Sei sulla pagina 1di 1389

ZXG10 iBSC

Base Station Controller


Performance Counter Reference (Volume I)

Version 6.20.10

ZTE CORPORATION
ZTE Plaza, Keji Road South,
Hi-Tech Industrial Park,
Nanshan District, Shenzhen,
P. R. China
518057
Tel: (86) 755 26771900 800-9830-9830
Fax: (86) 755 26772236
URL: http://support.zte.com.cn
E-mail: doc@zte.com.cn
LEGAL INFORMATION

Copyright © 2006 ZTE CORPORATION.

The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by
contractual confidentiality obligations.

All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.

This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.

ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.

ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.

Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.

The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History

Date Revision No. Serial No. Reason for Issue


Jun 25, 2009 R1.0 sjzl20093541 First edition
ZTE CORPORATION
Values Your Comments & Suggestions!
Your opinion is of great value and will help us improve the quality of our product
documentation and offer better services to our customers.
Please fax to: (86) 755-26772236; or mail to Technical Delivery Department, ZTE
University, Dameisha, Yantian District, Shenzhen, Guangdong, P.R. China 518083.
Thank you for your cooperation!

Document
ZXG10 iBSC (V6.20.10) Base Station Controller Performance Counter Reference (Volume I)
Name
Document Revision
Product Version V6.20.10 R1.0
Number
Equipment
Serial No. sjzl20093541
Installation Date

Presentation:
(Introductions, Procedures, Illustrations, Completeness, Level of Detail, Organization,
Appearance)
… Good … Fair … Average … Poor … Bad … N/A

Your evaluation Accessibility:


of this
(Contents, Index, Headings, Numbering, Glossary)
documentation
… Good … Fair … Average … Poor … Bad … N/A

Intelligibility:
(Language, Vocabulary, Readability & Clarity, Technical Accuracy, Content)
… Good … Fair … Average … Poor … Bad … N/A

Please check the suggestions which you feel can improve this documentation:
… Improve the overview/introduction … Make it more concise/brief
… Improve the Contents … Add more step-by-step procedures/tutorials
… Improve the organization … Add more troubleshooting information
… Include more figures … Make it less technical
Your … Add more examples … Add more/better quick reference aids
suggestions for … Add more detail … Improve the index
improvement of
this … Other suggestions
documentation __________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
# Please feel free to write any comments on an attached sheet.

If you wish to be contacted regarding your comments, please complete the following:
Name Company
Postcode Address
Telephone E-mail
This page is intentionally blank.
Contents

About This Manual ............................................................ i


Purpose ................................................................................ i
Intended Audience ................................................................. i
Prerequisite Skill and Knowledge .............................................. i
What Is in This Manual ........................................................... i
Related Documentation.......................................................... ii
Conventions ........................................................................ iii
How to Get in Touch............................................................. iv

Declaration of RoHS Compliance..................................... v

Chapter 1.......................................................................... 1

PS Basic Measurement (BSC).......................................... 1


Overview ............................................................................. 1
PS Basic Measurement (BSC) Counter Index ............................. 1
C900030001 ........................................................................ 1
C900030002 ........................................................................ 2

Chapter 2.......................................................................... 3

PS Basic Measurement (Cell) .......................................... 3


Overview ............................................................................. 3
PS Basic Measurement (Cell) Counter Index.............................. 3
C900040001 ...................................................................... 12
C900040002 ...................................................................... 13
C900040003 ...................................................................... 14
C900040004 ...................................................................... 15
C900040005 ...................................................................... 15
C900040006 ...................................................................... 16
C900040007 ...................................................................... 16
C900040008 ...................................................................... 17
C900040009 ...................................................................... 17
C900040010 ...................................................................... 17
C900040011.......................................................................18
C900040012.......................................................................19
C900040013.......................................................................19
C900040014.......................................................................20
C900040015.......................................................................20
C900040016.......................................................................21
C900040017.......................................................................21
C900040018.......................................................................21
C900040019.......................................................................21
C900040020.......................................................................22
C900040021.......................................................................22
C900040022.......................................................................23
C900040023.......................................................................24
C900040024.......................................................................24
C900040025.......................................................................24
C900040026.......................................................................26
C900040027.......................................................................27
C900040028.......................................................................27
C900040029.......................................................................27
C900040030.......................................................................28
C900040031.......................................................................28
C900040032.......................................................................28
C900040033.......................................................................29
C900040034.......................................................................29
C900040035.......................................................................29
C900040036.......................................................................30
C900040037.......................................................................30
C900040038.......................................................................30
C900040039.......................................................................31
C900040040.......................................................................31
C900040041.......................................................................31
C900040042.......................................................................32
C900040043.......................................................................32
C900040044.......................................................................32
C900040045.......................................................................33
C900040046.......................................................................33
C900040047.......................................................................33
C900040048.......................................................................34
C900040049.......................................................................34
C900040050 ...................................................................... 35
C900040051 ...................................................................... 35
C900040052 ...................................................................... 36
C900040053 ...................................................................... 37
C900040054 ...................................................................... 37
C900040055 ...................................................................... 38
C900040056 ...................................................................... 38
C900040057 ...................................................................... 39
C900040058 ...................................................................... 39
C900040059 ...................................................................... 40
C900040060 ...................................................................... 40
C900040061 ...................................................................... 41
C900040062 ...................................................................... 42
C900040063 ...................................................................... 42
C900040064 ...................................................................... 43
C900040065 ...................................................................... 44
C900040066 ...................................................................... 44
C900040067 ...................................................................... 45
C900040068 ...................................................................... 45
C900040069 ...................................................................... 46
C900040070 ...................................................................... 46
C900040071 ...................................................................... 47
C900040072 ...................................................................... 48
C900040073 ...................................................................... 48
C900040074 ...................................................................... 49
C900040075 ...................................................................... 50
C900040076 ...................................................................... 50
C900040077 ...................................................................... 51
C900040078 ...................................................................... 51
C900040079 ...................................................................... 52
C900040080 ...................................................................... 52
C900040081 ...................................................................... 53
C900040082 ...................................................................... 53
C900040083 ...................................................................... 54
C900040084 ...................................................................... 54
C900040085 ...................................................................... 54
C900040086 ...................................................................... 55
C900040087 ...................................................................... 55
C900040088 ...................................................................... 56
C900040089.......................................................................56
C900040090.......................................................................56
C900040091.......................................................................57
C900040092.......................................................................57
C900040093.......................................................................58
C900040094.......................................................................58
C900040095.......................................................................59
C900040096.......................................................................59
C900040097.......................................................................59
C900040098.......................................................................60
C900040099.......................................................................60
C900040100.......................................................................60
C900040101.......................................................................61
C900040102.......................................................................61
C900040103.......................................................................62
C900040104.......................................................................62
C900040105.......................................................................62
C900040106.......................................................................63
C900040107.......................................................................63
C900040108.......................................................................63
C900040109.......................................................................64
C900040110.......................................................................65
C900040111.......................................................................65
C900040112.......................................................................66
C900040113.......................................................................67
C900040114.......................................................................67
C900040115.......................................................................68
C900040116.......................................................................68
C900040117.......................................................................69
C900040118.......................................................................69
C900040119.......................................................................70
C900040120.......................................................................70
C900040121.......................................................................71
C900040122.......................................................................72
C900040123.......................................................................72
C900040124.......................................................................73
C900040125.......................................................................73
C900040126.......................................................................74
C900040127.......................................................................74
C900040128 ...................................................................... 75
C900040129 ...................................................................... 75
C900040130 ...................................................................... 76
C900040131 ...................................................................... 76
C900040132 ...................................................................... 77
C900040133 ...................................................................... 77
C900040134 ...................................................................... 78
C900040135 ...................................................................... 78
C900040136 ...................................................................... 78
C900040137 ...................................................................... 79
C900040138 ...................................................................... 79
C900040139 ...................................................................... 79
C900040140 ...................................................................... 80
C900040141 ...................................................................... 80
C900040142 ...................................................................... 81
C900040143 ...................................................................... 82
C900040144 ...................................................................... 82
C900040145 ...................................................................... 83
C900040146 ...................................................................... 84
C900040147 ...................................................................... 85
C900040148 ...................................................................... 85
C900040149 ...................................................................... 86
C900040150 ...................................................................... 87
C900040151 ...................................................................... 88
C900040152 ...................................................................... 88
C900040153 ...................................................................... 89
C900040154 ...................................................................... 89
C900040155 ...................................................................... 90
C900040156 ...................................................................... 91
C900040157 ...................................................................... 91
C900040158 ...................................................................... 92
C900040159 ...................................................................... 92
C900040160 ...................................................................... 94
C900040161 ...................................................................... 94
C900040162 ...................................................................... 95
C900040163 ...................................................................... 95
C900040164 ...................................................................... 96
C900040165 ...................................................................... 97
C900040166 ...................................................................... 97
C900040167.......................................................................98
C900040168.......................................................................98
C900040169.......................................................................99
C900040170.......................................................................99
C900040171.......................................................................99
C900040172..................................................................... 100
C900040173..................................................................... 100
C900040174..................................................................... 100
C900040175..................................................................... 101
C900040176..................................................................... 101
C900040177..................................................................... 101
C900040178..................................................................... 102
C900040179..................................................................... 102
C900040180..................................................................... 102
C900040181..................................................................... 103
C900040182..................................................................... 103
C900040183..................................................................... 103
C900040184..................................................................... 104
C900040185..................................................................... 104
C900040186..................................................................... 104
C900040187..................................................................... 105
C900040188..................................................................... 105
C900040189..................................................................... 105
C900040190..................................................................... 106
C900040191..................................................................... 106
C900040192..................................................................... 107
C900040193..................................................................... 107
C900040194..................................................................... 107
C900040195..................................................................... 108
C900040196..................................................................... 108
C900040197..................................................................... 108
C900040198..................................................................... 109
C900040199..................................................................... 109
C900040200..................................................................... 109
C900040201..................................................................... 110
C900040202..................................................................... 110
C900040203..................................................................... 110
C900040204..................................................................... 111
C900040205..................................................................... 111
C900040206 .................................................................... 111
C900040207 .................................................................... 112
C900040208 .................................................................... 112
C900040209 .................................................................... 112
C900040210 .................................................................... 113
C900040211 .................................................................... 113
C900040212 .................................................................... 113
C900040213 .................................................................... 114
C900040214 .................................................................... 114
C900040215 .................................................................... 114
C900040216 .................................................................... 115
C900040217 .................................................................... 115
C900040218 .................................................................... 115
C900040219 .................................................................... 116
C900040220 .................................................................... 116
C900040221 .................................................................... 116
C900040222 .................................................................... 117
C900040223 .................................................................... 117
C900040224 .................................................................... 117
C900040225 .................................................................... 118

Chapter 3...................................................................... 119

CPU Load Measurement...............................................119


Overview ......................................................................... 119
CPU Load Measurement Counter Index................................. 119
C900050001 .................................................................... 119
C900050002 .................................................................... 120

Chapter 4...................................................................... 121

CS Basic Measurement ................................................121


Overview ......................................................................... 121
CS Basic Measurement Counter Index .................................. 121
C900060001 .................................................................... 131
C900060002 .................................................................... 131
C900060003 .................................................................... 132
C900060004 .................................................................... 133
C900060005 .................................................................... 133
C900060006 .................................................................... 134
C900060007 .................................................................... 135
C900060008..................................................................... 136
C900060009..................................................................... 136
C900060010..................................................................... 137
C900060011..................................................................... 138
C900060012..................................................................... 138
C900060013..................................................................... 141
C900060014..................................................................... 142
C900060015..................................................................... 142
C900060016..................................................................... 143
C900060017..................................................................... 144
C900060018..................................................................... 145
C900060019..................................................................... 145
C900060020..................................................................... 147
C900060021..................................................................... 148
C900060022..................................................................... 149
C900060023..................................................................... 149
C900060024..................................................................... 149
C900060025..................................................................... 150
C900060026..................................................................... 151
C900060027..................................................................... 151
C900060028..................................................................... 152
C900060029..................................................................... 152
C900060030..................................................................... 153
C900060031..................................................................... 154
C900060032..................................................................... 154
C900060033..................................................................... 155
C900060034..................................................................... 155
C900060035..................................................................... 156
C900060036..................................................................... 156
C900060037..................................................................... 157
C900060038..................................................................... 157
C900060039..................................................................... 158
C900060040..................................................................... 158
C900060041..................................................................... 159
C900060042..................................................................... 159
C900060043..................................................................... 160
C900060044..................................................................... 160
C900060045..................................................................... 161
C900060046..................................................................... 162
C900060047 .................................................................... 162
C900060048 .................................................................... 163
C900060049 .................................................................... 164
C900060050 .................................................................... 164
C900060051 .................................................................... 165
C900060052 .................................................................... 166
C900060053 .................................................................... 168
C900060054 .................................................................... 168
C900060055 .................................................................... 169
C900060056 .................................................................... 169
C900060057 .................................................................... 169
C900060058 .................................................................... 170
C900060059 .................................................................... 170
C900060060 .................................................................... 170
C900060061 .................................................................... 171
C900060062 .................................................................... 171
C900060063 .................................................................... 171
C900060064 .................................................................... 171
C900060065 .................................................................... 172
C900060066 .................................................................... 172
C900060067 .................................................................... 172
C900060068 .................................................................... 173
C900060069 .................................................................... 173
C900060070 .................................................................... 173
C900060071 .................................................................... 174
C900060072 .................................................................... 174
C900060073 .................................................................... 174
C900060074 .................................................................... 174
C900060075 .................................................................... 175
C900060076 .................................................................... 175
C900060077 .................................................................... 175
C900060078 .................................................................... 176
C900060079 .................................................................... 176
C900060080 .................................................................... 176
C900060081 .................................................................... 177
C900060082 .................................................................... 177
C900060083 .................................................................... 177
C900060084 .................................................................... 178
C900060085 .................................................................... 178
C900060086..................................................................... 178
C900060087..................................................................... 179
C900060088..................................................................... 179
C900060089..................................................................... 180
C900060090..................................................................... 180
C900060091..................................................................... 180
C900060092..................................................................... 181
C900060093..................................................................... 181
C900060094..................................................................... 182
C900060095..................................................................... 183
C900060096..................................................................... 184
C900060097..................................................................... 184
C900060098..................................................................... 185
C900060099..................................................................... 185
C900060100..................................................................... 186
C900060101..................................................................... 187
C900060102..................................................................... 187
C900060103..................................................................... 188
C900060104..................................................................... 188
C900060105..................................................................... 189
C900060106..................................................................... 189
C900060107..................................................................... 190
C900060108..................................................................... 190
C900060109..................................................................... 190
C900060110..................................................................... 191
C900060111..................................................................... 191
C900060112..................................................................... 192
C900060113..................................................................... 192
C900060114..................................................................... 192
C900060115..................................................................... 193
C900060116..................................................................... 193
C900060117..................................................................... 194
C900060118..................................................................... 194
C900060119..................................................................... 194
C900060120..................................................................... 195
C900060121..................................................................... 196
C900060122..................................................................... 197
C900060123..................................................................... 197
C900060124..................................................................... 197
C900060125 .................................................................... 198
C900060126 .................................................................... 198
C900060127 .................................................................... 199
C900060128 .................................................................... 199
C900060129 .................................................................... 200
C900060130 .................................................................... 201
C900060131 .................................................................... 201
C900060132 .................................................................... 201
C900060133 .................................................................... 202
C900060134 .................................................................... 202
C900060135 .................................................................... 202
C900060136 .................................................................... 203
C900060137 .................................................................... 203
C900060138 .................................................................... 203
C900060139 .................................................................... 204
C900060140 .................................................................... 204
C900060141 .................................................................... 205
C900060142 .................................................................... 205
C900060143 .................................................................... 206
C900060144 .................................................................... 206
C900060145 .................................................................... 207
C900060146 .................................................................... 207
C900060147 .................................................................... 208
C900060148 .................................................................... 208
C900060149 .................................................................... 209
C900060150 .................................................................... 209
C900060151 .................................................................... 209
C900060152 .................................................................... 210
C900060153 .................................................................... 211
C900060154 .................................................................... 211
C900060155 .................................................................... 211
C900060156 .................................................................... 212
C900060157 .................................................................... 212
C900060158 .................................................................... 213
C900060159 .................................................................... 214
C900060160 .................................................................... 214
C900060161 .................................................................... 215
C900060162 .................................................................... 215
C900060163 .................................................................... 215
C900060164..................................................................... 216
C900060165..................................................................... 216
C900060166..................................................................... 217
C900060167..................................................................... 217
C900060168..................................................................... 218
C900060169..................................................................... 218
C900060170..................................................................... 219
C900060171..................................................................... 219
C900060172..................................................................... 220
C900060173..................................................................... 220
C900060174..................................................................... 220
C900060175..................................................................... 221
C900060176..................................................................... 221
C900060177..................................................................... 222
C900060178..................................................................... 222
C900060179..................................................................... 223
C900060180..................................................................... 223
C900060181..................................................................... 224
C900060182..................................................................... 224
C900060183..................................................................... 225
C900060184..................................................................... 225
C900060185..................................................................... 226
C900060186..................................................................... 226
C900060187..................................................................... 226
C900060188..................................................................... 227
C900060189..................................................................... 227
C900060190..................................................................... 228
C900060191..................................................................... 228
C900060192..................................................................... 229
C900060193..................................................................... 229
C900060194..................................................................... 230
C900060195..................................................................... 230
C900060196..................................................................... 231
C900060197..................................................................... 231
C900060198..................................................................... 232
C900060199..................................................................... 232
C900060200..................................................................... 232
C900060201..................................................................... 233
C900060202..................................................................... 233
C900060203 .................................................................... 234
C900060204 .................................................................... 234
C900060205 .................................................................... 235
C900060206 .................................................................... 235
C900060207 .................................................................... 236
C900060208 .................................................................... 236
C900060209 .................................................................... 236
C900060210 .................................................................... 237
C900060211 .................................................................... 237
C900060212 .................................................................... 238
C900060213 .................................................................... 238
C900060214 .................................................................... 239
C900060215 .................................................................... 240
C900060216 .................................................................... 240
C900060217 .................................................................... 241
C900060218 .................................................................... 241
C900060219 .................................................................... 241
C900060220 .................................................................... 242
C900060221 .................................................................... 243
C900060222 .................................................................... 244
C900060223 .................................................................... 244
C900060224 .................................................................... 245
C900060225 .................................................................... 245
C900060226 .................................................................... 246
C900060227 .................................................................... 246
C900060228 .................................................................... 246
C900060229 .................................................................... 247
C900060230 .................................................................... 247
C900060231 .................................................................... 248
C900060232 .................................................................... 248
C900060233 .................................................................... 248
C900060234 .................................................................... 249
C900060235 .................................................................... 249
C900060236 .................................................................... 250
C900060237 .................................................................... 250
C900060238 .................................................................... 250
C900060239 .................................................................... 251
C900060240 .................................................................... 251
C900060241 .................................................................... 252
C900060242..................................................................... 252
C900060243..................................................................... 253
C900060244..................................................................... 253
C900060245..................................................................... 254

Chapter 5......................................................................255

Configuration Management Infomation Basic


Measurement ...............................................................255
Overview ......................................................................... 255
Configuration Management Infomation Basic Measurement Counter
Index .............................................................................. 255
C900090001..................................................................... 256
C900090002..................................................................... 256
C900090003..................................................................... 256
C900090004..................................................................... 256
C900090005..................................................................... 257
C900090006..................................................................... 257
C900090007..................................................................... 257
C900090008..................................................................... 257
C900090009..................................................................... 258

Appendix A ...................................................................259

Abbreviations ...............................................................259

Appendix B ...................................................................263

Figures..........................................................................263

Tables ...........................................................................271

Index ............................................................................273
About This Manual

Purpose
This manual provides procedures and guidelines that support the
operation of the ZXG10 iBSC (V6.20.10).

Intended Audience
This manual is intended for engineers and technicians who
perform operation activities on the ZXG10 iBSC (V6.20.10).

Prerequisite Skill and Knowledge


To use this manual effectively, users should have a general
understanding of wireless telecommunications technology.
Familiarity with the following is helpful:
„ ZXG10 system and its various components
„ GSM BSS components and processes
„ Local operating procedures

What Is in This Manual


This manual contains three volumes, including the following
sections:

TABLE 1 – M ANUAL SUMMARY

Section Summary
Chapter 1, PS Basic Introduces the detailed information about
Measurement (BSC) counters related to PS basic measurement
(BSC).
Chapter 2, PS Basic Introduces the detailed information about
Measurement (Cell) counters related to PS basic measurement
(Cell).
Chapter 3, CPU Load Introduces the detailed information about

Confidential and Proprietary Information of ZTE CORPORATION i


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Section Summary
Measurement counters related to CPU load
measurement.
Chapter 4, CS Basic Introduces the detailed information about
Measurement counters related to CS basic
measurement.
Chapter 5, Introduces the detailed information about
Configuration counters related to configuration
Management management information basic
Information Basic measurement.
Measurement
Appendix A, Lists all the abbreviations used in this
Abbreviations manual.

Appendix B, Figures Lists all the figures and tables used in this
and Tables manual.

Index Index of terms and definitions appeared in


this manual.

Related Documentation
The following documentation is related to this manual:
„ ZXG10 iBSC (V6.20.10) Base Station Controller
Documentation Guide
„ ZXG10 iBSC (V6.20.10) Base Station Controller System
Description
„ ZXG10 iBSC (V6.20.10) Base Station Controller Hardware
Description
„ ZXG10 iBSC (V6.20.10) Base Station Controller Hardware
Installation Guide
„ ZXG10 iBSC (V6.20.10) Base Station Controller Routine
Maintenance
„ ZXG10 iBSC (V6.20.10) Base Station Controller Emergency
Maintenance
„ ZXG10 iBSC (V6.20.10) Base Station Controller
Troubleshooting
„ ZXG10 iBSC (V6.20.10) Base Station Controller KPI
Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem OMM
Software Installation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Initial
Configuration Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Feature
Configuration Guide

ii Confidential and Proprietary Information of ZTE CORPORATION


About This Manual

„ ZXG10 BSS (V6.20.10) Base Station Subsystem Radio


Parameters Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Ground
Parameters Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem MML
Command Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Signaling
Tracing Operation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Diagnosis
Test Operation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Alarm
Handling Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Notification
Handling Reference

Conventions
Typographical ZTE documents employ the following typographical conventions.
Conventions
TABLE 2 - TYPOGRAPHIC AL CONVENTIONS

Typeface Meaning
Italics References to other Manuals and documents.
“Quotes” Links on screens.
Bold Menus, menu options, function names, input
fields, radio button names, check boxes, drop-
down lists, dialog box names, window names.
CAPS Keys on the keyboard and buttons on screens
and company name.
Constant width Text that you type, program code, files and
directory names, and function names.
[] Optional parameters.
{} Mandatory parameters.
| Select one of the parameters that are delimited
by it.
Note: Provides additional information about a
certain topic.
Checkpoint: Indicates that a particular step needs
to be checked before proceeding further.
Tip: Indicates a suggestion or hint to make things
easier or more productive for the reader.

Confidential and Proprietary Information of ZTE CORPORATION iii


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

TABLE 3 - MOUSE OPERATION CONVENTIONS


Mouse
Operation Typeface Meaning
Conventions Click Refers to clicking the primary mouse button (usually
the left mouse button) once.
Double-click Refers to quickly clicking the primary mouse button
(usually the left mouse button) twice.
Right-click Refers to clicking the secondary mouse button
(usually the right mouse button) once.
Drag Refers to pressing and holding a mouse button and
moving the mouse.

How to Get in Touch


The following sections provide information on how to obtain
support for the documentation and the software.
Customer If you have problems, questions, comments, or suggestions
Support regarding your product, contact us by e-mail at
support@zte.com.cn. You can also call our customer support
center at (86) 755 26771900 and (86) 800-9830-9830.
Documentation ZTE welcomes your comments and suggestions on the quality
Support and usefulness of this document. For further questions,
comments, or suggestions on the documentation, you can
contact us by e-mail at doc@zte.com.cn; or you can fax your
comments and suggestions to (86) 755 26772236. You can also
browse our website at http://support.zte.com.cn, which contains
various interesting subjects like documentation, knowledge base,
forum and service request.

iv Confidential and Proprietary Information of ZTE CORPORATION


Declaration of RoHS
Compliance

To minimize the environmental impact and take more


responsibility to the earth we live, this document shall serve as
formal declaration that the ZXG10 iBSC (V6.20.10) Base Station
Controller manufactured by ZTE CORPORATION is in compliance
with the Directive 2002/95/EC of the European Parliament -
RoHS (Restriction of Hazardous Substances) with respect to the
following substances:
„ Lead (Pb)
„ Mercury (Hg)
„ Cadmium (Cd)
„ Hexavalent Chromium (Cr (VI))
„ PolyBrominated Biphenyls (PBB’s)
„ PolyBrominated Diphenyl Ethers (PBDE’s)
The usage of the above substances in ZXG10 iBSC (V6.20.10) is
explained in the Table 4.

TABLE 4 – USAGE EXPLANATION OF THE HAZ ARDOUS SUBSTANCES IN ZXG10


IBSC (V6.20.10)

Hazardous substances
Names of Parts
Pb Hg Cd Cr(VI) PBB’s PBDE’s

System × 0 0 0 0 0
Cables and Assembly 0 0 0 0 0 0
Auxiliary Equipment × × × × × ×

Table Explanation:
0: The usage of the substance in all of the components is less
than the allowed values given by 2002/95/EC standard.
×: The usage of the substance in at least one of the components
is beyond the allowed values given by 2002/95/EC standard.

Confidential and Proprietary Information of ZTE CORPORATION v


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

The ZXG10 iBSC (V6.20.10) Base Station Controller


manufactured by ZTE CORPORATION meet the requirements of
EU 2002/95/EC; however, some assemblies are customized to
client specifications. Addition of specialized, customer-specified
materials or processes, which do not meet the requirements of
EU 2002/95 /EC, may negate RoHS compliance of the assembly.
To guarantee compliance of the assembly, the need for
compliant product must be communicated to ZTE CORPORATION
in written form.
This declaration is issued based on our current level of
knowledge. Since conditions of use are outside our control, ZTE
CORPORATION makes no warranties, express or implied, and
assumes no liability in connection with the use of this
information.

vi Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1

PS Basic Measurement
(BSC)

PS basic measurement (BSC) aims to make a statistic of the


performance related with packet switching service on BSC level.
This chapter describes the definition, usage and measurement
point of various counters.

Overview
PS basic measurement (BSC) consists of statistic of the number
of bytes received from data link and bytes sent to data link.
The measurement takes BSC as the statistics unit.

PS Basic Measurement (BSC)


Counter Index
Table 5 lists counters related to PS basic measurement (BSC).

TABLE 5 – PS BASIC MEASUREMENT (BSC) COUNTERS

Counter ID What It Counts


C900030001 Number of bytes received from data link
C900030002 Number of bytes sent to data link

C900030001
Definition Number of bytes received from data link

Confidential and Proprietary Information of ZTE CORPORATION 1


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Description This counter counts the total number of bytes received from all
BRCHs on FR sub-layer.
Usage This counter is used to find out the bytes received from BRCH
and to observe BSC load status.
Measurement FR accumulates all the bytes received from Gb interface BRCH.
Point

C900030002
Definition Number of bytes sent to data link
Description This counter counts the total number of bytes sent from all
BRCHs on FR sub-layer.
Usage This counter is used to find out the bytes sent from BRCH and to
observe BSC load status.
Measurement FR accumulates all the bytes sent from Gb interface BRCH.
Point

2 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2

PS Basic Measurement
(Cell)

PS basic measurement (Cell) collects formation of the PS service


(Cell) performance. This chapter gives detailed information
about the PS basic measurement (Cell).

Overview
PS basic measurement (Cell) involves the ordinary counters
used to measure the PS service performance and status, such as
the uplink (UL) /downlink (DL) TBF counter, the flow counter,
the UL/DL PACCH counter, the UL/DL RLC counter, the UL/DL
GPRS data counter, the UL/DL EGPRS data counter, and the PS
resource counter.
The measurement takes cell as the statistics unit.

PS Basic Measurement (Cell)


Counter Index
Table 6 lists counters related to PS basic measurement (Cell).

TABLE 6 - PS BASIC MEASUREMENT (CELL) COUNTERS

Counter ID What It Counts


Number of GPRS DL TBF establishment success on
C900040001
PACCH
Number of GPRS DL TBF release due to N3105
C900040002
overflow
Number of GPRS DL TBF release due to other
C900040003
reasons
C900040004 Number of GPRS DL TBF forcing release by control

Confidential and Proprietary Information of ZTE CORPORATION 3


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Counter ID What It Counts


plane
Number of GPRS DL TBF release due to instance
C900040005
suspension
Number of GPRS DL TBF release due to inner
C900040006
abnormal
C900040007 Number of GPRS DL signaling TBF establishment
C900040008 Number of GPRS DL data TBF establishment
Number of EGPRS DL TBF establishment success on
C900040009
PACCH
Number of EGPRS DL TBF release due to N3105
C900040010
overflow
Number of EGPRS DL TBF release due to other
C900040011
reasons
Number of EGPRS DL TBF forcing release by control
C900040012
plane
Number of EGPRS DL TBF release due to instance
C900040013
suspension
Number of EGPRS DL TBF release due to inner
C900040014
abnormal
C900040015 Number of EGPRS DL signaling TBF establishment
C900040016 Number of EGPRS DL data TBF establishment
Average number of GPRS DL TBF simultaneous
C900040017
establishment
Average number of EGPRS DL TBF simultaneous
C900040018
establishment
Number of GPRS UL data TBF establishment success
C900040019
on PACCH
Number of GPRS UL TBF release due to N3101
C900040020
overflow
Number of GPRS UL TBF release due to N3103
C900040021
overflow
Number of GPRS UL TBF forcing release by control
C900040022
plane
Number of GPRS UL TBF release due to instance
C900040023
suspension
Number of GPRS UL TBF release due to inner
C900040024
abnormal
C900040025 Number of GPRS UL signaling TBF establishment
C900040026 Number of GPRS UL data TBF establishment
Number of EGPRS UL TBF establishment success on
C900040027
PACCH
Number of EGPRS UL TBF release due to N3101
C900040028
overflow

4 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Counter ID What It Counts


Number of EGPRS UL TBF release due to N3103
C900040029
overflow
Number of EGPRS UL TBF forcing release by control
C900040030
plane
Number of EGPRS UL TBF release due to instance
C900040031
suspension
Number of EGPRS UL TBF release due to inner
C900040032
abnormal
C900040033 Number of EGPRS UL signaling TBF establishment
C900040034 Number of EGPRS UL data TBF establishment
Average number of GPRS UL TBF simultaneous
C900040035
establishment
Average number of EGPRS UL TBF simultaneous
C900040036
establishment
Number of GPRS UL signaling TBF release due to
C900040037
N3101 overflow
Number of GPRS UL signaling TBF release due to
C900040038
N3103 overflow
Number of GPRS UL signaling TBF forcing release by
C900040039
control plane
Number of GPRS UL signaling TBF release due to
C900040040
instance suspension
Number of GPRS UL signaling TBF release due to
C900040041
inner abnormal
Number of EGPRS UL signaling TBF release due to
C900040042
N3101 overflow
Number of EGPRS UL signaling TBF release due to
C900040043
N3103 overflow
Number of EGPRS UL signaling TBF forcing release
C900040044
by control plane
Number of EGPRS UL signaling TBF release due to
C900040045
instance suspension
Number of EGPRS UL signaling TBF release due to
C900040046
inner abnormal
C900040047 Number of EGPRS DL LLC frames
Number of discarded EGPRS DL LLC frames due to
C900040048
buffer overflow
Number of discarded EGPRS DL LLC frames due to
C900040049
life time expiration
Number of discarded EGPRS DL LLC frames due to
C900040050
other reasons
C900040051 Number of DL signaling LLC frames
Number of discarded EGPRS DL signaling LLC
C900040052
frames due to buffer overflow

Confidential and Proprietary Information of ZTE CORPORATION 5


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Counter ID What It Counts


Number of discarded EGPRS DL signaling LLC
C900040053
frames due to life time expiration
Number of discarded EGPRS DL signaling LLC
C900040054
frames due to other reasons
Number of data blocks transmitted according to
C900040055
given Abis bandwidth
Bytes of effective upper layer protocol data sent on
C900040056
DL PDCH
Bytes of effective upper layer protocol data received
C900040057
on UL PDCH
C900040058 Bytes of LLC frame on GPRS UL data TBF
C900040059 Duration of GPRS UL data TBF
C900040060 Bytes of LLC frame on GPRS DL data TBF
C900040061 Duration of GPRS DL data TBF
Number of effective data blocks received on GPRS
C900040062
UL TBF
C900040063 Number of NACK blocks received on GPRS UL TBF
Number of effective data blocks sent on GPRS DL
C900040064
TBF
C900040065 Number of NACK blocks sent on GPRS DL TBF
C900040066 Bytes of LLC frame on EGPRS UL data TBF
C900040067 Duration of EGPRS UL data TBF
C900040068 Bytes of LLC frame on EGPRS DL data TBF
C900040069 Duration of EGPRS DL data TBF
Number of effective data blocks received on EGPRS
C900040070
UL TBF
C900040071 Number of NACK blocks received on EGPRS UL TBF
Number of effective data blocks sent on EGPRS DL
C900040072
TBF
C900040073 Number of NACK blocks sent on EGPRS DL TBF
C900040074 Number of GPRS DL LLC frames
Number of discarded GPRS DL LLC frames due to
C900040075
buffer overflow
Number of discarded GPRS DL LLC frames due to
C900040076
life time expiration
Number of discarded GPRS DL LLC frames due to
C900040077
other reasons
C900040078 Number of DL dummy control blocks on PACCH
C900040079 Number of UL dummy control blocks on PACCH
Number of DL RLC blocks on PACCH(excluding
C900040080
dummy block)

6 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Counter ID What It Counts


C900040081 Number of DL RLC pending blocks in CS1 on PDTCH
C900040082 Number of DL RLC pending blocks in CS2 on PDTCH
C900040083 Number of DL RLC pending blocks in CS3 on PDTCH
C900040084 Number of DL RLC pending blocks in CS4 on PDTCH
C900040085 Number of DL RLC NACK blocks in CS1 on PDTCH
C900040086 Number of DL RLC NACK blocks in CS2 on PDTCH
C900040087 Number of DL RLC NACK blocks in CS3 on PDTCH
C900040088 Number of DL RLC NACK blocks in CS4 on PDTCH
C900040089 Number of DL RLC new blocks in CS1 on PDTCH
C900040090 Number of DL RLC new blocks in CS2 on PDTCH
C900040091 Number of DL RLC new blocks in CS3 on PDTCH
C900040092 Number of DL RLC new blocks in CS4 on PDTCH
Number of UL RLC blocks excluding dummy blocks
C900040093
on PACCH
C900040094 Number of UL RLC pending blocks in CS1 on PDTCH
C900040095 Number of UL RLC pending blocks in CS2 on PDTCH
C900040096 Number of UL RLC pending blocks in CS3 on PDTCH
C900040097 Number of UL RLC pending blocks in CS4 on PDTCH
C900040098 Number of UL RLC NACK blocks in CS1 on PDTCH
C900040099 Number of UL RLC NACK blocks in CS2 on PDTCH
C900040100 Number of UL RLC NACK blocks in CS3 on PDTCH
C900040101 Number of UL RLC NACK blocks in CS4 on PDTCH
C900040102 Number of UL RLC new blocks in CS1 on PDTCH
C900040103 Number of UL RLC new blocks in CS2 on PDTCH
C900040104 Number of UL RLC new blocks in CS3 on PDTCH
C900040105 Number of UL RLC new blocks in CS4 on PDTCH
C900040106 Number of UL data blocks received on PDTCH
C900040107 Number of DL data blocks sent on PDTCH
C900040108 Number of GPRS DL TBF establishment requests
Number of GPRS DL TBF establishment failure due
C900040109
to database allocation failure
Number of GPRS DL TBF resource reallocation
C900040110
requests due to UL TBF establishment
Number of GPRS DL TBF resource reallocation
C900040111
failure due to UL TBF establishment
Number of GPRS DL TBF resource reallocation
C900040112
requests due to LLC transmission
Number of GPRS DL TBF resource reallocation
C900040113
failure due to LLC transmission

Confidential and Proprietary Information of ZTE CORPORATION 7


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Counter ID What It Counts


C900040114 Number of EGPRS DL TBF establishment requests
Number of EGPRS DL TBF establishment failure due
C900040115
to database allocation failure
Number of EGPRS DL TBF resource reallocation
C900040116
requests due to UL TBF establishment
Number of EGPRS DL TBF resource reallocation
C900040117
failure due to UL TBF establishment
Number of EGPRS DL TBF resource reallocation
C900040118
requests due to LLC transmission
Number of EGPRS DL TBF resource reallocation
C900040119
failure due to LLC transmission
C900040120 Number of GPRS UL TBF establishment requests
Number of GPRS UL TBF establishment failure due
C900040121
to database allocation failure
Number of GPRS UL TBF resource reallocation
C900040122
requests due to DL TBF establishment
Number of GPRS UL TBF resource reallocation
C900040123
failure due to DL TBF establishment
Number of GPRS UL TBF resource reallocation
C900040124
requests due to LLC transmission
Number of GPRS UL TBF resource reallocation
C900040125
failure due to LLC transmission
Number of GPRS UL TBF resource reallocation
C900040126
requests for resource request
Number of GPRS UL TBF resource reallocation
C900040127 failure due to database allocation failure for
resource request
C900040128 Number of EGPRS UL TBF establishment requests
Number of EGPRS UL TBF establishment failure due
C900040129
to database allocation failure
Number of EGPRS UL TBF resource reallocation
C900040130
requests due to DL TBF establishment
Number of EGPRS UL TBF resource reallocation
C900040131
failure due to DL TBF establishment
Number of EGPRS UL TBF resource reallocation
C900040132
requests due to LLC transmission
Number of EGPRS UL TBF resource reallocation
C900040133
failure due to LLC transmission
Number of EGPRS UL TBF resource reallocation
C900040134
requests for resource request
Number of EGPRS UL TBF resource reallocation
C900040135
failure due to database allocation failure
C900040136 Number of available PDCH
C900040137 Number of forcing conversation dynamic from PDCH

8 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Counter ID What It Counts


to TCH by BSC
C900040138 Number of PDCH used by TBF in each cell
C900040139 Maximum number of used PDCH
C900040140 Average number of used PDCH
Number of GPRS DL TBF establishment requests
C900040141
before T3192 expiration
Number of GPRS DL TBF establishment using
C900040142
existing DL TBF resource
Number of GPRS DL TBF establishment requests on
C900040143
PACCH
Number of GPRS DL TBF establishment requests on
C900040144
CCCH/PCCCH
Number of EGPRS DL TBF establishment requests
C900040145
before T3192 expiration
Number of EGPRS DL TBF establishment using
C900040146
existing DL TBF resource
Number of EGPRS DL TBF establishment requests
C900040147
on PACCH
Number of EGPRS DL TBF establishment requests
C900040148
on CCCH/PCCCH
Number of GPRS DL signaling TBF release due to
C900040149
N3105 overflow
Number of GPRS DL signaling TBF release due to
C900040150
other reasons
Number of GPRS DL signaling TBF forcing release by
C900040151
control plane
Number of GPRS DL signaling TBF release due to
C900040152
instance suspension
Number of GPRS DL signaling TBF release due to
C900040153
inner abnormal
Number of EGPRS DL signaling TBF release due to
C900040154
N3105 overflow
Number of EGPRS DL signaling TBF release due to
C900040155
other reasons
Number of EGPRS DL signaling TBF forcing release
C900040156
by control plane
Number of EGPRS DL signaling TBF release due to
C900040157
instance suspension
Number of EGPRS DL signaling TBF release due to
C900040158
inner abnormal
Number of GPRS UL TBF establishments in release
C900040159
state
Number of GPRS UL TBF establishment with existing
C900040160
UL resource

Confidential and Proprietary Information of ZTE CORPORATION 9


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Counter ID What It Counts


Number of GPRS UL TBF establishment requests on
C900040161
PACCH
Number of EGPRS UL data TBF establishments on
C900040162
PACCH
Number of EGPRS UL TBF establishments in release
C900040163
state
Number of EGPRS UL TBF establishment with
C900040164
existing UL resource
Number of EGPRS UL TBF establishment requests
C900040165
on PACCH
Number of EGPRS UL TBF establishment requests
C900040166
on CCCH/PCCCH
Number of dynamic PDCH preemption for CS
C900040167
service
Number of GPRS UL TBF establishment requests on
C900040168
CCCH/PCCCH
Number of GPRS DL TBF establishment requests on
C900040169
PACCH
Number of EGPRS DL TBF establishment requests
C900040170
on PACCH
Number of GPRS UL TBF establishment requests on
C900040171
PACCH
Number of DL RLC pending blocks in MCS1 on
C900040172
PDTCH
Number of DL RLC pending blocks in MCS2 on
C900040173
PDTCH
Number of DL RLC pending blocks in MCS3 on
C900040174
PDTCH
Number of DL RLC pending blocks in MCS4 on
C900040175
PDTCH
Number of DL RLC pending blocks in MCS5 on
C900040176
PDTCH
Number of DL RLC pending blocks in MCS6 on
C900040177
PDTCH
Number of DL RLC pending blocks in MCS7 on
C900040178
PDTCH
Number of DL RLC pending blocks in MCS8 on
C900040179
PDTCH
Number of DL RLC pending blocks in MCS9 on
C900040180
PDTCH
C900040181 Number of DL RLC NACK blocks in MCS1 on PDTCH
C900040182 Number of DL RLC NACK blocks in MCS2 on PDTCH
C900040183 Number of DL RLC NACK blocks in MCS3 on PDTCH
C900040184 Number of DL RLC NACK blocks in MCS4 on PDTCH

10 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Counter ID What It Counts


C900040185 Number of DL RLC NACK blocks in MCS5 on PDTCH
C900040186 Number of DL RLC NACK blocks in MCS6 on PDTCH
C900040187 Number of DL RLC NACK blocks in MCS7 on PDTCH
C900040188 Number of DL RLC NACK blocks in MCS8 on PDTCH
C900040189 Number of DL RLC NACK blocks in MCS9 on PDTCH
C900040190 Number of DL RLC new blocks in MCS1 on PDTCH
C900040191 Number of DL RLC new blocks in MCS2 on PDTCH
C900040192 Number of DL RLC new blocks in MCS3 on PDTCH
C900040193 Number of DL RLC new blocks in MCS4 on PDTCH
C900040194 Number of DL RLC new blocks in MCS5 on PDTCH
C900040195 Number of DL RLC new blocks in MCS6 on PDTCH
C900040196 Number of DL RLC new blocks in MCS7 on PDTCH
C900040197 Number of DL RLC new blocks in MCS8 on PDTCH
C900040198 Number of DL RLC new blocks in MCS9 on PDTCH
Number of UL RLC pending blocks in MCS1 on
C900040199
PDTCH
Number of UL RLC pending blocks in MCS2 on
C900040200
PDTCH
Number of UL RLC pending blocks in MCS3 on
C900040201
PDTCH
Number of UL RLC pending blocks in MCS4 on
C900040202
PDTCH
Number of UL RLC pending blocks in MCS5 on
C900040203
PDTCH
Number of UL RLC pending blocks in MCS6 on
C900040204
PDTCH
Number of UL RLC pending blocks in MCS7 on
C900040205
PDTCH
Number of UL RLC pending blocks in MCS8 on
C900040206
PDTCH
Number of UL RLC pending blocks in MCS9 on
C900040207
PDTCH
C900040208 Number of UL RLC NACK blocks in MCS1 on PDTCH
C900040209 Number of UL RLC NACK blocks in MCS2 on PDTCH
C900040210 Number of UL RLC NACK blocks in MCS3 on PDTCH
C900040211 Number of UL RLC NACK blocks in MCS4 on PDTCH
C900040212 Number of UL RLC NACK blocks in MCS5 on PDTCH
C900040213 Number of UL RLC NACK blocks in MCS6 on PDTCH
C900040214 Number of UL RLC NACK blocks in MCS7 on PDTCH
C900040215 Number of UL RLC NACK blocks in MCS8 on PDTCH

Confidential and Proprietary Information of ZTE CORPORATION 11


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Counter ID What It Counts


C900040216 Number of UL RLC NACK blocks in MCS9 on PDTCH
C900040217 Number of UL RLC new blocks in MCS1 on PDTCH
C900040218 Number of UL RLC new blocks in MCS2 on PDTCH
C900040219 Number of UL RLC new blocks in MCS3 on PDTCH
C900040220 Number of UL RLC new blocks in MCS4 on PDTCH
C900040221 Number of UL RLC new blocks in MCS5 on PDTCH
C900040222 Number of UL RLC new blocks in MCS6 on PDTCH
C900040223 Number of UL RLC new blocks in MCS7 on PDTCH
C900040224 Number of UL RLC new blocks in MCS8 on PDTCH
C900040225 Number of UL RLC new blocks in MCS9 on PDTCH

C900040001
Definition Number of GPRS DL TBF establishment success on PACCH
Description This counter counts the number of successful DL GPRS TBF
establishments on the UL/DL GPRS TBF PACCH.
Measurement When the DL GPRS TBF is established on the UL/DL GPRS TBF
Point PACCH and a message indicating assignment success is sent,
this counter increments. The measurement points are A as
shown in Figure 1 and Figure 2, and A2 as shown in Figure 3.

FIGURE 1 – MEASUREMENT POINT OF NUMBER OF REQUESTS FOR


ESTABLISHING GPRS DOWNLINK DAT A TBF BEFORE T3192 OVERTIME

MS BSC SGSN
LLC Frame
RLC Block
LLC Frame
RLC Block
RLC Block(FBI=1)
Start T3193

LLC Frame
Packet Downlink Assignment
A

12 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

FIGURE 2 – MEASUREMENT POINT OF NUMBER OF ESTABLISHED GPRS


DOWNLINK DATA TBF USING EXISTING RESOURCES

MS BSC SGSN

RLC Block
RLC Block
LLC Frame
Packet Downlink Assignment
(Packet Timeslot Reconfigure)
A
RLC Block

FIGURE 3 – MEASUREMENT POINT OF NUMBER OF REQUESTS FOR


ESTABLISHING GPRS DOWNLINK DAT A TBF ON UPLINK GPRS TBF PACCH

MS BSC user BSC control SGSN


plane plane
RLC Block
RLC Block
LLC Frame (no record downlink resource)

A1
Downlink Assign Request
Packet Downlink Assignment Resource Assignment
(Packet Timeslot Reconfigure)

A2

C900040002
Definition Number of GPRS DL TBF release due to N3105 overflow
Description During the DL TBF transmission, the DL block RRBP bit is set to
ask MS to respond with a Packet Downlink Ack/Nack message.
If the specified block of BSC fails to receive response from MS,
then the N3105 counter increments; otherwise, it has a clear. If
no response comes from the MS, then the RRBP bit is set again
to ask MS to respond with a Packet Downlink Ack/Nack
message; if the N3105 counter reaches its maximum value, it is
considered that the radio transmission fails and the DL TBF is
released abnormally.
Measurement When the N3105 counter value exceeds N3105Max, this counter
Point increments. The measurement point is A1, as shown in Figure 4.

Confidential and Proprietary Information of ZTE CORPORATION 13


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 4 – MEASUREMENT POINT OF NUMBER OF GPRS DL TBF RELEASE


DUE TO N3105 OVERFLOW

BSC user
MS
plane

RLC/MAC Block(RRBP)

DOWNLINK ACK

N3105=0
DOWNLINK ACK LOSS

N3105 > N3105Max

A1

C900040003
Definition Number of GPRS DL TBF release due to other reasons
Description When BSC is transmitting the last DL TBF RLC block, set FBI to 1,
set RRBP to ask the MS to respond with a Packet Downlink
Ack/Nack message, and at the same time, activate T3191. If the
specified block receives the MS response, then T3191 will stop
and the DL transmission ends normally. If T3191 overflows, then
it is considered that the radio transmission fails and the DL TBF
is released abnormally.
Measurement The measurement point is A1, as shown in Figure 5.
Point
FIGURE 5 – MEASUREMENT POINT OF NUMBER OF GPRS DL TBF RELEASE
DUE TO OTHER REASONS

MS BSC

RLC Block

Start T3191
DOWNLINK ACK

Normal release

T3191 Timeout
A1

14 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

C900040004
Definition Number of GPRS DL TBF forcing release by control plane

Description When the user plane is transmitting the DL TBF, if a release


request comes from the control plane, then the DL TBF will stop
and be released abnormally.
Measurement When the user plane receives the release request from the
Point control plane, this counter increments. The measurement point
is A, as shown in Figure 6.

FIGURE 6 – MEASUREMENT POINT OF NUMBER OF GPRS DL TBF FORCING


RELEASE BY CONTROL PLANE

C900040005
Definition Number of GPRS DL TBF release due to instance suspension
Description When the user plane is transmitting the DL TBF, at least one
block must be transmitted in every 5 seconds. After a DL TBF
block is transmitted, BSC will start or restart a 5-second DL
block assigning timer. If the timer expires, it is considered that
the user plane has an instance suspension and the DL TBF is
released abnormally.
Measurement When the DL block assigning timer expires, this counter
Point increments. The measurement point is A, as shown in Figure 7.

Confidential and Proprietary Information of ZTE CORPORATION 15


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 7 - MEASUREMENT POINT OF NUMBER OF GPRS DL TBF RELEASE


DUE TO INSTANCE SUSPENSION

C900040006
Definition Number of GPRS DL TBF release due to inner abnormal
Description When the user plane is transmitting the DL TBF, if the message
fails to be sent at the radio interface, the RLC instance fails to be
created, or the resource reassignment fails, the DL TBF will be
released abnormally.
Measurement During the DL TBF transmission, if the message fails to be sent
Point at the radio interface, the RLC instance fails to be created, or the
resource reassignment fails, this counter increments.

C900040007
Definition Number of GPRS DL signaling TBF establishment
Description According to the type of the transmitted UL data, TBF has two
categories: signaling TBF and data TBF.
This counter counts the number of establishments of GPRS DL
TBF for UL signaling transmission. The UL signaling involves
some UL processes such as ATTACH, PDP activation, and routing
area update.
Measurement When the DL TBF is created successfully and the TBF type is
Point GPRS signaling TBF, the counter increments. The measurement
point is similar to those of C900040001 and C901000014.

16 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

C900040008
Definition Number of GPRS DL data TBF establishment
Description According to the type of the transmitted UL data, TBF has two
categories: signaling TBF and data TBF.
This counter counts the number of establishments of GPRS DL
TBF for user data (no-UL-signaling) transmission.
Measurement When the DL TBF is created successfully and the TBF type is
Point GPRS data TBF, the counter increments. The measurement point
is similar to those of C900040001 and C901000014.

C900040009
Definition Number of EGPRS DL TBF establishment success on PACCH
Description This counter counts the number of successful DL EGPRS TBF
establishments on the UL/DL EGPRS TBF PACCH.
Measurement When the DL EGPRS TBF is established on the UL/DL EGPRS TBF
Point PACCH and a message indicating assignment success is sent,
this counter increments. The measurement points are A as
shown in Figure 1 and Figure 2, and A2 as shown in Figure 3.

C900040010
Definition Number of EGPRS DL TBF release due to N3105 overflow
Description „ During the DL TBF transmission, the DL block RRBP bit is set
to ask the MS to respond with a Packet Downlink Ack/Nack
message.
If the specified block of BSC does not receive the MS response,
then the N3105 counter increments; if it does, then it has a
clear; if no response comes from the MS, then the RRBP bit is
set again to ask the MS to respond with a Packet Downlink
Ack/Nack message; if the N3105 counter reaches its maximum
value, it is considered that the radio transmission fails and the
DL TBF is released abnormally.
Measurement When the N3105 counter value exceeds N3105Max, this counter
Point increments. The measurement point is A1, as shown in Figure 8.

Confidential and Proprietary Information of ZTE CORPORATION 17


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 8 – MEASUREMENT POINT OF NUMBER OF EGPRS DL TBF RELEASE


DUE TO N3105 OVERFLOW

C900040011
Definition Number of EGPRS DL TBF release due to other reasons
Description When BSC is transmitting the last DL TBF RLC block, set FBI to 1,
set RRBP to ask the MS to respond with a Packet Downlink
Ack/Nack message, and at the same time, activate T3191. If the
specified block receives the MS response, then T3191 will stop
and the DL transmission ends normally. If T3191 overflows, then
it is considered that the radio transmission fails and the DL TBF
is released abnormally.
Measurement The measurement point is A1, as shown in Figure 9.
Point
FIGURE 9 – MEASUREMENT POINT OF NUMBER OF EGPRS DL TBF RELEASE
DUE TO OTHER REASONS

MS BSC

RLC Block

Start T3191
DOWNLINK ACK

Normal release

T3191 Timeout
A1

Unit Times

18 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

C900040012
Definition Number of EGPRS DL TBF forcing release by control plane
Description When the user plane is transmitting the DL TBF, if a release
request comes from the control plane, then the DL TBF will stop
and be released abnormally.
Measurement When the user plane receives the release request from the
Point control plane, this counter increments. The measurement point
is A, as shown in Figure 10.

FIGURE 10 – MEASUREMENT POINT OF NUMBER OF EGPRS DL TBF FORCING


RELEASE BY CONTROL PLANE

Unit Times

C900040013
Definition Number of EGPRS DL TBF release due to instance suspension
Description When the user plane is transmitting the DL TBF, at least one
block must be transmitted in every 5 seconds. After a DL TBF
block is transmitted, BSC will start or restart a 5-second DL
block assigning timer. If the timer expires, it is considered that
the user plane has an instance suspension and the DL TBF is
released abnormally.
Measurement When the DL block assigning timer expires, this counter
Point increments. The measurement point is A1, as shown in Figure 11.

Confidential and Proprietary Information of ZTE CORPORATION 19


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 11 - MEASUREMENT POINT OF NUMBER OF EGPRS DL TBF RELEASE


DUE TO INSTANCE SUSPENSION

Unit Times

C900040014
Definition Number of EGPRS DL TBF release due to inner abnormal
Description When the user plane is transmitting the DL TBF, if the message
fails to be sent at the radio interface, the RLC instance fails to be
created, or the resource reassignment fails, the DL TBF will be
released abnormally.
Measurement During the DL TBF transmission, if the message fails to be sent
Point at the radio interface, the RLC instance fails to be created, or the
resource reassignment fails, this counter increments.
Unit Times

C900040015
Definition Number of EGPRS DL signaling TBF establishment
Description According to the type of the transmitted UL data, TBF has two
categories: signaling TBF and data TBF.
This counter counts the number of establishments of EGPRS DL
TBF for UL signaling transmission. The UL signaling involves
some UL processes such as ATTACH, PDP activation, and routing
area update.
Measurement When the DL TBF is created successfully and the TBF type is
Point signaling TBF, the counter increments. The measurement point
is similar to those of C900040001 and C901000014.
Unit Times

20 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

C900040016
Definition Number of EGPRS DL data TBF establishment
Description According to the type of the transmitted UL data, TBF has two
categories: signaling TBF and data TBF.
This counter counts the number of establishments of EGPRS DL
TBF for user data (no-UL-signaling) transmission.
Measurement When the DL TBF is created successfully and the TBF type is
Point data TBF, the counter increments. The measurement point is
similar to those of C900040001 and C901000014.
Unit Times

C900040017
Definition Average number of GPRS DL TBF simultaneous establishment
Description This counter counts the average number of DL GPRS TBF
establishments in a cell.
Measurement The counter acquires the measurement value regularly. The
Point number of GPRS TBFs existing in the cell is considered the
average number.
Unit Times

C900040018
Definition Average number of EGPRS DL TBF simultaneous establishment
Description This counter counts the average number of DL EGPRS TBF
establishments in a cell.
Measurement The counter acquires the measurement value regularly. The
Point number of EGPRS TBFs existing in the cell is considered the
average number.
Unit Times

C900040019
Definition Number of GPRS UL data TBF establishment success on PACCH
Description When MS has a DL TBF and the TBF is being transmitted, if the
UL data need to be transmitted but there is no corresponding UL
TBF, then the Packet Downlink Ack message will carry the UL
TBF establishment request. Usually BSS will assign the resource
to MS, and then an UL TBF is established successfully.

Confidential and Proprietary Information of ZTE CORPORATION 21


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Usage The counter counts the number of successful GPRS UL TBF


establishments on PACCH
Measurement The measurement point is A, as shown in Figure 12.
Point
FIGURE 12 - MEASUREMENT POINT OF NUMBER OF GPRS UL DAT A TBF
ESTABLISHM ENT SUCCESS ON P ACCH

Unit Times

C900040020
Definition Number of GPRS UL TBF release due to N3101 overflow
Description After the UL TBF is established, MS will transmit data on the
BSS-assigned UL block. If the specified block of BSS fails to
receive RLC block from MS, N3101 increments. Otherwise,
N3101 will have a clear. When N3101 exceeds the maximum
value, BSS will release UL TBF.
Usage The counter counts the number of abnormal releases of GPRS UL
TBF due to N3101 overflow.
Measurement The measurement point is N3101 overflow, as A shown in Figure
Point 13.

FIGURE 13 - MEASUREMENT POINT OF NUMBER OF GPRS UL TBF RELEASE


DUE TO N3101 OVERFLOW

Unit Times

C900040021
Definition Number of GPRS UL TBF release due to N3103 overflow

22 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Description When BSS receives all UL RLC blocks, it will send MS a Packet
Uplink Ack message in which FAI and RRBP are set. MS will
report Packet Control Ack to the corresponding UL block. If
BSS fails to receive it, N3103 increments. When N3103 exceeds
the maximum value, BSS will release UL TBF.
Usage The counter counts the number of abnormal releases of GPRS UL
TBF due to N3103 overflow.
Measurement The measurement point is N3103 overflow, as A shown in Figure
Point 14.

FIGURE 14 - MEASUREMENT POINT OF NUMBER OF GPRS UL TBF RELEASE


DUE TO N3103 OVERFLOW

Unit Times

C900040022
Definition Number of GPRS UL TBF forcing release by control plane
Description When an UL TBF establishment is held, the control plane may
forcibly release this UL TBF.
Usage The counter counts the number of forced releases of GPRS UL
TBF due to release request from the control plane.
Measurement The measurement point is arrival of the release request, as A
Point shown in Figure 15.

FIGURE 15 - MEASUREMENT POINT OF NUMBER OF GPRS UL TBF FORCING


RELEASE BY CONTROL PLANE

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 23


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040023
Definition Number of GPRS UL TBF release due to instance suspension
Description BSS creates an instance for an UL TBF. If the instance is
suspended for some reason, then BSS should release this UL
TBF.
Usage The counter counts the number of abnormal releases of GPRS UL
TBF due to suspension of the instance.
Measurement The measurement point is that UPPB detects suspension of the
Point instance, as A shown in Figure 16.

FIGURE 16 - MEASUREMENT POINT OF NUMBER OF GPRS UL TBF RELEASE


DUE TO INSTANCE SUSPENSION

Unit Times

C900040024
Definition Number of GPRS UL TBF release due to inner abnormal
Description TBF is abnormally released due to UPPB internal error.
Usage The counter counts the number of abnormal releases of GPRS UL
TBF due to internal error.
Measurement The measurement point is abnormal UPPB suspension, as B
Point shown in Figure 16.
Unit Times

C900040025
Definition Number of GPRS UL signaling TBF establishment
Description For different purpose, MS may establish two types of TBF:
signaling TBF and data TBF.
Usage The counter counts the number of GPRS UL signaling TBF link
establishments.
Measurement The measurement point is that UPPB access type is signaling TBF.
Point For all 1-step accesses, their type is considered signaling TBF, as

24 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

A1 shown in Figure 17. For the 2-step accesses, the TBF type is
detected as SIGNAL_TBF, as A1 shown in Figure 18.

FIGURE 17 – UL TBF FLOW OF 1-STEP ACCESS

Confidential and Proprietary Information of ZTE CORPORATION 25


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 18 - UL TBF FLOW OF 2-STEP ACCESS

MS BSS

Channel Request/Packet Channel


Request

Immediate Assignment/Packet Uplink


Assignment

Packet Resource Request


A1
Packet Uplink
Assignment

Data Block (CV!=0)

Packet Uplink Ack (FAI=0)

Data Block (CV=0)

P_UPLINK_ACK (FAI=1)

P_CTRL_ACK

A2

Unit Times

C900040026
Definition Number of GPRS UL data TBF establishment
Description For different purpose, MS may establish two types of TBF:
signaling TBF and data TBF.
Usage The counter counts the number of GPRS UL data TBF link
establishments.
Measurement The measurement point is when UPPB access type is data TBF.
Point For example, the TBF type is detected as DATA_TBF, as A1
shown in Figure 18.
Unit Times

26 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

C900040027
Definition Number of EGPRS UL TBF establishment success on PACCH
Description When MS has a DL TBF and the TBF is being transmitted, if the
UL data need to be transmitted but there is no corresponding UL
TBF, then the Packet Downlink Ack message will carry the UL
TBF establishment request. Usually BSS will assign the resource
to MS, and then an UL TBF is established successfully.
Usage The counter counts the number of successful EGPRS UL TBF
establishments on PACCH
Measurement The measurement point is A, as shown in Figure 19.
Point
FIGURE 19 - MEASUREMENT POINT OF NUMBER OF EGPRS UL TBF
ESTABLISHM ENT SUCCESS ON P ACCH

Unit Times

C900040028
Definition Number of EGPRS UL TBF release due to N3101 overflow
Description After the UL TBF is established, MS will transmit data on the
BSS-assigned UL block. If the specified block of BSS fails to
receive RLC block from MS, N3101 increments. Otherwise,
N3101 will have a clear. When N3101 exceeds the maximum
value, BSS will release UL TBF.
Usage The counter counts the number of abnormal releases of EGPRS
UL TBF due to N3101 overflow.
Measurement The measurement point is when N3101 overflow.
Point

Unit Times

C900040029
Definition Number of EGPRS UL TBF release due to N3103 overflow
Description When BSS receives all UL RLC blocks, it will send MS a Packet
Uplink Ack message in which FAI and RRBP are set. MS will

Confidential and Proprietary Information of ZTE CORPORATION 27


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

report Packet Control Ack to the corresponding UL block. If


BSS fails to receive it, N3103 increments. When N3103 exceeds
the maximum value, BSS will release UL TBF.
Usage The counter counts the number of abnormal releases of EGPRS
UL TBF due to N3103 overflow.
Measurement The measurement point is when N3103 overflow.
Point
Unit
Times

C900040030
Definition Number of EGPRS UL TBF forcing release by control plane
Description When an UL TBF establishment is held, the control plane may
forcibly release this UL TBF.
Usage The counter counts the number of forced releases of EGPRS UL
TBF due to release request from the control plane.
Measurement The measurement point is arrival of the release request.
Point

Unit Times

C900040031
Definition Number of EGPRS UL TBF release due to instance suspension
Description BSS creates an instance for an UL TBF. If the instance is
suspended for some reason, then BSS should release this UL
TBF.
Usage The counter counts the number of abnormal releases of EGPRS
UL TBF due to suspension of the instance.
Measurement The measurement point is that UPPB detects suspension of the
Point instance.

Unit Times

C900040032
Definition Number of EGPRS UL TBF release due to inner abnormal
Description TBF is abnormally released due to UPPB internal error.
Usage The counter counts the number of abnormal releases of EGPRS
UL TBF due to internal error.

28 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Measurement The measurement point is abnormal UPPB suspension.


Point

Unit Times

C900040033
Definition Number of EGPRS UL signaling TBF establishment
Description For different purpose, MS may establish two types of TBF:
signaling TBF and data TBF.
Usage The counter counts the number of EGPRS UL signaling TBF link
establishments.
Measurement The measurement point is that UPPB access type is signaling TBF.
Point

Unit Times

C900040034
Definition Number of EGPRS UL data TBF establishment
Description For different purpose, MS may establish two types of TBF:
signaling TBF and data TBF.
Usage The counter counts the number of EGPRS UL data TBF link
establishments.
Measurement The measurement point is that UPPB access type is data TBF.
Point

Unit Times

C900040035
Definition Average number of GPRS UL TBF simultaneous establishment
Description There may be more than one TBF in the system during the
sampling period. Average number of uplink GPRS TBF
establishing simultaneously = Number of UL GPRS TBFs
established simultaneously in the sampling period / Times of
sampling
Usage This counter counts the average number of UL GPRS TBF
establishing simultaneously.
Measurement When UPPB receives the message informing UL GPRS TBF
Point establishment, the number of TBFs is refreshed and the times of
sampling accumulates.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 29


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040036
Definition Average number of EGPRS UL TBF simultaneous establishment
Description There may be more than one TBF in the system during the
sampling period. Average number of uplink EGPRS TBF
establishing simultaneously = Number of UL EGPRS TBFs
established simultaneously in the sampling period / Times of
sampling
Usage This counter counts the average number of UL EGPRS TBF
establishing simultaneously.
Measurement When UPPB receives the message informing UL EGPRS TBF
Point establishment, the number of TBFs is refreshed and the times of
sampling accumulates.
Unit Times

C900040037
Definition Number of GPRS UL signaling TBF release due to N3101 overflow
Description After the UL TBF is established, MS will transmit data on the
BSS-assigned UL block. If the specified block of BSS fails to
receive RLC block from MS, N3101 increments. Otherwise,
N3101 will have a clear. When N3101 exceeds the maximum
value, BSS will release UL TBF.
Usage The counter counts the number of abnormal releases of GPRS
signaling UL TBF due to N3101 overflow.
Measurement The measurement point is N3101 overflow.
Point

Unit Times

C900040038
Definition Number of GPRS UL signaling TBF release due to N3103 overflow
Description When BSS receives all UL RLC blocks, it will send MS a Packet
Uplink Ack message in which FAI and RRBP are set. MS will
report Packet Control Ack to the corresponding UL block. If
BSS fails to receive it, N3103 increments. When N3103 exceeds
the maximum value, BSS will release UL TBF.
Usage The counter counts the number of abnormal releases of GPRS
signaling UL TBF due to N3103 overflow.
Measurement The measurement point is N3103 overflow.
Point

30 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Unit Times

C900040039
Definition Number of GPRS UL signaling TBF forcing release by control
plane
Description When an UL TBF establishment is held, the control plane may
forcibly release this UL TBF.
Usage The counter counts the number of forced releases of GPRS
signaling UL TBF due to release request from the control plane.
Measurement The measurement point is arrival of the release request.
Point

Unit Times

C900040040
Definition Number of GPRS UL signaling TBF release due to instance
suspension
Description BSS creates an instance for an UL TBF. If the instance is
suspended for some reason, then BSS should release this UL
TBF.
Usage The counter counts the number of abnormal releases of GPRS
signaling UL TBF due to suspension of the instance.
Measurement The measurement point is that UPPB detects suspension of the
Point instance.
Unit Times

C900040041
Definition Number of GPRS UL signaling TBF release due to inner abnormal
Description TBF is abnormally released due to UPPB internal error.
Usage The counter counts the number of abnormal releases of GPRS
signaling UL TBF due to internal error.
Measurement The measurement point is abnormal UPPB suspension.
Point

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 31


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040042
Definition Number of EGPRS UL signaling TBF release due to N3101
overflow
Description After the UL TBF is established, MS will transmit data on the
BSS-assigned UL block. If the specified block of BSS fails to
receive RLC block from MS, N3101 increments. Otherwise,
N3101 will have a clear. When N3101 exceeds the maximum
value, BSS will release UL TBF.
Usage The counter counts the number of abnormal releases of EGPRS
signaling UL TBF due to N3101 overflow.
Measurement The measurement point is N3101 overflow.
Point

Unit Times

C900040043
Definition Number of EGPRS UL signaling TBF release due to N3103
overflow
Description When BSS receives all UL RLC blocks, it will send MS a Packet
Uplink Ack message in which FAI and RRBP are set. MS will
report Packet Control Ack to the corresponding UL block. If
BSS fails to receive it, N3103 increments. When N3103 exceeds
the maximum value, BSS will release UL TBF.
Usage The counter counts the number of abnormal releases of EGPRS
signaling UL TBF due to N3103 overflow.
Measurement The measurement point is N3103 overflow.
Point

Unit Times

C900040044
Definition Number of EGPRS UL signaling TBF forcing release by control
plane
Description When an UL TBF establishment is held, the control plane may
forcibly release this UL TBF.
Usage The counter counts the number of forced releases of EGPRS
signaling UL TBF due to release request from the control plane.
Measurement The measurement point is arrival of the release request.
Point

Unit Times

32 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

C900040045
Definition Number of EGPRS UL signaling TBF release due to instance
suspension
Description BSS creates an instance for an UL TBF. If the instance is
suspended for some reason, then BSS should release this UL
TBF.
Usage The counter counts the number of abnormal releases of EGPRS
signaling UL TBF due to suspension of the instance.
Measurement The measurement point is that UPPB detects suspension of the
Point instance.
Unit Times

C900040046
Definition Number of EGPRS UL signaling TBF release due to inner
abnormal
Description TBF is abnormally released due to UPPB internal error.
Usage The counter counts the number of abnormal releases of EGPRS
signaling UL TBF due to internal error.
Measurement The measurement point is abnormal UPPB suspension.
Point

Unit Times

C900040047
Definition Number of EGPRS DL LLC frames
Description The DL GIPB sends DL UnitData to UPPB through IP packets.
tQoSProfile Tbit in DL UnitData identifies whether data or
signaling is transmitted. UPPB applies to CMP to establish DL TBF
(radio access capacity to carry MS) and according to the CMP
request, establishes EGPRS/GPRS TBF.
Usage The counter counts the number of EGPRS DL LLC frames.
Measurement The measurement point is A, as shown in Figure 20.
Point

Confidential and Proprietary Information of ZTE CORPORATION 33


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 20 - MEASUREMENT POINT OF NUMBER OF EGPRS DL LLC FRAMES

Unit Times

C900040048
Definition Number of discarded EGPRS DL LLC frames due to buffer
overflow
Description The DL GIPB sends DL UnitData to UPPB through IP packets. If
UPPB fails to acquire buffer, then it will send the LLC Discard
message to SGSN.
Usage The counter counts the number of discarded EGPRS DL LLC
frames due to buffer overflow.
Measurement The measurement point is A, as shown in Figure 21.
Point
FIGURE 21 - MEASUREMENT POINT OF NUMBER OF DISCARDED EGPRS DL
LLC FRAMES DUE TO BUFFER OVERFLOW

Unit Times

C900040049
Definition Number of discarded EGPRS DL LLC frames due to life time
expiration
Description The DL GIPB sends DL UnitData to UPPB through IP packets. If
UPPB fails to send them before the LLC frame life time expires,
then it will send the LLC Discard message to SGSN.
Usage

34 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

The counter counts the number of discarded EGPRS DL LLC


frames due to life time expiration.
Measurement The measurement point is A, as shown in Figure 22.
Point
FIGURE 22 - MEASUREMENT POINT OF NUMBER OF DISCARDED EGPRS DL
LLC FRAMES DUE TO LIFE TIME EXPIRATION

Unit Times

C900040050
Definition Number of discarded EGPRS DL LLC frames due to other reasons
Description The DL GIPB sends DL UnitData to UPPB through IP packets. If
UPPB fails to send them for reasons other than the above two in
C900040048 and C900040049, then it will send the LLC
Discard message to SGSN.
Usage The counter counts the number of discarded EGPRS DL LLC
frames due to other reasons than the above two in C900040048
and C900040049.
Measurement The measurement point is A, as shown in Figure 23.
Point
FIGURE 23 - MEASUREMENT POINT OF NUMBER OF DISCARDED EGPRS DL
LLC FRAMES DUE TO OTHER REASONS

Unit Times

C900040051
Definition Number of DL signaling LLC frames

Confidential and Proprietary Information of ZTE CORPORATION 35


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Description The DL GIPB sends DL UnitData to UPPB through IP packets.


tQoSProfile Tbit in DL UnitData identifies whether data or
signaling is transmitted. UPPB applies to the control plane to
establish DL TBF (radio access capacity to carry MS) and
according to the request of the control plane, establishes
EGPRS/GPRS TBF.
Usage The counter counts the number of DL signaling LLC frames.
Measurement The measurement point is A, as shown in Figure 24.
Point
FIGURE 24 - MEASUREMENT POINT OF NUMBER OF DL SIGNALING LLC
FRAMES

Unit Times

C900040052
Definition Number of discarded EGPRS DL signaling LLC frames due to
buffer overflow
Description The DL GIPB sends DL UnitData to UPPB through IP packets. If
UPPB fails to acquire buffer, then it will send the LLC Discard
message to SGSN.
Usage The counter counts the number of discarded EGPRS DL signaling
LLC frames due to buffer overflow.
Measurement The measurement point is A, as shown in Figure 25.
Point

FIGURE 25 - MEASUREMENT POINT OF NUMBER OF DISCARDED EGPRS DL


SIGNALING LLC FRAMES DUE TO BUFFER OVERFLOW

36 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Unit Times

C900040053
Definition Number of discarded EGPRS DL signaling LLC frames due to life
time expiration
Description The DL GIPB sends DL UnitData to UPPB through IP packets. If
UPPB fails to send them before the LLC frame life time expires,
then it will send the LLC Discard message to SGSN.
Usage The counter counts the number of discarded EGPRS DL signaling
LLC frames due to life time expiration.
Measurement The measurement point is A, as shown in Figure 26.
Point
FIGURE 26 - MEASUREMENT POINT OF NUMBER OF DISCARDED EGPRS DL
SIGNALING LLC FRAMES DUE TO LIFE TIME EXPIRATION

Unit Times

C900040054
Definition Number of discarded EGPRS DL signaling LLC frames due to
other reasons
Description The DL GIPB sends DL UnitData to UPPB through IP packets. If
UPPB fails to send them for reasons other than the above two in
C900040052 and C900040053, then it will send the LLC
Discard message to SGSN.
Usage The counter counts the number of discarded EGPRS DL signaling
LLC frames due to other reasons than the above two in
C900040052 and C900040053.
Measurement The measurement point is A, as shown in Figure 27.
Point

Confidential and Proprietary Information of ZTE CORPORATION 37


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 27 - MEASUREMENT POINT OF NUMBER OF DISCARDED EGPRS DL


SIGNALING LLC FRAMES DUE TO OTHER REASONS

Unit Times

C900040055
Definition Number of data blocks transmitted according to given Abis
bandwidth
Description Because the bandwidth carrying the Abis-interface (TS) timeslot
is limited, PS may need 1 or more Abis TSs for specific RLC
coding modes. If the number of Abis TSs bond to the channel is
definite, the RLC coding mode is also definite for the channel.
Usage The counter counts the number of data blocks transmitted
according to given Abis bandwidth.
Measurement During the DL PCU frame transmission, if the number of Abis
Point TSs required by the coding mode equals that of Abis TSs bond to
the channel, the counter increments.
Unit Times

C900040056
Definition Bytes of effective upper layer protocol data sent on DL PDCH
Description UPPB divides the DL LLC frame into RLC blocks and sends them
to MS. After correctly receiving those RLC blocks, MS will
recompose the LLC frame. UPPB acquires the information about
MS reception by setting RRBP to let MS report the Packet
Downlink Ack / EGPRS Packet Downlink Ack message.
Usage The counter counts the bytes of effective upper layer protocol
data sent on DL PDCH.
Measurement The measurement point is A, as shown in Figure 28.
Point

38 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

FIGURE 28 - MEASUREMENT POINT OF TOTAL BYTES OF EFFECTIVE UPPER


LAYER PROTOCOL DAT A SENT ON DL PDCH

MS BSS
downlink RLC blocks & not setting RRBP

downlink RLC blocks & setting RRBP

Packet Downlink Ack/Egprs Packet


Downlink Ack

A
Unit Byte

C900040057
Definition Bytes of effective upper layer protocol data received on UL PDCH
Description After receiving the RLC blocks reported by MS, UPPB composes
them into the LLC frame and sends it to SGSN. At same time,
UPPB sends the Packet Uplink Ack message to MS by a certain
rule.
Usage The counter counts the bytes of effective upper layer protocol
data received on UL PDCH.
Measurement The measurement point is A, as shown in Figure 29.
Point
FIGURE 29 - MEASUREMENT POINT OF TOTAL BYTES OF EFFECTIVE UPPER
LAYER PROTOCOL DAT A RECEIVED ON UL PDCH

Unit Byte

C900040058
Definition Bytes of LLC frame on GPRS UL data TBF
Description After receiving the RLC blocks reported by MS, UPPB composes
them into the LLC frame and sends it to SGSN. At same time,
UPPB sends the Packet Uplink Ack message to MS by a certain
rule.
Usage The counter counts the bytes carried by GPRS UL data TBF LLC
frame.

Confidential and Proprietary Information of ZTE CORPORATION 39


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Measurement The measurement point is A, as shown in Figure 30.


Point

FIGURE 30 - MEASUREMENT POINT OF BYTES OF LLC FRAME ON GPRS UL


DATA TBF

Unit Byte

C900040059
Definition Duration of GPRS UL data TBF
Description The duration starts when BSS receives the UL access from MS
and ends when BSS receives the data block (CV=0) and all the
other blocks have arrived.
Usage The counter counts the duration of GPRS UL data TBF.
Measurement The duration lasts from UPPB’s reception of UL TBF
Point establishment request to transmission of Packet Uplink Ack
with FAI set. The measurement point is A, as shown in Figure 31.

FIGURE 31 - MEASUREMENT POINT OF DURATION OF GPRS UL DATA TBF

Unit Ms

C900040060
Definition Bytes of LLC frame on GPRS DL data TBF
Description UPPB divides the DL LLC frame into RLC blocks and sends them
to MS. Besides. UPPB sets RRBP by a certain rule. Then MS

40 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

reports Packet Downlink Ack/EGPRS Packet Downlink Ack in


the specific UL block.
Usage The counter counts the bytes of LLC frame on GPRS DL data TBF.
Measurement The measurement point is A, as shown in Figure 32.
Point

FIGURE 32 - MEASUREMENT POINT OF BYTES OF LLC FRAME ON GPRS DL


DATA TBF

Unit Byte

C900040061
Definition Duration of GPRS DL data TBF
Description The duration lasts from BSS’s reception of the UL TBF
establishment request to its reception of Packet Downlink
Ack/EGPRS Packet Downlink Ack (Packet Control Ack in non-
reply mode) with FAI=1 sent from MS.
Usage The counter counts the duration of GPRS DL data TBF.
Measurement The measurement point is A, as shown in Figure 33.
Point
FIGURE 33 - MEASUREMENT POINT OF DURATION OF GPRS DL DATA TBF

Unit Ms

Confidential and Proprietary Information of ZTE CORPORATION 41


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040062
Definition Number of effective data blocks received on GPRS UL TBF
Description During the TBF transmission, MS divides the UL LLC frame into
RLC blocks and sends them to BSS. Only when BSS receives all
these RLC blocks can it recompose the LLC frame.
Usage The counter counts the number of effective data blocks received
on GPRS UL TBF
Measurement The measurement point is A, as shown in Figure 34.
Point
FIGURE 34 - MEASUREMENT POINT OF NUMBER OF EFFECTIVE DATA BLOCKS
RECEIVED ON GPRS UL TBF

Unit Times

C900040063
Definition Number of NACK blocks received on GPRS UL TBF
Description During the TBF transmission, MS divides the UL LLC frame into
RLC blocks and sends them to BSS. Only when BSS correctly
receives all these RLC blocks can it recompose the LLC frame.
BBS informs MS of the RLC block reception through Packet
Uplink Ack. For the reply mode, if any RLC block is lost, MS
should transmit again.
Usage The counter counts the number of NACK blocks received on
GPRS UL TBF
Measurement Then counter increments when BSS correctly receives a NACK
Point block. The measurement point is A, as shown in Figure 35.

42 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

FIGURE 35 - MEASUREMENT POINT OF NUMBER OF NACK BLOCKS RECEIVED


ON GPRS UL TBF

Unit Times

C900040064
Definition Number of effective data blocks sent on GPRS DL TBF
Description During the TBF transmission, BSS divides the UL LLC frame into
RLC blocks and sends them to MS. Only when MS correctly
receives all these RLC blocks can it recompose the LLC frame.
MS informs BSS of the RLC block reception through Packet
DownLink Ack/EGPRS Packet Downlink Ack.
Usage The counter counts the number of effective data blocks sent on
GPRS DL TBF
Measurement Then counter increments when Packet DownLink Ack/EGPRS
Point Packet Downlink Ack indicates that MS have correctly received
the RLC block. The measurement point is A1, as shown in Figure
36.

FIGURE 36 - MEASUREMENT POINT OF NUMBER OF EFFECTIVE DATA BLOCKS


SENT ON GPRS DL TBF

MS BSC SGSN

LLC Frame
RLC Block
A1
Packet Downlink Ack
Bitmap indicates some data
blocks fail to arrive
RLC Block(NACK)
A2
LLC Frame
RLC Block

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 43


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040065
Definition Number of NACK blocks sent on GPRS DL TBF
Description During the TBF transmission, BSS divides the UL LLC frame into
RLC blocks and sends them to MS. Only when MS correctly
receives all these RLC blocks can it recompose the LLC frame.
MS informs BSS of the RLC block reception through Packet
DownLink Ack/EGPRS Packet Downlink Ack.
Usage The counter counts the number of NACK blocks sent on GPRS DL
TBF.
Measurement Then counter increments when Packet DownLink Ack/EGPRS
Point Packet Downlink Ack indicates that MS fails to receive the RLC
block. The measurement point is A2, as shown in Figure 37.

FIGURE 37 - MEASUREMENT POINT OF NUMBER OF NACK BLOCKS SENT ON


GPRS DL TBF

MS BSC SGSN

LLC Frame
RLC Block
A1
Packet Downlink Ack
Bitmap indicates some data
blocks fail to arrive
RLC Block(NACK)
A2
LLC Frame
RLC Block

Unit Times

C900040066
Definition Bytes of LLC frame on EGPRS UL data TBF
Description After receiving the RLC blocks reported by MS, UPPB composes
them into the LLC frame and sends it to SGSN. At same time,
UPPB sends the Packet Uplink Ack message to MS by a certain
rule.
Usage The counter counts the bytes of LLC frame on EGPRS UL data
TBF.
Measurement The measurement point is A, as shown in Figure 38.
Point

44 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

FIGURE 38 - MEASUREMENT POINT OF BYTES OF LLC FRAME ON EGPRS UL


DATA TBF

Unit Byte

C900040067
Definition Duration of EGPRS UL data TBF
Description The duration starts when BSS receives the UL access from MS
and ends when BSS receives the data block (CV=0) and all the
other blocks have arrived.
Usage The counter counts the duration of EGPRS UL data TBF.
Measurement The duration lasts from UPPB’s reception of UL TBF
Point establishment request to transmission of Packet Uplink Ack
with FAI set. The measurement point is A, as shown in Figure 39.

FIGURE 39 - MEASUREMENT POINT OF DURATION OF EGPRS UL DATA TBF

Unit Ms

C900040068
Definition Bytes of LLC frame on EGPRS DL data TBF
Description UPPB divides the DL LLC frame into RLC blocks and sends them
to MS. Besides. UPPB sets RRBP by a certain rule. Then MS
reports Packet Downlink Ack/EGPRS Packet Downlink Ack in
the specific UL block.
Usage The counter counts the bytes of LLC frame on EGPRS DL data
TBF.

Confidential and Proprietary Information of ZTE CORPORATION 45


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Measurement The measurement point is A, as shown in Figure 40.


Point
FIGURE 40 - MEASUREMENT POINT OF BYTES OF LLC FRAME ON EGPRS DL
DATA TBF

Unit Byte

C900040069
Definition Duration of EGPRS DL data TBF
Description The duration lasts from BSS’s reception of the UL TBF
establishment request to its reception of Packet Downlink
Ack/EGPRS Packet Downlink Ack (Packet Control Ack in non-
reply mode) with FAI=1 sent from MS.
Usage The counter counts the duration of EGPRS DL data TBF.
Measurement The measurement point is A, as shown in Figure 41.
Point
FIGURE 41 - MEASUREMENT POINT OF DURATION OF EGPRS DL DATA TBF

Unit Ms

C900040070
Definition Number of effective data blocks received on EGPRS UL TBF
Description

46 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

During the TBF transmission, MS divides the UL LLC frame into


RLC blocks and sends them to BSS. Only when BSS receives all
these RLC blocks can it recompose the LLC frame.
Usage The counter counts the number of effective data blocks received
on EGPRS UL TBF.
Measurement The measurement point is A, as shown in Figure 42.
Point
FIGURE 42 - MEASUREMENT POINT OF NUMBER OF EFFECTIVE DATA BLOCKS
RECEIVED ON EGPRS UL TBF

Unit Times

C900040071
Definition Number of NACK blocks received on EGPRS UL TBF
Description During the TBF transmission, MS divides the UL LLC frame into
RLC blocks and sends them to BSS. Only when BSS correctly
receives all these RLC blocks can it recompose the LLC frame.
BBS informs MS of the RLC block reception through Packet
Uplink Ack. For the reply mode, if any RLC block is lost, MS
should transmit again.
Usage The counter counts the number of NACK blocks received on
EGPRS UL TBF.
Measurement Then counter increments when BSS correctly receives a NACK
Point block. The measurement point is A, as shown in Figure 43.

FIGURE 43 - MEASUREMENT POINT OF NUMBER OF NACK BLOCKS RECEIVED


ON EGPRS UL TBF

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 47


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040072
Definition Number of effective data blocks sent on EGPRS DL TBF
Description During the TBF transmission, BSS divides the UL LLC frame into
RLC blocks and sends them to MS. Only when MS correctly
receives all these RLC blocks can it recompose the LLC frame.
MS informs BSS of the RLC block reception through Packet
DownLink Ack/EGPRS Packet Downlink Ack.
Usage The counter counts the number of effective data blocks sent on
EGPRS DL TBF.
Measurement Then counter increments when Packet DownLink Ack/EGPRS
Point Packet Downlink Ack indicates that MS have correctly received
the RLC block. The measurement point is A1, as shown in Figure
44.

FIGURE 44 - MEASUREMENT POINT OF NUMBER OF EFFECTIVE DATA BLOCKS


SENT ON EGPRS DL TBF

MS BSC SGSN

LLC Frame
RLC Block
A1
Packet Downlink Ack
Bitmap indicates some data
blocks fail to arrive
RLC Block(NACK)
A2
LLC Frame
RLC Block

Unit Times

C900040073
Definition Number of NACK blocks sent on EGPRS DL TBF
Description During the TBF transmission, BSS divides the UL LLC frame into
RLC blocks and sends them to MS. Only when MS correctly
receives all these RLC blocks can it recompose the LLC frame.
MS informs BSS of the RLC block reception through Packet
DownLink Ack/EGPRS Packet Downlink Ack.
Usage The counter counts the number of NACK blocks sent on EGPRS
DL TBF.
Measurement
Point

48 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Then counter increments when Packet DownLink Ack/EGPRS


Packet Downlink Ack indicates that MS fails to receive the RLC
block. The measurement point is A2, as shown in Figure 45.

FIGURE 45 - MEASUREMENT POINT OF NUMBER OF NACK BLOCKS SENT ON


EGPRS DL TBF

MS BSC SGSN

LLC Frame
RLC Block
A1
Packet Downlink Ack
Bitmap indicates some data
blocks fail to arrive
RLC Block(NACK)
A2
LLC Frame
RLC Block

Unit Times

C900040074
Definition Number of GPRS DL LLC frames
Description The DL GIPB sends DL UnitData to UPPB through IP packets.
tQoSProfile Tbit in DL UnitData identifies whether data or
signaling is transmitted. UPPB applies to CMP to establish DL TBF
(radio access capacity to carry MS) and according to the CMP
request, establishes EGPRS/GPRS TBF.
Usage The counter counts the number of GPRS DL LLC frames.
Measurement The measurement point is A, as shown in Figure 46.
Point
FIGURE 46 - MEASUREMENT POINT OF NUMBER OF GPRS DL LLC FRAMES

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 49


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040075
Definition Number of discarded GPRS DL LLC frames due to buffer overflow
Description The DL GIPB sends DL UnitData to UPPB through IP packets. If
UPPB fails to acquire buffer, then it will send the LLC Discard
message to SGSN.
Usage The counter counts the number of discarded GPRS DL LLC
frames due to buffer overflow.
Measurement The measurement point is A, as shown in Figure 47.
Point
FIGURE 47 - MEASUREMENT POINT OF NUMBER OF DISCARDED GPRS DL
LLC FRAMES DUE TO BUFFER OVERFLOW

Unit Times

C900040076
Definition Number of discarded GPRS DL LLC frames due to life time
expiration
Description The DL GIPB sends DL UnitData to UPPB through IP packets. If
UPPB fails to send them before the LLC frame life time expires,
then it will send the LLC Discard message to SGSN.
Usage The counter counts the number of discarded GPRS DL LLC
frames due to life time expiration.
Measurement The measurement point is A, as shown in Figure 48.
Point
FIGURE 48 - MEASUREMENT POINT OF NUMBER OF DISCARDED GPRS DL
LLC FRAMES DUE TO LIFE TIME EXPIRATION

50 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Unit Times

C900040077
Definition Number of discarded GPRS DL LLC frames due to other reasons
Description The DL GIPB sends DL UnitData to UPPB through IP packets. If
UPPB fails to send them for reasons other than the above two in
C900040075 and C900040076, then it will send the LLC
Discard message to SGSN.
Usage The counter counts the number of discarded GPRS DL LLC
frames due to other reasons than the above two in C900040075
and C900040076.
Measurement The measurement point is A, as shown in Figure 49.
Point

FIGURE 49 - MEASUREMENT POINT OF NUMBER OF DISCARDED GPRS DL


LLC FRAMES DUE TO OTHER REASONS

Unit Times

C900040078
Definition Number of DL dummy control blocks on PACCH
Description If there is no other RLC/MAC block available in the network, BSS
will transmit the DUMMY blocks to MS for UL transmission.
The counter counts the number of DL dummy control blocks sent
by BSC on PACCH in the packet transmission mode.
Measurement If the DL control block sent from BTS to MS is a DL Dummy
Point control block, the counter increments. The measurement point is
A, as shown in Figure 50.

Confidential and Proprietary Information of ZTE CORPORATION 51


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 50 - MEASUREMENT POINT OF NUMBER OF DL DUMMY CONTROL


BLOCKS ON PACCH

MS BSS

Packet Downlink Dummy Control


A

Unit Times

C900040079
Definition Number of UL dummy control blocks on PACCH
Description Similar to C900040078, this counter counts the number of UL
dummy control blocks sent by BSC on PACCH in the packet
transmission mode.
Measurement If the DL control block sent from BTS to MS is an UL Dummy
Point control block, the counter increments. The measurement point is
A, as shown in Figure 51.

FIGURE 51 - MEASUREMENT POINT OF NUMBER OF UL DUMMY CONTROL


BLOCKS ON PACCH

MS BSS

Packet Uplink Dummy Control


A

Unit Times

C900040080
Definition Number of DL RLC blocks on PACCH(excluding dummy block)
Description This counter counts the number of DL RLC blocks expect DUMMY
blocks sent from BSC to MS through BTS on PACCH.
Usage The counter counts the number of DL RLC blocks expect DUMMY
blocks sent by BSC on PACCH.
Measurement
Point

52 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

When BSC sends a DL control block (except DUMMY block) to MS


through BTS, the counter increments. The measurement point is
A, as shown in Figure 52.

FIGURE 52 - MEASUREMENT POINT OF NUMBER OF DL RLC BLOCKS ON


P AC C H ( E X C L U D I N G D U M M Y B L O C K )

Unit Times

C900040081
Definition Number of DL RLC pending blocks in CS1 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL pending RLC
blocks from BSC to MS, with coding method of CS1.
Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of CS1.
Measurement When BSC sends a pending RLC block whose coding method is
Point CS1 to MS, the counter increments. The measurement point is A,
as shown in Figure 53.

FIGURE 53 - MEASUREMENT POINT OF NUMBER OF DL RLC PENDING BLOCKS


ON PDTCH

Unit Times

C900040082
Definition Number of DL RLC pending blocks in CS2 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL pending RLC
blocks from BSC to MS, with coding method of CS2.

Confidential and Proprietary Information of ZTE CORPORATION 53


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of CS2.
Measurement When BSC sends a pending RLC block whose coding method is
Point CS2 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 53.
Unit Times

C900040083
Definition Number of DL RLC pending blocks in CS3 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL pending RLC
blocks from BSC to MS, with coding method of CS3.
Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of CS3.
Measurement When BSC sends a pending RLC block whose coding method is
Point CS3 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 53.
Unit Times

C900040084
Definition Number of DL RLC pending blocks in CS4 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL pending RLC
blocks from BSC to MS, with coding method of CS4.
Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of CS4.
Measurement When BSC sends a pending RLC block whose coding method is
Point CS4 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 53.
Unit Times

C900040085
Definition Number of DL RLC NACK blocks in CS1 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of CS1.

54 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Usage This counter counts the number of DL retransmitted RLC blocks


sent on PDTCH, with coding method of CS1.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is CS1 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 54.

FIGURE 54 - MEASUREM ENT POINT OF NUMBER OF DL RLC N ACK BLOCKS


ON PDTCH

Unit Times

C900040086
Definition Number of DL RLC NACK blocks in CS2 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of CS2.
Usage This counter counts the number of DL retransmitted RLC blocks
sent on PDTCH, with coding method of CS2.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is CS2 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 54.
Unit Times

C900040087
Definition Number of DL RLC NACK blocks in CS3 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of CS3.
Usage This counter counts the number of DL retransmitted RLC blocks
sent on PDTCH, with coding method of CS3.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is CS3 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 54.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 55


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040088
Definition Number of DL RLC NACK blocks in CS4 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of CS4.
Usage This counter counts the number of DL retransmitted RLC blocks
sent on PDTCH, with coding method of CS4.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is CS4 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 54.
Unit Times

C900040089
Definition Number of DL RLC new blocks in CS1 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
CS1.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of CS1.
Measurement When BSC sends first-transmitted RLC block (with coding
Point method of CS1) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.

FIGURE 55 – MEASUREMENT POINT OF NUMBER OF DL RLC NEW BLOCKS ON


PDTCH

Unit Times

C900040090
Definition Number of DL RLC new blocks in CS2 on PDTCH
Description

56 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

After BSC receives DownLink Ack message, it decides whether


to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
CS2.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of CS2.
Measurement When BSC sends first-transmitted RLC block (with coding
Point method of CS2) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.
Unit Times

C900040091
Definition Number of DL RLC new blocks in CS3 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
CS3.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of CS3.
Measurement When BSC sends first-transmitted RLC block (with coding
Point method of CS3) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.
Unit Times

C900040092
Definition Number of DL RLC new blocks in CS4 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
CS4.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of CS4.
Measurement When BSC sends first-transmitted RLC block (with coding
Point method of CS4) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 57


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040093
Definition Number of UL RLC blocks excluding dummy blocks on PACCH
Description This counter counts the number of UL RLC blocks expect DUMMY
blocks sent from MS to BSC through BTS on PACCH.
Usage The counter counts the number of uplink RLC blocks expect
DUMMY blocks received by BSC on PACCH.
Measurement When BSC receives an UL control block (except the DUMMY
Point block) from MS, the counter increments. The measurement point
is A, as shown in Figure 56.

FIGURE 56 - MEASUREMENT POINT OF NUMBER OF UL RLC BLOCKS


EXCLUDING DUMMY BLOCKS ON P ACCH

Unit Times

C900040094
Definition Number of UL RLC pending blocks in CS1 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL CS1-
coded pending RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL CS1-coded pending
RLC blocks received by BSC on PDTCH.
Measurement When BSC receives CS1-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.

FIGURE 57 - MEASUREMENT POINT OF NUMBER OF UL RLC PENDING BLOCKS


ON PDTCH

MS BTS BSC
UL pending RLC block
RLC block (coding scheme can be
CS1 ~ CS4, MCS1 ~
MCS9)
A

Unit Times

58 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

C900040095
Definition Number of UL RLC pending blocks in CS2 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL CS2-
coded pending RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL CS2-coded pending
RLC blocks received by BSC on PDTCH.
Measurement When BSC receives CS2-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.
Unit Times

C900040096
Definition Number of UL RLC pending blocks in CS3 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL CS3-
coded pending RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL CS3-coded pending
RLC blocks received by BSC on PDTCH.
Measurement When BSC receives CS3-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.
Unit Times

C900040097
Definition Number of UL RLC pending blocks in CS4 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL CS4-
coded pending RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL CS4-coded pending
RLC blocks received by BSC on PDTCH.
Measurement When BSC receives CS4-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 59


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040098
Definition Number of UL RLC NACK blocks in CS1 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL CS1-
coded retransmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL CS1-coded
retransmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives CS1-coded UL retransmitted RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 58.

FIGURE 58 - MEASUREM ENT POINT OF NUMBER OF UL RLC N ACK BLOCKS


ON PDTCH

Unit Times

C900040099
Definition Number of UL RLC NACK blocks in CS2 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL CS2-
coded retransmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL CS2-coded
retransmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives CS2-coded UL retransmitted RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C900040100
Definition Number of UL RLC NACK blocks in CS3 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending

60 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

RLC block. This counter counts the number of useful UL CS3-


coded retransmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL CS3-coded
retransmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives CS3-coded UL retransmitted RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C900040101
Definition Number of UL RLC NACK blocks in CS4 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL CS4-
coded retransmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL CS4-coded
retransmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives CS4-coded UL retransmitted RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C900040102
Definition Number of UL RLC new blocks in CS1 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL CS1-
coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL CS1-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives CS1-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.

Confidential and Proprietary Information of ZTE CORPORATION 61


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 59 – MEASUREMENT POINT OF NUMBER OF UL RLC NEW BLOCKS ON


PDTCH

Unit Times

C900040103
Definition Number of UL RLC new blocks in CS2 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL CS2-
coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL CS2-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives CS2-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.
Unit Times

C900040104
Definition Number of UL RLC new blocks in CS3 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL CS3-
coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL CS3-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives CS3-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.
Unit Times

C900040105
Definition Number of UL RLC new blocks in CS4 on PDTCH
Description

62 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

After receiving UL data block, BSC decides whether it is


retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL CS4-
coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL CS4-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives CS4-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.
Unit Times

C900040106
Definition Number of UL data blocks received on PDTCH
Description When MS transmits UL RLC blocks to BSC through BTS, this
counter counts the number of data blocks received by BSC,
including the retransmitted RLC blocks, blocks to be confirmed
and the first-transmitted blocks.
Usage The counter counts the number of data blocks received by UL
PDTCH.
Measurement When MS transmits an UL RLC block to BSC through BTS
Point (including the retransmitted RLC blocks, blocks to be confirmed
and the first-transmitted blocks), this counter increments.
Unit Times

C900040107
Definition Number of DL data blocks sent on PDTCH
Description When BSC transmits DL RLC blocks to BTS, this counter counts
the number of data blocks sent from BSC, including the
retransmitted RLC blocks, blocks to be confirmed and the first-
transmitted blocks.
Usage The counter counts the number of data blocks sent by DL PDTCH.
Measurement When BSC transmits a DL RLC block to BTS (including the
Point retransmitted RLC blocks, blocks to be confirmed and the first-
transmitted blocks), this counter increments.
Unit Times

C900040108
Definition Number of GPRS DL TBF establishment requests
Description

Confidential and Proprietary Information of ZTE CORPORATION 63


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

The counter counts the number of GPRS DL TBF establishment


requests received by PS control plane when BSC attempts to
establish DL GPRS TBFs. It is the sum of CCCH/PCCCH requests
(C901170002) and PACCH requests (C901170003).
Usage The counter collects information about the frequency of DL
establishment requests received by PS control plane when BSC
attempts to establish DL GPRS TBFs.
Measurement This counter increments in the following two cases:
Point
„ When PS control plane receives a DL TBF establishment
request from PS user plane, this counter increments.
„ When UL GPRS TBF exists and DL GPRS TBF is to be
established, if PS control plane receives the DL assignment
message from PS user plane, this counter increments.
Unit Times

C900040109
Definition Number of GPRS DL TBF establishment failure due to database
allocation failure
Description The counter counts the number of GPRS DL TBF establishment
failure due to database allocation failure.
Usage The counter collects information about the frequency of channel
allocation failures when BSC attempts to establish DL GPRS TBFs.
Measurement This counter increments in the following two cases:
Point
„ When PS control plane receives the DL TBF establishment
request from PS user plane, it will apply to database for
resources. If it fails to obtain the resources, this counter
increments. The measurement point is A, as shown in Figure
60.

FIGURE 60 - MEASUREMENT POINT OF ALLOCATION F AILURES AFTER


RECEIVING DL TBF ESTABLISHMENT REQUEST

„ When MS has already established an UL GPRS TBF and DL


GPRS TBF is to be established, if PS control plane receives
the DL TBF assignment message from PS user plane, it will

64 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

apply to database for resources. If it fails to obtain the


resources, this counter increments. The measurement point
is A, as shown in Figure 61.

FIGURE 61 - MEASUREMENT POINT OF ALLOCATION F AILURES AFTER


RECEIVING DL TBF ASSIGNMENT MESSAGE

Unit Times

C900040110
Definition Number of GPRS DL TBF resource reallocation requests due to
UL TBF establishment
Description The counter counts the number of GPRS DL TBF resource
reallocation requests due to UL TBF establishment.
Usage The counter collects information about the frequency of GPRS DL
TBF resource reallocation requests.
Measurement When MS has already established a DL GPRS TBF, if PS control
Point plane receives an UL TBF assignment message from PS user
plane, this counter increments. The measurement point is A, as
shown in Figure 62.

FIGURE 62 - MEASUREMENT POINT OF NUMBER OF GPRS DL TBF RESOURCE


REALLOCATION REQUESTS DUE TO UL TBF ESTABLISHMENT

PS control
PS user plane plane

UL TBF assignment

Unit Times

C900040111
Definition Number of GPRS DL TBF resource reallocation failure due to UL
TBF establishment

Confidential and Proprietary Information of ZTE CORPORATION 65


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Description If MS has already established a DL GPRS TBF and it needs to


establish an UL TBF on PACCH, PS control plane should apply to
database for resources. The counter counts the number of DL
resource reallocation failures caused by failed UL TBF
establishment allocation.
Usage The counter collects information about the frequency of GPRS DL
resource reallocation failures caused by failed UL TBF
establishment allocation.
Measurement When MS has already established a DL GPRS TBF, if PS control
Point plane receives an UL TBF assignment message from PS user
plane, it will apply to database for resources. If it fails to obtain
the resources, this counter increments. The measurement point
is A, as shown in Figure 63.

FIGURE 63 - MEASUREMENT POINT OF NUMBER OF GPRS DL TBF RESOURCE


REALLOCATION FAILURE DUE TO UL TBF ESTABLISHMENT

Unit Times

C900040112
Definition Number of GPRS DL TBF resource reallocation requests due to
LLC transmission
Description This counter counts the number of resource reallocation requests
that PS control plane receives from PS user plane caused by
UL/DL LLC frame changes during the DL GPRS TBF transmission.
Usage This counter collects information about the frequency of resource
reallocation requests received by PS control plane during the DL
GPRS TBF transmission.
Measurement When PS control plane receives a resource reallocation request
Point from PS user plane, if the current DL GPRS TBF exists, this
counter increments. The measurement point is A, as shown in
Figure 64.

66 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

FIGURE 64 - MEASUREMENT POINT OF NUMBER OF GPRS DL TBF RESOURCE


REALLOCATION REQUESTS DUE TO LLC TRANSMISSION

PS user plane PS control plane

Resource reallocation request


A

Unit Times

C900040113
Definition Number of GPRS DL TBF resource reallocation failure due to LLC
transmission
Description During the DL GPRS TBF transmission, because UL/DL LLC frame
changes, PS user plane sends a resource reallocation request to
PS control plane. After receiving the request, PS control plane
applies to database for resources. This counter counts the
number of failed resource allocations.
Usage This counter collects information about the frequency of failed
resource allocations during the DL GPRS TBF transmission after
PS control plane receives the resource reallocation request and
applies to database for resources.
Measurement After PS control plane receives a resource reallocation request
Point from PS user plane and applies to database for resources, if it
fails to obtain the resources, this counter increments, as A
shown in Figure 65.

FIGURE 65 - MEASUREMENT POINT OF NUMBER OF GPRS DL TBF RESOURCE


REALLOCATION FAILURE DUE TO LLC TRANSMISSION

Unit Times

C900040114
Definition Number of EGPRS DL TBF establishment requests
Description

Confidential and Proprietary Information of ZTE CORPORATION 67


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

The counter counts the number of EGPRS downlink TBF


establishment requests received by control plane. It is the sum
of CCCH/PCCCH requests (C901180002) and PACCH requests
(C901180003).
Usage The counter collects information about the frequency of DL
establishment requests received by the control plane when BSC
attempts to establish DL EGPRS TBFs.
Measurement This counter increments in the following two cases:
Point
„ When PS control plane receives a DL TBF establishment
request from PS user plane, this counter increments.
„ When UL EGPRS TBF exists and DL EGPRS TBF is to be
established, if PS control plane receives the DL assignment
message from PS user plane, this counter increments.
Unit Times

C900040115
Definition Number of EGPRS DL TBF establishment failure due to database
allocation failure
Description The counter counts the number of channel allocation failures
when BSC attempts to establish DL EGPRS TBFs and RANPS
applies to database for resources.
Usage The counter collects information about the frequency of channel
allocation failures when BSC attempts to establish DL EGPRS
TBFs and RANPS applies to database for resources.
Measurement This counter increments in the following two cases:
Point
„ When PS control plane receives the DL TBF establishment
request from PS user plane, it will apply to database for
resources. If it fails to obtain the resources, this counter
increments. The measurement point is A, as shown in Figure
60.
„ When UL EGPRS TBF exists and DL EGPRS TBF is to be
established, if PS control plane receives the DL TBF
assignment message from PS user plane, it will apply to
database for resources. If it fails to obtain the resources, this
counter increments. The measurement point is A, as shown
in Figure 61.
Unit Times

C900040116
Definition Number of EGPRS DL TBF resource reallocation requests due to
UL TBF establishment
Description

68 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

The counter counts the number of EGPRS downlink TBF resource


reallocation requests (concurrent PACCH UL TBF establishment
request).
Usage The counter collects information about the frequency of EGPRS
downlink TBF resource reallocation requests.
Measurement When MS has already established a DL EGPRS TBF, if PS control
Point plane receives an UL TBF assignment message from PS user
plane, this counter increments. The measurement point is A, as
shown in Figure 62.
Unit Times

C900040117
Definition Number of EGPRS DL TBF resource reallocation failure due to UL
TBF establishment
Description If MS has already established a DL EGPRS TBF and it needs to
establish an UL TBF on PACCH, PS control plane should apply to
database for resources. The counter counts the number of DL
resource reallocation failures caused by failed UL TBF
establishment allocation.
Usage The counter collects information about the frequency of EGPRS
DL resource reallocation failures caused by failed UL TBF
establishment allocation.
Measurement When MS has already established a DL EGPRS TBF, if PS control
Point plane receives an UL TBF assignment message from PS user
plane, it will apply to database for resources. If it fails to obtain
the resources, this counter increments. The measurement point
is A, as shown in Figure 63.
Unit Times

C900040118
Definition Number of EGPRS DL TBF resource reallocation requests due to
LLC transmission
Description This counter counts the number of resource reallocation requests
that PS control plane receives from PS user plane caused by
UL/DL LLC frame changes during the DL EGPRS TBF
transmission.
Usage This counter collects information about the frequency of resource
reallocation requests received by PS control plane during the DL
EGPRS TBF transmission.
Measurement When PS control plane receives a resource reallocation request
Point from PS user plane, if the current DL EGPRS TBF exists, this
counter increments, as A shown in Figure 64.

Confidential and Proprietary Information of ZTE CORPORATION 69


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Unit Times

C900040119
Definition Number of EGPRS DL TBF resource reallocation failure due to
LLC transmission
Description During the DL EGPRS TBF transmission, because UL/DL LLC
frame changes, PS user plane sends a resource reallocation
request to PS control plane. After receiving the request, PS
control plane applies to database for resources. This counter
counts the number of failed resource allocations.
Usage This counter collects information about the frequency of failed
resource allocations during the DL EGPRS TBF transmission after
PS control plane receives the resource reallocation request and
applies to database for resources.
Measurement After PS control plane receives a resource reallocation request
Point from PS user plane and applies to database for resources, if it
fails to obtain the resources, this counter increments, as A
shown in Figure 65.
Unit Times

C900040120
Definition Number of GPRS UL TBF establishment requests
Description The counter counts the number of all channel requests when MS
attempts to establish GPRS UL TBFs. It is the sum of CCCH
requests (C901190002), PCCCH requests (C901190004) and
PACCH requests (C901190006).
Usage The counter collects information about the frequency of channel
requests when MS attempts to establish GPRS services.
Measurement This counter increments in the following three cases:
Point
„ When BSC receives a CCCH request originated by MS, this
counter increments.
„ When BSC receives a PCCCH request originated by MS, this
counter increments.
„ When BSC receives a PACCH request originated by MS and
user plane sends a resource request to control plane, this
counter increments.
Unit Times

70 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

C900040121
Definition Number of GPRS UL TBF establishment failure due to database
allocation failure
Description The counter counts the number of GPRS UL TBF establishment
channel allocation failures.
Usage The counter collects information about the frequency of channel
allocation failures when the system attempts to establish UL
GPRS TBFs.
Measurement This counter increments in the following three cases:
Point
„ When PS control plane receives a CCCH request from MS, it
will apply to database for resources. If it fails to obtain the
resources, this counter increments. The measurement point
is A, as shown in Figure 66.

FIGURE 66 - MEASUREMENT POINT OF ALLOCATION F AILURES AFTER


RECEIVING CCCH REQUEST

„ When PS control plane receives a PCCCH request from MS, it


will apply to database for resources. If it fails to obtain the
resources, this counter increments. The measurement point
is A, as shown in Figure 67.

FIGURE 67 - MEASUREMENT POINT OF ALLOCATION F AILURES AFTER


RECEIVING PCCCH REQUEST

„ When MS has already established a DL GPRS TBF, if PS


control plane receives an UL TBF assignment message from
PS user plane, it will apply to database for resources. If it
fails to obtain the resources, this counter increments. The
measurement point is A, as shown in Figure 68.

Confidential and Proprietary Information of ZTE CORPORATION 71


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 68 - MEASUREMENT POINT OF ALLOCATION F AILURES (DL GPRS


TBF EXISTS)

Unit Times

C900040122
Definition Number of GPRS UL TBF resource reallocation requests due to
DL TBF establishment
Description The counter counts the number of RS UL TBF resource
reallocation requests due to DL TBF establishment.
Usage The counter collects information about the frequency of GPRS UL
TBF resource reallocation requests.
Measurement When MS has already established an UL GPRS TBF, if PS control
Point plane receives a DL TBF assignment message from PS user
plane, this counter increments. The measurement point is A, as
shown in Figure 69.

FIGURE 69 - MEASUREMENT POINT OF NUMBER OF GPRS UL TBF RESOURCE


REALLOCATION REQUESTS DUE TO DL TBF ESTABLISHMENT

Unit Times

C900040123
Definition Number of GPRS UL TBF resource reallocation failure due to DL
TBF establishment
Description If MS has already established an UL GPRS TBF and it needs to
establish a DL TBF on PACCH, PS control plane should apply to

72 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

database for resources. The counter counts the number of UL


resource reallocation failures caused by failed DL TBF
establishment allocation.
Usage The counter collects information about the frequency of GPRS UL
resource reallocation failures caused by failed DL TBF
establishment allocation.
Measurement When MS has already established an UL GPRS TBF, if PS control
Point plane receives a DL TBF assignment message from PS user
plane, it will apply to database for resources. If it fails to obtain
the resources, this counter increments. The measurement point
is A, as shown in Figure 61.
Unit Times

C900040124
Definition Number of GPRS UL TBF resource reallocation requests due to
LLC transmission
Description This counter counts the number of resource reallocation requests
that PS control plane receives from PS user plane caused by
UL/DL LLC frame changes during the UL GPRS TBF transmission.
Usage This counter collects information about the frequency of resource
reallocation requests received by PS control plane during the UL
GPRS TBF transmission.
Measurement When PS control plane receives a resource reallocation request
Point from PS user plane, if the current UL GPRS TBF exists, this
counter increments. The measurement point is A, as shown in
Figure 64.
Unit Times

C900040125
Definition Number of GPRS UL TBF resource reallocation failure due to LLC
transmission
Description During the UL GPRS TBF transmission, because UL/DL LLC frame
changes, PS user plane sends a resource reallocation request to
PS control plane. After receiving the request, PS control plane
applies to database for resources. This counter counts the
number of failed resource allocations.
Usage This counter collects information about the frequency of failed
resource allocations during the UL GPRS TBF transmission after
PS control plane receives the resource reallocation request and
applies to database for resources.
Measurement After PS control plane receives a resource reallocation request
Point from PS user plane and applies to database for resources, if it

Confidential and Proprietary Information of ZTE CORPORATION 73


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

fails to obtain the resources, this counter increments, as A


shown in Figure 65.
Unit Times

C900040126
Definition Number of GPRS UL TBF resource reallocation requests for
resource request
Description This counter counts the number of resource allocation requests
that PS control plane receives from MS during the UL GPRS TBF
transmission.
Usage This counter collects information about the frequency of resource
allocation requests received by PS control plane during the UL
GPRS TBF transmission (including 2-step UL access and UL TBF
transmission).
Measurement When PS control plane receives a resource allocation request
Point from PS user plane, this counter increments, as A shown in
Figure 70.

FIGURE 70 - MEASUREMENT POINT OF NUMBER OF GPRS UL TBF RESOURCE


REALLOCATION REQUESTS FOR RESOURCE REQUEST
PS control PS user
plane plane
Resource allocation request

Unit Times

C900040127
Definition Number of GPRS UL TBF resource reallocation failure due to
database allocation failure for resource request
Description During the UL GPRS TBF transmission, after receiving the
resource allocation request from MS, PS control plane applies to
database for resources. This counter counts the number of failed
resource allocations.
Usage This counter collects information about the frequency of failed
resource allocations during the UL GPRS TBF transmission
(including 2-step UL access and UL TBF transmission) after PS
control plane receives the resource allocation request from MS
and applies to database for resources.
Measurement After PS control plane receives a resource reallocation request
Point from MS and applies to database for resources, if it fails to

74 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

obtain the resources, this counter increments, as A shown in


Figure 71.

FIGURE 71 – FAILING TO REQUEST FOR RESOURCE FROM DAT AB ASE

Unit Times

C900040128
Definition Number of EGPRS UL TBF establishment requests
Description The counter counts the number of all channel requests when MS
attempts to establish EDGE UL TBFs. It is the sum of CCCH
requests (C901200003), PCCCH requests (C901200005) and
PACCH requests (C901200006).
Usage The counter collects information about the frequency of channel
requests when MS attempts to establish EDGE services.
Measurement This counter increments in the following three cases:
Point
„ When BSC receives an EDGE CCCH request originated by MS,
this counter increments.
„ When BSC receives an EDGE PCCCH request originated by
MS, this counter increments.
„ When BSC receives an EDGE PACCH request originated by
MS and user plane sends a resource request to control plane,
this counter increments.
Unit Times

C900040129
Definition Number of EGPRS UL TBF establishment failure due to database
allocation failure
Description The counter counts the number of EGPRS UL TBF establishment
channel allocation failures.
Usage The counter collects information about the frequency of channel
allocation failures when the system attempts to establish UL
EGPRS TBFs.

Confidential and Proprietary Information of ZTE CORPORATION 75


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Measurement This counter increments in the following two cases:


Point
„ When PS control plane receives an EGPRS channel request
on CCCH or an EGPRS Packet channel request on PCCCH
from MS, it will apply to database for resources. If it fails to
obtain the resources, this counter increments. The
measurement point is A, as shown in Figure 72.

FIGURE 72 – MEASUREMENT POINT OF NUMBER OF EGPRS UPLINK TBF


ESTABLISHMENT CHANNEL ALLOCATION FAILURES

„ When MS has already established a DL EGPRS TBF, if PS


control plane receives an UL TBF assignment message from
PS user plane, it will apply to database for resources. If it
fails to obtain the resources, this counter increments. The
measurement point is A, as shown in Figure 68.
Unit Times

C900040130
Definition Number of EGPRS UL TBF resource reallocation requests due to
DL TBF establishment
Description The counter counts the number of EGPRS UL TBF resource
reallocation requests due to DL TBF establishment.
Usage The counter collects information about the frequency of EGPRS
UL TBF resource reallocation requests.
Measurement
When MS has already established an UL EGPRS TBF, if PS control
Point
plane receives a DL TBF assignment message from PS user
plane, this counter increments. The measurement point is A, as
shown in Figure 69.

Unit Times

C900040131
Definition Number of EGPRS UL TBF resource reallocation failure due to DL
TBF establishment
Description

76 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

If MS has already established an UL EGPRS TBF and it needs to


establish a DL TBF on PACCH, PS control plane should apply to
database for resources. The counter counts the number of UL
resource reallocation failures caused by failed DL TBF
establishment allocation.
Usage The counter collects information about the frequency of EGPRS
UL resource reallocation failures caused by failed DL TBF
establishment allocation.
Measurement When MS has already established an UL EGPRS TBF, if PS control
Point plane receives a DL TBF assignment message from PS user
plane, it will apply to database for resources. If it fails to obtain
the resources, this counter increments. The measurement point
is A, as shown in Figure 61.
Unit Times

C900040132
Definition Number of EGPRS UL TBF resource reallocation requests due to
LLC transmission
Description This counter counts the number of resource reallocation requests
that PS control plane receives from PS user plane caused by
UL/DL LLC frame changes during the UL EGPRS TBF transmission.
Usage This counter collects information about the frequency of resource
reallocation requests received by PS control plane during the UL
EGPRS TBF transmission.
Measurement When PS control plane receives a resource reallocation request
Point from PS user plane, this counter increments, as A shown in
Figure 64.
Unit Times

C900040133
Definition Number of EGPRS UL TBF resource reallocation failure due to
LLC transmission
Description During the UL EGPRS TBF transmission, because UL/DL LLC
frame changes, PS user plane sends a resource reallocation
request to PS control plane. After receiving the request, PS
control plane applies to database for resources. This counter
counts the number of failed resource allocations.
Usage This counter collects information about the frequency of failed
resource allocations during the UL EGPRS TBF transmission after
PS control plane receives the resource reallocation request and
applies to database for resources.
Measurement After PS control plane receives a resource reallocation request
Point from PS user plane and applies to database for resources, if it

Confidential and Proprietary Information of ZTE CORPORATION 77


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

fails to obtain the resources, this counter increments, as A


shown in Figure 65.
Unit Times

C900040134
Definition Number of EGPRS UL TBF resource reallocation requests for
resource request
Description This counter counts the number of resource allocation requests
that PS control plane receives from MS during the UL EGPRS TBF
transmission.
Usage This counter collects information about the frequency of resource
allocation requests received by PS control plane during the UL
EGPRS TBF transmission (including 2-step UL access and UL TBF
transmission).
Measurement When PS control plane receives a resource allocation request
Point from PS user plane, this counter increments, as A shown in
Figure 70.
Unit Times

C900040135
Definition Number of EGPRS UL TBF resource reallocation failure due to
database allocation failure
Description During the UL EGPRS TBF transmission, after receiving the
resource allocation request from MS, PS control plane applies to
database for resources. This counter counts the number of failed
resource allocations.
Usage This counter collects information about the frequency of failed
resource allocations during the UL EGPRS TBF transmission
(including 2-step UL access and UL TBF transmission) after PS
control plane receives the resource allocation request from MS
and applies to database for resources.
Measurement After PS control plane receives a resource reallocation request
Point from MS and applies to database for resources, if it fails to
obtain the resources, this counter increments, as A shown in
Figure 71.
Unit Times

C900040136
Definition Number of available PDCH
Description

78 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

This counter counts the number of available PDCH in a cell. The


PDCH that can be assigned include dynamic and static PDCH
both idle and occupied.
Usage This counter is used to find out the number of available PDCH in
the serving cell.
Measurement The counter’s value can be obtained by querying the database
Point when periodic measurement data is reported.
Unit Times

C900040137
Definition Number of forcing conversation dynamic from PDCH to TCH by
BSC
Description iBSC supports dynamic radio channel function. The counter
records number of times of reclaiming dynamic PDCH in idle
state so as to use them as TCH/F.
Usage This counter is used to find out the busy level and density of PS
service in the serving cell and use it as reference to decide
whether to set static PDCH or not.
Measurement The counter increments when dynamic PDCH is idle and the
Point database starts reclaiming dynamic PDCH.
Unit Times

C900040138
Definition Number of PDCH used by TBF in each cell
Description This counter counts the sum of PDCH used by all TBF in the
serving cell.
Usage This counter is used to find out the condition of multi-timeslot
allocation in the serving cell.
Measurement The counter’s value can be obtained by querying the database
Point when periodic measurement data is reported.
Unit Times

C900040139
Definition Maximum number of used PDCH
Description This counter records the maximum number of used PDCH in a
cell within the measurement period. It reflects the occupancy
and busy level of PDCH.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 79


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

This counter is used to find out the busy level of the cell TCH/F
channel. It could be used as a reference for whether to increase
PDCH channel configuration.
Measurement This counter increments in the following three cases:
Point
„ Request for database
„ Release database
„ Report periodic measurement data
Unit Times

C900040140
Definition Average number of used PDCH
Description This counter records the average number of used PDCH in a cell
within the measurement period.
Usage This counter is used to find out the busy level of the cell TCH/F
channel. It could be used as a reference for whether to increase
PDCH channel configuration.
Measurement This counter increments in the following three cases:
Point
„ Request for database
„ Release database
„ Report periodic measurement data
Unit Times

C900040141
Definition Number of GPRS DL TBF establishment requests before T3192
expiration
Description During the running of T3193 of DL GPRS TBF, BSC receives DL
LLC frame again, then it performs DL assignment on PACCH of
the DL TBF.
This counter counts the number of times of establishing new DL
TBF.
Measurement After the DL GPRS TBF transmits all LLC frames and the DL RLC
Point block with FBI = 1, T3193 is started. During T3193 running,
when BSC receives new LLC frame and sends DL assignment,
this counter increments.
The measurement point is A, as shown in Figure 73.

80 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

FIGURE 73 –MEASUREMENT POINT OF NUMBER OF GPRS DL TBF


ESTABLISHMENT REQUESTS BEFORE T3192 EXPIRATION

MS BSC SGSN
LLC Frame
RLC Block
LLC Frame
RLC Block
RLC Block(FBI=1)
Start T3193

LLC Frame
Packet Downlink Assignment
A

Unit Times

C900040142
Definition Number of GPRS DL TBF establishment using existing DL TBF
resource
Description When establishing EGPRS DL TBF under UL transmission status,
the user plane needs not to request control plane for DL
resource if having saved DL TBF resource of last time. It uses
the existing resource for DL assignment. This counter records
the number of GPRS DL TBF establishment using existing DL TBF
resource.
Measurement
During the UL GPRS TBF transmission, when BSC receives the
Point
DL LLC frame, it uses the existing resource to establish DL GPRS
TBF. The measurement point is as A, as shown in Figure 74.

FIGURE 74 –MEASUREMENT POINT OF GPRS DL TBF ESTABLISHMENT USING


EXISTING DL TBF RESOURCE

MS BSC SGSN

RLC Block
RLC Block
LLC Frame
Packet Downlink Assignment
(Packet Timeslot Reconfigure)
A
RLC Block

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 81


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040143
Definition Number of GPRS DL TBF establishment requests on PACCH
Description Under UL transmission status, it is necessary to establish DL TBF
transmission when user plane receives DL LLC Frame from SGSN.
If user plane has not saved DL TBF resource, then user plane
requests control plane for resource.
This counter counts the number of times of requesting control
plane for resource to establish GPRS DL TBF on PACCH.

Note:
Here, user plane refers to the UPPB of iBSC, and control plane
refers to the CMP of iBSC.

Measurment The measurement point is as A1, as shown in Figure 75.


Point
FIGURE 75 –MEASUREMENT POINT OF NUMBER OF GPRS DL TBF
ESTABLISHM ENT REQUESTS ON P ACCH

MS BSC user plane BSC control plane SGSN

RLC Block
RLC Block
LLC Frame (no record downlink resource)

A1
Downlink Assign Request
Packet Downlink Assignment Resource Assignment
(Packet Timeslot Reconfigure)

A2

Unit Times

C900040144
Definition Number of GPRS DL TBF establishment requests on
CCCH/PCCCH
Description When MS is in packet idle status, after BSC receives DL LLC
frame from SGSN, BSC initiates the process of establishing DL
TBF which is assigned on CCCH or PCCCH. BSC user plane first
sends the request for DL establishment to BSC control plane.
Measurement
Under MS’s packet idle status, when BSC sends the request for
Point
DL resource to BSC control plane after receiving LLC frame from
SGSN, the counter increments.
The measurement point is as A1, as shown in Figure 76.

82 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

FIGURE 76 –MEASUREMENT POINT OF NUMBER OF GPRS DL TBF


ESTABLISHMENT REQUESTS ON CCCH/PCCCH

Unit Times

C900040145
Definition Number of EGPRS DL TBF establishment requests before T3192
expiration
Description During the running of T3193 of DL EGPRS TBF, BSC receives DL
LLC frame again, then it performs DL assignment on PACCH of
the DL TBF.
This counter counts the number of times of establishing new DL
TBF.
Measurement After the DL EGPRS TBF transmits all LLC frames and the DL RLC
Point block with FBI = 1, T3193 is started. During T3193 running,
when BSC receives new LLC frame and sends DL assignment,
this counter increments.
The measurement point is A, as shown in Figure 77.

Confidential and Proprietary Information of ZTE CORPORATION 83


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 77 –MEASUREMENT POINT OF NUMBER OF EGPRS DL TBF


ESTABLISHMENT REQUESTS BEFORE T3192 EXPIRATION

MS BSC SGSN
LLC Frame
RLC Block
LLC Frame
RLC Block
RLC Block(FBI=1)
Start T3193

LLC Frame
Packet Downlink Assignment
A

Unit Times

C900040146
Definition Number of EGPRS DL TBF establishment using existing DL TBF
resource
Description When establishing EGPRS DL TBF under UL transmission status,
the user plane needs not to request control plane for DL
resource if having saved DL TBF resource of last time. It uses
the existing resource for DL assignment. This counter records
the number of EGPRS DL TBF establishment using existing DL
TBF resource.
Measurement During the UL EGPRS TBF transmission, when BSC receives the
Point DL LLC frame, it uses the existing resource to establish DL GPRS
TBF.
The measurement point is A, as shown in Figure 78.

FIGURE 78 –MEASUREMENT POINT OF NUMBER OF EGPRS DL TBF


ESTABLISHMENT USING EXISTING DL TBF RESOURCE

MS BSC SGSN

RLC Block
RLC Block
LLC Frame
Packet Downlink Assignment
(Packet Timeslot Reconfigure)
A
RLC Block

Unit Times

84 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

C900040147
Definition Number of EGPRS DL TBF establishment requests on PACCH
Description Under UL transmission status, it is necessary to establish DL TBF
transmission when user plane receives DL LLC Frame from SGSN.
If user plane has not saved DL TBF resource, then user plane
requests control plane for resource.
This counter counts the number of times of requesting control
plane for resource to establish EGPRS DL TBF on PACCH.
Measurement The measurement point is A1, as shown in Figure 79.
Point
FIGURE 79 –MEASUREMENT POINT OF NUMBER OF GPRS DL TBF
ESTABLISHM ENT REQUESTS ON P ACCH

MS BSC user plane BSC control plane SGSN

RLC Block
RLC Block
LLC Frame (no record downlink resource)

A1
Downlink Assign Request
Packet Downlink Assignment Resource Assignment
(Packet Timeslot Reconfigure)

A2

Unit Times

C900040148
Definition Number of EGPRS DL TBF establishment requests on
CCCH/PCCCH
Description When MS is in packet idle status, after BSC receives DL LLC
frame from SGSN, BSC initiates the process of establishing DL
TBF which is assigned on CCCH or PCCCH. BSC user plane first
sends the request for DL establishment to BSC control plane.
Measurement Under MS’s packet idle status, when BSC sends the request for
Point DL resource to BSC control plane after receiving LLC frame from
SGSN, the counter increments. The measurement point is A1, as
shown in Figure 80.

