Sei sulla pagina 1di 47

Table of Contents

Table of Contents .................................................................................................................................... 1


How to use this document ....................................................................................................................... 2
Abstract objects ...................................................................................................................................... 3
Clock ....................................................................................................................................................... 5
Time Of Use............................................................................................................................................. 6
Billing reset ............................................................................................................................................. 6
Disconnection ......................................................................................................................................... 8
Errors and Alarms .................................................................................................................................. 10
Event logs .............................................................................................................................................. 11
Firmware – upgrade and versioning....................................................................................................... 15
Energy registration - totals .................................................................................................................... 17
Energy registration – rates..................................................................................................................... 18
Demand registration.............................................................................................................................. 22
Profiles .................................................................................................................................................. 30
Power quality ........................................................................................................................................ 32
Multi Utility – Wired M-Bus single slave ................................................................................................ 37
Communication – setup and statistics ................................................................................................... 43

Page 1 of 47
How to use this document

This document describes the objects with attributes and methods which must be supported in order to
achieve interoperability at metering point with installed PLC node.

Object name IC version Logical Name Access Rights for all three clients
defined
1 attribute_1 type of attr._1 default value of attr._1 access_rights to attr._1
2 attribute_2 type of attr._2 default value of attr._2 access_rights to attr._2

1 method_1 type of data for meth._1 default value of access_rights to meth._1


meth._2

The default values are set only where necessary to achieve interoperability.

List of Abbreviations used:

IC Interface Class; used to identify the COSEM interface class and its version

--/S/G/A/GS Access rights definition; “--“ for no access, “S” for Set only, “G” for Get only, “A” for
action and “GS” for Get and Set access

Page 2 of 47
Abstract objects

SAP Assignment IC17-0 0-0:41.0.0.255 Access Rights T1


(Client 16/102/1)
1 logical_name octet-string[6] 0000290000FF G/-/G
2 SAP_assignment_list asslist_type {1,00002A0000FF} G/-/G

Current association IC15-1 0- Access Rights T2


0:40.0.0.255 (Client 16/102/1)
1 logical_name octet-string[6] 0000280000F G/-/G
F
2 object_list object_list_type G/-/G
3 associated_partners_id associated_partners_ty G/-/G
pe
4 application_context_name application_context_na G/-/G
me
5 xDLMS_context_info xDLMS_context_type G/-/G
6 authentication_mechanism_name mechanism_name G/-/G
7 secret octet-string[8] -/-/-1
8 association_status enum G/-/G
9 security_setup_reference octet-string 00002B0000F G/-/G
F

COSEM logical device name IC1-0 0-0:42.0.0.255 Access Rights T3


(Client 16/102/1)
1 logical_name octet-string[6] 00002A0000FF G/-/G
2 value octet-string[0... G/-/G

1
Change of password is proprietary and has to be documented by every meter manufacturer

Page 3 of 47
16]

Device ID 1, manufacturing number IC1-0 0-0:96.1.0.255 Access Rights T4


(Client 16/102/1)
1 logical_name octet-string[6] 0000600100FF -/-/G
2 value octet- -/-/G
string[0...16]

Device ID 2, utility number IC1-0 0-0:96.1.1.255 Access Rights T5


(Client 16/102/1)
1 logical_name octet-string[6] 0000600101FF -/-/G
2 value octet- -/-/GS
string[0...48]

Device ID 3 IC1-0 0-0:96.1.2.255 Access Rights T6


(Client 16/102/1)
1 logical_name octet-string[6] 0000600102FF -/-/G
2 value octet- -/-/GS
string[0...48]

Device ID 4 IC1-0 0-0:96.1.3.255 Access Rights T7


(Client 16/102/1)
1 logical_name octet-string[6] 0000600103FF -/-/G
2 value octet- -/-/GS
string[0...48]

Device ID 5 IC1-0 0-0:96.1.4.255 Access Rights T8

Page 4 of 47
(Client 16/102/1)
1 logical_name octet-string[6] 0000600104FF -/-/G
2 value octet- -/-/GS
string[0...48]

Clock

Clock IC8-0 0-0:1.0.0.255 Access Rights T9


(Client 16/102/1)
1 logical_name octet-string[6] 0000010000FF -/-/G
2 time octet-string[12]
-/S/GS
3 time_zone long 60 -/S/GS
4 status unsigned -/-/G
5 daylights_savings_begin octet-string[12] last sunday in
March at 02:00 -/S/GS
6 daylights_savings_end octet-string[12] last sunday in
October at 03:00 -/S/GS
7 daylights_savings_deviation integer 60 -/S/GS
8 daylights_savings_enabled boolean -/S/GS
9 clock_base enum 1 -/-/G

Clock Time Shift Limit IC3-0 1-0:0.9.11.255 Access Rights T10


(Client 16/102/1)
1 logical_name octet-string[6] 010000090BFF -/-/G
2 value unsigned 60 -/S/GS
3 scaler_unit scal_unit_type {0,7} -/-/G

Page 5 of 47
Time Of Use

Activity Calendar IC20-0 0-0:13.0.0.255 Access Rights T11


(Client 16/102/1)
1 logical_name octet-string[6] 00000D0000FF -/-/G
2 calendar_name_active octet-string[8] -/-/G
3 season_profile_active array[4] -/-/G
4 week_profile_table_active array[4] -/-/G
5 day_profile_table_active array[4] -/-/G
6 calendar_name_passive octet-string[8] -/S/GS
7 season_profile_passive array[4] -/S/GS
8 week_profile_table_passive array[4] -/S/GS
9 day_profile_table_passive array[4] -/S/GS
10 activate_passive_calendar_time octet-string[12] -/S/GS

