Notices
The information in this document is subject to change without notice. While every effort has been made to ensure that all information in this document is accurate, the Authors accept no liability for any errors that may arise. No part of this document may be transmitted or copied in any form, or by any means, for any purpose, without the written permission of the Authors. Issue 4.0 January 30, 2009 Part No. 0090505-04A
Acknowledgments
All names, brands, products or services are trademarks or registered trademarks of their respective companies.
ii
Contents
Contents
Acknowledgments ................................................................................................................................................... ii Preface .................................................................................................................................................................... vii What is in this guide ............................................................................................................................................... vii Who should use this guide ...................................................................................................................................... vii Related Documentation........................................................................................................................................... vii Revision History .................................................................................................................................................... viii 1 Safety Guidelines .............................................................................................................................................. 1 1.1 Safe Handling ............................................................................................................................................... 1 1.2 Safety ............................................................................................................................................................ 2 1.3 Battery Safety ............................................................................................................................................... 4 1.4 Class 1 Laser Product .................................................................................................................................. 4 1.5 Rack System Precautions ............................................................................................................................. 5 1.6 Data Security ................................................................................................................................................ 5 1.7 Special Tools and Equipment ....................................................................................................................... 6 System Overview .............................................................................................................................................. 7 2.1 RS-1220-F4-5412E RAID Enclosure .......................................................................................................... 7 2.2 RS-1220-E3-XPN Expansion Enclosure ...................................................................................................... 8 2.3 Enclosure Chassis ......................................................................................................................................... 9 2.3.1 Enclosure Drive Slots ....................................................................................................................... 10 2.3.2 Operators Panel .............................................................................................................................. 10 2.3.3 Alarms(Audible and Visible) ............................................................................................................ 11 2.4 The Plug-in Modules .................................................................................................................................. 13 2.4.1 Power Supply Module ...................................................................................................................... 13 2.4.2 Cooling Fan Module ........................................................................................................................ 14 2.4.3 F5412E RAID Controller Module .................................................................................................... 16 2.4.4 Disk I/O Module ............................................................................................................................... 20 2.4.5 Drive Carrier Module ...................................................................................................................... 22 2.4.6 Blank Modules .................................................................................................................................. 26 Getting Started ................................................................................................................................................ 27 3.1 Introduction ................................................................................................................................................ 27 3.2 Planning Your Installation ......................................................................................................................... 27 3.2.1 Enclosure Drive Slot Numbering Convention .................................................................................. 29 3.3 Time-Out Issues ......................................................................................................................................... 29 3.4 Enclosure Installation Procedures .............................................................................................................. 30 3.4.1 Preparation of Site and Host Server ................................................................................................ 30 3.4.2 Unpacking the Enclosure System ..................................................................................................... 30 3.4.3 Rack Installation Pre-Requisites ...................................................................................................... 31 3.4.4 Rack Installation Procedure ............................................................................................................ 31 3.5 Module Removal & Installation ................................................................................................................. 35 3.5.1 Power Supply Module ...................................................................................................................... 35 3.5.2 Cooling Fan Module ........................................................................................................................ 36 3.5.3 RAID Controller Module ................................................................................................................. 38 3.5.4 Disk I/O Module ............................................................................................................................... 40 3.5.5 Drive Carrier Module ...................................................................................................................... 42 3.5.6 SFP Transceiver Installation ........................................................................................................... 45 3.6 Cabling the Enclosures ............................................................................................................................... 46
iii
3.7 Cabling Multiple Enclosures ..................................................................................................................... 3.8 Ethernet Connection .................................................................................................................................. 3.9 Drive Slot Arrangement ............................................................................................................................ 3.9.1 Drive Location Rules ....................................................................................................................... 3.9.2 Drive Start ....................................................................................................................................... 3.10 AC Power Cord Connection ...................................................................................................................... 3.11 Grounding Checks ..................................................................................................................................... 3.12 Management Interfaces ............................................................................................................................. 3.12.1 StorView Storage Management Software ........................................................................................ 3.12.2 RAID Configuration Utility ............................................................................................................. 4 Operation ........................................................................................................................................................ 4.1 Before You Begin ...................................................................................................................................... 4.2 Power On ................................................................................................................................................... 4.3 Starting the Drives ..................................................................................................................................... 4.3.1 Disk Drive LEDs ............................................................................................................................. 4.4 Starting Embedded StorView .................................................................................................................... 4.5 Embedded StorView Initial Setup ............................................................................................................. 4.5.1 Setting up the Embedded StorView Module: Microsoft Windows ................................................... 4.5.2 Setting up the Embedded StorView Module: Linux ......................................................................... 4.6 Power Down .............................................................................................................................................. Troubleshooting and Problem Solving ........................................................................................................ 5.1 Overview ................................................................................................................................................... 5.1.1 Troubleshooting using StorView ..................................................................................................... 5.1.2 Initial Start-up Problems ................................................................................................................. 5.2 Status Indicators (LEDs) ........................................................................................................................... 5.2.1 Power Supply Module LEDs ........................................................................................................... 5.2.2 Cooling Fan Module LED ............................................................................................................... 5.2.3 OPS Panel LEDs ............................................................................................................................. 5.2.4 RAID Controller Module LEDs ....................................................................................................... 5.2.5 Disk I/O Module LEDs .................................................................................................................... 5.2.6 Drive Status LEDs ........................................................................................................................... 5.2.7 SCSI Enclosure Services (SES) ....................................................................................................... 5.3 Audible Alarm ........................................................................................................................................... 5.3.1 Audible Alarm Mute ........................................................................................................................ 5.4 Troubleshooting ......................................................................................................................................... 5.4.1 OPS Panel System Faults ................................................................................................................ 5.4.2 OPS Panel Logical Faults ............................................................................................................... 5.4.3 Thermal Control .............................................................................................................................. 5.4.4 Thermal Alarm ................................................................................................................................ 5.4.5 Thermal Warnings ........................................................................................................................... 5.4.6 Firmware Updates ........................................................................................................................... Module Removal and Replacement .............................................................................................................. 6.1 Dealing with Hardware Faults ................................................................................................................... 6.2 Continuous Operation During Replacement ............................................................................................. 6.2.1 OPS Panel ....................................................................................................................................... 6.3 Replacing a Module ................................................................................................................................... 6.3.1 Power Supply Modules .................................................................................................................... 6.3.2 Cooling Fan Module .......................................................................................................................
49 49 50 50 50 51 52 53 53 53 55 55 55 56 56 57 57 58 60 61 63 63 63 63 65 65 65 66 68 69 69 70 71 71 72 72 73 73 74 74 75 77 77 78 78 79 79 81
iv
Contents
6.3.3 RAID Controller Module ................................................................................................................. 82 6.3.4 Disk I/O Module ............................................................................................................................... 85 6.3.5 Removal and Installation of the Blank Module ................................................................................ 87 6.3.6 Replacing a Battery Module ............................................................................................................ 88 6.3.7 Replacing SFP Transceivers ............................................................................................................ 89 6.3.8 Replacing a Drive Carrier Module .................................................................................................. 90 6.3.9 Engaging the Anti-tamper Locks ...................................................................................................... 94 6.3.10 Dummy Drive Carrier Module Replacement ................................................................................... 94 6.4 Replacement Parts and Ancillary Items ..................................................................................................... 95 A Technical Specifications ................................................................................................................................. 97 A.1 Dimensions ................................................................................................................................................. 97 A.2 Weight ........................................................................................................................................................ 97 A.3 AC Power (350W PSU) ............................................................................................................................. 98 A.4 Current Consumption ................................................................................................................................. 98 A.5 Environment ............................................................................................................................................... 98 A.6 F5412E RAID Controller Module Specification ....................................................................................... 99 A.7 Disk I/O Module Specification ................................................................................................................ 100 A.8 Drive Carrier Module Specification ......................................................................................................... 100 B Standards & Regulations ............................................................................................................................. 101 B.1 International Standards ............................................................................................................................. 101 B.2 Potential for Radio Frequency Interference ............................................................................................. 102 B.3 European Regulations .............................................................................................................................. 102 B.4 Power Supply Safety and EMC Compliance ........................................................................................... 102 B.5 AC Power Cords ...................................................................................................................................... 103 B.6 EMC Precautions ..................................................................................................................................... 103 B.7 ESD Precautions ....................................................................................................................................... 103 B.8 Recycling of Waste Electrical and Electronic Equipment (WEEE) ........................................................ 104 Index ...................................................................................................................................................................... 105
vi
Preface
Preface
What is in this guide
This user guide gives you step-by-step instructions on how to install, configure and connect the RS1220-F4-5412E RAID and RS-1220-E3-XPN storage solution to your host computer system, and how to use and maintain the system.