Confidential and Proprietary Information of ZTE CORPORATION 85


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 80 – NORM AL CCCH/PCCCH DL TBF ESTABLISHMENT PROCESS

Unit Times

C900040149
Definition Number of GPRS DL signaling TBF release due to N3105
overflow
Description During the GPRS signaling DL TBF transmission, the DL block
RRBP bit is set to ask MS to respond with a Packet Downlink
Ack/Nack message.
If the specified block of BSC fails to receive response from MS,
then the N3105 counter increments; otherwise, it has a clear. If
no response comes from the MS, then the RRBP bit is set again
to ask MS to respond with a Packet Downlink Ack/Nack
message; if the N3105 counter reaches its maximum value, it is
considered that the radio transmission fails and the GPRS
signaling DL TBF is released abnormally.
Measurement When the N3105 counter value exceeds N3105Max, this counter
Point increments. The measurement point is A1, as shown in Figure 81.

86 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

FIGURE 81 – MEASUREMENT POINT OF NUMBER OF GPRS DL SIGNALING


TBF RELEASE DUE TO N3105 OVERFLOW

Unit Times

C900040150
Definition Number of GPRS DL signaling TBF release due to other reasons
Description When BSC is transmitting the last RLC block of GPRS signaling
DL TBF, set FBI to 1, set RRBP to ask the MS to respond with a
Packet Downlink Ack/Nack message, and at the same time,
activate T3191. If the specified block receives the MS response,
then T3191 will stop and the DL transmission ends normally. If
T3191 overflows, then it is considered that the radio
transmission fails and the GPRS signaling DL TBF is released
abnormally.
Measurement The measurement point is A1, as shown in Figure 82.
Point
FIGURE 82 – MEASUREMENT POINT OF NUMBER OF GPRS DL TBF RELEASE
DUE TO OTHER REASONS

MS BSC

RLC Block

Start T3191
DOWNLINK ACK

Normal release

T3191 Timeout
A1

Confidential and Proprietary Information of ZTE CORPORATION 87


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Unit Times

C900040151
Definition Number of GPRS DL signaling TBF forcing release by control
plane
Description When the user plane is transmitting the GPRS signaling DL TBF,
if a release request comes from the control plane, then the GPRS
signaling DL TBF will stop and be released abnormally.
Measurement When the user plane receives the release request from the
Point control plane, this counter increments. The measurement point
is A, as shown in Figure 83.

FIGURE 83 – MEASUREMENT POINT OF NUMBER OF GPRS DL TBF FORCING


RELEASE BY CONTROL PLANE

Unit Times

C900040152
Definition Number of GPRS DL signaling TBF release due to instance
suspension
Description When the user plane is transmitting the GPRS signaling DL TBF,
at least one block must be transmitted in every 5 seconds. After
a DL TBF block is transmitted, BSC will start or restart a 5-
second DL block assigning timer. If the timer expires, it is
considered that the user plane has an instance suspension and
the GPRS signaling DL TBF is released abnormally.
Measurement When the DL block assigning timer expires, this counter
Point increments. The measurement point is A, as shown in Figure 84.

88 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

FIGURE 84 - MEASUREMENT POINT OF NUMBER OF GPRS DL TBF RELEASE


DUE TO INSTANCE SUSPENSION

Unit Times

C900040153
Definition Number of GPRS DL signaling TBF release due to inner abnormal
Description When the user plane is transmitting the GPRS signaling DL TBF,
if the message fails to be sent at the radio interface, the RLC
instance fails to be created, or the resource reassignment fails,
the GPRS signaling DL TBF will be released abnormally.
Measurement During the transmission of GPRS signaling DL TBF, if the
Point message fails to be sent at the radio interface, the RLC instance
fails to be created, or the resource reassignment fails, this
counter increments.
Unit Times

C900040154
Definition Number of EGPRS DL signaling TBF release due to N3105
overflow
Description During the transmission of EGPRS signaling DL TBF, the DL block
RRBP bit is set to ask the MS to respond with a Packet
Downlink Ack/Nack message.
If the specified block of BSC does not receive the MS response,
then the N3105 counter increments; if it does, then it has a
clear; if no response comes from the MS, then the RRBP bit is
set again to ask the MS to respond with a Packet Downlink
Ack/Nack message; if the N3105 counter reaches its maximum

Confidential and Proprietary Information of ZTE CORPORATION 89


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

value, it is considered that the radio transmission fails and the


DL TBF is released abnormally.
Measurement When the N3105 counter value exceeds N3105Max, this counter
Point increments. The measurement point is A1, as shown in Figure 85.

FIGURE 85 – MEASUREMENT POINT OF NUMBER OF EGPRS DL SIGNALING


TBF RELEASE DUE TO N3105 OVERFLOW

Unit Times

C900040155
Definition Number of EGPRS DL signaling TBF release due to other reasons
Description When BSC is transmitting the last RLC block of EGPRS signaling
DL TBF, set FBI to 1, set RRBP to ask the MS to respond with a
Packet Downlink Ack/Nack message, and at the same time,
activate T3191.
If the specified block receives the MS response, then T3191 will
stop and the DL transmission ends normally. If T3191 overflows,
then it is considered that the radio transmission fails and the
EGPRS signaling DL TBF is released abnormally.
Measurement The measurement point is A1, as shown in Figure 86.
Point

90 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

FIGURE 86 – MEASUREMENT POINT OF NUMBER OF EGPRS DL TBF RELEASE


DUE TO OTHER REASONS

Unit Times

C900040156
Definition Number of EGPRS DL signaling TBF forcing release by control
plane
Description When the user plane is transmitting the EGPRS signaling DL TBF,
if a release request comes from the control plane, then the
EGPRS signaling DL TBF will stop and be released abnormally.
Measurement When the user plane receives the release request from the
Point control plane, this counter increments. The measurement point
is A, as shown in Figure 87.

FIGURE 87 – MEASUREMENT POINT OF NUMBER OF EGPRS DL TBF FORCING


RELEASE BY CONTROL PLANE

Unit Times

C900040157
Definition Number of EGPRS DL signaling TBF release due to instance
suspension

Confidential and Proprietary Information of ZTE CORPORATION 91


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Description When the user plane is transmitting the EGPRS signaling DL TBF,
at least one block must be transmitted in every 5 seconds. After
a DL TBF block is transmitted, BSC will start or restart a 5-
second DL block assigning timer. If the timer expires, it is
considered that the user plane has an instance suspension and
the EGPRS signaling DL TBF is released abnormally.
Measurement When the DL block assigning timer expires, this counter
Point increments. The measurement point is A1, as shown in Figure 88.

FIGURE 88 - MEASUREMENT POINT OF NUMBER OF NUMBER OF EGPRS DL


TBF RELEASE DUE TO INSTANCE SUSPENSION

Unit Times

C900040158
Definition Number of EGPRS DL signaling TBF release due to inner
abnormal
Description When the user plane is transmitting the EGPRS signaling DL TBF,
if the message fails to be sent at the radio interface, the RLC
instance fails to be created, or the resource reassignment fails,
the EGPRS signaling DL TBF will be released abnormally.
Measurement During the transmission of EGPRS signaling DL TBF, if the
Point message fails to be sent at the radio interface, the RLC instance
fails to be created, or the resource reassignment fails, this
counter increments.
Unit Times

C900040159
Definition Number of GPRS UL TBF establishments in release state

92 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Description If both MS and BSS support reestablishment in released state,


BSS sets RRBP and sends Packet UL Ack message (FAI =1 and
TBF Est = 1) to MS after receiving all RLC blocks from MS.
If MS has no new data to send, MS returns Packet Ctrl Ack
message to BSS.
If MS has new data to send but no DL TBF is available, then TBF
should be reestablished, with the following two cases to be
considered:
„ If system message indicates that Packet Control Ack is of
AB mode, then MS sends Packet Control Ack message
(Ctrl Ack bit is ‘00’) to BSS, and BSS specifies single block
resource for MS by Packet UL Assign message. Subsequent
flow is same as that of TWO STEP access.
„ If system message indicates that Packet Control Ack is of
RLC/MAC mode, then MS sends Packet Resource Request
message to BSS. Subsequent flow is same as that of TWO
STEP access.
Usage This counter records the number of reestablishment times of MS
in released state.
Measurement The measurement is A, as shown in Figure 89 and Figure 90.
Point
FIGURE 89 – MEASUREMENT POINT ON NUMBER OF GPRS UL TBF
REESTABLISHMENTS IN RELEASED STATE (1)

FIGURE 90 - MEASUREMENT POINT ON NUMBER OF GPRS UL TBF


REESTABLISHMENTS IN RELEASED STATE (2)

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 93


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040160
Definition Number of GPRS UL TBF establishment with existing UL resource
Description To accelerate TBF establishment, UPPB caches MS’s UL/DL
resource within a period of time. When MS attempts to establish
new UL TBF on PACCH, relevant resource is directly assigned to
MS if there is resource as indicated by UPPB; otherwise, MS
sends request for resource to CMP.
Usage This counter records the number of reestablishing UL GPRS TBF
in released state without having to request for resource.
Measurement The measurement is A, as shown in Figure 91.
Point
FIGURE 91 - MEASUREMENT POINT OF GPRS UL TBF ESTABLISHMENTS WITH
EXISTING UL RESOURCE

Unit Times

C900040161
Definition Number of GPRS UL TBF establishment requests on PACCH
Description When MS has DL TBF and the TBF is in transmission status, if
MS has UL data to send but no UL TBF is available, MS sends
Packet DL Ack message together with UL TBF establishment
request. This counter counts the number of resource re-
applications after receiving this request.
Usage This counter records the number of requests for establishing UL
GPRS TBF on PACCH.
Measurement The measurement is A, as shown in Figure 92.
Point

94 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

FIGURE 92 – MEASUREMENT POINT OF NUMBER OF REQUESTS FOR


ESTABLISHING UL GPRS TBF ON P ACCH

Unit Times

C900040162
Definition Number of EGPRS UL data TBF establishments on PACCH
Description When there is available DL TBF, MS sends Packet DL Ack
message with UL TBF establishment request. When there is a
request to establish UL TBF on PACCH and the TBF type is
EGPRS, the counter increments.
Usage This counter records the number of times of establishing EGPRS
UL TBF on PACCH.
Measurement When Packet DL Ack message with UL TBF establishment
Point request is received, and the TBF type is EGPRS, the counter
increments.
Unit Times

C900040163
Definition Number of EGPRS UL TBF establishments in release state
Description If both MS and BSS support reestablishment in released state,
BSS sets RRBP and sends Packet UL Ack message (FAI =1 and
TBF Est = 1) to MS after receiving all RLC blocks from MS.
If MS has no new data to send, MS returns Packet Ctrl Ack
message to BSS.
If MS has new data to send but no DL TBF is available, then TBF
should be reestablished, with the following two cases to be
considered:
„ If system message indicates that Packet Control Ack is of
AB mode, then MS sends Packet Control Ack message
(Ctrl Ack bit is ‘00’) to BSS, and BSS specifies single block
resource for MS by Packet UL Assign message. Subsequent
flow is same as that of TWO STEP access.

Confidential and Proprietary Information of ZTE CORPORATION 95


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

„ If system message indicates that Packet Control Ack is of


RLC/MAC mode, then MS sends Packet Resource Request
message to BSS. Subsequent flow is same as that of TWO
STEP access.
Usage This counter records the number of reestablishment times of MS
in released state.
Measurement The measurement is A, as shown in Figure 93 and Figure 94.
Point
FIGURE 93 – MEASUREMENT POINT ON NUMBER OF EGPRS UL TBF
REESTABLISHMENTS IN RELEASED STATE (1)

FIGURE 94 - MEASUREMENT POINT ON NUMBER OF EGPRS UL TBF


REESTABLISHMENTS IN RELEASED STATE (2)

Unit Times

C900040164
Definition Number of EGPRS UL TBF establishment with existing UL
resource
Description To accelerate TBF establishment, UPPB caches MS’s UL/DL
resource within a period of time. When MS attempts to establish
new UL TBF on PACCH, relevant resource is directly assigned to
MS if there is resource as indicated by UPPB; otherwise, MS
sends request for resource to CMP.
Usage This counter records the number of reestablishing UL EGPRS TBF
in released state without having to request for resource.
Measurement The measurement is A, as shown in Figure 95.
Point

96 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

FIGURE 95 - MEASUREMENT POINT OF EGPRS UL TBF ESTABLISHMENTS


WITH EXISTING UL RESOURCE

Unit Times

C900040165
Definition Number of EGPRS UL TBF establishment requests on PACCH
Description When MS has DL TBF and the TBF is in transmission status, if
MS has UL data to send but no UL TBF is available, MS sends
Packet DL Ack message together with UL TBF establishment
request. This counter counts the number of resource re-
applications after receiving this request.
Usage This counter records the number of requests for establishing UL
EGPRS TBF on PACCH.
Measurement The measurement is A, as shown in Figure 96.
Point
FIGURE 96 – MEASUREMENT POINT OF NUMBER OF REQUESTS FOR
ESTABLISHING UL EGPRS TBF ON P ACCH

Unit Times

C900040166
Definition Number of EGPRS UL TBF establishment requests on
CCCH/PCCCH
Description When MS has new data to transmit but no corresponding UL/DL
TBF is available, MS initiates UL TBF establishment flow,

Confidential and Proprietary Information of ZTE CORPORATION 97


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

depending on whether the cell configures PBCCH on


CCCH/PCCCH.
Usage This counter records the number of requests for establishing
EGPRS UL TBF on CCCH/PCCCH.
Measurement The measurement point is A, as shown in Figure 97.
Point
FIGURE 97 – MEASUREMENT POINT OF NUMBER OF EGPRS UL TBF
ESTABLISHMENT REQUESTS ON CCCH/PCCCH

Unit Times

C900040167
Definition Number of dynamic PDCH preemption for CS service
Description This counter counts the number of times of PDCH being
preempted when the service instance is performing CS service
but fails to request for the radio channel.
Usage This counter is used to find out the busy extent of PS service
and CS service in the current cell. It can be used as reference
for expanding radio channel configuration, so as to meet
requirements of both CS and PS services.
Measurement The counter increments when the following conditions are
Point satisfied:
„ When the service instance is performing CS service but fails
to request for the radio channel
„ The database initiates the dynamic PDCH collection
Unit Times

C900040168
Definition Number of GPRS UL TBF establishment requests on
CCCH/PCCCH
Description When MS has new data to transmit but no corresponding UL/DL
TBF is available, MS initiates UL TBF establishment flow,
depending on whether the cell configures PBCCH on
CCCH/PCCCH.
Usage This counter records the number of requests for establishing
GPRS UL TBF on CCCH/PCCCH.

98 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Measurement The measurement point is A, as shown in Figure 98.


Point
FIGURE 98 - MEASUREMENT POINT OF NUMBER OF GPRS UL TBF
ESTABLISHMENT REQUESTS ON CCCH/PCCCH

Unit Times

C900040169
Definition Number of GPRS DL TBF establishment requests on PACCH
Description When UL TBF exists, and there is DL data to be sent through
SGSN, a request will be sent to establish DL TBF on PACCH. This
counter increments upon the request and the TBF type is GPRS.
Usage This counter counts the number of requests to establish GPRS
DL TBF on PACCH.
Measurement When a request is sent to establish DL TBF on PACCH and the
Point TBF type is GPRS, this counter increments.
Unit Times

C900040170
Definition Number of EGPRS DL TBF establishment requests on PACCH
Description When UL TBF exists, and there is DL data to be sent through
SGSN, a request will be sent to establish DL TBF on PACCH. This
counter increments upon the request and the TBF type is EGPRS.
Usage This counter counts the number of requests to establish EGPRS
DL TBF on PACCH.
Measurement When a request is sent to establish DL TBF on PACCH and the
Point TBF type is EGPRS, this counter increments.
Unit Times

C900040171
Definition Number of GPRS UL TBF establishment requests on PACCH
Description When there is available DL TBF, MS sends Packet DL Ack
message with UL TBF establishment request. When there is a

Confidential and Proprietary Information of ZTE CORPORATION 99


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

request to establish UL TBF on PACCH and the TBF type is GPRS,


the counter increments.
Usage This counter records the number of requests to establish GPRS
UL TBF on PACCH.
Measurement When Packet DL Ack message with UL TBF establishment
Point request is received, and the TBF type is GPRS, this counter
increments.
Unit Times

C900040172
Definition Number of DL RLC pending blocks in MCS1 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL pending RLC
blocks from BSC to MS, with coding method of MCS1.
Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of MCS1.
Measurement When BSC sends a pending RLC block whose coding method is
Point MCS1 to MS, the counter increments. The measurement point is
A, as shown in Figure 53.
Unit Times

C900040173
Definition Number of DL RLC pending blocks in MCS2 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL pending RLC
blocks from BSC to MS, with coding method of MCS2.
Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of MCS2.
Measurement When BSC sends a pending RLC block whose coding method is
Point MCS2 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 53.
Unit Times

C900040174
Definition Number of DL RLC pending blocks in MCS3 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new

100 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

data blocks. This counter counts the number of DL pending RLC


blocks from BSC to MS, with coding method of MCS3.
Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of MCS3.

Measurement When BSC sends a pending RLC block whose coding method is
Point MCS3 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 53.
Unit Times

C900040175
Definition Number of DL RLC pending blocks in MCS4 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL pending RLC
blocks from BSC to MS, with coding method of MCS4.
Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of MCS4.
Measurement When BSC sends a pending RLC block whose coding method is
Point MCS4 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 53.
Unit Times

C900040176
Definition Number of DL RLC pending blocks in MCS5 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL pending RLC
blocks from BSC to MS, with coding method of MCS5.
Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of MCS5.
Measurement When BSC sends a pending RLC block whose coding method is
Point MCS5 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 53.
Unit Times

C900040177
Definition Number of DL RLC pending blocks in MCS6 on PDTCH

Confidential and Proprietary Information of ZTE CORPORATION 101


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Description After BSC receives DownLink Ack message, it decides whether


to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL pending RLC
blocks from BSC to MS, with coding method of MCS6.
Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of MCS6.
Measurement When BSC sends a pending RLC block whose coding method is
Point MCS6 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 53.
Unit Times

C900040178
Definition Number of DL RLC pending blocks in MCS7 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL pending RLC
blocks from BSC to MS, with coding method of MCS7.
Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of MCS7.
Measurement When BSC sends a pending RLC block whose coding method is
Point MCS7 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 53.
Unit Times

C900040179
Definition Number of DL RLC pending blocks in MCS8 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL pending RLC
blocks from BSC to MS, with coding method of MCS8.
Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of MCS8.
Measurement When BSC sends a pending RLC block whose coding method is
Point MCS8 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 53.
Unit Times

C900040180
Definition Number of DL RLC pending blocks in MCS9 on PDTCH

102 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Description After BSC receives DownLink Ack message, it decides whether


to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL pending RLC
blocks from BSC to MS, with coding method of MCS9.
Usage This counter counts the number of DL pending RLC blocks sent
on PDTCH, with coding method of MCS9.
Measurement When BSC sends a pending RLC block whose coding method is
Point MCS9 to MS via BTS, the counter increments. The measurement
point is A, as shown in Figure 53.
Unit Times

C900040181
Definition Number of DL RLC NACK blocks in MCS1 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of MCS1.
Usage This counter counts the number of DL retransmitted RLC blocks
sent on PDTCH, with coding method of MCS1.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is MCS1 to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 54.
Unit Times

C900040182
Definition Number of DL RLC NACK blocks in MCS2 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of MCS2.
Usage This counter counts the number of DL retransmitted RLC blocks
sent on PDTCH, with coding method of MCS2.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is MCS2 to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 54.
Unit Times

C900040183
Definition Number of DL RLC NACK blocks in MCS3 on PDTCH

Confidential and Proprietary Information of ZTE CORPORATION 103


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Description After BSC receives DownLink Ack message, it decides whether


to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of MCS3.
Usage This counter counts the number of DL retransmitted RLC blocks
sent on PDTCH, with coding method of MCS3.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is MCS3 to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 54.
Unit Times

C900040184
Definition Number of DL RLC NACK blocks in MCS4 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of MCS4.
Usage This counter counts the number of DL retransmitted RLC blocks
sent on PDTCH, with coding method of MCS4.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is MCS4 to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 54.
Unit Times

C900040185
Definition Number of DL RLC NACK blocks in MCS5 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of MCS5.
Usage This counter counts the number of DL retransmitted RLC blocks
sent on PDTCH, with coding method of MCS5.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is MCS5 to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 54.
Unit Times

C900040186
Definition Number of DL RLC NACK blocks in MCS6 on PDTCH

104 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Description After BSC receives DownLink Ack message, it decides whether


to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of MCS6.
Usage This counter counts the number of DL retransmitted RLC blocks
sent on PDTCH, with coding method of MCS6.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is MCS6 to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 54.
Unit Times

C900040187
Definition Number of DL RLC NACK blocks in MCS7 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of MCS7.
Usage This counter counts the number of DL retransmitted RLC blocks
sent on PDTCH, with coding method of MCS7.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is MCS7 to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 54.
Unit Times

C900040188
Definition Number of DL RLC NACK blocks in MCS8 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of MCS8.
Usage This counter counts the number of DL retransmitted RLC blocks
sent on PDTCH, with coding method of MCS8.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is MCS8 to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 54.
Unit Times

C900040189
Definition Number of DL RLC NACK blocks in MCS9 on PDTCH

Confidential and Proprietary Information of ZTE CORPORATION 105


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Description After BSC receives DownLink Ack message, it decides whether


to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL retransmitted
RLC blocks from BSC to MS, with coding method of MCS9.
Usage This counter counts the number of DL retransmitted RLC blocks
sent on PDTCH, with coding method of MCS9.
Measurement When BSC sends retransmitted RLC block whose coding method
Point is MCS9 to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 54.
Unit Times

C900040190
Definition Number of DL RLC new blocks in MCS1 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
MCS1.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of MCS1
Measurement When BSC sends first-transmitted RLC block (with coding
Point method of MCS1) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.
Unit Times

C900040191
Definition Number of DL RLC new blocks in MCS2 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
MCS2.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of MCS2.
Measurement When BSC sends first-transmitted RLC block (with coding
Point method of MCS2) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.
Unit Times

106 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

C900040192
Definition Number of DL RLC new blocks in MCS3 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
MCS3.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of MCS3.
Measurement When BSC sends first-transmitted RLC block (with coding
Point method of MCS3) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.
Unit Times

C900040193
Definition Number of DL RLC new blocks in MCS4 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
MCS4.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of MCS4.
Measurement When BSC sends first-transmitted RLC block (with coding
Point method of MCS4) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.
Unit Times

C900040194
Definition Number of DL RLC new blocks in MCS5 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
MCS5.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of MCS5.
Measurement When BSC sends first-transmitted RLC block (with coding
Point method of MCS5) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.

Confidential and Proprietary Information of ZTE CORPORATION 107


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Unit Times

C900040195
Definition Number of DL RLC new blocks in MCS6 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
MCS6.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of MCS6.
Measurement When BSC sends first-transmitted RLC block (with coding
Point method of MCS6) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.
Unit Times

C900040196
Definition Number of DL RLC new blocks in MCS7 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
MCS7.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of MCS7.
Measurement When BSC sends first-transmitted RLC block (with coding
Point method of MCS7) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.
Unit Times

C900040197
Definition Number of DL RLC new blocks in MCS8 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
MCS8.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of MCS8.

108 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Measurement When BSC sends first-transmitted RLC block (with coding


Point method of MCS8) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.
Unit Times

C900040198
Definition Number of DL RLC new blocks in MCS9 on PDTCH
Description After BSC receives DownLink Ack message, it decides whether
to send pending RLC block, to resend RLC block or to send new
data blocks. This counter counts the number of DL first-
transmitted RLC blocks from BSC to MS, with coding method of
MCS9.
Usage The counter is used to review the status of DL first-transmitted
RLC blocks sent by BSC on PDTCH, with coding method of MCS9.
Measurement When BSC sends first-transmitted RLC block (with coding
Point method of MCS9) to MS via BTS, the counter increments. The
measurement point is A, as shown in Figure 55.
Unit Times

C900040199
Definition Number of UL RLC pending blocks in MCS1 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS1-
coded pending RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS1-coded
pending RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS1-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.
Unit Times

C900040200
Definition Number of UL RLC pending blocks in MCS2 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS2-
coded pending RLC blocks received on PDTCH.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 109


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

This counter counts the number of useful UL MCS2-coded


pending RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS2-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.
Unit Times

C900040201
Definition Number of UL RLC pending blocks in MCS3 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS3-
coded pending RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS3-coded
pending RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS3-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.
Unit Times

C900040202
Definition Number of UL RLC pending blocks in MCS4 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS4-
coded pending RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS4-coded
pending RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS4-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.
Unit Times

C900040203
Definition Number of UL RLC pending blocks in MCS5 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS5-
coded pending RLC blocks received on PDTCH.

110 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Usage This counter counts the number of useful UL MCS5-coded


pending RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS5-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.
Unit Times

C900040204
Definition Number of UL RLC pending blocks in MCS6 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS6-
coded pending RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS6-coded
pending RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS6-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.
Unit Times

C900040205
Definition Number of UL RLC pending blocks in MCS7 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS7-
coded pending RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS7-coded
pending RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS7-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.
Unit Times

C900040206
Definition Number of UL RLC pending blocks in MCS8 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS8-
coded pending RLC blocks received on PDTCH.

Confidential and Proprietary Information of ZTE CORPORATION 111


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Usage This counter counts the number of useful UL MCS8-coded


pending RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS8-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.
Unit Times

C900040207
Definition Number of UL RLC pending blocks in MCS9 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS9-
coded pending RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS9-coded
pending RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS9-coded UL pending RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 57.
Unit Times

C900040208
Definition Number of UL RLC NACK blocks in MCS1 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS1-
coded retransmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS1-coded
retransmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS1-coded UL retransmitted RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C900040209
Definition Number of UL RLC NACK blocks in MCS2 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS2-
coded retransmitted RLC blocks received on PDTCH.

112 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

Usage This counter counts the number of useful UL MCS2-coded


retransmitted RLC blocks received by BSC on PDTCH.

Measurement When BSC receives MCS2-coded UL retransmitted RLC block, the


Point counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C900040210
Definition Number of UL RLC NACK blocks in MCS3 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS3-
coded retransmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS3-coded
retransmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS3-coded UL retransmitted RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C900040211
Definition Number of UL RLC NACK blocks in MCS4 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS4-
coded retransmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS4-coded
retransmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS4-coded UL retransmitted RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C900040212
Definition Number of UL RLC NACK blocks in MCS5 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending

Confidential and Proprietary Information of ZTE CORPORATION 113


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

RLC block. This counter counts the number of useful UL MCS5-


coded retransmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS5-coded
retransmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS5-coded UL retransmitted RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C900040213
Definition Number of UL RLC NACK blocks in MCS6 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS6-
coded retransmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS6-coded
retransmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS6-coded UL retransmitted RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C900040214
Definition Number of UL RLC NACK blocks in MCS7 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS7-
coded retransmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS7-coded
retransmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS7-coded UL retransmitted RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C900040215
Definition Number of UL RLC NACK blocks in MCS8 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending

114 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

RLC block. This counter counts the number of useful UL MCS8-


coded retransmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS8-coded
retransmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS8-coded UL retransmitted RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C900040216
Definition Number of UL RLC NACK blocks in MCS9 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS9-
coded retransmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS9-coded
retransmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS9-coded UL retransmitted RLC block, the
Point counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C900040217
Definition Number of UL RLC new blocks in MCS1 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS1-
coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS1-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS1-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.
Unit Times

C900040218
Definition Number of UL RLC new blocks in MCS2 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending

Confidential and Proprietary Information of ZTE CORPORATION 115


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

RLC block. This counter counts the number of useful UL MCS2-


coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS2-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS2-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.
Unit Times

C900040219
Definition Number of UL RLC new blocks in MCS3 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS3-
coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS3-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS3-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.
Unit Times

C900040220
Definition Number of UL RLC new blocks in MCS4 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS4-
coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS4-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS4-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.
Unit Times

C900040221
Definition Number of UL RLC new blocks in MCS5 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending

116 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - PS Basic Measurement (Cell)

RLC block. This counter counts the number of useful UL MCS5-


coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS5-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS5-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.
Unit Times

C900040222
Definition Number of UL RLC new blocks in MCS6 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS6-
coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS6-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS6-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.
Unit Times

C900040223
Definition Number of UL RLC new blocks in MCS7 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS7-
coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS7-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS7-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.
Unit Times

C900040224
Definition Number of UL RLC new blocks in MCS8 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending

Confidential and Proprietary Information of ZTE CORPORATION 117


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

RLC block. This counter counts the number of useful UL MCS8-


coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS8-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS8-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.
Unit Times

C900040225
Definition Number of UL RLC new blocks in MCS9 on PDTCH
Description After receiving UL data block, BSC decides whether it is
retransmitted RLC block, first-transmitted RLC block or pending
RLC block. This counter counts the number of useful UL MCS9-
coded first-transmitted RLC blocks received on PDTCH.
Usage This counter counts the number of useful UL MCS9-coded first-
transmitted RLC blocks received by BSC on PDTCH.
Measurement When BSC receives MCS9-coded UL first-transmitted RLC block,
Point the counter increments. The measurement point is A, as shown
in Figure 59.
Unit Times

118 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3

CPU Load Measurement

CPU load measurement aims to make a statistic of the


performance related with circuit switching service on BSC level.
This chapter describes the definition, usage and measurement
point of various counters.

Overview
CPU load measurement consists of statistic of the average value
and peak value of CPU load.
The measurement takes BSC as the statistics unit.

CPU Load Measurement Counter


Index
Table 7 lists counters related to CPU load measurement.

TABLE 7 – CPU LOAD MEASUREMENT COUNTERS

Counter ID What It Counts


C900050001 Average load of the processor
C900050002 Peak value of the processor load

C900050001
Definition Average load of the processor
Description This counter counts the average load of the main processor
during measurement period.

Confidential and Proprietary Information of ZTE CORPORATION 119


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Measurement After a collection period ends, calculation will be executed


Point according to the sampling load of the main processor.
Unit Percent

C900050002
Definition Peak value of the processor load
Description This counter counts the peak value of the main processor load
during measurement period.
Measurement The measurement point is the peak value of the sampling main
Point processor load during collection period.
Unit Percent

120 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4

CS Basic Measurement

This chapter contains detailed information about counters


related to CS basic measurement.

Overview
CS basic measurement involves counters that are used to
evaluate the circuit switching service performance and status.
These counters are often used in measurement related to radio
access, SDCCH, TCH, SAPI3, call drop, handover, Abis interface
message statistics, and radio resource availability.
The measurement takes cell as the statistics unit.

CS Basic Measurement Counter


Index
Table 8 lists counters related to CS basic measurement.

TABLE 8 – CS BASIC MEASUREMENT COUNTERS

Counter ID What It Counts


C900060001 Number of MTC access attempts
C900060002 Number of MTC access success
C900060003 Number of SDCCH seizure attempts for assignment
C900060004 Number of SDCCH seizure success for assignment
C900060005 Number of SDCCH seizure failure for assignment
C900060006 Number of SDCCH seizure attempts for handover
C900060007 Number of SDCCH seizure failure for handover
C900060008 Number of SDCCH allocation success for assignment
C900060009 Number of SDCCH allocation failure for assignment

Confidential and Proprietary Information of ZTE CORPORATION 121


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Counter ID What It Counts


Number of signaling TCH/F seizure attempts for
C900060010
assignment
Number of signaling TCH/F seizure failure for
C900060011
assignment
Number of signaling TCH/F seizure attempts for
C900060012
handover
Number of signaling TCH/F seizure failure for
C900060013
handover
Number of signaling TCH/F allocation success for
C900060014
assignment
Number of signaling TCH/F allocation failure for
C900060015
assignment
Number of signaling TCH/F allocation failure for
C900060016
handover
Number of signaling TCH/F assignment success for
C900060017
assignment
Number of signaling TCH/F assignment failure for
C900060018
assignment
C900060019 Number of voice TCH/F seizure attempts
C900060020 Number of voice TCH/F seizure failure
C900060021 Number of voice TCH/F seizure attempts for handover
C900060022 Number of voice TCH/F seizure failure for handover
Number of TCH/F allocation success for assignment
C900060023
(speech version1)
Number of TCH/F allocation failure for assignment
C900060024
(speech version1)
Number of TCH/F allocation success for assignment
C900060025
(speech version2)
Number of TCH/F allocation success for assignment
C900060026
(speech version3)
Number of TCH/F allocation failure for assignment
C900060027
(speech version3)
C900060028 Number of voice TCH/F assignment success
Number of voice TCH/F assignment failure for
C900060029
assignment
Number of data TCH/F seizure attempts for
C900060030
assignment
C900060031 Number of data TCH/F seizure failure for assignment
C900060032 Number of data TCH/F seizure attempts for handover
C900060033 Number of data TCH/F seizure failure for handover
Number of data TCH/F allocation success for
C900060034
assignment

122 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Counter ID What It Counts


Number of data TCH/F allocation failure for
C900060035
assignment
C900060036 Number of data TCH/F assignment success
C900060037 Number of data TCH/F assignment failure
Number of signaling TCH/H seizure attempts for
C900060038
assignment
Number of signaling TCH/H seizure failure for
C900060039
assignment
Number of signaling TCH/H seizure attempts for
C900060040
handover
Number of signaling TCH/H seizure failure for
C900060041
handover
Number of voice TCH/H seizure attempts for
C900060042
assignment
C900060043 Number of voice TCH/H seizure failure for assignment
Number of voice TCH/H seizure attempts for
C900060044
handover
C900060045 Number of voice TCH/H seizure failure for handover
Number of data TCH/H seizure attempts for
C900060046
assignment
C900060047 Number of data TCH/H seizure failure for assignment
C900060048 Number of data TCH/H seizure attempts for handover
C900060049 Number of data TCH/H seizure failure for handover
Number of SAPI3 link establishment requests on
C900060050
SDCCH (MO-SM)
Number of SAPI3 link establishment requests on
C900060051
SDCCH (MT-SM)
C900060052 Number of SDCCH drops due to handover failure
C900060053 Number of SDCCH drops
C900060054 Number of TCH/F drops
C900060055 Number of TCH/H drops
Average number of idle TCH/F with interference band
C900060056
1
Average number of idle TCH/F with interference band
C900060057
2
Average number of idle TCH/F with interference band
C900060058
3
Average number of idle TCH/F with interference band
C900060059
4
Average number of idle TCH/F with interference band
C900060060
5

Confidential and Proprietary Information of ZTE CORPORATION 123


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Counter ID What It Counts


Average number of idle TCH/H with interference band
C900060061
1
Average number of idle TCH/H with interference band
C900060062
2
Average number of idle TCH/H with interference band
C900060063
3
Average number of idle TCH/H with interference band
C900060064
4
Average number of idle TCH/H with interference band
C900060065
5
C900060066 Number of samples with UL RQ = 0
C900060067 Number of samples with UL RQ = 1
C900060068 Number of samples with UL RQ = 2
C900060069 Number of samples with UL RQ = 3
C900060070 Number of samples with UL RQ = 4
C900060071 Number of samples with UL RQ = 5
C900060072 Number of samples with UL RQ = 6
C900060073 Number of samples with UL RQ = 7
C900060074 Number of samples with DL RQ = 0
C900060075 Number of samples with DL RQ = 1
C900060076 Number of samples with DL RQ = 2
C900060077 Number of samples with DL RQ = 3
C900060078 Number of samples with DL RQ = 4
C900060079 Number of samples with DL RQ = 5
C900060080 Number of samples with DL RQ = 6
C900060081 Number of samples with DL RQ = 7
Number of TCH/F handover attempts due to UL
C900060082
strength
Number of TCH/F handover attempts due to DL
C900060083
strength
Number of TCH/F handover attempts due to UL
C900060084
quality
Number of TCH/F handover attempts due to DL
C900060085
quality
Number of TCH/F handover attempts due to UL
C900060086
interference
Number of TCH/F handover attempts due to DL
C900060087
interference
C900060088 Number of TCH/F handover attempts due to good C/I
C900060089 Number of TCH/F handover attempts due to bad C/I
C900060090 Number of TCH/F handover attempts due to PBGT

124 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Counter ID What It Counts


C900060091 Number of TCH/F handover attempts due to large TA
Number of TCH/F handover attempts due to other
C900060092
reasons
Number of BSC-controlled inter-cell outgoing
C900060093
handover
Number of BSC-controlled inter-cell outgoing
C900060094
handover success
C900060095 Number of MSC-controlled outgoing handover
C900060096 Number of MSC-controlled outgoing handover success
Number of BSC-controlled inter-cell incoming
C900060097
handover
Number of BSC-controlled inter-cell incoming
C900060098
handover success
C900060099 Number of MSC-controlled incoming handover
Number of MSC-controlled incoming handover due to
C900060100
forced release
Number of MSC-controlled incoming handover due to
C900060101
queue
Number of MSC-controlled incoming handover
C900060102
success
Number of incoming handover from undefined layer
C900060103
(GSM900) to current layer(GSM1800)
Number of incoming handover success from
C900060104
undefined layer(GSM900) to current layer (GSM1800)
Number of incoming handover from undefined layer
C900060105
(GSM1800) to current layer (GSM900)
Number of incoming handover success from
C900060106
undefined layer(GSM1800) to current layer(GSM900)
Number of incoming handover from the same layer
C900060107
GSM900 to GSM1800
Number of incoming handover success from the same
C900060108
layer GSM900 to GSM1800
Number of incoming handover from GSM900 to
C900060109
GSM1800 from the upper layer
Number of incoming handover success from GSM900
C900060110
to GSM1800 in the upper layer
Number of incoming handover from GSM900 to
C900060111
GSM1800 in the lower layer
Number of incoming handover success from GSM900
C900060112
to GSM1800 in the lower layer
Number of incoming handover from GSM1800 to
C900060113
GSM900 from the same layer
Number of incoming handover success from GSM1800
C900060114
to GSM900 from the same layer

Confidential and Proprietary Information of ZTE CORPORATION 125


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Counter ID What It Counts


Number of incoming handover from GSM1800 to
C900060115
GSM900 from the upper layer
Number of incoming handover success from GSM1800
C900060116
to GSM900 from the upper layer
Number of incoming handover from GSM1800 to
C900060117
GSM900 from the lower layer
Number of incoming handover success from GSM1800
C900060118
to GSM900 from the lower layer
C900060119 Number of Intra-cell handover
C900060120 Number of Intra-cell handover success
C900060121 Maximum number of busy TCH/H
C900060122 Average number of available SDCCH
C900060123 Average number of unavailable SDCCH
C900060124 SDCCH busy time
C900060125 Average number of available radio channel
C900060126 Average number of unavailable radio channel
C900060127 TCH/H busy time
C900060128 Maximum number of busy TCH/F
C900060129 TCH/F busy time
C900060130 Number of healthy TRXs
C900060131 Number of CM service requests of MOC
Number of SAPI3 link establishment success on
C900060132
SDCCH (MT-SM)
C900060133 Number of available defined SDCCH
C900060134 Number of available defined TCH/F
C900060135 Number of signaling TCH/H assignment failure
C900060136 Number of MOC access attempts
C900060137 Number of wireless access due to paging responses
Number of TCH/F allocation failure due to BTS
C900060138
connection failure for assignment (speech version1)
Number of TCH/F allocation failure due to BIU
C900060139
connection failure for assignment (speech version1)
Number of TCH/F allocation failure due to TCU
C900060140
connection failure for assignment (speech version1)
Number of TCH/F allocation failure due to channel
C900060141
activation failure for assignment (speech version2)
Number of TCH/F allocation failure due to BTS
C900060142
connection failure for assignment (speech version2)
Number of TCH/F allocation failure due to BIU
C900060143
connection failure for assignment (speech version2)

126 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Counter ID What It Counts


Number of TCH/F allocation failure due to TCU
C900060144
connection failure for assignment (speech version2)
Number of TCH/F allocation failure due to BTS
C900060145
connection failure for assignment (speech version3)
Number of TCH/F allocation failure due to BIU
C900060146
connection failure for assignment (speech version3)
Number of TCH/F allocation failure due to TCU
C900060147
connection failure for assignment (speech version3)
Number of TCH/F allocation failure due to BTS
C900060148
connection failure for assignment (speech version3)
Number of data TCH/F allocation failure due to BIU
C900060149
connection failure for assignment
Number of data TCH/F allocation failure due to TCU
C900060150
connection failure for assignment
C900060151 Number of voice TCH/H drops due to handover failure
C900060152 Number of Abis interface paging command messages
C900060153 Number of Abis CS paging messages
C900060154 Number of Abis PS paging messages
C900060155 Number of available defined TCH/H
Number of TCH/F allocation failure due to channel
C900060156
activation failure for handover(speech version1)
Number of TCH/F allocation failure due to BTS
C900060157
connection failure for handover (speech version1)
Number of TCH/F allocation failure due to BIU
C900060158
connection failure for handover (speech version1)
Number of TCH/F allocation failure due to TCU
C900060159
connection failure for handover (speech version1)
Number of TCH/F allocation failure due to channel
C900060160
activation failure for handover(speech version2)
Number of TCH/F allocation failure due to BTS
C900060161
connection failure for handover (speech version2)
Number of TCH/F allocation failure due to BIU
C900060162
connection failure for handover (speech version2)
Number of TCH/F allocation failure due to TCU
C900060163
connection failure for handover (speech version2)
Number of TCH/F allocation failure due to channel
C900060164
activation failure for handover(speech version3)
Number of TCH/F allocation failure due to BTS
C900060165
connection failure for handover (speech version3)
Number of TCH/F allocation failure due to BIU
C900060166
connection failure for handover (speech version3)
Number of TCH/F allocation failure due to TCU
C900060167
connection failure for handover (speech version3)

Confidential and Proprietary Information of ZTE CORPORATION 127


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Counter ID What It Counts


C900060168 Number of Voice TCH/F handover success
Number of data TCH/F allocation failure due to
C900060169
channel activation failure for handover
Number of TCH/F allocation failure due to BTS
C900060170
connection failure for handover
Number of TCH/F allocation failure due to BIU
C900060171
connection failure for handover
Number of TCH/F allocation failure due to TCU
C900060172
connection failure for handover
C900060173 Number of data TCH/F handover success
Number of signaling TCH/H allocation failure for
C900060174
assignment
Number of TCH/H allocation failure due to channel
C900060175
activation failure for assignment (speech version1)
Number of TCH/H allocation failure due to BTS
C900060176
connection failure for assignment (speech version1)
Number of TCH/H allocation failure due to BIU
C900060177
connection failure for assignment (speech version1)
Number of TCH/H allocation failure due to TCU
C900060178
connection failure for assignment (speech version1)
Number of TCH/H allocation failure due to channel
C900060179
activation failure for handover (speech version1)
Number of TCH/H allocation failure due to BTS
C900060180
connection failure for handover (speech version1)
Number of TCH/H allocation failure due to BIU
C900060181
connection failure for handover (speech version1)
Number of TCH/H allocation failure due to TCU
C900060182
connection failure for handover (speech version1)
Number of TCH/H allocation failure due to channel
C900060183
activation failure for assignment (speech version2)
Number of TCH/H allocation failure due to BTS
C900060184
connection failure for assignment (speech version2)
Number of TCH/H allocation failure due to BIU
C900060185
connection failure for assignment (speech version2)
Number of TCH/H allocation failure due to TCU
C900060186
connection failure for assignment (speech version2)
Number of TCH/H allocation failure due to channel
C900060187
activation failure for handover (speech version2)
Number of TCH/H allocation failure due to BTS
C900060188
connection failure for handover (speech version2)
Number of TCH/H allocation failure due to BIU
C900060189
connection failure for handover (speech version2)
Number of TCH/H allocation failure due to TCU
C900060190
connection failure for handover (speech version2)

128 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Counter ID What It Counts


Number of TCH/H allocation failure due to channel
C900060191
activation failure for assignment (speech version3)
Number of TCH/H allocation failure due to BTS
C900060192
connection failure for assignment (speech version3)
Number of TCH/H allocation failure due to BIU
C900060193
connection failure for assignment (speech version3)
Number of TCH/H allocation failure due to TCU
C900060194
connection failure for assignment (speech version3)
Number of TCH/H allocation failure due to channel
C900060195
activation failure for handover (speech version3)
Number of TCH/H allocation failure due to BTS
C900060196
connection failure for handover (speech version3)
Number of TCH/H allocation failure due to BIU
C900060197
connection failure for handover (speech version3)
Number of TCH/H allocation failure due to TCU
C900060198
connection failure for handover (speech version3)
C900060199 Number of Voice TCH/H assignment success
C900060200 Number of Voice TCH/H assignment failure
C900060201 Number of Voice TCH/H handover success
Number of data TCH/H allocation failure due to
C900060202
channel activation failure for assignment
Number of data TCH/H allocation failure due to BTS
C900060203
connection failure for assignment
Number of data TCH/H allocation failure due to BIU
C900060204
connection failure for assignment
Number of data TCH/H allocation failure due to TCU
C900060205
connection failure for assignment
Number of data TCH/H allocation failure due to
C900060206
channel activation failure for handover
Number of data TCH/H allocation failure due to BTS
C900060207
connection failure for handover
Number of data TCH/H allocation failure due to BIU
C900060208
connection failure for handover
Number of data TCH/H allocation failure due to TCU
C900060209
connection failure for handover
C900060210 Number of data TCH/H assignment success
C900060211 Number of data TCH/H assignment failure
C900060212 Number of data TCH/H handover success
Number of BSC-controlled incoming handover due to
C900060213
forced release
Number of BSC-controlled incoming handover due to
C900060214
queues

Confidential and Proprietary Information of ZTE CORPORATION 129


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Counter ID What It Counts


Number of BSC-controlled incoming handover due to
C900060215
forced handover
Number of MSC-controlled incoming handover due to
C900060216
forced handover
C900060217 Number of unavailable defined TCH/H
C900060218 Number of unavailable defined TCH/F
Number of signaling TCH/F drops due to handover
C900060219
failure
C900060220 Number of voice TCH/F drops due to handover failure
C900060221 Number of data TCH/F drops due to handover failure
Number of signaling TCH/H drops due to handover
C900060222
failure
C900060223 Number of data TCH/H drops due to handover failure
Number of TCH/H handover attempts due to UL
C900060224
strength
Number of TCH/H handover attempts due to DL
C900060225
strength
Number of TCH/H handover attempts due to UL
C900060226
quality
Number of TCH/H handover attempts due to DL
C900060227
quality
Number of TCH/H handover attempts due to UL
C900060228
interference
Number of TCH/H handover attempts due to DL
C900060229
interference
C900060230 Number of TCH/H handover attempts due to good C/I
C900060231 Number of TCH/H handover attempts due to bad C/I
C900060232 Number of TCH/H handover attempts due to PBGT
C900060233 Number of TCH/H handover attempts due to large TA
Number of TCH/H handover attempts due to other
C900060234
reasons
C900060235 Number of signaling TCH/H assignment success
C900060236 Number of MOC access success
C900060237 Number of dual band outgoing handover
C900060238 Number of dual band outgoing handover success
C900060239 Number of dual band incoming handover
C900060240 Number of dual band incoming handover success
C900060241 Number of SDCCH assignment attempts
C900060242 Number of SDCCH assignments success
C900060243 Number of SDCCH assignment failure
C900060244 Number of voice TCH/F drops due to radio link failure

130 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Counter ID What It Counts


C900060245 Number of voice TCH/H drops due to radio link failure

C900060001
Definition Number of MTC access attempts
Description This counter counts the number of channel requests due to MTC
random access. When MS sends the CHL_REQ message to BSC
through BTS to request for radio channel, if TA does not exceed
the cell range and the access reason is “MTC”, the counter
increments.
Usage This counter is used to find out the frequency of channel request
due to MTC.
Measurement The counter counts when MS requests for channel from BSC and
Point TA does not exceed the cell range. The measurement point is A1,
as shown in Figure 99.

FIGURE 99 – RADIO ACCESS FLOW

MS BTS BSC
CHL_REQ
CHL_RQD

A1

A2
CHL_ACT

CHL_ACT_ACK

A3

IMM_ASS_ CMD
IMM_ASS
SABM
EST_IND

A4

Unit Times

C900060002
Definition Number of MTC access success
Description This counter counts the number of MS successfully accessing the
channel assigned in the immediate assignment message (the

Confidential and Proprietary Information of ZTE CORPORATION 131


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

access reason is due to MTC). The counter increments when the


following two conditions are satisfied:
„ MS receives the IMM_ASS message from BSC and
successfully accesses the channel.
„ BSC receives the EST_IND message from MS.
Usage This counter is used to find out the frequency of MS access
success due to MTC.
Measurement This counter counts when BSC receives the EST_IND message.
Point The measurement point is A4, as shown in Figure 99.
Unit Times

C900060003
Definition Number of SDCCH seizure attempts for assignment
Description SDCCH channel allocation attempt is activated by the MS
channel request message CHL_REQ. After BSC receives this
message, it attempts to allocate channel for the request.
„ If allocation and occupation succeed, C900060003 and
C900060004 accumulate simultaneously.
„ If occupation fails and the failure is due to transceiver fault,
C900060003, C900060004, and C900060005 do not change.
„ For failures in other cases, C900060003 and C900060005
accumulate simultaneously.
Usage This counter counts the number of SDCCH channel occupation
attempts during assignment, including the number of occupation
success (C900060004) and the number of occupation failure
(C900060005).
Measurement This counter counts when BSC completes requesting for channel
Point (due to assignment) (C900060004 + C900060005). The
measurement point is A1, as shown in Figure 100.

132 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

FIGURE 100 – IMMEDIATE ASSIGNMENT FLOW

MS BTS BSC
CHL_REQ
CHL_RQD

A1

CHL_ACT

CHL_ACT_ACK

IMM _ASS _CMD

A2
IMM_ASS
SABM
EST_IND

A3

Unit Times

C900060004
Definition Number of SDCCH seizure success for assignment
Description SDCCH channel allocation attempt is activated by the MS
channel request message CHL_REQ. After BSC receives this
message, it attempts to allocate channel for the request. This
counter accumulates when allocation and occupation succeed.
Usage This counter counts the number of successful SDCCH channel
occupations during assignment.
Measurement This counter counts when BSC requests for channel (due to
Point assignment) and occupies the channel successfully. The
measurement point is A1, as shown in Figure 100.
Unit Times

C900060005
Definition Number of SDCCH seizure failure for assignment
Description SDCCH channel allocation attempt is activated by the MS
channel request message CHL_REQ. After BSC receives this
message, it attempts to allocate channel for the request.
„ If allocation succeeds but occupation fails, this counter
accumulates.

Confidential and Proprietary Information of ZTE CORPORATION 133


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

„ If the request returns that the transceiver is faulty, this


counter does not change.
„ For failures in other cases, this counter accumulates.
Usage This counter counts the number of SDCCH channel occupation
failures during assignment.
Measurement This counter counts when BSC requests for channel (due to
Point assignment) but fails to occupy the channel. The measurement
point is A1, as shown in Figure 100.
Unit Times

C900060006
Definition Number of SDCCH seizure attempts for handover
Description SDCCH channel allocation attempt is activated by the channel
request message RADIO_APPLY from other channel instances.
After BSC receives this message, it attempts to allocate channel
for the request.
„ If allocation and occupation succeed, C900060006 and
C901250005 accumulate simultaneously.
„ If occupation fails, C900060006 and C900060007
accumulate simultaneously.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource.
f If the waiting for resource succeeds, C900060006 and
C901250005 accumulate simultaneously.
f If the waiting for resource fails and the failure is due to
transceiver fault, C900060006, C901250005, and
C900060007 do not change.
„ For failures in other cases, C900060006 and C900060007
accumulate simultaneously.
Usage This counter counts the number of SDCCH channel occupation
attempts during handover, including the number of occupation
success (C900060006) and the number of occupation failure
(C900060007).
Measurement BSC completes requesting for channel (due to handover), or BSC
Point receives the internal message of waiting for resource
successfully or waiting for resource failed (C901250005 +
C900060007). The measurement point is B1 as shown in Figure
101 and C1 as shown in Figure 102.

134 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

FIGURE 101 – INTERNAL HANDOVER FLOW (INTRA-CELL HANDOVER)

MS BTS BSC MSC


MEAS_REP
MEAS_RES
B1

CHL_ACT
CHL_ACT_ACK

ASS_CMD B2
ASS_CMD
SABM

UA EST_IND
ASS_COM
ASS_COM

B3 HO_PREFORM

FIGURE 102 – EXTERNAL HANDOVER FLOW

MS BTS BSC MSC


HO_REQ

C1

CHL_ACT
CHL_ACT_ACK
C2 HO_REQ_ACK
HO_ACCESS
HO_DETECT
PHY_INFO
HO_DETECT
SABM
UA
HO_COM
HO_COM

C3 HO_COM

Unit Times

C900060007
Definition Number of SDCCH seizure failure for handover
Description SDCCH channel allocation attempt is activated by the channel
request message RADIO_APPLY from other channel instances.
After BSC receives this message, it attempts to allocate channel
for the request.

Confidential and Proprietary Information of ZTE CORPORATION 135


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

„ If occupation fails, this counter accumulates.


„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource. If the waiting for resource fails, this counter
accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.
Usage This counter counts the number of SDCCH occupation failure.
Measurement BSC requests for channel (due to handover) but fails to occupy
Point the channel, or BSC fails to wait for internal resource. The
measurement point is B1 as shown in Figure 101 and C1 as
shown in Figure 102.
Unit Times

C900060008
Definition Number of SDCCH allocation success for assignment
Description After BSC responds the channel request message to allocate and
occupy SDCCH channel successfully, BSC sends the CHL_ACT
message to BTS to activate this SDCCH. If the SDCCH is
activated successfully (that is, when BSC receives the
CHL_ACT_ACK message from BTS), this counter accumulates.
Usage This counter counts the number of successful SDCCH channel
allocations during assignment.
Measurement This counter counts when BSC receives the CHL_ACT_ACK
Point message from BTS and the cause is assignment. The
measurement point is A2, as shown in Figure 100.
Unit Times

C900060009
Definition Number of SDCCH allocation failure for assignment
Description After BSC responds the channel request message to allocate and
occupy SDCCH channel successfully, BSC sends the CHL_ACT
message to BTS to activate this SDCCH. If channel activation
fails due to receiving channel activation failure message,
incorrect channel activation response message, T9103 being
timeout, channel instance being released or channel being
forcibly released, this counter accumulates.
Usage This counter counts the number of SDCCH channel allocation
failure during assignment.

136 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Measurement BSC activates SDCCH channel due to assignment, but receives


Point channel activation failure message, incorrect channel activation
response message, T9103 being timeout, channel instance being
released, or channel being forcibly released. The measurement
point is A2, as shown in Figure 100.
Unit Times

C900060010
Definition Number of signaling TCH/F seizure attempts for assignment
Description This counter counts the number of TCH/F channel occupation
attempts during assigning signaling channels, including the
number of occupation success (C901260002) and the number of
occupation failure (C900060011).
Usage After BSC receives the channel request, it attempts to allocate
channel for the request.
„ If allocation and occupation succeed, C900060010 and
C901260002 accumulate simultaneously.
„ If the request returns that the transceiver is faulty,
C900060010, C901260002, and C900060011 do not change.
„ For other cases, C900060010 and C900060011 accumulate
simultaneously.
Measurement This counter counts when BSC completes requesting for channel
Point (due to assignment and the channel is used as signaling channel)
(C901260002 + C900060011). The measurement point is A1, as
shown in Figure 103.

FIGURE 103 – IMMEDIATE ASSIGNMENT FLOW

MS BTS BSC
CHL_REQ
CHL_RQD
A1
CHL_ACT

CHL_ACT_ACK
A2
IMM_ASS_CMD
IMM_ASS

SABM EST_IND

A3

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 137


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060011
Definition Number of signaling TCH/F seizure failure for assignment
Description This counter counts the number of TCH/F channel occupation
failures during assigning signaling channels.
After BSC receives the channel request, it attempts to allocate
channel for the request.
„ If occupation fails, this counter accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.
Measurement BSC requests for channel (due to assignment and the channel is
Point used as signaling channel) but fails to occupy the channel, or
BSC fails to wait for internal resource. The measurement point is
A1, as shown in Figure 104.

FIGURE 104 – IMMEDIATE ASSIGNMENT OCCUPATION FAILURE FLOW 1

Unit Times

C900060012
Definition Number of signaling TCH/F seizure attempts for handover
Description This counter counts the number of TCH/F channel occupation
attempts during signaling channel handover, including the
number of occupation success (C901260005) and the number of
occupation failure (C900060013).
After BSC receives the channel request, it attempts to allocate
channel for the request.
„ If allocation and occupation succeed, C900060012 and
C901260005 accumulate simultaneously.
„ If occupation fails, C900060012 and C900060013
accumulate simultaneously.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource.

138 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

f If the waiting for resource succeeds, C900060012 and


C901260005 accumulate simultaneously.
f If the waiting for resource fails, C900060012 and
C900060013 accumulate simultaneously.
„ If the request returns that the transceiver is faulty,
C900060012, C901260005, and C900060013 do not change.
„ For failures in other cases, C900060012 and C900060013
accumulate simultaneously.
Measurement BSC completes requesting for channel (due to handover and the
Point channel is used as signaling channel), or BSC receives the
internal message of waiting for resource successfully or waiting
for resource failed (C901260002 + C900060011). The
measurement point is C1 as shown in Figure 105 and Figure 106
and D1 as shown in Figure 107 and Figure 108.

FIGURE 105 – INTERNAL HANDOVER FLOW (INTRA-CELL HANDOVER, TC IS


INTERNAL)

MS BTS BSC MSC


MEAS_REP
MEAS_RES
C1
Abis,TCU connect
CHL_ACT C2

CHL_ACT_ACK

ASS_CMD C3
ASS_CMD
SABM

UA EST_IND
ASS_COM
ASS_COM

C4 HO_PREFORM

Confidential and Proprietary Information of ZTE CORPORATION 139


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 106 – INTERNAL HANDOVER FLOW (INTRA-CELL HANDOVER,


CHANNEL TYPE CHANGED, TC IS EXTERNAL)

MS BTS BSC iTC MSC


MEAS_REP
MEAS_RES
TCRescr Req

TCRescr Ack

C1
iTC Connect Req

iTC Connect Ack

C2
CHL_ACT
CHL_ACT_ACK

ASS_CMD C3
ASS_CMD
SABM
UA EST_IND
ASS_COM
ASS_COM

C4
HO_PREFORM

FIGURE 107 – EXTERNAL HANDOVER FLOW (TC IS INTERNAL)

140 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

FIGURE 108 – EXTERNAL HANDOVER FLOW (TC IS EXTERNAL )

Unit Times

C900060013
Definition Number of signaling TCH/F seizure failure for handover
Description This counter counts the number of TCH/F channel occupation
failures during signaling channel handover.
After BSC receives the channel request, it attempts to allocate
channel for the request.
„ If occupation fails, this counter accumulates.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource. If the waiting for resource fails, this counter
accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.
Measurement BSC requests for channel (due to handover and the channel is
Point used as signaling channel) but fails to occupy the channel, or
BSC fails to wait for internal resource. The measurement point is
C1 as shown in Figure 109 and D1 as shown in Figure 110.

FIGURE 109 – INTRA-BSC HANDOVER OCCUPATION FAILURE FLOW

Confidential and Proprietary Information of ZTE CORPORATION 141


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 110 – INTER-BSC HANDOVER OCCUPATION FAILURE FLOW

BSC MSC
HO_REQ
D
1 (TCH seizure fails, external
handover is not
implemented)

Unit Times

C900060014
Definition Number of signaling TCH/F allocation success for assignment
Description This counter counts the number TCH/F channel being allocated
successfully during signaling channel assignment.
After BSC responds the channel request message to allocate and
occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F channel. If the activation
succeeds (that is, when BSC receives the CHL_ACT_ACK
message from BTS), the counter accumulates.

Measurement The counter increments when BSC receives the CHL_ACT_ACK


Point message from BTS, the cause is due to assignment and the
channel is used as signaling channel. The measurement point is
A2, as shown in Figure 103.
Unit Times

C900060015
Definition Number of signaling TCH/F allocation failure for assignment
Description This counter counts the number of TCH/F channel allocation
failures during signaling channel assignment.
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F channel.
If the channel activation fails due to receiving channel activation
failure message, incorrect channel activation response message,
T9103 timeout, channel instance being released or channel
being released forcibly, this counter accumulates.
Measurement BSC activates TCH/F channel due to assignment and uses it as
Point signaling channel, but receives channel activation failure
message, incorrect channel activation response message, T9103
being timeout, channel instance being released, or channel being

142 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

forcibly released. The measurement point is A2, as shown in


Figure 111.

FIGURE 111 – IMMEDIATE ASSIGNMENT ALLOCATION F AILURE FLOW 2

MS BTS BSC
CHL_REQ
CHL_RQD
A1
CHL_ACT

CHL_ACT_NACK

A2

Unit Times

C900060016
Definition Number of signaling TCH/F allocation failure for handover
Description This counter counts the number of TCH/F channel allocation
failures during signaling channel handover.
After BSC responds the channel request message to allocate and
occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F channel.
If the channel activation fails due to receiving channel activation
failure message, incorrect channel activation response message,
T9103 timeout, channel instance being released or channel
being released forcibly, this counter will accumulate.
Measurement BSC activates TCH/F channel due to handover and uses it as
Point signaling channel, but receives channel activation failure
message, incorrect channel activation response message, T9103
being timeout, channel instance being released, or channel being
forcibly released.
The measurement point is C3 as shown in Figure 112 and D3 as
shown in Figure 113.

Confidential and Proprietary Information of ZTE CORPORATION 143


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 112 – INTERNAL HANDOVER FAILURE FLOW 1 (INTRA-CELL


HANDOVER, TC IS INTERNAL)

FIGURE 113 – EXTERNAL HANDOVER FAILURE FLOW 2 (TC IS INTERNAL)

MS BTS BSC MSC


HO_REQ
D1
Abis,TCU connect
CHL_ACT D2

CHL_ACT_NACK
... D3

Unit Times

C900060017
Definition Number of signaling TCH/F assignment success for assignment
Description This counter counts the number of successful assignments of
TCH/F as signaling channel.
After BSC responds the channel request message to allocate and
occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. For immediate
assignment, after the TCH/F activation succeeds, BTS finds the
MS accessed and sends the EST_IND message to BSC, this
counter accumulates when BSC receives the message correctly.
Measurement For immediate assignment, this counter counts when BSC
Point receives the EST_IND message correctly. The measurement
point is A3, as shown in Figure 103.
Unit Times

144 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

C900060018
Definition Number of signaling TCH/F assignment failure for assignment
Description This counter counts the number of failing to assign TCH/F
channel as signaling channel.
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. If BSC does not receive
the MS access notification within a certain time, this assignment
fails.
Measurement For immediate assignment, this counter counts when BSC
Point receives incorrect EST_IND message or T3101 is timeout. The
measurement point is A3, as shown in Figure 114

FIGURE 114 – IMMEDIATE ASSIGNMENT FAILURE FLOW 3

MS BTS BSC
CHL_REQ
CHL_RQD
A1
CHL_ACT

CHL_ACT_ACK
IMM_ASS_CM A2
IMM_ASS D

SABM Incorrect EST_IND


message, or T3101
timeout A3

Unit Times

C900060019
Definition Number of voice TCH/F seizure attempts
Description This counter counts the number of TCH/F channel being
attempted to be occupied during voice channel assignment,
including the number of occupation success (C901260021) and
the number of occupation failure (C900060020).
After BSC receives the channel request massage, it attempts to
allocate channel for the request.
„ If allocation and occupation succeed, C900060019 and
C901260021 accumulate simultaneously.
„ If occupation fails, C900060019 and C900060020
accumulate simultaneously.

Confidential and Proprietary Information of ZTE CORPORATION 145


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

„ If the request returns no channel available but queuing or


forced release is possible, enter the state of waiting for
resource.
f If the waiting for resource succeeds, C900060019 and
C901260021 accumulate simultaneously.
f If the waiting for resource fails, C900060019 and
C900060020 accumulate simultaneously.
„ If the request returns that the transceiver is faulty,
C900060019, C901260021, and C900060020 do not change.
„ For failures in other cases, C900060019 and C900060020
accumulate simultaneously.
Measurement BSC completes requesting for channel (due to assignment and
Point the channel is used as voice channel), or BSC receives the
internal message of waiting for resource successfully or waiting
for resource failed (C901260021 + C900060020). The
measurement point is B1, as shown in Figure 115 and Figure
116.

FIGURE 115 – COMMON ASSIGNMENT FLOW (TC IS INTERNAL)

MS BTS BSC MSC


ASS_REQ

B1
Abis,TCU connect
CHL_ACT B2

CHL_ACT_ACK

ASS_CMD B3
ASS_CMD
SABM

UA EST_IND
ASS_COM B4
ASS_COM

B5 ASS_COM

146 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

FIGURE 116 – COMMON ASSIGNMENT FLOW (TC IS EXTERNAL )

Unit Times

C900060020
Definition Number of voice TCH/F seizure failure
Description This counter counts the number of TCH/F channel occupation
failure during voice channel assignment.
After BSC receives the channel request message, it attempts to
allocate channel for the request.
„ If occupation fails, this counter accumulates.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource. If the waiting for resource fails, this counter
accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.
Measurement BSC requests for channel (due to assignment and the channel is
Point used as voice channel) but fails to occupy the channel, or BSC
fails to wait for internal resource. The measurement point is B1,
as shown in Figure 117.

Confidential and Proprietary Information of ZTE CORPORATION 147


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 117 – COMMON ASSIGNMENT FAILURE FLOW 1 (TC IS INTERNAL)

BSC MSC
ASS_REQ
Channel
seizure B1
ASS_FAIL
fails

Unit Times

C900060021
Definition Number of voice TCH/F seizure attempts for handover
Description This counter counts the number of TCH/F channel being
attempted to be occupied during voice channel handover,
including the number of occupation success (C901260024) and
the number of occupation failure (C900060022).
After BSC receives the channel request massage, it attempts to
allocate channel for the request.
„ If allocation and occupation succeed, C900060021 and
C901260024 accumulate simultaneously.
„ If occupation fails, C900060021 and C900060022
accumulate simultaneously.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource.
f If the waiting for resource succeeds, C900060021 and
C901260024 accumulate simultaneously.
f If the waiting for resource fails, C900060021 and
C900060022 accumulate simultaneously.
„ If the request returns that the transceiver is faulty,
C900060021, C901260024, and C900060022 do not change.
„ For failures in other cases, C900060021 and C900060022
accumulate simultaneously.
Measurement BSC completes requesting for channel (due to handover and the
Point channel is used as voice channel), or BSC receives the internal
message of waiting for resource successfully or waiting for
resource failed (C901260024 + C900060022). The measurement
point is C1 as shown in Figure 105 and Figure 106 and D1 as
shown in Figure 107 and Figure 108.
Unit Times

148 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

C900060022
Definition Number of voice TCH/F seizure failure for handover
Description This counter counts the number of TCH/F channel occupation
failure during voice channel handover.
After BSC receives the channel request message, it attempts to
allocate channel for the request.
„ If allocation or occupation fails, this counter accumulates.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource. If the waiting for resource fails, this counter
accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.
Measurement BSC requests for channel (due to handover and the channel is
Point used as voice channel) but fails to occupy the channel, or BSC
fails to wait for internal resource. The measurement point is C1
as shown in Figure 109 and D1 as shown in Figure 110.
Unit Times

C900060023
Definition Number of TCH/F allocation success for assignment (speech
version1)
Description This counter counts the number of TCH/F channel being
allocated successfully during voice channel assignment (speech
version 1).
After BSC responds the channel request message to allocate and
occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. If the TCH/F is activated
successfully (that is, when BSC receives the CHL_ACT_ACK
message from BTS), this counter accumulates.
Measurement This counter counts when BSC receives the CHL_ACT_ACK
Point message from BTS, the cause is assignment and the channel is
used as voice channel (speech version 1). The measurement
point is B3, as shown in Figure 115 and Figure 116.
Unit Times

C900060024
Definition

Confidential and Proprietary Information of ZTE CORPORATION 149


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Number of TCH/F allocation failure for assignment (speech


version1)
Description This counter counts the number of TCH/F channel allocation
failure due to channel activation failure during voice channel
assignment (speech version 1).
After BSC responds the channel request message to allocate and
occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. If channel activation fails
due to receiving channel activation failure message, incorrect
channel activation response message, T9103 being timeout,
channel instance being released or channel being forcibly
released, this counter accumulates.
Measurement BSC activates TCH/F channel due to assignment and uses the
Point channel as voice channel (speech version 1), but receives
channel activation failure message, incorrect channel activation
response message, T9103 being timeout, channel instance being
released, or channel being forcibly released. The measurement
point is B3, as shown in Figure 118.

FIGURE 118 – COMMON ASSIGNMENT FAILURE FLOW 1 (TC IS INTERNAL)

Unit Times

C900060025
Definition Number of TCH/F allocation success for assignment (speech
version2)
Description This counter counts the number of TCH/F channel being
allocated successfully during voice channel assignment (speech
version 2).
After BSC responds the channel request message to allocate and
occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. If the TCH/F is activated
successfully (that is, when BSC receives the CHL_ACT_ACK
message from BTS), this counter accumulates.
Measurement This counter counts when BSC receives the CHL_ACT_ACK
Point message from BTS, the cause is assignment and the channel is

150 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

used as voice channel (speech version 2). The measurement


point is B3, as shown in Figure 115 and Figure 116.
Unit Times

C900060026
Definition Number of TCH/F allocation success for assignment (speech
version3)
Description This counter counts the number of TCH/F channel being
allocated successfully during voice channel assignment (speech
version 3).
After BSC responds the channel request message to allocate and
occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. If the TCH/F is activated
successfully (that is, when BSC receives the CHL_ACT_ACK
message from BTS), this counter accumulates.
Measurement This counter counts when BSC receives the CHL_ACT_ACK
Point message from BTS, the cause is assignment and the channel is
used as voice channel (speech version 3). The measurement
point is B3, as shown in Figure 115 and Figure 116.
Unit Times

C900060027
Definition Number of TCH/F allocation failure for assignment (speech
version3)
Description This counter counts the number of TCH/F channel allocation
failure due to channel activation failure during voice channel
assignment (speech version 3).
After BSC responds the channel request message to allocate and
occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. If channel activation fails
due to receiving channel activation failure message, incorrect
channel activation response message, T9103 being timeout,
channel instance being released or channel being forcibly
released, this counter accumulates.
Measurement BSC activates TCH/F channel due to assignment and uses the
Point channel as voice channel (speech version 3), but receives
channel activation failure message, incorrect channel activation
response message, T9103 being timeout, channel instance being
released, or channel being forcibly released. The measurement
point is B3, as shown in Figure 118.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 151


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060028
Definition Number of voice TCH/F assignment success
Description This counter counts the number of successful assignments of
TCH/F as voice channel.
After BSC responds the channel request message to allocate and
occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. For assignment from A-
interface, after BSC receives the assignment success message,
the counter accumulates.
Measurement For assignment from A-interface, the counter accumulates when
Point BSC receives the assignment success message. The
measurement point is B5, as shown in Figure 115 and Figure
116.
Unit Times

C900060029
Definition Number of voice TCH/F assignment failure for assignment
Description This counter counts the number of failing to assign TCH/F
channel as voice channel.
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. If BSC does not receive
the MS access notification within a certain time, this assignment
fails.
Measurement This counter counts when BSC receives assignment failure
Point message, abnormal message, channel instance being released,
channel instance being released forcibly, or timer timeout
message. The measurement point is B5, as shown in Figure 119.

152 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

FIGURE 119 – COMMON ASSIGNMENT FAILURE FLOW 4 (TC IS INTERNAL)

MS BTS BSC MSC


ASS_REQ

B1
Abis,TCU connect
CHL_ACT B2

CHL_ACT_ACK

ASS_CMD B3
ASS_CMD
SABM

UA EST_IND
ASS_FAIL B4
ASS_FAIL

B5 ASS_FAIL

Unit Times

C900060030
Definition Number of data TCH/F seizure attempts for assignment
Description This counter counts the number of TCH/F channel being
attempted to be occupied during data channel assignment,
including the number of occupation success (C901260070) and
the number of occupation failure (C900060031).
After BSC receives the channel request massage, it attempts to
allocate channel for the request.
„ If allocation and occupation succeed, C900060030 and
C901260070 accumulate simultaneously.
„ If occupation fails, C900060030 and C900060031
accumulate simultaneously.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource.
f If the waiting for resource succeeds, C900060030 and
C901260070 accumulate simultaneously.
f If the waiting for resource fails, C900060030 and
C900060031 accumulate simultaneously.
„ If the request returns that the transceiver is faulty,
C900060030, C901260070, and C900060031 do not change.
„ For failures in other cases, C900060030 and C900060031
accumulate simultaneously.
Measurement BSC completes requesting for channel (due to assignment and
Point the channel is used as data channel), or BSC receives the

Confidential and Proprietary Information of ZTE CORPORATION 153


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

internal message of waiting for resource successfully or waiting


for resource failed (C901260070 + C900060031). The
measurement point is B1, as shown in Figure 115 and Figure
116.
Unit Times

C900060031
Definition Number of data TCH/F seizure failure for assignment
Description This counter counts the number of TCH/F channel occupation
failure during data channel assignment.
After BSC receives the channel request message, it attempts to
allocate channel for the request.
„ If occupation fails, this counter accumulates.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource. If the waiting for resource fails, this counter
accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.
Measurement BSC requests for channel (due to assignment and the channel is
Point used as data channel) but fails to occupy the channel, or BSC
fails to wait for internal resource. The measurement point is B1,
as shown in Figure 117.
Unit Times

C900060032
Definition Number of data TCH/F seizure attempts for handover
Description This counter counts the number of TCH/F channel being
attempted to be occupied during data channel handover,
including the number of occupation success (C901260073) and
the number of occupation failure (C900060033).
After BSC receives the channel request massage, it attempts to
allocate channel for the request.
„ If allocation and occupation succeed, C900060032 and
C901260073 accumulate simultaneously.
„ If occupation fails, C900060032 and C900060033
accumulate simultaneously.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource.

154 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

f If the waiting for resource succeeds, C900060032 and


C901260073 accumulate simultaneously.
f If the waiting for resource fails, C900060032 and
C900060033 accumulate simultaneously.
„ If the request returns that the transceiver is faulty,
C900060032, C901260073, and C900060033 do not change.
„ For failures in other cases, C900060032 and C900060033
accumulate simultaneously.
Measurement BSC completes requesting for channel (due to handover and the
Point channel is used as data channel), or BSC receives the internal
message of waiting for resource successfully or waiting for
resource failed (C901260073 + C900060033). The measurement
point is C1 as shown in Figure 105 and Figure 106 and D1 as
shown in Figure 107 and Figure 108.
Unit Times

C900060033
Definition Number of data TCH/F seizure failure for handover
Description This counter counts the number of TCH/F channel occupation
failure during data channel handover.
After BSC receives the channel request message, it attempts to
allocate channel for the request.
„ If occupation fails, this counter accumulates.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource. If the waiting for resource fails, this counter
accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.
Measurement BSC requests for channel (due to handover and the channel is
Point used as data channel) but fails to occupy the channel, or BSC
fails to wait for internal resource. The measurement point is C1
as shown in Figure 109 and D1 as shown in Figure 110.
Unit Times

C900060034
Definition Number of data TCH/F allocation success for assignment
Description This counter counts the number of TCH/F channel being
allocated successfully during data channel assignment.

Confidential and Proprietary Information of ZTE CORPORATION 155


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

After BSC responds the channel request message to allocate and


occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. If the TCH/F is activated
successfully (that is, when BSC receives the CHL_ACT_ACK
message from BTS), this counter accumulates.
Measurement This counter counts when BSC receives the CHL_ACT_ACK
Point message from BTS, the cause is assignment and the channel is
used as data channel. The measurement point is B3, as shown in
Figure 115 and Figure 116.
Unit Times

C900060035
Definition Number of data TCH/F allocation failure for assignment
Description This counter counts the number of TCH/F channel allocation
failure due to channel activation failure during data channel
assignment.
After BSC responds the channel request message to allocate and
occupy TCH/F channel successfully, if connection succeeds, BSC
sends the CHL_ACT message to BTS to activate this TCH/F. If
channel activation fails due to receiving channel activation
failure message, incorrect channel activation response message,
T9103 being timeout, channel instance being released or
channel being forcibly released, this counter accumulates.
Measurement BSC activates TCH/F channel due to assignment and uses the
Point channel as data channel, but receives channel activation failure
message, incorrect channel activation response message, T9103
being timeout, channel instance being released, or channel being
forcibly released. The measurement point is B3, as shown in
Figure 118.
Unit Times

C900060036
Definition Number of data TCH/F assignment success
Description This counter counts the number of successful assignments of
TCH/F as data channel.
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. For assignment from A-
interface, after BSC receives the assignment success message,
the counter accumulates.
Measurement For assignment from A-interface, the counter accumulates when
Point BSC receives the assignment success message. The

156 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

measurement point is B5, as shown in Figure 115 and Figure


116.
Unit Times

C900060037
Definition Number of data TCH/F assignment failure
Description This counter counts the number of failing to assign TCH/F
channel as data channel.
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. If BSC does not receive
the MS access notification within a certain time, this assignment
fails.
Measurement This counter counts when BSC receives assignment failure
Point message, abnormal message, channel instance being released,
channel instance being released forcibly, or timer timeout
message. The measurement point is B5, as shown in Figure 119.
Unit Times

C900060038
Definition Number of signaling TCH/H seizure attempts for assignment
Description This counter counts the number of TCH/H channel being
attempted to be occupied during signaling channel assignment,
including the number of occupation success (C901270002) and
the number of occupation failure (C900060039).
After BSC receives the channel request massage, it attempts to
allocate channel for the request.
„ If allocation and occupation succeed, C900060038 and
C901270002 accumulate simultaneously.
„ If the request returns that the transceiver is faulty,
C900060038, C901270002, and C900060039 do not change.
„ For other cases, C900060038 and C900060039 accumulate
simultaneously.
Measurement This counter counts when BSC completes requesting for channel
Point (due to assignment and the channel is used as signaling channel)
(C901270002 + C900060039). The measurement point is A1, as
shown in Figure 103.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 157


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060039
Definition Number of signaling TCH/H seizure failure for assignment
Description This counter counts the number of TCH/H channel occupation
failure during signaling channel assignment.
After BSC receives the channel request message, it attempts to
allocate channel for the request.
„ If occupation fails, this counter accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.
Measurement BSC requests for channel (due to assignment and the channel is
Point used as signaling channel) but fails to occupy the channel, or
BSC fails to wait for internal resource. The measurement point is
A1, as shown in Figure 104.
Unit Times

C900060040
Definition Number of signaling TCH/H seizure attempts for handover
Description This counter counts the number of TCH/H channel being
attempted to be occupied during signaling channel handover,
including the number of occupation success (C901270005) and
the number of occupation failure (C900060041).
After BSC receives the channel request, it attempts to allocate
channel for the request.
„ If allocation and occupation succeed, C900060040 and
C901270005 accumulate simultaneously.
„ If occupation fails, C900060040 and C900060041
accumulate simultaneously.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource.
f If the waiting for resource succeeds, C900060040 and
C901270005 accumulate simultaneously.
f If the waiting for resource fails, C900060040 and
C900060041 accumulate simultaneously.
„ If the request returns that the transceiver is faulty,
C900060040, C901270005, and C900060041 do not change.
„ For failures in other cases, C900060040 and C900060041
accumulate simultaneously.

158 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Measurement BSC completes requesting for channel (due to handover and the
Point channel is used as signaling channel), or BSC receives the
internal message of waiting for resource successfully or waiting
for resource failed (C901270005 + C900060041). The
measurement point is C1 as shown in Figure 105 and Figure 106
and D1 as shown in Figure 107 and Figure 108.
Unit Times

C900060041
Definition Number of signaling TCH/H seizure failure for handover
Description This counter counts the number of TCH/H channel occupation
failures during signaling channel handover.
After BSC receives the channel request, it attempts to allocate
channel for the request.
„ If occupation fails, this counter accumulates.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource. If the waiting for resource fails, this counter
accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.
Measurement BSC requests for channel (due to handover and the channel is
Point used as signaling channel) but fails to occupy the channel, or
BSC fails to wait for internal resource. The measurement point is
C1 as shown in Figure 109 and D1 as shown in Figure 110.
Unit Times

C900060042
Definition Number of voice TCH/H seizure attempts for assignment
Description This counter counts the number of TCH/H channel being
attempted to be occupied during voice channel assignment,
including the number of occupation success (C901270021) and
the number of occupation failure (C900060043).
After BSC receives the channel request massage, it attempts to
allocate channel for the request.
„ If allocation and occupation succeed, C900060042 and
C901270021 accumulate simultaneously.
„ If occupation fails, C900060042 and C900060043
accumulate simultaneously.

Confidential and Proprietary Information of ZTE CORPORATION 159


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

„ If the request returns no channel available but queuing or


forced release is possible, enter the state of waiting for
resource.
f If the waiting for resource succeeds, C900060042 and
C901270021 accumulate simultaneously.
f If the waiting for resource fails, C900060042 and
C900060043 accumulate simultaneously.
„ If the request returns that the transceiver is faulty,
C900060042, C901270021, and C900060043 do not change.
„ For failures in other cases, C900060042 and C900060043
accumulate simultaneously.
Measurement BSC completes requesting for channel (due to assignment and
Point the channel is used as voice channel), or BSC receives the
internal message of waiting for resource successfully or waiting
for resource failed (C901270021 + C900060043). The
measurement point is B1, as shown in Figure 115 and Figure
116.
Unit Times

C900060043
Definition Number of voice TCH/H seizure failure for assignment
Description This counter counts the number of TCH/H channel occupation
failure during voice channel assignment.
After BSC receives the channel request message, it attempts to
allocate channel for the request.
„ If occupation fails, this counter accumulates.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource. If the waiting for resource fails, this counter
accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.
Measurement BSC requests for channel (due to assignment and the channel is
Point used as voice channel) but fails to occupy the channel, or BSC
fails to wait for internal resource. The measurement point is B1,
as shown in Figure 117.
Unit Times

C900060044
Definition Number of voice TCH/H seizure attempts for handover

160 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Description This counter counts the number of TCH/H channel being


attempted to be occupied during voice channel handover,
including the number of occupation success (C901270024) and
the number of occupation failure (C900060045).
After BSC receives the channel request massage, it attempts to
allocate channel for the request.
„ If allocation and occupation succeed, C900060044 and
C901270024 accumulate simultaneously.
„ If occupation fails, C900060044 and C900060045
accumulate simultaneously.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource.
f If the waiting for resource succeeds, C900060044 and
C901270024 accumulate simultaneously.
f If the waiting for resource fails, C900060044 and
C900060045 accumulate simultaneously.
„ If the request returns that the transceiver is faulty,
C900060044, C901270024, and C900060045 do not change.
„ For failures in other cases, C900060044 and C900060045
accumulate simultaneously.
Measurement BSC completes requesting for channel (due to handover and the
Point channel is used as voice channel), or BSC receives the internal
message of waiting for resource successfully or waiting for
resource failed (C901270024 + C900060045). The measurement
point is C1 as shown in Figure 105 and Figure 106 and D1 as
shown in Figure 107 and Figure 108.
Unit Times

C900060045
Definition Number of voice TCH/H seizure failure for handover
Description This counter counts the number of TCH/H channel occupation
failure during voice channel handover.
After BSC receives the channel request message, it attempts to
allocate channel for the request.
„ If allocation or occupation fails, this counter accumulates.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource. If the waiting for resource fails, this counter
accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.

Confidential and Proprietary Information of ZTE CORPORATION 161


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Measurement BSC requests for channel (due to handover and the channel is
Point used as voice channel) but fails to occupy the channel, or BSC
fails to wait for internal resource. The measurement point is C1
as shown in Figure 109 and D1 as shown in Figure 110.
Unit Times

C900060046
Definition Number of data TCH/H seizure attempts for assignment
Description This counter counts the number of TCH/H channel being
attempted to be occupied during data channel assignment,
including the number of occupation success (C901270070) and
the number of occupation failure (C900060047).
After BSC receives the channel request massage, it attempts to
allocate channel for the request.
„ If allocation and occupation succeed, C900060046 and
C901270070 accumulate simultaneously.
„ If occupation fails, C900060046 and C900060047
accumulate simultaneously.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource.
f If the waiting for resource succeeds, C900060046 and
C901270070 accumulate simultaneously.
f If the waiting for resource fails, C900060046 and
C900060047 accumulate simultaneously.
„ If the request returns that the transceiver is faulty,
C900060046, C901270070, and C900060047 do not change.
„ For failures in other cases, C900060046 and C900060047
accumulate simultaneously.
Measurement BSC completes requesting for channel (due to assignment and
Point the channel is used as data channel), or BSC receives the
internal message of waiting for resource successfully or waiting
for resource failed (C901270070 + C900060047). The
measurement point is B1, as shown in Figure 115 and Figure
116.
Unit Times

C900060047
Definition Number of data TCH/H seizure failure for assignment
Description This counter counts the number of TCH/H channel occupation
failure during data channel assignment.

162 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

After BSC receives the channel request message, it attempts to


allocate channel for the request.
„ If occupation fails, this counter accumulates.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource. If the waiting for resource fails, this counter
accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.
Measurement BSC requests for channel (due to assignment and the channel is
Point used as data channel) but fails to occupy the channel, or BSC
fails to wait for internal resource. The measurement point is B1,
as shown in Figure 117.
Unit Times

C900060048
Definition Number of data TCH/H seizure attempts for handover
Description This counter counts the number of TCH/H channel being
attempted to be occupied during data channel handover,
including the number of occupation success (C901270073) and
the number of occupation failure (C900060049).
After BSC receives the channel request massage, it attempts to
allocate channel for the request.
„ If allocation and occupation succeed, C900060048 and
C901270073 accumulate simultaneously.
„ If occupation fails, C900060048 and C900060049
accumulate simultaneously.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource.
f If the waiting for resource succeeds, C900060048 and
C901270073 accumulate simultaneously.
f If the waiting for resource fails, C900060048 and
C900060049 accumulate simultaneously.
„ If the request returns that the transceiver is faulty,
C900060048, C901270073, and C900060049 do not change.
„ For failures in other cases, C900060048 and C900060049
accumulate simultaneously.
Measurement BSC completes requesting for channel (due to handover and the
Point channel is used as data channel), or BSC receives the internal
message of waiting for resource successfully or waiting for
resource failed (C901270073 + C900060049). The measurement

Confidential and Proprietary Information of ZTE CORPORATION 163


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

point is C1 as shown in Figure 105 and Figure 106 and D1 as


shown in Figure 107 and Figure 108.
Unit Times

C900060049
Definition Number of data TCH/H seizure failure for handover
Description This counter counts the number of TCH/H channel occupation
failure during data channel handover.
After BSC receives the channel request message, it attempts to
allocate channel for the request.
„ If occupation fails, this counter accumulates.
„ If the request returns no channel available but queuing or
forced release is possible, enter the state of waiting for
resource. If the waiting for resource fails, this counter
accumulates.
„ If the request returns that the transceiver is faulty, this
counter does not change.
„ For failures in other cases, this counter accumulates.
Measurement BSC requests for channel (due to handover and the channel is
Point used as data channel) but fails to occupy the channel, or BSC
fails to wait for internal resource. The measurement point is C1
as shown in Figure 109 and D1 as shown in Figure 110.
Unit Times

C900060050
Definition Number of SAPI3 link establishment requests on SDCCH (MO-SM)
Description This counter counts the number of short message link
establishments of mobile originating call on SDCCH. On SDCCH,
BSC receives the EST_IND message sent by BTS. If the layer-3
information in this message is SAPI = 3, this counter increments.
Usage This counter is used to find out the frequency of SAPI 3 link
establishment on SDCCH.
Measurement This counter counts when BSC receives the EST_IND message
Point (SAPI = 3) from BTS. The measurement point is B1, as shown in
Figure 120.

164 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

FIGURE 120 – IDLE-STATE MO SHORT MESSAGE FLOW

SDCCH

Unit Times

C900060051
Definition Number of SAPI3 link establishment requests on SDCCH (MT-SM)
Description This counter counts the number of short message link
establishments of mobile terminating call on SDCCH. On SDCCH,
if BSC receives the DTAP_IND message (SAPI = 3) sent by MSC
and the short message link between BSC and MS is not
established, BSC initiates the link establishment flow, this
counter increments.
Usage This counter is used to find out the frequency of SAPI 3 link
establishment request on SDCCH.
Measurement This counter counts when BSC sends the EST_REQ message
Point (SAPI = 3) to BTS and the short message link is not established
between BSC and MS. The measurement point is D1, as shown
in Figure 121.

Confidential and Proprietary Information of ZTE CORPORATION 165


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 121 – IDLE-STATE MT SHORT MESSAGE FLOW

MS BTS BSC MSC

Paging
Paging Cmd
Paging Request
Chan Request
Chan Required
Chan Activation
Chan Act ACK
Imm Ass Cmd(Imm Ass)
Imm Ass
SABM(Paging Resp)
Est Ind ( Paging Resp)
CR (Paging Resp )
UA
CC (Authentication Req)

Authentication And Encryption

From SC
CP_ DATA(RP_ DATA)
Est Req (SAPI=3)
SABM(SAPI=3)
SDCCH

UA D1
Est Conf ( SAPI=3)
D2
CP_DATA(RP_ DATA)
D3
CP_ ACK
D4
CP_ DATA(RP_ ACK) To SC

D5
CP_ ACK
D6
Clear Cmd
Data Req (Chan Release)
Chan Release Clear Cmp
Deact SACCH
DISC
Release Ind
RF Chan Release
RF Chan Release ACK

Unit Times

C900060052
Definition Number of SDCCH drops due to handover failure
Description This counter counts the number of call drops due to handover
failure on SDCCH. Call drop occurs after MS requests for SDCCH
successfully. If the problem is due to handover failure, this
counter increments.
Presently, reasons for handover failure include T3107 timeout,
T3103 timeout and external handover timer timeout under the
status of ASSIGNING.
T3107 indicates the duration from sending the intra-cell
handover command ASSIGN_CMD to receiving the assignment
completion message ASSIGN_COM. T3103 indicates the duration
from sending the inter-cell handover command HOINTER_CMD

166 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

to receiving the assignment completion message HOINTER_COM.


The external handover timer indicates the duration from sending
the inter-cell external handover command to receiving the
handover completion message.
Usage This counter is used to find out the frequency of call drop due to
handover failure on SDCCH.
Measurement SDCCH is activated after BSC initiates the handover flow. After
Point that:
„ If RANCS is in the status of RADIO_APPLY and sends the
intra-cell handover command, then T3107 is started. If
RANCS is in the status of ASSIGN and T3107 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 122.

FIGURE 122 – CALL DROP DUE TO T3107 TIMEOUT DURING INTRA-CELL


HANDOVER

„ If RANCS is in the status of RADIO_APPLY and sends the


inter-cell handover command, then T3103 is started. If
RANCS is in the status of ASSIGN and T3103 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 123.

Confidential and Proprietary Information of ZTE CORPORATION 167


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 123 – CALL DROP DUE TO T3103 TIMEOUT DURING INTER-CELL


HANDOVER

„ If RANCS is in the status of RADIO_APPLY and sends the


external handover command, then the external handover
timer is started. If RANCS is in the status of ASSIGN and the
external handover timer is timeout, then the counter
increments.
Unit Times

C900060053
Definition Number of SDCCH drops
Description This counter counts the number of call drops on SDCCH channel
due to radio link failure, LAPD link break, or handover failure.
Call drop occurs after MS requests for TCH/H channel
successfully. The counter increments if call drop is due to the
above causes.
Usage This counter is used to find out the frequency of call drop on
SDCCH channel due to radio link failure, LAPD link break, or
handover failure.
Measurement This counter increments when call drop occurs on SDCCH
Point channel due to radio link failure, LAPD link failure, or handover
failure.
Unit Times

C900060054
Definition Number of TCH/F drops
Description This counter counts the number of call drops on TCH/F channel
due to radio link failure, LAPD link break, or handover failure.
Call drop occurs after MS requests for TCH/H channel

168 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

successfully. The counter increments if call drop is due to the


above causes.

Usage This counter is used to find out the frequency of call drop on
TCH/F channel due to radio link failure, LAPD link break, or
handover failure.
Measurement The counter increments when call drop occurs on TCH/F channel
Point due to radio link failure, LAPD link failure, or handover failure.
Unit Times

C900060055
Definition Number of TCH/H drops
Description This counter counts the number of call drops on TCH/H channel
due to radio link failure, LAPD link break, or handover failure.
Call drop occurs after MS requests for TCH/H channel
successfully. The counter increments if call drop is due to the
above causes.
Usage This counter is used to find out the frequency of call drop on
TCH/H channel due to radio link failure, LAPD link break, or
handover failure.
Measurement The counter increments when call drop occurs on TCH/H channel
Point due to radio link failure, LAPD link failure, or handover failure.
Unit Times

C900060056
Definition Average number of idle TCH/F with interference band 1
Description This counter counts the number of idle TCH/Fs with interference
band 1 in the carrier.
Usage This counter is used to find out the number of idle TCH/Fs with
interference band 1.
Measurement This counter counts when querying the database periodically.
Point

Unit Times

C900060057
Definition Average number of idle TCH/F with interference band 2
Description This counter counts the number of idle TCH/Fs with interference
band 2 in the carrier.

Confidential and Proprietary Information of ZTE CORPORATION 169


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Usage This counter is used to find out the number of idle TCH/Fs with
interference band 2.
Measurement This counter counts when querying the database periodically.
Point

Unit Times

C900060058
Definition Average number of idle TCH/F with interference band 3
Description This counter counts the number of idle TCH/Fs with interference
band 3 in the carrier.
Usage This counter is used to find out the number of idle TCH/Fs with
interference band 3.
Measurement This counter counts when querying the database periodically.
Point

Unit Times

C900060059
Definition Average number of idle TCH/F with interference band 4
Description This counter counts the number of idle TCH/Fs with interference
band 4 in the carrier.
Usage This counter is used to find out the number of idle TCH/Fs with
interference band 4.
Measurement This counter counts when querying the database periodically.
Point

Unit Times

C900060060
Definition Average number of idle TCH/F with interference band 5
Description This counter counts the number of idle TCH/Fs with interference
band 5 in the carrier.
Usage This counter is used to find out the number of idle TCH/Fs with
interference band 5.
Measurement This counter counts when querying the database periodically.
Point

Unit Times

170 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

C900060061
Definition Average number of idle TCH/H with interference band 1
Description This counter counts the number of idle TCH/Hs with interference
band 1 in the carrier.
Usage This counter is used to find out the number of idle TCH/Hs with
interference band 1.

Measurement This counter counts when querying the database periodically.


Point

Unit Times

C900060062
Definition Average number of idle TCH/H with interference band 2
Description This counter counts the number of idle TCH/Hs with interference
band 2 in the carrier.
Usage This counter is used to find out the number of idle TCH/Hs with
interference band 2.
Measurement This counter counts when querying the database periodically.
Point

Unit Times

C900060063
Definition Average number of idle TCH/H with interference band 3
Description This counter counts the number of idle TCH/Hs with interference
band 3 in the carrier.
Usage This counter is used to find out the number of idle TCH/Hs with
interference band 3.
Measurement This counter counts when querying the database periodically.
Point

Unit Times

C900060064
Definition Average number of idle TCH/H with interference band 4
Description

Confidential and Proprietary Information of ZTE CORPORATION 171


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

This counter counts the number of idle TCH/Hs with interference


band 4 in the carrier.
Usage This counter is used to find out the number of idle TCH/Hs with
interference band 4.
Measurement This counter counts when querying the database periodically.
Point

Unit Times

C900060065
Definition Average number of idle TCH/H with interference band 5
Description This counter counts the number of idle TCH/Hs with interference
band 5 in the carrier.
Usage This counter is used to find out the number of idle TCH/Hs with
interference band 5.
Measurement This counter counts when querying the database periodically.
Point

Unit Times

C900060066
Definition Number of samples with UL RQ = 0
Description This counter counts the number of samples with Uplink (UL)
Receiving Quality (RQ) = 0. After BSC receives the
measurement report or preprocessing measurement report, if
the UL RQ = 0, the counter increments.
Usage This counter is used to count the number of samples with UL RQ
= 0.
Measurement The counter increments if UL RQ = 0 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060067
Definition Number of samples with UL RQ = 1
Description This counter counts the number of samples with UL RQ = 1.
After BSC receives the measurement report or preprocessing
measurement report, if the UL RQ = 1, the counter increments.
Usage This counter is used to count the number of samples with UL RQ
= 1.

172 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Measurement The counter increments if UL RQ = 1 in the measurement report


Point or preprocessing measurement report that BSC receives.
Unit Times

C900060068
Definition Number of samples with UL RQ = 2
Description This counter counts the number of samples with UL RQ = 2.
After BSC receives the measurement report or preprocessing
measurement report, if the UL RQ = 2, the counter increments.
Usage This counter is used to count the number of samples with UL RQ
= 2.
Measurement The counter increments if UL RQ = 2 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060069
Definition Number of samples with UL RQ = 3
Description This counter counts the number of samples with UL RQ = 3.
After BSC receives the measurement report or preprocessing
measurement report, if the UL RQ = 3, the counter increments.
Usage This counter is used to count the number of samples with UL RQ
= 3.
Measurement The counter increments if UL RQ = 3 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060070
Definition Number of samples with UL RQ = 4
Description This counter counts the number of samples with UL RQ = 4.
After BSC receives the measurement report or preprocessing
measurement report, if the UL RQ = 4, the counter increments.
Usage This counter is used to count the number of samples with UL RQ
= 4.
Measurement The counter increments if UL RQ = 4 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 173


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060071
Definition Number of samples with UL RQ = 5
Description This counter counts the number of samples with UL RQ = 5.
After BSC receives the measurement report or preprocessing
measurement report, if the UL RQ = 5, the counter increments.
Usage This counter is used to count the number of samples with UL RQ
= 5.
Measurement The counter increments if UL RQ = 5 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060072
Definition Number of samples with UL RQ = 6
Description This counter counts the number of samples with UL RQ = 6.
After BSC receives the measurement report or preprocessing
measurement report, if the UL RQ = 6, the counter increments.

Usage This counter is used to count the number of samples with UL RQ


= 6.
Measurement The counter increments if UL RQ = 6 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060073
Definition Number of samples with UL RQ = 7
Description This counter counts the number of samples with UL RQ = 7.
After BSC receives the measurement report or preprocessing
measurement report, if the UL RQ = 7, the counter increments.
Usage This counter is used to count the number of samples with UL RQ
= 7.
Measurement The counter increments if UL RQ = 7 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060074
Definition Number of samples with DL RQ = 0

174 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Description This counter counts the number of samples with Downlink (DL)
RQ = 0. After BSC receives the measurement report or
preprocessing measurement report, if the DL RQ = 0, the
counter increments.
Usage This counter is used to count the number of samples with DL RQ
= 0.
Measurement The counter increments if DL RQ = 0 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060075
Definition Number of samples with DL RQ = 1
Description This counter counts the number of samples with DL RQ = 1.
After BSC receives the measurement report or preprocessing
measurement report, if the DL RQ = 1, the counter increments.
Usage This counter is used to count the number of samples with DL RQ
= 1.
Measurement The counter increments if DL RQ = 1 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060076
Definition Number of samples with DL RQ = 2
Description This counter counts the number of samples with DL RQ = 2.
After BSC receives the measurement report or preprocessing
measurement report, if the DL RQ = 2, the counter increments.
Usage This counter is used to count the number of samples with DL RQ
= 2.
Measurement The counter increments if DL RQ = 2 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060077
Definition Number of samples with DL RQ = 3
Description This counter counts the number of samples with DL RQ = 3.
After BSC receives the measurement report or preprocessing
measurement report, if the DL RQ = 3, the counter increments.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 175


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

This counter is used to count the number of samples with DL RQ


= 3.
Measurement The counter increments if DL RQ = 3 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060078
Definition Number of samples with DL RQ = 4
Description This counter counts the number of samples with DL RQ = 4.
After BSC receives the measurement report or preprocessing
measurement report, if the DL RQ = 4, the counter increments.
Usage This counter is used to count the number of samples with DL RQ
= 4.
Measurement The counter increments if DL RQ = 4 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060079
Definition Number of samples with DL RQ = 5
Description This counter counts the number of samples with DL RQ = 5.
After BSC receives the measurement report or preprocessing
measurement report, if the DL RQ = 5, the counter increments.
Usage This counter is used to count the number of samples with DL RQ
= 5.
Measurement The counter increments if DL RQ = 5 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060080
Definition Number of samples with DL RQ = 6
Description This counter counts the number of samples with DL RQ = 6.
After BSC receives the measurement report or preprocessing
measurement report, if the DL RQ = 6, the counter increments.
Usage This counter is used to count the number of samples with DL RQ
= 6.
Measurement The counter increments if DL RQ = 6 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

176 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

C900060081
Definition Number of samples with DL RQ = 7
Description This counter counts the number of samples with DL RQ = 7.
After BSC receives the measurement report or preprocessing
measurement report, if the DL RQ = 7, the counter increments.
Usage This counter is used to count the number of samples with DL RQ
= 7.
Measurement The counter increments if DL RQ = 7 in the measurement report
Point or preprocessing measurement report that BSC receives.
Unit Times

C900060082
Definition Number of TCH/F handover attempts due to UL strength
Description This counter counts the number of handover attempts due to UL
receiving strength too low on TCH/F channel.
Usage This counter is used to find out the frequency of handover due to
UL receiving strength on TCH/F channel. If the counter’s value is
too large, it indicates poor UL level on TCH/F channel.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/F channel. If handover decision succeeds and the
handover is due to UL strength, this counter increments. The
measurement point is A, as shown in Figure 124.

FIGURE 124 – HANDOVER DECISION

Unit Times

C900060083
Definition Number of TCH/F handover attempts due to DL strength
Description This counter counts the number of times of handover attempts
due to DL receiving strength too low on TCH/F channel.
Usage This counter is used to find out the frequency of handover due to
DL receiving strength on TCH/F channel. If the counter’s value is
too large, it indicates poor DL level on TCH/F channel.

Confidential and Proprietary Information of ZTE CORPORATION 177


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Measurement BSC performs handover decision after receiving measurement


Point report on TCH/F channel. If handover decision succeeds and the
handover is due to DL strength, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060084
Definition Number of TCH/F handover attempts due to UL quality
Description This counter counts the number of handover attempts due to UL
quality too poor on TCH/F channel.
Usage This counter is used to find out the frequency of handover due to
UL quality on TCH/F channel. If the counter’s value is too large,
it indicates poor UL quality on TCH/F channel.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/F channel. If handover decision succeeds and the
handover is due to UL quality, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060085
Definition Number of TCH/F handover attempts due to DL quality
Description This counter counts the number of handover attempts due to DL
quality too poor on TCH/F channel.

Usage This counter is used to find out the frequency of handover due to
DL quality on TCH/F channel. If the counter’s value is too large,
it indicates poor DL quality on TCH/F channel.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/F channel. If handover decision succeeds and the
handover is due to DL quality, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060086
Definition Number of TCH/F handover attempts due to UL interference
Description This counter counts the number of handover attempts due to UL
interference too large on TCH/F channel.
Usage

178 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

This counter is used to find out the frequency of handover due to


UL interference on TCH/F channel. If the counter’s value is too
large, it indicates large UL interference on TCH/F channel.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/F channel. If handover decision succeeds and the
handover is due to UL interference, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060087
Definition Number of TCH/F handover attempts due to DL interference
Description This counter counts the number of handover attempts due to DL
interference too large on TCH/F channel.
Usage This counter is used to find out the frequency of handover due to
DL interference on TCH/F channel. If the counter’s value is too
large, it indicates large DL interference on TCH/F channel.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/F channel. If handover decision succeeds and the
handover is due to DL interference, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060088
Definition Number of TCH/F handover attempts due to good C/I
Description This counter counts the number of MS handover attempts due to
too large C/I ratio on TCH/F channel. The handover only occurs
during sub-cell configuration; when C/I algorithm is adopted, MS
performs handover from external circle to internal circle.
Usage This counter is used to find out the frequency of MS handover
due to too large C/I ratio on TCH/F channel. If the counter’s
value is too large, it indicates that, after MS accesses the
external circle, MS performs handover to the internal circle many
times due to good C/I ratio and the internal circle absorbs the
traffic.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/F channel. If handover decision succeeds and the
handover is due to too large C/I ratio, this counter increments.
The measurement point is A, as shown in Figure 124.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 179


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060089
Definition Number of TCH/F handover attempts due to bad C/I
Description This counter counts the number of MS handover attempts due to
too low C/I ratio on TCH/F channel. The handover only occurs
during sub-cell configuration; when C/I algorithm is adopted, MS
performs handover from internal circle to external circle.
Usage This counter is used to find out the frequency of MS handover
due to too low C/I ratio on TCH/F channel. If the counter’s value
is too large, it indicates that, when MS calls within the internal
circle, MS performs handover to the external circle many times
due to poor C/I ratio. Interference within the internal circle is big,
and C/I ratio of the internal circle can be improved by adjusting
the carrier power.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/F channel. If handover decision succeeds and the
handover is due to too low C/I ratio, this counter increments.
The measurement point is A, as shown in Figure 124.
Unit Times

C900060090
Definition Number of TCH/F handover attempts due to PBGT
Description This counter counts the number of MS handover attempts due to
PBGT value on TCH/F channel. If PBGT value is larger than zero,
it indicates the adjacent cell has better radio environment than
the current cell. If the number of times that PBGT value is larger
than zero reaches the threshold, PBGT handover occurs.
Usage This counter is used to find out the frequency of MS handover
due to PBGT value on TCH/F channel. If the counter’s value is
too large, it indicates that signal on TCH/F channel within the
current cell is poorer than that in the adjacent cell.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/F channel. If handover decision succeeds and the
handover is due to PBGT value, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060091
Definition Number of TCH/F handover attempts due to large TA
Description This counter counts the number of MS handover attempts due to
too large TA on TCH/F channel. Increasing TA indicates that MS

180 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

is moving away from the current cell. When the distance reaches
a certain value, handover will occur due to too large TA.
Usage This counter is used to find out the frequency of MS handover
due to too large TA on TCH/F channel. The counter’s value
reflects the mobility of subscribers in the current cell to a certain
extent.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/F channel. If handover decision succeeds and the
handover is due to too large TA, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060092
Definition Number of TCH/F handover attempts due to other reasons
Description This counter counts the number of handover attempts due to
any other reason beyond the handover reasons mentioned
previously.
Usage This counter is used to find out the frequency of handover due to
any other reason.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/F channel. If handover decision succeeds and the
handover is due to any other reason beyond the handover
reasons mentioned previously, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060093
Definition Number of BSC-controlled inter-cell outgoing handover
Description This counter counts the number of intra-BSC inter-cell handover-
out executions. The execution here means the radio resource of
target cell has been successfully requested, and system returns
the message of radio resource available.
Usage This counter is used to find out the frequency of intra-BSC inter-
cell outgoing handover execution. It is one of the parameters
that evaluate radio environment, and it reflects the handover
situation.
Measurement During the handover process, if the target cell requests for
Point channel successfully, it sends the message of radio resource
available back to the source cell. The source cell performs
judgment after receiving the message. If the request is due to
intra-BSC inter-cell handover, this counter increments. The
measurement point is A, as shown in Figure 125.

Confidential and Proprietary Information of ZTE CORPORATION 181


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 125 – BSC-CONTROLLED INTER-CELL OUTGOING HANDOVER


EXECUTION

MS BTS(Src) BTS(Target) BSC MSC


MEAS_RES
MEAS_RES

CHL_ACT
CHL_ACT_ACK

HO_CMD A
HO_CMD
HO_ACCESS
HO DETECT
Phy Info
SABM EST_IND
UA
HO_COM
HO_COM

HO_PERFORM

Unit Times

C900060094
Definition Number of BSC-controlled inter-cell outgoing handover success
Description This counter counts the number of successful intra-BSC inter-cell
outgoing handovers.
Usage This counter is used to find out the frequency of successful intra-
BSC inter-cell outgoing handover. It is one of the parameters
that evaluate the handover situation.
Measurement During the handover process, when the source cell receives the
Point handover completion message from the target cell, it indicates
that MS has accessed the target channel and handover succeeds.
In this case, this counter increments. The measurement point is
A, as shown in Figure 126.

182 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

FIGURE 126 – BSC-CONTROLLED INTER-CELL OUTGOING HANDOVER


SUCCESS

MS BTS(Src) BTS(Target) BSC MSC


MEAS_RES
MEAS_RES

CHL_ACT
CHL_ACT_ACK

HO_CMD
HO_CMD
HO_ACCESS
HO DETECT
Phy Info
SABM EST_IND
UA
HO_COM
HO_COM

A HO_PERFORM

Unit Times

C900060095
Definition Number of MSC-controlled outgoing handover
Description This counter counts the number of MSC-controlled inter-BSC
outgoing handover executions.
Usage This counter is used to find out the frequency of MSC-controlled
inter-BSC outgoing handover execution, and it reflects the
handover situation.
Measurement BSC performs handover decision after receiving MS
Point measurement report. If the handover decision indicates inter-cell
handover and the currently attempted cell is a cell under
another BSC, the source BSC sends the handover request
message A_HO_RQD to MSC to trigger inter-BSC handover. If
the source BSC receives the handover command returned from
MSC, the counter increments. The measurement point is A, as
shown in Figure 127.

FIGURE 127 – MSC-CONTROLLED OUTGOING HANDOVER EXECUTION

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 183


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060096
Definition Number of MSC-controlled outgoing handover success
Description This counter counts the number of successful MSC-controlled
inter-BSC outgoing handovers.
Usage This counter is used to find out the frequency of successful MSC-
controlled inter-BSC outgoing handover, and it reflects the
handover situation.
Measurement BSC performs handover decision after receiving MS
Point measurement report. If the handover decision indicates inter-cell
handover and the currently attempted cell is a cell under
another BSC, the source BSC sends the handover request
message A_HO_RQD to MSC to trigger inter-BSC handover. If
MS successfully accesses the target cell, the source cell receives
the release command issued by MSC. In this case, this counter
increments. The measurement point is A, as shown in Figure 128.

FIGURE 128 – MSC-CONTROLLED OUTGOING HANDOVER SUCCESS

Unit Times

C900060097
Definition Number of BSC-controlled inter-cell incoming handover
Description This counter counts the number of BSC-controlled inter-cell
incoming handover executions.
Usage This counter is used to find out the frequency of BSC-controlled
inter-cell incoming handover execution. It is one of the
parameters that evaluate radio environment, and it reflects the
handover situation.
Measurement If channel activation succeeds in the target cell within BSC and
Point the request is due to inter-cell handover, the counter increments.
The measurement point is A, as shown in Figure 129.

184 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

FIGURE 129 – BSC-CONTROLLED INTER-CELL INCOMING HANDOVER


EXECUTION

Unit Times

C900060098
Definition Number of BSC-controlled inter-cell incoming handover success
Description This counter counts the number of successful BSC-controlled
inter-cell incoming handovers.
Usage This counter shows the frequency of successful BSC-controlled
inter-cell incoming handover, and it reflects the handover
situation.
Measurement When the target cell within BSC receives the handover
Point completion message, if the request is due to BSC-controlled
inter-cell handover, the counter increments. The measurement
point is A, as shown in Figure 130.

FIGURE 130 – BSC-CONTROLLED INTER-CELL INCOMING HANDOVER


SUCCESS

BSC BTS

HO_ CMD

Unit Times

C900060099
Definition Number of MSC-controlled incoming handover
Description This counter counts the number of MSC-controlled inter-BSC
incoming handover executions.
Usage This counter is used to find out the frequency of MSC-controlled
inter-BSC incoming handover executions. It is one of the

Confidential and Proprietary Information of ZTE CORPORATION 185


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

parameters that evaluate radio environment, and it reflects the


handover situation.
Measurement After the target cell receives the handover request message
Point issued by MSC, the counter increments if the channel is
allocated and activated successfully. The measurement point is A,
as shown in Figure 131.

FIGURE 131 – MSC-CONTROLLED INCOMING HANDOVER EXECUTION

Unit Times

C900060100
Definition Number of MSC-controlled incoming handover due to forced
release
Description During MSC-controlled inter-BSC incoming handover process,
the counter counts the number of forced release executions due
to no available radio resource in the target cell.
Usage This counter is used to find out the frequency of forced release
executions during MSC-controlled inter-BSC incoming handover
process. It reflects the handover situation.
Measurement The target cell receives the radio channel request message. If
Point the request is due to MSC-controlled inter-BSC incoming
handover and the target cell has no available radio channels,
forced release is attempted. If the target cell receives the
message of resource available returned by the forced release
instance, the counter increments. The measurement point is A,
as shown in Figure 132.

186 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

FIGURE 132 – FORCED RELEASE EXECUTION

Unit Times

C900060101
Definition Number of MSC-controlled incoming handover due to queue
Description During MSC-controlled inter-BSC incoming handover process,
the counter counts the number of queuing executions due to no
available radio resource in the target cell.
Usage This counter is used to find out the frequency of queuing
executions during MSC-controlled inter-BSC incoming handover
process, and it reflects the handover situation.
Measurement The target cell receives the radio channel request message. If
Point the request is due to MSC-controlled inter-BSC incoming
handover and the target cell has no available radio channels, the
target instance is added to the waiting queue. When the target
cell receives the message of resource available, the counter
increments. The measurement point is A, as shown in Figure 133.

FIGURE 133 – QUEUING EXECUTION

Unit Times

C900060102
Definition Number of MSC-controlled incoming handover success

Confidential and Proprietary Information of ZTE CORPORATION 187


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Description This counter counts the number of successful MSC-controlled


inter-BSC incoming handovers.
Usage This counter is used to find out the frequency of successful MSC-
controlled inter-BSC incoming handover, and it reflects the
handover situation.
Measurement When the target cell receives the handover completion message,
Point if the request is due to MSC-controlled inter-BSC incoming
handover, the counter increments. The measurement point is A,
as shown in Figure 134.

FIGURE 134 – MSC-CONTROLLED INCOMING HANDOVER SUCCESS

Unit Times

C900060103
Definition Number of incoming handover from undefined layer (GSM900)
to current layer(GSM1800)
Description This counter counts the number of incoming handover
executions from the undefined layer cell (GSM900) to the target
cell (GSM1800) during BSC-controlled inter-cell handover.
Usage This counter is used to find out the frequency of incoming
handover executions from the undefined layer cell (GSM900) to
target cell (GSM1800). It reflects the handover situation.
Measurement When the target cell (GSM1800) within BSC receives the channel
Point activation response message, if the request is due to BSC-
controlled inter-cell handover and the source cell (GSM900) is
the undefined layer cell, the counter increments. The
measurement point is A, as shown in Figure 129.
Unit Times

C900060104
Definition Number of incoming handover success from undefined
layer(GSM900) to current layer (GSM1800)
Description This counter counts the number of successful incoming handover
from the undefined layer cell (GSM900) to the target cell
(GSM1800) during BSC-controlled inter-cell handover.

188 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Usage This counter is used to find out the frequency of successful


incoming handover from the undefined layer cell (GSM900) to
the target cell (GSM1800). It reflects the handover situation.
Measurement When the target cell (GSM1800) within BSC receives the
Point handover completion message, if the request is due to BSC-
controlled inter-cell handover and the source cell (GSM900) is
the undefined layer cell, the counter increments. The
measurement point is A, as shown in Figure 130.
Unit Times

C900060105
Definition Number of incoming handover from undefined layer (GSM1800)
to current layer (GSM900)
Description This counter counts the number of incoming handover
executions from the undefined layer cell (GSM1800) to the
target cell (GSM900) during BSC-controlled inter-cell handover.
Usage This counter is used to find out the frequency of incoming
handover executions from the undefined layer cell (GSM1800) to
target cell (GSM900). It reflects the handover situation.
Measurement When the target cell (GSM900) within BSC receives the channel
Point activation response message, if the request is due to BSC-
controlled inter-cell handover and the source cell (GSM1800) is
the undefined layer cell, the counter increments. The
measurement point is A, as shown in Figure 129.
Unit Times

C900060106
Definition Number of incoming handover success from undefined
layer(GSM1800) to current layer(GSM900)
Description This counter counts the number of successful incoming handover
from the undefined layer cell (GSM1800) to the target cell
(GSM900) during BSC-controlled inter-cell handover.
Usage This counter is used to find out the frequency of successful
incoming handover from the undefined layer cell (GSM1800) to
the target cell (GSM900). It reflects the handover situation.
Measurement When the target cell (GSM900) within BSC receives the
Point handover completion message, if the request is due to BSC-
controlled inter-cell handover and the source cell (GSM1800) is
the undefined layer cell, the counter increments. The
measurement point is A, as shown in Figure 130.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 189


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060107
Definition Number of incoming handover from the same layer GSM900 to
GSM1800
Description This counter counts the number of incoming handover
executions from the cell (GSM900) to the target cell (GSM1800)
in the same layer during BSC-controlled inter-cell handover.
Usage This counter is used to find out the frequency of incoming
handover executions from the cell (GSM900) to the target cell
(GSM1800) in the same layer. It reflects the handover situation.
Measurement When the target cell (GSM1800) receives the channel activation
Point response message, if the request is due to BSC-controlled inter-
cell handover and the source cell (GSM900) is in the same layer,
the counter increments. The measurement point is A, as shown
in Figure 129.
Unit Times

C900060108
Definition Number of incoming handover success from the same layer
GSM900 to GSM1800
Description This counter counts the number of successful incoming
handovers from the cell (GSM900) to the target cell (GSM1800)
in the same layer during BSC-controlled inter-cell handover.
Usage This counter is used to find out the frequency of successful
incoming handover from the cell (GSM900) to the target cell
(GSM1800) in the same layer. It reflects the handover situation.
Measurement When the target cell (GSM1800) receives the handover
Point completion message, if the request is due to BSC-controlled
inter-cell handover and the source cell (GSM900) is in the same
layer, the counter increments. The measurement point is A, as
shown in Figure 130.
Unit Times

C900060109
Definition Number of incoming handover from GSM900 to GSM1800 from
the upper layer
Description This counter counts the number of incoming handover
executions from the upper layer cell (GSM900) to the target cell
(GSM1800) during BSC-controlled inter-cell handover.
Usage

190 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

This counter is used to find out the frequency of incoming


handover executions from the upper layer cell (GSM900) to the
target cell (GSM1800). It reflects the handover situation.
Measurement When the target cell (GSM1800) receives the channel activation
Point response message, if the request is due to BSC-controlled inter-
cell handover and the source cell (GSM900) is in the upper layer,
the counter increments. The measurement point is A, as shown
in Figure 129.
Unit Times

C900060110
Definition Number of incoming handover success from GSM900 to
GSM1800 in the upper layer
Description This counter counts the number of successful incoming
handovers from the upper layer cell (GSM900) to the target cell
(GSM1800) during BSC-controlled inter-cell handover.

Usage This counter is used to find out the frequency of successful


incoming handover from the upper layer cell (GSM900) to the
target cell (GSM1800). It reflects the handover situation.
Measurement When the target cell (GSM1800) receives the handover
Point completion message, if the request is due to BSC-controlled
inter-cell handover and the source cell (GSM900) is in the upper
layer, the counter increments. The measurement point is A, as
shown in Figure 130.
Unit Times

C900060111
Definition Number of incoming handover from GSM900 to GSM1800 in the
lower layer
Description This counter counts the number of incoming handover
executions from the lower layer cell (GSM900) to the target cell
(GSM1800) during BSC-controlled inter-cell handover.
Usage This counter is used to find out the frequency of incoming
handover executions from the lower layer cell (GSM900) to the
target cell (GSM1800). It reflects the handover situation.
Measurement When the target cell (GSM1800) receives the channel activation
Point response message, if the request is due to BSC-controlled inter-
cell handover and the source cell (GSM900) is in the lower layer,
the counter increments. The measurement point is A, as shown
in Figure 129.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 191


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060112
Definition Number of incoming handover success from GSM900 to
GSM1800 in the lower layer
Description This counter counts the number of successful incoming
handovers from the lower layer cell (GSM900) to the target cell
(GSM1800) during BSC-controlled inter-cell handover.
Usage This counter is used to find out the frequency of successful
incoming handover from the lower layer cell (GSM900) to the
target cell (GSM1800). It reflects the handover situation.
Measurement When the target cell (GSM1800) receives the handover
Point completion message, if the request is due to BSC-controlled
inter-cell handover and the source cell (GSM900) is in the lower
layer, the counter increments. The measurement point is A, as
shown in Figure 130.
Unit Times

C900060113
Definition Number of incoming handover from GSM1800 to GSM900 from
the same layer
Description This counter counts the number of incoming handover
executions from the cell (GSM1800) to the target cell (GSM900)
in the same layer during BSC-controlled inter-cell handover.
Usage This counter is used to find out the frequency of incoming
handover executions from the cell (GSM1800) to the target cell
(GSM900) in the same layer. It reflects the handover situation.
Measurement When the target cell (GSM900) receives the channel activation
Point response message, if the request is due to BSC-controlled inter-
cell handover and the source cell (GSM1800) is in the same
layer, the counter increments. The measurement point is A, as
shown in Figure 129.
Unit Times

C900060114
Definition Number of incoming handover success from GSM1800 to
GSM900 from the same layer
Description This counter counts the number of successful incoming
handovers from the cell (GSM1800) to the target cell (GSM900)
in the same layer during BSC-controlled inter-cell handover.
Usage

192 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

This counter is used to find out the frequency of successful


incoming handover from the cell (GSM1800) to the target cell
(GSM900) in the same layer. It reflects the handover situation.
Measurement When the target cell (GSM900) receives the handover
Point completion message, if the request is due to BSC-controlled
inter-cell handover and the source cell (GSM1800) is in the same
layer, the counter increments. The measurement point is A, as
shown in Figure 130.
Unit Times

C900060115
Definition Number of incoming handover from GSM1800 to GSM900 from
the upper layer
Description This counter counts the number of incoming handover
executions from the upper layer cell (GSM1800) to the target
cell (GSM900) during BSC-controlled inter-cell handover.
Usage This counter is used to find out the frequency of incoming
handover executions from the upper layer cell (GSM1800) to the
target cell (GSM900). It reflects the handover situation.
Measurement When the target cell (GSM900) receives the channel activation
Point response message, if the request is due to BSC-controlled inter-
cell handover and the source cell (GSM1800) is in the upper
layer, the counter increments. The measurement point is A, as
shown in Figure 129.
Unit Times

C900060116
Definition Number of incoming handover success from GSM1800 to
GSM900 from the upper layer
Description This counter counts the number of successful incoming
handovers from the upper layer cell (GSM1800) to the target cell
(GSM900) during BSC-controlled inter-cell handover.
Usage This counter is used to find out the frequency of successful
incoming handover from the upper layer cell (GSM1800) to the
target cell (GSM900). It reflects the handover situation.
Measurement When the target cell (GSM900) receives the handover
Point completion message, if the request is due to BSC-controlled
inter-cell handover and the source cell (GSM1800) is in the
upper layer, the counter increments. The measurement point is
A, as shown in Figure 130.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 193


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060117
Definition Number of incoming handover from GSM1800 to GSM900 from
the lower layer
Description This counter counts the number of incoming handover
executions from the lower layer cell (GSM1800) to the target cell
(GSM1800) during BSC-controlled inter-cell handover.
Usage This counter is used to find out the frequency of incoming
handover executions from the lower layer cell (GSM1800) to the
target cell (GSM1800). It reflects the handover situation.
Measurement When the target cell (GSM900) receives the channel activation
Point response message, if the request is due to BSC-controlled inter-
cell handover and the source cell (GSM1800) is in the lower
layer, the counter increments. The measurement point is A, as
shown in Figure 129.
Unit Times

C900060118
Definition Number of incoming handover success from GSM1800 to
GSM900 from the lower layer
Description This counter counts the number of successful incoming
handovers from the lower layer cell (GSM1800) to the target cell
(GSM900) during BSC-controlled inter-cell handover.

Usage This counter is used to find out the frequency of successful


incoming handover from the lower layer cell (GSM1800) to the
target cell (GSM900). It reflects the handover situation.
Measurement When the target cell (GSM900) receives the handover
Point completion message, if the request is due to BSC-controlled
inter-cell handover and the source cell (GSM1800) is in the
lower layer, the counter increments. The measurement point is A,
as shown in Figure 130.
Unit Times

C900060119
Definition Number of Intra-cell handover
Description This counter counts the number of intra-cell handover
executions which is initiated by MS in the source cell. Here, the
execution means that radio resource is requested successfully
and the message of resource available is returned.

194 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Usage This counter is used to find out the frequency of MS-initiated


intra-cell handover execution. It is one of the parameters that
evaluate radio environment. It reflects the handover situation.
Measurement During the handover process, if the target channel request
Point succeeds, the message of radio resource available is returned to
BSC. BSC then performs judgment after receiving the message.
If the request is due to intra-cell handover, this counter
increments. The measurement point is A, as shown in Figure 135.

FIGURE 135 – INTRA-CELL HANDOVER EXECUTION

Unit Times

C900060120
Definition Number of Intra-cell handover success
Description This counter counts the number of successful intra-cell
handovers which are initiated by MS in the source cell.
Usage This counter is used to find out the frequency of successful intra-
cell handover. It is one of the parameters that evaluate
handover.
Measurement During the intra-cell handover process, if the source instance
Point receives the handover completion message returned by the
target instance, it indicates MS accesses the target channel and
handover succeeds. In this case, this counter increments. The
measurement point is A, as shown in Figure 136.

FIGURE 136 – INTRA-CELL HANDOVER SUCCESS

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 195


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060121
Definition Maximum number of busy TCH/H
Description This counter counts the maximum number of occupied TCH/Hs
in a cell during a measurement period.
The system records the TCH/Hs occupied in the cell. If a TCH/H
is successfully occupied, the number of occupied TCH/Hs
increases by 1; if a TCH/H is released, the number of occupied
TCH/Hs decreases by 1. After a TCH/H is occupied, before a
TCH/H is released, or when the system reports the periodical
measurement data, if this counter’s value is less than the
number of actual occupied TCH/Hs, this counter’s value will be
replaced by the actual number of occupied TCH/Hs.
In consideration of the TCH/H channel occupation situation in
the last measurement period, the number of occupied TCH/Hs is
updated before the release of a TCH/H.
Usage This counter is used to find out the maximum number of
occupied TCH/Hs in a cell during a measurement period. The
counter’s value reflects the instantaneous occupation and the
heaviest traffic of TCH/H.
Measurement The counter counts at the following three time points:
Point
„ After the TCH/H is occupied successfully, if the maximum
number of busy TCH/Hs exceeds the counter’s recorded
value;
„ Before the TCH/H is released, if the maximum number of
busy TCH/Hs exceeds the counter’s recorded value;
„ When the system reports the periodical measurement data, if
the maximum number of busy TCH/Hs exceeds the counter’s
recorded value.
The measurement point is A, as shown in Figure 137.

