NOTES

1. STANDARD MANHOLE TO BE USED


FOR PIPES 24" AND LESS.
2. PRECAST CONCRETE STRUCTURES
SHALL HAVE STRENGTH OF 4000 PSI.
3. STANDARD MANHOLE DEPTH = 8’
TOP OF FRAME TO INVERT.
4. LATERAL LINES TO MATCH TOP OF
INLET PIPE AT MANHOLE.
5. ALL INTERIOR JOINTS AND CONNECT-
IONS SHALL BE WATER TIGHT,
AND GROUTED WITH NON-SHRINK
GROUT.
6. ALL MANHOLES SHALL BE VACUUM
TESTED PRIOR TO ACCEPTANCE.
7. BOND ALL MANHOLE SECTION
CAST IRON GROOVES WITH MASTIC SEAL.
FRAME AND COVER 8. IF END OF LINE MANHOLE, STEPS SHALL
SEE STD. DWG. 209 BE LOCATED ON DOWNSTREAM SIDE AND
CHANNEL SHALL BE CONSTRUCTED FULL
WIDTH OF INTERIOR.

EXTERIOR GROUTING
OF FRAME
18" to 24"
RISER RINGS-MAX. 6"

PLACE STEPS UPSTREAM ECCENTRIC


ON MAIN CHANNEL CONE SECTION
36"

BOND ALL JOINTS WITH


MASTIC SEAL WITH KEY-
RELINER DROP BOWL
LOCK JOINTS
OR EQUIVALENT

SECTION
1’ to 4’

SECURE TO MANHOLE
WITH STAINLESS STEEL
FASTENERS

PIPE COUPLER

FASTENER CONNECTIONS TO MANHOLE


TO BE A MIN OF 6" FROM ANY JOINT
BASE SECTION
2’ to 4’

6" MAX DIA. PVC PIPE SECURED TO


STRUCTUREWITH STAINLESS STEEL
FASTENERSAT 4’ INTERVALS (MIN. OF 2)

MANHOLE BASE
CHANNEL MANHOLE
SEE STD.
TO DIRECT FLOW AS
DRAWING 203
REQUIRED

REVISIONS: SCALE: N.T.S.

City of DATE: May 2007

INSIDE APPROVED
Newberg DROP MANHOLE
BY:
D. Danicic

PUBLIC WORKS ENGINEERING DIVISION STANDARD


414 E. FIRST STREET NEWBERG, OREGON 97132
PHONE 503-537-1240 - FAX 503-537-1277