Related Documentation
RS-1220-F4-5412E & RS-1220-E3-XPN Quick Start Guide (P/N 0090506-04A) VT-100 RAID Configuration Utility User Guide (P/N 0095612-04A) StorView Storage Management Software Installation Guide (P/N 0094090-05A) StorView Storage Management Software RAID Module User Guide (P/N 0094089-05A) HBA PCI Card User Guide (appropriate manufacturers manual supplied with your system)
vii
Revision History
Version Date Description of Change
1.0 2.0
Initial Release Related document part numbers. Changes were related to rack installation illustrations, Controller LED table, Drive Status LEDs, and OPS LED table. Modified Drive Carrier LEDs table. Minor procedural changes. Related document part numbers. Changes include a new power supply module that affected a large percentage of the illustrations, revised PSU caution label, clarification of the term earth, updated notes and procedures, more details on A/A and A/P MUX Transition cards, and notations for which components are hot swappable. Changes affected the Driver Carrier LED descriptions. Related document part numbers.
3.0
June, 2008
4.0
January, 2009
viii
Safety Guidelines
Chapter 1
Safety Guidelines
1.1 Safe Handling
Caution If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
In order to comply with applicable safety, emission and thermal requirements, no covers should be removed and all bays must be populated with plug-inmodules. The system must not be run without all modules in place. Permanently unplug the enclosure before you move it, or if you think that is has become damaged in any way.
Warning
An RS-1220 enclosure can weigh up to 32 kg (70.4 lb.). Do not try to lift it by yourself.
Do not lift the enclosure by the handles on the power supplies, as they are not designed to support that weight.
Figure 11
1.2 Safety
RS-1220 enclosures must only be operated from a power supply input voltage range of 100-240 V, 50-60 Hz.
Figure 12
The plugs on the power supply cord are used as the main disconnect device. Ensure that the socket outlets are located near the equipment and are easily accessible. The wiring installation must provide a disconnect device close to the equipment. The equipment must be operated with two working power supply modules.
Figure 13
Figure 14
To prevent overheating, do not operate the enclosure with one power supply removed for more than 30 minutes. When powered by multiple AC sources, disconnect all source power for complete isolation.
Safety Guidelines
Figure 15
The power connection should always be disconnected prior to removal of the power supply module from the enclosure. A safe electrical ground (earth) connection must be provided to the power cords. Check the grounding of the enclosure before applying power. Provide a suitable power source with electrical overload protection to meet the requirements listed in the technical specification.
Warning
Do not the remove covers from the Power Supply module. Danger of electric shock inside. Return the power supply module to your supplier for repair.
Figure 16
Unplug the enclosure if you think that it has become damaged in any way and before you move it. An RS-1220 enclosure can weigh up to 32 kg (70.4 lb.). Do not try to lift it by yourself. Do not lift an RS-1220 enclosure by the handles of the Power Supply modules. They are not designed to support the weight of the enclosure. In order to comply with applicable safety, emission and thermal requirements, no covers should be removed and all bays must have the correct plug-in modules installed.
Figure 17
Do not operate with any drive carrier modules missing. Drive spin down time is approximately 30 seconds. Allow the drives to spin down before removing them.
Figure 18
Figure 19
Safety Guidelines
System Overview
Chapter 2
System Overview
2.1 RS-1220-F4-5412E RAID Enclosure
The RS-1220-F4-5412E RAID enclosure is a 2U (rack space) disk drive enclosure, housing twelve low profile (1 inch high), 3.5 inch form factor SATA or SAS disk drives and up to two FC-SAS RAID Controllers.
Figure 21
The front of the enclosure contains 12 drive slots, each of which accommodates a plug-in Drive Carrier module. There is also an operators panel that provides status LEDs and an alarm silence button.
At the rear, the RS-1220 chassis assembly contains five plug-in module bays that house the two Power Supply modules, a Cooling Fan module and two F5412E RAID Controller modules.
Figure 22
Figure 23
System Overview
please refer to section 2.4.5.4 on page 25. Two plug-in Power Supply modules: 100-240V AC, 350W (See Figure 26). One plug-in Cooling Fan module (See Figure 28). Two plug-in RAID Controller modules. All RAID Controller modules incorporate the StorView Storage Management Embedded module.
Note: If only one RAID Controller module is installed, then a Blank module must be installed in
the unused bay. The RAID Controller module should be installed in Bay 0 and the blank in Bay 1 (where Bay 0 is the lower and Bay 1 is the upper bay, see Figure 22). The chassis is fitted with 19 inch Rack mounting features which enable it to be fitted to standard 19 inch racks and uses 2 EIA units of rack space (i.e. 3.5" high). The RS-1220-E3-XPN expansion enclosure as supplied consists of: Chassis and backplane with integral (front panel mounted) OPS panel (See Figure 25). Up to twelve (12) Drive Carrier modules (See Figure 216), using either SAS or SATA disk drives.
Note: Dummy Carriers modules must be installed in all unused drive slots to maintain airflow,
please refer to section 2.4.5.4 on page 25. Two plug-in Power Supply modules:100-240V AC, 350W (See Figure 26). One plug-in Cooling Fan module (see Figure 28). Two Disk I/O modules (see Figure 216).
Note: If only one Disk I/O module is installed then a Blank module must be installed in the unused
bay. The Disk I/O module should be installed in Bay 0 and the blank in Bay 1 (Figure 23). The chassis is fitted with 19 inch Rack mounting features which enable it to be fitted to standard 19 inch racks and uses 2 EIA units of rack space (i.e. 3.5" high).
Figure 24
The OPS panel is an integral part of the enclosure assembly and can only be replaced with a replacement enclosure. Enclosure replacement should only be performed by trained personnel.
Figure 25
OPS Panel
Pressing the Alarm Mute button when no error or critical conditions are occurring will start an LED selftest. Pressing the button again will stop the self-test, or if an error condition occurs while the self-test is on-going the test will terminate.
Note
When performing a self test, the RAID enclosure requires pressing and holding the mute button for 4 seconds before the test begins, and to stop the test holding the button for approximately 2 seconds. The Expansion enclosure will enter the self test mode by pressing the button momentarily and similarly touching the button momentarily will stop the test. During the self-test you will initially hear two beeps followed by illumination of the System Fault, Logical Fault, and Box Identify LEDs. The Drive Carrier lower Fault LEDs (amber) will flash continuously during the test.
10
System Overview
ON ON ON ON
OFF ON OFF ON
OFF ON X X
Aux present, overall power failed or switched off. OPS Panel power on (5s) test state Power On, all functions good PSU Fault LED or Any PSU Fault or Fan Fault Cooling Module Over or Under temperature Fault LED RAID Controller Fault LED on lower controller RAID Controller Fault LED on upper controller RAID Controller Fault LED ESI processor/RAID Controller 0 failed ESI processor/RAID Controller 1 failed Unknown (invalid or mixed) module type installed, or 12C Bus Failure (inter ESI processor).
ON
ON
ON
ON
ON
FLASHING X
ON ON ON
FLASHING X X X OFF ON
X X X
PSU Removed:
PSU removed when two were present at Start of Day Power On, all functions good
Drive failure has occurred causing loss of availability or redundancy. Arrays performing background function SES controlled enclosure identify.
ON X
Note
X X
FLASHING X X ON
11
RS-1220 enclosures include an Audible Alarm which indicates when a fault state is present. The following conditions will activate the Audible Alarm: Fan Fault or Failure (single or dual) Voltage Out Of Range Over Temperature Thermal Overrun System Fault Logical Fault Power Supply Fault Removal Of One Power Supply module When the audible alarm sounds, it may be muted by pressing the Alarm Mute push-button which is incorporated in the enclosure front panel. The alarm can also be muted or disabled from the StorView Storage Management software Main page. Refer to the StorView Storage Management software user guide for details. Some critical error conditions such as: enclosure temperature exceeded upper limit, more than one fan failure, and controller temperature failure, the alarm will sound continuously. You cannot mute these alarms. For some conditions that are not as critical will provide an intermittent alarm. These conditions would include: component removed, temperature increasing, array drive member faults, etc. The alarms under these conditions can be muted.
