Sei sulla pagina 1di 96

Litespan Aneto

May 2008

Agenda

1. Whats new?

2. Equipment description

3. Boards description

4. Operation and maintenance

5. Future evolution

6. Practises

1
All Rights Reserved Alcatel-Lucent 2008, XXXXX

Whats new?

3 | Presentation Title | Month 2008

Whats new?

Subrack and Racks

New subracks and racks configurations

New subrack MLS_3F has been introduced. This new subrack can be used either as MAIN subrack or as

EXTENSION subrack.

The Alcatel 1540 Litespan supports a variety of different scenarios. Different configurations of the

new subrack in a rack allow a maximum of 3840 NB POTS suscribers only .

4 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Whats new? MLS-3F without and with cover

Subrack

Lab model with 3xMLS-3F + MLS-lee21

5 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Whats new?

Boards

New LIOC

LIOC (Local Input/Output Card). This board is used in the first position of MLS_3F subrack.

The board includes mainly the functions of outband Ethernet O&M, craft terminal, G.703

synchronization interface and external alarms collection. This card is based on previous FR2.X

Litespan cards TAUP, HBMPA and HBMPB.

External interfaces available on LIOC are:

External alarms Input/Output.

Ethernet interface for the system and connections from every controller (NB, BB and ADM's)

allowing one only external O&M for all the system controller elements.

Craft Terminal.

G.703 synchronization interface.

6 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Whats new?

Boards

PEIC

Power and E1 Interface Card. Functions are as follows:

o Power feeding interface.

o 16 x E1 external interfaces.

o NLC buses termination.

o Configurable straps for MLS numbering.

NEHC-C

The Narrowband Element Handler Controller (NEHC) performs the narrowband controller function as

Network Element Controller in MLS subrack. This new NEHC-C PDH would be used only in PDH / TDM

applications. This new NEHC-C PDH do not support some functionality previously supported as:

o X.25 management interface.

o DCC management interface.

o EOTC-B is not managed since this interface is removed.


All Rights Reserved Alcatel-Lucent 2008, XXXXX

7 | Presentation Title | Month 2008

Whats new?

Boards

NSEC

New Narrowband Shelf Extension Controller for the Alcatel Litespan FR3.0 system.

The card is based on the previous NSEC-HS. It keeps the same functions of the old, including NLC

bus extension, former LEEP plug functionality.

The main difference between the two cards is the size. The NLC bus extension lines are located in a

special connector at the front side of the card.

ATLCF

It is a 48 subscribers POTS line card. The main impact of this new equipment practice in line cards is

that the access to subscriber lines is now performed through front-plate connector instead of rear

back-plane connectors.

ATL3G

It is a 48 subscribers POTS line card. The PBA-ATL3G-48 is developed as a functional variant of the

PBA-ATLCF-48 that uses Vinetic-4S codec instead of the Vinetic-4C used in the ATLCF; this has some

impacts in initialization of the board and in Line testing functionality .


All Rights Reserved Alcatel-Lucent 2008, XXXXX

8 | Presentation Title | Month 2008

Whats new?

Boards

PEIC

Power and E1 Interface Card. Functions are as follows:

o Power feeding interface.

o 16 x E1 external interfaces.

o NLC buses termination.

o Configurable straps for MLS numbering.

NEHC-C

The Narrowband Element Handler Controller (NEHC) performs the narrowband controller function as

Network Element Controller in MLS subrack. This new NEHC-C PDH would be used only in PDH / TDM

applications. This new NEHC-C PDH do not support some functionality previously supported as:

o X.25 management interface.

o DCC management interface.

o EOTC-B is not managed since this interface is removed.


All Rights Reserved Alcatel-Lucent 2008, XXXXX

9 | Presentation Title | Month 2008

2
All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

10 | Presentation Title | Month 2008

Equipment description

General

FE

VoIP Gateway

PDH NB Shelf Controller Transport Bus Internal BB Shelf Controller BB Line Card Test Card busses Litespan

SDH/PDH Transport

PDH

STM-1 UNI Alarm Card Ringer Card

NB Line Card

Server Card

Ethernet Transport

FE, GE

11 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description Constant Enhancement of Product Capacity


Release 3.x Housing

3,840 2,556
MLS-3F

Mass-Market Multiservice

2,430

2,250

MLS-3F MLS-3F

MLS-3F

MLS-3F
Outdoor 2 MLS Indoor up to 4 MLS

2002

2003

2006

2007

Maximum POTS capacity per indoor rack

1920 POTS 960 ADSL 432 ADSL

3840 POTS 1920 ADSL Splitter-less 864 ADSL Splittered

POTS & ADSL capacity (up to)


All Rights Reserved Alcatel-Lucent 2008, XXXXX

12 | Presentation Title | Month 2008

Equipment description New Alcatel-Lucent 1540 Litespan MSAN Release 3


Release 3.x Housing Mass-Market Multiservice Multiservice Applications

Release 2.x Housing

Voice-intensive Applications

MLS lee21 MLS lee21 MLS-hb MLS-hbe MLS-hbe

MLS

lee21

MLS-3F

MLS

lee21

MLS-3F MLS-3F

MLS-le

MLS MLS-hbe
MLS-hb Indoor up to 4 MLS Outdoor 2 MLS

MLS-le

MLS-hb
Indoor
up to

lee21

MLS-3F
Outdoor 2 MLS

MLS-3F
Indoor up to 4 MLS

Outdoor 2 MLS

Indoor up to 4 MLS

4 MLS (NB) 12MLS (BB)

1212 POTS 432 ADSL

2556 POTS

1152 POTS

2528 POTS 192 ADSL

2432 POTS 912 ADSL

1920 POTS 432 ADSL

3840 POTS 864 ADSL

POTS capacity (up to)

POTS & ADSL capacity (up to)


All Rights Reserved Alcatel-Lucent 2008, XXXXX

POTS & ADSL capacity (up to)

13 | Presentation Title | Month 2008

Equipment description
ATM Bus 155Mbps
Narrowband LIM

Buses
TDM Bus 51Mbps

Local 1000/100/10 BaseT (x4)

Ethernet Controller

GE p2p links

POTS ISDN BA ISDN PRA Digital LL SHDSL

STM-1/ IMA
ATM bridge

Ethernet Broadband LIMs

ADSL2+ VDSL2 (future)

Narrowband Controller

Local E1 (16x)

Local 100 BaseT

VoIP Gateway Servers

Server Bus 4x8 Mbps

Backpanel connections

External connections

Plug or connector

14 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: same NB machine as in FR2

Same carrier grade TDM/NGN architecture with an increase of PSTN density to 48UP/card.

