Sei sulla pagina 1di 6

07 21 00/JOH BuyLine 2048

Build sustainably with JM commercial insulation.


Improves the indoor air quality in your building. Johns Manville offers the most complete line of building insulations that improve indoor air quality because its made without formaldehyde. For more information, visit specJM.com. Makes your structure more sustainable because of high recycled content. JM commercial insulations are made with an average of 25 percent recycled glassincluding at least 20 percent certied post-consumer recycled bottle glass and the balance post-industrial recycled glass. For more information, visit specJM.com. Contributes toward a variety of LEED credits. Energy and Atmosphere Superior thermal performance. Materials and Resources 25 percent recycled glass, manufacturing plants across the United States and Canada. Indoor Environmental Quality A logical way to improve indoor air quality is to use JM Formaldehyde-free insulation. Innovation and Design Process We have ideas to help your buildings earn additional credits using a Comprehensive Formaldehyde Reduction Plan or Acoustic Comfort/Noise Pollution Reduction Plan. For more information, visit specJM.com.

Commercial Insulation Product Guide

Icon Key Thermal Acoustical Fire Resistance Moisture Control Formaldehyde-free


Products for improved indoor air quality

Visit specJM.com for more information on how JM Formaldehyde-free fiber glass insulation can improve indoor air quality.

Climate Pro Loose Fill Insulation

Unfaced Batts

ComfortTherm Plastic-wrapped Batts

DESCRIPTION

Blow-in, loose- ll ber glass insulation designed for attics and hard-to-reach locations. It is noncorrosive and noncombustible. Climate Pro insulation is for professionals using large truck-mounted, high-volume production blowing wool machines and for use in the Blow-In-Blanket System for enclosed cavities. Climate Pro BIBS insulation is loose- ll blown in behind netting for a custom t by certied BIBS installers. Average 25% recycled content.
R-VALUE/RSI
BLOWN-IN INSULATION R - 60/RSI-10.6 R - 49/RSI-8.6 R - 44/RSI-7.7 R - 38/RSI-6.7 R - 30/RSI-5.3 R -26/RSI-4.6 R -22/RSI-3.9 R -19/RSI-3.3 R -13/RSI-2.3 R -11/RSI-1.9

Light-density unfaced batts for installation within wall cavities, oors and ceilings. Available for metal or wood framing. May be used with a separate vapor retarder when moisture control is required. Highperformance cathedral ceiling batts also available. Available in R-values ranging from R-11 to R-38. Average 25% recycled content.

Poly-encapsulated batts designed for various concealed exterior and interior metal- or wood-framed cavities and directly above suspended ceilings. For wall applications, the vapor retarder is placed on the ange side while the remaining sides are perforated for moisture ow. For underoor applications, the vapor retarder is placed on the side opposite the stapling ange side for proper contact with the suboor. Average 25% recycled content.

AVA IL A BIL I T Y

MINIMUM INSTALLED THICKNESS

R-VALUE/RSI

THICKNESS

WIDTH

R-VALUE/RSI

THICKNESS

WIDTH

FOR METAL FRAMING R- 30/RSI-5.3 10 1/4" (260 mm) 22.8" (579 mm) 19.1" (485 mm) 17.4" (442 mm) 15.3" (389 mm) 12.4" (315 mm) 10.9" (277 mm) 9.3" (236 mm) 8.1" (206 mm) 5.7" (145 mm) 4.9" (124 mm) R-19/RSI-3.3 R-13/RSI-2.3 R-11/RSI-1.9 N/A* 6 1/2" (165 mm) 3 1/2" (89 mm) 3 5/8" (92 mm) 2 3/4" (70 mm)

16" (406 mm) 19" (483 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 15" (381 mm) 19" (483 mm) 23" (584 mm) 15" (381 mm) 15" (381 mm) 23" (584 mm) 15" (381 mm) 19" (483 mm) 23" (584 mm) 15" (381 mm) 23" (584 mm) 15" (381 mm) 23" (584 mm) 15" (381 mm) 19" (483 mm) 23" (584 mm)