Special Days Table IC11-0 0-0:11.0.0.255 Access Rights T12


(Client 16/102/1)
1 logical_name octet-string[6] 00000B0000FF -/-/G
2 entries array[30] -/S/GS

Billing reset

Predefined Scripts - MDI reset / end of billing IC9-0 0-0:10.0.1.255 Access Rights T13
period (Client 16/102/1)
1 logical_name octet-string[6] 00000A0001FF -/-/G
2 scripts script -- -/-/-

Page 6 of 47
1 execute long-unsigned 1
-/-/A

End of billing period 1 scheduler IC22-0 0-0:15.0.0.255 Access Rights T14


(Client 16/102/1)
1 logical_name octet-string[6] 00000F0000FF -/-/G
2 executed_script script {0-0:10.0.1.255,1} -/-/G
3 type enum 1 -/-/G

4 execution_time array[1] {"00000000";"FFFFFF01FF -/-/GS


"}2

Data of billing period 1 IC7-1 0-0:98.1.0.255 Access Rights T15


(Client 16/102/1)
1 logical_name octet-string[6] 0000620100FF -/-/G
2 buffer array -/-/G
3 capture_objects array[1…n] { -/-/GS
{8,0-
0:1.0.0.255,2,0};
{3,1-
0:1.8.1.255,2,0};
{3,1-0:1.8.2.255,2,0}
{3,1-
0:1.8.3.255,2,0};
{3,1-0:1.8.4.255,2,0}
}
4 capture_period double-long-unsigned 0 -/-/G
5 sort_method enum 1 -/-/G

2
Every day or every month

Page 7 of 47
6 sort_object capture_object_definiti none -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥13 -/-/G

1 reset integer -/-/A

Disconnection

Disconnect control scheduler IC22-0 0-0:15.0.1.255 Access Rights T16


(Client 16/102/1)
1 logical_name octet-string[6] 00000F0001FF -/-/G
2 executed_script script {0- -/-/GS
0:10.0.106.255;x}
3 type enum 1 -/-/G
4 execution_time array[1] -/-/GS

Disconnector script table IC9-0 0-0:10.0.106.255 Access Rights T17


(Client 16/102/1)
1 logical_name octet-string[6] 00000A006AFF -/-/G
2 scripts array[2] { -/-/G
{1,{2,70, 0-
0:96.3.10.255,1,0}},
//disconnect script
{2,{2,70, 0-
0:96.3.10.255,2,0}}
//reconnect script
}

Page 8 of 47
1 execute long-unsigned -/-/A

Disconnect control IC70-0 0-0:96.3.10.255 Access Rights T18


(Client 16/102/1)
1 logical_name octet-string[6] 000060030AFF -/-/G
2 output_state boolean -/-/G
3 control_state enum -/-/G
4 control_mode enum 2 -/-/GS

1 remote_disconnect integer -/-/A


2 remote_connect integer -/-/A

Limiter IC71-0 0-0:17.0.0.255 Access Rights T19


(Client 16/102/1)
1 logical_name octet-string[6] 0100110000FF -/-/G
2 monitored_value value_definition {3, 1- -/-/GS
0:90.7.0.255, 2} or
{3,1-
0:1.24.0.255, 2}
3 threshold_active threshold -/-/G
4 threshold_normal threshold -/-/GS
5 treshold_emergency threshold -/-/GS
6 min_over_threshold_duration double_long_unsigne 180 -/-/GS
d
7 min_under_threshold_duration double_long_unsigne 180 -/-/GS
d
8 emergency_profile emergency_profile_ty -/-/GS
pe

Page 9 of 47
9 emergency_profile_group_id_list array -/-/GS
10 emergency_profile_active boolean -/-/GS
11 actions action_set {...0- -/-/G
0:10.0.106.255…}

Average Instantaneous Import Power (+A) IC3-0 1-0:1.24.1.255 Access Rights T20
(Client 16/102/1)
1 logical_name octet-string[6] 0100011801FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,27} -/-/G

1 reset -/-/A

Instantaneous current IC3-0 1-0:90.7.0.255 Access Rights T21


(sum over all phases) (Client 16/102/1)
1 logical_name octet-string[6] 01005A0700FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,33} -/-/G

Errors and Alarms 3

Error Register IC1-0 0-0:97.97.0.255 Access Rights T22


(Client 16/102/1)

3
Error bit mask and alarm bit mask as per dsmr 2.31

Page 10 of 47
1 logical_name octet-string[6] 0000616100FF -/-/G
2 value double-long- -/-/GS
unsigned

Alarm Register IC1-0 0-0:97.98.0.255 Access Rights T23


(Client 16/102/1)
1 logical_name octet-string[6] 0000616200FF -/-/G
2 value double-long- -/-/GS
unsigned

Alarm Filter IC1-0 0-0:97.98.10.255 Access Rights T24


(Client 16/102/1)
1 logical_name octet-string[6] 000061620AFF -/-/G
2 value double-long- -/-/GS
unsigned

Event logs4

Event Object - Standard Event Log IC1-0 0-0:96.11.0.255 Access Rights T25
(Client 16/102/1)
1 logical_name octet-string[6] 0000600B00FF -/-/G
2 value enum -/-/G

Standard Event Log IC7-1 0-0:99.98.0.255 Access Rights T26


(Client 16/102/1)

4
List of events as per dsmr 2.31

Page 11 of 47
1 logical_name octet-string[6] 0000636200FF -/-/G
2 buffer array -/-/G
3 capture_objects array {8,0- -/-/G
0:1.0.0.255,2,0}
{0-
0:96.11.0.255,2,0}
4 capture_period double-long-unsigned 0 -/-/G
5 sort_method enum 1 -/-/G
6 sort_object capture_object_definiti none -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥100 -/-/G