HW changes for cost optimisation minimizing SW impact.


TDM Bus 51Mbps
Narrowband LIM

POTS ISDN BA ISDN PRA Digital LL SHDSL

ATM

Narrowband Controller

Local E1 (16x)
VoIP Gateway Servers

Local 100 BaseT


Server Bus 4x8 Mbps

15 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: BB-IP machine (ISAM inside)

Same BB-IP architecture of ISAM, not only in MLS-main but also in MLS extensions.

NTIO and transport capability separated from BB-IP controller

SFP 1000/100 (x2)

Ethernet Controller

GE p2p links

Local 1000/100/10 BaseT (x4)


ATM

Ethernet Broadband LIMs

ADSL2+ VDSL2 (future)

16 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: ATM

ATM native bus (IQ bus) removed: ANETO is not ASAM inside since 155Mbps bus is limited for Triple-

Play deployment

ATM uplink connectivity for BB-IP controller (IP to ATM bridge)

SFP 1000/100 (x2)

Ethernet Controller

GE p2p links

Local 1000/100/10 BaseT (x4)


ATM bridge Ethernet Broadband LIMs

STM-1, E3, 8xE1IMA UNI

ADSL2+ VDSL2 (future)

17 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: SDH

1650-SDH integrated no longer supported due to the lack of Ethernet transportation.

New integrated ADM for TDM and Ethernet (EoS) SDH transport capability into STM-1/4/16
TDM Bus 51Mbps

SFP 1000/100 (x2)

Ethernet Controller

GE p2p links

Narrowband LIM

POTS ISDN BA ISDN PRA Digital LL SHDSL

Local 1000/100/10 BaseT (x4)


ATM bridge

STM-1 E3 E1IMA UNI

Ethernet Broadband LIMs

ADSL2+ VDSL2 (future)

ADM, SDH

STM-1/4/16
Narrowband Controller

New

Transmission

Local E1 (16x)

Local 100 BaseT


Server Bus 4x8 Mbps

VoIP Gateway Servers

18 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: MLSs boards

Uplink interfaces Services


10/100/1000 BaseT Optical GE (SX, LX, EX,) LL card (Future release)
SHDSL card (Future Release)

Terminals

Ethernet (FE/GE)

Ethernet Controller

STM-1/E3/E1

ATM Bridge

EFL3x 24 ADSL1/2/2+

3-Play non-blocking

STM-1/4

Integrated ADM (Future Release)

16xE1
ATL3x 48 POTS

Narrowband Controller

Commercial, 300-3,400 Hz

Ethernet (FE)

VoIP Server

BAL3x

16 ISDN NT

ISDN commercial

Embedded Line Testing

19 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: MLS-3F
20 L I M V I S C N I O C A D M V I S C 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 480

Width (mm) Card

I/O AUXILIARY

L I O C

30 P E I C

25 L I M G E B C

25 L I M G E B C

NB CTL/EXT

N I O C A D M

BB CTL & Transport

NB slot 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8

20 N E H C N S E C N B S C 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 9 10 11 12 13 14 15 16 17 18 19 20 10 12 13 14 15 16 17 18 19 20 13 14 15 16 17 18 19 20

20 N E H C N S E C N B S C 4

NB-only LIM numbering NB&BB w/o Xp LIM numbering NB&BB w Xp LIM numbering

Total slots 20 18 16

NB user ports NB 48 16 TBC max Shelf type NB type slots PSTN ISDN LL NB only TDM 20 960 320 NGN (VIS3B) 18 864 288 NB&BB (GEB3A) TDM 18 864 288 NGN (VIS3B) 16 768 256 NB&BB&TP TDM 16 768 256 NGN (VIS3B) 14 672 224
All Rights Reserved Alcatel-Lucent 2008, XXXXX

BB user ports BB 24 24 max ADSL2+ ADSL2+ slots (w/o Splt) (w Splt)

16 14 16 14

384 336 384 336

192 168 192 168

20 | Presentation Title | Month 2008

Equipment description MLS-3F shelf

21 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: single shelf for all combinations

NB main/ext +BB main/ext with TT


L L L L L L L L L I I I I I I I I I M M M M M M M M M

NB main
L I O C N E H C V I S C V I S C N E H C P E I C L L L L L L L L L L L L L L L L L L L L I I I I I I I I I I I I I I I I I I I I M M M M M M M M M M M M M M M M M M M M

L I O C N I O C A D M

P E I C

N E H C N S E C N B S C

N E H C N S E C N B S C

L L L L L L L L L I I I I I I I I I M M M M M M M M M G - E V V I I B S S C C C

L L I I M M - G N E I B O C C A D M

N B S C

N B S C

Optional integrated transport NB ext


P E I C N S E C N S E C L L L L L L L L L L L L L L L L L L L L I I I I I I I I I I I I I I I I I I I I M M M M M M M M M M M M M M M M M M M M
L L L L L L L L L L I I I I I I I I I I M M M M M M M M M M G E B C

L I O C

P E I C

NB main/ext +BB main/ext w/o TT

N E H C N S E C N B S C

N E H C N S E C N B S C

L L L L L L L L L L I I I I I I I I I I M M M M M M M M M M - G E V V B I I S S C C C

22 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: single shelf for all combinations

Equipment configurations. Shelves combination.

FR3 shelves may be combined in a flexible way

NB main is always the 1st shelf. All the rest are NB extensions

All shelves can be BB main

ADM transport configurations are only supported in 1st shelf.

NIOC based configs are only supported when shelf is BB-main

MLS-lee21 as extension shelf for special services(LL) and EU-RU configs

MLS-lee21 may be equipped in 2nd, 3rd, or 4th MLSs of the node

Subsystem Main Main OK OK -OK(MainBB) Main/Ext Ext

1st shelf

2nd shelf

3rd shelf Ext Main/Ext -OK(MainBB)

4th shelf Ext Main/Ext -OK (MainBB)

NB

BB

ADM

NIOC

23 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: cards

FR3 cards have same PCB size than FR2 cards

Re-layouts to move UP connections from back-plane to front-plate

Front-plate and levers adaptation to new equipment practice

When possible, ANETO variants same naming rule replacing C by 3

GEB3-A (FR3) correspond to same functionality of GEBC-A (FR2) ATL3-G (48UP)

ATLC-E (32UP)

24 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: Subscribers front access in LIM boards

MLS-3F provides MDF cable access in the front plate of the boards, not in the back-plane

Metral connectors replaced by a DIN-96 connector in the front-plate

96p MDF cable (same MDF raw cable of 96p as FR2: 1AC-02319-0001): two slots connected by a

single cable.

