61AD 62AD 62AD 63AD 63AD 61AD 61AD 62AD 63AD 63AD 66AD 61AD 61AD 62AD 63AD 63AD 66AD 61AD 63AD 63AD 65AD 66AD 69AD 61AD 61AD 62AD 62AD 63AD 63AD 61AD 62AD 62AD 65AD 66AD 69AD 61AD 61AD 61AD 62AD 62AD 63AD 61AD 61AD 61AD 63AD 63AD 65AD 61AD 61AD 61AD 62AD 63AD 65AD 61AD 62AD 63AD 63AD 65AD 66AD 61AD 61AD 62AD 62AD 62AD 63AD 61AD 61AD 61AD 63AD 65AD 66AD 62AC-3 62AC-3 63AC-3 65AC-3 66AC-3 69AC-3 62AC-3 62AC-3 63AC-3 69AC-3 69AC-3 69AC-3 62AC-3 62AC-3 63AC-3 66AC-3 66AC-3 69AC-3 63AC-3 66AC-3 69AC-3 69AC-3 69AC-3 61AC-2 61AC-2 63AC-3 63AC-4 65AC-4 66AC-4 61AC-2 62AC-3 63AC-3 66AC-4 66AC-4 69AC-3 61AC-2 62AC-3 63AC-3 64AC-4 66AC-3 69AC-3 63AC-4 65AC-4 66AC-4 69AC-4 69AC-4 69AC-4 62AC-3 62AC-4 63AC-4 64AC-4 65AC-4 66AC-4 63AC-3 63AC-3 63AC-4 66AC-4 69AC-4 69AC-4
Valve Size T Seats SB8 SB12 SB16 SB24 SB32 RT Seats SB8 SB12 SB16 SB24 SB32 PF Seats SB8 SB12 SB16 SB24 SB32 PKP Seats SB8 SB12 SB16 SB24 SB32 UPE Seats SB8 SB12 SB16 SB24 SB32 DE Seats SB8 SB12 SB16 SB24 SB32
Three-way Diverter Valves SBXD Double Acting Spring Return AD AC 60 psig 80 psig 60 psig 80 psig (4.1 bar) (5.5 bar) (4.1 bar) (5.5 bar) 61ADX 61ADX 64ADX 64ADX 68ADX 61ADX 61ADX 61ADX 68ADX 61ADX 61ADX 61ADX 64ADX 68ADX 61ADX 61ADX 61ADX 68ADX 68ADX 61ADX 61ADX 64ADX 64ADX 68ADX 61ADX 64ADX 68ADX 68ADX 64ACX-8 64ACX-8 64ACX-8 61ACX-2 61ACX-2 68ACX-2 68ACX-12
Valve Size
Three-way Selector Valves SBX Double Acting Spring Return AD AC 60 psig 80 psig 60 psig 80 psig (4.1 bar) (5.5 bar) (4.1 bar) (5.5 bar) 61ADX 64ACX-8 64ACX-8 61ADX 68ACX-8 64ACX-12 61ADX 68ACX-8 68ACX-8 64ADX 68ADX
T Seats SB8 61ADX SB12 61ADX SB16 64ADX SB24 SB32 68ADX 68ADX
*
64ACX-8 64ACX-8 68ACX-8
*
61ACX-2 64ACX-8 68ACX-8
* *
* *
* *
* *
PF Seats SB8 61ADX SB12 64ADX SB16 64ADX SB24 SB32 68ADX 61ADX 68ACX-8 64ACX-12 61ADX 68ACX-8 68ACX-8 64ADX 68ACX-12 68ADX 68ADX
PF Seats SB8 SB12 SB16 SB20 SB24 SB32 PKP Seats SB8 SB12 SB16 SB20 SB24 SB32 UPE Seats SB8 SB12 SB16 SB20 SB24 SB32 DE Seats SB8 SB12 SB16 SB20 SB24 SB32
* *
* *
* *
* *
* * *
64ACX-8 64ACX-8 68ACX-8
* * *
64ACX-8 64ACX-8 68ACX-8 68ACX-12 68ACX-12 UPE Seats SB8 61ADX SB12 64ADX SB16 64ADX SB24 SB24 68ADX 68ADX
62AC-3 63AC-3 65AC-3 65AC-3 66AC-3 69AC-4 63AC-3 63AC-3 65AC-3 69AC-3 69AC-3
*
61ADX 61ADX 64ADX 64ADX 68ADX 61ADX 64ADX 64ADX 68ADX
*
61ADX 61ADX 61ADX 64ADX 64ADX 61ADX 61ADX 61ADX 68ADX
61ADX 68ACX-8 64ACX-10 61ADX 68ACX-8 68ACX-8 64ADX 68ACX-10 68ACX-10 68ADX 68ADX
* *
* *
* *
* *
Pneumatic Actuators
Determination of Valve Torque
By properly sizing an actuator to a valve for a specific application, performance is guaranteed and economies are gained. Before an actuator can be sized for an application, the amount of torque required must be determined. The operating torque of a ball valve is influenced by the design, seat material, and application (service) conditions. Stem torque is primarily dependent upon the tightness of the stem nut. The design of the SB Series Ball Valve is such that the stem torque is constant. Ball/seat torque is created by the friction between the ball and seat and is also very sensitive to service conditions. The floating ball design concept allows the system pressure to force the ball into the downstream seat. The higher the system pressure, the harder the ball is forced into the downstream seat, and, therefore, the higher the torque. Also, since different seat materials have different coefficients of friction, the ball/seat torque also becomes a function of the seat material