HEATING COMPONENTS

COMBINATION SINGLE STAGE DUAL GAS VALVE, REDUNDANT


• REPLACES MANY POPULAR BRANDS
• SLOW OPENING
• SINGLE STAGE
• LP KIT INCLUDED
• 24 VOLT OPERATOR
• QUICK CONNECT TERMINALS
• INLET AND OUTLET PRESSURE TAPS
• OFF-PILOT-ON PROGRAMMED LIGHTING SEQUENCE FOR STANDING PILOT
APPLICATION
• PILOT COMPRESSION FITTING FOR 1/4 INCH O.D. TUBING
P465

FOR USE WITH GAS TYPE CAPACITY PRESS.


SIZE (in.) P/N
NAT. L.P. 1000 BTU’s IN. W.C.
1/2 x 3/4 YES YES* 130 3.5 P681-1501*

*LP kit is included.

REPLACES: Single and Dual valve standing pilot controls with rated capacity on natural gas at 130,000 BTU/HR.
HONEYWELL: V800 & VR800
WHITE-RODGERS: 36C03-300, 36C03-330, 36C03-400 & 36C03-433
ITT GENERAL: B57RA68, B57RF68, B57RH161, B59R02 & B59R06
ROBERTSHAW: 700-400, 700-402 & 700-406
STEVECO: 215-508

332
HEATING COMPONENTS
COMBINATION GAS CONTROLS
• MANUAL MAIN AND PILOT • MANUAL MAIN AND PILOT
GAS SHUTOFF GAS SHUTOFF
• PILOT GAS OUTLET WITH • PILOT GAS OUTLET WITH
ADJUSTMENT ADJUSTMENT
• OUTLET GAS PRESSURE • OUTLET GAS PRESSURE
TAP TAP
• 24 VOLT OPERATOR
• 24 VOLT OPERATOR
• AUTO PILOT SHUTOFF
AND PRESSURE • AUTO PILOT SHUTOFF
REGULATION AS NOTED AND PRESSURE
REGULATION AS NOTED
• CAPACITY: 240,000 BTU’s
P467
• PRESSURE SET AT: 3.5 @ • PRESSURE SET AT:
P468
125M 3.5 C& 150M EF33CB181 11
@ 125M EF53CK248
SIZE PRESS USE WITH 100%
P/N
(in.) REG. NAT. L.P. SHUTOFF USE WITH 100%
SIZE PRESS CAPACITY
1/2 x 3/4 YES YES - NO EF53CK185 SHUT- P/N
(in.) REG. NAT. L.P. 1000 BTU’s
1/2 x 3/4 YES YES YES YES EF680006* OFF
1/2 x 1/2 YES YES - NO EF53CK198† 1/2 x 1/2 YES YES - 225 NO EF33CB181
1/2 x 1/2 NO - YES YES EF53CK208 3/4 x 3/4 YES - YES 486 YES EF53CK248
1/2 x 1/2 YES YES - YES EF53CK205†

*Kit contains EF53CK188 VALVE, Blankoff plate for converting to LP gas


applications and 3/4’ to 1/2’ reducer bushing.
†Slow Opening

• MANUAL MAIN AND PILOT • HEAT MOTOR GIVES TIME DELAY


GAS SHUTOFF • SIZE 1/2′ x 3/4′, HAS PRESSURE REGULATOR, USE WITH
• NATURAL GAS NATURAL GAS, PRESSURE SET AT. 3.5 @125M
• PILOT OUTLET WITH • CAPACITY: 164,000 BTU’s
ADJUSTMENT • NON 100% SHUTOFF
• OUTLET GAS PRESSURE • INCLUDES 3/4′ x 1/2′ REDUCER BUSHING
TAP
P/N: EF53CK198
• 24 VOLT OPERATOR
• PRESSURE REGULATOR
P469

COMBINATION DUAL VALVE GAS CONTROLS


• DUAL MAIN ELECTRIC VALVES - REDUNDANT
• MANUAL MAIN GAS SHUTOFF
• OUTLET GAS PRESSURE TAP (EF32CW183)
• INLET & OUTLET GAS PRESSURE TAPS
(EF32CW190)
• PRESSURE REGULATOR
• PILOT GAS ADJUSTMENT.
• I.I.D. SYSTEM APPLICABLE
P470 • 24 VOLT OPERATOR
• PICK AND HOLD OPERATION.

SIZE USE w/ CAPACITY PRESS.


P/N
(in.) (TYPE GAS) 1000 BTU’s SET AT
1/2 x 3/4 NAT. 125 3.5 @ 110M EF32CWI83*
1/2 x 3/4 NAT. 140 3.5 EF32CWI90

333
HEATING COMPONENTS
COMBINATION DUAL VALVE GAS CONTROLS
• SINGLE STAGE - • SINGLE STAGE -
REDUNDANT REDUNDANT
• SLOW OPENING • 24 VOLT OPERATOR
• 24 VOLT OPERATOR • PRESSURE REGULATOR
• PRESSURE REGULATOR • USE WITH G67 ELECTRONIC
IGNITION
P471 • PILOT GAS ADJUSTMENT
P474

SIZE USE WITH CAPACITY PRESS. SIZE USE WITH CAPACITY PRESS.
IN. W.C. P/N P/N
(in.) NAT. L.P. 1000 BTU’s (in.) NAT. L. P. 1000 BTU’s IN. W.C.
1/2 x 3/4 YES - 130 3.5 EF32CB212 1/2 x 3/4 YES - 175 3.5 EF33CZ213

• DUAL MAIN ELECTRIC SIMILAR MODELS TO RCD P/N EF33CZ206 WITH SLIGHT
VALVES - REDUNDANT CHANGES:
• I.I.D. SYSTEM APPLICABLE • SIZE 1/2′ x 1/2′
• 24 VOLT OPERATOR • CAPACITY 179,000 BTU’s
• OUTLET GAS PRESSURE P/N: EF33CZ209
TAP
• SOLENOID COILS COVERED
• SOLENOID COILS EASILY
REPLACED • IGNITER MOUNTS NEXT TO COILS

P472 • PRESSURE REGULATOR P/N: EF33CZ210

• NATURAL GAS
• SIZE 1/2′ x 3/4′
• PRESSURE SET AT: 3.5 @
125M
• CAPACITY 200,000 BTU’s
P/N: EF33CZ206

• DUAL MAIN ELECTRIC


• DUAL MAIN ELECTRIC
VALVES - REDUNDANT
VALVES - REDUNDANT
• MANUAL MAIN GAS
• MANUAL MAIN GAS
SHUTOFF
SHUTOFF
• 24 VOLT OPERATOR
• I.I.D. SYSTEM APPLICABLE
• ADJUSTABLE PILOT GAS
• PILOT GAS ADJUSTMENT
FLOW
• PRESSURE REGULATOR
• OUTLET GAS PRESSURE
TAP • OUTLET GAS PRESSURE
P473 TAP
• PRESSURE REGULATOR P475
• NATURAL GAS
• NATURAL GAS
• 24 VOLT OPERATOR
• I.I.D. SYSTEM APPLICABLE

SIZE CAPACITY PRESS.