Cable shield connected to earth at the bottom plate of MLS-3F

FR2 MDF connection

25 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: Front cabling through the electronics area

Improved connection capabilities for front-access connections

MDF connectivity for LIMs through the bottom edge

Power & E1 though the top edge

CT, SYNC, LAN, Auxiliar through bottom edge

NLC extension through bottom & top edges

Gap between fan and MLS to provide room for additional

cables and Fibers routed through the top edge

26 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: Card insertion/extraction

Modified pulling handles, with embedded latching system

27 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: Card operation for maintenance

Once MDF connector is extracted, card can be inserted extracted without difficulty

28 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: Common parts cabling

All cabling of POWP, HBMP and TAUP are moved into LIOC and PEIC cards MLS-3F I/O cabling

NLC extensions are moved into NEHC and NSEC

MLS-hb16 I/O solution in plug area PEIC Power E1s LIOC CT LAN Sync AUX NEHC/NSEC NLC ext
All Rights Reserved Alcatel-Lucent 2008, XXXXX

29 | Presentation Title | Month 2008

Equipment description
NEHCC Narrowband traffic Controller V5 signalling termination Network management interface with 1353 LMS System clock transmission for PDH transport systems Termination of HDLC for ISDN subscribers Master Database in non-volatile memory NSECC TDM bus and synchronism connection to Extension shelf Subtending interface for additional Extension shelves

R3 architecture: New Narrowband and extension controller variants for 3F MLS

30 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description GEB3-A


Pluggable in Broadband Controller slot of MLS Non-blocking matrix: 1 Gb/s per multi-DSL line card Optical: 1000Base (SM, MM, SX, LX, EX, ZX) Electrical: Auto-sensing 100/1000BaseT 1+1 protection 2 GigE plus 4 Fast/GigE ports
B GE 3-A

R3 architecture: GigEthernet Broadband Controller (GEB3A variant for 3F shelf)

IGMP snooping (version 3) DHCP relay option 82 Traffic prioritization in VLAN (802.1 p/q) Spanning Tree (RSTP)

Subtending GE Star

Uplink

2xGE electrical GE

-A B3

Cascading Options
B GE 3-A

Port aggregation and VLAN stacking RIP & OSPF


All Rights Reserved Alcatel-Lucent 2008, XXXXX

31 | Presentation Title | Month 2008

Equipment description

R3 architecture: ATM connectivity in 3F MLS

ATM Bridge card Subsystem for interfacing to ATM uplinks


STM1 IP2ATM 8xE1 2xE3

GEB3A IP to ATM conversion

Different Up-links physical interfaces


STM-1 8x E1-IMA

GEB3A ATM Bridge card

2 x E3

32 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: Voice over IP server variant for 3F MLS (VIS3-B)

Class 5 Replacement
Voice codecs: ITU-T G.711 (64 Kb/s) ITU-T G.729A (8 Kb/s) ITU-T G.723.1 (6,3 and 5,3 Kb/s) Echo cancellation ITU-T G.165 ITU-T G.168 Voice activity detection (VAD) Comfort noise generation (CNG) Packet loss concealment (PLC)

Voice Processing Functions

Multiple tone detection and generation

DTMF and pulsed digit detection

Digit map processing

End-to-end tone detection/generation/notification (RFC 2833)

Line event management

Caller identification services (FSK and DTMF, CLIP and CWID)

Support for other supplementary services (CW, CH, CF, etc.)

33 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description
ATL3-G
48 customer lines 24 mA line current feeding ( 6 lines can deliver 40 mA, configurable by Z interface) Automatic reduction of line current during restricted batteries). Ring voltage and 12 kHz/16 kHz metering insertion Polarity reversal. Programmable cancellation Programmable gain level. Over voltage detection. Z interface adaptable to national specification on CDE basis Specification in accordance with ITU-T Recommendations Q.552, G.712 for interface Z
All Rights Reserved Alcatel-Lucent 2008, XXXXX

R3 architecture: New POTS card variants for 3F MLS

power

operation

(i.e.

backup

line

impedance

with

echo

protection

and

over

current

34 | Presentation Title | Month 2008

Equipment description

R3 architecture: New ISDN board variants for 3F MLS BAL3-G (2B1Q line code) BAL3-H (4B3T line code)
16 lines/board Integrated line testing

Remote power feeding for NT (feeding voltage at 70 V or 97 V) Feeding current up to 40 mA. OAM capability.
Embedded operation channel, allowing the following operations. Bit error rate, including repeater sections. Loop management. Detection of line errors (no start-up upon activation, loss of frame, etc.). Overcurrent detection in the power feeding system.

35 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: New MultiDSL board variants for 3F MLS

EFL3-B (POTS splitter-less) 24 MultiDSL ports (ADSL/2/2+) MAC and IP Packet forwarding PPPoE relay DHCP relay PPPoA to PPPoE relay IEEE 802.1x user authentification MultiDSL over ISDN (EFL3H version) Embedded splitters for POTS or ISDN
EFL3A version for POTS w Splitter EFL3I version for ISDN w Splitter

36 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: 1540 Litespan Upgrade to Triple-Play

Ethernet L2/L3 Giga-Ethernet

LAN users Leased lines POTS/ ISDN

Ethernet / IP Network

ISP HSI

1540 Litespan

HSI xDSL
Video

Video

GEB3A

Ethernet L2/L3 Controller

Invest now in revenue-generating services while preparing for the services of tomorrow.