being used. Valve torque is also a function of the media flowing through the valve. Abrasive medias have a tendency to increase the amount of friction between the ball and seats, whereas some light oils, which provide additional lubricity, may reduce the amount of torque required. The pressure torque curves on page 7 are the result of laboratory testing using water at ambient temperature as the medium. Torque values derived from these curves, when the appropriate service condition correction factors are applied, will be adequate for the vast majority of applications. Based upon the valve size, seat material, and differential pressure across the valve (in the closed position), the amount of torque required may be determined using the following procedure: 1. Find the valve torque from the appropriate curve by using the differential pressure. Locate the differential pressure on the horizontal axis of the chart and move up until you arrive at the appropriate valve size. Transfer the intersecting point across to the vertical axis of the graph and read the required torque. Multiply this torque by the service and media application factor multipliers. The maximum combined multiplier should never be greater than 2. 3.
Application Factor
A. Service On-Off Emergency shutdown (cycled less than once per month) Applications with less than two cycles per day Applications below 20 F (-29 C) B. Media Saturated steam Clean saturated steam Liquid, clean (particle free) Liquid, dirty (slurry), raw water Gas, clean and wet Gas, clean and dry (superheated stm.) Gas, dirty (natural gas) Chlorine
Multiplier
1.00 2.00 1.20 1.25
Actuator Selection
When the torque requirements have been determined, the actuator may be properly sized. 1. Double Acting Operation (AD) Select the actuator whose torque output, at the minimum air supply pressure, exceeds the calculated torque. Actuator torque output charts are shown on pages 8 and 9. Spring Return Operation, Fail Closed (AC) Select the actuator whose spring torque output exceeds the calculated torque. Actuator torque output charts are shown on pages 8 and 9. In addition, check the selected actuator to insure the air torque output at the minimum air supply pressure also exceeds the calculated torque. Spring Return Operation, Fail Open (AO) Select the actuator whose spring torque output exceeds the calculated torque. Actuator torque output charts are shown on pages 8 and 9. In addition, check the selected actuator to insure the air torque output at the minimum air supply pressure also exceeds the calculated torque.
2.
2.
Pneumatic Actuators
SB Series Pressure Torque Curves: Two-way (L) and Three-way (XD) Diverter Valves
Differential Pressure (bar) Differential Pressure (bar) Differential Pressure (bar)
17
34
51
68
SB32
17
34
51
68
86
SB32
103
17
34
51
68
86
SB32
103
250 200
28 22
500 400
Torque (In-lb)
Torque (Nm)
57 45
Torque (Nm)
45 39 34
Torque (Nm)
Torque (Nm)
SB24
Torque (In-lb)
150 100 50
SB8 & SB12 SB20 SB16
17 11 6 0
0 250 500 750 1000
300
SB24
34 23
SB20
28 22 17 11 6 0
0 250 500 750 1000 1250 1500
Differential Pressure (psig)
200 100
SB16
11
SB8 & SB12
0
0
T Seats
Differential Pressure (bar)
RT Seats
Differential Pressure (bar)
PF Seats
Differential Pressure (bar)
17 34
51
68
86
103
17 34
51
68
86
103
34 68
103
137 172
206
600 500
Torque (In-lb)
68
SB32
250 200
SB32
Torque (In-lb)
Torque (Nm)
28 22
Torque (In-lb)
600
SB32
68 57
SB24
Torque (Nm)
57 45
45 34 23
SB8, SB12, & SB16