SYSTEM P/N
SIZE CAPACITY PRESS. (in.) 1000 BTU’s SET AT
P/N 1/2 x 1/2 200 3.5 @ 125M I.I.D. EF32CB195
(in.) 1000 BTU’s SET AT
1/2 x 3/4 250 3.5 EF680007 3/4 x 3/4 335 3.5 @ 110M I.I.D. EF34CW245

NOTE: Package includes EF32CB210 valve and 3/4 to 1/2 *Special pilot porting for zip tube ignition.
reducer bushing. .

334
HEATING COMPONENTS
COMBINATION TWO STAGE GAS CONTROLS
• DUAL MAIN ELECTRIC
• PRE-SELECTED FIRST VALVES - REDUNDANT
STAGE FIRING RATE • PRE-SELECTED FIRST
• ADJUSTABLE HIGH FIRE STAGE FIRING RATE
RATE • 24 VOLT OPERATOR
• 24 VOLT OPERATOR • MANUAL MAIN GAS
• MANUAL MAIN GAS SHUTOFF
SHUTOFF • PILOT GAS ADJUSTMENT
• PILOT GAS ADJUSTMENT • OUTLET GAS PRESSURE
• OUTLET GAS PRESSURE TAP
TAP • PRESSURE REGULATOR
P478
P476 • PRESSURE REGULATOR • I.I.D. SYSTEM APPLICABLE
PRESS.
USE PRESS. 100% SIZE USE WITH CAPACITY
CAPACITY IN. W.C. P/N
SIZE (in.) 1000 BTU’s
WITH 1000 IN. W.C. SHUT- P/N NAT. L.P. LO Hi
(in.)
NAT. L.P. BTU’s LO HI OFF 3/4 x 3/4 YES - 250 1.3 3.5 EF33CB265
1/2 x 1/2 - YES 225 2.2 11.0 NO EF33CW186 1/2 x 1/2 - YES 324 2.2 11.0 EF33CB209
3/4 x 3/4 YES - 335 1.3 3.5 NO EF680016 3/4 x 3/4 YES - 335 1.5 3.4 EF33CB265
3/4 x 3/4 YES - 335 .9 3.5 YES EF34CW245 3/4 x 3/4 - YES 335 2.2 11.0 EF33CB268

• INTERNAL PRESSURE • DUAL MAIN ELECTRIC


SWITCH VALVES - REDUNDANT
• DUAL MAIN ELECTRIC • PRE-SELECTED FIRST
VALVES - REDUNDANT STAGE FIRING RATE
• PRE-SELECTED FIRST • 24 VOLT OPERATOR
• STAGE FIRING RATE • MANUAL MAIN GAS
• 24 VOLT OPERATOR SHUTOFF
• MANUAL MAIN GAS • OUTLET GAS PRESSURE
SHUTOFF TAP
• PILOT GAS ADJUSTMENT • PRESSURE REGULATOR
• OUTLET GAS PRESSURE • I.I.D. SYSTEM APPLICABLE
TAP
P479
P477 • PRESSURE REGULATOR
• I.I.D. SYSTEM APPLICABLE PRESS.
SIZE USE WITH CAPACITY
IN. W.C. P/N
(in.) 1000 BTU’s
PRESS. NAT. L.P. LO Hi
SIZE USE WITH CAPACITY 1/2 x 3/4 YES - 110 3.5 1.6 EF33CZ255
IN. W.C. P/N
(in.) 1000 BTU’s
NAT. L.P. LO HI 1/2 x 3/4 - YES 195 10.5 4.8 EF33CZ256
3/4 x 3/4 - YES 335 3.4 11.0 EF33CW289

P/N P681-VR8345M P/N P660-VR83A


Universal Electronic Ignition Gas Valve Continuous Pilot Dual Automatic Valve Combi-
• CONTROL INCLUDES MANUAL nation Gas Controls
VALVE, TWO AUTOMATIC OPERA- • CONTROLS INCLUDE SAFETY SHUTOFF,
TORS, PRESSURE REGULATORS, MANUAL VALVE, TWO AUTOMATIC OPERA-
PILOT ADJUSTMENT, PILOT PLUG TORS, PRESSURE REGULATOR AND PILOT
AND IGNITION ADAPTER. ADJUSTMENT.
• HIGHEST CAPACITY (415,000 BTU • REPLACES OVER 95 PERCENT OF THE
MAX. REG., NG) OF ANY ELEC- STANDING PILOT GAS VALVES; MAXIMUM
TRONIC IGNITION VALVE IN THE CAPACITY RATING IS 150% OF THE COM-
P471 INDUSTRY. PETITIVE VALVES.
• REPLACES VIRTUALLY ANY IP, HIS, • MEETS 1979 ANSI STANDARDS FOR
OR DSI GAS CONTROL. REDUNDANCY IN GAS VALVE OPERATION.
• FOR USE WITH NATURAL OR MANU- PART NUMBER HONEYWELL PART NUMBER
FACTURED GAS OR LP GAS. P660-VR83A3500 VR8300A3500
• HONEYWELL P/N: VR8345M4302. P660-VR83A3518 VR8300A3518
P660-VR83A4508 VR8300A4508
P660-VR83A4516 VR8300A4516

335
HEATING COMPONENTS
BURNER IGNITION SYSTEMS
P/N P660-Y8610U
Universal Retrofit Intermittent Pilot Gas Burner Ignition System
• COMBINES THE MOST UNIVERSAL IGNITION CONTROLS (S8610 IP MODULE & VR8304M
GAS VALVE) INTO THE MOST CAPABLE RETROFIT KIT AVAILABLE.
• SINGLE-ROD OR DUAL-ROD IGNITION AND SENSING SIMPLIFIES INSTALLATION WITH
ONLY ONE LEAD TO WIRE.
• SOPHISTICATED LOCKOUT TIMING ELIMINATES NUISANCE LOCKOUTS.
• HONEYWELL P/N: Y8610U3003.
P/N P660-Y8610F
P4318
Retrofit Intermittent Pilot Gas Burner Ignition System
• Y8610F KITS ARE FOR USE WITH NATURAL GAS ONLY: CONTINUE TRIAL FOR IGNITION
UNTIL THE PILOT LIGHTS OR THE SYSTEM IS SHUT DOWN MANUALLY.
• COMPLETE KIT FOR CONVERTING STANDING PILOT TO INTERMITTENT PILOT.
• NOT 100% SHUTOFF ON PILOT FLAME LOSS; IDEAL FOR MOST NATURAL GAS
SYSTEMS.
• HONEYWELL P/N: Y8610F5003.