EFL3-B

ADSL2+ 24 ports Splitters on board

37 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: Auxiliary boards for 3F MLS

PEIC Powering unit PDH transport interfaces (16xE1) Shared slot with LIOC card

LIOC Shared slot with PEIC card Craft Terminal interface for Narrowband controller LAN interface for Qecc transport Auxiliary alarms and Top Rack Unit Synchronism functionality

38 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Equipment description

R3 architecture: 3F MLS single shelf for all purposes

Multi-service configuration (main or extension)


L L L L L L L L L I I I I I I I I I M M M M M M M M M - G V V E I I B S S C C C L L L L L L L L L I I I I I I I I I M M M M M M M M M N I O C A D M N E H C N S E C N B S C N E H C N S E C N B S C L L I I M M - G N E I B O C C A D M

L I O C

P E I C

Optional SDH integrated transport Voice in NGN (extension shelf)


P E I C N S E C N S E C L L L L L L L L L L L L L L L L L L L L I I I I I I I I I I I I I I I I I I I I M M M M M M M M M M M M M M M M M M M M

Voice in NGN (main shelf)

L I O C

P E I C

N E H C -

N E H C -

L L L L L L L L L L L L L L L L L L L L I I I I I I I I I I I I I I I I I I I I M M M M M M M M M M M M M M M M M M M M

V I S C

V I S C

N B S C

N B S C

39 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

3
All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

40 | Presentation Title | Month 2008

Boards description

LIOC

This board is used in the first position of MLS_3F subrack.

The board includes mainly the functions of outband Ethernet O&M, craft terminal, G.703

synchronization interface and external alarms collection.

The LIOC assumes the RI functions in MBTP and TAUP in the current MLS's. It places together the

information distributed in the current practice in TAUP and MBTP plugs in one only RI EPROM

accessible via IAB from NEHC. The IAB interface is used as well for communication of external alarms.

This card is based on previous FR2.X Litespan cards POWP, MBTP, TAUP, HBMPA and HBMPB. External

interfaces available on LIOC are:

Ethernet interface for the system and connections from every controller (NB, BB and ADM's)

External alarms Input/Output.

Craft Terminal.

G.703 synchronization interface. One external input (T3 interface) / One output (T4)

With new board PEIC is the local I/O card that resumes all the plugs used in Litespan FR2 TAUP, HBMP)
All Rights Reserved Alcatel-Lucent 2008, XXXXX

(POWP,

41 | Presentation Title | Month 2008

Boards description

LIOC

E1 Synchronization Interface use the RJ45, X205 front panel connector


A1 A2 A3 A4 A5 A6 T3_IN_N T3_IN_P EG EG T4_O_N T4_O_P

The board collects external alarms through the metral connectors X201, X202 and X203 as can be seen

in front panel from several external devices, which will be stored in the memory in CPLD. The NB

controller through the IAB bus will read these alarms. In the same way, several controls and

commands ordered by the NB controller are managed by the LIOC. This part of the LIOC is strongly

based on TAUP test alarm and aux plug specification

42 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

LIOC
STATUS / LED All OFF (No alarm nor attention of alarms) All ON (URG and NURG alarms as well as Light attended) URG ON, rest OFF Flash URG OFF, rest ON NURG ON, rest OFF NURG OFF, rest ON ATTD ON, rest off ATTD OFF, rest on Dark Light Dark Light Switch1 On On Off Off Flash Light Dark Light Flash Flash Light Dark Switch2 On Off On Off Dark Dark LED1 (GREEN) LED2 (YELLOW)

L E D 1 (G R E E N )

L E D 2 (Y E L L O W )

S1

X204

C RA FT

X206

O&M

X205

C lo c k Im p u t

X201

State Operate normally Attend alarms Stop alarms Lamp tests

X202

X203

43 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

LIOC

CRAFT TERMINAL INTERFACE

Through a RS232 interface on the front panel the craft terminal is connected.

The connector used is RJ11 on the front panel, and the signals are RXD_CT, TXD_CT, DTR_CT, CD,

DSR_CT and EG. The type is asynchronous, full duplex, 1 starts bit, 8 data, 1 parity programmable bit,

1 stop bit, while the speed is Configurable and can be up to 9600 b/s. There is a RS232 receiver and

transmitter used.

Craft terminal uses X204 front panel connector

OUTBAND ETHERNET LAN CONNECTION FOR NETWORK MANAGEMENT

The LIOC includes one external interface for the system. This interface is connected to an internal

switch in LIOC and the Aneto MLS provides connections from every controller (NB-CCs, BB-CCs and

ADM's) to that switch, allowing in the future one only external O&M for all the system controller

elements and internal control communication among all of them

Outband ethernet lan connection for network management uses X206 connector

44 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

LIOC

ETHERNET SWITCH

LIOC includes one simple Ethernet switch that provides from one side one common Ethernet interface

for outband management and on the other side control plane communication when needed (future

releases) among the NB, BB controllers and ADM slots. Differential interfaces (HCL type) are routed

from all these slots to the LIOC position, each one connected to a differential port in the switch.

An initial ARP has to be sent during start up by the master controller to guarantee that the MAC

address used for O&M is assigned to proper switch port.

45 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

PEIC

This card is based on other Litespan cards POWPA, PATC, HBMPA and HBMPB.The PEIC is part of the

cards equipped on the subrack MLS_3F. The board is to be inserted face to face with LIOC card.

As it can be seen PEIC is plugged rotated 180 in relation with the usual plug orientation.

PEIC functions are as follows:

Power feeding interface, A and B branches.

16 x E1 external interfaces from/to both NEHC's. The 16 x E1 are routed by backplane towards the

NIOC/ADM positions as well for future integrated and redundant transport.

NLC buses termination

Configurable straps for MLS numbering, SUB_POS0 and SUB_POS1.

The IAB bus in Aneto MLS is available in the PEIC position

No presence wire is available for PEIC (on the other hand if such card is not present, no power feeding

is available and the system is fully down).