1 reset integer -/-/A

Event Object - Fraud Detection Log IC1-0 0-0:96.11.1.255 Access Rights T27
(Client 16/102/1)
1 logical_name octet-string[6] 0000600B01FF -/-/G
2 value enum -/-/G

Fraud Detection Log IC7-1 0-0:99.98.1.255 Access Rights T28


(Client 16/102/1)
1 logical_name octet-string[6] 0000636201FF -/-/G
2 buffer array -/-/G
3 capture_objects array {{8,0- -/-/G
0:1.0.0.255,2,0},{1,0-
0.96.11.1.255,2,0}}
4 capture_period double-long-unsigned 0 -/-/G
5 sort_method enum 1 -/-/G

Page 12 of 47
6 sort_object capture_object_definiti none -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥30 -/-/G

1 reset integer -/-/A

Event Object - Disconnector Control log IC1-0 Access Rights T29


0-0:96.11.2.255 (Client 16/102/1)
1 logical_name octet-string[6] 0000600B02FF -/-/G
2 value enum -/-/G

Disconnector Control Log IC7-1 0-0:99.98.2.255 Access Rights T30


(Client 16/102/1)
1 logical_name octet-string[6] 0000636203FF -/-/G
2 buffer array -/-/G
3 capture_objects array { -/-/G(S)
{8, 0-0:1.0.0, 2, 0}
{1, 0-
0:96.11.2.255, 2, 0}

}
4 capture_period double-long-unsigned 0 -/-/G
5 sort_method enum 1 -/-/G
6 sort_object capture_object_definiti none -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥10 -/-/G

Page 13 of 47
1 reset integer -/-/A

Power Failure Event Log IC7-1 1-0:99.97.0.255 Access Rights T31


(Client 16/102/1)
1 logical_name octet-string[6] 0100636100FF -/-/G
2 buffer array -/-/G
3 capture_objects array[2] { -/-/G
{8,0-0:1.0.0,2,0};
{1,0-
0:96.7.19.255,2,0}
}
4 capture_period double-long-unsigned 0 -/-/G
5 sort_method enum 1 -/-/G
6 sort_object capture_object_definiti none -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥10 -/-/G

1 reset integer -/-/A

Event Object - Power Quality Log IC1-0 0-0:96.11.4.255 Access Rights T32
(Client 16/102/1)
1 logical_name octet-string[6] 0000600B04FF -/-/G
2 value enum -/-/GS

Power Quality Log IC7-1 0-0:99.98.4.255 Access Rights T33


(Client 16/102/1)
1 logical_name octet-string[6] 0000636204FF -/-/G

Page 14 of 47
2 buffer array -/-/G
3 capture_objects array { -/-/G(S)
{8,0-
0:1.0.0.255,2,0};
{1,0-
0:96.11.5.255,2,0}
}
4 capture_period double-long-unsigned 0 -/-/G
5 sort_method enum 1 -/-/G
6 sort_object capture_object_definiti none -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥100 -/-/G

1 reset -/-/A

Firmware – upgrade and versioning

Image transfer IC18-0 0-0:44.0.0.255 Access Rights T34


(Client 16/102/1)
1 logical_name octet-string[6] 00002C0000FF -/-/G
2 image_block_size double-long- -/-/G
unsigned
3 image_transferred_block_status bit-string -/-/G
4 image_first not_transferred_block_number double-long- -/-/G
unsigned
5 image_transfer_enabled boolean -/-/GS
6 image_transfer status enum -/-/G
7 image_to_activate_info array -/-/G

Page 15 of 47
1 image_transfer_initiate structure -/-/A
2 image_block_transfer structure -/-/A
3 image_verify integer -/-/A
4 image_activate integer -/-/A

Image transfer activation scheduler IC22-0 0-0:15.0.2.255 Access Rights T35


(Client 16/102/1)
1 logical_name octet-string[6] 00000F0002FF -/-/G
2 executed_script script {0- -/-/G
0:10.0.107.255,1}
3 type enum 1 -/-/G
4 execution_time array -/-/GS

Predefined Scripts - Image activation IC9-0 0-0:10.0.107.255 Access Rights T36


(Client 16/102/1)
1 logical_name octet-string[6] 00000A006BFF -/-/G
2 scripts script -- -/-/-

1 execute long-unsigned 1 -/-/A

Active firmware version IC1-0 1-0:0.2.0.255 Access Rights T37


(Client 16/102/1)
1 logical_name octet-string[6] 0100000200FF -/-/G
2 value octet- -/-/G
string[1…n]

Page 16 of 47
Active firmware version signature IC1-0 1-0:0.2.8.255 Access Rights T38
(Client 16/102/1)
1 logical_name octet-string[6] 0100000208FF -/-/G
2 value octet- -/-/G
string[1…n]

Energy registration - totals

Active energy import (+A) IC3-0 1-0:1.8.0.255 Access Rights T40


(Client 16/102/1)
1 logical_name octet-string[6] 0100010800FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,30} -/-/G

Active energy export (−A) IC3-0 1-0:2.8.0.255 Access Rights T41


(Client 16/102/1)
1 logical_name octet-string[6] 0100020800FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,30} -/-/G

Active energy (|+A|+|-A|) IC3-0 1-0:15.8.0.255 Access Rights T42


Combined total (Client 16/102/1)
1 logical_name octet-string[6] 01000F0800FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,30} -/-/G

