Agenda
1. Whats new?
2. Equipment description
3. Boards description
5. Future evolution
6. Practises
1
All Rights Reserved Alcatel-Lucent 2008, XXXXX
Whats new?
Whats new?
New subrack MLS_3F has been introduced. This new subrack can be used either as MAIN subrack or as
EXTENSION subrack.
The Alcatel 1540 Litespan supports a variety of different scenarios. Different configurations of the
Subrack
Whats new?
Boards
New LIOC
LIOC (Local Input/Output Card). This board is used in the first position of MLS_3F subrack.
The board includes mainly the functions of outband Ethernet O&M, craft terminal, G.703
synchronization interface and external alarms collection. This card is based on previous FR2.X
Ethernet interface for the system and connections from every controller (NB, BB and ADM's)
allowing one only external O&M for all the system controller elements.
Craft Terminal.
Whats new?
Boards
PEIC
o 16 x E1 external interfaces.
NEHC-C
The Narrowband Element Handler Controller (NEHC) performs the narrowband controller function as
Network Element Controller in MLS subrack. This new NEHC-C PDH would be used only in PDH / TDM
applications. This new NEHC-C PDH do not support some functionality previously supported as:
Whats new?
Boards
NSEC
New Narrowband Shelf Extension Controller for the Alcatel Litespan FR3.0 system.
The card is based on the previous NSEC-HS. It keeps the same functions of the old, including NLC
The main difference between the two cards is the size. The NLC bus extension lines are located in a
ATLCF
It is a 48 subscribers POTS line card. The main impact of this new equipment practice in line cards is
that the access to subscriber lines is now performed through front-plate connector instead of rear
back-plane connectors.
ATL3G
It is a 48 subscribers POTS line card. The PBA-ATL3G-48 is developed as a functional variant of the
PBA-ATLCF-48 that uses Vinetic-4S codec instead of the Vinetic-4C used in the ATLCF; this has some
Whats new?
Boards
PEIC
o 16 x E1 external interfaces.
NEHC-C
The Narrowband Element Handler Controller (NEHC) performs the narrowband controller function as
Network Element Controller in MLS subrack. This new NEHC-C PDH would be used only in PDH / TDM
applications. This new NEHC-C PDH do not support some functionality previously supported as:
2
All Rights Reserved Alcatel-Lucent 2008, XXXXX
Equipment description
Equipment description
General
FE
VoIP Gateway
PDH NB Shelf Controller Transport Bus Internal BB Shelf Controller BB Line Card Test Card busses Litespan
SDH/PDH Transport
PDH
NB Line Card
Server Card
Ethernet Transport
FE, GE
3,840 2,556
MLS-3F
Mass-Market Multiservice
2,430
2,250
MLS-3F MLS-3F
MLS-3F
MLS-3F
Outdoor 2 MLS Indoor up to 4 MLS
2002
2003
2006
2007
Voice-intensive Applications
MLS
lee21
MLS-3F
MLS
lee21
MLS-3F MLS-3F
MLS-le
MLS MLS-hbe
MLS-hb Indoor up to 4 MLS Outdoor 2 MLS
MLS-le
MLS-hb
Indoor
up to
lee21
MLS-3F
Outdoor 2 MLS
MLS-3F
Indoor up to 4 MLS
Outdoor 2 MLS
Indoor up to 4 MLS
2556 POTS
1152 POTS
Equipment description
ATM Bus 155Mbps
Narrowband LIM
Buses
TDM Bus 51Mbps
Ethernet Controller
GE p2p links
STM-1/ IMA
ATM bridge
Narrowband Controller
Local E1 (16x)
Backpanel connections
External connections
Plug or connector
Equipment description
Same carrier grade TDM/NGN architecture with an increase of PSTN density to 48UP/card.
ATM
Narrowband Controller
Local E1 (16x)
VoIP Gateway Servers
Equipment description
Same BB-IP architecture of ISAM, not only in MLS-main but also in MLS extensions.
