Sei sulla pagina 1di 1

3-2 Polyethylene Pin Type Insulators – Tie-Top 3-2

Electrical, Mechanical & Physical Data


Polyethylene Pin Type Insulators
Telephone: (603) 673-2040 • Fax: (603) 673-1497 • Email: overhead@hendrix-wc.com • Website: http://www.hendrix-wc.com

Characteristic HPI-15 HPI-15F HPI-25 HPI-25-02 HPI-25J HPI-25J-02 HPI-35** HPI-35-02** HPI-35J** HPI-35J-02**
Neck Style C F F F J J F F J J
Typical Application, kV 15 15 25 25 25 25 35 35 35 35
ANSI Class 55-3 55-4 55-5 55-5 56-1 56-1 55-6* 55-6* 55-6 55-6
Leakage Distance, inches 13.6 12.5 14.6 14.5 14.0 13.8 21.1 21.0 20.8 20.7
Dry Arcing Distance, inches 7 6.7 8.3 8.3 8.1 8.1 10.2 10.2 10.0 10.0
Pin Hole Diameter, inches* 1 1 1 13/8 1 13/8 1 13/8 1 13/8
Hendrix Wire & Cable Inc., • 53 Old Wilton Road • Milford, NH 03055-3119

Minimum Pin Length, inches 6 6 6 6 6 6 7*** 7*** 7*** 7***


60Hz Dry Flashover, kV 84 80 87 87 95 95 106 106 91 91
60Hz Wet Flashover, kV 43 46 51 51 57 57 70 70 63 63
Positive Impulse Flashover, kV 123 122 144 144 143 143 168 168 147 147
Negative Impulse Flashover, kV 207 202 179 179 190 190 225 225 219 219
A member of The Marmon Group of companies

Low Frequency Puncture, kV 210 215 225 220 220 215 235 230 230 225
RIV @1MHz 10 kV to grd, PV <10 <10 <10 <10 <10 <10 <10 <10 <10 <10
15 kV to grd, PV - - <10 <10 <10 <10 <10 <10 <10 <10
22 kV to grd,.PV - - - - - - <10 <10 <10 <10
Cantilever Strength, lbs. 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000
Dimensions, inches A 51/4 51/4 51/2 51/2 57/8 57/8 71/8 71/8 71/2 71/2
B 51/2 51/2 71/2 71/2 71/2 71/2 71/2 71/2 71/2 71/2
C 37/8 37/8 4 4 4 4 51/2 51/2 51/2 51/2

OVERHEAD PRODUCTS
D 21/4 27/8 27/8 27/8 31/2 31/2 27/8 27/8 31/2 31/2
E 3/ 1 1 1
4 1 1 1 1 1 1

F 3/ 3/ 7/ 7/ 7/ 7/ 7/ 7/ 7/ 7/
4 4 8 8 8 8 8 8 8 8

Max. Conductor, inches 1.38 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75
Weight, lbs. 1.1 1.2 2.1 2.1 2.3 2.3 2.7 2.7 2.9 2.9
Maximum continuous 120 120 120 120 120 120 120 120 120 120
conductor operating temp., C°

When ordering Vise-Top insulators, specify the suffix “P” for covered conductors and bare copper conductors
or “M” for bare aluminum conductors.
Different pin hole diameters and thread configurations to meet international standards are available upon request.
*Meets all requirements of 55-6 except J neck.
**Review design performance data before using on bare wire systems.
***ANSI C29.5 requires a minimum pin height of 7 1/2.
****Cantilever strength refers to side clamp loading.