SMARTVALVE SYSTEM
P/N P682-SV9501M SmartValve System
• COMBINES GAS FLOW AND ELECTRONIC INTERMITTENT PILOT SEQUENCING
FUNCTIONS INTO A SINGLE UNIT.
• SUITABLE FOR A WIDE RANGE OF GAS-FIRED APPLIANCES INCLUDING RESIDEN-
TIAL FURNACES, ROOFTOP FURNACES, RESIDENTIAL BOILERS, UNIT HEATERS,
INFRARED HEATERS, AND SPACE HEATERS.
• HONEYWELL P/N: SV9501M2528.

P4319

336
HEATING COMPONENTS
SINGLE FUNCTION GAS CONTROLS
• MAIN LINE GAS VALVE
• FAST ACTING SOLENOID SERVICE

• NATURAL AND L.P. GASES • FAST ACTING SOLENOID

• HIGH CAPACITY • NATURAL AND L.P. GASES

• 1/4 IN. ELECTRICAL QUICK • HIGH CAPACITY


CONNECTS • 30″ ELECTRICAL LEADS
(EXCEPT EF11CW182)

P480
• PILOT SWITCH RECEPTACLE,
P486 EXCEPT-.
RCD P/N: EF11CW182

PILOT VALVES BTU’s PER


SIZE SIZE (in.) COIL VOLTS P/N
BTU’s COIL P/N HOUR
(in.)
PER HOUR VOLTS 1/2 x 1/2 340,000 25 EF11CW042*
1/2 x 1/2 329,000 24 EF11CW042* 1/2 x 1/2 340,000 25 EF11WH025
1/2 x 1/2 329,000 115 EF11CW044† 1/2 x 1/2 329,000 230 EF11CW032†
*Contains (2) 1/2 x 1/4, (2) 1/4 x 1/8 and (2) 1/2 x 3/8 reducer bushings. 3/4 x 3/4 500,000 25 EF11WK025
†Contains (2) 1/2 x 1/4 and (2) 1/4 x 1/8 reducer bushings. 3/4 x 3/4 500,000 115 EF11WK115
*Contains (2) 1/2 x 1/4, (2) 1/4 x 1/8 and (2) 1/2 x 3/8 reducer bushings.
†Contains (2) 1/2 x 1/4 and (2) 1/4 x 1/8 reducer bushings.

MANUAL GAS SHUTOFF VALVE


PILOT SHUTOFF VALVE
• ALUMINUM BODY
• 1/8 NPT PILOT
CONNECTION
CONNECTIONS: 1/8 NPT x 1/4
COMPRESSION COUPLING
P482 P483
FIG. A FIG. B

OVERALL P487
SIZE (in.) PILOT HEIGHT
FIG. LENGTH P/N
(NPT) CONN. (in.)
(in.)
A 1/2 x 1/2 Both Plugged 2.8 3.0 EV44CK047
TYPE BODY P/N
B 3/4 x 3/4 One Plugged 3.1 3.6 EV44CK052
Right Angle Aluminum EV43CR956

337
HEATING COMPONENTS
GAS VALVE ACCESSORIES
GAS PRESSURE REGULATOR

• REGULATOR IS 5 PSI TO
4 INCHES WC.

P488

INPUT CAPACITY
VENDOR PIPE SIZE
NATURAL GAS P/N
P/N (IN.)
(BTUH)
Maxitrol 1/2 RV52 1/2 262,000 EF680009
Maxitrol 3/4 RV53 3/4 687,750 EF680010
NOTE: Pressure set at 3 inches wc.; however, serviceman should always
check calibration at time of installation.

GAS VALVE CONVERTERS/KITS


REGULATOR AND GASKET SET HONEYWELL STEP OPENING
USED TO CONVERT ROBERT- REGULATOR FOR CONVER-
SHAW VH700 & 700 MODEL GAS SION OF RCD EF33CY254
VALVES FROM REGULATED VALVE FROM NATURAL GAS
NATURAL GAS TO REGULATED SERVICE TO
L.P. GAS
REGULATED L.P. GAS
MFG. P/N: 82446 (11.0- W.C./4.5- W.C.)
P/N: 302989-102 MFG. P/N: V5307A117
P492
P/N: 58GP305671-101

CONVERTS JOHNSON
CONTROL GAS VALVES FROM
REGULATOR SPRING CON-
NATURAL GAS TO REGULATED
VERTS W-R MODEL 36C & 36E
L.P. GAS
P489 GAS VALVE FROM NATURAL
GAS TO REGULATED L.P. GAS

MODELS WITH TOP ADJUSTED REGULATORS: MFG. P/N: 92-0659


G60 - MFG P/N: Y71GF-4 . . . . . . . . . . . . .P/N: EF39AB009 P/N: EF39ZWO23
G53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P/N: EF39AB010 RCD 646 & 647 VALVE CON-
MODELS WITH BOTTOM ADJUSTED P493 VERSIONS
REGULATORS:
G96 & G196 . . . . . . . . . . . . . . . . . . . . . . . .P/N: EF39AB011
SPRING
P/N
COLOR SIZE
RED 3.3″ x .30″
301248-102
CONVERTS NOM. 3.5” NAT. TO NOM. 11.0" L.P.
PLAIN 3.0″ x .30″
301248-101
P490 CONVERTS NOM. 11.0” LP. TO NOM. 3.5" NAT.

HONEYWELL VALVES WITH V5306, VR8200 OR VR8204 BUSHING


PRESSURE REGULATORS CAN BE CONVERTED FOR REG-
1/2″ x 3/4″ NPT FACE BUSHING
ULATED L.P. GAS SERVICE BY USING THESE KITS. COM-
PLETE REGULATOR NEED NOT BE CHANGED. • USE TO ADAPT 3/4″ NPT
PORTED GAS VALVES FOR
V5306 - MFG.P/N: 391937 . . . . . . . . . . . . . . . . . P/N: EF39AB001 USE WHERE 1/2″ NPT
VR8200, VR8402 - PIPING AND MANIFOLDS
MGF. P/N: 393691 . . . . . . . . . . . . . . . . . . . . . . . P/N: EF39ZW025 ARE PROVIDED
P/N: CA57AP202
P494