Ethernet Controller
GE p2p links
Equipment description
R3 architecture: ATM
ATM native bus (IQ bus) removed: ANETO is not ASAM inside since 155Mbps bus is limited for Triple-
Play deployment
Ethernet Controller
GE p2p links
Equipment description
R3 architecture: SDH
New integrated ADM for TDM and Ethernet (EoS) SDH transport capability into STM-1/4/16
TDM Bus 51Mbps
Ethernet Controller
GE p2p links
Narrowband LIM
ADM, SDH
STM-1/4/16
Narrowband Controller
New
Transmission
Local E1 (16x)
Equipment description
Terminals
Ethernet (FE/GE)
Ethernet Controller
STM-1/E3/E1
ATM Bridge
EFL3x 24 ADSL1/2/2+
3-Play non-blocking
STM-1/4
16xE1
ATL3x 48 POTS
Narrowband Controller
Commercial, 300-3,400 Hz
Ethernet (FE)
VoIP Server
BAL3x
16 ISDN NT
ISDN commercial
Equipment description
R3 architecture: MLS-3F
20 L I M V I S C N I O C A D M V I S C 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 20 L I M 480
I/O AUXILIARY
L I O C
30 P E I C
25 L I M G E B C
25 L I M G E B C
NB CTL/EXT
N I O C A D M
NB slot 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8
20 N E H C N S E C N B S C 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 9 10 11 12 13 14 15 16 17 18 19 20 10 12 13 14 15 16 17 18 19 20 13 14 15 16 17 18 19 20
20 N E H C N S E C N B S C 4
NB-only LIM numbering NB&BB w/o Xp LIM numbering NB&BB w Xp LIM numbering
Total slots 20 18 16
NB user ports NB 48 16 TBC max Shelf type NB type slots PSTN ISDN LL NB only TDM 20 960 320 NGN (VIS3B) 18 864 288 NB&BB (GEB3A) TDM 18 864 288 NGN (VIS3B) 16 768 256 NB&BB&TP TDM 16 768 256 NGN (VIS3B) 14 672 224
All Rights Reserved Alcatel-Lucent 2008, XXXXX
16 14 16 14
Equipment description
NB main
L I O C N E H C V I S C V I S C N E H C P E I C L L L L L L L L L L L L L L L L L L L L I I I I I I I I I I I I I I I I I I I I M M M M M M M M M M M M M M M M M M M M
L I O C N I O C A D M
P E I C
N E H C N S E C N B S C
N E H C N S E C N B S C
L L L L L L L L L I I I I I I I I I M M M M M M M M M G - E V V I I B S S C C C
L L I I M M - G N E I B O C C A D M
N B S C
N B S C
L I O C
P E I C
N E H C N S E C N B S C
N E H C N S E C N B S C
L L L L L L L L L L I I I I I I I I I I M M M M M M M M M M - G E V V B I I S S C C C
Equipment description
NB main is always the 1st shelf. All the rest are NB extensions
1st shelf
2nd shelf
NB
BB
ADM
NIOC
Equipment description
R3 architecture: cards
ATLC-E (32UP)
Equipment description
MLS-3F provides MDF cable access in the front plate of the boards, not in the back-plane
96p MDF cable (same MDF raw cable of 96p as FR2: 1AC-02319-0001): two slots connected by a
single cable.
Equipment description
Equipment description
Equipment description
Once MDF connector is extracted, card can be inserted extracted without difficulty
Equipment description
All cabling of POWP, HBMP and TAUP are moved into LIOC and PEIC cards MLS-3F I/O cabling
MLS-hb16 I/O solution in plug area PEIC Power E1s LIOC CT LAN Sync AUX NEHC/NSEC NLC ext
All Rights Reserved Alcatel-Lucent 2008, XXXXX
Equipment description
NEHCC Narrowband traffic Controller V5 signalling termination Network management interface with 1353 LMS System clock transmission for PDH transport systems Termination of HDLC for ISDN subscribers Master Database in non-volatile memory NSECC TDM bus and synchronism connection to Extension shelf Subtending interface for additional Extension shelves
IGMP snooping (version 3) DHCP relay option 82 Traffic prioritization in VLAN (802.1 p/q) Spanning Tree (RSTP)
Subtending GE Star
Uplink
2xGE electrical GE
-A B3
Cascading Options
B GE 3-A
Equipment description
2 x E3
Equipment description
Class 5 Replacement
Voice codecs: ITU-T G.711 (64 Kb/s) ITU-T G.729A (8 Kb/s) ITU-T G.723.1 (6,3 and 5,3 Kb/s) Echo cancellation ITU-T G.165 ITU-T G.168 Voice activity detection (VAD) Comfort noise generation (CNG) Packet loss concealment (PLC)
Equipment description
ATL3-G
48 customer lines 24 mA line current feeding ( 6 lines can deliver 40 mA, configurable by Z interface) Automatic reduction of line current during restricted batteries). Ring voltage and 12 kHz/16 kHz metering insertion Polarity reversal. Programmable cancellation Programmable gain level. Over voltage detection. Z interface adaptable to national specification on CDE basis Specification in accordance with ITU-T Recommendations Q.552, G.712 for interface Z
All Rights Reserved Alcatel-Lucent 2008, XXXXX
power
operation
(i.e.