12
System Overview
Two 100 - 240V 350W power supply modules are installed at the rear of the enclosure as part of the core product. The power supply provides an N+1 redundant configuration. If one power supply fails, the system will continue to operate normally on the remaining supply, until the failed module is replaced. They feature an ON/OFF switch so that the power supply can be shut down without having to remove the power cable.
Figure 26
Power supply voltage operating ranges are nominally 115V or 230V, selected automatically.
13
Note
When inserting a power supply module into a operating enclosure with data I/O in progress, smoothly insert the module into the open bay and secure the latch. Harshly inserting the module could possibly cause drives to temporarily go offline which could affect ongoing data I/O operations.
Fault LED
Power On LED
Figure 27
Two LEDs mounted on the rear panel of the power supply module (see Figure 26) indicate the status of the module. The table below describes the LEDs and the meaning of each. Table 22 Power Supply LEDs
Fault LED (Amber) Status Power On LED (Green)
OFF OFF
OFF ON
No AC power source is being supplied to either power supply. No AC power source is being supplied to this power supply. OR The power cord is attached to the power source, but the power supply switch is in the OFF position. OR Power supply fault is occurring such as over-temperature warning, over-voltage warning, over-current warning, or a power supply fan has failed.
ON
OFF
2.4.1.1
14
System Overview
Note
During the power up sequence, the Cooling Fan Module Fault LED will be illuminated until the RAID Controllers have completed their boot up cycle. This also applies to the expansion enclosure except in this case the Disk I/O modules must complete their boot cycle before the LED is extinguished. The system must be operated with low pressure rear exhaust installation (back pressure created by rack doors and obstacles not to exceed 5 pascals (0.5mm water gauge)).
Note
Figure 28
The Cooling Fan module incorporates an amber Fault LED. The states are described below. Table 23 Cooling Fan Module Fault LED
Status
OFF ON
Fan OK. One or more fans have failed. OR The RAID Controller or Disk I/O module has not completed the boot sequence.
Figure 29
15
The plug-in F5412E RAID Controller modules have been designed for integration into a RS-1220 enclosure. The controller provides an external fibre channel (FC) cable interfacing for the host computer system, SAS interfacing for the expansion enclosure, an out-of-band Ethernet interfacing for Embedded StorView, and an out-of-band VT-100 interfacing for the controller firmware program. The RAID Controller is hot swappable. The controllers internal processor monitors conditions on each disk drive port. It provides an enclosure management interface to devices on the backplane, power supplies, cooling fan module, partner RAID Controller module, and OPS panel that monitors internal functions. When the enclosure is supplied with dual controllers, these processors operate in an active-active configuration to allow failover and failback. The F5412E RAID Controller uses the latest technology providing support for Native Command Queuing (NCQ). NCQ provides an increase in performance of SATA disk drives by allowing the individual disk to internally optimize the order in which received read and write commands are executed. This can reduce the amount of unnecessary going back-and-forth of the drive's heads, resulting in increased performance. The controllers also support a set of performance tuning features like writeback cache management, overload performance management, synchronized cache flush, target command thread balancing and sequential write optimization. Description and use of these performance features are found in the StorView Storage Management Software User Guide and in the RAID Configuration Utility User Guide. The controller supports either 512 MB or 1024 MB (1 GB) cache memory sizes. The module incorporates LED indicators, shown in Figure 211 and see Table 24 on page 18 for details of the LED status conditions. The F5412E RAID Controller module has the following external ports. Two external fiber channel Host ports that allow for fitting of Small Form-Factor Pluggable (SFP) modules, with auto-bypass at the output. Either or both of these SFP ports can be used to provide connection to the host HBAs using Fibre Channel cables. Each host port operates at 4 Gbits/sec., giving an effective speed of 8 Gbits/sec. These ports are also backwards compatible with 2 Gbits/sec. and 1 Gbps hosts. The Host Port Status LED will be illuminated steady when there is no I/O activity and will flash indicating I/O activity. A separate status LED is provided for each of the three operational speeds. If the LED is extinguished, an invalid link is indicated. A SAS expansion port provides for expanding the number of drives up to a maximum of 60 disk drives using four RS-1220-E3-XPN enclosures, all of which are connected via the 4-port SAS connector using dual cabling. The SAS expansion port operates at 3 Gbits/sec. and has four LEDs adjacent to the connector that indicate the status of each lane. An RJ45 10/100BaseT Ethernet port allows the controller to be connected to a network to enable out-of -band management and monitoring using the embedded StorView Storage Management software.
16
System Overview
Important
Only shielded Cat 5 (or better) cables should be used for connection to the Ethernet port for EMC conformance.
requires a special cable and users should NOT attach a USB cable to this port.
The white diamond icon with an arrow pointing away from the connector indicates an expansion out port.
17
The following table provides a description of the F5412E RAID Controller modules LEDs: Table 24
LED/Icon
Battery Fault
This LED appears between the controllers Ethernet and RS232 ports. Illuminated - Backup battery has low voltage, has experienced a time-out on charge indicating a faulty battery, or has experienced a fault in the charging circuitry. This LED appears between the controllers Ethernet and RS232 ports. Illuminated - RAID Controller cache has data saved in memory but not written to the disk array. This LED appears between the controllers Ethernet and RS232 ports. Illuminated - RAID Controller has activity on the bank 0 disk drives. (Drives 3, 7, 11, 4, 8, 12)
Cache Active
This LED appears between the controllers Ethernet and RS232 ports. Illuminated - RAID Controller has activity on the bank 1 disk drives. (Drives 1, 5, 9, 2, 6, 10)
Controller OK
This LED appears between the controllers Ethernet and RS232 ports. Illuminated Green - RAID Controller operation is normal. This LED appears between the controllers Ethernet and RS232 ports. Illuminated Amber - RAID Controller fault has occurred.
Controller Fault
Ethernet Status
These LEDs appear above the controllers Ethernet port. Right Side Green - Ethernet port has a link connection and link activity. Left Side Green - Ethernet port speed. When illuminated, it indicates the port is running at 100 Mbps and when Off at 10 Mbps. These LEDs appear above the controllers Fibre Channel port. Blue = 4Gbps Green = 2 Gbps Yellow = 1 Gbps Steady when no activity but valid signal and flashing to indicate activity. Both LEDs will flash which indicates no valid signal. These LEDs appear adjacent to the SAS connectors. Illuminated - They will indicate I/O activity on the specific port lane (4x lanes).
SAS Activity
18
System Overview
2.4.3.1
Battery Module
The F5412E RAID Controller module assembly includes a removable battery module, as shown in Figure 210 and Figure 212. The battery pack provides protection of the cache memory contents should the AC power fail. The battery is a replaceable Lithium-ion battery pack. When the controller is powered on, it checks to determine if a battery module is present. If none is found it assumes a battery module is not installed and is not required. Therefore, no fault condition occurs for a missing battery at power up. Otherwise, if the battery is removed or experiences a fault LED indications and software event notifications will occur. Please refer to section 6.3.6 on page 88 for removal and replacement procedures.
Figure 212
Battery Module
2.4.3.2
Figure 213 Sample SFP Optical Modules - Ejector Open and Stored Each connection is bi-directional between the Fibre Channel host side interface and the drives. The drives will not be presented to the Host until they are configured into disk arrays and logical drives, then mapped by the controller.
19
Typical supported cabling configurations are shown in section 3.6, Cabling the Enclosures, on page 46.
Important Optical SFP modules must be UL (or other North American NRTL) RECOGNIZED COMPONENT and the laser in the module must comply with Laser Class 1, US 21 CFR (J) and EN 60825-1.
2.4.3.3
Processors on the Disk I/O module provide enclosure management and the interface to the devices on the backplane, power supplies, partner Disk I/O modules and the OPS panel, all of which monitors the internal functions. These Disk I/O module processors operate in a master-slave configuration which allows for failover and failback. The enclosure may be configured with either one or two modules. If only one Disk I/O module is installed, a blank module must be installed in the unused bay. When installing a single module, install the module into the lower bay and a blank plate into the upper bay. Each SAS connector has four LEDs adjacent to the connector. The LEDs indicate status or I/O activity on that specific SAS port lane. Refer to the table on the following page for details on these LEDs.
20
System Overview
Figure 215 Disk I/O Module Front Panel The white diamond icon with an arrow pointing away from the connector indicates an expansion out port, and a white circle icon with an arrow pointing towards the connector indicates a host in port. Table 25
LED
SAS Lane
Ready, no traffic. Active, I/O traffic. Fault condition or rebooting. Not ready, no power.