34 23 11 0
150 100 50 0
0
17 11 6 0
Torque (Nm)
200 100 0
11 0
PKP Seats
UPE Seats
DE Seats
0
55
14
28
41
55
14
28
SB32
41
55
14
28
SB32
41
400
28
Torque (In-lb)
45
SB32
200 175
Torque (In-lb)
23
250 200
Torque (In-lb)
39
Torque (Nm)
22
SB24
Torque (Nm)
34 28 22
SB24
SB24
17
150 100
17 11
11
SB16
SB16
17 11
50
SB8, & SB12
6 0
800
6
SB8, & SB12
0
0 200 400 600
Differential Pressure (psig)
0
0 200 400 600 800
Differential Pressure (psig)
0
0 200 400 600 800
Differential Pressure (psig)
T Seats
PF Seats
7
UPE Seats
Parker Hannifin Corporation Instrumentation Valve Division Jacksonville, Alabama
Pneumatic Actuators
90 Models (AC, AO, and AD) Performance Characteristics
Weight Series 61 61S 62 63 65 66 69 Bore Inch mm 1.8 45.7 1.8 45.7 2.2 55.9 2.8 71.1 3.1 78.7 3.6 91.4 4.3 109.2 Inch 0.5 0.5 0.6 0.7 0.9 1.0 1.5 Stroke mm 12.7 12.7 15.2 17.8 22.1 25.4 38.1 AD lb 1.3 1.2 2.9 4.0 5.3 6.8 12.8 kg 0.6 0.5 1.3 1.8 2.4 3.1 5.8 lb 1.5 1.2 3.7 5.3 7.9 10.1 20.1 AC/AO kg 0.7 0.6 1.7 2.4 3.6 4.6 9.1 Operating Time sec 0.4 0.4 0.5 0.7 1.1 1.2 2.3 Air Consumption in3 Port A Port B+ 3.1 3.7 2.4 1.2 6.1 6.7 9.8 13.4 20.1 22.0 21.4 29.9 49.0 61.0 Air Consumption cc Port A Port B+ 50.8 60.7 39.3 19.7 100.0 109.8 160.7 219.7 329.5 360.7 350.8 490.2 803.3 1000.0
AD Torques
Series 61 61S 62 63 65 66 69 40 psig (2.8 bar) in-lb 59 109 205 312 461 1011 Nm 6.7 12.3 23.2 35.2 52.1 114.2 60 psig (4.1 bar) in-lb 89 45 165 309 471 696 1527 Nm 10.1 5.1 18.6 34.9 53.2 78.6 172.5 80 psig (5.5 bar) in-lb 119 59 220 413 630 930 2042 Nm 13.4 6.7 24.9 46.7 71.2 105.1 230.7 100 psig (6.9 bar) in-lb 149 75 276 518 789 1165 2557 Nm 16.8 8.5 31.2 58.5 89.1 131.6 288.9
AC and AO Torques
Series 61 61S Spring Set 2 2 3 4 5 6 2 3 4 5 6 2 3 4 5 6 2 3 4 5 6 2 3 4 5 6 40 psig (2.8 bar) in-lb 44 8 82 15 117 10 192 43 406 73 Nm 5.0 0.9 9.3 1.7 13.2 1.1 21.7 4.9 45.9 8.2 Air Torque 60 psig (4.1 bar) 80 psig (5.5 bar) in-lb 23 16 103 66 31 193 126 58 285 178 72 441 293 143 952 620 287 Nm 2.6 1.8 11.6 7.5 3.5 21.8 14.2 6.6 32.2 20.1 8.1 49.8 33.1 16.2 107.6 70.0 32.4 in-lb 55 21 162 126 90 54 18 304 236 169 101 34 453 347 240 133 26 690 542 392 244 95 1498 1165 833 500 167 Nm 6.2 2.4 18.3 14.2 10.2 6.1 2.0 34.3 26.7 19.1 11.4 3.8 51.2 39.2 27.1 15.0 2.9 78.0 61.2 44.3 27.6 10.7 169.2 131.6 94.1 56.5 18.9 100 psig (6.9 bar) in-lb 87 26 220 185 149 113 77 413 346 279 212 144 622 515 408 301 195 939 790 641 492 344 2043 1711 1378 1045 713 Nm 9.8 2.9 24.9 20.9 16.8 12.8 8.7 46.7 39.1 31.5 24.0 16.3 70.3 58.2 46.1 34.0 22.0 106.1 89.3 72.4 55.6 38.9 230.8 193.3 155.7 118.1 80.6 in-lb 41 21 39 58 78 98 117 74 110 146 183 220 117 175 234 292 351 161 242 323 403 484 361 543 723 904 1085 Spring Torque Nm 4.6 2.4 4.4 6.6 8.8 11.1 13.2 8.4 12.4 16.5 20.7 24.9 13.2 19.8 26.4 33.0 39.7 18.2 27.3 36.5 45.5 54.7 40.8 61.3 81.7 102.1 122.6
62
63
65
66
69
Pneumatic Actuators
180 Models (ACX AND ADX) Performance Characteristics
Weight Series 61 61S 64 68 Inch 1.8 1.8 3.2 4.3 Bore mm 45.7 45.7 81.3 109.2 Inch 1.0 1.0 0.7 1.0 Stroke mm 25.4 25.4 17.8 25.4 lb 1.9 1.4 5.5 11.6 AD kg 0.9 0.7 2.5 5.3 lb 2.4 1.7 6.4 13.6 AC kg 1.1 0.8 2.9 6.2 Operating Time sec 0.8 0.8 1.5 2.8 Air Consumption in3 Port A Port B+ 4.5 5.7 6.1 3.1 16.0 23.0 37.0 49.0 Air Consumption cc Port A Port B+ 73.8 93.4 100.0 50.0 262.3 377.0 606.6 803.3
ADX Torques
40 psig (2.8 bar) Series 61 61S 64 68 in-lb 59 139 351 Nm 6.7 15.7 39.7 in-lb 89 45 210 530 Nm 10.1 5.1 23.7 59.9 in-lb 119 59 281 709 Nm 13.4 6.7 31.7 80.1 60 psig (4.1 bar) 80 psig (5.5 bar)