backup
line
impedance
with
echo
protection
and
over
current
Equipment description
R3 architecture: New ISDN board variants for 3F MLS BAL3-G (2B1Q line code) BAL3-H (4B3T line code)
16 lines/board Integrated line testing
Remote power feeding for NT (feeding voltage at 70 V or 97 V) Feeding current up to 40 mA. OAM capability.
Embedded operation channel, allowing the following operations. Bit error rate, including repeater sections. Loop management. Detection of line errors (no start-up upon activation, loss of frame, etc.). Overcurrent detection in the power feeding system.
Equipment description
EFL3-B (POTS splitter-less) 24 MultiDSL ports (ADSL/2/2+) MAC and IP Packet forwarding PPPoE relay DHCP relay PPPoA to PPPoE relay IEEE 802.1x user authentification MultiDSL over ISDN (EFL3H version) Embedded splitters for POTS or ISDN
EFL3A version for POTS w Splitter EFL3I version for ISDN w Splitter
Equipment description
Ethernet / IP Network
ISP HSI
1540 Litespan
HSI xDSL
Video
Video
GEB3A
Invest now in revenue-generating services while preparing for the services of tomorrow.
EFL3-B
Equipment description
PEIC Powering unit PDH transport interfaces (16xE1) Shared slot with LIOC card
LIOC Shared slot with PEIC card Craft Terminal interface for Narrowband controller LAN interface for Qecc transport Auxiliary alarms and Top Rack Unit Synchronism functionality
Equipment description
L I O C
P E I C
L I O C
P E I C
N E H C -
N E H C -
L L L L L L L L L L L L L L L L L L L L I I I I I I I I I I I I I I I I I I I I M M M M M M M M M M M M M M M M M M M M
V I S C
V I S C
N B S C
N B S C
3
All Rights Reserved Alcatel-Lucent 2008, XXXXX
Boards description
Boards description
LIOC
The board includes mainly the functions of outband Ethernet O&M, craft terminal, G.703
The LIOC assumes the RI functions in MBTP and TAUP in the current MLS's. It places together the
information distributed in the current practice in TAUP and MBTP plugs in one only RI EPROM
accessible via IAB from NEHC. The IAB interface is used as well for communication of external alarms.
This card is based on previous FR2.X Litespan cards POWP, MBTP, TAUP, HBMPA and HBMPB. External
Ethernet interface for the system and connections from every controller (NB, BB and ADM's)
Craft Terminal.
G.703 synchronization interface. One external input (T3 interface) / One output (T4)
With new board PEIC is the local I/O card that resumes all the plugs used in Litespan FR2 TAUP, HBMP)
All Rights Reserved Alcatel-Lucent 2008, XXXXX
(POWP,
Boards description
LIOC
The board collects external alarms through the metral connectors X201, X202 and X203 as can be seen
in front panel from several external devices, which will be stored in the memory in CPLD. The NB
controller through the IAB bus will read these alarms. In the same way, several controls and
commands ordered by the NB controller are managed by the LIOC. This part of the LIOC is strongly
Boards description
LIOC
STATUS / LED All OFF (No alarm nor attention of alarms) All ON (URG and NURG alarms as well as Light attended) URG ON, rest OFF Flash URG OFF, rest ON NURG ON, rest OFF NURG OFF, rest ON ATTD ON, rest off ATTD OFF, rest on Dark Light Dark Light Switch1 On On Off Off Flash Light Dark Light Flash Flash Light Dark Switch2 On Off On Off Dark Dark LED1 (GREEN) LED2 (YELLOW)
L E D 1 (G R E E N )
L E D 2 (Y E L L O W )
S1
X204
C RA FT
X206
O&M
X205
C lo c k Im p u t
X201
X202
X203
Boards description
LIOC
Through a RS232 interface on the front panel the craft terminal is connected.