Page 17 of 47
Reactive energy import (+R) IC3-0 1-0:3.8.0.255 Access Rights T43
(QI+QII) (Client 16/102/1)
1 logical_name octet-string[6] 0100030800FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,32} -/-/G

Reactive energy export (-R) IC3-0 1-0:4.8.0.255 Access Rights T44


(QIII+QIV) (Client 16/102/1)
1 logical_name octet-string[6] 0100040800FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,32} -/-/G

Energy registration – rates

Active energy import (+A) rate 1 IC3-0 1-0:1.8.1.255 Access Rights T54
(Client 16/102/1)
1 logical_name octet-string[6] 0100010801FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,30} -/-/G

Active energy import (+A) rate 2 IC3-0 1-0:1.8.2.255 Access Rights T55
(Client 16/102/1)
1 logical_name octet-string[6] 0100010802FF -/-/G

Page 18 of 47
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,30} -/-/G

Active energy import (+A) rate 3 IC3-0 1-0:1.8.3.255 Access Rights T56
(Client 16/102/1)
1 logical_name octet-string[6] 0100010803FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,30} -/-/G

Active energy import (+A) rate 4 IC3-0 1-0:1.8.4.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100010804FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,30} -/-/G

Active energy export (−A) rate 1 IC3-0 1-0:2.8.1.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100020801FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,30} -/-/G

Active energy export (−A) rate 2 IC3-0 1-0:2.8.2.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100020802FF -/-/G
2 value double-long-unsigned -/-/G

Page 19 of 47
3 scaler_unit scal_unit_type {0,30} -/-/G

Active energy export (−A) rate 3 IC3-0 1-0:2.8.3.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100020803FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,30} -/-/G

Active energy export (−A) rate 4 IC3-0 1-0:2.8.4.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100020804FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,30} -/-/G

Reactive energy (+R) rate 1 IC3-0 1-0:3.8.1.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100030801FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,32} -/-/G

Reactive energy (+R) rate 2 IC3-0 1-0:3.8.2.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100030802FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,32} -/-/G

Page 20 of 47
Reactive energy (+R) rate 3 IC3-0 1-0:3.8.3.255 Access Rights
(Client 16/102/1)
1 logical_name octet-string[6] 0100030803FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,32} -/-/G

Reactive energy (+R) rate 4 IC3-0 1-0:3.8.4.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100030804FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,32} -/-/G

Reactive energy (-R) rate 1 IC3-0 1-0:4.8.1.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100040801FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,32} -/-/G

Reactive energy (-R) rate 2 IC3-0 1-0:4.8.2.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100040802FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,32} -/-/G

Reactive energy (-R) rate 3 IC3-0 1-0:4.8.3.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100040803FF -/-/G

Page 21 of 47
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,32} -/-/G

Reactive energy (-R) rate 4 IC3-0 1-0:4.8.4.255 Access Rights T69


(Client 16/102/1)
1 logical_name octet-string[6] 0100040804FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,32} -/-/G

Demand registration

Demand Register 1 - Active energy import (+A) IC5-0 1-0:1.4.0.255 Access Rights T94
(Client 16/102/1)
1 logical_name octet-string[6] 0100010400FF -/-/G
2 current_average_value double-long- -/-/G
unsigned
3 last_average_value double-long- -/-/G
unsigned
4 scaler_unit scal_unit_type {0,27} -/-/G
5 status unsigned 0 -/-/G
6 capture_time octet-string -/-/G
7 start_time_current octet-string -/-/G
8 period double-long- 900 -/-/GS
unsigned
9 number_of_periods long-unsigned 1 -/-/GS

Page 22 of 47
Demand Register 2 - Active energy export (−A) IC5-0 1-0:2.4.0.255 Access Rights T95
(Client 16/102/1)
1 logical_name octet-string[6] 0100020400FF -/-/G
2 current_average_value double-long- -/-/G
unsigned
3 last_average_value double-long- -/-/G
unsigned
4 scaler_unit scal_unit_type {0,27} -/-/G
5 status unsigned 0 -/-/G
6 capture_time octet-string -/-/G
7 start_time_current octet-string -/-/G
8 period double-long- 900 -/-/GS
unsigned
9 number_of_periods long-unsigned 1 -/-/GS

Demand Register 3 - Reactive energy import (+R) IC5-0 1-0:3.4.0.255 Access Rights T96
(Client 16/102/1)
1 logical_name octet-string[6] 0100030400FF -/-/G
2 current_average_value double-long- -/-/G
unsigned
3 last_average_value double-long- -/-/G
unsigned
4 scaler_unit scal_unit_type {0,29} -/-/G
5 status unsigned 0 -/-/G
6 capture_time octet-string -/-/G
7 start_time_current octet-string -/-/G
8 period double-long- 900 -/-/GS
unsigned
9 number_of_periods long-unsigned 1 -/-/GS

Page 23 of 47
Demand Register 4 - Reactive energy export (-R) IC5-0 1-0:4.4.0.255 Access Rights T97
(Client 16/102/1)
1 logical_name octet-string[6] 0100040400FF -/-/G
2 current_average_value double-long- -/-/G
unsigned
3 last_average_value double-long- -/-/G
unsigned
4 scaler_unit scal_unit_type {0,29} -/-/G
5 status unsigned 0 -/-/G
6 capture_time octet-string -/-/G
7 start_time_current octet-string -/-/G
8 period double-long- 900 -/-/GS
unsigned
9 number_of_periods long-unsigned 1 -/-/GS