ACX Torques
Air Torque Series 61 61S 64 Spring Set 2 8 10 12 14 8 10 12 14 40 psig (2.8 bar) in-lb 19 76 Nm 2.1 8.6 60 psig (4.1 bar) in-lb 25 16 90 60 30 255 186 117 48 Nm 2.8 1.8 10.2 6.8 3.4 28.8 21.0 13.2 5.4 80 psig (5.5 bar) in-lb 57 21 161 131 101 71 433 365 296 227 Nm 6.4 2.4 18.2 14.8 11.4 8.0 48.9 41.2 33.4 25.6 in-lb 39 21 62 78 93 109 150 187 225 262 Spring Torque Nm 4.4 2.4 7.0 8.8 10.5 12.3 16.9 21.1 25.4 29.6
68
Pneumatic Actuators
SB Series Actuator Sizing Examples
EXAMPLE 1 Valve Desired: 24Z-SB24L-PF-T-SS Actuator Desired: Spring Return, Normally Closed Differential Pressure: 250 psig Minimum Air Supply Pressure: 80 psig Service: On-off Media: Raw Water Calculation From the PF Seal Pressure-Torque graph on page 7: Torque at 250 psig = 170 in-lb Service Factor from page 6: Multiplier = 1.00 Media Factor from page 6: Multiplier = 1.80 Application Operating Torque = Operating Torque x Application Factor = 170 in-lb x 1.00 x 1.80 = 306 in-lb From the AC Spring Torques on page 8, proceed down the table looking for a torque exceeding 306 in-lb. The 65AC-6 meets the requirement, but the Air Torque at 80 psig does not. Repeat this step to find a larger actuator. The next actuator in the table to meet both requirements is the 66AC-4. Valve Model: 24Z-SB24L-PF-T-SS-66AC-4 EXAMPLE 2 Valve Desired: 12A-SB12L-T-SS Actuator Desired: Spring Return, Normally Open Differential Pressure: 400 psig Minimum Air Supply Pressure: 60 psig Service: -20 F Media: Dirty Gas Calculation From the T Seal Pressure-Torque graph on page 7: Torque at 400 psig = 30 in-lb Service Factor from page 6: Multiplier = 1.25 Media Factor from page 6: Multiplier = 1.50 Application Operating Torque = Operating Torque x Application Factor = 30 in-lb x 1.25 x 1.50 = 57 in-lb From the AC Spring Torques on page 8, proceed down the table looking for a torque exceeding 57 in-lb. The 62AO-3 meets the requirement for both Spring Torque and Air Torque. Valve Model: 12A-SB12L-T-SS-62AO-3
Options
High Temperature Seals Extends the high temperature from 175 F (79 C) to 250 F (121 C) and to 400 F (204 C) on special Series 62 and 63 90 models. Low Temperature Seals Extends the low temperature from 4 F (-20 C) to 40 F (-40 C). Solenoid Valve (Single coil) Mounts directly to the actuator inlet manifold. NEMA 4 or 7 housings with voltages of 24 VDC, 120 VAC, and 240 VAC. A manual override is standard. Limit Switch Rugged, fully enclosed unit contains two SPDT snap-acting switches operated by two independently adjustable cams on a rotating shaft coupled directly to the actuator auxiliary drive. Features a visual valve position indicator. Meets NEMA 4, 7, and 9 classifications for weather-resistant and hazardous locations. Breather Block A direct mount diverter module redirects instrument quality air to the spring chamber during the spring stroke (fail stroke) of AC and AO actuators. Ideal for corrosive, wet, or dusty environments. Also improves spring stroke speed and allows the solenoid valve to be mounted to it. Dual Mount Actuator Two valves may be actuated with a single actuator. Available with both valves open, both closed, or one open and one closed. NOTE: Parker pneumatically actuated B Series Ball Valves should be ordered with elastometric stem packing and seals or the optional live-loaded PTFE packing. This reduces the need for any further packing adjustment after receipt from the factory.