The connector used is RJ11 on the front panel, and the signals are RXD_CT, TXD_CT, DTR_CT, CD,
DSR_CT and EG. The type is asynchronous, full duplex, 1 starts bit, 8 data, 1 parity programmable bit,
1 stop bit, while the speed is Configurable and can be up to 9600 b/s. There is a RS232 receiver and
transmitter used.
The LIOC includes one external interface for the system. This interface is connected to an internal
switch in LIOC and the Aneto MLS provides connections from every controller (NB-CCs, BB-CCs and
ADM's) to that switch, allowing in the future one only external O&M for all the system controller
Outband ethernet lan connection for network management uses X206 connector
Boards description
LIOC
ETHERNET SWITCH
LIOC includes one simple Ethernet switch that provides from one side one common Ethernet interface
for outband management and on the other side control plane communication when needed (future
releases) among the NB, BB controllers and ADM slots. Differential interfaces (HCL type) are routed
from all these slots to the LIOC position, each one connected to a differential port in the switch.
An initial ARP has to be sent during start up by the master controller to guarantee that the MAC
Boards description
PEIC
This card is based on other Litespan cards POWPA, PATC, HBMPA and HBMPB.The PEIC is part of the
cards equipped on the subrack MLS_3F. The board is to be inserted face to face with LIOC card.
As it can be seen PEIC is plugged rotated 180 in relation with the usual plug orientation.
16 x E1 external interfaces from/to both NEHC's. The 16 x E1 are routed by backplane towards the
No presence wire is available for PEIC (on the other hand if such card is not present, no power feeding
Boards description
PEIC
POWER
POW ER CONNECTOR
FEED
INTERFACE
external
overcurrent /
shortcircuit
protection
should be provided at
rack/subrack level
Boards description
PEIC
E1 INTERFACES
Rx3N EG Tx4P Tx3N EG Rx4P Rx5P EG Tx6N Tx5P EG Rx6N Rx9P EG Tx10N Tx9P EG Rx10N
Rx13P EG Tx14N Tx13P EG Rx14N
D1 D2 D3 D4 D5 D6
CHANNELS 1-4 E1 interfaces Rx1N Rx3P C1 EG EG C2 Tx4N C3 Tx2P Tx3P C4 Tx1N EG C5 EG Rx4N C6 Rx2P B1 B2 B3 B4 B5 B6 Rx1P EG Tx2N Tx1P EG Rx2N
A1 A2 A3 A4 A5 A6 A1 A2 A3 A4 A5 A6 A1 A2 A3 A4 A5 A6
A1 A2 A3 A4 A5 A6
four interfaces.
CHANNELS 9-12 E1 interfaces Rx11P C1 Rx9N EG C2 EG Tx12N C3 Tx10P Tx11P C4 Tx9N EG C5 EG Rx12N C6 Rx10P
Boards description
PEIC
Boards description
NEHC-C
It is based on the NEHC-B developed for the FR2.X practice introducing minor changes: back-plane
In Alcatel Litespan 1540 FR3.0 case, the NEHC will have the NLC extension in the front-plate.
NEHCC board will perform the narrowband controller function when equipped in the MLS_3F subrack.
1.
NLC bus extension interface will be accessible through front plate instead of through HxMP plugs.
NLC bus extension interface will be accessible through two RJ-45 connectors placed at the front
2.