FOR METAL FRAMING R - 30/RSI - 5.3 10 1/4" (260 mm) R -19/RSI - 3.3 R -13/RSI -2.3 R -11/RSI -1.9 6 1/2" (165 mm) 3 1/2" (89 mm) 3 5/8" (92 mm)

16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 16" (406 mm) 24" (610 mm)

FOR ABOVE SUSPENDED CEILINGS R -19/RSI - 3.3 6 1/2" (165 mm) 24" (610 mm) FOR WOOD FRAMING R - 30/RSI - 5.3* 10 1/4" (260 mm) R -25/RSI - 4.4* R -21/RSI - 3.7 R -19/RSI - 3.3* R -13/RSI -2.3* R -11/RSI -1.9* 8 1/2" (216 mm) 5 1/2" (140 mm) 6 1/2" (165 mm) 3 1/2" (89 mm) 3 1/2" (89 mm) 16" (406 mm) 24" (610 mm) 15" (381 mm) 23" (584 mm) 15" (381 mm) 15" (381 mm) 23" (584 mm) 15" (381 mm) 15" (381 mm) 23" (584 mm)

FOR WOOD FRAMING R-38/RSI-6.7** 13" (330 mm) R-30/RSI-5.3** R-25/RSI-4.4 R-22/RSI-3.9 R-21/RSI-3.7 R-19/RSI-3.3 R-15/RSI-2.6 R-13/RSI-2.3 R-11/RSI-1.9 10 1/4" (260 mm) 8 1/2" (216 mm) 7 1/2" (191 mm) 5 1/2" (140 mm) 6 1/2" (165 mm) 3 1/2" (89 mm) 3 1/2" (89 mm) 3 1/2" (89 mm)

FOR UNDERFLOOR WOOD FRAMING R -19/RSI - 3.3 6 1/2" (165 mm) 15" (381 mm)

*Sound control for interior walls

SPECIF ICAT ION COMPLIANCE

**Also available thinner for cathedral ceilings

*Also available with a facing that does not act as a vapor retarder

ASTM C 764: Type I Surface Burning Characteristics (ASTM E 84 and CAN/ULC S102.2): Flame Spread 25 or less Smoke Developed 50 or less Critical Radiant Flux (ASTM E 970): Greater than 0.12 W/cm (0.11 Btu/fts) Combustion Characteristics (ASTM E 136): pass Water Vapor Sorption (ASTM C 1104): 5% or less by weight Odor Emission (ASTM C 1304): pass Corrosiveness (ASTM C 764): pass Fungi Resistance (ASTM C 1338): pass Fungi Resistance (ASTM G 21): pass VOC Emissions (ES Section 01350): pass

ASTM C 665: Type I Surface Burning Characteristics (ASTM E 84): Flame Spread 25 or less Smoke Developed 50 or less Critical Radiant Flux (ASTM E 970): Greater than 0.12 W/cm (0.11 Btu/fts) Water Vapor Sorption (ASTM C 1104): 5% or less by weight Odor Emission (ASTM C 1304): pass Corrosiveness (ASTM C 665, 13.8): pass Fungi Resistance (ASTM C 1338): pass

ASTM C 665: Type II, Class A, Category 1 (R-25 is Category 2; not classied as a vapor retarder) Surface Burning Characteristics (ASTM E 84): Flame Spread 25 or less Smoke Developed 50 or less Critical Radiant Flux (ASTM E 970): Greater than 0.12 W/cm (0.11 Btu/fts) Water Vapor Permeance (ASTM E 96): Facing: 0.5 Perm (29 ng/Pasm2) Backing: 25 Perms (1400 ng/Pasm2) Water Vapor Sorption (ASTM C 1104): 5% or less by weight Odor Emission (ASTM C 1304): pass Corrosiveness (ASTM C 665, 13.8): pass Fungi Resistance (ASTM C 1338): pass

MR Faced Batts

Kraft- & Foil-Faced Batts

FSK-25 Faced Batts

DESCRIPTION

Johns Manville MR Faced insulation resists the growth of mold and mildew. The facing has been treated with a U.S. EPA-registered agent to help protect the facing from the potential growth of mold and mildew. Both the ber glass insulation and the facing pass the standard industry fungi resistance test (ASTM C 1338). The facing also passes the more stringent fungi test (ASTM D 2020) for paper and paperboard. Average 25% recycled content.