FIGURE 137 – REPORTING MEASUREMENT DAT A

BSC OMCR

Measurement Data

Unit Times

196 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

C900060122
Definition Average number of available SDCCH
Description This counter counts the number of SDCCHs which can be
assigned normally, including idle SDCCH and occupied SDCCH.
Usage This counter is used to find out the number of available SDCCHs
in the current cell.
Measurement Query the database when periodic measurement data is reported
Point to get the value of the counter. The measurement point is A, as
shown in Figure 137.
Unit Times

C900060123
Definition Average number of unavailable SDCCH
Description This counter counts the number of SDCCHs that can not be
assigned normally, including those SDCCHs blocked due to
various reasons.
Usage This counter is used to find out the number of unavailable
SDCCHs to facilitate troubleshooting.
Measurement Query the database when periodic measurement data is reported
Point to get the value of the counter. The measurement point is A, as
shown in Figure 137.
Unit Times

C900060124
Definition SDCCH busy time
Description This counter counts the busy time of SDCCHs, which reflects the
traffic volume of SDCCH.

Usage This counter is used to find out the busy level and the average
occupation time of the signaling channel. It can be used as a
reference for judging whether to increase the number of SDCCHs.
Measurement The counter counts at the following three time points:
Point
„ When an SDCCH is acquired successfully, this counter
calculates time and accumulates.
„ When an SDCCH is released, this counter calculates time and
accumulates.
„ When the system reports the periodical measurement data,
this counter calculates time and accumulates.

Confidential and Proprietary Information of ZTE CORPORATION 197


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

The measurement point is A, as shown in Figure 137.


„ The measurement formula is as follows:
„ Measurement value = (Current time – Last measurement
time point) × Number of MSs that are occupying the
channels
„ The reported measurement value is accumulated by each
measurement value. After each accumulation, the last
measurement time point is updated to the current time. If an
SDCCH is acquired successfully, Number of MSs that are
occupying the channels increases by 1; if an SDCCH is
released, Number of MSs that are occupying the
channels decreases by 1.
Unit Second

C900060125
Definition Average number of available radio channel
Description This counter counts the number of radio channel which can be
assigned normally, including idle radio channel and occupied
radio channel.
Usage This counter is used to find out the number of available radio
channel in the current cell. It helps understand the current
resource usage situation of the cell.
Measurement Query the database when periodic measurement data is reported
Point to get the value of the counter. The measurement point is A, as
shown in Figure 137.
Unit Times

C900060126
Definition Average number of unavailable radio channel
Description This counter counts the number of radio channels that can not
be assigned normally, including those radio channels blocked
due to various reasons.

Usage This counter is used to find out the number of unavailable radio
channels in the current cell. It helps understand the current
resource usage situation of the cell.
Measurement Query the database when periodic measurement data is reported
Point to get the value of the counter. The measurement point is A, as
shown in Figure 137.
Unit Times

198 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

C900060127
Definition TCH/H busy time
Description This counter counts the busy time of TCH/Hs, which reflects the
traffic volume of TCH/H.
Usage This counter is used to find out the busy level and the average
occupation time of TCH/H. It can be used as a reference for
judging whether to increase the number of TCH/Hs.
Measurement The counter counts at the following three time points:
Point
„ When a TCH/H is acquired successfully, this counter
calculates time and accumulates.
„ When a TCH/H is released, this counter calculates time and
accumulates.
„ When the system reports the periodical measurement data,
this counter calculates time and accumulates.
The measurement point is A, as shown in Figure 137.
„ The measurement formula is as follows:
„ Measurement value = (Current time – Last measurement
time point) × Number of MSs that are occupying the
channels
„ The reported measurement value is accumulated by each
measurement value. After each accumulation, the last
measurement time point is updated to the current time. If a
TCH/H is acquired successfully, Number of MSs that are
occupying the channels increases by 1; if a TCH/H is
released, Number of MSs that are occupying the
channels decreases by 1.
Unit Second

C900060128
Definition Maximum number of busy TCH/F
Description This counter counts the maximum number of occupied TCH/Fs in
a cell during a measurement period.
The system records the TCH/Fs occupied in the cell. If a TCH/F is
successfully occupied, the number of occupied TCH/Fs increases
by 1; if a TCH/F is released, the number of occupied TCH/Hs
decreases by 1. After a TCH/F is occupied, before a TCH/F is
released, or when the system reports the periodical
measurement data, if this counter’s value is less than the
number of actual occupied TCH/Fs, this counter’s value will be
replaced by the actual number of occupied TCH/Fs.

Confidential and Proprietary Information of ZTE CORPORATION 199


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

In consideration of the TCH/F channel occupation situation in the


last measurement period, the number of occupied TCH/Fs is
updated before the release of a TCH/F.
Usage This counter is used to find out the maximum number of
occupied TCH/Fs in a cell during a measurement period. The
counter’s value reflects the instantaneous occupation and the
heaviest traffic of TCH/F.
Measurement The counter counts at the following three time points:
Point
„ After the TCH/F is occupied successfully, if the maximum
number of busy TCH/Fs exceeds the counter’s recorded value;
„ Before the TCH/F is released, if the maximum number of
busy TCH/Hs exceeds the counter’s recorded value;
„ When the system reports the periodical measurement data, if
the maximum number of busy TCH/Fs exceeds the counter’s
recorded value.
The measurement point is A, as shown in Figure 137.
Unit Times

C900060129
Definition TCH/F busy time
Description This counter counts the busy time of TCH/Fs, which reflects the
traffic volume of TCH/F.
Usage This counter is used to find out the busy level and the average
occupation time of TCH/F. It can be used as a reference for
judging whether to increase the number of TCH/Fs.
Measurement The counter counts at the following three time points:
Point
„ When a TCH/F is acquired successfully, this counter
calculates time and accumulates.
„ When a TCH/F is released, this counter calculates time and
accumulates.
„ When the system reports the periodical measurement data,
this counter calculates time and accumulates.
The measurement point is A, as shown in Figure 137.
„ The measurement formula is as follows:
„ Measurement value = (Current time – Last measurement
time point) × Number of MSs that are occupying the
channels
„ The reported measurement value is accumulated by each
measurement value. After each accumulation, the last
measurement time point is updated to the current time. If a
TCH/F is acquired successfully, Number of MSs that are
occupying the channels increases by 1; if a TCH/F is

200 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

released, Number of MSs that are occupying the


channels decreases by 1.
Unit Second

C900060130
Definition Number of healthy TRXs
Description This counter counts the number of the TRXs that can be used
normally.
Usage This counter is used to find out the number of available TRXs
and resource usage in the current cell to facilitate
troubleshooting.
Measurement Query the database when periodic measurement data is reported
Point to get the value of the counter. The measurement point is A, as
shown in Figure 137.
Unit Times

C900060131
Definition Number of CM service requests of MOC
Description This counter counts the number of accesses due to CM SERVICE
REQ of MOC. After BSC receives the EST_IND message, if the
access cause in the layer-3 information in this message is “CM
SERVICE REQ”, this counter increments.
Usage This counter is used to find out the frequency of the access due
to CM SERVICE REQ of MOC.
Measurement This counter counts when BSC receives the EST_IND message.
Point The measurement point is A4, as shown in Figure 99.
Unit Times

C900060132
Definition Number of SAPI3 link establishment success on SDCCH (MT-SM)
Description This counter counts the number of successful short message link
establishment of mobile terminating call on SDCCH. On SDCCH,
if BSC receives the EST_CONF message sent by BTS after BSC
initiates the short message link establishment flow, it indicates
this link establishment succeeds, and the counter increments.
Usage This counter is used to find out the frequency of successful SAPI
3 link establishments on SDCCH.

Confidential and Proprietary Information of ZTE CORPORATION 201


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Measurement This counter counts when BSC receives the EST_CONF message
Point (SAPI = 3) from BTS. The measurement point is D2, as shown in
Figure 121.
Unit
Times

C900060133
Definition Number of available defined SDCCH
Description iBSC supports dynamic conversion of SDCCH and TCH. This
counter counts the number of available SDCCH configured by
OMCR in the current cell.
Usage This counter is used to find out the number of available SDCCH
in the current cell to facilitate eliminating fault in the cell.
Measurement Query the database when periodic measurement data is reported
Point to get the value of the counter. The measurement point is A, as
shown in Figure 137.
Unit Times

C900060134
Definition Number of available defined TCH/F
Description iBSC supports the function of full dynamic radio channel. This
counter counts the number of available TCH/F configured by
OMCR in the current cell.
Usage This counter is used to find out the number of available TCH/F in
the current cell to facilitate eliminating fault in the cell.
Measurement Query the database when periodic measurement data is reported
Point to get the value of the counter. The measurement point is A, as
shown in Figure 137.
Unit Times

C900060135
Definition Number of signaling TCH/H assignment failure
Description This counter counts the number of failing to assign TCH/H
channel as a signaling channel.
Usage After BSC responds to the channel request message to allocate
and occupy TCH/H successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/H. If BSC does not receive
the MS access notification within a certain time, this assignment
fails.

202 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Measurement For immediate assignment, this counter counts when BSC


Point receives incorrect EST_IND message or T3101 is timeout. The
measurement point is A3, as shown in Figure 103.
Unit Times

C900060136
Definition Number of MOC access attempts
Description This counter counts the number of channel requests due to
Mobile Originated Call (MOC). When MS sends the CHL_REQ
message through BTS to BSC to request for radio channel, if TA
does not exceed the cell range and the access cause is ‘MOC’,
this counter increments.
Usage This counter is used to find out the frequency of channel
requests due to the access cause ‘MOC’.
Measurement This counter counts when MS requests for channel from BSC and
Point TA does not exceed the cell range. The measurement point is A1,
as shown in Figure 99.
Unit Times

C900060137
Definition Number of wireless access due to paging responses
Description This counter counts the number of accesses due to paging
responses. After BSC receives the EST_IND message, if the
access cause in the layer-3 information in this message is
‘paging responses’, this counter increments.
Usage This counter is used to find out the frequency of the access due
to paging responses.
Measurement This counter counts when BSC receives the EST_IND message.
Point The measurement point is A4, as shown in Figure 99.
Unit Times

C900060138
Definition Number of TCH/F allocation failure due to BTS connection failure
for assignment (speech version1)
Description This counter counts the number of failing to allocate TCH/F
channel due to BTS connection failure when assigning voice
channel (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CMM

Confidential and Proprietary Information of ZTE CORPORATION 203


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

connection request to BTS. If BTS connection fails due to


receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during CMM
connection process. The measurement point is B2, as shown in
Figure 138.

FIGURE 138 – COMMON ASSIGNMENT FLOW 3 (TC IS INTERNAL)

Unit Times

C900060139
Definition Number of TCH/F allocation failure due to BIU connection failure
for assignment (speech version1)
Description This counter counts the number of failing to allocate TCH/F
channel due to BIU connection failure when assigning voice
channel (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during BIU
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060140
Definition Number of TCH/F allocation failure due to TCU connection failure
for assignment (speech version1)

204 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Description This counter counts the number of failing to allocate TCH/F


channel due to TCU connection failure when assigning voice
channel (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during TCU
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060141
Definition Number of TCH/F allocation failure due to channel activation
failure for assignment (speech version2)
Description This counter counts the number of TCH/F channel allocation
failure due to channel activation failure when assigning speech
channel (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/F. If the channel activation
fails due to receiving channel activation failure message,
incorrect channel activation response message, T9103 timeout,
channel instance being released or channel being released
forcibly, this counter accumulates.
Measurement BSC activates TCH/F as voice channel (using speech version 2)
Point for assignment, but the problem such as receiving channel
activation failure message, incorrect channel activation response
message, T9103 timeout, channel instance being released, or
channel being forcibly released occurs. The measurement point
is B3, as shown in Figure 118.
Unit Times

C900060142
Definition Number of TCH/F allocation failure due to BTS connection failure
for assignment (speech version2)
Description This counter counts the number of failing to allocate TCH/F
channel due to BTS connection failure when assigning voice
channel (using speech version 2).

Confidential and Proprietary Information of ZTE CORPORATION 205


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

After BSC responds to the channel request message to allocate


and occupy TCH/F channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during CMM
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060143
Definition Number of TCH/F allocation failure due to BIU connection failure
for assignment (speech version2)
Description This counter counts the number of failing to allocate TCH/F
channel due to BIU connection failure when assigning voice
channel (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during BIU
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060144
Definition Number of TCH/F allocation failure due to TCU connection failure
for assignment (speech version2)
Description This counter counts the number of failing to allocate TCH/F
channel due to TCU connection failure when assigning voice
channel (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.

206 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Measurement BSC uses TCH/F for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during TCU
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060145
Definition Number of TCH/F allocation failure due to BTS connection failure
for assignment (speech version3)
Description This counter counts the number of failing to allocate TCH/F
channel due to BTS connection failure when assigning voice
channel (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during CMM
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060146
Definition Number of TCH/F allocation failure due to BIU connection failure
for assignment (speech version3)
Description This counter counts the number of failing to allocate TCH/F
channel due to BIU connection failure when assigning voice
channel (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during BIU
connection process. The measurement point is B2, as shown in
Figure 138.

Confidential and Proprietary Information of ZTE CORPORATION 207


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Unit Times

C900060147
Definition Number of TCH/F allocation failure due to TCU connection failure
for assignment (speech version3)
Description This counter counts the number of failing to allocate TCH/F
channel due to TCU connection failure when assigning voice
channel (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during TCU
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060148
Definition Number of TCH/F allocation failure due to BTS connection failure
for assignment (speech version3)
Description This counter counts the number of failing to allocate TCH/F
channel due to BTS connection failure when assigning data
channel.
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message or timer timeout occurs during CMM
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

208 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

C900060149
Definition Number of data TCH/F allocation failure due to BIU connection
failure for assignment
Description This counter counts the number of failing to allocate TCH/F
channel due to BIU connection failure when assigning data
channel.
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for assignment, but receives connection failure
Point message, incorrect connection response message or timer
timeout during BIU connection process. The measurement point
is B2, as shown in Figure 138.
Unit Times

C900060150
Definition Number of data TCH/F allocation failure due to TCU connection
failure for assignment
Description This counter counts the number of failing to allocate TCH/F
channel due to TCU connection failure when assigning data
channel.
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for assignment, but receiving connection failure
Point message, incorrect connection response message or timer
timeout during TCU connection process. The measurement point
is B2, as shown in Figure 138.
Unit Times

C900060151
Definition Number of voice TCH/H drops due to handover failure
Description This counter counts the number of call drops due to handover
failure on TCH/H voice channel. Call drop occurs after MS

Confidential and Proprietary Information of ZTE CORPORATION 209


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

requests for TCH/H voice channel successfully. If the problem is


due to handover failure, the counter increments.
Presently, reasons for handover failure include T3107 timeout,
T3103 timeout and external handover timer timeout under the
status of ASSIGNING.
Usage This counter is used to find out the frequency of call drop due to
handover failure on TCH/H voice channel.
Measurement TCH/H voice channel is activated after BSC initiates the
Point handover flow. After that:
„ If RANCS is in the status of RADIO_APPLY and sends the
intra-cell handover command, then T3107 is started. If
RANCS is in the status of ASSIGN and T3107 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 122.
„ If RANCS is in the status of RADIO_APPLY and sends the
inter-cell handover command, then T3103 is started. If
RANCS is in the status of ASSIGN and T3103 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 123.
„ If RANCS is in the status of RADIO_APPLY and sends the
external handover command, then the external handover
timer is started. If RANCS is in the status of ASSIGN and the
external handover timer is timeout, then the counter
increments. The measurement point is A1, as shown in
Figure 145.
Unit Times

C900060152
Definition Number of Abis interface paging command messages
Description This counter counts the number of paging command messages
from A-interface. These messages are part of Abis interface
messages sent from BSC.
Usage This counter is used to find out the frequency of transmitting
paging command messages at Abis interface. These messages
are from A-interface.
Measurement When BSC sends ABIS_INTER_PAGING_CMD message to BTS,
Point this counter increments. The measurement point is A, as shown
in Figure 139.

210 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

FIGURE 139 – MEASUREMENT POINT OF NUMBER OF ABIS INTERFACE


MESSAGES SENT TO BTS FROM BSC

Unit Times

C900060153
Definition Number of Abis CS paging messages
Description This counter counts the number of CS paging command
messages from Gb interface. These messages are part of Abis
interface messages sent from BSC.

Usage This counter is used to find out the frequency of transmitting CS


paging command messages at Abis interface. These messages
are from Gb interface.
Measurement When BSC sends ABIS_INTER_CSPAGING_CMD message to BTS,
Point this counter increments. The measurement point is A, as shown
in Figure 139.
Unit Times

C900060154
Definition Number of Abis PS paging messages
Description This counter counts the number of PS paging command
messages from Gb interface. These messages are part of Abis
interface messages sent from BSC.
Usage This counter is used to find out the frequency of transmitting PS
paging command messages at Abis interface. These messages
are from Gb interface.
Measurement When BSC sends ABIS_INTER_PSPAGING_CMD message to BTS,
Point this counter increments. The measurement point is A, as shown
in Figure 139.
Unit Times

C900060155
Definition Number of available defined TCH/H

Confidential and Proprietary Information of ZTE CORPORATION 211


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Description iBSC supports the function of full dynamic radio channel. This
counter counts the number of available TCH/H channel
configured by OMCR in the current cell.
Usage This counter is used to find out the number of available TCH/H
channel in the current cell to eliminate the fault in the cell.
Measurement Query the database when periodic measurement data is reported
Point to get the value of the counter. The measurement point is A, as
shown in Figure 137.
Unit Times

C900060156
Definition Number of TCH/F allocation failure due to channel activation
failure for handover(speech version1)
Description This counter counts the number of failing to allocate TCH/F
channel due to channel activation failure during voice channel
handover (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, if the connection
succeeds, BSC sends the channel activation message CHL_ACT
to BTS to activate this TCH/F. If channel activation fails due to
receiving channel activation failure message, incorrect channel
activation response message, T9103 being timeout, channel
instance being released or channel being forcibly released, this
counter accumulates.
Measurement BSC activates TCH/F channel as voice channel due to handover,
Point but receives channel activation failure message, incorrect
channel activation response message, T9103 being timeout,
channel instance being released, or channel being forcibly
released. The measurement point is C3 as shown in Figure 112
and D3 as shown in Figure 113.
Unit Times

C900060157
Definition Number of TCH/F allocation failure due to BTS connection failure
for handover (speech version1)
Description This counter counts the number of failing to allocate TCH/F
channel due to BTS connection failure during voice channel
handover (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM

212 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

connection response message, or timer timeout, this counter


accumulates.
Measurement BSC uses TCH/F channel for handover, but receives connection
Point failure message, incorrect connection response message, or
timer timeout during CMM connection process. The
measurement point is C2 as shown in Figure 140 and D2 as
shown in Figure 141.

FIGURE 140 – INTERNAL HANDOVER FAILURE FLOW 2 (INTRA-CELL


HANDOVER, TC IS INTERNAL)

FIGURE 141 – EXTERNAL HANDOVER FAILURE FLOW 3 (TC IS INTERNAL)

Unit Times

C900060158
Definition Number of TCH/F allocation failure due to BIU connection failure
for handover (speech version1)
Description This counter counts the number of failing to allocate TCH/F
channel due to BIU connection failure during voice channel
handover (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message or timer timeout, this counter
accumulates.

Confidential and Proprietary Information of ZTE CORPORATION 213


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Measurement BSC uses TCH/F for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during BIU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060159
Definition Number of TCH/F allocation failure due to TCU connection failure
for handover (speech version1)
Description This counter counts the number of failing to allocate TCH/F
channel due to TCU connection failure during voice channel
handover (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during TCU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060160
Definition Number of TCH/F allocation failure due to channel activation
failure for handover(speech version2)
Description This counter counts the number of failing to allocate TCH/F
channel due to channel activation failure during voice channel
handover (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, if the connection
succeeds, BSC sends the channel activation message CHL_ACT
to BTS to activate this TCH/F. If channel activation fails due to
receiving channel activation failure message, incorrect channel
activation response message, T9103 being timeout, channel
instance being released or channel being forcibly released, this
counter accumulates.
Measurement BSC activates TCH/F channel as voice channel due to handover,
Point but receives channel activation failure message, incorrect
channel activation response message, T9103 being timeout,
channel instance being released, or channel being forcibly
released. The measurement point is C3 as shown in Figure 112
and D3 as shown in Figure 113.

214 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Unit Times

C900060161
Definition Number of TCH/F allocation failure due to BTS connection failure
for handover (speech version2)
Description This counter counts the number of failing to allocate TCH/F
channel due to BTS connection failure during voice channel
handover (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F channel for handover, but receives connection
Point failure message, incorrect connection response message, or
timer timeout during CMM connection process. The
measurement point is C2 as shown in Figure 140 and D2 as
shown in Figure 141.
Unit Times

C900060162
Definition Number of TCH/F allocation failure due to BIU connection failure
for handover (speech version2)
Description This counter counts the number of failing to allocate TCH/F
channel due to BIU connection failure during voice channel
handover (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during BIU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060163
Definition

Confidential and Proprietary Information of ZTE CORPORATION 215


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Number of TCH/F allocation failure due to TCU connection failure


for handover (speech version2)
Description This counter counts the number of failing to allocate TCH/F
channel due to TCU connection failure during voice channel
handover (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during TCU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060164
Definition Number of TCH/F allocation failure due to channel activation
failure for handover(speech version3)
Description This counter counts the number of failing to allocate TCH/F
channel due to channel activation failure during voice channel
handover (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, if the connection
succeeds, BSC sends the channel activation message CHL_ACT
to BTS to activate this TCH/F. If channel activation fails due to
receiving channel activation failure message, incorrect channel
activation response message, T9103 being timeout, channel
instance being released or channel being forcibly released, this
counter accumulates.
Measurement BSC activates TCH/F channel as voice channel due to handover,
Point but receives channel activation failure message, incorrect
channel activation response message, T9103 being timeout,
channel instance being released, or channel being forcibly
released. The measurement point is C3 as shown in Figure 112
and D3 as shown in Figure 113.
Unit Times

C900060165
Definition Number of TCH/F allocation failure due to BTS connection failure
for handover (speech version3)
Description

216 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

This counter counts the number of failing to allocate TCH/F


channel due to BTS connection failure during voice channel
handover (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F channel for handover, but receives connection
Point failure message, incorrect connection response message, or
timer timeout during CMM connection process. The
measurement point is C2 as shown in Figure 140 and D2 as
shown in Figure 141.
Unit Times

C900060166
Definition Number of TCH/F allocation failure due to BIU connection failure
for handover (speech version3)
Description This counter counts the number of failing to allocate TCH/F
channel due to BIU connection failure during voice channel
handover (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during BIU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060167
Definition Number of TCH/F allocation failure due to TCU connection failure
for handover (speech version3)
Description This counter counts the number of failing to allocate TCH/F
channel due to TCU connection failure during voice channel
handover (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to

Confidential and Proprietary Information of ZTE CORPORATION 217


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

receiving TCU connection failure message, incorrect TCU


connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during TCU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060168
Definition Number of Voice TCH/F handover success
Description This counter counts the number of successful TCH/F channel
handover during voice channel handover.
When BSC detects the successful handover message sent by MS
on newly-allocated TCH/F channel, this counter accumulates.
The ASS_COM message indicates successful intra-cell handover,
and the HO_COM message indicates successful inter-cell
handover and external handover.
For intra-cell handover and inter-cell handover, the counter
accumulates on source instances. For external handover, the
counter accumulates on target instances because the source
instance is not under this BSC.
Measurement The counter counts when BSC receives the ASS_COM/HO_COM
Point message. The measurement point is C4 as shown in Figure 105
and Figure 106 and D4 as shown in Figure 107 and Figure 108.
Unit Times

C900060169
Definition Number of data TCH/F allocation failure due to channel
activation failure for handover
Description This counter counts the number of failing to allocate TCH/F
channel due to channel activation failure during data channel
handover.
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, if the connection
succeeds, BSC sends the channel activation message CHL_ACT
to BTS to activate this TCH/F. If the channel activation fails due
to receiving channel activation failure message, incorrect
channel activation response message, T9103 being timeout,
channel instance being released, or channel being forcibly
released, this counter accumulates.
Measurement BSC activates TCH/F as data channel for handover, but receives
Point channel activation failure message, incorrect channel activation

218 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

response message, T9103 being timeout, channel instance being


released, or channel being forcibly released. The measurement
point is C3 as shown in Figure 112 and D3 as shown in Figure
113.
Unit Times

C900060170
Definition Number of TCH/F allocation failure due to BTS connection failure
for handover
Description This counter counts the number of failing to allocate TCH/F
channel due to BTS connection failure during data channel
handover.
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F channel for handover, but receives connection
Point failure message, incorrect connection response message, or
timer timeout during CMM connection process. The
measurement point is C2 as shown in Figure 140 and D2 as
shown in Figure 141.
Unit Times

C900060171
Definition Number of TCH/F allocation failure due to BIU connection failure
for handover
Description This counter counts the number of failing to allocate TCH/F
channel due to BIU connection failure during data channel
handover.
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during BIU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 219


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060172
Definition Number of TCH/F allocation failure due to TCU connection failure
for handover
Description This counter counts the number of failing to allocate TCH/F
channel due to TCU connection failure during data channel
handover.
After BSC responds to the channel request message to allocate
and occupy TCH/F channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/F for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during TCU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060173
Definition Number of data TCH/F handover success
Description This counter counts the number of successful TCH/F channel
handover during data channel handover.
When BSC detects the successful handover message sent by MS
on newly-allocated TCH/F channel, this counter accumulates.
The ASS_COM message indicates successful intra-cell handover,
and the HO_COM message indicates successful inter-cell
handover and external handover.
For intra-cell handover and inter-cell handover, the counter
accumulates on source instances. For external handover, the
counter accumulates on target instances because the source
instance is not under this BSC.
Measurement The counter counts when BSC receives the ASS_COM/HO_COM
Point message. The measurement point is C4 as shown in Figure 105
and Figure 106 and D4 as shown in Figure 107 and Figure 108.
Unit Times

C900060174
Definition Number of signaling TCH/H allocation failure for assignment
Description This counter counts the number of TCH/H channel allocation
failures during signaling channel assignment.

220 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

After BSC responds to the channel request message to allocate


and occupy TCH/H channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/H channel.
If the channel activation fails due to receiving channel activation
failure message, incorrect channel activation response message,
T9103 timeout, channel instance being released or channel
being released forcibly, this counter accumulates.
Measurement BSC activates TCH/H channel due to assignment and uses it as
Point signaling channel, but receives channel activation failure
message, incorrect channel activation response message, T9103
being timeout, channel instance being released, or channel being
forcibly released. The measurement point is A2, as shown in
Figure 111.
Unit Times

C900060175
Definition Number of TCH/H allocation failure due to channel activation
failure for assignment (speech version1)
Description This counter counts the number of TCH/H channel allocation
failure due to channel activation failure when assigning voice
channel (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/H. If the channel activation
fails due to receiving channel activation failure message,
incorrect channel activation response message, T9103 timeout,
channel instance being released or channel being released
forcibly, this counter accumulates.
Measurement BSC activates TCH/H as voice channel (using speech version 1)
Point for assignment, but the problem such as receiving channel
activation failure message, incorrect channel activation response
message, T9103 timeout, channel instance being released, or
channel being forcibly released occurs. The measurement point
is B3, as shown in Figure 118.
Unit Times

C900060176
Definition Number of TCH/H allocation failure due to BTS connection failure
for assignment (speech version1)
Description This counter counts the number of failing to allocate TCH/H
channel due to BTS connection failure when assigning voice
channel (using speech version 1).

Confidential and Proprietary Information of ZTE CORPORATION 221


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

After BSC responds to the channel request message to allocate


and occupy TCH/H channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during CMM
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060177
Definition Number of TCH/H allocation failure due to BIU connection failure
for assignment (speech version1)
Description This counter counts the number of failing to allocate TCH/H
channel due to BIU connection failure when assigning voice
channel (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during BIU
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060178
Definition Number of TCH/H allocation failure due to TCU connection failure
for assignment (speech version1)
Description This counter counts the number of failing to allocate TCH/H
channel due to TCU connection failure when assigning voice
channel (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.

222 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Measurement BSC uses TCH/H for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during TCU
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060179
Definition Number of TCH/H allocation failure due to channel activation
failure for handover (speech version1)
Description This counter counts the number of failing to allocate TCH/H
channel due to channel activation failure during voice channel
handover (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, if the connection
succeeds, BSC sends the channel activation message CHL_ACT
to BTS to activate this TCH/H. If channel activation fails due to
receiving channel activation failure message, incorrect channel
activation response message, T9103 being timeout, channel
instance being released or channel being forcibly released, this
counter accumulates.
Measurement BSC activates TCH/H channel as voice channel due to handover,
Point but receives channel activation failure message, incorrect
channel activation response message, T9103 being timeout,
channel instance being released, or channel being forcibly
released. The measurement point is C3 as shown in Figure 112
and D3 as shown in Figure 113.
Unit Times

C900060180
Definition Number of TCH/H allocation failure due to BTS connection failure
for handover (speech version1)
Description This counter counts the number of failing to allocate TCH/H
channel due to BTS connection failure during voice channel
handover (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H channel for handover, but receives connection
Point failure message, incorrect connection response message, or
timer timeout during CMM connection process. The

Confidential and Proprietary Information of ZTE CORPORATION 223


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

measurement point is C2 as shown in Figure 140 and D2 as


shown in Figure 141.
Unit Times

C900060181
Definition Number of TCH/H allocation failure due to BIU connection failure
for handover (speech version1)
Description This counter counts the number of failing to allocate TCH/H
channel due to BIU connection failure during voice channel
handover (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during BIU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060182
Definition Number of TCH/H allocation failure due to TCU connection failure
for handover (speech version1)
Description This counter counts the number of failing to allocate TCH/H
channel due to TCU connection failure during voice channel
handover (using speech version 1).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during TCU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

224 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

C900060183
Definition Number of TCH/H allocation failure due to channel activation
failure for assignment (speech version2)
Description This counter counts the number of TCH/H channel allocation
failure due to channel activation failure when assigning voice
channel (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/H. If the channel activation
fails due to receiving channel activation failure message,
incorrect channel activation response message, T9103 timeout,
channel instance being released or channel being released
forcibly, this counter accumulates.
Measurement BSC activates TCH/H as voice channel (using speech version 2)
Point for assignment, but the problem such as receiving channel
activation failure message, incorrect channel activation response
message, T9103 timeout, channel instance being released, or
channel being forcibly released occurs. The measurement point
is B3, as shown in Figure 118.
Unit Times

C900060184
Definition Number of TCH/H allocation failure due to BTS connection failure
for assignment (speech version2)
Description This counter counts the number of failing to allocate TCH/H
channel due to BTS connection failure when assigning voice
channel (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during CMM
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 225


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060185
Definition Number of TCH/H allocation failure due to BIU connection failure
for assignment (speech version2)

Description This counter counts the number of failing to allocate TCH/H


channel due to BIU connection failure when assigning voice
channel (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during BIU
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060186
Definition Number of TCH/H allocation failure due to TCU connection failure
for assignment (speech version2)
Description This counter counts the number of failing to allocate TCH/H
channel due to TCU connection failure when assigning voice
channel (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during TCU
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060187
Definition

226 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Number of TCH/H allocation failure due to channel activation


failure for handover (speech version2)
Description This counter counts the number of failing to allocate TCH/H
channel due to channel activation failure during voice channel
handover (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, if the connection
succeeds, BSC sends the channel activation message CHL_ACT
to BTS to activate this TCH/H. If channel activation fails due to
receiving channel activation failure message, incorrect channel
activation response message, T9103 being timeout, channel
instance being released or channel being forcibly released, this
counter accumulates.
Measurement BSC activates TCH/H channel as voice channel due to handover,
Point but receives channel activation failure message, incorrect
channel activation response message, T9103 being timeout,
channel instance being released, or channel being forcibly
released. The measurement point is C3 as shown in Figure 112
and D3 as shown in Figure 113.
Unit Times

C900060188
Definition Number of TCH/H allocation failure due to BTS connection failure
for handover (speech version2)
Description This counter counts the number of failing to allocate TCH/H
channel due to BTS connection failure during voice channel
handover (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H channel for handover, but receives connection
Point failure message, incorrect connection response message, or
timer timeout during CMM connection process. The
measurement point is C2 as shown in Figure 140 and D2 as
shown in Figure 141.
Unit Times

C900060189
Definition Number of TCH/H allocation failure due to BIU connection failure
for handover (speech version2)

Confidential and Proprietary Information of ZTE CORPORATION 227


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Description This counter counts the number of failing to allocate TCH/H


channel due to BIU connection failure during voice channel
handover (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during BIU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060190
Definition Number of TCH/H allocation failure due to TCU connection failure
for handover (speech version2)
Description This counter counts the number of failing to allocate TCH/H
channel due to TCU connection failure during voice channel
handover (using speech version 2).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during TCU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060191
Definition Number of TCH/H allocation failure due to channel activation
failure for assignment (speech version3)
Description This counter counts the number of TCH/H channel allocation
failure due to channel activation failure when assigning voice
channel (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/H. If the channel activation
fails due to receiving channel activation failure message,

228 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

incorrect channel activation response message, T9103 timeout,


channel instance being released or channel being released
forcibly, this counter accumulates.
Measurement BSC activates TCH/H as voice channel (using speech version 3)
Point for assignment, but the problem such as receiving channel
activation failure message, incorrect channel activation response
message, T9103 timeout, channel instance being released, or
channel being forcibly released occurs. The measurement point
is B3, as shown in Figure 118.
Unit Times

C900060192
Definition Number of TCH/H allocation failure due to BTS connection failure
for assignment (speech version3)

Description This counter counts the number of failing to allocate TCH/H


channel due to BTS connection failure when assigning voice
channel (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during CMM
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060193
Definition Number of TCH/H allocation failure due to BIU connection failure
for assignment (speech version3)
Description This counter counts the number of failing to allocate TCH/H
channel due to BIU connection failure when assigning voice
channel (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message, or timer timeout, this counter
accumulates.

Confidential and Proprietary Information of ZTE CORPORATION 229


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Measurement BSC uses TCH/H for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during BIU
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060194
Definition Number of TCH/H allocation failure due to TCU connection failure
for assignment (speech version3)
Description This counter counts the number of failing to allocate TCH/H
channel due to TCU connection failure when assigning voice
channel (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message, or timer timeout occurs during TCU
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060195
Definition Number of TCH/H allocation failure due to channel activation
failure for handover (speech version3)
Description This counter counts the number of failing to allocate TCH/H
channel due to channel activation failure during voice channel
handover (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, if the connection
succeeds, BSC sends the channel activation message CHL_ACT
to BTS to activate this TCH/H. If channel activation fails due to
receiving channel activation failure message, incorrect channel
activation response message, T9103 being timeout, channel
instance being released or channel being forcibly released, this
counter accumulates.
Measurement BSC activates TCH/H channel as voice channel due to handover,
Point but receives channel activation failure message, incorrect
channel activation response message, T9103 being timeout,
channel instance being released, or channel being forcibly

230 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

released. The measurement point is C3 as shown in Figure 112


and D3 as shown in Figure 113.
Unit Times

C900060196
Definition Number of TCH/H allocation failure due to BTS connection failure
for handover (speech version3)
Description This counter counts the number of failing to allocate TCH/H
channel due to BTS connection failure during voice channel
handover (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H channel for handover, but receives connection
Point failure message, incorrect connection response message, or
timer timeout during CMM connection process. The
measurement point is C2 as shown in Figure 140 and D2 as
shown in Figure 141.
Unit Times

C900060197
Definition Number of TCH/H allocation failure due to BIU connection failure
for handover (speech version3)
Description This counter counts the number of failing to allocate TCH/H
channel due to BIU connection failure during voice channel
handover (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during BIU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 231


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060198
Definition Number of TCH/H allocation failure due to TCU connection failure
for handover (speech version3)
Description This counter counts the number of failing to allocate TCH/H
channel due to TCU connection failure during voice channel
handover (using speech version 3).
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during TCU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060199
Definition Number of Voice TCH/H assignment success
Description This counter counts the number of successful assignments of
TCH/H as voice channel.
After BSC responds the channel request message to allocate and
occupy TCH/H channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/H. For assignment from A-
interface, after BSC receives the assignment success message,
the counter accumulates.
Measurement For assignment from A-interface, the counter accumulates when
Point BSC receives the assignment success message. The
measurement point is B5, as shown in Figure 115 and Figure
116.
Unit Times

C900060200
Definition Number of Voice TCH/H assignment failure
Description This counter counts the number of failing to assign TCH/H
channel as voice channel.
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/H. If BSC does not receive

232 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

the MS access notification within a certain time, this assignment


fails.
Measurement This counter counts when BSC receives assignment failure
Point message, abnormal message, channel instance being released,
channel instance being released forcibly, or timer timeout
message. The measurement point is B5, as shown in Figure 119.
Unit Times

C900060201
Definition Number of Voice TCH/H handover success
Description This counter counts the number of successful TCH/H channel
handover during voice channel handover.
When BSC detects the successful handover message sent by MS
on newly-allocated TCH/F channel, this counter accumulates.
The ASS_COM message indicates successful intra-cell handover,
and the HO_COM message indicates successful inter-cell
handover and external handover.
For intra-cell handover and inter-cell handover, the counter
accumulates on source instances. For external handover, the
counter accumulates on target instances because the source
instance is not under this BSC.
Measurement The counter counts when BSC receives the ASS_COM/HO_COM
Point message. The measurement point is C4 as shown in Figure 105
and Figure 106 and D4 as shown in Figure 107 and Figure 108.
Unit Times

C900060202
Definition Number of data TCH/H allocation failure due to channel
activation failure for assignment
Description This counter counts the number of TCH/H channel allocation
failure due to channel activation failure during data channel
assignment.
After BSC responds the channel request message to allocate and
occupy TCH/H channel successfully, if connection succeeds, BSC
sends the CHL_ACT message to BTS to activate this TCH/H. If
channel activation fails due to receiving channel activation
failure message, incorrect channel activation response message,
T9103 being timeout, channel instance being released or
channel being forcibly released, this counter accumulates.
Measurement BSC activates TCH/H channel due to assignment and uses the
Point channel as data channel, but receives channel activation failure
message, incorrect channel activation response message, T9103
being timeout, channel instance being released, or channel being

Confidential and Proprietary Information of ZTE CORPORATION 233


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

forcibly released. The measurement point is B3, as shown in


Figure 118.
Unit Times

C900060203
Definition Number of data TCH/H allocation failure due to BTS connection
failure for assignment
Description This counter counts the number of failing to allocate TCH/H
channel due to BTS connection failure when assigning data
channel.
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for assignment, but the problem such as
Point receiving connection failure message, incorrect connection
response message or timer timeout occurs during CMM
connection process. The measurement point is B2, as shown in
Figure 138.
Unit Times

C900060204
Definition Number of data TCH/H allocation failure due to BIU connection
failure for assignment

Description This counter counts the number of failing to allocate TCH/H


channel due to BIU connection failure when assigning data
channel.
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for assignment, but receives connection failure
Point message, incorrect connection response message or timer
timeout during BIU connection process. The measurement point
is B2, as shown in Figure 138.
Unit Times

234 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

C900060205
Definition Number of data TCH/H allocation failure due to TCU connection
failure for assignment
Description This counter counts the number of failing to allocate TCH/H
channel due to TCU connection failure when assigning data
channel.
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for assignment, but receiving connection failure
Point message, incorrect connection response message or timer
timeout during TCU connection process. The measurement point
is B2, as shown in Figure 138.
Unit Times

C900060206
Definition Number of data TCH/H allocation failure due to channel
activation failure for handover
Description This counter counts the number of failing to allocate TCH/H
channel due to channel activation failure during data channel
handover.
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, if the connection
succeeds, BSC sends the channel activation message CHL_ACT
to BTS to activate this TCH/H. If the channel activation fails due
to receiving channel activation failure message, incorrect
channel activation response message, T9103 being timeout,
channel instance being released, or channel being forcibly
released, this counter accumulates.
Measurement BSC activates TCH/H as data channel for handover, but receives
Point channel activation failure message, incorrect channel activation
response message, T9103 being timeout, channel instance being
released, or channel being forcibly released. The measurement
point is C3 as shown in Figure 112 and D3 as shown in Figure
113.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 235


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060207
Definition Number of data TCH/H allocation failure due to BTS connection
failure for handover
Description This counter counts the number of failing to allocate TCH/H
channel due to BTS connection failure during data channel
handover.
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CMM
connection request to BTS. If BTS connection fails due to
receiving CMM connection failure message, incorrect CMM
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H channel for handover, but receives connection
Point failure message, incorrect connection response message, or
timer timeout during CMM connection process. The
measurement point is C2 as shown in Figure 140 and D2 as
shown in Figure 141.
Unit Times

C900060208
Definition Number of data TCH/H allocation failure due to BIU connection
failure for handover
Description This counter counts the number of failing to allocate TCH/H
channel due to BIU connection failure during data channel
handover.
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the BIU
connection request to BIPB. If BIU connection fails due to
receiving BIU connection failure message, incorrect BIU
connection response message or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during BIU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060209
Definition Number of data TCH/H allocation failure due to TCU connection
failure for handover
Description

236 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

This counter counts the number of failing to allocate TCH/H


channel due to TCU connection failure during data channel
handover.
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the TCU
connection request to DRTB. If TCU connection fails due to
receiving TCU connection failure message, incorrect TCU
connection response message, or timer timeout, this counter
accumulates.
Measurement BSC uses TCH/H for handover, but receives connection failure
Point message, incorrect connection response message, or timer
timeout during TCU connection process. The measurement point
is C2 as shown in Figure 140 and D2 as shown in Figure 141.
Unit Times

C900060210
Definition Number of data TCH/H assignment success
Description This counter counts the number of successful assignments of
TCH/H as data channel.
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/H. For assignment from A-
interface, after BSC receives the assignment success message,
the counter accumulates.
Measurement For assignment from A-interface, the counter accumulates when
Point BSC receives the assignment success message. The
measurement point is B5, as shown in Figure 115 and Figure
116.
Unit Times

C900060211
Definition Number of data TCH/H assignment failure
Description This counter counts the number of failing to assign TCH/H
channel as data channel.
After BSC responds to the channel request message to allocate
and occupy TCH/H channel successfully, BSC sends the CHL_ACT
message to BTS to activate this TCH/H. If BSC does not receive
the MS access notification within a certain time, this assignment
fails.
Measurement This counter counts when BSC receives assignment failure
Point message, abnormal message, channel instance being released,
channel instance being released forcibly, or timer timeout
message. The measurement point is B5, as shown in Figure 119.

Confidential and Proprietary Information of ZTE CORPORATION 237


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Unit Times

C900060212
Definition Number of data TCH/H handover success
Description This counter counts the number of successful TCH/H channel
handover during data channel handover.
When BSC detects the successful handover message sent by MS
on newly-allocated TCH/H channel, this counter accumulates.
The ASS_COM message indicates successful intra-cell handover,
and the HO_COM message indicates successful inter-cell
handover and external handover.
For intra-cell handover and inter-cell handover, the counter
accumulates on source instances. For external handover, the
counter accumulates on target instances because the source
instance is not under this BSC.
Measurement The counter counts when BSC receives the ASS_COM/HO_COM
Point message. The measurement point is C4 as shown in Figure 105
and Figure 106 and D4 as shown in Figure 107 and Figure 108.
Unit Times

C900060213
Definition Number of BSC-controlled incoming handover due to forced
release
Description During BSC-controlled inter-cell incoming handover process, the
counter counts the number of forced release executions due to
no available radio resource in the target cell.
Usage This counter is used to find out the frequency of forced release
execution during BSC-controlled inter-cell incoming handover
process. It reflects the status of the handover flow.
Measurement The target cell within BSC receives the radio channel request
Point message. If the request is due to BSC-controlled inter-cell
incoming handover and the target cell has no available radio
channels, forced release is performed. When the target cell
receives the message of resource available returned by the
forced release instance, the counter increments. The
measurement point is A, as shown in Figure 142.

238 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

FIGURE 142 – FORCED RELEASE EXECUTION

Unit Times

C900060214
Definition Number of BSC-controlled incoming handover due to queues
Description During BSC-controlled inter-cell incoming handover process, the
counter counts the number of queuing executions due to no
available radio resource in the target cell.
Usage This counter is used to find out the frequency of queuing
execution during BSC-controlled inter-cell incoming handover
process. It reflects the status of the handover flow.
Measurement The target cell within BSC receives the radio channel request
Point message. If the request is due to BSC-controlled inter-cell
incoming handover and the target cell has no available radio
channels, the target instance is added to the waiting queue.
When the target cell receives the message of resource available,
the counter increments. The measurement point is A, as shown
in Figure 143.

FIGURE 143 – QUEUING EXECUTION

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 239


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060215
Definition Number of BSC-controlled incoming handover due to forced
handover
Description During BSC-controlled inter-cell incoming handover process, the
counter counts the number of forced handover executions due to
no available radio resource in the target cell.
Usage This counter is used to find out the frequency of forced handover
execution during BSC-controlled inter-cell incoming handover
process. It reflects the status of the handover flow.
Measurement The target cell within BSC receives the radio channel request
Point message. If the request is due to BSC-controlled inter-cell
incoming handover and the target cell has no available radio
channels, the forced handover message is sent to the forced
handover instance and the target instance is added to the
waiting queue. When the target cell receives the message of
resource available, the counter increments. The measurement
point is A, as shown in Figure 144.

FIGURE 144 – FORCED HANDOVER EXECUTION

Unit Times

C900060216
Definition Number of MSC-controlled incoming handover due to forced
handover
Description During MSC-controlled inter-BSC incoming handover process,
the counter counts the number of forced handover executions
due to no available radio resource in the target cell.
Usage This counter is used to find out the frequency of forced handover
executions during MSC-controlled inter-BSC incoming handover
process. It reflects the status of the handover flow.
Measurement The target cell receives the radio channel request message. If
Point the request is due to MSC-controlled inter-BSC incoming
handover and the target cell has no available radio channels, the
forced handover message is sent to the forced handover

240 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

instance and the target instance is added to the waiting queue.


When the target cell receives the message of resource available,
the counter increments. The measurement point is A, as shown
in Figure 144.
Unit Times

C900060217
Definition Number of unavailable defined TCH/H
Description iBSC supports the function of full dynamic radio channel. This
counter counts the number of unavailable TCH/H channel
configured by OMCR in the current cell.
Usage This counter is used to find out the number of unavailable TCH/H
channel in the current cell to facilitate eliminating the fault.
Measurement Query the database when periodic measurement data is reported
Point to get the value of the counter. The measurement point is A, as
shown in Figure 137.
Unit Times

C900060218
Definition Number of unavailable defined TCH/F
Description iBSC supports the function of full dynamic wireless channel. This
counter counts the number of unavailable TCH/F channel
configured by OMCR in the current cell.
Usage This counter is used to find out the number of unavailable TCH/F
channel in the current cell to facilitate eliminating the fault.
Measurement Query the database when periodic measurement data is reported
Point to get the value of the counter. The measurement point is A, as
shown in Figure 137.
Unit Times

C900060219
Definition Number of signaling TCH/F drops due to handover failure
Description This counter counts the number of call drops due to handover
failure on TCH/F signaling channel. Call drop occurs after MS
requests for TCH/F signaling channel successfully. If the problem
is due to handover failure, the counter increments.
Presently, reasons for handover failure include T3107 timeout,
T3103 timeout and external handover timer timeout under the
status of ASSIGNING.

Confidential and Proprietary Information of ZTE CORPORATION 241


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Usage This counter is used to find out the frequency of call drop due to
handover failure on TCH/F signaling channel.
Measurement TCH/F signaling channel is activated after BSC initiates the
Point handover flow. After that:
„ If RANCS is in the status of RADIO_APPLY and sends the
intra-cell handover command, then T3107 is started. If
RANCS is in the status of ASSIGN and T3107 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 122.
„ If RANCS is in the status of RADIO_APPLY and sends the
inter-cell handover command, then T3103 is started. If
RANCS is in the status of ASSIGN and T3103 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 123.
„ If RANCS is in the status of RADIO_APPLY and sends the
external handover command, then the external handover
timer is started. If RANCS is in the status of ASSIGN and the
external handover timer is timeout, then the counter
increments. The measurement point is A1, as shown in
Figure 145.

FIGURE 145 – CALL DROP DUE TO INTER-BSC HANDOVER FAILURE

MS BTS1 BSC1 MSC BSC2 BTS2


Meas Rep
Meas Rep
Ho Req
CR(Ho Req)

CC A2
Chan Act
Chan Act Ack
Ho Req Ack
Ho cmd
Ho Cmd HO Detec
HO Detec
A1 Est Ind
HO Complete

Clear Cmd

Unit Times

C900060220
Definition Number of voice TCH/F drops due to handover failure
Description This counter counts the number of call drops on TCH/F voice
channel due to handover failure. Call drop occurs after MS
requests for TCH/F voice channel successfully. The counter
increments if call drop is due to handover failure.
Presently, reasons for handover failure include T3107 timeout,
T3103 timeout and external handover timer timeout under the
status of ASSIGNING.
Usage

242 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

This counter is used to find out the frequency of call drop on


TCH/F voice channel due to handover failure.
Measurement TCH/F voice channel is activated after BSC initiates the handover
Point flow. After that:
„ If RANCS is in the status of RADIO_APPLY and sends the
intra-cell handover command, then T3107 is started. If
RANCS is in the status of ASSIGN and T3107 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 122.
„ If RANCS is in the status of RADIO_APPLY and sends the
inter-cell handover command, then T3103 is started. If
RANCS is in the status of ASSIGN and T3103 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 123.
„ If RANCS is in the status of RADIO_APPLY and sends the
external handover command, then the external handover
timer is started. If RANCS is in the status of ASSIGN and the
external handover timer is timeout, then the counter
increments. The measurement point is A1, as shown in
Figure 145.
Unit Times

C900060221
Definition Number of data TCH/F drops due to handover failure
Description This counter counts the number of call drops on TCH/F data
channel due to handover failure. Call drop occurs after MS
requests for TCH/F data channel successfully. The counter
increments if call drop is due to handover failure.
Presently, reasons for handover failure include T3107 timeout,
T3103 timeout and external handover timer timeout under the
status of ASSIGNING.
Usage This counter is used to find out the frequency of call drop on
TCH/F data channel due to handover failure.
Measurement TCH/F data channel is activated after BSC initiates the handover
Point flow. After that:
„ If RANCS is in the status of RADIO_APPLY and sends the
intra-cell handover command, then T3107 is started. If
RANCS is in the status of ASSIGN and T3107 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 122.
„ If RANCS is in the status of RADIO_APPLY and sends the
inter-cell handover command, then T3103 is started. If
RANCS is in the status of ASSIGN and T3103 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 123.

Confidential and Proprietary Information of ZTE CORPORATION 243


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

„ If RANCS is in the status of RADIO_APPLY and sends the


external handover command, then the external handover
timer is started. If RANCS is in the status of ASSIGN and the
external handover timer is timeout, then the counter
increments. The measurement point is A1, as shown in
Figure 145.
Unit Times

C900060222
Definition Number of signaling TCH/H drops due to handover failure
Description This counter counts the number of call drops due to handover
failure on TCH/H signaling channel. Call drop occurs after MS
requests for TCH/H signaling channel successfully. If the
problem is due to handover failure, the counter increments.
Presently, reasons for handover failure include T3107 timeout,
T3103 timeout and external handover timer timeout under the
status of ASSIGNING.
Usage This counter is used to find out the frequency of call drop due to
handover failure on TCH/H signaling channel.
Measurement TCH/H signaling channel is activated after BSC initiates the
Point handover flow. After that:
„ If RANCS is in the status of RADIO_APPLY and sends the
intra-cell handover command, then T3107 is started. If
RANCS is in the status of ASSIGN and T3107 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 122.
„ If RANCS is in the status of RADIO_APPLY and sends the
inter-cell handover command, then T3103 is started. If
RANCS is in the status of ASSIGN and T3103 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 123.
„ If RANCS is in the status of RADIO_APPLY and sends the
external handover command, then the external handover
timer is started. If RANCS is in the status of ASSIGN and the
external handover timer is timeout, then the counter
increments. The measurement point is A1, as shown in
Figure 145.
Unit Times

C900060223
Definition Number of data TCH/H drops due to handover failure
Description This counter counts the number of call drops due to handover
failure on TCH/H data channel. Call drop occurs after MS

244 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

requests for TCH/H data channel successfully. If the problem is


due to handover failure, the counter increments.
Presently, reasons for handover failure include T3107 timeout,
T3103 timeout and external handover timer timeout under the
status of ASSIGNING.
Usage This counter is used to find out the frequency of call drop due to
handover failure on TCH/H data channel.
Measurement TCH/H data channel is activated after BSC initiates the handover
Point flow. After that:
„ If RANCS is in the status of RADIO_APPLY and sends the
intra-cell handover command, then T3107 is started. If
RANCS is in the status of ASSIGN and T3107 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 122.
„ If RANCS is in the status of RADIO_APPLY and sends the
inter-cell handover command, then T3103 is started. If
RANCS is in the status of ASSIGN and T3103 is timeout, then
the counter increments. The measurement point is A, as
shown in Figure 123.
„ If RANCS is in the status of RADIO_APPLY and sends the
external handover command, then the external handover
timer is started. If RANCS is in the status of ASSIGN and the
external handover timer is timeout, then the counter
increments. The measurement point is A1, as shown in
Figure 145.
Unit Times

C900060224
Definition Number of TCH/H handover attempts due to UL strength
Description This counter counts the number of handover attempts due to UL
receiving strength too low on TCH/H channel.
Usage This counter is used to find out the frequency of handover due to
UL receiving strength on TCH/H channel. If the counter’s value is
too large, it indicates poor UL level on TCH/H channel.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/H channel. If handover decision succeeds and the
handover is due to UL strength, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060225
Definition Number of TCH/H handover attempts due to DL strength

Confidential and Proprietary Information of ZTE CORPORATION 245


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Description This counter counts the number of handover attempts due to DL


receiving strength too low on TCH/H channel.
Usage This counter is used to find out the frequency of handover due to
DL receiving strength on TCH/H channel. If the counter’s value is
too large, it indicates poor DL level on TCH/H channel.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/H channel. If handover decision succeeds and the
handover is due to DL strength, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060226
Definition Number of TCH/H handover attempts due to UL quality
Description This counter counts the number of handover attempts due to UL
quality too poor on TCH/H channel.
Usage This counter is used to find out the frequency of handover due to
UL quality on TCH/H channel. If the counter’s value is too large,
it indicates poor UL quality on TCH/H channel.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/H channel. If handover decision succeeds and the
handover is due to UL quality, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060227
Definition Number of TCH/H handover attempts due to DL quality
Description This counter counts the number of handover attempts due to DL
quality too poor on TCH/H channel.
Usage This counter is used to find out the frequency of handover due to
DL quality on TCH/H channel. If the counter’s value is too large,
it indicates poor DL quality on TCH/H channel.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/H channel. If handover decision succeeds and the
handover is due to DL quality, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060228
Definition Number of TCH/H handover attempts due to UL interference

246 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Description This counter counts the number of handover attempts due to UL


interference too large on TCH/H channel.
Usage This counter is used to find out the frequency of handover due to
UL interference on TCH/H channel. If the counter’s value is too
large, it indicates large UL interference on TCH/H channel.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/H channel. If handover decision succeeds and the
handover is due to UL interference, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060229
Definition Number of TCH/H handover attempts due to DL interference
Description This counter counts the number of handover attempts due to DL
interference too large on TCH/H channel.
Usage This counter is used to find out the frequency of handover due to
DL interference on TCH/H channel. If the counter’s value is too
large, it indicates large DL interference on TCH/H channel.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/H channel. If handover decision succeeds and the
handover is due to DL interference, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060230
Definition Number of TCH/H handover attempts due to good C/I
Description This counter counts the number of MS handover attempts due to
too large C/I ratio on TCH/H channel. The handover only occurs
during sub-cell configuration and when C/I algorithm is adopted;
MS performs handover from external circle to internal circle.
Usage This counter is used to find out the frequency of MS handover
due to too large C/I ratio on TCH/H channel. If the counter’s
value is too large, it indicates that, after MS accesses the
external circle, MS performs handover to the internal circle many
times due to good C/I ratio and the internal circle absorbs the
traffic.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/H channel. If handover decision succeeds and the
handover is due to too large C/I ratio, this counter increments.
The measurement point is A, as shown in Figure 124.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 247


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060231
Definition Number of TCH/H handover attempts due to bad C/I
Description This counter counts the number of MS handover attempts due to
too low C/I ratio on TCH/H channel. The handover only occurs
during sub-cell configuration and when C/I algorithm is adopted;
MS performs handover from internal circle to external circle.
Usage This counter is used to find out the frequency of MS handover
due to too low C/I ratio on TCH/H channel. If the counter’s value
is too large, it indicates that, when MS calls within the internal
circle, MS performs handover to the external circle many times
due to poor C/I ratio. Interference within the internal circle is big,
and C/I ratio of the internal circle can be improved by adjusting
the carrier power.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/H channel. If handover decision succeeds and the
handover is due to too low C/I ratio, this counter increments.
The measurement point is A, as shown in Figure 124.
Unit Times

C900060232
Definition Number of TCH/H handover attempts due to PBGT
Description This counter counts the number of MS handover attempts due to
PBGT value on TCH/H channel. If PBGT value is larger than zero,
it indicates the adjacent cell has better radio environment than
the current cell. If the number of times that PBGT value is larger
than zero reaches the threshold, PBGT handover occurs.
Usage This counter is used to find out the frequency of MS handover
due to PBGT value on TCH/H channel. If the counter’s value is
too large, it indicates that signal on TCH/H channel within the
current cell is poorer than that in the adjacent cell.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/H channel. If handover decision succeeds and the
handover is due to PBGT value, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060233
Definition Number of TCH/H handover attempts due to large TA
Description This counter counts the number of MS handover attempts due to
too large TA on TCH/H channel. Increasing TA indicates that MS

248 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

is moving away from the current cell. When the distance reaches
a certain value, handover will occur due to too large TA.
Usage This counter is used to find out the frequency of MS handover
due to too large TA on TCH/F channel. The counter’s value
reflects the mobility of subscribers in the current cell to a certain
extent.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/H channel. If handover decision succeeds and the
handover is due to too large TA, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060234
Definition Number of TCH/H handover attempts due to other reasons
Description This counter counts the number of handover attempts due to
any other reason beyond the handover reasons mentioned
previously.
Usage This counter is used to find out the frequency of handover due to
any other reason.
Measurement BSC performs handover decision after receiving measurement
Point report on TCH/H channel. If handover decision succeeds and the
handover is due to any other reason beyond the handover
reasons mentioned previously, this counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C900060235
Definition Number of signaling TCH/H assignment success
Description This counter counts the number of successfully assigning TCH/H
channel as signaling channel.
After BSC responds the channel request and successfully
allocates and occupies the channel, BSC sends channel
activation message CHL_ACT to activate the TCH/H. For
immediate assignment, after the channel activation succeeds,
BTS receives the MS access message and sends EST_IND to BSC.
The counter increments when BSC receives the message
correctly.
Measurement For immediate assignment, the counter increments when BSC
Point receives the EST_IND message correctly. The measurement
point is A3, as shown in Figure 103.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 249


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060236
Definition Number of MOC access success
Description This counter counts the number of Mobile Originated Call (MOC)
MS successfully accesses the channel allocated in the immediate
assignment message. When MS receives IMM_ASS issued by
BSC, MS accesses the corresponding channel successfully. The
counter increments when BSC receives the EST_IND message
from MS.
Usage This counter is used to find out the frequency of successful MS
access due to MOC.
Measurement The counter increments when BSC receives the EST_IND
Point message. The measurement point is A4, as shown in Figure 99.
Unit Times

C900060237
Definition Number of dual band outgoing handover
Description This counter counts the number of MSC-controlled inter-BSC
outgoing handovers that are initiated by MS in the source cell
(the source cell and the target cell are of different frequency
bands).
Usage This counter is used to find out the frequency of MSC-controlled
inter-BSC outgoing handover that is initiated by MS. The source
cell and the target cell are of different frequency bands.
Measurement BSC performs handover decision after receiving the
Point measurement report sent by MS. If the decision indicates that
inter-cell handover is necessary and if the current cell to which
the handover is attempted is a cell under different BSC, then
BSC sends the handover request A_HO_RQD to MSC to trigger
inter-BSC handover. If BSC receives the handover command
returned from MSC and if the source cell and the target cell are
of different frequency bands, then this counter increments. The
measurement point is A, as shown in Figure 127.
Unit Times

C900060238
Definition Number of dual band outgoing handover success
Description This counter counts the number of successful MSC-controlled
inter-BSC outgoing handovers that are initiated by MS in the
source cell (the source cell and the target cell are of different
frequency bands).

250 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Usage This counter is used to find out the frequency of successful MSC-
controlled inter-BSC outgoing handover that is initiated by MS.
The source cell and the target cell are of different frequency
bands.
Measurement BSC performs handover decision after receiving the
Point measurement report sent by MS. If the decision indicates that
inter-cell handover is necessary and if the current cell to which
the handover is attempted is a cell under different BSC, then
BSC sends the handover request A_HO_RQD to MSC to trigger
inter-BSC handover. If MS accesses the target cell successfully,
the source cell receives the release command issued by MSC, if
the source cell and the target cell are of different frequency
bands, then this counter increments. The measurement point is
A, as shown in Figure 128.
Unit Times

C900060239
Definition Number of dual band incoming handover
Description This counter counts the number of inter-BSC incoming
handovers to the current cell that are initiated by MSC (the
source cell and the target cell are of different frequency bands).
Usage This counter is used to find out the frequency of inter-BSC
incoming handover that is initiated by MSC. The source cell and
the target cell are of different frequency bands.
Measurement After the target cell receives the handover request issued by
Point MSC, if the target cell occupies and activates the channel
successfully and if the source cell and the target cell are of
different frequency bands, then this counter increments. The
measurement point is A, as shown in Figure 131.
Unit Times

C900060240
Definition Number of dual band incoming handover success
Description This counter counts the number of successful MSC-controlled
inter-BSC incoming handovers that are initiated by MS (the
source cell and the target cell are of different frequency bands).
Usage This counter is used to find out the frequency of MSC-controlled
inter-cell handover that is initiated by MS. The source cell and
the target cell are of different frequency bands.
Measurement After the target cell receives the handover completion message,
Point if the request is due to MSC-controlled inter-BSC incoming
handover and if the source cell and the target cell are of

Confidential and Proprietary Information of ZTE CORPORATION 251


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

different frequency bands, then this counter increments. The


measurement point is A, as shown in Figure 134.
Unit Times

C900060241
Definition Number of SDCCH assignment attempts
Description After BSC responds to the channel request to allocate and
activate SDCCH channel successfully, BSC sends the IMM_ASS
message to notify MS to use this channel. After MS receives this
message, it sends SABM frame to BTS on SDCCH. BTS then
sends the EST_IND message to BSC after receiving SABM frame.
„ If BSC receives the correct EST_IND message within
specified time, it indicates that the SDCCH channel
assignment succeeds, C900060241 and C900060242
accumulate simultaneously.
„ If BSC receives the incorrect EST_IND message or T3101 is
timeout, it indicates that the SDCCH channel assignment fails,
C900060241 and C900060243 accumulate simultaneously.
Usage This counter counts the number of SDCCH channel assignment
attempts when BSC sends the IMM_ASS message to notify MS to
use the allocated SDCCH channel. The counter’s value includes
the number of assignment success (C900060242) and the
number of assignment failure (C900060243).
Measurement This counter counts when BSC receives the EST_IND message or
Point the assignment completion message, or when T3101 is timeout
(C900060242 + C900060243). The measurement point is A3, as
shown in Figure 100.
Unit Times

C900060242
Definition Number of SDCCH assignments success

Description After BSC responds to the channel request to allocate and


activate SDCCH channel successfully, BSC sends the IMM_ASS
message to notify MS to use this channel. After MS receives this
message, it sends SABM frame to BTS on SDCCH. BTS then
sends the EST_IND message to BSC after receiving SABM frame.
If BSC receives the correct EST_IND message within specified
time, it indicates that the SDCCH channel assignment succeeds,
then this counter increments.
Usage This counter counts the number of MS successfully accessing
SDCCH channel when BSC sends the IMM_ASS message.

252 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - CS Basic Measurement

Measurement This counter counts when BSC receives the correct EST_IND
Point message or the assignment completion message. The
measurement point is A3, as shown in Figure 100.
Unit Times

C900060243
Definition Number of SDCCH assignment failure
Description After BSC responds to the channel request to allocate and
activate SDCCH channel successfully, BSC sends the IMM_ASS
message to notify MS to use this channel. After MS receives this
message, it sends SABM frame to BTS on SDCCH. BTS then
sends the EST_IND message to BSC after receiving SABM frame.
If BSC receives the incorrect EST_IND message or T3101 is
timeout, it indicates that the SDCCH channel assignment fails,
then this counter increments.
Usage This counter counts the number of MS failing to access SDCCH
channel when BSC sends the IMM_ASS message.
Measurement This counter counts when BSC receives the incorrect EST_IND
Point message or when T3101 is timeout. The measurement point is
A3, as shown in Figure 100.
Unit Times

C900060244
Definition Number of voice TCH/F drops due to radio link failure
Description This counter counts the number of voice TCH/F drops due to
radio link failure. After MS applies for TCH/F voice channel, call
drops. If this problem is caused by radio link failure, then this
counter increments.
Usage This counter is used to learn the call drop frequency caused by
raio link failure on TCH/F voice.
Measurement On TCH/F voice channel, when BSC receives Connection Failure
Point Indication message at Abis interface, this counter counts. The
measurement point is A, as shown in Figure 146.

Confidential and Proprietary Information of ZTE CORPORATION 253


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

FIGURE 146 - CALL DROPS CAUSED BY RADIO LINK FAILURE DURING


ASSIGNMENT

Unit Times

C900060245
Definition Number of voice TCH/H drops due to radio link failure
Description This counter counts the number of voice TCH/H drops due to
radio link failure. After MS applies for TCH/H voice channel, call
drops. If this problem is caused by radio link failure, then this
counter increments.
Usage This counter is used to learn the call drop frequency caused by
raio link failure on TCH/H voice.
Measurement On TCH/H voice channel, when BSC receives Connection Failure
Point Indication message at Abis interface, this counter counts. The
measurement point is A, as shown in Figure 146.
Unit Times

254 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5

Configuration
Management Infomation
Basic Measurement

This chapter contains detailed information about counters


related to configuration management information basic
measurement.

Overview
Configuration management information basic measurement
records the cell's basic configuration information of each
measurement period.
Statistic unit in this measurement is cell.

Configuration Management
Infomation Basic Measurement
Counter Index
Table 9 lists counters related to configuration management
information basic measurement.

TABLE 9 – CONFIGURATION M ANAGEMENT INFORM ATION BASIC


MEASUREMENT COUNTERS

Counter ID What It Counts


C900090001 Cell frequency band
C900090002 Number of TRX
C900090003 Number of TCH

Confidential and Proprietary Information of ZTE CORPORATION 255


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Counter ID What It Counts


C900090004 Number of SDCCH
C900090005 Radio capacity (call loss 1)
C900090006 Radio capacity (call loss 2)
C900090007 Radio capacity (based on TRX)
C900090008 Number of static PDTCH
C900090009 Number of dynamic PDTCH

C900090001
Definition Cell frequency band
Description This counter records frequency bands set in the cell. Refer to
configuration information for frequency band values.
Usage This counter is used to find out frequency bands set at specific
time segment in the cell.
Unit None

C900090002
Definition Number of TRX
Description This counter records the number of TRXs in the cell.
Usage This counter is used to find out the number of TRXs in the cell at
specific time segment.
Unit Times

C900090003
Definition Number of TCH
Description This counter records the number of voice channels in the cell.
Usage This counter is used to find out the number of voice channels in
the cell at specific time segment.
Unit Times

C900090004
Definition Number of SDCCH

256 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Configuration Management Infomation Basic Measurement

Description This counter records the number of signaling channels in the cell.
Usage This counter is used to find out the number of signaling channels
in the cell at specific time segment.
Unit Times

C900090005
Definition Radio capacity (call loss 1)
Description This counter records the cell's maximum traffic capacity in
theory, and it gets the radio capacity (call loss 1) from the
Erlang table according to the number of voice channels.
Usage This counter is used to find out the cell's maximum traffic
capacity in theory at specific time segment.
Unit Number of Erlangs × 10000

C900090006
Definition Radio capacity (call loss 2)
Description This counter records the cell's maximum traffic capacity in
theory, and it gets the radio capacity (call loss 2) from the
Erlang table according to the number of voice channels.
Usage This counter is used to find out the cell's maximum traffic
capacity in theory at specific time segment.
Unit Number of Erlangs × 10000

C900090007
Definition Radio capacity (based on TRX)
Description This counter records the cell's maximum traffic capacity in
theory. The radio capacity is calculated according to the number
of carriers: 2.28 for a single carrier, 8.25 for dual carriers, 14.04
for three carriers, and 21.04 for four carriers.
Usage This counter is used to find out the cell's maximum traffic
capacity in theory at specific time segment.
Unit Number of Erlangs × 10000

C900090008
Definition Number of static PDTCH
Description This counter records the number of static PDTCHs in the cell.

Confidential and Proprietary Information of ZTE CORPORATION 257


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Usage This counter is used to find out the number of static PDTCHs in
the cell at specific time segment.
Unit Times

C900090009
Definition Number of dynamic PDTCH
Description This counter records the number of dynamic PDTCHs in the cell.
Usage This counter is used to find out the number of dynamic PDTCHs
in the cell at specific time segment.
Unit Times

258 Confidential and Proprietary Information of ZTE CORPORATION


Appendix A

Abbreviations

Abbreviation Full Name


A
Abis Abis Interface
AIPP A-Interface Peripheral Processor
AIU A-Interface Unit
AUC Access Unit Controller
B
BCCH Broadcast Channel
BSC Base Station Controller
BTS Base Transceiver Station
BSSAP Base Station Subsystem Application Part
BSSGP Base Station Subsystem GPRS Protocol
BSSMAP Base Station Subsystem Management
Application Part
BTS Base Transceiver Station
BVC BSSGP Virtual Connection
BVCI BSSGP Virtual Connection Identifier
C
CBCH Cell Broadcast Channel
CC Call Control
CCCH Common Control Channel
CCH Control Channel
CS Circuit Switched
D
DRT Dual Rate Transcoder
DTAP Direct Transfer Application Part
E

Confidential and Proprietary Information of ZTE CORPORATION 259


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Abbreviation Full Name


EDRT Enhanced Dual Rate Transcoder
EGSM Extended GSM
F
FACCH Fast Associated Control Channel
FACCH/F Fast Associated Control Channel/Full rate
FACCH/H Fast Associated Control Channel/Half rate
FR Frame Relay
FRP Frame Relay Protocol
FU Frame Unit
G
GGSN Gateway GPRS Support Node
GIU GPRS Interface Unit
GPRS General Packet Radio Service
GSM Global System for Mobile communication
GSN GPRS Support Node
H
HSN Hopping Sequence Number
K
KPI Key Performance Indicator
L
LAPD Link Access Protocol of D-Channel
LLC Logical Link Control
LMT Local Management Terminal
LOC Location update
M
MM Mobility Management
MOC Mobile Originated Call
MS Mobile Station
MSC Mobile Switching Center
MO-SM MS Originated Short Message
MT-SM MS Terminated Short Message
MTC Mobile Terminated Call
MTP Message Transfer Part
N
NC Network Controller
NMS Network Management Signaling

260 Confidential and Proprietary Information of ZTE CORPORATION


Appendix A - Abbreviations

Abbreviation Full Name


NMS Network Management Software
NS Network Service
NSE Network Service Entity
NSEI Network Service Entity Identifier
NSVC Network Service Virtual Circuit
O
OMC Operation Maintenance Center
OMCR Operation Maintenance Center Radio
P
PACCH Packet Associated Control Channel
PAGCH Paging and Access Grant Channel
PBGT Power Budget
PCH Paging Channel
PCU Packet Control Unit
PDU Protocol Data Unit
PDCH Packet Data Channel
PDTCH Packet Data Traffic Channel
PDU Protocol Data Unit
PS Packet Switched
R
RMM Radio Management Module
RQ Receiving Quality
RR Radio Resource
S
SACCH Slow Associated Control Channel
SACCH/F Slow Associated Control Channel/Full rate
SACCH/H Slow Associated Control Channel/Half rate
SAPI Service Access Point Identifier
SCCP Signal Correction Control Part
SDCCH Slow Distributed Control Channel
SGSN Serving GPRS Support Node
SIF Service Information Field
SIO Service Information Octets
SM Short Message
SMM Service Management Module
SMS Short Messages Service

Confidential and Proprietary Information of ZTE CORPORATION 261


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Abbreviation Full Name


SS Supplementary Services
T
TA Time Advance
TCH Traffic Channel
TCH/F Traffic Channel/Full rate
TCH/H Traffic Channel/Half rate
TFO Tandem Free Operation
TIC Trunk Interface Circuit
TRX Transceiver
U
UISF User Interface Support Foundation

262 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B

Figures

Figure 1 – Measurement Point of Number of Requests for


Establishing GPRS Downlink Data TBF before T3192 Overtime 12
Figure 2 – Measurement Point of Number of Established GPRS
Downlink Data TBF Using Existing Resources ........................ 13
Figure 3 – Measurement Point of Number of Requests for
Establishing GPRS Downlink Data TBF on Uplink GPRS TBF
PACCH ............................................................................ 13
Figure 4 – Measurement Point of Number of GPRS DL TBF
Release due to N3105 Overflow .......................................... 14
Figure 5 – Measurement Point of Number of GPRS DL TBF
Release due to other Reasons ............................................ 14
Figure 6 – Measurement Point of Number of GPRS DL TBF
Forcing Release by Control Plane ........................................ 15
Figure 7 - Measurement Point of Number of GPRS DL TBF
Release due to Instance Suspension.................................... 16
Figure 8 – Measurement Point of Number of EGPRS DL TBF
Release due to N3105 Overflow .......................................... 18
Figure 9 – Measurement Point of Number of EGPRS DL TBF
Release due to other Reasons ............................................ 18
Figure 10 – Measurement Point of Number of EGPRS DL TBF
Forcing Release by Control Plane ........................................ 19
Figure 11 - Measurement Point of Number of EGPRS DL TBF
Release due to Instance Suspension.................................... 20
Figure 12 - Measurement Point of Number of GPRS UL Data TBF
Establishment Success on PACCH ....................................... 22
Figure 13 - Measurement Point of Number of GPRS UL TBF
Release due to N3101 Overflow .......................................... 22
Figure 14 - Measurement Point of Number of GPRS UL TBF
Release due to N3103 Overflow .......................................... 23
Figure 15 - Measurement Point of Number of GPRS UL TBF
Forcing Release by Control Plane ........................................ 23

Confidential and Proprietary Information of ZTE CORPORATION 263


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Figure 16 - Measurement Point of Number of GPRS UL TBF


Release due to Instance Suspension.................................... 24
Figure 17 – UL TBF Flow of 1-Step Access ............................ 25
Figure 18 - UL TBF Flow of 2-Step Access ............................ 26
Figure 19 - Measurement Point of Number of EGPRS UL TBF
Establishment Success on PACCH ....................................... 27
Figure 20 - Measurement Point of Number of EGPRS DL LLC
Frames ........................................................................... 34
Figure 21 - Measurement Point of Number of Discarded EGPRS
DL LLC Frames due to Buffer Overflow................................. 34
Figure 22 - Measurement Point of Number of Discarded EGPRS
DL LLC Frames due to Life Time Expiration........................... 35
Figure 23 - Measurement Point of Number of Discarded EGPRS
DL LLC Frames due to other Reasons .................................. 35
Figure 24 - Measurement Point of Number of DL Signaling LLC
Frames ........................................................................... 36
Figure 25 - Measurement Point of Number of Discarded EGPRS
DL Signaling LLC Frames due to Buffer Overflow ................... 36
Figure 26 - Measurement Point of Number of Discarded EGPRS
DL Signaling LLC Frames due to Life Time Expiration ............. 37
Figure 27 - Measurement Point of Number of Discarded EGPRS
DL Signaling LLC Frames due to other Reasons ..................... 38
Figure 28 - Measurement Point of Total Bytes of Effective Upper
Layer Protocol Data Sent on DL PDCH ................................. 39
Figure 29 - Measurement Point of Total Bytes of Effective Upper
Layer Protocol Data Received on UL PDCH............................ 39
Figure 30 - Measurement Point of Bytes of LLC Frame on GPRS
UL Data TBF .................................................................... 40
Figure 31 - Measurement Point of Duration of GPRS UL Data TBF
..................................................................................... 40
Figure 32 - Measurement Point of Bytes of LLC Frame on GPRS
DL Data TBF .................................................................... 41
Figure 33 - Measurement Point of Duration of GPRS DL Data TBF
..................................................................................... 41
Figure 34 - Measurement Point of Number of Effective Data
Blocks Received on GPRS UL TBF ........................................ 42
Figure 35 - Measurement Point of Number of NACK Blocks
Received on GPRS UL TBF.................................................. 43
Figure 36 - Measurement Point of Number of Effective Data
Blocks Sent on GPRS DL TBF.............................................. 43
Figure 37 - Measurement Point of Number of NACK Blocks Sent
on GPRS DL TBF............................................................... 44

264 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B - Figures

Figure 38 - Measurement Point of Bytes of LLC Frame on EGPRS


UL Data TBF .................................................................... 45
Figure 39 - Measurement Point of Duration of EGPRS UL data
TBF ................................................................................ 45
Figure 40 - Measurement Point of Bytes of LLC Frame on EGPRS
DL Data TBF .................................................................... 46
Figure 41 - Measurement Point of Duration of EGPRS DL Data
TBF ................................................................................ 46
Figure 42 - Measurement Point of Number of Effective Data
Blocks Received on EGPRS UL TBF ...................................... 47
Figure 43 - Measurement Point of Number of NACK Blocks
Received on EGPRS UL TBF ................................................ 47
Figure 44 - Measurement Point of Number of Effective Data
Blocks Sent on EGPRS DL TBF ............................................ 48
Figure 45 - Measurement Point of Number of NACK Blocks Sent
on EGPRS DL TBF ............................................................. 49
Figure 46 - Measurement Point of Number of GPRS DL LLC
Frames ........................................................................... 49
Figure 47 - Measurement Point of Number of Discarded GPRS DL
LLC Frames due to Buffer Overflow ..................................... 50
Figure 48 - Measurement Point of Number of Discarded GPRS DL
LLC Frames due to Life Time Expiration ............................... 50
Figure 49 - Measurement Point of Number of Discarded GPRS DL
LLC Frames due to other Reasons ....................................... 51
Figure 50 - Measurement Point of Number of DL Dummy Control
Blocks on PACCH .............................................................. 52
Figure 51 - Measurement Point of Number of UL Dummy Control
Blocks on PACCH .............................................................. 52
Figure 52 - Measurement Point of Number of DL RLC Blocks on
PACCH (Excluding Dummy Block) ....................................... 53
Figure 53 - Measurement Point of Number of DL RLC Pending
Blocks on PDTCH .............................................................. 53
Figure 54 - Measurement Point of Number of DL RLC NACK
Blocks on PDTCH .............................................................. 55
Figure 55 – Measurement Point of Number of DL RLC New Blocks
on PDTCH........................................................................ 56
Figure 56 - Measurement Point of Number of UL RLC Blocks
Excluding Dummy Blocks on PACCH .................................... 58
Figure 57 - Measurement Point of Number of UL RLC Pending
Blocks on PDTCH .............................................................. 58
Figure 58 - Measurement Point of Number of UL RLC NACK
Blocks on PDTCH .............................................................. 60
Figure 59 – Measurement Point of Number of UL RLC New Blocks
on PDTCH........................................................................ 62

Confidential and Proprietary Information of ZTE CORPORATION 265


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Figure 60 - Measurement Point of Allocation Failures after


Receiving DL TBF Establishment Request ............................. 64
Figure 61 - Measurement Point of Allocation Failures after
Receiving DL TBF Assignment Message ................................ 65
Figure 62 - Measurement Point of Number of GPRS DL TBF
Resource Reallocation Requests due to UL TBF Establishment . 65
Figure 63 - Measurement Point of Number of GPRS DL TBF
Resource Reallocation Failure due to UL TBF Establishment .... 66
Figure 64 - Measurement Point of Number of GPRS DL TBF
Resource Reallocation Requests due to LLC Transmission ....... 67
Figure 65 - Measurement Point of Number of GPRS DL TBF
Resource Reallocation Failure due to LLC Transmission .......... 67
Figure 66 - Measurement Point of Allocation Failures after
Receiving CCCH Request ................................................... 71
Figure 67 - Measurement Point of Allocation Failures after
Receiving PCCCH Request.................................................. 71
Figure 68 - Measurement Point of Allocation Failures (DL GPRS
TBF Exists) ...................................................................... 72
Figure 69 - Measurement Point of Number of GPRS UL TBF
Resource Reallocation Requests due to DL TBF Establishment . 72
Figure 70 - Measurement Point of Number of GPRS UL TBF
Resource Reallocation Requests for Resource Request ........... 74
Figure 71 – Failing to Request for Resource from Database..... 75
Figure 72 – Measurement Point of Number of EGPRS Uplink TBF
Establishment Channel Allocation Failures ............................ 76
Figure 73 –Measurement Point of Number of GPRS DL TBF
Establishment Requests before T3192 Expiration .................. 81
Figure 74 –Measurement Point of GPRS DL TBF Establishment
Using Existing DL TBF Resource.......................................... 81
Figure 75 –Measurement Point of Number of GPRS DL TBF
Establishment Requests on PACCH...................................... 82
Figure 76 –Measurement Point of Number of GPRS DL TBF
Establishment Requests on CCCH/PCCCH............................. 83
Figure 77 –Measurement Point of Number of EGPRS DL TBF
Establishment Requests before T3192 Expiration .................. 84
Figure 78 –Measurement Point of Number of EGPRS DL TBF
Establishment Using Existing DL TBF Resource ..................... 84
Figure 79 –Measurement Point of Number of GPRS DL TBF
Establishment Requests on PACCH...................................... 85
Figure 80 – Normal CCCH/PCCCH DL TBF Establishment Process
..................................................................................... 86
Figure 81 – Measurement Point of Number of GPRS DL Signaling
TBF Release due to N3105 Overflow.................................... 87

266 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B - Figures

Figure 82 – Measurement Point of Number of GPRS DL TBF


Release due to other Reasons ............................................ 87
Figure 83 – Measurement Point of Number of GPRS DL TBF
Forcing Release by Control Plane ........................................ 88
Figure 84 - Measurement Point of Number of GPRS DL TBF
Release due to Instance Suspension.................................... 89
Figure 85 – Measurement Point of Number of EGPRS DL
Signaling TBF Release due to N3105 Overflow ...................... 90
Figure 86 – Measurement Point of Number of EGPRS DL TBF
Release due to other Reasons ............................................ 91
Figure 87 – Measurement Point of Number of EGPRS DL TBF
Forcing Release by Control Plane ........................................ 91
Figure 88 - Measurement Point of Number of Number of EGPRS
DL TBF Release due to Instance Suspension ......................... 92
Figure 89 – Measurement Point on Number of GPRS UL TBF
Reestablishments in Released State (1) ............................... 93
Figure 90 - Measurement Point on Number of GPRS UL TBF
Reestablishments in Released State (2) ............................... 93
Figure 91 - Measurement Point of GPRS UL TBF Establishments
with Existing UL Resource .................................................. 94
Figure 92 – Measurement Point of Number of Requests for
Establishing UL GPRS TBF on PACCH ................................... 95
Figure 93 – Measurement Point on Number of EGPRS UL TBF
Reestablishments in Released State (1) ............................... 96
Figure 94 - Measurement Point on Number of EGPRS UL TBF
Reestablishments in Released State (2) ............................... 96
Figure 95 - Measurement Point of EGPRS UL TBF Establishments
with Existing UL Resource .................................................. 97
Figure 96 – Measurement Point of Number of Requests for
Establishing UL EGPRS TBF on PACCH ................................. 97
Figure 97 – Measurement Point of Number of EGPRS UL TBF
Establishment Requests on CCCH/PCCCH............................. 98
Figure 98 - Measurement Point of Number of GPRS UL TBF
Establishment Requests on CCCH/PCCCH............................. 99
Figure 99 – Radio Access Flow.......................................... 131
Figure 100 – Immediate Assignment Flow .......................... 133
Figure 101 – Internal Handover Flow (Intra-Cell Handover) .. 135
Figure 102 – External Handover Flow ................................ 135
Figure 103 – Immediate Assignment Flow .......................... 137
Figure 104 – Immediate Assignment Occupation Failure Flow 1
................................................................................... 138
Figure 105 – Internal Handover Flow (Intra-Cell Handover, TC Is
Internal) ....................................................................... 139

Confidential and Proprietary Information of ZTE CORPORATION 267


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

Figure 106 – Internal Handover Flow (Intra-Cell Handover,


Channel Type Changed, TC is External) ............................. 140
Figure 107 – External Handover Flow (TC is Internal) .......... 140
Figure 108 – External Handover Flow (TC Is External) ......... 141
Figure 109 – Intra-BSC Handover Occupation Failure Flow ... 141
Figure 110 – Inter-BSC Handover Occupation Failure Flow ... 142
Figure 111 – Immediate Assignment Allocation Failure Flow 2143
Figure 112 – Internal Handover Failure Flow 1 (Intra-Cell
Handover, TC is Internal) ................................................ 144
Figure 113 – External Handover Failure Flow 2 (TC Is Internal)
................................................................................... 144
Figure 114 – Immediate Assignment Failure Flow 3 ............. 145
Figure 115 – Common Assignment Flow (TC Is Internal) ...... 146
Figure 116 – Common Assignment Flow (TC Is External)...... 147
Figure 117 – Common Assignment Failure Flow 1 (TC Is Internal)
................................................................................... 148
Figure 118 – Common Assignment Failure Flow 1 (TC Is Internal)
................................................................................... 150
Figure 119 – Common Assignment Failure Flow 4 (TC Is Internal)
................................................................................... 153
Figure 120 – Idle-State MO Short Message Flow ................. 165
Figure 121 – Idle-State MT Short Message Flow .................. 166
Figure 122 – Call Drop due to T3107 Timeout during Intra-Cell
Handover ...................................................................... 167
Figure 123 – Call Drop due to T3103 Timeout during Inter-Cell
Handover ...................................................................... 168
Figure 124 – Handover Decision ....................................... 177
Figure 125 – BSC-Controlled Inter-Cell Outgoing Handover
Execution ...................................................................... 182
Figure 126 – BSC-Controlled Inter-Cell Outgoing Handover
Success ........................................................................ 183
Figure 127 – MSC-Controlled Outgoing Handover Execution.. 183
Figure 128 – MSC-Controlled Outgoing Handover Success .... 184
Figure 129 – BSC-Controlled Inter-Cell Incoming Handover
Execution ...................................................................... 185
Figure 130 – BSC-Controlled Inter-Cell Incoming Handover
Success ........................................................................ 185
Figure 131 – MSC-Controlled Incoming Handover Execution . 186
Figure 132 – Forced Release Execution .............................. 187
Figure 133 – Queuing Execution ....................................... 187

268 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B - Figures

Figure 134 – MSC-Controlled Incoming Handover Success .... 188


Figure 135 – Intra-Cell Handover Execution ....................... 195
Figure 136 – Intra-Cell Handover Success .......................... 195
Figure 137 – Reporting Measurement Data......................... 196
Figure 138 – Common Assignment Flow 3 (TC is Internal) .... 204
Figure 139 – Measurement Point of Number of Abis Interface
Messages Sent to BTS from BSC ....................................... 211
Figure 140 – Internal Handover Failure Flow 2 (Intra-Cell
Handover, TC Is Internal) ................................................ 213
Figure 141 – External Handover Failure Flow 3 (TC Is Internal)
................................................................................... 213
Figure 142 – Forced Release Execution .............................. 239
Figure 143 – Queuing Execution ....................................... 239
Figure 144 – Forced Handover Execution ........................... 240
Figure 145 – Call Drop due to Inter-BSC Handover Failure.... 242
Figure 146 - Call drops caused by radio link failure during
assignment.................................................................... 254

Confidential and Proprietary Information of ZTE CORPORATION 269


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

This page is intentionally blank.

270 Confidential and Proprietary Information of ZTE CORPORATION


Tables

Table 1 – Manual Summary ..................................................i


Table 2 - Typographical Conventions .................................... iii
Table 3 - Mouse Operation Conventions ................................ iv
Table 4 – Usage Explanation of the Hazardous Substances in
ZXG10 iBSC (V6.20.10)....................................................... v
Table 5 – PS Basic Measurement (BSC) Counters ....................1
Table 6 - PS Basic Measurement (Cell) Counters .....................3
Table 7 – CPU Load Measurement Counters........................ 119
Table 8 – CS Basic Measurement Counters ......................... 121
Table 9 – Configuration Management Information Basic
Measurement Counters ................................................... 255

Confidential and Proprietary Information of ZTE CORPORATION 271


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

This page is intentionally blank.

272 Confidential and Proprietary Information of ZTE CORPORATION


Index

C900030001 ........................1 C900040049 ...................... 34


C900030002 ........................2 C900040050 ...................... 35
C900040001 ...................... 12 C900040051 ...................... 35
C900040002 ...................... 13 C900040052 ...................... 36
C900040003 ...................... 14 C900040053 ...................... 37
C900040004 ...................... 15 C900040054 ...................... 37
C900040005 ...................... 15 C900040055 ...................... 38
C900040006 ...................... 16 C900040056 ...................... 38
C900040007 ...................... 16 C900040057 ...................... 39
C900040008 ...................... 17 C900040058 ...................... 39
C900040009 ...................... 17 C900040059 ...................... 40
C900040010 ...................... 17 C900040060 ...................... 40
C900040011 ...................... 18 C900040061 ...................... 41
C900040012 ...................... 19 C900040062 ...................... 42
C900040013 ...................... 19 C900040063 ...................... 42
C900040014 ...................... 20 C900040064 ...................... 43
C900040015 ...................... 20 C900040065 ...................... 44
C900040016 ...................... 21 C900040066 ...................... 44
C900040017 ...................... 21 C900040067 ...................... 45
C900040018 ...................... 21 C900040068 ...................... 45
C900040019 ...................... 21 C900040069 ...................... 46
C900040020 ...................... 22 C900040070 ...................... 46
C900040021 ...................... 22 C900040071 ...................... 47
C900040022 ...................... 23 C900040072 ...................... 48
C900040023 ...................... 24 C900040073 ...................... 48
C900040024 ...................... 24 C900040074 ...................... 49
C900040025 ...................... 24 C900040075 ...................... 50
C900040026 ...................... 26 C900040076 ...................... 50
C900040027 ...................... 27 C900040077 ...................... 51
C900040028 ...................... 27 C900040078 ...................... 51
C900040029 ...................... 27 C900040079 ...................... 52
C900040030 ...................... 28 C900040080 ...................... 52
C900040031 ...................... 28 C900040081 ...................... 53
C900040032 ...................... 28 C900040082 ...................... 53
C900040033 ...................... 29 C900040083 ...................... 54
C900040034 ...................... 29 C900040084 ...................... 54
C900040035 ...................... 29 C900040085 ...................... 54
C900040036 ...................... 30 C900040086 ...................... 55
C900040037 ...................... 30 C900040087 ...................... 55
C900040038 ...................... 30 C900040088 ...................... 56
C900040039 ...................... 31 C900040089 ...................... 56
C900040040 ...................... 31 C900040090 ...................... 56
C900040041 ...................... 31 C900040091 ...................... 57
C900040042 ...................... 32 C900040092 ...................... 57
C900040043 ...................... 32 C900040093 ...................... 58
C900040044 ...................... 32 C900040094 ...................... 58
C900040045 ...................... 33 C900040095 ...................... 59
C900040046 ...................... 33 C900040096 ...................... 59
C900040047 ...................... 33 C900040097 ...................... 59
C900040048 ...................... 34 C900040098 ...................... 60

Confidential and Proprietary Information of ZTE CORPORATION 273


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900040099 ...................... 60 C900040159....................... 92


C900040100 ...................... 60 C900040160....................... 94
C900040101 ...................... 61 C900040161....................... 94
C900040102 ...................... 61 C900040162....................... 95
C900040103 ...................... 62 C900040163....................... 95
C900040104 ...................... 62 C900040164....................... 96
C900040105 ...................... 62 C900040165....................... 97
C900040106 ...................... 63 C900040166....................... 97
C900040107 ...................... 63 C900040167....................... 98
C900040108 ...................... 63 C900040168....................... 98
C900040109 ...................... 64 C900040169....................... 99
C900040110 ...................... 65 C900040170....................... 99
C900040111 ...................... 65 C900040171....................... 99
C900040112 ...................... 66 C900040172..................... 100
C900040113 ...................... 67 C900040173..................... 100
C900040114 ...................... 67 C900040174..................... 100
C900040115 ...................... 68 C900040175..................... 101
C900040116 ...................... 68 C900040176..................... 101
C900040117 ...................... 69 C900040177..................... 101
C900040118 ...................... 69 C900040178..................... 102
C900040119 ...................... 70 C900040179..................... 102
C900040120 ...................... 70 C900040180..................... 102
C900040121 ...................... 71 C900040181..................... 103
C900040122 ...................... 72 C900040182..................... 103
C900040123 ...................... 72 C900040183..................... 103
C900040124 ...................... 73 C900040184..................... 104
C900040125 ...................... 73 C900040185..................... 104
C900040126 ...................... 74 C900040186..................... 104
C900040127 ...................... 74 C900040187..................... 105
C900040128 ...................... 75 C900040188..................... 105
C900040129 ...................... 75 C900040189..................... 105
C900040130 ...................... 76 C900040190..................... 106
C900040131 ...................... 76 C900040191..................... 106
C900040132 ...................... 77 C900040192..................... 107
C900040133 ...................... 77 C900040193..................... 107
C900040134 ...................... 78 C900040194..................... 107
C900040135 ...................... 78 C900040195..................... 108
C900040136 ...................... 78 C900040196..................... 108
C900040137 ...................... 79 C900040197..................... 108
C900040138 ...................... 79 C900040198..................... 109
C900040139 ...................... 79 C900040199..................... 109
C900040140 ...................... 80 C900040200..................... 109
C900040141 ...................... 80 C900040201..................... 110
C900040142 ...................... 81 C900040202..................... 110
C900040143 ...................... 82 C900040203..................... 110
C900040144 ...................... 82 C900040204..................... 111
C900040145 ...................... 83 C900040205..................... 111
C900040146 ...................... 84 C900040206..................... 111
C900040147 ...................... 85 C900040207..................... 112
C900040148 ...................... 85 C900040208..................... 112
C900040149 ...................... 86 C900040209..................... 112
C900040150 ...................... 87 C900040210..................... 113
C900040151 ...................... 88 C900040211..................... 113
C900040152 ...................... 88 C900040212..................... 113
C900040153 ...................... 89 C900040213..................... 114
C900040154 ...................... 89 C900040214..................... 114
C900040155 ...................... 90 C900040215..................... 114
C900040156 ...................... 91 C900040216..................... 115
C900040157 ...................... 91 C900040217..................... 115
C900040158 ...................... 92 C900040218..................... 115

274 Confidential and Proprietary Information of ZTE CORPORATION


Index

C900040219 .................... 116 C900060052 .................... 166


C900040220 .................... 116 C900060053 .................... 168
C900040221 .................... 116 C900060054 .................... 168
C900040222 .................... 117 C900060055 .................... 169
C900040223 .................... 117 C900060056 .................... 169
C900040224 .................... 117 C900060057 .................... 169
C900040225 .................... 118 C900060058 .................... 170
C900050001 .................... 119 C900060059 .................... 170
C900050002 .................... 120 C900060060 .................... 170
C900060001 .................... 131 C900060061 .................... 171
C900060002 .................... 131 C900060062 .................... 171
C900060003 .................... 132 C900060063 .................... 171
C900060004 .................... 133 C900060064 .................... 171
C900060005 .................... 133 C900060065 .................... 172
C900060006 .................... 134 C900060066 .................... 172
C900060007 .................... 135 C900060067 .................... 172
C900060008 .................... 136 C900060068 .................... 173
C900060009 .................... 136 C900060069 .................... 173
C900060010 .................... 137 C900060070 .................... 173
C900060011 .................... 138 C900060071 .................... 174
C900060012 .................... 138 C900060072 .................... 174
C900060013 .................... 141 C900060073 .................... 174
C900060014 .................... 142 C900060074 .................... 174
C900060015 .................... 142 C900060075 .................... 175
C900060016 .................... 143 C900060076 .................... 175
C900060017 .................... 144 C900060077 .................... 175
C900060018 .................... 145 C900060078 .................... 176
C900060019 .................... 145 C900060079 .................... 176
C900060020 .................... 147 C900060080 .................... 176
C900060021 .................... 148 C900060081 .................... 177
C900060022 .................... 149 C900060082 .................... 177
C900060023 .................... 149 C900060083 .................... 177
C900060024 .................... 149 C900060084 .................... 178
C900060025 .................... 150 C900060085 .................... 178
C900060026 .................... 151 C900060086 .................... 178
C900060027 .................... 151 C900060087 .................... 179
C900060028 .................... 152 C900060088 .................... 179
C900060029 .................... 152 C900060089 .................... 180
C900060030 .................... 153 C900060090 .................... 180
C900060031 .................... 154 C900060091 .................... 180
C900060032 .................... 154 C900060092 .................... 181
C900060033 .................... 155 C900060093 .................... 181
C900060034 .................... 155 C900060094 .................... 182
C900060035 .................... 156 C900060095 .................... 183
C900060036 .................... 156 C900060096 .................... 184
C900060037 .................... 157 C900060097 .................... 184
C900060038 .................... 157 C900060098 .................... 185
C900060039 .................... 158 C900060099 .................... 185
C900060040 .................... 158 C900060100 .................... 186
C900060041 .................... 159 C900060101 .................... 187
C900060042 .................... 159 C900060102 .................... 187
C900060043 .................... 160 C900060103 .................... 188
C900060044 .................... 160 C900060104 .................... 188
C900060045 .................... 161 C900060105 .................... 189
C900060046 .................... 162 C900060106 .................... 189
C900060047 .................... 162 C900060107 .................... 190
C900060048 .................... 163 C900060108 .................... 190
C900060049 .................... 164 C900060109 .................... 190
C900060050 .................... 164 C900060110 .................... 191
C900060051 .................... 165 C900060111 .................... 191

Confidential and Proprietary Information of ZTE CORPORATION 275


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume I)

C900060112 .....................192 C900060172..................... 220


C900060113 .....................192 C900060173..................... 220
C900060114 .....................192 C900060174..................... 220
C900060115 .....................193 C900060175..................... 221
C900060116 .....................193 C900060176..................... 221
C900060117 .....................194 C900060177..................... 222
C900060118 .....................194 C900060178..................... 222
C900060119 .....................194 C900060179..................... 223
C900060120 .....................195 C900060180..................... 223
C900060121 .....................196 C900060181..................... 224
C900060122 .....................197 C900060182..................... 224
C900060123 .....................197 C900060183..................... 225
C900060124 .....................197 C900060184..................... 225
C900060125 .....................198 C900060185..................... 226
C900060126 .....................198 C900060186..................... 226
C900060127 .....................199 C900060187..................... 226
C900060128 .....................199 C900060188..................... 227
C900060129 .....................200 C900060189..................... 227
C900060130 .....................201 C900060190..................... 228
C900060131 .....................201 C900060191..................... 228
C900060132 .....................201 C900060192..................... 229
C900060133 .....................202 C900060193..................... 229
C900060134 .....................202 C900060194..................... 230
C900060135 .....................202 C900060195..................... 230
C900060136 .....................203 C900060196..................... 231
C900060137 .....................203 C900060197..................... 231
C900060138 .....................203 C900060198..................... 232
C900060139 .....................204 C900060199..................... 232
C900060140 .....................204 C900060200..................... 232
C900060141 .....................205 C900060201..................... 233
C900060142 .....................205 C900060202..................... 233
C900060143 .....................206 C900060203..................... 234
C900060144 .....................206 C900060204..................... 234
C900060145 .....................207 C900060205..................... 235
C900060146 .....................207 C900060206..................... 235
C900060147 .....................208 C900060207..................... 236
C900060148 .....................208 C900060208..................... 236
C900060149 .....................209 C900060209..................... 236
C900060150 .....................209 C900060210..................... 237
C900060151 .....................209 C900060211..................... 237
C900060152 .....................210 C900060212..................... 238
C900060153 .....................211 C900060213..................... 238
C900060154 .....................211 C900060214..................... 239
C900060155 .....................211 C900060215..................... 240
C900060156 .....................212 C900060216..................... 240
C900060157 .....................212 C900060217..................... 241
C900060158 .....................213 C900060218..................... 241
C900060159 .....................214 C900060219..................... 241
C900060160 .....................214 C900060220..................... 242
C900060161 .....................215 C900060221..................... 243
C900060162 .....................215 C900060222..................... 244
C900060163 .....................215 C900060223..................... 244
C900060164 .....................216 C900060224..................... 245
C900060165 .....................216 C900060225..................... 245
C900060166 .....................217 C900060226..................... 246
C900060167 .....................217 C900060227..................... 246
C900060168 .....................218 C900060228..................... 246
C900060169 .....................218 C900060229..................... 247
C900060170 .....................219 C900060230..................... 247
C900060171 .....................219 C900060231..................... 248

276 Confidential and Proprietary Information of ZTE CORPORATION


Index

C900060232 .................... 248 C900060244 .................... 253


C900060233 .................... 248 C900060245 .................... 254
C900060234 .................... 249 C900090001 .................... 256
C900060235 .................... 249 C900090002 .................... 256
C900060236 .................... 250 C900090003 .................... 256
C900060237 .................... 250 C900090004 .................... 256
C900060238 .................... 250 C900090005 .................... 257
C900060239 .................... 251 C900090006 .................... 257
C900060240 .................... 251 C900090007 .................... 257
C900060241 .................... 252 C900090008 .................... 257
C900060242 .................... 252 C900090009 .................... 258
C900060243 .................... 253

Confidential and Proprietary Information of ZTE CORPORATION 277


ZXG10 iBSC
Base Station Controller
Performance Counter Reference (Volume II)

Version 6.20.10

ZTE CORPORATION
ZTE Plaza, Keji Road South,
Hi-Tech Industrial Park,
Nanshan District, Shenzhen,
P. R. China
518057
Tel: (86) 755 26771900 800-9830-9830
Fax: (86) 755 26772236
URL: http://support.zte.com.cn
E-mail: doc@zte.com.cn
This page is intentionally blank.
Contents

About This Manual ............................................................ i


Purpose ................................................................................ i
Intended Audience ................................................................. i
Prerequisite Skill and Knowledge .............................................. i
What Is in This Manual ........................................................... i
Related Documentation.......................................................... ii
Conventions ........................................................................ iii
How to Get in Touch ............................................................. iv

Declaration of RoHS Compliance................................... vii

Chapter 1.......................................................................... 9

Downlink Data TBF Measurement ................................... 9


Overview ............................................................................. 9
DL Data TBF Measurement Counter Index................................. 9
C901000001 ...................................................................... 11
C901000005 ...................................................................... 11
C901000006 ...................................................................... 12
C901000009 ...................................................................... 12
C901000010 ...................................................................... 13
C901000011 ...................................................................... 14
C901000012 ...................................................................... 15
C901000013 ...................................................................... 16
C901000014 ...................................................................... 17
C901000015 ...................................................................... 17
C901000023 ...................................................................... 18
C901000027 ...................................................................... 18
C901000028 ...................................................................... 19
C901000031 ...................................................................... 19
C901000032 ...................................................................... 19
C901000033 ...................................................................... 20
C901000034 ...................................................................... 20
C901000035.......................................................................21
C901000036.......................................................................21
C901000037.......................................................................22
C901000045.......................................................................23
C901000046.......................................................................23
C901000047.......................................................................24
C901000048.......................................................................24
C901000050.......................................................................24
C901000052.......................................................................25
C901000058.......................................................................25

Chapter 2........................................................................ 27

Uplink Data TBF Measurement ......................................27


Overview ...........................................................................27
UL Data TBF Measurement Counter Index ...............................27
C901010001.......................................................................28
C901010002.......................................................................29
C901010006.......................................................................30
C901010007.......................................................................30
C901010010.......................................................................30
C901010011.......................................................................31
C901010012.......................................................................32
C901010013.......................................................................33
C901010014.......................................................................34
C901010022.......................................................................34
C901010023.......................................................................35
C901010027.......................................................................35
C901010028.......................................................................36
C901010031.......................................................................36
C901010032.......................................................................37
C901010033.......................................................................38
C901010034.......................................................................38
C901010035.......................................................................40
C901010043.......................................................................40
C901010044.......................................................................40
C901010045.......................................................................41
C901010046.......................................................................41
C901010048.......................................................................41
C901010050.......................................................................42
C901010056 ...................................................................... 42

Chapter 3........................................................................ 45

Data Flow Measurement................................................ 45


Overview ........................................................................... 45
Data Flow Measurement Counter Index .................................. 45
C901020001 ...................................................................... 46
C901020002 ...................................................................... 47
C901020003 ...................................................................... 47
C901020004 ...................................................................... 48
C901020005 ...................................................................... 48
C901020006 ...................................................................... 49
C901020007 ...................................................................... 49
C901020008 ...................................................................... 50
C901020009 ...................................................................... 50
C901020014 ...................................................................... 51
C901020019 ...................................................................... 52
C901020020 ...................................................................... 52
C901020021 ...................................................................... 53
C901020022 ...................................................................... 53
C901020023 ...................................................................... 54
C901020024 ...................................................................... 54
C901020025 ...................................................................... 55
C901020026 ...................................................................... 55
C901020031 ...................................................................... 56
C901020034 ...................................................................... 56
C901020041 ...................................................................... 57
C901020044 ...................................................................... 57
C901020050 ...................................................................... 58

Chapter 4........................................................................ 59

Uplink/Downlink RLC Statistic Measurement............... 59


Overview ........................................................................... 59
Uplink/Downlink RLC Statistic Measurement Counter Index ....... 61
C901030041 ...................................................................... 61
C901030042 ...................................................................... 62
C901030083 ...................................................................... 62
C901030084 ...................................................................... 62
C901030085 ...................................................................... 63
C901030086.......................................................................63
C901030087.......................................................................63
C901030088.......................................................................64
C901030089.......................................................................64
C901030090.......................................................................65
C901030091.......................................................................65
C901030092.......................................................................66
C901030093.......................................................................66
C901030094.......................................................................67
C901030095.......................................................................67

Chapter 5........................................................................ 69

PS Resource Used Statistic Measurement.....................69


Overview ...........................................................................69
PS Resource Used Statistic Measurement Counters...................69
C901040001.......................................................................70
C901040002.......................................................................71
C901040004.......................................................................71
C901040005.......................................................................71
C901040006.......................................................................72
C901040009.......................................................................72
C901040010.......................................................................73
C901040011.......................................................................73
C901040012.......................................................................74
C901040013.......................................................................74
C901040014.......................................................................75
C901040018.......................................................................75
C901040019.......................................................................76
C901040020.......................................................................77
C901040021.......................................................................77
C901040022.......................................................................77
C901040023.......................................................................78
C901040024.......................................................................78
C901040025.......................................................................79
C901040026.......................................................................79
C901040027.......................................................................80
C901040028.......................................................................80
C901040029.......................................................................80
C901040030.......................................................................80
C901040031 ...................................................................... 81
C901040032 ...................................................................... 81
C901040033 ...................................................................... 82
C901040034 ...................................................................... 82
C901040035 ...................................................................... 82
C901040036 ...................................................................... 83
C901040037 ...................................................................... 83
C901040038 ...................................................................... 83

Chapter 6........................................................................ 85

RMM Assignment Measurement.................................... 85


Overview ........................................................................... 85
RMM Assignment Measurement Counter Index ........................ 85
C901050001 ...................................................................... 88
C901050002 ...................................................................... 88
C901050003 ...................................................................... 89
C901050004 ...................................................................... 90
C901050005 ...................................................................... 91
C901050006 ...................................................................... 92
C901050007 ...................................................................... 93
C901050008 ...................................................................... 94
C901050009 ...................................................................... 94
C901050010 ...................................................................... 95
C901050011 ...................................................................... 96
C901050012 ...................................................................... 97
C901050013 ...................................................................... 97
C901050014 ...................................................................... 98
C901050015 ...................................................................... 98
C901050016 ...................................................................... 99
C901050017 ...................................................................... 99
C901050018 .................................................................... 100
C901050019 .................................................................... 100
C901050020 .................................................................... 100
C901050021 .................................................................... 101
C901050022 .................................................................... 101
C901050023 .................................................................... 101
C901050024 .................................................................... 102
C901050025 .................................................................... 102
C901050026 .................................................................... 103
C901050027..................................................................... 103
C901050028..................................................................... 103
C901050029..................................................................... 104
C901050030..................................................................... 104
C901050031..................................................................... 104
C901050032..................................................................... 105
C901050033..................................................................... 105
C901050034..................................................................... 106
C901050035..................................................................... 106
C901050036..................................................................... 107
C901050037..................................................................... 108
C901050038..................................................................... 108
C901050039..................................................................... 108
C901050040..................................................................... 109
C901050041..................................................................... 109
C901050042..................................................................... 110
C901050043..................................................................... 111
C901050044..................................................................... 112
C901050045..................................................................... 112
C901050046..................................................................... 113
C901050047..................................................................... 114
C901050048..................................................................... 115
C901050049..................................................................... 115

Chapter 7......................................................................117

Handover Cause Measurement....................................117


Overview ......................................................................... 117
Handover Cause Measurement Counter Index........................ 117
C901060001..................................................................... 120
C901060002..................................................................... 120
C901060003..................................................................... 121
C901060004..................................................................... 121
C901060005..................................................................... 121
C901060006..................................................................... 122
C901060007..................................................................... 122
C901060008..................................................................... 122
C901060009..................................................................... 123
C901060010..................................................................... 123
C901060011..................................................................... 124
C901060012 .................................................................... 124
C901060013 .................................................................... 125
C901060014 .................................................................... 125
C901060015 .................................................................... 126
C901060016 .................................................................... 126
C901060017 .................................................................... 127
C901060018 .................................................................... 127
C901060019 .................................................................... 127
C901060020 .................................................................... 128
C901060021 .................................................................... 129
C901060022 .................................................................... 129
C901060023 .................................................................... 129
C901060024 .................................................................... 130
C901060035 .................................................................... 130
C901060036 .................................................................... 130
C901060037 .................................................................... 131
C901060038 .................................................................... 131
C901060039 .................................................................... 132
C901060040 .................................................................... 132
C901060041 .................................................................... 132
C901060042 .................................................................... 133
C901060043 .................................................................... 133
C901060044 .................................................................... 134
C901060045 .................................................................... 134
C901060046 .................................................................... 134
C901060058 .................................................................... 135
C901060059 .................................................................... 135
C901060060 .................................................................... 136
C901060061 .................................................................... 136
C901060062 .................................................................... 136
C901060063 .................................................................... 137
C901060064 .................................................................... 137
C901060065 .................................................................... 137
C901060066 .................................................................... 138
C901060067 .................................................................... 138
C901060068 .................................................................... 139
C901060069 .................................................................... 139
C901060070 .................................................................... 140
C901060071 .................................................................... 140
C901060072..................................................................... 140
C901060073..................................................................... 141
C901060074..................................................................... 141
C901060075..................................................................... 142
C901060076..................................................................... 142
C901060077..................................................................... 142
C901060078..................................................................... 143

Chapter 8......................................................................145

RMM Call Drop Measurement ......................................145


Overview ......................................................................... 145
RMM Call Drop Measurement Counter Index .......................... 145
C901070001..................................................................... 149
C901070002..................................................................... 149
C901070003..................................................................... 150
C901070004..................................................................... 151
C901070005..................................................................... 151
C901070007..................................................................... 152
C901070008..................................................................... 153
C901070009..................................................................... 153
C901070010..................................................................... 154
C901070011..................................................................... 154
C901070012..................................................................... 155
C901070014..................................................................... 155
C901070015..................................................................... 155
C901070017..................................................................... 157
C901070018..................................................................... 157
C901070019..................................................................... 158
C901070021..................................................................... 159
C901070022..................................................................... 160
C901070023..................................................................... 160
C901070024..................................................................... 161
C901070025..................................................................... 162
C901070026..................................................................... 162
C901070028..................................................................... 162
C901070029..................................................................... 163
C901070030..................................................................... 163
C901070031..................................................................... 164
C901070032..................................................................... 164
C901070033 .................................................................... 165
C901070035 .................................................................... 165
C901070036 .................................................................... 165
C901070038 .................................................................... 166
C901070039 .................................................................... 166
C901070040 .................................................................... 167
C901070042 .................................................................... 167
C901070043 .................................................................... 168
C901070044 .................................................................... 168
C901070045 .................................................................... 168
C901070046 .................................................................... 169
C901070047 .................................................................... 169
C901070049 .................................................................... 170
C901070053 .................................................................... 170
C901070054 .................................................................... 171
C901070055 .................................................................... 172
C901070056 .................................................................... 173
C901070057 .................................................................... 173
C901070058 .................................................................... 174
C901070059 .................................................................... 174
C901070060 .................................................................... 174
C901070061 .................................................................... 175
C901070062 .................................................................... 175
C901070063 .................................................................... 175
C901070064 .................................................................... 176
C901070065 .................................................................... 176
C901070066 .................................................................... 177
C901070067 .................................................................... 177
C901070068 .................................................................... 177
C901070069 .................................................................... 178
C901070070 .................................................................... 178
C901070071 .................................................................... 178
C901070072 .................................................................... 179
C901070073 .................................................................... 179
C901070074 .................................................................... 179
C901070075 .................................................................... 180
C901070076 .................................................................... 180
C901070077 .................................................................... 180
C901070078 .................................................................... 181
C901070079..................................................................... 181
C901070080..................................................................... 181
C901070081..................................................................... 182
C901070082..................................................................... 182
C901070083..................................................................... 183
C901070084..................................................................... 183
C901070085..................................................................... 183
C901070086..................................................................... 184
C901070087..................................................................... 184
C901070088..................................................................... 184

Chapter 9......................................................................187

Radio Resource Availability Measurement..................187


Overview ......................................................................... 187
Radio Resource Availability Measurement Counter Index ......... 187
C901080003..................................................................... 188
C901080004..................................................................... 189
C901080006..................................................................... 189
C901080008..................................................................... 190
C901080011..................................................................... 190
C901080012..................................................................... 190
C901080014..................................................................... 191
C901080016..................................................................... 191
C901080017..................................................................... 192
C901080018..................................................................... 193
C901080022..................................................................... 193
C901080024..................................................................... 194
C901080025..................................................................... 194
C901080026..................................................................... 195
C901080027..................................................................... 196
C901080030..................................................................... 196
C901080032..................................................................... 197

Chapter 10....................................................................199

General Handover Measurement.................................199


Overview ......................................................................... 199
General Handover Measurement Counter Index ..................... 199
C901090001..................................................................... 206
C901090004..................................................................... 207
C901090005 .................................................................... 208
C901090006 .................................................................... 209
C901090007 .................................................................... 209
C901090008 .................................................................... 210
C901090011 .................................................................... 210
C901090013 .................................................................... 211
C901090015 .................................................................... 212
C901090017 .................................................................... 212
C901090020 .................................................................... 213
C901090021 .................................................................... 214
C901090022 .................................................................... 215
C901090023 .................................................................... 215
C901090024 .................................................................... 216
C901090025 .................................................................... 216
C901090026 .................................................................... 217
C901090027 .................................................................... 217
C901090028 .................................................................... 218
C901090030 .................................................................... 218
C901090032 .................................................................... 218
C901090034 .................................................................... 219
C901090037 .................................................................... 219
C901090038 .................................................................... 220
C901090039 .................................................................... 220
C901090040 .................................................................... 221
C901090041 .................................................................... 221
C901090042 .................................................................... 222
C901090043 .................................................................... 222
C901090044 .................................................................... 223
C901090045 .................................................................... 223
C901090046 .................................................................... 224
C901090047 .................................................................... 224
C901090048 .................................................................... 224
C901090049 .................................................................... 225
C901090052 .................................................................... 225
C901090053 .................................................................... 226
C901090054 .................................................................... 226
C901090055 .................................................................... 227
C901090058 .................................................................... 227
C901090059 .................................................................... 227
C901090060..................................................................... 228
C901090061..................................................................... 228
C901090062..................................................................... 229
C901090063..................................................................... 229
C901090064..................................................................... 229
C901090065..................................................................... 230
C901090066..................................................................... 230
C901090067..................................................................... 231
C901090068..................................................................... 231
C901090069..................................................................... 231
C901090072..................................................................... 232
C901090073..................................................................... 232
C901090074..................................................................... 233
C901090075..................................................................... 233
C901090078..................................................................... 233
C901090079..................................................................... 234
C901090080..................................................................... 234
C901090081..................................................................... 235
C901090084..................................................................... 235
C901090085..................................................................... 235
C901090086..................................................................... 236
C901090087..................................................................... 236
C901090090..................................................................... 237
C901090091..................................................................... 237
C901090092..................................................................... 237
C901090093..................................................................... 238
C901090096..................................................................... 238
C901090097..................................................................... 239
C901090098..................................................................... 239
C901090099..................................................................... 239
C901090102..................................................................... 240
C901090103..................................................................... 240
C901090104..................................................................... 241
C901090105..................................................................... 241
C901090108..................................................................... 242
C901090109..................................................................... 242
C901090110..................................................................... 242
C901090111..................................................................... 243
C901090112..................................................................... 243
C901090113 .................................................................... 244
C901090114 .................................................................... 244
C901090115 .................................................................... 244
C901090116 .................................................................... 245
C901090117 .................................................................... 245
C901090118 .................................................................... 246
C901090119 .................................................................... 246
C901090120 .................................................................... 246
C901090121 .................................................................... 247
C901090122 .................................................................... 248
C901090123 .................................................................... 248
C901090124 .................................................................... 249
C901090125 .................................................................... 249
C901090126 .................................................................... 249
C901090127 .................................................................... 250
C901090128 .................................................................... 250
C901090129 .................................................................... 250
C901090130 .................................................................... 251
C901090131 .................................................................... 251
C901090132 .................................................................... 252
C901090133 .................................................................... 252
C901090134 .................................................................... 252
C901090135 .................................................................... 253
C901090136 .................................................................... 253
C901090137 .................................................................... 253
C901090138 .................................................................... 254
C901090139 .................................................................... 254
C901090140 .................................................................... 255
C901090141 .................................................................... 255
C901090142 .................................................................... 255
C901090145 .................................................................... 256
C901090148 .................................................................... 256
C901090149 .................................................................... 257
C901090150 .................................................................... 257
C901090151 .................................................................... 258
C901090152 .................................................................... 258
C901090153 .................................................................... 259
C901090154 .................................................................... 259
C901090155 .................................................................... 260
C901090156..................................................................... 261
C901090157..................................................................... 262
C901090158..................................................................... 262
C901090159..................................................................... 263
C901090160..................................................................... 264
C901090161..................................................................... 265
C901090162..................................................................... 265
C901090163..................................................................... 266
C901090164..................................................................... 267
C901090165..................................................................... 268
C901090166..................................................................... 269
C901090167..................................................................... 270
C901090168..................................................................... 270
C901090169..................................................................... 271
C901090170..................................................................... 271
C901090171..................................................................... 272
C901090172..................................................................... 272
C901090173..................................................................... 273
C901090174..................................................................... 273
C901090175..................................................................... 274
C901090176..................................................................... 274
C901090177..................................................................... 274
C901090178..................................................................... 275
C901090179..................................................................... 275

Chapter 11....................................................................277

Adjacent Cell Handover Measurement ........................277


Overview ......................................................................... 277
Adjacent Cell Handover Measurement Counter Index .............. 277
C901100001..................................................................... 278
C901100002..................................................................... 279
C901100003..................................................................... 279
C901100004..................................................................... 280
C901100005..................................................................... 280
C901100006..................................................................... 280
C901100007..................................................................... 281
C901100008..................................................................... 281
C901100009..................................................................... 282
C901100010..................................................................... 282
C901100011 .................................................................... 282
C901100012 .................................................................... 283
C901100013 .................................................................... 283
C901100014 .................................................................... 284
C901100015 .................................................................... 284
C901100016 .................................................................... 284
C901100017 .................................................................... 285

Chapter 12.................................................................... 287

Radio Access Measurement.........................................287


Overview ......................................................................... 287
Radio Access Measurement Counter Index ............................ 288
C901110001 .................................................................... 289
C901110003 .................................................................... 290
C901110006 .................................................................... 290
C901110008 .................................................................... 290
C901110009 .................................................................... 291
C901110010 .................................................................... 291
C901110011 .................................................................... 291
C901110012 .................................................................... 292
C901110013 .................................................................... 292
C901110014 .................................................................... 292
C901110015 .................................................................... 293
C901110016 .................................................................... 293
C901110017 .................................................................... 293
C901110018 .................................................................... 294
C901110019 .................................................................... 294
C901110020 .................................................................... 294
C901110021 .................................................................... 295
C901110022 .................................................................... 295
C901110023 .................................................................... 295
C901110024 .................................................................... 296
C901110026 .................................................................... 296
C901110027 .................................................................... 296
C901110028 .................................................................... 297
C901110029 .................................................................... 297
C901110031 .................................................................... 297
C901110032 .................................................................... 298
C901110033 .................................................................... 298
Chapter 13....................................................................299

Radio Measurement .....................................................299


Overview ......................................................................... 299
Radio Measurement Counter Index ...................................... 299
C901120001..................................................................... 301
C901120002..................................................................... 301
C901120003..................................................................... 302
C901120004..................................................................... 302
C901120005..................................................................... 302
C901120006..................................................................... 303
C901120007..................................................................... 303
C901120008..................................................................... 303
C901120009..................................................................... 304
C901120010..................................................................... 304
C901120011..................................................................... 304
C901120012..................................................................... 305
C901120013..................................................................... 305
C901120014..................................................................... 305
C901120015..................................................................... 306
C901120016..................................................................... 306
C901120017..................................................................... 306
C901120018..................................................................... 307
C901120024..................................................................... 307
C901120030..................................................................... 307
C901120031..................................................................... 308
C901120032..................................................................... 308
C901120033..................................................................... 308
C901120034..................................................................... 308
C901120035..................................................................... 309
C901120052..................................................................... 309
C901120053..................................................................... 309
C901120054..................................................................... 309
C901120055..................................................................... 309
C901120056..................................................................... 310
C901120057..................................................................... 310
C901120058..................................................................... 310
C901120059..................................................................... 310
C901120060..................................................................... 311
C901120061 .................................................................... 311
C901120062 .................................................................... 311

Appendix A ................................................................... 313

Abbreviations ............................................................... 313

Appendix B ................................................................... 317

Figures.......................................................................... 317

Tables ........................................................................... 325

Index ............................................................................ 327


This page is intentionally blank.
About This Manual

Purpose
This manual provides procedures and guidelines that support the
operation of the ZXG10 iBSC (V6.20.10).

Intended Audience
This manual is intended for engineers and technicians who
perform operation activities on the ZXG10 iBSC (V6.20.10).

Prerequisite Skill and Knowledge


To use this manual effectively, users should have a general
understanding of wireless telecommunications technology.
Familiarity with the following is helpful:
„ ZXG10 system and its various components
„ GSM BSS components and processes
„ Local operating procedures

What Is in This Manual


This manual contains the following sections:

TABLE 1 – M ANUAL SUMMARY

Section Summary
Chapter 1, Downlink Introduces the detailed information about
Data TBF Measurement counters related to downlink data TBF
measurement.
Chapter 2, Uplink Data Introduces the detailed information about
TBF Measurement counters related to uplink data TBF
measurement.
Chapter 3, Data Flow Introduces the detailed information about
Measurement counters related to data flow

Confidential and Proprietary Information of ZTE CORPORATION i


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Section Summary
measurement.
Chapter 4, Introduces the detailed information about
Uplink/Downlink RLC counters related to uplink/downlink RLC
Statistic Measurement statistic measurement.
Chapter 5, PS Resource Introduces the detailed information about
Used Statistic counters related to PS resource used
Measurement statistic measurement
Chapter 6, RMM Introduces the detailed information about
Assignment counters related to RMM assignment
Measurement measurement
Chapter 7, Handover Introduces the detailed information about
Cause Measurement counters related to handover cause
measurement
Chapter 8, RMM Call Introduces the detailed information about
Drop Measurement counters related to RMM call drop
measurement
Chapter 9, Radio Introduces the detailed information about
Resource Availability counters related to radio resource
Measurement availability measurement
Chapter 10, General Introduces the detailed information about
Handover Measurement counters related to general handover
measurement.
Chapter 11, Adjacent Introduces the detailed information about
Cell Handover counters related to adjacent cell handover
Measurement measurement.
Chapter 12, Radio Introduces the detailed information about
Access Measurement counters related to radio access
measurement.
Chapter 13, Radio Introduces the detailed information about
Measurement counters related to radio measurement.
Appendix A, Lists all the abbreviations used in this
Abbreviations manual.
Appendix B, Figures Lists all the figures and tables used in this
and Tables manual.
Index Index of terms and definitions appeared in
this manual.

Related Documentation
The following documentation is related to this manual:
„ ZXG10 iBSC (V6.20.10) Base Station Controller
Documentation Guide
„ ZXG10 iBSC (V6.20.10) Base Station Controller System
Description

ii Confidential and Proprietary Information of ZTE CORPORATION


About This Manual

„ ZXG10 iBSC (V6.20.10) Base Station Controller Hardware


Description
„ ZXG10 iBSC (V6.20.10) Base Station Controller Hardware
Installation Guide
„ ZXG10 iBSC (V6.20.10) Base Station Controller Routine
Maintenance
„ ZXG10 iBSC (V6.20.10) Base Station Controller Emergency
Maintenance
„ ZXG10 iBSC (V6.20.10) Base Station Controller
Troubleshooting
„ ZXG10 iBSC (V6.20.10) Base Station Controller KPI
Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem OMM
Software Installation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Initial
Configuration Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Feature
Configuration Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Radio
Parameters Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Ground
Parameters Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem MML
Command Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Signaling
Tracing Operation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Diagnosis
Test Operation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Alarm
Handling Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Notification
Handling Reference

Conventions
Typographical ZTE documents employ the following typographical conventions.
Conventions
TABLE 2 - TYPOGRAPHIC AL CONVENTIONS

Typeface Meaning
Italics References to other Manuals and documents.
“Quotes” Links on screens.
Bold Menus, menu options, function names, input

Confidential and Proprietary Information of ZTE CORPORATION iii


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Typeface Meaning
fields, radio button names, check boxes, drop-
down lists, dialog box names, window names.
CAPS Keys on the keyboard and buttons on screens
and company name.
Constant width Text that you type, program code, files and
directory names, and function names.
[] Optional parameters.
{} Mandatory parameters.
| Select one of the parameters that are delimited
by it.
Note: Provides additional information about a
certain topic.
Checkpoint: Indicates that a particular step needs
to be checked before proceeding further.
Tip: Indicates a suggestion or hint to make things
easier or more productive for the reader.

Mouse TABLE 3 - MOUSE OPERATION CONVENTIONS


Operation
Conventions Typeface Meaning
Click Refers to clicking the primary mouse button (usually
the left mouse button) once.
Double-click Refers to quickly clicking the primary mouse button
(usually the left mouse button) twice.
Right-click Refers to clicking the secondary mouse button
(usually the right mouse button) once.
Drag Refers to pressing and holding a mouse button and
moving the mouse.

