Result EDT-135

________________________________________________________________________________

WAVETEK WANDEL GOLTERMANN E1 AND DATA TESTER EDT-135 14:59 29 Mac 2011
________________________________________________________________________________

Printout of test results for test number 1


Start time 12:43 17 Mac 2011
Stop time 12:42 18 Mac 2011
Total test time (seconds) 86400
Line rate 2047993
Total code errors received 0
Total mean Code Error Ratio 0.000E 0

Bit rate 2047992


Total bits received 2.458E 9
Total errors received 0
Total mean Bit Error Ratio 0.000E 0

Seconds of no signal 0
Seconds of AIS 0
Seconds of pattern sync loss 0
Seconds of Pattern Inverted 0
Seconds of all zeros 0
Seconds of slip 0

Available time 86400 100.00000%


Unavailable time 0 0.00000%

Error free seconds 86400 100.00000%


Errored seconds PASS 0 0.00000%

Severely errored seconds PASS 0 0.00000%


Non-severely errored seconds 86400 100.00000%
________________________________________________________________________________

WAVETEK WANDEL GOLTERMANN E1 AND DATA TESTER EDT-135 14:59 29 Mac 2011
________________________________________________________________________________

Printout of menu settings

*Setup Menu 1*
Mode RX/TX
Interface G.703
Line code HDB3
Framing OFF
Termination 75/120 Ohm
Tx Clk source FROM RX
kbps 2048
*Setup Menu 2*
BERT pattern 2^9-1
Bits/Block OFF
Rx logic NORM
Tx logic NORM
*Setup Menu 3*
Autoprint OFF
G.821 ITU-T
Alarms ALL ON
Resolution HRS/MINS