Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Mallikarjuna
TURBINE
10
I II III IV
(1-m1-m2-m3)
BOILER 11 m1 12 m2 13 m3 14
PUMP 7 5 3
8 6 4
9
7 5
(m1+m2) x 2 1
m1
(m1+m2+m3) 3
PUMP
2
Fig.5.9(a). Three stage regenerative cycle
1 kg
9 10
8 m1
(1-m1)
7 11
T 6 m1+m2
(1-m1-m2)
5 12
4 (m1+m2+m3) (1-m1-m2-m3)
3 13
2
1 (1-m1-m2-m3)
kg 1 14
Above figure shows an arrangement in which there are 3 stages of feed water heating
employing closed heaters. Steam to the 1st, 2nd and 3rd heaters is supplied at states 11,
12 and 13 respectively. The feed water leaving each heater is at the saturation
temperature corresponding to the pressure of bled steam supplied to that heater. The
Considering one kg of steam leaving the boiler and entering the turbine at state 10.
m1 (h11 - h 7 ) = (h 7 - h 6 ) ≈ (h 7 - h 5 )
(h 7 - h 5 )
m1 =
(h11 - h 7 )
m 2 (h12 - h 5 ) = (h 5 - h 4 ) + m1 (h 5 - h 7 )
(h 5 - h 3 ) - m1 (h 7 - h 5 )
m2 = ; Q (h 4 ≈ h 3 )
(h12 - h 5 )
m3 h13 + (m1 + m 2 )h 5 + (1 - m1 - m 2 - m3 )h 2 = h 3
(h 3 - h1 ) - (m1 + m 2 )(h 5 - h1 )
m3 =
(h13 - h1 )