338
ORIFICES
MAIN BURNER ORIFICES

P495
P500
DRILL SIZE P/N DRILL SIZE P/N
DRILL SIZE RCD P/N DRILL SIZE P/N
3/8″ ACROSS FLATS, 11/32 x 32 NST, .31″ LONG
38 (.101) LH32DB038 43 (.089) LH32DB043
9/16″ ACROSS FLATS, 1/4 x 18 NPT, 7/8″ LONG
42 (.093) LH32DB042 53 (.059) LH32DB053 52 (.063) LH32RQBG31 35 (.110) LH32RQ110
54 (.055) LH32DB054 7/16″ ACROSS FLATS, 1/8 27 NPT, 7/8″ LONG
7/16″ ACROSS FLATS, 1/8 x 27 NPT, .50″ LONG 56 (.046) LH32JB046
53 (.059) LH32DB060 54 (0.55) LH32DB203 55 (.052) LH32JB053 43 (.089) LH32JB089
41 (.067) LH32DB096 101 (.057) LH32DB204 54 (.055) LH32JB056 41 (.096) LH32JB097
40 (.098) LH32DB098 45 (.082) LH32DB205 53 (.059) 68459C53 40 (.098) LH32JB099
44 (.086) LH32DB200 56 (.046) LH32DB206 47 (.078) LH32JB078 37 (.104) LH32JB104
55 (.052) LH32DB201 42 (.093) LH32DB207
43 (.089) LH32DB202 46 (.081) LH32DB208
9/16″ ACROSS FLATS, 1/4 x 18 NPT, 5/8″ LONG
54 (.055) LH32JB055 41 (.096) LH32JB096
53 (.059) LH32JB059 38 (.101) LH32JB101
52 (.063) LH32JB063 36 (.106) LH32JB106
42 (.093) LH32JB093 P501

DRILL SIZE P/N I DRILL SIZE P/N


9/16″ ACROSS FLATS, 1/4 x 18 NPT, 7/8″ LONG, 495 DIA.
65 (.035) LH32RF035 45 (.082) LH32RF082
56 (.046) LH32RF047 44 (.086) LH32RF086
55 (.052) LH32RF052 41 (.096) LH32RF096
P496
54 (.055) LH32RF055 38 (.101) LH32RF102
50 (.070) LH32RF070 33 (.113) LH32RF113
DRILL SIZE P/N F DRILL SIZE P/N
49 (.073) LH32RF073 32 (.116) LH32RF116
7/16″ ACROSS FLATS, 1/8 x 27 NPT, 7/8″ LONG, DIA. -
55 (0.52) LH32EB053 45 (.082) LH32EB081

PILOT ORIFICES
WHITE-RODGERS HONEYWELL GENERAL
CONTROLS

P503 PENN
P497 P498 P499 P502 ROBERTSHAW P504
BDP
ORIFICE PART TYPE
ORIFICE PART TYPE P/N
P/N SIZE MARKING GAS
SIZE MARKING GAS
GENERAL CONTROLS USED WITH 26T PILOTS
WHITE-RODGERS USED WITH “E” SERIES PILOTS
.010 .010 LP LH32DB001
.010 10U LP LH39WD010
ROBERTSHAW USED WITH 2CH PILOTS
.012 12U LP LH39WD012
.018 18U NAT LH39WD018 .010 LP10 LP LH32DB002
.020 2OU NAT LH39WD020
BDP USED WITH 732, 733, 734 and 740 PILOTS
.017 BRIGHT NAT LH39JN001 ORIFICE PART TYPE
DIM. (in.) P/N
SIZE MARKING GAS
HONEYWELL USED WITH Q308, Q314, Q345 PILOTS
PENN USED WITH “J” SERIES PILOTS
.010 BLACK LP LH32RMO15
.009 4209 LP 39/64 LH32RN109
.018 BRIGHT NAT LH32RMO16
.009 4709 LP 1-1/32 LH32RN009
.012 BBR12 LP LH32AN012
.011 4711 LP 1-9/64 LH39GB011
.014 BBR14 NAT LH32AN014
.018 7218 NAT 39/64 LH39GB019
.023 3723 NAT 39/64 LH39GB022

339
FAN, LIMIT CONTROLS
LIMIT CONTROLS
• MANUAL RESET • TEMP SETTING:
• FOR LINE OR LOW ADJ. 160-250 (HH127ZA008)
VOLTAGE CIRCUIT (HH680400)
ADJ. 150-250
• DIFFERENTIAL LIMIT 25° F (HH12ZA011)(HH680405)
• NON-ADJUSTABLE • DIFFERENTIAL: 30° F
SETTINGS
• SWITCH: SPST
• ELEMENT LENGTH: 3" P507

P505
ELEMENT LENGTH (in.) P/N
3-3/8 HH12ZA008
SWITCH TEMP. SETTING (°F) 3 HH680400
P/N
TYPE OPENS CLOSES 7-3/8 HH680405
SPST 200 175 HH12AD204 7 HH680405

FAN CONTROLS
• KNURLED SHAFTS FOR • QUICK CONNECT
ADJUSTMENT OF TERMINALS
TEMPERATURE SETTING • 24-VOLT FAN ASSIST
AND DIFFERENTIAL HEATER
• SLOTTED FOR TWO • TUBE CONSTRUCTION FOR
SCREW MOUNTING STRENGTH
• SWITCH TYPE: SPST • SLOTTED FOR 2 SCREW
P506 MOUNTING
• TEMP SETTING: FAN OFF - ADJ. 80° F-120° F
P508 • SWITCH TYPE: SPST
• FAN DIFFERENTIAL: ADJ. 20° F-50° F
• ADJUSTABLE FAN
ELEMENT LENGTH (in.) P/N SETTINGS
7 HH12AB140
3 HH12AB141 • TEMP. SETTING: FAN OFF - ADJ. 80° F - 120° F
• FAN DIFFERENTIAL: 30° F
• ELEMENT LENGTH: 1-1/4"
P/N: HH12HA070

TOTALINE® COMBINATION FAN, LIMIT CONTROLS


• MANUAL FAN SWITCH • TEMPERATURE SETTING:
FAN OFF/ON - ADJ. 90° F-135° F (P232-0001,0002)
• INDIVIDUAL FAN AND LIMIT SWITCHES
- ADJ. 90° F-130° F (P232-0003)
• HELICAL BI-METAL FOR PRECISE SETTING LIMIT OPENS - ADJ. 100° F-250° F (P232-0001,0002)
• SPST SWITCH - ADJ. 100° F-220° F (P232-0003)