Network management interface and peer link interface have been swapped with respect to NEHC-
B board. For NEHC-C board, Network management interface will be implemented through FEC2
Boards description
PIN SIGNAL NAME PIN SIGNAL NAME
NEHC-C
1 2 3 4 5 6 7 8 CKUP_PN DTUP_PP DTUP_PN CKUP_PP DTDN_PN 4 5 6 7 8 DTDN_PP 3 CKDN_PN 2 CKDN_PP 1 CKDN_PP CKDN_PN
MODULE 1
MODULE 2
Boards description
NSEC-C
The card is based on the previous NSEC-HS, It keeps the same functions of the old, including NLC bus
Alarms collection
Boards description
NSEC-C
A NSEC-C must receive a 51Mbps data stream from a NEHC-C in a main shelf subtending and forward it
to the next NSEC-C that in its turn must forward it to the next subtending and so on, following a
For protection reasons, a redundant NSEC-C must be provided in every MLS-3F shelf, i.e. the cascade
is doubled. One of the two NSECC's of a shelf is considered as MASTER, or active from
synchronization point of view; the other one is declared as SLAVE, or standby. Redundant
configuration for NSECC's in MLS shelf is considered a possible architecture, but a single not
The two frontal LED's are complied with the following indications:
GREEN LED: as general internal failure, when this green LED is on, no internal alarms are present.
YELLOW LED: as active/standby status, when the yellow LED is on, the relevant NSEC-HS must be
considered in ACTIVE status. The other one must obviously have the LED off.
Boards description
NSEC-C
M O D U LE 3 M O D U LE 4 M O D U LE 1 M O D U LE 2
Boards description
ATLC-F
The ATLCF-48 is developed taking as reference latest design of ATLC-E card for Litespan with the only
functional difference of the higher number of channels to be handled, 48 i.s.o. 32 and the
physical changes related to the new equipment practice in which the board is to be used.
Green led. When on, it indicates that operating voltages are present for correct board operation.
When off, one or more voltages are not generated on the board, so it is not operational.
Lines 1 to 16 on row a. Line 1, A wire, on pin a-1; Line 1, B wire, on pin a-2 and so on to
Line 16, A wire, on pin a-31 and Line 16, B wire, on pin a-32.
Lines 17 to 32 on row b. Line 17, A wire, on pin b-1; Line 17, B wire, on pin b-2 and so on
to Line 32, A wire, on pin b-31 and Line 32, B wire, on pin b-32.
Lines 33 to 48 on row c. Line 33, A wire, on pin c-1; Line 33, B wire, on pin c-2 and so on
to Line 48, A wire, on pin c-31 and Line 48, B wire, on pin c-32.
All Rights Reserved Alcatel-Lucent 2008, XXXXX
Boards description
ATLC-F
SUBSCRIBER 16
SUBSCRIBER 32
SUBSCRIBER 48
SUBSCRIBER 33
SUBSCRIBER 17
SUBSCRIBER 1
Boards description
ATLC-3G
This is an additional 48 POTS line card variant. It is based on ATLC-F but introduces a simplified line
1.
2.
3.
Tone generation/detection
4.
DTMF generation/detection
5.
Line testing and line configuration features are impacted by this reason.
For Led indicators, Pin-Out and Front Connector PIN-OUT see ATLC-F description
Boards description
GIO3
Giga Ethernet Input/Output Card. This is a variant of LIOC card using the same switching than FR2
FESC card. It has in the front area GE interfaces to connect externally two VISC3-B cards, in order
The functions or GIO3 are the same to those in LIOC, with a more sophisticated Ethernet switch, but
external input (T3 interface) and output (T4) for G.703 synchronization interface are lost in this
case. In the case of GIO3 equipment it should be equipped POW3 also, and the external E1
Boards description
VIS3-B
The VIS3-B in Aneto is considered a reshaping of the current FR2 VISC-B card for NGN VoIP services .
Can be equipped in two specific slots in MLS-3F (L311ANE) or in four specific slots in MLS-3F4 variant.