Note
The out port on the RAID Controller or Disk I/O module connects to the in port on the Disk I/O module in the next RS-1220-E3-XPN enclosure in a multiple enclosure configurations. Please refer to section 3.7 on page 49 for more information on cabling the expansion enclosures.
21
Figure 216
Figure 217
22
System Overview
2.4.5.1
Figure 218 Drive Status LEDs The amber LED will only be ON if there is a drive fault. If the green LED is OFF when the amber LED is ON, a power control circuit failure is indicated. Disk drive status is monitored and the status displayed via the green and amber LEDs mounted on the front of each Drive Carrier module. They provide the following indications: Table 26
Green LED
OFF ON FLASHING
No Drive installed or blank module installed. Drive installed, powered ON, and operational. Conditions: Drive locating (user initiated) Drive is in a critical array Drives are members of a failed array Drive in an array and the arry is in rebuild mode Drive slot fault. There is a power fault on this drive slot. Drive fault. The drive is inserted but is not communicating, which is indicative of a drive failure.
OFF ON
ON ON
2.4.5.2
Anti-tamper Locks
Anti-tamper locks are a part of he drive carrier handles (Figure 219) and are accessed through the small cutout in the latch section of the handle.These are provided to disable the latch action of the handle.
23
2.4.5.3
Note
Arrays cannot be created using SATA drives that have a mixture of A/A and A/P MUX transition cards. If your enclosure has SATA drives with a mixture of MUX transition cards, the first array created will establish a precedence based on the type of drive and type of transition card first used. All subsequent arrays using SATA drives must use the same type of transition cards, otherwise you will get an invalid drive notice.
Figure 220
Drive Carrier Module with SATA Disk Drive and Active-Active MUX Transition Card
24
System Overview
Figure 221
Drive Carrier Module with SATA Disk Drive and Active-Passive MUX Transition Card
2.4.5.4
25
Warning
Operation of the enclosure with ANY modules missing will disrupt the airflow and the drives will not receive sufficient cooling. It is ESSENTIAL that all apertures are filled before operating the RS1220-F4-5412E and RS-1220-E3-XPN storage systems.
26
Getting Started
Chapter 3
Getting Started
3.1 Introduction
In this chapter, you are shown how to install your RS-1220-F4-5412E and RS-1220-E3-XPN enclosure into an industry standard 19-inch rack cabinet and configure the enclosure subsystem.
Caution Use only the power cords supplied or those which match the specification quoted in section B.5 on page 103.
Drive Slots
ALL drive slots must have a drive carrier module or dummy drive carrier module installed; no drive slot should be empty. When using SATA drives, do not mix the MUX transition cards, they must be all A/A or all A/P. Also see section 3.9, Drive Slot Arrangement, on page 50. Two power supply modules must be installed. Full power redundancy is provided from the second power supply while a faulty module is replaced. Install the power supply modules in the furthest two left hand rear bays (Figure 31 or Figure 32). Install in rear center bay, as shown in Figure 31 or Figure 32.
Cooling Module
27
Table 31
Module
Two F5412E RAID Controller modules or one F5412E RAID Controller module plus one blank module can be installed. The modules are installed one above the other in the furthest right hand rear bays (Figure 31). Two Disk I/O modules, or one Disk I/O module plus one blank module can be installed. The modules are installed horizontally (one above the other) in the furthest right hand rear bays (Figure 32).
Caution
Blank modules or Dummy Carrier modules MUST be installed in ALL unused bays or slots, otherwise there will be inadequate cooling if any are left vacant.
Figure 31
Figure 32
28
Getting Started
29
Warning
Ensure that you have installed and checked a suitable anti-static wrist or ankle strap and observe all conventional ESD precautions when handling modules and components. Avoid contact with backplane components and module connectors, etc.
For Microsoft Windows Servers - Insert the Software and Manuals Disc, click the Pseudo LUN Driver (INF) button and following the on-screen installation instructions.
Figure 33
30
Getting Started
3.4.3.1
Installation Procedure
Observe all conventional ESD precautions when handling RS-1220-F4-5412E and RS-1220-E3XPN modules and components. Avoid contact with backplane components and module connectors, etc. The enclosure when fully populated is very heavy (32 kg (70.4 lb.)). It is recommended that you use an assistant during the installation.
Important
1 2
Remove the accessory kit and upper foam inserts from the shipping carton. Using an assistant, lift the enclosure from the carton and place it on a stable surface. Remove the protective plastic wrapping and inspect for any obvious damage.
Remove the plug-in modules. This includes the disk drives, power supply modules, cooling fan module, and RAID Controller modules or Disk I/O modules (depending on which enclosure type). Refer to section 3.5, Module Removal & Installation, on page 35 for instructions to remove and re-install the plug-in modules.
Note
You should re-install the disk drives in the exact same order as they were shipped. And if you have a mixture of SATA and SAS disk drives, ensure that you re-install the drives using the same drive type in each column. You cannot mix SATA and SAS drives in a vertical column of drive slots. Place the empty enclosure chassis on a stable work surface.
31
Attach the left and right chassis slides to the enclosure sides using a total of six M3x4 button head screws (see Figure 34), three each side. The front portion of the chassis slide has two tangs which insert into holes on the forward edge of the side panel. Assemble the left and right chassis latches using the chassis latch screws. Ensure that the latch is orientated as shown in Figure 34, with the spring arm located against its stop. On the right hand this is at the top, on the left it is at the bottom.
Figure 34
7
Assemble the rack brackets to the rack posts as follows. The brackets are universal and will fit either side. (refer to Figure 35):
a Locate the guide pin at the rear of each bracket and insert the pin into a rear rack post hole.
Attach the bracket to the rear rack post using the washers and screws supplied. The screws should be left loose.
b Extend the rail to fit between the rack posts. c Attach the bracket to the front rack post using the washers and screws supplied. The screws
32
Getting Started
NOTE: Remove nut when using the tapped hole rack posts.
Figure 35
8
33
e Tighten the front rack bracket mounting screws, again, previously left loose. f Push the enclosure completely into the rack cabinet and attach to the front of the rack using the
captive fasteners on the front flanges (located just outside of the handles).
Figure 36
9
Refer to section 3.5 on page 35 for procedures to install the modules removed in preparation for the installation, then continue with section 3.5.5 on page 42 to complete the installation.
34
Getting Started
Warning
Do not remove the covers from the power supply. Danger of electric shock inside.
Figure 37
3.5.1.2
1
Caution
Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins appear to be bent.
35
Figure 38
3
Continue to push the module until it fully seats. A click should be heard as the handle latch engages.
Figure 39
2 3
Pull the latch outward to eject the module out of the enclosure. Withdraw the cooling fan module completely from the enclosure.
36
Getting Started
Figure 310
3.5.2.2
1
Caution
Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins appear to be bent.
With the latch in the open position, slide the module into the enclosure until the latch engages.
Figure 311
3
Secure the module by manually closing the latch. A click should be heard as the latch engages.
37
Caution
Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins appear to be bent.
Pull the latches outward to eject the module out of the enclosure (Figure 312).
Grip the latches as handles and withdraw the RAID Controller module (Figure 313).
38
Getting Started
3.5.3.2
Caution
Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins appear to be bent.
With the latches in the open position (see Figure 314), slide the controller module into the enclosure until the latches engage.
Figure 314
3
Secure the module by manually closing the latches. A click should be heard as the latches engage.
39
Grip the latches as handles and withdraw the module from the enclosure (Figure 317).
40
Getting Started
3.5.4.2
Caution
Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins appear to be bent.
With the latches in the open position (see Figure 318), slide the Disk I/O module into the enclosure until the latches engage.
Figure 318
3
Secure the module by manually closing the latches. A click should be heard as the latches engage.
Figure 319
41
3.5.5.1
1
Rotate the key in a counter-clockwise direction until the red indicator is not visible in the aperture beside the key. Release the Drive Carrier module handle, by pressing the latch in the handle with your finger and rotating the handle towards the right (Figure 321).
Figure 321
4 5
Gently withdraw the Drive Carrier module from the drive slot. Repeat for the remaining disk drives.
42
Getting Started
Figure 322
3.5.5.2
Warning
All drive slots must be fitted with Drive Carrier modules or Dummy Carrier modules to maintain a balanced air flow. Ensure that the carrier is orientated so that the drive handle opens to the right.
Important 1
Release the carrier handle, by pressing the latch with your finger and rotating the handle towards the right. Insert the Drive Carrier module into an empty drive slot in the enclosure.
Figure 323
3
Slide the Drive Carrier module, gently, all the way into the enclosure until it stops and seat it by pressing with your thumb on the left edge of the module (Figure 324).