Light-density batts faced with foil or kraft facings for metal framing. Kraft-Faced batts are also available for wood-framed construction. Kraft- and Foil-Faced batts should be used in concealed applications. Foil facings provide excellent vapor retarders. Average 25% recycled content.

Light-density batts faced with FSK-25 for metal or wood framing. FSK-25 facings provide excellent vapor retarders. FSK-25 faced batts are for exposed applications. Average 25% recycled content.

AVA IL A BIL I T Y

R-VALUE/RSI

THICKNESS

WIDTH

R-VALUE/RSI

THICKNESS

WIDTH

R-VALUE/RSI

THICKNESS

WIDTH

FOR METAL FRAMING R - 30/RSI - 5.3 10 1/4" (260 mm) R -19/RSI - 3.3 R -11/ RSI -1.9 6 1/2" (165 mm) 3 5/8" (92 mm)

16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 16" (406 mm) 24" (610 mm) 15" (381 mm) 19 1/4" (489 mm) 23" (584 mm) 15" (381 mm) 15" (381 mm)

FOR WOOD FRAMING R - 30/RSI - 5.3 10 1/4" (260 mm) R -19/RSI - 3.3 R -15/RSI -2.6 R -13/RSI -2.3 6 1/2" (165 mm)

FOR METAL FRAMING KRAFT FACED R - 30/RSI - 5.3 10 1/4" (260 mm) 16" (406 mm) 24" (610 mm) 6 1/2" (165 mm) 16" (406 mm) R -19/RSI - 3.3 24" (610 mm) R -13/RSI -2.3 3 1/2" (89 mm) 16" (406 mm) 24" (610 mm) R -11/RSI -1.9 3 5/8" (92 mm) 16" (406 mm) 24" (610 mm) FOR METAL FRAMING FOIL FACED R - 30/RSI - 5.3 10 1/4" (260 mm) R -19/RSI - 3.3 R -13/RSI -2.3 R -11/RSI -1.9 6 1/2" (165 mm) 3 1/2" (89 mm) 3 5/8" (92 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm)

FOR METAL FRAMING R - 30/RSI - 5.3 10 1/4" (260 mm) R -19/RSI - 3.3 R -13/RSI -2.3 R -11/RSI -1.9 6 1/2" (165 mm) 3 1/2" (89 mm) 3 5/8" (92 mm)

16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 16" (406 mm) 24" (610 mm) 15" (381 mm) 23" (584 mm) 15" (381 mm)

FOR WOOD FRAMING R - 30/RSI - 5.3 10 1/4" (260 mm) R -19/RSI - 3.3 R -13/RSI -2.3 6 1/2" (165 mm) 3 1/2" (89 mm)

3 1/2" (89 mm) 3 1/2" (89 mm)

FOR WOOD FRAMING KRAFT FACED Available from R -11 (RSI -1.9) to R - 38 (RSI - 6.7) in various widths of 11" (279 mm), 12" (305 mm), 15" (381 mm), 16" (406 mm), 19" (483 mm), 23" (584 mm) and 24" (610 mm)

SPECIF ICAT ION COMPLIANCE

ASTM C 665: Kraft: Type II, Class C, Category 1 Kraft: not rated for Flame/Smoke Water Vapor Permeance (ASTM E 96): Kraft: 1.0 Perms (57 ng/Pasm) Water Vapor Sorption (ASTM C 1104): 5% or less by weight Odor Emission (ASTM C 1304): pass Corrosiveness (ASTM C 665, 13.8): pass Fungi Resistance (ASTM C 1338): pass Fungi Resistance (ASTM D 2020): pass