Maximum Demand Register 1 - Active energy IC4-0 1-0:1.6.0.255 Access Rights T106
import (+A) (Client 16/102/1)
1 logical_name octet-string[6] 0100010600FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 2 - Active energy import (+A) - IC4-0 1-0:1.6.1.255 Access Rights
rate 1 (Client 16/102/1)
1 logical_name octet-string[6] 0100010601FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G

Page 24 of 47
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 3 - Active energy import (+A) - IC4-0 1-0:1.6.2.255 Access Rights
rate 2 (Client 16/102/1)
1 logical_name octet-string[6] 0100010602FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 4 - Active energy import (+A) - IC4-0 1-0:1.6.3.255 Access Rights
rate 3 (Client 16/102/1)
1 logical_name octet-string[6] 0100010603FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 5 - Active energy import (+A) - IC4-0 1-0:1.6.4.255 Access Rights
rate 4 (Client 16/102/1)
1 logical_name octet-string[6] 0100010604FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Page 25 of 47
Maximum Demand Register 6 - Active energy export (−A) IC4-0 1-0:2.6.0.255 Access Rights
(Client 16/102/1)
1 logical_name octet-string[6] 0100020600FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 7 - Active energy export (−A) - IC4-0 1-0:2.6.1.255 Access Rights
rate 1 (Client 16/102/1)
1 logical_name octet-string[6] 0100020601FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 8 - Active energy export (−A) - IC4-0 1-0:2.6.2.255 Access Rights
rate 2 (Client 16/102/1)
1 logical_name octet-string[6] 0100020602FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 9 - Active energy export (−A) - IC4-0 1-0:2.6.3.255 Access Rights
rate 3 (Client 16/102/1)
1 logical_name octet-string[6] 0100020603FF -/-/G
2 value double-long-unsigned -/-/G

Page 26 of 47
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 10 - Active energy export (−A) - IC4-0 1-0:2.6.4.255 Access Rights
rate 4 (Client 16/102/1)
1 logical_name octet-string[6] 0100020604FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,27} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 11 - Reactive energy import (+R) IC4-0 1-0:3.6.0.255 Access Rights
(Client 16/102/1)
1 logical_name octet-string[6] 0100030600FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 12 - Reactive energy import (+R) - IC4-0 1-0:3.6.1.255 Access Rights
rate 1 (Client 16/102/1)
1 logical_name octet-string[6] 0100030601FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Page 27 of 47
Maximum Demand Register 13 - Reactive energy import (+R) - IC4-0 1-0:3.6.2.255 Access Rights
rate 2 (Client 16/102/1)
1 logical_name octet-string[6] 0100030602FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 14 - Reactive energy import (+R) - IC4-0 1-0:3.6.3.255 Access Rights
rate 3 (Client 16/102/1)
1 logical_name octet-string[6] 0100030603FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 15 - Reactive energy import (+R) - IC4-0 1-0:3.6.4.255 Access Rights
rate 4 (Client 16/102/1)
1 logical_name octet-string[6] 0100030604FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 16 - Reactive energy export (-R) IC4-0 1-0:4.6.0.255 Access Rights
(Client 16/102/1)
1 logical_name octet-string[6] 0100040600FF -/-/G
2 value double-long-unsigned -/-/G

Page 28 of 47
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 17 - Reactive energy export (-R) - IC4-0 1-0:4.6.1.255 Access Rights
rate 1 (Client 16/102/1)
1 logical_name octet-string[6] 0100040601FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 18 - Reactive energy export (-R) - IC4-0 1-0:4.6.2.255 Access Rights
rate 2 (Client 16/102/1)
1 logical_name octet-string[6] 0100040602FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Maximum Demand Register 19 - Reactive energy export (-R) - IC4-0 1-0:4.6.3.255 Access Rights
rate 3 (Client 16/102/1)
1 logical_name octet-string[6] 0100040603FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Page 29 of 47
Maximum Demand Register 20 - Reactive energy IC4-0 1-0:4.6.4.255 Access Rights T124
export (-R) - rate 4 (Client 16/102/1)
1 logical_name octet-string[6] 0100040604FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {1,29} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Profiles

Profile status - Load profile with period 1 IC1-0 0-0:96.10.1.255 Access Rights T135
(Client 16/102/1)
1 logical_name octet-string[6] 0000600A01FF -/-/G
2 status unsigned -/-/G

Load profile with period 1 IC7-1 1-0:99.1.0.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100630100FF -/-/G
2 buffer array -/-/G
3 capture_objects array { -/-/GS
{8,0-0:1.0.0.255 ,2};
{1, 0-0:96.10.1.255, 2};
{3, 1-0:1.6.0.255, 2}}
4 capture_period double-long-unsigned 9005 -/-/GS
5 sort_method enum 1 -/-/G

5
Min period 15 min, max 60 min

Page 30 of 47
6 sort_object capture_object_definiti {8,0-0:1.0.0.255,2,0} -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥960 -/-/G

1 reset -/-/A

Profile status - Load profile with period 2 IC1-0 0-0:96.10.2.255 Access Rights
(Client 16/102/1)
1 logical_name octet-string[6] 0000600A02FF -/-/G
2 status unsigned -/-/G

Load profile with period 2 IC7-1 1-0:99.2.0.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100630200FF -/-/G
2 buffer array -/-/G
3 capture_objects array { -/-/GS
8,0-0:1.0.0.255 ,2;
1, 0-0:96.10.1.255, 2;
3, 1-0:1.8.0.255, 2;
3, 1-0:2.8.0.255, 2
}
4 capture_period double-long-unsigned 86400 -/-/GS
5 sort_method enum 1 -/-/G
6 sort_object capture_object_definiti {8,0-0:1.0.0.255,2,0} -/-/G
on
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥10 -/-/G