46 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

PEIC

POWER
POW ER CONNECTOR

FEED

INTERFACE

PEIC includes the battery

power supply connection


1 -4 E 1 C H A N E LS 5 -8 E 1 C H A N E LS

to subrack and related


Connector
9 -1 2 E 1 C H A N E LS 1 3 -1 6 E 1 C H A N ELS

filtering. A power SUB-D

connector on front end is


1 BAT_INA

used, as a simple power

cable containing BAT_A,


2 BAT_INB

BAT_B and BAT_RIN from


3 BAT_INR

TRU. In the PEIC board,

no fuse is equipped and

external

overcurrent /

shortcircuit

protection

should be provided at

rack/subrack level

47 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

PEIC

E1 INTERFACES

PEIC include 16 x E1 from/to both

NEHC's. The design of the interfaces


Rx7N D1 D2 D3 D4 D5 D6 D1 D2 D3 D4 D5 D6
D1 D2 D3 D4 D5 D6 Rx15N EG Tx16P Tx15N EG Rx16P

E1 is the same as on 120 HBMP-A


CHANNELS 5-8 E1 interfaces Rx7P C1 Rx5N EG Tx8N Tx7P EG Rx8N C6 C4 C5 C3 Tx6P Tx5N EG Rx6P C2 EG B1 B2 B3 B4 B5 B6 B1 B2 B3 B4 B5 B6
CHANNELS 13-16 E1 interfaces Rx13N C1 Rx15P EG C2 EG Tx14P C3 Tx16N Tx13N C4 Tx15P EG C5 EG Rx14P C6 Rx16N B1 B2 B3 B4 B5 B6

Rx3N EG Tx4P Tx3N EG Rx4P Rx5P EG Tx6N Tx5P EG Rx6N Rx9P EG Tx10N Tx9P EG Rx10N
Rx13P EG Tx14N Tx13P EG Rx14N

D1 D2 D3 D4 D5 D6

CHANNELS 1-4 E1 interfaces Rx1N Rx3P C1 EG EG C2 Tx4N C3 Tx2P Tx3P C4 Tx1N EG C5 EG Rx4N C6 Rx2P B1 B2 B3 B4 B5 B6 Rx1P EG Tx2N Tx1P EG Rx2N

A1 A2 A3 A4 A5 A6 A1 A2 A3 A4 A5 A6 A1 A2 A3 A4 A5 A6
A1 A2 A3 A4 A5 A6

and 75 HBMP-B. Four metral 24


EG Tx8_P Tx7N EG Rx8P Rx11N EG Tx12P Tx11N EG Rx12P

way (6x4) connectors are used on

front end containing each of them

four interfaces.

CHANNELS 9-12 E1 interfaces Rx11P C1 Rx9N EG C2 EG Tx12N C3 Tx10P Tx11P C4 Tx9N EG C5 EG Rx12N C6 Rx10P

48 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

PEIC

49 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

NEHC-C

It is based on the NEHC-B developed for the FR2.X practice introducing minor changes: back-plane

connectors, total PCB width 20 mm, and NLC bus extension.

In Alcatel Litespan 1540 FR3.0 case, the NEHC will have the NLC extension in the front-plate.

NEHCC board will perform the narrowband controller function when equipped in the MLS_3F subrack.

NEHCC will be inserted in slots 2 and 3 as shown in Fig. 3.

The differences between NEHC-B and NEHC-C boards are:

1.

NLC bus extension interface will be accessible through front plate instead of through HxMP plugs.

NLC bus extension interface will be accessible through two RJ-45 connectors placed at the front

plate. See Fig. 9.

2.

Network management interface and peer link interface have been swapped with respect to NEHC-

B board. For NEHC-C board, Network management interface will be implemented through FEC2

and peer link interface will be implemented through FEC1.

Rear connectors, in order to comply with the mechanichs of MLS-3F subrack.

50 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description
PIN SIGNAL NAME PIN SIGNAL NAME

NEHC-C
1 2 3 4 5 6 7 8 CKUP_PN DTUP_PP DTUP_PN CKUP_PP DTDN_PN 4 5 6 7 8 DTDN_PP 3 CKDN_PN 2 CKDN_PP 1 CKDN_PP CKDN_PN

To Upper Subtender RxTx

To Upper Subtender Clk

MODULE 1

MODULE 2

51 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

NSEC-C

The card is based on the previous NSEC-HS, It keeps the same functions of the old, including NLC bus

extension, former LEEP plug functionality.

The NSECC can be inserted in the same slots as the NEHC-C.

The NSECC performs these main functions:

51.84Mbps link interface using LVDS:

6x8.64 Mbps Narrow band Line Card (NLC) bus interface

NSECC redundancy management

Line Card disable/reset/presence detection management

Alarms collection

Inventory EEPROM management

Clock and synchronism drivers.

52 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

NSEC-C

A NSEC-C must receive a 51Mbps data stream from a NEHC-C in a main shelf subtending and forward it

to the next NSEC-C that in its turn must forward it to the next subtending and so on, following a

pointtopoint cascade architecture.

A NEHC-C can drive a maximum of 3 NSEC-C cascaded.

For protection reasons, a redundant NSEC-C must be provided in every MLS-3F shelf, i.e. the cascade

is doubled. One of the two NSECC's of a shelf is considered as MASTER, or active from

synchronization point of view; the other one is declared as SLAVE, or standby. Redundant

configuration for NSECC's in MLS shelf is considered a possible architecture, but a single not

redundant NSECC configuration is possible as well.

The two frontal LED's are complied with the following indications:

GREEN LED: as general internal failure, when this green LED is on, no internal alarms are present.

YELLOW LED: as active/standby status, when the yellow LED is on, the relevant NSEC-HS must be

considered in ACTIVE status. The other one must obviously have the LED off.

53 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

NSEC-C

M O D U LE 3 M O D U LE 4 M O D U LE 1 M O D U LE 2

54 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

ATLC-F

The ATLCF-48 is developed taking as reference latest design of ATLC-E card for Litespan with the only

functional difference of the higher number of channels to be handled, 48 i.s.o. 32 and the

physical changes related to the new equipment practice in which the board is to be used.

The ATLC-F fits 2 LED's on front plate. Functionality is:

Green led. When on, it indicates that operating voltages are present for correct board operation.

When off, one or more voltages are not generated on the board, so it is not operational.

Yellow led. It is turned on when at least 1 of the 48 subscriber terminals is active.

Front Panel Connector Pin-Out

Lines 1 to 16 on row a. Line 1, A wire, on pin a-1; Line 1, B wire, on pin a-2 and so on to

Line 16, A wire, on pin a-31 and Line 16, B wire, on pin a-32.

Lines 17 to 32 on row b. Line 17, A wire, on pin b-1; Line 17, B wire, on pin b-2 and so on

to Line 32, A wire, on pin b-31 and Line 32, B wire, on pin b-32.

Lines 33 to 48 on row c. Line 33, A wire, on pin c-1; Line 33, B wire, on pin c-2 and so on

to Line 48, A wire, on pin c-31 and Line 48, B wire, on pin c-32.
All Rights Reserved Alcatel-Lucent 2008, XXXXX

55 | Presentation Title | Month 2008

Boards description

ATLC-F

SUBSCRIBER 16

SUBSCRIBER 32

SUBSCRIBER 48

SUBSCRIBER 33

SUBSCRIBER 17

SUBSCRIBER 1

56 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

ATLC-3G

This is an additional 48 POTS line card variant. It is based on ATLC-F but introduces a simplified line

circuit version, VINETIC-4S instead of VINETIC-4C. Functions not supported by VINETIC-4S

regarding the ones in 4C are:

1.