ASTM C 665: Foil: Type III, Class B, Category 1 Kraft: Type II, Class C, Category 1 Surface Burning Characteristics (ASTM E 84): Foil: Flame Spread 75 or less Smoke Developed 150 or less Kraft: not rated for Flame Spread/Smoke Developed Critical Radiant Flux (ASTM E 970): Foil: greater than 0.12 W/cm (0.11Btu/fts) Water Vapor Permeance (ASTM E 96): Foil: 0.05 Perms (3 ng/Pasm) Kraft: 1.0 Perms (57 ng/Pasm) Water Vapor Sorption (ASTM C 1104): 5% or less by weight Odor Emission (ASTM C 1304): pass Corrosiveness (ASTM C 665, 13.8): pass Fungi Resistance (ASTM C 1338): pass

ASTM C 665: Type III, Class A, Category 1 Surface Burning Characteristics (ASTM E 84): Flame Spread 25 or less Smoke Developed 50 or less Critical Radiant Flux (ASTM E 970): Greater than 0.12 W/cm (0.11Btu/fts) Water Vapor Permeance (ASTM E 96): 0.05 Perms (3 ng/Pasm) Water Vapor Sorption (ASTM C 1104): 5% or less by weight Odor Emission (ASTM C 1304): pass Corrosiveness (ASTM C 665, 13.8): pass Fungi Resistance (ASTM C 1338): pass

Panel Deck FSK-25 & PSK Faced Batts

Insul-SHIELD FSK-25, Unfaced & PSK Faced Board

Insul-SHIELD Coated Black Rolls

DESCRIPTION

FSK-25 or PSK* faced light-density batts with extended tabs for 2' x 4' (0.61 m x 1.22 m) panel deck roof applications. Ideal for applications where improved thermal performance and light reectivity drive the design process. FSK-25 and PSK facings provide excellent vapor retarders. Average 25% recycled content. *Polypropylene-scrim-kraft

FSK-25 or PSK* faced boards for curtain wall and other general commercial construction applications. Generally used where framing members are not present. FSK-25 and PSK facings provide excellent vapor retarders. Varied recycled content.

Durable black-coated surface laminated to face and edge of black ber glass blanket. For use in any application requiring excellent acoustical performance. Generally used where framing members are not present. Varied recycled content.

AVA IL A BIL I T Y

R-VALUE/RSI

THICKNESS

WIDTH

TYPE

THICKNESS

DENSITY

R-VALUE/RSI

TYPE
Roll

THICKNESS
1" (25 mm) 2" (51 mm)

R-VALUE/RSI
R - 4/RSI - 0.70 R - 8/RSI -1.41

NRC
0.70 1.00

FOR PANEL DECK WOOD ROOF FSK-25 R - 30/RSI - 5.3 10 1/4" (260 mm) 24" (610 mm) R -19/RSI - 3.3 6 1/2" (165 mm) 23" (584 mm)

PSK I/S 100 1 1/2" (38 mm) I/S 150 1" - 2 1/2" (25 mm-64 mm) I/S 225 1" - 2 1/2" (25 mm-64 mm)

1.0 pcf (16 kg/m) 1.50 pcf (24 kg/m) 2.25 pcf (36 kg/m)

R - 5.6/RSI - 0.99 Roll R- 4.2 through R-10.4/ RSI - 0.74 - RSI -1.83 R- 4.3 through R-10.9/ RSI - 0.76 - RSI -1.92 R- 4.3 through R-17.4/ RSI - 0.76 - RSI - 3.06 R- 4.3 through R-13.6/ RSI - 0.76 - RSI -2.40

FOR PANEL DECK WOOD ROOF PSK R -19/RSI - 3.3 6 1/4" (159 mm) 23" (584 mm)

I/S 300 1" - 4" 3.00 pcf (25 mm-102 mm) (48 kg/m) I/S 600 1" - 3" (25 mm-76 mm) FSK-25, UNFACED I/S 100 1 1/2" (38 mm) 1.0 pcf (16 kg/m) 6.00 pcf (96 kg/m)