How to Get in Touch


The following sections provide information on how to obtain
support for the documentation and the software.
Customer If you have problems, questions, comments, or suggestions
Support regarding your product, contact us by e-mail at
support@zte.com.cn. You can also call our customer support
center at (86) 755 26771900 and (86) 800-9830-9830.
Documentation ZTE welcomes your comments and suggestions on the quality
Support and usefulness of this document. For further questions,
comments, or suggestions on the documentation, you can
contact us by e-mail at doc@zte.com.cn; or you can fax your
comments and suggestions to (86) 755 26772236. You can also
browse our website at http://support.zte.com.cn, which contains

iv Confidential and Proprietary Information of ZTE CORPORATION


About This Manual

various interesting subjects like documentation, knowledge base,


forum and service request.

Confidential and Proprietary Information of ZTE CORPORATION v


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

vi Confidential and Proprietary Information of ZTE CORPORATION


Declaration of RoHS
Compliance

To minimize the environmental impact and take more


responsibility to the earth we live, this document shall serve as
formal declaration that the ZXG10 iBSC (V6.20.10) Base Station
Controller manufactured by ZTE CORPORATION is in compliance
with the Directive 2002/95/EC of the European Parliament -
RoHS (Restriction of Hazardous Substances) with respect to the
following substances:
„ Lead (Pb)
„ Mercury (Hg)
„ Cadmium (Cd)
„ Hexavalent Chromium (Cr (VI))
„ PolyBrominated Biphenyls (PBB’s)
„ PolyBrominated Diphenyl Ethers (PBDE’s)
The usage of the above substances in ZXG10 iBSC (V6.20.10) is
explained in the Table 4.

TABLE 4 – USAGE EXPLANATION OF THE HAZ ARDOUS SUBSTANCES IN ZXG10


IBSC (V6.20.10)

Hazardous substances
Names of Parts
Pb Hg Cd Cr(VI) PBB’s PBDE’s

System × 0 0 0 0 0
Cables and Assembly 0 0 0 0 0 0
Auxiliary Equipment × × × × × ×

Table Explanation:
0: The usage of the substance in all of the components is less
than the allowed values given by 2002/95/EC standard.
×: The usage of the substance in at least one of the components
is beyond the allowed values given by 2002/95/EC standard.

Confidential and Proprietary Information of ZTE CORPORATION vii


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

The ZXG10 iBSC (V6.20.10) Base Station Controller


manufactured by ZTE CORPORATION meet the requirements of
EU 2002/95/EC; however, some assemblies are customized to
client specifications. Addition of specialized, customer-specified
materials or processes, which do not meet the requirements of
EU 2002/95 /EC, may negate RoHS compliance of the assembly.
To guarantee compliance of the assembly, the need for
compliant product must be communicated to ZTE CORPORATION
in written form.
This declaration is issued based on our current level of
knowledge. Since conditions of use are outside our control, ZTE
CORPORATION makes no warranties, express or implied, and
assumes no liability in connection with the use of this
information.

viii Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1

Downlink Data TBF


Measurement

This chapter contains detailed information about counters


related to random access measurement.
Downlink (DL) data TBF measurement collects information of the
DL TBF establishment and release in a cell. It includes GPRS TBF
and EGPRS TBF. Some measurement is made for signaling TBF
and data TBF respectively. This chapter gives detailed
information about the DL TBF measurement.

Overview
DL TBF process comprises establishment, transmission and
release of the DL TBF.
The establishment includes the DL TBF establishment on CCCH,
PCCCH and PACCH.
The release includes normal release and abnormal release of the
DL TBF. Abnormal release is used to judge the running of PS
service so as to make adjustment.
DL transmission measurement mainly focuses on the connecting
time of the DL TBF and the number of co-existing DL TBFs.

DL Data TBF Measurement Counter


Index
Table 5 lists counters related to DL data TBF measurement.

TABLE 5 - DL DATA TBF MEASUREMENT COUNTERS

Counter ID What It Counts


C901000001 Number of GPRS DL TBF resumption in delay state

Confidential and Proprietary Information of ZTE CORPORATION 9


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter ID What It Counts


Number of GPRS DL TBF establishment failure on
C901000005
PACCH due to time out
Number of GPRS DL TBF establishment failure on
C901000006
PACCH due to other reasons
Number of GPRS DL TBF establishment failure on
C901000009
CCCH/PCCCH due to time out
Number of GPRS DL TBF establishment failure on
C901000010
CCCH/PCCCH due to other reasons
Number of GPRS DL TBF establishment execution on
C901000011
CCCH/PCCCH
Number of GPRS DL TBF establishment execution
C901000012
failure on CCCH/PCCCH due to polling failed
Number of GPRS DL TBF establishment execution
C901000013
success on CCCH/PCCCH due to polling succeeded
Number of GPRS DL TBF establishment success on
C901000014
CCCH/PCCCH
C901000015 Number of GPRS DL TBF normal release
C901000023 Number of EGPRS DL TBF resumption in delay state
Number of EGPRS DL TBF establishment failure on
C901000027
PACCH due to time out
Number of EGPRS DL TBF establishment failure on
C901000028
PACCH due to other reasons
Number of EGPRS DL TBF establishment failure on
C901000031
CCCH/PCCCH due to time out
Number of EGPRS DL TBF establishment failure on
C901000032
CCCH/PCCCH due to other reasons
Number of EGPRS DL TBF establishment execution
C901000033
on CCCH/PCCCH
Number of EGPRS DL TBF establishment execution
C901000034
failure on CCCH/PCCCH due to polling failed
Number of EGPRS DL TBF establishment execution
C901000035
success on CCCH/PCCCH due to polling succeeded
Number of EGPRS DL TBF establishment success on
C901000036
CCCH/PCCCH
C901000037 Number of EGPRS DL TBF normal release
C901000045 Time of GPRS DL TBF connection
C901000046 Time of EGPRS DL TBF connection
C901000047 Time of DL signaling TBF connection
Max number of GPRS DL TBF simultaneous
C901000048
establishment
Max number of EGPRS DL TBF simultaneous
C901000050
establishment
C901000052 Number of GPRS DL signaling TBF normal release

10 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Downlink Data TBF Measurement

Counter ID What It Counts


C901000058 Number of EGPRS DL signaling TBF normal release

C901000001
Definition Number of GPRS DL TBF resumption in delay state
Description This counter counts the number of retransmissions after the DL
GPRS TBF finishes LLC frame transmission and receives new LLC
frames.
Measurement When the DL GPRS TBF transmits all LLC frames and receives
Point new LLC frames before transmitting the DL RLC block (FBI=1),
this counter increments. The measurement point is A, as shown
in Figure 1.

FIGURE 1 - MEASUREMENT POINT OF NUMBER OF RESUMPTION FOR GPRS DL


TBF IN DELAY STATE

MS BSC SGSN
LLC Frame
RLC Block
LLC Frame
RLC Block
RLC Block LLC frames have been
transmitted and RLC
block with FBI=1 is not
transmitted.
LLC Frame

RLC Block A

Unit Times

C901000005
Definition Number of GPRS DL TBF establishment failure on PACCH due to
time out
Description In the UL transmission state, when SGSN DL LLC frame arrives,
the DL TBF transmission should be established. If there is no
reserved DL resource, the user plane will ask the control plane
to allocate resource. This counter counts the number of non-
responses from the control plane in this case.
Measurement When the BSC sends DL Assign Request, the timer waiting for
Point response is triggered. The counter increments if the timer
expires. The measurement point is A, as shown in Figure 2.

Confidential and Proprietary Information of ZTE CORPORATION 11


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 2 – NUMBER OF REQUEST FAILURES FOR ESTABLISHING GPRS ON


P AC C H ( N O R E S P O N S E F R O M C O N T R O L P L A N E )

MS BSC user plane BSC control plane SGSN

RLC Block
RLC Block
LLC Frame
(no record DL resource )

DL Assign Request

Timeout

Unit Times

C901000006
Definition Number of GPRS DL TBF establishment failure on PACCH due to
other reasons
Description This counter counts the number of TBF establishment failures
caused by other reasons than non-responses from the control
plane when PACCH of GPRS TBF tries to establish DL TBF. The
other reasons here include failed transmission of assignment
messages and failed creation of DL RLC instances.
Measurement When PACCH fails to send the assignment messages or fails to
Point create DL RLC instances, the counter increments.
Unit Times

C901000009
Definition Number of GPRS DL TBF establishment failure on CCCH/PCCCH
due to time out
Description When MS is in the idle state, after BSC receives DL LLC frames
from SGSN, BSC should originate DL TBF establishment assigned
on CCCH/PCCCH. The user plane asks the control plane for radio
resources. If the user plane fails to receive the resources within
the specified time or it receives the message of assignment
failure, it indicates that the DL TBF establishment fails.
Measurement During the DL GPRS TBF establishment on CCCH/PCCCH, if there
Point is no radio resource assigned by the control plane within the
specified time, this counter increments. The measurement point
is A, as shown in Figure 3 and Figure 4.

12 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Downlink Data TBF Measurement

FIGURE 3 – FAILURES FOR ESTABLISHING DL GPRS TBF ON CCCH/PCCCH


(1)

FIGURE 4 – FAILURES FOR ESTABLISHING DL GPRS TBF ON CCCH/PCCCH


(2)

Unit Times

C901000010
Definition Number of GPRS DL TBF establishment failure on CCCH/PCCCH
due to other reasons
Description When MS is in the idle state, after BSC receives DL LLC frames
from SGSN, BSC should originate DL TBF establishment assigned
on CCCH/PCCCH. The user plane sends a DL establishment
request to the control plane. If it receives the instance release
message from the control plane or fails to create DL RLC
instance after receiving the resource assignment message, it
indicates that the DL TBF establishment fails.
Measurement During the DL GRPS TBF establishment on CCCH/PCCCH, after
Point the user plane sends the request to the control plane, if it
receives the instance release message from the control plane or
fails to create DL RLC instance after receiving the resource
assignment message, this counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 13


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901000011
Definition Number of GPRS DL TBF establishment execution on
CCCH/PCCCH
Description When MS is in the idle state, after BSC receives DL LLC frames
from SGSN, BSC should originate DL TBF establishment assigned
on CCCH/PCCCH. After receiving the request from the user plane,
the control plane assigns the resource, sends the assignment
message on CCCH/PCCCH, and informs the user plane. The
initial timing advance is acquired then and the DL TBF
establishment starts.
In the DTM mode, if the control plane has transmitted LLC
frames through the dedicated channel or has transmitted the
DTM assignment, the user plane is informed too and it believes
the DL TBF establishment has started.
Measurement During the DL GRPS TBF establishment on CCCH/PCCCH, after
Point the user plane sends the request to the control plane, receives
the resource assignment message, successfully creates the DL
RLC instance and sends the Packet Polling Request message to
MS, this counter increments. The measurement point is A2, as
shown in Figure 5.

FIGURE 5 – NORM AL ESTABLISHMENT OF DL GPRS TBF ON CCCH/PCCCH

„ In the DTM mode, this counter increments when the user


plane receives the DTM sent message (the LLC frame has
been sent). The measurement point is A, as shown in Figure
6.

14 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Downlink Data TBF Measurement

„ In the DTM mode, this counter increments when the user


plane receives the DTM assignment message. The
measurement point is A, as shown in Figure 7.

FIGURE 6 – LLC FRAME TRANSMITS GTTP MESSAGE IN DTM MODE

FI G U R E 7 – DTM AS S I G N M E N T I N DTM MO D E

Unit Times

C901000012
Definition Number of GPRS DL TBF establishment execution failure on
CCCH/PCCCH due to polling failed
Description When MS is in the idle state, after BSC receives DL LLC frames
from SGSN, BSC should originate DL TBF establishment assigned
on CCCH/PCCCH. After receiving the resource assigned by the
control plane, the user plane sends the packet polling request
message through the assigned channel. When the MS responds
with the AB form of packet control ack message, the MS initial
timing advance is acquired then. If the MS does not respond, it
indicates the DL establishment has failed.
Measurement While waiting for MS responding with the AB form of packet
Point control ack message, if timeout occurs or messages informing
control block loss exceed the specified number, this counter
increments. The measurement point is A, as shown in Figure 8.

Confidential and Proprietary Information of ZTE CORPORATION 15


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 8 – MEASUREMENT POINT OF NUMBER OF TIMES FOR ESTABLISHING


GPRS DL TBF WITH POLLING FAILED ON CCCH/PCCCH

MS BSC user BSC control SGSN


plane plane

Packet Idle State


LLC Frame

Downlink Assign Request

Immediate Assignment /Packet Downlink Assignment

Resource Assign
Packet Polling Request

Packet Polling Request


Timeout
...
A

Unit Times

C901000013
Definition Number of GPRS DL TBF establishment execution success on
CCCH/PCCCH due to polling succeeded
Description „ When MS is in the idle state, after BSC receives DL LLC
frames from SGSN, BSC should originate DL TBF
establishment assigned on CCCH/PCCCH. After receiving the
resource assigned by the control plane, the user plane sends
the packet polling request message through the assigned
channel. When the MS responds with the AB form of packet
control ack message, the MS initial timing advance is
acquired then. If the BSC receives the packet control ack
message and sends the message of timing advance setting,
it indicates that the operation is successful.
„ In the DTM mode, if the user plane receives the DTM
assignment message from the control plane, the operation is
considered to be successful.
„ Besides, in the DTM mode, if the user plane receives the DTM
sent message from the control plane, to keep the
consistency of DL TBF establishment attempts and successful
establishments, the DL TBF establishment is also considered
to be successful.
Measurement When BSC receives the packet control ack message from MS
Point after sending the packet polling request message, or when in the
DTM mode, the user plane receives the DTM sent/assignment
message from the control plane, this counter increments. The
measurement points are A3 as shown in Figure 5, A as shown in
Figure 6, and A as shown in Figure 7.
Unit Times

16 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Downlink Data TBF Measurement

C901000014
Definition Number of GPRS DL TBF establishment success on CCCH/PCCCH
Description „ When MS is in the idle state, after BSC receives DL LLC
frames from SGSN, BSC should originate DL TBF
establishment assigned on CCCH/PCCCH. After receiving the
resource assigned by the control plane, the user plane sends
the packet polling request message through the assigned
channel. When the MS responds with the AB form of packet
control ack message, the MS initial timing advance is
acquired then. After receiving the packet control ack
message, BSC sends the message of timing advance setting.
If the assignment is on PCCCH, it indicates the DL TBF
establishment is successful and the DL data will be
transmitted soon; if the assignment is on CCCH, the data will
be transmitted after packet DL assignment message is sent
to MS.
„ In the DTM mode, if the user plane receives the DTM
assignment message from the control plane, the operation is
considered to be successful.
„ Besides, in the DTM mode, if the user plane receives the DTM
sent message from the control plane, to keep the
consistency of DL TBF establishment attempts and successful
establishments, the GPRS DL TBF establishment is also
considered to be successful.
Measurement „ If the assignment is on PCCCH, after the user plane sends
Point the packet polling request message and receives the packet
control ack message from MS, the counter increments.
„ If the assignment is on CCCH, after the user plane receives
the packet control ack message from MS and successfully
sends the DL assignment message, the counter increments.
„ In the DTM mode, when the user plane receives the DTM
sent/assignment message from the control plane, the
counter increments.
„ The measurement points are A3 (PCCCH) and A4 (CCCH), as
shown in Figure 5, A as shown in Figure 6, and A as shown in
Figure 7.
Unit Times

C901000015
Definition Number of GPRS DL TBF normal release
Description When the DL GPRS TBF sends the last data block, it sets FBI to 1
and sets the RRBP bit to let MS send the DL response message.
After BSC receives the last response message (FAI=1), it is
considered that the DL transmission is executed normally. In the

Confidential and Proprietary Information of ZTE CORPORATION 17


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

DTM mode, if the user plane receives the data sent message
from the control plane, to keep measurement consistency, it is
considered that the DL TBF is released normally.
Measurement After the DL GPRS TBF transmits the last data block (FBI=1) and
Point when BSC receives the last DL response message (FAI=1), this
counter increments. The measurement points are A, as shown in
Figure 9 and Figure 6.

FIGURE 9 – NORM AL RELEASE OF DL TBF

MS BSC

RLC Block
RLC Block (FBI=1)

Packet Downlink Ack

A T3193

Unit Times

C901000023
Definition Number of EGPRS DL TBF resumption in delay state
Description This counter counts the number of retransmissions after the DL
EGPRS TBF finishes LLC frame transmission and receives new
LLC frames.
Measurement After the DL EGPRS TBF transmits all LLC frames and before the
Point DL RLC block with FBI = 1 is transmitted, if the DL TBF receives
new LLC frames, this counter increments. The measurement
point is A, as shown in Figure 1.
Unit
Times

C901000027
Definition Number of EGPRS DL TBF establishment failure on PACCH due to
time out
Description In the UL transmission state, when SGSN DL LLC frame arrives,
the DL TBF transmission should be established. If there is no
reserved DL resource, the user plane will ask the control plane
to allocate resource. This counter counts the number of non-
responses from the control plane in this case.
Measurement When the BSC sends DL Assignment Request, the timer waiting
Point for response is triggered. The counter increments if the timer
expires. The measurement point is A, as shown in Figure 2.

18 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Downlink Data TBF Measurement

Unit Times

C901000028
Definition Number of EGPRS DL TBF establishment failure on PACCH due to
other reasons
Description This counter counts the number of TBF establishment failures
caused by other reasons than non-responses from the control
plane when PACCH of EGPRS TBF tries to establish DL TBF. The
other reasons here include failed transmission of assignment
messages and failed creation of DL RLC instances.
Measurement When PACCH fails to send the assignment messages or fails to
Point create DL RLC instances, the counter increments.
Unit Times

C901000031
Definition Number of EGPRS DL TBF establishment failure on CCCH/PCCCH
due to time out
Description When MS is in the idle state, after BSC receives DL LLC frames
from SGSN, BSC should originate DL TBF establishment assigned
on CCCH/PCCCH. The user plane asks the control plane for radio
resources. If the user plane fails to receive the resources within
the specified time or it receives the message of assignment
failure, it indicates that the DL TBF establishment fails.
Measurement During the DL EGPRS TBF establishment on CCCH/PCCCH, if
Point there is no radio resource assigned by the control plane within
the specified time, this counter increments. The measurement
points are A, as shown in Figure 3 and Figure 4.
Unit Times

C901000032
Definition Number of EGPRS DL TBF establishment failure on CCCH/PCCCH
due to other reasons
Description When MS is in the idle state, after BSC receives DL LLC frames
from SGSN, BSC should originate DL TBF establishment assigned
on CCCH/PCCCH. The user plane sends a DL establishment
request to the control plane. If it receives the instance release
message from the control plane or fails to create DL RLC
instance after receiving the resource assignment message, it
indicates that the DL TBF establishment fails.
Measurement During the DL EGRPS TBF establishment on CCCH/PCCCH, after
Point the user plane sends the request to the control plane, if it

Confidential and Proprietary Information of ZTE CORPORATION 19


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

receives the instance release message from the control plane or


fails to create DL RLC instance after receiving the resource
assignment message, this counter increments.
Unit Times

C901000033
Definition Number of EGPRS DL TBF establishment execution on
CCCH/PCCCH
Description When MS is in the idle state, after BSC receives DL LLC frames
from SGSN, BSC should originate DL TBF establishment assigned
on CCCH/PCCCH. After receiving the request from the user plane,
the control plane assigns the resource, sends the assignment
message on CCCH/PCCCH, and informs the user plane. The
initial timing advance is acquired then and the DL TBF
establishment starts.
In the DTM mode, if the control plane has transmitted LLC
frames through the dedicated channel or has transmitted the
DTM assignment, the user plane is informed too and it believes
the DL TBF establishment has started.
Measurement „ During the DL EGRPS TBF establishment on CCCH/PCCCH,
Point after the user plane sends the request to the control plane,
receives the resource assignment message, successfully
creates the DL RLC instance and sends the Packet Polling
Request message to MS, this counter increments. The
measurement point is A2, as shown in Figure 5.
„ In the DTM mode, this counter increments when the user
plane receives the DTM sent message (the LLC frame has
been sent). The measurement point is A, as shown in Figure
6.
„ In the DTM mode, this counter increments when the user
plane receives the DTM assignment message. The
measurement point is A, as shown in Figure 7.
Unit Times

C901000034
Definition Number of EGPRS DL TBF establishment execution failure on
CCCH/PCCCH due to polling failed
Description When MS is in the idle state, after BSC receives DL LLC frames
from SGSN, BSC should originate DL TBF establishment assigned
on CCCH/PCCCH. After receiving the resource assigned by the
control plane, the user plane sends the packet polling request
message through the assigned channel. When the MS responds
with the AB form of packet control ack message, the MS initial

20 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Downlink Data TBF Measurement

timing advance is acquired then. If the MS does not respond, it


indicates the DL establishment fails.
Measurement While waiting for MS responding with the AB form of packet
Point control ack message, if timeout occurs or messages informing
control block loss exceed the specified number, this counter
increments. The measurement point is A, as shown in Figure 8.
Unit Times

C901000035
Definition Number of EGPRS DL TBF establishment execution success on
CCCH/PCCCH due to polling succeeded
Description „ When MS is in the idle state, after BSC receives DL LLC
frames from SGSN, BSC should originate DL TBF
establishment assigned on CCCH/PCCCH. After receiving the
resource assigned by the control plane, the user plane sends
the packet polling request message through the assigned
channel. When the MS responds with the AB form of packet
control ack message, the MS initial timing advance is
acquired then. If the BSC receives the packet control ack
message and sends the message of timing advance setting,
it indicates that the operation is successful.
„ In the DTM mode, if the user plane receives the DTM
assignment message from the control plane, the operation is
considered to be successful.
„ Besides, in the DTM mode, if the user plane receives the DTM
sent message from the control plane, to keep the
consistency of DL TBF establishment attempts and successful
establishments, the DL TBF establishment is also considered
to be successful.
Measurement When BSC receives the packet control ack message from MS
Point after sending the packet polling request message, or when in the
DTM mode, the user plane receives the DTM sent/assignment
message from the control plane, this counter increments. The
measurement points are A3, as shown in Figure 5, A as shown in
Figure 6, and A as shown in Figure 7.
Unit Times

C901000036
Definition Number of EGPRS DL TBF establishment success on
CCCH/PCCCH
Description „ When MS is in the idle state, after BSC receives DL LLC
frames from SGSN, BSC should originate DL TBF
establishment assigned on CCCH/PCCCH. After receiving the
resource assigned by the control plane, the user plane sends

Confidential and Proprietary Information of ZTE CORPORATION 21


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

the packet polling request message through the assigned


channel. When the MS responds with the AB form of packet
control ack message, the MS initial timing advance is
acquired then. After receiving the packet control ack
message, BSC sends the message of timing advance setting.
If the assignment is on PCCCH, it indicates the DL TBF
establishment is successful and the DL data will be
transmitted soon; if the assignment is on CCCH, the data will
be transmitted after packet DL assignment message is sent
to MS.
„ In the DTM mode, if the user plane receives the DTM
assignment message from the control plane, the operation is
considered to be successful.
„ Besides, in the DTM mode, if the user plane receives the DTM
sent message from the control plane, to keep the
consistency of DL TBF establishment attempts and successful
establishments, the EGPRS DL TBF establishment is also
considered to be successful.
Measurement „ If the assignment is on PCCCH, after the user plane sends
Point the packet polling request message and receives the packet
control ack message from MS, the counter increments.
„ If the assignment is on CCCH, after the user plane receives
the packet control ack message from MS and successfully
sends the DL assignment message, the counter increments.
„ In the DTM mode, when the user plane receives the DTM
sent/assignment message from the control plane, the
counter increments.
„ The measurement points are A3 (PCCCH) and A4 (CCCH), as
shown in Figure 5, A as shown in Figure 6, and A as shown in
Figure 7.
Unit Times

C901000037
Definition Number of EGPRS DL TBF normal release
Description When the DL EGPRS TBF sends the last data block, it sets FBI to
1 and sets the RRBP bit to let MS send the DL response message.
After BSC receives the last response message (FAI=1), it is
considered that the DL transmission is executed normally. In the
DTM mode, if the user plane receives the data sent message
from the control plane, to keep measurement consistency, it is
considered that the DL TBF is released normally.
Measurement After the DL EGPRS TBF transmits the last data block (FBI=1)
Point and when BSC receives the last DL response message (FAI=1),
this counter increments. The measurement points are A, as
shown in Figure 9 and Figure 6.
Unit Times

22 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Downlink Data TBF Measurement

C901000045
Definition Time of GPRS DL TBF connection
Description This counter counts the cumulated overall DL connecting time of
GPRS TBF within a cell.
Measurement „ (1) When GPRS TBF RLC transmission starts, this counter
Point accumulates.
„ (2) When GPRS TBF RLC transmission is released normally
(in the acknowledged mode, BSC receives the response with
FAI=1; or in the non-acknowledged mode, BSC receives the
Packet Control Ack message), this counter accumulates.
„ (3) When GPRS TBF RLC transmission is released abnormally
(including N3105 overflow and T3191 timeout), this counter
accumulates.
„ (4) When the measurement value is acquired regularly, this
counter accumulates.
„ The measurement value is a cumulated overall measurement
value. After each accumulation, the measurement time point
is updated with the current time. For Measurement Point (1),
after each accumulation, the number of DL GPRS TBFs that
are being transmitted increments by 1; for Measurement
Point (2) and Measurement Point (3), after each
accumulation, the number of DL GPRS TBFs that are being
transmitted decreases by 1. The measurement method is
shown in Figure 10.

FIGURE 10 – MEASUREMENT OF CUMULATED OVERALL DL CONNECTING TIME

Unit Second

C901000046
Definition Time of EGPRS DL TBF connection
Description This counter counts the cumulated overall DL connecting time of
EGPRS TBF within a cell.

Confidential and Proprietary Information of ZTE CORPORATION 23


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement The measurement point and the formulas are as shown in Figure
Point 10. EGPRS TBF is the measurement prerequisite.
Unit Second

C901000047
Definition Time of DL signaling TBF connection
Description This counter counts the cumulated overall DL connecting time of
signaling TBF within a cell.
Measurement The measurement point and the formulas are as shown in Figure
Point 10. Signaling TBF is the measurement prerequisite.
Unit Second

C901000048
Definition Max number of GPRS DL TBF simultaneous establishment
Description The counter counts the maximum number of DL GPRS TBFs that
are established simultaneously within a cell.
Measurement „ When GPRS TBF RLC transmission starts, the GPRS TBFs in
Point the cell increments by 1 and compares with the saved
maximum value.
„ When the measurement value is acquired regularly, compare
the number of GPRS TBF in the cell with the saved maximum
value.
For the measurement of number of GPRS TBFs in a cell, refer to
Measurement Point of C901000045.
Unit Times

C901000050
Definition Max number of EGPRS DL TBF simultaneous establishment
Description The counter counts the maximum number of DL EGPRS TBFs
that are established simultaneously within a cell.
Measurement „ When EGPRS TBF RLC transmission starts, the EGPRS TBFs
Point in the cell increments by 1 and compares with the saved
maximum value.
„ When the measurement value is acquired regularly, compare
the number of EGPRS TBF in the cell with the saved
maximum value.
For the measurement of number of EGPRS TBFs in a cell, refer
to Measurement Point of C901000045.

24 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Downlink Data TBF Measurement

Unit Times

C901000052
Definition Number of GPRS DL signaling TBF normal release
Description When the DL GPRS signaling TBF sends the last data block, it
sets FBI to 1 and sets the RRBP bit to let MS send the DL
response message. After BSC receives the last response
message (FAI=1), it is considered that the DL transmission is
executed normally. In the DTM mode, if the user plane receives
the data sent message from the control plane, to keep
measurement consistency, it is considered that the DL TBF is
released normally.
Measurement After the DL GPRS signaling TBF transmits the last data block
Point (FBI=1) and when BSC receives the last DL response message
(FAI=1), this counter increments. The measurement points are
A, as shown in Figure 9 and Figure 6.
Unit Times

C901000058
Definition Number of EGPRS DL signaling TBF normal release
Description When the DL EGPRS signaling TBF sends the last data block, it
sets FBI to 1 and sets the RRBP bit to let MS send the DL
response message. After BSC receives the last response
message (FAI=1), it is considered that the DL transmission is
executed normally. In the DTM mode, if the user plane receives
the data sent message from the control plane, to keep
measurement consistency, it is considered that the DL EGPRS
TBF is released normally.
Measurement After the DL EGPRS signaling TBF transmits the last data block
Point (FBI=1) and when BSC receives the last DL response message
(FAI=1), this counter increments. The measurement points are
A, as shown in Figure 9 and Figure 6.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 25


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

26 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2

Uplink Data TBF


Measurement

This chapter contains detailed information (including counter


description, usage and measurement point) about counters
related to uplink data TBF measurement, which is for TBF
establishment and release of cells.

Overview
Uplink (UL) data TBF measurement mainly involves processes of
establishing TBF, keeping TBF and releasing TBF on cells.
The measurement takes cell as the statistics unit.

UL Data TBF Measurement Counter


Index
Table 6 lists counters related to UL data TBF measurement.

TABLE 6 – UL DAT A TBF M EASUREMENT COUNTERS

Counter ID What It Counts


Number of GPRS UL TBF resumption in extend uplink
C901010001
state
Number of GPRS UL TBF resource reassign in delay
C901010002
uplink state
Number of GPRS establishment failure on PACCH due
C901010006
to time out
Number of GPRS establishment failure on PACCH due
C901010007
to other reasons
Number of GPRS UL TBF establishment failure on
C901010010
CCCH/PCCCH due to competition solving failed

Confidential and Proprietary Information of ZTE CORPORATION 27


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter ID What It Counts


Number of GPRS UL TBF establishment failure on
C901010011
CCCH/PCCCH due to not receive resource request
Number of GPRS UL TBF establishment failure on
C901010012
CCCH/PCCCH due to other reasons
Number of GPRS UL TBF establishment success on
C901010013
CCCH/PCCCH
C901010014 Number of GPRS UL TBF normal release
Number of EGPRS UL TBF resumption in extend
C901010022
uplink state
Number of EGPRS UL TBF resource reassign in delay
C901010023
uplink state
Number of EGPRS establishment failure on PACCH
C901010027
due to time out
Number of EGPRS establishment failure on PACCH
C901010028
due to other reasons
Number of EGPRS UL TBF establishment failure on
C901010031
CCCH/PCCCH due to competition solving failed
Number of EGPRS UL TBF establishment failure on
C901010032
CCCH/PCCCH due to not receive resource request
Number of EGPRS UL TBF establishment failure on
C901010033
CCCH/PCCCH due to other reasons
Number of EGPRS UL TBF establishment success on
C901010034
CCCH/PCCCH
C901010035 Number of EGPRS UL TBF normal release
C901010043 Time of GPRS UL TBF connection
C901010044 Time of EGPRS UL TBF connection
C901010045 Time of UL signaling TBF connection
Max number of GPRS UL TBF simultaneous
C901010046
establishment
Max number of EGPRS UL TBF simultaneous
C901010048
establishment
C901010050 Number of GPRS UL signaling TBF normal release
C901010056 Number of EGPRS UL signaling TBF normal release

C901010001
Definition Number of GPRS UL TBF resumption in extend uplink state
Description MS notifies BSS whether extended GPRS UL TBF is supported by
reporting its radio access capability. If extended GPRS UL TBF is
supported, BSS will not stop allocating resources within a certain
period of time after receiving RLC block (CV=0) from MS. During

28 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - Uplink Data TBF Measurement

this period, if MS has new data to transmit, the data is


transmitted directly by the block allocated, and after BSS
receives a new block, TBF will be resumed to be in normal
transmission state. If MS has no new data to transmit, the
message Packet UL Dummy Control Block is transmitted by
the block allocated.
Usage This counter is used to record number of resumptions for GPRS
UL TBF in extended UL state.
Measurement This counter increments when a new data block is received in
Point GPRS extended UL state. The measurement point is A, as shown
in Figure 11.

FIGURE 11 – MEASUREMENT POINT ON RECEIVING NEW DAT A BLOCK IN


GPRS EXTENDED UL STATE

Unit Times

C901010002
Definition Number of GPRS UL TBF resource reassign in delay uplink state
Description If either MS or network does not support extended UL, after
receiving RLC block (CV = 0) from MS, network will enter in
delayed UL state, and meanwhile stop allocating blocks.
Usage This counter is used to record number of resource reassignment
for GPRS UL TBF in delayed UL state.
Measurement This counter increments when UPPB receives UL resource
Point reassign for GPRS UL TBF in delayed UL state, A, as shown in
Figure 12.

FIGURE 12 – MEASUREMENT POINT ON RECEIVING RESOURCE REASSIGNMENT


FOR GPRS UL TBF IN DELAYED UL STATE

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 29


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901010006
Definition Number of GPRS establishment failure on PACCH due to time out
Description During TBF transmission of an MS with downlink TBF, if MS has
UL data to transmit but no corresponding TBF is available, UL
TBF establishment request will be sent out by Packet Downlink
Ack. UPPB will request CMP for resources if it does not have UL
resource records, and meanwhile, UPPB starts the timer. The
request fails if the timer gets no response till timeout.
Usage This counter is used to record number of request failures caused
by timeout for establishing GPRS on PACCH.
Measurement The measurement point is A, as shown in Figure 13.
Point
FIGURE 13 – MEASUREMENT POINT ON NUMBER OF REQUEST FAILURES
CAUSED BY TIMEOUT FOR ESTABLISHING GPRS ON PACCH GPRS

Unit Times

C901010007
Definition Number of GPRS establishment failure on PACCH due to other
reasons
Description During TBF transmission of an MS with downlink TBF, if MS has
UL data to transmit but no corresponding TBF is available, UL
TBF establishment request will be sent out by Packet Downlink
Ack. Generally, network will assign resources to MS; However,
UL TBF establishment request fails if there is any condition
abnormal.
Usage This counter is used to record number of request failures caused
by other reasons for establishing GPRS on PACCH.
Measurement This counter increments when the request for establishing GPRS
Point on PACCH fails because of other reasons except timer is timeout.
Unit Times

C901010010
Definition Number of GPRS UL TBF establishment failure on CCCH/PCCCH
due to competition solving failed

30 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - Uplink Data TBF Measurement

Description When MS has new data to transmit but no corresponding


UL/downlink TBF is available, MS initiates UL TBF establishment
flow, depending on whether the cell configures PBCCH on
CCCH/PCCCH.
If two-step access is not compulsory at network side, in the case
of request for one-step access, MS sends RLC block with TLLI or
Packet Resource Request/ Additional MS Radio Access
Capabilities on the UL block allocated after receiving
assignment message from network so that solution by
competition can be completed. Meanwhile, network sends
Packet UL Ack with TLLI as well.
After sending out assignment message, if network does not
receive RLC block or Packet Resource Request/ Additional
MS Radio Access Capabilities from MS till timeout, solution
for one-step access by competition fails.
Usage This counter is used to record number of failed GPRS UL TBF
establishment on CCCH/PCCCH due to the failure of one-step
sccess competition solution.
Measurement The measurement point is A, as shown in Figure 14.
Point
FIGURE 14 – MEASUREMENT POINT ON NUMBER OF ESTABLISHMENT
FAILURES OF GPRS UL TBF CAUSED BY COMPETITION SOLUTION FAILURE

Unit Times

C901010011
Definition Number of GPRS UL TBF establishment failure on CCCH/PCCCH
due to not receive resource request
Description When MS has new data to transmit but no corresponding
UL/downlink TBF is available, MS initiates UL TBF establishment
flow, depending on whether the cell configures PBCCH on
CCCH/PCCCH.
If two-step access is compulsory at network side, in the case of
request for two-step access, network assigns to MS single block
resource, by which MS then reports Packet Resource Request.
After that, network assigns new resource for MS by Packet UL
Assignment according to MS’s radio access capability.

Confidential and Proprietary Information of ZTE CORPORATION 31


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

After assigning single block resource to MS, if network does not


receive Packet Resource Request from MS, the request to
establish GPRS UL TBF fails.
Usage This counter is used to record number of failed GPRS UL TBF
establishment on CCCH/PCCCH caused by not receiving resource
request.
Measurement The measurement point is A, as shown in Figure 15.
Point
FIGURE 15 – MEASUREMENT POINT ON NUMBER OF ESTABLISHMENT
FAILURES OF GPRS UL TBF CAUSED BY NOT RECEIVING RESOURCE
REQUEST

Unit Times

C901010012
Definition Number of GPRS UL TBF establishment failure on CCCH/PCCCH
due to other reasons
Description When MS has new data to transmit but no corresponding
UL/downlink TBF is available, MS initiates UL TBF establishment
flow, depending on whether the cell configures PBCCH on
CCCH/PCCCH.
If two-step access is not compulsory at network side, in the case
of request for one-step access, MS sends RLC block with TLLI or
Packet Resource Request/ Additional MS Radio Access
Capabilities on the UL block allocated after receiving
assignment message from network so that solution by
competion can be completed. Meanwhile, network sends Packet
UL Ack with TLLI as well.
If two-step access is compulsory at network side, in the case of
request for two-step access, network assigns to MS single block
resource, by which MS then reports Packet Resource Request.
After that, network assigns new resource for MS by Packet UL
Assignment according to MS’s wireless radio access capability.
Usage This counter is used to record number of failed GPRS UL TBF
establishment on CCCH/PCCCH caused by any other reasons.
Measurement This counter increments when GPRS UL TBF establishment fails
Point because of other reasons, except that one-step access
competition solution fails or two-step access does not receive
resource request.
Unit Times

32 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - Uplink Data TBF Measurement

C901010013
Definition Number of GPRS UL TBF establishment success on CCCH/PCCCH
Description When MS has new data to transmit but no corresponding
UL/downlink TBF is available, MS initiates UL TBF establishment
flow, depending on whether the cell configures PBCCH on
CCCH/PCCCH.
If two-step access is not compulsory at network side, in the case
of request for one-step access, MS sends RLC block with TLLI or
Packet Resource Request/ Additional MS Radio Access
Capabilities on the UL block allocated after receiving
assignment message from network so that solution by
competion can be completed. Meanwhile, network sends Packet
UL Ack with TLLI as well.
If two-step access is compulsory at network side, in the case of
request for two-step access, network assigns to MS single block
resource, by which MS then reports Packet Resource Request.
After that, network assigns new resource for MS by Packet UL
Assignment according to MS’s wireless radio access capability.
Usage This counter is used to record number of successful GPRS UL
TBF establishment on CCCH/PCCCH.
Measurement This counter increments when GPRS UL TBF establishment on
Point CCCH/PCCCH succeeds in the cases of both one-step access and
two-step access. The measurement points are A, as shown in
Figure 16 and Figure 17.

FIGURE 16 – MEASUREMENT POINT ON NUMBER OF SUCCESSFUL GPRS UL


TBF ESTABLISHMENT ON CCCH/PCCCH (I)

Confidential and Proprietary Information of ZTE CORPORATION 33


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 17 – MEASUREMENT POINT ON NUMBER OF SUCCESSFUL GPRS UL


TBF ESTABLISHMENT ON CCCH/PCCCH (II)

Unit Times

C901010014
Definition Number of GPRS UL TBF normal release
Description If having received all data blocks, BSS sends Packet UL Ack
with FAI to MS and sets RRBP when receiving RLC block (CV =
0). MS then reports Packet Control Ack on corresponding UL
block, notifying BSS to release TBF normally.
Usage This counter is used to record number of normal GPRS UL TBF
releases.
Measurement The measurement point is A, as shown in Figure 18.
Point
FIGURE 18 – MEASUREMENT POINT ON NUMBER OF NORM AL GPRS UL TBF
RELEASE

Unit Times

C901010022
Definition Number of EGPRS UL TBF resumption in extend uplink state
Description MS notifies BSS whether extended GPRS UL TBF is supported by
reporting its radio access capability. If extended GPRS UL TBF is
supported, BSS will not stop allocating resources within a certain
period of time after receiving RLC block (CV = 0) from MS.
During this period, if MS has new data to transmit, the data is

34 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - Uplink Data TBF Measurement

transmitted directly by the block allocated, and after the


network receives a new block, TBF will be resumed to be in
normal transmission state. If MS has no new data to transmit,
the message Packet UL Dummy Control Block is transmitted
by the block allocated.
Usage This counter is used to record number of resumptions for EGPRS
UL TBF in extended UL state.
Measurement The measurement point is A, as shown in Figure 19.
Point
FIGURE 19 – MEASUREMENT POINT ON NUMBER OF RESUMPTIONS FOR
EGPRS UL TBF IN EXTENDED UL STATE

Unit Times

C901010023
Definition Number of EGPRS UL TBF resource reassign in delay uplink state
Description If either MS or BSS does not support extended UL, after
receiving RLC block (CV = 0) from MS, BSS will enter in delayed
UL state, and meanwhile stop allocating blocks.
Usage This counter is used to record number of resource reassignments
for EGPRS UL TBF in delayed UL state.
Measurement The measurement point is A, as shown in Figure 20.
Point
FIGURE 20 – MEASUREMENT POINT ON NUMBER OF RESOURCE
REASSIGNMENTS FOR EGPRS UL TBF IN DELAYED UL STATE

Unit Times

C901010027
Definition Number of EGPRS establishment failure on PACCH due to time
out

Confidential and Proprietary Information of ZTE CORPORATION 35


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description During TBF transmission of an MS with downlink TBF, if MS has


UL data to transmit but no corresponding UL TBF is available, UL
TBF establishment request will be sent out by Packet Downlink
Ack. UPPB will request CMP for resources if having no UL
resource records, and meanwhile, UPPB starts the timer. The
request fails if the timer gets no response till timeout.
Usage This counter is used to record number of request failures caused
by timeout for establishing EGPRS on PACCH.
Measurement The measurement point is A, as shown in Figure 21.
Point
FIGURE 21 – MEASUREMENT POINT ON NUMBER OF REQUEST FAILURES
CAUSED BY TIM EOUT FOR ESTABLISHING EGPRS ON ON P ACCH

Unit Times

C901010028
Definition Number of EGPRS establishment failure on PACCH due to other
reasons
Description During TBF transmission of an MS with downlink TBF, if MS has
UL data to transmit but no corresponding UL TBF is available, UL
TBF establishment request will be sent out by Packet Downlink
Ack. Generally, network will assign resources to MS; However,
UL TBF establishment request fails if there is any condition
abnormal.
Usage This counter is used to record number of request failures caused
by other reasons for establishing GPRS on PACCH.
Measurement This counter increments when request for establishing EGPRS on
Point PACCH fails because of other reasons except timer is timeout.
Unit Times

C901010031
Definition Number of EGPRS UL TBF establishment failure on CCCH/PCCCH
due to competition solving failed
Description When MS has new data to transmit but no corresponding
UL/downlink TBF is available, MS initiates UL TBF establishment
flow, depending on whether the cell configures PBCCH on
CCCH/PCCCH.

36 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - Uplink Data TBF Measurement

If two-step access is not compulsory at network side, in the case


of request for one-step access, MS sends RLC block with TLLI or
Packet Resource Request/ Additional MS Radio Access
Capabilities on the UL block allocated after receiving
assignment message from network so that solution by
competion can be completed. Meanwhile, network sends Packet
UL Ack with TLLI as well.
After sending out assignment message, if network does not
receive RLC block or Packet Resource Request/ Additional
MS Radio Access Capabilities from MS till timer is timeout,
solution for one-step access by competition fails.
Usage This counter is used to record number of failed EGPRS UL TBF
establishment on CCCH/PCCCH caused by competition solving
failed.
Measurement The measurement point is A, as shown in Figure 22.
Point
FIGURE 22 – MEASUREMENT POINT ON NUMBER OF ESTABLISHMENT
FAILURES OF EGPRS UL TBF CAUSED BY COMPETITION SOLVING FAILED

Unit Times

C901010032
Definition Number of EGPRS UL TBF establishment failure on CCCH/PCCCH
due to not receive resource request
Description When MS has new data to transmit but no corresponding
UL/downlink TBF is available, MS initiates UL TBF establishment
flow, depending on whether the cell configures PBCCH on
CCCH/PCCCH.
If two-step access is compulsory at network side, in the case of
request for two-step access, network assigns to MS single block
resource, by which MS then reports Packet Resource Request.
After that, network assigns new resource for MS by Packet UL
Assignment according to MS’s radio access capability.
After assigning single block resource to MS, if network does not
receive Packet Resource Request from MS, the request to
establish GPRS UL TBF fails.
Usage This counter is used to record number of failed EGPRS UL TBF
establishment on CCCH/PCCCH caused by not receiving resource
request.

Confidential and Proprietary Information of ZTE CORPORATION 37


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement The measurement point is A, as shown in Figure 23.


Point
FIGURE 23 – MEASUREMENT POINT ON NUMBER OF ESTABLISHMENT
FAILURES OF EGPRS UL TBF CAUSED BY NOT RECEIVING RESOURCE
REQUEST

MS BSS
Channel Request/Packet
Channel Request
Immediate Assignment/Packet
Uplink Assignment No Packet Resource
Request is received till
timer is timeout
A

Unit Times

C901010033
Definition Number of EGPRS UL TBF establishment failure on CCCH/PCCCH
due to other reasons
Description When MS has new data to transmit but no corresponding
UL/downlink TBF is available, MS initiates UL TBF establishment
flow, depending on whether the cell configures PBCCH on
CCCH/PCCCH.
If two-step access is not compulsory at network side, in the case
of request for one-step access, MS sends RLC block with TLLI or
Packet Resource Request/ Additional MS Radio Access
Capabilities on the UL block allocated after receiving
assignment message from network so that solution by
competition can be completed. Meanwhile, network sends
Packet UL Ack with TLLI as well.
If two-step access is compulsory at network side, in the case of
request for two-step access, network assigns to MS single block
resource, by which MS then reports Packet Resource Request.
After that, network assigns new resource for MS by Packet UL
Assignment according to MS’s wireless radio access capability.
Usage This counter is used to record number of failed EGPRS UL TBF
establishment on CCCH/PCCCH caused by any other reasons.
Measurement This counter increments when EGPRS UL TBF establishment fails
Point because of other reasons except that one-step access
competition solution fails or two-step access does not receive
resource request.
Unit Times

C901010034
Definition

38 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - Uplink Data TBF Measurement

Number of EGPRS UL TBF establishment success on


CCCH/PCCCH
Description When MS has new data to transmit but no corresponding
UL/downlink TBF is available, MS initiates UL TBF establishment
flow, depending on whether the cell configures PBCCH on
CCCH/PCCCH.
If two-step access is not compulsory at network side, in the case
of request for one-step access, MS sends RLC block with TLLI or
Packet Resource Request/ Additional MS Radio Access
Capabilities on the UL block allocated after receiving
assignment message from network so that solution by
competion can be completed. Meanwhile, network sends Packet
UL Ack with TLLI as well.
If two-step access is compulsory at network side, in the case of
request for two-step access, network assigns to MS single block
resource, by which MS then reports Packet Resource Request.
After that, network assigns new resource for MS by Packet UL
Assignment according to MS’s wireless radio access capability.
Usage This counter is used to record number of successful EGPRS UL
TBF establishment on CCCH/PCCCH.
Measurement This counter increments when EGPRS UL TBF establishment on
Point CCCH/PCCCH succeeds in the cases of both one-step access and
two-step access. The measurement points are A, as shown in
Figure 24 and Figure 25.

FIGURE 24 – MEASUREMENT POINT ON NUMBER OF SUCCESSFUL EGPRS UL


TBF ESTABLISHMENT ON CCCH/PCCCH (I)

FIGURE 25 – MEASUREMENT POINT ON NUMBER OF SUCCESSFUL EGPRS UL


TBF ESTABLISHMENT ON CCCH/PCCCH (II)

Confidential and Proprietary Information of ZTE CORPORATION 39


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Unit Times

C901010035
Definition Number of EGPRS UL TBF normal release
Description If having received all data blocks, BSS sends Packet UL Ack
with FAI to MS and sets RRBP when receiving RLC block (CV =
0). MS then reports Packet Control Ack on corresponding UL
block, notifying BSS to release TBF normally.
Usage This counter is used to record number of normal EGPRS UL TBF
releases.
Measurement The measurement point is A, as shown in Figure 26.
Point
FIGURE 26 – MEASUREMENT POINT ON NUMBER OF NORM AL EGPRS UL TBF
RELEASE

Unit Times

C901010043
Definition Time of GPRS UL TBF connection
Description MS establishes two types of TBF for different purposes. They are
signaling TBF and data TBF.
Usage This counter is used to find out cumulated overall UL connecting
time of GPRS TBF.
Measurement The counter starts to accumulate when UPPB receives the UL
Point GPRS TBF establishment indication, and stops when UL GPRS
TBF on UPPB ends normally.
Unit Second

C901010044
Definition Time of EGPRS UL TBF connection
Description MS establishes two types of TBF for different purposes. They are
signaling TBF and data TBF.

40 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - Uplink Data TBF Measurement

Usage This counter is used to find out cumulated overall UL connecting


time of EGPRS TBF.
Measurement The counter starts to accumulate when UPPB receives the UL
Point EGPRS TBF establishment indication, and stops when UL EGPRS
TBF on UPPB ends normally.
Unit Second

C901010045
Definition Time of UL signaling TBF connection
Description MS establishes two types of TBF for different purposes. They are
signaling TBF and data TBF.
Usage This counter is used to find out cumulated overall UL connecting
time of signaling TBF.
Measurement The counter starts to accumulate when UPPB receives the UL
Point signaling TBF establishment indication, and stops when UL
signaling TBF on UPPB ends normally.
Unit Second

C901010046
Definition Max number of GPRS UL TBF simultaneous establishment
Description During the measurement period, there might be several TBFs
existing simultaneously. This counter is used to find out the
maximum number of UL GPRS TBF established simultaneously
within the measurement period.
Usage This counter is used to find out the maximum number of UL
GPRS TBF established simultaneously within the measurement
period.
Measurement This counter increments when UPPB receives UL GPRS TBF
Point establishment indication, and decrements when the UL GPRS
TBF releases.
Unit Times

C901010048
Definition Max number of EGPRS UL TBF simultaneous establishment
Description During the measurement period, there might be several TBFs
existing simultaneously. This counter is used to find out the
maximum number of UL EGPRS TBF established simultaneously
within the measurement period
Usage

Confidential and Proprietary Information of ZTE CORPORATION 41


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This counter is used to find out the maximum number of UL


EGPRS TBF established simultaneously within the measurement
period.
Measurement This counter increments when UPPB receives UL EGPRS TBF
Point establishment indication, and decrements when the UL EGPRS
TBF releases.
Unit Times

C901010050
Definition Number of GPRS UL signaling TBF normal release
Description If having received all data blocks, BSS sends Packet UL Ack
with FAI to MS and sets RRBP when receiving RLC block (CV =
0). MS then reports Packet Control Ack on corresponding UL
block, notifying BSS to release TBF normally.
Usage This counter is used to record number of normal GPRS signaling
UL TBF releases.
Measurement The measurement point is A, as shown in Figure 27.
Point
FIGURE 27 – MEASUREMENT POINT ON NUMBER OF NORM AL GPRS
SIGNALING UL TBF RELEASE

Unit Times

C901010056
Definition Number of EGPRS UL signaling TBF normal release
Description If having received all data blocks, BSS sends Packet UL Ack
with FAI to MS and sets RRBP when receiving RLC block (CV =
0). MS then reports Packet Control Ack on corresponding UL
block, notifying BSS to release TBF normally.
Usage This counter is used to record number of normal EGPRS
signaling UL TBF releases.
Measurement The measurement point is A, as shown in Figure 28.
Point

42 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - Uplink Data TBF Measurement

FIGURE 28 – MEASUREMENT POINT ON NUMBER OF NORM AL GPRS


SIGNALING UL TBF RELEASE

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 43


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

44 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3

Data Flow Measurement

This chapter gives detailed information about the data flow


measurement on the PS user plane.

Overview
Data flow measurement focuses on the flow related information,
including the LLC frames, RLC blocks and TBF connecting time.
The measurement takes cell as the statistics unit.

Data Flow Measurement Counter


Index
Table 7 lists counters related to data flow measurement.

TABLE 7 - DATA FLOW MEASUREMENT COUNTERS

Counter ID What It Counts


C901020001 Number of Kbytes of IP packet sent to BIPB
C901020002 Number of packets sent to BIPB
C901020003 Number of Kbytes of IP packet received from BIPB
C901020004 Number of packets received from BIPB
C901020005 Number of Kbytes of IP packet sent to GIPB
C901020006 Number of packets sent to GIPB
C901020007 Number of Kbytes of IP packet received from GIPB
C901020008 Number of packets received from GIPB
C901020009 Number of Kbytes carried by EGPRS DL LLC frame
C901020014 Number of Kbytes carried by DL signaling LLC frame
C901020019 Number of Kbytes carried by UL LLC frame

Confidential and Proprietary Information of ZTE CORPORATION 45


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter ID What It Counts


C901020020 Number of UL LLC frames
C901020021 Number of Bytes of GPRS DL TBF LLC frame
C901020022 Number of Bytes of EGPRS DL TBF LLC frame
C901020023 Number of Bytes of DL signaling TBF LLC frame
C901020024 Number of Bytes of UL GPRS TBF LLC frame
C901020025 Number of Bytes of EGPRS UL TBF LLC frame
C901020026 Number of Bytes of UL signaling TBF LLC frame
C901020031 Number of GPRS UL data TBF completion
C901020034 Number of GPRS DL data TBF completion
C901020041 Number of EGPRS UL data TBF completion
C901020044 Number of EGPRS DL data TBF completion
C901020050 Number of Kbytes carried by GPRS DL LLC frame

C901020001
Definition Number of Kbytes of IP packet sent to BIPB
Description DSP on the DL UPPB board encodes RLC/MAC blocks to PCU
frames without sync headers and sends the frames to BIPB
through IP packets. BIPB adds them with sync headers and
sends them to BTS. After the UL BIPB receives the PCU frames
with sync headers (bearing RLC/MAC blocks) from BTS, it
removes the headers and sends them to UPPB through IP packet.
Usage The counter counts the size of IP packets sent to BIPB. The
measurement unit is Byte.
Measurement The measurement point is A, as shown in Figure 29.
Point
FIGURE 29 - MEASUREMENT POINT OF SIZE OF IP P ACKETS SENT TO BIPB

Unit Byte

46 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - Data Flow Measurement

C901020002
Definition Number of packets sent to BIPB
Description DSP on the DL UPPB board encodes RLC/MAC blocks to PCU
frames without sync headers and sends the frames to BIPB
through IP packets. BIPB adds them with sync headers and
sends them to BTS. After the UL BIPB receives the PCU frames
with sync headers (bearing RLC/MAC blocks) from BTS, it
removes the headers and sends them to UPPB through IP packet.
Usage The counter counts the number of IP packets sent to BIPB.
Measurement The measurement point is A, as shown in Figure 30.
Point
FIGURE 30 - MEASUREMENT POINT OF NUMBER OF IP P ACKETS SENT TO
BIPB

Unit Times

C901020003
Definition Number of Kbytes of IP packet received from BIPB
Description DSP on the DL UPPB board encodes RLC/MAC blocks to PCU
frames without sync headers and sends the frames to BIPB
through IP packets. BIPB adds them with sync headers and
sends them to BTS. After the UL BIPB receives the PCU frames
with sync headers (bearing RLC/MAC blocks) from BTS, it
removes the headers and sends them to UPPB through IP packet.
Usage The counter counts the size of IP packets received from BIPB.
The measurement unit is Byte.
Measurement The measurement point is A, as shown in Figure 31.
Point

Confidential and Proprietary Information of ZTE CORPORATION 47


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 31 - MEASUREMENT POINT OF SIZE OF IP P ACKETS RECEIVED FROM


BIPB

Unit Byte

C901020004
Definition Number of packets received from BIPB
Description DSP on the DL UPPB board encodes RLC/MAC blocks to PCU
frames without sync headers and sends the frames to BIPB
through IP packets. BIPB adds them with sync headers and
sends them to BTS. After the UL BIPB receives the PCU frames
with sync headers (bearing RLC/MAC blocks) from BTS, it
removes the headers and sends them to UPPB through IP packet.
Usage The counter counts the number of packets received from BIPB.
Measurement The measurement point is A, as shown in Figure 32.
Point
FIGURE 32 - MEASUREMENT POINT OF NUMBER OF IP P ACKETS RECEIVED
FROM BIPB

Unit Times

C901020005
Definition Number of Kbytes of IP packet sent to GIPB
Description The DL GIPB sends DL UnitData to UPPB through IP packets.
After caching DL UnitData, UPPB divides it into RLC blocks and
sends them to BTS through PCU frames. The UL UPPB decodes
the received RLC blocks, composes UL UnitData, and sends it to
GIPB through IP packet.
Usage The counter counts the size of IP packets sent to GIPB. The
measurement unit is Byte.

48 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - Data Flow Measurement

Measurement The measurement point is A, as shown in Figure 33.


Point
FIGURE 33- MEASUREMENT POINT OF SIZE OF IP P ACKETS SENT TO GIPB

Unit Byte

C901020006
Definition Number of packets sent to GIPB
Description The DL GIPB sends DL UnitData to UPPB through IP packets.
After caching DL UnitData, UPPB divides it into RLC blocks and
sends them to BTS through PCU frames. The UL UPPB decodes
the received RLC blocks, composes UL UnitData, and sends it to
GIPB through IP packet.
Usage The counter counts the number of IP packets sent to GIPB.
Measurement The measurement point is A, as shown in Figure 34.
Point
FIGURE 34 - MEASUREMENT POINT OF NUMBER OF IP P ACKETS SENT TO
GIPB

Unit Times

C901020007
Definition Number of Kbytes of IP packet received from GIPB
Description The DL GIPB sends DL UnitData to UPPB through IP packets.
After caching DL UnitData, UPPB divides it into RLC blocks and
sends them to BTS through PCU frames. The UL UPPB decodes
the received RLC blocks, composes UL UnitData, and sends it to
GIPB through IP packet.

Confidential and Proprietary Information of ZTE CORPORATION 49


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Usage The counter counts the size of IP packets received from GIPB.
The measurement unit is Byte.
Measurement The measurement point is A, as shown in Figure 35.
Point
FIGURE 35 - MEASUREMENT POINT OF SIZE OF IP P ACKETS RECEIVED FROM
GIPB

Unit Byte

C901020008
Definition Number of packets received from GIPB
Description The DL GIPB sends DL UnitData to UPPB through IP packets.
After caching DL UnitData, UPPB divides it into RLC blocks and
sends them to BTS through PCU frames. The UL UPPB decodes
the received RLC blocks, composes UL UnitData, and sends it to
GIPB through IP packet.
Usage The counter counts the number of IP packets received from GIPB.
Measurement The measurement point is A, as shown in Figure 36.
Point
FIGURE 36 - MEASUREMENT POINT OF NUMBER OF IP P ACKETS RECEIVED
FROM GIPB

Unit Times

C901020009
Definition Number of Kbytes carried by EGPRS DL LLC frame
Description The DL GIPB sends DL UnitData to UPPB through IP packets.
tQoSProfile Tbit in DL UnitData identifies whether data or

50 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - Data Flow Measurement

signaling is transmitted. UPPB applies to CMP to establish DL TBF


(radio access capacity to carry MS) and according to the CMP
command, establishes EGPRS/GPRS TBF.
Usage The counter counts the number of Kbytes carried by DL EGPRS
LLC frame.
Measurement The measurement point is A, as shown in Figure 37.
Point
FIGURE 37 - MEASUREMENT POINT OF NUMBER OF KBYTES CARRIED BY DL
EGPRS LLC FRAME

Unit Byte

C901020014
Definition Number of Kbytes carried by DL signaling LLC frame
Description The DL GIPB sends DL UnitData to UPPB through IP packets.
tQoSProfile Tbit in DL UnitData identifies whether data or
signaling is transmitted. UPPB applies to the control plane to
establish DL TBF (radio access capacity to carry MS) and
according to the command from the control plane, establishes
EGPRS/GPRS TBF.
Usage The counter counts the number of Kbytes carried by DL signaling
LLC frame.
Measurement The measurement point is A, as shown in Figure 38.
Point
FIGURE 38 - MEASUREMENT POINT OF NUMBER OF KBYTES CARRIED BY DL
SIGNALING LLC FRAME

Unit Byte

Confidential and Proprietary Information of ZTE CORPORATION 51


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901020019
Definition Number of Kbytes carried by UL LLC frame
Description The UL UPPB sends the composed LLC frames to GIPB through
IP packet.
Usage The counter counts the number of Kbytes carried by UL LLC
frame.
Measurement The measurement point is A, as shown in Figure 39.
Point
FIGURE 39 - MEASUREMENT POINT OF NUMBER OF KBYTES CARRIED BY UL
LLC FRAME

Unit Byte

C901020020
Definition Number of UL LLC frames
Description The UL UPPB sends the composed LLC frames to GIPB through
IP packet.
Usage The counter counts the number of UL LLC frames.
Measurement The measurement point is A, as shown in Figure 40.
Point
FIGURE 40 - MEASUREMENT POINT OF NUMBER OF UL LLC FRAMES

Unit Times

52 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - Data Flow Measurement

C901020021
Definition Number of Bytes of GPRS DL TBF LLC frame
Description UPPB divides the DL LLC frame into RLC blocks and sends them
to MS. After correctly receiving those RLC blocks, MS will
recompose the LLC frame. UPPB acquires the information about
MS reception by setting RRBP to let MS report Packet DL Ack.
Usage The counter counts the number of bytes of DL GPRS TBF LLC
frame.
Measurement The measurement point is A, as shown in Figure 41.
Point
FIGURE 41 - MEASUREMENT POINT OF NUMBER OF BYTES OF DL GPRS TBF
LLC FRAME

Unit Byte

C901020022
Definition Number of Bytes of EGPRS DL TBF LLC frame
Description UPPB divides the DL LLC frame into RLC blocks and sends them
to MS. After correctly receiving those RLC blocks, MS will
recompose the LLC frame. UPPB acquires the information about
MS reception by setting RRBP to let MS report EGPRS Packet DL
Ack.
Usage The counter counts the number of bytes of DL EGPRS TBF LLC
frame.
Measurement The measurement point is A, as shown in Figure 42.
Point

Confidential and Proprietary Information of ZTE CORPORATION 53


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 42 - MEASUREMENT POINT OF NUMBER OF BYTES OF DL EGPRS


TBF LLC FRAME

Unit Byte

C901020023
Definition Number of Bytes of DL signaling TBF LLC frame
Description UPPB divides the DL LLC frame into RLC blocks and sends them
to MS. After correctly receiving those RLC blocks, MS will
recompose the LLC frame. UPPB acquires the information about
MS reception by setting RRBP to let MS report EGPRS Packet DL
Ack.
Usage The counter counts the number of bytes of DL signaling TBF LLC
frame.
Measurement The measurement point is A, as shown in Figure 43.
Point
FIGURE 43 - MEASUREMENT POINT OF NUMBER OF BYTES OF DL SIGNALING
TBF LLC FRAME

Unit Byte

C901020024
Definition Number of Bytes of UL GPRS TBF LLC frame
Description After receiving the RLC blocks reported by MS, UPPB composes
them into the LLC frame and sends it to SGSN.

54 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - Data Flow Measurement

Usage The counter counts the number of bytes of UL GPRS TBF LLC
frame.
Measurement The measurement point is A, as shown in Figure 44.
Point
FIGURE 44 - MEASUREMENT POINT OF NUMBER OF BYTES OF UL GPRS TBF
LLC FRAME

Unit Byte

C901020025
Definition Number of Bytes of EGPRS UL TBF LLC frame
Description After receiving the RLC blocks reported by MS, UPPB composes
them into the LLC frame and sends it to SGSN.
Usage The counter counts the number of bytes of UL EGPRS TBF LLC
frame.
Measurement The measurement point is A, as shown in Figure 45.
Point
FIGURE 45 - MEASUREMENT POINT OF NUMBER OF BYTES OF UL EGPRS
TBF LLC FRAME

Unit Byte

C901020026
Definition Number of Bytes of UL signaling TBF LLC frame
Description After receiving the RLC blocks reported by MS, UPPB composes
them into the LLC frame and sends it to SGSN.
Usage The counter counts the number of bytes of UL signaling TBF LLC
frame.
Measurement The measurement point is A, as shown in Figure 46.
Point

Confidential and Proprietary Information of ZTE CORPORATION 55


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 46 - MEASUREMENT POINT OF NUMBER OF BYTES OF UL SIGNALING


TBF LLC FRAME

Unit Byte

C901020031
Definition Number of GPRS UL data TBF completion
Description After the network side receives the data blocks (CV=0) from MS
and if all the other blocks have been received successfully, then
it will send the Packet UL Ack message (FAI=1) to MS. By this
time, the UL data transmission is completed.
Usage The counter counts the number of completion of GPRS UL data
TBF.
Measurement The measurement point is A, as shown in Figure 47.
Point
FIGURE 47 - MEASUREMENT POINT OF TOTAL NUMBER OF COMPLETION OF
GPRS UL DATA TBF

Unit Times

C901020034
Definition Number of GPRS DL data TBF completion
Description After MS receives the FBI-set data blocks (RRBP is set at the
network side) from the network side and if all the other blocks
have been received successfully, then it will send the Packet DL
Ack/EGPRS Packet DL Ack message (FAI=1) to the network side.
Usage The counter counts the number of completion of GPRS DL data
TBF.
Measurement The measurement point is A, as shown in Figure 48.
Point

56 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - Data Flow Measurement

FIGURE 48 - MEASUREMENT POINT OF TOTAL NUMBER OF COMPLETION OF


GPRS DL DATA TBF

Unit Times

C901020041
Definition Number of EGPRS UL data TBF completion
Description After the network side receives the data blocks (CV=0) from MS
and if all the other blocks have been received successfully, then
it will send the Packet UL Ack message (FAI=1) to MS. By this
time, the UL data transmission is completed.
Usage The counter counts the number of completion of EGPRS UL data
TBF.
Measurement The measurement point is A, as shown in Figure 49.
Point
FIGURE 49 - MEASUREMENT POINT OF TOTAL NUMBER OF COMPLETION OF
EGPRS UL DATA TBF

Unit Times

C901020044
Definition Number of EGPRS DL data TBF completion
Description After MS receives the FBI-set data blocks (RRBP is set at the
network side) from the network side and if all the other blocks
have been received successfully, then it will send the Packet DL
Ack/EGPRS Packet DL Ack message (FAI=1) to the network side.
Usage The counter counts the number of completion of EGPRS DL data
TBF.

Confidential and Proprietary Information of ZTE CORPORATION 57


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement The measurement point is A, as shown in Figure 50.


Point
FIGURE 50 - MEASUREMENT POINT OF TOTAL NUMBER OF COMPLETION OF
EGPRS DL DATA TBF

Unit Times

C901020050
Definition Number of Kbytes carried by GPRS DL LLC frame
Description The DL GIPB sends DL UnitData to UPPB through IP packets.
tQoSProfile Tbit in DL UnitData identifies whether data or
signaling is transmitted. UPPB applies to CMP to establish DL TBF
(radio access capacity to carry MS) and according to the CMP
command, establishes EGPRS/GPRS TBF.
Usage The counter counts the number of Kbytes carried by DL GPRS
LLC frame.
Measurement The measurement point is A, as shown in Figure 51.
Point
FIGURE 51 - MEASUREMENT POINT OF NUMBER OF KBYTES CARRIED BY DL
GPRS LLC FRAME

Unit Byte

58 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4

Uplink/Downlink RLC
Statistic Measurement

This chapter contains detailed information about counters


related to Uplink (UL)/Downlink (DL) RLC statistics counters.

Overview
RLC blocks are classified into control block and data block based
on the content. Data block includes RLC block waiting to be
acknowledged (Pending block), retransmitted block (NACK
block), and first-transmitted block (new blocks excluding
retransmitted RLC block and pending RLC blocks).
RLC coding scheme includes CS1 ~ CS4 and MCS1 ~ MCS9.
Coding scheme is set at background and can be adjusted by BSC
according to the link quality.
UL/DL RLC statistics is used to find out the number of RLC blocks
with different coding schemes received and sent by BSC as well
as coding scheme adjustment times during transmission process.
The measurement takes cell as the statistics unit.
Figure 52 shows the measurement point of DL pending RLC
block.

FIGURE 52 – MEASUREMENT POINT OF DL PENDING RLC BLOCK

Figure 53 shows the measurement point of DL retransmitted RLC


block.

Confidential and Proprietary Information of ZTE CORPORATION 59


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 53 – MEASUREMENT POINT OF DL RETRANSMITTED RLC BLOCK

Figure 54 shows the measurement point of DL first-transmitted


RLC block.

FIGURE 54 – MEASUREMENT POINT OF DL FIRST-TRANSMITTED RLC BLOCK

Figure 55 shows the measurement point of UL pending RLC


block.

FIGURE 55 – MEASUREMENT POINT OF UL PENDING RLC BLOCK

Figure 56 shows the measurement point of UL retransmitted RLC


block.

FIGURE 56 – MEASUREMENT POINT OF UL RETRANSMITTED RLC BLOCK

Figure 57 shows the measurement point of UL first-transmitted


RLC block.

60 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Uplink/Downlink RLC Statistic Measurement

FIGURE 57 – MEASUREMENT POINT OF UL FIRST-TRANSMITTED RLC BLOCK

Uplink/Downlink RLC Statistic


Measurement Counter Index
Table 8 lists counters related to uplink/downlink RLC statistic
measurement.

TABLE 8 – UL/DL RLC STATISTIC MEASUREMENT COUNTERS

Counter ID What It Counts


C901030041 Bytes of GPRS DL RLC lost on PDTCH
C901030042 Bytes of EGPRS DL RLC lost on PDTCH
C901030083 Number of UL RLC Blocks lost
C901030084 Bytes of GPRS UL RLC lost on PDTCH
C901030085 Bytes of EGPRS UL RLC lost on PDTCH
Number of standstill of GPRS UL TBF receiving
C901030086
window
Number of standstill of EGPRS UL TBF receiving
C901030087
window
Number of standstill of GPRS DL TBF sending
C901030088
window
Number of standstill of EGPRS DL TBF sending
C901030089
window
C901030090 Number of increment of DL coding mode
C901030091 Number of decrement of DL coding mode
C901030092 Number of increment of UL coding mode
C901030093 Number of decrement of UL coding mode
C901030094 Number of conversion from GMSK to 8PSK
C901030095 Number of conversion from 8PSK to GMSK

C901030041
Definition Bytes of GPRS DL RLC lost on PDTCH
Description This counter is not used for the time being.

Confidential and Proprietary Information of ZTE CORPORATION 61


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901030042
Definition Bytes of EGPRS DL RLC lost on PDTCH
Description This counter is not used for the time being.

C901030083
Definition Number of UL RLC Blocks lost
Description MS sends UL RLC data block to BSC by BTS. The counter keeps
record of the number of data blocks lost during packet
transmission.
Usage This counter is used to find out the number of RLC data blocks
lost on PDTCH.
Measurement The counter increments when UL RLC data blocks from BTS get
Point lost. The measurement point is A, as shown in Figure 58.

FIGURE 58 – MEASUREMENT POINT OF NUMBER OF UL RLC BLOCKS LOST

Unit Times

C901030084
Definition Bytes of GPRS UL RLC lost on PDTCH
Description MS sends UL RLC data block to BSC by BTS. The counter keeps
record of the number of CS-coded RLC bytes lost on PDTCH in
non-ack mode.
Usage This counter is used to find out the number of CS-coded RLC
bytes on UL PDTCH in non-ack mode.
Measurement The counter increments when CS-coded UL RLC block from BTS
Point gets lost. The measurement point is A, as shown in Figure 58.
Unit Byte

62 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Uplink/Downlink RLC Statistic Measurement

C901030085
Definition Bytes of EGPRS UL RLC lost on PDTCH
Description MS sends UL RLC data block to BSC by BTS. The counter keeps
record of the number of MCS-coded RLC bytes lost on PDTCH in
non-ack mode.
Usage This counter is used to find out the number of MCS-coded RLC
bytes on UL PDTCH in non-ack mode.
Measurement The counter increments when MCS-coded UL RLC block from
Point BTS gets lost. The measurement point is A, as shown in Figure
58.
Unit Byte

C901030086
Definition Number of standstill of GPRS UL TBF receiving window
Description This counter counts the number of standstill of UL receiving
window after UL GPRS TBF establishment.
Usage This counter is used to find out the number of standstill of UL
GPRS TBF receiving window.
Measurement „ The counter increments when receiving window is found to
Point come to a standstill in RLC layer after UL GPRS TBF
establishment. The measurement point is A, as shown in
Figure 59.

FIGURE 59 – MEASUREMENT POINT OF NUMBER OF STANDSTILL OF GPRS UL


TBF RECEIVING WINDOW

Unit Times

C901030087
Definition Number of standstill of EGPRS UL TBF receiving window
Description This counter counts the number of standstill of UL receiving
window after UL EGPRS TBF establishment.

Confidential and Proprietary Information of ZTE CORPORATION 63


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Usage This counter is used to find out the number of standstill of UL


EGPRS TBF receiving window.
Measurement The counter increments when receiving window is found to come
Point to a standstill in RLC layer after UL EGPRS TBF establishment.
Unit Times

C901030088
Definition Number of standstill of GPRS DL TBF sending window
Description This counter counts the number of standstill of DL sending
window after DL GPRS TBF establishment.
Usage This counter is used to find out the number of standstill of DL
GPRS TBF sending window.
Measurement The counter increments when sending window is detected to
Point stagnate during RLC block sending to BTS from BSC. The
measurement point is A, as shown in Figure 60.

FIGURE 60 – MEASUREMENT POINT OF NUMBER OF STANDSTILL OF GPRS DL


TBF SENDING WINDOW

Unit Times

C901030089
Definition Number of standstill of EGPRS DL TBF sending window
Description This counter counts the number of standstill of DL sending
window after DL EGPRS TBF establishment.
Usage This counter is used to find out the number of standstill of DL
EGPRS TBF sending window.
Measurement The counter increments when sending window is detected to
Point standstill during RLC block sending to BTS from BSC. The
measurement point is A, as shown in Figure 60.
Unit Times

64 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Uplink/Downlink RLC Statistic Measurement

C901030090
Definition Number of increment of DL coding mode
Description BSC will adjust DL coding scheme based on measurement report
when sending DL RLC blocks to BTS. This counter counts the
number of DL coding scheme increase.
Usage This counter is used to find out the increase of DL RLC block
coding scheme.
Measurement The counter increments when coding scheme of DL RLC blocks
Point sending to BTS from BSC is increased. The measurement point is
A as shown in Figure 61 (for EDGE) and Figure 62 (for GPRS).

FIGURE 61 – MEASUREMENT POINT OF NUMBER OF INCREMENT OF DL


CODING MODE (EDGE RLC BLOCK)

FIGURE 62 – MEASUREMENT POINT OF NUMBER OF INCREMENT OF DL


CODING MODE (GPRS RLC BLOCK)

Unit Times

C901030091
Definition Number of decrement of DL coding mode
Description BSC will adjust DL coding scheme based on measurement report
when sending DL RLC blocks to BTS. This counter counts the
number of DL coding scheme decrease.
Usage This counter is used to find out the decrease of DL RLC block
coding scheme.

Confidential and Proprietary Information of ZTE CORPORATION 65


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement The counter increments when coding scheme of DL RLC blocks


Point sending to BTS from BSC is decreased. The measurement point
is A as shown in Figure 61 (for EDGE) and Figure 62 (for GPRS).
Unit Times

C901030092
Definition Number of increment of UL coding mode
Description BSC will adjust UL coding scheme based on measurement report
when sending UL RLC blocks to BTS. This counter counts the
number of UL coding scheme increase.
Usage This counter is used to find out the increase of UL RLC block
coding scheme.
Measurement The counter increments when coding scheme of UL RLC blocks is
Point increased. The measurement point is A, as shown in Figure 63.

FIGURE 63 – MEASUREMENT POINT OF NUMBER OF INCREMENT OF UL


CODING MODE

Unit Times

C901030093
Definition Number of decrement of UL coding mode
Description BSC will adjust UL coding scheme based on measurement report
when sending UL RLC blocks to BTS. This counter counts the
number of UL coding scheme decrease.
Usage This counter is used to find out the decrease of UL RLC block
coding scheme.
Measurement The counter increments when coding scheme of UL RLC blocks
Point sending to BTS from BSC is decreased. The measurement point
is A, as shown in Figure 63
Unit Times

66 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Uplink/Downlink RLC Statistic Measurement

C901030094
Definition Number of conversion from GMSK to 8PSK
Description This counter counts the number of the handover of modulation
mode from GMSK to 8PSK.
Usage This counter is used to find out the number of the handover
from GMSK to 8PSK of RLC data block .
Measurement The counter increments When coding scheme of RLC block is
Point changed from GMSK to 8PSK (MCS5~MCS9). The measurement
point is A, as shown in Figure 61, Figure 62, and Figure 63.
Unit Times

C901030095
Definition Number of conversion from 8PSK to GMSK
Description This counter counts the number of the handover of modulation
mode from 8PSK to GMSK.
Usage This counter is used to find out the number of the handover
from 8PSK to GMSK of RLC data block.
Measurement The counter increments when coding scheme of RLC block is
Point changed from 8PSK to GMSK (from MCS5~MCS9 to other). The
measurement point is A, as shown in Figure 61, Figure 62, and
Figure 63.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 67


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

68 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5

PS Resource Used
Statistic Measurement

PS resource used statistic aims to measure the situation of PS


resource using in each cell.
This chapter describes the definition, usage and measurement
point of various counters.

Overview
Statistic counters are used to measure the PS resource usage in
each cell, including number of usable PS channels, average and
max number of busy PS channels, total busy time of PS channels,
total time of PS channel congestion and using of PS channels.
The measurement takes cell as the statistics unit.

PS Resource Used Statistic


Measurement Counters
Table 9 lists counters related to PS resource used statistic
measurement.

TABLE 9 – PS RESOURCE USED STATISTIC MEASUREMENT COUNTERS

Counter ID What It Counts


C901040001 Max number of Abis TS used
C901040002 Average number of Abis TS used
C901040004 Average number of unavailable PDCH
C901040005 Number of available static PDCH
C901040006 Number of unavailable static PDCH

Confidential and Proprietary Information of ZTE CORPORATION 69


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter ID What It Counts


C901040009 Time of DL PDCH congestion
C901040010 Time of UL PDCH congestion
C901040011 Time of PDCH used at least one UL/DL TBF exists
C901040012 Time of PDCH used at least one UL/DL EGPRS TBF
exists
C901040013 Time of PDCH used at least one DL TBF exists
C901040014 Time of PDCH used at least one UL TBF exists
C901040018 Number of immediate assignment on AGCH
C901040019 Number of paging PS requests on PCH
C901040020 Number of paging CS requests on PCH
C901040021 Number of immediate assignment on PCH
C901040022 Number of immediate assignment on PAGCH
C901040023 Number of paging PS requests on PPCH
C901040024 Number of paging CS requests on PPCH
C901040025 Number of immediate assignment on PPCH
C901040026 Number of Sig blks prach load
C901040027 Sum of Abis TS used sampling
C901040028 Number of Abis TS used sampling
C901040029 Sum of PDCH used sampling
C901040030 Number of PDCH used sampling
C901040031 Maximum value of Abis TS used to CS
C901040032 Minimum value of Abis TS used to CS
C901040033 Total value of the regular sampling used to CS
C901040034 Number of sampling of CS
C901040035 Maximum value of Abis TS used to PS
C901040036 Minimum value of Abis TS used to PS
C901040037 Total value of the regular sampling used to PS
C901040038 Number of sampling of PS

C901040001
Definition Max number of Abis TS used
Description This counter counts the max number of Abis TS used under TDM
connection between cell and site during measurement period.
The counter value reflects the instant Abis resource occupation
and max busyness.

70 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - PS Resource Used Statistic Measurement

Usage This counter is used to find out the current cell’s requirements
for Abis resource, which helps to adjust or expand Abis resource.
Measurement Inquire the database when periodic measurement data report to
Point get the counter value.
Unit Times

C901040002
Definition Average number of Abis TS used
Description This counter counts the average number of Abis TS used under
TDM connection between cell and site during measurement
period.
Usage This counter is used to find out the Abis resource occupation by
the current cell, which helps to adjust or expand Abis resource.
Measurement Inquire the database when periodic measurement data report to
Point get the counter value.
Unit Times

C901040004
Definition Number of unavailable PDCH
Description This counter counts the number of PDCHs that are not assigned
normally, including blocked dynamic PDCHs due to various
causes and static PDCHs.
Usage This counter is used to find out the number of unavailable
PDCHs, which helps to find out the trouble cause and make
troubleshooting in time.
Measurement Inquire the database when periodic measurement data report to
Point get the counter value.
Unit Times

C901040005
Definition Number of available static PDCH
Description iBSC supports dynamic wireless channels. This counter counts
the number of available PDCHs configured via OMCR in the
current cell.
Usage This counter is used to find out the number of available static
PDCHs in the current cell, which helps to make troubleshooting.
Measurement Inquire the database when periodic measurement data report to
Point get the counter value.

Confidential and Proprietary Information of ZTE CORPORATION 71


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Unit Times

C901040006
Definition Number of unavailable static PDCH
Description iBSC supports dynamic wireless channels. This counter counts
the number of unavailable PDCHs configured via OMCR in the
current cell.
Usage This counter is used to find out the number of unavailable static
PDCHs in the current cell, which helps to make troubleshooting.
Measurement Inquire the database when periodic measurement data report to
Point get the counter value.
Unit Times

C901040009
Definition Time of DL PDCH congestion
Description This counter counts the time during which the service instance
fails to apply DL PDCHs (namely the total time of DL PDCH
congestion).
If DL PDCH application fails, BSC records the congestion label
and the time when congestion starts. If DL PDCH application
succeeds, BSC clears the congestion label. When applying for DL
PDCH, if the congestion label is set, the current time minus the
congestion time of the previous record leaves the new
congestion time.
Before DL PDCH is released, if the congestion label is set, such
calculation repeats. When getting the periodic measurement
value, if the congestion label is set, such calculation repeats. The
accumulation of these calculations makes the total time of DL
PDCH congestion.
Usage This counter is used to find out the busyness of DL PDCH, which
may be used as a reference for whether more PDCHs should be
configured.
Measurement The measurement is taken at three time points listed below:
Point
„ Before DL PDCH attempts to occupy, if the congestion label
is set, this counter calculates the congestion time and
accumulates them.
„ Before DL PDCH is released, if the congestion label is set,
this counter calculates the congestion time and accumulates
them.
„ When reporting the measurement data periodically, if the
congestion label is set, this counter calculates the congestion
time and accumulates them.

72 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - PS Resource Used Statistic Measurement

Unit Second

C901040010
Definition Time of UL PDCH congestion
Description This counter counts the time during which the service instance
fails to apply UL PDCHs (namely the total time of UL PDCH
congestion).
If UL PDCH application fails, BSC records the congestion label
and the time when congestion starts. If UL PDCH application
succeeds, BSC clears the congestion label. When applying for UL
PDCH, if the congestion label is set, the current time minus the
congestion time of the previous record leaves the new
congestion time.
Before UL PDCH is released, if the congestion label is set, such
calculation repeats. When getting the periodic measurement
value, if the congestion label is set, such calculation repeats. The
accumulation of these calculations makes the total time of UL
PDCH congestion.
Usage This counter is used to find out the busyness of UL PDCH, which
may be used as a reference for whether more PDCHs should be
configured.
Measurement The measurement is taken at three time points listed below:
Point
„ Before UL PDCH attempts to occupy, if the congestion label is
set, this counter calculates the congestion time and
accumulates them.
„ Before UL PDCH is released, if the congestion label is set,
this counter calculates the congestion time and accumulates
them.
„ When reporting the measurement data periodically, if the
congestion label is set, this counter calculates the congestion
time and accumulates them.
Unit Second

C901040011
Definition Time of PDCH used at least one UL/DL TBF exists
Description When there is at least one UL TBF or DL TBF in one PDCH, this
PDCH is regarded to be used. This counter counts the time of
PDCH used. The value of the counter reflects the PDCH traffic.
Usage This counter is used to find out the using of PDCHs, which may
be used as a reference for whether more PDCHs should be
configured.

Confidential and Proprietary Information of ZTE CORPORATION 73


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement The measurement is taken at three time points listed below:


Point
„ When PDCH resource is acquired successfully, this counter
calculates and accumulates.
„ When PDCH resource is released, this counter calculates and
accumulates.
„ When reporting the measurement data periodically, this
counter calculates and accumulates.
Unit Second

C901040012
Definition Time of PDCH used at least one UL/DL EGPRS TBF exists
Description When there is at least one UL EGPRS TBF or DL EGPRS TBF in
one PDCH, this PDCH is regarded to be used by EGPRS. This
counter counts the time of PDCH used by EGPRS. The value of
the counter reflects the PDCH traffic.

Usage This counter is used to find out the using of EGPRS in PDCH,
which may be used as a reference for whether more PDCHs
should be configured.
Measurement The measurement is taken at three time points listed below:
Point
„ When PDCH resource is acquired successfully, this counter
calculates and accumulates.
„ When PDCH resource is released, this counter calculates and
accumulates.
„ When reporting the measurement data periodically, this
counter calculates and accumulates.
Unit Second

C901040013
Definition Time of PDCH used at least one DL TBF exists
Description When there is at least one DL TBF in one PDCH, this PDCH is
regarded to be used. This counter counts the time of PDCH used
by DL. The value of the counter reflects the PDCH traffic.
Usage This counter is used to find out the using of PDCHs, which may
be used as a reference for whether more PDCHs should be
configured.
Measurement The measurement is taken at three time points listed below:
Point
„ When PDCH resource is acquired successfully, this counter
calculates and accumulates.

74 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - PS Resource Used Statistic Measurement

„ When PDCH resource is released, this counter calculates and


accumulates.
„ When reporting the measurement data periodically, this
counter calculates and accumulates.
Unit Second

C901040014
Definition Time of PDCH used at least one UL TBF exists
Description When there is at least one UL TBF in one PDCH, this PDCH is
regarded to be used. This counter counts the time of PDCH used
by UL. The value of the counter reflects the PDCH traffic.
Usage This counter is used to find out the using of PDCHs, which may
be used as a reference for whether more PDCHs should be
configured.
Measurement The measurement is taken at three time points listed below:
Point
„ When PDCH resource is acquired successfully, this counter
calculates and accumulates.
„ When PDCH resource is released, this counter calculates and
accumulates.
„ When reporting the measurement data periodically, this
counter calculates and accumulates.
Unit Second

C901040018
Definition Number of immediate assignment on AGCH
Description This counter counts the number of Imm Assign message sent on
AGCH by BSC.
Usage This counter is used to find out the frequency of sending Imm
Assign message on AGCH by BSC in the current cell.
Measurement If BSC starts UL single block or UL TBF channel assignment,
Point when non-DRX MS assigns DL TBF, the counter increments. The
measurement points are A1 and A2 as shown in Figure 64 and
Figure 65.

Confidential and Proprietary Information of ZTE CORPORATION 75


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 64 - SENDING INSTANT ASSIGNMENT MESSAGE BY AGCH CHANNEL


(1)

FIGURE 65 - SENDING INSTANT ASSIGNMENT MESSAGE BY AGCH CHANNEL


(2)

Unit Times

C901040019
Definition Number of paging PS requests on PCH
Description This counter counts the number of Paging PS message sent on
PCH by BSC.
Usage This counter is used to find out the frequency of sending Paging
PS message on PCH by BSC in the current cell.
Measurement When BSC sends Paging PS message on PCH, the counter
Point increments. The measurement point is A as shown in Figure 66.

FIGURE 66 - SENDING PS PAGING BY PCH CHANNEL

76 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - PS Resource Used Statistic Measurement

Unit Times

C901040020
Definition Number of paging CS requests on PCH
Description This counter counts the number of Paging CS message sent on
PCH by BSC.
Usage This counter is used to find out the frequency of sending Paging
CS message on PCH by BSC in the current cell.
Measurement When BSC sends Paging CS message on PCH, the counter
Point increments. The measurement point is A as shown in Figure 67.

FIGURE 67 - SENDING CS PAGING BY PCH CHANNEL

MS BSS SGSN

PAGING CS

A
PAG REQ

Unit Times

C901040021
Definition Number of immediate assignment on PCH
Description This counter counts the number of Imm Assign message sent on
PCH by BSC.
Usage This counter is used to find out the frequency of sending Imm
Assign message on PCH by BSC in the current cell.
Measurement If BSC starts to establish DL TBF, when DRX MS sends Imm
Point Assign message on PCH, the counter increments. The
measurement point is A2, as shown in Figure 65.
Unit Times

C901040022
Definition Number of immediate assignment on PAGCH
Description This counter counts the number of Imm Assign message sent on
PAGCH by BSC.
Usage This counter is used to find out the frequency of sending Imm
Assign message on PAGCH by BSC in the current cell.

Confidential and Proprietary Information of ZTE CORPORATION 77


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement If BSC starts UL single block or UL TBF channel assignment,


Point when non-DRX MS assigns DL TBF, the counter increments. The
measurement points are A1 and A2, as shown in Figure 68 and
Figure 69.

FIGURE 68 – SENDING ASSIGNMENT MESSAGE BY P AGCH CHANNEL (1)

FIGURE 69 – SENDING ASSIGNMENT MESSAGE BY P AGCH CHANNEL (2)

Unit Times

C901040023
Definition Number of PS paging requests on PPCH
Description This counter counts the number of Paging PS message sent on
PPCH by BSC.
Usage This counter is used to find out the frequency of sending Paging
PS message on PPCH by BSC in the current cell.
Measurement When BSC sends Paging PS message on PPCH, the counter
Point increments. The measurement point is A, as shown in Figure 66.
Unit Times

C901040024
Definition Number of CS paging requests on PPCH

78 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - PS Resource Used Statistic Measurement

Description This counter counts the number of Paging CS message sent on


PPCH by BSC.
Usage This counter is used to find out the frequency of sending Paging
CS message on PPCH by BSC in the current cell.
Measurement When BSC sends Paging CS message on PPCH, the counter
Point increments. The measurement point is A, as shown in Figure 67.
Unit Times

C901040025
Definition Number of immediate assignment on PPCH
Description This counter counts the number of Imm Assign message sent on
PPCH by BSC.
Usage This counter is used to find out the frequency of sending Imm
Assign message on PPCH by BSC in the current cell.
Measurement If BSC starts to establish DL TBF, when DRX MS sends Imm
Point Assign message on PPCH, the counter increments. The
measurement point is A2, as shown in Figure 69.
Unit Times

C901040026
Definition Number of Sig blks prach load
Description This counter counts the number of EGPRS Packet Channel
Request message or Packet Channel Request message received
by BSC in PRACH.
Usage This counter is used to find out the load of PRACH in the current
cell, which may be used as a reference for whether more
PRACHs should be configured.
Measurement When BSC receives EGPRS Packet Channel Request message or
Point Packet Channel Request message, the counter increments. The
measurement point is A, as shown in Figure 70.

FIGURE 70 – NUMBER OF PACKET CHANNEL REQUESTS ON PRACH

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 79


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901040027
Definition Sum of Abis TS used sampling
Description This counter counts the total number of used Abis TS under TDM
connection between BSC and BS.
Usage This counter is used to find out the sum of Abis TS used
sampling. It is one of the parameters to observe the Abis TS
using.
Measurement When the database of BSC starts to assign Abis TS, the counter
Point accumulates.
Unit Times

C901040028
Definition Number of Abis TS used sampling
Description This counter counts the number of Abis TS assignments by
database.
Usage This counter is used to find out the frequency of Abis TS
assignment sampling. It is one of the parameters to observe the
Abis TS using.
Measurement When the database assigns Abis TS, the counter increments.
Point

Unit Times

C901040029
Definition Sum of PDCH used sampling
Description This counter counts the sum of PDCHs assigned by database
when service processing module starts PS channel request.
Usage This counter is used to find out the sum of PDCHs assigned by
database when service processing module starts PS channel
request. It is one of the parameters to observe multi-TS using
when assigning PS channels in the current cell.
Measurement When service processing module starts PS channel request and
Point database assigns PDCH, the counter accumulates.
Unit Times

C901040030
Definition Number of PDCH used sampling

80 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - PS Resource Used Statistic Measurement

Description This counter counts the number of PDCH assigning attempts by


database when service processing module starts PS channel
request.
Usage This counter is used to find out the frequency of PDCH assigning
by database when service processing module starts PS channel
request. It is one of the parameters to observe multi-TS using
when assigning PS channels in the current cell.
Measurement When service processing module starts PS channel request and
Point database assigns PDCH, the counter increments.
Unit Times

C901040031
Definition Maximum value of Abis TS used to CS
Description This counter counts the maximum value of Abis timeslot used in
CS service in the cell within the measurement period; for IP-
access sites, it counts the maximum bandwidth occupied by CS
service. This counter reflects the transcient occupation and the
busiest level of Abis resource in the cell's CS service.
Usage This counter is used to find out the Abis resource occupation in
the cell's CS service, which helps adjust the usage of Abis
resource.
Measurement The counter counts when CS user requests for the Abis resource
Point successfully.
Unit Number of (TDM access)/kbps (IP access)

C901040032
Definition Minimum value of Abis TS used to CS
Description This counter counts the minimum value of Abis timeslot used in
CS service in the cell within the measurement period; for IP-
access sites, it counts the minimum bandwidth occupied by CS
service.
Usage This counter is used to find out the Abis resource occupation in
the cell's CS service, which helps adjust the usage of Abis
resource.
Measurement The counter counts when CS user requests for the Abis resource
Point successfully or releases the Abis resource successfully.
Unit Number of (TDM access)/kbps (IP access)

Confidential and Proprietary Information of ZTE CORPORATION 81


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901040033
Definition Total value of the regular sampling used to CS
Description The counter accumulates at each measurement point. It counts
the accumulated Abis timeslot used by CS service within the
measurement period; for IP-access sites, it counts the
accumulated bandwidth occupied by CS service. With this
counter and C901040034, the system can get the average usage
of Abis resource occupied by CS service within the measurement
period.
Usage This counter reflects the average occupation of Abis resource in
CS service.
Measurement The counter accumulates when CS user requests for the Abis
Point resource successfully or releases the Abis resource successfully.
Unit Number of (TDM access)/kbps (IP access)

C901040034
Definition Number of sampling of CS
Description The counter increments at the measurement point of
C901040033. This counter and C901040033 reflect the average
occupation of Abis resource in the cell's CS service.
Usage This counter reflects the average occupation of Abis resource in
CS service.
Measurement The counter accumulates when CS user requests for the Abis
Point resource successfully or releases the Abis resource successfully.
Unit Number of (TDM access)/kbps (IP access)

C901040035
Definition Maximum value of Abis TS used to PS
Description This counter counts the maximum value of Abis timeslot used in
PS service in the cell within the measurement period; for IP-
access sites, it counts the maximum bandwidth occupied by PS
service. This counter reflects the transcient occupation and the
busiest level of Abis resource in the cell's PS service.
Usage This counter is used to find out the Abis resource occupation in
the cell's PS service, which helps adjust the usage of Abis
resource.
Measurement The counter counts when PS user requests for the Abis resource
Point successfully.
Unit Number of (TDM access)/kbps (IP access)

82 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - PS Resource Used Statistic Measurement

C901040036
Definition Minimum value of Abis TS used to PS
Description This counter counts the minimum value of Abis timeslot used in
PS service in the cell within the measurement period; for IP-
access sites, it counts the minimum bandwidth occupied by PS
service.
Usage This counter is used to find out the Abis resource occupation in
the cell's PS service, which helps adjust the usage of Abis
resource.
Measurement The counter counts when PS user requests for the Abis resource
Point successfully or releases the Abis resource successfully.
Unit Number of (TDM access)/kbps (IP access)

C901040037
Definition Total value of the regular sampling used to PS
Description The counter accumulates at each measurement point. It counts
the accumulated Abis timeslot used by PS service within the
measurement period; for IP-access sites, it counts the
accumulated bandwidth occupied by PS service. With this
counter and C901040038, the system can get the average usage
of Abis resource occupied by PS service within the measurement
period.
Usage This counter reflects the average occupation of Abis resource in
PS service.
Measurement The counter accumulates when PS user requests for the Abis
Point resource successfully or releases the Abis resource successfully.
Unit Number of (TDM access)/kbps (IP access)

C901040038
Definition Number of sampling of PS
Description The counter increments at the measurement point of
C901040037. This counter and C901040037 reflect the average
occupation of Abis resource in the cell's PS service.
Usage This counter reflects the average occupation of Abis resource in
PS service.
Measurement The counter accumulates when PS user requests for the Abis
Point resource successfully or releases the Abis resource successfully.
Unit Number of (TDM access)/kbps (IP access)

Confidential and Proprietary Information of ZTE CORPORATION 83


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

84 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6

RMM Assignment
Measurement

RMM assignment measurement describes assignment status,


including assignment attempt, execution and queuing due to
various reasons. This chapter contains definitions, usages and
measurement points of counters in assignment measurement.

Overview
RMM assignment counter describers the assignment process. As
many attempts can be made if no channel is available in the first
assignment attempt, it is necessary to make a completed
description of the whole assignment process instead of the
assignment processes of TCH/F or TCH/H. These counters are
used to analyze influences of forced release, queuing and
directed retry, to assignment success rate from the viewpoint of
calling.

RMM Assignment Measurement


Counter Index
Table 10 lists counters related to RMM assignment measurement.

TABLE 10 – RMM ASSIGNMENT MEASUREMENT COUNTERS

Counter What It Counts


Number of general assignment executions
C901050001
for voice channel
Number of assignments attempts for voice
C901050002
due to forced release
Number of assignment executions for
C901050003
voice channel due to forced release

Confidential and Proprietary Information of ZTE CORPORATION 85


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter What It Counts


Number of handover attempts for voice
C901050004
due to forced release
Number of handover executions for voice
C901050005
channel due to forced release
Number of assignments for voice channel
C901050006
due to queuing
Number of assignments for execution for
C901050007
voice channel due to queuing
Duration of assignment success voice
C901050008
channel due to queuing
Number of assignments success for voice
C901050009
channel due to queuing
Number of assignments for directed retry
C901050010
attempts for voice channel
Number of assignments for execution for
C901050011
voice channel due to directed retry
Number of general assignments for
C901050012
execution for data
Number of assignments attempts for data
C901050013
due to forced release
Number of assignment executions for data
C901050014
due to forced release
Number of handover attempts for data due
C901050015
to forced release
Number of handover executions for data
C901050016
due to forced release
Number of assignments attempts for data
C901050017
due to queuing
Number of assignments for execution for
C901050018
data due to queuing
Total duration of successful assignments
C901050019
for data due to queuing
Number of assignments success due to
C901050020
queuing
Number of assignments attempts for data
C901050021
due to directed retry
Number of assignment executions for data
C901050022
due to directed retry
Number of assignment for retry attempts
C901050023
FDD cell for voice channel
Number of assignment executions for data
C901050024 due to directed retry to FDD cell for voice
channel
Number of assignment for retry attempts
C901050025
FDD cell for data

86 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

Counter What It Counts


Number of assignment executions for data
C901050026
due to directed retry to FDD cell for data
Number of assignment for retry attempts
C901050027
TDD cell for voice channel
Number of assignment executions for data
C901050028 due to directed retry to TDD cell for voice
channel
Number of assignment for retry attempts
C901050029
TDD cell for data
Number of assignment executions for data
C901050030
due to directed retry to TDD cell for data
Assignment unsuccessful due to circuit
C901050031
obstruction
Assignment unsuccessful due to circuit
C901050032
obstruction unmatched
Assignment unsuccessful due to no valid
C901050033
radio resource
Assignment unsuccessful due to other
C901050034
causes
Number of assignments attempts due to
C901050035
forced release (emergency service)
Number of assignment executions channel
C901050036
due to forced release (emergency service)
Number of assignment attempts due to
C901050037
forced handover (emergency service)
Number of assignment executions channel
C901050038 due to forced handover (emergency
service)
Number of assignments channel due to
C901050039
queuing (emergency service)
Number of assignments for execution
C901050040 channel due to queuing (emergency
service)
Number of forced handover target not
C901050041
found (assignment forced handover)
Number of send forced handover request
C901050042 to lower PRI user (assignment forced
handover)
Number of received failure from lower PRI
C901050043 user request resource for forced handover
(assignment forced handover)
Number of lower PRI user handover failure
C901050044
(assignment forced handover)
Number of time out for wait resource
C901050045
(assignment forced handover)
C901050046 Number of forced release target not found

Confidential and Proprietary Information of ZTE CORPORATION 87


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter What It Counts


(assignment forced release)
Number of time out for wait resource
C901050047
(assignment forced release)
Number of get before grab released
C901050048
channel (assignment forced handover)
Number of get before grab released
C901050049
channel(assignment forced release)

C901050001
Definition Number of general assignment executions for voice channel
Description The way for BSC to get TCH in voice channel assignment process
includes normal request, and queuing attempt or forced release
if normal request is failed. This counter counts the number of
general assignment executions for voice channel.
Usage This counter is used to find out the number of available TCH in
normal request in voice channel assignment flow; this counter
can be used to check whether the cell has enough available
radio resource.
Measurement In voice channel assignment flow, the counter increments when
Point source cell receives message that resource is available from
target cell after sending channel request, and successfully sends
assignment command. The measurement point is A, as shown in
Figure 71.

FIGURE 71 - MEASUREMENT POINT OF GENERAL ASSIGNMENT EXECUTIONS

Unit Times

C901050002
Definition Number of assignments attempts for voice due to forced release

88 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

Description BSC attempts to allocate voice channel after receiving “Radio


App” message in assignment flow; if there is no proper channel
available and the system allows forced release, then BSC carries
out forced release to other channels. This counter counts the
number of forced release.
Usage This counter is used to find out the number of assignments for
forced release attempts in MS accessing process.
Measurement BSC fails in allocating channel due to no available resource. It
Point releases other channels forcedly when the system allows.
„ The counter increments when BSC fails in general voice
channel assignment and the system allows forced release
and finds a proper instance of forcing release that sends
“forced release” message to instance of forced release.
„ The counter increments when BSC fails in general voice
channel assignment and queuing attempt fails due to
overtime and the system allows forced release and there is a
proper instance of forced release that sends “forced release”
message to instance of forced release. The measurement
point is A, as shown in Figure 72.

FIGURE 72 - MEASUREMENT POINT OF ASSIGNMENTS FOR FORCED RELEASE


ATTEMPTS

Unit Times

C901050003
Definition Number of assignment executions for voice channel due to
forced release
Description BSC fails in allocating voice channel due to no available resource
and carries out forced release; if BCS gets required channel in
time, then the forced release succeeds. This counter counts the

Confidential and Proprietary Information of ZTE CORPORATION 89


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

number of assignment executions for voice channel due to


forced release.
Usage This counter is used to find out the number of assignment
executions for voice channel due to forced release in MS
accessing process.
Measurement The counter increments if radio resource request fails in voice
Point channel assignment, forced released can be carried out and
instance of forcing release sends “forced release” message to
instance of forced release, and “resource available” message is
received and channel is obtained successfully. The measurement
point is B, as shown in Figure 73.

F I G U R E 7 3 - M e a s u r e m e n t P o i n t o f As s i g n m e n t E x e c u t i o n s f o r V o i c e
Channel due to Forced Release

Unit Times

C901050004
Definition Number of handover attempts for voice due to forced release
Description BSC attempts to operate outgoing handover to the cell voice
channel for forced release when it fails in voice channel
allocation due to no available resource. The counter counts the
number of handover for forced release attempts for voice
channel.
Usage This counter is used to find out the number of handover for
forced release attempts for voice channel in MS accessing
process.
Measurement The counter increments when BSC fails in general voice channel
Point assignment and the system allows forced release and there is
proper instance of forcing release that sends “forced release”

90 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

message to instance of forced release. The measurement point


is A, as shown in Figure 74.

FIGURE 74 - Measurement Point of Handover for Forced Release


Attempts

Unit Times

C901050005
Definition Number of handover executions for voice channel due to forced
release
Description BSC attempts to operate outgoing handover to the cell voice
channel for forced release when it fails in voice channel
allocation due to no available resource. The counter counts the
number of handover executions for voice channel due to forced
release.
Usage This counter is used to find out the number of handover
executions for voice channel due to forced release in MS
accessing process.
Measurement The counter increments if radio resource request fails in voice
Point channel assignment, handover for voice channel due to forced
release can be carried out and instance of forcing handover
sends “forced handover” message to instance of forced handover,
and “resource available” message is received and channel is
obtained successfully. The measurement point is B, as shown in
Figure 75.

Confidential and Proprietary Information of ZTE CORPORATION 91


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 75 – MEASUREMENT POINT OF HANDOVER EXECUTIONS FOR VOICE


CHANNEL DUE TO FORCED RELEASE

Unit Times

C901050006
Definition Number of assignments for voice channel due to queuing
Description BSC attempts to assign voice channel after receiving “Radio
App” message in assignment flow; if there is no proper channel
available and the system doesn’t allow forced release or can’t
find instance of forcing release but allows queuing, then the
present instance queues and waits till other resource releases.
This counter counts the number of assignments for queuing
attempts for voice channel.
Usage This counter is used to find out the number of assignments for
queuing attempts for voice channel in MS accessing process.
Measurement The counter increments when BSC fails in general voice channel
Point assignment and the system allows queuing and the instance
queues. The measurement point is A, as shown in Figure 76.

92 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

FIGURE 76 - MEASUREMENT POINT OF ASSIGNMENTS FOR QUEUING


ATTEMPTS

Unit Times

C901050007
Definition Number of assignments for execution for voice channel due to
queuing
Description BSC fails in allocating voice channel due to no available resource
and carries out queuing; if BCS gets required channel in time,
then the queuing succeeds. This counter counts the number of
assignments for execution for voice channel due to queuing.
Measurement The counter increments if radio resource request fails in voice
Point channel assignment, queuing can be carried out and instance of
queuing receives “resource available” message and obtains
channel successfully. The measurement point is B, as shown in
Figure 77.

Confidential and Proprietary Information of ZTE CORPORATION 93


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 77 – MEASUREMENT POINT OF Assignments for Execution for Voice


Channel due to Queuing

Unit Times

C901050008
Definition Duration of assignment success voice channel due to queuing
Description This counter counts the total duration of successful assignment
for queuing voice channel in allocation process.
The duration of successful assignment for queuing for voice
channel is the time when channel is obtained minus the time
when the instance began to queue. The counter accumulates the
total durations of successful assignment for queuing for voice
channel.
Usage This counter is used to check the intra-cell queuing status and
represents whether queuing can relieve traffic congestion
effectively.
Measurement The counter accumulates duration of successful assignment for
Point queuing for voice channel if radio resource request fails in voice
channel assignment, queuing can be carried out and instance of
queuing receives “resource available” message and obtains
channel successfully. The measurement points are A and B, as
shown in Figure 77.
Unit Times

C901050009
Definition Number of assignments success for voice channel due to
queuing

94 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

Description This counter counts the number of successful assignments of


queuing for voice channel.
Usage This counter is used to check the intra-cell queuing status and
represents whether queuing can relieve traffic congestion
effectively.
Measurement The counter increments if radio resource request fails in voice
Point channel assignment, queuing can be carried out and instance of
queuing receives “resource available” message and obtains
channel successfully. The measurement point is B, as shown in
Figure 77.
Unit Times

C901050010
Definition Number of assignments for directed retry attempts for voice
channel
Description If BSC fails in voice channel request, and source cell allows
directed retry and target cell that meets the directed retry
demand can be selected from adjacent cells, then BSC carries
out directed retry. This counter counts the number of
assignments for directed retry attempts for voice channel.
Usage This counter is used to find out the number of assignments for
directed retry attempts for voice channel and check whether the
cell’s radio environment can satisfy the traffic demand.
Measurement The counter increments when source cell receives “no available
Point radio resource” message from target cell and source cell
supports directed retry and target cell that meets the directed
retry demand can be found and “Radio_App” message is sent to
target cell. The measurement point is A, as shown in Figure 78.

Confidential and Proprietary Information of ZTE CORPORATION 95


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

F I G U R E 7 8 – M e a s u r e m e n t P o i n t o f As s i g n m e n t s f o r D i r e c t e d R e t r y
Attempts

Unit Times

C901050011
Definition Number of assignments for execution for voice channel due to
directed retry
Description This counter counts the number of assignments for execution for
voice channel due to directed retry
Usage This counter is used to check the process and result of directed
retry.
Measurement The counter increments when directed retry is carried out and
Point target cell obtains channel successfully and source cell receives
“radio resource available” message from target cell in voice
channel assignment process. The measurement point is B, as
shown in Figure 79.

96 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

F I G U R E 7 9 – M e a s u r e m e n t P o i n t o f As s i g n m e n t s f o r E x e c u t i o n f o r V o i c e
Channel due to Directed Retry

Unit Times

C901050012
Definition Number of general assignments for execution for data
Description The way for BSC to get TCH in data channel assignment process
includes normal request, and queuing attempt or forced release
if normal request is failed. This counter counts the number of
general assignment executions for data channel.
Usage This counter is used to find out the number of available TCH in
normal request in data channel assignment flow; this counter
can be used to check whether cell has enough available radio
resource.
Measurement In data channel assignment flow, the counter increments when
Point source cell receives “resource is available” message from target
cell after sending channel request, and successfully sends
assignment command. The measurement point is A, as shown in
Figure 71.
Unit Times

C901050013
Definition Number of assignments attempts for data due to forced release
Description BSC attempts to allocate data channel after receiving “Radio
App” message in assignment flow; if there is no proper channel
available and the system allows forced release, then BSC carries

Confidential and Proprietary Information of ZTE CORPORATION 97


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

out forced release to other channels. This counter counts the


number of forced release.
Usage This counter is used to find out the number of assignments for
forced release attempts in MS accessing process.
Measurement BSC fails in allocating channel due to no available resource and
Point releases other channel forcedly when the system allows.
„ The counter increments when BSC fails in general data
channel assignment and the system allows forced release
and there is a proper instance of forcing release that sends
“forced release” message to instance of forced release.
„ The counter increments when BSC fails in general data
channel assignment and queuing attempt fails due to
overtime and the system allows forced release and finds a
proper instance of forcing release that sends “forced release”
message to instance of forced release. The measurement
point is A, as shown in Figure 72.
Unit Times

C901050014
Definition Number of assignment executions for data due to forced release
Description BSC fails in allocating data channel due to no available resource
and carries out forced release; if BCS gets required channel in
time, then the forced release succeeds. This counter counts the
number of assignment executions for data channel due to forced
release.
Usage This counter is used to find out the number of assignment
executions for data channel due to forced release in MS
accessing process.
Measurement The counter increments if radio resource request fails in data
Point channel assignment, forced released can be carried out and
instance of forcing release sends “forced release” message to
instance of forced release, and “resource available” message is
received and channel is obtained successfully. The measurement
point is B, as shown in Figure 73.
Unit Times

C901050015
Definition Number of handover attempts for data due to forced release
Description BSC attempts to operate outgoing handover to the cell data
channel for forced release when it fails in data channel allocation
due to no available resource. The counter counts the number of
handover for forced release attempts for data channel.

98 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

Usage This counter is used to find out the number of handover for
forced release attempts for data channel in MS accessing
process.
Measurement The counter increments when BSC fails in general data channel
Point assignment and the system allows forced release and there is
proper instance of forcing release that sends “forced release”
message to instance of forced release. The measurement point
is A, as shown in Figure 74.
Unit Times

C901050016
Definition Number of handover executions for data due to forced release
Description BSC attempts to operate outgoing handover to the cell data
channel for forced release when it fails in data channel allocation
due to no available resource. The counter counts the number of
handover executions for data channel due to forced release.
Usage This counter is used to find out the number of handover
executions for data channel due to forced release in MS
accessing process.
Measurement The counter increments if radio resource request fails in data
Point channel assignment, handover for data channel due to forced
release can be carried out and instance of forcing handover
sends “forced handover” message to instance of forced handover,
and “resource available” message is received and channel is
obtained successfully. The measurement point is B, as shown in
Figure 75.
Unit Times

C901050017
Definition Number of assignments attempts for data due to queuing
Description BSC attempts to assign data channel after receiving “Radio App”
message in assignment flow; if there is no proper channel
available and the system doesn’t allow forced release or can’t
find instance of forcing release but allows queuing, then the
present instance queues and waits till other resource releases.
This counter counts the number of assignments for queuing
attempts for data channel.
Usage This counter is used to find out the number of assignments for
queuing attempts for data channel in MS accessing process.
Measurement The counter increments when BSC fails in general data channel
Point assignment and the system allows queuing and the instance
queues. The measurement point is A, as shown in Figure 76.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 99


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901050018
Definition Number of assignments for execution for data due to queuing
Description BSC fails in allocating data channel due to no available resource
and carries out queuing; if BCS gets required channel in time,
then the queuing succeeds. This counter counts the number of
assignments for execution for data channel due to queuing.
Measurement The counter increments if radio resource request fails in data
Point channel assignment, queuing can be carried out and instance of
queuing receives “resource available” message and obtains
channel successfully. The measurement point is B, as shown in
Figure 77.
Unit Times

C901050019
Definition Total duration of successful assignments for data due to queuing
Description This counter counts the total duration of successful assignment
for queuing for data channel in allocation process.
The duration of successful assignment for queuing for data
channel is the time when channel is obtained minus the time
when the instance began to queue. The counter accumulates the
total durations of successful assignment for queuing for data
channel.
Usage This counter is used to check the intra-cell queuing status and
represents whether queuing can relieve traffic congestion
effectively.
Measurement The counter accumulates duration of successful assignment for
Point queuing for data channel if radio resource request fails in data
channel assignment, queuing can be carried out and instance of
queuing receives “resource available” message and obtains
channel successfully. The measurement points are A and B, as
shown in Figure 77.
Unit Times

C901050020
Definition Number of assignments success due to queuing
Description This counter counts the number of successful assignments of
queuing for data channel.
Usage This counter is used to check the intra-cell queuing status and
represents whether queuing can relieve traffic congestion
effectively.

100 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

Measurement The counter increments if radio resource request fails in data


Point channel assignment, queuing can be carried out and instance of
queuing receives “resource available” message and obtains
channel successfully. The measurement point is B, as shown in
Figure 77.
Unit Times

C901050021
Definition Number of assignments attempts for data due to directed retry
Description If BSC fails in data channel request, and source cell allows
directed retry and target cell that meets the directed retry
demand can be selected from adjacent cells, then BSC carries
out directed retry. This counter counts the number of
assignments for directed retry attempts for data channel.
Usage This counter is used to find out the number of assignments for
directed retry attempts for data channel and check whether the
cell’s radio environment can satisfy the traffic demand.
Measurement The counter increments when source cell receives “no available
Point radio resource” message from target cell and source cell
supports directed retry and target cell that meets the directed
retry demand can be found and “Radio_App” message is sent to
target cell. The measurement point is A, as shown in Figure 78.
Unit Times

C901050022
Definition Number of assignment executions for data due to directed retry
Description This counter counts the number of assignments for execution for
data channel due to directed retry
Usage This counter is used to check the process and result of directed
retry.
Measurement The counter increments when directed retry is carried out and
Point target cell successfully obtains channel and source cell receives
“radio resource available” message from target cell in data
channel assignment process. The measurement point is B, as
shown in Figure 79.
Unit Times

C901050023
Definition Number of assignment for retry attempts FDD cell for voice
channel

Confidential and Proprietary Information of ZTE CORPORATION 101


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of assignment for retry attempts
FDD cell for voice channel.
Usage This counter is used to find out the number of assignment for
retry attempts FDD cell for voice channel and represent FDD cell
traffic sharing status in voice channel assignment.
Measurement The counter increments in voice channel assignment when
Point source cell receives “no available radio resource” message from
FDD cell and source cell supports directed retry and FDD cell
that meets the directed retry demand can be found and
“Radio_App” message is sent to FDD cell. The measurement
point is A, as shown in Figure 78.
Unit Times

C901050024
Definition Number of assignment executions for data due to directed retry
to FDD cell for voice channel
Description This counter counts the number of assignment executions due to
directed retry to FDD cell for voice channel.
Usage This counter is used to find out the number of assignment
executions due to directed retry to FDD cell for voice channel
and represent FDD cell directed retry status.
Measurement The counter increments in voice channel assignment when
Point target cell in directed retry is FDD cell and successfully obtains
channel and source cell receives “resource available” message
from target cell. The measurement point is B, as shown in Figure
79.
Unit Times

C901050025
Definition Number of assignment for retry attempts FDD cell for data
Description This counter counts the number of assignment for retry attempts
FDD cell for data channel.
Usage This counter is used to find out the number of assignment for
retry attempts FDD cell for data channel and represent FDD cell
traffic sharing status in data channel assignment.
Measurement The counter increments in data channel assignment when source
Point cell receives “no available radio resource” message from FDD
cell and source cell supports directed retry and FDD cell that
meets the directed retry demand can be found and “Radio_App”
message is sent to FDD cell. The measurement point is A, as
shown in Figure 78.
Unit Times

102 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

C901050026
Definition Number of assignment executions for data due to directed retry
to FDD cell for data
Description This counter counts the number of assignment executions due to
directed retry to FDD cell for data channel.
Usage This counter is used to find out the number of assignment
executions due to directed retry to FDD cell for data channel and
represent FDD cell directed retry status.
Measurement The counter increments in data channel assignment when target
Point cell in directed retry is FDD cell and successfully obtains channel
and source cell receives “radio resource available” message from
target cell. The measurement point is B, as shown in Figure 79.
Unit Times

C901050027
Definition Number of assignment for retry attempts TDD cell for voice
channel
Description This counter counts the number of assignment for retry attempts
TDD cell for voice channel.
Usage This counter is used to find out the number of assignment for
retry attempts TDD cell for voice channel and represent TDD cell
traffic sharing status in voice channel assignment.
Measurement The counter increments in voice channel assignment when
Point source cell receives “no available radio resource” message from
TDD cell and source cell supports directed retry and TDD cell
that meets the directed retry demand can be found and
“Radio_App” message is sent to TDD cell. The measurement
point is A, as shown in Figure 78.
Unit Times

C901050028
Definition Number of assignment executions for data due to directed retry
to TDD cell for voice channel
Description This counter counts the number of assignment executions due to
directed retry to TDD cell for voice channel.
Usage This counter is used to find out the number of assignment
executions due to directed retry to TDD cell for voice channel
and represent TDD cell directed retry status.
Measurement The counter increments in voice channel assignment when
Point target cell in directed retry is TDD cell and successfully obtains

Confidential and Proprietary Information of ZTE CORPORATION 103


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

channel and source cell receives “radio resource available”


message from target cell. The measurement point is B, as shown
in Figure 79.
Unit Times

C901050029
Definition Number of assignment for retry attempts TDD cell for data
Description This counter counts the number of assignment for retry attempts
TDD cell for data channel.
Usage This counter is used to find out the number of assignment for
retry attempts TDD cell for data channel and represent TDD cell
traffic sharing status in data channel assignment.
Measurement The counter increments in data channel assignment when source
Point cell receives “no available radio resource” message from TDD
cell and source cell supports directed retry and TDD cell that
meets the directed retry demand can be found and “Radio_App”
message is sent to TDD cell. The measurement point is A, as
shown in Figure 78.
Unit Times

C901050030
Definition Number of assignment executions for data due to directed retry
to TDD cell for data
Description This counter counts the number of assignment executions due to
directed retry to TDD cell for data channel.
Usage This counter is used to find out the number of assignment
executions due to directed retry to TDD cell for data channel and
represent TDD cell directed retry status.
Measurement The counter increments in data channel assignment when target
Point cell in directed retry is TDD cell and successfully obtains channel
and source cell receives “radio resource available” message from
target cell. The measurement point is B, as shown in Figure 79.
Unit Times

C901050031
Definition Assignment unsuccessful due to circuit obstruction
Description This counter counts the number of the assignment failure due to
circuit obstruction on A-interface.
Usage

104 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

This counter is used to find out the number of assignment failure


due to circuit obstruction on A-interface and to check circuit
obstruction status on A-interface in assignment flow.
Measurement Target cell checks circuit after receiving “assignment request”
Point message sent by MSC; the counter increments if the circuit is
obstructed. The measurement point is A, as shown in Figure 80.

F I G U R E 8 0 – M e a s u r e m e n t P o i n t o f As s i g n m e n t F a i l u r e d u e t o C i r c u i t
Obstruction on A-Interface

BSC MSC

Ass
Request

The required circuit is obstructed


or circuit unmatched or channel
request fails or no response to
channel request or other reasons

A
Assignment
Fail

Unit Times

C901050032
Definition Assignment unsuccessful due to circuit obstruction unmatched
Description This counter counts the number of assignment failure due to
circuit unmatched on A-interface.
Usage This counter is used to find out the number of assignment failure
due to circuit unmatched on A-interface and to check circuit
unmatched status on A-interface in assignment flow.
Measurement Target cell checks circuit after receiving “assignment request”
Point message sent by MSC; the counter increments if the circuit is
unmatched. The measurement point is A, as shown in Figure 80.
Unit Times

C901050033
Definition Assignment unsuccessful due to no valid radio resource
Description This counter counts the number assignment failure due to no
valid radio resource.
Usage This counter is used to find out the number of assignment failure
due to no valid radio resource and to check radio resource
assignment status in assignment flow.

Confidential and Proprietary Information of ZTE CORPORATION 105


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement „ Source cell sends channel request to target cell after


Point receiving “assignment request” message; the counter
increments if channel request fails due to no valid radio
resource. The measurement point is A, as shown in Figure 80.
„ Source cell sends channel request to target cell after
receiving “assignment request” message; the counter
increments if Radio_App is overtime due to no responding
message. The measurement point is A, as shown in Figure
80.
Unit Times

C901050034
Definition Assignment unsuccessful due to other causes
Description This counter counts the number assignment failure due to other
causes on A-interface.
Usage This counter is used to find out the number of assignment failure
due to other causes and to check A-interface status in
assignment flow.
Measurement Target cell receives “assignment request” message sent by MSC;
Point the counter increments if assignment failure on A-interface is
caused by other causes (instead of the causes mentioned above,
such as circuit obstruction, circuit unmatched and no valid radio
resource). The measurement point is A, as shown in Figure 80.
Unit Times

C901050035
Definition Number of assignment attempts due to forced release
(emergency service)
Description In the assignment flow, after BSC receives the RADIO_APPLY
message, it attempts to assign the voice channel. If there is no
suitable channel and forced release is allowed, then it releases
other channels forcibly, if this call is an emergency call, then this
counter counts the number of forced release attempts.
Usage This counter is used to find out the number of assignment
attempts due to forced release during the MS access process of
an emergency call.
Measurement BSC fails to assign channel due to no available resource, if
Point forced release is allowed, BSC will forcibly release other
channels.
During an emergency call, BSC fails to assign voice channel. If
forced release is allowed and there is suitable forced release
instance, then the counter increments when the forcing release

106 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

instance sends the forced release message to the forced release


instance. The measurement point is A, as shown in Figure 81.

FIGURE 81 – MEASUREMENT POINT OF NUMBER OF ASSIGNMENT ATTEMPTS


DUE TO FORCED RELEASE (EMERGENCY SERVICE)

Unit Times

C901050036
Definition Number of assignment executions channel due to forced release
(emergency service)
Description BSC fails to assign voice channel due to no available resource, if
it obtains needed channel within specified time after the forced
release is performed, then the forced release is considered
successful. If the call is an emergency call, the counter counts
the number of successful forced releases (emergency service).
Usage This counter is used to find out the number of successful
assignments due to forced release during the MS access process
of an emergency call.
Measurement During the voice channel assignment process, if the radio
Point resource request fails and forced release is allowed, the forcing
release instance sends the forced release message to the forced
release instance. If the message of resource available is received,
then the resource is obtained successfully, and in this case, the
counter increments. The measurement point is B, as shown in
Figure 81.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 107


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901050037
Definition Number of assignment attempts due to forced handover
(emergency service)
Description When BSC fails to assign voice channel due to no available
resource, it attempts forced handover towards external cell. If
the call is an emergency call, the counter counts the number of
forced handover attempts.
Usage This counter is used to find out the number of assignment
attempts due to forced handover during the MS access process
of an emergency call.
Measurement During an emergency call, BSC fails to assign voice channel. If
Point forced handover is allowed and there is suitable forcing
handover instance, then the counter increments when the
forcing handover instance sends the forced handover message
to the forced handover instance. The measurement point is A, as
shown in Figure 74.
Unit Times

C901050038
Definition Number of assignment executions channel due to forced
handover(emergency service)
Description When BSC fails to assign voice channel due to no available
resource, it attempts forced handover towards external cell. If
the call is an emergency call, the counter counts the number of
successful forced handover.
Usage This counter is used to find out the number of successful
assignments due to forced handover during the MS access
process of an emergency call.
Measurement During the voice channel assignment process for emergency call,
Point if the radio resource request fails and forced handover is allowed,
the forcing handover instance sends the forced handover
message to the forced handover instance. If the message of
resource available is received, then the resource is obtained
successfully, and in this case, the counter increments. The
measurement point is B, as shown in Figure 75.
Unit Times

C901050039
Definition Number of assignments channel due to queuing (emergency
service)
Description

108 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

In the assignment flow, after BSC receives the RADIO_APPLY


message, it attempts to assign the voice channel. If there is no
suitable channel and queuing is allowed, then the instance
enters the queuing state and waits for other resource to be
released, if this call is an emergency call, then this counter
counts the number of queuing attempts (emergency service).
Usage This counter is used to find out the number of assignment
attempts due to queuing during the MS access process of an
emergency call.
Measurement During an emergency call, BSC fails to assign voice channel. If
Point queuing is allowed, then the instance is added to the queue and
the counter increments. The measurement point is A, as shown
in Figure 76.
Unit Times

C901050040
Definition Number of assignments for execution channel due to queuing
(emergency service)
Description During an emergency call, BSC fails to assign voice channel due
to no available resource but obtains needed channel within
specified time after the queuing is performed (no forced
handover or forced release is performed). In this case, the
queuing is considered successful, the counter counts the number
of successful assignments due to queuing (emergency service).
Usage This counter is used to find out the number of successful
assignments due to queuing during the MS access process of an
emergency call.
Measurement During the voice channel assignment process, if the radio
Point resource request fails and queuing is allowed, the counter
increments when the queuing instance receives the message of
resource available and obtains resource successfully. The
measurement point is B, as shown in Figure 77.
Unit Times

C901050041
Definition Number of forced handover target not found (assignment forced
handover)
Description When BSC fails to assign voice channel due to no available
resource, it attempts forced handover towards external cell. If
no forcing handover instance is found in the cell, the counter
counts the number of times that forcing handover target
instance is not found.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 109


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

During forced handover for voice channel assignment, this


counter is used to find out the number of times that forced
handover target instance is not found.
Measurement During an emergency call, BSC fails to assign voice channel. If
Point forced handover is allowed but there is no suitable forced
handover instance, then the counter increments. The
measurement point is A, as shown in Figure 82.

FIGURE 82 – MEASUREMENT POINT OF NUMBER OF FORCED HANDOVER


T AR G E T N O T FO U N D ( AS S I G N M E NT FO R CE D H AN D O V E R )

Unit Times

C901050042
Definition Number of send forced handover request to lower PRI user
(assignment forced handover)
Description When BSC fails to assign voice channel due to no available
resource, it attempts forced handover towards external cell. If
forced handover target instance is found in the cell, the counter
counts the number of forced handover requests sent to low
priority users during the force handover.
Usage During the voice channel assignment of MS access process, this
counter is used to find out the number of forced handover
requests when the forcing handover instance is found.
Measurement When BSC fails to assign voice channel, if forced handover is
Point allowed and there is suitable forcing handover instance, then the
counter increments when the forcing handover instance sends
the forced handover message to the forced handover instance.
The measurement point is A, as shown in Figure 74.
Unit Times

110 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

C901050043
Definition Number of received failure from lower PRI user request resource
for forced handover (assignment forced handover)
Description When BSC fails to assign voice channel due to no available
resource, it attempts forced handover towards external cell. If
forcing handover target instance is found in the cell, the forced
handover is initiated. Then, if the forced handover fails due to
resource request failure, the counter counts the number of
receiving resource request failure message from low priority
user during the forced handover.
Usage During the forced handover for voice channel assignment in MS
access process, this counter is used to find out the number of
receiving the forced handover failure message due to resource
request failure.
Measurement When BSC fails to assign voice channel, if forced handover is
Point allowed and there is suitable forcing handover instance, then the
counter increments in the following case: the forcing handover
instance sends the forced handover message to the forced
handover instance and simultaneously receives the forced
handover failure message which is due to resource request
failure. The measurement point is B, as shown in Figure 83.