Page 31 of 47
1 reset -/-/A

Power quality

Number of power failures in any phase; total IC1-0 0-0:96.7.21.255 Access Rights T139
number of power failures (Client 16/102/1)
1 logical_name octet-string[6] 0000600715FF -/-/G
2 value long-unsigned -/-/G

Number of long power failures in any phase IC1-0 0-0:96.7.9.255 Access Rights T140
(Client 16/102/1)
1 logical_name octet-string[6] 0000600709FF -/-/G
2 value long-unsigned -/-/G

Time threshold for long power failure IC3-0 0-0:96.7.20.255 Access Rights T141
(Client 16/102/1)
1 logical_name octet-string[6] 0000600714FF -/-/G
2 value long-unsigned 180 -/S/GS
3 scaler_unit scal_unit_type {0,7} -/-/G

Duration of last long power failure in any phase IC3-0 0-0:96.7.19.255 Access Rights T142
(Client 16/102/1)
1 logical_name octet-string[6] 0000600713FF -/-/G
2 value long-unsigned -/-/GS
3 scaler_unit scal_unit_type {0,7} -/-/G

Page 32 of 47
Threshold for voltage sag IC3-0 1-0:12.31.0.255 Access Rights T143
(Client 16/102/1)
1 logical_name octet-string[6] 01000C1F00FF -/-/G
2 value long-unsigned 207 -/S/GS
3 scaler_unit scal_unit_type {0,35} -/-/G

Time threshold for voltage sag IC3-0 1-0:12.43.0.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 01000C2B00FF -/-/G
2 value long-unsigned 30 -/S/GS
3 scaler_unit scal_unit_type {0,7} -/-/G

Number of voltage sags in phase L1 IC1-0 1-0:32.32.0.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100202000FF -/-/G
2 value long-unsigned -/-/G

Number of voltage sags in phase L2 IC1-0 1-0:52.32.0.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100342000FF -/-/G
2 value long-unsigned -/-/G

Number of voltage sags in phase L3 IC1-0 1-0:72.32.0.255 Access Rights T147


(Client 16/102/1)
1 logical_name octet-string[6] 0100482000FF -/-/G
2 value long-unsigned -/-/G

Page 33 of 47
Threshold for voltage swell IC3-0 1-0:12.35.0.255 Access Rights T154
(Client 16/102/1)
1 logical_name octet-string[6] 01000C2300FF -/-/G
2 value long-unsigned 253 -/S/GS
3 scaler_unit scal_unit_type {0,35} -/-/G

Time threshold for voltage swell IC3-0 1-0:12.44.0.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 01000C2C00FF -/-/G
2 value long-unsigned 30 -/S/GS
3 scaler_unit scal_unit_type {0,7} -/-/G

Number of voltage swells in phase L1 IC1-0 1-0:32.36.0.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100202400FF -/-/G
2 value long-unsigned -/-/G

Number of voltage swells in phase L2 IC1-0 1-0:52.36.0.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100342400FF -/-/G
2 value long-unsigned -/-/G

Number of voltage swells in phase L3 IC1-0 1-0:72.36.0.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0100482400FF -/-/G
2 value long-unsigned -/-/G

Page 34 of 47
Instantaneous voltage L1 IC3-0 1-0:32.7.0.255 Access Rights T168
(Client 16/102/1)
1 logical_name octet-string[6] 0100200700FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,35} -/-/G

Instantaneous current L1 IC3-0 1-0:31.7.0.255 Access Rights T170


(Client 16/102/1)
1 logical_name octet-string[6] 01001F0700FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,33} -/-/G

Instantaneous voltage L2 IC3-0 1-0:52.7.0.255 Access Rights T172


(Client 16/102/1)
1 logical_name octet-string[6] 0100340700FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,35} -/-/G

Instantaneous current L2 IC3-0 1-0:51.7.0.255 Access Rights T174


(Client 16/102/1)
1 logical_name octet-string[6] 0100330700FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,33} -/-/G

Instantaneous voltage L3 IC3-0 1-0:72.7.0.255 Access Rights T176


(Client 16/102/1)
1 logical_name octet-string[6] 0100480700FF -/-/G

Page 35 of 47
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,35} -/-/G

Instantaneous current L3 IC3-0 1-0:71.7.0.255 Access Rights T178


(Client 16/102/1)
1 logical_name octet-string[6] 0100470700FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,33} -/-/G

Instantaneous net frequency; any phase IC3-0 1-0:14.7.0.255 Access Rights T181
(Client 16/102/1)
1 logical_name octet-string[6] 01000E0700FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,44} -/-/G

Instantaneous active power (|+A|+|-A|) IC3-0 1-0:15.7.0.255 Access Rights T182


(Client 16/102/1)
1 logical_name octet-string[6] 01000F0700FF -/-/G
2 value double long- -/-/G
unsigned
3 scaler_unit scal_unit_type {1,27} -/-/G

Instantaneous Power factor (+A/+VA) IC3-0 1-0:13.7.0.255 Access Rights T191


(Client 16/102/1)
1 logical_name octet-string[6] 01000D0700FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {-3,255} -/-/G

Page 36 of 47
Last Average Power factor (+A/+VA) IC4-0 1-0:13.5.0.255 Access Rights T192
(Client 16/102/1)
1 logical_name octet-string[6] 01000D0500FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {-3,255} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Minimum Power factor (+A/+VA)6 IC4-0 1-0:13.3.0.255 Access Rights T193


(Client 16/102/1)
1 logical_name octet-string[6] 01000D0300FF -/-/G
2 value long-unsigned -/-/G
3 scaler_unit scal_unit_type {-3,255} -/-/G
4 status unsigned -/-/G
5 capture_time octet-string -/-/G