The redundancy lines are integrated in the back-plane, including the simulation of VISP-A plug
presence. In the case of MLS-3F4 redundancy can be achieved for the first and for the second
pair of VIS3-B cards., it means that redundancy in these cards is by pairs, one VIS3-B is active and
the other the redundant in the first pair, and the same for the second pair of VIS3 cards. No Sw
impact is foreseen. At start-up VISC-B Sw will detect the VISP-A plug presence only if hot
switch-over is configured by operator and NEHC initializes the VISC-B in this mode; otherwise the
plug presence is not checked. The case of cold redundancy is fully driven by the NEHC, careless on
the plug presence. As conclusion, in case one only VISC-B is equipped (i.e. the peer VISC-B is not
present or a LT card is equipped in such position) no issue is expected although the simulated
VISP-A is present
Boards description
EFL3
The EFL3 in Aneto is considered a reshaping of the current EFLC variants, keeping the same features
and modularity than in FR2, but just providing the line interfaces in the front plate of the FPBA.
The associated splitter card has to be redesigned as well. Besides some additional changes are
needed since some signals that were provided by backplane have to be internally strapped in the
card
The following are the variants of EFL3: POTS service with NB-BB splitter POTS service without NB-BB splitter ISDN-BA service with NB-BB splitter ISDN-BA service without NB-BB splitter
EFL3-A
EFL3-B
EFL3-I
EFL3-H
Boards description
BAL3-G and BAL3-H in Aneto are considered a reshaping of the current BALC-G and BALC-H variants,
keeping the same modularity and functionality as provided in FR2, but providing the line
interfaces in the front plate of the PBAs. BAL3-G is for ISDN-BA with 2B1Q line code and BAL3-H is
Boards description
NIOC
Network Input Output interfaces Card. Provides redundancy for the network interfaces with the BB
controllers.
4
All Rights Reserved Alcatel-Lucent 2008, XXXXX
As a general rule, all the input coming from the the access node
disappears,
as
from the
faulty
equipment
is
required
for
phase.
NETWORK MANAGEMENT
The complete management solution is offered to support operations, administration and maintenance
activity of Alcatel Litespan 1540 access nodes. The Alcatel Litespan 1540 management complies with
general principles set in ITU-T M.3010 recommendation. It supports all the required functions for
Between the NE (BB access part) and the Craft Terminal: TL/1 interface over RS232.
Between the NE (NB access part) and 1353 LMS: Q3 interface either over OSI (fully ETSI/ITU-T
Between the NE (BB access part) and ngAWS 5523: SNMP interface
The connection to the craft terminal is made trough the LIOC board located in the most left position of
2 3
5 6 7
8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
PEIC
L E D 1 (G R E E N ) S1 X204
NEHC / NSEC NEHC / NSEC LIM / BB LIM / VISC LIM / BB LIM / VISC LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB GEBC LIM / BB LIM LIM / BB GEBC LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM
L E D 2 (Y E L L O W )
LIOC
X206
CRA FT T E R M IN A L CONECTOR
X205
The CT (Access Craft Terminal) is a RS232C TCP/IP interface between the PC and the management access
unit denoted as LIOC. It is a 9600 b/s standard modem working at 34800 b/s with IP protocol (means
SLIP: Unix connection server type and Compatible NE2000 TCP/IP protocol). The CT has 192.0.0.2 as
The connector used is RJ11 on the front panel, and the signals are RXD_CT, TXD_CT, DTR_CT, CD,
DSR_CT and EG. The type is asynchronous, full duplex, 1 starts bit, 8 data, 1 parity programmable
bit, 1 stop bit, while the speed is Configurable and can be up to 9600 b/s. There is a RS232 receiver
PC serial / DB-9 1 (in) 3 (out) 2 (in) 5 4(out) 6 (in)
Signal
CD
1 (out)
TXD
2 (in)
RXD
3 (out)
GND
DTR
5 (in)
DSR
6 (out)
RTS
CTS
REMOTE MANAGEMENT
The Access part can be remotely managed by 1353DN application running in a workstation. The Access
part can be managed by Ethernet interface. Ethernet interface provides a LAN interface, in fact 10
base T, towards the LAN-TP connector of a workstation (with related RJ45 RJ45 ends cabling).
X206
MOUSE SERIAL 1
MOUS E
Using the CT, the installer may change the default configuration (if not integrated system) or the factory
configuration (if integrated system), setting up the appropriate one for the site.
The CT of the NB part provides means for the handling of the management functionality.