FIGURE 83 – MEASUREMENT POINT OF NUMBER OF RECEIVING FORCED


HANDOVER FAILURE MESSAGE FROM LOW PRIORITY USER DURING FORCED
HANDOVER

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 111


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901050044
Definition Number of lower PRI user handover failure (assignment forced
handover)
Description When BSC fails to assign voice channel due to no available
resource, it attempts forced handover towards external cell. If
forcing handover target instance is found in the cell, the forced
handover is initiated. Then, if the forced handover fails due to
handover execution failure, the counter counts the number of
receiving handover execution failure message from low priority
user during the forced handover.
Usage During the forced handover for voice channel assignment in MS
access process, this counter is used to find out the number of
receiving the forced handover failure message due to handover
execution failure.
Measurement When BSC fails to assign voice channel, if forced handover is
Point allowed and there is suitable forced handover target instance,
then the counter increments in the following case: the forcing
handover instance sends the forced handover message to the
forced handover target instance and simultaneously receives the
forced handover failure message which is due to handover
execution failure. The measurement point is B, as shown in
Figure 83.
Unit Times

C901050045
Definition Number of time out for wait resource (assignment forced
handover)
Description When BSC fails to assign voice channel due to no available
resource, it attempts forced handover towards external cell. If
forced handover target instance is found in the cell, the forced
handover is initiated, and when the waiting for forced handover
target instance resource is timeout, the counter counts the
number of timeout due to waiting for resource during the forced
handover.
Usage During the forced handover for voice channel assignment in MS
access process, this counter is used to find out the number of
timeout due to waiting for forced handover target instance
resource.
Measurement When BSC fails to assign voice channel, if forced handover is
Point allowed and there is suitable forced handover target instance,
then the counter increments when the waiting for forced
handover target instance resource is timeout. The measurement
point is B, as shown in Figure 84.

112 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

FIGURE 84 – MEASUREMENT POINT OF NUMBER OF TIMEOUT FOR W AIT


RESOURCE (ASSIGNMENT FORCED HANDOVER)

Unit Times

C901050046
Definition Number of forced release target not found (assignment forced
release)
Description In the assignment flow, after BSC receives the RADIO_APPLY
message, it attempts to assign the voice channel. If there is no
suitable channel and forced release is allowed, then it releases
other channels forcibly, if no forced release target is found in the
cell, then this counter counts the number of times that forced
release target is not found.
Usage During forced release for voice channel assignment, this counter
is used to find out the number of times that forced release
target is not found.
Measurement During an emergency call, BSC fails to assign voice channel. If
Point forced release is allowed but there is no suitable forced release
instance, then the counter increments. The measurement point
is A, as shown in Figure 85.

Confidential and Proprietary Information of ZTE CORPORATION 113


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 85 – MEASUREMENT POINT OF NUMBER OF FORCED RELEASE


T AR G E T N O T FO U N D ( AS S I G N M E NT FO R CE D R E L E AS E )

Unit Times

C901050047
Definition Number of time out for wait resource (assignment forced release)
Description In the assignment flow, after BSC receives the RADIO_APPLY
message, it attempts to assign the voice channel. If there is no
suitable channel and forced release is allowed, then it releases
other channels forcibly. After the forced release is initiated, if
time is out due to waiting for forced release target to release
resource, then this counter counts the number of timeout due to
waiting for resource during the forced release.
Usage During the forced release for voice channel assignment in MS
access process, this counter is used to find out the number of
timeout due to waiting for forced release target instance
resource.
Measurement When BSC fails to assign voice channel, if forced release is
Point allowed and there is suitable forced release target instance, then
the counter increments when the waiting for forced release
target instance resource is timeout. The measurement point is B,
as shown in Figure 86.

114 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - RMM Assignment Measurement

FIGURE 86 – MEASUREMENT POINT OF NUMBER OF TIMEOUT FOR W AIT


RESOURCE (ASSIGNMENT FORCED RELEASE)

Unit Times

C901050048
Definition Number of get before grab released channel (assignment forced
handover)
Description When BSC fails to assign voice channel due to no available
resource, it attempts forced handover towards external cell. If
the handover succeeds in getting the forced handover target
resource, the counter counts the number of preempting the
released channel during the forced handover.
Usage During the forced handover for voice channel assignment in MS
access process, this counter is used to find out the number of
preempting the released channel.
Measurement During the voice channel assignment process for emergency call,
Point if the radio resource request fails and forced handover is allowed,
the forcing handover instance sends the forced handover
message to the forced handover instance. If the message of
resource available is received, then the resource is obtained
successfully, and in this case, the counter increments. The
measurement point is B, as shown in Figure 75.
Unit Times

C901050049
Definition

Confidential and Proprietary Information of ZTE CORPORATION 115


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Number of get before grab released channel(assignment forced


release)
Description BSC fails to assign voice channel due to no available resource, if
it obtains needed channel within specified time after the forced
release is performed, then the forced release is considered
successful, and the counter counts the number of successful
forced releases (emergency service).
Usage This counter is used to find out the number of successful
assignments due to forced release during the MS access process.
Measurement During the voice channel assignment process, if the radio
Point resource request fails and forced release is allowed, the forcing
release instance sends the forced release message to the forced
release instance. If the message of resource available is received,
then the resource is obtained successfully, and in this case, the
counter increments. The measurement point is B, as shown in
Figure 81.
Unit Times

116 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7

Handover Cause
Measurement

This chapter contains detailed information about counters


related to TS measurement.
Handover cause measurement describes frequency of MS
handover due to various causes; it is used for checking cell radio
environment. This chapter contains definitions, usages and
measurement points of counters related to handover cause
measurement.

Overview
Handover cause counter is used for checking MS handover
causes. According to cell radio environment and BSC settings,
handover algorithm judgment module can carry out handover
due to several different handover causes, so as to realize
functions such as optimizing resource usage, improving call
quality and rescuing calls.
The measurement takes cell as the statistics unit.

Handover Cause Measurement


Counter Index
Table 11 lists counters related to handover cause measurement.

TABLE 11 - HANDOVER CAUSE MEASUREMENT COUNTERS

Counter What It Counts


Number of handover attempts due to
C901060001
directed retry
Number of SDCCH handover attempts due
C901060002
to UL received strength

Confidential and Proprietary Information of ZTE CORPORATION 117


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter What It Counts


Number of SDCCH handover attempts due
C901060003
to DL received strength
Number of SDCCH Handover attempt due
C901060004
to UL quality
Number of SDCCH Handover attempt due
C901060005
to DL quality
Number of SDCCH handover attempts due
C901060006
to UL interference
Number of SDCCH handover attempts due
C901060007
to DL interference
Number of SDCCH handover attempts due
C901060008
to C/I RATIO due to good C/I
Number of SDCCH handover attempts due
C901060009
to C/I RATIO due to bad C/I
Number SDCCH of handover attempts due
C901060010
to PBGT
Number of SDCCH handover attempts due
C901060011
to large TA
Number of SDCCH handover attempts due
C901060012
to quick break up of UL
Number of SDCCH handover attempts due
C901060013
to macro-micro switch
Number of SDCCH handover attempts due
C901060014
to MSC request
Number of SDCCH handover attempts due
C901060015
to traffic
Number of SDCCH handover attempts due
C901060016
to large TA and wastage
Number of SDCCH handover attempts due
C901060017
to small TA and wastage
Number of SDCCH Handover attempt due
C901060018 to a preferable electricity level of 3G
adjacent cell
Number SDCCH handover attempts due to
C901060019
forced transfer
Number of SDCCH handover during
C901060020
assignment due to forced transfer
Number of SDCCH handover during
C901060021
handover due to forced transfer
Number of SDCCH handover attempts due
C901060022
to increased TA
Number of SDCCH handover attempts due
C901060023
to TA decrease
Number of SDCCH Handover attempt due
C901060024
to other factors
Number of TCH/F handover attempts due
C901060035
to quick break up of UL
Number of TCH/F handover attempts due
C901060036
to macro-micro switch
Number of TCH/F handover attempts due
C901060037
to MSC request
Number of TCH/F handover attempts due
C901060038
to traffic
Number of TCH/F handover attempts due
C901060039
to large TA and wastage
Number of TCH/F handover attempts due
C901060040
to small TA and wastage

118 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

Counter What It Counts


Number of TCH/F handover attempts due
C901060041 to preferable electricity level in 3G
adjacent cell
Number of TCH/F handover attempts due
C901060042
to forced transfer
Number of TCH/F handover during
C901060043
assignment due to forced transfer
Number of TCH/F handover attempts
C901060044
during handover due to forced transfer
Number of TCH/F handover attempts due
C901060045
to TA increase
Number of TCH/F handover attempts due
C901060046
to TA decrease
Number of TCH/H handover attempts due
C901060058
to quick break up of UL
Number of TCH/H handover attempts due
C901060059
to macro-micro switch
Number of TCH/H handover attempts due
C901060060
to MSC request
Number of TCH/H handover attempts due
C901060061
to traffic
Number of TCH/H handover attempts due
C901060062
to large TA and wastage
Number of TCH/H handover attempts due
C901060063
to small TA and wastage
Number of TCH/H handover attempts due
C901060064 to a preferable electricity level in 3G
adjacent cell
Number of TCH/H handover attempts due
C901060065
to forced transfer
Number of TCH/H handover attempts
C901060066
during assignment due to forced transfer
Number of TCH/H handover attempts
C901060067
during handover due to forced transfer
Number of TCH/H handover attempts
C901060068
during handover due to TA increase
Number of TCH/H handover attempts
C901060069
during handover due to TA decrease
Number of TCH/H handover attempts due
C901060070
to other reasons
Number of TCH/F handover attempts due
C901060071
to CS channel transfer
Number of TCH/H handover attempts due
C901060072
to CS channel transfer
Number of TCH/H handover attempts due
C901060073
to Fragment reorganization
Number of TCH/F handover attempts due
C901060074
to energy conservation
Number of TCH/F handover attempts due
C901060075
to energy conservation
Number of TCH/F handover attempts due
C901060076
to CS channel is forced release
Number of TCH/H handover attempts due
C901060077
to CS channel is forced release
Number of TCH/F handover attempts due
C901060078
to FR to HR during cell busy

Confidential and Proprietary Information of ZTE CORPORATION 119


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901060001
Definition Number of handover attempts due to directed retry
Description During the process of MS requests channel, if radio resource is
congested, then it will attempt to request an available channel
from adjacent cell for this call. This is called direct retry, which is
a kind of handover. This counter counts the number of handover
attempts due to direct retry.
Usage This counter is used to find out MS access process and to check
cell channel utilizing status. If the statistic number counted by
the counter is relative high, then it means the cell does not have
enough radio resource and capacity expansion shall be taken
into account.
Measurement In assignment process, the counter increments if source
Point instance receives message that no available radio resource
replied by target instance, then it chooses cell list successfully
and try to attempt cells in the list. This counter is handover
cause counter and used for finding out cell channel congestion
status, so the counter only counts in the initial judgment. The
measurement point is A, as shown in Figure 87.

FIGURE 87 - DIRECTED RETRY JUDGMENT

Unit Times

C901060002
Definition Number of SDCCH handover attempts due to UL received
strength
Description This counter counts the number of handover attempts due to too
low uplink received strength (on SDCCH).
Usage This counter is used to find out frequency of handover attempts
due to uplink received strength (on SDCCH); high number
means SDCCH uplink signal strength is low.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is uplink signal strength. The
measurement point is A, as shown in Figure 88.

120 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

FIGURE 88 - HANDOVER DECISION

Unit Times

C901060003
Definition Number of SDCCH handover attempts due to DL received
strength
Description This counter counts the number of handover attempts due to too
low downlink received strength (on SDCCH).
Usage This counter is used to find out frequency of handover attempts
due to downlink received strength (on SDCCH); high number
means SDCCH downlink signal strength is low.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is downlink signal strength. The
measurement point is A, as shown in Figure 88.
Unit Times

C901060004
Definition Number of SDCCH Handover attempt due to UL quality.
Description This counter counts the number of handover attempts due to too
bad uplink quality (on SDCCH).
Usage This counter is used to find out frequency of handover attempts
due to uplink quality (on SDCCH); high number means SDCCH
uplink quality is bad.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is uplink quality. The measurement
point is A, as shown in Figure 88.
Unit Times

C901060005
Definition Number of SDCCH Handover attempt due to DL quality.
Description This counter counts the number of handover attempts due to too
bad downlink quality (on SDCCH).

Confidential and Proprietary Information of ZTE CORPORATION 121


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Usage This counter is used to find out frequency of handover attempts


due to downlink quality (on SDCCH); high number means
SDCCH downlink quality is bad.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is downlink quality. The measurement
point is A, as shown in Figure 88.
Unit Times

C901060006
Definition Number of SDCCH handover attempts due to UL interference.
Description This counter counts the number of handover attempts due to too
high uplink interference (on SDCCH).
Usage This counter is used to find out frequency of handover attempts
due to uplink interference (on SDCCH); high number means
SDCCH uplink interference is high.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is uplink interference. The
measurement point is A, as shown in Figure 88.
Unit Times

C901060007
Definition Number of SDCCH handover attempts due to DL interference.
Description This counter counts the number of handover attempts due to too
high downlink interference (on SDCCH).
Usage This counter is used to find out frequency of handover attempts
due to downlink interference (on SDCCH); high number means
SDCCH downlink interference is high.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is downlink interference. The
measurement point is A, as shown in Figure 88.
Unit Times

C901060008
Definition Number of SDCCH handover attempts due to C/I RATIO due to
good C/I
Description

122 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

This counter counts the number of handover attempts due to too


high C/I RATIO (on SDCCH). This handover only happens in sub-
cell configuration and C/I algorithm is used; MS is handed over
from first cell to second cell.
Usage This counter is used to find out frequency of handover attempts
due to too high C/I RATIO (on SDCCH); high number means the
number of MS handover to second cell after MS has been
accessed into first cell due to too high C/I RATIO is high and
second cell absorbs traffic.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is C/I RATIO (on SDCCH) (Good C/I).
The measurement point is A, as shown in Figure 88.
Unit Times

C901060009
Definition Number of SDCCH handover attempts due to C/I RATIO due to
bad C/I
Description This counter counts the number of handover attempts due to too
low C/I RATIO (on SDCCH). This handover only happens in sub-
cell configuration and C/I algorithm is used; MS is handed over
from second cell to first cell.
Usage This counter is used to find out frequency of handover attempts
due to too low C/I RATIO (on SDCCH); high number means
when MS is on the call in second cell, the number of handover to
first cell is high due to too low C/I RATIO; interference in second
cell is high and some measures like TRX power adjustment shall
be done to improve second cell C/I ratio.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is C/I RATIO (on SDCCH) (Bad C/I).
The measurement point is A, as shown in Figure 88.
Unit Times

C901060010
Definition Number SDCCH of handover attempts due to PBGT
Description This counter counts the number of handover attempts due to
PBGT (on SDCCH). If the value of PBGT is higher than 0, then it
means there is an adjacent cell whose radio environment is
better than that of the present cell. If the number that PBGT
value is higher than 0 reaches the threshold, then PBGT
handover will be carried out.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 123


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This counter is used to find out frequency of handover attempts


due to PBGT (on SDCCH); high number means present cell’s
SDCCH signal is worse than that of the adjacent cell.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is PBGT (on SDCCH). The
measurement point is A, as shown in Figure 88.
Unit Times

C901060011
Definition Number of SDCCH handover attempts due to large TA
Description This counter counts the number of handover attempts due to
large TA (on SDCCH). Increase of TA means MS is moving far
away from the cell; when the distance between MS and the cell
reaches a certain value, then handover attempts due to large TA
may occur.
Usage This counter is used to find out frequency of handover attempts
due to large TA (on SDCCH); its value can represent mobility of
the subscriber in the cell in a certain extent.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is large TA (on SDCCH). The
measurement point is A, as shown in Figure 88.
Unit Times

C901060012
Definition Number of SDCCH handover attempts due to quick break up of
UL
Description This counter counts the number of handover attempts due to
uplink break up quickly (on SDCCH). If SDCCH uplink level
decreases abruptly in several continuous measurement reports,
handover attempts due to uplink break up quickly may occur.
Usage This counter is used to find out frequency of handover attempts
due to uplink break up quickly (on SDCCH); its value can
represent stability of the current radio environment in a certain
extent.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is uplink break up quickly (on
SDCCH). The measurement point is A, as shown in Figure 88.
Unit Times

124 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

C901060013
Definition Number of SDCCH handover attempts due to macro-micro
switch.
Description This counter counts the number of handover attempts due to
macro-micro switch (on SDCCH). If adjacent cell level is not
lower than the threshold and the adjacent cell is sub-layer cell,
then handover attempts due to macro-micro switch may occur.
Usage This counter is used to find out frequency of handover attempts
due to macro-micro switch (on SDCCH); its value can represent
the status of micro cell absorbing traffic.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is macro-micro switch (on SDCCH).
The measurement point is A, as shown in Figure 88.
Unit Times

C901060014
Definition Number of SDCCH handover attempts due to MSC request.
Description This counter counts the number of handover attempts due to
MSC request (on SDCCH). Handover is originated by MSC, some
calls are handed over from the present cell to target cell for
alleviating the present cell traffic load.
Usage This counter is used to find out frequency of handover attempts
due to MSC request (on SDCCH); its value can represent the
status that MSC adjusts the present cell traffic.
Measurement BSC carries out handover judgment after receiving
Point “HO_ENQUIRY” message sent by MSC; the counter increments if
judgment result is yes. The measurement point is A, as shown in
Figure 89.

FIGURE 89 – HO_ENQUIRY HANDOVER

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 125


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901060015
Definition Number of SDCCH handover attempts due to traffic.
Description This counter counts the number of handover attempts due to
traffic (on SDCCH). Handover is originated by BSC, some calls
are handed over from the present cell to target cell for
alleviating the present cell traffic load.
Usage This counter is used to find out frequency of handover attempts
due to traffic (on SDCCH); its value can represent the status
that BSC adjusts the present cell traffic.
Measurement BSC carries out handover judgment after receiving SDCCH traffic
Point alarm, the counter increments if judgment result is yes. The
measurement point is A, as shown in Figure 90. DBS, UMC and
RANCS are all instances of BSC and they take part in handover
due to traffic.

FIGURE 90 – TRAFFIC HANDOVER

Unit Times

C901060016
Definition Number of SDCCH handover attempts due to large TA and
wastage.
Description This counter counts the number of handover attempts due to
large TA and wastage (on SDCCH). This handover only happens
in sub-cell configuration and TA&PassLoss algorithm is used;
when both TA and PassLoss are higher than set threshold, MS is
handed over from second cell to first cell.
Usage This counter is used to find out frequency of handover attempts
due to large TA and wastage (on SDCCH); its value can
represent the mobility of subscriber among sub-cells in the cell.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is large TA and wastage (on SDCCH).
The measurement point is A, as shown in Figure 88.

126 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

Unit Times

C901060017
Definition Number of SDCCH handover attempts due to small TA and
wastage.
Description This counter counts the number of handover attempts due to
small TA and wastage (on SDCCH). This handover only happens
in sub-cell configuration and TA&PassLoss algorithm is used;
when both TA and PassLoss are lower than set threshold, MS is
handed over from first cell to second cell.
Usage This counter is used to find out frequency of handover attempts
due to small TA and wastage (on SDCCH); its value can
represent the mobility of subscriber among sub-cells in the cell.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is small TA and wastage (on SDCCH).
The measurement point is A, as shown in Figure 88.
Unit Times

C901060018
Definition Number of SDCCH handover attempt due to a preferable
electricity level of FDD adjacent cell.
Description This counter counts the number of handover attempts due to a
good standard level in FDD adjacent cell (on SDCCH).
Usage This counter is used to find out frequency of handover attempts
due to a good standard level in FDD adjacent cell (on SDCCH);
its value can represent status that 3G network absorbs traffic.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is good standard level in FDD
adjacent cell (on SDCCH). The measurement point is A, as
shown in Figure 88.
Unit Times

C901060019
Definition Number SDCCH handover attempts due to forced transfer.
Description This counter counts the number of forced transfer handover
attempts (on SDCCH). If the TCH utilizing rate of the present cell
reaches a set percentage of the threshold, BSC will try to
handover subscriber whose path loss and TA are small from the

Confidential and Proprietary Information of ZTE CORPORATION 127


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

present cell to some set cells. This kind of handover is called


forced transfer handover.
Usage This counter is used to find out frequency of forced transfer
handover attempts (on SDCCH); its value can represent the
present cell’s channel utilizing status and traffic sharing status.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is forced transfer handover attempts
(on SDCCH). The measurement point is A, as shown in Figure 88.
Unit Times

C901060020
Definition Number of SDCCH handover during assignment due to forced
transfer.
Description This counter counts the number of forced handovers during
assignment (on SDCCH). If all TCH of the present cell are
occupied and MS priority is high enough, BSC will try to
handover services whose priority are low from the present cell to
adjacent cells. This kind of handover is called forced handover.
Forced handover and forced release are two forms of occupation.
Usage This counter is used to find out frequency of forced handovers
during assignment (on SDCCH); its value can represent the
present cell’s TCH utilizing status and traffic sharing status.
Measurement BSC has no available TCH to allocate during the assignment
Point process and it carries out forced handover judgment; the
counter increments if judgment result is yes and the channel
type of forced handover instance is SDCCH. The measurement
point is A, as shown in Figure 91.

FIGURE 91 – FORCED HANDOVER JUDGMENT

Unit Times

128 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

C901060021
Definition Number of SDCCH handover during handover due to forced
transfer.
Description This counter counts the number of forced handovers during
handover (on SDCCH).
Usage This counter is used to find out frequency of forced handovers
during handover (on SDCCH); its value can represent the
present cell’s TCH utilizing status and traffic sharing status.
Measurement BSC has no available TCH to allocate during the handover
Point process and it carries out forced handover judgment; the
counter increments if judgment result is yes and the channel
type of forced handover instance is SDCCH. The measurement
point is A, as shown in Figure 91.
Unit Times

C901060022
Definition Number of SDCCH handover attempts due to increased TA.
Description This counter counts the number of handover attempts due to
increased TA (on SDCCH). This handover only happens in
expanding cell configuration, present BSC version does not use
expanded cell and expanded TRX configuration any more after
being introduced the concept of sub-cell. This counter is equal to
the counter that counts the number of MS handover from second
cell to first cell during sub-cell configuration.
Usage This counter is used to find out frequency of MS handover from
second cell to first cell in sub-cell.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover is from second cell to first cell. The
measurement point is A, as shown in Figure 88.
Unit Times

C901060023
Definition Number of SDCCH handover attempts due to TA decrease.
Description This counter counts the number of handover attempts due to
decreased TA (on SDCCH). This handover only happens in
expanding cell configuration, present BSC version does not use
expanded cell and expanded TRX configuration any more after
being introduced the concept of sub-cell. This counter is equal to
the counter that counts the number of MS handover from first
cell to second cell during sub-cell configuration.

Confidential and Proprietary Information of ZTE CORPORATION 129


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Usage This counter is used to find out frequency of MS handover from


first cell to second cell in sub-cell.
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover is from first cell to second cell. The
measurement point is A, as shown in Figure 88.
Unit Times

C901060024
Definition Number of SDCCH Handover attempt due to other factors.
Description This counter counts the number of handover attempts due to
any other reason except reasons mentioned above (on SDCCH).
Usage This counter is used to find out frequency of handover attempts
due to any other reason (on SDCCH).
Measurement BSC carries out handover judgment after receiving SDDCH
Point measurement report; the counter increments if judgment result
is yes and handover cause is any other reason. The
measurement point is A, as shown in Figure 88.
Unit Times

C901060035
Definition Number of TCH/F handover attempts due to quick break up of
UL.
Description This counter counts the number of handover attempts due to
uplink break up quickly (on TCH/F). If TCH/F uplink level
decreases abruptly in several continuous measurement reports,
handover attempts due to uplink break up quickly may occur.
Usage This counter is used to find out frequency of handover attempts
due to uplink break up quickly (on TCH/F); its value can
represent stability of the current radio environment in a certain
extent.
Measurement BSC carries out handover judgment after receiving TCH/F
Point measurement report; the counter increments if judgment result
is yes and handover cause is uplink break up quickly (on TCH/F).
The measurement point is A, as shown in Figure 88.
Unit Times

C901060036
Definition Number of TCH/F handover attempts due to macro-micro switch.

130 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

Description This counter counts the number of handover attempts due to


macro-micro switch (on TCH/F). If adjacent cell level is not
lower than the threshold and the adjacent cell is sub-layer cell,
then handover attempts due to macro-micro switch may occur.
Usage This counter is used to find out frequency of handover attempts
due to macro-micro switch (on TCH/F); its value can represent
the status of micro cell absorbing traffic.
Measurement BSC carries out handover judgment after receiving TCH/F
Point measurement report; the counter increments if judgment result
is yes and handover cause is macro-micro switch (on TCH/F).
The measurement point is A, as shown in Figure 88.
Unit Times

C901060037
Definition Number of TCH/F handover attempts due to MSC request.
Description This counter counts the number of handover attempts due to
MSC request (on TCH/F). Handover is originated by MSC, some
calls are handed over from the present cell to target cell for
alleviating the present cell traffic load.
Usage This counter is used to find out frequency of handover attempts
due to MSC request (on TCH/F); its value can represent the
status that MSC adjusts the present cell traffic.
Measurement BSC carries out handover judgment after receiving
Point “HO_ENQUIRY” message sent by MSC; the counter increments if
judgment result is yes. The measurement point is A, as shown in
Figure 89.
Unit Times

C901060038
Definition Number of TCH/F handover attempts due to traffic.
Description This counter counts the number of handover attempts due to
traffic (on TCH/F). Handover is originated by BSC, some calls are
handed over from the present cell to target cell for alleviating
the present cell traffic load.
Usage This counter is used to find out frequency of handover attempts
due to traffic (on TCH/F); its value can represent the status that
BSC adjusts the present cell traffic.
Measurement BSC carries out handover judgment after receiving TCH/F traffic
Point alarm, the counter increments if judgment result is yes. The
measurement point is A, as shown in Figure 90.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 131


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901060039
Definition Number of TCH/F handover attempts due to large TA and
wastage.
Description This counter counts the number of handover attempts due to
large TA and wastage (on TCH/F). This handover only happens
in sub-cell configuration and TA&PassLoss algorithm is used;
when both TA and PassLoss are higher than set threshold, MS is
handed over from second cell to first cell.
Usage This counter is used to find out frequency of handover attempts
due to large TA and wastage (on TCH/F); its value can represent
the mobility of subscriber among sub-cells in the cell.
Measurement BSC carries out handover judgment after receiving TCH/F
Point measurement report; the counter increments if judgment result
is yes and handover cause is large TA and wastage (on TCH/F).
The measurement point is A, as shown in Figure 88.
Unit Times

C901060040
Definition Number of TCH/F handover attempts due to small TA and
wastage.
Description This counter counts the number of handover attempts due to
small TA and wastage (on TCH/F). This handover only happens
in sub-cell configuration and TA&PassLoss algorithm is used;
when both TA and PassLoss are lower than set threshold, MS is
handed over from first cell to second cell.
Usage This counter is used to find out frequency of handover attempts
due to small TA and wastage (on TCH/F); its value can represent
the mobility of subscriber among sub-cells in the cell.
Measurement BSC carries out handover judgment after receiving TCH/F
Point measurement report; the counter increments if judgment result
is yes and handover cause is small TA and wastage (on TCH/F).
The measurement point is A, as shown in Figure 88.
Unit Times

C901060041
Definition Number of TCH/F handover attempts due to preferable electricity
level in 3G adjacent cell.
Description This counter counts the number of handover attempts due to a
good standard level in 3G adjacent cell (on TCH/F).
Usage

132 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

This counter is used to find out frequency of handover attempts


due to a good standard level in 3G adjacent cell (on TCH/F); its
value can represent status that 3G network absorbs traffic.
Measurement BSC carries out handover judgment after receiving TCH/F
Point measurement report; the counter increments if judgment result
is yes and handover cause is good standard level in 3G adjacent
cell (on TCH/F). The measurement point is A, as shown in Figure
88.
Unit Times

C901060042
Definition Number of TCH/F handover attempts due to forced transfer.
Description This counter counts the number of forced transfer handover
attempts (on TCH/F). If the TCH utilizing rate of the present cell
reaches a set percentage of the threshold, BSC will try to
handover subscriber whose path loss and TA are small from the
present cell to some set cells. This kind of handover is called
forced transfer handover.
Usage This counter is used to find out frequency of forced transfer
handover attempts (on TCH/F); its value can represent the
present cell’s channel utilizing status and traffic sharing status.
Measurement BSC carries out handover judgment after receiving TCH/F
Point measurement report; the counter increments if judgment result
is yes and handover cause is forced transfer handover attempts
(on TCH/F). The measurement point is A, as shown in Figure 88.
Unit Times

C901060043
Definition Number of TCH/F handover during assignment due to forced
transfer.
Description This counter counts the number of forced handovers during
assignment (on TCH/F). If all TCH of the present cell are
occupied and MS priority is high enough, BSC will try to
handover services whose priority are low from the present cell to
adjacent cells. This kind of handover is called forced handover.
Usage This counter is used to find out frequency of forced handovers
during assignment (on TCH/F); its value can represent the
present cell’s TCH utilizing status and traffic sharing status.
Measurement BSC has no available TCH to allocate during the assignment
Point process and it carries out forced handover judgment; the
counter increments if judgment result is yes and the channel
type of forced handover instance is TCH/F. The measurement
point is A, as shown in Figure 91.

Confidential and Proprietary Information of ZTE CORPORATION 133


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Unit Times

C901060044
Definition Number of TCH/F handover attempts during handover due to
forced transfer.
Description This counter counts the number of forced handovers during
handover (on TCH/F).
Usage This counter is used to find out frequency of forced handovers
during handover (on TCH/F); its value can represent the present
cell’s TCH utilizing status and traffic sharing status.
Measurement BSC has no available TCH to allocate during the handover
Point process and it carries out forced handover judgment; the
counter increments if judgment result is yes and the channel
type of forced handover instance is TCH/F. The measurement
point is A, as shown in Figure 91.
Unit Times

C901060045
Definition Number of TCH/F handover attempts due to TA increase.
Description This counter counts the number of handover attempts due to
increased TA (on TCH/F). This handover only happens in
expanding cell configuration, present BSC version does not use
expanded cell and expanded TRX configuration any more after
being introduced the concept of sub-cell. This counter is equal to
the counter that counts the number of MS handover from second
cell to first cell during sub-cell configuration.
Usage This counter is used to find out frequency of MS handover from
second cell to first cell in sub-cell.
Measurement BSC carries out handover judgment after receiving TCH/F
Point measurement report; the counter increments if judgment result
is yes and handover is from second cell to first cell. The
measurement point is A, as shown in Figure 88.
Unit Times

C901060046
Definition Number of TCH/F handover attempts due to TA decrease.
Description This counter counts the number of handover attempts due to
decreased TA (on TCH/F). This handover only happens in
expanding cell configuration, present BSC version does not use
expanded cell and expanded TRX configuration any more after

134 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

being introduced the concept of sub-cell. This counter is equal to


the counter that counts the number of MS handover from first
cell to second cell during sub-cell configuration.
Usage This counter is used to find out frequency of MS handover from
first cell to second cell in sub-cell.
Measurement BSC carries out handover judgment after receiving TCH/F
Point measurement report; the counter increments if judgment result
is yes and handover is from first cell to second cell. The
measurement point is A, as shown in Figure 88.
Unit Times

C901060058
Definition Number of TCH/H handover attempts due to quick break up of
UL.
Description This counter counts the number of handover attempts due to
uplink break up quickly (on TCH/H). If TCH/H uplink level
decreases abruptly in several continuous measurement reports,
handover attempts due to uplink break up quickly may occur.
Usage This counter is used to find out frequency of handover attempts
due to uplink break up quickly (on TCH/H); its value can
represent stability of the current radio environment in a certain
extent.
Measurement BSC carries out handover judgment after receiving TCH/H
Point measurement report; the counter increments if judgment result
is yes and handover cause is uplink break up quickly (on TCH/H).
The measurement point is A, as shown in Figure 88.
Unit Times

C901060059
Definition Number of TCH/H handover attempts due to macro-micro switch.
Description This counter counts the number of handover attempts due to
macro-micro switch (on TCH/H). If adjacent cell level is not
lower than the threshold and the adjacent cell is sub-layer cell,
then handover attempts due to macro-micro switch may occur.
Usage This counter is used to find out frequency of handover attempts
due to macro-micro switch (on TCH/H); its value can represent
the status of micro cell absorbing traffic.
Measurement BSC carries out handover judgment after receiving TCH/H
Point measurement report; the counter increments if judgment result
is yes and handover cause is macro-micro switch (on TCH/H).
The measurement point is A, as shown in Figure 88.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 135


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901060060
Definition Number of TCH/H handover attempts due to MSC request.
Description This counter counts the number of handover attempts due to
MSC request (on TCH/H). Handover is originated by MSC, some
calls are handed over from the present cell to target cell for
alleviating the present cell traffic load.
Usage This counter is used to find out frequency of handover attempts
due to MSC request (on TCH/H); its value can represent the
status that MSC adjusts the present cell traffic.
Measurement BSC carries out handover judgment after receiving
Point “HO_ENQUIRY” message sent by MSC; the counter increments if
judgment result is yes. The measurement point is A, as shown in
Figure 89.
Unit Times

C901060061
Definition Number of TCH/H handover attempts due to traffic.
Description This counter counts the number of handover attempts due to
traffic (on TCH/H). Handover is originated by BSC, some calls
are handed over from the present cell to target cell for
alleviating the present cell traffic load.
Usage This counter is used to find out frequency of handover attempts
due to traffic (on TCH/H); its value can represent the status that
BSC adjusts the present cell traffic.
Measurement BSC carries out handover judgment after receiving TCH/H traffic
Point alarm, the counter increments if judgment result is yes. The
measurement point is A, as shown in Figure 90.
Unit Times

C901060062
Definition Number of TCH/H handover attempts due to large TA and
wastage.
Description This counter counts the number of handover attempts due to
large TA and wastage (on TCH/H). This handover only happens
in sub-cell configuration and TA&PassLoss algorithm is used;
when both TA and PassLoss are higher than set threshold, MS is
handed over from second cell to first cell.
Usage This counter is used to find out frequency of handover attempts
due to large TA and wastage (on TCH/H); its value can represent
the mobility of subscriber among sub-cells in the cell.

136 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

Measurement BSC carries out handover judgment after receiving TCH/H


Point measurement report; the counter increments if judgment result
is yes and handover cause is large TA and wastage (on TCH/H).
The measurement point is A, as shown in Figure 88.
Unit Times

C901060063
Definition Number of TCH/H handover attempts due to small TA and
wastage.
Description This counter counts the number of handover attempts due to
small TA and wastage (on TCH/H). This handover only happens
in sub-cell configuration and TA&PassLoss algorithm is used;
when both TA and PassLoss are lower than set threshold, MS is
handed over from first cell to second cell.
Usage This counter is used to find out frequency of handover attempts
due to small TA and wastage (on TCH/H); its value can
represent the mobility of subscriber among sub-cells in the cell.
Measurement BSC carries out handover judgment after receiving TCH/H
Point measurement report; the counter increments if judgment result
is yes and handover cause is small TA and wastage (on TCH/H).
The measurement point is A, as shown in Figure 88.
Unit Times

C901060064
Definition Number of TCH/H handover attempts due to a preferable
electricity level in 3G adjacent cell.
Description This counter counts the number of handover attempts due to a
good standard level in 3G adjacent cell (on TCH/H).
Usage This counter is used to find out frequency of handover attempts
due to a good standard level in 3G adjacent cell (on TCH/H); its
value can represent status that 3G network absorbs traffic.
Measurement BSC carries out handover judgment after receiving TCH/H
Point measurement report; the counter increments if judgment result
is yes and handover cause is good standard level in 3G adjacent
cell (on TCH/H). The measurement point is A, as shown in Figure
88.
Unit Times

C901060065
Definition Number of TCH/H handover attempts due to forced transfer.

Confidential and Proprietary Information of ZTE CORPORATION 137


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of forced transfer handover


attempts (on TCH/H). If the TCH utilizing rate of the present cell
reaches a set percentage of the threshold, BSC will try to
handover subscriber whose path loss and TA are small from the
present cell to some set cells. This kind of handover is called
forced transfer handover.
Usage This counter is used to find out frequency of forced transfer
handover attempts (on TCH/H); its value can represent the
present cell’s channel utilizing status and traffic sharing status.
Measurement BSC carries out handover judgment after receiving TCH/H
Point measurement report; the counter increments if judgment result
is yes and handover cause is forced transfer handover attempts
(on TCH/H). The measurement point is A, as shown in Figure 88.
Unit Times

C901060066
Definition Number of TCH/H handover attempts during assignment due to
forced transfer.
Description This counter counts the number of forced handovers during
assignment (on TCH/H). If all TCH of the present cell are
occupied and MS priority is high enough, BSC will try to
handover services whose priority are low from the present cell to
adjacent cells. This kind of handover is called forced handover.
Usage This counter is used to find out frequency of forced handovers
during assignment (on TCH/H); its value can represent the
present cell’s TCH utilizing status and traffic sharing status.
Measurement BSC has no available TCH to allocate during the assignment
Point process and it carries out forced handover judgment; the
counter increments if judgment result is yes and the channel
type of forced handover instance is TCH/H. The measurement
point is A, as shown in Figure 91.
Unit Times

C901060067
Definition Number of TCH/H handover attempts during handover due to
forced transfer.
Description This counter counts the number of forced handovers during
handover (on TCH/H).
Usage This counter is used to find out frequency of forced handovers
during handover (on TCH/H); its value can represent the present
cell’s TCH utilizing status and traffic sharing status.
Measurement BSC has no available TCH to allocate during the handover
Point process and it carries out forced handover judgment; the

138 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

counter increments if judgment result is yes and the channel


type of forced handover instance is TCH/H. The measurement
point is A, as shown in Figure 91.
Unit Times

C901060068
Definition Number of TCH/H handover attempts during handover due to TA
increase.
Description This counter counts the number of handover attempts due to
increased TA (on TCH/H). This handover only happens in
expanding cell configuration, present BSC version does not use
expanded cell and expanded TRX configuration any more after
being introduced the concept of sub-cell. This counter is equal to
the counter that counts the number of MS handover from second
cell to first cell during sub-cell configuration.
Usage This counter is used to find out frequency of MS handover from
second cell to first cell in sub-cell.
Measurement BSC carries out handover judgment after receiving TCH/H
Point measurement report; the counter increments if judgment result
is yes and handover is from second cell to first cell. The
measurement point is A, as shown in Figure 88.
Unit Times

C901060069
Definition Number of TCH/H handover attempts during handover due to TA
decrease.
Description This counter counts the number of handover attempts due to
decreased TA (on TCH/H). This handover only happens in
expanding cell configuration, present BSC version does not use
expanded cell and expanded TRX configuration any more after
being introduced the concept of sub-cell. This counter is equal to
the counter that counts the number of MS handover from first
cell to second cell during sub-cell configuration.
Usage This counter is used to find out frequency of MS handover from
first cell to second cell in sub-cell.
Measurement BSC carries out handover judgment after receiving TCH/H
Point measurement report; the counter increments if judgment result
is yes and handover is from first cell to second cell. The
measurement point is A, as shown in Figure 88.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 139


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901060070
Definition Number of TCH/H handover attempts due to other reasons
Description This counter counts the number of handover attempts due to
other reasons except for those reasons mentioned above.
Usage This counter is used to find out handover frequency due to other
reasons.
Measurement BSC carries out handover judgment after receiving TCH/H
Point measurement report; the counter increments if judgment result
is yes and handover is caused by other reasons. The
measurement point is A, as shown in Figure 88.
Unit Times

C901060071
Definition Number of TCH/F handover attempts due to CS channel transfer
Description This counter counts the number of handover due to CS channel
transfer for continuity of available PS channel on TCH/F. the
handover caused by this reason is intra-cell handover.
Usage This counter is used to find out handover frequency due to CS
channel transfer on TCH/F.
Measurement During call service, due to other call services released, CS
Point service channel transfer is issued to do intra-cell handover. The
service occupying middle timeslot can be migrated to edge
timeslot, providing available sustainable channels for PS. This
counter increments if the channel type of instance is TCH/F. The
measurement point is A, as shown in Figure 92.

FIGURE 92 - CS CHANNEL TRANSFER HANDOVER

Unit Times

C901060072
Definition Number of TCH/H handover attempts due to CS channel transfer

140 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

Description This counter counts the number of handover due to CS channel


transfer by BSC, which is useful for continuity of available PS
channel on TCH/H. This may lead to intra-cell handover.
Usage This counter is used to find out handover frequency due to CS
channel handover on TCH/H by BSC.
Measurement During call service, due to other call service released, CS service
Point channel transfer is issued to do intra-cell handover. The service
occupying middle timeslot service can be migrated to edge
timeslot, providing available continual channel. This counter
increments if channel type for handover instance is TCH/H. The
measurement point is A, as shown in Figure 92.
Unit Times

C901060073
Definition Number of TCH/H handover attempts due to Fragment
reorganization
Description BSC carries out fragment reorganization for one of two half-rate
serive occupying different timeslot, combining these two half-
rate service into one timeslot by intra-cell handover, so one full-
rate channel can be idle. This couner counts the number of
handover attempts due to fragment reorganization.
Usage This counter is used to find out handover frequency due to
combining two half-rate channel on TCH/H by BSC.
Measurement New call service instance doesn’t apply for full-rate channel, or
Point due to other call service released, fragment reorganization is
issued to do intra-cell handover. It will combine two half-rate
service into one timeslot. The couner increments while one full-
rate channel is idle. The measurement point is A, as shown in
Figure 92.
Unit Times

C901060074
Definition Number of TCH/F handover attempts due to energy conservation
Description Carrier is powered off intelligently by energy conservation, BSC
migrates the service on the carrier to other carrier by intra-cell
handover. This counter counts the number of handover attempts
due to energy conservation on TCH/F by BSC.
Usage This counter is used to find out handover frequency due to
energy conservation on TCH/F by BSC.
Measurement Carrier is intelligently powered off by energy conservation, do
Point intra-cell handover for the call service on the carrier to be
powered off and migrated to other carrier. If channel type of

Confidential and Proprietary Information of ZTE CORPORATION 141


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

handover instance is TCH/F, this counter increments. The


measurement point is A, as shown in Figure 92.
Unit Times

C901060075
Definition Number of TCH/F handover attempts due to energy conservation
Description Carrier is powered off intelligently by energy conservation, BSC
migrates the service on the carrier to other carrier by intra-cell
handover. This counter counts the number of handover attempts
due to energy conservation on TCH/H by BSC.
Usage This counter is used to find out handover frequency due to
energy conservation on TCH/H by BSC.
Measurement Carrier is intelligently powered off by energy conservation, do
Point intra-cell handover for the call service on the carrier to be
powered off and migrated to other carrier. If channel type of
handover instance is TCH/H, this counter increments. The
measurement point is A, as shown in Figure 92.
Unit Times

C901060076
Definition Number of TCH/F handover attempts due to CS channel is forced
release
Description Due to unsuccessful PS channel application, BSC does intra-cell
handover transfer for CS instance that occupies PDTCH channel
by BSC, the available PS channel will be used by PS service. This
counter counts the number of handover attempts due to CS
channel forcedly released.
Usage This counter is used to find out handover frequency due to CS
service seizured by PS on TCH/F.
Measurement After PS service channel application is failed, do intra-cell
Point handover for CS service that occupies PDTCH channel, available
PS channel is used by PS service. If channel type of CS handover
instance is TCH/F, this counter increments. The measurement
point is A, as shown in Figure 92.
Unit Times

C901060077
Definition Number of TCH/H handover attempts due to CS channel is
forced release
Description

142 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Handover Cause Measurement

Due to unsuccessful PS channel application, BSC does intra-cell


handover transfer for CS instance that occupies PDTCH channel,
the available PS channel will be used by PS service. This counter
counts the number of handover attempts due to CS channel
forcedly released on TCH/H by BSC.
Usage This counter is used to find out handover frequency due to CS
service seizured by PS on TCH/H.
Measurement After PS service channel application is failed, do intra-cell
Point handover for CS service that occupies PDTCH channel, available
PS channel is used by PS service. If channel type of CS handover
instance is TCH/H, this counter increments. The measurement
point is A, as shown in Figure 92.
Unit Times

C901060078
Definition Number of TCH/F handover attempts due to FR to HR during cell
busy
Description This counter counts the number of handover attempts due to FR
transferred to HR on busy, it can connect more services.
Usage This counter is used to find out handover frequency due to FR
transferred to HR on busy.
Measurement N/A.
Point

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 143


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

144 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8

RMM Call Drop


Measurement

This chapter contains detailed information about counters


related to data flow measurement.
RMM call drop measurement measures the number of call drops
on various channels and services, as well as data related to call
drop cause in signaling flow; it is used to find out network
operation status, evaluate network performance, adjust network
parameter, etc. This chapter introduces definitions, usages and
measurement points of counters in RMM call drop measurement.

Overview
Channels that take part in the measurement statistic include
SDCCH, TCH/F and TCH/H. Service types include signaling, voice
and data. Counted call drop causes include RMM losses contact
with SMM, BTS radio link failure, LAPD link failure, OMCR forced
release, forced release by other calls, handover failure, as well as
other failure.
The measurement takes cell as the statistics unit.

RMM Call Drop Measurement


Counter Index
Table 12 lists counters related to RMM call drop measurement.

TABLE 12 - RMM CALL DROP MEASUREMENT COUNTERS

Counter What It Counts


Number of SDCCH drops due to loss of
C901070001
contact with RANA

Confidential and Proprietary Information of ZTE CORPORATION 145


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter What It Counts


Number of SDCCH drops due to radio link
C901070002
failure
Number of SDCCH drops due to LAPD link
C901070003
failure
Number of SDCCH drops due to OMC-R
C901070004
forced release
Number of SDCCH drops due to forced
C901070005
release by other calls
Number of SDCCH drops due to other
C901070007
failure
Number of signaling TCH/F drops due to
C901070008
loss of contact with RANA
Number of signaling TCH/F drops due to
C901070009
radio link failure
Number of signaling TCH/F drops due to
C901070010
LAPD link failure
Number of signaling TCH/F drops due to
C901070011
OMC-R forced release
Number of signaling TCH/F drops due to
C901070012
forced release by other calls
Number of signaling TCH/F drops due to
C901070014
other failure
Number of voice TCH/F drops due to loss
C901070015
of contact with RANA
Number of voice TCH/F drops due to LAPD
C901070017
link failure
Number of voice TCH/F drops due to OMC-
C901070018
R forced release
Number of voice TCH/F drops due to
C901070019
forced release by other calls
Number of voice TCH/F drops due to other
C901070021
failure
Number of data TCH/F drops due to loss of
C901070022
contact with RANA
Number of data TCH/F drops due to radio
C901070023
link failure
Number of data TCH/F drops due to LAPD
C901070024
link failure
Number of data TCH/F drops due to OMC-
C901070025
R forced release
Number of data TCH/F drops due to forced
C901070026
release by other calls
Number of data TCH/F drops due to other
C901070028
failure
C901070029 Number of signaling TCH/H drops due to

146 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

Counter What It Counts


loss of contact with RANA
Number of signaling TCH/H drops due to
C901070030
radio link failure
Number of signaling TCH/H drops due to
C901070031
LAPD link failure
Number of signaling TCH/H drops due to
C901070032
OMC-R forced release
Number of signaling TCH/H drops due to
C901070033
forced release by other calls
Number of signaling TCH/H drops due to
C901070035
other failure
Number of voice TCH/H drops due to loss
C901070036
of contact with RANA
Number of voice TCH/H drops due to LAPD
C901070038
link failure
Number of voice TCH/H drops due to OMC-
C901070039
R forced release
Number of voice TCH/H drops due to
C901070040
forced release by other calls
Number of voice TCH/H drops due to other
C901070042
failure
Number of data TCH/H drops due to loss
C901070043
of contact with RANA
Number of data TCH/H drops due to radio
C901070044
link failure
Number of data TCH/H drops due to LAPD
C901070045
link failure
Number of data TCH/H drops due to OMC-
C901070046
R forced release
Number of data TCH/H drops due to forced
C901070047
release by other calls
Number of data TCH/H drops due to other
C901070049
failure
C901070053 Number of SDCCH link failures
C901070054 Number of TCH/F link failures
C901070055 Number of TCH/H link failures
Number of RANA link releases due to other
C901070056
cause on SDCCH
Number of RANA link releases due to other
C901070057
cause on TCH/F
Number of RANA link releases due to other
C901070058
cause on TCH/H
C901070059 Number of SDCCH short messages drops
C901070060 Number of TCH/F short messages drops

Confidential and Proprietary Information of ZTE CORPORATION 147


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter What It Counts


C901070061 Number of TCH/H short messages drops
Number of TCH/F drops due to CS channel
C901070062
is forced release by PS
Number of TCH/H drops due to CS channel
C901070063
is forced release by PS
Number of SDCCH drops due to eMLPP
C901070064
forced handover
Number of signaling TCH/F drops due to
C901070065
eMLPP forced handover
Number of voice TCH/F drops due to
C901070066
eMLPP forced handover
Number of data TCH/F drops due to eMLPP
C901070067
forced handover
Number of sigaling TCH/H drops due to
C901070068
eMLPP forced handover
Number of voice TCH/H drops due to
C901070069
eMLPP forced handover
Number of data TCH/H drops due to eMLPP
C901070070
forced handover
C901070071 Bad quality of UL receiving (On SDCCH)
C901070072 Bad quality of DL receiving (On SDCCH)
C901070073 Lower electrical level of UL (On SDCCH)
C901070074 Lower electrical level of DL (On SDCCH)
Number of signaling drops due to TA too
C901070075
far (On SDCCH)
C901070076 Reasons of the other radios (On SDCCH)
C901070077 Bad quality of UL receiving (On TCH/F)
C901070078 Bad quality of DL receiving (On TCH/F)
C901070079 Lower electrical level of UL (On TCH/F)
C901070080 Lower electrical level of DL (On TCH/F)
Number of signaling drops due to TA too
C901070081
far (On TCH/F)
C901070082 Reasons of the other radios (On TCH/F)
C901070083 Bad quality of UL receiving (On TCH/H)
C901070084 Bad quality of DL receiving (On TCH/H)
C901070085 Lower electrical level of UL (On TCH/H)
C901070086 Lower electrical level of DL (On TCH/H)
Number of signaling drops due to TA too
C901070087
far (On TCH/H)
C901070088 Reasons of the other radios (On TCH/H)

148 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

C901070001
Definition Number of SDCCH drops due to loss of contact with RANA
Description This counter counts the number of failures due to loss of contact
with SMM. The counter increments if the phenomenon that call
drops after MS has obtained SDCCH is caused by the loss of
contact with SMM.
Usage This counter is used to find out the frequency of failures due to
loss of contact with SMM.
Measurement The counter counts the number of failures due to loss of contact
Point with SMM in the following two cases:
„ After link between RANCS and RANA has been established on
SDCCH, heartbeat handshake is carried out. If RANCS or
RANA can not receive heartbeat message from each other
during 4 unit time, then it is regarded as link failure and the
counter increments; meanwhile, BSC release the channel and
instance, the measurement point is A1, as shown in Figure
93.

FIGURE 93 – CALL DROP DUE TO A-INTERFACE FAILURE IN IMMEDIATE


ASSIGNMENT PROCESS

„ RANCS forwards “EST_IND” message to RANA after receiving


it on SDCCH; if no link establishment message on A-interface
from RANA is received, the counter increments; meanwhile,
BSC release the channel and instance, the measurement
point is A2, as shown in Figure 93.
Unit Times

C901070002
Definition Number of SDCCH drops due to radio link failure
Description This counter counts the number of call drop due to radio link
failures (On SDCCH). The counter increments if the phenomenon
that call drops after MS has obtained SDCCH is caused by radio
link failures.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 149


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This counter is used to find out the frequency of call drop due to
radio link failures (On SDCCH).
Measurement The counter increments when BSC receives “CONNectiOn
Point FAILure INDicatiOn” message on Abis interface on SDCCH. The
measurement point is A, as shown in Figure 94.

FIGURE 94 – CALL DROP DUE TO RADIO LINK FAILURE IN IMMEDIATE


ASSIGNMENT PROCESS

Unit Times

C901070003
Definition Number of SDCCH drops due to LAPD link failure
Description This counter counts the number of call drop due to LAPD link
failures (On SDCCH). The counter increments if the phenomenon
that call drops after MS has obtained SDCCH is caused by LAPD
link failures.
Usage This counter is used to find out the frequency of call drop due to
LAPD link failures (On SDCCH).
Measurement The counter increments when BSC receives “DLREL_IND”
Point message from LAPD on SDCCH. The measurement point is A, as
shown in Figure 95.

150 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

FIGURE 95 – CALL DROP DUE TO LAPD LINK FAILURE IN IMMEDIATE


ASSIGNMENT PROCESS

Unit Times

C901070004
Definition Number of SDCCH drops due to OMC-R forced release
Description This counter counts the number of call drop due to OMC-R
forced releases (on SDCCH). The counter increments if the
phenomenon that call drops after MS has obtained SDCCH is
caused by OMC-R forced releases.
Usage This counter is used to find out the frequency of call drop due to
OMC-R forced releases (on SDCCH).
Measurement The counter increments when BSC receives OMC-R forced
Point release message from database on SDCCH. The measurement
point is A, as shown in Figure 96.

FIGURE 96 – CALL DROP DUE TO OMC-R FORCED RELEASE IN IMMEDIATE


ASSIGNMENT PROCESS

Unit Times

C901070005
Definition Number of SDCCH drops due to forced release by other calls

Confidential and Proprietary Information of ZTE CORPORATION 151


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of call drop due to forced
releases by other calls (On SDCCH). The counter increments if
the phenomenon that call drops after MS has obtained SDCCH is
caused by forced releases by other calls.
Usage This counter is used to find out the frequency of call drop due to
forced releases by other calls (On SDCCH).
Measurement The counter increments when BSC receives forced release
Point message from other calls on SDCCH. The measurement point is
A, as shown in Figure 97.

FIGURE 97 – CALL DROP DUE TO FORCED RELEASE BY OTHER CALLS IN


IMMEDIATE ASSIGNMENT PROCESS

Unit Times

C901070007
Definition Number of SDCCH drops due to other failure
Description This counter counts the number of call drop due to other failures
(On SDCCH). The counter increments if the phenomenon that
call drops after MS has obtained SDCCH is caused by other
failures except the causes mentioned above (loss of contact with
RANA, radio link failure, LAPD link failure, OMCR forced release,
forced release by other calls, handover failure).
At present, other failure causes are that T3107 is overtime
under ASSIGN status, timer that waits for access is overtime
and T3101 is overtime under WAIT_ACCESS status. Timer that
waits for access indicates the time from radio resource available
message is sent to assignment/handover is finished. T3101
indicates the time from “IMM_ASS” message is sent to
“EST_IND” message is received from MS.
Usage This counter is used to find out the frequency of call drop due to
other failures (On SDCCH).
Measurement The counter increments when T3107 is overtime under ASSIGN
Point status on SDCCH, or when timer that waits for access is
overtime or T3101 is overtime under WAIT_ACCESS status. The
measurement point is A, as shown in Figure 98.

152 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

FIGURE 98 – CALL DROP DUE TO T3101 OVERTIME IN INTRA-CELL HANDOVER

Unit Times

C901070008
Definition Number of signaling TCH/F drops due to loss of contact with
RANA
Description This counter counts the number of failures due to RANCS losing
contact with RANA (on TCH/F signaling channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/F signaling channel is caused by failures due to
RANCS losing contact with RANA.
Usage This counter is used to find out the frequency of failures due to
RANCS losing contact with RANA (on TCH/F signaling channel).
Measurement The counter counts the number of failures due to loss of contact
Point with RANA (On TCH/F signaling) in the following two cases:
„ After link between RANCS and RANA has been established on
TCH/F signaling channel, heartbeat handshake is carried out.
If RANCS or RANA can not receive heartbeat message from
each other during 4 unit times, then it is regarded as link
failure and the counter increments; meanwhile, BSC releases
the channel and instance, the measurement point is A1, as
shown in Figure 93.
„ RANCS forwards “EST_IND” message to RANA after receiving
it on TCH/F signaling; if no link establishment message on A-
interface from RANA is received, the counter increments;
meanwhile, BSC releases the channel and instance, the
measurement point is A2, as shown in Figure 93.
Unit Times

C901070009
Definition Number of signaling TCH/F drops due to radio link failure

Confidential and Proprietary Information of ZTE CORPORATION 153


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of call drop due to radio link
failures (On TCH/F signaling). The counter increments if the
phenomenon that call drops after MS has obtained TCH/F
signaling channel is caused by radio link failures.
Usage This counter is used to find out the frequency of call drop due to
radio link failures (On TCH/F signaling).
Measurement The counter increments when BSC receives “CONNectiOn
Point FAILure INDicatiOn” message on Abis interface on TCH/F
signaling channel. The measurement point is A, as shown in
Figure 94.
Unit Times

C901070010
Definition Number of signaling TCH/F drops due to LAPD link failure
Description This counter counts the number of call drops due to LAPD link
failures (on TCH/F signaling channel). The counter increments if
the phenomenon that call drops after MS has obtained TCH/F
signaling channel is caused by LAPD link failures.
Usage This counter is used to find out the frequency of call drop due to
LAPD link failures (on TCH/F signaling channel).
Measurement The counter increments when BSC receives “DLREL_IND”
Point message from LAPD on TCH/F signaling channel. The
measurement point is A, as shown in Figure 95.
Unit Times

C901070011
Definition Number of signaling TCH/F drops due to OMC-R forced release
Description This counter counts the number of call drop due to OMC-R
forced releases (on TCH/F signaling channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/F signaling channel is caused by OMC-R forced
releases.
Usage This counter is used to find out the frequency of call drop due to
OMC-R forced releases (on TCH/F signaling channel).
Measurement The counter increments when BSC receives OMC-R forced
Point release message from database on TCH/F signaling channel. The
measurement point is A, as shown in Figure 96.
Unit Times

154 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

C901070012
Definition Number of signaling TCH/F drops due to forced release by other
calls
Description This counter counts the number of call drop due to forced
releases by other calls (on TCH/F signaling channel). The
counter increments if the phenomenon that call drops after MS
has obtained TCH/F signaling channel is caused by forced
releases by other calls.
Usage This counter is used to find out the frequency of call drop due to
forced releases by other calls (on TCH/F signaling channel).
Measurement The counter increments when BSC receives forced release
Point message from other calls on TCH/F signaling channel. The
measurement point is A, as shown in Figure 97.
Unit Times

C901070014
Definition Number of signaling TCH/F drops due to other failure
Description This counter counts the number of call drop due to other failures
(on TCH/F signaling channel). The counter increments if the
phenomenon that call drops after MS has obtained TCH/F
signaling channel is caused by other failures except the causes
mentioned above (loss of contact with RANA, radio link failure,
LAPD link failure, OMCR forced release, forced release by other
calls, handover failure).
At present, other failure causes are that T3107 is overtime
under ASSIGN status, timer that waits for access is overtime
and T3101 is overtime under WAIT_ACCESS status. Timer that
waits for access indicates the time from radio resource available
message is sent to assignment/handover is finished. T3101
indicates the time from “IMM_ASS” message is sent to
“EST_IND” message is received from MS.
Usage This counter is used to find out the frequency of call drop due to
other failures (on TCH/F signaling channel).
Measurement The counter increments when T3107 is overtime under ASSIGN
Point status on TCH/F signaling channel, or when timer that waits for
access is overtime or T3101 is overtime under WAIT_ACCESS
status. The measurement point is A, as shown in Figure 98.
Unit Times

C901070015
Definition Number of voice TCH/F drops due to loss of contact with RANA

Confidential and Proprietary Information of ZTE CORPORATION 155


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of failures due to RANCS losing
contact with RANA (on TCH/F voice channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/F voice channel is caused by failures due to
RANCS losing contact with RANA (on TCH/F voice channel).
Usage This counter is used to find out the frequency of failures due to
RANCS losing contact with RANA (on TCH/F voice channel).
Measurement The counter counts the number of failures due to loss of contact
Point with RANA (on TCH/F voice channel) in the following two cases:
„ After link between RANCS and RANA has been established on
TCH/F voice channel, heartbeat handshake is carried out. If
RANCS or RANA can not receive heartbeat message from
each other during 4 unit times, then it is regarded as link
failure and the counter increments; meanwhile, BSC releases
the channel and instance.
„ RANCS forwards “EST_IND” message to RANA after receiving
it on TCH/F voice channel; if no link establishment message
on A-interface from RANA is received, the counter
increments; meanwhile, BSC releases the channel and
instance, the measurement point is A, as shown in Figure 99.

FIGURE 99 – CALL DROP DUE TO A-INTERFACE FAILURE IN ASSIGNMENT


PROCESS

Unit Times

156 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

C901070017
Definition Number of voice TCH/F drops due to LAPD link failure
Description This counter counts the number of call drop due to LAPD link
failures (on TCH/F voice channel). The counter increments if the
phenomenon that call drops after MS has obtained TCH/F voice
channel is caused by LAPD link failures.
Usage This counter is used to find out the frequency of call drop due to
LAPD link failures (on TCH/F voice channel).
Measurement The counter increments when BSC receives “DLREL_IND”
Point message from LAPD on TCH/F voice channel. The measurement
point is A, as shown in Figure 100.

FIGURE 100 – CALL DROP DUE TO LAPD LINK FAILURE IN ASSIGNMENT


PROCESS

Unit Times

C901070018
Definition Number of voice TCH/F drops due to OMC-R forced release
Description This counter counts the number of call drop due to OMC-R
forced releases (on TCH/F voice channel). The counter

Confidential and Proprietary Information of ZTE CORPORATION 157


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

increments if the phenomenon that call drops after MS has


obtained TCH/F voice channel is caused by OMC-R forced
releases.
Usage This counter is used to find out the frequency of call drop due to
OMC-R forced releases (on TCH/F voice channel).
Measurement The counter increments when BSC receives OMC-R forced
Point release message from database on TCH/F voice channel. The
measurement point is A, as shown in Figure 101.

FIGURE 101 – CALL DROP DUE TO OMC-R FORCED RELEASE IN ASSIGNMENT


PROCESS

Unit Times

C901070019
Definition Number of voice TCH/F drops due to forced release by other
calls
Description This counter counts the number of call drop due to forced
releases by other calls (on TCH/F voice channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/F voice channel is caused by forced releases by
other calls.

158 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

Usage This counter is used to find out the frequency of call drop due to
forced releases by other calls (on TCH/F voice channel).
Measurement The counter increments when BSC receives forced release
Point message from other calls on TCH/F voice channel. The
measurement point is A, as shown in Figure 102.

FIGURE 102 – CALL DROP DUE TO FORCED RELEASE BY OTHER CALLS IN


ASSIGNMENT PROCESS

Unit Times

C901070021
Definition Number of voice TCH/F drops due to other failure
Description This counter counts the number of call drop due to other failures
(on TCH/F voice channel). It indicates the call drop case at call
establishment phase due to assignment failure. The counter
increments if the phenomenon that call drops after MS has
obtained TCH/F voice channel is caused by other failures except
the causes mentioned above (loss of contact with RANA, radio
link failure, LAPD link failure, OMCR forced release, forced release
by other calls, handover failure).

Confidential and Proprietary Information of ZTE CORPORATION 159


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

At present, other failure causes are that T3107 is overtime


under ASSIGN status, timer that waits for access is overtime
and T3101 is overtime under WAIT_ACCESS status.
This counter doesn’t count the call drops due to intra-cell
handover failure.
Usage This counter is used to find out the frequency of call drop due to
other failures (on TCH/F voice channel).
Measurement The counter increments when T3107 is overtime under ASSIGN
Point status on TCH/F voice channel, or when timer that waits for
access is overtime or T3101 is overtime under WAIT_ACCESS
status. The measurement point is A, as shown in Figure 98.
Unit Times

C901070022
Definition Number of data TCH/F drops due to loss of contact with RANA
Description This counter counts the number of failures due to RANCS losing
contact with RANA (on TCH/F data channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/F data channel is caused by failures due to RANCS
losing contact with RANA (on TCH/F data channel).
Usage This counter is used to find out the frequency of failures due to
RANCS losing contact with RANA (on TCH/F data channel).
Measurement The counter counts the number of failures due to loss of contact
Point with RANA (on TCH/F data channel) in the following two cases:
„ After link between RANCS and RANA has been established on
TCH/F data channel, heartbeat handshake is carried out. If
RANCS or RANA can not receive heartbeat message from
each other during 4 unit times, then it is regarded as link
failure and the counter increments; meanwhile, BSC releases
the channel and instance, the measurement point is A, as
shown in Figure 99.
„ RANCS forwards “EST_IND” message to RANA after receiving
it on TCH/F data channel; if no link establishment message
on A-interface from RANA is received, the counter
increments; meanwhile, BSC releases the channel and
instance.
Unit Times

C901070023
Definition Number of data TCH/F drops due to radio link failure
Description This counter counts the number of call drop due to radio link
failures (on TCH/F data channel). The counter increments if the

160 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

phenomenon that call drops after MS has obtained TCH/F data


channel is caused by radio link failures.
Usage This counter is used to find out the frequency of call drop due to
radio link failures (on TCH/F data channel).
Measurement The counter increments when BSC receives “CONNectiOn
Point FAILure INDicatiOn” message on Abis interface on TCH/F data
channel. The measurement point is A, as shown in Figure 103.

FIGURE 103 – CALL DROP DUE TO RADIO LINK FAILURE IN ASSIGNMENT


PROCESS

Unit Times

C901070024
Definition Number of data TCH/F drops due to LAPD link failure
Description This counter counts the number of call drop due to LAPD link
failures (on TCH/F data channel). The counter increments if the
phenomenon that call drops after MS has obtained TCH/F data
channel is caused by LAPD link failures.
Usage This counter is used to find out the frequency of call drop due to
LAPD link failures (on TCH/F data channel).

Confidential and Proprietary Information of ZTE CORPORATION 161


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement The counter increments when BSC receives “DLREL_IND”


Point message from LAPD on TCH/F data channel. The measurement
point is A, as shown in Figure 100.
Unit Times

C901070025
Definition Number of data TCH/F drops due to OMC-R forced release
Description This counter counts the number of call drop due to OMC-R
forced releases (on TCH/F data channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/F data channel is caused by OMC-R forced
releases.
Usage This counter is used to find out the frequency of call drop due to
OMC-R forced releases (on TCH/F data channel).
Measurement The counter increments when BSC receives OMC-R forced
Point release message from database on TCH/F data channel. The
measurement point is A, as shown in Figure 101.
Unit Times

C901070026
Definition Number of data TCH/F drops due to forced release by other calls
Description This counter counts the number of call drop due to forced
releases by other calls (on TCH/F data channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/F data channel is caused by forced releases by
other calls.
Usage This counter is used to find out the frequency of call drop due to
forced releases by other calls (on TCH/F data channel).
Measurement The counter increments when BSC receives forced release
Point message from other calls on TCH/F data channel. The
measurement point is A, as shown in Figure 102.
Unit Times

C901070028
Definition Number of data TCH/F drops due to other failure
Description This counter counts the number of call drop due to other failures
(on TCH/F data channel). The counter increments if the
phenomenon that call drops after MS has obtained TCH/F data
channel is caused by other failures except the causes mentioned
above (loss of contact with RANA, radio link failure, LAPD link

162 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

failure, OMCR forced release, forced release by other calls, handover


failure).
At present, other failure causes are that T3107 is overtime
under ASSIGN status, timer that waits for access is overtime
and T3101 is overtime under WAIT_ACCESS status.
Usage This counter is used to find out the frequency of call drop due to
other failures (on TCH/F data channel).
Measurement The counter increments when T3107 is overtime under ASSIGN
Point status on TCH/F data channel, or when timer that waits for
access is overtime or T3101 is overtime under WAIT_ACCESS
status. The measurement point is A, as shown in Figure 98.
Unit Times

C901070029
Definition Number of signaling TCH/H drops due to loss of contact with
RANA
Description This counter counts the number of failures due to RANCS losing
contact with RANA (on TCH/H signaling channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/H signaling channel is caused by failures due to
RANCS losing contact with RANA (on TCH/H signaling channel).
Usage This counter is used to find out the frequency of failures due to
RANCS losing contact with RANA (on TCH/H signaling channel).
Measurement The counter counts the number of failures due to loss of contact
Point with RANA (on TCH/H signaling channel) in the following two
cases:
„ After link between RANCS and RANA has been established on
TCH/H signaling channel, heartbeat handshake is carried out.
If RANCS or RANA can not receive heartbeat message from
each other during 4 unit times, then it is regarded as link
failure and the counter increments; meanwhile, BSC releases
the channel and instance, the measurement point is A1, as
shown in Figure 93.
„ RANCS forwards “EST_IND” message to RANA after receiving
it on TCH/H signaling; if no link establishment message on A-
interface from RANA is received, the counter increments;
meanwhile, BSC releases the channel and instance, the
measurement point is A2, as shown in Figure 93.
Unit Times

C901070030
Definition Number of signaling TCH/H drops due to radio link failure

Confidential and Proprietary Information of ZTE CORPORATION 163


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of call drop due to radio link
failures (on TCH/H signaling channel). The counter increments if
the phenomenon that call drops after MS has obtained TCH/H
signaling channel is caused by radio link failures.
Usage This counter is used to find out the frequency of call drop due to
radio link failures (on TCH/H signaling channel).
Measurement The counter increments when BSC receives “CONNectiOn
Point FAILure INDicatiOn” message on Abis interface on TCH/H
signaling channel. The measurement point is A, as shown in
Figure 94.
Unit Times

C901070031
Definition Number of signaling TCH/H drops due to LAPD link failure
Description This counter counts the number of call drop due to LAPD link
failures (on TCH/H signaling channel). The counter increments if
the phenomenon that call drops after MS has obtained TCH/H
signaling channel is caused by LAPD link failures.
Usage This counter is used to find out the frequency of call drop due to
LAPD link failures (on TCH/H signaling channel).
Measurement The counter increments when BSC receives “DLREL_IND”
Point message from LAPD on TCH/H signaling channel. The
measurement point is A, as shown in Figure 95.
Unit Times

C901070032
Definition Number of signaling TCH/H drops due to OMC-R forced release
Description This counter counts the number of call drop due to OMC-R
forced releases (on TCH/H signaling channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/H signaling channel is caused by OMC-R forced
releases.
Usage This counter is used to find out the frequency of call drop due to
OMC-R forced releases (on TCH/H signaling channel).
Measurement The counter increments when BSC receives OMC-R forced
Point release message from database on TCH/H signaling channel. The
measurement point is A, as shown in Figure 96.
Unit Times

164 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

C901070033
Definition Number of signaling TCH/H drops due to forced release by other
calls
Description This counter counts the number of call drop due to forced
releases by other calls (on TCH/H signaling channel). The
counter increments if the phenomenon that call drops after MS
has obtained TCH/H signaling channel is caused by forced
releases by other calls.
Usage This counter is used to find out the frequency of call drop due to
forced releases by other calls (on TCH/H signaling channel).
Measurement The counter increments when BSC receives forced release
Point message from other calls on TCH/H signaling channel. The
measurement point is A, as shown in Figure 97.
Unit Times

C901070035
Definition Number of signaling TCH/H drops due to other failure
Description This counter counts the number of call drop due to other failures
(on TCH/H signaling channel). The counter increments if the
phenomenon that call drops after MS has obtained TCH/H
signaling channel is caused by other failures except the causes
mentioned above (loss of contact with RANA, radio link failure,
LAPD link failure, OMCR forced release, forced release by other
calls, handover failure).
At present, other failure causes are that T3107 is overtime
under ASSIGN status, timer that waits for access is overtime
and T3101 is overtime under WAIT_ACCESS status.
Usage This counter is used to find out the frequency of call drop due to
other failures (on TCH/H signaling channel).
Measurement The counter increments when T3107 is overtime under ASSIGN
Point status on TCH/H signaling channel, or when timer that waits for
access is overtime or T3101 is overtime under WAIT_ACCESS
status. The measurement point is A, as shown in Figure 98.
Unit Times

C901070036
Definition Number of voice TCH/H drops due to loss of contact with RANA
Description This counter counts the number of failures due to RANCS losing
contact with RANA (on TCH/H voice channel). The counter
increments if the phenomenon that call drops after MS has

Confidential and Proprietary Information of ZTE CORPORATION 165


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

obtained TCH/H voice channel is caused by failures due to


RANCS losing contact with RANA (on TCH/H voice channel).
Usage This counter is used to find out the frequency of failures due to
RANCS losing contact with RANA (on TCH/H voice channel).
Measurement The counter counts the number of failures due to loss of contact
Point with RANA (on TCH/H voice channel) in the following two cases:
„ After link between RANCS and RANA has been established on
TCH/H voice channel, heartbeat handshake is carried out. If
RANCS or RANA can not receive heartbeat message from
each other during 4 unit times, then it is regarded as link
failure and the counter increments; meanwhile, BSC releases
the channel and instance.
„ RANCS forwards “EST_IND” message to RANA after receiving
it on TCH/H voice channel; if no link establishment message
on A-interface from RANA is received, the counter
increments; meanwhile, BSC releases the channel and
instance, the measurement point is A, as shown in Figure 99.
Unit Times

C901070038
Definition Number of voice TCH/H drops due to LAPD link failure
Description This counter counts the number of call drop due to LAPD link
failures (on TCH/H voice channel). The counter increments if the
phenomenon that call drops after MS has obtained TCH/H voice
channel is caused by LAPD link failures.
Usage This counter is used to find out the frequency of call drop due to
LAPD link failures (on TCH/H voice channel).
Measurement The counter increments when BSC receives “DLREL_IND”
Point message from LAPD on TCH/H voice channel. The measurement
point is A, as shown in Figure 100.
Unit Times

C901070039
Definition Number of voice TCH/H drops due to OMC-R forced release
Description This counter counts the number of call drop due to OMC-R
forced releases (on TCH/H voice channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/H voice channel is caused by OMC-R forced
releases.
Usage This counter is used to find out the frequency of call drop due to
OMC-R forced releases (on TCH/H voice channel).

166 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

Measurement The counter increments when BSC receives OMC-R forced


Point release message from database on TCH/H voice channel. The
measurement point is A, as shown in Figure 101.
Unit Times

C901070040
Definition Number of voice TCH/H drops due to forced release by other
calls
Description This counter counts the number of call drop due to forced
releases by other calls (on TCH/H voice channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/H voice channel is caused by forced releases by
other calls.
Usage This counter is used to find out the frequency of call drop due to
forced releases by other calls (on TCH/H voice channel).
Measurement The counter increments when BSC receives forced release
Point message from other calls on TCH/H voice channel. The
measurement point is A, as shown in Figure 102.
Unit Times

C901070042
Definition Number of voice TCH/H drops due to other failure
Description This counter counts the number of call drop due to other failures
(on TCH/H voice channel). The counter increments if the
phenomenon that call drops after MS has obtained TCH/H voice
channel is caused by other failures except the causes mentioned
above (loss of contact with RANA, radio link failure, LAPD link
failure, OMCR forced release, forced release by other calls, handover
failure).
At present, other failure causes are that T3107 is overtime
under ASSIGN status, timer that waits for access is overtime
and T3101 is overtime under WAIT_ACCESS status.
Usage This counter is used to find out the frequency of call drop due to
other failures (on TCH/H voice channel).
Measurement The counter increments when T3107 is overtime under ASSIGN
Point status on TCH/H voice channel, or when timer that waits for
access is overtime or T3101 is overtime under WAIT_ACCESS
status. The measurement point is A, as shown in Figure 98.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 167


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901070043
Definition Number of data TCH/H drops due to loss of contact with RANA
Description This counter counts the number of failures due to RANCS losing
contact with RANA (on TCH/H data channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/H data channel is caused by failures due to RANCS
losing contact with RANA (on TCH/H data channel).
Usage This counter is used to find out the frequency of failures due to
RANCS losing contact with RANA (on TCH/H data channel).
Measurement The counter counts the number of failures due to loss of contact
Point with RANA (on TCH/H data channel) in the following two cases:
„ After link between RANCS and RANA has been established on
TCH/H data channel, heartbeat handshake is carried out. If
RANCS or RANA can not receive heartbeat message from
each other during 4 unit times, then it is regarded as link
failure and the counter increments; meanwhile, BSC releases
the channel and instance.
„ RANCS forwards “EST_IND” message to RANA after receiving
it on TCH/H data channel; if no link establishment message
on A-interface from RANA is received, the counter
increments; meanwhile, BSC releases the channel and
instance, the measurement point is A, as shown in Figure 99.
Unit Times

C901070044
Definition Number of data TCH/H drops due to radio link failure
Description This counter counts the number of call drop due to radio link
failures (on TCH/H data channel). The counter increments if the
phenomenon that call drops after MS has obtained TCH/H data
channel is caused by radio link failures.
Usage This counter is used to find out the frequency of call drop due to
radio link failures (on TCH/H data channel).
Measurement The counter increments when BSC receives “CONNectiOn
Point FAILure INDicatiOn” message on Abis interface on TCH/H data
channel. The measurement point is A, as shown in Figure 103.
Unit Times

C901070045
Definition Number of data TCH/H drops due to LAPD link failure

168 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

Description This counter counts the number of call drop due to LAPD link
failures (on TCH/H data channel). The counter increments if the
phenomenon that call drops after MS has obtained TCH/H data
channel is caused by LAPD link failures.
Usage This counter is used to find out the frequency of call drop due to
LAPD link failures (on TCH/H data channel).
Measurement The counter increments when BSC receives “DLREL_IND”
Point message from LAPD on TCH/H data channel. The measurement
point is A, as shown in Figure 100.
Unit Times

C901070046
Definition Number of data TCH/H drops due to OMC-R forced release
Description This counter counts the number of call drop due to OMC-R
forced releases (on TCH/H data channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/H data channel is caused by OMC-R forced
releases.
Usage This counter is used to find out the frequency of call drop due to
OMC-R forced releases (on TCH/H data channel).
Measurement The counter increments when BSC receives OMC-R forced
Point release message from database on TCH/H data channel. The
measurement point is A, as shown in Figure 101.
Unit Times

C901070047
Definition Number of data TCH/H drops due to forced release by other calls
Description This counter counts the number of call drop due to forced
releases by other calls (on TCH/H data channel). The counter
increments if the phenomenon that call drops after MS has
obtained TCH/H data channel is caused by forced releases by
other calls.
Usage This counter is used to find out the frequency of call drop due to
forced releases by other calls (on TCH/H data channel).
Measurement The counter increments when BSC receives forced release
Point message from other calls on TCH/H data channel. The
measurement point is A, as shown in Figure 102.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 169


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901070049
Definition Number of data TCH/H drops due to other failure
Description This counter counts the number of call drop due to other failures
(on TCH/H data channel). The counter increments if the
phenomenon that call drops after MS has obtained TCH/H data
channel is caused by other failures except the causes mentioned
above (loss of contact with RANA, radio link failure, LAPD link
failure, OMCR forced release, forced release by other calls, handover
failure).
At present, other failure causes are that T3107 is overtime
under ASSIGN status, timer that waits for access is overtime
and T3101 is overtime under WAIT_ACCESS status.
Usage This counter is used to find out the frequency of call drop due to
other failures (on TCH/H data channel).
Measurement The counter increments when T3107 is overtime under ASSIGN
Point status on TCH/H data channel, or when timer that waits for
access is overtime or T3101 is overtime under WAIT_ACCESS
status. The measurement point is A, as shown in Figure 98.
Unit Times

C901070053
Definition Number of SDCCH link failures
Description This counter counts the number of SDCCH link failures. The
counter increments when RANA launches abnormal release flow
to RANCS due to SCCP link failure after MS has obtained SDCCH.
Usage This counter is used to find out the frequency of SDCCH link
failures.
Measurement The counter counts the number of abnormal release flow
Point launched by RANA to RANCS due to SCCP link failure on SDCCH,
including the following cases:
„ T9105 is overtime, the measurement point is A2, as shown
in Figure 104.

170 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

FIGURE 104 – CALL DROP DUE TO SCCP FAILURE IN IMMEDIATE


ASSIGNMENT PROCESS

„ T9104 is overtime and the number of maximum failure times


is reached, the measurement point is A3, as shown in Figure
104.
„ T9101 is overtime, the measurement point is A4, as shown
in Figure 104.
„ After RANA process has been established, “EST_IND”
message sent by MS or handover request sent by MSC is not
received within the set time, the measurement point is A1,
as shown in Figure 104.
„ BSC receives MSC reset message.
„ CONNECT_ID requested by RANA is failed.
„ BSC receives link release command from MSC.
Unit Times

C901070054
Definition Number of TCH/F link failures
Description This counter counts the number of TCH/F link failures. The
counter increments when RANA launches abnormal release flow
to RANCS due to SCCP link failure after MS has obtained TCH/F.
Usage This counter is used to find out the frequency of TCH/F link
failures.

Confidential and Proprietary Information of ZTE CORPORATION 171


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement The counter counts the number of abnormal release flow


Point launched by RANA to RANCS due to SCCP link failure on TCH/F
in the following cases:
„ T9105 is overtime, the measurement point is A2, as shown
in Figure 104.
„ T9104 is overtime and the number of maximum failure times
is reached, the measurement point is A3, as shown in Figure
104.
„ T9101 is overtime, the measurement point is A4, as shown
in Figure 104.
„ After RANA process has been established, “EST_IND”
message sent by MS or handover request sent by MSC is not
received within the set time, the measurement point is A1,
as shown in Figure 104.
„ BSC receives MSC reset message.
„ CONNECT_ID requested by RANA is failed.
„ BSC receives link release command from MSC.
Unit Times

C901070055
Definition Number of TCH/H link failures
Description This counter counts the number of TCH/H link failures. The
counter increments when RANA launches abnormal release flow
to RANCS due to SCCP link failure after MS has obtained TCH/H.
Usage This counter is used to find out the frequency of TCH/H link
failures.
Measurement The counter counts the number of abnormal release flow
Point launched by RANA to RANCS due to SCCP link failure on TCH/H
in the following cases:
„ T9105 is overtime, the measurement point is A2, as shown
in Figure 104.
„ T9104 is overtime and the number of maximum failure times
is reached, the measurement point is A3, as shown in Figure
104.
„ T9101 is overtime, the measurement point is A4, as shown
in Figure 104.
„ After RANA process has been established, “EST_IND”
message sent by MS or handover request sent by MSC is not
received within the set time, the measurement point is A1,
as shown in Figure 104.
„ BSC receives MSC reset message.
„ CONNECT_ID requested by RANA is failed.

172 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

„ BSC receives link release command from MSC.


Unit Times

C901070056
Definition Number of RANA link releases due to other cause on SDCCH
Description This counter counts the number of RANA link releases by other
cause on SDCCH (except that SCCP link release command
message is received). The counter increments if RANA link
release occurs after MS has obtained SDCCH.
Usage This counter is used to find out the frequency of RANA link
releases by other cause on SDCCH.
Measurement The counter increments when the content of “HO_REQ” message
Point is incorrect. The measurement point is A2, as shown in Figure
105.

FIGURE 105 – CALL DROP DUE TO INTER-BSC HANDOVER FAILURE

MS BTS1 BSC1 MSC BSC2 BTS2


Meas Rep
Meas Rep
Ho Req
CR(Ho Req)

CC A2
Chan Act
Chan Act Ack
Ho Req Ack
Ho cmd
Ho Cmd HO Detec
HO Detec
A1 Est Ind
HO Complete

Clear Cmd

Unit Times

C901070057
Definition Number of RANA link releases due to other cause on TCH/F
Description This counter counts the number of RANA link releases by other
cause on TCH/F (except that SCCP link release command
message is received). The counter increments if RANA link
release occurs after MS has obtained TCH/F.
Usage This counter is used to find out the frequency of RANA link
releases by other cause on TCH/F.
Measurement The counter increments when the content of “HO_REQ” message
Point is incorrect. The measurement point is A2, as shown in Figure
105.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 173


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901070058
Definition Number of RANA link releases due to other cause on TCH/H
Description This counter counts the number of RANA link releases by other
cause on TCH/H (except that SCCP link release command
message is received). The counter increments if RANA link
release occurs after MS has obtained TCH/H.
Usage This counter is used to find out the frequency of RANA link
releases by other cause on TCH/H.
Measurement The counter increments when the content of “HO_REQ” message
Point is incorrect. The measurement point is A2, as shown in Figure
105.
Unit Times

C901070059
Definition Number of SDCCH short messages drops
Description This counter counts the number of SDCCH short messages drops.
The counter increments when call drops after MS has obtained
SDCCH for short message service.
Usage This counter is used to find out the frequency of SDCCH short
messages drops.
Measurement The counter increments when call drops due to radio link failure
Point or LAPD link release or handover failure while doing short
message service.
Unit Times

C901070060
Definition Number of TCH/F short messages drops
Description This counter counts the number of TCH/F short messages drops.
The counter increments when call drops after MS has obtained
TCH/F for short message service.
Usage This counter is used to find out the frequency of TCH/F short
messages drops.
Measurement The counter increments when call drops due to radio link failure
Point or LAPD link release or handover failure while doing short
message service.
Unit Times

174 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

C901070061
Definition Number of TCH/H short messages drops
Description This counter counts the number of TCH/H short messages drops.
The counter increments when call drops after MS has obtained
TCH/H for short message service.
Usage This counter is used to find out the frequency of TCH/H short
messages drops.
Measurement The counter increments when call drops due to radio link failure
Point or LAPD link release or handover failure while doing short
message service.
Unit Times

C901070062
Definition Number of TCH/F drops due to CS channel is forced release by
PS
Description When CS service channel is forcibly released due to PS service,
handover is initiated, and call drop will occur if TCH/F channel
request fails. In such a case, the counter increments.
Usage This counter is used to find out the frequency of call drops due
to TCH/F channel request failure when CS service channel is
forcedly released due to PS service.
Measurement The counter increments when call drops due to TCH/F channel
Point request failure when CS service is forcedly released due to PS
service.
Unit Times

C901070063
Definition Number of TCH/H drops due to CS channel is forced release by
PS
Description When CS service channel is forcibly released due to PS service,
handover is initiated, and call drop will occur if TCH/H channel
request fails. In such a case, the counter increments.
Usage This counter is used to find out the frequency of call drops due
to TCH/H channel request failure when CS service channel is
forcedly released due to PS service.
Measurement The counter increments when call drops due to TCH/H channel
Point request failure when CS service is forcedly released due to PS
service.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 175


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901070064
Definition Number of SDCCH drops due to eMLPP forced handover
Description This counter counts the number of call drops on SDCCH due to
eMLPP forced handover. After MS obtains SDCCH, call drop
occurs. If the problem is caused by eMLPP forced handover, the
counter increments.
Usage This counter is used to find out the frequency of call drop on
SDCCH due to eMLPP forced handover.
Measurement The counter counts when T3107 and T3103 are timeout under
Point ASSIGN status on SDCCH. The measurement point is A, as
shown in Figure 106.

FIGURE 106 – MEASUREMENT POINT OF NUMBER OF SDCCH DROPS DUE TO


EMLPP FORCED HANDOVER

Unit Times

C901070065
Definition Number of signaling TCH/F drops due to eMLPP forced handover
Description This counter counts the number of call drops on signaling TCH/F
due to eMLPP forced handover. After MS obtains signaling TCH/F,
call drop occurs. If the problem is caused by eMLPP forced
handover, the counter increments.
Usage This counter is used to find out the frequency of call drop on
signaling TCH/F due to eMLPP forced handover
Measurement The counter counts when T3107 and T3103 are timeout under
Point ASSIGN status on signaling TCH/F. The measurement point is A,
as shown in Figure 106.
Unit Times

176 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

C901070066
Definition Number of voice TCH/F drops due to eMLPP forced handover
Description This counter counts the number of call drops on voice TCH/F due
to eMLPP forced handover. After MS obtains voice TCH/F, call
drop occurs. If the problem is caused by eMLPP forced handover,
the counter increments.
Usage This counter is used to find out the frequency of call drop on
voice TCH/F due to eMLPP forced handover.
Measurement The counter counts when T3107 and T3103 are timeout under
Point ASSIGN status on voice TCH/F. The measurement point is A, as
shown in Figure 106.
Unit Times

C901070067
Definition Number of data TCH/F drops due to eMLPP forced handover
Description This counter counts the number of call drops on data TCH/F due
to eMLPP forced handover. After MS obtains data TCH/F, call
drop occurs. If the problem is caused by eMLPP forced handover,
the counter increments.
Usage This counter is used to find out the frequency of call drop on
data TCH/F due to eMLPP forced handover.
Measurement The counter counts when T3107 and T3103 are timeout under
Point ASSIGN status on data TCH/F. The measurement point is A, as
shown in Figure 106.
Unit Times

C901070068
Definition Number of signaling TCH/H drops due to eMLPP forced handover
Description This counter counts the number of call drops on signaling TCH/H
due to eMLPP forced handover. After MS obtains signaling TCH/H,
call drop occurs. If the problem is caused by eMLPP forced
handover, the counter increments.
Usage This counter is used to find out the frequency of call drop on
signaling TCH/H due to eMLPP forced handover.
Measurement The counter counts when T3107 and T3103 are timeout under
Point ASSIGN status on signaling TCH/H. The measurement point is A,
as shown in Figure 106.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 177


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901070069
Definition Number of voice TCH/H drops due to eMLPP forced handover
Description This counter counts the number of call drops on voice TCH/H
due to eMLPP forced handover. After MS obtains voice TCH/H,
call drop occurs. If the problem is caused by eMLPP forced
handover, the counter increments.
Usage This counter is used to find out the frequency of call drop on
voice TCH/H due to eMLPP forced handover.
Measurement The counter counts when T3107 and T3103 are timeout under
Point ASSIGN status on voice TCH/H. The measurement point is A, as
shown in Figure 106.
Unit Times

C901070070
Definition Number of data TCH/H drops due to eMLPP forced handover
Description This counter counts the number of call drops on data TCH/H due
to eMLPP forced handover. After MS obtains data TCH/H, call
drop occurs. If the problem is caused by eMLPP forced handover,
the counter increments.
Usage This counter is used to find out the frequency of call drop on
data TCH/H due to eMLPP forced handover.
Measurement The counter counts when T3107 and T3103 are timeout under
Point ASSIGN status on data TCH/H. The measurement point is A, as
shown in Figure 106.
Unit Times

C901070071
Definition Bad quality of UL receiving (On SDCCH)
Description This counter counts the number of call drops on SDCCH due to
radio link failure. After MS obtains SDCCH, call drop occurs. If
the problem is caused by bad uplink receiving quality, the
counter increments.
Usage This counter is used to find out the frequency of call drop on
SDCCH due to radio link failure which is caused by bad uplink
receiving quality.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on SDCCH. The
measurement point is A, as shown in Figure 94.
Unit Times

178 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

C901070072
Definition Bad quality of DL receiving (On SDCCH)
Description This counter counts the number of call drops on SDCCH due to
radio link failure. After MS obtains SDCCH, call drop occurs. If
the problem is caused by bad downlink receiving quality, the
counter increments.
Usage This counter is used to find out the frequency of call drop on
SDCCH due to radio link failure which is caused by bad downlink
receiving quality.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on SDCCH. The
measurement point is A, as shown in Figure 94.
Unit Times

C901070073
Definition Lower electrical level of UL (On SDCCH)
Description This counter counts the number of call drops on SDCCH due to
radio link failure. After MS obtains SDCCH, call drop occurs. If
the problem is caused by low uplink receiving level, the counter
increments.
Usage This counter is used to find out the frequency of call drop on
SDCCH due to radio link failure which is caused by low uplink
receiving level.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on SDCCH. The
measurement point is A, as shown in Figure 94.
Unit Times

C901070074
Definition Lower electrical level of DL (On SDCCH)
Description This counter counts the number of call drops on SDCCH due to
radio link failure. After MS obtains SDCCH, call drop occurs. If
the problem is caused by low downlink receiving level, the
counter increments.
Usage This counter is used to find out the frequency of call drop on
SDCCH due to radio link failure which is caused by low downlink
receiving level.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on SDCCH. The
measurement point is A, as shown in Figure 94.

Confidential and Proprietary Information of ZTE CORPORATION 179


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Unit Times

C901070075
Definition Number of signaling drops due to TA too far (On SDCCH)
Description This counter counts the number of call drops on SDCCH due to
radio link failure. After MS obtains SDCCH, call drop occurs. If
the problem is caused by TA being too far, the counter
increments.
Usage This counter is used to find out the frequency of call drop on
SDCCH due to radio link failure which is caused by TA being too
far.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on SDCCH. The
measurement point is A, as shown in Figure 94.
Unit Times

C901070076
Definition Reasons of the other radios (On SDCCH)
Description This counter counts the number of call drops on SDCCH due to
radio link failure. After MS obtains SDCCH, call drop occurs. If
the problem is not due to the above five causes (i.e. bad uplink
receiving quality, bad downlink receiving quality, low uplink
receiving level, low downlink receiving level, and TA being too
far), the counter increments.
Usage This counter is used to find out the frequency of call drop on
SDCCH due to radio link failure which is caused by other radio
problems.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on SDCCH. The
measurement point is A, as shown in Figure 94.
Unit Times

C901070077
Definition Bad quality of UL receiving (On TCH/F)
Description This counter counts the number of call drops on TCH/F due to
radio link failure. After MS obtains TCH/F, call drop occurs. If the
problem is caused by bad uplink receiving quality, the counter
increments.

180 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

Usage This counter is used to find out the frequency of call drop on
TCH/F due to radio link failure which is caused by bad uplink
receiving quality.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on TCH/F. The
measurement point is A, as shown in Figure 94.
Unit Times

C901070078
Definition Bad quality of DL receiving (On TCH/F)
Description This counter counts the number of call drops on TCH/F due to
radio link failure. After MS obtains TCH/F, call drop occurs. If the
problem is caused by bad downlink receiving quality, the counter
increments.
Usage This counter is used to find out the frequency of call drop on
TCH/F due to radio link failure which is caused by bad downlink
receiving quality.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on TCH/F. The
measurement point is A, as shown in Figure 103.
Unit Times

C901070079
Definition Lower electrical level of UL (On TCH/F)
Description This counter counts the number of call drops on TCH/F due to
radio link failure. After MS obtains TCH/F, call drop occurs. If the
problem is caused by low uplink receiving level, the counter
increments.
Usage This counter is used to find out the frequency of call drop on
TCH/F due to radio link failure which is caused by low uplink
receiving level.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on TCH/F. The
measurement point is A, as shown in Figure 103.
Unit Times

C901070080
Definition Lower electrical level of DL (On TCH/F)
Description

Confidential and Proprietary Information of ZTE CORPORATION 181


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This counter counts the number of call drops on TCH/F due to


radio link failure. After MS obtains TCH/F, call drop occurs. If the
problem is caused by low downlink receiving level, the counter
increments.
Usage This counter is used to find out the frequency of call drop on
TCH/F due to radio link failure which is caused by low downlink
receiving level.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on TCH/F. The
measurement point is A, as shown in Figure 103.
Unit Times

C901070081
Definition Number of signaling drops due to TA too far (On TCH/F)
Description This counter counts the number of call drops on TCH/F due to
radio link failure. After MS obtains TCH/F, call drop occurs. If the
problem is caused by TA being too far, the counter increments.
Usage This counter is used to find out the frequency of call drop on
TCH/F due to radio link failure which is caused by TA being too
far.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on TCH/F. The
measurement point is A, as shown in Figure 103.
Unit Times

C901070082
Definition Reasons of the other radios (On TCH/F)
Description This counter counts the number of call drops on TCH/F due to
radio link failure. After MS obtains TCH/F, call drop occurs. If the
problem is not due to the above five causes (i.e. bad uplink
receiving quality, bad downlink receiving quality, low uplink
receiving level, low downlink receiving level, and TA being too
far), the counter increments.
Usage This counter is used to find out the frequency of call drop on
TCH/F due to radio link failure which is caused by other radio
problems.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on TCH/F. The
measurement point is A, as shown in Figure 103.
Unit Times

182 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

C901070083
Definition Bad quality of UL receiving (On TCH/H)
Description This counter counts the number of call drops on TCH/H due to
radio link failure. After MS obtains TCH/H, call drop occurs. If the
problem is caused by bad uplink receiving quality, the counter
increments.
Usage This counter is used to find out the frequency of call drop on
TCH/H due to radio link failure which is caused by bad uplink
receiving quality.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on TCH/H. The
measurement point is A, as shown in Figure 103.
Unit Times

C901070084
Definition Bad quality of DL receiving (On TCH/H)
Description This counter counts the number of call drops on TCH/H due to
radio link failure. After MS obtains TCH/H, call drop occurs. If the
problem is caused by bad downlink receiving quality, the counter
increments.
Usage This counter is used to find out the frequency of call drop on
TCH/H due to radio link failure which is caused by bad downlink
receiving quality.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on TCH/H. The
measurement point is A, as shown in Figure 103.
Unit Times

C901070085
Definition Lower electrical level of UL (On TCH/H)
Description This counter counts the number of call drops on TCH/H due to
radio link failure. After MS obtains TCH/H, call drop occurs. If the
problem is caused by low uplink receiving level, the counter
increments.
Usage This counter is used to find out the frequency of call drop on
TCH/H due to radio link failure which is caused by low uplink
receiving level.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on TCH/H. The
measurement point is A, as shown in Figure 103.

Confidential and Proprietary Information of ZTE CORPORATION 183


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Unit Times

C901070086
Definition Lower electrical level of DL (On TCH/H)
Description This counter counts the number of call drops on TCH/H due to
radio link failure. After MS obtains TCH/H, call drop occurs. If the
problem is caused by low downlink receiving level, the counter
increments.
Usage This counter is used to find out the frequency of call drop on
TCH/H due to radio link failure which is caused by low downlink
receiving level.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on TCH/H. The
measurement point is A, as shown in Figure 103.
Unit Times

C901070087
Definition Number of signaling drops due to TA too far (On TCH/H)
Description This counter counts the number of call drops on TCH/H due to
radio link failure. After MS obtains TCH/H, call drop occurs. If the
problem is caused by TA being too far, the counter increments.
Usage This counter is used to find out the frequency of call drop on
TCH/H due to radio link failure which is caused by TA being too
far.
Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on TCH/H. The
measurement point is A, as shown in Figure 103.
Unit Times

C901070088
Definition Reasons of the other radios (On TCH/H)
Description This counter counts the number of call drops on TCH/H due to
radio link failure. After MS obtains TCH/H, call drop occurs. If the
problem is not due to the above five causes (i.e. bad uplink
receiving quality, bad downlink receiving quality, low uplink
receiving level, low downlink receiving level, and TA being too
far), the counter increments.
Usage This counter is used to find out the frequency of call drop on
TCH/H due to radio link failure which is caused by other radio
problems.

184 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - RMM Call Drop Measurement

Measurement The counter counts when BSC receives the CONNectiOn FAILure
Point INDicatiOn message at Abis interface on TCH/H. The
measurement point is A, as shown in Figure 103.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 185


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

186 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9

Radio Resource
Availability Measurement

Radio resource available measurement describes the utilizing


status of radio channel resource in each cell. This chapter
introduces definitions, usages and measurement points of
counters in radio resource available measurement.

Overview
Radio resource available measurement counters count the
number, mean number and the maximum busy number of
available SDCCH, TCH/H and TCH/F, as well as total busy and
congestion time of these channels in the cell.
The measurement takes cell as the statistics unit.

Radio Resource Availability


Measurement Counter Index
Table 13 lists counters related to radio resource availability
measurement.

T AB L E 1 3 - R AD I O R E S O U R C E AV AI L AB I L I T Y M E AS U R E M E N T C O U N T E RS

Counter What It Counts


C901080003 Peak processor load
C901080004 Average processor load
C901080006 SDCCH congestion time
C901080008 Number of unavailable defined SDCCH
C901080011 Maximum number of busy radio channel
C901080012 Average number of busy radio channel

Confidential and Proprietary Information of ZTE CORPORATION 187


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter What It Counts


C901080014 Average number of busy TCH/H
C901080016 TCH/H busy time(SpeechVer1)
C901080017 TCH/H busy time(SpeechVer3)
C901080018 TCH/H congestion time
C901080022 Average number of busy TCH/F
C901080024 TCH/F busy time(SpeechVer1)
C901080025 TCH/F busy time(SpeechVer2)
C901080026 TCH/F busy time(SpeechVer3)
C901080027 TCH/F congestion time
C901080030 Number of TRXs
C901080032 Reserved TCH/F busy time

C901080003
Definition Peak processor load
Description This counter counts the maximum number of busy SDCCHs in
the cell within measurement period; its value represents SDDCH
instantaneous occupation status and the busiest extent.
System records SDCCH occupation number in cells. The
occupation number increments after SDCCH has been occupied
successfully; the occupation number decrements before SDCCH
has been released. The counter value updates as occupation
number if BSC judges that the counter value is smaller than the
occupation number after SDCCH has been occupied successfully
and before SDCCH has been released, as well as when
measurement data are reported periodically.
Update occupation number before SDCCH has been released is
because SDCCH status in the previous measurement period has
been taken into account.
Usage This counter is used to find out the busy extent of SDCCH in
cells, its value can be used as the reference for whether to
increase SDCCH.
Measurement The counter counts in the following three cases:
Point
„ The counter updates if the maximum busy number exceeds
the recorded value after SDCCH has been occupied
successfully;
„ The counter updates if the maximum busy number exceeds
the recorded value before SDCCH has been released;
„ The counter updates if the maximum busy number exceeds
the recorded value when measurement data are reported
periodically. The measurement point is A, as shown in Figure
107.

188 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - Radio Resource Availability Measurement

FIGURE 107 – REPORTING MEASUREMENT DAT A

Unit Times

C901080004
Definition Average processor load.
Description This counter counts the mean number of busy SDCCHs in the
cell within measurement period. The occupation number in
measurement data reported periodically in the system is the
mean number of busy SDCCH.
Usage This counter is used to find out the busy extent of SDCCH in
cells, its value can be used as the reference for whether to
increase SDCCH.
Measurement The counter counts when measurement data are reported
Point periodically. The measurement point is A, as shown in Figure
107.
Unit Times

C901080006
Definition SDCCH congestion time
Description This counter counts the total time of SDCCH congestion.
BSC sets congestion mark when SDCCH request fails, and the
start of congestion time is recorded.
BSC clear congestion mark when SDCCH request succeeds. If
congestion mark is set when requiring SDCCH, then this period
of congestion time is to use the present time minus the previous
recorded congestion time.
If congestion mark is set before SDCCH has been released or
when measurement values are reported periodically, the
congestion time is calculated. The sum of each congestion time
is the total time of SDCCH congestion.
Usage This counter is used to find out the busy extent of SDCCH in
cells, its value can be used as the reference for whether to
increase SDCCH.

Confidential and Proprietary Information of ZTE CORPORATION 189


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement The counter counts in the following three cases:


Point
„ If congestion mark is set before SDCCH has been occupied,
the counter counts congestion time and accumulates.
„ If congestion mark is set before SDCCH has been released,
the counter counts congestion time and accumulates.
„ If congestion mark is set when measurement values are
reported periodically, the counter counts congestion time and
accumulates. The measurement point is A, as shown in
Figure 107.
Unit Second

C901080008
Definition Number of unavailable defined SDCCH
Description iBSC supports dynamic transform between SDCCH and TCH. This
counter counts the number of unavailable static SDCCH
configured by present cell through OMCR.
Usage This counter is used to find out the unavailability of SDCCH in
the present cell for eliminating cell failures.
Measurement The counter value is inquired from database when periodical
Point measurement data are reported. The measurement point is A, as
shown in Figure 107.
Unit Times

C901080011
Definition Maximum number of busy radio channel
Description This counter counts the maximum number of busy radio channel
in the cell within measurement period; its value represents radio
channel instantaneous occupation status and the busiest extent.
Usage This counter is used to find out the busy extent of radio channel
in cells; its value can be used as the reference for whether to
increase TRXs.
Measurement The counter value is inquired from database when periodical
Point measurement data are reported. The measurement point is A, as
shown in Figure 107.
Unit Times

C901080012
Definition Average number of busy radio channel

190 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - Radio Resource Availability Measurement

Description This counter counts the mean number of busy radio channel in
the cell within measurement period. The occupation number in
measurement data reported periodically in the system is the
mean number of busy radio channel.
Usage This counter is used to find out the busy extent of radio channel
in cells; its value can be used as the reference for whether to
increase TRXs.
Measurement The counter value is inquired from database when periodical
Point measurement data are reported. The measurement point is A, as
shown in Figure 107.
Unit Times

C901080014
Definition Average number of busy TCH/H
Description This counter counts the mean number of busy TCH/Hs in the cell
within measurement period. The occupation number in
measurement data reported periodically in the system is the
mean number of busy TCH/Hs.
Usage This counter is used to find out the busy extent of TCH/Hs in
cells; its value can be used as the reference for whether to
increase TCH/Hs.
Measurement Occupation number updates after TCH/H has been occupied and
Point released successfully, the counter value is reported when
measurement data are reported periodically. The measurement
point is A, as shown in Figure 107.
Unit Times

C901080016
Definition TCH/H busy time (SpeechVer1).
Description This counter counts the total TCH/H busy time (SpeechVer1) in
cells; its value represents traffic on TCH/H (SpeechVer1).
Usage This counter is used to find out the busy extent and mean
occupation time of TCH/H in cells; its value can be used as the
reference for whether to increase TCH/Hs.
Measurement The counter counts in the following three cases:
Point
„ The counter counts time and accumulates when TCH/H is
obtained successfully;
„ The counter counts time and accumulates when TCH/H is
released;

Confidential and Proprietary Information of ZTE CORPORATION 191


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

„ The counter counts time and accumulates when


measurement data are reported periodically. The
measurement point is A, as shown in Figure 107.
The measurement formula is:
(Present time – previous measurement time) × Number of
MS that are occupying channels
The reported measurement value is the accumulation of each
measurement value. After each accumulation, the previous
measurement time is updated as the present time. The
number of MS that are occupying channels increments when
TCH/H is obtained successfully after accumulation. The
number of MS that are occupying channels decrements when
TCH/H is released after accumulation.
Unit Second

C901080017
Definition TCH/H busy time(SpeechVer3).
Description This counter counts the total TCH/H busy time (SpeechVer3) in
cells; its value represents traffic on TCH/H (SpeechVer3).
Usage This counter is used to find out the busy extent and mean
occupation time of TCH/H in cells; its value can be used as the
reference for whether to increase TCH/Hs.
Measurement The counter counts in the following three cases:
Point
„ The counter counts time and accumulates when TCH/H is
obtained successfully;
„ The counter counts time and accumulates when TCH/H is
released;
„ The counter counts time and accumulates when
measurement data are reported periodically. The
measurement point is A, as shown in Figure 107.
The measurement formula is:
(Present time – previous measurement time) × Number of
MS that are occupying channels
The reported measurement value is the accumulation of each
measurement value. After each accumulation, the previous
measurement time is updated as the present time. The
number of MS that are occupying channels increments when
TCH/H is obtained successfully after accumulation. The
number of MS that are occupying channels decrements when
TCH/H is released after accumulation.
Unit Second

192 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - Radio Resource Availability Measurement

C901080018
Definition TCH/H congestion time
Description This counter counts the total TCH/H congestion time.
BSC sets congestion mark when TCH/H request fails, and the
start of congestion time is recorded.
BSC clear congestion mark when TCH/H request succeeds. If
congestion mark is set when requiring TCH/H, then this period of
congestion time is to use the present time minus the previous
recorded congestion time.
If congestion mark is set before TCH/H has been released or
when measurement values are reported periodically, the
congestion time is calculated. The sum of each congestion time
is the total time of TCH/H congestion.
Usage This counter is used to find out the busy extent of TCH/H in cells,
its value can be used as the reference for whether to increase
TCH/H.
Measurement The counter counts in the following three cases:
Point
„ If congestion mark is set before TCH/H has been occupied,
the counter counts congestion time and accumulates.
„ If congestion mark is set before TCH/H has been released,
the counter counts congestion time and accumulates.
„ If congestion mark is set when measurement values are
reported periodically, the counter counts congestion time and
accumulates. The measurement point is A, as shown in
Figure 107.
Unit Second

C901080022
Definition Average number of busy TCH/F
Description This counter counts the mean number of busy TCH/Fs in the cell
within measurement period. The occupation number in
measurement data reported periodically in the system is the
mean number of busy TCH/Fs.
Usage This counter is used to find out the busy extent of TCH/Fs in
cells; its value can be used as the reference for whether to
increase TCH/Fs.
Measurement Occupation number updates after TCH/F has been occupied and
Point released successfully, the counter value is reported when
measurement data are reported periodically. The measurement
point is A, as shown in Figure 107.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 193


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901080024
Definition TCH/F busy time (SpeechVer1)
Description This counter counts the total TCH/F busy time (SpeechVer1) in
cells; its value represents traffic on TCH/F (SpeechVer1).
Usage This counter is used to find out the busy extent and mean
occupation time of TCH/F in cells; its value can be used as the
reference for whether to increase TCH/Fs and the proportion of
using SpeechVer1.
Measurement The counter counts in the following three cases:
Point
„ The counter counts time and accumulates when TCH/F is
obtained successfully;
„ The counter counts time and accumulates when TCH/F is
released;
„ The counter counts time and accumulates when
measurement data are reported periodically. The
measurement point is A, as shown in Figure 107.
The measurement formula is:
(Present time – previous measurement time) × Number of
MS that are occupying channels
The reported measurement value is the accumulation of each
measurement value. After each accumulation, the previous
measurement time is updated as the present time. The
number of MS that are occupying channels increments when
TCH/F is obtained successfully after accumulation. The
number of MS that are occupying channels decrements when
TCH/F is released after accumulation.
Unit Second

C901080025
Definition TCH/F busy time (SpeechVer2)
Description This counter counts the total TCH/F busy time (SpeechVer2) in
cells; its value represents traffic on TCH/F (SpeechVer2).
Usage This counter is used to find out the busy extent and mean
occupation time of TCH/F in cells; its value can be used as the
reference for whether to increase TCH/Fs and the proportion of
using SpeechVer2.
Measurement The counter counts in the following three cases:
Point
„ The counter counts time and accumulates when TCH/F is
obtained successfully;
„ The counter counts time and accumulates when TCH/F is
released;

194 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - Radio Resource Availability Measurement

„ The counter counts time and accumulates when


measurement data are reported periodically. The
measurement point is A, as shown in Figure 107.
The measurement formula is:
(Present time – previous measurement time) × Number of
MS that are occupying channels
The reported measurement value is the accumulation of each
measurement value. After each accumulation, the previous
measurement time is updated as the present time. The
number of MS that are occupying channels increments when
TCH/F is obtained successfully after accumulation. The
number of MS that are occupying channels decrements when
TCH/F is released after accumulation.
Unit Second

C901080026
Definition TCH/F busy time(SpeechVer3)
Description This counter counts the total TCH/F busy time (SpeechVer3) in
cells; its value represents traffic on TCH/F (SpeechVer3).
Usage This counter is used to find out the busy extent and mean
occupation time of TCH/F in cells; its value can be used as the
reference for whether to increase TCH/Fs and the proportion of
using SpeechVer3.
Measurement The counter counts in the following three cases:
Point
„ The counter counts time and accumulates when TCH/F is
obtained successfully;
„ The counter counts time and accumulates when TCH/F is
released;
„ The counter counts time and accumulates when
measurement data are reported periodically. The
measurement point is A, as shown in Figure 107.
The measurement formula is:
(Present time – previous measurement time) × Number of
MS that are occupying channels
The reported measurement value is the accumulation of each
measurement value. After each accumulation, the previous
measurement time is updated as the present time. The
number of MS that are occupying channels increments when
TCH/F is obtained successfully after accumulation. The
number of MS that are occupying channels decrements when
TCH/F is released after accumulation.
Unit Second

Confidential and Proprietary Information of ZTE CORPORATION 195


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901080027
Definition TCH/F congestion time
Description This counter counts the total time of TCH/F congestion.
BSC sets congestion mark when TCH/F request fails, and the
start of congestion time is recorded.
BSC clear congestion mark when TCH/F request succeeds. If
congestion mark is set when requiring TCH/F, then this period of
congestion time is to use the present time minus the previous
recorded congestion time.
If congestion mark is set before TCH/F has been released or
when measurement values are reported periodically, the
congestion time is calculated. The sum of each congestion time
is the total time of TCH/F congestion.
Usage This counter is used to find out the busy extent of TCH/F in cells,
its value can be used as the reference for whether to increase
TCH/F.
Measurement The counter counts in the following three cases:
Point
„ If congestion mark is set before TCH/F has been occupied,
the counter counts congestion time and accumulates.
„ If congestion mark is set before TCH/F has been released,
the counter counts congestion time and accumulates.
„ If congestion mark is set when measurement values are
reported periodically, the counter counts congestion time and
accumulates. The measurement point is A, as shown in
Figure 107.
Unit Second

C901080030
Definition Number of TRXs
Description This counter counts the total number of TRXs in all status
configured in the cell.
Usage This counter is used to find out the configured TRX number and
resource utilizing status in the present cell.
Measurement The counter value is inquired from database when periodical
Point measurement data are reported. The measurement point is A, as
shown in Figure 107.
Unit Times

196 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - Radio Resource Availability Measurement

C901080032
Definition Reserved TCH/F busy time
Description Reserved TCH is the channel that can only be occupied by
subscribers with high priority. This counter counts the total busy
time for reserved TCH/F; its value represents traffic of reserved
TCH/F.
Usage This counter is used to find out the utilizing status of reserved
TCH/F to facilitate the configuration adjustment of reserved
TCH/F.
Measurement The counter counts in the following three cases:
Point
„ The counter counts when reserved TCH/F is obtained
successfully;
„ The counter counts when reserved TCH/F is released;
„ The counter counts when measurement values are reported
periodically. The measurement point is A, as shown in Figure
107.
The measurement formula is:
(Present time – previous measurement time) × Number of
MS that are occupying channels
The reported measurement value is the accumulation of each
measurement value. After each accumulation, the previous
measurement time is updated as the present time. The
number of MS that are occupying channels increments when
observed TCH/F is obtained successfully after accumulation.
The number of MS that are occupying channels decrements
when observed TCH/F is released after accumulation.
Unit Second

Confidential and Proprietary Information of ZTE CORPORATION 197


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

198 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10

General Handover
Measurement

General handover measurement aims to measure the process of


MS handover, to find out successes, failures, and causes of
failures, to find out the traffic sharing, and to improve the
wireless configuration of the cell.
This chapter describes the definition, usage and measurement
point of various counters.

Overview
General handover counter is used to find out MS handover
successes, failures, and frequency of abnormal events during
handover. After configured with inter-system handover or
concentric circle, general handover counter is also used to find
out inter-cell traffic sharing to improve the wireless planning.
The measurement takes cell as the statistics unit.

General Handover Measurement


Counter Index
Table 14 lists counters related to general handover
measurement.

TABLE 14 - GENERAL H ANDOVER MEASUREMENT COUNTERS

Counter ID What It Counts


Number of BSC-controlled inter-cell outgoing
C901090001
handover attempts
Number of MSC-controlled outgoing handover
C901090004
attempts

Confidential and Proprietary Information of ZTE CORPORATION 199


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter ID What It Counts


Number of MSC-controlled outgoing handover
C901090005
request failures due to unclear factors
Number of MSC-controlled outgoing handover
C901090006
request failures due to unavailable ground resource
Number of MSC-controlled outgoing handover
C901090007
request failures due to unavailable radio resource
Number of MSC-controlled outgoing handover
C901090008
request failures due to other factors
Number of BSC-controlled inter-cell incoming
C901090011
handover attempts
Number of BSC-controlled incoming handover
C901090013
attempts due to forced release
Number of BSC-controlled incoming handover
C901090015
attempts due to queue
Number of BSC-controlled incoming handover
C901090017
attempts due to forced handover
BSC-controlled incoming handover time due to
C901090020
queue
Number of BSC-controlled incoming handover due
C901090021
to queue
BSC-controlled incoming handover success time
C901090022
due to queue
Number of BSC-controlled incoming handover
C901090023
success due to queue
Number of MSC-controlled incoming handover
C901090024
attempts
Number of incoming handover failure due to circuit
C901090025
block
Number of incoming handover failure due to circuit
C901090026
group mismatch
Number of incoming handover failure due to
C901090027
unavailable radio resource
Number of incoming handover failure due to other
C901090028
factors
Number of MSC-controlled incoming handover
C901090030
attempts due to forced release
Number of MSC-controlled incoming handover
C901090032
attempts due to queue
Number of MSC-controlled incoming handover
C901090034
attempts due to forced release
MSC-controlled incoming handover time due to
C901090037
queue
Number of MSC-controlled incoming handover due
C901090038
to queue
C901090039 MSC-controlled incoming handover success time

200 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Counter ID What It Counts


due to queue
Number of MSC-controlled incoming handover
C901090040
success due to queue
Number of incoming handover attempts from the
C901090041
same layer and frequency
Number of incoming handover success from the
C901090042
same layer and frequency
Number of outgoing handover attempts to the
C901090043
same layer and frequency
Number of outgoing handover success to the same
C901090044
layer and frequency
Number of incoming handover attempts from
C901090045
undefined layer to the same frequency
Number of incoming handover success from
C901090046
undefined layer to the same frequency
Number of outgoing handover attempts from
C901090047
undefined layer to the same frequency
Number of outgoing handover success from
C901090048
undefined layer to the same frequency
Number of incoming handover attempts from
C901090049 undefined layer (GSM900) to current layer
(GSM1800)
Number of outgoing handover attempts from
C901090052 current layer (GSM900) to undefined layer
(GSM1800)
Number of outgoing handover from current layer
C901090053
(GSM900) to undefined layer (GSM1800)
Number of outgoing handover success from current
C901090054
layer (GSM900) to undefined layer (GSM1800)
Number of incoming handover attempts from
C901090055 undefined layer (GSM1800) to current layer
(GSM900)
Number of outgoing handover attempts from
C901090058 undefined layer (GSM1800) to current layer
(GSM900)
Number of outgoing handover from undefined layer
C901090059
(GSM1800) to current layer (GSM900)
Number of outgoing handover success from
C901090060 undefined layer (GSM1800) to current layer
(GSM900)
Number of incoming handover attempts from upper
C901090061
layer to the same frequency
Number of incoming handover success from upper
C901090062
layer to the same frequency
Number of outgoing handover attempts from the
C901090063
same frequency to upper layer

Confidential and Proprietary Information of ZTE CORPORATION 201


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter ID What It Counts


Number of outgoing handover success from the
C901090064
same frequency to upper layer
Number of incoming handover attempts from lower
C901090065
layer to the same frequency
Number of incoming handover success from lower
C901090066
layer to the same frequency
Number of outgoing handover attempts from the
C901090067
same frequency to lower layer
Number of outgoing handover success from the
C901090068
same frequency to lower layer
Number of incoming handover attempts from the
C901090069
same layer GSM900 to GSM1800
Number of outgoing handover attempts to the
C901090072
same layer GSM900 to GSM1800
Number of outgoing handover to the same layer
C901090073
GSM900 to GSM1800
Number of outgoing handover success to the same
C901090074
layer GSM900 to GSM1800
Number of incoming handover attempts from
C901090075
GSM900 to GSM1800 from the upper layer
Number of outgoing handover attempts from
C901090078
GSM900 to GSM1800 to the upper layer
Number of outgoing handover from GSM900 to
C901090079
GSM1800 to the upper layer
Number of outgoing handover success from
C901090080
GSM900 to GSM1800 to the upper layer
Number of incoming handover attempts from
C901090081
GSM900 to GSM1800 from the lower layer
Number of outgoing handover attempts from
C901090084
GSM900 to GSM1800 from the lower layer
Number of outgoing handover from GSM900 to
C901090085
GSM1800 in the lower layer
Number of outgoing handover success from
C901090086
GSM900 to GSM1800 in the lower layer
Number of incoming handover attempts from
C901090087
GSM1800 to GSM900 from the same layer
Number of outgoing handover attempts from
C901090090
GSM1800 to GSM900 from the same layer
Number of outgoing handover from GSM1800 to
C901090091
GSM900 from the same layer
Number of outgoing handover success from
C901090092
GSM1800 to GSM900 from the same layer
Number of incoming handover attempts from
C901090093
GSM1800 to GSM900 from the upper layer
C901090096 Number of outgoing handover attempts from

202 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Counter ID What It Counts


GSM1800 to GSM900 to the upper layer
Number of outgoing handover from GSM1800 to
C901090097
GSM900 to the upper layer
Number of outgoing handover success from
C901090098
GSM1800 to GSM900 to the upper layer
Number of incoming handover attempts from
C901090099
GSM1800 to GSM900 from the lower layer
Number of outgoing handover attempts from
C901090102
GSM1800 to GSM900 to the lower layer
Number of outgoing handover from GSM1800 to
C901090103
GSM900 to the lower layer
Number of outgoing handover success from
C901090104
GSM1800 to GSM900 to the lower layer
C901090105 Number of intra-cell handover attempts
Number of intra-cell inner-circle-to-outer-circle
C901090108
handover attempts
Number of intra-cell inner-circle-to-outer-circle
C901090109
handover success
Number of intra-cell outer-circle-to-inner-circle
C901090110
handover attempts
Number of intra-cell outer-circle-to-inner-circle
C901090111
handover success
Number of intra-cell inner-circle-to-inner-circle
C901090112
handover attempts
Number of intra-cell inner-circle-to-inner-circle
C901090113
handover success
Number of intra-cell outer-circle-to-outer-circle
C901090114
handover attempts
Number of intra-cell outer-circle-to-outer-circle
C901090115
handover success
C901090116 Number of handover attempts from 2G to 3G
C901090117 Number of handover from 2G to 3G
C901090118 Number of handover success from 2G to 3G
C901090119 Number of handover attempts from 3G to 2G
C901090120 Number of handover from 3G to 2G
C901090121 Number of handover success from 3G to 2G
Number of intra-cell handover attempts from
C901090122
TCH/F
C901090123 Number of intra-cell TCH/F-to-TCH/F handover
Number of intra-cell TCH/F-to-TCH/F handover
C901090124
success
C901090125 Number of intra-cell TCH/F-to-TCH/H handover

Confidential and Proprietary Information of ZTE CORPORATION 203


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter ID What It Counts


Number of intra-cell TCH/F-to-TCH/H handover
C901090126
success
Number of intra-cell handover attempts from
C901090127
TCH/H
C901090128 Number of intra-cell TCH/H-to-TCH/F handover
Number of intra-cell TCH/H-to-TCH/F handover
C901090129
success
C901090130 Number of intra-cell TCH/H-to-TCH/H handover
Number of intra-cell TCH/H-to-TCH/H handover
C901090131
success
C901090132 Number of inter-cell handover attempts from TCH/F
C901090133 Number of inter-cell TCH/F-to-TCH/F handover
Number of inter-cell TCH/F-to-TCH/F handover
C901090134
success
C901090135 Number of inter-cell TCH/F-to-TCH/H handover
Number of inter-cell TCH/F-to-TCH/H handover
C901090136
success
Number of inter-cell handover attempts from
C901090137
TCH/H
C901090138 Number of inter-cell TCH/H-to-TCH/F handover
Number of inter-cell TCH/H-to-TCH/F handover
C901090139
success
C901090140 Number of inter-cell TCH/H-to-TCH/H handover
Number of inter-cell TCH/H-to-TCH/H handover
C901090141
success
C901090142 Total dual-band outgoing handover attempts
C901090145 Number of dual band incoming handover attempts
C901090148 Number of intra-cell invalid handovers
Number of BSC-controlled inter-cell incoming
C901090149 handover attempts due to forced release
(emergency service)
Number of BSC-controlled inter-cell incoming
C901090150
handover (forced release) (emergency service)
Number of BSC-controlled inter-cell incoming
C901090151 handover attempts due to forced handover
(emergency service)
Number of BSC-controlled inter-cell incoming
C901090152
handover (forced handover) (emergency service)
Number of BSC-controlled inter-cell incoming
C901090153 handover attempts due to queue (emergency
service)
Number of BSC-controlled inter-cell incoming
C901090154
handover (queue) (emergency service)

204 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Counter ID What It Counts


Number of MSC-controlled incoming handover
C901090155 attempts due to forced release (emergency
service)
Number of MSC-controlled incoming handover
C901090156
(forced release) (emergency service)
Number of MSC-controlled inter-cell incoming
C901090157 handover attempts due to forced handover
(emergency service)
Number of MSC-controlled incoming handover
C901090158
(forced release) (emergency service)
Number of MSC-controlled incoming handover
C901090159
attempts due to queue (emergency service)
Number of MSC-controlled incoming handover
C901090160
(queue) (emergency service)
Number of forced handover target not found (BSC-
C901090161 controlled inter-cell handover due to forced
handover)
Number of send forced handover request to lower
C901090162 PRI user (BSC-controlled inter-cell handover due to
forced handover)
Number of recv failure from lower PRI user request
C901090163 resource for forced handover (BSC-controlled inter-
cell handover due to forced handover)
Number of lower PRI user handover failure (BSC-
C901090164 controlled inter-cell handover due to forced
handover)
Number of high PRI user time out for wait resource
C901090165 (BSC-controlled inter-cell handover due to forced
handover)
Number of forced release target not found (BSC-
C901090166 controlled inter-cell handover due to forced
release)
Number of high PRI user time out for wait resource
C901090167 (BSC-controlled inter-cell handover due to forced
release)
Number of HO Target not found (MSC-controlled
C901090168
incoming handover due to forced handover)
Number of send forced handover request to lower
C901090169 PRI user (MSC-controlled incoming handover due
to forced handover)
Number of failure to lower PRI user request
C901090170 resource for forced handover (MSC-controlled
incoming handover due to forced handover)
Number of lower PRI user handover failure (MSC-
C901090171 controlled incoming handover due to forced
handover)

C901090172 Number of high PRI user time out for wait resource
(MSC-controlled incoming handover due to forced

Confidential and Proprietary Information of ZTE CORPORATION 205


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter ID What It Counts


handover)
Number of forced release target not found (MSC-
C901090173 controlled incoming handover due to forced
release)
Number of high PRI user time out for wait resource
C901090174 (MSC-controlled incoming handover due to forced
release)
Number of get before grab released channel
C901090175
(assignment forced handover)
Number of get before grab released channel
C901090176
(assignment forced release)
Number of handover attempts due to eMLPP forced
C901090177
handover
C901090178 Number of handover due to eMLPP forced handover
Number of handover success due to eMLPP forced
C901090179
handover

C901090001
Definition Number of BSC-controlled inter-cell outgoing handover attempts
Description This counter counts the Number of BSC-controlled inter-cell
outgoing handover attempts originated from the source cell by
MS.
Usage This counter is used to find out the frequency of intra-BSC inter-
cell outgoing handover. It is one of the parameters to measure
the wireless environment.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary
and the current attempt cells are intra-BSC, the counter
increments. The measurement point is A, as shown in Figure 108.

