SP SOFTWARE (IOG) UPGRADE

1. Check which SP systems that are installed on the IOG. Make sure that the same
system and version is installed in both nodes.
Command: LASYP:SPG=0,VNODE=A;
Command: LASYP:SPG=0,VNODE=B;
Printout: SP SYSTEM LIST
--------------------------------------------------------------------------------
-------------
2. Make sure that both nodes are working normal.
Command: IMMCT:SPG=0;
Command: IMCSP;
Printout: NODE CONFIGURATION STATUS
Command: END;
--------------------------------------------------------------------------------
-------------
3. Insert optical disc (OD) into the optical drive in node A.
--------------------------------------------------------------------------------
-------------
4. Mount the OD.
Command: INMCT:SPG=0;
Command: INVOL:NODE=A,IO=OD-1;
Printout: VOLUME LOADED
Command: END;
--------------------------------------------------------------------------------
-------------
5. Start SP function change.
Command: FCSPI:SPG=0;
--------------------------------------------------------------------------------
-------------
6. Specify nodes to be updated.
Command: FCSLS:LNODE=A&B,RNODE=A&B,RSNODE=A&B;
--------------------------------------------------------------------------------
-------------
7. Load SP software from OD to HD.
Command: FCSSL:IONODE=A,IO=OD-1;
Printout: SP SOFTWARE LOAD
--------------------------------------------------------------------------------
-------------
8. Load SP system description from OD to HD.
Command: FCSDL:IONODE=A,IO=OD-1;
Printout: SP SYSTEM DESCRIPTION LOAD
--------------------------------------------------------------------------------
-------------
9. Install and switch in the new SP system.
Command: FCSSI:FCTYPE=1;
Printout: SP FUNCTION CHANGE
--------------------------------------------------------------------------------
-------------
10. End the SP function change.
Command: FCSPE;
Printout: SP FUNCTION CHANGE ENDED
--------------------------------------------------------------------------------
-------------
11. Make sure that the new SP system is active in both nodes.
Command: LASYP:SPG=0,VNODE=A;
Command: LASYP:SPG=0,VNODE=B;
Printout: SP SYSTEM LIST
--------------------------------------------------------------------------------
-------------
12. Make sure that both nodes are working normal.
Command: IMMCT:SPG=0;
Command: IMCSP;
Printout: NODE CONFIGURATION STATUS
Command: END;
--------------------------------------------------------------------------------
-------------
13. Unmount the and remove the OD.
Command: INMCT:SPG=0;
Command: INVOE:IO=OD-1, NODE=A;
Command: END;
Printout: VOLUME UNLOADED
--------------------------------------------------------------------------------
-------------