Width of column b= 200 mm LOAD- 400 KN Depth of column D= 400 mm SIZE:- Effective length of column Leff= 2700 mm WIDTH:- 200 Ratio Leff / b <12 short column 13.5 >12 DEPTH:- 400 Reduction factor Cr=1.25-(Leff./48/b) Cr= 0.969 BAR:- 6 14 Charecteristic strength of reinfo. fy= 415 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 80000 sqmm Ultimate load on column 1.5xP Pu= 600 KN Net load on col Pu(net)= Pu/Cr Pu(net)= 619 KN Pu(Net) = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= -76 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 320 sqmm PROVIDE 6 BAR 14 Asc(pro) = 923 sqmm AREA PROVIDED OK
DESIGN OF LONG COLUMN COL. N0:- C2
Load on a column P= 500 KN SUMMERY
Width of column b= 200 mm LOAD- 500 KN Depth of column D= 500 mm SIZE:- Effective length of column Leff= 2700 mm WIDTH:- 200 Ratio Leff / b <12 short column 13.5 >12 DEPTH:- 500 Reduction factor Cr=1.25-(Leff./48/b) Cr= 0.969 BAR:- 8 14 Charecteristic strength of reinfo. fy= 415 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 100000 sqmm Ultimate load on column 1.5xP Pu= 750 KN Net load on col Pu(net)= Pu/Cr Pu(net)= 774 KN Pu(Net) = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= -94 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 400 sqmm PROVIDE 8 BAR 14 Asc(pro) = 1231 sqmm AREA PROVIDED OK
42 DESIGN OF LONG COLUMN COL. N0:- C3
Load on a column P= 575 KN SUMMERY
Width of column b= 200 mm LOAD- 575 KN Depth of column D= 500 mm SIZE:- Effective length of column Leff= 2700 mm WIDTH:- 200 Ratio Leff / b <12 short column 13.5 >12 DEPTH:- 500 Reduction factor Cr=1.25-(Leff./48/b) Cr= 0.969 BAR:- 10 14 Charecteristic strength of reinfo. fy= 415 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 100000 sqmm Ultimate load on column 1.5xP Pu= 862.5 KN Net load on col Pu(net)= Pu/Cr Pu(net)= 890 KN Pu(Net) = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 324 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 400 sqmm PROVIDE 10 BAR 14 Asc(pro) = 1539 sqmm AREA PROVIDED OK
DESIGN OF LONG COLUMN COL. N0:- C4
Load on a column P= 680 KN SUMMERY
Width of column b= 200 mm LOAD- 680 KN Depth of column D= 600 mm SIZE:- Effective length of column Leff= 2700 mm WIDTH:- 200 Ratio Leff / b <12 short column 13.5 >12 DEPTH:- 600 Reduction factor Cr=1.25-(Leff./48/b) Cr= 0.969 BAR:- 12 14 Charecteristic strength of reinfo. fy= 415 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 120000 sqmm Ultimate load on column 1.5xP Pu= 1020 KN Net load on col Pu(net)= Pu/Cr Pu(net)= 1053 KN Pu(Net) = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 334 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 480 sqmm PROVIDE 12 BAR 14 Asc(pro) = 1846 sqmm AREA PROVIDED OK 43 DESIGN OF LONG COLUMN COL. N0:- C5
Load on a column P= 800 KN SUMMERY
Width of column b= 200 mm LOAD- 800 KN Depth of column D= 700 mm SIZE:- Effective length of column Leff= 2700 mm WIDTH:- 200 Ratio Leff / b <12 short column 13.5 >12 DEPTH:- 700 Reduction factor Cr=1.25-(Leff./48/b) Cr= 0.969 BAR:- 12 16 Charecteristic strength of reinfo. fy= 415 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 140000 sqmm Ultimate load on column 1.5xP Pu= 1200 KN Net load on col Pu(net)= Pu/Cr Pu(net)= 1238 KN Pu(Net) = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 424 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 560 sqmm PROVIDE 12 BAR 16 Asc(pro) = 2412 sqmm AREA PROVIDED OK
DESIGN OF LONG COLUMN COL. N0:- C6
Load on a column P= 800 KN SUMMERY
Width of column b= 200 mm LOAD- 800 KN Depth of column D= 700 mm SIZE:- Effective length of column Leff= 2700 mm WIDTH:- 200 Ratio Leff / b <12 short column 13.5 >12 DEPTH:- 700 Reduction factor Cr=1.25-(Leff./48/b) Cr= 0.969 BAR:- 14 16 Charecteristic strength of reinfo. fy= 415 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 140000 sqmm Ultimate load on column 1.5xP Pu= 1200 KN Net load on col Pu(net)= Pu/Cr Pu(net)= 1238 KN Pu(Net) = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 424 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 560 sqmm PROVIDE 14 BAR 16 Asc(pro) = 2813 sqmm AREA PROVIDED OK 44