R - 5.6/RSI - 0.99 R- 4.2 through R-16.7/ RSI-0.74 - RSI -2.94 R- 4.3 through R-17.4/ RSI - 0.76 - RSI - 3.06 R- 4.3 through R-17.4/ RSI - 0.76 - RSI - 3.06 R- 4.5 through R-13.6/ RSI - 0.79 - RSI -2.40

I/S 150 1" - 4" 1.50 pcf (25 mm-102 mm) (24 kg/m) I/S 225 1" - 4" 2.25 pcf (25 mm-102 mm) (36 kg/m) I/S 300 1" - 4" 3.00 pcf (25 mm-102 mm) (48 kg/m) I/S 600 1" - 3" (25 mm-76 mm) 6.00 pcf (96 kg/m)

SPECIF ICAT ION COMPLIANCE

ASTM C 665: FSK: Type III, Class A, Category 1 PSK: Type II, Class A, Category 1 Surface Burning Characteristics (ASTM E 84): FSK/PSK: Flame Spread 25 or less Smo Developed 50 or less ke Critical Radiant Flux (ASTM E 970): Greater than 0.12 W/cm (0.11Btu/fts) Water Vapor Permeance (ASTM E 96): FSK: 0.05 Perms (3 ng/Pa s m) PSK: 0.10 Perms (6 ng/Pa s m) Water Vapor Sorption (ASTM C 1104): 5% or less by weight Odor Emission (ASTM C 1304): pass Corrosiveness (ASTM C 665, 13.8): pass Fungi Resistance (ASTM C 1338): pass

ASTM C 612: PSK: Type II, Class A, Category 1 FSK: Type III, Class A, Category 1 Unfaced: Type IA, or Type IB (IS300,IS600) All: Surface Burning Characteristics (ASTM E 84): FSK/PSK: Flame Spread 25 or less Smoke Developed 50 or less Maximum Use Temperature (ASTM C 411): Unfaced: 350F (177C) Faced: 250F (121C) Combustion Characteristics (ASTM E 136): IS150, IS225, IS300: pass Water Vapor Permeance (ASTM E 96): PSK: 0.10 Perms (6 ng/Pa s m) FSK, Unfaced: 0.05 Perms (3 ng/Pa s m) Water Vapor Sorption (ASTM C 1104): 5% or less by weight Compressive Resistance (ASTM C 165): IS300, IS600: 25 psf (1.2 kPa) @10% Linear Shrinkage (ASTM C 356): none Odor Emission (ASTM C 1304): pass Corrosiveness (ASTM C 665, 13.8): pass Fungi Resistance (ASTM C 1338): pass

ASTM C 612: Type 1A, Category 1 Surface Burning Characteristics (ASTM E 84): Flame Spread 25 or less Smoke Developed 50 or less Maximum Use Temperature (ASTM C 411): 250F (121C) Water Vapor Sorption (ASTM C 1104): 5% or less by weight Linear Shrinkage (ASTM C 356): none Odor Emission (ASTM C 1304): pass Corrosiveness (ASTM C 665, 13.8): pass Fungi Resistance (ASTM C 1338): pass

The physical and chemical properties of the Commercial Insulation Products listed herein represent typical, average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. They are supplied as a technical service and are subject to change without notice. Numerical ame spread and smoke developed ratings are not intended to reect hazards presented by these or any other materials under actual re conditions. Check with the Regional Sales Ofce nearest you to assure current information. All Johns Manville products are sold subject to Johns Manvilles standard Terms and Conditions including Limited Warranty and Limitation of Remedy. For a copy of the Johns Manville standard Terms and Conditions, Limited Warranty and Limitation of Remedy, and information on other Johns Manville thermal insulations and systems, call (800) 654-3103.

Insulation Systems 717 17th St. Denver, CO 80202 (800) 654-3103 specJM.com
HIG-1224 Sweets 10-08 (Replaces 8-08) Copyright 2008 Johns Manville Printed in USA