• ADJUSTABLE SETTINGS ELEMENT ELEMENT


P/N P/N
LENGTH (in.) LENGTH (in.)
• DIFFERENTIAL: LIMIT- 25° F 8 P232-0001 11.5 P232-0003
5 P232-0002

P509

340
FAN, LIMIT CONTROLS

• WITH FAN ASSIST HEATER • IDEAL FOR PLENUM


TO PREVENT NUISANCE MOUNTING
FAN STARTING
• INDIVIDUAL ELEMENTS AND
• INDIVIDUAL SENSING SWITCHES
ELEMENTS
• ELEMENTS MAY BE
• BI-METAL ACTUATED REPOSITIONED
• SWITCH TYPE: SPST • PROVIDED WITH COVER
• TEMP SETTING: P511 • SWITCH TYPE: SPST
FAN OFF - • TEMP SETTING:FAN ON - 70° F-150° F
ADJ. 90° F-120° F LIMIT OPENS - 100° F-250° F
LIMIT OPENS -
SEE CHART BELOW • DIFFERENTIAL:FAN - 15° F-55° F
P510 LIMIT - 20° F
• SETTINGS ADJUSTABLE: FAN, LIMIT
• DIFFERENTIAL:
FAN - 80° F, EXCEPT HH12KA250 WHICH IS 50° F ELEMENT LENGTH (IN.) P/N
LIMIT - 30° F 9 HH12PZ008
• ELEMENT LENGTH:
7″ (EXCEPT HH12ZW125 WHICH IS 5″)
• SLOTTED FOR 2 SCREW
TEMP. SETTING SETTINGS MOUNTING
P/N
LIMIT OPENS (°F) ADJUSTABLE • RIGID TUBE
250 FAN HH12KA250 CONSTURCTION
190 FAN HH12KD020 • 24 VOLT FAN ASSIST
150-250 ADJ. FAN, LIMIT HH12KD021* HEATER
150-250 ADJ. FAN, LIMIT HH12KD022** • QUICK CONNECT
P512 ELECTRICAL TERMINALS
220 FAN HH12KD023
• SWITCH TYPE: SPST
125 FAN HH12KD024
• *TEMP SETTING: FAN OFF -
170 FAN HH12KD025 ADJ. 80° F-120° F LIMIT
125 FAN HH12ZW125 OPENS - SEE CHART BELOW
*With Shield. • DIFFERENTIAL: FAN - 35° F;
**Without Shield. LIMIT - 40° F

TEMP. SETTING SETTINGS


P/N
LIMIT OPENS (°F) ADJUSTABLE
259 5-3/4 HH680505

COMBINATION FAN, LIMIT CONTROLS


• INDIVIDUAL FAN AND LIMIT SWITCHES
• HELICAL BI-METAL FOR PRECISE SETTING
• SPST SWITCH
• ADJUSTABLE SETTINGS
• DIFFERENTIAL: LIMIT -25°
• TEMPERATURE SETTING:
FAN OFF/ON -ADJ. 90° F-135° F (HH12AT005,008)
-ADJ. 90° F-130° F (HH12AT015)
P509
LIMIT OPENS -ADJ. 100° F-250° F (HH12AT005,008)
-ADJ. 100° F-220° F (HH12AT015)
• TEMPERATURE SETTING:
FAN ON - 20 TO 90 SECONDS AFTER FAN ASSIST ELEMENT ELEMENT
P/N P/N
HEATER ENERGIZED (HH12AT016) LENGTH (in.) LENGTH (in.)
FAN OFF - ADJ. 100° F 5 HH12AT005 11.5 HH12AT015
LIMIT OPENS - ADJ. 150° F-250° F 8 HH12AT008 8 HH12AT016

341
FAN, LIMIT CONTROLS
COMBINATION FAN, LIMIT CONTROLS (cont)
P/N P232-L4064B
Fan and Limit Control
TOTALINE HONEYWELL
DESCRIPTION
• FAST RESPONSE BIMETAL ELEMENT PART NUMBER PART NUMBER
WITH LARGER SURFACE AREA P232-L4064B-11 L4064B2210 Fan & Limit 11-1/2″
ALLOWS FASTER ROTATION DURING
P232-L4064B-8 L4064B2228 Fan & Limit, 8″
TEMPERATURE CHANGE
RESPONSE. P232-L4064B-5 L4064B2236 Fan & Limit, 5″

• FASTER TEMPERATURE CHANGE


RECOGNITION FOR SAFER
OPERATION.
P509 • WIDER OPENING STEEL
SURROUNDING BIMETAL ELEMENT
ALLOWS HOT GAS PENETRATION
FOR FASTER TEMPERATURE
SENSING AND IMPROVED
TEMPERATURE TRACKING.

SWITCH - COMBINATION FAN AND LIMIT

SWITCH SWITCH
ELEMENT SWITCH OPENS SWITCH OPENS
CLOSES CLOSES
LENGTH ADJ. FAN ADJ. FAN P/N
ADJ. FAN ADJ. FAN
(in.) RANGE (°F) RANGE (°F)
RANGE (°F) RANGE (°F)
6 90-120 75 FIXED 230 FIXED 30 FIXED HH680501
7 90-120 35 FIXED 200 FIXED 30 FIXED HH680502
7 90-120 75 FIXED 240 FIXED 30 FIXED HH680504
7 90-120 50 FIXED 150-250 30 FIXED HH680506
P510

342
FAN, LIMIT CONTROLS
FAN SWITCH - INSERTION TYPE
• KNURLED SHAFTS FOR ADJUSTMENT OF TEMPERATURE SETTING AND
DIFFERENTIAL
• SLOTTED FOR TWO SCREW MOUNTING.
ELEMENT SWITCH CLOSES SWITCH OPENS
SWITCH
LENGTH ADJUSTABLE FAN ADJUSTABLE FAN P/N
TYPE
(in.) RANGE (°F) RANGE (°F)
3 80-120 25 FIXED SPST L4068E1047
3 70-140 25-45 SPST HH680201
3 80-120 65 FIXED SPST HH680203
7 70-140 25-45 SPST HH680204
7 80-110 65 FIXED SPDT HH680205
P506

FAN LIMIT SWITCH - INSERTION TYPE

ELEMENT SWITCH CLOSES SWITCH OPENS


SWITCH
LENGTH ADJUSTABLE FAN ADJUSTABLE FAN P/N
TYPE
(in.) RANGE (°F) RANGE (°F)
7 180 FIXED 10 FIXED SPDT HH680401
7 190 FIXED 30 FIXED SPDT HH680402
7 200 FIXED 30 FIXED SPDT HH680403
7 210 FIXED 30 FIXED SPDT HH680404
7 165 FIXED 30 FIXED SPDT HH11KT165
7 180 FIXED 40 FIXED SPST HH12ZB178
3 160 FIXED 30 FIXED SPST HH12ZA162
7 170 FIXED 40 FIXED SPST HH12ZA169