43
Secure the drive carrier by closing the handle until it fully engages. A click should be heard as the latch engages and holds the handle closed (Figure 325).
44
Getting Started
3.5.5.3
1 2
Carefully insert the lock key provided into the cutout in the handle and into its socket. Rotate the key in a clockwise direction until the red indicator is visible in the aperture beside the key.
Remove the dust cover from each of the SFP slots to be populated on the RAID Controller module. Insert the SFP Transceiver into the SFP cage and push to seat it. Ensure the ejector is positioned to its stored location. Connect your fiber channel data cables as needed. Refer to section 3.6, Cabling the Enclosures, on page 46.
Figure 327
45
Figure 328
Figure 329
Figure 330
46
Getting Started
Figure 331 Dual Hosts, Dual HBAs, and Dual Controller Connections
Figure 332 Dual Host, Single HBAs, and Dual Controller Connections
47
Figure 333 Dual Host, Single HBAs, and Dual Controller Connections (Switch)
48
Getting Started
Figure 334
49
Figure 335
Figure 336 Drive Slots Population Order (Drive types (SAS/SATA) shown are examples only.)
50
Getting Started
Attach the power cords to the power supply modules. Lift the bale up, insert the power cord and place the bale over and onto the cord. Repeat for the other power supply.
Figure 337
2 3
Ensure that the Power Supply module ON/OFF button is in the OFF (0) position. Attach the power cord to the Power Distribution Unit (Figure 338) in the rack or other power source.
Warning
Before applying power, carry out the grounding checks detailed in section 3.11.
51
Warning
Some electrical circuits could be damaged if external signal cables or power control cables are present during the grounding checks.
Check for continuity between the ground pin of the IEC 320 connector on one of the Power Supply modules and any exposed metal surface of the RS-1220-F4-5412E and RS-1220-E3-XPN enclosure.
52
Getting Started
53
54
Operation
Chapter 4
Operation
4.1 Before You Begin
Before powering up the RS-1220-F4-5412E and/or RS-1220-E3-XPN enclosures, please ensure that all the modules are firmly seated in their correct bays or slots.
4.2 Power On
Caution Do not operate this equipment until the ambient temperature is within the specified operating range. If the drives have been recently installed ensure they have had time to acclimatize before operating them. Refer to section A.5, Environment, on page 98.
Note 1 2
Please refer to section 5.2.3 on page 66 for details of the OPS panel LEDs and related fault conditions. Ensure that power is applied to the power distribution units. Apply AC power to the enclosure(s). Press the power supply switch to the ON position. Repeat for the other power supply module. All LEDs on the OPS panel should be illuminated when the enclosure power is activated. During startup, the System Fault LED will flash for a second then go out, the remaining OPS panel LEDs will continue to stay illuminated until the system comes ready. Then with all systems operating normally, only the Power On LED will remain illuminated.
Note
The exception to the above LED states would be if only one power supply is working or one fan has failed, then the System Fault LED will remain illuminated. Also, a fault with a disk array, logical drive, or impacted array will cause the Logical Fault LED to remain illuminated. Power on your host system.
55
Important
If power is lost for any reason, upon restoration of power the enclosure will re-start automatically.
Under normal conditions during the boot sequence, the Cooling Fan Fault LED (amber) will be illuminated until the RAID Controller modules and/or Disk I/O modules have completed their boot up sequence.
56
Operation
A software tool is provided to configure new embedded modules. From Windows platforms it is accessed via the embedded link on the disc navigation menu and on Linux it is accessed via a command line executable. When the Embedded StorView Setup program is run, it will broadcast UDP packets and any embedded StorView module will reply with UDP packets containing their information. A list of uninitialized systems is displayed. Uninitialized systems are those which have not had the default user name and password changed. Even if a configuration is created with arrays and logical drives but the login name and password have not been changed, it will still be considered an uninitialized system. During the process of configuring an embedded module, you will be required to enter a new password and confirm that password. The default password is the word password. The embedded module is identified by its MAC and IP address. It may be more helpful during setup to configure one embedded module at a time. You will find the MAC and IP address by accessing the VT100 RAID Configuration Utility, selecting Diagnostics then choosing StorView Embedded Module Support. Select Enter StorView Embedded Module Menu Mode and choose View Network Settings.
57
Insert the Software and Manuals CD into your CD drive. the autorun program will automatically start the navigation menu. Click the Embedded StorView Setup Wizard link to begin the configuration. You are presented with a Welcome screen and instructions to proceed. Review the information and click the Next button. (Figure 41)
2 3
Figure 41
4
Welcome Screen
The program will begin searching for embedded StorView modules (Figure 42). Those embedded modules with their default password intact will be displayed with their MAC address in an Uninitialized list window. If all discovered embedded modules have had their default passwords changed, then you will be taken to the Initialized screen.
Figure 42
5
Search Screen
From the Uninitialized screen (Figure 43), select the MAC address of the embedded module you wish to configure. If you wish to use a DHCP server to assign your IP address, click the check box Use DHCP.
58
Operation
If you wish to manually configure your network setting, enter the correction information in the appropriate fields.
6
Enter a new password and confirm the new password. Click the Configure button.
Figure 43
7
Configuration Screen
If you have additional uninitialized embedded modules, select the next MAC address and choose the appropriate settings from the previous step. Once you have completed configuring all the uninitialized embedded modules and have clicked the Configure button, the wizard will display a popup message indicating all systems have been configured. It will then re-scan for systems and if none are found, you will be taken to the Initialized screen. If someone plugs in a uninitialized module system to the network (same subnet mask) during the time of the rescan or resets a systems password back to the defaults, you will be taken to the Uninitialized screen again.
Select the MAC address of the embedded module you wish to start and click the Launch StorView button. (Figure 44)
Figure 44
9
Launch Screen
Your default web browser will open with a login screen. Enter the login name and new password then click OK. The StorView Main screen will open.
59
Log in as root. Insert the Software & Manuals Disc into your CD drive. Change directories to the software location. Type:
cd [CDROM mount point path]/software/storview/embedded
Execute the Embedded StorView Setup Tool. From the command prompt, type:
./esvsetupcl-linux Embedded StorView Setup Tool. v1.0 Entering Menu Mode.
Follow the on screen prompts. At the conclusion of the setup you will be instructed on how to proceed.
60
Operation
From the StorView main screen, click the Controller icon. The Controller Information screen appears, where you will click the Shutdown button under that controllers column. If dual controllers are in use or installed be sure to click the Shutdown button under each controller. This will provide a graceful shutdown for the RAID Controllers. You may also perform a graceful shutdown of the controllers from the VT-100 RAID Configuration Utility, as the firmware interface supports this feature. Once the system has completed its shutdown process, power down the enclosures by switching the power supply switches to the OFF position. To completely isolate power from the enclosure, disconnect the power cords.
Note
61
62
Chapter 5
63
5.1.2.2 5.1.2.3
If the controller is not completing its boot sequence, consider the suggestions below to remedy the situation. Also, to observe the boot sequence for the point where the process halted, monitor the RAID Controller boot via the VT-100 interface. Check that the cables are properly connected. Try power cycling the suspect controller by ejecting the module and re-inserting it. If the Fault LED is also illuminated, there are a few steps you may take to attempt to diagnose that problem: Controller Fault LED
Monitor the boot process. Connect the serial communication cable from the Controllers RS232 port and to your host COM port or terminal. From a terminal window, observe the boot sequence. You can also capture the process to an external file. Refer to the VT-100 RAID Configuration Utility User Guide for specific details and terminal settings. If the controller boots successfully, the terminal window will clear. Type <Ctrl>+<E> and the RAID Configuration Utility Main menu will be displayed. If all the LEDs on the RAID Controller are illuminated, the controller has most likely failed. Contact your supplier for technical support. If you are still unable to determine the cause, contact your supplier for technical support.
5.1.2.4
1 2
Check that the maximum cable length have not been exceeded. The fibre channel cable supported lengths are 2m, 3m, 5m, 50m. The SAS cables supported lengths are .5m, 1m, 2m, and 5m.
64
OFF OFF
OFF ON
No AC power source is being supplied to either power supply. No AC power source is being supplied to this power supply. OR The power cord is attached to the power source, but the power supply switch is in the OFF position. OR Power supply fault is occurring such as over-temperature warning, over-voltage warning, over-current warning, or a power supply fan has failed.
ON ON
OFF ON
AC power source is present, the power supply is on and operating normally. A fan fault in the power supply has occurred.
