Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
SECTION 2
400
Maximum Speed Curve
Minimum Speed Curve
300
TDH(Feet)
200
100
0
0 1 2 3 4 5 6 7 8
GPM
Performance Curves
H [ft]
Pump curve
at 10,700 rpm
Pump curve
Min. head at no flow
at 3,000 rpm
CU 321 CU 301
WATER TANK
2 gallon tank min. for SQE
4 gallon tank min. for CU 321
PRESSURE SENSOR
2-1
PERFORMANCE CURVES SQE
100
0
0 1 2 3 4 5 6 7 8
GPM
OUTLET SIZE: 1" NPT NOMINAL DIA. 3"
200
TDH(Feet)
100
0
0 1 2 3 4 5 6 7 8
GPM
OUTLET SIZE: 1" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-2
PERFORMANCE CURVES SQE
300
TDH(Feet)
200
100
0
0 1 2 3 4 5 6 7 8
GPM
OUTLET SIZE: 1" NPT NOMINAL DIA. 3"
300
250
TDH(Feet)
200
150
100
50
0
0 1 2 3 4 5 6 7 8
GPM
OUTLET SIZE: 1" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-3
PERFORMANCE CURVES SQE
400
350
TDH(Feet)
300
250
200
150
100
50
0
0 1 2 3 4 5 6 7 8
GPM
OUTLET SIZE: 1" NPT NOMINAL DIA. 3"
400
TDH(Feet)
300
200
100
0
0 1 2 3 4 5 6 7 8
GPM
OUTLET SIZE: 1" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-4
PERFORMANCE CURVES SQE
500
TDH(Feet)
400
300
200
100
0
0 1 2 3 4 5 6 7 8
GPM
OUTLET SIZE: 1" NPT NOMINAL DIA. 3"
500
TDH(Feet)
400
300
200
100
0
0 1 2 3 4 5 6 7 8
GPM
OUTLET SIZE: 1" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-5
PERFORMANCE CURVES SQE
600
500
TDH(Feet)
400
300
200
100
0
0 1 2 3 4 5 6 7 8
GPM
100
0
0 2 4 6 8 10 12 14 16
GPM
OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-6
PERFORMANCE CURVES SQE
200
TDH (Feet)
100
0
0 2 4 6 8 10 12 14 16
GPM
200
TDH(Feet)
100
0
0 2 4 6 8 10 12 14 16
GPM
OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-7
PERFORMANCE CURVES SQE
300
TDH(Feet)
200
100
0
0 2 4 6 8 10 12 14 16
GPM
OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3"
400
TDH(Feet)
300
200
100
0
0 2 4 6 8 10 12 14 16
GPM
OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-8
PERFORMANCE CURVES SQE
400
TDH(Feet)
300
200
100
0
0 2 4 6 8 10 12 14 16
GPM
OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3"
100
0
0 2 4 6 8 10 12 14 16 18 20
GPM
2-9
PERFORMANCE CURVES SQE
100
0
0 2 4 6 8 10 12 14 16 18 20
GPM
OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3"
200
TDH(Feet)
100
0
0 2 4 6 8 10 12 14 16 18 20
GPM
OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-10
PERFORMANCE CURVES SQE
300
TDH(Feet)
200
100
0
0 2 4 6 8 10 12 14 16 18 20
GPM
OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3"
300
TDH(Feet)
200
100
0
0 2 4 6 8 10 12 14 16 18 20
GPM
2-11
PERFORMANCE CURVES SQE
400
TDH(Feet)
300
200
100
0
0 2 4 6 8 10 12 14 16 18 20
GPM
OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3"
400
TDH(Feet)
300
200
100
0
0 2 4 6 8 10 12 14 16 18 20
GPM
OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-12
PERFORMANCE CURVES SQE
50
0
0 5 10 15 20 25 30 35
GPM
OUTLET SIZE: 1 1/2" NPT NOMINAL DIA. 3"
100
TDH(Feet)
50
0
0 5 10 15 20 25 30 35
GPM
OUTLET SIZE: 1 1/2" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-13
PERFORMANCE CURVES SQE
150
TDH(Feet)
100
50
0
0 5 10 15 20 25 30 35
GPM
OUTLET SIZE: 1 1/2" NPT NOMINAL DIA. 3"
200
TDH(Feet)
150
100
50
0
0 5 10 15 20 25 30 35
GPM
OUTLET SIZE: 1 1/2" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-14
PERFORMANCE CURVES SQE
200
TDH(Feet)
150
100
50
0
0 5 10 15 20 25 30 35
GPM
300
250
TDH(Feet)
200
150
100
50
0
0 5 10 15 20 25 30 35
GPM
2-15
PERFORMANCE CURVES SQE
50
0
0 5 10 15 20 25 30 35 40 45
GPM
OUTLET SIZE: 1 1/2" NPT NOMINAL DIA. 3"
100
TDH(Feet)
50
0
0 5 10 15 20 25 30 35 40 45
GPM
OUTLET SIZE: 1 1/2" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-16
PERFORMANCE CURVES SQE
200
TDH(Feet)
150
100
50
0
0 5 10 15 20 25 30 35 40 45
GPM
OUTLET SIZE: 1 1/2" NPT NOMINAL DIA. 3"
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
2-17
SYSTEM SIZING GUIDE SQE
Step 1
Calculate minimum head requirements at no flow conditions:
Hmax (required) = dynamic head + system pressure (in feet) + above grade elevation + friction loss.