P505

343
IGNITION SYSTEMS
PILOT BURNERS

LH33JZ053 is a differential
expansion pilot equipped with
a 2 lead SPST switch for use
with glow coil or spark ignition.
PILOT ORIFICE
P/N
STYLE SIZE
The 2H or 2CH Pilot has SPDT 732C .017 LH33JZ053
switch action for use with 11 volt P517
glow coil systems.
P513
Differential expansion pilot
equipped with a 3 lead SPDT
PILOT STYLE GAS ORIFICE SIZE P/N
switch for use with glow coil or
2H w/COIL NAT. .021 LH680006
spark ignition.
2H w/o COIL NAT. .021 LH680004
Molex connector included.
The 734 model pilot burner is for PILOT ORIFICE
P/N
use with a 30 MV thermocouple STYLE SIZE
in standing pilot applications. 740A .017 LH680005
Snap in or threaded thermocou-
P518
ples may be used.
ORIFICE
GAS P/N
SIZE This LH31RB015 model pilot
NAT. .017 LH31JZ022 burner is used in standing pilot
applications. 2 pilot orifices are
P514
provided. One for natural gas is
installed in the burner. The
Model E28 pilot burner is for extra one is for use with L.P.
assembly with LH33WZ506 elec- gas.
trode and HH71PD001 sensor.
Spark igniter LH33WZ059 and ORIFICE
GAS P/N
SIZE
pilot orifice LH39WD020 must be P519
ordered separately. NAT. .016
MODEL NO. 2CH LH31RB015
L.P. .010
• NATURAL GAS
PILOT ORIFICE
STYLE SIZE
P/N The Q345 pilot burner includes
P515 E28 .020 LH31WZ507
pilot orifice, spark electrode
and flame ground. This burner
The following “J” style pilot burn- is for use with Honeywell S86
ers are for use with LH33CM600 spark module.
spark igniter. Converts to LP gas with
Burners come with spark elec- LH32RM015 pilot orifice.
trode and high tension lead and ORIFICE
insulating boot attached. Sensor P520 GAS P/N
SIZE
LH33CM018 and spark genera- MODEL NO. Q345 NAT. .018 LH680001
P516 tor LH33CZ007 required.
P313A

HOOD LEAD ORIFICE


P/N
POSITION* LENGTH (in.) SIZE
LH 17.0 .023 LH31CM017
Q314A pilot burner is
ST 18.0 .018 LH31CM023
a nonaerated type
ST 12.5 .023, .009 LH660003**
with .018 orifice for
LH 17.0 .023 LH660004
use with natural gas
ST 20.0 .023 LH31CM300
P524B P/N LH660001
*Angle of hood as viewed from electrode LH-Left Hand, ST-Straight.
** Includes LH31CM021 Nat. gas burner and LH32RN009 orifice for L.P. P524
conversion.

344
IGNITION SYSTEMS
PILOT BURNERS
The E25 and E27 model pilot
burners are for use with
LH31WM001 Igniter and Q314A pilot burner is a non-aer-
HH71PD001 Sensor. ated type with .018 orifice for use
LH33WM001 Igniter must be with natural gas.
used with HT01AW024 Ignition
Transformer.
Pilot orifice LH39WD020 not
furnished. P524

• NATURAL GAS

P521 • ORIFICE SIZE: .020

P524A
MODEL NUMBER P/N
E25 (LH) LH31WF038
E27 (RH) LH31WF039 P524B P/N: LH31AC013

P/N: LH31AC015

IGNITERS
This solid state igniter features
push on high tension lead con-
nector. Igniter provides continu-
ous spark until pilot flame is
established. 24 volt system.
Replaces: LH33EP030,
LH33WZ502.
IGNITER MODEL: 990 P525
P522 IGNITER MODEL:G60 P526

P/N: LH33CM600 IGNITER MODEL:G67


VOLTS FUNCTION P/N
P/N: LH33CZ003
24 NON-100% LOCKOUT LH33WZ510
24 5 MIN. 100% LOCKOUT LH33WZ512 Use these igniters with the “J” style pilot burners. Igniters are
5 MIN. 100% LOCKOUT w/20 suitable for panel mounting. The LH33CM600 may be mounted
24 LH33WZ513
SEC. PILOT GAS PREPURGE directly on Penn valves EF33CZ206 and 209. The LH33CZ003
can be mounted on Penn valve EF33CZ210 by removing mount-
ing bracket.
This igniter provides intermit- The LH33CM018 sensor and RM01680001 sensor cable are
tent pilot burner ignition. S86E required. 24 volt system.
provides continuous trial for
ignition. S86G and S86H pro- Universal Intermittent Pilot Module
vides safe lockout if pilot does • Provides ignition sequence, flame
not ignite in 90 second trial for rectification and safety shutoff for
ignition period, intermittent pilot central furnaces
and heating appliances.
System volts - 25. • For use with single rod or dual
rod/remote sense applications.
P523 • For use with natural or LP gas.
• Replaces over 300 existing IP P4316
IGNITER COMPATIBLE modules including Honeywell,
P/N
MODEL H-W VALVE Robertshaw, Penn Johnson,
S86E 844,8440 LH660010 Fenwal and others.
S86H ALL I.I.D. VALVES LH660011
S86F ALL I.I.D. VALVES LH680510 P/N: P691-S8610U

345
IGNITION SYSTEMS
IGNITERS
Solid state igniter creates the Solid state igniter for use with glow
ignition voltage required to ignite coils used on 732 and 740 pilot
pilot gas. Provides automatic burner. Igniter cycles glow coil and
relight if pilot flame is extin- regulates coil voltage to increase coil
guished while thermostat is call- life. System volts - 24.
ing for heat.
IGNITER MODEL P/N
Igniter model 5059. 870 LH33JZ050
P527
P531

• Use with “J” style pilot.


PRIMARY POWER CONNECTIONS
P/N • Panel mount.
VOLTS PRIMARY SECONDARY
• 24 volt.
25 1/4″ Q.C. 1/4″ Q.C. 5059-023
SPARK PLUG • 100% lockout, 120 sec. nominal trial for
120 6″ LEADS LH33WZ059 ignition, with 4 second pilot gas prepurge.
OR 1/4″ Q.C.
NOTE: For use with LH31WZ507 pilot burner and LH33WZ506 elec- MODEL: G770
trode. HH71PD001 used as flame sensor and pilot switch.
P/N: LH33CZ007

The SX611 Ignition Module gen- P532


erates a high-voltage spark and
provides a continuous trial for
pilot ignition. The SX611 will also
automatically try to re-establish
HOT SURFACE IGNITER
the pilot flame should it be extin-
guished while the thermostat is Designed for use with LH680-012or
calling for heat. 013 flame sensor.

IGNITER NORTON MODEL: 271


MODEL P/N P/N: LH33ZS004
P1210
SX611 LH33EP040

P534

Universal Hot Surface Ignition Module


• Provides easy field-replacement
of a wide range of hot surface
ignition modules by Honeywell,
Robertshaw and White Rodgers.
• Single rod or remote dual rod
rectification type flame sensing.
• LED signals system lockout, weak
flame signal or internal error.
• Selectable number of ignition
trials (1 or 3).
P4317
• Selectable length of trial for
ignition (4 or 7 seconds).