Fault LED
Power On LED
Figure 51
During the power up sequence, the Cooling Fan Module Fault LED will be illuminated until the RAID Controller(s) or the Disk I/O module(s) have completed their boot up cycle.
65
Table 52
OFF ON
Fan OK. One or more fans have failed. OR The RAID Controller or Disk I/O module have not completed the boot sequence.
Figure 52
The OPS panel is supplied as an integral part of the enclosure core product and is not user replaceable.
Figure 53
OPS Panel
66
Table 53
ON ON ON ON
OFF ON OFF ON
OFF ON X X
Aux present, overall power failed or switched off. OPS Panel power on (5s) test state Power On, all functions good PSU Fault LED or Any PSU Fault or Fan Fault Cooling Module Over or Under temperature Fault LED RAID Controller Fault LED on lower controller RAID Controller Fault LED on upper controller RAID Controller Fault LED ESI processor/RAID Controller 0 failed ESI processor/RAID Controller 1 failed Unknown (invalid or mixed) module type installed, or 12C Bus Failure (inter ESI processor).
ON
ON
ON
ON
ON
FLASHING X
ON ON ON
FLASHING X X X OFF ON
X X X
PSU Removed:
PSU removed when two were present at Start of Day Power On, all functions good
Drive failure has occurred causing loss of availability or redundancy. Arrays performing background function SES controlled enclosure identify.
ON X
X X
FLASHING X X ON
Note
67
Battery Fault
This LED appears between the controllers Ethernet and RS232 ports. Illuminated - Backup battery has low voltage, has experienced a time-out on charge indicating a faulty battery, or has experienced a fault in the charging circuitry. This LED appears between the controllers Ethernet and RS232 ports. Illuminated - RAID Controller cache has data saved in memory but not written to the disk array. This LED appears between the controllers Ethernet and RS232 ports. Illuminated - RAID Controller has activity on the bank 0 disk drives. (Drives 3, 7, 11, 4, 8, 12)
Cache Active
This LED appears between the controllers Ethernet and RS232 ports. Illuminated - RAID Controller has activity on the bank 1 disk drives. (Drives 1, 5, 9, 2, 6, 10)
Controller OK
This LED appears between the controllers Ethernet and RS232 ports. Illuminated Green - RAID Controller operation is normal. This LED appears between the controllers Ethernet and RS232 ports. Illuminated Amber - RAID Controller fault has occurred.
Controller Fault
Ethernet Status
These LEDs appear above the controllers Ethernet port. Right Side Green - Ethernet port has a link connection and activity. Left Side Green - Ethernet port speed. When illuminated, it indicates the port is running at 100 Mbps and when Off at 10 Mbps. These LEDs appear above the controllers Fibre Channel port. Blue = 4 Gbps Green = 2 Gbps Yellow = 1 Gbps Steady when no activity but valid signal and flashing to indicate activity. Both LEDs will flash which indicates no valid signal. These LEDs appear adjacent to the SAS connectors. Illuminated - They will indicate I/O activity on the specific port lane (4x lanes).
SAS Activity
68
SAS Lane
Ready, no traffic. Active, I/O traffic. Fault condition or rebooting. Not ready, no power.
OFF ON FLASHING
No Drive installed or blank module installed. Drive installed, powered ON, and operational. Conditions: Drive locating (user initiated) Drive is in a critical array Drives are members of a failed array Drive in an array and the arry is in rebuild mode Drive slot fault. There is a power fault on this drive slot. Drive fault. The drive is inserted but is not communicating, which is indicative of a drive failure.
OFF ON
ON ON
Figure 54
69
70
5.3.1.1
Note
The RAID enclosure requires holding the mute button for 4 seconds before the self test begins, and approximately two seconds to stop the test. The Expansion enclosure will enter the self test by just pressing the button momentarily and will stop the test also by pressing the button momentarily. During the self-test you will initially hear two beeps followed by illumination of the System Fault, Logical Fault, and Box Identify LEDs. The Drive Carrier lower Fault LEDs (amber) will flash continuously during the test.
71
5.4 Troubleshooting
The following sections describe problems, with possible solutions, which can occur with your RS-1220F4-5412E and RS-1220-E3-XPN storage solution.
1 The SYSTEM FAULT The ESI processor has detected LED is flashing AMBER an internal fault or failure: on the OPS panel. Power supply module. 2 Audible Alarm
sounding.
Single cooling fan fail. RAID Controller or Disk I/O module, if an array exists with a drive Correct the thermal issue: Clear vents. fault. Correct ambient temperature A temperature warning problems. condition. The ESI processor has detected an internal fault or failure: Dual cooling fan fail. A temperature critical condition. Replace the faulty module: Cooling Fan module. Correct the thermal issue: Clear vents. Correct ambient temperature problems.
Replace the faulty module: Power Supply module. Cooling Fan module. RAID Controller or Disk I/O module.
1 The SYSTEM FAULT LED is steady AMBER on the OPS panel. 2 Audible Alarm
sounding.
Note
72
Symptom 1 OPS panel LOGICAL FAULT LED is illuminated AMBER. 2 Audible alarm
Cause
Action
Disk drive that is a member of an array has failed. The failed drive will have its Drive Fault LED is illuminated steady.
Replace the faulty disk drive and rebuild the array. Once the array has returned to a fault tolerant state, the LED will be extinguished.
sounding.
1 OPS panel LOGICAL FAULT LED is slowly flashing AMBER.
Disk drive that is a member of an impacted array, or is in a rebuild operation. Drive Fault LEDs will be flashing as well.
Once the array has returned to a fault tolerant state, the LED will be extinguished.
If the ambient air is cool (below 25C (77F)) and the fans are observed to increase in speed then some restriction on airflow may be causing additional internal temperature rise.
Note This is not a fault
condition.
The first stage in the thermal control process is for the fans to automatically increase in speed when a temperature threshold is reached. This may be caused by higher ambient temperatures in the local environment and may be perfectly normal.
Note This thresholds are
of heated air from rear to the front. Use in a fully enclosed rack installation is not recommended.
4 Check that all blank modules are in
place.
5 Reduce the ambient temperature.
73
OPS panel SYSTEM FAULT LED is ON or Flashing. A Power Supply module Fault LED is illuminated on one or more power supply modules. Audible alarm sounding. Air temperature exiting power supply is above 55C (131F).
If the internal temperature measured in the airflow through the enclosure exceeds a pre-set threshold a thermal alarm will sound. Single or dual cooling fan module failure.
Check that the local ambient environment temperature is below the 40C (104F) specification. Check the installation for any airflow restrictions at either the front or rear of the enclosure. A minimum gap of 25 mm (1 inch) at the front and 50 mm (2 inches) at the rear is recommended. Check for restrictions due to dust build-up, clean as necessary. Check for excessive re-circulation of heated air from rear to the front. Replace Cooling Fan module. If possible shutdown the enclosure and investigate the problem before continuing.
Enclosure temperature is at a OPS panel SYSTEM FAULT higher threshold than the LED is illuminated. Thermal Alarm (which should already have been activated). Audible alarm sounds continuously One or both fans have failed. and cannot be muted.
operation.
4 Check for excessive ambient
temperatures.
5 Turn the power Off to the enclosure,
74
75
76
Chapter 6
Replace a faulty drive with a drive of the same type, and equal or greater capacity. For SATA drives, the Active/Active or Active/Passive MUX Transition card must be installed and it must match whatever type the other drives are using. All transition cards must be of the same type. All drive slots must have either a Drive Carrier or Dummy Carrier module installed in order to maintain a balanced air flow. All of the supplied plug-in power supply modules, electronics modules, dummy carriers and blank modules must be in place for the air to flow correctly around the cabinet.
77
Warning
To prevent overheating do not operate the enclosure with one Power Supply removed for more than 30 minutes. The fans within the Cooling Fan module are not user replaceable, in the event of a cooling fan failure, the complete Cooling Fan module must be replaced.
Important Note
When inserting a power supply module into a operating enclosure with data I/O in progress, smoothly insert the module into the open bay and secure the latch. Roughly inserting the module could possibly cause drives to temporarily go offline which could affect ongoing data I/O operations.
78
Warning
Observe all conventional Electrostatic Discharge (ESD) precautions when handling RS-1220-F45412E and RS-1220-E3-XPN modules and components. Avoid contact with backplane components and module connectors.
6.3.1.1
Warning
Warning
To prevent overheating do not operate the enclosure with one power supply removed for more than 30 minutes.