206 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

FIGURE 108 – BSC-CONTROLLED INTER-CELL OUTGOING HANDOVER


ATTEMPT
BTS(Src BTS(Target BSC(Target
MS MSC
) ) Inst)
MEAS_RES Handover decision
MEAS_RES
succeeds
A
CHL_ACT
CHL_ACT_ACK

HO_CMD
HO_CMD
HO_ACCESS HO
DETECT
Phy Info
SABM EST_IND
UA
HO_COM
HO_COM

HO_PERFOR
M

Unit Times

C901090004
Definition Number of MSC-controlled outgoing handover attempts
Description This counter counts the number of MSC-controlled inter-BSC
outgoing handover attempts originated from the source cell by
MS.
Usage This counter is used to find out the frequency of MSC-controlled
inter-BSC outgoing handover attempts. It is one of the
parameters to measure the wireless environment.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary
and the current attempt cells are governed by different BSCs,
the source BSC will send MSC the handover request A_HO_RQD
to trigger inter-BSC handover, and the counter increments. The
measurement point is A, as shown in Figure 109.

Confidential and Proprietary Information of ZTE CORPORATION 207


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FI G U R E 1 0 9 – M S C - C O N T RO L L E D OU T G OI N G H AN D O V E R AT T E M P T S

Unit Times

C901090005
Definition Number of MSC-controlled outgoing handover request failures
due to unclear factors
Description This counter counts the number of MSC-controlled inter-BSC
outgoing handover request failures due to unclear factors
originated from the source cell by MS.
Usage This counter is used to find out the frequency of MSC-controlled
outgoing handover request failures due to unclear reasons, and
to find out the MSC-originated handover status.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary
and the current attempt cells are governed by different BSCs,
the source BSC will send MSC the handover request A_HO_RQD
to trigger inter-BSC handover. If BSC fails to receive any
feedback from MSC before the protection timer expires, the
counter increments. The measurement point is A, as shown in
Figure 110.

FIGURE 110 – MSC-CONTROLLED OUTGOING HANDOVER REQUEST FAILURES


DUE TO UNCLEAR FACTORS

BTS BSC MSC

MEAS_RESULT
Handover decision
succeeds
HO_RQD
Handover protection timer is
timeout
A

208 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Unit Times

C901090006
Definition Number of MSC-controlled outgoing handover request failures
due to unavailable ground resource
Description This counter counts the number of MSC-controlled inter-BSC
outgoing handover request failures due to unavailable ground
resource originated from the source cell by MS.
Usage This counter is used to find out the frequency of MSC-controlled
outgoing handover request failures due to unavailable ground
resource, and to find out the MSC-originated handover status.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary
and the current attempt cells are governed by different BSCs,
the source BSC will send MSC the handover request A_HO_RQD
to trigger inter-BSC handover. If the source BSC receives the
feedback from MSC that the handover request is rejected due to
unavailable ground resource, the counter increments. The
measurement point is A, as shown in Figure 111.

FIGURE 111 – MSC-CONTROLLED HANDOVER REQUEST FAILURES

Unit Times

C901090007
Definition Number of MSC-controlled outgoing request failures due to
unavailable radio resource
Description This counter counts the number of MSC-controlled inter-BSC
outgoing handover request failures due to unavailable radio
resource originated from the source cell by MS.
Usage This counter is used to find out the frequency of MS-originated
MSC-controlled outgoing handover request failures due to
unavailable radio resource, and to find out the MSC-originated
handover status.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary

Confidential and Proprietary Information of ZTE CORPORATION 209


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

and the current attempt cells are governed by different BSCs,


the source BSC will send MSC the handover request A_HO_RQD
to trigger inter-BSC handover. If the source BSC receives the
feedback from MSC that the handover request is rejected due to
unavailable radio resource, the counter increments. The
measurement point is A, as shown in Figure 111.
Unit Times

C901090008
Definition Number of MSC-controlled outgoing handover request failures
due to other factors
Description This counter counts the number of MSC-controlled inter-BSC
outgoing handover request failures due to other factors
excluding unavailable ground resource and unavailable radio
resource originated from the source cell by MS.
Usage This counter is used to find out the frequency of MS-originated
MSC-controlled outgoing handover request failures due to other
factors, and to find out the MSC-originated handover status.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary
and the current attempt cells are governed by different BSCs,
the source BSC will send MSC the handover request A_HO_RQD
to trigger inter-BSC handover. If the source BSC receives the
feedback from MSC that the handover request is rejected due to
other factors, the counter increments. The measurement point is
A, as shown in Figure 111.
Unit Times

C901090011
Definition Number of BSC-controlled inter-cell incoming handover attempts
Description This counter counts the Number of BSC-controlled inter-cell
incoming handover attempts from MS to target cell.
Usage This counter is used to find out the frequency of intra-BSC inter-
cell incoming handover attempts originated by MS. It is one of
the parameters to measure the wireless environment.
Measurement When intra-BSC target cell receives the channel request from
Point the source cell, if the request is due to inter-cell handover, the
counter increments. The measurement point is A, as shown in
Figure 112.

210 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

FIGURE 112 – BSC-CONTROLLED INTER-CELL INCOMING HANDOVER


ATTEMPTS

BTS BSC

MEAS_ RESULT Handover


decision
succeeds
Inter-cell handover
attempt
A

Unit Times

C901090013
Definition Number of BSC-controlled incoming handover attempts due to
forced release
Description This counter counts the number of forced release attempts
originated by target cell due to unavailable radio resource during
the process of MS-originated BSC-controlled inter-cell incoming
handover. When target instance fails to allocate the channel,
forced release attempts could be originated referring to the MS
priority and MSC & BSC settings.
Usage This counter is used to find out the frequency of MS-originated
BSC-controlled inter-cell incoming handover attempts due to
forced release, which reflects the handover status.
Measurement When intra-BSC target cell receives the wireless channel
Point application request, if the application cause is BSC-controlled
inter-cell incoming handover and wireless channel is unavailable
to target cell, forced release attempt decision starts. If forced
release attempt is feasible, the counter increments before the
target cell sends forced release message to the instance that is
to be released. The measurement point is A, as shown in Figure
113.

FIGURE 113 – FORCED RELEASE ATTEMPTS

BSC BTS

MEAS_ RESULT
Handover decision succeeds
No available channel, forced
handover is attempted
A CHL_ ACTIV

CHL_ ACTIV_ ACK

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 211


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901090015
Definition Number of BSC-controlled incoming handover attempts due to
queue
Description This counter counts the number of queuing attempts originated
by target cell due to unavailable radio resource during the
process of MS-originated BSC-controlled inter-cell incoming
handover.
Usage This counter is used to find out the frequency of MS-originated
BSC-controlled inter-cell incoming handover attempts due to
queue, which reflects the handover status.
Measurement When intra-BSC target cell receives the wireless channel
Point application request, if the application cause is BSC-controlled
inter-cell incoming handover and wireless channel is unavailable
to target cell, queuing attempt decision starts. If queuing
attempt is feasible and the target cell has the target instance
waiting in the queuing, the counter increments. The
measurement point is A, as shown in Figure 114.

FIGURE 114 – QUEUING ATTEMPTS

BSC BTS

MEAS_ RESULT
Handover decision succeeds,
no available channel
Enter queue to wait for
resource
A
CHL_ ACTIV
CHL_ ACTIV_ ACK

Unit Times

C901090017
Definition Number of BSC-controlled incoming handover attempts due to
forced handover
Description This counter counts the number of forced-handover attempts
originated by target cell due to unavailable radio resource during
the process of MS-originated BSC-controlled inter-cell incoming
handover.
Usage This counter is used to find out the frequency of MS-originated
BSC-controlled inter-cell incoming handover attempts due to
forced handover, which reflects the handover status.
Measurement When intra-BSC target cell receives the wireless channel
Point application request, if the application cause is BSC-controlled
inter-cell incoming handover and wireless channel is unavailable

212 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

to target cell, forced-handover attempt decision starts. If forced-


handover attempt is feasible, the counter increments before the
target cell sends forced-handover message to the instance that
is to be forced. The measurement point is A, as shown in Figure
115.

FIGURE 115 – FORCED-HANDOVER ATTEMPTS

BSC BTS

MEAS_ RESULT
Handover decision succeeds, no
available channel
Forced handover is
attempted
A
CHL_ ACTIV
CHL_ ACTIV_ ACK

Unit Times

C901090020
Definition BSC-controlled incoming handover time due to queue
Description This counter counts the total time of call queuing that participate
in BSC-controlled intra-cell incoming handover due to queue.
Queuing time refers to a period of an instance from entering to
quitting the queuing.
Usage This counter is used to find out the total time of BSC-controlled
intra-cell incoming handover due to queue, which helps to
understand the traffic status and the situation of the queuing for
resource.
Measurement „ Under the condition that database acquires resource via
Point dynamic channel conversion or MS releases resource and
queuing instance receives usable message, if the application
cause is BSC-controlled incoming handover, the queuing time
accumulates. The measurement point is A, as shown in
Figure 116.

FIGURE 116 – EXECUTION IN QUEUING

BSC BTS

MEAS_ RESULT
Handover decision succeeds, no
available channel
Enter queue to wait for resource,
resource is available
A
CHL_ ACTIV
CHL_ ACTIV_ ACK

Confidential and Proprietary Information of ZTE CORPORATION 213


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

„ If the instance queuing timer expires, and the application


cause is BSC-controlled incoming handover, the queuing time
accumulates. The measurement point is A, as shown in
Figure 117.

FIGURE 117 – INCOMING HANDOVER QUEUING EXPIRES

„ During the process of instance queuing, when the instance is


released due to some causes, if the application cause is BSC-
controlled incoming handover, the queuing time accumulates.
The measurement point is A, as shown in Figure 118.

FIGURE 118 – INSTANCE RELEASE DURING QUEUING

Unit Second

C901090021
Definition Number of BSC-controlled incoming handover due to queue
Description This counter counts the total number of calls that participate in
BSC-controlled intra-cell incoming handover due to queue.
Usage This counter is used to find out the total number of calls that
participate in BSC-controlled intra-cell incoming handover due to
queue, which helps to understand the traffic status.
Measurement „ Under the condition that database acquires resource via
Point dynamic channel conversion or MS releases resource and

214 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

queuing instance receives usable message, if the application


cause is BSC-controlled incoming handover, the counter
increments. The measurement point is A, as shown in Figure
116.
„ If the instance queuing timer expires, and the application
cause is BSC-controlled incoming handover, the counter
increments. The measurement point is A, as shown in Figure
117.
„ During the process of instance queuing, when the instance is
released due to certain causes, if the application cause is
BSC-controlled incoming handover, the counter increments.
The measurement point is A, as shown in Figure 118.
Unit Times

C901090022
Definition BSC-controlled incoming handover success time due to queue
Description This counter counts the total time of calls that participate in
successful BSC-controlled intra-cell incoming handover due to
queue and acquiring resource.
Usage This counter is used to find out the total queuing time of calls
that participate in successful BSC-controlled intra-cell incoming
handover due to queue and acquiring resource, and to find out
the valid queuing time.
Measurement Under the condition that database acquires resource via dynamic
Point channel conversion or MS releases resource, when queuing
instance receives resource usable message, if the application
cause is BSC-controlled incoming handover, the queuing time
accumulates. The measurement point is A, as shown in Figure
116.
Unit Second

C901090023
Definition Number of BSC-controlled incoming handover success due to
queue
Description This counter counts the total number of calls that participate in
BSC-controlled intra-cell incoming handover due to queue and
successfully acquiring resource.
Usage This counter is used to find out the total number of calls that
participate in BSC-controlled intra-cell incoming handover due to
queue and successfully acquiring resource, and to find out the
success ratio of queuing.
Measurement Under the condition that database acquires resource via dynamic
Point channel conversion or MS releases resource and queuing

Confidential and Proprietary Information of ZTE CORPORATION 215


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

instance receives resource usable message, if the application


cause is BSC-controlled incoming handover, the counter
increments. The measurement point is A, as shown in Figure 116.
Unit Times

C901090024
Definition Number of MSC-controlled incoming handover attempts
Description This counter counts the number of MSC-originated inter-BSC
incoming handover attempts.
Usage This counter is used to find out the frequency of MSC-originated
inter-BSC incoming handover attempts. It is one of the
parameters to measure the wireless environment.
Measurement When the target cell receives the channel application, if the
Point application cause is external incoming handover, the counter
increments. The measurement point is A, as shown in Figure 119.

FIGURE 119 – MSC-CONTROLLED INCOMING HANDOVER ATTEMPTS

Unit Times

C901090025
Definition Number of incoming handover failure due to circuit block
Description This counter counts the number of unsuccessful MSC-originated
inter-BSC incoming handover due to ground circuit block.
Usage This counter is used to find out the frequency of unsuccessful
MSC-originated inter-BSC incoming handover due to ground
circuit block, and is used to observe the external handover flow.
Measurement When the target cell receives the handover request from MSC, it
Point checks the ground circuit. If the requested ground circuit is
blocked, the counter increments. The measurement point is A,
as shown in Figure 120.

216 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

FIGURE 120 – UNSUCCESSFUL MSC-CONTROLLED EXTERNAL INCOMING


HANDOVER

Unit Times

C901090026
Definition Number of incoming handover failure due to circuit group
mismatch
Description This counter counts the number of unsuccessful MSC-originated
inter-BSC incoming handover due to ground circuit group
mismatch.
Usage This counter is used to find out the frequency of unsuccessful
MSC-originated inter-BSC incoming handover due to ground
circuit group mismatch, and is used to observe the external
handover flow.
Measurement When the target cell receives the handover request from MSC, it
Point checks the ground circuit. If the requested ground circuit does
not match, the counter increments. The measurement point is A,
as shown in Figure 120.
Unit Times

C901090027
Definition Number of incoming handover failure requests due to
unavailable radio resource
Description This counter counts the number of unsuccessful MSC-originated
inter-BSC incoming handover due to unavailable radio resource.
Usage This counter is used to find out the frequency of unsuccessful
MSC-originated inter-BSC incoming handover due to unavailable
radio resource, and is used to observe the external handover
flow.
Measurement When the target cell receives the handover request from MSC, it
Point allocates the wireless channels and attempts to activate and
connect. If one link fails and the target cell sends MSC the
handover failure message, the counter increments. The
measurement point is A, as shown in Figure 120.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 217


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901090028
Definition Number of incoming handover failure due to other factors
Description This counter counts the number of unsuccessful MSC-originated
inter-BSC incoming handover due to other factors excluding
circuit block, circuit group mismatch and unavailable radio
resource.
Usage This counter is used to find out the frequency of unsuccessful
MSC-originated inter-BSC incoming handover due to other
factors, and is used to observe the external handover flow.
Measurement When the target cell receives the handover request from MSC, it
Point sends MSC the handover failure message. If the failure is due to
other factors, the counter increments. The measurement point is
A, as shown in Figure 120.
Unit Times

C901090030
Definition Number of MSC-controlled incoming handover attempts due to
forced release
Description This counter counts the number of forced release attempts
originated by target cell due to unavailable radio resource during
the process of MS-originated MSC-controlled inter-BSC incoming
handover. When target instance fails to allocate the channel,
forced release attempts could be originated referring to the MS
priority and MSC & BSC settings.
Usage This counter is used to find out the frequency of MS-originated
MSC-controlled inter-BSC incoming handover attempts due to
forced release, which reflects the handover status.
Measurement When the target cell receives the wireless channel application
Point request, if the application cause is MSC-controlled inter-BSC
incoming handover and wireless channel is unavailable to target
cell, forced release attempt decision starts. If forced release
attempt is feasible, the counter increments before the target cell
sends forced release message to the instance that is to be force-
released. The measurement point is A, as shown in Figure 113.
Unit Times

C901090032
Definition Number of MSC-controlled incoming handover attempts due to
queue
Description This counter counts the number of queuing attempts originated
by target cell due to unavailable radio resource during the

218 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

process of MS-originated MSC-controlled inter-BSC incoming


handover.
Usage This counter is used to find out the frequency of MS-originated
MSC-controlled inter-BSC incoming handover attempts due to
queue, which reflects the handover status.
Measurement When the target cell receives the wireless channel application
Point request, if the application cause is MSC-controlled inter-BSC
incoming handover and wireless channel is unavailable to target
cell, queuing attempt decision starts. If queuing attempt is
feasible, the target cell has the target instance waiting in the
queuing, and the counter increments. The measurement point is
A, as shown in Figure 114.
Unit Times

C901090034
Definition Number of MSC-controlled incoming handover attempts due to
forced handovers
Description This counter counts the number of forced-handover attempts
originated by target cell due to unavailable radio resource during
the process of MS-originated MSC-controlled inter-BSC incoming
handover.
Usage This counter is used to find out the frequency of MS-originated
MSC-controlled inter-BSC incoming handover attempts due to
forced handover, which reflects the handover status.
Measurement When the target cell receives the wireless channel application
Point request, if the application cause is MSC-controlled inter-BSC
incoming handover and wireless channel is unavailable to target
cell, forced-handover attempt decision starts. If forced-handover
attempt is feasible, the counter increments before the target cell
sends forced-handover message to the instance that is to be
forced handover. The measurement point is A, as shown in
Figure 115.
Unit Times

C901090037
Definition MSC-controlled incoming handover time due to queue
Description This counter counts the total time of call queuing that participate
in MSC-controlled intra-cell incoming handover due to queue.
Usage This counter is used to find out the total time of MSC-controlled
intra-cell incoming handover due to queue, which helps to
understand the traffic status and the situation of the queuing for
resource.

Confidential and Proprietary Information of ZTE CORPORATION 219


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement „ Under the condition that database acquires resource via


Point dynamic channel conversion or MS releases resource, and
queuing instance receives usable message, if the application
cause is MSC-controlled incoming handover, the queuing
time accumulates. The measurement point is A, as shown in
Figure 116.
„ If the instance queuing timer expires, and the application
cause is MSC-controlled incoming handover, the queuing
time accumulates. The measurement point is A, as shown in
Figure 117.
„ During the process of instance queuing, when the instance is
released due to some causes, if the application cause is MSC-
controlled incoming handover, the queuing time accumulates.
The measurement point is A, as shown in Figure 118.
Unit Second

C901090038
Definition Number of MSC-controlled incoming handover due to queue
Description This counter counts the total number of calls that participate in
BSC-controlled intra-cell incoming handover due to queue.
Usage This counter is used to find out the total number of calls that
participate in MSC-controlled intra-cell incoming handover due to
queue, which helps to understand the traffic status.
Measurement • Under the condition that database acquires resource via
Point dynamic channel conversion or MS releases resource, and
queuing instance receives usable message, if the application
cause is MSC-controlled incoming handover, the counter
increments. The measurement point is A, as shown in Figure
116.
„ If the instance queuing timer expires, and the application
cause is MSC-controlled incoming handover, the counter
increments. The measurement point is A, as shown in Figure
117.
„ During the process of instance queuing, when the instance is
released due to some causes, if the application cause is MSC-
controlled incoming handover, the counter increments. The
measurement point is A, as shown in Figure 118.
Unit Times

C901090039
Definition MSC-controlled incoming handover success time due to queue

220 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Description This counter counts the total time of calls that participate in
successful MSC-controlled intra-cell incoming handover due to
queue and acquiring resource.
Usage This counter is used to find out the total queuing time of calls
that participate in successful MSC-controlled intra-cell incoming
handover due to queue and acquiring resource, and to find out
the valid queuing time.
Measurement Under the condition that database acquires resource via dynamic
Point channel conversion or MS releases resource, when queuing
instance receives resource usable message, if the application
cause is MSC-controlled incoming handover, the queuing time
accumulates. The measurement point is A, as shown in Figure
116.
Unit Second

C901090040
Definition Number of MSC-controlled incoming handover success due to
queue
Description This counter counts the total number of calls that participate in
MSC-controlled intra-cell incoming handover due to queue and
successfully acquires resource.
Usage This counter is used to find out the total number of calls that
participate in MSC-controlled intra-cell incoming handover due to
queue and successfully acquires resource, and to find out the
success ratio of queuing.
Measurement Under the condition that database acquires resource via dynamic
Point channel conversion or MS releases resource, and queuing
instance receives resource usable message, if the application
cause is MSC-controlled incoming handover, the counter
increments. The measurement point is A, as shown in Figure 116.
Unit Times

C901090041
Definition Number of incoming handover attempts from the same layer and
frequency
Description This counter counts the number of BSC-controlled inter-cell
incoming handover attempts the target cell receives from the
same layer and frequency.
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover attempts from the same layer and frequency,
which helps to make the network planning.
Measurement When intra-BSC target cell receives the channel application
Point request from the source cell, if the application cause is inter-cell

Confidential and Proprietary Information of ZTE CORPORATION 221


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

incoming handover and the source cell is at the same layer and
frequency, the counter increments. The measurement point is A,
as shown in Figure 112.
Unit Times

C901090042
Definition Number of incoming handover success from the same layer and
frequency
Description This counter counts the number of successful BSC-controlled
inter-cell incoming handover the target cell receives from the
same layer and frequency.
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover success from the same layer and frequency,
and is used to observe the handover flow.
Measurement When intra-BSC target cell receives the handover completed
Point message, if the application cause is BSC-controlled inter-cell
handover and the source cell is at the same layer and frequency,
the counter increments. The measurement point is A, as shown
in Figure 121.

FIGURE 121 – SUCCESSFUL BSC-CONTROLLED INTER-CELL INCOMING


HANDOVER

Unit Times

C901090043
Definition Number of outgoing handover attempts to the same layer and
frequency
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover attempts the target cell sends to the same
layer and frequency.
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts to the same layer and frequency,
which helps to make the network planning.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are BSC-controlled internal cells at

222 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

the same layer and frequency, the counter increments. The


measurement point is A, as shown in Figure 108.
Unit Times

C901090044
Definition Number of outgoing handover success to the same layer and
frequency
Description This counter counts the number of successful BSC-controlled
inter-cell outgoing handover the target cell sends to the same
layer and frequency.
Usage This counter is used to find out the frequency of successful BSC-
controlled outgoing handover to the same layer and frequency,
which helps to make the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point receives the handover completed message from the target cell,
and the target cell is at the same layer and frequency, the
counter increments. The measurement point is A, as shown in
Figure 122.

FIGURE 122 – SUCCESSFUL BSC-CONTROLLED INTER-CELL OUTGOING


HANDOVER

Unit Times

C901090045
Definition Number of incoming handover attempts from undefined layer to
the same frequency
Description This counter counts the number of BSC-controlled inter-cell
incoming handover attempts the target cell receives from
undefined layer to the same frequency.
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover attempts from undefined layer to the same
frequency, which helps to make the network planning.
Measurement When intra-BSC target cell receives the channel application
Point request from the source cell, if the application cause is inter-cell
incoming handover and the source cell is at the undefined layer
and the same frequency, the counter increments. The
measurement point is A, as shown in Figure 112.

Confidential and Proprietary Information of ZTE CORPORATION 223


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Unit Times

C901090046
Definition Number of incoming handover success from undefined layer to
the same frequency
Description This counter counts the number of successful BSC-controlled
inter-cell incoming handover the target cell receives from
undefined layer to the same frequency.
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover success from undefined layer to the same
frequency, which helps to observe the handover flow.
Measurement When intra-BSC target cell receives the handover completed
Point message, if the application cause is BSC-controlled inter-cell
handover, and the source cell is at undefined layer and the same
frequency, the counter increments. The measurement point is A,
as shown in Figure 121.
Unit Times

C901090047
Definition Number of outgoing handover attempts from undefined layer to
the same frequency
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover attempts the source cell sends from
undefined layer to the same frequency.
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from undefined layer to the same
frequency, which helps to make the network planning.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are BSC-controlled internal cells at
undefined layer and the same frequency, the counter increments.
The measurement point is A, as shown in Figure 108.
Unit Times

C901090048
Definition Number of outgoing handover success from undefined layer to
the same frequency
Description This counter counts the number of successful BSC-controlled
inter-cell outgoing handover the source cell sends from
undefined layer to the same frequency.

224 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Usage This counter is used to find out the frequency of successful BSC-
controlled outgoing handover from undefined layer to the same
frequency, which helps to make the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point receives the handover completed message from the target cell,
and the target cell is at undefined layer and the same frequency,
the counter increments. The measurement point is A, as shown
in Figure 122.
Unit Times

C901090049
Definition Number of incoming handover attempts from undefined layer
(GSM900) to current layer (GSM1800)
Description This counter counts the number of BSC-controlled inter-cell
incoming handover attempts the target cell (GSM1800) receives
from undefined layer (GSM900).
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover attempts from undefined layer (GSM900) to
current layer (GSM1800), which helps to make the network
planning.
Measurement When intra-BSC target cell (GSM1800) receives the channel
Point application request from the source cell (GSM900), if the
application cause is inter-cell incoming handover and the source
cell is at undefined layer, the counter increments. The
measurement point is A, as shown in Figure 112.
Unit Times

C901090052
Definition Number of outgoing handover attempts from current layer
(GSM900) to undefined layer (GSM1800)
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover attempts the source cell (GSM900) sends to
undefined layer (GSM1800).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from undefined layer (GSM900) to
current layer (GSM1800), which helps to make the network
planning.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are BSC-controlled internal cells at
undefined layer (GSM1800) and the current serving cell is
GSM900, the counter increments. The measurement point is A,
as shown in Figure 108.

Confidential and Proprietary Information of ZTE CORPORATION 225


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Unit Times

C901090053
Definition Number of outgoing handover from current layer (GSM900) to
undefined layer (GSM1800)
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover the source cell (GSM900) sends to undefined
layer (GSM1800).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from undefined layer (GSM900) to
current layer (GSM1800), which helps to make the network
planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM900) receives the radio resource unavailable message from
the target cell (GSM1800), and the target cell is at undefined
layer and the same frequency, the counter increments. The
measurement point is A, as shown in Figure 123.

FIGURE 123 – BSC-CONTROLLED INTER-CELL OUTGOING HANDOVER


EXECUTION FLOW

Unit Times

C901090054
Definition Number of outgoing handover success from current layer
(GSM900) to undefined layer (GSM1800)
Description This counter counts the number of successful BSC-controlled
inter-cell outgoing handover the source cell (GSM900) sends
from undefined layer to the same frequency (GSM1800).
Usage This counter is used to find out the frequency of successful BSC-
controlled outgoing handover from undefined layer to the same
frequency (GSM900) to current layer (GSM1800), which helps to
make the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM900) receives the handover completed message from the
target cell (GSM1800), and the target cell is at undefined layer
and the same frequency, the counter increments. The
measurement point is A, as shown in Figure 122.

226 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Unit Times

C901090055
Definition Number of incoming handover attempts from undefined layer
(GSM1800) to current layer (GSM900)
Description This counter counts the number of BSC-controlled inter-cell
incoming handover attempts the target cell (GSM900) receives
from undefined layer (GSM1800).
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover attempts from undefined layer (GSM1800) to
current layer (GSM900), which helps to make the network
planning.
Measurement When intra-BSC target cell (GSM900) receives the channel
Point application request from the source cell (GSM1800), if the
application cause is inter-cell incoming handover and the source
cell is at undefined layer, the counter increments. The
measurement point is A, as shown in Figure 112.
Unit Times

C901090058
Definition Number of outgoing handover attempts from undefined layer
(GSM1800) to current layer (GSM900)
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover attempts the source cell (GSM1800) sends to
undefined layer (GSM900).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from undefined layer (GSM1800) to
current layer (GSM900), which helps to make the network
planning.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempted cell is BSC-controlled internal cell at
undefined layer (GSM900) or lower-layer cell at same frequency
(GSM1800), the counter increments. The measurement point is
A, as shown in Figure 108.
Unit Times

C901090059
Definition Number of outgoing handover from undefined layer (GSM1800)
to current layer (GSM900)

Confidential and Proprietary Information of ZTE CORPORATION 227


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of BSC-controlled inter-cell


outgoing handover the source cell (GSM1800) sends to
undefined layer (GSM900).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from undefined layer (GSM1800) to
current layer (GSM900), which helps to make the network
planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM1800) receives the radio resource unavailable message
from the target cell (GSM900), and the target cell is at
undefined layer and the same frequency, the counter increments.
The measurement point is A, as shown in Figure 123.
Unit Times

C901090060
Definition Number of outgoing handover success from undefined layer
(GSM1800) to current layer (GSM900)
Description This counter counts the number of successful BSC-controlled
inter-cell outgoing handover the source cell (GSM1800) sends
from undefined layer to the same frequency (GSM900).
Usage This counter is used to find out the frequency of successful BSC-
controlled outgoing handover from undefined layer to the same
frequency (GSM1800) to current layer (GSM900), which helps to
make the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM1800) receives the handover completed message from the
target cell (GSM900), and the target cell is at undefined layer
and the same frequency, the counter increments. The
measurement point is A, as shown in Figure 122.
Unit Times

C901090061
Definition Number of incoming handover attempts from upper layer to the
same frequency
Description This counter counts the number of BSC-controlled inter-cell
incoming handover attempts the target cell receives from upper
layer to the same frequency.
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover attempts from upper layer to the same
frequency, which helps to make the network planning.
Measurement When intra-BSC target cell receives the channel application
Point request from the source cell, if the application cause is inter-cell
incoming handover and the source cell is at upper layer and the

228 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

same frequency, the counter increments. The measurement


point is A, as shown in Figure 112.
Unit Times

C901090062
Definition Number of incoming handover success from upper layer to the
same frequency
Description This counter counts the number of successful BSC-controlled
inter-cell incoming handover the target cell receives from upper
layer to the same frequency.
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover success from upper layer to the same
frequency, and is used to observe the handover flow.
Measurement When intra-BSC target cell receives the handover completed
Point message, if the application cause is BSC-controlled inter-BSC
handover and the source cell is at upper and the same frequency,
the counter increments. The measurement point is A, as shown
in Figure 121.
Unit Times

C901090063
Definition Number of outgoing handover attempts from the same
frequency to upper layer
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover attempts the source cell sends from upper
layer to the same frequency.
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from upper layer to the same
frequency, which helps to make the network planning.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are BSC-controlled internal cells at
upper layer and the same frequency, the counter increments.
The measurement point is A, as shown in Figure 108.
Unit Times

C901090064
Definition Number of outgoing handover success from the same frequency
to upper layer

Confidential and Proprietary Information of ZTE CORPORATION 229


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of successful BSC-controlled


inter-cell outgoing handover the source cell sends from upper
layer to the same frequency.
Usage This counter is used to find out the frequency of successful BSC-
controlled outgoing handover from upper layer to the same
frequency, which helps to make the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point receives the handover completed message from the target cell,
it means that MS has accessed the target channel, handover
successful. If the target cell is at upper layer and the same
frequency, the counter increments. The measurement point is A,
as shown in Figure 122.
Unit Times

C901090065
Definition Number of incoming handover attempts from lower layer to the
same frequency
Description This counter counts the number of BSC-controlled inter-cell
incoming handover attempts the target cell receives from lower
layer to the same frequency.
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover attempts from lower layer to the same
frequency, which helps to make the network planning.
Measurement When intra-BSC target cell receives the channel application
Point request from the source cell, if the application cause is inter-cell
incoming handover and the source cell is at lower layer and the
same frequency, the counter increments. The measurement
point is A, as shown in Figure 112.
Unit Times

C901090066
Definition Number of incoming handover success from lower layer to the
same frequency
Description This counter counts the number of successful BSC-controlled
inter-cell incoming handover the target cell receives from lower
layer to the same frequency.
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover success from lower layer to the same
frequency, and is used to observe the handover flow.
Measurement When intra-BSC target cell receives the handover completed
Point message, if the application cause is BSC-controlled inter-BSC
handover and the source cell is at lower and the same frequency,

230 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

the counter increments. The measurement point is A, as shown


in Figure 121.
Unit Times

C901090067
Definition Number of outgoing handover attempts from the same
frequency to lower layer
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover attempts the source cell sends from the
same frequency to lower layer.
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from the same frequency to lower
layer, which helps to make the network planning.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are BSC-controlled internal cells at
lower layer and the same frequency, the counter increments.
The measurement point is A, as shown in Figure 108.
Unit Times

C901090068
Definition Number of outgoing handover success from the same frequency
to lower layer
Description This counter counts the number of successful BSC-controlled
inter-cell outgoing handover the source cell sends from the same
frequency to lower layer.
Usage This counter is used to find out the frequency of successful BSC-
controlled outgoing handover from the same frequency to lower
layer, which helps to make the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point receives the handover completed message from the target cell,
and the target cell is at lower layer and the same frequency, the
counter increments. The measurement point is A, as shown in
Figure 122.
Unit Times

C901090069
Definition Number of incoming handover attempts from the same layer
GSM900 to GSM1800
Description

Confidential and Proprietary Information of ZTE CORPORATION 231


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This counter counts the number of BSC-controlled inter-cell


incoming handover attempts the target cell (GSM1800) receives
from the same layer (GSM900).
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover attempts from the same layer GSM900 to
GSM1800, which helps to make the network planning.
Measurement When intra-BSC target cell (GSM1800) receives the channel
Point application request from the source cell (GSM900), if the
application cause is inter-cell handover and the source cell is at
the same layer, the counter increments. The measurement point
is A, as shown in Figure 112.
Unit Times

C901090072
Definition Number of outgoing handover attempts to the same layer
GSM900 to GSM1800
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover attempts the source cell (GSM900) sends to
the same layer (GSM1800).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts to the same layer GSM900 to
GSM1800, which helps to make the network planning.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are BSC-controlled internal cells at
the same layer (GSM1800) and the current serving cell is
GSM900, the counter increments. The measurement point is A,
as shown in Figure 108.
Unit Times

C901090073
Definition Number of outgoing handover to the same layer GSM900 to
GSM1800
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover the source cell (GSM900) sends to the same
layer (GSM1800).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts to the same layer GSM900 to
GSM1800, which helps to make the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM900) receives the radio resource unavailable message from
the target cell (GSM1800), and the target cell is at the same

232 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

layer and frequency, the counter increments. The measurement


point is A, as shown in Figure 123.
Unit Times

C901090074
Definition Number of outgoing handover success to the same layer
GSM900 to GSM1800
Description This counter counts the number of successful BSC-controlled
inter-cell outgoing handover the source cell (GSM900) sends to
the same layer and frequency (GSM1800).
Usage This counter is used to find out the frequency of successful BSC-
controlled outgoing handover to the same layer and frequency
from GSM900 to GSM1800, which helps to make the network
planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM900) receives the handover completed message from the
target cell (GSM1800), and the target cell is at the same layer
and frequency, the counter increments. The measurement point
is A, as shown in Figure 122.
Unit Times

C901090075
Definition Number of incoming handover attempts from GSM900 to
GSM1800 from the upper layer
Description This counter counts the number of BSC-controlled inter-cell
incoming handover attempts the target cell (GSM1800) receives
from upper layer (GSM900).
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover attempts at upper layer and from GSM900 to
GSM1800, which helps to make the network planning.
Measurement When intra-BSC target cell (GSM1800) receives the channel
Point application request from the source cell (GSM900), if the
application cause is inter-cell handover and the source cell is at
upper layer, the counter increments. The measurement point is
A, as shown in Figure 112.
Unit Times

C901090078
Definition Number of outgoing handover attempts from GSM900 to
GSM1800 to the upper layer

Confidential and Proprietary Information of ZTE CORPORATION 233


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of BSC-controlled inter-cell


outgoing handover attempts the source cell (GSM900) sends to
upper layer (GSM1800).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from GSM900 to GSM1800 to the
upper layer, which helps to make the network planning.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are BSC-controlled internal cells at
upper layer (GSM1800) and the current serving cell is GSM900,
the counter increments. The measurement point is A, as shown
in Figure 108.
Unit Times

C901090079
Definition Number of outgoing handover from GSM900 to GSM1800 to the
upper layer
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover the source cell (GSM900) sends to upper
layer (GSM1800).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from GSM900 to GSM1800 to the
upper layer, which helps to make the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM900) receives the radio resource unavailable message from
the target cell (GSM1800), and the target cell is at upper layer
and the same frequency, the counter increments. The
measurement point is A, as shown in Figure 123.
Unit Times

C901090080
Definition Number of outgoing handover success from GSM900 to
GSM1800 to the upper layer
Description This counter counts the number of successful BSC-controlled
inter-cell outgoing handover the source cell (GSM900) sends
from upper layer to the same frequency (GSM1800).
Usage This counter is used to find out the frequency of successful BSC-
controlled outgoing handover from upper layer to the same
frequency from GSM900 to GSM1800, which helps to make the
network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM900) receives the handover completed message from the
target cell (GSM1800), and the target cell is at upper layer and

234 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

the same frequency, the counter increments. The measurement


point is A, as shown in Figure 122.
Unit Times

C901090081
Definition Number of incoming handover attempts from GSM900 to
GSM1800 from the lower layer
Description This counter counts the number of BSC-controlled inter-cell
incoming handover attempts the target cell (GSM1800) receives
from lower layer (GSM900).
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover attempts at lower layer and from GSM900 to
GSM1800, which helps to make the network planning.
Measurement When intra-BSC target cell (GSM1800) receives the channel
Point application request from the source cell (GSM900), if the
application cause is inter-cell handover and the source cell is at
lower layer, the counter increments. The measurement point is A,
as shown in Figure 112.
Unit Times

C901090084
Definition Number of outgoing handover attempts from GSM900 to
GSM1800 from the lower layer
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover attempts the source cell (GSM900) sends to
lower layer (GSM1800).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts to lower layer and from GSM900 to
GSM1800, which helps to make the network planning.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are BSC-controlled internal cells at
lower layer (GSM1800) and the current serving cell is GSM900,
the counter increments. The measurement point is A, as shown
in Figure 108.
Unit Times

C901090085
Definition Number of outgoing handover from GSM900 to GSM1800 in the
lower layer

Confidential and Proprietary Information of ZTE CORPORATION 235


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of BSC-controlled inter-cell


outgoing handover the source cell (GSM900) sends to lower
layer (GSM1800).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts to lower layer and from GSM900 to
GSM1800, which helps to make the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM900) receives the radio resource unavailable message from
the target cell (GSM1800), and the target cell is at lower layer
and the same frequency, the counter increments. The
measurement point is A, as shown in Figure 123.
Unit Times

C901090086
Definition Number of outgoing handover success from GSM900 to
GSM1800 in the lower layer
Description This counter counts the number of successful BSC-controlled
inter-cell outgoing handover the source cell (GSM900) sends
from the same frequency to lower layer (GSM1800).
Usage This counter is used to find out the frequency of successful BSC-
controlled outgoing handover from the same frequency to lower
layer from GSM900 to GSM1800, which helps to make the
network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM900) receives the handover completed message from the
target cell (GSM1800), and the target cell is at lower layer and
the same frequency, the counter increments. The measurement
point is A, as shown in Figure 122.
Unit Times

C901090087
Definition Number of incoming handover attempts from GSM1800 to
GSM900 from the same layer
Description This counter counts the number of BSC-controlled inter-cell
incoming handover attempts the target cell (GSM900) receives
from the same layer (GSM1800).
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover attempts at the same layer and from
GSM1800 to GSM900, which helps to make the network planning.
Measurement When intra-BSC target cell (GSM900) receives the channel
Point application request from the source cell (GSM1800), if the
application cause is inter-cell handover and the source cell is at

236 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

the same layer, the counter increments. The measurement point


is A, as shown in Figure 112.
Unit Times

C901090090
Definition Number of outgoing handover attempts from GSM1800 to
GSM900 from the same layer
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover attempts the source cell (GSM1800) sends to
the same layer (GSM900).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts to the same layer and from
GSM1800 to GSM900, which helps to make the network planning.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are BSC-controlled internal cells at
the same layer (GSM900) and the current serving cell is
GSM1800, the counter increments. The measurement point is A,
as shown in Figure 108.
Unit Times

C901090091
Definition Number of outgoing handover from GSM1800 to GSM900 from
the same layer
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover the source cell (GSM1800) sends to the same
layer (GSM900).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts to the same layer and from
GSM1800 to GSM900, which helps to make the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM1800) receives the radio resource unavailable message
from the target cell (GSM900), and the target cell is at the same
layer and frequency, the counter increments. The measurement
point is A, as shown in Figure 123.
Unit Times

C901090092
Definition Number of outgoing handover success from GSM1800 to
GSM900 from the same layer

Confidential and Proprietary Information of ZTE CORPORATION 237


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of successful BSC-controlled


inter-cell outgoing handover the source cell (GSM1800) sends to
the same layer and frequency (GSM900).
Usage This counter is used to find out the frequency of successful BSC-
controlled outgoing handover to the same layer and frequency
and from GSM1800 to GSM900, which helps to make the
network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM1800) receives the handover completed message from the
target cell (GSM900), and the target cell is at the same layer
and frequency, the counter increments. The measurement point
is A, as shown in Figure 122.
Unit Times

C901090093
Definition Number of incoming handover attempts from GSM1800 to
GSM900 from the upper layer
Description This counter counts the number of BSC-controlled inter-cell
incoming handover attempts the target cell (GSM900) receives
from upper layer (GSM1800).
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover attempts at upper layer and from GSM1800
to GSM900, which helps to make the network planning.
Measurement When intra-BSC target cell (GSM900) receives the channel
Point application request from the source cell (GSM1800), if the
application cause is inter-cell handover and the source cell is at
upper layer, the counter increments. The measurement point is
A, as shown in Figure 112.
Unit Times

C901090096
Definition Number of outgoing handover attempts from GSM1800 to
GSM900 to the upper layer
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover attempts the source cell (GSM1800) sends to
upper layer (GSM900).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from GSM1800 to GSM900 to the
upper layer, which helps to make the network planning.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are BSC-controlled internal cells at
upper layer (GSM900) and the current serving cell is GSM1800,

238 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

the counter increments. The measurement point is A, as shown


in Figure 108.
Unit Times

C901090097
Definition Number of outgoing handover from GSM1800 to GSM900 to the
upper layer
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover the source cell (GSM1800) sends to upper
layer (GSM900).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from GSM1800 to GSM900 to the
upper layer, which helps to make the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM1800) receives the radio resource unavailable message
from the target cell (GSM900), and the target cell is at upper
layer and the same frequency, the counter increments. The
measurement point is A, as shown in Figure 123.
Unit Times

C901090098
Definition Number of outgoing handover success from GSM1800 to
GSM900 to the upper layer
Description This counter counts the number of successful BSC-controlled
inter-cell outgoing handover the source cell (GSM1800) sends
from upper layer to the same frequency (GSM900).
Usage This counter is used to find out the frequency of successful BSC-
controlled outgoing handover from upper layer to the same
frequency and from GSM1800 to GSM900, which helps to make
the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM1800) receives the handover completed message from the
target cell (GSM900), and the target cell is at upper layer and
the same frequency, the counter increments. The measurement
point is A, as shown in Figure 122.
Unit Times

C901090099
Definition Number of incoming handover attempts from GSM1800 to
GSM900 from the lower layer

Confidential and Proprietary Information of ZTE CORPORATION 239


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of BSC-controlled inter-cell


incoming handover attempts the target cell (GSM900) receives
from lower layer (GSM1800).
Usage This counter is used to find out the frequency of BSC-controlled
incoming handover attempts from GSM1800 to GSM900 from
the lower layer, which helps to make the network planning.
Measurement When intra-BSC target cell (GSM900) receives the channel
Point application request from the source cell (GSM1800), if the
application cause is inter-cell handover and the source cell is at
lower layer, the counter increments. The measurement point is A,
as shown in Figure 112.
Unit Times

C901090102
Definition Number of outgoing handover attempts from GSM1800 to
GSM900 to the lower layer
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover attempts the source cell (GSM1800) sends to
lower layer (GSM900).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from GSM1800 to GSM900 to the
lower layer, which helps to make the network planning.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are BSC-controlled internal cells at
lower layer (GSM900) and the current serving cell is GSM1800,
the counter increments. The measurement point is A, as shown
in Figure 108.
Unit Times

C901090103
Definition Number of outgoing handover from GSM1800 to GSM900 to the
lower layer
Description This counter counts the number of BSC-controlled inter-cell
outgoing handover the source cell (GSM1800) sends to lower
layer (GSM900).
Usage This counter is used to find out the frequency of BSC-controlled
outgoing handover attempts from GSM1800 to GSM900 to the
lower layer, which helps to make the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM1800) receives the radio resource unavailable message
from the target cell (GSM900), and the target cell is at lower

240 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

layer and the same frequency, the counter increments. The


measurement point is A, as shown in Figure 123.
Unit Times

C901090104
Definition Number of outgoing handover success from GSM1800 to
GSM900 to the lower layer
Description This counter counts the number of successful BSC-controlled
inter-cell outgoing handover the source cell (GSM1800) sends
from the same frequency to lower layer (GSM900).
Usage This counter is used to find out the frequency of successful BSC-
controlled outgoing handover from the same frequency from
GSM1800 to GSM900 to the lower layer, which helps to make
the network planning.
Measurement During the process of BSC-controlled handover, if the source cell
Point (GSM1800) receives the handover completed message from the
target cell (GSM900), and the target cell is at lower layer and
the same frequency, the counter increments. The measurement
point is A, as shown in Figure 122.
Unit Times

C901090105
Definition Number of intra-cell handover attempts
Description This counter counts the number of intra-cell handover attempts
originated from the source cell by MS.
Usage This counter is used to find out the frequency of intra-cell
handover attempts. It is one of the parameters to measure the
wireless environment.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If intra-cell handover is necessary,
the counter increments. The measurement point is A, as shown
in Figure 124.

FIGURE 124 – INTRA-CELL HANDOVER ATTEMPT

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 241


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901090108
Definition Number of intra-cell inner-circle-to-outer-circle handover
attempts
Description This counter counts the number of inner-circle-to-outer-circle
handover attempts originated by MS when configuring the sub
cell.
Usage This counter is used to find out the frequency of inter-sub cell
inner-circle-to-outer-circle handover attempts. It is one of the
parameters to measure the sub cell operation status.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inner-circle-to-outer-circle
handover is necessary, the counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C901090109
Definition Number of intra-cell inner-circle-to-outer-circle handover
success
Description This counter counts the number of successful inner-circle-to-
outer-circle handovers originated by MS when configuring the
sub cell.
Usage This counter is used to find out the frequency of successful inter-
sub cell inner-circle-to-outer-circle handovers.
Measurement During handover, if the source instance receives the handover
Point completed message from the target instance, and the application
cause is inner-circle-to-outer-circle handover, the counter
increments. The measurement point is A, as shown in Figure 125.

FIGURE 125 – SUCCESSFUL INTRA-CELL HANDOVER

Unit Times

C901090110
Definition Number of intra-cell outer-circle-to-inner-circle handover
attempts

242 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Description This counter counts the number of outer-circle-to-inner-circle


handover attempts originated by MS when configuring the sub
cell.
Usage This counter is used to find out the frequency of inter-sub cell
outer-circle-to-inner-circle handover attempts. It is one of the
parameters to measure the sub cell operation status.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If outer-circle-to-inner-circle
handover is necessary, the counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C901090111
Definition Number of intra-cell outer-circle-to-inner-circle handover
success
Description This counter counts the number of successful outer-circle-to-
inner-circle handovers originated by MS when configuring the
sub cell.
Usage This counter is used to find out the frequency of successful inter-
sub cell outer-circle-to-inner-circle handovers, and is to find out
the success ratio of intra-sub cell handovers.
Measurement During handover, if the source instance receives the handover
Point completed message from the target instance, and the application
cause is outer-circle-to-inner-circle handover, the counter
increments. The measurement point is A, as shown in Figure 125.
Unit Times

C901090112
Definition Number of intra-cell inner-circle-to-inner-circle handover
attempts
Description This counter counts the number of inner-circle-to-inner-circle
handover attempts originated by MS when configuring the sub
cell.
Usage This counter is used to find out the frequency of inter-sub cell
inner-circle-to-inner-circle handover attempts. It is one of the
parameters to measure the sub cell operation status.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inner-circle-to-inner-circle
handover is necessary, the counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 243


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901090113
Definition Number of intra-cell inner-circle-to-inner-circle handover success
Description This counter counts the number of successful inner-circle-to-
inner-circle handovers originated by MS when configuring the
sub cell.
Usage This counter is used to find out the frequency of successful inter-
sub cell inner-circle-to-inner-circle handovers.
Measurement During handover, if the source instance receives the handover
Point completed message from the target instance, and the application
cause is inner-circle-to-inner-circle handover, the counter
increments. The measurement point is A, as shown in Figure 125.
Unit Times

C901090114
Definition Number of intra-cell outer-circle-to-outer-circle handover
attempts
Description This counter counts the number of outer-circle-to-outer-circle
handover attempts originated by MS when configuring the sub
cell.
Usage This counter is used to find out the frequency of inter-sub cell
outer-circle-to-outer-circle handover attempts. It is one of the
parameters to measure the sub cell operation status.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If outer-circle-to-outer-circle
handover is necessary, the counter increments. The
measurement point is A, as shown in Figure 124.
Unit Times

C901090115
Definition Number of intra-cell outer-circle-to-outer-circle handover
success
Description This counter counts the number of successful outer-circle-to-
outer-circle handovers originated by MS when configuring the
sub cell.
Usage This counter is used to find out the frequency of successful inter-
sub cell outer-circle-to-outer-circle handovers.
Measurement During handover, if the source instance receives the handover
Point completed message from the target instance, and the application
cause is outer-circle-to-outer-circle handover, the counter
increments. The measurement point is A, as shown in Figure 125.

244 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Unit Times

C901090116
Definition Number of handover attempts from 2G to 3G
Description This counter counts the number of inter-system 2G to 3G
handover attempts originated by MS.
Usage This counter is used to find out the frequency of handover
attempts from 2G to 3G. It is one of the parameters to measure
the wireless environment.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are 3G cells, BSC sends MSC the
handover request message A_HO_RQD, the counter increments.
The measurement point is A, as shown in Figure 109.
Unit Times

C901090117
Definition Number of handover from 2G to 3G
Description This counter counts the number of inter-system 2G to 3G
handover originated by MS.
Usage This counter is used to find out the frequency of handover from
2G to 3G. It is one of the parameters to measure the wireless
environment.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are 3G cells, BSC sends MSC the
handover request message A_HO_RQD to trigger the inter-BSC
handover. If BSC receives the handover command returned from
MSC, the counter increments. The measurement point is A, as
shown in Figure 126.

FIGURE 126 – MSC-CONTROLLED OUTGOING HANDOVER

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 245


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901090118
Definition Number of handover success from 2G to 3G
Description This counter counts the number of successful inter-system 2G to
3G handovers originated by MS.
Usage This counter is used to find out the frequency of handover
success from 2G to 3G. It is one of the parameters to measure
the wireless environment.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,
and the current attempt cells are governed by various BSCs,
BSC sends MSC the handover request message A_HO_RQD to
trigger the inter-BSC handover. If MS accesses the target 3G cell
successfully and the source 2G cell receives the release
command from MSC, the counter increments. The measurement
point is A, as shown in Figure 127.

FIGURE 127 – SUCCESSFUL MSC-CONTROLLED OUTGOING HANDOVER

BSC MSC

CLEAR_CMD

Unit Times

C901090119
Definition Number of handover attempts from 3G to 2G
Description This counter counts the number of inter-system 3G to 2G
handover attempts originated by MS.
Usage This counter is used to find out the frequency of handover
attempts from 3G to 2G. It is one of the parameters to measure
the wireless environment.
Measurement When 2G cell receives the channel application request, if the
Point application cause is external incoming handover and the source
cell is 3G cell, the counter increments. The measurement point is
A, as shown in Figure 119.
Unit Times

C901090120
Definition Number of handover from 3G to 2G

246 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Description This counter counts the number of inter-system 3G to 2G


outgoing handover originated by MS.
Usage This counter is used to find out the frequency of handover from
3G to 2G. It is one of the parameters to measure the wireless
environment.
Measurement When 2G cell receives the channel handover request from MSC,
Point if the channel is successfully allocated and activated, and the
source cell is 3G cell, the counter increments. The measurement
point is A, as shown in Figure 128.

FIGURE 128 – MSC-CONTROLLED INCOMING HANDOVER

Unit Times

C901090121
Definition Number of handover success from 3G to 2G
Description This counter counts the number of successful inter-system 3G to
2G incoming handover originated by MS.
Usage This counter is used to find out the frequency of handover
success from 3G to 2G. It is one of the parameters to measure
the wireless environment.
Measurement When 2G cell receives the handover completed message, if the
Point application cause is MSC-controlled inter-BSC incoming
handover and the source cell is 3G cell, the counter increments.
The measurement point is A, as shown in Figure 129.

FIGURE 129 – MSC-CONTROLLED INCOMING HANDOVER SUCCESS

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 247


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901090122
Definition Number of intra-cell handover attempts from TCH/F
Description This counter counts the number of intra-cell incoming handover
attempts from TCH/F originated by MS.
Usage This counter is used to find out the frequency of intra-cell
incoming handover attempts from TCH/F. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is intra-cell handover, and the source channel
is TCH/F, the counter increments. The measurement point is A,
as shown in Figure 130.

FIGURE 130 – INTRA-CELL INCOMING HANDOVER ATTEMPT

Unit Times

C901090123
Definition Number of intra-cell TCH/F-to-TCH/F handover
Description This counter counts the number of intra-cell TCH/F-to-TCH/F
incoming handover originated by MS.
Usage This counter is used to find out the frequency of intra-cell
TCH/F-to-TCH/F incoming handover attempts. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is intra-cell handover, and the source channel
is TCH/F; if the new channel is successfully applied and activated,
the counter increments. The measurement point is A, as shown
in Figure 131.

FIGURE 131 – INTRA-CELL INCOMING HANDOVER

Unit Times

248 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

C901090124
Definition Number of intra-cell TCH/F-to-TCH/F handover success
Description This counter counts the number of successful intra-cell TCH/F-
to-TCH/F incoming handover originated by MS.
Usage This counter is used to find out the frequency of successful intra-
cell TCH/F-to-TCH/F incoming handover. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is intra-cell handover, and the source channel
is TCH/F; if MS successfully accesses the new channel and the
new channel is TCH/F, the counter increments. The
measurement point is A, as shown in Figure 132.

FIGURE 132 – SUCCESSFUL INTRA-CELL HANDOVER

Unit Times

C901090125
Definition Number of intra-cell TCH/F-to-TCH/H handover
Description This counter counts the number of intra-cell TCH/F-to-TCH/H
incoming handover originated by MS.
Usage This counter is used to find out the frequency of intra-cell
TCH/F-to-TCH/H incoming handover attempts. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is intra-cell handover, and the source channel
is TCH/H; if the new channel is successfully applied and
activated, the counter increments. The measurement point is A,
as shown in Figure 131.
Unit Times

C901090126
Definition Number of intra-cell TCH/F-to-TCH/H handover success
Description This counter counts the number of successful intra-cell TCH/F-
to-TCH/H incoming handover originated by MS.

Confidential and Proprietary Information of ZTE CORPORATION 249


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Usage This counter is used to find out the frequency of successful intra-
cell TCH/F-to-TCH/H incoming handover. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is intra-cell handover, and the source channel
is TCH/F; if MS successfully accesses the new channel and the
new channel is TCH/H, the counter increments. The
measurement point is A, as shown in Figure 132.
Unit Times

C901090127
Definition Number of intra-cell handover attempts from TCH/H
Description This counter counts the number of intra-cell incoming handover
attempts from TCH/H originated by MS.
Usage This counter is used to find out the frequency of intra-cell
incoming handover attempts from TCH/H. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is intra-cell handover, and the source channel
is TCH/H, the counter increments. The measurement point is A,
as shown in Figure 130.
Unit Times

C901090128
Definition Number of intra-cell TCH/H-to-TCH/F handover
Description This counter counts the number of intra-cell TCH/H-to-TCH/F
incoming handover originated by MS.
Usage This counter is used to find out the frequency of intra-cell
TCH/H-to-TCH/F incoming handover attempts. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is intra-cell handover, and the source channel
is TCH/H; if the new channel is successfully applied and
activated and the new channel is TCH/F, the counter increments.
The measurement point is A, as shown in Figure 131.
Unit Times

C901090129
Definition Number of intra-cell TCH/H-to-TCH/F handover success

250 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Description This counter counts the number of successful intra-cell TCH/H-


to-TCH/F incoming handover originated by MS.
Usage This counter is used to find out the frequency of successful intra-
cell TCH/H-to-TCH/F incoming handover. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is intra-cell handover, and the source channel
is TCH/H; if MS successfully accesses the new channel and the
new channel is TCH/F, the counter increments. The
measurement point is A, shown in Figure 132.
Unit Times

C901090130
Definition Number of intra-cell TCH/H-to-TCH/H handover
Description This counter counts the number of intra-cell TCH/H-to-TCH/H
incoming handover originated by MS.
Usage This counter is used to find out the frequency of intra-cell
TCH/H-to-TCH/H incoming handover attempts. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is intra-cell handover, and the source channel
is TCH/H; if the new channel is successfully applied and
activated and the new channel is TCH/H, the counter increments.
The measurement point is A, as shown in Figure 131.
Unit Times

C901090131
Definition Number of intra-cell TCH/H-to-TCH/H handover success
Description This counter counts the number of successful intra-cell TCH/H-
to-TCH/H incoming handover originated by MS.
Usage This counter is used to find out the frequency of successful intra-
cell TCH/H-to-TCH/H incoming handover. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is intra-cell handover, and the source channel
is TCH/H; if MS successfully accesses the new channel and the
new channel is TCH/H, the counter increments. The
measurement point is A, as shown in Figure 132.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 251


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901090132
Definition Number of inter-cell handover attempts from TCH/F
Description This counter counts the number of inter-cell incoming handover
attempts from TCH/F originated by MS.
Usage This counter is used to find out the frequency of inter-cell
incoming handover attempts from TCH/F. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is inter-cell handover, and the source channel
is TCH/F, the counter increments. The measurement point is A,
as shown in Figure 112.
Unit Times

C901090133
Definition Number of inter-cell TCH/F-to-TCH/F handover
Description This counter counts the number of inter-cell TCH/F-to-TCH/F
incoming handover originated by MS.
Usage This counter is used to find out the frequency of inter-cell
TCH/F-to-TCH/F incoming handover attempts. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is inter-cell handover, and the source channel
is TCH/F; if the new channel is successfully applied and activated,
the counter increments. The measurement point is A, as shown
in Figure 112.
Unit Times

C901090134
Definition Number of inter-cell TCH/F-to-TCH/F handover success
Description This counter counts the number of successful inter-cell TCH/F-
to-TCH/F incoming handover originated by MS.
Usage This counter is used to find out the frequency of successful inter-
cell TCH/F-to-TCH/F incoming handover. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is inter-cell handover, and the source channel
is TCH/F; if MS successfully accesses the new channel and the
new channel is TCH/F, the counter increments. The
measurement point is A, as shown in Figure 133.

252 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

FIGURE 133 – BSC-CONTROLLED INTER-CELL INCOMING HANDOVER

Unit Times

C901090135
Definition Number of inter-cell TCH/F-to-TCH/H handover
Description This counter counts the number of inter-cell TCH/F-to-TCH/H
incoming handover originated by MS.
Usage This counter is used to find out the frequency of inter-cell
TCH/F-to-TCH/H incoming handover attempts. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is inter-cell handover, and the source channel
is TCH/F; if the new channel is successfully applied and activated
and the new channel is TCH/H, the counter increments. The
measurement point is A, as shown in Figure 112.
Unit Times

C901090136
Definition Number of inter-cell TCH/F-to-TCH/H handover success
Description This counter counts the number of successful inter-cell TCH/F-
to-TCH/H incoming handover originated by MS.
Usage This counter is used to find out the frequency of successful inter-
cell TCH/F-to-TCH/H incoming handover. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is inter-cell handover, and the source channel
is TCH/F; if MS successfully accesses the new channel and the
new channel is TCH/H, the counter increments. The
measurement point is A, as shown in Figure 133.
Unit Times

C901090137
Definition Number of inter-cell handover attempts from TCH/H

Confidential and Proprietary Information of ZTE CORPORATION 253


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of inter-cell incoming handover


attempts from TCH/H originated by MS.
Usage This counter is used to find out the frequency of inter-cell
incoming handover attempts from TCH/H. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is inter-cell handover, and the source channel
is TCH/H, the counter increments. The measurement point is A,
as shown in Figure 112.
Unit Times

C901090138
Definition Number of inter-cell TCH/H-to-TCH/F handover
Description This counter counts the number of inter-cell TCH/H-to-TCH/F
incoming handover originated by MS.
Usage This counter is used to find out the frequency of inter-cell
TCH/H-to-TCH/F incoming handover attempts. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is inter-cell handover, and the source channel
is TCH/H; if the new channel is successfully applied and
activated and the new channel is TCH/F, the counter increments.
The measurement point is A, as shown in Figure 112.
Unit Times

C901090139
Definition Number of inter-cell TCH/H-to-TCH/F handover success
Description This counter counts the number of successful inter-cell TCH/H-
to-TCH/F incoming handover originated by MS.
Usage This counter is used to find out the frequency of successful inter-
cell TCH/H-to-TCH/F incoming handover. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is inter-cell handover, and the source channel
is TCH/H; if MS successfully accesses the new channel and the
new channel is TCH/F, the counter increments. The
measurement point is A, as shown in Figure 133.
Unit Times

254 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

C901090140
Definition Number of inter-cell TCH/H-to-TCH/H handover
Description This counter counts the number of inter-cell TCH/H-to-TCH/H
incoming handover originated by MS.
Usage This counter is used to find out the frequency of inter-cell
TCH/H-to-TCH/H incoming handover attempts. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is inter-cell handover, and the source channel
is TCH/H; if the new channel is successfully applied and
activated and the new channel is TCH/H, the counter increments.
The measurement point is A, as shown in Figure 112.
Unit Times

C901090141
Definition Number of inter-cell TCH/H-to-TCH/H handover success
Description This counter counts the number of successful inter-cell TCH/H-
to-TCH/H incoming handover originated by MS.
Usage This counter is used to find out the frequency of successful inter-
cell TCH/H-to-TCH/H incoming handover. It is one of the
parameters to measure the wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is inter-cell handover, and the source channel
is TCH/H; if MS successfully accesses the new channel and the
new channel is TCH/H, the counter increments. The
measurement point is A, as shown in Figure 133.
Unit Times

C901090142
Definition Total dual band outgoing handover attempts
Description This counter counts the number of MSC-controlled inter-BSC
(the source cell and the target cell are at different bands)
outgoing handover attempts originated from the source cell by
MS.
Usage This counter is used to find out the frequency of MSC-controlled
inter-BSC (the source cell and the target cell are at different
bands) outgoing handover attempts. It is one of the parameters
to measure the wireless environment.
Measurement BSC starts the handover decision after it receives the
Point measurement report from MS. If inter-cell handover is necessary,

Confidential and Proprietary Information of ZTE CORPORATION 255


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

and the current attempt cells are governed by different BSCs,


BSC will send MSC the handover request A_HO_RQD to trigger
inter-BSC handover. If the source cell and the target cell that
are at different bands, the counter increments. The
measurement point is A, as shown in Figure 109.
Unit Times

C901090145
Definition Total dual band incoming handover attempts
Description This counter counts the number of inter-BSC (the source cell and
the target cell are at different bands) incoming handover
attempts originated by MSC.
Usage This counter is used to find out the frequency of inter-BSC (the
source cell and the target cell are at different bands) incoming
handover attempts. It is one of the parameters to measure the
wireless environment.
Measurement When the target cell receives the channel application request, if
Point the application cause is external incoming handover, and the
source cell and the target cell that are at different bands, the
counter increments. The measurement point is A, as shown in
Figure 119.
Unit Times

C901090148
Definition Number of intra-cell invalid handovers
Description This counter counts the number of intra-cell invalid handovers.
Invalid handover refers to that: handovers continue to happen in
a cell where there is UL/DL interference; if the number of the
handovers exceeds the pre-set threshold, intra-cell handover
punishment will be triggered to stop the continuous handovers;
if there is no new interference handover during sending the
measurement report of pre-set number, then the next handover
will be considered valid.
Usage This counter is used to find out the frequency of intra-cell invalid
handover attempts. It is one of the parameters to measure the
wireless environment.
Measurement When BSC receives the channel application request, if the
Point application cause is intra-cell interference handover, and such
interference handover has already occurred in the pre-defined
scope of time, the counter increments. The measurement point
is A, as shown in Figure 130.
Unit Times

256 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

C901090149
Definition Number of BSC-controlled inter-cell incoming handover attempts
due to forced release (emergency service)
Description This counter counts the number of forced release attempts due
to unavailable radio resource in target cell in the process of BSC-
controlled inter-cell incoming handover initiated by a MS on
emergency service. Target instance can initiate forced release
attempt based on MS priority and MSC & BSC settings during
channel allocation failure.
Usage This counter counts the frequency of forced release attempts
occurred during BSC-controlled inter-cell incoming handover
initiated by a MS. It can reflect the handover process.
Measurement Intra-BSC target cell receives radio channel request to
Point determine whether to do forced release attempt if the request
reason is BSC-controlled inter-cell incoming handover and the
target cell has not available radio channel. This counter
increments before target cell sends forced release message to
forced release instance. The measurement point is A shown in
Figure 113.
Unit Times

C901090150
Definition Number of BSC-controlled inter-cell incoming handover (forced
release) (emergency service)
Description This counter counts the number of forced release due to
unavailable radio resource in target cell in the process of BSC-
controlled inter-cell incoming handover initiated by a MS on
emergency service.
Usage This counter counts the frequency of forced release occurred
during BSC-controlled inter-cell incoming handover initiated by a
MS. It can reflect the handover process.
Measurement Intra-BSC target cell receives radio channel request to do forced
Point release if the request reason is BSC-controlled inter-cell
incoming handover and the target cell has not available radio
channel. This counter increments if target cell receives available
resource message sent from forced instance. The measurement
point is A, as shown in Figure 134.

Confidential and Proprietary Information of ZTE CORPORATION 257


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 134 - BSC-CONTROLLED FORCED RELEASE ON INCOMING HANDOVER

Unit Times

C901090151
Definition Number of BSC-controlled inter-cell incoming handover attempts
due to forced handover (emergency service)
Description This counter counts the number of forced handover attempts
due to unavailable radio resource in target cell in the process of
BSC-controlled inter-cell incoming handover initiated by a MS on
emergency service.
Usage This counter counts the frequency of forced handover attempts
occurred during BSC-controlled inter-cell incoming handover
initiated by a MS. It can reflect the handover process.
Measurement Intra-BSC target cell receives radio channel request to
Point determine whether to do forced handover attempt if the request
reason is BSC-controlled inter-cell incoming handover and the
target cell has not available radio channel. This counter
increments before target cell sends forced handover message to
forced handover instance. The measurement point is A, as
shown in Figure 115.
Unit Times

C901090152
Definition Number of BSC-controlled inter-cell incoming handover (forced
handover) (emergency service)
Description This counter counts the number of forced handover due to
unavailable radio resource in target cell in the process of BSC-
controlled inter-cell incoming handover initiated by a MS on
emergency service.
Usage This counter counts the frequency of forced handover occurred
during BSC-controlled inter-cell incoming handover initiated by a
MS. It can reflect the handover process.

258 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Measurement Intra-BSC target cell receives radio channel request and adds it
Point into a queue after sending forced handover message to forced
handover instance if the request reason is BSC-controlled inter-
cell incoming handover and the target cell has not available
radio channel. This counter increments if target cell receives
available resource message. The measurement point is A, as
shown in Figure 135.

FIGURE 135 - BSC-CONTROLLED FORCED HANDOVER ON INCOMING


HANDOVER

Unit Times

C901090153
Definition Number of BSC-controlled inter-cell incoming handover attempts
due to queue (emergency service)
Description This counter counts the number of queue attempts due to
unavailable radio resource in target cell in the process of BSC-
controlled inter-cell incoming handover initiated by a MS on
emergency service.
Usage This counter counts the frequency of queue attempts occurred
during BSC-controlled inter-cell incoming handover initiated by a
MS. It can reflect the handover process.
Measurement Intra-BSC target cell receives radio channel request to
Point determine whether to do queue if the request reason is BSC-
controlled inter-cell incoming handover and the target cell has
not available radio channel. This counter increments if target cell
adds target instance into a queue. The measurement point is A,
as shown in Figure 114.
Unit Times

C901090154
Definition Number of BSC-controlled inter-cell incoming handover (queue)
(emergency service)

Confidential and Proprietary Information of ZTE CORPORATION 259


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter counts the number of queue due to unavailable


radio resource in target cell in the process of BSC-controlled
inter-cell incoming handover initiated by a MS on emergency
service.
Usage This counter counts the frequency of queue occurred during
BSC-controlled inter-cell incoming handover initiated by a MS. It
can reflect the handover process.
Measurement Intra-BSC target cell receives radio channel request and adds
Point target instance into a queue if the request reason is BSC-
controlled inter-cell incoming handover and the target cell has
not available radio channel. Thereafter, this counter increments
if target cell receives available resource message. The
measurement point is A, as shown in Figure 136.

FIGURE 136 - BSC-CONTROLLED QUEUE ON INCOMING HANDOVER

Unit Times

C901090155
Definition Number of MSC-controlled incoming handover attempts due to
forced release (emergency service)
Description This counter counts the number of forced release attempts due
to unavailable radio resource in target cell in the process of
MSC-controlled inter-BSC incoming handover initiated by a MS
on emergency service. Target instance can initiate forced release
attempt based on MS priority and MSC & BSC settings during
channel allocation failure.
Usage This counter counts the frequency of forced release attempts
occurred during BSC-controlled inter-BSC incoming handover
initiated by a MS. It can reflect the handover process.
Measurement Target cell receives radio channel request to determine whether
Point to do forced release attempt if the request reason is MSC-
controlled inter-BSC incoming handover and the target cell has
not available radio channel. This counter increments before
target cell sends forced release message to forced release
instance. The measurement point is A shown in Figure 137.

260 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

FIGURE 137 - MSC-CONTROLLED FORCED RELEASE ATTEMPT ON INCOMING


HANDOVER

MSC BSC BTS

HO_REQ
Unavailable channel,
forced release attempt
A CHL_ACTIV

CHL_ACTIV_ACK
HO_REQ_ACK

Unit Times

C901090156
Definition Number of MSC-controlled incoming handover (forced release)
(emergency service)
Description This counter counts the number of forced handover due to
unavailable radio resource in target cell in the process of MSC-
controlled inter-BSC incoming handover initiated by a MS on
emergency service.
Usage This counter counts the frequency of forced handover occurred
during BSC-controlled inter-BSC incoming handover initiated by
a MS. It can reflect the handover process.
Measurement Intra-BSC target cell receives radio channel request and adds it
Point into a queue after sending forced handover message to forced
handover instance if the request reason is MSC-controlled inter-
BSC incoming handover and the target cell has not available
radio channel. This counter increments if target cell receives
available resource message. The measurement point is A, as
shown in Figure 138.

FIGURE 138 - MSC-CONTROLLED FORCED RELEASE ON INCOMING HANDOVER

MSC BSC BTS

HO_REQ
Forced release attempt,
resource available
A CHL_ACTIV

CHL_ACTIV_ACK
HO_REQ_ACK

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 261


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901090157
Definition Number of MSC-controlled inter-cell incoming handover attempts
due to forced handover (emergency service)
Description This counter counts the number of forced handover attempts
due to unavailable radio resource in target cell in the process of
MSC-controlled inter-BSC incoming handover initiated by a MS
on emergency service.
Usage This counter counts the frequency of forced handover attempt
occurred during MSC-controlled inter-BSC incoming handover
initiated by a emergent MS. It can reflect the handover process.
Measurement Target cell receives radio channel request to determine whether
Point to do forced handover attempt if the request reason is MSC-
controlled inter-BSC incoming handover and the target cell has
not available radio channel. This counter increments before
target cell sends forced handover message to forced handover
instance. The measurement point is A, as shown in Figure 139.

FIGURE 139 - MSC-CONTROLLED FORCED HANDOVER ATTEMPT ON INCOMING


HANDOVER

MSC BSC BTS

HO_REQ
Unavailable channel,
forced handover attempt
A CHL_ACTIV

CHL_ACTIV_ACK
HO_REQ_ACK

Unit Times

C901090158
Definition Number of MSC-controlled incoming handover (forced release)
(emergency service)
Description This counter counts the number of forced handover due to
unavailable radio resource in target cell in the process of MSC-
controlled inter-BSC incoming handover initiated by a MS on
emergency service.
Usage This counter counts the frequency of forced handover occurred
during BSC-controlled inter-BSC incoming handover initiated by
a MS. It can reflect the handover process.

262 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

Measurement Intra-BSC target cell receives radio channel request and adds it
Point into a queue after sending forced handover message to forced
handover instance if the request reason is MSC-controlled inter-
BSC incoming handover and the target cell has not available
radio channel. This counter increments if target cell receives
available resource message. The measurement point is A, as
shown in Figure 140.

FIGURE 140 - MSC-CONTROLLED FORCED HANDOVER ON INCOMING


HANDOVER

MSC BSC BTS

HO_REQ
Forced handover attempt,
resource available
A CHL_ACTIV

CHL_ACTIV_ACK
HO_REQ_ACK

Unit Times

C901090159
Definition Number of MSC-controlled incoming handover attempts due to
queue (emergency service)
Description This counter counts the number of queue attempts due to
unavailable radio resource in target cell in the process of MSC-
controlled inter-BSC incoming handover initiated by a MS on
emergency service.
Usage This counter counts the frequency of queue attempts occurred
during BSC-controlled inter-BSC incoming handover initiated by
a MS. It can reflect the handover process.
Measurement Target cell receives radio channel request to determine whether
Point to do a queue if the request reason is MSC-controlled inter-BSC
incoming handover and the target cell has not available radio
channel. This counter increments if target cell adds target
instance into a queue. The measurement point is A, as shown in
Figure 141.

Confidential and Proprietary Information of ZTE CORPORATION 263


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 141 - MSC-CONTROLLED QUEUE ATTEMPT ON INCOMING HANDOVER

MSC BSC BTS

HO_REQ
Unavailable channel,
queue attempt
A CHL_ACTIV

CHL_ACTIV_ACK
HO_REQ_ACK

Unit Times

C901090160
Definition Number of MSC-controlled incoming handover (queue)
(emergency service)
Description This counter counts the number of queue due to unavailable
radio resource in target cell in the process of MSC-controlled
inter-BSC incoming handover initiated by a MS on emergency
service.
Usage This counter counts the frequency of queue occurred during
BSC-controlled inter-BSC incoming handover initiated by a MS.
It can reflect the handover process.
Measurement Target cell receives radio channel request and adds target
Point instance into a queue if the request reason is MSC-controlled
inter-BSC incoming handover and the target cell has not
available radio channel. Thereafter, this counter increments if
target cell receives available resource message. The
measurement point is A, as shown in Figure 142.

FIGURE 142 - MSC-CONTROLLED QUEUE ON INCOMING HANDOVER

MSC BSC BTS

HO_REQ
Queue, resource available

A CHL_ACTIV

CHL_ACTIV_ACK
HO_REQ_ACK

Unit Times

264 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

C901090161
Definition Number of forced handover target not found (BSC-controlled
inter-cell handover due to forced handover)
Description This counter counts the number of forced handover target not
found due to unavailable radio resource in target cell in the
process of BSC-controlled inter-cell incoming handover initiated
by a MS.
Usage This counter counts the frequency of forced handover target not
found during BSC-controlled inter-cell incoming handover
initiated by a MS. It can reflect the handover process.
Measurement Intra-BSC target cell receives radio channel request if the
Point request reason is BSC-controlled inter-cell incoming handover
and the target cell has not available radio channel. This counter
increments if the forced handover target is not found after
initiating forced handover attempt. The measurement point is A,
as shown in Figure 143.

FIGURE 143 - FORCED HANDOVER TARGET NOT FOUND (BSC-CONTROLLED


INTER-CELL HANDOVER DUE TO FORCED HANDOVER)

BSC BTS

MEAS_ RESULT
Handover decision success,
unavailable channel, do forced
handover attempt, and forced
A handover target not found
CHL_ ACTIV
CHL_ ACTIV_ ACK

Unit Times

C901090162
Definition Number of send forced handover request to lower PRI user
(BSC-controlled inter-cell handover due to forced handover)
Description This counter counts the number of sending forced handover
request to lower priority user on forced handover attempt due to
unavailable radio resource in target cell in the process of BSC-
controlled inter-cell incoming handover initiated by a MS.
Usage This counter counts the frequency of sending forced handover
request to a lower priority user during BSC-controlled inter-cell
incoming handover initiated by a MS. It can reflect the handover
process.

Confidential and Proprietary Information of ZTE CORPORATION 265


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement Intra-BSC target cell receives radio channel request if the


Point request reason is BSC-controlled inter-cell incoming handover
and the target cell has not available radio channel. This counter
increments if sending forced handover request to a lower priority
user after initiating forced handover attempt. The measurement
point is A, as shown in Figure 144.

FIGURE 144 - SEND FORCED HANDOVER REQUEST TO LOWER PRI USER (BSC-
CONTROLLED INTER-CELL HANDOVER DUE TO FORCED HANDOVER)

BSC BTS

MEAS_ RESULT
Handover decision success,
unavailable channel, do
forced handover attempt,
and send forced handover
request to a lower priority
A user

CHL_ ACTIV
CHL_ ACTIV_ ACK

Unit Times

C901090163
Definition Number of recv failure from lower PRI user request resource for
forced handover (BSC-controlled inter-cell handover due to
forced handover)
Description This counter counts the number of receiving failure from lower
priority user due to failure of resource while forced handover
attempt is initiated due to unavailable radio resource in target
cell in the process of BSC-controlled inter-cell incoming
handover initiated by a MS.
Usage This counter counts the frequency of receiving failure of forced
handover request from a lower priority user during BSC-
controlled inter-cell incoming handover initiated by a MS. It can
reflect the handover process.
Measurement Intra-BSC target cell receives radio channel request if the
Point request reason is BSC-controlled inter-cell incoming handover
and the target cell has not available radio channel. This counter
increments if receiving failure of forced handover request from a
lower priority user after initiating forced handover attempt. The
measurement point is A, as shown in Figure 145.

266 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

FIGURE 145 - RECV FAILURE FROM LOWER PRI USER REQUEST RESOURCE
FOR FORCED HANDOVER (BSC-CONTROLLED INTER-CELL HANDOVER DUE TO
FORCED HANDOVER)

BSC BTS

MEAS_ RESULT
Handover decision success,
unavailable channel, do
forced handover attempt,
send forced handover
request to a lower priority
user, and receive failure
A of resource request
CHL_ ACTIV
CHL_ ACTIV_ ACK

Unit Times

C901090164
Definition Number of lower PRI user handover failure (BSC-controlled
inter-cell handover due to forced handover)
Description This counter counts the number of receiving failure from lower
priority user due to handover failure while forced handover
attempt is initiated due to unavailable radio resource in target
cell in the process of BSC-controlled inter-cell incoming
handover initiated by a MS.
Usage This counter counts the frequency of receiving handover failure
from a lower priority user during BSC-controlled inter-cell
incoming handover initiated by a MS. It can reflect the handover
process.
Measurement Intra-BSC target cell receives radio channel request if the
Point request reason is BSC-controlled inter-cell incoming handover
and the target cell has not available radio channel. This counter
increments if receiving handover failure from a lower priority
user after initiating forced handover attempt. The measurement
point is A, as shown in Figure 146.

Confidential and Proprietary Information of ZTE CORPORATION 267


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 146 - RECV FAILURE FROM LOWER PRI USER REQUEST RESOURCE
FOR FORCED HANDOVER (BSC-CONTROLLED INTER-CELL HANDOVER DUE TO
FORCED HANDOVER)

BSC BTS

MEAS_ RESULT
Handover decision success,
unavailable channel, do
forced handover attempt,
send forced handover
request to a lower
priority user, and receive
A failure of handover
CHL_ ACTIV
CHL_ ACTIV_ ACK

Unit Times

C901090165
Definition Number of high PRI user time out for wait resource (BSC-
controlled inter-cell handover due to forced handover)
Description This counter counts the number of timeout for waiting resource
while initiating forced handover due to unavailable radio
resource in target cell in the process of BSC-controlled inter-cell
incoming handover initiated by a MS.
Usage This counter counts the frequency of timeout for waiting
resource while initiating forced handover during BSC-controlled
inter-cell incoming handover initiated by a MS. It can reflect the
handover process.
Measurement Intra-BSC target cell receives radio channel request if the
Point request reason is BSC-controlled inter-cell incoming handover
and the target cell has not available radio channel. This counter
increments if timeout for waiting resource occurs after initiating
forced handover. The measurement point is A, as shown in
Figure 147.

268 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

FIGURE 147 - HIGH PRI USER TIME OUT FOR WAIT RESOURCE (BSC-
CONTROLLED INTER-CELL HANDOVER DUE TO FORCED HANDOVER)

BSC BTS

MEAS_ RESULT

Handover decision success,


unavailable channel, and
timeout for waiting resource
A after forced handover

CHL_ ACTIV
CHL_ ACTIV_ ACK

Unit Times

C901090166
Definition Number of forced release target not found (BSC-controlled inter-
cell handover due to forced release)
Description This counter counts the number of forced release target not
found due to unavailable radio resource in target cell in the
process of BSC-controlled inter-cell incoming handover initiated
by a MS.
Usage This counter counts the frequency of forced release target not
found during BSC-controlled inter-cell incoming handover
initiated by a MS. It can reflect the handover process.
Measurement Intra-BSC target cell receives radio channel request if the
Point request reason is BSC-controlled inter-cell incoming handover
and the target cell has not available radio channel. This counter
increments if the forced release target is not found after
initiating forced release attempt. The measurement point is A, as
shown in Figure 148.

FIGURE 148 - FORCED RELEASE TARGET NOT FOUND (BSC-CONTROLLED


INTER-CELL HANDOVER DUE TO FORCED RELEASE)

BSC BTS

MEAS_ RESULT
Handover decision success,
unavailable channel, do forced
release attempt, and forced
A release target not found
CHL_ ACTIV
CHL_ ACTIV_ ACK

Confidential and Proprietary Information of ZTE CORPORATION 269


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Unit Times

C901090167
Definition Number of high PRI user time out for wait resource (BSC-
controlled inter-cell handover due to forced release)
Description This counter counts the number of timeout for waiting resource
while initiating forced release due to unavailable radio resource
in target cell in the process of BSC-controlled inter-cell incoming
handover initiated by a MS.
Usage This counter counts the frequency of timeout for waiting
resource while initiating forced release during BSC-controlled
inter-cell incoming handover initiated by a MS. It can reflect the
handover process.
Measurement Intra-BSC target cell receives radio channel request if the
Point request reason is BSC-controlled inter-cell incoming handover
and the target cell has not available radio channel. This counter
increments if timeout for waiting resource occurs after initiating
forced release. The measurement point is A, as shown in Figure
149.

FIGURE 149 - HIGH PRI USER TIME OUT FOR WAIT RESOURCE (BSC-
CONTROLLED INTER-CELL HANDOVER DUE TO FORCED RELEASE)

BSC BTS

MEAS_ RESULT

Handover decision success,


unavailable channel, and
timeout for waiting resource
A after foreced release

CHL_ ACTIV
CHL_ ACTIV_ ACK

Unit Times

C901090168
Definition Number of HO Target not found (MSC-controlled incoming
handover due to forced handover)
Description This counter counts the number of HO Target not found (MSC-
controlled incoming handover due to forced handover)
Usage

270 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

This counter counts the frequency of handover target not found


on MSC-controlled incoming handover due to forced handover. It
is one of parameters to measure radio environment.
Measurement 1. This counter increments after BSC receives incoming
Point handover message and does forced handover attempt due to
unavailable resource.
2. This counter increments if the interval timer to search for
handover target is timeout on handover.
3. This counter increments if waiting for handover resource and
handover attempt fails.
4. This counter increments if the timer of waiting for resource is
timeout after initiating forced handover.
Unit Times

C901090169
Definition Number of send forced handover request to lower PRI user
(MSC-controlled incoming handover due to forced handover)
Description This counter counts the number of sending forced handover
request to lower PRI user (MSC-controlled incoming handover
due to forced handover).
Usage This counter counts the frequency of sending handover request
to a lower priority user on MSC-controlled incoming handover
due to forced handover. It is one of parameters to measure
radio environment.
Measurement 1. This counter increments after BSC receives incoming
Point handover message and does forced handover attempt due to
unavailable resource.
2. This counter increments if the interval timer to search for
handover target is timeout on handover.
3. This counter increments if waiting for handover resource and
handover attempt fails.
4. This counter increments if the timer of waiting for resource is
timeout after initiating forced handover.
Unit Times

C901090170
Definition Number of failure to lower PRI user request resource for forced
handover (MSC-controlled incoming handover due to forced
handover)
Description

Confidential and Proprietary Information of ZTE CORPORATION 271


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This counter counts the number of failure to lower PRI user


request resource for forced handover (MSC-controlled incoming
handover due to forced handover).
Usage This counter counts the frequency of failure request resource for
lower priority user on MSC-controlled incoming handover due to
forced handover. It is one of parameters to measure radio
environment.
Measurement This counter increments if BSC receives forced handover failure
Point and incoming handover fails due to failure of resource request.
Unit Times

C901090171
Definition Number of lower PRI user handover failure (MSC-controlled
incoming handover due to forced handover)
Description This counter counts the number of handover failure to lower PRI
user for forced handover (MSC-controlled incoming handover
due to forced handover).
Usage This counter counts the frequency of handover failure for lower
priority user on MSC-controlled incoming handover due to forced
handover. It is one of parameters to measure radio environment.
Measurement This counter increments if BSC receives forced handover failure
Point and incoming handover fails due to failure of forced handover.
Unit Times

C901090172
Definition Number of high PRI user time out for wait resource (MSC-
controlled incoming handover due to forced handover)
Description This counter counts the number of high PRI user time out for
wait resource (MSC-controlled incoming handover due to forced
handover).
Usage This counter counts the frequency of timeout for waiting
resource for higher priority user on MSC-controlled incoming
handover due to forced handover. It is one of parameters to
measure radio environment.
Measurement This counter increments if the timer of waiting for resource after
Point initiating forced handover.
Unit Times

272 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

C901090173
Definition Number of forced release target not found (MSC-controlled
incoming handover due to forced release)
Description This counter counts the number of forced release target not
found (MSC-controlled incoming handover due to forced
handover).
Usage This counter counts the frequency of forced release target not
found on MSC-controlled incoming handover due to forced
handover. It is one of parameters to measure radio environment.
Measurement 1. This counter increments after BSC receives incoming forced
Point release message and does forced release due to unavailable
resource.
2. This counter increments if the interval timer to search for
forced release target is timeout on handover.
3. This counter increments if waiting for handover resource and
forced release fails.
4. This counter increments if the timer of waiting for resource is
timeout after initiating forced handover.
5. This counter increments if the timer to initiate forced release
is timeout on handover.
6. This counter increments if the timer of waiting for resource is
timeout after initiating forced release.
Unit Times

C901090174
Definition Number of high PRI user time out for wait resource (MSC-
controlled incoming handover due to forced release)
Description This counter counts the number of high PRI user time out for
wait resource (MSC-controlled incoming handover due to forced
release).
Usage This counter counts the frequency of timeout for waiting
resource for higher priority user on MSC-controlled incoming
handover due to forced release. It is one of parameters to
measure radio environment.
Measurement This counter increments if the timer of waiting for resource is
Point timeout after initiating forced release.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 273


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901090175
Definition Number of get before grab released channel (assignment forced
handover)
Description This counter counts the number of getting previous grab
released channel (assignment forced handover).
Usage This counter counts the frequency of getting the channel
released by grabbing on forced handover. It is one of
parameters to measure radio environment.
Measurement This counter increments if BSC receives effective messages in
Point resource message on forced handover and the messages hold
database resource.
Unit Times

C901090176
Definition Number of get before grab released channel (assignment forced
release)
Description This counter counts the number of getting previous grab
released channel (assignment forced release).
Usage This counter counts the frequency of getting the channel
released by grabbing on forced release. It is one of parameters
to measure radio environment.
Measurement This counter increments if BSC receives effective messages in
Point resource message on forced release and the messages hold
database resource.
Unit Times

C901090177
Definition Number of handover attempts due to eMLPP forced handover
Description This counter counts the number of handover attempts due to
eMLPP forced handover.
Usage This counter counts the frequency of handover attempts due to
eMLPP forced handover. It is one of parameters to measure
radio environment.
Measurement This counter increments if it is forced handover on intra-cell
Point handover.
This counter increments if it is forced handover based on
hierarchy and frequency relationship on BSC-controlled inter-cell
or MSC-controlled outgoing handover.
Unit Times

274 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - General Handover Measurement

C901090178
Definition Number of handover due to eMLPP forced handover
Description This counter counts the number of handover due to eMLPP
forced handover.
Usage This counter counts the frequency of handover due to eMLPP
forced handover. It is one of parameters to measure radio
environment.
Measurement This counter increments if it is forced handover on intra-cell
Point handover.
This counter increments if it is forced handover based on
hierarchy and frequency relationship on BSC-controlled inter-cell
or MSC-controlled outgoing handover.
Unit Times

C901090179
Definition Number of handover success due to eMLPP forced handover
Description This counter counts the number of handover success due to
eMLPP forced handover.
Usage This counter counts the frequency of handover success due to
eMLPP forced handover. It is one of parameters to measure
radio environment.
Measurement This counter increments if it is intra-cell forced handover on
Point handover success.
This counter increments if it is forced handover based on
hierarchy and frequency relationship on BSC-controlled inter-cell
or MSC-controlled outgoing handover success.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 275


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

276 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11

Adjacent Cell Handover


Measurement

This chapter contains detailed information about counters


related to adjacent cell handover measurement. It records the
number of attempts, failure, and success of MS handover from
one cell to another and the number of handover so as to find out
the handover situation of the cell and its adjacent cell for radio
configuration optimization.

Overview
Adjacent cell handover counter is used to record the number of
outgoing handover or incoming handover so as to find out the
handover between the cell and its adjacent cell which lays a
basis for configuration of adjacent cell and improves service
quality of the cell through handover.
The measurement takes cell as the statistics unit.

Adjacent Cell Handover


Measurement Counter Index
Table 15 lists counters related to adjacent cell handover
measurement.

TABLE 15 - ADJACENT CELL HANDOVER MEASUREMENT COUNTERS

Counter ID What It Counts


Number of handover attempts on the
C901100001
adjacent cell.
Number of handover success from selected
C901100002
cell to the adjacent cell.

Confidential and Proprietary Information of ZTE CORPORATION 277


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter ID What It Counts


Number of handover attempts from
C901100003
adjacent cell to the selected cell.
Number of handover success from
C901100004
adjacent cell to the selected cell.
Number of handover attempts from
C901100005 selected cell to the adjacent cell due to
better UL quality.
Number of handover attempts from
C901100006 selected cell to the adjacent cell due to
better DL quality.
Number of handover success from selected
C901100007 cell to the adjacent cell due to better UL
quality.
Number of handover success from selected
C901100008 cell to the adjacent cell due to better DL
quality.
Number of handover attempts from
C901100009 selected cell to the adjacent cell due to
better UL strength.
Number of handover attempts from
C901100010 selected cell to the adjacent cell due to
better DL strength.
Number of handover success from selected
C901100011 cell to the adjacent cell due to better UL
strength.
Number of handover success from selected
C901100012 cell to the adjacent cell due to better DL
strength.
Number of handover attempts from
C901100013 selected cell to the adjacent cell due to
PBGT

Number of handover success from selected


C901100014
cell to the adjacent cell due to PBGT

Number of handover attempts from


C901100015 selected cell to the adjacent cell due to
other factors.
Number of successful handover from
C901100016 selected cell to the adjacent cell due to
other factors.

Number of pingpong handover (handover


C901100017
to source cell)

C901100001
Definition Number of handover attempts on the adjacent cell.

278 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - Adjacent Cell Handover Measurement

Description This counter counts the number of attempts of handover from


the selected cell to the adjacent cell.
Usage This counter is used to find out the number of attempts of
handover from the selected cell to the adjacent cell so as to
know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point source cell sends radio channel request message to target
cell, the counter increments. The measurement point is A, as
shown in Figure 108.
„ When external handover happens inside one MSC, and
source cell sends handover request message to MSC, the
counter increments. The measurement point is A, as shown
in Figure 109.
Unit Times

C901100002
Definition This counter counts the number of success of handover from the
selected cell to the adjacent cell.
Usage This counter is used to find out the number of success of
handover from the selected cell to the adjacent cell so as to
know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point source cell receives handover completion message from
target cell, the counter increments. The measurement point
is A, as shown in Figure 122.
„ When external handover happens inside one MSC, source cell
receives release command from MSC and the release is due
to handover success, the counter increments. The
measurement point is A, as shown in Figure 127.
Unit Times

C901100003
Definition Number of handover attempts from adjacent cell to the selected
cell.
Usage This counter is used to find out the number of attempts of
handover from adjacent cell to the selected cell so as to know
the handover situation.
Measurement „ When handover happens between cells inside one BSC,
Point target cell receives radio channel request message from
source cell, the counter increments. The measurement point
is A, as shown in Figure 112.

Confidential and Proprietary Information of ZTE CORPORATION 279


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

„ When external handover happens inside one MSC, and target


cell receives handover request message from MSC, the
counter increments. The measurement point is A, as shown
in Figure 119.
Unit Times

C901100004
Definition This counter counts the number of successful handover from the
adjacent cell to the selected cell.
Usage This counter is used to find out the number of success of
handover from the adjacent cell to the selected cell due to better
quality so as to know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point target cell receives handover completion message from MS,
the counter increments. The measurement point is A, as
shown in Figure 121.
„ When external handover happens inside one MSC, and target
cell receives handover completion message from MS, the
counter increments. The measurement point is A, as shown
in Figure 129.
Unit Times

C901100005
Definition Number of handover attempts from selected cell to the adjacent
cell due to better UL quality
Usage This counter is used to find out the number of attempts of
handover from a selected cell to the adjacent cell so as to know
the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point target cell receives radio channel request message from
source cell due to better UL quality, the counter increments.
The measurement point is A, as shown in Figure 112.
„ When external handover happens inside one MSC, target cell
receives handover request message from MSC due to better
UL quality, the counter increments. The measurement point
is A, as shown in Figure 119.
Unit Times

C901100006
Definition

280 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - Adjacent Cell Handover Measurement

Number of handover attempts from selected cell to the adjacent


cell due to better DL quality
Usage This counter is used to find out the number of attempts of
handover from selected cell to the adjacent cell so as to know
the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point target cell receives radio channel request message from
source cell due to better DL quality, the counter increments.
The measurement point is A, as shown in Figure 112.
„ When external handover happens inside one MSC, and target
cell receives handover request message from MSC due to
better DL quality, the counter increments. The measurement
point is A, as shown in Figure 119.
Unit Times

C901100007
Definition Number of successful handover from the selected cell to the
adjacent cell due to better UL quality.
Usage This counter is used to find out the number of successful
handover from a selected cell to the adjacent cell due to better
UL quality so as to know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point source cell receives handover completion message from
target cell due to better UL quality, the counter increments.
The measurement point is A, as shown in Figure 122.
„ When external handover happens inside one MSC, and
source cell receives release command from MSC due to
better UL quality, the counter increments. The measurement
point is A, as shown in Figure 127.
Unit Times

C901100008
Definition Number of handover success from selected cell to the adjacent
cell due to better DL quality
Usage This counter is used to find out the number of successful
handover from a selected cell to the adjacent cell due to better
DL quality so as to know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point source cell receives handover completion message from
target cell due to better DL quality, the counter increments.
The measurement point is A, as shown in Figure 122.

Confidential and Proprietary Information of ZTE CORPORATION 281


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

„ When external handover happens inside one MSC, source cell


receives release command from MSC due to better DL quality,
the counter increments. The measurement point is A, as
shown in Figure 127.
Unit Times

C901100009
Definition Number of handover attempts from selected cell to the adjacent
cell due to better UL strength.
Usage This counter is used to find out the number of attempts of
handover from a selected cell to the adjacent cell due to better
UL strength so as to know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point target cell receives radio channel request message from
source cell due to better UL strength, the counter increments.
The measurement point is A, as shown in Figure 112.
„ When external handover happens inside one MSC, and target
cell receives handover request message from MSC due to
better UL strength, the counter increments. The
measurement point is A, as shown in Figure 119.
Unit Times

C901100010
Definition Number of handover attempts from selected cell to the adjacent
cell due to better DL strength.
Usage This counter is used to find out the number of attempts of
handover from a selected cell to the adjacent cell due to better
DL strength so as to know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point target cell receives radio channel request message from
source cell due to better DL strength, the counter increments.
The measurement point is A, as shown in Figure 112.
„ When external handover happens inside one MSC, and target
cell receives handover request message from MSC due to
better DL strength, the counter increments. The
measurement point is A, as shown in Figure 119.
Unit Times

C901100011
Definition

282 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - Adjacent Cell Handover Measurement

Number of successful handover from selected cell to the


adjacent cell due to better UL strength
Usage This counter is used to find out the number of successful
handover from a selected cell to the adjacent cell due to better
UL strength so as to know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point source cell receives handover completion message from
target cell due to better UL strength, the counter increments.
The measurement point is A, as shown in Figure 122.
„ When external handover happens inside one MSC, and
source cell receives release command from MSC due to
better UL strength, the counter increments. The
measurement point is A, as shown in Figure 127.
Unit Times

C901100012
Definition Number of successful handover from the selected cell to the
adjacent cell due to better DL strength
Usage This counter is used to find out the number of successful
handover from a selected cell to the adjacent cell due to better
DL strength so as to know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point source cell receives handover completion message from
target cell due to better DL strength, the counter increments.
The measurement point is A, as shown in Figure 122.
„ When external handover happens inside one MSC, and
source cell receives release command from MSC due to
better UL strength, the counter increments, as shown in
Figure 127.
Unit Times

C901100013
Definition Number of handover attempts from the selected cell to the
adjacent cell due to better PBGT
Usage This counter is used to find out the number of attempts of
handover from a selected cell to the adjacent cell due to PBGT,
so as to know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point target cell receives radio channel request message from
source cell due to better PBGT, the counter increments. The
measurement point is A, as shown in Figure 112.

Confidential and Proprietary Information of ZTE CORPORATION 283


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

„ When external handover happens inside one MSC, and target


cell receives handover request message from MSC due to
better PBGT, the counter increments. The measurement
point is A, as shown in Figure 119.
Unit Times

C901100014
Definition Number of handover success from selected cell to the adjacent
cell due to better PBGT
Usage This counter is used to find out the number of handover success
from a selected cell to the adjacent cell due to better PBGT, so
as to know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point source cell receives handover completion message from
target cell due to better PBGT, the counter increments. The
measurement point is A, as shown in Figure 122.
„ When external handover happens inside one MSC, and
source cell receives release command from MSC due to
better PBGT, the counter increments. The measurement
point is A, as shown in Figure 127..
Unit Times

C901100015
Definition Number of handover attempts from the selected cell to the
adjacent cell due to other factors.
Usage This counter is used to find out the number of attempts of
handover from a selected cell to the adjacent cell due to other
factors, so as to know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point target cell receives radio channel request message from
source cell due to other factors, the counter increments, as
shown in Figure 112.
„ When external handover happens inside one MSC, and target
cell receives handover request message from MSC due to
other factors, the counter increments, as shown in Figure
119.
Unit Times

C901100016
Definition

284 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - Adjacent Cell Handover Measurement

Number of successful handover from the selected cell to the


adjacent cell due to other factors
Usage This counter is used to find out the number of handover success
from a selected cell to the adjacent cell due to other factors, so
as to know the handover situation.
Measurement „ When handover happens between cells inside one BSC, and
Point source cell receives handover completion message from
target cell due to other factors, the counter increments, as
shown in Figure 122.
„ When external handover happens inside one MSC, and
source cell receives release command from MSC due to other
factors, the counter increments, as shown in Figure 127.
Unit Times

C901100017
Definition Number of pingpong handover (handover to source cell)
Description MS performs handover from cell 1 to cell 2, this counter counts
the number of MS's attempting handover back from cell 2 to cell
1 within specified time.
Usage This counter is used to find out the number of MS's attempting
pingpong handover due to network coverage problems or
inappropriate parameter setting.
Measurement „ For BSC-controlled inter-cell handover, the counter
Point increments when the source cell sends the radio channel
request message to the destination cell. The measurement
point is A, as shown in Figure 108.
„ For MSC-controlled external handover, the counter
increments when the souce cell sends the handover request
message to MSC. The measurement point is A, as shown in
Figure 109.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 285


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

286 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 12

Radio Access
Measurement

Radio access measurement describes MS radio random access


process, including number of access attempt due to various
reasons, number of processing and number of success. This
chapter contains definitions, usages and measurement points of
counters in radio access measurement.

Overview
Radio access counter is mainly used to observe MS radio random
access process as the reference of radio access parameter
adjustment, signaling channel allocation strategy, etc. Several
possible causes of radio access are listed here. Access statistics
related to GPRS is not listed here but in the category of other
access request temporarily.
The number of access request is that of receiving “Channel
Required” message; the number of successful access process is
that of sending “Immediate Assignment” message.
The slot-aloha protocol used in radio access allows many access
requests in one access. We can use the percentage of the
number of successful access process to the number of access
request to describe access success rate. This value represents
signaling channel congestion extent. The percentage of the
number of successful access to the number of access request
represents the collision status in radio access request. If this
value is low, we shall consider factors such as the interval
between access requests, and check whether it is reasonable.
The measurement takes cell as the statistics unit.
Radio access flow and related counters’ locations are shown in
Figure 150.

Confidential and Proprietary Information of ZTE CORPORATION 287


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

FIGURE 150 – RADIO ACCESS PROCESS

MS BTS BSC
CHL_REQ
CHL_RQD

A1

A2
CHL_ACT

CHL_ACT_ACK

A3

IMM_ASS_ CMD
IMM_ASS
SABM
EST_IND

A4

Radio Access Measurement Counter


Index
Table 16 lists counters related to radio access measurement.

TABLE 16 - RADIO ACCESS MEASUREMENT COUNTERS

Counter What It Counts


C901110001 Number of invalid access requests
Number of MOC access success for
C901110003
processes
Number of MTC access success for
C901110006
processes
Number of call re-establishment access
C901110008
attempts
Number of call re-establishment access
C901110009
success for processes
Number of call re-establishment access
C901110010
success
Number of emergency calls access
C901110011
attempts
Number of emergency calls access success
C901110012
for processes
C901110013 Number of emergency calls access success
C901110014 Number of LOC access attempts
Number of LOC access success for
C901110015
processes
C901110016 Number of LOC access success

288 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 12 - Radio Access Measurement

Counter What It Counts


C901110017 Number of other causes access attempts
Number of successful random access
C901110018
processes for other causes
C901110019 Number of other causes access success
Number of LMU Establishment Access
C901110020
attempts
Number of LMU Establishment access
C901110021
success for processes
Number of LMU Establishment access
C901110022
success
C901110023 Number of accesses due to location update
C901110024 Number of Access due to CM SERVICE REQ
Number of CM service requests of
C901110026
Emergency Call
C901110027 Number of CM service requests of SMS
Number of CM service requests of
C901110028
Supplement
C901110029 Number of CM service requests of LCS
Number of wireless access due to call re-
C901110031
establishments
Number of wireless accesses due to IMSI
C901110032
detachment
Number of wireless accesses due to other
C901110033
causes

C901110001
Definition Number of invalid access requests
Description This counter counts the number of invalid access requests. The
counter increments when MS sends “CHL_REQ” message
through BTS to BSC for requiring radio channel and TA exceeds
cell scope, and then BSC regards the access request as
interference and abandons the request.
Usage This counter is used to find out the frequency of invalid access
request.
Measurement The counter increments when MS fails in requiring radio channel
Point from BSC because TA exceeds cell scope. The measurement
point is A2, as shown in Figure 150.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 289


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901110003
Definition Number of MOC access success for processes
Description This counter counts the Number of MOC access success for
processes. The counter increments when BSC allows MS to be
accessed into the network due to MOC attempts and accepts
channel request sent by MS and allocates and activates channel
successfully. Meanwhile, BSC sends message IMM_ASS to MS.
Usage This counter is used to find out the frequency of successful
random access processes due to MOC attempts.
Measurement The counter increments when channel is activated successfully.
Point The measurement point is A3, as shown in Figure 150.
Unit Times

C901110006
Definition Number of MTC access success for processes
Description This counter counts the Number of MTC access success for
processes. The counter increments when BSC allows MS to be
accessed into the network due to MTC attempts and accepts
channel request sent by MS and allocates and activates channel
successfully. Meanwhile, BSC sends “IMM_ASS” message to MS.
Usage This counter is used to find out the frequency of successful
random access processes due to MTC attempts.
Measurement The counter increments when channel is activated successfully.
Point The measurement point is A3, as shown in Figure 150.
Unit Times

C901110008
Definition Number of call re-establishment access attempts
Description This counter counts the Number of call re-establishment access
attempts. The counter increments when MS sends “CHL_REQ”
message through BTS to BSC for requiring radio channel, if TA
does not exceed cell scope and the access cause is call re-
establishment.
Usage This counter is used to find out the frequency of random access
attempts due to call re-establishment.
Measurement The counter increments when MS requires channel from BSC and
Point TA does not exceed the scope. The measurement point is A1, as
shown in Figure 150.
Unit Times

290 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 12 - Radio Access Measurement

C901110009
Definition Number of call re-establishment access success for processes
Description This counter counts the Number of call re-establishment access
success for processes. The counter increments when BSC allows
MS to be accessed into the network due to call re-establishment
and accepts channel request sent by MS and allocates and
activates channel successfully. Meanwhile, BSC sends
‘IMM_ASS´ message to MS.
Usage This counter is used to find out the frequency of random access
processes due to call re-establishment.
Measurement The counter increments when channel is activated successfully.
Point The measurement point is A3, as shown in Figure 150.
Unit Times

C901110010
Definition Number of call re-establishment access success.
Description This counter counts the Number of call re-establishment access
success. The counter increments when MS receives “IMM_ASS”
message sent by BSC and successfully accesses corresponding
channel and BSC receives “EST_IND” message sent by MS.
Usage This counter is used to find out the frequency of successful
access of call re-establishment.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

C901110011
Definition Number of emergency calls access attempts
Description This counter counts the Number of emergency calls access
attempts. The counter increments when MS sends “CHL_REQ”
message through BTS to BSC for requiring radio channel, if TA
does not exceed cell scope and the access cause is emergency
calls.
Usage This counter is used to find out the frequency of random access
attempts due to emergency calls.
Measurement The counter increments when MS requires channel from BSC and
Point TA does not exceed the scope. The measurement point is A1, as
shown in Figure 150.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 291


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901110012
Definition Number of emergency calls access success for processes
Description This counter counts the Number of emergency calls access
success for processes. The counter increments when BSC allows
MS to be accessed into the network due to emergency calls and
accepts channel request sent by MS and allocates and activates
channel successfully. Meanwhile, BSC sends “IMM_ASS”
message to MS.
Usage This counter is used to find out the frequency of random access
processes due to emergency calls.
Measurement The counter increments when channel is activated successfully.
Point The measurement point is A3, as shown in Figure 150.
Unit Times

C901110013
Definition Number of emergency calls access success
Description This counter counts the Number of emergency calls access
success. The counter increments when MS receives “IMM_ASS”
message sent by BSC and successfully accesses corresponding
channel and BSC receives “EST_IND” message sent by MS.
Usage This counter is used to find out the frequency of successful
access of emergency calls.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

C901110014
Definition Number of LOC access attempts
Description This counter counts the Number of LOC access attempts. The
counter increments when MS sends “CHL_REQ” message
through BTS to BSC for requiring radio channel, if TA does not
exceed cell scope and the access cause is LOC.
Usage This counter is used to find out the frequency of random access
attempts due to LOC.
Measurement The counter increments when MS requires channel from BSC and
Point TA does not exceed the scope. The measurement point is A1, as
shown in Figure 150.
Unit Times

292 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 12 - Radio Access Measurement

C901110015
Definition Number of LOC access success for processes
Description This counter counts the number of successful random access
processes due to LOC. The counter increments when BSC allows
MS to be accessed into the network due to emergency calls and
accepts channel request sent by MS and allocates and activates
channel successfully. Meanwhile, BSC sends “IMM_ASS”
message to MS.
Usage This counter is used to find out the frequency of random access
processes due to LOC.
Measurement The counter increments when channel is activated successfully.
Point The measurement point is A3, as shown in Figure 150.
Unit Times

C901110016
Definition Number of LOC access success
Description This counter counts the number of access success. The counter
increments when MS receives “IMM_ASS” message sent by BSC
and successfully accesses corresponding channel and BSC
receives “EST_IND” message sent by MS.
Usage This counter is used to find out the frequency of LOC access
success.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

C901110017
Definition Number of other causes access attempts
Description This counter counts the Number of other causes access attempts
(except MOC, MTC, call re-establishment, LOC and emergency
calls). The counter increments when MS sends “CHL_REQ”
message through BTS to BSC for requiring radio channel, if TA
does not exceed cell scope and the access cause is other causes.
Usage This counter is used to find out the frequency of random access
attempts due to other causes.
Measurement The counter increments when MS requires channel from BSC and
Point TA does not exceed the scope. The measurement point is A1, as
shown in Figure 150.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 293


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901110018
Definition Number of successful random access processes for other causes
Description This counter counts the number of successful random access
processes for other causes. The counter increments when BSC
allows MS to be accessed into the network due to other causes
and accepts channel request sent by MS and allocates and
activates channel successfully. Meanwhile, BSC sends
“IMM_ASS” message to MS.
Usage This counter is used to find out the frequency of random access
processes due to other causes.
Measurement The counter increments when channel is activated successfully.
Point The measurement point is A3, as shown in Figure 150.
Unit Times

C901110019
Definition Number of other causes access success
Description This counter counts the Number of other causes access success.
The counter increments when MS receives “IMM_ASS” message
sent by BSC and successfully accesses corresponding channel
and BSC receives “EST_IND” message sent by MS.
Usage This counter is used to find out the frequency of other successful
access requests.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

C901110020
Definition Number of LMU Establishment Access attempts
Description This counter counts the Number of LMU Establishment Access
attempts. The counter increments when MS sends “CHL_REQ”
message through BTS to BSC for requiring radio channel, if TA
does not exceed cell scope and the access cause is LMU
establishment.
Usage This counter is used to find out the frequency of LMU
establishment access request.
Measurement The counter increments when MS requires channel from BSC and
Point TA does not exceed the scope. The measurement point is A1, as
shown in Figure 150.
Unit Times

294 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 12 - Radio Access Measurement

C901110021
Definition Number of LMU Establishment access success for processes
Description This counter counts the Number of LMU Establishment access
success for processes. The counter increments when MS sends
“CHL_REQ” message through BTS to BSC for requiring radio
channel, if TA does not exceed cell scope and the access cause is
LMU establishment.
Usage This counter is used to find out the frequency of LMU
establishment access request successfully.
Measurement The counter increments when channel is activated successfully.
Point The measurement point is A3, as shown in Figure 150.
Unit Times

C901110022
Definition Number of LMU Establishment access success
Description This counter counts the Number of LMU Establishment access
success. The counter increments when MS sends “CHL_REQ”
message through BTS to BSC for requiring radio channel, if TA
does not exceed cell scope and the access cause is LMU
establishment.
Usage This counter is used to find out the frequency of LMU
establishment access successfully.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

C901110023
Definition Number of wireless accesses due to location update
Description This counter counts the Number of wireless accesses due to
location update. The counter increments when the access cause
in Layer3 information carried in “EST_IND” message received by
BSC is location update.
Usage This counter is used to find out the frequency of radio channel
accesses due to location update.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 295


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901110024
Definition Number of Access due to CM SERVICE REQ
Description This counter counts the Number of Access due to CM SERVICE
REQ. The counter increments when the access cause in Layer3
information carried in “EST_IND” message received by BSC is
CM SERVICE REQ.
Usage This counter is used to find out the frequency of access caused
by CM SERVICE REQ.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

C901110026
Definition Number of access of CM SERVICE REQ's emergency call
Description This counter counts the number of access of CM SERVICE REQ's
emergency call. The counter increments when it is emergency
call and the access cause in Layer3 information carried in
“EST_IND” message received by BSC is CM SERVICE REQ.
Usage This counter is used to find out the frequency of access of CM
SERVICE REQ's emergency call.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

C901110027
Definition Number of access of SMS's CM SERVICE REQ
Description This counter counts the number of access of SMS's CM SERVICE
REQ. The counter increments when it is SMS access among
other accesses and the access cause in Layer3 information
carried in “EST_IND” message received by BSC is CM SERVICE
REQ.
Usage This counter is used to find out the frequency of access of SMS's
CM SERVICE REQ.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

296 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 12 - Radio Access Measurement

C901110028
Definition Number of access of supplement's CM SERVICE REQ
Description This counter counts the number of access of supplement's CM
SERVICE REQ. The counter increments when it is supplement
access among other accesses and the access cause in Layer3
information carried in “EST_IND” message received by BSC is
CM SERVICE REQ.
Usage This counter is used to find out the frequency of access of
supplement's CM SERVICE REQ.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

C901110029
Definition Number of access of LCS's CM SERVICE REQ
Description This counter counts the number of access of supplement's CM
SERVICE REQ. The counter increments when it is LCS access
among other accesses and the access cause in Layer3
information carried in “EST_IND” message received by BSC is
CM SERVICE REQ.
Usage This counter is used to find out the frequency of access of LCS's
CM SERVICE REQ.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

C901110031
Definition Number of wireless accesses due to call re-establishments
Description This counter counts the Number of wireless accesses due to call
re-establishments. The counter increments when the access
cause in Layer3 information carried in “EST_IND” message
received by BSC is call re-establishments.
Usage This counter is used to find out the frequency of radio channel
accesses due to call re-establishments.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 297


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901110032
Definition Number of wireless accesses due to IMSI detachment
Description This counter counts the Number of wireless accesses due to IMSI
detachment. The counter increments when the access cause in
Layer3 information carried in “EST_IND” message received by
BSC is IMSI detachment.
Usage This counter is used to find out the frequency of radio channel
accesses due to IMSI detachment.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

C901110033
Definition Number of wireless accesses due to other causes
Description This counter counts the Number of wireless accesses due to
other causes (except location update, call establishment, paging
response, call re-establishment and IMSI detachment). The
counter increments when the access cause in Layer3 information
carried in “EST_IND: message received by BSC is other causes.
Usage This counter is used to find out the frequency of radio channel
accesses due to other causes.
Measurement The counter increments when BSC receives “EST_IND” message.
Point The measurement point is A4, as shown in Figure 150.
Unit Times

298 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13

Radio Measurement

Cell radio measurement describes the status of interference and


service quality of occupied and idle cell channels. This chapter
contains definitions, usages and measurement points of counters
in cell radio measurement.

Overview
Cell radio measurement items mainly include UL/DL quality,
signal strength, TA, interference band and RQ value of radio
channels. The UL/DL quality, signal strength, TA and RQ value
are counted after measurement report or pre-processing
measurement report sent by BTS is received; BSC updates
interference band status in database after receiving
measurement report or pre-processing measurement report. The
value of interference band can be inquired in database when
periodical measurement is reported.
The measurement takes cell as the statistics unit.

Radio Measurement Counter Index


Table 17 lists counters related to radio measurement.

TABLE 17 - RADIO MEASUREMENT COUNTERS

Counter What It Counts


Number of UL signal quality samples in
C901120001
wireless channels
Level of worst UL signal quality in wireless
C901120002
channels
Total value of UL quality level values in
C901120003
wireless channels
Number of DL signal quality samples in
C901120004
wireless channels

Confidential and Proprietary Information of ZTE CORPORATION 299


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Counter What It Counts


Level of worst DL signal quality in wireless
C901120005
channels
Total value of DL quality strength values in
C901120006
wireless channels
Number of received UL signal strength
C901120007
samples in wireless channels
Maximum received UL signal strength in
C901120008
wireless channels
Minimum received UL signal strength in
C901120009
wireless channels
Total value of UL signal strength in
C901120010
wireless channels
Number of received DL signal strength
C901120011
samples in wireless channels
Maximum received DL signal strength in
C901120012
wireless channels
Minimum DL received signal strength in
C901120013
wireless channels
Total value of DL signal strength in
C901120014
wireless channels
Number of TA samples in wireless
C901120015
channels
C901120016 Maximum TA in wireless channels
C901120017 Total number of TAs in wireless channels
Mean number of idle TCH/Fs with
C901120018
interference band 0
Mean number of idle TCH/Hs with
C901120024
interference band 0
Mean number of idle SDCCHs with
C901120030
interference band 0
Mean number of idle SDCCHs with
C901120031
interference band 1
Mean number of idle SDCCHs with
C901120032
interference band 2
Mean number of idle SDCCHs with
C901120033
interference band 3
Mean number of idle SDCCHs with
C901120034
interference band 4
Mean number of idle SDCCHs with
C901120035
interference band 5
C901120052 Number of TFO initiations
C901120053 Number of using noise suppression
Number of mode changes for establishing
C901120054
TFO

300 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13 - Radio Measurement

Counter What It Counts


Number of mode changes for optimizing
C901120055
TFO
Number of active collection changes for
C901120056
establishing TFO
Number of active collection changes for
C901120057
optimizing TFO
Number of samples with voice quality is
C901120058
excellent
Number of samples with voice quality is
C901120059
good
Number of samples with voice quality is
C901120060
medium
Number of samples with voice quality is
C901120061
bad
Number of samples with voice quality is
C901120062
awfully

C901120001
Definition Number of UL signal quality samples in radio channels
Description This counter counts the number of received UL radio
measurement report or pre-processing measurement report. The
counter increments when BSC receives UL radio measurement
report or pre-processing measurement report.
Usage This counter is used to find out the frequency of UL signal
quality samples in radio channels.
Measurement The counter increments when BSC receives UL measurement
Point report or pre-processing measurement report.
Unit Times

C901120002
Definition Level of worst UL signal quality in radio channels
Description This counter counts the number of radio channels with the worst
UL signal quality in UL measurement report or pre-processing
measurement report. If the level of UL signal quality in radio
channel in UL measurement report or pre-processing
measurement report received by BSC is worse than the recorded
worst level of UL signal quality, then the new worst level of UL
signal quality will be recorded.
Usage This counter is used to find out status of the level of the worst
UL signal quality in radio channels.

Confidential and Proprietary Information of ZTE CORPORATION 301


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Measurement The counter counts when BSC receives UL measurement report


Point or pre-processing measurement report.
Unit None

C901120003
Definition Total value of UL quality level values in radio channels
Description This counter counts the number of total value of UL quality level
values in radio channels in radio measurement reports. The
counter accumulates UL quality level values in radio channels in
UL measurement report or pre-processing measurement report
received by BSC.
Usage This counter is used to find out status of total value of UL quality
level values in radio channels.
Measurement The counter counts when BSC receives UL measurement report
Point or pre-processing measurement report.
Unit None

C901120004
Definition Number of DL signal quality samples in radio channels
Description This counter counts the number of received DL radio
measurement report or pre-processing measurement report. The
counter increments when BSC receives DL radio measurement
report or pre-processing measurement report.
Usage This counter is used to find out the frequency of DL signal
quality samples in radio channels.
Measurement The counter increments when BSC receives DL measurement
Point report or pre-processing measurement report.
Unit Times

C901120005
Definition Level of worst DL signal quality in radio channels
Description This counter counts the number of radio channels with the worst
DL signal quality in DL measurement report or pre-processing
measurement report. If the level of DL signal quality in radio
channel in DL measurement report or pre-processing
measurement report received by BSC is worse than the recorded
worst level of DL signal quality, then the new worst level of DL
signal quality will be recorded.

302 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13 - Radio Measurement

Usage This counter is used to find out status of the level of the worst
DL signal quality in radio channels.
Measurement The counter counts when BSC receives DL measurement report
Point or pre-processing measurement report.
Unit None

C901120006
Definition Total value of DL quality level values in radio channels
Description This counter counts the number of total value of DL quality level
values in radio channels in radio measurement reports. The
counter accumulates DL quality level values in radio channels in
DL measurement report or pre-processing measurement report
received by BSC.
Usage This counter is used to find out status of total value of DL quality
level values in radio channels.
Measurement The counter counts when BSC receives DL measurement report
Point or pre-processing measurement report.
Unit None

C901120007
Definition Number of received UL signal strength samples in radio channels
Description This counter counts the number of received UL signal strength
samples in radio channels in UL measurement report. The
counter increments when BSC receives UL measurement report
or pre-processing measurement report.
Usage This counter is used to find out frequency of received UL signal
strength samples in radio channels.
Measurement The counter increments when BSC receives UL measurement
Point report or pre-processing measurement report.
Unit Times

C901120008
Definition Maximum received UL signal strength in radio channels
Description This counter counts the maximum received UL signal strength in
radio channels in UL measurement report. If the UL signal
strength in radio channel in UL measurement report or pre-
processing measurement report received by BSC is higher than
the recorded highest UL signal strength, then the new highest
UL signal strength will be recorded.

Confidential and Proprietary Information of ZTE CORPORATION 303


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Usage This counter is used to find out status of maximum received UL


signal strength in radio channels.
Measurement The counter counts when BSC receives UL measurement report
Point or pre-processing measurement report.
Unit None

C901120009
Definition Minimum received UL signal strength in radio channels
Description This counter counts the minimum received UL signal strength in
radio channels in UL measurement report. If the UL signal
strength in radio channel in UL measurement report or pre-
processing measurement report received by BSC is lower than
the recorded lowest UL signal strength, then the new lowest UL
signal strength will be recorded.
Usage This counter is used to find out status of minimum received UL
signal strength in radio channels.
Measurement The counter counts when BSC receives UL measurement report
Point or pre-processing measurement report.
Unit None

C901120010
Definition Total value of UL signal strength in radio channels
Description This counter counts the number of total value of UL signal
strength in radio channels in radio measurement reports. The
counter accumulates values of UL signal strength in radio
channels in UL measurement report or pre-processing
measurement report received by BSC.
Usage This counter is used to find out status of total value of UL signal
strength in radio channels.
Measurement The counter counts when BSC receives UL measurement report
Point or pre-processing measurement report.
Unit None

C901120011
Definition Number of received DL signal strength samples in radio channels
Description This counter counts the number of received DL signal strength
samples in radio channels in DL measurement report. The
counter increments when BSC receives DL measurement report
or pre-processing measurement report.

304 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13 - Radio Measurement

Usage This counter is used to find out frequency of received DL signal


strength samples in radio channels.
Measurement The counter increments when BSC receives DL measurement
Point report or pre-processing measurement report.
Unit Times

C901120012
Definition Maximum received DL signal strength in radio channels
Description This counter counts the maximum received DL signal strength in
radio channels in DL measurement report. If the DL signal
strength in radio channel in DL measurement report or pre-
processing measurement report received by BSC is higher than
the recorded highest DL signal strength, then the new highest
DL signal strength will be recorded.
Usage This counter is used to find out status of maximum received DL
signal strength in radio channels.
Measurement The counter counts when BSC receives DL measurement report
Point or pre-processing measurement report.
Unit None

C901120013
Definition Minimum received DL signal strength in radio channels
Description This counter counts the minimum received DL signal strength in
radio channels in DL measurement report. If the DL signal
strength in radio channel in DL measurement report or pre-
processing measurement report received by BSC is lower than
the recorded lowest DL signal strength, then the new lowest DL
signal strength will be recorded.
Usage This counter is used to find out status of minimum received DL
signal strength in radio channels.
Measurement The counter counts when BSC receives DL measurement report
Point or pre-processing measurement report.
Unit None

C901120014
Definition Total value of DL signal strength in radio channels
Description This counter counts the number of total value of DL signal
strength in radio channels in radio measurement reports. The
counter accumulates values of DL signal strength in radio

Confidential and Proprietary Information of ZTE CORPORATION 305


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

channels in DL measurement report or pre-processing


measurement report received by BSC.
Usage This counter is used to find out status of total value of DL signal
strength in radio channels.
Measurement The counter counts when BSC receives DL measurement report
Point or pre-processing measurement report.
Unit None

C901120015
Definition Number of TA samples in radio channels
Description This counter counts the number of TA samples in radio channels
in radio measurement reports. The counter increments when
BSC receives measurement report or pre-processing
measurement report.
Usage This counter is used to find out frequency of TA samples in radio
channels.
Measurement The counter increments when BSC receives measurement report
Point or pre-processing measurement report.
Unit Times

C901120016
Definition Maximum TA in radio channels
Description This counter counts the maximum TA in radio measurement
reports. If the value of TA in radio channels in measurement
report or pre-processing measurement report received by BSC is
larger than the recorded highest value of TA, then the new
largest value of TA will be recorded.
Usage This counter is used to find out status of maximum TA in radio
channels.
Measurement The counter counts when BSC receives measurement report or
Point pre-processing measurement report.
Unit Second

C901120017
Definition Total number of TAs in radio channels
Description This counter counts the number of TAs in radio channels in radio
measurement reports. The counter accumulates values of TA in
radio channels in measurement report or pre-processing
measurement report received by BSC.

306 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13 - Radio Measurement

Usage This counter is used to find out status of total value of TA in


radio channels.
Measurement The counter counts when BSC receives measurement report or
Point pre-processing measurement report.
Unit Second

C901120018
Definition Mean number of idle TCH/Fs with interference band 0
Description This counter counts the mean number of idle TCH/Fs with
interference band 0.
Usage This counter is used to find out number of idle TCH/Fs with
interference band 0.
Measurement The counter increments when timed database inquiry is carried
Point out.
Unit Times

C901120024
Definition Mean number of idle TCH/Hs with interference band 0.
Description This counter counts the mean number of idle TCH/Hs with
interference band 0.
Usage This counter is used to find out number of idle TCH/Hs with
interference band 0.
Measurement The counter increments when timed database inquiry is carried
Point out.
Unit Times

C901120030
Definition Mean number of idle SDCCHs with interference band 0
Description This counter counts the mean number of idle SDCCHs with
interference band 0.
Usage This counter is used to find out number of idle SDCCHs with
interference band 0.
Measurement The counter increments when timed database inquiry is carried
Point out.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 307


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901120031
Definition Mean number of idle SDCCHs with interference band 1
Description This counter counts the mean number of idle SDCCHs with
interference band 1.
Usage This counter is used to find out number of idle SDCCHs with
interference band 1.
Measurement The counter increments when timed database inquiry is carried
Point out.
Unit Times

C901120032
Definition Mean number of idle SDCCHs with interference band 2
Description This counter counts the mean number of idle SDCCHs with
interference band 2.
Usage This counter is used to find out number of idle SDCCHs with
interference band 2.
Measurement The counter increments when timed database inquiry is carried
Point out.
Unit Times

C901120033
Definition Mean number of idle SDCCHs with interference band 3
Description This counter counts the mean number of idle SDCCHs with
interference band 3.
Usage This counter is used to find out number of idle SDCCHs with
interference band 3.
Measurement The counter increments when timed database inquiry is carried
Point out.
Unit Times

C901120034
Definition Mean number of idle SDCCHs with interference band 4.
Description This counter counts the mean number of idle SDCCHs with
interference band 4.

308 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13 - Radio Measurement

Usage This counter is used to find out number of idle SDCCHs with
interference band 4.
Measurement The counter increments when timed database inquiry is carried
Point out.
Unit Times

C901120035
Definition Mean number of idle SDCCHs with interference band 5
Description This counter counts the mean number of idle SDCCHs with
interference band 5.
Usage This counter is used to find out number of idle SDCCHs with
interference band 5.
Measurement The counter increments when timed database inquiry is carried
Point out.
Unit Times

C901120052
Definition Number of TFO initiations
Description This counter counts the number of TFOs established by BSC.
Measurement When the RANCS service process of BSC receives TFO status
Point message and TFO has been established, the counter increments.
Unit Times

C901120053
Definition Number of using noise suppression
Description This counter does not count for the time being.

C901120054
Definition Number of mode changes for establishing TFO
Description This counter does not count for the time being.

C901120055
Definition Number of mode changes for optimizing TFO

Confidential and Proprietary Information of ZTE CORPORATION 309


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Description This counter does not count for the time being.