Automatic Gain Control

2.

Adaptative Local Echo Cancellation

3.

Tone generation/detection

4.

DTMF generation/detection

5.

Configuration of Individual Gain Control and Impedance per line

Line testing and line configuration features are impacted by this reason.

For Led indicators, Pin-Out and Front Connector PIN-OUT see ATLC-F description

57 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

GIO3

Giga Ethernet Input/Output Card. This is a variant of LIOC card using the same switching than FR2

FESC card. It has in the front area GE interfaces to connect externally two VISC3-B cards, in order

to obtain in the same GE interface the NGN VoIP plus NM signals.

The functions or GIO3 are the same to those in LIOC, with a more sophisticated Ethernet switch, but

external input (T3 interface) and output (T4) for G.703 synchronization interface are lost in this

case. In the case of GIO3 equipment it should be equipped POW3 also, and the external E1

interfaces (of PEIC) are lost.

58 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

VIS3-B

The VIS3-B in Aneto is considered a reshaping of the current FR2 VISC-B card for NGN VoIP services .

Can be equipped in two specific slots in MLS-3F (L311ANE) or in four specific slots in MLS-3F4 variant.

The redundancy lines are integrated in the back-plane, including the simulation of VISP-A plug

presence. In the case of MLS-3F4 redundancy can be achieved for the first and for the second

pair of VIS3-B cards., it means that redundancy in these cards is by pairs, one VIS3-B is active and

the other the redundant in the first pair, and the same for the second pair of VIS3 cards. No Sw

impact is foreseen. At start-up VISC-B Sw will detect the VISP-A plug presence only if hot

switch-over is configured by operator and NEHC initializes the VISC-B in this mode; otherwise the

plug presence is not checked. The case of cold redundancy is fully driven by the NEHC, careless on

the plug presence. As conclusion, in case one only VISC-B is equipped (i.e. the peer VISC-B is not

present or a LT card is equipped in such position) no issue is expected although the simulated

VISP-A is present

59 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

EFL3

The EFL3 in Aneto is considered a reshaping of the current EFLC variants, keeping the same features

and modularity than in FR2, but just providing the line interfaces in the front plate of the FPBA.

The associated splitter card has to be redesigned as well. Besides some additional changes are

needed since some signals that were provided by backplane have to be internally strapped in the

card

The following are the variants of EFL3: POTS service with NB-BB splitter POTS service without NB-BB splitter ISDN-BA service with NB-BB splitter ISDN-BA service without NB-BB splitter

EFL3-A

EFL3-B

EFL3-I

EFL3-H

60 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

BAL3-G and BAL3-H

BAL3-G and BAL3-H in Aneto are considered a reshaping of the current BALC-G and BALC-H variants,

keeping the same modularity and functionality as provided in FR2, but providing the line

interfaces in the front plate of the PBAs. BAL3-G is for ISDN-BA with 2B1Q line code and BAL3-H is

for 4B3T line code

61 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Boards description

NIOC

Network Input Output interfaces Card. Provides redundancy for the network interfaces with the BB

controllers.

Distributes the following external interfaces:

Up to 4 x GE uplinks to/from both BB-CC positions

16 x E1 to/from LIOC position

62 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

4
All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

63 | Presentation Title | Month 2008

Operation and maintenance

MANAGEMENT OF THE 1540 LITESPAN ACCESS NODE

The access node is managed by either, locally

by means of a Craft Terminal, or remotely

managed by an Operations System.

As a general rule, all the input coming from the the access node

operator and accepted by the NE never

disappears,

as

configuration changes are saved in a non-

volatile memory to allow an automatic re-

configuration after a shutdown.

The Alcatel Litespan 1540 NE is able to recover or stable crosstemporary

from the

faulty

equipment

malfunctioning equipment. Such a recovery

is

required

for

connections, which are in set-up or release

phase.

64 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

NETWORK MANAGEMENT

The complete management solution is offered to support operations, administration and maintenance

activity of Alcatel Litespan 1540 access nodes. The Alcatel Litespan 1540 management complies with

general principles set in ITU-T M.3010 recommendation. It supports all the required functions for

fault, configuration, performance and security management.

The following management interfaces apply to the Alcatel Litespan 1540:

Between the NE (BB access part) and the Craft Terminal: TL/1 interface over RS232.

Between the NE (NB access part) and 1353 LMS: Q3 interface either over OSI (fully ETSI/ITU-T

based) or over IP.

Between the NE (BB access part) and ngAWS 5523: SNMP interface

The connection to the craft terminal is made trough the LIOC board located in the most left position of

the MLS_3F subrack

65 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

NETWORK POSITION OF THE LIOC IN THE MLS_3F SUBRACK

2 3

5 6 7

8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

PEIC

L E D 1 (G R E E N ) S1 X204

NEHC / NSEC NEHC / NSEC LIM / BB LIM / VISC LIM / BB LIM / VISC LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB GEBC LIM / BB LIM LIM / BB GEBC LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM

L E D 2 (Y E L L O W )

LIOC

X206

CRA FT T E R M IN A L CONECTOR
X205

X201 X202 X203

66 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

CRAFT TERMINAL CONNECTION

The CT (Access Craft Terminal) is a RS232C TCP/IP interface between the PC and the management access

unit denoted as LIOC. It is a 9600 b/s standard modem working at 34800 b/s with IP protocol (means

SLIP: Unix connection server type and Compatible NE2000 TCP/IP protocol). The CT has 192.0.0.2 as

the IP address while LIOC has 192.0.0.5 as the IP address.

The connector used is RJ11 on the front panel, and the signals are RXD_CT, TXD_CT, DTR_CT, CD,

DSR_CT and EG. The type is asynchronous, full duplex, 1 starts bit, 8 data, 1 parity programmable

bit, 1 stop bit, while the speed is Configurable and can be up to 9600 b/s. There is a RS232 receiver
PC serial / DB-9 1 (in) 3 (out) 2 (in) 5 4(out) 6 (in)

and transmitter used.

