Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
NOTES
LINES IDENTIFICATION
PROCESS/UTILITY LINE
BASKET STRAINER
ELECTRICAL LINE GATE VALVE
B BURIED
INSTRUMENT GAS/ FLAME ARRESTOR
PNEUMATIC LINE 1. HIGH POINT VENT AND LOW POINT DRAIN NOT SHOWN ON P&ID SHALL BE SHOWN ON PIPING
GLOBE VALVE
ISOMETRIC / GENERAL ARRANGEMENT DRAWINGS .
ELECTRICAL TRACED LINE ANGLE VALVE
ST STEAM TRAP
2. ALL SAFETY VALVES DISCHARGE & EQUIPMENT DEPRESSURIZING LINES SHALL BE FREE DRAINING
CHECK VALVE
X X X CAPILLARY LINE ANGLE BALL VALVE TO VENT HEADER AND HAVE NO POCKETS UPTO AND INCLUDING HEADERS.
UNION
VENDOR LIMIT LINE
BUTTERFLY VALVE ANGLE CHOKE VALVE 3. ALL ISOLATION VALVES IN TAPPINGS OF INSTRUMENTS (SUCH AS PRESSURE, LEVEL AND FLOW
5. ALL INSTRUMENTS SHALL BE PROVIDED WITH ISOLATION VALVES FOR MAINTENANCE PURPOSE.
FUTURE THREE WAY VALVE
B ADAPTER (TUBING PIPE) IT SHOULD BE ENSURED THAT THESE VALVES SHALL BE EASILY ACCESSIBLE.
BALL VALVE
o o o
SS TUBING (PROCESS)
THREE WAY CONTROL VALVE
NEEDLE VALVE 6. DRAINS OF LEVEL INSTRUMENTS (NON-SOUR SERVICES) SHALL BE PIPED TO NEAREST DECK
FLOW ELEMENT ORIFICE/
DRAIN FUNNEL WITH 1/2" TUBE PIPE.
SCOPE OF WORK/LINE RATING
RESTRICTION ORIFICE
CHANGE (WITH PIPING SPEC.
CONTINUOUS DRAIN
DESIGNATION) SPRING LOADED VALVE 7. FOR PUMPS HANDLING SWEET LIQUID, CASING VENTS, DRAINS AND BASE PLATE DRAINS SHALL
TURBINE METER
VANES CONTROL VALVE BE PIPED WITH VALVE TO NEAREST DECK DRAIN FUNNEL. CASING DRAINS AND VENT FOR
DIAPHRAGM VALVE PUMPS IN SOUR SERVICE SHALL BE PIPED TO CLOSED DRAIN HEADER RESPECTIVELY.
JOHANUSMIRECFT
CONTROL VALVE WITH HAND WHEEL
PANEL MOUNTED / S 10. ALL LIQUID SAMPLE POINTS EXCEPT FOR WELL FLUID SAMPLES SHALL BE TAKEN FROM CENTER OF
SONIC METER OPEN DECK DRAIN
CENTRAL CONTROL PANEL THE PIPE. WELL FLUID SAMPLES SHALL BE TAKEN FROM VERTICAL PORTION OF THE PIPE. ALL GAS
SELF ACTUATED PCV (DOWN STREAM) (WITH LIQUID SEAL)
SAMPLES SHALL BE TAKEN FROM TOP OF THE PIPE.
BACK PANEL MOUNTED PILOT TUBE OFF CONNECTIONS SHALL BE SW (SOCKET WELD) UNLESS OTHERWISE SPEIFIED.
1/2"
FUNCTION BLOCK PI PI
D A ANALYSER
3/4"
*
3/4"
SP
SPECIALITY ITEM
INTERLOCK BUTTERFLY CONTROL VALVE
LO PI PI
3/4"
FILTER
1/2"
FLEXIBLE HOSE
1/2"
RUNNING LIGHT,LOCAL PILOT VALVE (XPV) 3/4"
LO
CAP (THREADED) RAIN CAP
SLOPE(DOWN WARD)
RUNNING LIGHT,PANEL 11.3
PIPING
INSTR.
HAMMER BLIND
BLIND FLANGE
I SHUT DOWN
RUNNING LIGHT,LOCAL PANEL 1/2"
SPECTACLE BLIND
CAP (WELDED)
FLANGE PDI
SOLENOID VALVE(2 WAY) LO/LC NORMALY LOCK OPEN INTERCHANGABLE TO LC PDI
T-TYPE STRAINER
ADJUSTABLE CHOKE
NC NORMALY CLOSED
Y-TYPE STRAINER
NO NORMALLY OPEN
FUSIBLE PLUG
S
JOHANUSMIRECFT