C901120056
Definition Number of active collection changes for establishing TFO
Description This counter does not count for the time being.

C901120057
Definition Number of active collection changes for optimizing TFO
Description This counter does not count for the time being.

C901120058
Definition Number of samples with voice quality is excellent
Description This counter counts the number of voice quality being excellent.
When the UL measurement report, preprocessing measurement
report, or enhanced preprocessing measurement report is
received, if the voice quality is excellent, the counter increments.
Usage This counter is used to find out the UL voice quality on the radio
channel.
Measurement When BSC receives the UL measurement report, preprocessing
Point measurement report, or enhanced preprocessing measurement
report, if the voice quality is excellent, the counter increments.
Unit Times

C901120059
Definition Number of samples with voice quality is good
Description This counter counts the number of voice quality being good.
When the UL measurement report, preprocessing measurement
report, or enhanced preprocessing measurement report is
received, if the voice quality is good, the counter increments.
Usage This counter is used to find out the UL voice quality on the radio
channel.
Measurement When BSC receives the UL measurement report, preprocessing
Point measurement report, or enhanced preprocessing measurement
report, if the voice quality is good, the counter increments.
Unit Times

310 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13 - Radio Measurement

C901120060
Definition Number of samples with voice quality is medium
Description This counter counts the number of voice quality being medium.
When the UL measurement report, preprocessing measurement
report, or enhanced preprocessing measurement report is
received, if the voice quality is medium, the counter increments.
Usage This counter is used to find out the UL voice quality on the radio
channel.
Measurement When BSC receives the UL measurement report, preprocessing
Point measurement report, or enhanced preprocessing measurement
report, if the voice quality is medium, the counter increments.
Unit Times

C901120061
Definition Number of samples with voice quality is bad
Description This counter counts the number of voice quality being bad.
When the UL measurement report, preprocessing measurement
report, or enhanced preprocessing measurement report is
received, if the voice quality is bad, the counter increments.
Usage This counter is used to find out the UL voice quality on the radio
channel.
Measurement When BSC receives the UL measurement report, preprocessing
Point measurement report, or enhanced preprocessing measurement
report, if the voice quality is bad, the counter increments.
Unit Times

C901120062
Definition Number of samples with voice quality is awfully
Description This counter counts the number of voice quality being awful.
When the UL measurement report, preprocessing measurement
report, or enhanced preprocessing measurement report is
received, if the voice quality is awful, the counter increments.
Usage This counter is used to find out the UL voice quality on the radio
channel.
Measurement When BSC receives the UL measurement report, preprocessing
Point measurement report, or enhanced preprocessing measurement
report, if the voice quality is awful, the counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 311


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

312 Confidential and Proprietary Information of ZTE CORPORATION


Appendix A

Abbreviations

Abbreviation Full Name


A
Abis Abis Interface
AIPP A-Interface Peripheral Processor
AIU A-Interface Unit
AUC Access Unit Controller
B
BCCH Broadcast Channel
BSC Base Station Controller
BTS Base Transceiver Station
BSSAP Base Station Subsystem Application Part
BSSGP Base Station Subsystem GPRS Protocol
BSSMAP Base Station Subsystem Management
Application Part
BTS Base Transceiver Station
BVC BSSGP Virtual Connection
BVCI BSSGP Virtual Connection Identifier
C
CBCH Cell Broadcast Channel
CC Call Control
CCCH Common Control Channel
CCH Control Channel
CS Circuit Switched
D
DL Downlink
DRT Dual Rate Transcoder
DTAP Direct Transfer Application Part

Confidential and Proprietary Information of ZTE CORPORATION 313


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Abbreviation Full Name


E
EDRT Enhanced Dual Rate Transcoder
EGSM Extended GSM
F
FACCH Fast Associated Control Channel
FACCH/F Fast Associated Control Channel/Full rate
FACCH/H Fast Associated Control Channel/Half rate
FR Frame Relay
FRP Frame Relay Protocol
FU Frame Unit
G
GGSN Gateway GPRS Support Node
GIU GPRS Interface Unit
GPRS General Packet Radio Service
GSM Global System for Mobile communication
GSN GPRS Support Node
H
HSN Hopping Sequence Number
K
KPI Key Performance Indicator
L
LAPD Link Access Protocol of D-Channel
LLC Logical Link Control
LMT Local Management Terminal
LOC Location update
M
MM Mobility Management
MOC Mobile Originated Call
MS Mobile Station
MSC Mobile Switching Center
MO-SM MS Originated Short Message
MT-SM MS Terminated Short Message
MTC Mobile Terminated Call
MTP Message Transfer Part
N
NC Network Controller
NMS Network Management Signaling

314 Confidential and Proprietary Information of ZTE CORPORATION


Appendix A - Abbreviations

Abbreviation Full Name


NMS Network Management Software
NS Network Service
NSE Network Service Entity
NSEI Network Service Entity Identifier
NSVC Network Service Virtual Circuit
O
OMC Operation Maintenance Center
OMCR Operation Maintenance Center Radio
P
PACCH Packet Associated Control Channel
PAGCH Paging and Access Grant Channel
PBGT Power Budget
PCH Paging Channel
PCU Packet Control Unit
PDU Protocol Data Unit
PDCH Packet Data Channel
PDTCH Packet Data Traffic Channel
PDU Protocol Data Unit
PS Packet Switched
R
RMM Radio Management Module
RQ Receiving Quality
RR Radio Resource
S
SACCH Slow Associated Control Channel
SACCH/F Slow Associated Control Channel/Full rate
SACCH/H Slow Associated Control Channel/Half rate
SAPI Service Access Point Identifier
SCCP Signal Correction Control Part
SDCCH Slow Distributed Control Channel
SGSN Serving GPRS Support Node
SIF Service Information Field
SIO Service Information Octets
SM Short Message
SMM Service Management Module
SMS Short Messages Service
SS Supplementary Services

Confidential and Proprietary Information of ZTE CORPORATION 315


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Abbreviation Full Name


T
TA Time Advance
TCH Traffic Channel
TCH/F Traffic Channel/Full rate
TCH/H Traffic Channel/Half rate
TFO Tandem Free Operation
TIC Trunk Interface Circuit
TRX Transceiver
U
UISF User Interface Support Foundation
UL Uplink

316 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B

Figures

Figure 1 - Measurement Point of Number of Resumption for


GPRS DL TBF in Delay State............................................... 11
Figure 2 – Number of Request Failures for Establishing GPRS on
PACCH (No Response from Control Plane) ............................ 12
Figure 3 – Failures for Establishing DL GPRS TBF on
CCCH/PCCCH (1).............................................................. 13
Figure 4 – Failures for Establishing DL GPRS TBF on
CCCH/PCCCH (2).............................................................. 13
Figure 5 – Normal Establishment of DL GPRS TBF on
CCCH/PCCCH ................................................................... 14
Figure 6 – LLC Frame Transmits GTTP Message in DTM Mode .. 15
Figure 7 – DTM Assignment in DTM Mode............................. 15
Figure 8 – Measurement Point of Number of Times for
Establishing GPRS DL TBF with Polling Failed on CCCH/PCCCH. 16
Figure 9 – Normal Release of DL TBF................................... 18
Figure 10 – Measurement of Cumulated Overall DL Connecting
Time............................................................................... 23
Figure 11 – Measurement Point on Receiving New Data Block in
GPRS Extended UL State ................................................... 29
Figure 12 – Measurement Point on Receiving Resource
Reassignment for GPRS UL TBF in Delayed UL State .............. 29
Figure 13 – Measurement Point on Number of Request Failures
Caused by Timeout for Establishing GPRS on PACCH GPRS ..... 30
Figure 14 – Measurement Point on Number of establishment
failures of GPRS UL TBF caused by competition solution failure 31
Figure 15 – Measurement Point on Number of establishment
failures of GPRS UL TBF caused by Not Receiving Resource
Request .......................................................................... 32
Figure 16 – Measurement Point on Number of Successful GPRS
UL TBF Establishment on CCCH/PCCCH (I) ........................... 33
Figure 17 – Measurement Point on Number of Successful GPRS

Confidential and Proprietary Information of ZTE CORPORATION 317


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

UL TBF Establishment on CCCH/PCCCH (II) .......................... 34


Figure 18 – Measurement Point on Number of Normal GPRS UL
TBF Release..................................................................... 34
Figure 19 – Measurement Point on Number of Resumptions for
EGPRS UL TBF in Extended UL State ................................... 35
Figure 20 – Measurement Point on Number of Resource
Reassignments for EGPRS UL TBF in Delayed UL State ........... 35
Figure 21 – Measurement Point on Number of Request Failures
Caused by Timeout for Establishing EGPRS on on PACCH........ 36
Figure 22 – Measurement Point on Number of establishment
failures of EGPRS UL TBF caused by competition solving failed 37
Figure 23 – Measurement Point on Number of establishment
failures of EGPRS UL TBF caused by Not Receiving Resource
Request .......................................................................... 38
Figure 24 – Measurement Point on Number of Successful EGPRS
UL TBF Establishment on CCCH/PCCCH (I) ........................... 39
Figure 25 – Measurement Point on Number of Successful EGPRS
UL TBF Establishment on CCCH/PCCCH (II) .......................... 39
Figure 26 – Measurement Point on Number of Normal EGPRS UL
TBF Release..................................................................... 40
Figure 27 – Measurement Point on Number of Normal GPRS
Signaling UL TBF Release................................................... 42
Figure 28 – Measurement Point on Number of Normal GPRS
Signaling UL TBF Release................................................... 43
Figure 29 - Measurement Point of Size of IP Packets Sent to BIPB
..................................................................................... 46
Figure 30 - Measurement Point of Number of IP Packets Sent to
BIPB............................................................................... 47
Figure 31 - Measurement Point of Size of IP Packets Received
from BIPB ....................................................................... 48
Figure 32 - Measurement Point of Number of IP Packets Received
from BIPB ....................................................................... 48
Figure 33- Measurement Point of Size of IP Packets Sent to GIPB
..................................................................................... 49
Figure 34 - Measurement Point of Number of IP Packets Sent to
GIPB .............................................................................. 49
Figure 35 - Measurement Point of Size of IP Packets Received
from GIPB ....................................................................... 50
Figure 36 - Measurement Point of Number of IP Packets Received
from GIPB ....................................................................... 50
Figure 37 - Measurement Point of Number of Kbytes Carried by
DL EGPRS LLC Frame ........................................................ 51
Figure 38 - Measurement Point of Number of Kbytes Carried by
DL Signaling LLC Frame..................................................... 51

318 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B - Figures

Figure 39 - Measurement Point of Number of Kbytes Carried by


UL LLC Frame .................................................................. 52
Figure 40 - Measurement Point of Number of UL LLC Frames .. 52
Figure 41 - Measurement Point of Number of Bytes of DL GPRS
TBF LLC Frame................................................................. 53
Figure 42 - Measurement Point of Number of Bytes of DL EGPRS
TBF LLC Frame................................................................. 54
Figure 43 - Measurement Point of Number of Bytes of DL
Signaling TBF LLC Frame ................................................... 54
Figure 44 - Measurement Point of Number of Bytes of UL GPRS
TBF LLC Frame................................................................. 55
Figure 45 - Measurement Point of Number of Bytes of UL EGPRS
TBF LLC Frame................................................................. 55
Figure 46 - Measurement Point of Number of Bytes of UL
Signaling TBF LLC Frame ................................................... 56
Figure 47 - Measurement Point of Total Number of Completion of
GPRS UL Data TBF ............................................................ 56
Figure 48 - Measurement Point of Total Number of Completion of
GPRS DL Data TBF............................................................ 57
Figure 49 - Measurement Point of Total Number of Completion of
EGPRS UL Data TBF .......................................................... 57
Figure 50 - Measurement Point of Total Number of Completion of
EGPRS DL Data TBF .......................................................... 58
Figure 51 - Measurement Point of Number of Kbytes Carried by
DL GPRS LLC Frame.......................................................... 58
Figure 52 – Measurement Point of DL Pending RLC Block ........ 59
Figure 53 – Measurement Point of DL Retransmitted RLC Block60
Figure 54 – Measurement Point of DL First-Transmitted RLC Block
..................................................................................... 60
Figure 55 – Measurement Point of UL Pending RLC Block ........ 60
Figure 56 – Measurement Point of UL Retransmitted RLC Block 60
Figure 57 – Measurement Point of UL First-Transmitted RLC Block
..................................................................................... 61
Figure 58 – Measurement Point of Number of UL RLC Blocks Lost
..................................................................................... 62
Figure 59 – Measurement Point of Number of Standstill of GPRS
UL TBF Receiving Window .................................................. 63
Figure 60 – Measurement Point of Number of Standstill of GPRS
DL TBF Sending Window .................................................... 64
Figure 61 – Measurement Point of Number of Increment of DL
Coding Mode (EDGE RLC Block) .......................................... 65
Figure 62 – Measurement Point of Number of Increment of DL
Coding Mode (GPRS RLC Block) .......................................... 65

Confidential and Proprietary Information of ZTE CORPORATION 319


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Figure 63 – Measurement Point of Number of Increment of UL


Coding Mode.................................................................... 66
Figure 64 - Sending Instant Assignment Message by AGCH
Channel (1) ..................................................................... 76
Figure 65 - Sending Instant Assignment Message by AGCH
Channel (2) ..................................................................... 76
Figure 66 - Sending PS paging by PCH channel ..................... 76
Figure 67 - Sending CS paging by PCH channel..................... 77
Figure 68 – Sending Assignment Message by PAGCH Channel (1)
..................................................................................... 78
Figure 69 – Sending Assignment Message by PAGCH Channel (2)
..................................................................................... 78
Figure 70 – Number of Packet Channel Requests on PRACH .... 79
Figure 71 - Measurement Point of General Assignment
Executions....................................................................... 88
Figure 72 - Measurement Point of Assignments for Forced
Release Attempts ............................................................. 89
Figure 73 - Measurement Point of Assignment Executions for
Voice Channel due to Forced Release................................... 90
Figure 74 - Measurement Point of Handover for Forced Release
Attempts......................................................................... 91
Figure 75 – Measurement Point of Handover Executions for Voice
Channel due to Forced Release ........................................... 92
Figure 76 - Measurement Point of Assignments for Queuing
Attempts......................................................................... 93
Figure 77 – Measurement Point of Assignments for Execution for
Voice Channel due to Queuing ............................................ 94
Figure 78 – Measurement Point of Assignments for Directed
Retry Attempts................................................................. 96
Figure 79 – Measurement Point of Assignments for Execution for
Voice Channel due to Directed Retry.................................... 97
Figure 80 – Measurement Point of Assignment Failure due to
Circuit Obstruction on A-Interface ..................................... 105
Figure 81 – Measurement Point of Number of Assignment
Attempts due to Forced Release (Emergency Service).......... 107
Figure 82 – Measurement Point of Number of Forced Handover
Target not Found (Assignment Forced Handover) ................ 110
Figure 83 – Measurement Point of Number of Receiving Forced
Handover Failure Message from Low Priority User during Forced
Handover ...................................................................... 111
Figure 84 – Measurement Point of Number of Timeout for Wait
Resource (Assignment Forced Handover) ........................... 113
Figure 85 – Measurement Point of Number of Forced Release

320 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B - Figures

Target not Found (Assignment Forced Release) ................... 114


Figure 86 – Measurement Point of Number of Timeout for Wait
Resource (Assignment Forced Release) .............................. 115
Figure 87 - Directed Retry Judgment ................................. 120
Figure 88 - Handover Decision.......................................... 121
Figure 89 – HO_ENQUIRY Handover .................................. 125
Figure 90 – Traffic Handover ............................................ 126
Figure 91 – Forced Handover Judgment ............................. 128
Figure 92 - CS Channel Transfer Handover ......................... 140
Figure 93 – Call Drop due to A-Interface Failure in Immediate
Assignment Process ........................................................ 149
Figure 94 – Call Drop due to Radio Link Failure in Immediate
Assignment Process ........................................................ 150
Figure 95 – Call Drop due to LAPD Link Failure in Immediate
Assignment Process ........................................................ 151
Figure 96 – Call Drop due to OMC-R Forced Release in
Immediate Assignment Process ........................................ 151
Figure 97 – Call Drop due to Forced Release by Other Calls in
Immediate Assignment Process ........................................ 152
Figure 98 – Call Drop due to T3101 Overtime in Intra-cell
Handover ...................................................................... 153
Figure 99 – Call Drop due to A-Interface Failure in Assignment
Process ......................................................................... 156
Figure 100 – Call Drop due to LAPD Link Failure in Assignment
Process ......................................................................... 157
Figure 101 – Call Drop due to OMC-R Forced Release in
Assignment Process ........................................................ 158
Figure 102 – Call Drop due to Forced Release by Other Calls in
Assignment Process ........................................................ 159
Figure 103 – Call Drop due to Radio Link Failure in Assignment
Process ......................................................................... 161
Figure 104 – Call Drop due to SCCP Failure in Immediate
Assignment Process ........................................................ 171
Figure 105 – Call Drop due to Inter-BSC Handover Failure .... 173
Figure 106 – Measurement Point of Number of SDCCH Drops due
to eMLPP Forced Handover............................................... 176
Figure 107 – Reporting Measurement Data......................... 189
Figure 108 – BSC-Controlled Inter-Cell Outgoing Handover
Attempt ........................................................................ 207
Figure 109 – MSC-Controlled Outgoing Handover Attempts... 208
Figure 110 – MSC-Controlled Outgoing Handover Request
Failures Due to Unclear factors ......................................... 208

Confidential and Proprietary Information of ZTE CORPORATION 321


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

Figure 111 – MSC-Controlled Handover Request Failures ...... 209


Figure 112 – BSC-Controlled Inter-Cell Incoming handover
Attempts....................................................................... 211
Figure 113 – Forced release Attempts................................ 211
Figure 114 – Queuing Attempts ........................................ 212
Figure 115 – Forced-Handover Attempts ............................ 213
Figure 116 – Execution in Queuing.................................... 213
Figure 117 – Incoming Handover Queuing Expires............... 214
Figure 118 – Instance Release during Queuing ................... 214
Figure 119 – MSC-Controlled Incoming Handover Attempts .. 216
Figure 120 – Unsuccessful MSC-Controlled External Incoming
Handover ...................................................................... 217
Figure 121 – Successful BSC-Controlled Inter-Cell Incoming
Handover ...................................................................... 222
Figure 122 – Successful BSC-Controlled Inter-Cell Outgoing
Handover ...................................................................... 223
Figure 123 – BSC-Controlled Inter-Cell Outgoing Handover
Execution Flow............................................................... 226
Figure 124 – Intra-Cell Handover Attempt.......................... 241
Figure 125 – Successful Intra-Cell Handover ...................... 242
Figure 126 – MSC-Controlled Outgoing Handover ................ 245
Figure 127 – Successful MSC-Controlled Outgoing Handover. 246
Figure 128 – MSC-Controlled Incoming Handover................ 247
Figure 129 – MSC-Controlled Incoming Handover Success .... 247
Figure 130 – Intra-Cell Incoming Handover Attempt ............ 248
Figure 131 – Intra-Cell Incoming handover ........................ 248
Figure 132 – Successful Intra-Cell Handover ...................... 249
Figure 133 – BSC-Controlled Inter-Cell Incoming Handover .. 253
Figure 134 - BSC-controlled forced release on incoming
handover ...................................................................... 258
Figure 135 - BSC-controlled forced handover on incoming
handover ...................................................................... 259
Figure 136 - BSC-controlled queue on incoming handover .... 260
Figure 137 - MSC-controlled forced release attempt on incoming
handover ...................................................................... 261
Figure 138 - MSC-controlled forced release on incoming
handover ...................................................................... 261
Figure 139 - MSC-controlled forced handover attempt on
incoming handover ......................................................... 262
Figure 140 - MSC-controlled forced handover on incoming

322 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B - Figures

handover....................................................................... 263
Figure 141 - MSC-controlled queue attempt on incoming
handover....................................................................... 264
Figure 142 - MSC-controlled queue on incoming handover.... 264
Figure 143 - Forced handover target not found (BSC-controlled
inter-cell handover due to forced handover) ....................... 265
Figure 144 - Send forced handover request to lower PRI user
(BSC-controlled inter-cell handover due to forced handover). 266
Figure 145 - Recv failure from lower PRI user request resource
for forced handover (BSC-controlled inter-cell handover due to
forced handover)............................................................ 267
Figure 146 - Recv failure from lower PRI user request resource
for forced handover (BSC-controlled inter-cell handover due to
forced handover)............................................................ 268
Figure 147 - High PRI user time out for wait resource (BSC-
controlled inter-cell handover due to forced handover)......... 269
Figure 148 - Forced release target not found (BSC-controlled
inter-cell handover due to forced release) .......................... 269
Figure 149 - High PRI user time out for wait resource (BSC-
controlled inter-cell handover due to forced release)............ 270
Figure 150 – Radio Access Process .................................... 288

Confidential and Proprietary Information of ZTE CORPORATION 323


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

324 Confidential and Proprietary Information of ZTE CORPORATION


Tables

Table 1 – Manual Summary ...................................................i


Table 2 - Typographical Conventions..................................... iii
Table 3 - Mouse Operation Conventions ................................ iv
Table 4 – Usage Explanation of the Hazardous Substances in
ZXG10 iBSC (V6.20.10)..................................................... vii
Table 5 - DL Data TBF Measurement Counters ........................9
Table 6 – UL Data TBF Measurement Counters ...................... 27
Table 7 - Data Flow Measurement Counters .......................... 45
Table 8 – UL/DL RLC Statistic Measurement Counters ............ 61
Table 9 – PS Resource Used Statistic Measurement Counters .. 69
Table 10 – RMM Assignment Measurement Counters .............. 85
Table 11 - Handover Cause Measurement Counters ............. 117
Table 12 - RMM Call Drop Measurement Counters................ 145
Table 13 - Radio Resource Availability Measurement Counters187
Table 14 - General Handover Measurement Counters ........... 199
Table 15 - Adjacent Cell Handover Measurement Counters.... 277
Table 16 - Radio Access Measurement Counters .................. 288
Table 17 - Radio Measurement Counters ............................ 299

Confidential and Proprietary Information of ZTE CORPORATION 325


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

This page is intentionally blank.

326 Confidential and Proprietary Information of ZTE CORPORATION


Index

C901000001 ...................... 11 C901010050 ...................... 42


C901000005 ...................... 11 C901010056 ...................... 42
C901000006 ...................... 12 C901020001 ...................... 46
C901000009 ...................... 12 C901020002 ...................... 47
C901000010 ...................... 13 C901020003 ...................... 47
C901000011 ...................... 14 C901020004 ...................... 48
C901000012 ...................... 15 C901020005 ...................... 48
C901000013 ...................... 16 C901020006 ...................... 49
C901000014 ...................... 17 C901020007 ...................... 49
C901000015 ...................... 17 C901020008 ...................... 50
C901000023 ...................... 18 C901020009 ...................... 50
C901000027 ...................... 18 C901020014 ...................... 51
C901000028 ...................... 19 C901020019 ...................... 52
C901000031 ...................... 19 C901020020 ...................... 52
C901000032 ...................... 19 C901020021 ...................... 53
C901000033 ...................... 20 C901020022 ...................... 53
C901000034 ...................... 20 C901020023 ...................... 54
C901000035 ...................... 21 C901020024 ...................... 54
C901000036 ...................... 21 C901020025 ...................... 55
C901000037 ...................... 22 C901020026 ...................... 55
C901000045 ...................... 23 C901020031 ...................... 56
C901000046 ...................... 23 C901020034 ...................... 56
C901000047 ...................... 24 C901020041 ...................... 57
C901000048 ...................... 24 C901020044 ...................... 57
C901000050 ...................... 24 C901020050 ...................... 58
C901000052 ...................... 25 C901030041 ...................... 61
C901000058 ...................... 25 C901030042 ...................... 62
C901010001 ...................... 28 C901030083 ...................... 62
C901010002 ...................... 29 C901030084 ...................... 62
C901010006 ...................... 30 C901030085 ...................... 63
C901010007 ...................... 30 C901030086 ...................... 63
C901010010 ...................... 30 C901030087 ...................... 63
C901010011 ...................... 31 C901030088 ...................... 64
C901010012 ...................... 32 C901030089 ...................... 64
C901010013 ...................... 33 C901030090 ...................... 65
C901010014 ...................... 34 C901030091 ...................... 65
C901010022 ...................... 34 C901030092 ...................... 66
C901010023 ...................... 35 C901030093 ...................... 66
C901010027 ...................... 35 C901030094 ...................... 67
C901010028 ...................... 36 C901030095 ...................... 67
C901010031 ...................... 36 C901040001 ...................... 70
C901010032 ...................... 37 C901040002 ...................... 71
C901010033 ...................... 38 C901040004 ...................... 71
C901010034 ...................... 38 C901040005 ...................... 71
C901010035 ...................... 40 C901040006 ...................... 72
C901010043 ...................... 40 C901040009 ...................... 72
C901010044 ...................... 40 C901040010 ...................... 73
C901010045 ...................... 41 C901040011 ...................... 73
C901010046 ...................... 41 C901040012 ...................... 74
C901010048 ...................... 41 C901040013 ...................... 74

Confidential and Proprietary Information of ZTE CORPORATION 327


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901040014 ...................... 75 C901060003..................... 121


C901040018 ...................... 75 C901060004..................... 121
C901040019 ...................... 76 C901060005..................... 121
C901040020 ...................... 77 C901060006..................... 122
C901040021 ...................... 77 C901060007..................... 122
C901040022 ...................... 77 C901060008..................... 122
C901040023 ...................... 78 C901060009..................... 123
C901040024 ...................... 78 C901060010..................... 123
C901040025 ...................... 79 C901060011..................... 124
C901040026 ...................... 79 C901060012..................... 124
C901040027 ...................... 80 C901060013..................... 125
C901040028 ...................... 80 C901060014..................... 125
C901040029 ...................... 80 C901060015..................... 126
C901040030 ...................... 80 C901060016..................... 126
C901040031 ...................... 81 C901060017..................... 127
C901040032 ...................... 81 C901060018..................... 127
C901040033 ...................... 82 C901060019..................... 127
C901040034 ...................... 82 C901060020..................... 128
C901040035 ...................... 82 C901060021..................... 129
C901040036 ...................... 83 C901060022..................... 129
C901040037 ...................... 83 C901060023..................... 129
C901040038 ...................... 83 C901060024..................... 130
C901050001 ...................... 88 C901060035..................... 130
C901050002 ...................... 88 C901060036..................... 130
C901050003 ...................... 89 C901060037..................... 131
C901050004 ...................... 90 C901060038..................... 131
C901050005 ...................... 91 C901060039..................... 132
C901050006 ...................... 92 C901060040..................... 132
C901050007 ...................... 93 C901060041..................... 132
C901050008 ...................... 94 C901060042..................... 133
C901050009 ...................... 94 C901060043..................... 133
C901050010 ...................... 95 C901060044..................... 134
C901050011 ...................... 96 C901060045..................... 134
C901050012 ...................... 97 C901060046..................... 134
C901050013 ...................... 97 C901060058..................... 135
C901050014 ...................... 98 C901060059..................... 135
C901050015 ...................... 98 C901060060..................... 136
C901050016 ...................... 99 C901060061..................... 136
C901050017 ...................... 99 C901060062..................... 136
C901050018 .....................100 C901060063..................... 137
C901050019 .....................100 C901060064..................... 137
C901050020 .....................100 C901060065..................... 137
C901050021 .....................101 C901060066..................... 138
C901050022 .....................101 C901060067..................... 138
C901050023 .....................101 C901060068..................... 139
C901050024 .....................102 C901060069..................... 139
C901050025 .....................102 C901060070..................... 140
C901050026 .....................103 C901060071..................... 140
C901050027 .....................103 C901060072..................... 140
C901050028 .....................103 C901060073..................... 141
C901050029 .....................104 C901060074..................... 141
C901050030 .....................104 C901060075..................... 142
C901050031 .....................104 C901060076..................... 142
C901050032 .....................105 C901060077..................... 142
C901050033 .....................105 C901060078..................... 143
C901050034106, 107, 108, 109, C901070001..................... 149
110, 111, 112, 113, 114, C901070002..................... 149
115 C901070003..................... 150
C901060001 .....................120 C901070004..................... 151
C901060002 .....................120 C901070005..................... 151

328 Confidential and Proprietary Information of ZTE CORPORATION


Index

C901070007 .................... 152 C901070078 .................... 181


C901070008 .................... 153 C901070079 .................... 181
C901070009 .................... 153 C901070080 .................... 181
C901070010 .................... 154 C901070081 .................... 182
C901070011 .................... 154 C901070082 .................... 182
C901070012 .................... 155 C901070083 .................... 183
C901070014 .................... 155 C901070084 .................... 183
C901070015 .................... 155 C901070085 .................... 183
C901070017 .................... 157 C901070086 .................... 184
C901070018 .................... 157 C901070087 .................... 184
C901070019 .................... 158 C901070088 .................... 184
C901070021 .................... 159 C901080003 .................... 188
C901070022 .................... 160 C901080004 .................... 189
C901070023 .................... 160 C901080006 .................... 189
C901070024 .................... 161 C901080008 .................... 190
C901070025 .................... 162 C901080011 .................... 190
C901070026 .................... 162 C901080012 .................... 190
C901070028 .................... 162 C901080014 .................... 191
C901070029 .................... 163 C901080016 .................... 191
C901070030 .................... 163 C901080017 .................... 192
C901070031 .................... 164 C901080018 .................... 193
C901070032 .................... 164 C901080022 .................... 193
C901070033 .................... 165 C901080024 .................... 194
C901070035 .................... 165 C901080025 .................... 194
C901070036 .................... 165 C901080026 .................... 195
C901070038 .................... 166 C901080027 .................... 196
C901070039 .................... 166 C901080030 .................... 196
C901070040 .................... 167 C901080032 .................... 197
C901070042 .................... 167 C901090001 .................... 206
C901070043 .................... 168 C901090004 .................... 207
C901070044 .................... 168 C901090005 .................... 208
C901070045 .................... 168 C901090006 .................... 209
C901070046 .................... 169 C901090007 .................... 209
C901070047 .................... 169 C901090008 .................... 210
C901070049 .................... 170 C901090011 .................... 210
C901070053 .................... 170 C901090013 .................... 211
C901070054 .................... 171 C901090015 .................... 212
C901070055 .................... 172 C901090017 .................... 212
C901070056 .................... 173 C901090020 .................... 213
C901070057 .................... 173 C901090021 .................... 214
C901070058 .................... 174 C901090022 .................... 215
C901070059 .................... 174 C901090023 .................... 215
C901070060 .................... 174 C901090024 .................... 216
C901070061 .................... 175 C901090025 .................... 216
C901070062 .................... 175 C901090026 .................... 217
C901070063 .................... 175 C901090027 .................... 217
C901070064 .................... 176 C901090028 .................... 218
C901070065 .................... 176 C901090030 .................... 218
C901070066 .................... 177 C901090032 .................... 218
C901070067 .................... 177 C901090034 .................... 219
C901070068 .................... 177 C901090037 .................... 219
C901070069 .................... 178 C901090038 .................... 220
C901070070 .................... 178 C901090039 .................... 220
C901070071 .................... 178 C901090040 .................... 221
C901070072 .................... 179 C901090041 .................... 221
C901070073 .................... 179 C901090042 .................... 222
C901070074 .................... 179 C901090043 .................... 222
C901070075 .................... 180 C901090044 .................... 223
C901070076 .................... 180 C901090045 .................... 223
C901070077 .................... 180 C901090046 .................... 224

Confidential and Proprietary Information of ZTE CORPORATION 329


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume II)

C901090047 .....................224 C901090125..................... 249


C901090048 .....................224 C901090126..................... 249
C901090049 .....................225 C901090127..................... 250
C901090052 .....................225 C901090128..................... 250
C901090053 .....................226 C901090129..................... 250
C901090054 .....................226 C901090130..................... 251
C901090055 .....................227 C901090131..................... 251
C901090058 .....................227 C901090132..................... 252
C901090059 .....................227 C901090133..................... 252
C901090060 .....................228 C901090134..................... 252
C901090061 .....................228 C901090135..................... 253
C901090062 .....................229 C901090136..................... 253
C901090063 .....................229 C901090137..................... 253
C901090064 .....................229 C901090138..................... 254
C901090065 .....................230 C901090139..................... 254
C901090066 .....................230 C901090140..................... 255
C901090067 .....................231 C901090141..................... 255
C901090068 .....................231 C901090142..................... 255
C901090069 .....................231 C901090145..................... 256
C901090072 .....................232 C901090148..................... 256
C901090073 .....................232 C901090149..................... 257
C901090074 .....................233 C901090150..................... 257
C901090075 .....................233 C901090151..................... 258
C901090078 .....................233 C901090152..................... 258
C901090079 .....................234 C901090153..................... 259
C901090080 .....................234 C901090154..................... 259
C901090081 .....................235 C901090155..................... 260
C901090084 .....................235 C901090156..................... 261
C901090085 .....................235 C901090157..................... 262
C901090086 .....................236 C901090158..................... 262
C901090087 .....................236 C901090159..................... 263
C901090090 .....................237 C901090160..................... 264
C901090091 .....................237 C901090161..................... 265
C901090092 .....................237 C901090162..................... 265
C901090093 .....................238 C901090163..................... 266
C901090096 .....................238 C901090164..................... 267
C901090097 .....................239 C901090165..................... 268
C901090098 .....................239 C901090166..................... 269
C901090099 .....................239 C901090167..................... 270
C901090102 .....................240 C901090168..................... 270
C901090103 .....................240 C901090169..................... 271
C901090104 .....................241 C901090170..................... 271
C901090105 .....................241 C901090171..................... 272
C901090108 .....................242 C901090172..................... 272
C901090109 .....................242 C901090173..................... 273
C901090110 .....................242 C901090174..................... 273
C901090111 .....................243 C901090175..................... 274
C901090112 .....................243 C901090176..................... 274
C901090113 .....................244 C901090177..................... 274
C901090114 .....................244 C901090178..................... 275
C901090115 .....................244 C901090179..................... 275
C901090116 .....................245 C901100001..................... 278
C901090117 .....................245 C901100002..................... 279
C901090118 .....................246 C901100003..................... 279
C901090119 .....................246 C901100004..................... 280
C901090120 .....................246 C901100005..................... 280
C901090121 .....................247 C901100006..................... 280
C901090122 .....................248 C901100007..................... 281
C901090123 .....................248 C901100008..................... 281
C901090124 .....................249 C901100009..................... 282

330 Confidential and Proprietary Information of ZTE CORPORATION


Index

C901100010 .................... 282 C901120002 .................... 301


C901100011 .................... 282 C901120003 .................... 302
C901100012 .................... 283 C901120004 .................... 302
C901100013 .................... 283 C901120005 .................... 302
C901100014 .................... 284 C901120006 .................... 303
C901100015 .................... 284 C901120007 .................... 303
C901100016 ............. 284, 285 C901120008 .................... 303
C901110001 .................... 289 C901120009 .................... 304
C901110003 .................... 290 C901120010 .................... 304
C901110006 .................... 290 C901120011 .................... 304
C901110008 .................... 290 C901120012 .................... 305
C901110009 .................... 291 C901120013 .................... 305
C901110010 .................... 291 C901120014 .................... 305
C901110011 .................... 291 C901120015 .................... 306
C901110012 .................... 292 C901120016 .................... 306
C901110013 .................... 292 C901120017 .................... 306
C901110014 .................... 292 C901120018 .................... 307
C901110015 .................... 293 C901120024 .................... 307
C901110016 .................... 293 C901120030 .................... 307
C901110017 .................... 293 C901120031 .................... 308
C901110018 .................... 294 C901120032 .................... 308
C901110019 .................... 294 C901120033 .................... 308
C901110020 .................... 294 C901120034 .................... 308
C901110021 .................... 295 C901120035 .................... 309
C901110022 .................... 295 C901120052 .................... 309
C901110023 .................... 295 C901120053 .................... 309
C901110024 .................... 296 C901120054 .................... 309
C901110026 .................... 296 C901120055 .................... 309
C901110027 .................... 296 C901120056 .................... 310
C901110028 .................... 297 C901120057 .................... 310
C901110029 .................... 297 C901120058 .................... 310
C901110031 .................... 297 C901120059 .................... 310
C901110032 .................... 298 C901120060 .................... 311
C901110033 .................... 298 C901120061 .................... 311
C901120001 .................... 301 C901120062 .................... 311

Confidential and Proprietary Information of ZTE CORPORATION 331


ZXG10 iBSC
Base Station Controller
Performance Counter Reference (Volume III)

Version 6.20.10

ZTE CORPORATION
ZTE Plaza, Keji Road South,
Hi-Tech Industrial Park,
Nanshan District, Shenzhen,
P. R. China
518057
Tel: (86) 755 26771900 800-9830-9830
Fax: (86) 755 26772236
URL: http://support.zte.com.cn
E-mail: doc@zte.com.cn
This page is intentionally blank.
Contents

About This Manual ............................................................ i


Purpose ................................................................................ i
Intended Audience ................................................................. i
Prerequisite Skill and Knowledge .............................................. i
What Is in This Manual ........................................................... i
Related Documentation.......................................................... ii
Conventions ........................................................................ iii
How to Get in Touch ............................................................. iv

Declaration of RoHS Compliance..................................... v

Chapter 1.......................................................................... 7

Sub Cell Statistics ............................................................ 7


Overview ............................................................................. 7
Sub Cell Statistics Counter Index ............................................ 7
C901130001 ...................................................................... 10
C901130002 ...................................................................... 10
C901130003 ...................................................................... 11
C901130004 ...................................................................... 11
C901130005 ...................................................................... 11
C901130006 ...................................................................... 12
C901130007 ...................................................................... 12
C901130008 ...................................................................... 13
C901130009 ...................................................................... 13
C901130010 ...................................................................... 14
C901130011 ...................................................................... 14
C901130012 ...................................................................... 15
C901130013 ...................................................................... 15
C901130014 ...................................................................... 15
C901130015 ...................................................................... 16
C901130016 ...................................................................... 16
C901130017 ...................................................................... 17
C901130018.......................................................................18
C901130019.......................................................................18
C901130020.......................................................................19
C901130021.......................................................................19
C901130022.......................................................................20
C901130023.......................................................................20
C901130024.......................................................................21
C901130025.......................................................................21
C901130026.......................................................................22
C901130027.......................................................................22
C901130028.......................................................................23
C901130029.......................................................................23
C901130030.......................................................................24
C901130031.......................................................................24
C901130032.......................................................................25
C901130033.......................................................................25
C901130034.......................................................................26
C901130035.......................................................................26
C901130036.......................................................................27
C901130037.......................................................................27
C901130038.......................................................................28
C901130039.......................................................................28
C901130040.......................................................................29
C901130041.......................................................................30
C901130042.......................................................................30
C901130043.......................................................................31
C901130044.......................................................................31
C901130045.......................................................................32
C901130046.......................................................................32
C901130047.......................................................................33
C901130048.......................................................................33
C901130049.......................................................................34
C901130050.......................................................................34
C901130051.......................................................................35
C901130052.......................................................................35
C901130053.......................................................................36
C901130054.......................................................................36
C901130055.......................................................................37
C901130056.......................................................................37
C901130057 ...................................................................... 38
C901130058 ...................................................................... 38
C901130059 ...................................................................... 39
C901130060 ...................................................................... 39

Chapter 2........................................................................ 41

MS TA Measurement ...................................................... 41
Overview ........................................................................... 41
MS TA Measurement Counter Index ....................................... 41
C901140001 ...................................................................... 42
C901140002 ...................................................................... 43
C901140003 ...................................................................... 43
C901140004 ...................................................................... 43
C901140005 ...................................................................... 44
C901140006 ...................................................................... 44
C901140007 ...................................................................... 44
C901140008 ...................................................................... 45
C901140009 ...................................................................... 45
C901140010 ...................................................................... 45
C901140011 ...................................................................... 46
C901140012 ...................................................................... 46
C901140013 ...................................................................... 46
C901140014 ...................................................................... 47
C901140015 ...................................................................... 47
C901140016 ...................................................................... 47
C901140017 ...................................................................... 48
C901140018 ...................................................................... 48
C901140019 ...................................................................... 48
C901140020 ...................................................................... 49
C901140021 ...................................................................... 49
C901140022 ...................................................................... 49
C901140023 ...................................................................... 50
C901140024 ...................................................................... 50
C901140025 ...................................................................... 50
C901140026 ...................................................................... 51
C901140027 ...................................................................... 51
C901140028 ...................................................................... 51
C901140029 ...................................................................... 52
C901140030 ...................................................................... 52
C901140031.......................................................................52
C901140032.......................................................................53
C901140033.......................................................................53

Chapter 3........................................................................ 55

SAPI3 Measurement ...................................................... 55


Overview ...........................................................................55
SAPI3 Measurement Counter Index ........................................55
C901150001.......................................................................56
C901150002.......................................................................57
C901150004.......................................................................58
C901150005.......................................................................58
C901150006.......................................................................58
C901150007.......................................................................59
C901150009.......................................................................60
C901150010.......................................................................60
C901150011.......................................................................60
C901150012.......................................................................61
C901150014.......................................................................61
C901150015.......................................................................61
C901150016.......................................................................62
C901150017.......................................................................64
C901150018.......................................................................65
C901150019.......................................................................65
C901150020.......................................................................65
C901150021.......................................................................66
C901150022.......................................................................66
C901150023.......................................................................66
C901150024.......................................................................67
C901150025.......................................................................67

Chapter 4........................................................................ 69

Uplink and Downlink PACCH Statistics..........................69


Overview ...........................................................................69
UL and DL PACCH Statistics Counter Index..............................69
C901160001.......................................................................70
C901160002.......................................................................71
C901160003.......................................................................71
C901160004.......................................................................72
C901160005 ...................................................................... 73
C901160006 ...................................................................... 73
C901160007 ...................................................................... 74
C901160008 ...................................................................... 74
C901160009 ...................................................................... 75
C901160010 ...................................................................... 75
C901160011 ...................................................................... 76
C901160012 ...................................................................... 77
C901160013 ...................................................................... 77
C901160014 ...................................................................... 78
C901160017 ...................................................................... 78
C901160018 ...................................................................... 79
C901160019 ...................................................................... 79
C901160020 ...................................................................... 79
C901160021 ...................................................................... 80
C901160022 ...................................................................... 81
C901160023 ...................................................................... 81
C901160024 ...................................................................... 82
C901160025 ...................................................................... 82
C901160026 ...................................................................... 83
C901160027 ...................................................................... 84

Chapter 5........................................................................ 85

Downlink GPRS Data TBF Statistics .............................. 85


Overview ........................................................................... 85
DL GPRS Data TBF Statistics Counter Index ............................ 85
C901170002 ...................................................................... 88
C901170003 ...................................................................... 88
C901170004 ...................................................................... 89
C901170005 ...................................................................... 89
C901170007 ...................................................................... 89
C901170008 ...................................................................... 90
C901170009 ...................................................................... 91
C901170010 ...................................................................... 92
C901170011 ...................................................................... 93
C901170012 ...................................................................... 93
C901170013 ...................................................................... 94
C901170014 ...................................................................... 95
C901170015 ...................................................................... 95
C901170016.......................................................................96
C901170017.......................................................................96
C901170018.......................................................................97
C901170019.......................................................................97
C901170020.......................................................................97
C901170023.......................................................................97
C901170024.......................................................................98
C901170025.......................................................................99
C901170026..................................................................... 100
C901170027..................................................................... 100
C901170028..................................................................... 101
C901170029..................................................................... 101
C901170030..................................................................... 101
C901170031..................................................................... 102
C901170032..................................................................... 102
C901170033..................................................................... 103
C901170036..................................................................... 103
C901170037..................................................................... 103
C901170038..................................................................... 104
C901170039..................................................................... 105
C901170040..................................................................... 106
C901170041..................................................................... 106
C901170042..................................................................... 107
C901170043..................................................................... 107
C901170044..................................................................... 108
C901170045..................................................................... 108
C901170046..................................................................... 108
C901170047..................................................................... 108
C901170048..................................................................... 109
C901170049..................................................................... 109
C901170050..................................................................... 110
C901170051..................................................................... 110
C901170052..................................................................... 111
C901170053..................................................................... 112
C901170054..................................................................... 112
C901170055..................................................................... 113
C901170056..................................................................... 113
C901170057..................................................................... 113
C901170058..................................................................... 114
C901170059 .................................................................... 114

Chapter 6...................................................................... 117

Downlink EGPRS Data TBF Statistics ..........................117


Overview ......................................................................... 117
DL EGPRS Data TBF Statistics Counter Index ........................ 117
C901180002 .................................................................... 120
C901180003 .................................................................... 120
C901180004 .................................................................... 121
C901180005 .................................................................... 121
C901180007 .................................................................... 121
C901180008 .................................................................... 121
C901180009 .................................................................... 122
C901180010 .................................................................... 123
C901180011 .................................................................... 123
C901180012 .................................................................... 123
C901180013 .................................................................... 124
C901180014 .................................................................... 124
C901180015 .................................................................... 125
C901180016 .................................................................... 125
C901180017 .................................................................... 125
C901180018 .................................................................... 126
C901180019 .................................................................... 126
C901180020 .................................................................... 126
C901180023 .................................................................... 126
C901180024 .................................................................... 127
C901180025 .................................................................... 127
C901180026 .................................................................... 128
C901180027 .................................................................... 128
C901180028 .................................................................... 128
C901180029 .................................................................... 129
C901180030 .................................................................... 129
C901180031 .................................................................... 130
C901180032 .................................................................... 130
C901180033 .................................................................... 130
C901180036 .................................................................... 130
C901180037 .................................................................... 131
C901180038 .................................................................... 131
C901180039 .................................................................... 132
C901180040..................................................................... 132
C901180041..................................................................... 133
C901180042..................................................................... 133
C901180043..................................................................... 134
C901180044..................................................................... 134
C901180045..................................................................... 134
C901180046..................................................................... 134
C901180047..................................................................... 135
C901180048..................................................................... 135
C901180049..................................................................... 135
C901180050..................................................................... 136
C901180051..................................................................... 136
C901180052..................................................................... 136
C901180053..................................................................... 137
C901180054..................................................................... 137

Chapter 7......................................................................139

Uplink GPRS Data TBF Statistics..................................139


Overview ......................................................................... 139
UL GPRS Data TBF Statistics Counter Index........................... 139
C901190002..................................................................... 144
C901190003..................................................................... 144
C901190004..................................................................... 145
C901190005..................................................................... 145
C901190006..................................................................... 145
C901190007..................................................................... 146
C901190008..................................................................... 147
C901190009..................................................................... 147
C901190010..................................................................... 148
C901190011..................................................................... 148
C901190012..................................................................... 149
C901190013..................................................................... 150
C901190015..................................................................... 150
C901190016..................................................................... 152
C901190017..................................................................... 153
C901190018..................................................................... 154
C901190019..................................................................... 155
C901190020..................................................................... 156
C901190021..................................................................... 157
C901190022 .................................................................... 157
C901190023 .................................................................... 158
C901190024 .................................................................... 159
C901190025 .................................................................... 159
C901190026 .................................................................... 160
C901190027 .................................................................... 161
C901190028 .................................................................... 161
C901190029 .................................................................... 162
C901190030 .................................................................... 162
C901190031 .................................................................... 162
C901190032 .................................................................... 163
C901190033 .................................................................... 163
C901190034 .................................................................... 163
C901190035 .................................................................... 164
C901190038 .................................................................... 164
C901190039 .................................................................... 165
C901190040 .................................................................... 165
C901190041 .................................................................... 166
C901190042 .................................................................... 166
C901190043 .................................................................... 166
C901190044 .................................................................... 167
C901190045 .................................................................... 167
C901190046 .................................................................... 168
C901190047 .................................................................... 168
C901190048 .................................................................... 168
C901190051 .................................................................... 168
C901190052 .................................................................... 169
C901190053 .................................................................... 169
C901190054 .................................................................... 170
C901190055 .................................................................... 170
C901190056 .................................................................... 171
C901190057 .................................................................... 171
C901190058 .................................................................... 172
C901190059 .................................................................... 172
C901190060 .................................................................... 172
C901190061 .................................................................... 172
C901190062 .................................................................... 173
C901190064 .................................................................... 173
C901190065 .................................................................... 173
C901190066..................................................................... 174
C901190067..................................................................... 175
C901190068..................................................................... 176
C901190069..................................................................... 176
C901190070..................................................................... 177
C901190071..................................................................... 177
C901190072..................................................................... 178
C901190073..................................................................... 178
C901190074..................................................................... 178
C901190075..................................................................... 178
C901190076..................................................................... 179
C901190077..................................................................... 179
C901190078..................................................................... 179
C901190079..................................................................... 180
C901190080..................................................................... 180
C901190081..................................................................... 180
C901190082..................................................................... 181
C901190083..................................................................... 181
C901190084..................................................................... 181
C901190085..................................................................... 182
C901190086..................................................................... 182
C901190087..................................................................... 183

Chapter 8......................................................................185

Uplink EGPRS Data TBF Statistics................................185


Overview ......................................................................... 185
UL GPRS Data TBF Statistics Counter Index........................... 185
C901200002..................................................................... 190
C901200003..................................................................... 190
C901200004..................................................................... 191
C901200005..................................................................... 191
C901200006..................................................................... 191
C901200007..................................................................... 192
C901200008..................................................................... 192
C901200009..................................................................... 193
C901200010..................................................................... 193
C901200011..................................................................... 193
C901200012..................................................................... 193
C901200013..................................................................... 194
C901200015 .................................................................... 195
C901200016 .................................................................... 196
C901200017 .................................................................... 196
C901200018 .................................................................... 197
C901200019 .................................................................... 198
C901200020 .................................................................... 198
C901200021 .................................................................... 199
C901200022 .................................................................... 199
C901200023 .................................................................... 199
C901200024 .................................................................... 199
C901200025 .................................................................... 200
C901200026 .................................................................... 201
C901200027 .................................................................... 201
C901200028 .................................................................... 202
C901200029 .................................................................... 202
C901200030 .................................................................... 203
C901200031 .................................................................... 203
C901200032 .................................................................... 204
C901200033 .................................................................... 204
C901200034 .................................................................... 204
C901200035 .................................................................... 205
C901200038 .................................................................... 205
C901200039 .................................................................... 205
C901200040 .................................................................... 206
C901200041 .................................................................... 206
C901200042 .................................................................... 206
C901200043 .................................................................... 207
C901200044 .................................................................... 207
C901200045 .................................................................... 208
C901200046 .................................................................... 208
C901200047 .................................................................... 208
C901200048 .................................................................... 208
C901200051 .................................................................... 209
C901200052 .................................................................... 209
C901200053 .................................................................... 210
C901200054 .................................................................... 210
C901200055 .................................................................... 210
C901200056 .................................................................... 211
C901200057 .................................................................... 211
C901200058..................................................................... 212
C901200059..................................................................... 212
C901200060..................................................................... 212
C901200061..................................................................... 213
C901200062..................................................................... 213
C901200064..................................................................... 213
C901200065..................................................................... 213
C901200066..................................................................... 214
C901200067..................................................................... 214
C901200068..................................................................... 215
C901200069..................................................................... 215
C901200070..................................................................... 215
C901200071..................................................................... 216
C901200072..................................................................... 216
C901200073..................................................................... 217
C901200074..................................................................... 217
C901200075..................................................................... 217
C901200076..................................................................... 217
C901200077..................................................................... 218
C901200078..................................................................... 218
C901200079..................................................................... 218
C901200080..................................................................... 219
C901200081..................................................................... 219
C901200082..................................................................... 219
C901200083..................................................................... 220
C901200084..................................................................... 220
C901200085..................................................................... 221
C901200086..................................................................... 221
C901200087..................................................................... 221

Chapter 9......................................................................223

BSSGP Flow Statistic....................................................223


Overview ......................................................................... 223
BSSGP Flow Statistics Counter Index.................................... 223
C901210001..................................................................... 224
C901210002..................................................................... 225
C901210003..................................................................... 225
C901210004..................................................................... 226
C901210005..................................................................... 226
C901210006 .................................................................... 226
C901210007 .................................................................... 227
C901210008 .................................................................... 227
C901210009 .................................................................... 227
C901210010 .................................................................... 228
C901210011 .................................................................... 228
C901210012 .................................................................... 228
C901210013 .................................................................... 229
C901210014 .................................................................... 229
C901210015 .................................................................... 230
C901210016 .................................................................... 230
C901210017 .................................................................... 230
C901210018 .................................................................... 231
C901210019 .................................................................... 231
C901210020 .................................................................... 232
C901210021 .................................................................... 232
C901210022 .................................................................... 233
C901210023 .................................................................... 233

Chapter 10.................................................................... 235

TRX Measurement........................................................235
Overview ......................................................................... 235
TRX Measurement Counter Index ........................................ 235
C901230001 .................................................................... 238
C901230002 .................................................................... 238
C901230003 .................................................................... 238
C901230004 .................................................................... 239
C901230005 .................................................................... 239
C901230006 .................................................................... 240
C901230007 .................................................................... 240
C901230008 .................................................................... 240
C901230009 .................................................................... 241
C901230010 .................................................................... 241
C901230011 .................................................................... 241
C901230012 .................................................................... 242
C901230013 .................................................................... 243
C901230014 .................................................................... 243
C901230015 .................................................................... 244
C901230016 .................................................................... 244
C901230017..................................................................... 244
C901230018..................................................................... 245
C901230019..................................................................... 245
C901230020..................................................................... 245
C901230021..................................................................... 246
C901230022..................................................................... 246
C901230023..................................................................... 247
C901230024..................................................................... 247
C901230025..................................................................... 247
C901230026..................................................................... 248
C901230027..................................................................... 248
C901230028..................................................................... 248
C901230029..................................................................... 249
C901230030..................................................................... 249
C901230031..................................................................... 249
C901230032..................................................................... 249
C901230033..................................................................... 250
C901230034..................................................................... 250
C901230035..................................................................... 250
C901230036..................................................................... 250
C901230037..................................................................... 251
C901230038..................................................................... 251
C901230039..................................................................... 251
C901230040..................................................................... 251
C901230041..................................................................... 252
C901230042..................................................................... 252
C901230043..................................................................... 252
C901230044..................................................................... 253
C901230045..................................................................... 253
C901230046..................................................................... 253
C901230047..................................................................... 253
C901230048..................................................................... 254
C901230049..................................................................... 254
C901230050..................................................................... 254
C901230051..................................................................... 254
C901230052..................................................................... 255
C901230053..................................................................... 255
C901230054..................................................................... 255
C901230055..................................................................... 255
C901230056 .................................................................... 256
C901230057 .................................................................... 256
C901230058 .................................................................... 256
C901230059 .................................................................... 256
C901230060 .................................................................... 257
C901230061 .................................................................... 257
C901230062 .................................................................... 257

Appendix A ................................................................... 259

Abbreviations ............................................................... 259

Appendix B ................................................................... 263

Figures.......................................................................... 263

Tables ........................................................................... 269

Index ............................................................................ 271


This page is intentionally blank.
About This Manual

Purpose
This manual provides procedures and guidelines that support the
operation of the ZXG10 iBSC (V6.20.10).

Intended Audience
This manual is intended for engineers and technicians who
perform operation activities on the ZXG10 iBSC (V6.20.10).

Prerequisite Skill and Knowledge


To use this manual effectively, users should have a general
understanding of wireless telecommunications technology.
Familiarity with the following is helpful:
„ ZXG10 system and its various components
„ GSM BSS components and processes
„ Local operating procedures

What Is in This Manual


This manual contains the following sections:

TABLE 1 – M ANUAL SUMMARY

Section Summary
Chapter 1, Sub Cell Introduces the detailed information about
Statistics counters related to sub cell statistics.
Chapter 2, MS TA Introduces the detailed information about
Measurement counters related to MS TA measurement.
Chapter 3, SAPI3 Introduces the detailed information about
Measurement counters related to SAPI3 measurement.

Confidential and Proprietary Information of ZTE CORPORATION i


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Section Summary
Chapter 4, Uplink and Introduces the detailed information about
Downlink PACCH counters related to uplink and downlink
Statistics PACCH statistics.

Chapter 5, Downlink Introduces the detailed information about


GPRS data TBF counters related to downlink GPRS data
statistic TBF statistic.
Chapter 6, Downlink Introduces the detailed information about
EGPRS data TBF counters related to downlink EGPRS data
statistic TBF statistic.
Chapter 7, Uplink GPRS Introduces the detailed information about
data TBF statistics counters related to uplink GPRS data TBF
statistics.
Chapter 8, Uplink Introduces the detailed information about
EGPRS data TBF counters related to uplink EGPRS data TBF
statistics statistics.
Chapter 9, BSSGP Flow Introduces the detailed information about
Statistic counters related to BSSGP flow statistic.

Chapter 10, TRX Introduces the detailed information about


Measurement counters related to TRX measurement.

Appendix A, Lists all the abbreviations used in this


Abbreviations manual.

Appendix B, Figures Lists all the figures and tables used in this
and Tables manual.

Index Index of terms and definitions appeared in


this manual.

Related Documentation
The following documentation is related to this manual:
„ ZXG10 iBSC (V6.20.10) Base Station Controller
Documentation Guide
„ ZXG10 iBSC (V6.20.10) Base Station Controller System
Description
„ ZXG10 iBSC (V6.20.10) Base Station Controller Hardware
Description
„ ZXG10 iBSC (V6.20.10) Base Station Controller Hardware
Installation Guide
„ ZXG10 iBSC (V6.20.10) Base Station Controller Routine
Maintenance
„ ZXG10 iBSC (V6.20.10) Base Station Controller Emergency
Maintenance

ii Confidential and Proprietary Information of ZTE CORPORATION


About This Manual

„ ZXG10 iBSC (V6.20.10) Base Station Controller


Troubleshooting
„ ZXG10 iBSC (V6.20.10) Base Station Controller KPI
Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem OMM
Software Installation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Initial
Configuration Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Feature
Configuration Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Radio
Parameters Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Ground
Parameters Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem MML
Command Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Signaling
Tracing Operation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Diagnosis
Test Operation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Alarm
Handling Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Notification
Handling Reference

Conventions
Typographical ZTE documents employ the following typographical conventions.
Conventions
TABLE 2 - TYPOGRAPHIC AL CONVENTIONS

Typeface Meaning
Italics References to other Manuals and documents.
“Quotes” Links on screens.
Bold Menus, menu options, function names, input
fields, radio button names, check boxes, drop-
down lists, dialog box names, window names.
CAPS Keys on the keyboard and buttons on screens
and company name.
Constant width Text that you type, program code, files and
directory names, and function names.
[] Optional parameters.
{} Mandatory parameters.

Confidential and Proprietary Information of ZTE CORPORATION iii


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Typeface Meaning
| Select one of the parameters that are delimited
by it.
Note: Provides additional information about a
certain topic.
Checkpoint: Indicates that a particular step needs
to be checked before proceeding further.
Tip: Indicates a suggestion or hint to make things
easier or more productive for the reader.

Mouse TABLE 3 - MOUSE OPERATION CONVENTIONS


Operation
Conventions Typeface Meaning
Click Refers to clicking the primary mouse button (usually
the left mouse button) once.
Double-click Refers to quickly clicking the primary mouse button
(usually the left mouse button) twice.
Right-click Refers to clicking the secondary mouse button
(usually the right mouse button) once.
Drag Refers to pressing and holding a mouse button and
moving the mouse.

How to Get in Touch


The following sections provide information on how to obtain
support for the documentation and the software.
Customer If you have problems, questions, comments, or suggestions
Support regarding your product, contact us by e-mail at
support@zte.com.cn. You can also call our customer support
center at (86) 755 26771900 and (86) 800-9830-9830.
Documentation ZTE welcomes your comments and suggestions on the quality
Support and usefulness of this document. For further questions,
comments, or suggestions on the documentation, you can
contact us by e-mail at doc@zte.com.cn; or you can fax your
comments and suggestions to (86) 755 26772236. You can also
browse our website at http://support.zte.com.cn, which contains
various interesting subjects like documentation, knowledge base,
forum and service request.

iv Confidential and Proprietary Information of ZTE CORPORATION


Declaration of RoHS
Compliance

To minimize the environmental impact and take more


responsibility to the earth we live, this document shall serve as
formal declaration that the ZXG10 iBSC (V6.20.10) Base Station
Controller manufactured by ZTE CORPORATION is in compliance
with the Directive 2002/95/EC of the European Parliament -
RoHS (Restriction of Hazardous Substances) with respect to the
following substances:
„ Lead (Pb)
„ Mercury (Hg)
„ Cadmium (Cd)
„ Hexavalent Chromium (Cr (VI))
„ PolyBrominated Biphenyls (PBB’s)
„ PolyBrominated Diphenyl Ethers (PBDE’s)
The usage of the above substances in ZXG10 iBSC (V6.20.10) is
explained in the Table 4.

TABLE 4 – USAGE EXPLANATION OF THE HAZ ARDOUS SUBSTANCES IN ZXG10


IBSC (V6.20.10)

Hazardous substances
Names of Parts
Pb Hg Cd Cr(VI) PBB’s PBDE’s

System × 0 0 0 0 0
Cables and Assembly 0 0 0 0 0 0
Auxiliary Equipment × × × × × ×

Table Explanation:
0: The usage of the substance in all of the components is less
than the allowed values given by 2002/95/EC standard.
×: The usage of the substance in at least one of the components
is beyond the allowed values given by 2002/95/EC standard.

Confidential and Proprietary Information of ZTE CORPORATION v


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

The ZXG10 iBSC (V6.20.10) Base Station Controller


manufactured by ZTE CORPORATION meet the requirements of
EU 2002/95/EC; however, some assemblies are customized to
client specifications. Addition of specialized, customer-specified
materials or processes, which do not meet the requirements of
EU 2002/95 /EC, may negate RoHS compliance of the assembly.
To guarantee compliance of the assembly, the need for
compliant product must be communicated to ZTE CORPORATION
in written form.
This declaration is issued based on our current level of
knowledge. Since conditions of use are outside our control, ZTE
CORPORATION makes no warranties, express or implied, and
assumes no liability in connection with the use of this
information.

vi Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1

Sub Cell Statistics

Task of sub cell statistics is to measure channel and handover


status among sub cells, with focus on traffic sharing condition at
the second sub cell.
This chapter introduces the meaning, usage, and measurement
point of sub cell statistics counter.

Overview
Sub cell statistics counter is used to find out operation status of
the sub cell in radio environment. It focuses on inter-sub-cell
handover and relevant counting at the second sub cell so as to
check traffic absorption condition by the second sub cell.
The measurement takes sub cell as the statistics unit.

Sub Cell Statistics Counter Index


Table 5 lists counters related to sub cell statistics.

TABLE 5 - SUB CELL STATISTICS COUNTERS

Counter ID What It Counts


C901130001 Number of available TCH/Fs in the second sub cell
Number of unavailable TCH/Fs in the second sub
C901130002
cell
C901130003 Number of available TCH/Hs in the second sub cell
Number of unavailable TCH/Hs in the second sub
C901130004
cell
Number of handover attempts from the first sub
C901130005
cell to the second sub cell
Number of handover execution from the first sub
C901130006
cell to the second sub cell

Confidential and Proprietary Information of ZTE CORPORATION 7


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


Number of handover success from the first sub cell
C901130007
to the second sub cell
Number of handover attempts from the second sub
C901130008
cell to the first sub cell
Number of handover execution from the second
C901130009
sub cell to the first sub cell
Number of handover success from the second sub
C901130010
cell to the first sub cell
Number of handover attempts in the second sub
C901130011
cell
Number of handover execution in the second sub
C901130012
cell
C901130013 Number of handover success in the second sub cell
Number of outgoing inter-cell handover attempts of
C901130014
the second sub cell
Number of outgoing inter-cell handover execution
C901130015
of the second sub cell
Number of outgoing inter-cell handover success of
C901130016
the second sub cell
Handover attempts due to UL receiving strength of
C901130017
the full rate second sub cell
Handover attempts due to DL receiving strength of
C901130018
the full rate second sub cell
Handover attempts due to UL quality of the full rate
C901130019
second sub cell
Handover attempts due to DL quality of the full
C901130020
rate second sub cell
Handover attempts due to PBGT of the full rate
C901130021
second sub cell
Handover attempts due to traffic of the full rate
C901130022
second sub cell
Handover attempts due to UL interference of the
C901130023
full rate second sub cell (on TCH/F)
Handover attempts due to DL interference of the
C901130024
full rate second sub cell (on TCH/F)
Handover attempts due to good CI of the full rate
C901130025
second sub cell (on TCH/F)
Handover attempts due to bad CI of the full rate
C901130026
second sub cell (on TCH/F)
Handover attempts due to path loss and too large
C901130027
TA of the full rate second sub cell (on TCH/F)
Handover attempts due to path loss and too small
C901130028
TA of the full rate second sub cell (on TCH/F)
Number of forced transfer handover attempts of
C901130029
the full rate second sub cell (on TCH/F)

8 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

Counter ID What It Counts


Handover attempts due to other causes of the full
C901130030
rate second sub cell
Handover attempts due to UL receiving strength of
C901130031
the half rate second sub cell
Handover attempts due to DL receiving strength of
C901130032
the half rate second sub cell
Handover attempts due to UL quality of the half
C901130033
rate second sub cell
Handover attempts due to DL quality of the half
C901130034
rate second sub cell
Handover attempts due to PBGT of the half rate
C901130035
second sub cell
Handover attempts due to traffic of the half rate
C901130036
second sub cell
Handover attempts due to UL interference of the
C901130037
half rate second sub cell
Handover attempts due to DL interference of the
C901130038
half rate second sub cell
Handover attempts due to C/I of the half rate
C901130039
second sub cell
Handover attempts due to C/I of the half rate
C901130040
second sub cell
Handover attempts due to path loss and too large
C901130041
TA of the half rate second sub cell
Handover attempts due to path loss and too small
C901130042
TA of the half rate second sub cell
Number of forced transfer handover attempts of
C901130043
the half rate second sub cell
Handover attempts due to other causes of the half
C901130044
rate second sub cell
Number of attempts of TCH/F seizure of the second
C901130045
sub cell (used for assignment)
Number of TCH/F seizure success of the second sub
C901130046
cell (used for assignment)
Number of TCH/F seizure failure of the second sub
C901130047
cell (used for assignment)
Number of attempts of TCH/F seizure of the second
C901130048
sub cell (used for handover)
Number of TCH/F seizure success of the second sub
C901130049
cell (used for handover)
Number of TCH/F seizure failure of the second sub
C901130050
cell (used for handover)
Number of TCH/H seizure attempts of the second
C901130051
sub cell (used for assignment)
C901130052 Number of TCH/H seizure success of the second

Confidential and Proprietary Information of ZTE CORPORATION 9


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


sub cell (used for assignment)
Number of TCH/H seizure failure of the second sub
C901130053
cell (used for assignment)
Number of TCH/H seizure attempts of the second
C901130054
sub cell (used for handover)
Number of TCH/H seizure success of the second
C901130055
sub cell (used for handover)
Number of TCH/H seizure failure of the second sub
C901130056
cell (used for handover)
C901130057 Number of TCH/F call drops in the second sub cell
C901130058 Number of TCH/H call drops in the second sub cell
C901130059 TCH/F busy time in the second sub cell
C901130060 TCH/H busy time in the second sub cell

C901130001
Definition Number of available TCH/Fs in the second sub cell
Description This counter counts the number of available TCH/F channels in
the second sub cell.
Usage This counter is used to find out the number of available TCH/F
channels in the second sub cell, to learn the traffic of the second
sub cell.
Measurement Call database interface to count promptly.
Point

Unit Times

C901130002
Definition Number of unavailable TCH/Fs in the second sub cell
Description This counter counts the number of unavailable TCH/F channels
in the second sub cell.
Usage This counter is used to find out the number of available TCH/F
channels in the second sub cell, to learn the traffic of the second
sub cell.
Measurement Call database interface to count promptly.
Point

Unit Times

10 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

C901130003
Definition Number of available TCH/Hs in the second sub cell
Description This counter counts the number of available TCH/H channels in
the second sub cell.
Usage This counter is used to find out the number of available TCH/H
channels in the second sub cell, to learn the traffic of the second
sub cell.
Measurement Call database interface to count promptly.
Point

Unit Times

C901130004
Definition Number of unavailable TCH/Hs in the second sub cell
Description This counter counts the number of unavailable TCH/H channels
in the second sub cell.
Usage This counter is used to find out the number of available TCH/H
channels in the second sub cell, to learn the traffic of the second
sub cell.
Measurement Call database interface to count promptly.
Point

Unit Times

C901130005
Definition Number of handover attempts from the first sub cell to the
second sub cell
Description This counter counts the number of intra-cell handover attempts
from the first sub cell to the second sub cell.
Usage This counter is used to find out the frequency of intra-cell
handover attempts from the first sub cell to the second sub cell,
as one of the parameters to measure radio environment.
Measurement When BSC receives measurement reports from MS, it makes
Point handover decision. If it is decided to do intra-cell handover, and
current sub cell is the first sub cell, and if handover reason is
“too small Ta&PassLoss” or “too large C/I”, this counter
increments. The measurement point is A, as shown in Figure 1.

Confidential and Proprietary Information of ZTE CORPORATION 11


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 1 – INTRA-CELL HANDOVER ATTEMPT

Unit Times

C901130006
Definition Number of handover execution from the first sub cell to the
second sub cell
Description This counter counts the number of intra-cell handover execution
from the first sub cell to the second sub cell.
Usage This counter is used to find out the frequency of intra-cell
handover execution from the first sub cell to the second sub cell,
as one of the parameters to measure radio environment.
Measurement During inter-sub-cell handover within a cell, this counter
Point increments when following conditions are met:
The channel of target sub cell is successfully activated,
Current channel is in the second sub cell, and
Source channel is in the first sub cell.
The measurement point is A, as shown in Figure 2.

FIGURE 2 – INTRA-CELL INCOMING HANDOVER

Unit Times

C901130007
Definition Number of handover success from the first sub cell to the second
sub cell
Description This counter counts the number of intra-cell handover success
from the first sub cell to the second sub cell.

12 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

Usage This counter is used to find out the frequency of intra-cell


handover success from the first sub cell to the second sub cell,
as one of the parameters to measure radio environment.
Measurement During inter-sub-cell handover within a cell, target sub cell will
Point receive handover completion message, indicating that MS
successfully accesses to new channel. If target channel is in the
second sub cell, and source channel is in the first sub cell, this
counter increments. The measurement point is A, as shown in
Figure 3.

FIGURE 3 – SUCCESSFUL INTRA-CELL HANDOVER

BTS BSC

ASSIGN_ COM

Unit Times

C901130008
Definition Number of handover attempts from the second sub cell to the
first sub cell
Description This counter counts the number of intra-cell handover attempts
from the second sub cell to the first sub cell.
Usage This counter is used to find out the frequency of intra-cell
handover attempts from the second sub cell to the first sub cell,
as one of the parameters to measure radio environment.
Measurement When BSC receives measurement reports from MS, it makes
Point handover decision. If it is decided to do intra-cell handover, and
current sub cell is the second sub cell, and if handover reason is
“too small Ta&PassLoss” or “too large C/I”, this counter
increments. The measurement point is A, as shown in Figure 1.
Unit Times

C901130009
Definition Number of handover execution from the second sub cell to the
first sub cell
Description This counter counts the number of intra-cell handover execution
from the second sub cell to the first sub cell.
Usage This counter is used to find out the frequency of intra-cell
handover execution from the second sub cell to the first sub cell,
as one of the parameters to measure radio environment.

Confidential and Proprietary Information of ZTE CORPORATION 13


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Measurement During inter-sub-cell handover within a cell, this counter increments when
Point following conditions are met:
The channel of target sub cell is successfully activated,
Current channel is in the first sub cell, and
Source channel is in the second sub cell.
The measurement point is A, as shown in Figure 2.
Unit Times

C901130010
Definition Number of handover success from the second sub cell to the first
sub cell
Description This counter counts the number of intra-cell successful handover
from the second sub cell to the first sub cell.
Usage This counter is used to find out the frequency of intra-cell
handover ins success from the second sub cell to the first sub
cell, as one of the parameters to measure radio environment.
Measurement During inter-sub-cell handover within a cell, this counter
Point increments when following conditions are met:
Target sub cell receives handover completion message,
Target channel is in the first sub cell, and
Source channel is in the second sub cell.
The measurement point is A, as shown in Figure 3.
Unit Times

C901130011
Definition Number of handover attempts in the second sub cell
Description This counter counts the number of intra-cell handover attempts
within the second sub cell.
Usage This counter is used to find out the frequency of intra-cell
handover attempts within the second sub cell, as one of the
parameters to measure radio environment.
Measurement When BSC receives measurement reports from MS, it makes
Point handover decision. If it is decided to do intra-cell handover, and
current sub cell is the second sub cell, and if handover reason is
interference handover, this counter increments. The
measurement point is A, as shown in Figure 1.
Unit Times

14 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

C901130012
Definition Number of handover execution in the second sub cell
Description This counter counts the number of intra-cell handover execution
within the second sub cell.
Usage This counter is used to find out the frequency of intra-cell
handover execution within the second sub cell, as one of the
parameters to measure radio environment.
Measurement During inter-sub-cell handover within a cell, this counter
Point increments when following conditions are met:
The channel of target sub cell is successfully activated,
Current channel is in the first sub cell, and
Source channel is in the second sub cell.
The measurement point is A, as shown in Figure 2.
Unit Times

C901130013
Definition Number of handover success in the second sub cell
Description This counter counts the number of intra-cell handover ins
success within the second sub cell.
Usage This counter is used to find out the frequency of successful
handover from the second sub cell to the second sub cell, as one
of the parameters to measure radio environment.
Measurement During inter-sub-cell handover within a cell, this counter
Point increments when following conditions are met:
Target sub cell receives handover completion message,
Target channel is in the second sub cell, and
Source channel is in the first sub cells.
The measurement point is A, as shown in Figure 3.
Unit Times

C901130014
Definition Number of outgoing inter-cell handover attempts of the second
sub cell
Description This counter counts the number of inter-cell handover attempts
originated from the second sub cell.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 15


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This counter is used to find out the frequency of inter-cell


handover attempts originated from the second sub cell, as one
of the parameters to measure radio environment.
Measurement When BSC receives measurement reports from MS, it makes
Point handover decision. If it is decided to do inter-cell handover, and
source cell is the second sub cell, this counter increments. The
measurement point is A, as shown in Figure 1.
Unit Times

C901130015
Definition Number of outgoing inter-cell handover execution of the second
sub cell
Description This counter counts the number of inter-cell handover execution
originated from the second sub cell.
Usage This counter is used to find out the frequency of inter-cell
handover execution originated from the second sub cell, as one
of the parameters to measure radio environment.
Measurement During inter-cell handover, when source sub cell receives
Point available resource messages, and source sub cell is the second
sub cell, this counter increments. The measurement point is A,
as shown in Figure 4.

FIGURE 4 - INTER-CELL HANDOVER EXECUTION

BTS(Source) BSC BTS(Target)

CHANNEL ACTIVE ACK

HO_CMD A

Unit Times

C901130016
Definition Number of outgoing inter-cell handover success of the second
sub cell
Description This counter counts the Number of handover success inter-cell
originated from the second sub cell.
Usage This counter is used to find out the frequency of inter-cell
successful handover originated from the second sub cell, as one
of the parameters to measure radio environment.

16 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

Measurement During inter-sub-cell handover within a cell, source instance


Point receives the handover completion message returned from target
instance, indicating the MS has accessed to target channel. If
source sub cell is the second sub cell, this counter increments.
The measurement point is A, as shown in Figure 5.

FIGURE 5 – SUCCESSFUL INTRA-CELL HANDOVER

Unit Times

C901130017
Definition Handover attempts due to UL receiving strength of the full rate
second sub cell
Description This counter counts the number of handover attempts, caused
by too low UL receiving strength and originated from full rate
channel in the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by UL receiving strength and originated from
full rate channel in the second sub cell, as one of the references
for radio environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made,
„ Handover is caused by UL strength,
„ Source sub cell is the second sub cell, and
„ Current channel is full rate one.
The measurement point is A, as shown in Figure 6.

FIGURE 6 - HANDOVER DECISION

Confidential and Proprietary Information of ZTE CORPORATION 17


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Unit Times

C901130018
Definition Handover attempts due to DL receiving strength of the full rate
second sub cell
Description This counter counts the number of handover attempts, caused
by too low DL receiving strength and originated from full rate
channel in the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by DL receiving strength and originated from
full rate channel in the second sub cell, as one of the references
for radio environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by DL strength,
„ Source sub cell is the second sub cell, and
„ Current channel is full rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130019
Definition Handover attempts due to UL quality of the full rate second sub
cell
Description This counter counts the number of handover attempts, caused
by too poor UL quality and originated from full rate channel in
the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by UL quality and originated from full rate
channel in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made,
„ Handover is caused by UL quality,
„ Source sub cell is the second sub cell, and

18 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

„ Current channel is full rate one.


The measurement point is A, as shown in Figure 6.
Unit Times

C901130020
Definition Handover attempts due to DL quality of the full rate second sub
cell
Description This counter counts the number of handover attempts, caused
by too poor DL quality and originated from full rate channel in
the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by DL quality and originated from full rate
channel in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by DL quality,
„ Source sub cell is the second sub cell, and
„ Current channel is full rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130021
Definition Handover attempts due to PBGT of the full rate second sub cell
Description This counter counts the number of handover attempts, caused
by PBGT and originated from full rate channel in the second sub
cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by PBGT and originated from full rate channel
in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by PBGT,
„ Source sub cell is the second sub cell, and

Confidential and Proprietary Information of ZTE CORPORATION 19


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

„ Current channel is full rate one.


The measurement point is A, as shown in Figure 6.
Unit Times

C901130022
Definition Handover attempts due to traffic of the full rate second sub cell
Description This counter counts the number of handover attempts, caused
by traffic and originated from full rate channel in the second sub
cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by traffic and originated from full rate channel
in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by traffic,
„ Source sub cell is the second sub cell, and
„ Current channel is full rate one, this counter increments.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130023
Definition Handover attempts due to UL interference of the full rate second
sub cell (on TCH/F)
Description This counter counts the number of handover attempts, caused
by UL interference and originated from full rate channel in the
second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by UL interference and originated from full rate
channel in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by UL interference,
„ Source sub cell is the second sub cell, and

20 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

„ Current channel is full rate one.


The measurement point is A, as shown in Figure 6.
Unit Times

C901130024
Definition Handover attempts due to DL interference of the full rate second
sub cell (on TCH/F)
Description This counter counts the number of handover attempts, caused
by DL interference and originated from full rate channel in the
second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by DL interference and originated from full
rate channel in the second sub cell, as one of the references for
radio environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by DL interference,
„ Source sub cell is the second sub cell, and
„ Current channel is full rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130025
Definition Handover attempts due to good CI of the full rate second sub
cell (on TCH/F)
Description This counter counts the number of handover attempts, caused
by too good C/I and originated from full rate channel in the
second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by too good C/I and originated from full rate
channel in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:

Confidential and Proprietary Information of ZTE CORPORATION 21


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

„ Decision is made
„ Handover is caused by too good C/I,
„ Source sub cell is the second sub cell, and
„ Current channel is full rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130026
Definition Handover attempts due to bad CI of the full rate second sub cell
(on TCH/F)
Description This counter counts the number of handover attempts, caused
by too bad C/I and originated from full rate channel in the
second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by too bad C/I and originated from full rate
channel in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by too bad C/I,
„ Source sub cell is the second sub cell, and
„ Current channel is full rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130027
Definition Handover attempts due to path loss and too large TA of the full
rate second sub cell (on TCH/F)
Description This counter counts the number of handover attempts, caused
by too large path loss and TA and originated from full rate
channel in the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by too large path loss and TA and originated
from full rate channel in the second sub cell, as one of the
references for radio environment in the second sub cell.

22 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

Measurement Make handover decision after BSC receives measurement


Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by too large path loss and TA,
„ Source sub cell is the second sub cell, and
„ Current channel is full rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130028
Definition Handover attempts due to path loss and too small TA of the full
rate second sub cell (on TCH/F)
Description This counter counts the number of handover attempts, caused
by too small path loss and TA and originated from full rate
channel in the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by too small path loss and TA and originated
from full rate channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by too small path loss and TA,
„ Source sub cell is the second sub cell, and
„ Current channel is full rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130029
Definition Number of forced transfer handover attempts of the full rate
second sub cell (on TCH/F)
Description This counter counts the number of handover attempts, caused
by forced transfer handover and originated from full rate channel
in the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by forced transfer handover and originated

Confidential and Proprietary Information of ZTE CORPORATION 23


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

from full rate channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by forced transfer,
„ Source sub cell is the second sub cell, and
„ Current channel is full rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130030
Definition Handover attempts due to other causes of the full rate second
sub cell
Description This counter counts the number of handover attempts, caused
by other causes and originated from full rate channel in the
second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by other causes and originated from full rate
channel in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by other reasons,
„ Source sub cell is the second sub cell, and
„ Current channel is full rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130031
Definition Handover attempts due to UL receiving strength of the half rate
second sub cell
Description This counter counts the number of handover attempts, caused
by too low UL receiving strength and originated from half rate
channel in the second sub cell.
Usage

24 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

This counter is used to find out the frequency of handover


attempts, caused by UL receiving strength and originated from
half rate channel in the second sub cell, as one of the references
for radio environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by UL strength,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130032
Definition Handover attempts due to DL receiving strength of the half rate
second sub cell
Description This counter counts the number of handover attempts, caused
by too low DL receiving strength and originated from half rate
channel in the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by DL receiving strength and originated from
half rate channel in the second sub cell, as one of the references
for radio environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by DL strength,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130033
Definition Handover attempts due to UL quality of the half rate second sub
cell
Description

Confidential and Proprietary Information of ZTE CORPORATION 25


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This counter counts the number of handover attempts, caused


by too poor UL quality and originated from half full rate channel
in the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by UL quality and originated from half rate
channel in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by UL quality,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130034
Definition Handover attempts due to DL quality of the half rate second sub
cell
Description This counter counts the number of handover attempts, caused
by too poor DL quality and originated from half rate channel in
the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by DL quality and originated from full rate
channel in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by DL quality,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130035
Definition Handover attempts due to PBGT of the half rate second sub cell

26 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

Description This counter counts the number of handover attempts, caused


by PBGT and originated from half rate channel in the second sub
cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by PBGT and originated from half rate channel
in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by PBGT,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130036
Definition Handover attempts due to traffic of the half rate second sub cell
Description This counter counts the number of handover attempts, caused
by traffic and originated from half rate channel in the second sub
cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by traffic and originated from half rate channel
in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by traffic,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130037
Definition Handover attempts due to UL interference of the half rate
second sub cell (on TCH/F)

Confidential and Proprietary Information of ZTE CORPORATION 27


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Description This counter counts the number of handover attempts, caused


by UL interference and originated from half rate channel in the
second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by UL interference and originated from half
rate channel in the second sub cell, as one of the references for
radio environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by UL interference,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130038
Definition Handover attempts due to DL interference of the half rate
second sub cell (on TCH/F)
Description This counter counts the number of handover attempts, caused
by DL interference and originated from half rate channel in the
second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by DL interference and originated from half
rate channel in the second sub cell, as one of the references for
radio environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by DL interference,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130039
Definition

28 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

Handover attempts due to CI of the half rate second sub cell (on
TCH/F)
Description This counter counts the number of handover attempts, caused
by too good C/I and originated from half rate channel in the
second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by too good C/I and originated from half rate
channel in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by too good C/I,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130040
Definition Handover attempts due to CI of the half rate second sub cell (on
TCH/F)
Description This counter counts the number of handover attempts, caused
by too bad C/I and originated from half rate channel in the
second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by too bad C/I and originated from half rate
channel in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by too bad C/I,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 29


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901130041
Definition Handover attempts due to path loss and too large TA of the half
rate second sub cell (on TCH/F)
Description This counter counts the number of handover attempts, caused
by too large path loss and TA and originated from half rate
channel in the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by too large path loss and TA and originated
from half rate channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by too large path loss and TA,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130042
Definition Handover attempts due to path loss and too small TA of the half
rate second sub cell (on TCH/F)
Description This counter counts the number of handover attempts, caused
by too small path loss and TA and originated from half rate
channel in the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by too small path loss and TA and originated
from half rate channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by too small path loss and TA,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

30 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

C901130043
Definition Number of forced transfer handover attempts of the half rate
second sub cell (on TCH/F)
Description This counter counts the number of handover attempts, caused
by forced transfer handover and originated from half rate
channel in the second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by forced transfer handover and originated
from half rate channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by forced transfer,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

C901130044
Definition Handover attempts due to other causes of the half rate second
sub cell
Description This counter counts the number of handover attempts, caused
by other causes and originated from half rate channel in the
second sub cell.
Usage This counter is used to find out the frequency of handover
attempts, caused by other causes and originated from half rate
channel in the second sub cell, as one of the references for radio
environment in the second sub cell.
Measurement Make handover decision after BSC receives measurement
Point reports. This counter increments when following conditions are
met:
„ Decision is made
„ Handover is caused by other reasons,
„ Source sub cell is the second sub cell, and
„ Current channel is half rate one.
The measurement point is A, as shown in Figure 6.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 31


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901130045
Definition Number of attempts of TCH/F seizure of the second sub cell
(used for assignment)
Description This counter counts the number of seizure attempts in TCH/F
channel in the second sub cell.
Usage This counter is used to find out the frequency of seizure
attempts in TCH/F channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement Measurement points of this counter include two types.
Point
„ When successfully applying for channel, if channel type is
TCH/F, and application reason is assignment, this counter
increments. Successful application includes:
f Successful resource application;
f Resource acquisition by queuing, seizure, or dynamic channel
conversion.
„ When channel application is failed, if channel type is TCH/F,
and application reason is assignment, this counter
increments. Failure reasons of application channel include:
f Receive release command while waiting for resource state;
f Failed to configure instance number while seizing channel;
f Timeout while queuing or seizure, or waiting for resource
timer;
f No available radio resource.
Unit Times

C901130046
Definition Number of TCH/F seizure success of the second sub cell (used
for assignment)
Description This counter counts the number of successful seizure in TCH/F
channel in the second sub cell.
Usage This counter is used to find out the frequency of successful
seizure in TCH/F channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement This counter increments when following conditions are met:
Point
„ Successfully applying for channel
„ Channel type is TCH/F
„ Application reason is assignment

32 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

Successful application includes: successful resource application;


resource acquisition by queuing, seizure, or dynamic channel
conversion.
Unit Times

C901130047
Definition Number of TCH/F seizure failure of the second sub cell (used for
assignment)
Description This counter counts the number of seizure failure in TCH/F
channel in the second sub cell.
Usage This counter is used to find out the frequency of seizure failure
in TCH/F channel in the second sub cell, as one of the references
for radio environment in the second sub cell.
Measurement When channel application is failed, if channel type is TCH/F, and
Point application reason is assignment, this counter increments.
Failure reasons of application channel include:
„ Receive release command while waiting for resource state;
„ Failed to configure instance number while seizing channel;
„ Timeout while queuing or seizure, or waiting for resource
timer;
„ No available radio resource.
Unit Times

C901130048
Definition Number of attempts of TCH/F seizure of the second sub cell
(used for handover)
Description This counter counts the number of seizure attempts in TCH/F
channel in the second sub cell.
Usage This counter is used to find out the frequency of seizure
attempts in TCH/F channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement Measurement points of this counter include two types.
Point
When channel is successfully applied, if channel type is TCH/F,
and application reason is handover, this counter increments.
Successful application includes: successful resource application;
resource acquisition by queuing, seizure, or dynamic channel
conversion.
When channel application is failed, if channel type is TCH/F, and
application reason is handover, this counter increments. Failure
reasons of application channel include:

Confidential and Proprietary Information of ZTE CORPORATION 33


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

„ Receive release command while waiting for resource state;


„ Failed to configure instance number while seizing channel;
„ Timeout while queuing or seizure, or waiting for resource
timer;
„ No available radio resource.
Unit Times

C901130049
Definition Number of TCH/F seizure success of the second sub cell (used
for handover)
Description This counter counts the number of successful seizure in TCH/F
channel in the second sub cell.
Usage This counter is used to find out the frequency of successful
seizure in TCH/F channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement This counter increments when following conditions are met:
Point
„ Channel is successfully applied,
„ Channel type is TCH/F, and
„ Application reason is handover.
Successful application includes: successful resource application;
resource acquisition by queuing, seizure, or dynamic channel
conversion.
Unit Times

C901130050
Definition Number of TCH/F seizure failure of the second sub cell (used for
handover)
Description This counter counts the number of seizure failure in TCH/F
channel in the second sub cell.
Usage This counter is used to find out the frequency of seizure failure
in TCH/F channel in the second sub cell, as one of the references
for radio environment in the second sub cell.
Measurement When channel application is failed, if channel type is TCH/F, and
Point application reason is handover, this counter increments. Failure
reasons of application channel include:
„ Receive release command while waiting for resource state;
„ Failed to configure instance number while seizing channel;
„ Timeout while queuing or seizure, or waiting for resource
timer;

34 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

„ No available radio resource.


Unit Times

C901130051
Definition Number of TCH/H seizure attempts of the second sub cell (used
for assignment)
Description This counter counts the number of seizure attempts in TCH/H
channel in the second sub cell.
Usage This counter is used to find out the frequency of seizure
attempts in TCH/H channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement Measurement points of this counter include two types.
Point
„ When channel is successfully applied, if channel type is
TCH/H, and application reason is assignment, this counter
increments. Successful application includes: successful
resource application; resource acquisition by queuing,
seizure, or dynamic channel conversion.
„ When channel application is failed, if channel type is TCH/H,
and application reason is assignment, this counter
increments. Failure reasons of application channel include:
f Receive release command while waiting for resource state;
f Failed to configure instance number while seizing channel;
f Timeout while queuing or seizure, or waiting for resource
timer;
f No available radio resource.
Unit Times

C901130052
Definition Number of TCH/H seizure success of the second sub cell (used
for assignment)
Description This counter counts the number of successful seizure in TCH/H
channel in the second sub cell.
Usage This counter is used to find out the frequency of successful
seizure in TCH/H channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement When successfully applying for channel, if channel type is TCH/H,
Point and application reason is assignment, this counter increments.
Successful application includes: successful resource application;
resource acquisition by queuing, seizure, or dynamic channel
conversion.

Confidential and Proprietary Information of ZTE CORPORATION 35


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Unit Times

C901130053
Definition Number of TCH/H seizure failure of the second sub cell (used for
assignment)
Description This counter counts the number of seizure failure in TCH/H
channel in the second sub cell.
Usage This counter is used to find out the frequency of seizure failure
in TCH/H channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement When channel application is failed, if channel type is TCH/H, and
Point application reason is assignment, this counter increments.
Failure reasons of application channel include:
„ Receive release command while waiting for resource state;
„ Failed to configure instance number while seizing channel;
„ Timeout while queuing or seizure, or waiting for resource
timer;
„ No available radio resource.
Unit Times

C901130054
Definition Number of TCH/H seizure attempts of the second sub cell (used
for handover)
Description This counter counts the number of seizure attempts in TCH/H
channel in the second sub cell.
Usage This counter is used to find out the frequency of seizure
attempts in TCH/H channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement Measurement points of this counter include two types.
Point
„ When channel is successfully applied, if channel type is
TCH/H, and application reason is handover, this counter
increments. Successful application includes: successful
resource application; resource acquisition by queuing,
seizure, or dynamic channel conversion.
„ When channel application is failed, if channel type is TCH/H,
and application reason is handover, this counter increments.
Failure reasons of application channel include:
f Receive release command while waiting for resource state;
f Failed to configure instance number while seizing channel;

36 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

f Timeout while queuing or seizure, or waiting for resource


timer;
f No available radio resource.
Unit Times

C901130055
Definition Number of TCH/H seizure success of the second sub cell (used
for handover)
Description This counter counts the number of successful seizure in TCH/H
channel in the second sub cell.
Usage This counter is used to find out the frequency of successful
seizure in TCH/H channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement When channel is successfully applied, if channel type is TCH/H,
Point and application reason is handover, this counter increments.
Successful application includes: successful resource application;
resource acquisition by queuing, seizure, or dynamic channel
conversion.
Unit Times

C901130056
Definition Number of TCH/H seizure failure of the second sub cell (used for
handover)
Description This counter counts the number of seizure failure in TCH/H
channel in the second sub cell.
Usage This counter is used to find out the frequency of seizure failure
in TCH/H channel in the second sub cell, as one of the
references for radio environment in the second sub cell.
Measurement When channel application is failed, if channel type is TCH/H and
Point application reason is handover, this counter increments. Failure
reasons of application channel include:
„ Receive release command while waiting for resource state;
„ Failed to configure instance number while seizing channel;
„ Timeout while queuing or seizure, or waiting for resource
timer;
„ No available radio resource.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 37


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901130057
Definition Number of TCH/F call drops in the second sub cell
Description This counter counts the number of call drops in TCH/F channel in
the second sub cell.
Usage This counter is used to find out the frequency of call drops in
TCH/F channel in the second sub cell, as one of the references
for radio environment in the second sub cell.
Measurement During call drops, if current channel is TCH/F, this counter
Point increments. Call drops include following cases:
„ After handover and deliver assignment command in cell, call
drops occur due to 3107 timer timeout;
„ After inter-cell handover delivers handover command, call
drops occur due to 3103 timer timeout;
„ After handover and deliver external handover command, call
drops occur due to outgoing protection timer timeout; and
„ BSC receives radio link failure message.
Unit Times

C901130058
Definition Number of TCH/H call drops in the second sub cell
Description This counter counts the number of call drops in TCH/H channel
in the second sub cell.
Usage This counter is used to find out the frequency of call drops in
TCH/H channel in the second sub cell, as one of the references
for radio environment in the second sub cell.
Measurement During call drops, if current channel is TCH/H, this counter
Point increments. Call drops include following cases:
„ After handover and deliver assignment command in cell, call
drops occur due to 3107 timer timeout;
„ After inter-cell handover delivers handover command, call
drops occur due to 3103 timer timeout;
„ After handover and deliver external handover command, call
drops occur due to outgoing protection timer timeout;
„ BSC receives radio link failure message.
Unit Times

38 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Sub Cell Statistics

C901130059
Definition TCH/F busy time in the second sub cell
Description This counter counts the seizure time in TCH/F channel in the
second sub cell.
Usage This counter is used to find out the seizure time in TCH/F
channel in the second sub cell, as one of the references for
traffic condition in the second sub cell.
Measurement This counter will count at following two cases:
Point
„ When seize or release TCH/F channel within a cell. Seizure
channel means successful application of radio resource for
database. Channel release means two cases: instance
release caused by different reasons and release while waiting
resource timer timeout.
„ When promptly report measurement data.
Unit Second

C901130060
Definition TCH/H busy time in the second sub cell
Description This counter counts the seizure time in TCH/H channel in the
second sub cell.
Usage This counter is used to find out the seizure time in TCH/H
channel in the second sub cell, as one of the references for
traffic condition in the second sub cell.
Measurement This counter will count at following two cases:
Point
„ When seize or release TCH/F channel within a cell. Seizure
channel means successful application of radio resource for
database. Channel release means two cases: instance
release caused by different reasons and release while waiting
resource timer timeout.
„ When promptly report measurement data.
Unit Second

Confidential and Proprietary Information of ZTE CORPORATION 39


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This page is intentionally blank.

40 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2

MS TA Measurement
This chapter contains detailed information about counters
related to MS TA measurement.

Overview
MS TA counters are used to check the value of TA in MS
measurement reports. TA can reflect the relative location of MS
in the cell. If most of the TAs are in very high level, network
planning should be remade, such as, increasing the site density.
The measurement takes cell as the statistics unit.

MS TA Measurement Counter Index


Table 6 lists counters related to MS TA measurement.

TABLE 6 - MS TA MEASUREMENT COUNTERS

Count ID What It Counts


C901140001 Number of TA=0
C901140002 Number of 0<TA<=2
C901140003 Number of 2<TA<=4
C901140004 Number of 4<TA<=6
C901140005 Number of 6<TA<=8
C901140006 Number of 8<TA<=10
C901140007 Number of 10<TA<=12
C901140008 Number of 12<TA<=14
C901140009 Number of 14<TA<=16
C901140010 Number of 16<TA<=18
C901140011 Number of 18<TA<=20
C901140012 Number of 20<TA<=22
C901060013 Number of 22<TA<=24

Confidential and Proprietary Information of ZTE CORPORATION 41


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Count ID What It Counts


C901140014 Number of 24<TA<=26
C901140015 Number of 26<TA<=28
C901140016 Number of 28<TA<=30
C901140017 Number of 30<TA<=32
C901140018 Number of 32<TA<=34
C901140019 Number of 34<TA<=36
C901140020 Number of 36<TA<=38
C901140021 Number of 38<TA<=40
C901140022 Number of 40<TA<=42
C901140023 Number of 42<TA<=44
C901140024 Number of 44<TA<=46
C901140025 Number of 46<TA<=48
C901140026 Number of 48<TA<=50
C901140027 Number of 50<TA<=52
C901140028 Number of 52<TA<=54
C901140029 Number of 54<TA<=56
C901140030 Number of 56<TA<=58
C901140031 Number of 58<TA<=60
C901140032 Number of 60<TA<=63
C901140033 Number of TA>63

C901140001
Definition Number of TA=0.
Description This counter counts the number of times of TA=0 in the MS
measurement reports.
Usage This counter is used to find out the frequency of TA=0 in the MS
measurement reports. It can be one of the parameters that are
used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with TA=0. The measurement point is A, as
shown in Figure 7.

42 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - MS TA Measurement

FIGURE 7 – MS MEASUREMENT REPORT

MS BTS BSC

MEAS REP
MEAS RES

Unit Times

C901140002
Definition Number of 0<TA<=2.
Description This counter counts the number of times of 0<TA<=2 in the MS
measurement reports.
Usage This counter is used to find out the frequency of 0<TA<=2 in the
MS measurement reports. It can be one of the parameters that
are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 0<TA<=2. The measurement point is
A, as shown in Figure 7.
Unit Times

C901140003
Definition Number of 2<TA<=4.
Description This counter counts the number of times of 2<TA<=4 in the MS
measurement reports.
Usage This counter is used to find out the frequency of 2<TA<=4 in the
MS measurement reports. It can be one of the parameters that
are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 2<TA<=4. The measurement point is
A, as shown in Figure 7.
Unit Times

C901140004
Definition Number of 4<TA<=6.
Description

Confidential and Proprietary Information of ZTE CORPORATION 43


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This counter counts the number of times of 4<TA<=6 in the MS


measurement reports.
Usage This counter is used to find out the frequency of 4<TA<=6 in the
MS measurement reports. It can be one of the parameters that
are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 4<TA<=6. The measurement point is
A, as shown in Figure 7.
Unit Times

C901140005
Definition Number of 6<TA<=8.
Description This counter counts the number of times of 6<TA<=8 in the MS
measurement reports.
Usage This counter is used to find out the frequency of 6<TA<=8 in the
MS measurement reports. It can be one of the parameters that
are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 6<TA<=8. The measurement point is
A, as shown in Figure 7.
Unit Times

C901140006
Definition Number of 8<TA<=10.
Description This counter counts the number of times of 8<TA<=10 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 8<TA<=10 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 8<TA<=10. The measurement point is
A, as shown in Figure 7.
Unit Times

C901140007
Definition Number of 10<TA<=12.
Description This counter counts the number of times of 10<TA<=12 in the
MS measurement reports.

44 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - MS TA Measurement

Usage This counter is used to find out the frequency of 10<TA<=12 in


the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 10<TA<=12. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140008
Definition Number of 12<TA<=14.
Description This counter counts the number of times of 12<TA<=14 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 12<TA<=14 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 12<TA<=14. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140009
Definition Number of 14<TA<=16.
Description This counter counts the number of times of 14<TA<=16 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 14<TA<=16 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 14<TA<=16. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140010
Definition Number of 16<TA<=18.
Description This counter counts the number of times of 16<TA<=18 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 16<TA<=18 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.

Confidential and Proprietary Information of ZTE CORPORATION 45


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Measurement This counter increments when BSC receives the MS


Point measurement report with 16<TA<=18. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140011
Definition Number of 18<TA<=20.
Description This counter counts the number of times of 18<TA<=20 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 18<TA<=20 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 18<TA<=20. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140012
Definition Number of 20<TA<=22.
Description This counter counts the number of times of 20<TA<=22 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 20<TA<=22 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 20<TA<=22. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140013
Definition Number of 22<TA<=24.
Description This counter counts the number of times of 22<TA<=24 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 22<TA<=24 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 22<TA<=24. The measurement point
is A, as shown in Figure 7.

46 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - MS TA Measurement

Unit Times

C901140014
Definition Number of 24<TA<=26.
Description This counter counts the number of times of 24<TA<=26 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 24<TA<=26 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 24<TA<=26. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140015
Definition Number of 26<TA<=28.
Description This counter counts the number of times of 26<TA<=28 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 26<TA<=28 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 26<TA<=28. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140016
Definition Number of 28<TA<=30.
Description This counter counts the number of times of 28<TA<=30 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 28<TA<=30 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 28<TA<=30. The measurement point
is A, as shown in Figure 7.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 47


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901140017
Definition Number of 30<TA<=32.
Description This counter counts the number of times of 30<TA<=32 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 30<TA<=32 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 30<TA<=32. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140018
Definition Number of 32<TA<=34.
Description This counter counts the number of times of 32<TA<=34 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 32<TA<=34 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 32<TA<=34. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140019
Definition Number of 34<TA<=36.
Description This counter counts the number of times of 34<TA<=36 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 34<TA<=36 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 34<TA<=36. The measurement point
is A, as shown in Figure 7.
Unit Times

48 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - MS TA Measurement

C901140020
Definition Number of 36<TA<=38.
Description This counter counts the number of times of 36<TA<=38 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 36<TA<=38 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 36<TA<=38. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140021
Definition Number of 38<TA<=40.
Description This counter counts the number of times of 38<TA<=40 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 38<TA<=40 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 38<TA<=40. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140022
Definition Number of 40<TA<=42.
Description This counter counts the number of times of 40<TA<=42 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 40<TA<=42 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 40<TA<=42. The measurement point
is A, as shown in Figure 7.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 49


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901140023
Definition Number of 42<TA<=44.
Description This counter counts the number of times of 42<TA<=44 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 42<TA<=44 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 42<TA<=44. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140024
Definition Number of 44<TA<=46.
Description This counter counts the number of times of 44<TA<=46 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 44<TA<=46 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 44<TA<=46. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140025
Definition Number of 46<TA<=48.
Description This counter counts the number of times of 46<TA<=48 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 46<TA<=48 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 46<TA<=48. The measurement point
is A, as shown in Figure 7.
Unit Times

50 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - MS TA Measurement

C901140026
Definition Number of 48<TA<=50.
Description This counter counts the number of times of 48<TA<=50 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 48<TA<=50 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 48<TA<=50. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140027
Definition Number of 50<TA<=52.
Description This counter counts the number of times of 50<TA<=52 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 50<TA<=52 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 50<TA<=52. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140028
Definition Number of 52<TA<=54.
Description This counter counts the number of times of 52<TA<=54 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 52<TA<=54 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 52<TA<=54. The measurement point
is A, as shown in Figure 7.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 51


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901140029
Definition Number of 54<TA<=56.
Description This counter counts the number of times of 54<TA<=56 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 54<TA<=56 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 54<TA<=56. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140030
Definition Number of 56<TA<=58.
Description This counter counts the number of times of 56<TA<=58 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 56<TA<=58 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 56<TA<=58. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140031
Definition Number of 58<TA<=60.
Description This counter counts the number of times of 58<TA<=60 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 58<TA<=60 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 58<TA<=60. The measurement point
is A, as shown in Figure 7.
Unit Times

52 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - MS TA Measurement

C901140032
Definition Number of 60<TA<=63.
Description This counter counts the number of times of 60<TA<=63 in the
MS measurement reports.
Usage This counter is used to find out the frequency of 60<TA<=63 in
the MS measurement reports. It can be one of the parameters
that are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with 60<TA<=63. The measurement point
is A, as shown in Figure 7.
Unit Times

C901140033
Definition Number of TA>63.
Description This counter counts the number of times of TA>63 in the MS
measurement reports.
Usage This counter is used to find out the frequency of TA>63 in the
MS measurement reports. It can be one of the parameters that
are used to evaluate the cell radio environment.
Measurement This counter increments when BSC receives the MS
Point measurement report with TA>63. The measurement point is A,
as shown in Figure 7.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 53


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This page is intentionally blank.

54 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3

SAPI3 Measurement
This chapter contains detailed information about counters
related to SAPI3 measurement.

Overview
MO-SM is short message of mobile originating call; MT-SM is
short messages of mobile terminating call. In conversation
status, the MS can receive point-to-point message so the mobile
caller maybe the other side of receiving short message at one
time. On the wireless side, short message could be transmitted
by the following five channels: SACCH/F, SACCH/H, SDCCH,
FACCHF and FACCHH. So far the statistics counting has been
realized by the channel of SACCH/F, SACCH/H and SDCCH.
The measurement takes cell as the statistics unit.

SAPI3 Measurement Counter Index


Table 7 lists counters related to SAPI3 measurement.

TABLE 7 - S API3 MEASUREMENT COUNTERS

Count ID What It Counts


Number of SAPI3 link establishments on SACCH/F
C901150001
(MO-SM)
Number of SAPI3 link establishments on SACCH/H
C901150002
(MO-SM)
Number of SAPI3 link establishments on FACCH/F
C901150004
(MO-SM)
Number of SAPI3 link establishments on FACCH/H
C901150005
(MO-SM)
Number of SAPI3 link establishment requests on
C901150006
SACCH/F (MT-SM)
Number of SAPI3 link establishment requests on
C901150007
SACCH/H (MT-SM)

Confidential and Proprietary Information of ZTE CORPORATION 55


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Count ID What It Counts


Number of SAPI3 link establishment requests on
C901150009
FACCH/F (MT-SM)
Number of SAPI3 link establishment requests on
C901150010
FACCH/H (MT-SM)
Number of successful SAPI3 link establishments on
C901150011
SACCH/F (MT-SM)
Number of successful SAPI3 link establishments on
C901150012
SACCH/H (MT-SM)
Number of successful SAPI3 link establishments on
C901150014
FACCH/F (MT-SM)
Number of successful SAPI3 link establishments on
C901150015
FACCH/H (MT-SM)
Number of DTAP messages used as SDCCH UL
C901150016
point-to-point short messages (SMs)
Number of DTAP messages used as SDCCH DL
C901150017
point-to-point short messages (SMs)
Number of DTAP messages on FACCH/F UL for
C901150018
point-to-point short messages
Number of DTAP messages on FACCH/F DL for
C901150019
point-to-point short messages
Number of DTAP messages on FACCH/H UL for
C901150020
point-to-point short messages
Number of DTAP messages on FACCH/H DL for
C901150021
point-to-point short messages
Number of DTAP messages on SACCH/F DL for
C901150022
point-to-point short messages
Number of DTAP messages on SACCH/F DL for
C901150023
point-to-point short messages
Number of DTAP messages on SACCH/H UL for
C901150024
point-to-point short messages
Number of DTAP messages on SACCH/H DL for
C901150025
point-to-point short messages

C901150001
Definition Number of SAPI3 link establishments on SACCH/F (MO-SM)
Description This counter counts the number of short message link
establishment of mobile originating call via SACCH/F. On
SDCCH/F, BSC receives EST_IND message sent by BTS. If the
layer 3 information in this message is SAPI=3, the counter
increments.
Usage This counter is used to find out the frequency of SAPI3 link
establishments on SACCH/F.

56 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - SAPI3 Measurement

Measurement This counter counts the number of BSC receiving EST_IND


Point message sent by BTS with SAPI=3. The measurement point is A,
as shown in Figure 8.

FIGURE 8 - FLOW OF MO SHORT MESSAGES DURING CONVERSATION

MS BTS BSC MSC

Active Call

CM Ser Req

CM Ser Accept

SABM( SAPI=3)
Est Ind (SAPI=3)
UA
A1
CP_DATA(RP_ DATA)
To SC
A2
CP_ ACK
A3
From SC
CP_DATA(RP_ ACK)
A4
CP_ ACK

A5

Active Call

Unit Times

C901150002
Definition Number of SAPI3 link establishments on SACCH/H (MO-SM)
Description This counter counts the number of short message link
establishment of mobile originating call via SACCH/H. On
SDCCH/H, BSC receives EST_IND message sent by BTS. If the
layer 3 information in this message is SAPI=3, the counter
increments.
Usage This counter is used to find out the frequency of SAPI3 link
establishments on SACCH/H.
Measurement This counter counts the number of BSC receiving EST_IND
Point message with SAPI=3. The measurement point is A1, as shown
in Figure 8.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 57


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901150004
Definition Number of SAPI3 link establishments on FACCH/F (MO-SM)
Description This counter counts the number of short message link
establishment of mobile originating call via FACCH/F. On
FACCH/F, BSC receives EST_IND message sent by BTS. If the
layer 3 information in this message is SAPI=3, the counter
increments.
Usage This counter is used to find out the frequency of SAPI3 link
establishments on FACCH/F.
Measurement This counter is not realized at present in the system.
Point

Unit Times

C901150005
Definition Number of SAPI3 link establishments on FACCH/H (MO-SM)
Description This counter counts the number of short message link
establishment of mobile originating call via FACCH/H. On
FACCH/H, BSC receives EST_IND message sent by BTS. If the
layer 3 information in this message is SAPI=3, the counter
increments.
Usage This counter is used to find out the frequency of SAPI3 link
establishments on FACCH/H.
Measurement This counter is not realized at present in the system.
Point

Unit Times

C901150006
Definition Number of SAPI3 link establishment requests on SACCH/F (MT-
SM)
Description This counter counts the number of short message link
establishment of mobile originating call via SACCH/F. On
SACCH/F, if BSC receives DTAP_IND message sent by MSC with
SAPI=3 while the short message link between BSC and MS is not
established, BSC initiates link establishment flow and the
counter increments.
Usage This counter is used to find out the frequency of SAPI3 link
establishment requests on SACCH/F.
Measurement This counter counts the number of BSC sending EST_REQ
Point message to BTS with SAPI=3 while the short message link

58 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - SAPI3 Measurement

between BSC and MS is not established. The measurement point


is C1, as shown in Figure 9.

FIGURE 9 - FLOW OF MT SHORT MESSAGE DURING CONVERSATION

Unit Times

C901150007
Definition Number of SAPI3 link establishment requests on SACCH/H (MT-
SM)
Description This counter counts the number of short message link establishment of
mobile terminating call via SACCH/H. On SACCH/H, if BSC receives
DTAP_IND message sent by MSC with SAPI=3 while the short
message link between BSC and MS is not established, BSC initiates
link establishment flow and the counter increments.
Usage This counter is used to find out the frequency of SAPI3 link
establishment requests on SACCH/H.
Measurement This counter counts the number of BSC sending EST_REQ
Point message to BTS with SAPI=3 while the short message link
between BSC and MS is not established. The measurement point
is C1, as shown in Figure 9.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 59


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901150009
Definition Number of SAPI3 link establishment requests on FACCH/F (MT-
SM)
Description This counter counts the number of short message link
establishment of mobile terminating call via FACCH/F. On
FACCH/F, if BSC receives DTAP_IND message sent by MSC with
SAPI=3 while the short message link between BSC and MS is not
established, BSC initiates link establishment flow and the
counter increments.
Usage This counter is used to find out the frequency of SAPI3 link
establishment requests on FACCH/F.
Measurement This counter is not realized at present in the system.
Point

Unit Times

C901150010
Definition Number of SAPI3 link establishment requests on FACCH/H (MT-
SM)
Description This counter counts the number of short message link
establishment of mobile terminating call via FACCH/H. On
FACCH/H, if BSC receives DTAP_IND message sent by MSC with
SAPI=3 while the short message link between BSC and MS is not
established, BSC initiates link establishment flow and the
counter increments.
Usage This counter is used to find out the frequency of SAPI 3 link
establishment requests on FACCH/H.
Measurement This counter is not realized at present in the system.
Point

Unit Times

C901150011
Definition Number of successful SAPI3 link establishments on SACCH/F
(MT-SM)
Description This counter counts the number of successful short message link
establishment of mobile terminating call via SACCH/F. On
SACCH/F, if BSC receives EST_CONF message sent by BTS after
it initiates short message link establishment flow, this link
establishment succeeds, and the counter increments.

60 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - SAPI3 Measurement

Usage This counter is used to find out the frequency of successful


SAPI3 link establishments on SACCH/F.
Measurement This counter counts the number of BSC receiving EST_IND
Point message send by BTS with SAPI=3. The measurement point is
C2, as shown in Figure 9.
Unit Times

C901150012
Definition Number of successful SAPI3 link establishments on SACCH/H
(MT-SM)
Description This counter counts the number of successful short message link
establishment of mobile terminating call via SACCH/H. On
SACCH/H, if BSC receives EST_CONF message sent by BTS after
it initiates short message link establishment flow, this link
establishment succeeds, and the counter increments.
Usage This counter is used to find out the frequency of successful
SAPI3 link establishments on SACCH/H.
Measurement This counter counts the number of BSC receiving EST_CONF
Point message send by BTS with SAPI=3. The measurement point is
C2, as shown in Figure 9.
Unit Times

C901150014
Definition Number of successful SAPI3 link establishments on FACCH/F
(MT-SM)
Description This counter counts the number of successful short message link
establishment of mobile terminating call via FACCH/F. On
FACCH/F, if BSC receives EST_CONF message sent by BTS after
it initiates short message link establishment flow, this link
establishment succeeds, and the counter increments.
Usage This counter is used to find out the frequency of successful
SAPI3 link establishments on SACCH/F.
Measurement This counter is not realized at present in the system.
Point

Unit Times

C901150015
Definition Number of successful SAPI3 link establishments on FACCH/H
(MT-SM)

Confidential and Proprietary Information of ZTE CORPORATION 61


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Description This counter counts the number of successful short message link
establishment of mobile terminating call via FACCH/H. On
FACCH/H, if BSC receives EST_CONF message sent by BTS after
it initiates short message link establishment flow, this link
establishment succeeds, and the counter increments.
Usage This counter is used to find out the frequency of successful
SAPI3 link establishments on FACCH/H.
Measurement This counter is not realized at present in the system.
Point

Unit Times

C901150016
Definition Number of DTAP messages used as SDCCH UL point-to-point
short messages (SMs)
Description This counter counts the number of DTAP packet sent by MS to
the network side via SDCCH.
Usage This counter is used to find out the frequency of DTAP message
of point-to-point message on SDCCH UL.
Measurement This counter counts the number of BSC receiving DTAP packet
Point sent by BTS on SDCCH with SAPI=3. The measurement points
are D4 and D5 as shown in Figure 10, and B2 and B5 as shown in
Figure 11.

62 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - SAPI3 Measurement

FIGURE 10 - FLOW OF MT SHORT MESSAGE IN IDLE STATUS

Confidential and Proprietary Information of ZTE CORPORATION 63


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 11 - FLOW OF MO SHORT MESSAGE IN IDLE STATUS

Unit Times

C901150017
Definition Number of DTAP messages used as SDCCH DL point-to-point
short messages (SMs)
Description This counter counts the number of DTAP packet of short
message sent by network side to MS via SDCCH.
Usage This counter is used to find out the frequency of DTAP message
of point-to-point short messages on SDCCH DL.
Measurement This counter counts the number of BSC sending DTAP packet to
Point BTS on SDCCH with SAPI=3. The measurement points are D3
and D6 as shown in Figure 10, and B3 and B4 as shown in Figure
11.
Unit Times

64 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - SAPI3 Measurement

C901150018
Definition Number of DTAP messages on FACCH/F UL for point-to-point
short messages
Description This counter counts the number of DTAP packet sent by MS to
network side via FACCH/F.
Usage This counter is used to find out the frequency of DTAP message
of point-to-point short messages on FACCH/F UL.
Measurement This counter is not realized at present in the system.
Point

Unit Times

C901150019
Definition Number of DTAP messages on FACCH/F DL for point-to-point
short messages
Description This counter counts the number of DTAP packet of short
messages sent by network side to MS via FACCH/F.
Usage This counter is used to find out the frequency of DTAP message
of point-to-point short messages on FACCH/F DL.
Measurement This counter is not realized at present in the system.
Point

Unit Times

C901150020
Definition Number of DTAP messages on FACCH/H UL for point-to-point
short messages
Description This counter counts the number of DTAP packet of short
messages sent by MS to network side via FACCH/H.
Usage This counter is used to find out the frequency of DTAP message
of point-to-point short messages on FACCH/H UL.
Measurement This counter is not realized at present in the system.
Point

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 65


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901150021
Definition Number of DTAP messages on FACCH/H DL for point-to-point
short messages
Description This counter counts the number of DTAP packet of short
messages sent by network side to MS via FACCH/H.
Usage This counter is used to find out the frequency of DTAP message
of point-to-point short messages on FACCH/H DL.
Measurement This counter is not realized at present in the system.
Point

Unit Times

C901150022
Definition Number of DTAP messages on SACCH/F UL for point-to-point
short messages
Description This counter counts the number of DTAP packet of short
messages sent by MS to network side via SACCH/F.
Usage This counter is used to find out the frequency of point-to-point
DTAP message of point-to-point short messages on SACCH/F UL.
Measurement This counter counts the number of BSC receiving DTAP packet
Point sent by BTS on SDCCH with SAPI=3. The measurement points
are C4 and C5 as shown in Figure 9, and A2 and A5 as shown in
Figure 8.
Unit Times

C901150023
Definition Number of DTAP messages on SACCH/F DL for point-to-point
short messages
Description This counter counts the number of DTAP packet of short
messages sent by network side to MS via SACCH/F.
Usage This counter is used to find out the frequency of DTAP message
of point-to-point short messages on SACCH/F DL.
Measurement This counter counts the number of BSC sending DTAP packet to
Point BTS on SACCH/F with SAPI=3. The measurement points are C3
and C6 as shown in Figure 9, and A3 and A4, as shown in Figure 8.
Unit Times

66 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - SAPI3 Measurement

C901150024
Definition Number of DTAP messages on SACCH/H UL for point-to-point
short messages
Description This counter counts the number of DTAP packet sent by MS to
network side via SACCH/H.
Usage This counter is used to find out the frequency of DTAP message
of point-to-point short messages on SACCH/H UL.
Measurement This counter counts the number of BSC receiving DTAP packet
Point sent by BTS on SDCCH with SAPI=3. The measurement points
are C4 and C5 as shown in Figure 9, and A2 and A5 as shown in
Figure 8.
Unit Times

C901150025
Definition Number of DTAP messages on SACCH/H DL for point-to-point
short messages
Description This counter counts the number of DTAP packet of short
messages sent by network side to MS via SACCH/H.
Usage This counter is used to find out the frequency of DTAP message
of point-to-point short messages on SACCH/H UL.
Measurement This counter counts the number of BSC sending DTAP packet to
Point BTS on SACCH/H with SAPI=3. The measurement points are C3
and C6 as shown in Figure 9, and A3 and A4 as shown in Figure
8.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 67


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This page is intentionally blank.

68 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4

Uplink and Downlink


PACCH Statistics

This chapter contains detailed information about counters


related to UL and DL PACCH statistics.

Overview
In transmitting GPRS data service, UL and DL PACCH statistics is
used to count the number of receiving and sending controlled
messages on PACCH, including packet access reject, packet
resource request, packet UL assignment, etc.
The measurement takes cell as the statistics unit.

UL and DL PACCH Statistics


Counter Index
Table 8 lists counters related to UL and DL PACCH statistics.

TABLE 8 - UL AND DL P ACCH STATISTICS COUNTERS

Counter ID What It Counts


C901160001 Number of Packet access reject message
C901160002 Number of Packet resource request message
C901160003 Number of Packet UL Assignment message
Number of Additional MS access capabilities
C901160004
message
C901160005 Number of Packet DL Assignment message
C901160006 Number of Packet TBF release message
C901160007 Number of Packet DL Ack/Nack message

Confidential and Proprietary Information of ZTE CORPORATION 69


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


C901160008 Number of EGPRS Packet DL Ack/Nack message
C901160009 Number of Packet UL Ack/Nack message
Number of Packet Control Acknowledgement
C901160010
message
C901160011 Number of Packet Cell Change Continue message
C901160012 Number of Packet Cell Change Failure message
C901160013 Number of Packet Cell Change Notification message
C901160014 Number of Packet Cell Change Order message
C901160017 Number of packet mobile TBF status messages
C901160018 Number of packet neighbor cell data messages
C901160019 Number of packet PDCH release messages
C901160020 Number of packet polling request messages
Number of packet power control/timing advance
C901160021
messages
C901160022 Number of packet PSI status message
C901160023 Number of packet serving cell data messages
C901160024 Number of packet SI status messages
C901160025 Number of packet timeslot reconfigure messages
C901160026 Number of packet paging request message
C901160027 Number of PSI message

C901160001
Definition Number of packet access reject messages
Description When MS sends packet resource request to BSC via BTS, BSC
will return packet UL assignment to MS or packet access reject
on PACCH.
This counter counts the number of BSC sending the packet
access reject messages on PACCH.
Usage This counter is used to check the packet access reject messages
sent by BSC in packet transmission mode.
Measurement When the UPPB of BSC sends packet access reject messages to
Point MS, the counter increments. The measurement point is A2, as
shown in Figure 12.

70 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Uplink and Downlink PACCH Statistics

FIGURE 12 – MEASUREMENT POINT OF PACKET RESOURCE REQUEST AND


P ACKET ACCESS REJECT

Unit Times

C901160002
Definition Number of packet resource request messages
Description When TBF has established the need to redistribute resource, TBF
access by double steps or TBF release to re-establish, MS start
the packet resource request messages on PACCH to BSC via BTS.
This counter counts the number of BSC receiving the packet
resource request messages on PACCH in packet transmission
mode.
Measurement When the UPPB of BSC receives packet resource request
Point messages, the counter increments. The measurement point is
A1, as shown in Figure 12.
Unit Times

C901160003
Definition Number of packet UL assignment messages
Description Packet UL assignment can be sent on both PCCCH and PACCH.
When established for TBF double steps, the first packet UL
assignment needs to be sent on PCCH, other packet UL
assignments such as DL TBF or resource redistribution initiated
by MS will be sent on PACCH by BSC.
This counter counts the number of packet UL assignment
messages sent by BSC on PACCH.
Measurement When the type of DL control block sent by BSC is packet UL
Point assignment, the counter increments. The measurement point is
A, as shown in Figure 13.

Confidential and Proprietary Information of ZTE CORPORATION 71


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 13 – MEASUREMENT POINT OF PACKET UL ASSIGNMENT MESSAGE

Unit Times

C901160004
Definition Number of additional MS access capabilities messages
Description This counter counts the number of additional MS access
capabilities messages received by BSC on PACCH in packet
transmission mode.
Measurement When the type of UL control block received by BSC is additional
Point MS access capabilities, the counter increments. The
measurement point is A, as shown in Figure 14.

FIGURE 14 – MEASUREMENT POINT OF ADDITIONAL MS ACCESS


CAP ABILITIES MESSAGE

Unit Times

72 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Uplink and Downlink PACCH Statistics

C901160005
Definition Number of packet DL assignment messages
Description This counter counts the number of packet DL assignment
messages sent by BSC on PACCH in packet transmission mode.
Measurement When the type of DL control block sent by BSC is packet DL
Point assignment, the counter increments. The measurement point is
A, as shown in Figure 15.

F I G U R E 1 5 – D L S E N T O N P AC C H I N P A C K E T T R A N S M I S S I O N M O D E

Unit Times

C901160006
Definition Number of packet TBF release messages
Description This counter counts the number of packet TBF release messages
on PACCH sent by BSC.
Measurement When the type of DL control block sent by BSC is packet TBF
Point release, the counter increments. The measurement point is A, as
shown in Figure 16.

Confidential and Proprietary Information of ZTE CORPORATION 73


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 16 - DL SENT ON PACCH IN P ACKET TRANSMISSION MODE

Unit Times

C901160007
Definition Number of packet DL Ack/Nack messages
Description After TBF is established and DL RLC set RRBP on sending data
block, MS sends packet DL Ack/Nack messages on PACCH.
This counter counts the number of packet DL Ack/Nack
messages received by BSC on PACCH in packet transmission
mode.
Measurement When the type of UL control block sent by BSC is packet DL
Point Ack/Nack, the counter increments. The measurement points are
A, A1, as shown in Figure 16.
Unit Times

C901160008
Definition Number of EGPRS Packet DL Ack/Nack messages
Description After TBF is established and DL RLC set RRBP on sending data
block, MS sends packet DL Ack/Nack messages on PACCH.
This counter counts the number of EGPRS packet DL Ack/Nack
messages received by BSC on PACCH in EGPRS packet
transmission mode.
Measurement
Point

74 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Uplink and Downlink PACCH Statistics

When the type of UL control block sent by BSC is EGPRS packet


DL Ack/Nack, the counter increments. The measurement points
are A and A1, as shown in Figure 16.
Unit Times

C901160009
Definition Number of Packet UL Ack/Nack messages
Description This counter counts the number of packet UL Ack/Nack
messages sent by BSC on PACCH in packet transmission mode.
Measurement When the type of DL control block sent by BSC is packet UL
Point Ack/Nack, the counter increments. The measurement point is A,
as shown in Figure 17.

FIGURE 17 - SIGNALING TR ANSMISSION ON P ACCH

Unit Times

C901160010
Definition Number of packet control acknowledgement messages
Description This counter counts the number of packet control
acknowledgement messages received by BSC on PACCH in
packet transmission mode.
Measurement When the type of UL control block received by BSC is packet
Point control acknowledgement, the counter increments. The
measurement point is B, as shown in Figure 17.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 75


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901160011
Definition Number of packet cell change continue messages
Description After BSC receives packet cell change messages, it will send
“packet cell change continues” messages to MS on PACCH or
packet cell changes command to inform MS to switch to the new
cell.
This counter counts the number of “packet cell change
continues” messages sent by BSC on PACCH.
Measurement BSC initiates timer after receiving PACKET NEIGHBOR CELL
Point CHANGE NOTIFICATION. If it receives the packet system
message of destination cell in the defined time, BSC send PACK
NEIGHBOR CELL DATA, then send PACKET CELL CHANGE
CONTINUES, the counter increments. The measurement point is
A3, as shown in Figure 18.

FIGURE 18 – ME ASUREM ENT POI NT OF P ACKET-CELL-CH ANGE-RELATED


COUNTER (1)

MS BSC

PACKET NEIGHBOUR CELL


CHANGE NOTIFICATION

A1
PACKET NEIGHBOUR CELL DATA
A2
PACKET CELL CHANGE CONTINUE

A3

BSC initiates timer after receiving the PACKET NEIGHBOR CELL


CHANGE NOTIFICATION message. If timer times out and doesn’t
receive the packet system message of destination cell, BSC
sends the PACK CELL CHANGE CONTINUE message directly, the
counter increments. The measurement point is A1, as shown in
Figure 19.

76 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Uplink and Downlink PACCH Statistics

FIGURE 19 – ME ASUREM ENT POI NT OF P ACKET-CELL-CH ANGE-RELATED


COUNTER (2)

Unit Times

C901160012
Definition Number of packet cell change failure messages
Description After BSC sends packet cell change command to MS, BTS
initiates packet cell change failure to BSC to indicate that the cell
fails to change command.
This counter counts the number of packet cell change failure
messages received by BSC on PACCH in packet transmission
mode.
Measurement When the type of UL control block sent by BSC is packet cell
Point change failure, the counter increments. The measurement point
is A3, as shown in Figure 20.
Unit Times

C901160013
Definition Number of packet cell change notification messages
Description If MS intends to handoff from service cell to destination cell, it
will initiate packet cell change notification to BSC to request the
system message of destination under the condition that the
network and MS support NACC.
This counter counts the number of packet cell change
notification messages received by BSC on PACCH in packet
transmission mode.
Measurement When the type of UL control block received by BSC is packet cell
Point change notification, the counter increments. The measurement
point is A1, as shown in Figure 18.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 77


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901160014
Definition Number of packet cell change order messages
Description When the MS initiates the packet cell change notification, this
counter counts the number of packet cell change order
messages sent by BSC on PACCH in packet transmission mode.
Measurement When BSC sends packet cell change order messages, the
Point counter increments. The measurement point is A2, as shown in
Figure 20.

