TECHNICAL DATA SHEET (To Be Completed By the Tenderer)

ITEM No. 4: 11kV XLPE Power Cable


DESCRIPTION
1. Manufacturer and Country of Origin
2. Manufacturers type designation
3. Type
4. Applicable Standard
5. Voltage Raging
5.a. Suitable for maximum System Voltage
5.b. Voltage grade of this cable
5.c. Rated voltage between each conductor
and screen
5.d. Type of system Earthing
6. Conductor Material
6.1. No. of Core & Cross Section of Cable
6.2. Diameter of Conductor
6.3. Insulating Material / Thickness
6.4. Overall Jacket Material / Thickness
6.5. Overall Cable Diameter
7. Continuous Current
- In Ground at 20C
-In Air 30C
8. Electrical Parameter
-Resistance
-Reactance (XL)
9. ISO 9001 Certificate Submitted
10. Net Weight of the cable
11. Technical literature Submitted
12. Delivery of Equipment in months
following award of contract
(Allowing time for approval of drawing)

UNIT

NEA REQ 11Kv incomer

IEC

Sheet 1 of 1
DATA 11kV incomer

N2xHSYRaY
IEC 60502-2, IEC 60228

kV
kV
kV

12

12
6.0/10 (12)
6.0

No.Xmm 2
mm
mm
mm
mm

Solidly grounded
Copper
1x400
23.33

Solidly grounded
Stranded Annealed Copper
1x400
23.40
XLPE / 3.40
PVC / 2.60
48.60

Amp
Amp

702
833

ohm/km
W
Kg/m
YES/NO
Month

0.0470
0.1015

YES

YES
5.7
YES

___________________________________________________________________________________
Deviations from technical requirements:

___________________________________________________________________________________
Signed..................................................

As representative for.

Address................................................

Date...

TECHNICAL DATA SHEET (To Be Completed By the Tenderer)


ITEM No. 4: 11kV XLPE Power Cable
DESCRIPTION
1. Manufacturer and Country of Origin
2. Manufacturers type designation
3. Type
4. Applicable Standard
5. Voltage Raging
5.a. Suitable for maximum System Voltage
5.b. Voltage grade of this cable
5.c. Rated voltage between each conductor
and screen
5.d. Type of system Earthing
6. Conductor Material
6.1. No. of Core & Cross Section of Cable
6.2. Diameter of Conductor
6.3. Insulating Material / Thickness
6.4. Overall Jacket Material / Thickness
6.5. Overall Cable Diameter
7. Continuous Current
- In Ground at 20C
-In Air 30C
8. Electrical Parameter
-Resistance
-Reactance (XL)
9. ISO 9001 Certificate Submitted
10. Net Weight of the cable
11. Technical literature Submitted
12. Delivery of Equipment in months
following award of contract
(Allowing time for approval of drawing)

UNIT

NEA REQ 11Kv incomer

IEC

Sheet 1 of 1
DATA 11kV incomer

N2xHSYBaY
IEC 60502-2, IEC 60228

kV
kV
kV

12

12
6.0/10 (12)
6.0

No.Xmm 2
mm
mm
mm
mm

Solidly grounded
Copper
1x400
23.33

Solidly grounded
Stranded Annealed Copper
1x400
23.40
XLPE / 3.40
PVC / 2.50
44.30

Amp
Amp

702
833

ohm/km
W
Kg/m
YES/NO
Month

0.0470
0.1015

YES

YES
5.15
YES

___________________________________________________________________________________
Deviations from technical requirements:

___________________________________________________________________________________
Signed..................................................

As representative for.

Address................................................

Date...

TECHNICAL DATA SHEET (To Be Completed By the Tenderer)


ITEM No. 4: 11kV XLPE Power Cable
DESCRIPTION
1. Manufacturer and Country of Origin
2. Manufacturers type designation
3. Type
4. Applicable Standard
5. Voltage Raging
5.a. Suitable for maximum System Voltage
5.b. Voltage grade of this cable
5.c. Rated voltage between each conductor
and screen
5.d. Type of system Earthing
6. Conductor Material
6.1. No. of Core & Cross Section of Cable
6.2. Diameter of Conductor
6.3. Insulating Material / Thickness
6.4. Overall Jacket Material / Thickness
6.5. Overall Cable Diameter
7. Continuous Current
- In Ground at 20C
-In Air 30C
8. Electrical Parameter
-Resistance
-Reactance (XL)
9. ISO 9001 Certificate Submitted
10. Net Weight of the cable
11. Technical literature Submitted
12. Delivery of Equipment in months
following award of contract
(Allowing time for approval of drawing)

UNIT

NEA REQ 11Kv incomer

IEC

Sheet 1 of 1
DATA 11kV incomer

N2xHSYBY
IEC 60502-2, IEC 60228

kV
kV
kV

12

12
6.0/10 (12)
6.0

No.Xmm 2
mm
mm
mm
mm

Solidly grounded
Copper
1x400
23.33

Solidly grounded
Stranded Annealed Copper
1x400
23.40
XLPE / 3.40
PVC / 2.50
43.70

Amp
Amp

702
833

ohm/km
W
Kg/m
YES/NO
Month

0.0470
0.1015

YES

YES
5.30
YES

___________________________________________________________________________________
Deviations from technical requirements:

___________________________________________________________________________________
Signed..................................................

As representative for.

Address................................................

Date...

Potrebbero piacerti anche