Step 2
Select pump from chart as follows:
> Choose model family based on the desired flow rate. i.e. 15SQE for a flow rate of 15gpm
> Select the first model with a value in Column 2 greater than the Hmax calculated in Step 1
> For example: the choice for a 22gpm model with an Hmax of 140' would be the 22SQE-160.
Double check your selection in the performance curves found in the previous pages of this book.
Col. 1 Col. 2
H [ft]
S yste m S iz ing M a trix
Pump curve
S hutoff He a d at 10,700 rpm
He a d @ Ra te d
(0 GP M ) @
P um p Type M ode l B GP M @ 10700
3000 RP M
RP M M a x . S pe e d
M in. S pe e d
TDH(Fe e t) TDH(Fe e t)
Max. head at rated flow
Pump curve
5S QE -90 11 86
Min. head at no flow
at 3,000 rpm
5S QE -140 17 131
5S QE -180 22 177
5S QE -230 28 222
15S QE -70 10 75
15S QE -110 14 123
15S QE -150 19 164
15S QE -180 24 205
15S QE -220 29 246
15S QE -250 33 287
15S QE -290 38 328
22S QE -40 5 36
22S QE -80 9 77
22S QE -120 14 117
22S QE -160 18 159
22S QE -190 23 200
22S QE -220 27 240
30S QE -40 5 33
30S QE -90 11 82
30S QE -130 16 126
2-18
PERFORMANCE CURVES CU321 VARIABLE SPEED - 3 HP
60 Hz
700
55 Hz
600
500 50 Hz
45 Hz
400
40 Hz
300
35 Hz
200
30 Hz
100
0
0 2 4 6 8 10 12 14 16 18 Q(US GPM)
2-19
PERFORMANCE CURVES CU321 VARIABLE SPEED - 5 HP
60 Hz
1000
55 Hz
800 50 Hz
45 Hz
600
40 Hz
400 35 Hz
30 Hz
200
0
0 2 4 6 8 10 12 14 16 18 Q(US GPM)
2-20
PERFORMANCE CURVES CU321 VARIABLE SPEED - 3 HP
60 Hz
400
55 Hz
50 Hz
300
45 Hz
40 Hz
200
35 Hz
30 Hz
100
0
0 5 10 15 20 25 30 Q(US GPM)
2-21
PERFORMANCE CURVES CU321 VARIABLE SPEED - 5 HP
800 60 Hz
700
55 Hz
600
50 Hz
500
45 Hz
400
40 Hz
300
35 Hz
200 30 Hz
100
0
0 5 10 15 20 25 30 Q(US GPM)
2-22
PERFORMANCE CURVES CU321 VARIABLE SPEED - 3 HP
60 Hz
240
55 Hz
200
50 Hz
160
45 Hz
120
40 Hz
35 Hz
80
30 Hz
40
0
0 5 10 15 20 25 30 35 40 45 50 Q(US GPM)
2-23
PERFORMANCE CURVES CU321 VARIABLE SPEED - 5 HP
440
60 Hz
400
360 55 Hz
320
50 Hz
280
45 Hz
240
200
40 Hz
160
35 Hz
120
30 Hz
80
40
0
0 5 10 15 20 25 30 35 40 45 50 Q(US GPM)
2-24
PERFORMANCE CURVES CU321 VARIABLE SPEED - 3 HP
60 Hz
160
140
55 Hz
120
50 Hz
100
45 Hz
80
40 Hz
60
35 Hz
30 Hz
40
20
0
0 10 20 30 40 50 60 70 80 Q(US GPM)
2-25
PERFORMANCE CURVES CU321 VARIABLE SPEED - 5 HP
60 Hz
240
55 Hz
200
50 Hz
160
45 Hz
120 40 Hz
35 Hz
80
30 Hz
40
0
0 10 20 30 40 50 60 70 80 Q(US GPM)
2-26
SYSTEM SIZING GUIDE SmartFlo™ - CU321
Step 1
Calculate maximum head requirements at rated flow conditions:
Hmax = dynamic head + system psi (in feet) + friction loss + above grade elevation
Step 2
Select pump from chart as follows:
> Select a model in which the calculated value of Hmax is below the value in columns 2
> For example: the choice for a 40gpm model with an Hmax of 150 would be the 40S30-9
Col. 1 Col. 2
S yste m S iz ing M a trix
S hutoff He a d
He a d @ Ra te d
(0 GP M ) @
P um p Type GP M @ 3600 RP M
1500 RP M
M a x . S pe e d
M in. S pe e d
2-27
2-28
SmartFlo™ ACCESSORIES
SmartFlo™ Accessories
2-29
SmartFlo™ ACCESSORIES
2-30
SmartFlo™ ACCESSORIES
2-31
2-32