Multi Utility – Wired M-Bus single slave

M-Bus master port setup 1 IC74-0 0-0:24.6.0.255 Access Rights T194


(Client 16/102/1)
1 logical_name octet-string[6] 0000180600FF -/-/G
2 comm_speed enum 3 -/-/G

6
Minimum power factor over billing reset period

Page 37 of 47
M-Bus client channel 1 IC72-1 0-1:24.1.0.255 Access Rights T196
(Client 16/102/1)
1 logical_name octet-string[6] 0001180100FF -/-/G
2 mbus_port_reference octet-string[6] {0-0:24.6.0.255} -/-/GS

3 capture_definition array { -/-/GS


{DIF_1,VIF_1},{DIF_2,VIF_
2},
{DIF_3,VIF_3},{DIF_4,VIF_
4}
}
4 capture_period double-long- -/S/GS
unsigned
5 primary_address unsigned -/-/G
6 identification_number double-long- -/-/G
unsigned
7 manufacturer_id long-unsigned -/-/G
8 version unsigned -/-/G
9 device_type unsigned -/-/G
10 access_number unsigned -/-/G
11 status unsigned -/-/G
12 alarm unsigned 0 -/-/GS

1 slave_install unsigned -/-/A


2 slave_deinstall unsigned -/-/A
7 set_encryption_key octet-string -/-/A
8 transfer_key octet-string -/-/A

M-Bus Value channel 1, instance 1 - {DIF_1,VIF_1} IC4-0 0-1:24.2.1.255 Access Rights T200
(Client 16/102/1)

Page 38 of 47
1 logical_name octet-string[6] 0001180201FF -/-/G
2 value double-long- -/-/G
unsigned
3 scaler_unit scal_unit_type {0,255} -/-/G
4 status long-unsigned -/-/G
5 capture_time octet-string -/-/G

1 reset -/-/A

M-Bus Value channel 1, instance 2 - {DIF_2,VIF_2} IC4-0 0-1:24.2.2.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0001180202FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,255} -/-/G
4 status long-unsigned -/-/G
5 capture_time octet-string -/-/G

1 reset -/-/A

M-Bus Value channel 1, instance 3 - {DIF_3,VIF_3} IC4-0 0-1:24.2.3.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 0001180203FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,255} -/-/G
4 status long-unsigned -/-/G
5 capture_time octet-string -/-/G

1 reset -/-/A

Page 39 of 47
M-Bus Value channel 1, instance 4 - {DIF_4,VIF_4} IC4-0 0-1:24.2.4.255 Access Rights
(Client 16/102/1)
1 logical_name octet-string[6] 0001180204FF -/-/G
2 value double-long-unsigned -/-/G
3 scaler_unit scal_unit_type {0,255} -/-/G
4 status long-unsigned -/-/G
5 capture_time octet-string -/-/G

1 reset -/-/A

Profile status - M-Bus Master Load profile 1 IC1-0 0-1:96.10.3.255 Access Rights T224
(Client 16/102/1)
1 logical_name octet-string[6] 0001600A03FF -/-/G
2 status unsigned -/-/G

M-Bus Master Load profile for channel 1 IC7-1 0-1:24.3.0.255 Access Rights T228
(Client 16/102/1)
1 logical_name octet-string[6] 0001180300FF -/-/G
2 buffer array -/-/G
3 capture_objects array { -/-/GS
{8,0-
0:1.0.0.255,2,0},
{1, 0-
0:96.10.20.255,2,0},
{4, 0-
b:24.2.e.255,2,0}
}
4 capture_period double-long-unsigned 3600 -/-/GS
5 sort_method enum 1 -/-/G

Page 40 of 47
6 sort_object capture_object_definiti {8,0- -/-/G
on 0:1.0.0.255,2,0}
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥240 -/-/G

1 reset -/-/A

M-Bus Master Disconnect control object 1 IC70-0 0-1:24.4.0.255 Access Rights T232
(Client 16/102/1)
1 logical_name octet-string[6] 0001180400FF -/-/G
2 output_state boolean -/-/G
3 control_state enum -/-/G
4 control_mode enum -/S/GS

1 remote_disconnect integer -/-/A


2 remote_connect integer -/-/A

Event Objects - M-Bus Master Control logs 1 IC1-0 0-1:96.11.4.255 Access Rights T236
(Client 16/102/1)
1 logical_name octet-string[6] 0001600B04FF -/-/G
2 value enum -/-/G

M-Bus Master Control log object 1 IC7-1 Access Rights T240


0-1:24.5.0.255 (Client 16/102/1)
1 logical_name octet-string[6] 0001180500FF -/-/G
2 buffer array -/-/G
3 capture_objects array {8,0-
0:1.0.0.255,2,0} -/-/GS

Page 41 of 47
{1, 0-x:96.11.4.255,
2, 0}
4 capture_period double-long-unsigned 0 -/-/GS
5 sort_method enum 1 -/-/G
6 sort_object capture_object_definiti
on none -/-/G
7 entries_in_use double-long-unsigned -/-/G
8 profile_entries double-long-unsigned ≥10 -/-/G

1 reset -/-/A

Event Object - M-Bus Event Log IC1-0 0-0:96.11.3.255 Access Rights T244
(Client 16/102/1)
1 logical_name octet-string[6] 0000600B03FF -/-/G
2 value enum -/-/G