There should always be two power supplies installed, the N+1 power system design allows your system to continue working while replacing the faulty module. The power supply module is hot swappable.
1
Make sure you identify the faulty power supply module correctly from the two modules installed. The amber Fault LED on the defective power supply should be illuminated. Place the switch to the OFF position on the power supply and disconnect the power cord. If necessary for safety purposes and isolation, remove the power source to that supply side. Push the latch on the power supply handle to the right (Figure 61), then grip the handle and pull the module out of the enclosure.
Warning
Do not remove the covers from the power supply. Danger of electric shock inside. Return the power supply to your supplier for repair.
79
Figure 61
6.3.1.2
1
Caution
Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins appear to be bent.
Figure 62
3
Continue to push the module until it fully seats. A click should be heard as the handle latch engages.
80
Note
When inserting a power supply module into a operating enclosure with data I/O in progress, smoothly insert the module into the open bay and secure the latch. Roughly inserting the module could possibly cause drives to temporarily go offline which could affect ongoing data I/O operations. Connect the power supply cords from the power source to the power supply and position the switch to the ON position.
Warning
Do not remove this module unless a replacement can be immediately added. The enclosure must not be operated without all modules in place.
Grasp the latch between your thumb and forefinger. Squeeze your thumb and forefinger together to release the latch. Pull the latch outward to eject the module out of the enclosure. Withdraw the cooling fan module completely from the enclosure.
2 3
Figure 63
6.3.2.2
1
Caution
Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins appear to be bent.
81
With the latch in the open position (see Figure 64), slide the module into the enclosure until the latch engages.
Figure 64
Note
When inserting a cooling fan module into a operating enclosure with data I/O in progress, smoothly insert the module into the open bay and secure the latch. Roughly inserting the module could possibly cause drives to temporarily go offline which could affect ongoing data I/O operations. Secure the module by manually closing the latch by pressing the latch until it locks. A click should be heard as the module latch engage. The module should be fully seated.
6.3.3.1
Warning
1 Note
If the RAID Controller to be replaced has not already been shutdown, execute a shutdown from the software interface. A multipath failover software is recommended to be installed, configured, and operational. The preferred software product is StorView Path Manager. If this is a Active-Active or dual controller configuration, upon successful shutdown, the controller will have failed over to its partner controller and the Controller Fault LED will be illuminated on the shutdown controller. If this is a Stand-Alone or single controller configuration, you must shutdown the controller. Upon successful shutdown, the Controller OK LED will still be illuminated. Verify successful shutdown of a single controller by loss of communication with the VT-100 software utility, loss of I/O activity, or StorView loss of communication with the enclosure.
82
Using two hands, grasp each latch between your thumb and forefinger of each hand. Squeeze your thumbs and forefingers together to release the latches. Pull the latches outward to eject the module out of the enclosure (Figure 65).
Figure 65
4
Using the latches as handles and withdraw the RAID Controller module (Figure 66).
Figure 66
6.3.3.2
83
Caution
Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins appear to be bent.
With the latches in the open position (see Figure 67), slide the controller module into the enclosure until the latches engage.
Figure 67
3
Secure the module by manually closing the latches (see Figure 68). A click should be heard as each latch is engaged.
Figure 68
Note
When replacing the RAID Controller, be aware that it has a default IP address assigned. If you are using Embedded StorView and a static IP address, then you will need to set the IP address. Refer to the VT100 RAID Configuration Utility User Guide in the Diagnostics chapter.
84
When replacing a Disk I/O module, be sure the verify the firmware version after power up. If the firmware versions are different, refer to the StorView RAID Module User Guide or the VT-100 RAID Configuration Utility User Guide for instructions to update the firmware.
6.3.4.1
Warning
Note
A multipath failover software is recommended to be installed, configured, and operational. The preferred software product is StorView Path Manager. If the Disk I/O module is to be replaced in a live environment, shutdown the RAID Controller that is connected to the Disk I/O module you wish to remove. Use StorView or the VT-100 software interface. This action will cause the controller to failover, as well as the path to failover protecting access to the data and maintaining continuous I/O operations. Otherwise, by just pulling a Disk I/O module in a live environment will cause unwanted array failures and I/O issues.
Using two hands, grasp each latch between your thumb and forefinger of each hand. Squeeze your thumbs and forefingers together to release the latches. Pull the latches outward to eject the module out of the enclosure (Figure 69).
Figure 69
4
Using the latches as handles and withdraw the module (Figure 610).
85
6.3.4.2
Caution
Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins appear to be bent.
With the latches in the open position (see Figure 611), slide the Disk I/O module into the enclosure until the latches engage automatically.
Figure 611
3
Secure the module by manually closing the latches. A click should be heard as the latches engage.
86
Figure 612
4
If the attached RAID Controller was shutdown, open the latches on the controller to slightly eject it, then re-insert the controller and secure the latches. This will cause the RAID Controller to restart. All operations should return to normal once the controller is booted and fail back has been accomplished. Be sure to verify that the firmware on the new Disk I/O module matches the existing module.
6.3.5.1
1 2
Removal
Using two hands, grasp each latch between your thumb and forefinger of each hand. Squeeze your thumbs and forefingers together to release the latches. Pull the latches outward to eject the module out of the enclosure (Figure 613).
87
6.3.5.2
1
Installation
With the latches in the open position (see Figure 614), place the blank module into the enclosure open bay and press in until the latches engage.
Figure 614
2
Secure the module by manually closing the latches. A click should be heard as each latch is engaged.
Warning
There is a danger of explosion if the battery is disposed of improperly. Dispose of used batteries in accordance with the manufacturers instructions and national regulations.
6.3.6.1
1
Figure 615
88
6.3.6.2
1 2
6.3.7.1
1 2 3
Figure 617
89
6.3.7.2
1
Figure 618
Warning
Observe all conventional ESD precautions when handling disk drives. Avoid contact with backplane components and module connectors.
6.3.8.1
Caution
If the anti-tamper lock is engaged, carefully insert the lock key provided into the cutout in the handle and into its socket.
90
Rotate the key in a counter-clockwise direction until the red indicator is not visible in the aperture beside the key. Release the carrier handle, by pressing the latch in the handle with your finger and rotating the handle towards the right (Figure 621).
Figure 620
4
Gently withdraw the Drive Carrier module approximately 25mm (1-inch) and wait 30 seconds for the drive to spin down. Continue to withdraw the module from the drive slot.
91
Figure 621
6.3.8.2
Warning
Important 1
Release the carrier handle, by pressing the latch in the handle with your finger and rotating the handle towards the right (Figure 622). Insert the carrier into the enclosure.
Figure 622
3
Drive Carrier Module with Handle Released - SAS Disk Drive Shown
Slide the drive carrier, gently, all the way into the enclosure until it is stopped by the camming lever on the right of the carrier (Figure 623).
92
Secure the drive carrier by closing the handle until it fully engages. A click should be heard as the latch engages and holds the handle closed (Figure 624).
Note: If the anti-tamper locks were activated before removal, please refer to section
93
6.3.9.1
1 2
Remove the key. De-activation is the reverse of this procedure, that is: Rotate the key in an counter-clockwise direction until the indicator is no longer visible in the aperture beside the key.
94
95
96
Technical Specifications
Appendix A
Technical Specifications
A.1 Dimensions
Enclosure Height Width across mounting flange Width across body of enclosure Depth from flange to rear of enclosure body Depth from flange to maximum extremity of enclosure (rear hold down) Depth from flange to furthest extremity at front of unit Inches mm
It is recommended that a rack with a depth of no less than 700 mm (27.55 inches) is used with this product.
A.2 Weight
Maximum Configuration Empty Enclosure
97
5V 12 V
11.51 A 12.29 A
13.2 A 15.1 A
13.53 A 13.17 A
15.7 A 20.1 A
A.5 Environment
Table 11 Ambient Temperature and Humidity
Temperature Range Operational Relative Humidity Max. Wet Bulb
Non-Operational 1C to 50C
Storage
Shipping
98
Technical Specifications
Airflow
System must be operated with low pressure rear exhaust installation. (Back pressure created by rack doors and obstacles not to exceed 5 pascals (0.5mm water gauge)). 0 to 3045 m (0 to 10,000 ft.) -305 to 12,192 m (-1000 to 40,000 ft.) Vertical axis 5g peak 1/2 sine, 10 ms 30g 10 ms 1/2 sine 0.21grms 5-500 Hz Random 1.04grms 2-200 Hz Random 0.3g 2-200 Hz sine Sound Power Operating: Less than 58 dB LwA measured at 23C (74F). Sound Pressure Operating: Less than 6.8 Bels LwA measured at 23C (73F).