Signal

LIOC X204 / RJ11

CD

1 (out)

TXD

2 (in)

RXD

3 (out)

GND

DTR

5 (in)

DSR

6 (out)

RTS

CTS

7 (short connect with 8) 8 (short connect with 7)


All Rights Reserved Alcatel-Lucent 2008, XXXXX

67 | Presentation Title | Month 2008

Operation and maintenance

REMOTE MANAGEMENT

The Access part can be remotely managed by 1353DN application running in a workstation. The Access

part can be managed by Ethernet interface. Ethernet interface provides a LAN interface, in fact 10

base T, towards the LAN-TP connector of a workstation (with related RJ45 RJ45 ends cabling).

X206

MOUSE SERIAL 1

MOUS E

KEYBD SERIAL 2 LAN TP

68 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

STARTING THE NB CRAFT TERMINAL

Using the CT, the installer may change the default configuration (if not integrated system) or the factory

configuration (if integrated system), setting up the appropriate one for the site.

The CT of the NB part provides means for the handling of the management functionality.

The following functionality is covered:


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Equipment management

Port and termination provisioning


PEIC
X204

V5 and leased lines interface provisioning

Management communication configuration


LIOC
SERIAL
All Rights Reserved Alcatel-Lucent 2008, XXXXX

Alarm presentation

Line testing and loop backs

Software download

69 | Presentation Title | Month 2008

NEHC / NSEC NEHC / NSEC LIM / BB LIM / VISC LIM / BB LIM / VISC LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB GEBC LIM / BB LIM LIM / BB GEBC LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM

Connection configuration and set-up (V5.1 connections)

Operation and maintenance

STARTING NB-CT

The next steps must be followed:

1. - Connect physically the PC to the LIOC board

located in the NE.

2. - The communication between the Craft Terminal

(PC) and the Litespan NE has to be seen as a

modem connection. So, before starting the CT

application, it is necessary to make a telephone

connection

70 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

STARTING NB-CT

71 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

STARTING NB-CT

View Subrack Board Rack Subrack Board Timing Sources Access Control Q3Configuration Debugger Installation Data Display NE

Equipment

Administration

Refresh

Declare

Display

External input points

Request Release

Save configuration Restart communications Exit

Download configuration

Warm restart

Cold restart

Get Restart Info

SwitchOver

72 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

STARTING NB-CT

Sw management Network Interfaces Perform Progress List/Modify Declare

V.5 V5.1 V5.2 V5.1 V5.2 User Ports Declare V5.1 V5.2 List/Modify

Display, modify

Download

Backup and Restore

V5 Hub Declare List/Modify EU RU BAS Interfaces User Ports Network Interface

VoIP Declare List/Modify Declare List/Modify Declare List/Modify

Virtual UP

Hub Role

73 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

STARTING NB-CT

Leased Lines Declare List/Modify Configuration List Declare List/Modify RU Declare List/Modify PVC End Point User Ports Frame Relay Logical Port Declare List/Modify List/Modify Declare List/Modify User Ports List/Modify Declare List/Modify Network Interfaces Declare

Mirror

Network Interfaces

User Ports

Cross Connections

Testing

Configuration

Results

74 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

STARTING NB-CT

PM

Alarms

Help

Current Data

Configuration

Retrieve current

Index

Display

Log

Find

History Data

Display

About

75 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

STARTING NB-CT

76 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

SOFTWARE DOWNLOAD

The Software management menu, allows displaying and/or modifying the SW versions available at NEHC

board, showing the status of the SW downloading process if any. Other possible operation is to

download a new version (or edition) of software to the main boards of the system, from a remote

source (CT, OS or a server identified by an OSI address).

The NEHC board (where the software to be downloaded is targeted) has two banks of memory; therefore

it is possible to start downloading new software without disturbing traffic. Once the new software has

been downloaded (in the inactive bank of memory), it is possible to activate it (to copy to the

destination boards and to test if it works properly) and to commit it (to finish the operation, by

releasing the inactive bank of memory). If the test shows that it is not working properly, it is possible

to go back with the previous software, via the roll back option (if it is not yet committed). Please,

notice that for starting a downloading process, it is necessary to release the inactive bank of memory,

by deleting (if any) its software version.

77 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

EQUIPMENT CONFIGURATION

To declare any extended MLS in the Litespan-1540, select Equipment Declare Subrack.

The first field to fill is the number of the subrack. Select n for the Extended # [n-1] number.

The second field is the subrack type. It depends on previous subrack

An MLS-3F main subrack can only be extended with an MLS-3F.

78 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

UNIT DECLARATION

There are two ways to declare a unit, selecting Equipment Declare Board menu options or clicking

(right button) over the inserted unit

79 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

INTERFACE CONFIGURATION

The interface declaration is organized based on the type of interface for FR2: V5.1 or V5.2 interfaces (for

digital voice subscribers), Mirror interfaces (for analogue voice subscribers), Leased line interfaces

(for digital data subscribers), HDSL interfaces (for HDSL transport) and optical interfaces (for PDH 34

Mb/s optical transport).

The V5.2 interface is a standard protocol between a local exchange (LE) and an access node (AN). The

interface description can be found on ITU-T G.965 (or ETSI ETS 300 347-1). Each V5.2 interface can

have from 1 x 2048 Kb/s link (min) up to 16 x 2048 Kb/s links (max).

The interface characteristics are:

a) Each interface can have up to 16 links.

b) There are link protection (group 1) and channel protection (group 2).

c) The interface can manage POTS, ISDN BRA and ISDN PRA

d) It is designed for concentration (dynamic assignment of TS's).

80 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

INTERFACE CONFIGURATION

The V5.2 interface has traffic channels (bearer channels) and signalling channels (c-channels). The

signalling is divided into subscriber signalling and V5.2 interface signalling.

The subscriber signalling is divided into: One for all subscribers. P channels (X-25, SAPI=16) One for each subscriber. F channels (frame-relay, SAPI=32-62) One for each subscriber. D channels (BRA D16 PRA D64, SAPI16,32-62). One for each subscriber

a) PSTN

b) ISDN-p,

c) ISDN-f,

d) ISDN-D,

81 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

INTERFACE CONFIGURATION

Only are marked (Type) the primary and secondary links. The interface has a label (User label) and two

numbers, one of them (Interface Identifier) provided by the exchange and another for internal use

(Alcatel Itf Identifier) starting 1 and ending in the max number of interfaces. Each link belonging to

an interface is identified by an exchange number (2Mbps Id) and an internal number (2Mbps link

Number). A switching identifier number (Adjacent LE number) must be provided.

