Sei sulla pagina 1di 7

Systemair A/S - Air handling unit design SystemairCAD - Version C2012-07.03.

B9
Project: Unit: Danvent DV 40

18.07.2012 Page 1

Summary for unit no. 1


Unit size Unit width Weight 40 1720 1620 mm kg

Supply Airflow (1,205 kg/m) Face velocity (unit) External pressure Filter Fan Motor 6876.00 1.50 300 F7 79.3 690 1507 2.20 3x400 4.60 m3/h m/s Pa % Pa RPM kW V A

Extract 6876.00 1.50 300 F7 79.8 557 1400 2.20 3x400 4.60 kW/(m/s) kW/(m/s) m3/h m/s Pa % Pa RPM kW V A

SFP, clean filters including frequency converter 1.73 SFP, clean filters excluding frequency converter 1.64 Heat recovery Heating Pipe connections Cooling Pipe connections

57.4 % 38.32 kW - Air 9.3/26.0C - Water 70/55C - 14.7 kPa - 0.63 l/s 1 1/4" / 1 1/4" 181.85 kW - Air 41.0/14.1C - Water 7/12C - 24.4 kPa - 8.58 l/s 3" / 3"

Sound power level Supply air Outdoor air Exhaust air Extract air Sound break out

63 70 58 69 60 58

125 250 500 81 69 80 71 68 80 68 78 69 56 79 61 78 62 47

1k 78 52 76 55 43

2k 73 44 71 50 40

4k 69 38 68 46 37

8k 65 29 64 39 33

Hz dB dB dB dB dB

Total 82 63 80 64 54 dB(A) dB(A) dB(A) dB(A) dB(A)

Systemair Ltd. Sti.

Telephone : +90 2164895325 Telefax : +90 2164895327 www.systemair.com.tr mailbox@systemair.com.tr

Systemair A/S - Air handling unit design SystemairCAD - Version C2012-07.03.B9


Project: Unit: Danvent DV 40

18.07.2012 Page 2

Plan view

Access side

Systemair Ltd. Sti.

Telephone : +90 2164895325 Telefax : +90 2164895327 www.systemair.com.tr mailbox@systemair.com.tr

Systemair A/S - Air handling unit design SystemairCAD - Version C2012-07.03.B9


Project: Unit: Danvent DV 40

18.07.2012 Page 3

Right end

Left end

Systemair Ltd. Sti.

Telephone : +90 2164895325 Telefax : +90 2164895327 www.systemair.com.tr mailbox@systemair.com.tr

Systemair A/S - Air handling unit design SystemairCAD - Version C2012-07.03.B9


Project: Unit: Danvent DV 40

18.07.2012 Page 4

Technical specification The supply unit consist of


Mixing damper Supply Pressure drop Mixing damper type Damper blades Filter Dimensioning pressure drop Initial pressure drop/Final pressure drop Velocity, face area Velocity, filter area Filter class Filter size Filter length Inspection section Pressure drop Length Empty section Pressure drop Length Plate heat exchanger With face and by-pass damper Supply Air flow Pressure drop Air temperature in winter before/after Air relative humidity in winter before/after Condensate Capacity Temperature efficiency Dry efficiency according to EN 308 at 6876 m3/h Heat exchanger type Temperature efficiency Drip tray Heating coil, Fluid Air flow Pressure drop Air temperature before/after Capacity Face velocity
Systemair Ltd. Sti. Telephone : +90 2164895325 Telefax : +90 2164895327 www.systemair.com.tr mailbox@systemair.com.tr

Extract 7 3 dampers Standard Pa

118 59/177 1.75 0.10 F7 3x[490x742] 535

Pa Pa m/s m/s mm

1 150

Pa mm

1 300

Pa mm

Extract 6876 71 22.0/8.0 40/97 0.0 m3/h Pa C % l/min kW % %

WINTER

6876 71 -3.0/11.3 90/33 33.38 57.4 53.5

Aluminum heat exchanger Standard efficiency Standard

6876 9 9.3/26.0 38.32 1.75

m3/h Pa C kW m/s

Systemair A/S - Air handling unit design SystemairCAD - Version C2012-07.03.B9


Project: Unit: Danvent DV 40

18.07.2012 Page 5

Fluid type Fluid temperature inlet/outlet Fluid flow rate Fluid pressure drop Fluid velocity Coil volume Connection side Connection size inlet/outlet Tube material Fin material Fin spacing No. of rows Coil code

Water 70.0/55.0 0.63 14.7 1.08 5.4 Service side 1 1/4" / 1 1/4" Cu Al 2.1 1 DVH-40-W-Z-1-8-750-1455-2.1-CU-Al-H-1 1/4