Altitude, Operational Altitude, Non-Operational Shock, Operational Shock, Non-Operational Vibration, Operational Vibration, Non-Operational Vibration, Relocation Acoustics
Orientation & Mounting Rack Rails Rack Characteristics Safety & Approvals EMC
19" Rack mount (2 EIA Units) To fit 800 mm (31.50 inches) depth Racks compliant with IEC 297 Back pressure not exceeding 5 pascals (0.5mm water gauge) CE, UL, GS, and BSMI EN 60950-1, IEC 60950-1, UL 60950-1 EN55022 (CISPR - A), FCC A, and VCCI
103 mm x 267 mm (4 inches x 10.5 inches) component board area: 103 mm x 240 mm (4 inches x 9.5 inches). Host Ports: two 4 Gbit/sec. Fibre Channel, also supporting 2 Gbit/sec. and 1 Gbit/sec. mode. Drive Ports: 3 Gbit/sec. SAS, creates connections to a single domain of 12 drives. Rear, horizontal (2) SFP connectors for Host 0 and Host 1 Ports, to accommodate optical interconnects (LC to LC cable). (1) 4 Lane SAS Expansion port. (1) RJ45, 10/100BaseT Ethernet port. (1) RS232 port. 40 watts.
Mounting Connectors
Power Consumption
99
103 mm x 267 mm (4 inches x 10.5 inches) component board area: 103 mm x 240 mm (4 inches x 9.5 inches). (1) 4 Lane SAS Host Port (IN): (1) 4 Lane SAS Expansion Port (OUT): Rear, horizontal
Height 27.05 mm (1.06 inches) Width 106.55 mm (4.19 inches) Depth 209.55 mm (8.25 inches) 0.16 kg (.362 lb.) (carrier) 0.86 kg (1.91 lb) w/750 GB drive installed. 5C to 40C (41F to 104F) When installed in an RS-1220 system enclosure with dual power supply modules. 18.5 watts maximum
Power Dissipation
100
Appendix B
Figure B1
101
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. The supplier is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
EMC Compliance
102
SV or SVT, 18 AWG minimum, 3 conductor - 4.5 meters maximum length. NEMA 5-15P grounding-type attachment plug rated 120V 10A; or IEC 320 C14, 250V, 10A. IEC 320 C-13, 250V, 10A.
103
Warning
There is a danger of explosion if the battery is disposed of improperly. Dispose of used batteries in accordance with the manufacturers instructions and national regulations. Observe all applicable safety precautions, e.g. weight restrictions, handling batteries and lasers etc., detailed in the preceding paragraphs when dismantling and disposing of this equipment.
Important
104
Index
Index a
AC power cord 51, 103 Active-Active MUX 23 Active-Passive MUX 23, 24 Alarm Mute Push button 12, 71 Alarm Sounds On Power Up 64 Ancillary Items 95 Anti-static wrist or ankle strap 30 Anti-tamper lock 23, 94 Audible Alarm 71, 73 Auto Start Failure 70 Specification 100 Disk I/O Module LEDs 21, 69 Dongle 23 Drive Carrier LED Functions 22, 69 Drive Carrier Module 22 Installation 43 Removal 42 Drive Carrier Module Caution Label 1 Drive Carrier Module LEDs 69 Drive Carrier Module Specification 100 Drive Location Rules 50 Drive Slot Arrangement 50 Drive Slot Numbering 29 Drive Slots 10 Drive Spin Down 42, 90 Drive Startup 50 Drive Status LEDs 22 Dummy Carrier module 25 Dummy Drive Carrier Module Removal/ Replacement 94
b
Battery Fail LED/Icon RAID Controller 18, 68 Battery module 19 Battery Module Caution Label Battery Safety 4 Blank Modules 25, 94
c
Cabling Multiple Enclosures 49 Cabling the Enclosures 46 Cache Active LED/Icon RAID Controller 18, 68 Chassis Warning Label 1 Class 1 Laser Warning 4 Connectors Disk I/O Module 100 Controller Activity LED/Icon 18, 68 Controller Fail LED/Icon 18, 68 Controller OK LED Not Illuminated 64 Cooling Fan Module 14 Installation 37, 81 Removal 36 Fault LED 15 Cooling Fan Module Caution Label 2 Cooling Fan Module Current Consumption 98
e
Electric Shock Hazard Inside Label 3 Embedded StorView Initial Setup 57 Embedded StorView Module Linux 60 Microsoft Windows 58 EMC Compliance 102 EMC Precautions 103 Enclosure Installation 30 Enclosure Chassis Features 9 Enclosure Drive Slot Numbering 29 Enclosure Drive Slots 10 Enclosure Not Recognized by Host 64 Engaging the Anti-tamper Locks 45, 94 Environment 98 ESD Precautions 103 ESD precautions 30, 79 ESI processor 72 Ethernet 49 Ethernet Connection 49 Ethernet Status LEDs RAID Controller 18, 68 Expansion Enclosure 8 Rear View 8
d
Disk Drive LEDs 56 Disk Drive status 69 Disk I/O Module 20
105
f
F5412E RAID Controller Module 16 Faulty Connections 63 FC Host Port Status 18, 68 FCC 101 Federal Communications Commission 102 Fibre Channel Interface 19 Firmware Updates 75
p
Plug-in Modules 13 Power Cord Connection 51 Power Distribution Unit 51 Power Distribution Unit (PDU) 30 Power Down 61 Power On 55 Power Supply Installation 35, 80 Power Supply LEDs 14 Power Supply Module 13 Removal 35 Power Supply Module Caution Label Power Supply Module LEDs 65 Power Supply Modules 79 Power Supply Ratings Label 2 Power Supply Safety 2, 102 Power Supply Specifications 98 Power Supply Warning Label 3
g
Grounding Checks 52 GS 101
h
Hardware Faults 77 HBA 30
i
IEC 320 connector 52 Initial Start-up Problems 63 Installation Procedures 30 Installing a Battery Module 89 Installing a Cooling Fan Module 37 Installing a Drive Carrier 43, 92 Installing a RAID Controller 39, 83 Installing an Power Supply 35
r
Rack Distribution System 52 Rack Installation Pre-Requisites 31 Rail Kit 31 Rack Installation Procedure 31 Rack System Precautions 4 RAID Configuration Utility 53 RAID Controller Module Installation 39 Removal 38 RAID Controller Module Caution Label 2 RAID Controller Module LEDs 16 RAID Enclosure 7 Rear View 8 RAID Module Specification 99 Recycling 104 Removing Disk I/O Module 40 RAID Controller 38, 82 Removing a Battery Module 88 Removing a Cooling Fan Module 36, 81 Removing a Drive Carrier 42, 90 Removing a Power Supply 35 Replacement Parts 95 Replacing a Module 79 RJ45 10/100 BaseT Ethernet port 16 RJ45 Ethernet port 49 RS-1220-E311-XPN 8
l
LED Test Mode OPS Panel 71
m
Maximum cable length 64 Mini-SAS connector 16 Module Locations 28 Mounting the Enclosure 34 MUX Transition Card 23
o
Operators Panel 10 OPS Panel 10, 66 OPS Panel LEDs 10, 71
106
Index
v
VCCI 101 Visible Alarms LEDs 11 Voltage Operating Ranges 13
s
SAS Activity LED/Icon RAID Controller 18, 68 SAS Activity LEDs Disk I/O Module 21, 69 SAS cables 49 SCSI Enclosure Services 70 Securing Brackets to Rack 33 Securing Chassis Slides to Enclosure 32 SES 70 SES Control Page 2 70 SES Status Page 0x0A 70 SES Status Page 0x0E 70 SES Status Page 1 70 SES Status Pages 0 70 SFP Optical Modules 19 SFP port 16 SFP Transceiver Installation 45 Small Form Factor Pluggable (SFP) modules 16 Specification Disk I/O Module 100 RAID Controller 99 Starting StorView 57 Starting the Drives 56 Status Indicators (LEDs) 65 StorView Storage Management software 20, 53 System airflow 14 SYSTEM FAULT LED 74 System Faults 72
w
WEEE 104 Weight 97 White diamond icon 17
t
Thermal Alarm 74 Thermal Control 73 Thermal Warnings 74 Transition Card, MUX 23 Troubleshooting 72 Troubleshooting using StorView 63
u
Unpacking the Enclosure System 30
107