To define a V5.2 interface, select V5 Network Interfaces Declare V5.2:


Field User label Up to 14 capital/lowercase characters Value Notes

Adjacent LE From 0 to 2147483648 (numerical PTT value for LE value) Interface Id From 0 to 16777215 (numerical value) LE value for interface Alcatel Itf Id From 1 to 16/21 (numerical value) V5.2 variant It depends on LE (normally 0 or 1). Number Id LCC 2Mbps Link (Primary) TimeSlot (16) From 1 to 16/21 (numerical value) From 0 to 255 (numerical value) Litespan value for interface See NOTE 1 Litespan value for link (NEHC 02xx) LE value for link (G.965 sec 16.2.4.3.5) Only used by OS. PSTN signalling link (one per interface) PSTN signalling TS (one per interface)
All Rights Reserved Alcatel-Lucent 2008, XXXXX

82 | Presentation Title | Month 2008

Operation and maintenance

INTERFACE CONFIGURATION

Once declared, the V5.2 interface must be started up. To do that, once we get (V5 Network Interfaces

List/Modify V5.2) the list of V5.2 interfaces window, select the proper interface, click on mouse

right button and choose the start up option

83 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

INTERFACE CONFIGURATION

To define a V5.2 subscriber (user port), select V5 User Ports Declare V5.2
PSTN service Unit Board Port V5 interface Comm Path Link Num Comm Path TS 1-48 1-16 1 21 16, 15, 31 From 4 up to 23 ATLC-F/3G Notes Declared unit All MLS_3F type All ATLC-F/3G 16 if PDH

Direct Dialling PSTN Special Features Public Tel Private Meter Special Loop Res Security Line Others Address L3 (0-32767) Admin State Unlocked/Locked

Only for PSTN

L3 or L2 address For use: Unlocked

84 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

CONNECTIONS

These are the common connections between a user port and a network interface. This interface would be

associated to the NEHC port, external G.703 interface.

Select Leased Lines Cross Connections Declare.

85 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

SYNCHRONIZATION

The scope of this section is the timing sources (also denoted as clock sources) configuration.

To configure the extracted timing sources, from Main menu, select Admin Timing Sources

Configuration as shown

86 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Operation and maintenance

PDH SYSTEM SYNCHRONIZATION

The PDH Litespan has five timing sources: Two externals, two extracted and one internal. The external

ones are physically connected to LIOC.

The internal one is located in NEHC-C (64 KHz clock reference) and it is not configurable.

The extracted ones are configurable and timing sources are extracted from one and/or two G.703 2048

Kb/s links.

The timing sources must fulfill G.704 frequency accuracy (50 ppm) and jitter and wander must fulfill

G.736 and G.823 for proper operation. Litespan output clock has a frequency accuracy of 50 ppm.

Litespan intrinsic output jitter is less than 25 ns (measured in a 60 sec time interval and within frequency

range from 20Hz to 100KHz). Anyway, the output jitter is according G.823 option 1 (if extracted

source).

When system is working with external (or extracted) references, the operating mode is tracking mode.

Otherwise, if internal is used, the system has free running mode. If being used clock source fails, the

system search from highest to lowest priority source which is the first available (without failure)

source and switches to it. The system remains with selected source even a higher priority source

become available. That means, no switchover (except for free running mode).
All Rights Reserved Alcatel-Lucent 2008, XXXXX

87 | Presentation Title | Month 2008

Operation and maintenance

SYNCHRONIZATION

The scope of this section is the timing sources (also denoted as clock sources) configuration.

To configure the extracted timing sources, from Main menu, select Admin Timing Sources

Configuration as shown

88 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Future Furute evolution

LIOC PEIC ATLC-F ATLC-3G MLS_3F NEHC-C NSEC-C

89 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Future evolution

NIOC (ADM) GEB3-A GEB3-B ISDN SERVICE GIO3 VISCB NEW MLS_3F

90 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Future evolution NIOC (Network I/O Card)

This card should be plugged in special TT slot (always compatible with LIM)

Redundant configuration is possible


20 L I M V I S C N I O C A D M V I S C 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 25 L I M G E B C 20 L I M 25 L I M - G N E I B O C C A D M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 480

Width (mm) Card

30 L P I E O I C C

NB slot 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6

20 N E H C N S E C N B S C 2 3 5 6 7 8 7 7 7 8 8 8

20 N E H C N S E C N B S C 4

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Total slots 9 10 11 12 13 14 15 16 17 18 19 20 20 10 12 13 14 15 16 17 18 19 20 18 13 14 15 16 17 18 19 20 16

NB-only LIM numbering NB&BB w/o Xp LIM numbering NB&BB w Xp LIM numbering

91 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Future evolution ATM connectivity in 3F MLS

ATM Bridge card Subsystem for interfacing to ATM uplinks


STM1 IP2ATM 8xE1 2xE3

GEB3A IP to ATM conversion

Different Up-links physical interfaces


STM-1 8x E1-IMA

GEB3A ATM Bridge card

2 x E3

92 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Future evolution New MLS_3F

New MLS-3F variant to provide 4 slots suitable for VIS3B

Width (mm) Card

30 L P I E O I C C

20 20 20 20 20 20 20 20 20 20 25 20 25 20 20 20 20 20 20 20 20 20 N N L L L L L L L L L L L L L L L L L L L L E E I I I I I I I I I I I I I I I I I I I I H H M M M M M M M M M M M M M M M M M M M M C C - - - G - G N N E N E N S S B I B I E E C O C O VIS3B C C C C - A A D D M M

480

NB slot 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Total slots 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 20 1 2 3 4 5 6 7 8 10 12 13 14 15 16 17 18 19 20 18 1 2 3 4 5 6 7 8 13 14 15 16 17 18 19 20 16

NB-only LIM numbering NB&BB w/o Xp LIM numbering NB&BB w Xp LIM numbering

93 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

6
All Rights Reserved Alcatel-Lucent 2008, XXXXX

Practises

94 | Presentation Title | Month 2008

Practises

Litespan FR3.0 Tripple Play Boards Configuration GEB3 + EFLC + VISCB3

95 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

www.alcatel-lucent.com www.alcatel-lucent.com

96 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Potrebbero piacerti anche