INTERNAL TENDONS
x
3 3 3 3
PRESTRESSING SYSTEM
(led inside the concrete structure) top straight tendons bottom straight tendons curved tendons inside webs horizontal straight tendons inside webs
EXTERNAL TENDONS
x
INTERNAL TENDONS
s s s s s s s
15 pc strand / tendon Dstrand = 0,6 (15,2 mm ) Astrand = 150 mm2 Type ST 1670/1860 N/mm2 Finit = 2973 kN / tendon Dout = 95 mm
x
corrugated sheathing
Anchorage system :
DYWIDAG SI (DSI) MA 6815 (Multiplane anchorage)
4
s s
Corrugated sheathing
Corrugated sheathing
Plastic trumpet
Grout cap
5
8 m/s
Strand in
Wedge plates
EXTERNAL TENDONS
s
( double-extruded )
4 X VT-CMM 04-150 D
3
band / tendon
s s s s
s
Dstrand = 0,6 (15,2 mm ) Astrand = 150 mm2 Type ST 1570/1770 N/mm2 Finit = 2973 kN / tendon
Anchorage system :
x VORSPANN
3
TECHNIK
8
EXTERNAL TENDONS
s
VT-CMM BAND
VT-CMM 04-150 D
VT-CMM 02-150 D
9
External tendon
Bottom deviator
Bottom deviator
10
Reels of bands
DEVIATORS
Trumpet seal for VT-CMM 4x04-150D tendons at the anchorage