JOB NAME:________________________________________LOCATION:________________________________________

PURCHASER:______________________________________ORDER NO:________________________________________
ENGINEER:__________________________________________________________________________________________
SUBMITTED TO:__________________ FOR: _______ REF: ________APPROVAL: ________ CONSTRUCTION:________
SUBMITTED BY:____________________________________DATE:_____________________________________________
UNIT DESIGNATION: SCHEDULE NO. __________________MODEL NO:________________________________________
COOLING PERFORMANCE
TOTAL CAPACITY
_____ MBH
SENSIBLE CAPACITY
_____ MBH
OUTDOOR DESIGN TMP. _________ F DB/WB
TOTAL SUPPLY AIR
TEMP. OF AIR ENTERING
EVAPORATOR COIL
POWER INPUT REQ.

_____ CFM

30-11/32
50-3/4

Control
Entry
7/8

Power
Entry
2-1/2

_____ F
_____ KW

(LESS BLOWER MOTOR)

Power
Entry
2-1/2

4-1/4

HEATING PERFORMANCE
ELECTRIC HEAT
GAS-FIRED INPUT CAP.

11-1/2
Convenience
Power
Outlet
Entry
7/8

_____ KW
_____ MBH
30-3/16

SUPPLY AIR BLOWER PERFORMANCE

24-3/16

59

6-3/16

LEFT

TOTAL SUPPLY AIR


EXT. STATIC PRESS.

_____ CFM
_____ IWG

BLOWER SPEED
POWER OUTPUT REQ.

____ RPM
_____ BHP

MOTOR RATING

_____ HP

POWER INPUT REQ.

_____ KW

FRONT

17-3/16

89

27

3 2 -1 1 /1 6
6 -1 3 /1 6

6 -1 3 /1 6

ELECTRICAL DATA
POWER SUPPLY
TOTAL UNIT AMPACITY

__________
_____ AMPS

MAX. OVERCURRENT DEVICE


__ FUSE __ BREAKER

_____ AMPS

R E T U R N
A IR

6 -1 3 /1 6

S U P P L Y
A IR
2 4
2 7 -1 /2

2 1

L E F T

TOTAL UNIT WEIGHT

1 8

INCLUDING FACTORY- INSTALLED


OPTIONS

_____ LBS

1 9 -3 /1 6
2 1 -3 /1 6

1 7 -3 /1 6

1 2 -5 /1 6

1 4 -2 3 /3 2
1 6 -3 /8
1 8 -1 /1 6

B o tto m
C o n tro
C o n v e
O u tle t
E n try

P o w e r,
l a n d
n ie n c e
W ir in g

F R O N T

B o tto m g a s
s u p p ly e n tr y

6 3 -1 /2

SINGLE PACKAGE AIR CONDITIONERS AND


GAS/ELECTRIC HEAT UNITS
6-1/2 THROUGH 12-1/2 TONS
MODEL DM/H 078 - 150

FORM: 036-22002-001 (100)


Supersedes: Nothing

FACTORY INSTALLED OPTIONS


ALTERNATE INDOOR BLOWER MOTOR - - - - - - - - - - - - - - - - V

UNIT CLEARANCES
Top1

72

Right

Synthesys - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

Front

36

Left

Novar - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

36

BAS OPTION

Rear

COIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

12
36
3

Bottom

1. Units must be installed outdoors. Overhanging structure or


shrubs should not obstruct condenser air discharge outlet.
2. To remove the slide-out drain pan, a rear clearance of 60 is
required. If space is unavailable, the drain pan can be
removed through the front by separating the corner wall.
3. Units may be installed on combustible floors made from
wood or class A, B or C roof covering materials.

CONVENIENCE OUTLET - - - - - - - - - - - - - - - - - - - - - - - - - - - V
DIRTY FILTER SWITCH - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
DISCONNECT SWITCH - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
ECONOMIZER

Barometric Relief - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
Power Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

1 8 -1 /4

Dual Enthalpy - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
MOTORIZED AIR DAMPER- - - - - - - - - - - - - - - - - - - - - - - - - - V
PHASE MONITOR1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
SMOKE DETECTOR

R e tu rn
A ir

Supply Air - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
Return Air- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

S u p p ly
A ir

STAINLESS STEEL HEAT EXCHANGER - - - - - - - - - - - - - - - - - V


TECHNICOAT CONDENSER COILS - - - - - - - - - - - - - - - - - - - - V

2 8 -1 /4

1 8 -1 /4
1 8 -1 /1 6

FIELD INSTALLED ACCESSORIES


-60F GAS HEAT KIT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
COIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

2 -3 1 /3 2
5 -5 /3 2

2 8 -1 /4

DIRTY FILTER SWITCH - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

3 1 -1 1 /1 6

DISCONNECT SWITCH - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
ECONOMIZER

Barometric Relief - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
Power Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

R IG H T

Dual Enthalpy - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

8 0 -5 /8

CO2 Sensor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
ELECTRIC HEATER MODEL- - -________________________

IN S U L A T E D D E C K U N D E R
C O N D E N S E R S E C T IO N

2 0

FLUE EXTENSION KIT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

2 0

S U P P L Y
6

GAS HEAT HIGH ALTITUDE KIT

Natural Gas - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

2 T Y P .

R E T U R N

Propane - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
GAS HEAT PROPANE ADAPTER KIT - - - - - - - - - - - - - - - - - - - V
HAIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

3 0
IN S U L A T E D D E C K U N D E R
C O M P R E S S O R S E C T IO N

5 0 -1 /2

LOW AMBIENT KIT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

F R O N T

8 o r 1 4

MOTORIZED OUTDOOR AIR DAMPER - - - - - - - - - - - - - - - - - - V


MANUAL OUTDOOR AIR DAMPER - - - - - - - - - - - - - - - - - - - - V
PERMANENT FILTERS - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

2 T Y P

PHASE MONITOR1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
ROOF CURB

5 0 -1 /2

8 Roof Curb- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

3 0 -1 /2

2 3
4

8 0 -5 /8

2 6

14 Roof Curb - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
Transition Roof Curb - - - - - - - - - - - - - - - - - - - - - - - - - - - V
Burglar Bars (Downflow Only) - - - - - - - - - - - - - - - - - - - - V

1 0

SMOKE DETECTOR

Supply Air - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V
Return Air- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V

7 6 -5 /8
9 4
F R O N T

1. Phase monitor standard on units with scroll compressors.

5 9 -1 /4
6 4 -1 /4

R IG H T