10
Pneumatic Actuators
How to Order Options
High Temperature Seals Add the suffix HT to the end of the part number for service up to 250 F (121 C). Add the suffix HT4 to the end of the part number for service up to 400 F (204 C). NOTE: The HT4 option is only available on series 62 and 63 90 models. Example: 2F-HB4LK-BN-SS-61AD-HT. Low Temperature Seals Add the suffix LT to the end of the part number. Example: 4A-MB4LPFA-SS-61SAC-LT. Accessories Add one of the following suffixes to the end of the part number. Example: 16F-SB16L-PF-T-SS-63AC-3-2D.
Suffix Single Option -1A -1B -1C -1D -1E -1F -1G -1H Double Option -2A -2B -2C -2D -2E -2F -2G -2H -2J -2K -2L -2M Triple Option -3A -3B -3C -3D -3E -3F Breather Block, Limit Switch, Solenoid Valve, (NEMA 4, 120 VAC) Breather Block, Limit Switch, Solenoid Valve, (NEMA 7, 120 VAC) Breather Block, Limit Switch, Solenoid Valve, (NEMA 4, 24 VDC) Breather Block, Limit Switch, Solenoid Valve, (NEMA 7, 24 VDC) Breather Block, Limit Switch, Solenoid Valve, (NEMA 4, 240 VAC) Breather Block, Limit Switch, Solenoid Valve, (NEMA 7, 240 VAC) Breather Block, Solenoid Valve, (NEMA 4, 120 VAC) Breather Block, Solenoid Valve, (NEMA 7, 120 VAC) Breather Block, Solenoid Valve, (NEMA 4, 24 VDC) Breather Block, Solenoid Valve, (NEMA 7, 24 VDC) Breather Block, Solenoid Valve, (NEMA 4, 240 VAC) Breather Block, Solenoid Valve, (NEMA 7, 240 VAC) Limit Switch, Solenoid Valve, (NEMA 4, 120 VAC) Limit Switch, Solenoid Valve, (NEMA 7, 120 VAC) Limit Switch, Solenoid Valve, (NEMA 4, 24 VDC) Limit Switch, Solenoid Valve, (NEMA 7, 24 VDC) Limit Switch, Solenoid Valve, (NEMA 4, 240 VAC) Limit Switch, Solenoid Valve, (NEMA 7, 240 VAC) Breather Block Solenoid Valve, (NEMA 4, 120 VAC) Solenoid Valve, (NEMA 7, 120 VAC) Solenoid Valve, (NEMA 4, 24 VDC) Solenoid Valve, (NEMA 7, 24 VDC) Solenoid Valve, (NEMA 4, 240 VAC) Solenoid Valve, (NEMA 7, 240 VAC) Limit Switch Two SPDT switches with mounting kit Accessory
Dual Mount Actuator Add DVM as a suffix to the end of the part number. Example: 6F-B6LPKC-SS-61AC-2-DVM. With DVM dual mount valve options, the following are standard arrangements: Two-way valves are provided in their failed position (in their closed position with AD actuators). Three-way valves are provided as shown below. Contact the factory for details on other available options.
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the Offer of Sale located in Catalog 4110-U Needle Valves (U Series).
11
Parker Hannifin Corporation Instrumentation Valve Division 2651 Alabama Highway 21 North Jacksonville, AL 36265-9681 USA Phone: (256) 435-2130 Fax: (256) 435-7718 www.parker.com/IVD Parker Hannifin plc Instrumentation Products Division Riverside Road Pottington Business Park Barnstaple, Devon EX31 1NP England Phone: +44 (0) 1271 313131 Fax: +44 (0) 1271 373636 Email: ipd@parker.com www.parker.com/IPD