Equipment management
Alarm presentation
Software download
NEHC / NSEC NEHC / NSEC LIM / BB LIM / VISC LIM / BB LIM / VISC LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB GEBC LIM / BB LIM LIM / BB GEBC LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM LIM / BB LIM
STARTING NB-CT
connection
STARTING NB-CT
STARTING NB-CT
View Subrack Board Rack Subrack Board Timing Sources Access Control Q3Configuration Debugger Installation Data Display NE
Equipment
Administration
Refresh
Declare
Display
Request Release
Download configuration
Warm restart
Cold restart
SwitchOver
STARTING NB-CT
V.5 V5.1 V5.2 V5.1 V5.2 User Ports Declare V5.1 V5.2 List/Modify
Display, modify
Download
Virtual UP
Hub Role
STARTING NB-CT
Leased Lines Declare List/Modify Configuration List Declare List/Modify RU Declare List/Modify PVC End Point User Ports Frame Relay Logical Port Declare List/Modify List/Modify Declare List/Modify User Ports List/Modify Declare List/Modify Network Interfaces Declare
Mirror
Network Interfaces
User Ports
Cross Connections
Testing
Configuration
Results
STARTING NB-CT
PM
Alarms
Help
Current Data
Configuration
Retrieve current
Index
Display
Log
Find
History Data
Display
About
STARTING NB-CT
SOFTWARE DOWNLOAD
The Software management menu, allows displaying and/or modifying the SW versions available at NEHC
board, showing the status of the SW downloading process if any. Other possible operation is to
download a new version (or edition) of software to the main boards of the system, from a remote
The NEHC board (where the software to be downloaded is targeted) has two banks of memory; therefore
it is possible to start downloading new software without disturbing traffic. Once the new software has
been downloaded (in the inactive bank of memory), it is possible to activate it (to copy to the
destination boards and to test if it works properly) and to commit it (to finish the operation, by
releasing the inactive bank of memory). If the test shows that it is not working properly, it is possible
to go back with the previous software, via the roll back option (if it is not yet committed). Please,
notice that for starting a downloading process, it is necessary to release the inactive bank of memory,
EQUIPMENT CONFIGURATION
To declare any extended MLS in the Litespan-1540, select Equipment Declare Subrack.
The first field to fill is the number of the subrack. Select n for the Extended # [n-1] number.
UNIT DECLARATION
There are two ways to declare a unit, selecting Equipment Declare Board menu options or clicking
INTERFACE CONFIGURATION
The interface declaration is organized based on the type of interface for FR2: V5.1 or V5.2 interfaces (for
digital voice subscribers), Mirror interfaces (for analogue voice subscribers), Leased line interfaces
(for digital data subscribers), HDSL interfaces (for HDSL transport) and optical interfaces (for PDH 34
The V5.2 interface is a standard protocol between a local exchange (LE) and an access node (AN). The
interface description can be found on ITU-T G.965 (or ETSI ETS 300 347-1). Each V5.2 interface can
have from 1 x 2048 Kb/s link (min) up to 16 x 2048 Kb/s links (max).
b) There are link protection (group 1) and channel protection (group 2).