P/N: P691-S910U

P1209

346
IGNITION SYSTEMS

ELECTRODES GLOW COILS


This electrode is designed for This is the replacement ignition
mounting on pilot burner coil for the 2H pilot burner sup-
LH31WZ507. Spark igniter plied in the LH68006 pile pack-
LH33WZ505 and flame sensor age. Use with 48DA660025
HH71PD001 are required for resistance wire package.
complete ignition system.
PILOT STYLE: 2H
MODEL NO.: 760
NOM. VOLTS: 10
P535 P/N: LH33WZ506
P/N: LH39JZ051
P538
Designed specifically for use with
LH68005 and LH33JZ053 pilot
burners. Locating tabs and lock- This igniter coil assembly is used
ing screw provide accurate loca- with pilot burners LH68005 and
tion for required spark gap. Spike LH33JZ053 glow coil voltage
connection replaces quick con- source must be limited to maxi-
nect style. mum of 11 volts.
MODEL NO.: AM11 PILOT STYLE: 740
P536 P/N: LH680512 NOM. VOLTS: 10
P539 P/N: LH39JZ020
This sensor is required for use
with the LH33CM600 spark
igniter. It is designed for mounting
on the Penn “J” style pilot burners. This igniter is designed for use
with transformer HT01BD024.
MODEL NO.: Y75 Refer to appliance manufac-
P/N: LH33CM018 turer’s instructions for mounting.
PILOT STYLE: J
P537
NOM. VOLTS: 2.5

P543 P/N: HH79CZ036


Provided with mounting clip. 60”
leads with 5/64” thick insulation.
WHITE-RODGERS
MODEL NO: 760-679
P/N: LH33EW058
P540

FLAME SENSOR
Sensor is designed for use with LH33ZS004
Hot Surface Igniter.
MODEL NO.: CE6
P/N: 80° FURNACE USE LH680012
90° FURNACE USE LH680013

P541

347
IGNITION SYSTEMS
THERMOCOUPLES
TOTALINE THERMOCOUPLE KIT
UNIVERSAL THERMOCOUPLE
* FOR 30 MILLIVOLT CONTROLS
* ADAPTERS TO FIT MOST PILOT BURNERS P/N P671-Q340A Universal Thermocouple
* INSTALLATION INSTRUCTIONS ON • REPLACES ALMOST ANY 30 mV THERMOCOUPLE.
PACKAGE • AVERAGE OPERATING LIFE OF TEN YEARS.
With only three adapter fittings this thermocouple will
service most pilot burners old or new, while the selec- • BOTTOM LOCK DESIGN ALLOWS FOR ONE HAND
tion of lengths assures you of competitive INSTALLATION.
pricing. • UNIVERSAL ADAPTER MAKES THIS THE TWO-TO-ONE
INSTALLER-PREFERRED THERMOCOUPLE IN
LENGTH (in.) P/N
INDEPENDENT HVAC SURVEY.
24 P671-4242
30 P671-4302
HONEYWELL
36 P671-4362 PART NUMBER DESCRIPTION
PART NUMBER
48 P671-4482
P671-Q340A-18 A340A1066 Thermocouple 18″
P466 Most pilot burner applications can be serviced with this P671-Q340A-24 Q340A1074 Thermocouple 24″
thermocouple replacement kit. Thermocouple has nom-
P671-Q340A-30 Q340A1082 Thermocouple 30″
inal 30 millivolt rating and comes with instructions.
P671-Q340A-36 Q340A1090 Thermocouple 36″
P671-Q340A-48 Q340A1108 Thermocouple 48″

PILOT SAFETY SWITCHES

• SOLID STATE LOCKOUT


This auto reset, mercury filled, TIMER
SPDT pilot switch is used with
• 30 SECOND TRIAL FOR
glow coil and spark ignition sys-
IGNITION
tems.
• MAY BE RESET AFTER 30
Check unit manufacturer’s parts SEC.
list for matching pilot burners.
• 24 VOLT INPUT
MODEL NO.: 3049 MODEL NO.: 990l141
P/N: HH72CH003
P544

P547
BULB
TERM. CAPIL.
MOUNTING P/N This auto reset, SPDT pilot switch
CONN. (in.) LENGTH (in.)
STYLE
is used with a nominal 30MV ther-
1/4 Q.C. LOCKNUT 30 HH71PD001
mocouple.
1/45 Q.C. “C” RING 30 HH71PD024
Electrical connections are
enclosed. Mount upright in box or
on panel. Lighting pilot automati-
cally closes switch.
This 100% shut-off pilot switch
is for use with a nominal 30MV MODEL NO.: L61LL
thermocouple. On pilot flame P/N: HH71CC150
failure, pilot gas and power to P548
main valve are shut off until
pilot is manually re-established.
Manual reset pilot control which
MODEL NO.: L62CC
shuts off gas to pilot and main
TUBE SIZE: 1/4″ O.D. burners when pilot flame fails.
P/N: HH71MB066 Includes pilot gas filter. Use with
nominal 30MV thermocouple.
P545
MODEL NO.: C591A
TUBE SIZE: 1/4″ O.D.
P/N: EF53FB020

P549

348
IGNITION SYSTEMS
IGNITION SYSTEM ACCESSORIES
RESISTORS LOW PRESSURE SWITCH

OHMS
RESIST- WATTS P/N
ANCE
4 20 HT21AU004 PRESS.
RATING P/N
5 20 HT21AU020 SETTING
3 8 5593D5 1 AMP 2″ WC HK02LB005
1 AMP 6″ WC HK02LB018
P550
P554
Resistors and resistance wire are required on some units to
These low pressure switches are used in ignition circuits to
reduce the voltage to ignition glow coils. Refer to unit installation
interrupt power when gas pressure is low or gas service to unit
and service instructions.
is shut down. Switch has 1/8″ NPT connection on underside.