M-Bus Event Log IC7-1 0-0:99.98.3.255 Access Rights T245


(Client 16/102/1)
1 logical_name octet-string[6] 0000636203FF -/-/G
2 buffer array -/-/G
3 capture_objects array {8,0- -/-/GS
0:1.0.0.255,2,0}
{1,0-
0:96.11.3.255,2,0}
4 capture_period double-long-unsigned 0 -/-/GS
5 sort_method enum 1 -/-/G
6 sort_object capture_object_definiti none -/-/G
on
7 entries_in_use double-long-unsigned -/-/G

Page 42 of 47
8 profile_entries double-long-unsigned ≥10 -/-/G

1 reset -/-/A

M-Bus Device ID 1 channel 1 IC1-0 Access Rights T216


(Client 16/102/1)
1 logical_name octet-string[6] 0001600100FF
2 value octet-string

M-Bus Device ID 2 channel 1 IC1-0 Access Rights T220


(Client 16/102/1)
1 logical_name octet-string[6]
2 value octet-string

Communication – setup and statistics

IEC HDLC setup - HDLC Optical port IC23-1 0-0:22.0.0.255 Access Rights T247
(Client 16/102/1)
1 logical_name octet-string[6] 0000160000FF -/-/G
2 comm_speed enum 5 -/S/GS
3 window_size_transmit unsigned 1 -/S/GS
4 window_size_receive unsigned 1 -/S/GS
5 max_info_field_lenght_transmit unsigned 248 -/S/GS
6 max_info_field_lenght_receive unsigned 62 -/S/GS
7 inter_octet_time_out long-unsigned 150 -/S/GS
8 inactivity_time_out long-unsigned 120 -/S/GS
9 device_address long-unsigned 0 -/-/GS

Page 43 of 47
S-FSK Phy&MAC setup IC50-1 0-0:26.0.0.255 Access Rights T248
(Client 16/102/1)
1 logical_name octet-string[6] 00001A0000FF -/-/G
2 initiator_electrical_phase enum 0 -/-/G
3 delta_electrical_phase enum 1 -/-/G
4 max_receiving_gain unsigned -/S/GS
5 max_transmitting_gain unsigned -/S/GS
6 search_initiator_gain unsigned -/S/GS
7 frequencies frequencies_typ {63300,74000} -/S/GS
e
8 mac_address long-unsigned 0xFFE -/-/G
9 mac_group_addresses array[5] {0,0,0,0,0} -/-/GS
10 repeater enum 1 -/-/GS
11 repeater_status boolean -/-/G
12 min_delta_credit unsigned 0 -/S/GS
13 initiator_mac_address long-unsigned 0x0000 -/-/G
14 synchronization_locked boolean -/-/G
15 transmission_speed enum 3 -/S/GS

S-FSK Active Initiator IC51-0 0-0:26.1.0.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 00001A0100FF -/-/G
2 active_initiator initiator_descriptor -/-/G

1 reset_NEW_not_synchronised long-unsigned -/A/A

S-FSK MAC synchronisation timeouts IC52-0 0-0:26.2.0.255 Access Rights

Page 44 of 47
(Client 16/102/1)
1 logical_name octet-string[6] 00001A0200FF -/-/G
2 search_initiator_timeout long-unsigned -/S/GS
3 synchronization_confirmation_ timeout long-unsigned -/S/GS
4 timeout_not_addressed long-unsigned -/S/GS
5 timeout_frame_not_OK long-unsigned -/S/GS

S-FSK MAC counters IC53-0 0-0:26.3.0.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 00001A0300FF -/-/G
2 synchronization_register array[3] -/-/G
3 desynchronization_listing structure[5] -/-/G
4 broadcast_frames_counter array[3] -/-/G
5 repetitions_counter double-long-unsigned -/S/GS
6 transmissions_counter double-long-unsigned -/S/GS
7 CRC_OK_frames_counter double-long-unsigned -/-/G
8 CRC_NOK_frames_counter double-long-unsigned -/-/G

S-FSK IEC 61334-4-32 LLC Setup IC55-0 0-0:26.5.0.255 Access Rights


(Client 16/102/1)
1 logical_name octet-string[6] 00001A0500FF -/-/G
2 max_frame_length unsigned 134 -/S/GS
3 reply_status_list array[1] {{0,7}} -/-/G

Profile status

Flag Description

Page 45 of 47
Bit 7 Power down: This bit is set to indicate that an all-phase power
PDN failure occurred.
Bit 6 not used

Bit 5 Clock adjusted: The bit is set when the clock has been adjusted
CAD more than the synchronisation limit. At the same time the DNV flag
is set because the capture period deviates from its nominal lengths
and may not be used for billing.
Bit 4 not used

Bit 3 Daylight saving: Indicates whether or not the daylight saving time
DST is currently active. The bit is set if the daylight saving time is active
Bit 2 (summer) and cleared
Data not valid: in that
Indicates winter.
the current entry may not be used for
DNV billing e.g. due to time shift or if no values have been recorded
during the capture period.
Bit 1 Clock invalid: The power reserve of the calendar clock has been
CIV exhausted. The time is declared as invalid. At the same time the
Bit 0 Critical error: A serious error such as a hardware failure or a
ERR checksum error has occurred. At the same time, the DNV bit is set.

Alarm descriptor

Alarm Descriptor
Bit Alarm
0 PLC state new
1 Clock invalid
2 reserved
3 reserved

Page 46 of 47
4 reserved
5 reserved
6 reserved
7 Extended Alarm status

Alarm Descriptor is related to CIASE Alarm Delivery where bit 0 is PLC_NEW, 1 to 6 are the same as in the Alarm Register bits 0 to 5 and bit 7
indicates Extended Alarm status that any of bit 6 to bit 31 of Alarm Register is set.

Page 47 of 47