c) The interface can manage POTS, ISDN BRA and ISDN PRA
INTERFACE CONFIGURATION
The V5.2 interface has traffic channels (bearer channels) and signalling channels (c-channels). The
The subscriber signalling is divided into: One for all subscribers. P channels (X-25, SAPI=16) One for each subscriber. F channels (frame-relay, SAPI=32-62) One for each subscriber. D channels (BRA D16 PRA D64, SAPI16,32-62). One for each subscriber
a) PSTN
b) ISDN-p,
c) ISDN-f,
d) ISDN-D,
INTERFACE CONFIGURATION
Only are marked (Type) the primary and secondary links. The interface has a label (User label) and two
numbers, one of them (Interface Identifier) provided by the exchange and another for internal use
(Alcatel Itf Identifier) starting 1 and ending in the max number of interfaces. Each link belonging to
an interface is identified by an exchange number (2Mbps Id) and an internal number (2Mbps link
Adjacent LE From 0 to 2147483648 (numerical PTT value for LE value) Interface Id From 0 to 16777215 (numerical value) LE value for interface Alcatel Itf Id From 1 to 16/21 (numerical value) V5.2 variant It depends on LE (normally 0 or 1). Number Id LCC 2Mbps Link (Primary) TimeSlot (16) From 1 to 16/21 (numerical value) From 0 to 255 (numerical value) Litespan value for interface See NOTE 1 Litespan value for link (NEHC 02xx) LE value for link (G.965 sec 16.2.4.3.5) Only used by OS. PSTN signalling link (one per interface) PSTN signalling TS (one per interface)
All Rights Reserved Alcatel-Lucent 2008, XXXXX
INTERFACE CONFIGURATION
Once declared, the V5.2 interface must be started up. To do that, once we get (V5 Network Interfaces
List/Modify V5.2) the list of V5.2 interfaces window, select the proper interface, click on mouse
INTERFACE CONFIGURATION
To define a V5.2 subscriber (user port), select V5 User Ports Declare V5.2
PSTN service Unit Board Port V5 interface Comm Path Link Num Comm Path TS 1-48 1-16 1 21 16, 15, 31 From 4 up to 23 ATLC-F/3G Notes Declared unit All MLS_3F type All ATLC-F/3G 16 if PDH
Direct Dialling PSTN Special Features Public Tel Private Meter Special Loop Res Security Line Others Address L3 (0-32767) Admin State Unlocked/Locked
CONNECTIONS
These are the common connections between a user port and a network interface. This interface would be
SYNCHRONIZATION
The scope of this section is the timing sources (also denoted as clock sources) configuration.
To configure the extracted timing sources, from Main menu, select Admin Timing Sources
Configuration as shown
The PDH Litespan has five timing sources: Two externals, two extracted and one internal. The external
The internal one is located in NEHC-C (64 KHz clock reference) and it is not configurable.
The extracted ones are configurable and timing sources are extracted from one and/or two G.703 2048
Kb/s links.
The timing sources must fulfill G.704 frequency accuracy (50 ppm) and jitter and wander must fulfill
G.736 and G.823 for proper operation. Litespan output clock has a frequency accuracy of 50 ppm.
Litespan intrinsic output jitter is less than 25 ns (measured in a 60 sec time interval and within frequency
range from 20Hz to 100KHz). Anyway, the output jitter is according G.823 option 1 (if extracted
source).
When system is working with external (or extracted) references, the operating mode is tracking mode.
Otherwise, if internal is used, the system has free running mode. If being used clock source fails, the
system search from highest to lowest priority source which is the first available (without failure)
source and switches to it. The system remains with selected source even a higher priority source
become available. That means, no switchover (except for free running mode).
All Rights Reserved Alcatel-Lucent 2008, XXXXX
SYNCHRONIZATION
The scope of this section is the timing sources (also denoted as clock sources) configuration.
To configure the extracted timing sources, from Main menu, select Admin Timing Sources
Configuration as shown
Future evolution
NIOC (ADM) GEB3-A GEB3-B ISDN SERVICE GIO3 VISCB NEW MLS_3F
This card should be plugged in special TT slot (always compatible with LIM)
30 L P I E O I C C
NB slot 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6
20 N E H C N S E C N B S C 2 3 5 6 7 8 7 7 7 8 8 8
20 N E H C N S E C N B S C 4
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Total slots 9 10 11 12 13 14 15 16 17 18 19 20 20 10 12 13 14 15 16 17 18 19 20 18 13 14 15 16 17 18 19 20 16
NB-only LIM numbering NB&BB w/o Xp LIM numbering NB&BB w Xp LIM numbering
2 x E3
30 L P I E O I C C
20 20 20 20 20 20 20 20 20 20 25 20 25 20 20 20 20 20 20 20 20 20 N N L L L L L L L L L L L L L L L L L L L L E E I I I I I I I I I I I I I I I I I I I I H H M M M M M M M M M M M M M M M M M M M M C C - - - G - G N N E N E N S S B I B I E E C O C O VIS3B C C C C - A A D D M M
480
NB-only LIM numbering NB&BB w/o Xp LIM numbering NB&BB w Xp LIM numbering
6
All Rights Reserved Alcatel-Lucent 2008, XXXXX
Practises
Practises