WARNING: THE MAINS POWER HAS TO BE DISCONNECTED BEFORE ANY MEASUREMENTS ARE PERFORMED IN ACS600. WAIT AT LEAST 5 MINUTES FOR INTERMEDIATE CIRCUIT CAPACITORS TO DISCHARGE. The names of the Connectors of the Power Plate are presented in Figures 1 and 2
5
G13 E13 G12 E12
3
G11 E11
1
UPPER
6
G23 E23 T1 T T2 G22 E22
4
G21 E21
2
LOWER
P3
P2
P1
+
E13 G13 E12 G12 E11 G11
T2
P3
P2
P1
Figure 1. LPP
ABB Industry Oy
VSD Products, Medium AC Drives Dept. Date Prepared
hint7.doc
Revision
Page
TJX
22.05.97
Ere Jskelinen
Kjell Ingman
2/4
5
G13 E 13 G1 2 E 12
3
G 11 E 11
1
UP P E R
6
G 23 E 23 T1 T T2 G22 E 22
4
G 21 E 21
2
L OW E R
P3
P2
P1
T1 G23 E 23
G22
E22
G21
E21
+ -
E13 T2
G 13
E12
G12
E 11
G 11
P3
P2
P1
Figure 2. MPP
ABB Industry Oy
VSD Products, Medium AC Drives Dept. Date Prepared
hint7.doc
Revision
Page
TJX
22.05.97
Ere Jskelinen
Kjell Ingman
3/4
7.1 Measuring the collector-emitter resistance of the IGBT Measurement is done with the multimeter in the diode selection. Plus-probe + + + P1 P2 P3 Minus-probe P1 P2 P3 Display OL OL OL OL OL OL
7.2 Measuring the diode of the IGBT Measurement is done with the multimeter in the diode selection. Plus-probe P1 P2 P3 Minus-probe + + + P1 P2 P3 Display 0.35V 0.35V 0.35V 0.35V 0.35V 0.35V
7.3 Measuring the gate of the IGBT Measurement is done with the multimeter in the resistance selection. Plus-probe G11 G21 G12 G22 G13 G23 Minus-probe E11 E21 E12 E22 E31 E23 Display OL (loading capacitance) OL (loading capacitance) OL (loading capacitance) OL (loading capacitance) OL (loading capacitance) OL (loading capacitance)
ABB Industry Oy
VSD Products, Medium AC Drives Dept. Date Prepared
hint7.doc
Revision
Page
TJX
22.05.97
Ere Jskelinen
Kjell Ingman
4/4
7.4 Measuring the thermistor of the Power Plate Measurement is done with the multimeter in the resistance selection. Plus-probe T1 Minus-probe T2 Display 10 k (+/-10%)
Measurement has to be done when the Power Plate module is at room temperature.
7.5 Measurements against frame Measurement is done with the multimeter in the resistance selection. Plus-probe T1 T2 auxiliary + auxiliary P1 P2 P3 Minus-probe frame frame frame frame frame frame frame Display OL OL OL OL OL OL OL
7.6 Measuring the emitter of the IGBT Measurement is done with the multimeter in the resistance selection. Plus-probe E11 E12 E13 E21 E22 E23 Minus-probe P1 P2 P3 Display 0 0 0 0 0 0