RESISTANCE WIRE COMBUSTION BLOWER ASSEMBLY

OHMS LENGTH
P/N
PER FT. (in.)
.380 156 48DA660025

P551

This package contains stainless resistance wire used in reducing


the 24 volt power source to nominal 9-11 volts required on some
glow coil igniters. Instruction sheet included. P317-1
100
• 100 CFM MAX.
90
IGNITION LEADS 80 • 230 VOLT
70
HIGH VOLTAGE IGNITION LEAD 60 • 1/10 H.P.
50
Silicone insulated wire for ignition • PSC MOTOR
40
systems where high temperature, 30
moisture resistant ignition lead is 20
• 3450 RPM
required on outdoor equipment. 10
P/N: 48DA660019
0
P552 0 .2 .4 .6 .8 .10 .12 .14 .16 .18 .20 .22

END WIRE
P/N
CONNECTIONS LENGTH (in.)
SPK. PLUG/RING TERM. 20 48MA403742
SPARK PLUG 24 B0805050
Q.C./PIN TERM. 24 48DD410452
NONE 27 301286-702
QUICK CONNECT 24 RM680002

• PENN SENSOR LEAD


• SILICONE-INSULATED
COPPER CONDUCTOR
• FOR USE WITH LH33CM600
SPARK MODULE 64
• 60 CFM MAX.
P553 56
• QUICK CONNECTS 48
• 230 VOLT
40
32 • 1/80 H.P
24
Q.C. Q.C. PENN LENGTH 16 • SHADED POLE MOTOR
P/N
TYPE INSULATED NO. (in.) 8
STRAIGHT YES Y57JH27 27 RM680003 0
• 3200 RPM
0 .06 .12 .18 .24 .30 .36 .42 .48 .54 .60 .66
ST./FLAG NO Y57HJ24 24 58EGB0805041 P/N: LA25UZ001

349
IGNITION SYSTEMS
OIL BURNER COMPONENTS
OIL PUMPS PRIMARY CONTROLS
• PROVIDES NON-RECYCLING
CONTROL OF AN
INTERMITTENT IGNITION OIL
BURNER SYSTEM
• SOLID STATE FLAME SENSING
CIRCUIT
• MOUNTS ON STANDARD 4 x 4
BOX
• 45 SECOND SAFETY SWITCH
P555 TIMING
P556
• MANUAL RESET REQUIRED
SUNSTRAND WEBSTER P559
AFTER SAFETY SHUTDOWN
• COMPACT SIZE • COMPACT SIZE • USE WITH HH79AY060 CAD CELL
• 5/16″ DIA. SHAFT • 5/16″ DIA. SHAFT • INTEGRAL TRANSFORMER SUPPLIES 24V POWER TO
CONTROL CIRCUIT
• INTEGRAL BLEED FITTING • INTEGRAL BLEED FITTING MODEL NO: R8184G
FOR EASY START UP FOR EASY START UP
P/N: HH11AZ070
PUMP STAGES PUMP RPM P/N
SUNSTRAND
1 1725 58HH680027
2 1725 58HH680029
• SOLID STATE FLAME SENSING
CIRCUIT
1 3450 58HH680001
• MOUNTS ON STANDARD 4 x 4
2 3450 58HH680002 BOX
WEBSTER • 45 SECOND SAFETY SWITCH
1 1725 58HH680028 TIMING
2 1725 58HH680030 • USE WITH HH79AY060 CAD
1 3450 58HH680025 CELL
2 3450 58HH680026 • MANUAL RESET REQUIRED
P560 AFTER SAFETY SHUTDOWN
OIL BURNER IGNITION TRANSFORMER • INTEGRAL 40VA TRANSFORMER
• PROVIDES CONTROL OF AN INTERMITTENT IGNITION OIL
BURNER AND POWER FOR A LOW VOLTAGE COOLING
• 115 VOLT CONTROL CIRCUIT
• 10,000 VOLT SECONDARY • EXTRA “Y” AND “G” CONNECTIONS FOR COOLING
MODEL NO: R8184M
• 23 MA
P/N: HH11AZ067
P557

• STACK MOUNTED
BASE (in.) MOUNTING
P/N • MANUAL RESET
WIDTH LENGTH CENTERS (in.)
4-7/16 5-7/16 3-1/4 x 4-1/4 HT08BR115 • FOR USE WITH 2 OR 3 WIRE
CONTROL
4-3/8 5-5/16 3-1/2 x 2-3/4 HT08BR116
• MANUAL TRIP SAFETY SWITCH
COUPLINGS • INTERRUPTED IGNITION
MODEL NO: RA117A

P561
P/N: HH11AZ040

• FAST RESPONSE TIME


• EASY MOUNTING FOR
ACCURATE SIGHTING
P558
• EASY REPLACEMENT OF
PLUG IN CELL
ENDS (in.) LENGTH (in.) P/N • CAD CELL
1/2 x 5/16 4-1/4 58HH680034 HERMETICALLY SEALED
MODEL NO: C554
P1208
P/N: 956-154

350
IGNITION SYSTEMS
OIL BURNER COMPONENTS
PRIMARY CONTROLS
P/N P691-R7184 Interrupted Electronic Oil Primary P/N P691-R818RG Protectorelay/Oil Burner Control

P4322

P4324
• COMPATIBLE WITH HYDRONIC AND FORCED AIR
APPLICATIONS. • PRIMARY CONTROL OPERATES THE OIL BURNER, OIL
• AVAILABLE IN 15 AND 30-SECOND LOCKOUT TIMES. VALVE, AND IGNITION TRANSFORMER IN A RESPONSE
• SAFE START CHECK. FOR A CALL FOR HEAT FROM THE THERMOSTAT.
• STATUS INDICATOR LIGHT MONITORS BURNER • LOCKOUT INDICATION LIGHTS REDUCE UNNECES-
FLAME STATUS AND SYSTEM LOCKOUT. SARY SERVICE CALLS.
• USES PROVEN FLAME DETECTION AND • TAMPER RESISTANT, RUSTPROOF, SCRATCH
MONITORING SYSTEMS. RESISTANT COVER.
• OPTIONAL DELAY ON VALVE, BLOWER OFF DELAY • HIGHEST PERFORMANCE AND RELIABILITY MAKE IT
MODELS. THE PREFERENCE OF ORIGINAL EQUIPMENT
MANUFACTURERS.

HONEYWELL
PART NUMBER DESCRIPTION
PART NUMBER
P691-R7184A-P R7184A1026 Interrupted Electronic Oil Primary
P691-R7184A-SS R7184A1042 Interrupted Electronic Oil Primary
P691-R7184U R7184U1012 Universal Interrupted Electronic Oil Primary
P691-R8484G R8184G4009 Protectorelay/Oil Burner Control

SOLID-STATE OIL IGNITER


P/N P691-S7184A Solid State Oil Igniter
• THE SOLID STATE OIL IGNITER IS A LINE VOLTAGE IGNITER FOR
RESIDENTIAL OIL FIRED BURNERS, FORCED AIR FURNACES, BOILERS,
AND WATER HEATERS.
• MOUNTS ON BURNER HOUSING.
• DIAGNOSTIC LED INDICATES WHEN THE IGNITER HAS BEEN ENERGIZED.
• IGNITER CAN BE USED IN AN INTERMITTENT (CONTINUOUS) OR
INTERRUPTED MODE OF OPERATION.
PART HONEYWELL
DESCRIPTION
NUMBER PART NUMBER
P4323
P691-S7184A S7184A1023 Solid State Oil Igniter

351