Sei sulla pagina 1di 24

Aug.

2006

System Application
Applicable Temperature Range (degree C)

-60

-40
NH3/CO2 Cascade

-20

20

40

60

80

NH3 2 stage CO2 Brine NH3 Single CO2 Brine CO2 Heat Pump

- secondary medium -

CO2 Brine

CO2 Cooler

CO2 Pump

CO2 Cycle NH3 Machine

Exp. Valve

NH3 Cycle

Condenser
3

Ice maker plant NH3 / CO2 brine system


NH3 Evacon Unit
Screw Comp. N160L Brine cooler

Receiver

CO2 Pump

G.L

Ice making room


CaCl brine

135Kg/drum

Monitor

T
G.L

CO2 Herring borne coil

Ice maker plant


Machine Units
100kW Motor NH3100kg

CO24,000kg CO2 Tank & CO2 Pump


5

FD; Freezed Dry System

Control Panel

Vacumme

Screw Comp.

Steam

Evaporative Cond. Cond.

Vacumme Chamber
CO2 Cold Trap

CO2 Tnak

CO2 Pump

NH3 Package

FD; Freezed Dry System


CO2 CoolerCO2 Tank CO2 Pump

Vacuum Tank CO21400kg


NH3 TE-55-35

N1612LLC-LBL4500rpm1set NH3150kg
7

Freezer System
Control Panel

Hot Water
Evaporative Cond. Cond.

NH3 Compr. CO2 Tank

CO2 Cooler

CO2 Pump

NH3 Package

CO2 Type Freezer


8

Mesh Freezer
Model:EKCCU-37L NH325kg NH3 TE-30

500kg/hr1 CO400kg

Spiral Freezer

1.5ton/hrx2sets Spiral Freezer

EK-CCU150L-S

5sets

ModelN1612LSC63) NH3 : TE=-45, TCO2=-40

CO2 Tank2 CO2 Pump4 CO2 3,500kg


10

Typical Installation Kobe Central Cold Storage

CO2Brine-Air cooler

CO2 Cooler

Receiver

CO2 Pump

ECC EVACON unit

MONITORING

11

Typical Cold Storage


Multi-Purpose Cold Storage 7,000 ton

EK-CCU100L 2set N1610SLC-64 75kW NH360kg2 CO2 Tank&Pump Unit CO2700kg


12

NH3 / CO2 Cascade System


Air Cooler with CO2 CO2 Compr. Exp.Valve CO2 Cycle

NH3 Compr. Exp. Valve NH3 Cycle

NH3 Condenser
13

C.O.P. Comparison
3
NH3 2stg

2. 5 C O P

CO2/NH3 Cascade

1. 5

R-22 2stg

0. 5 -60 -50 -40 TE


14

-30

-20

Test Plant for NH3/CO2 Cascade System 3 2

CO2 Compr.

Fine Oil Separator CO2 Low Temp. Receiver NH3Copmr. Cascade Cond.

Oil Separator

Cold Strage NH3 Condenser

Cascade Unit CO2 Pump Cooling Tower

Air Cooler

15

Test Plant
for NH3/CO2 Cascade System
Cascade Cond. CO2 Compr. CO2 Low Temp. Receiver

NH3 Compr.

CO2 Pump
16

Freezer Application
Control Panel

Hot Water

Evaporative Cond.

NH3 Compr.

Cascade Cond.

Air Cooler

CO Compr.

NH3/CO2 Cascade Unit

Freezer
17

NH3 / CO2 Cascade Unit for the Freezer 3 2

Cascade Unit

High sideN160L 35/10 Low side C6HK 40 -10/CO2 Low Receiver Unit 18

C6HK

CO2

Compressor
Specifications
Model Bore x Stroke Number of Cylinder Head cover cooling Speed Drive method Swept volume(@1,450rpm) Capacity control Flange size (suc/dis) Net weight Design pressure (H/L) Max suction pressure Max discharge pressure Differential pressure (D-S) m3/h % mm kg bar bar bar bar rpm mm C6HK 85x65 6 Air cooled 900-1800 Direct 192.4 100,66,33 65/50 350 42/25 20 40 35 19

for CO2/NH3 Cascade System

CO2 Heat Pump


Hot Water Supply Unit

20

CO2 Heat Pump

CO2 Compr.

Inlet

Gas/Liquid

CO 2 Super critical CO 2 Liquid CO 2 Gas

Oil Oil Cooler


Inlet

Brine

Oil Separator Exp Hot Water Brine Cooler

Outlet

Inlet

Hot-water + Ice making


Hot water tank Ice Bank Outlet

21

CO2 Heat Pump

CO2 Heat Pump for Air Conditioning CO2 Heat Pump for Air Conditioning and Hot Water Supply System and Hot Water Supply System

I tem I m aki ce ng capaci ty H ot w ater capaci ty B rake P ow er D i ensi m on

P erform ance

C om bi ned H eati & C oolng ng i above 4. (at 3600rpm ) 0 W =2, 700m m , L =4, 900m m , L =3, 100m m
22

CO2 Heat Pump


Hot Water Supply Unit
Heating Model Motor COP Remarks

60kW

2HT4P

25kW4P

>3.0

Water 9

90

collecting supplying @55 Open

Hot water tank water Max Hot water pump

23

C2HT CO2

Compressor
Specifications
Model Bore x Stroke Number of Cylinder Head cover cooling Speed Motor (Semi-hermetic) Swept volume(@1,450rpm) Capacity control Flange size (suc/dis) Net weight Design pressure (H/L) Max suction pressure Max discharge pressure Differential pressure (D-S) rpm kW m3/h % mm kg bar bar bar bar mm C2HT 45x45 2 Air cooled 900-1,800 25 12.5 100 25/20 410 150/80 70 120 100 24

for CO2 Heat Pump System

Potrebbero piacerti anche