C l/s kPa m/s l

mm

Cooling coil, Fluid Air flow 6876 Pressure drop air, wet coil with condensate droplets 110 Air temperature before/after 41.0/14.1 Air relative humidity before/after 60/100 Total cooling capacity 181.85 Sensible heat ratio 34 Face velocity 1.89 Condensate 2.7 Fluid type Water Fluid temperature inlet/outlet 7.0/12.0 Fluid flow rate 8.58 Fluid pressure drop 24.4 Fluid velocity 1.97 Coil volume 28.6 Connection side Service side Connection size inlet/outlet 3" / 3" Tube material Cu Fin material Al Fin spacing 2.0 No. of rows 6 Drip tray material Standard Coil code DVK-40-W-Y-6-25-720-1400-2.0-CU-Al-H-3 Droplet eliminator 14 Fan , Plug Direct drive Impeller type K-factor (p=1,2 kg/m3) Air flow Pressure drop Fan static pressure External pressure Total pressure Fan speed Fan efficiency Absorbed power Maximum fan speed Operation frequency Max. operating frequency M-ER50Cpro 252 6876 20 653 300 690 1507 79.3 1.66 1570 52 54

m3/h Pa C % kW % m/s l/min C l/s kPa m/s l

mm

Pa

m3/h Pa Pa Pa Pa RPM % kW RPM Hz Hz

Systemair Ltd. Sti.

Telephone : +90 2164895325 Telefax : +90 2164895327 www.systemair.com.tr mailbox@systemair.com.tr

Systemair A/S - Air handling unit design SystemairCAD - Version C2012-07.03.B9


Project: Unit: Danvent DV 40

18.07.2012 Page 6

Motor Motor type IE2 IEC-size M3AA 100LC Motor protection Thermistor Rated power 2.20 Speed (nominal) 1450 Current, Amp. 4.60 Efficiency 86.4 Voltage 3x400 Consumed power from mains power supply, excluding frequency converter 1.93 Consumed power from mains power supply, including frequency converter 2.03

kW RPM A % V kW kW

The extract unit consist of


Inspection section Pressure drop Length Filter Dimensioning pressure drop Initial pressure drop/Final pressure drop Velocity, face area Velocity, filter area Filter class Filter size Filter length Empty section Pressure drop Length Plate heat exchanger Data are stated on supply. Fan , Plug Direct drive Impeller type K-factor (p=1,2 kg/m3) Air flow Pressure drop Fan static pressure External pressure Total pressure Fan speed Fan efficiency Absorbed power Maximum fan speed Operation frequency Max. operating frequency M-ER50Cpro 252 6876 20 520 300 557 1400 79.8 1.33 1570 48 54 118 59/177 1.75 0.10 F7 3x[490x742] 535 Pa Pa m/s m/s mm 1 300 Pa mm

1 900

Pa mm

m3/h Pa Pa Pa Pa RPM % kW RPM Hz Hz

Systemair Ltd. Sti.

Telephone : +90 2164895325 Telefax : +90 2164895327 www.systemair.com.tr mailbox@systemair.com.tr

Systemair A/S - Air handling unit design SystemairCAD - Version C2012-07.03.B9


Project: Unit: Danvent DV 40

18.07.2012 Page 7

Motor Motor type IE2 IEC-size M3AA 100LC Motor protection Thermistor Rated power 2.20 Speed (nominal) 1450 Current, Amp. 4.60 Efficiency 86.4 Voltage 3x400 Consumed power from mains power supply, excluding frequency converter 1.54 Consumed power from mains power supply, including frequency converter 1.62 Mixing damper Supply Pressure drop Mixing damper type Damper blades 7 Extract 7 3 dampers Standard Pa

kW RPM A % V kW kW

Other parts
Sections Product CS-40-0-820-1-5 CS-40-0-1120-1-2 CS-40-0-1720-1-2 CS-40-0-1870-1-2 Feet Product Dimensions (width x height x length) Weight 2 kg 14 kg 14 kg 14 kg DVZ-40-1 1720 x 100 x 820 mm DVZ-40-2 1720 x 100 x 1120 mm DVZ-40-2 1720 x 100 x 1720 mm DVZ-40-2 1720 x 100 x 1870 mm Feets are supplied mounted on the unit casing. Duct connections Product Outdoor Supply Extract Exhaust Dimensions (width x height) 1650x750 mm 1650x750 mm 1650x750 mm 1650x750 mm Dimensions (width x height x length) 1720 x 1720 x 820 mm 1720 x 1720 x 1120 mm 1720 x 1720 x 1720 mm 1720 x 1720 x 1870 mm Weight 147 kg 324 kg 524 kg 582 kg

Systemair Ltd. Sti.

Telephone : +90 2164895325 Telefax : +90 2164895327 www.systemair.com.tr mailbox@systemair.com.tr