Sei sulla pagina 1di 26

www.huawei.

com
Security Level: nternal Use
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential
LTE eNdoeB V2.1
Commissioning for M1
LTE Training Team
2011-05
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 2
n compIetion of this course, you shouId be abIe to:
now the way to do the commissioning with USB
now the commissioning procedure
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 3
a) Get USB Stick >256MB (Recommended modeIs: Netac U208, Netac
U180, Netac U215, and Netac U210)
b) The USB storage device has no additionaI function. The additionaI
functions incIude but are not Iimited to encryption, antivirus, bootstrap,
MP3, MP4, and smart mobiIe phone.
c) When you save the eNodeB software and data configuration fiIe to the
USB storage device, ensure that the Iocking switch on the USB storage
device is disabIed.
d) eNodeB software is copied to USB:/eNodeB/software/ (Software is
aIready stored on the USB Stick for Subcontractors)
Preparation before going to the site
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 4
Preparation before going to the site
d) eNodeB software is copied to USB:/eNodeB/software/ (Software is
aIready stored on the USB Stick for Subcontractors)
e) Subcontractor wiII get eNodeB configuration script and PreInfo.xmI from
Huawei engineer and then copy it to USB directory : /eNodeB/
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 5
Preparation before going to the site
The USB finaI directory structure Iooks Iike this
Note: The name of the configuration file must be CFGDATA.xml
Please verify the eNodeB ID and Name by opening the CFG file before
the Commissioning (right-click on file and select edit)!!!
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 6
Software&Configuration FiIe
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 7
Software&Configuration FiIe
a) Ensure that RRU has been aIready powered on and connected with
BBU by CPRI fiber cabIe. Check eNodeB hardware and make sure that the
LED Iight is normaI.
$9,9:8
RUN LED on each board in the BBU Blinking (ON Ior 1s and OFF Ior 1s)
Status oI the ALM LEDs on the LMPT,
LBBP, UTRP
OFF
STATE LED on the FAN oI the BBU3900 Blinking (green, ON Ior 1s and OFF Ior
1s)
CPRI LED on the LBBP ON (green)
VSWR LED on the RRU or LRFU OFF
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 8
nsert the USB disk into the USB port on the LMPT of the BBU3900.
Power on the eNodeB
After the eNodeB is started, it automatically upgrades the software and
download the data configuration file.
LED wiII be fIashing fast on both USB and LMPT board (RUN).
After about 20 minutes, check the status of the LED on the USB disk.
LED being red for Iong means the upgrade succeeds.
After Checking the Status of LEDs and ensuring that the eNodeB is running
properly,
Unplug the USB disk.
Software Upgrading and Data Configuration
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 9
Reference: LED status of the common fauIts
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 10
eNodeB Commissioning Tasks
(Subcontractor/Huawei Engineer)
Connection of PC/Laptop to eNodeB
a) Connect PC to eNodeb ETH port with Ethernet cabIe
b) Change IP settings of Laptop as seen beIow & disabIe any proxy server
settings
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 11
eNodeB Commissioning Tasks
(Subcontractor/Huawei Engineer)
b) Change IP settings of Laptop as seen beIow & disabIe any proxy server
settings
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 12
eNodeB Commissioning Tasks
(Subcontractor/Huawei Engineer)
c) Ping defauIt eNodeB IP address "192.168.0.49" for IocaI connection
See beIow a successfuI connection
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 13
eNodeB Commissioning Tasks
(Subcontractor/Huawei Engineer)
d) pen Internet ExpIorer and type in "192.168.0.49" to Iogin to eNodeB
Username:admin // Password:admin123
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 14
eNodeB Commissioning Tasks
(Subcontractor/Huawei Engineer)
d) pen SFTP tooI
Then set the FTP server setting in your laptop.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 15
eNodeB Commissioning Tasks
(Subcontractor/Huawei Engineer)
e) CIick "". If this message appears during the WebLMT Start, a Software
SuppIement needs to be done
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 16
eNodeB Commissioning Tasks
(Subcontractor/Huawei Engineer)
SuppIement Software
a) Check Software Version (LST VER:;)
Updated Software Version has to be V100R003C00SPC300.
b) Check Software Areas (LST SOFTWARE:;) -Main Area is the active Software
Area
c) activate the SFTP server.
d) Supplement Software ( SPL SOFTWARE) Supplement Software can be done
remotely via M2000 or locally via WebLMT, it will take approx.5-15Min.
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 17
eNodeB Commissioning Tasks
(Subcontractor/Huawei Engineer)
FTP Server Directory Name could be the Folder of the USB Stick
USB:/eNodeB/software/ or a folder on the Laptop with the Software files.
User Password:admin
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 18
eNodeB Commissioning Tasks
(Subcontractor/Huawei Engineer)
e) Check SuppIement Software Progress (Progress needs to be 100%)
f) pen Internet ExpIorer and type in "192.168.0.49" to re-Iogin to eNodeB
again Username:admin Password:admin123
*Notes: f you are prompted to change the password, please change to
"Enodeb123"
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 19
eNodeB Commissioning Tasks
(Subcontractor/Huawei Engineer)
InstaII New Iicense
List Iicense by typing "LST LICENSE".
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 20
eNodeB Status Check
5.1 Hardware & CeII Status
a) DispIay Board Information. (DSP BRD:;) - //onIy 1 LBBPc Board in SIot 3
wiII be used, aII additionaI LBBPc Boards need to be removed and
returned to Huawei
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 21
eNodeB Status Check
b) DispIay pticaI Port Informations (DSP CPRIPRT:;)
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 22
eNodeB Status Check
e) Check RRU (LST RRU:;)
d) Check Cell Status (DSP CELL:;)
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 23
eNodeB Status Check
e) Check Active Alarms via MML command (LST ALMAF:;) , there
should be no active alarm.
f) Check Active Alarms by clicking on Alarm Tab, then Engineering
should be the same alarm status as in alarm list)
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 24
Backup the eNodeB Configuration FiIe
a) Backup the eNodeB Configuration File (BP CFGFILE:;) only
LMT.xml will be updated
HUAWE TECHNOLOGES Co., Ltd. HUAWE Confidential Page 25
Backup the eNodeB Configuration FiIe
a) Backup the eNodeB Configuration File (BP CFGFILE:;) only
LMT.DBS will be updated
Thank You
www.huawei.com