FIGURE 20 – MEASUREMENT POINT OF PACKET CELL CHANGE ORDER AND


P ACKET CELL CHANGE FAILURE

MS BSC

PACKET NEIGHBOUR CELL


CHANGE NOTIFICATION

A1
PACKET CELL CHANGE ORDER

A2
PACKET CELL CHANGE FAIL

A3

Unit Times

C901160017
Definition Number of packet mobile TBF status messages
Description This counter counts the number of packet mobile TBF status
messages sent by BSC on PACCH in packet service.
Measurement When the type of UL control block received by BSC is packet
Point mobile TBF, the counter increments. The measurement point is
A, as shown in Figure 21.

78 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Uplink and Downlink PACCH Statistics

FIGURE 21 – MEASUREMENT POINT OF PACKET MOBILE STATUS MESSAGE ON


P AC C H

Unit Times

C901160018
Definition Number of packet neighbor cell data messages
Description If MS sends change notification to neighboring cell in support of
NACC, BSC will send packet neighboring cell data to MS via BTS.
This counter counts the number of packet neighboring cell data
sent by BSC on PACCH in packet transmission mode.
Measurement When the type of DL control block sent by BSC is packet
Point neighboring cell data, the counter increments. The measurement
point is A2, as shown in Figure 18.
Unit Times

C901160019
Definition Number of packet PDCH release messages
Description This counter counts the number of packet PDCH release
messages sent by BSC on PACCH.
Measurement When the type of DL control block sent by BSC is packet PDCH
Point release, the counter increments.
Unit Times

C901160020
Definition Number of packet polling request messages
Description This counter counts the number of packet polling request
messages sent by BSC on PACCH in packet transmission mode.

Confidential and Proprietary Information of ZTE CORPORATION 79


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Measurement When the type of DL control block sent by BSC is packet polling
Point request, the counter increments. The measurement point is A,
as shown in Figure 22.

FIGURE 22 – MEASUREMENT POINT OF DL TBF ESTABLISHES EXECUTION


POLLING

Unit Times

C901160021
Definition Number of packet power control/timing advance messages
Description This counter counts the number of packet power control/timing
advance messages sent by BSC on PACCH.
Measurement When the type of DL control block sent by BSC is packet power
Point control/timing advance message, the counter increments. The
measurement point is A, as shown in Figure 23.

FIGURE 23 – MEASUREMENT POINT OF PACKET POWER CONTROL/TIMING


ADV ANCE MESSAGE SENT ON P ACCH

80 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Uplink and Downlink PACCH Statistics

Unit Times

C901160022
Definition Number of packet PSI status messages
Description In order to obtain the packet system messages of serving cell,
MS initiates packet PSI status messages to BSC via BTS to
indicate that MS has been received the packet system messages.
This counter counts the number of packet PSI status messages
received by BSC on PACCH.
Measurement When the type of UL control block sent by BSC is packet PSI
Point Status message, the counter increments. The measurement
point is A1, as shown in Figure 24.

FIGURE 24 – MEASUREMENT POINT OF PACKET-SERVICE-CELL-DATA-


RELATED COUNTER

MS BSC

PACKET PSI/SI Status

A1
PACKET SERVING CELL DATA

A2

Unit Times

C901160023
Definition Number of packet serving cell data messages
Description Network uses packet serving cell data to send the system
messages and packet messages of serving cell to MS, this
counter counts the number of packet serving cell data messages
received by BSC on PACCH.
Usage This counter is used to check packet serving cell data messages
sent by BSC on PACCH.
Measurement When the type of DL control block sent by BSC is packet serving
Point cell data messages, the counter increments. The measurement
point is A2, as shown in Figure 24.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 81


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901160024
Definition Number of packet SI status messages
Description In order to obtain the system messages of serving cell, MS
initiates packet SI status message to BSC via BTS to indicate
that MS has received the packet system messages.
This counter counts the number of packet SI status messages
received by BSC on PACCH.
Measurement When the type of UL control block sent by BSC is packet SI
Point status messages, the counter increments. The measurement
point is A1, as shown in Figure 24.
Unit Times

C901160025
Definition Number of packet timeslot reconfigure messages
Description Packet timeslot reconfigure is used to assign UL and DL resource
link.
This counter counts the number of packet timeslot reconfigure
messages sent by BSC on PACCH.
Measurement When the type of DL control block sent by BSC is packet timeslot
Point reconfigure messages, the counter increments. The
measurement point is A, as shown in Figure 25 and Figure 26.

FIGURE 25 – FLOW OF ESTABLISHING UL ON P ACCH UNDER DL


TRANSMISSION STATUS

82 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Uplink and Downlink PACCH Statistics

FIGURE 26 – FLOW OF ESTABLISHING DL ON P ACCH UNDER UL


TRANSMISSION STATUS

Unit Times

C901160026
Definition Number of packet paging request message
Description If MS is in packet transmission status or attached by GPRS, BSC
will send packet paging request messages.
This counter counts the number of packet paging request messages sent
by BSC on PACCH.
Measurement When the type of DL control block sent by BSC to MS via BTS is
Point packet paging request messages, the counter increments. The
measurement point is A, as shown in Figure 27.

FIGURE 27 – MEASUREMENT POINT OF BSC ISSUING PACKET P AGING


REQUEST MESSAGE

MS BSS

P_PAGING_REQ

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 83


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901160027
Definition Number of PSI message
Description This counter counts the number of PSI messages sent by BSC on
PACCH in packet service.
Measurement When the type of DL control block sent by BSC to MS via BTS is
Point packet system message, the counter increments. The
measurement point is A, as shown in Figure 28.

FIGURE 28 – MEASUREMENT POINT OF BSC ISSUING PACKET SYSTEM


MESSAGE

MS BSS
P_PSYS_INFO1 or
P_PSYS_INFO13

Unit Times

84 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5

Downlink GPRS Data TBF


Statistics

DL (DL) GPRS data TBF statistics aims to measure the process of


cell-level GPRS DL TBF establishment and release.
This chapter describes the definition, usage and measurement
point of various counters.

Overview
DL GPRS data TBF statistics is used to observe the process of
GPRS DL TBF establishment, maintenance and release.
The measurement takes cell as the statistics unit.

DL GPRS Data TBF Statistics


Counter Index
Table 9 lists counters related to DL GPRS data TBF statistic.
TA B L E 9 - DL G P R S D AT A T B F S TAT I S T I C S C O U N T E R S

Counter ID What It Counts


Number of GPRS DL TBF establishment requests on
C901170002
CCCH/PCCCH
Number of GPRS DL TBF establishment requests on
C901170003
PACCH
Number of GPRS DL TBF establishment failure due
C901170004
to CPU
Number of GPRS DL TBF establishment failure due
C901170005
to not support DTM
Number of GPRS DL TBF establishment failure due
C901170007
to Abis congestion

Confidential and Proprietary Information of ZTE CORPORATION 85


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


Number of GPRS DL TBF establishment failure due
C901170008
to RR congestion
Number of GPRS DL TBF establishment failure due
C901170009
to UPPB-DSP channel congestion
Number of GPRS DL TBF establishment channel
C901170010
allocate success
Number of allocated PDCH for GPRS DL TBF
C901170011
establishment
Number of GPRS DL TBF establishment failure due
C901170012
to channel activate failed
Number of GPRS DL TBF establishment failure due
C901170013
to BTS connection failed
Number of GPRS DL TBF establishment failure due
C901170014
to BIU connection failed
Number of GPRS DL TBF channel activate
C901170015
establishment success
Number of GPRS DL TBF establishment failure on
C901170016
CCCH/PCCCH due to not receive PIA
Number of GPRS DL TBF establishment failure on
C901170017
CCCH/PCCCH due to UPPB-DSP congestion
Number of GPRS DL TBF establishment failure on
C901170018
PACCH due to UPPB-DSP congestion
Number of GPRS DL TBF establishment success on
C901170019
PCCCH/CCCH
Number of GPRS DL TBF establishment success on
C901170020
PACCH
Number of GPRS DL TBF resource reallocation
C901170023 failure due to Abis congestion for UL TBF
establishment
Number of GPRS DL TBF resource reallocation
C901170024 failure due to RR congestion for UL TBF
establishment
Number of GPRS DL TBF resource reallocation
C901170025 failure due to UPPB-DSP channel congestion for UL
TBF establishment
Number of GPRS DL TBF resource reallocation
C901170026
success due to UL TBF establishment
Number of allocated PDCH for GPRS DL TBF
C901170027
resource reallocation due to UL TBF establishment
Number of GPRS DL TBF resource reallocation
C901170028 failure due to channel activate failure for UL TBF
establishment
Number of GPRS DL TBF resource reallocation
C901170029 failure due to BTS connection failure for UL TBF
establishment
C901170030 Number of GPRS DL TBF resource reallocation

86 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

Counter ID What It Counts


failure due to BIU connection failure for UL TBF
establishment
Number of GPRS DL TBF resource reallocation
C901170031 success of channel activate for UL TBF
establishment
Number of GPRS DL TBF resource reallocation
C901170032
failure due to UL TBF establishment
Number of GPRS DL TBF resource reallocation
C901170033
success due to UL TBF establishment
Number of GPRS DL TBF resource reallocation
C901170036
failure due to Abis congestion for LLC transmission
Number of GPRS DL TBF resource reallocation
C901170037
failure due to RR congestion for LLC transmission
Number of GPRS DL TBF resource reallocation
C901170038 failure due to UPPB-DSP channel congestion for LLC
transmission
Number of GPRS DL TBF resource reallocation
C901170039
success due to LLC transmission
Number of allocated PDCH for GPRS DL TBF
C901170040
resource reallocation due to LLC transmission
Number of GPRS DL TBF resource reallocation
C901170041 failure due to channel activate failure for LLC
transmission
Number of GPRS DL TBF resource reallocation
C901170042 failure due to BTS connection failure for LLC
transmission
Number of GPRS DL TBF resource reallocation
C901170043 failure due to BIU connection failure for LLC
transmission
Number of GPRS DL TBF resource reallocation
C901170044
success of channel activate for LLC transmission
Number of GPRS DL TBF resource reallocation
C901170045
failure due to LLC transmission
Number of GPRS DL TBF resource reallocation
C901170046
success due to LLC transmission
C901170047 Number of GPRS DL TBF release due to flush LL
Number of GPRS DL TBF release due to GPRS
C901170048
suspend requests
C901170049 Number of GPRS DL TBF forcing release by CS
Number of GPRS DL TBF normal release due to
C901170050
user plane requests
Number of GPRS DL TBF abnormal release due to
C901170051
user plane requests
Number of GPRS DL TBF release due to NSVC
C901170052
unavailability
C901170053 Number of GPRS DL TBF release due to BVC

Confidential and Proprietary Information of ZTE CORPORATION 87


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


unavailability
Number of GPRS DL TBF release due to other
C901170054
reasons
C901170055 Number of DL GPRS TBF grab resources
C901170056 Number of grab instance by DL GPRS TBF
C901170057 Number of DL GPRS TBF queuing
C901170058 Number of DL GPRS TBF queuing success
Number of DL GPRS TBF release TBF during
C901170059
queuing

C901170002
Definition Number of GPRS DL TBF establishment requests on
CCCH/PCCCH
Description This counter counts the number of DL establishment requests
received by control plane when BSC initially attempts to
establish GPRS DL TBF.
Usage This counter is used to find out the frequency of DL
establishment requests sent from CCCH/PCCCH and received by
control plane when BSC establishes GPRS DL TBF.
Measurement When RANPS module receives the DL request
Point (EV_RANUMC_DLASS_REQ) sent from RANUMC module, the
counter increments. The measurement point is A, as shown in
Figure 29.

FIGURE 29 – DL REQUEST

PS用户面 PS控制面

下行请求消息

Unit Times

C901170003
Definition Number of GPRS DL TBF establishment requests on PACCH
Description This counter counts the number of establishing GPRS DL TBF on
PACCH by MS.
Usage This counter is used to find out the frequency of establishing DL
TBF in PACCH after MS has established GPRS UL TBF.

88 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

Measurement After MS has established GPRS UL TBF, RANPS module receives


Point EV_MAC_DL_ASSIGN_REQ message sent from RANU module,
the counter increments. The measurement point is A, as shown
in Figure 30.

FIGURE 30 – DL ASSIGNMENT REQUEST

PS用户面 PS控制面

下行指派消息

Unit Times

C901170004
Definition Number of GPRS DL TBF establishment failure due to CPU
Description No statistics temporarily.

C901170005
Definition Number of GPRS DL TBF establishment failure due to not
support DTM
Description No statistics temporarily.

C901170007
Definition Number of GPRS DL TBF establishment failure due to Abis
congestion
Description This counter counts the number of failures that RANPS applies to
database for resource and the cause of failures is Abis
congestion when BSC attempts to establish GPRS DL TBF.
Usage This counter is used to find out the frequency of failures that
RANPS applies to database for resource and the cause of failures
is Abis congestion when BSC attempts to establish GPRS DL TBF.
Measurement The measurement is taken at two time points listed below:
Point
„ After RANPS module receives DL request message
(EV_RANUMC_DLASS_REQ) sent from RANUMC module, if
resource application fails and the cause of failure is Abis
congestion, the counter increments. The measurement point
is A, as shown in Figure 31.

Confidential and Proprietary Information of ZTE CORPORATION 89


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 31 – DAT AB ASE AP PLICATION F AILURE DUE TO ABIS CONGESTION I

PS用户面 PS控制面 数据库

下行请求消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

„ After MS establishes GPRS UL TBF, RANPS module receives


EV_MAC_DL_ASSIGN_REQ message sent from RANU module,
if resource application fails and the cause of failure is Abis
congestion, the counter increments. The measurement point
is A, as shown in Figure 32.

FIGURE 32 – DAT AB ASE AP PLICATION F AILURE DUE TO ABIS CONGESTION II

PS用户面 PS控制面 数据库

下行请求消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

Unit Times

C901170008
Definition Number of GPRS DL TBF establishment failure due to RR
congestion
Description This counter counts the number of failures that RANPS applies to
database for resource and the cause of failures is RR congestion
when BSC attempts to establish GPRS DL TBF. There are three
causes for RR congestion: MS per channel (number of MS
reaches the peak in each channel), TAI/TFI (no TAI or TFI) and
no PDCH (no PS channel).
Usage This counter is used to find out the frequency of failures that
RANPS applies to database for resource and the cause of failures
is RR congestion when BSC attempts to establish GPRS DL TBF.
Measurement The measurement is taken at two time points listed below:
Point
„ After RANPS module receives DL request message
(EV_RANUMC_DLASS_REQ) sent from RANUMC module, if

90 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

resource application fails and the cause of failure is RR


congestion, the counter increments. The measurement point
is A, as shown in Figure 33.

FIGURE 33 – DAT AB ASE AP PLICATION F AILURE DUE TO RR CONGESTION I

PS用户面 PS控制面 数据库

下行请求消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

„ After MS establishes GPRS UL TBF, RANPS module receives


EV_MAC_DL_ASSIGN_REQ message sent from RANU module,
if resource application fails and the cause of failure is RR
congestion, the counter increments. The measurement point
is A, as shown in Figure 34.

FIGURE 34 – DAT AB ASE AP PLICATION F AILURE DUE TO RR CONGESTION II

PS用户面 PS控制面 数据库

下行请求消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

Unit Times

C901170009
Definition Number of GPRS DL TBF establishment failure due to UPPB-DSP
channel congestion
Description This counter counts the number of failures that RANPS applies to
database for resource and the cause of failures is UPPB-DSP
channel congestion when BSC attempts to establish GPRS DL
TBF.
Usage This counter is used to find out the frequency of failures that
RANPS applies to database for resource and the cause of failures
is UPPB-DSP channel congestion when BSC attempts to establish
GPRS DL TBF.

Confidential and Proprietary Information of ZTE CORPORATION 91


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Measurement The measurement is taken at two time points listed below:


Point
„ After RANPS module receives DL request message
(EV_RANUMC_DLASS_REQ) sent from RANUMC module, if
resource application fails and the cause of failure is UPPB-
DSP channel congestion, the counter increments. The
measurement point is A, as shown in Figure 35.

FIGURE 35 – DAT AB ASE AP PLICATION F AILURE DUE TO UPPB-DSP CHANNEL


CONGESTION I

PS用户面 PS控制面 数据库

下行请求消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

„ After MS establishes GPRS UL TBF, RANPS module receives


EV_MAC_DL_ASSIGN_REQ message sent from RANU module,
if resource application fails and the cause of failure is UPPB-
DSP channel congestion, the counter increments. The
measurement point is A, as shown in Figure 36.

FIGURE 36 – DAT AB ASE AP PLICATION F AILURE DUE TO UPPB-DSP CHANNEL


CONGESTION II

PS用户面 PS控制面 数据库

下行请求消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

Unit Times

C901170010
Definition Number of GPRS DL TBF establishment channel allocate success
Description This counter counts the number of channel allocate success
applied by RANPS when BSC attempts to establish GPRS DL TBF.
Usage This counter is used to find out the frequency of successful
resource application that RANPS sends when BSC attempts to
establish GPRS DL TBF.

92 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

Measurement After RANPS module receives DL request message


Point (EV_RANUMC_DLASS_REQ) sent from RANUMC module, when
resource application succeeds, the counter increments. The
measurement point is A, as shown in Figure 37.

FIGURE 37 – SUCCESSFUL RESOURCE APPLICATION

PS用户面 PS控制面 数据库

下行请求消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

Unit Times

C901170011
Definition Number of allocated PDCH for GPRS DL TBF establishment
Description This counter counts the number of successful allocated PDCH
when BSC attempts to establish GPRS DL TBF.
Usage This counter is used to find out the number of successful
allocated PDCH when BSC attempts to establish GPRS DL TBF.
Measurement After RANPS module receives DL request message
Point (EV_RANUMC_DLASS_REQ) sent from RANUMC module, when
resource application succeeds, the counter accumulates the
PDCH number. The measurement point is A, as shown in Figure
37.
Unit Times

C901170012
Definition Number of GPRS DL TBF establishment failure due to channel
activate failed
Description This counter counts the number of PDCH activate failure when
BSC establishes GPRS DL TBF.
Usage This counter is used to find out the frequency of PDCH activate
failure when BSC establishes GPRS DL TBF (including
establishing DL TBF initially and establishing DL TBF while UL
TBF already exists).
Measurement The measurement is taken at two time points listed below:
Point

Confidential and Proprietary Information of ZTE CORPORATION 93


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

„ When BSC receives PDCH activation failure message reported


by BTS, the counter increments. The measurement point is A,
as shown in Figure 38.

FIGURE 38 – PDCH ACTIVATION FAILURE

„ If “wait for PDCH activate & connection response” timer


expires, and BSC has not received PDCH activate response
message reported by BTS, the counter increments.
Unit Times

C901170013
Definition Number of GPRS DL TBF establishment failure due to BTS
connection failed
Description This counter counts the number of connection failure due to BTS
connection failed when BSC establishes GPRS DL TBF.
Usage This counter is used to find out the frequency of connection
failure due to BTS connection failed when BSC establishes GPRS
DL TBF (including establishing DL TBF initially and establishing
DL TBF while UL TBF already exists).
Measurement The measurement is taken at two time points listed below:
Point
„ If RANPS module receives connection failed message
reported by connection module, and the cause of failure is
BTS connection failed, the counter increments. The
measurement point is A, as shown in Figure 39.

FIGURE 39 – CONNECTION FAILURE DUE TO BTS CONNECTION FAILED

BTS BSC
PACKET CHANNEL ACTIVE
NACK CHANNEL
PACKET (due to BTSACTIVE
connection
NACK
(原因为BTS失败)
failed)
A

„ If “wait for PDCH activate & connection response” timer


expires, and BSC has not received connection success
response message reported by connection module, the
counter increments.

94 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

Unit Times

C901170014
Definition Number of GPRS DL TBF establishment failure due to BIU
connection failed
Description This counter counts the number of connection failure due to BIU
connection failed when BSC establishes GPRS DL TBF.
Usage This counter is used to find out the frequency of connection
failure due to BIU connection failed when BSC establishes GPRS
DL TBF (including establishing DL TBF initially and establishing
DL TBF while UL TBF already exists).
Measurement If RANPS module receives connection failed message reported by
Point connection module, and the cause of failure is BIU connection failed, the
counter increments. The measurement point is A, as shown in Figure 40.

FIGURE 40 – CONNECTION FAILURE DUE TO BIU CONNECTION FAILED

BTS BSC

PACKET CHANNEL
PACKET CHANNEL ACTIVE
ACTIVENACK
NACK
(due to BIU failure)
(原因为BIU失败)

Unit Times

C901170015
Definition Number of GPRS DL TBF channel activate establishment success
Description This counter counts the number of channel activate
establishment success when BSC establishes GPRS DL TBF.
Usage This counter is used to find out the frequency of channel activate
establishment success when BSC establishes GPRS DL TBF.
Measurement When RANPS module receives channel activate response
Point message reported by BTS and connection success response
message reported by connection module, the counter increments.
The measurement point is A as shown in Figure 41.

Confidential and Proprietary Information of ZTE CORPORATION 95


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 41 - DL GPRS TBF ESTABLISHES CHANNEL ACTIVATION AND ACCESS


SUCCESS

Unit Times

C901170016
Definition Number of GPRS DL TBF establishment failure on CCCH/PCCCH
due to not receive PIA
Description This counter counts the number of DL immediate assignment
message sending failures when BSC establishes GPRS DL TBF.
Usage This counter is used to find out the frequency of DL immediate
assignment message sending failures when BSC establishes
GPRS DL TBF.
Measurement The measurement is taken at two time points listed below:
Point
„ When RANPS module receives immediate assignment
sending failure message (EV_PACKET_PIA_DEL_IND)
reported by BTS, the counter increments. The
measurement point is A, as shown in Figure 42.

FIGURE 42 – IMMEDIATE AS SIGNMENT SENDING FAILURE

„ If “wait for immediate assignment sending indication” timer


expires, and BSC has not received immediate assignment
sending message, the counter increments
Unit Times

C901170017
Definition Number of GPRS DL TBF establishment failure on CCCH/PCCCH
due to UPPB-DSP congestion
Description No statistics for this counter is meaningless to GPRS DL TBF.

96 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

C901170018
Definition Number of GPRS DL TBF establishment failure on PACCH due to
UPPB-DSP congestion
Description No statistics for this counter is meaningless to GPRS DL TBF.

C901170019
Definition Number of GPRS DL TBF establishment success on PCCCH/CCCH
Description This counter counts the number of successful DL immediate
assignment message sendings when BSC establishes GPRS DL
TBF.
Usage This counter is used to find out the frequency of GPRS DL TBF
establishment success.
Measurement When RANPS module receives successful immediate assignment
Point sending message (SPS_ABIS_PACKET_SEND_PIA_IND) reported
by BTS, the counter increments. The measurement point is A, as
shown in Figure 43.

FIGURE 43 – SUCCESSFUL IMMEDIATE AS SIGNMENT SENDING

Unit Times

C901170020
Definition Number of GPRS DL TBF establishment success on PACCH
Description No statistics temporarily.

C901170023
Definition Number of GPRS DL TBF resource reallocation failure due to Abis
congestion for UL TBF establishment
Description After MS establishes GPRS DL TBF, it shall establish UL TBF on
PACCH. But resource application failure leads to DL resource

Confidential and Proprietary Information of ZTE CORPORATION 97


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

reallocation failure. This counter counts the number of DL


resource reallocation failure due to Abis congestion.
Usage This counter is used to find out the frequency of GPRS DL TBF
resource reallocation failure due to Abis congestion.
Measurement MS has established GPRS DL TBF, and after RANPS module
Point receives EV_MAC_UL_ASSIGN_REQ message sent from RANU
module, if resource application fails due to Abis congestion, the
counter increments. The measurement point is A, as shown in
Figure 44.

FIGURE 44 – RESOURCE APPLICATION F AILURE DUE TO ABIS CONGESTION


( ASSIGNED BY UL)

PS用户面 PS控制面 数据库

上行指派消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

Unit Times

C901170024
Definition Number of GPRS DL TBF resource reallocation failure due to RR
congestion for UL TBF establishment
Description After MS establishes GPRS DL TBF, it shall establish UL TBF on
PACCH. But resource application failure leads to DL resource
reallocation failure. This counter counts the number of DL
resource reallocation failure due to RR congestion.
There are three causes for RR congestion: MS per channel
(number of MS reaches the peak in each channel), TAI/TFI (no
TAI or TFI) and no PDCH (no PS channel).
Usage This counter is used to find out the frequency of GPRS DL TBF
resource reallocation failure due to RR congestion.
Measurement MS has established GPRS DL TBF, and after RANPS module
Point receives EV_MAC_UL_ASSIGN_REQ message sent from RANU
module, if resource application fails due to RR congestion, the
counter increments. The measurement point is A, as shown in
Figure 45.

98 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

FIGURE 45 – RESOURCE APPLICATION F AILURE DUE TO RR CONGESTION


( ASSIGNED BY UL)

PS用户面 PS控制面 数据库

上行指派消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

Unit Times

C901170025
Definition Number of GPRS DL TBF resource reallocation failure due to
UPPB-DSP channel congestion for UL TBF establishment
Description After MS establishes GPRS DL TBF, it shall establish UL TBF in
PACCH. But resource application failure leads to DL resource
reallocation failure. This counter counts the number of DL
resource reallocation failures due to UPPB-DSP channel
congestion.
Usage This counter is used to find out the frequency of GPRS DL TBF
resource reallocation failure due to UPPB-DSP channel
congestion.
Measurement MS has established GPRS DL TBF, and after RANPS module
Point receives EV_MAC_UL_ASSIGN_REQ message sent from RANU
module, if resource application fails due to UPPB-DSP channel
congestion, the counter increments. The measurement point is A,
as shown in Figure 46.

FIGURE 46 – RESOURCE APPLICATION F AILURE DUE TO UPPB-DSP CHANNEL


CONGESTION (ASSIGNED BY UL)

PS用户面 PS控制面 数据库

上行指派消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 99


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901170026
Definition Number of GPRS DL TBF resource reallocation success due to UL
TBF establishment
Description After MS establishes GPRS DL TBF, it shall establish UL TBF in
PACCH. This counter counts the number of DL resource
application success.
Usage This counter is used to find out the frequency of GPRS DL TBF
resource reallocation success.
Measurement MS has established GPRS DL TBF, and after RANPS module
Point receives EV_MAC_UL_ASSIGN_REQ message sent from RANU
module, if resource application succeeds, the counter increments.
The measurement point is A, as shown in Figure 47.

FIGURE 47 – SUCCESSFUL RESOURCE APPLICATION ( ASSIGNED BY UL)

PS用户面 PS控制面 数据库

上行指派消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

Unit Times

C901170027
Definition Number of allocated PDCH for GPRS DL TBF resource
reallocation due to UL TBF establishment
Description This counter counts the number of successfully allocated PDCH
when GPRS DL TBF resource is reallocated.
Usage This counter is used to find out the number of successfully
allocated PDCH when GPRS DL TBF resource is reallocated.
Measurement MS has established GPRS DL TBF, and after RANPS module
Point receives EV_MAC_UL_ASSIGN_REQ message sent from RANU
module, when resource application succeeds, the counter
accumulates the PDTCH number. The measurement point is A,
as shown in Figure 47.
Unit Times

100 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

C901170028
Definition Number of GPRS DL TBF resource reallocation failure due to
channel activate failure for UL TBF establishment
Description This counter counts the number of PDCH activate failure during
the process of GPRS DL TBF resource reallocation.
Usage This counter is used to find out the frequency of PDCH activate
failure during the process of GPRS DL TBF resource reallocation.
Measurement The measurement is taken at two time points listed below:
Point
„ When BSC receives PDCH activate failure message reported
by BTS, the counter increments. The measurement point is A,
as shown in Figure 38.
„ If “wait for PDCH activate & connection response” timer
expires, and BSC has not received PDCH activate response
message reported by BTS, the counter increments.
Unit Times

C901170029
Definition Number of GPRS DL TBF resource reallocation failure due to BTS
connection failure for UL TBF establishment
Description This counter counts the number of connection failure due to BTS
connection failure during the process of GPRS DL TBF resource
reallocation.
Usage This counter is used to find out the frequency of connection
failure due to BTS connection failure during the process of GPRS
DL TBF resource reallocation.
Measurement The measurement is taken at two time points listed below:
Point
„ If RANPS module receives connection failure message
reported by connection module, and the cause of failure is
BTS connection failure, the counter increments. The
measurement point is A, as shown in Figure 39.
„ If “wait for PDCH activation & connection response” timer
expires, and BSC has not received connection success
response message reported by connection module, the
counter increments.
Unit Times

C901170030
Definition Number of GPRS DL TBF resource reallocation failure due to BIU
connection failure for UL TBF establishment

Confidential and Proprietary Information of ZTE CORPORATION 101


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Description This counter counts the number of connection failure due to BIU
connection failure during the process of GPRS DL TBF resource
reallocation.
Usage This counter is used to find out the frequency of connection
failure due to BIU connection failure during the process of GPRS
DL TBF resource reallocation.
Measurement If RANPS module receives connection failure message reported
Point by connection module, and the cause of failure is BIU connection
failure, the counter increments. The measurement point is A, as
shown in Figure 40.
Unit Times

C901170031
Definition Number of GPRS DL TBF resource reallocation success of channel
activate for UL TBF establishment
Description This counter counts the number of channel activate success
during the process of GPRS DL TBF resource reallocation.
Usage This counter is used to find out the frequency of channel activate
success during the process of GPRS DL TBF resource reallocation.
Measurement When RANPS module receives channel activate response
Point message reported by BTS and connection success response
message reported by connection module, the counter increments.
The measurement point is A, as shown in Figure 48.

FIGURE 48 – SUCCESSFUL ACTIVATION AND CONNECTION

BTS 接续模块 PS控制面

PACKET CONNECT ACK


PACKET CHANNEL ACTIVE ACK
A

Unit Times

C901170032
Definition Number of GPRS DL TBF resource reallocation failure due to UL
TBF establishment
Description No statistics for this counter is meaningless to GPRS DL TBF.

102 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

C901170033
Definition Number of GPRS DL TBF resource reallocation success due to UL
TBF establishment
Description No statistics for this counter is meaningless to GPRS DL TBF.

C901170036
Definition Number of GPRS DL TBF resource reallocation failure due to Abis
congestion for LLC transmission
Description During GPRS DL TBF transmission, MAC sends resource
adjustment message (EV_MAC_RESOURCE_ADJU_REQ) to
RANPS due to UL/DL LLC changes. RANPS applies for resource
after it receives the message. This counter counts the number of
resource application failures after RANPS receives resource
adjustment request during GPRS DL TBF transmission (the cause
of database application failure is Abis congestion).
Usage This counter is used to find out the frequency of resource
application failures after RANPS receives resource adjustment
request during GPRS DL TBF transmission (the cause of
database application failure is Abis congestion).
Measurement After RANPS module receives EV_MAC_RESOURCE_ADJU_REQ
Point message sent from MAC, if resource application fails due to Abis
congestion, the counter increments. The measurement point is A,
as shown in Figure 49.

FIGURE 49 – RESOURCE APPLICATION F AILURE DUE TO ABIS CONGESTION


(RESOURCE ADJUSTMENT)

PS用户面 PS控制面 数据库

上行指派消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

Unit Times

C901170037
Definition Number of GPRS DL TBF resource reallocation failure due to RR
congestion for LLC transmission

Confidential and Proprietary Information of ZTE CORPORATION 103


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Description During GPRS DL TBF transmission, MAC sends resource


adjustment message (EV_MAC_RESOURCE_ADJU_REQ) to
RANPS due to UL/DL LLC changes. RANPS applies for resource
after it receives the message. This counter counts the number of
resource application failures after RANPS receives resource
adjustment request during GPRS DL TBF transmission (the cause
of database application failure is RR congestion).
There are three causes for RR congestion: MS per channel
(number of MS reaches the peak in each channel), TAI/TFI (no
TAI or TFI) and no PDCH (no PS channel).
Usage This counter is used to find out the frequency of resource
application failures after RANPS receives resource adjustment
request during GPRS DL TBF transmission (the cause of
database application failure is RR congestion).
Measurement After RANPS module receives EV_MAC_RESOURCE_ADJU_REQ
Point message sent from MAC, if resource application fails due to RR
congestion, the counter increments. The measurement point is A,
as shown in Figure 50.

FIGURE 50 – RESOURCE APPLICATION F AILURE DUE TO RR CONGESTION


(RESOURCE ADJUSTMENT)

PS用户面 PS控制面 数据库

上行指派消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

Unit Times

C901170038
Definition Number of GPRS DL TBF resource reallocation failure due to
UPPB-DSP channel congestion for LLC transmission
Description During GPRS DL TBF transmission, MAC sends resource
adjustment message (EV_MAC_RESOURCE_ADJU_REQ) to
RANPS due to UL/DL LLC changes. RANPS applies for resource
after it receives the message. This counter counts the number of
resource reallocation failure after RANPS receives resource
adjustment request during GPRS DL TBF transmission (the cause
of database application failure is UPPB-DSP channel congestion).
Usage This counter is used to find out the frequency of resource
reallocation failure after RANPS receives resource adjustment

104 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

request during GPRS DL TBF transmission (the cause of


database application failure is UPPB-DSP channel congestion).
Measurement After RANPS module receives EV_MAC_RESOURCE_ADJU_REQ
Point message sent from MAC, if resource application fails due to
UPPB-DSP channel congestion, the counter increments. The
measurement point is A, as shown in Figure 51.

FIGURE 51 – RESOURCE APPLICATION F AILURE DUE TO UPPB-DSP CHANNEL


CONGESTION (RESOURCE ADJUSTMENT)

PS用户面 PS控制面 数据库

上行指派消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

Unit Times

C901170039
Definition Number of GPRS DL TBF resource reallocation success due to
LLC transmission
Description During GPRS DL TBF transmission, MAC sends resource
adjustment message (EV_MAC_RESOURCE_ADJU_REQ) to
RANPS due to UL/DL LLC changes. RANPS applies for resource
after it receives the message. This counter counts the number of
resource reallocation success after RANPS receives resource
adjustment request during GPRS DL TBF transmission.
Usage This counter is used to find out the frequency of resource
reallocation success after RANPS receives resource adjustment
request during GPRS DL TBF transmission.
Measurement After RANPS module receives EV_MAC_RESOURCE_ADJU_REQ
Point message sent from MAC, if resource application succeeds, the
counter increments. The measurement point is A, as shown in
Figure 52.

Confidential and Proprietary Information of ZTE CORPORATION 105


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 52 – SUCCESSFUL RESOURCE APPLICATION (RESOURCE


ADJUSTMENT)

PS用户面 PS控制面 数据库

上行指派消息
申请资源

申请资源失败
(失败原因为Abis资源拥塞)

Unit Times

C901170040
Definition Number of allocated PDCH for GPRS DL TBF resource
reallocation due to LLC transmission
Description During GPRS DL TBF transmission, MAC sends resource
adjustment message (EV_MAC_RESOURCE_ADJU_REQ) to
RANPS due to UL/DL LLC changes. RANPS applies for resource
after it receives the message. This counter counts the number of
successfully allocated PDCH after RANPS receives resource
adjustment request during GPRS DL TBF transmission.
Usage This counter is used to find out the number of successfully
allocated PDCH after RANPS receives resource adjustment
request during GPRS DL TBF transmission.
Measurement After RANPS module receives EV_MAC_RESOURCE_ADJU_REQ
Point message sent from MAC, if resource application succeeds, the
counter accumulates the PDTCH number. The measurement
point is A, as shown in Figure 52.
Unit Times

C901170041
Definition Number of GPRS DL TBF resource reallocation failure due to
channel activate failure for LLC transmission
Description This counter counts the number of PDCH activate failure after
BSC receives resource adjustment request during GPRS DL TBF
transmission.
Usage This counter is used to find out the frequency of PDCH activate
failure after BSC receives resource adjustment request during
GPRS DL TBF transmission.

106 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

Measurement The measurement is taken at two time points listed below:


Point
„ When BSC receives PDCH activate failure message reported
by BTS, the counter increments. The measurement point is A,
as shown in Figure 38.
„ If “wait for PDCH activate & connection response” timer
expires, and BSC has not received PDCH activate response
message reported by BTS, the counter increments.
Unit Times

C901170042
Definition Number of GPRS DL TBF resource reallocation failure due to BTS
connection failure for LLC transmission
Description This counter counts the number of connection failure due to BTS
connection failure after BSC receives resource adjustment
request during GPRS DL TBF transmission.
Usage This counter is used to find out the frequency of connection
failure due to BTS connection failure after BSC receives resource
adjustment request during GPRS DL TBF transmission.
Measurement The measurement is taken at two time points listed below:
Point
„ If RANPS module receives connection failure message
reported by connection module, and the cause of failure is
BTS connection failure, the counter increments. The
measurement point is A, as shown in Figure 39.
„ If “wait for PDCH activate & connection response” timer
expires, and BSC has not received connection success
response message reported by connection module, the
counter increments.
Unit Times

C901170043
Definition Number of GPRS DL TBF resource reallocation failure due to BIU
connection failure for LLC transmission
Description This counter counts the number of connection failure due to BIU
connection failure after BSC receives resource adjustment
request during GPRS DL TBF transmission.
Usage This counter is used to find out the frequency of connection
failure due to BIU connection failure after BSC receives resource
adjustment request during GPRS DL TBF transmission.
Measurement If RANPS module receives connection failure message reported
Point by connection module, and the cause of failure is BIU connection
failure, the counter increments. The measurement point is A, as
shown in Figure 40.

Confidential and Proprietary Information of ZTE CORPORATION 107


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Unit Times

C901170044
Definition Number of GPRS DL TBF resource reallocation success of channel
activate for LLC transmission
Description This counter counts the number of channel activate success after
BSC receives resource adjustment request during GPRS DL TBF
transmission.
Usage This counter is used to find out the frequency of channel activate
success after BSC receives resource adjustment request during
GPRS DL TBF transmission.
Measurement When RANPS module receives channel activate response
Point message reported by BTS and connection success response
message reported by connection module, the counter increments.
The measurement point is A, as shown in Figure 48.
Unit Times

C901170045
Definition Number of GPRS DL TBF resource reallocation failure due to LLC
transmission
Description No statistics for this counter is meaningless to GPRS DL TBF.

C901170046
Definition Number of GPRS DL TBF resource reallocation success due to
LLC transmission
Description No statistics for this counter is meaningless to GPRS DL TBF.

C901170047
Definition Number of GPRS DL TBF release due to flush LL
Description This counter counts the number of GPRS DL TBF release due to
flush LL.
Usage This counter is used to find out the frequency of GPRS DL TBF
forcing Release Requests due to flush LL received by RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_RANUMC_REL_CMD) reported by RANUMC, if the cause of
release is flush LL, and GPRS DL TBF exists, the counter
increments. The measurement point is A, as shown in Figure 53.

108 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

FIGURE 53 – RELEASE REQUEST DUE TO FLUSH LL

SGSN PS PS控制面
control plane

FLUSH Internal release


控制面
for control plane
内部释放
A

Unit Times

C901170048
Definition Number of GPRS DL TBF release due to GPRS suspend requests
Description This counter counts the number of GPRS DL TBF release due to
GPRS suspend requests.
Usage This counter is used to find out the frequency of GPRS DL TBF
forcing Release Requests due to suspend requests received by
RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_RANUMC_REL_CMD) reported by RANUMC, if the cause of
release is SUSPEND, and GPRS DL TBF exists, the counter
increments. The measurement point is A, as shown in Figure 54.

FIGURE 54 – RELEASE REQUEST DUE TO SUSPEND REQUEST

SGSN PS PS控制面
control plane

SUSPEND
FLUSH Internal release
控制面
for control plane
内部释放
A

Unit Times

C901170049
Definition Number of GPRS DL TBF forcing release by CS
Description This counter counts the number of GPRS DL TBF forcing release
by CS due to PDCH REL.
Usage This counter is used to find out the frequency of GPRS DL TBF
forcing Release Requests (EV_RANCCM_PDCH_REL) received by
RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_RANCCM_PDCH_REL) reported by RANCCM module, if GPRS
DL TBF exists, the counter increments. The measurement point
is A, as shown in Figure 55.

Confidential and Proprietary Information of ZTE CORPORATION 109


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 55 – RELEASE REQUEST DUE TO PDCH REL

CS control
SGSNplane PS PS控制面
control plane

PDCHFLUSH
RELEASE
控制面
内部释放
A

Unit Times

C901170050
Definition Number of GPRS DL TBF normal release due to user plane
requests
Description This counter counts the number of GPRS DL TBF normal release
due to normal Release Request by MAC.
Usage This counter is used to find out the frequency of GPRS DL TBF
forcing Release Requests due to normal Release Request by MAC
received by RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_MAC_REL_IND) reported by MAC, if the cause of release is
normal Release Request by MAC, and GPRS DL TBF exists, the
counter increments. The measurement point is A, as shown in
Figure 56.

FIGURE 56 – RELEASE REQUEST DUE TO NORM AL RELEASE REQUEST BY


M AC

CS control
SGSNplane PS PS控制面
control plane
RELEASE
(Due toFLUSH
normal release) 控制面
内部释放
A

Unit Times

C901170051
Definition Number of GPRS DL TBF abnormal release due to user plane
requests
Description This counter counts the number of GPRS DL TBF abnormal
release due to abnormal Release Request by MAC.

110 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

Usage This counter is used to find out the frequency of GPRS DL TBF
forcing Release Requests due to abnormal Release Request by
MAC received by RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_MAC_REL_IND) reported by MAC, if the cause of release is
abnormal Release Request by MAC, and GPRS DL TBF exists, the
counter increments. The measurement point is A, as shown in
Figure 57.

FIGURE 57 – RELEASE REQUEST DUE TO ABNORM AL RELEASE REQUEST BY


M AC

CS control
SGSNplane PS PS控制面
control plane
RELEASE
FLUSH release)
(Due to abnormal 控制面
内部释放
A

Unit Times

C901170052
Definition Number of GPRS DL TBF release due to NSVC unavailability
Description This counter counts the number of GPRS DL TBF release due to
NSVC unavailability.
Usage This counter is used to find out the frequency of GPRS DL TBF
forcing Release Requests due to NSVC unavailability received by
RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_RANUMC_REL_CMD) reported by RANUMC, if the cause of
release is NSVC unavailability, and GPRS DL TBF exists, the
counter increments. The measurement point is A, as shown in
Figure 58.

FIGURE 58 – RELEASE REQUEST DUE TO NSVC UNAVAILABILITY

Database
SGSN PS PS控制面
control plane

NSVCFLUSH
Unavailability
控制面
内部释放
A

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 111


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901170053
Definition Number of GPRS DL TBF release due to BVC unavailability
Description This counter counts the number of GPRS DL TBF release due to
BVC unavailability.
Usage This counter is used to find out the frequency of GPRS DL TBF
forcing Release Requests due to BVC unavailability received by
RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_RANUMC_REL_CMD) reported by RANUMC, if the cause of
release is BVC unavailability, and GPRS DL TBF exists, the
counter increments. The measurement point is A, as shown in
Figure 59.

FIGURE 59 – RELEASE REQUEST DUE TO BVC UNAV AILABILITY

SGSN PS控制面

FLUSH
控制面
内部释放
A

Unit Times

C901170054
Definition Number of GPRS DL TBF release due to other reasons
Description This counter counts the number of GPRS DL TBF release due to
other reasons.
Usage This counter is used to find out the frequency of GPRS DL TBF
forcing Release Requests due to other reasons received by
RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_RANUMC_REL_CMD) reported by RANUMC, if the reason of
release is others, and GPRS DL TBF exists, the counter
increments. The measurement point is A, as shown in Figure 60.

FIGURE 60 – RELEASE REQUEST DUE TO OTHER REASONS

SGSN PS控制面

FLUSH
控制面
内部释放
A

112 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

Unit Times

C901170055
Definition Number of DL GPRS TBF grab resources
Description This counter counts the number of DL GPRS TBF grab resources.
Usage This counter is used to find out the frequency for DL GPRS TBF
grabbing other TBF resource.
Measurement This counter increments while DL GPRS TBF is established during
Point resource adjustment, resource request is successful, and other
TBF resource is grabbed. Measurement point is A as shown in
Figure 61.

FIGURE 61 - DL GPRS RESOURCE REQUEST SUCCESS

PS控制面 数据库
申请资源(下行 GPRS)

申请资源成功

Unit Times

C901170056
Definition Number of grab instance by DL GPRS TBF
Description This counter counts the number of grab instance by DL GPRS
TBF.
Usage This counter is used to find out the frequency for DL GPRS TBF
grabbing other TBF resource.
Measurement This counter increments while DL GPRS TBF is established during
Point resource adjustment, resource request is successful, and other
TBF resource is grabbed. Measurement point is A as shown in
Figure 61.
Unit Times

C901170057
Definition Number of DL GPRS TBF queuing
Description This counter counts the number of DL GPRS TBF queuing.

Confidential and Proprietary Information of ZTE CORPORATION 113


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Usage This counter is used to find out the frequency for DL GPRS TBF
queuing.
Measurement This counter increments while DL GPRS TBF is established during
Point resource adjustment, resource request is successful but queuing
is required due to incompliant to QoS rate. Measurement point is
A as shown in Figure 61.
Unit Times

C901170058
Definition Number of DL GPRS TBF queuing success
Description This counter counts the number of DL GPRS TBF queuing success.
Usage This counter is used to find out the frequency for DL GPRS TBF queuing
success.
Measurement This counter increments while DL GPRS TBF is established during
Point resource adjustment, the instance to be queued successfully assigns
resource for user plane, and database is successfully registered.
Measurement point is A as shown in Figure 62.

FIGURE 62 - RESOURCE ASSIGNMENT SUCCESS

PS控制面 PS用户面

资源指派
实例需要
排队,注
册成功
A

Unit Times

C901170059
Definition Number of DL GPRS TBF release TBF during queuing
Description This counter counts the number of DL GPRS TBF release during
queuing.
Usage This counter is used to find out the frequency for DL GPRS TBF release
during queuing.
Measurement This counter increments while DL GPRS TBF is released and instance still
Point in queuing state. The measurement point is A as shown in Figure 63.

114 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Downlink GPRS Data TBF Statistics

FIGURE 63 – RELEASE DL GPRS TBF

PSPS控制面
control plane

Release DL GPRS
释放下行GPRS
TBF, instance stillTBF,
in
实例仍在排队
queuing
A

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 115


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This page is intentionally blank.

116 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6

Downlink EGPRS Data


TBF Statistics

DL (DL) EGPRS data TBF statistics aims to measure the process


of cell-level EGPRS DL TBF establishment and release.
This chapter describes the definition, usage and measurement
point of various counters.

Overview
DL EGPRS data TBF statistics is used to observe the process of
EGPRS DL TBF establishment, maintenance and release.
The measurement takes cell as the statistics unit.

DL EGPRS Data TBF Statistics


Counter Index
Table 10 lists counters related to DL EGPRS data TBF statistics.
T A B L E 1 0 - D L E G P R S D AT A T B F S TAT I S T I C S C O U N T E R S

Counter ID What It Counts


Number of EGPRS DL TBF establishment requests
C901180002
on CCCH/PCCCH
Number of EGPRS DL TBF establishment requests
C901180003
on PACCH
Number of EGPRS DL TBF establishment failure due
C901180004
to CPU
Number of EGPRS DL TBF establishment failure due
C901180005
to not support DTM
Number of EGPRS DL TBF establishment failure due
C901180007
to Abis congestion

Confidential and Proprietary Information of ZTE CORPORATION 117


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


Number of EGPRS DL TBF establishment failure due
C901180008
to RR congestion
Number of EGPRS DL TBF establishment failure due
C901180009
to UPPB-DSP channel congestion
Number of EGPRS DL TBF establishment channel
C901180010
allocate success
Number of allocated PDCH for EGPRS DL TBF
C901180011
establishment
Number of EGPRS DL TBF establishment failure due
C901180012
to channel activate failed
Number of EGPRS DL TBF establishment failure due
C901180013
to BTS connection failed
Number of EGPRS DL TBF establishment failure due
C901180014
to BIU connection failed
Number of EGPRS DL TBF channel activate
C901180015
establishment success
Number of EGPRS DL TBF establishment failure on
C901180016
CCCH/PCCCH due to not receive PIA
Number of EGPRS DL TBF establishment failure on
C901180017
CCCH/PCCCH due to UPPB-DSP congestion
Number of EGPRS DL TBF establishment failure on
C901180018
PACCH due to UPPB-DSP congestion
Number of EGPRS DL TBF establishment success on
C901180019
PCCCH/CCCH
Number of EGPRS DL TBF establishment success on
C901180020
PACCH
Number of EGPRS DL TBF resource reallocation
C901180023 failure due to Abis congestion for UL TBF
establishment
Number of EGPRS DL TBF resource reallocation
C901180024 failure due to RR congestion for UL TBF
establishment
Number of EGPRS DL TBF resource reallocation
C901180025 failure due to UPPB-DSP channel congestion for UL
TBF establishment
Number of EGPRS DL TBF resource reallocation
C901180026
success due to UL TBF establishment
Number of allocated PDCH for EGPRS DL TBF
C901180027
resource reallocation due to UL TBF establishment
Number of EGPRS DL TBF resource reallocation
C901180028 failure due to channel activate failure for UL TBF
establishment
Number of EGPRS DL TBF resource reallocation
C901180029 failure due to BTS connection failure for UL TBF
establishment
C901180030 Number of EGPRS DL TBF resource reallocation

118 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Downlink EGPRS Data TBF Statistics

Counter ID What It Counts


failure due to BIU connection failure for UL TBF
establishment
Number of EGPRS DL TBF resource reallocation
C901180031 success of channel activate for UL TBF
establishment
Number of EGPRS DL TBF resource reallocation
C901180032
failure due to UL TBF establishment
Number of EGPRS DL TBF resource reallocation
C901180033
success due to UL TBF establishment
Number of EGPRS DL TBF resource reallocation
C901180036
failure due to Abis congestion for LLC transmission
Number of EGPRS DL TBF resource reallocation
C901180037
failure due to RR congestion for LLC transmission
Number of EGPRS DL TBF resource reallocation
C901180038 failure due to UPPB-DSP channel congestion for LLC
transmission
Number of EGPRS DL TBF resource reallocation
C901180039
success due to LLC transmission
Number of allocated PDCH for EGPRS DL TBF
C901180040
resource reallocation due to LLC transmission
Number of EGPRS DL TBF resource reallocation
C901180041 failure due to channel activate failure for LLC
transmission
Number of EGPRS DL TBF resource reallocation
C901180042 failure due to BTS connection failure for LLC
transmission
Number of EGPRS DL TBF resource reallocation
C901180043 failure due to BIU connection failure for LLC
transmission
Number of EGPRS DL TBF resource reallocation
C901180044
success of channel activate for LLC transmission
Number of EGPRS DL TBF resource reallocation
C901180045
failure due to LLC transmission
Number of EGPRS DL TBF resource reallocation
C901180046
success due to LLC transmission
C901180047 Number of EGPRS DL TBF release due to flush LL
Number of EGPRS DL TBF release due to EGPRS
C901180048
suspend requests
C901180049 Number of EGPRS DL TBF forcing release by CS
Number of EGPRS DL TBF normal release due to
C901180050
user plane requests
Number of EGPRS DL TBF abnormal release due to
C901180051
user plane requests
Number of EGPRS DL TBF release due to NSVC
C901180052
unavailability
C901180053 Number of EGPRS DL TBF release due to BVC

Confidential and Proprietary Information of ZTE CORPORATION 119


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


unavailability
Number of EGPRS DL TBF release due to other
C901180054
reasons
C901180055 Number of DL EGPRS TBF grab resources
C901180056 Number of grab instance by DL EGPRS TBF
C901180057 Number of DL EGPRS TBF queuing
C901180058 Number of DL EGPRS TBF queuing success
Number of DL EGPRS TBF release TBF during
C901180059
queuing

C901180002
Definition Number of EGPRS DL TBF establishment requests on
CCCH/PCCCH
Description This counter counts the number of DL establishment requests
received by control plane when BSC initially attempts to
establish EGPRS DL TBF.
Usage This counter is used to find out the frequency of DL
establishment requests sent from CCCH/PCCCH and received by
control plane when BSC establishes EGPRS DL TBF.
Measurement When RANPS module receives the DL request
Point (EV_RANUMC_DLASS_REQ) sent from RANUMC module, the
counter increments. This measurement point is A, as shown in
Figure 29.
Unit Times

C901180003
Definition Number of EGPRS DL TBF establishment requests on PACCH
Description This counter counts the number of establishing EGPRS DL TBF
on PACCH by MS.
Usage This counter is used to find out the frequency of establishing DL
TBF in PACCH after MS has established EGPRS UL TBF.
Measurement After MS has established EGPRS UL TBF, RANPS module receives
Point EV_MAC_DL_ASSIGN_REQ message sent from RANU module,
the counter increments. This measurement point is A, as shown
in Figure 30.
Unit Times

120 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Downlink EGPRS Data TBF Statistics

C901180004
Definition Number of EGPRS DL TBF establishment failure due to CPU
Description No statistics temporarily.

C901180005
Definition Number of EGPRS DL TBF establishment failure due to not
support DTM
Description No statistics temporarily.

C901180007
Definition Number of EGPRS DL TBF establishment failure due to Abis
congestion
Description This counter counts the number of failures that RANPS applies to
database for resource and the cause of failures is Abis
congestion when BSC attempts to establish EGPRS DL TBF.
Usage This counter is used to find out the frequency of failures that
RANPS applies to database for resource and the cause of failures
is Abis congestion when BSC attempts to establish EGPRS DL
TBF.
Measurement The measurement is taken at two time points listed below:
Point
„ After RANPS module receives DL request message
(EV_RANUMC_DLASS_REQ) sent from RANUMC module, if
resource application fails and the cause of failure is Abis
congestion, the counter increments. The measurement point
is A, as shown in Figure 31.
„ After MS establishes EGPRS UL TBF, RANPS module receives
EV_MAC_DL_ASSIGN_REQ message sent from RANU module,
if resource application fails and the cause of failure is Abis
congestion, the counter increments. The measurement point
is A, as shown in Figure 32.
Unit Times

C901180008
Definition Number of EGPRS DL TBF establishment failure due to RR
congestion
Description This counter counts the number of failures that RANPS applies to
database for resource and the cause of failures is RR congestion
when BSC attempts to establish EGPRS DL TBF. There are three

Confidential and Proprietary Information of ZTE CORPORATION 121


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

causes for RR congestion: MS per channel (number of MS


reaches the peak in each channel), TAI/TFI (no TAI or TFI) and
no PDCH (no PS channel).
Usage This counter is used to find out the frequency of failures that
RANPS applies to database for resource and the cause of failures
is RR congestion when BSC attempts to establish EGPRS DL TBF.
Measurement The measurement is taken at two time points listed below:
Point
„ After RANPS module receives DL request message
(EV_RANUMC_DLASS_REQ) sent from RANUMC module, if
resource application fails and the cause of failure is RR
congestion, the counter increments. The measurement point
is A, as shown in Figure 33.
„ After MS establishes EGPRS UL TBF, RANPS module receives
EV_MAC_DL_ASSIGN_REQ message sent from RANU module,
if resource application fails and the cause of failure is RR
congestion, the counter increments. The measurement point
is A, as shown in Figure 34.
Unit Times

C901180009
Definition Number of EGPRS DL TBF establishment failure due to UPPB-DSP
channel congestion
Description This counter counts the number of failures that RANPS applies to
database for resource and the cause of failures is UPPB-DSP
channel congestion when BSC attempts to establish EGPRS DL
TBF.
Usage This counter is used to find out the frequency of failures that
RANPS applies to database for resource and the cause of failures
is UPPB-DSP channel congestion when BSC attempts to establish
EGPRS DL TBF.
Measurement The measurement is taken at two time points listed below:
Point
„ After RANPS module receives DL request message
(EV_RANUMC_DLASS_REQ) sent from RANUMC module, if
resource application fails and the cause of failure is UPPB-
DSP channel congestion, the counter increments. The
measurement point is A, as shown in Figure 35.
„ After MS establishes EGPRS UL TBF, RANPS module receives
EV_MAC_DL_ASSIGN_REQ message sent from RANU module,
if resource application fails and the cause of failure is UPPB-
DSP channel congestion, the counter increments. The
measurement point is A, as shown in Figure 36.
Unit Times

122 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Downlink EGPRS Data TBF Statistics

C901180010
Definition Number of EGPRS DL TBF establishment channel allocate
success
Description This counter counts the number of channel allocate success
applied by RANPS when BSC attempts to establish EGPRS DL
TBF.
Usage This counter is used to find out the frequency of successful
resource application that RANPS sends when BSC attempts to
establish EGPRS DL TBF.
Measurement After RANPS module receives DL request message
Point (EV_RANUMC_DLASS_REQ) sent from RANUMC module, when
resource application succeeds, the counter increments. The
measurement point is A, as shown in Figure 37.
Unit Times

C901180011
Definition Number of allocated PDCH for EGPRS DL TBF establishment
Description This counter counts the number of successful allocated PDCH
when BSC attempts to establish EGPRS DL TBF.
Usage This counter is used to find out the number of successful
allocated PDCH when BSC attempts to establish EGPRS DL TBF.
Measurement After RANPS module receives DL request message
Point (EV_RANUMC_DLASS_REQ) sent from RANUMC module, when
resource application succeeds, the counter accumulates the
PDCH number. The measurement point is A, as shown in Figure
37.
Unit Times

C901180012
Definition Number of EGPRS DL TBF establishment failure due to channel
activate failed
Description This counter counts the number of PDCH activate failure when
BSC establishes EGPRS DL TBF.
Usage This counter is used to find out the frequency of PDCH activate
failure when BSC establishes EGPRS DL TBF (including
establishing DL TBF initially and establishing DL TBF while UL
TBF already exists).
Measurement The measurement is taken at two time points listed below:
Point

Confidential and Proprietary Information of ZTE CORPORATION 123


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

„ When BSC receives PDCH activation failure message reported


by BTS, the counter increments. The measurement point is A,
as shown in Figure 38.
„ If “wait for PDCH activate & connection response” timer
expires, and BSC has not received PDCH activate response
message reported by BTS, the counter increments.
Unit Times

C901180013
Definition Number of EGPRS DL TBF establishment failure due to BTS
connection failed
Description This counter counts the number of connection failure due to BTS
connection failed when BSC establishes EGPRS DL TBF.
Usage This counter is used to find out the frequency of connection
failure due to BTS connection failed when BSC establishes
EGPRS DL TBF (including establishing DL TBF initially and
establishing DL TBF while UL TBF already exists).
Measurement The measurement is taken at two time points listed below:
Point
„ If RANPS module receives connection failed message
reported by connection module, and the cause of failure is
BTS connection failed, the counter increments. The
measurement point is A, as shown in Figure 39.
„ If “wait for PDCH activate & connection response” timer
expires, and BSC has not received connection success
response message reported by connection module, the
counter increments.
Unit Times

C901180014
Definition Number of EGPRS DL TBF establishment failure due to BIU
connection failed
Description This counter counts the number of connection failure due to BIU
connection failed when BSC establishes EGPRS DL TBF.
Usage This counter is used to find out the frequency of connection
failure due to BIU connection failed when BSC establishes EGPRS
DL TBF (including establishing DL TBF initially and establishing
DL TBF while UL TBF already exists).
Measurement If RANPS module receives connection failed message reported by
Point connection module, and the cause of failure is BIU connection failed, the
counter increments. The measurement point is A, as shown in Figure 40.
Unit Times

124 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Downlink EGPRS Data TBF Statistics

C901180015
Definition Number of EGPRS DL TBF channel activate establishment
success
Description This counter counts the number of channel activate
establishment success when BSC establishes EGPRS DL TBF.
Usage This counter is used to find out the frequency of channel activate
establishment success when BSC establishes EGPRS DL TBF.
Measurement When RANPS module receives channel activate response
Point message reported by BTS and connection success response
message reported by connection module, the counter increments.
The measurement point is A, as shown in Figure 42.
Unit Times

C901180016
Definition Number of EGPRS DL TBF establishment failure on CCCH/PCCCH
due to not receive PIA
Description This counter counts the number of DL immediate assignment
message sending failures when BSC establishes EGPRS DL TBF.
Usage This counter is used to find out the frequency of DL immediate
assignment message sending failures when BSC establishes
EGPRS DL TBF.
Measurement The measurement is taken at two time points listed below:
Point
„ When RANPS module receives immediate assignment
sending failure message (EV_PACKET_PIA_DEL_IND)
reported by BTS, the counter increments. The measurement
point is A, as shown in Figure 43.
„ If “wait for immediate assignment sending indication” timer
expires, and BSC has not received immediate assignment
sending message, the counter increments
Unit Times

C901180017
Definition Number of EGPRS DL TBF establishment failure on CCCH/PCCCH
due to UPPB-DSP congestion
Description No statistics for this counter is meaningless to EGPRS DL TBF.

Confidential and Proprietary Information of ZTE CORPORATION 125


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901180018
Definition Number of EGPRS DL TBF establishment failure on PACCH due to
UPPB-DSP congestion
Description No statistics for this counter is meaningless to EGPRS DL TBF.

C901180019
Definition Number of EGPRS DL TBF establishment success on
PCCCH/CCCH
Description This counter counts the number of successful DL immediate
assignment message sendings when BSC establishes EGPRS DL
TBF.
Usage This counter is used to find out the frequency of EGPRS DL TBF
establishment success.
Measurement When RANPS module receives successful immediate assignment
Point sending message (SPS_ABIS_PACKET_SEND_PIA_IND) reported
by BTS, the counter increments. The measurement point is A, as
shown in Figure 44.
Unit Times

C901180020
Definition Number of EGPRS DL TBF establishment success on PACCH
Description No statistics temporarily.

C901180023
Definition Number of EGPRS DL TBF resource reallocation failure due to
Abis congestion for UL TBF establishment
Description After MS establishes EGPRS DL TBF, it shall establish UL TBF on
PACCH. But resource application failure leads to DL resource
reallocation failure. This counter counts the number of DL
resource reallocation failure due to Abis congestion.
Usage This counter is used to find out the frequency of EGPRS DL TBF
resource reallocation failure due to Abis congestion.
Measurement MS has established EGPRS DL TBF, and after RANPS module
Point receives EV_MAC_UL_ASSIGN_REQ message sent from RANU
module, if resource application fails due to Abis congestion, the
counter increments. The measurement point is A, as shown in
Figure 44.

126 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Downlink EGPRS Data TBF Statistics

Unit Times

C901180024
Definition Number of EGPRS DL TBF resource reallocation failure due to RR
congestion for UL TBF establishment
Description After MS establishes EGPRS DL TBF, it shall establish UL TBF on
PACCH. But resource application failure leads to DL resource
reallocation failure. This counter counts the number of DL
resource reallocation failure due to RR congestion.
There are three causes for RR congestion: MS per channel
(number of MS reaches the peak in each channel), TAI/TFI (no
TAI or TFI) and no PDCH (no PS channel).
Usage This counter is used to find out the frequency of EGPRS DL TBF
resource reallocation failure due to RR congestion.
Measurement MS has established EGPRS DL TBF, and after RANPS module
Point receives EV_MAC_UL_ASSIGN_REQ message sent from RANU
module, if resource application fails due to RR congestion, the
counter increments. The measurement point is A, as shown in
Figure 45.
Unit Times

C901180025
Definition Number of EGPRS DL TBF resource reallocation failure due to
UPPB-DSP channel congestion for UL TBF establishment
Description After MS establishes EGPRS DL TBF, it shall establish UL TBF in
PACCH. But resource application failure leads to DL resource
reallocation failure. This counter counts the number of DL
resource reallocation failures due to UPPB-DSP channel
congestion.
Usage This counter is used to find out the frequency of EGPRS DL TBF
resource reallocation failure due to UPPB-DSP channel
congestion.
Measurement MS has established EGPRS DL TBF, and after RANPS module
Point receives EV_MAC_UL_ASSIGN_REQ message sent from RANU
module, if resource application fails due to UPPB-DSP channel
congestion, the counter increments. The measurement point is A,
as shown in Figure 46.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 127


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901180026
Definition Number of EGPRS DL TBF resource reallocation success due to
UL TBF establishment
Description After MS establishes EGPRS DL TBF, it shall establish UL TBF in
PACCH. This counter counts the number of DL resource
application success.
Usage This counter is used to find out the frequency of EGPRS DL TBF
resource reallocation success.
Measurement MS has established EGPRS DL TBF, and after RANPS module
Point receives EV_MAC_UL_ASSIGN_REQ message sent from RANU
module, if resource application succeeds, the counter increments.
The measurement point is A, as shown in Figure 47.
Unit Times

C901180027
Definition Number of allocated PDCH for EGPRS DL TBF resource
reallocation due to UL TBF establishment
Description This counter counts the number of successfully allocated PDCH
when EGPRS DL TBF resource is reallocated.
Usage This counter is used to find out the number of successfully
allocated PDCH when EGPRS DL TBF resource is reallocated.
Measurement MS has established EGPRS DL TBF, and after RANPS module
Point receives EV_MAC_UL_ASSIGN_REQ message sent from RANU
module, when resource application succeeds, the counter
accumulates the PDTCH number. The measurement point is A,
as shown in Figure 47.
Unit Times

C901180028
Definition Number of EGPRS DL TBF resource reallocation failure due to
channel activate failure for UL TBF establishment
Description This counter counts the number of PDCH activate failure during
the process of EGPRS DL TBF resource reallocation.
Usage This counter is used to find out the frequency of PDCH activate
failure during the process of EGPRS DL TBF resource reallocation.
Measurement The measurement is taken at two time points listed below:
Point
„ When BSC receives PDCH activate failure message reported
by BTS, the counter increments. The measurement point is A,
as shown in Figure 38.

128 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Downlink EGPRS Data TBF Statistics

„ If “wait for PDCH activate & connection response” timer


expires, and BSC has not received PDCH activate response
message reported by BTS, the counter increments.
Unit Times

C901180029
Definition Number of EGPRS DL TBF resource reallocation failure due to
BTS connection failure for UL TBF establishment
Description This counter counts the number of connection failure due to BTS
connection failure during the process of EGPRS DL TBF resource
reallocation.
Usage This counter is used to find out the frequency of connection
failure due to BTS connection failure during the process of
EGPRS DL TBF resource reallocation.
Measurement The measurement is taken at two time points listed below:
Point
„ If RANPS module receives connection failure message
reported by connection module, and the cause of failure is
BTS connection failure, the counter increments. The
measurement point is A, as shown in Figure 39.
„ If “wait for PDCH activation & connection response” timer
expires, and BSC has not received connection success
response message reported by connection module, the
counter increments.
Unit Times

C901180030
Definition Number of EGPRS DL TBF resource reallocation failure due to
BIU connection failure for UL TBF establishment
Description This counter counts the number of connection failure due to BIU
connection failure during the process of EGPRS DL TBF resource
reallocation.
Usage This counter is used to find out the frequency of connection
failure due to BIU connection failure during the process of
EGPRS DL TBF resource reallocation.
Measurement If RANPS module receives connection failure message reported
Point by connection module, and the cause of failure is BIU connection
failure, the counter increments. The measurement point is A, as
shown in Figure 40.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 129


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901180031
Definition Number of EGPRS DL TBF resource reallocation success of
channel activate for UL TBF establishment
Description This counter counts the number of channel activate success
during the process of EGPRS DL TBF resource reallocation.
Usage This counter is used to find out the frequency of channel activate
success during the process of EGPRS DL TBF resource
reallocation.
Measurement When RANPS module receives channel activate response
Point message reported by BTS and connection success response
message reported by connection module, the counter increments.
The measurement point is A, as shown in Figure 48.
Unit Times

C901180032
Definition Number of EGPRS DL TBF resource reallocation failure due to UL
TBF establishment
Description No statistics for this counter is meaningless to EGPRS DL TBF.

C901180033
Definition Number of EGPRS DL TBF resource reallocation success due to
UL TBF establishment
Description No statistics for this counter is meaningless to EGPRS DL TBF.

C901180036
Definition Number of EGPRS DL TBF resource reallocation failure due to
Abis congestion for LLC transmission
Description During EGPRS DL TBF transmission, MAC sends resource
adjustment message (EV_MAC_RESOURCE_ADJU_REQ) to
RANPS due to UL/DL LLC changes. RANPS applies for resource
after it receives the message. This counter counts the number of
resource application failures after RANPS receives resource
adjustment request during EGPRS DL TBF transmission (the
cause of database application failure is Abis congestion).
Usage This counter is used to find out the frequency of resource
application failures after RANPS receives resource adjustment
request during EGPRS DL TBF transmission (the cause of
database application failure is Abis congestion).

130 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Downlink EGPRS Data TBF Statistics

Measurement After RANPS module receives EV_MAC_RESOURCE_ADJU_REQ


Point message sent from MAC, if resource application fails due to Abis
congestion, the counter increments. The measurement point is A,
as shown in Figure 49.
Unit Times

C901180037
Definition Number of EGPRS DL TBF resource reallocation failure due to RR
congestion for LLC transmission
Description During EGPRS DL TBF transmission, MAC sends resource
adjustment message (EV_MAC_RESOURCE_ADJU_REQ) to
RANPS due to UL/DL LLC changes. RANPS applies for resource
after it receives the message. This counter counts the number of
resource application failures after RANPS receives resource
adjustment request during EGPRS DL TBF transmission (the
cause of database application failure is RR congestion).
There are three causes for RR congestion: MS per channel
(number of MS reaches the peak in each channel), TAI/TFI (no
TAI or TFI) and no PDCH (no PS channel).
Usage This counter is used to find out the frequency of resource
application failures after RANPS receives resource adjustment
request during EGPRS DL TBF transmission (the cause of
database application failure is RR congestion).
Measurement After RANPS module receives EV_MAC_RESOURCE_ADJU_REQ
Point message sent from MAC, if resource application fails due to RR
congestion, the counter increments. The measurement point is A,
as shown in Figure 50.
Unit Times

C901180038
Definition Number of EGPRS DL TBF resource reallocation failure due to
UPPB-DSP channel congestion for LLC transmission
Description During EGPRS DL TBF transmission, MAC sends resource
adjustment message (EV_MAC_RESOURCE_ADJU_REQ) to
RANPS due to UL/DL LLC changes. RANPS applies for resource
after it receives the message. This counter counts the number of
resource reallocation failure after RANPS receives resource
adjustment request during EGPRS DL TBF transmission (the
cause of database application failure is UPPB-DSP channel
congestion).
Usage This counter is used to find out the frequency of resource
reallocation failure after RANPS receives resource adjustment
request during EGPRS DL TBF transmission (the cause of
database application failure is UPPB-DSP channel congestion).

Confidential and Proprietary Information of ZTE CORPORATION 131


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Measurement After RANPS module receives EV_MAC_RESOURCE_ADJU_REQ


Point message sent from MAC, if resource application fails due to
UPPB-DSP channel congestion, the counter increments. The
measurement point is A, as shown in Figure 51.
Unit Times

C901180039
Definition Number of EGPRS DL TBF resource reallocation success due to
LLC transmission
Description During EGPRS DL TBF transmission, MAC sends resource
adjustment message (EV_MAC_RESOURCE_ADJU_REQ) to
RANPS due to UL/DL LLC changes. RANPS applies for resource
after it receives the message. This counter counts the number of
resource reallocation success after RANPS receives resource
adjustment request during EGPRS DL TBF transmission.
Usage This counter is used to find out the frequency of resource
reallocation success after RANPS receives resource adjustment
request during EGPRS DL TBF transmission.
Measurement After RANPS module receives EV_MAC_RESOURCE_ADJU_REQ
Point message sent from MAC, if resource application succeeds, the
counter increments. The measurement point is A, as shown in
Figure 52.
Unit Times

C901180040
Definition Number of allocated PDCH for EGPRS DL TBF resource
reallocation due to LLC transmission
Description During EGPRS DL TBF transmission, MAC sends resource
adjustment message (EV_MAC_RESOURCE_ADJU_REQ) to
RANPS due to UL/DL LLC changes. RANPS applies for resource
after it receives the message. This counter counts the number of
successfully allocated PDCH after RANPS receives resource
adjustment request during EGPRS DL TBF transmission.
Usage This counter is used to find out the number of successfully
allocated PDCH after RANPS receives resource adjustment
request during EGPRS DL TBF transmission.
Measurement After RANPS module receives EV_MAC_RESOURCE_ADJU_REQ
Point message sent from MAC, if resource application succeeds, the
counter accumulates the PDTCH number. The measurement
point is A, as shown in Figure 52.
Unit Times

132 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Downlink EGPRS Data TBF Statistics

C901180041
Definition Number of EGPRS DL TBF resource reallocation failure due to
channel activate failure for LLC transmission
Description This counter counts the number of PDCH activate failure after
BSC receives resource adjustment request during EGPRS DL TBF
transmission.
Usage This counter is used to find out the frequency of PDCH activate
failure after BSC receives resource adjustment request during
EGPRS DL TBF transmission.
Measurement The measurement is taken at two time points listed below:
Point
„ When BSC receives PDCH activate failure message reported
by BTS, the counter increments. The measurement point is A,
as shown in Figure 38.
„ If “wait for PDCH activate & connection response” timer
expires, and BSC has not received PDCH activate response
message reported by BTS, the counter increments.
Unit Times

C901180042
Definition Number of EGPRS DL TBF resource reallocation failure due to
BTS connection failure for LLC transmission
Description This counter counts the number of connection failure due to BTS
connection failure after BSC receives resource adjustment
request during EGPRS DL TBF transmission.
Usage This counter is used to find out the frequency of connection
failure due to BTS connection failure after BSC receives resource
adjustment request during EGPRS DL TBF transmission.
Measurement The measurement is taken at two time points listed below:
Point
„ If RANPS module receives connection failure message
reported by connection module, and the cause of failure is
BTS connection failure, the counter increments. The
measurement point is A, as shown in Figure 39.
„ If “wait for PDCH activate & connection response” timer
expires, and BSC has not received connection success
response message reported by connection module, the
counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 133


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901180043
Definition Number of EGPRS DL TBF resource reallocation failure due to
BIU connection failure for LLC transmission
Description This counter counts the number of connection failure due to BIU
connection failure after BSC receives resource adjustment
request during EGPRS DL TBF transmission.
Usage This counter is used to find out the frequency of connection
failure due to BIU connection failure after BSC receives resource
adjustment request during EGPRS DL TBF transmission.
Measurement If RANPS module receives connection failure message reported
Point by connection module, and the cause of failure is BIU connection
failure, the counter increments. The measurement point is A, as
shown in Figure 40.
Unit Times

C901180044
Definition Number of EGPRS DL TBF resource reallocation success of
channel activate for LLC transmission
Description This counter counts the number of channel activate success after
BSC receives resource adjustment request during EGPRS DL TBF
transmission.
Usage This counter is used to find out the frequency of channel activate
success after BSC receives resource adjustment request during
EGPRS DL TBF transmission.
Measurement When RANPS module receives channel activate response
Point message reported by BTS and connection success response
message reported by connection module, the counter increments.
The measurement point is A, as shown in Figure 48.
Unit Times

C901180045
Definition Number of EGPRS DL TBF resource reallocation failure due to
LLC transmission
Description No statistics for this counter is meaningless to EGPRS DL TBF.

C901180046
Definition Number of EGPRS DL TBF resource reallocation success due to
LLC transmission

134 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Downlink EGPRS Data TBF Statistics

Description No statistics for this counter is meaningless to EGPRS DL TBF.

C901180047
Definition Number of EGPRS DL TBF release due to flush LL
Description This counter counts the number of EGPRS DL TBF release due to
flush LL.
Usage This counter is used to find out the frequency of EGPRS DL TBF
forcing Release Requests due to flush LL received by RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_RANUMC_REL_CMD) reported by RANUMC, if the cause of
release is flush LL, and EGPRS DL TBF exists, the counter
increments. The measurement point is A, as shown in Figure 53.
Unit Times

C901180048
Definition Number of EGPRS DL TBF release due to EGPRS suspend
requests
Description This counter counts the number of EGPRS DL TBF release due to
EGPRS suspend requests.
Usage This counter is used to find out the frequency of EGPRS DL TBF
forcing Release Requests due to suspend requests received by
RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_RANUMC_REL_CMD) reported by RANUMC, if the cause of
release is SUSPEND, and EGPRS DL TBF exists, the counter
increments. The measurement point is A, as shown in Figure 54.
Unit Times

C901180049
Definition Number of EGPRS DL TBF forcing release by CS
Description This counter counts the number of EGPRS DL TBF forcing release
by CS due to PDCH REL.
Usage This counter is used to find out the frequency of EGPRS DL TBF
forcing Release Requests (EV_RANCCM_PDCH_REL) received by
RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_RANCCM_PDCH_REL) reported by RANCCM module, if
EGPRS DL TBF exists, the counter increments. The measurement
point is A, as shown in Figure 55.

Confidential and Proprietary Information of ZTE CORPORATION 135


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Unit Times

C901180050
Definition Number of EGPRS DL TBF normal release due to user plane
requests
Description This counter counts the number of EGPRS DL TBF normal release
due to normal Release Request by MAC.
Usage This counter is used to find out the frequency of EGPRS DL TBF
forcing Release Requests due to normal Release Request by MAC
received by RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_MAC_REL_IND) reported by MAC, if the cause of release is
normal Release Request by MAC, and EGPRS DL TBF exists, the
counter increments. The measurement point is A, as shown in
Figure 56.
Unit Times

C901180051
Definition Number of EGPRS DL TBF abnormal release due to user plane
requests
Description This counter counts the number of EGPRS DL TBF abnormal
release due to abnormal Release Request by MAC.
Usage This counter is used to find out the frequency of EGPRS DL TBF
forcing Release Requests due to abnormal Release Request by
MAC received by RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_MAC_REL_IND) reported by MAC, if the cause of release is
abnormal Release Request by MAC, and EGPRS DL TBF exists,
the counter increments. The measurement point is A, as shown
in Figure 57.
Unit Times

C901180052
Definition Number of EGPRS DL TBF release due to NSVC unavailability
Description This counter counts the number of EGPRS DL TBF release due to
NSVC unavailability.
Usage This counter is used to find out the frequency of EGPRS DL TBF
forcing Release Requests due to NSVC unavailability received by
RANPS.

136 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Downlink EGPRS Data TBF Statistics

Measurement When RANPS module receives Release Request message


Point (EV_RANUMC_REL_CMD) reported by RANUMC, if the cause of
release is NSVC unavailability, and EGPRS DL TBF exists, the
counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C901180053
Definition Number of EGPRS DL TBF release due to BVC unavailability
Description This counter counts the number of EGPRS DL TBF release due to
BVC unavailability.
Usage This counter is used to find out the frequency of EGPRS DL TBF
forcing Release Requests due to BVC unavailability received by
RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_RANUMC_REL_CMD) reported by RANUMC, if the cause of
release is BVC unavailability, and EGPRS DL TBF exists, the
counter increments. The measurement point is A, as shown in
Figure 59.
Unit Times

C901180054
Definition Number of EGPRS DL TBF release due to other reasons
Description This counter counts the number of EGPRS DL TBF release due to
other reasons.
Usage This counter is used to find out the frequency of EGPRS DL TBF
forcing Release Requests due to other reasons received by
RANPS.
Measurement When RANPS module receives Release Request message
Point (EV_RANUMC_REL_CMD) reported by RANUMC, if the reason of
release is others, and EGPRS DL TBF exists, the counter
increments. The measurement point is A, as shown in Figure 60.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 137


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This page is intentionally blank.

138 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7

Uplink GPRS Data TBF


Statistics

UL GPRS data TBF statistics collects information about the


process of establishment and release of UL GPRS TBF(cell). This
chapter contains detailed information about counters related to
UL GPRS data TBF statistic.

Overview
UL GPRS data TBF statistics collects the information about the
establishment, maintain and release of UL GPRS TBF. The
statistic unit is cell.

UL GPRS Data TBF Statistics


Counter Index
Table 11 lists counters related to UL GPRS data TBF statistics.

TABLE 11 - UL GPRS DAT A TBF STATISTICS COUNTER

Counter ID What It Counts


Number of GPRS UL TBF establishment
C901190002
requests on CCCH
Number of EGPRS UL TBF establishment
C901190003
requests on CCCH
Number of GPRS UL TBF establishment
C901190004
requests on PCCCH
Number of EGPRS UL TBF establishment
C901190005
requests on PCCCH
Number of GPRS UL TBF establishment
C901190006
requests on PACCH

Confidential and Proprietary Information of ZTE CORPORATION 139


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


Number of cell attempts for UL assignment
C901190007
due to ONE PHASE access
Number of cell attempts for UL assignment
C901190008
due to single block packet access
Number of cell attempts for UL assignment
C901190009
due to response paging

Number of cell attempts for UL assignment


C901190010
due to cell updating

Number of cell attempts for UL assignment


C901190011
due to mobility management

Number of cell attempts for UL assignment


C901190012
due to TWO PHASE access

Number of cell attempts for UL assignment


C901190013
due to short access

Number of GPRS UL TBF establishment


C901190015 failure due to Abis congestion

Number of GPRS UL TBF establishment


C901190016 failure due to RR congestion

Number of GPRS UL TBF establishment


C901190017 failure due to UPPB-DSP channel
congestion
Number of GPRS UL TBF establishment
C901190018 channel allocate success

Number of cell success for GPRS UL


C901190019 assignment due to ONE PHASE access

Number of cell success for GPRS UL


C901190020 assignment due to single block packet
access
Number of cell success for GPRS UL
C901190021 assignment due to response paging

Number of cell success for GPRS UL


C901190022 assignment due to cell updating

Number of cell success for GPRS UL


C901190023 assignment due to mobility management

Number of cell success for GPRS UL


C901190024 assignment due to TWO PHASE access

Number of cell success for GPRS UL


C901190025 assignment due to short access

140 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

Counter ID What It Counts


Number of allocated PDCH for GPRS UL
C901190026 TBF establishment

Number of GPRS UL TBF establishment


C901190027 failure due to channel activate failed

Number of GPRS UL TBF establishment


C901190028 failure due to BTS connection failed

Number of GPRS UL TBF establishment


C901190029 failure due to BIU connection failed

Number of GPRS UL TBF channel activate


C901190030 establishment success

Number of GPRS UL TBF establishment


C901190031 failure due to not receive PIA

Number of GPRS UL TBF establisment


C901190032 failure on PCCCH/CCCH due to UPPB-DSP
congestion
Number of GPRS UL TBF establisment
C901190033 failure on PACCH due to UPPB-DSP
congestion
Number of GPRS UL TBF establishment
C901190034 success on PCCCH/CCCH

Number of GPRS UL TBF establishment


C901190035 success on PACCH

Number of GPRS UL TBF resource


C901190038 reallocation failure due to Abis congestion
for DL TBF establishment
Number of GPRS UL TBF resource
C901190039 reallocation failure due to RR congestion
for DL TBF establishment
Number of GPRS UL TBF resource
reallocation failure due to UPPB-DSP
C901190040
channel congestion for DL TBF
establishment
Number of GPRS UL TBF resource
C901190041 reallocation success due to DL TBF
establishment
Number of allocated PDCH for GPRS UL
C901190042 TBF resource reallocation due to DL TBF
establishment
Number of GPRS UL TBF resourse
C901190043 reallocation failure due to channel activate
failure for DL TBF establishment
Number of GPRS UL TBF resourse
C901190044 reallocation failure due to BTS connection
failure for DL TBF establishment

Confidential and Proprietary Information of ZTE CORPORATION 141


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


Number of GPRS UL TBF resourse
C901190045 reallocation failure due to BIU connection
failure for DL TBF establishment
Number of GPRS UL TBF resourse
C901190046 reallocation success of channel activate for
DL TBF establishment
Number of GPRS UL TBF resourse
C901190047 reallocation failure due to DL TBF
establishment
Number of GPRS UL TBF resourse
C901190048 reallocation success due to DL TBF
establishment
Number of GPRS UL TBF resource
C901190051 reallocation failure due to Abis congestion
for LLC transmission
Number of GPRS UL TBF resource
C901190052 reallocation failure due to RR congestion
for LLC transmission
Number of GPRS UL TBF resource
C901190053 reallocation failure due to UPPB-DSP
channel congestion for LLC transmission
Number of GPRS UL TBF resource
C901190054 reallocation success due to LLC
transmission
Number of allocated PDCH for GPRS UL
C901190055 TBF resource reallocation due to LLC
transmission
Number of GPRS UL TBF resourse
C901190056 reallocation failure due to channel activate
failure for LLC transmission
Number of GPRS UL TBF resourse
C901190057 reallocation failure due to BTS connection
failure for LLC transmission
Number of GPRS UL TBF resourse
C901190058 reallocation failure due to BIU connection
failure for LLC transmission
Number of GPRS UL TBF resourse
C901190059 reallocation success of channel activate for
LLC transmission
Number of GPRS UL TBF resourse
C901190060 reallocation failure due to LLC transmission

Number of GPRS UL TBF resourse


C901190061 reallocation success due to LLC
transmission
Number of GPRS UL TBF resource
C901190064 reallocation failure due to Abis congestion
for resource request

142 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

Counter ID What It Counts


Number of GPRS UL TBF resource
C901190065 reallocation failure due to RR congestion
for resource request
Number of GPRS UL TBF resource
C901190066 reallocation failure due to UPPB-DSP
channel congestion for resource request
Number of GPRS UL TBF resource
C901190067 reallocation success due to resource
request
Number of allocated PDCH for GPRS UL
C901190068 TBF resource reallocation due to resource
request
Number of GPRS UL TBF resourse
C901190069 reallocation failure due to channel activate
failure for resource request
Number of GPRS UL TBF resourse
C901190070 reallocation failure due to BTS connection
failure for resource request
Number of GPRS UL TBF resourse
C901190071 reallocation failure due to BIU connection
failure for resource request
Number of GPRS UL TBF resourse
C901190072 reallocation success of channel activate for
resource request
Number of GPRS UL TBF resourse
C901190073 reallocation failure due to resource request

Number of GPRS UL TBF resourse


C901190074 reallocation success due to resource
request
Number of GPRS UL TBF release due to
C901190075 flush LL

Number of GPRS UL TBF release due to


C901190076 GPRS suspend requests

Number of GPRS UL TBF forcing release by


C901190077 CS

Number of GPRS UL TBF normal release


C901190078 due to user plane requests

Number of GPRS UL TBF abnormal release


C901190079 due to user plane requests

Number of GPRS UL TBF release due to


C901190080 NSVC unavailability

Number of GPRS UL TBF release due to


C901190081 BVC unavailability

Confidential and Proprietary Information of ZTE CORPORATION 143


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


Number of GPRS UL TBF release due to
C901190082 other reasons

Number of UL GPRS TBF grab resources


C901190083

Number of grab instance by UL GPRS TBF


C901190084

Number of UL GPRS TBF queuing


C901190085

Number of UL GPRS TBF queuing success


C901190086

Number of UL GPRS TBF release TBF


C901190087 during queuing

C901190002
Definition Number of GPRS UL TBF establishment requests on CCCH
Description This counter counts the number of channel requests on CCCH
when MS using GPRS service
Usage This counter is used to find out the frequency of channel
requests on CCCH when MS attempts using GPRS service.
Measurement When BSC receives channel requests on CCCH from MS, the
Point counter increments. The measurement point is A, as shown in
Figure 64.

FIGURE 64 - CHANNEL REQUEST

BTS BSC

Channel Request

Unit Times

C901190003
Definition Number of EGPRS UL TBF establishment requests on CCCH
Description This counter is not meaningful in UL GPRS TBF and is not used.

144 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

C901190004
Definition Number of GPRS UL TBF establishment requests on PCCCH
Description This counter counts the number of packet channel requests on
PCCCH when MS attempts using GPRS service
Usage This counter is used to find out the frequency of channel
requests on PCCCH when MS attempts using GPRS service.
Measurement When BSC receives channel requests on PCCCH from MS, the
Point counter increments. The measurement point is A, as shown in
Figure 65.

FIGURE 65 - PACKET CHANNEL REQUEST

Unit Times

C901190005
Definition Number of EGPRS UL TBF establishment requests on PCCCH
Description This counter is not meaningful in UL GPRS TBF statistic, and is
not used.

C901190006
Definition Number of GPRS UL TBF establishment requests on PACCH
Description The counter counts the number of UL GPRS TBF establishment
attempts on PACCH.
Usage This counter is used to find out the number of UL GPRS TBF
establishment attempts on PACCH under the situation when DL
GPRS TBF is already established.
Measurement In the situation when DL GPRS TBF is established, PS control
Point plane receives UL assignment request message from PS user
plane, the counter increments. The measurement point is A, as
shown in Figure 66.

Confidential and Proprietary Information of ZTE CORPORATION 145


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 66 – UL ASSIGNMENT REQUEST (DL GPRS TBF ALREADY


ESTABLISHED)

Unit Times

C901190007
Definition Number of cell attempts for UL assignment due to ONE PHASE
access
Description This counter counts the number of channel requests on CCCH
when MS attempting UL GPRS TBF establishment or the number
of packet channel requests on PCCCH due to one phase access.
Usage This counter is used to find out the number of UL GPRS TBF
establishment attempts due to one phase access.
Measurement The counter accumulates at the following two time points:
Point
„ If BSC receives channel requests from MS on CCCH due to
one phase access, the counter increments. The measurement
point is A, as shown in Figure 67.

FIGURE 67 - CHANNEL REQUESTS ON CCCH DUE TO ONE PHASE ACCESS

„ If BSC receives channel requests from MS on CCCH due to


one phase access, the counter increments. The measurement
point is A, as shown in Figure 68.

FIGURE 68 - PACKET CHANNEL REQUESTS ON CCCH DUE TO ONE PHASE


ACCESS

146 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

Unit Times

C901190008
Definition Number of cell attempts for UL assignment due to single block
packet access
Description This counter counts the number of packet channel requests on
PCCCH when MS attempts UL GPRS TBF establishment due to
single block packet access.
Usage This counter is used to find out the number of packet channel
requests when MS attempting UL GPRS TBF establishment due
to single block packet access.
Measurement If BSC receives channel requests on PCCCH from MS due to
Point single block packet access. The measurement point is A, as
shown in Figure 69.

FIGURE 69 - CHANNEL REQUEST DUE TO SINGLE BLOCK P ACKET ACCESS

Unit Times

C901190009
Definition Number of cell attempts for UL assignment due to response
paging
Description This counter counts the number of packet channel requests
when MS attempting UL GPRS TBF establishment due to
response paging.
Usage This counter is used to find out the number of packet channel
requests when MS attempting UL GPRS TBF establishment due
to response paging.
Measurement When BSC receives channel requests on PCCCH from MS due to
Point response paging, the counter increments. The measurement
point is A, as shown in Figure 70.

Confidential and Proprietary Information of ZTE CORPORATION 147


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 70 - CHANNEL REQUEST DUE TO RESPONSE P AGING

BTS BSC

Packet Channel Request(due to response


paging)
A

Unit Times

C901190010
Definition Number of cell attempts for UL assignment due to cell updating
Description This counter counts the number of packet channel requests
when MS attempting UL GPRS TBF establishment due to cell
update.
Usage This counter is used to find out the number of packet channel
requests when MS attempting UL GPRS TBF establishment due
to cell update.
Measurement When BSC receives channel requests on PCCCH from MS duet to
Point cell update, the counter increments. The measurement point is A,
as shown in Figure 71.

FIGURE 71 - CHANNEL REQUESTS DUE TO CELL UPDATE

Unit Times

C901190011
Definition Number of cell attempts for UL assignment due to mobility
management.
Description The counter counts the number of packet channel requests on
PCCCH when MS attempting UL GPRS TBF establishment due to
mobile management.
Usage This counter is used to find out the number of packet channel
requests when MS attempting UL GPRS TBF establishment due
to mobile management.

148 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

Measurement If BSC receives channel requests on PCCCH from MS due to


Point mobile management, the counter increments. The measurement
point is A, as shown in Figure 72.

FIGURE 72 - CHANNEL REQUESTS DUE TO MOBILE MAN AGEMENT

Unit Times

C901190012
Definition Number of cell attempts for UL assignment due to TWO PHASE
access
Description This counter counts the number of channel requests on CCCH
when MS attempting UL GPRS TBF establishment or the number
of packet channel requests on PCCCH due to two phase access.
Usage This counter is used to find out the number of UL GPRS TBF
establishment attempts due to two phase access.
Measurement The counter accumulates at the following two time points:
Point
„ If BSC receives channel requests from MS on CCCH due to
two phase access, the counter increments. The measurement
point is A, as shown in Figure 73.

FIGURE 73 - CHANNEL REQUESTS ON CCCH DUE TO TWO PHASE ACCESS

BTS BSC

Channel Request(due to two phase


access)
A

„ If BSC receives channel requests from MS on CCCH due to


one phase access, the counter increments. The measurement
point is A, as shown in Figure 74.

Confidential and Proprietary Information of ZTE CORPORATION 149


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 74 - PACKET CHANNEL REQUESTS ON PCCCH DUE TO TWO PHASE


ACCESS

BTS BSC

Packet Channel Request(due to two phase


access)
A

Unit Times

C901190013
Definition Number of cell attempts for UL assignment due to short access
Description This counter counts the number of packet channel requests on
PCCCH when MS attempting UL GPRS TBF establishment due to
short access.
Usage This counter is used to find out the number of UL GPRS TBF
establishment attempts due to short access.
Measurement If BSC receives packet channel requests on PCCCH from MS on
Point PCCCH due to short access, the counter increments. The
measurement point is A, as shown in Figure 75.

FIGURE 75 - PACKET CHANNEL REQUESTS ON PCCCH DUE TO SHORT


ACCESS

Unit Times

C901190015
Definition Number of GPRS UL TBF establishment failure due to Abis
congestion
Description The counter records the number of DB resource application
failure when attempting UL GPRS TBF establishment due to Abis
congestion.
Usage This counter is used to find out the number of DB resource
application failure when attempting UL GPRS TBF establishment
due to Abis congestion.

150 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

Measurement The counter accumulates at the following three time points:


Point
„ If PS control plane receives channel requests from MS on
CCCH and fails to apply for DB resource due to Abis
congestion, the counter increments. The measurement point
is A, as shown in Figure 76.

FIGURE 76 - DB RESOURCE REQUESTS FAILURE DUE TO ABIS CONGESTION


(CCCH)

„ If PS control panel receives channel requests from MS on


CCCH and fails to apply for DB resource due to Abis
congestion, the counter increments. The measurement point
is A, as shown in Figure 77.

FIGURE 77 - DB RESOURCE REQUESTS FAILURE DUE TO ABIS CONGESTION


(PCCCH)

„ If PS control panel receives UL assignment request messages


from PS user plane on CCCH and fails to apply for DB
resource due to Abis congestion, the counter increments. The
measurement point is A, as shown in Figure 78.

FIGURE 78 - DB RESOURCE REQUESTS FAILURE DUE TO ABIS CONGESTION


(DL GPRS TBF ALREADY ESTABLISHED)

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 151


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901190016
Definition Number of GPRS UL TBF establishment failure due to RR
congestion
Description The counter records the number of DB resource request failure
when attempting UL GPRS TBF establishment due to radio
resource congestion. There are three causes that lead to radio
resource congestion: MS per channel (MS number on each
channel reaches its maximum), no TAI/TFI and no PDCH
Usage This counter is used to find out the number of DB resource
application failure when attempting UL GPRS TBF establishment
due to RR congestion.
Measurement The counter accumulates at the following three time points:
Point
„ If PS control plane receives channel requests from MS on
CCCH and fails to apply for DB resource due to RR
congestion, the counter increments. The measurement point
is A, as shown in Figure 79.

FIGURE 79 - DB RESOURCE REQUESTS FAILURE DUE TO RR CONGESTION


(CCCH)

„ If PS control panel receives channel requests from MS on


CCCH and fails to apply for DB resource due to RR
congestion, the counter increments. The measurement point
is A, as shown in Figure 80.

FIGURE 80 - DB RESOURCE REQUESTS FAILURE DUE TO RR CONGESTION


(PCCCH)

„ If PS control panel receives UL assignment request messages


from PS user plane on CCCH and fails to apply for DB
resource due to RR congestion, the counter increments. The
measurement point is A, as shown in Figure 81.

152 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

FIGURE 81 - DB RESOURCE REQUESTS FAILURE DUE TO ABIS CONGESTION


(DL GPRS TBF ALREADY ESTABLISHED)

Unit Times

C901190017
Definition Number of GPRS UL TBF establishment failure due to UPPB-DSP
channel congestion
Description The counter records the number of DB resource application
failure when attempting UL GPRS TBF establishment due to
UPPB-DSP channel congestion.
Usage This counter is used to find out the number of DB resource
application failure when attempting UL GPRS TBF establishment
due to UPPB-DSP channel congestion.
Measurement The counter accumulates at the following three time points:
Point
„ If PS control plane receives channel requests from MS on
CCCH and fails to apply for DB resource due to UPPB-DSP
channel congestion, the counter increments. The
measurement point is A, as shown in Figure 82.

FIGURE 82 - DB RESOURCE REQUESTS FAILURE DUE TO UPPB-DSP


CHANNEL CONGESTION (CCCH)

„ If PS control panel receives channel requests from MS on


PCCCH and fails to apply for DB resource due to UPPB-DSP
channel congestion, the counter increments. The
measurement point is A, as shown in Figure 83.

Confidential and Proprietary Information of ZTE CORPORATION 153


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 83 - DB RESOURCE REQUESTS FAILURE DUE TO ABIS CONGESTION


(PCCCH)

„ If PS control panel receives UL assignment request messages


from PS user plane on CCCH (DL GPRS TBF already
established) and fails to apply for DB resource due to UPPB-
DSP congestion, the counter increments. The measurement
point is A, as shown in Figure 84.

FIGURE 84 - DB RESOURCE REQUESTS FAILURE DUE TO DPPB-DSP


CONGESTION (DL GPRS TBF ALREADY ESTABLISHED)

Unit Times

C901190018
Definition Number of GPRS UL TBF establishment channel allocate success
Description This counter counts the number of DB resource request
successes when attempting UL GPRS TBF establishment.
Usage This counter is used to find out the number of DB resource
request successes when attempting UL GPRS TBF establishment.
Measurement The counter accumulates at the following three time points:
Point
„ If PS control plane receives channel requests from MS on
CCCH and succeeds in applying for DB resource, the counter
increments. The measurement point is A, as shown in Figure
85.

154 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

FIGURE 85 - DB RESOURCE REQUEST SUCCESSES

„ If PS control panel receives channel requests from MS on


PCCCH and succeed in applying for DB resource, the counter
increments. The measurement point is A, as shown in Figure
86.

FIGURE 86 - DB RESOURCE REQUEST SUCCESSES

„ If only GPRS is supported in the network, PS control plane


receives EGPRS channel request on CCCH or on PCCCH from
MS, and DB resource request succeeds, the counter
increments.
Unit Times

C901190019
Definition Number of cell success for GPRS UL assignment due to ONE
PHASE access.
Description This counter counts the number of successful UL GPRS TBF
establishment due to one phase access.
Usage This counter is used to find out the number of UL GPRS TBF
establishment successes due to one phase access.
Measurement The counter accumulates at the following three time points:
Point
„ If PS control plane receives channel requests from MS on
CCCH due to one phase access and DB resource requests
succeeds, the counter increments. The measurement point is
A, as shown in Figure 87.

Confidential and Proprietary Information of ZTE CORPORATION 155


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 87 - CHANNEL REQUEST SUCCESSES ON CCCH DUE TO ONE PHASE


ACCESS

„ If BSC receives channel requests from MS on CCCH due to


one phase access, the counter increments. The measurement
point is A, as shown in Figure 88.

FIGURE 88 - PACKET CHANNEL REQUEST SUCCESSES ON CCCH DUE TO ONE


PHASE ACCESS

„ If only GPRS is supported in the network, PS control plane


receives EGPRS channel request on CCCH or on PCCCH from
MS, and DB resource request succeeds, the counter
increments.
Unit Times

C901190020
Definition Number of cell success for GPRS UL assignment due to single
block packet access
Description This counter counts the number of successful UL GPRS TBF
establishment due to single block packet access.
Usage This counter is used to find out the number of successful UL
GPRS TBF establishment due to single block packet access.
Measurement If PS control plane receives packet channel requests on PCCCH
Point from MS due to single block packet access and DB resource
request succeeds. The measurement point is A, as shown in
Figure 89.

156 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

FIGURE 89 - CHANNEL REQUESTS SUCCESSES DUE TO SINGLE BLOCK


P ACKET ACCESS

Unit Times

C901190021
Definition Number of cell success for GPRS UL assignment due to response
paging
Description This counter counts the number of successful UL GPRS TBF
establishment due to response paging.
Usage This counter is used to find out the number of packet channel
requests when MS attempting UL GPRS TBF establishment due
to response paging.
Measurement When PS control plane receives channel requests on PCCCH from
Point MS due to response paging and DB resource request succeeds,
the counter increments. The measurement point is A, as shown
in Figure 90.

FIGURE 90 - DB RESOURCE REQUEST SUCCESSES DUE TO RESPONSE P AGING

Unit Times

C901190022
Definition Number of cell success for GPRS UL assignment due to cell
updating
Description This counter counts the number of successful UL GPRS TBF
establishment due to cell update.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 157


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This counter is used to find out the number of successful UL


GPRS TBF establishment due to cell update.
Measurement When PS control plane receives channel requests on PCCCH from
Point MS duet to cell update and DB resource request succeeds, the
counter increments. The measurement point is A, as shown in
Figure 91.

FIGURE 91 - DB RESOURCE REQUEST SUCCESSES DUE TO CELL UPDATE

Unit Times

C901190023
Definition Number of cell success for GPRS UL assignment due to mobility
management.
Description The counter counts the number of successful UL GPRS TBF
establishment due to mobile management.
Usage This counter is used to find out the number of successful UL
GPRS TBF establishment due to mobile management.
Measurement If PS control plane receives channel requests on PCCCH from MS
Point due to mobile management and DB resource request succeeds,
the counter increments. The measurement point is A, as shown
in Figure 92.

FIGURE 92 - DB RESOURCE REQUEST SUCCESSES DUE TO MOBILE


MANAGEMENT (PCCCH)

Unit Times

158 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

C901190024
Definition Number of cell success for GPRS UL assignment due to TWO
PHASE access
Description This counter counts the number of successful UL GPRS TBF
establishment due to two phase access.
Usage This counter is used to find out the number of successful UL
GPRS TBF establishment due to two phase access.
Measurement The counter accumulates at the following two time points:
Point
„ If BSC receives channel requests from MS on CCCH due to
two phase access and DB resource request succeeds, the
counter increments. The measurement point is A, as shown
in Figure 93.

FIGURE 93 - DB RESOURCE REQUEST SUCCESSES DUE TO TWO PHASE


ACCESS (CCCH)

„ If BSC receives channel requests from MS on PCCCH due to


two phase access and DB resource request succeeds, the
counter increments. The measurement point is A, as shown
in Figure 94.

FIGURE 94 - DB RESOURCE REQUEST SUCCESSES ON PCCCH DUE TO TWO


PHASE ACCESS

Unit Times

C901190025
Definition

Confidential and Proprietary Information of ZTE CORPORATION 159


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Number of cell success for GPRS UL assignment due to short


access
Description This counter counts the number of successful UL GPRS TBF
establishment due to short access.
Usage This counter is used to find out the number of successful UL
GPRS TBF establishment due to short access.
Measurement The counter accumulates at the following two time points:
Point
„ If BSC receives channel requests from MS on CCCH due to
short access and DB resource request succeeds, the counter
increments. The measurement point is A, as shown in Figure
95.

FI G U R E 9 5 - DB R E S O U R C E R E Q U E S T S U CC E S S E S D U E TO S H O R T AC C E S S
(PCCCH)

„ If only GPRS is supported in the network, PS control plane


receives EGPRS channel request on CCCH or on PCCCH from
MS, and DB resource request succeeds, the counter
increments.
Unit Times

C901190026
Definition Number of allocated PDCH for GPRS UL TBF establishment
Description This counter counts the number of successfully assigned PDTCH
when UL GPRS TBF successfully established.
Usage This counter is used to find out the number of successfully
assigned PDTCH when UL GPRS TBF successfully established.
Measurement The counter accumulates at the following three time points:
Point
„ When PS control plane receives channel requests on CCCH
from MS and DB resource requests succeed, the counter
increments. The measurement point is A, as shown in Figure
95.
„ When PS control plane receives packet channel requests on
PCCCH from MS, the counter increments. The measurement
point is A, as shown in Figure 96.
„ If only GPRS is supported in the network, PS control plane
receives EGPRS channel request on CCCH or on PCCCH from

160 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

MS, and DB resource request succeeds, the counter


increments.
Unit Times

C901190027
Definition Number of GPRS UL TBF establishment failure due to channel
activate failed
Description This counter counts the number of PDTCH activate failure when
establishing UL GPRS TBF.
Usage This counter is used to find out the number of PDTCH activate
failure when establishing UL GPRS TBF (including initially
establish UL TBF and establish UL TBF when DL TBF exists).
Measurement The counter accumulates at the following two time points:
Point
„ When BSC receives PDTCH channel activate failure message
reported by BTS, the counter increments. The measurement
point is A, as shown in Figure 38.
„ When “wait for PDTCH channel activation and connection
response” counter times out and BSC fails to receive PDTCH
activate response message reported by BTS, this counter
increments.
Unit Times

C901190028
Definition Number of GPRS UL TBF establishment failure due to BTS
connection failed
Description This counter counts the number of failure to establish UL GPRS
TBF due to BTS connection failure.
Usage This counter is used to find out the number of UL GPRS TBF
establishment failure (including initially establish UL TBF and
establish UL TBF when DL TBF exists) due to BTS connection
failure.
Measurement The counter accumulates at the following two time points:
Point
„ When PS control plane receives connection failure message
reported by connection module due to BTS connection failure,
the counter increments. The measurement point is A, as
shown in Figure 39.
„ When “wait for PDTCH channel activate and connection
response” counter times out and BSC fails to receive
connection success response message reported by
connection module, this counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 161


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901190029
Definition Number of GPRS UL TBF establishment failure due to BIU
connection failed
Description This counter counts the number of failure to establish UL GPRS
TBF due to BIU connection failure.
Usage This counter is used to find out the number of UL GPRS TBF
establishment failure (including initially establish UL TBF and
establish UL TBF when DL TBF exists) due to BIU connection
failure.
Measurement When PS control plane receives connection failure message
Point reported by connection modules due to BIU connection failure,
the counter increments. The measurement point is A, as shown
in Figure 40.
Unit Times

C901190030
Definition Number of GPRS UL TBF channel activate establishment success
Description This counter counts the number of channel activate and
connection successes when establishing UL GPRS TBF.
Usage This counter is used to find out the number of channel activate
and connection successes when establishing UL GPRS TBF.
Measurement When PS control plane receives channel activate response
Point message reported by BTS and connection successes
acknowledgement message reported by connection module, the
counter increments. The measurement point is A, as shown in
Figure 49.
Unit Times

C901190031
Definition Number of GPRS UL TBF establishment failure due to not receive
PIA
Description This counter counts the number of failure to send immediate
assignment message to MS when establishing UL GPRS TBF.
Usage This counter is used to find out the number of failure to send
immediate assignment message to MS when establishing UL
GPRS TBF.
Measurement The counter accumulates at the following two time points:
Point
„ When PS control plane receives immediate assignment
failure message reported by BTS, the counter increments.

162 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

„ When “wait for immediate assignment and sending


indication” counter times out and BSC fails to receive
immediate assignment and sending indication message, the
counter increments.
Unit Times

C901190032
Definition Number of GPRS UL TBF establishment failure on PCCCH/CCCH
due to UPPB-DSP congestion
Description This counter counts the number of failure to establish UL GPRS
TBF.
Usage This counter is used to find out the number of failure to establish
UL GPRS TBF.
Measurement When PS control plane assigns single block through two phase
Point access from PS user plane, or gets access to PS user plane
through one phase access and starts assignment timer. If the
timer times out, resource request from PS user plane (two phase
access) is not received or indication (one phase access) is not
established, the counter increments. The measurement point is
A, as shown in Figure 96

FIGURE 96 - UL GPRS TBF ESTABLISHMENT ON PCCCH/CCCH

Unit Times

C901190033
Definition Number of GPRS UL TBF establishment failure on PACCH due to
UPPB-DSP congestion
Description This counter is not used currently.

C901190034
Definition Number of GPRS UL TBF establishment success on PCCCH/CCCH

Confidential and Proprietary Information of ZTE CORPORATION 163


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Description This counter counts the number of successful UL GPRS TBF


establishment and receiving MS TLL1.
Usage This counter is used to find out the number of successful UL
GPRS TBF establishment and receiving MS TLL1.
Measurement The counter accumulates at the following two time points:
Point
„ When PS control plane receives MS TLL1 “MAC establishment
indication” message reported by PS user plane in the
premise of one phase access, the counter increments. The
measurement point is A, as shown in Figure 97.

FIGURE 97 - UL ONE-PHASE- ACCESS RESOURCE ASSIGNMENT SUCCESSES

„ PS control plane receives resource request message from PS


user plane in the premise of two phase access, the counter
increments. The measurement point is A, as shown in Figure
98.

FIGURE 98 - UL TWO-PHASE- ACCESS SINGLE BLOCK ASSIGNMENT


SUCCESSES

Unit Times

C901190035
Definition Number of GPRS UL TBF establishment success on PACCH
Description This counter is not used currently.

C901190038
Definition Number of GPRS UL TBF resource reallocation failure due to Abis
congestion for DL TBF establishment

164 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

Description In the situation when UL GPRS TBF is already established, DL


TBF is needed to be established on PACCH; DB resource request
fails which leads to UL resource reallocation failure. The counter
records the number of UL resource reallocation failure due to
Abis resource congestion.
Usage This counter is used to find out the number of UL GPRS TBF
reallocation failure due to Abis congestion.
Measurement In the situation when UL GPRS TBF is established, PS control
Point plane receives DL assignment request message from PS user
plane, and DB resource request fails due to Abis congestion, the
counter increments. The measurement point is A, as shown in
Figure 32.
Unit Times

C901190039
Definition Number of GPRS UL TBF resource reallocation failure due to RR
congestion for DL TBF establishment
Description In the situation when UL GPRS TBF is already established, DL
TBF is needed to be established on PACCH; DB resource request
fails which leads to UL resource reallocation failure. The counter
records the number of UL resource reallocation failure due to
Abis resource congestion.
There are three causes which lead to radio resource congestion:
MS per channel (MS number per channel reaches its maximum),
TAI/TFI (no TAI or TFI available) and no PDCH available.
Usage This counter is used to find out the number of UL GPRS TBF
reallocation failure due to RR congestion.
Measurement In the situation when UL GPRS TBF is established, PS control
Point plane receives DL assignment request message from PS user
plane, and DB resource request fails due to RR congestion, the
counter increments. The measurement point is A, as shown in
Figure 34.
Unit Times

C901190040
Definition Number of GPRS UL TBF resource reallocation failure due to
UPPB-DSP channel congestion for DL TBF establishment
Description In the situation when UL GPRS TBF is already established, DL
TBF is needed to be established on PACCH; DB resource request
fails which leads to UL resource reallocation failure. The counter
records the number of UL resource reallocation failure due to
UPPB-DSP channel resource congestion.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 165


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This counter is used to find out the number of UL GPRS TBF


reallocation failure due to UPPB-DSP channel congestion.
Measurement In the situation when UL GPRS TBF is established, PS control
Point plane receives DL assignment request message from PS user
plane, and DB resource request fails due to UPPB-DSP channel
congestion, the counter increments. The measurement point is A,
as shown in Figure 36.
Unit Times

C901190041
Definition Number of GPRS UL TBF resource reallocation success due to DL
TBF establishment
Description The counter records the number of successful DL TBF
establishment on PACCH when UL GPRS TBF is already
established.
Usage This counter is used to find out the number of DL GPRS TBF
reallocation successes.
Measurement In the situation when UL GPRS TBF is established, PS control
Point plane receives DL assignment request message from PS user
plane, and DB resource request succeeds, the counter
increments. The measurement point is A, as shown in Figure 37.
Unit Times

C901190042
Definition Number of allocated PDCH for GPRS UL TBF resource reallocation
due to DL TBF establishment
Description The counter records the number of successful allocated PDTCH
when UL GPRS TBF is successfully reallocated.
Usage This counter is used to find out the number of successful
allocated PDTCH when UL GPRS TBF is successfully reallocated.
Measurement In the situation when UL GPRS TBF is established, PS control
Point plane receives DL assignment request message from PS user
plane, and DB resource request succeeds, the counter
increments. The measurement point is A, as shown in Figure 37.
Unit Times

C901190043
Definition Number of GPRS UL TBF resource reallocation failure due to
channel activate failure for DL TBF establishment

166 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

Description The counter records the number of PDTCH activate failure during
UL GPRS TBF resource reallocation.
Usage This counter is used to find out the number of PDTCH activate
failure during UL GPRS TBF resource reallocation.
Measurement The counter accumulates at the following two time points:
Point
„ When BSC receives PDTCH channel activate failure message
from BTS, the counter increments. The measurement point is
A, as shown in Figure 38.
„ When “Wait for PDTCH channel activation and connection
response” timer times out, and BSC fails to receive PDTCH
channel activate response message from BTS, the counter
increments.
Unit Times

C901190044
Definition Number of GPRS UL TBF resource reallocation failure due to BTS
connection failure for DL TBF establishment
Description The counter records the number of BTS connection failure during
UL GPRS TBF resource reallocation.
Usage This counter is used to find out the number of BTS connection
failure during UL GPRS TBF resource reallocation.
Measurement The counter accumulates at the following two time points:
Point
„ When PS control plane receives connection failure message
from connection module due to BTS connection failure, the
counter increments. The measurement point is A, as shown
in Figure 39.
„ When “Wait for PDTCH channel activation and connection
response” timer times out, and BSC fails to receive
connection success message from connection module, the
counter increments.
Unit Times

C901190045
Definition Number of GPRS UL TBF resource reallocation failure due to BIU
connection failure for DL TBF establishment
Description The counter records the number of BIU connection failure during
UL GPRS TBF resource reallocation.
Usage This counter is used to find out the number of BIU connection
failure during UL GPRS TBF resource reallocation.

Confidential and Proprietary Information of ZTE CORPORATION 167


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Measurement When PS control plane receives connection failure message from


Point connection module due to BIU connection failure, the counter
increments. The measurement point is A, as shown in Figure 40.
Unit Times

C901190046
Definition Number of GPRS UL TBF resource reallocation success of channel
activate for DL TBF establishment
Description The counter records the number of channel activate and
connection successes during UL GPRS TBF resource reallocation.
Usage This counter is used to find out the number of channel activate
and connection successes during UL GPRS TBF resource
reallocation.
Measurement When PS control plane receives channel activate ack message
Point and connection success ack message from connection module
due to BIU connection failure, the counter increments. The
measurement point is A, as shown in Figure 49.
Unit Times

C901190047
Definition Number of GPRS UL TBF resource reallocation failure due to DL
TBF establishment.
Description The counter is not used currently.

C901190048
Definition Number of GPRS UL TBF resource reallocation success due to DL
TBF establishment.
Description The counter is not used currently.

C901190051
Definition Number of GPRS UL TBF resource reallocation failure due to Abis
congestion for LLC transmission
Description During UL EGPRS TBF transmission process, PS user plane sends
resource reallocation message to PS control plane due to LLC
frame change; PS control plane requests DB resource after
receiving the message. The counter records the number of DB
resource request failure due to Abis resource congestion after PS

168 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

control plane receiving resource reallocation request during UL


EGPRS TBF transmission process.
Usage This counter is used to find out DB resource request failure due
to Abis resource congestion after PS control plane receiving
resource reallocation request during UL EGPRS TBF transmission
process.
Measurement When PS control plane receives resource reallocation message
Point from PS user plane, and DB resource request fails due to Abis
congestion, the counter increments. The measurement point is A,
as shown in Figure 50.
Unit Times

C901190052
Definition Number of GPRS UL TBF resource reallocation failure due to RR
congestion for LLC transmission
Description During UL EGPRS TBF transmission process, PS user plane sends
resource reallocation message to PS control plane due to LLC
frame change; PS control plane requests DB resource after
receiving the message. The counter records the number of DB
resource request failure due to radio resource congestion after
PS control plane receiving resource reallocation request during
UL EGPRS TBF transmission process.
There are three causes leading to RR congestion: MS per
channel (reaches its maximum), TAI/TFI (not available), and no
PDTCH.
Usage This counter is used to find out DB resource request failure due
to RR congestion after PS control plane receiving resource
reallocation request during UL EGPRS TBF transmission process.
Measurement When PS control plane receives resource reallocation message
Point from PS user plane, and DB resource request fails due to RR
congestion, the counter increments. The measurement point is A,
as shown in Figure 51.
Unit Times

C901190053
Definition Number of GPRS UL TBF resource reallocation failure due to
UPPB-DSP channel congestion for LLC transmission
Description During UL EGPRS TBF transmission process, PS user plane sends
resource reallocation message to PS control plane due to LLC
frame change; PS control plane requests DB resource after
receiving the message. The counter records the number of DB
resource request failure due to UPPB-DSP channel congestion

Confidential and Proprietary Information of ZTE CORPORATION 169


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

after PS control plane receiving resource reallocation request


during UL EGPRS TBF transmission process.
Usage This counter is used to find out DB resource request failure due
to UPPB-DSP channel congestion after PS control plane receiving
resource reallocation request during UL EGPRS TBF transmission
process.
Measurement When PS control plane receives resource reallocation message
Point from PS user plane, and DB resource request fails due to UPPB-
DSP channel congestion, the counter increments. The
measurement point is A, as shown in Figure 52.
Unit Times

C901190054
Definition Number of GPRS UL TBF resource reallocation success due to
LLC transmission
Description During UL EGPRS TBF transmission process, PS user plane sends
resource reallocation message to PS control plane due to LLC
frame change; PS control plane requests DB resource after
receiving the message. The counter records the number of DB
resource request successes after PS control plane receiving
resource reallocation request during UL EGPRS TBF transmission
process.
Usage This counter is used to find out DB resource request success due
after PS control plane receiving resource reallocation request
during UL EGPRS TBF transmission process.
Measurement When PS control plane receives resource reallocation message
Point from PS user plane, and DB resource request succeeds, the
counter increments. The measurement point is A, as shown in
Figure 53.
Unit Times

C901190055
Definition Number of allocated PDCH for GPRS UL TBF resource reallocation
due to LLC transmission.
Description During UL EGPRS TBF transmission process, PS user plane sends
resource reallocation message to PS control plane due to LLC
frame change; PS control plane requests DB resource after
receiving the message. The counter records the number of
successfully allocated PDTCH after PS control plane receiving
resource reallocation requests during UL GPRS TBF.
Usage This counter is used to find out the number of successful
allocated PDTCH when UL GPRS TBF is successfully reallocated.

170 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

Measurement When PS control plane receives resource reallocation message


Point from PS user plane, and DB resource request succeeds, the
counter increments. The measurement point is A, as shown in
Figure 53.
Unit Times

C901190056
Definition Number of GPRS UL TBF resource reallocation failure due to
channel activate failure for DL TBF establishment
Description The counter records the number of PDTCH activate failure after
BSC receiving resource reallocation request during UL GPRS TBF
resource reallocation.
Usage This counter is used to find out the number of PDTCH activate
failure during UL GPRS TBF resource reallocation.
Measurement The counter accumulates at the following two time points:
Point
„ When BSC receives PDTCH channel activate failure message
from BTS, the counter increments. The measurement point is
A, as shown in Figure 38.
„ When “Wait for PDTCH channel activation and connection
response” timer times out, and BSC fails to receive PDTCH
channel activate response message from BTS, the counter
increments.
Unit Times

C901190057
Definition Number of GPRS UL TBF resource reallocation failure due to BTS
connection failure for LLC transmission
Description The counter records the number of connection failure due to BTS
connection failure after BSC receiving resource reallocation
request during UL GPRS TBF transmission.
Usage This counter is used to find out the number of BTS connection
failure during UL GPRS TBF resource transmission.
Measurement The counter accumulates at the following two time points:
Point
„ When PS control plane receives connection failure message
from connection module due to BTS connection failure, the
counter increments. The measurement point is A, as shown
in Figure 39.
„ When “Wait for PDTCH channel activation and connection
response” timer times out, and BSC fails to receive
connection success message from connection module, the
counter increments.

Confidential and Proprietary Information of ZTE CORPORATION 171


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Unit Times

C901190058
Definition Number of GPRS UL TBF resource reallocation failure due to BIU
connection failure for LLC transmission
Description The counter records the number of BIU connection failure during
UL GPRS TBF transmission.
Usage This counter is used to find out the number of BIU connection
failure during UL GPRS TBF transmission.
Measurement When PS control plane receives connection failure message from
Point connection module due to BIU connection failure, the counter
increments. The measurement point is A, as shown in Figure 40.
Unit Times

C901190059
Definition Number of GPRS UL TBF resource reallocation success of channel
activate for LLC transmission
Description The counter records the number of channel activate and
connection successes during UL GPRS TBF transmission.
Usage This counter is used to find out the number of channel activate
and connection successes during UL GPRS TBF tranmission.
Measurement When PS control plane receives channel activate ack message
Point and connection success ack message from connection module
due to BIU connection failure, the counter increments. The
measurement point is A, as shown in Figure 49.
Unit Times

C901190060
Definition Number of GPRS UL TBF resource reallocation failure due to LLC
transmission.
Description The counter is not used currently.

C901190061
Definition Number of GPRS UL TBF resource reallocation success due to
LLC transmission.
Description The counter is not used currently.

172 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

C901190062
Definition Number of GPRS UL TBF resource reallocation requests for
resource request
Description The counter is not used currently.

C901190064
Definition Number of GPRS UL TBF resource reallocation failure due to Abis
congestion for resource request
Description The counter records the number of DB resource request failure
due to Abis congestion after PS control plane resource request
from MS during UL GPRS TBF.
Usage This counter is used to find out the number of DB resource
request failure after PS control plane receives resource request
from MS during UL GPRS TBF process (including UL two-phase
access and UL TBF transmission).
Measurement PS control plane receives resource request message from PS
Point user plane, and DB resource request fails due to Abis congestion,
the counter increments. The measurement point is A, as shown
in Figure 99.

FIGURE 99 - DB RESOURCE REQUESTS FAILURE DUE TO ABIS CONGESTION


(RESOURCE REQUEST)

PS User PS Control
DB
Plane Plane

Resource Request
Message Resource
Request

Resource request fail due to


Abis congestion

Unit Times

C901190065
Definition Number of GPRS UL TBF resource reallocation failure due to RR
congestion for resource request
Description The counter records the number of DB resource request failure
after PS control plane receives resource request from MS due to
RR congestion during UL GPRS TBF.

Confidential and Proprietary Information of ZTE CORPORATION 173


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

There are three cause leading to radio resource congestion: MS


per channel (MS number per channel reaches its maximum),
TAI/TFI (no TAI/TFI available), no PDCH (no PS service channel
available)
Usage This counter is used to find out the number of DB resource
request failure after PS control plane receives resource request
from MS due to RR congestion during UL GPRS TBF process
(including UL two-phase access and UL TBF transmission).
Measurement PS control plane receives resource request message from PS
Point user plane, and DB resource request fails due to RR congestion,
the counter increments. The measurement point is A, as shown
in Figure 100.

FIGURE 100 - DB RESOURCE REQUESTS FAILURE DUE TO RR CONGESTION (2)

Unit Times

C901190066
Definition Number of GPRS UL TBF resource reallocation failure due to
UPPB-DSP channel congestion for resource request
Description The counter records the number of DB resource request failure
after PS control plane receives resource request from MS due to
UPPB-DSP channel congestion during UL GPRS TBF.
Usage This counter is used to find out the number of DB resource
request failure after PS control plane receives resource request
from MS due to UPPB-DSP channel congestion during UL GPRS
TBF process (including UL two-phase access and UL TBF
transmission).
Measurement PS control plane receives resource request message from PS
Point user plane, and DB resource request fails due to RR congestion,
the counter increments. The measurement point is A, as shown
in Figure 101.

174 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

FIGURE 101 - DB RESOURCE REQUESTS FAILURE DUE TO UPPB-DSP


CHANNEL CONGESTION (RESOURCE REQUEST)

PS User PS Control
DB
Plane Plane

Resource Request
Resource
Request

Resource request fail due to


UPPB-DSP channel congestion

Unit Times

C901190067
Definition Number of GPRS UL TBF resource reallocation success due to
resource request
Description The counter records the number of successful DB resource
request after PS control plane receives resource request
message from MS during UL GPRS TBF process.
Usage This counter is used to find out the number of DB resource
request successes after PS control plane receives resource
request from MS during UL GPRS TBF process (including UL two-
phase access and UL TBF transmission).
Measurement PS control plane receives resource request message from PS
Point user plane, and DB resource request succeeds, the counter
increments. The measurement point is A, as shown in Figure 102.

FIGURE 102 - DB RESOURCE REQUESTS SUCCESSES (RESOURCE REQUEST)

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 175


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901190068
Definition Number of allocated PDTCH for GPRS UL TBF resource
reallocation due to resource request
Description The counter records the number of successful allocated PDTCH
after PS control plane receives resource request message from
MS during UL GPRS TBF process.
Usage This counter is used to find out the number of successful
allocated PDTCH after PS control plane receives resource request
from MS during UL GPRS TBF process (including UL two-phase
access and UL TBF transmission).
Measurement PS control plane receives resource request message from PS
Point user plane, and DB resource request succeeds, the counter
increments. The measurement point is A, as shown in Figure 103.

FIGURE 103 - DB RESOURCE REQUESTS SUCCESSES (RESOURCE REQUEST)

Unit Times

C901190069
Definition Number of GPRS UL TBF resource reallocation failure due to
channel activate failure for resource request
Description The counter records the number of PDTCH activate failure during
UL GPRS TBF resource reallocation after PS control plane
receives resource request message.
Usage The counter records the number of PDTCH activate failure during
UL GPRS TBF resource reallocation after PS control plane
receives resource request message in UL GPRS TBF
process(including UL two-phase access and one-phase TBF
transmission).
Measurement The counter accumulates at the following two time points:
Point
„ When BSC receives PDTCH channel activate failure message
from BTS, the counter increments. The measurement point is
A, as shown in Figure 38.

176 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

„ When “Wait for PDTCH channel activation and connection


response” timer times out, and BSC fails to receive PDTCH
channel activate response message from BTS, the counter
increments.
Unit Times

C901190070
Definition Number of GPRS UL TBF resource reallocation failure due to BTS
connection failure for resource request
Description The counter records the number of connection failure due to BTS
connection failure during UL GPRS TBF resource reallocation
after PS control plane receives resource request message.
Usage The counter records the number of connection failure due to BTS
connection failure during UL GPRS TBF resource reallocation
after PS control plane receives resource request message in UL
GPRS TBF process (including UL two-phase access and one-
phase TBF transmission).
Measurement The counter accumulates at the following two time points:
Point
„ When PS control plane receives connection failure message
from connection module due to BTS connection failure, the
counter increments. The measurement point is A, as shown
in Figure 39.
„ When “Wait for PDTCH channel activation and connection
response” timer times out, and BSC fails to receive
connection success message from connection module, the
counter increments.
Unit Times

C901190071
Definition Number of GPRS UL TBF resource reallocation failure due to BIU
connection failure for resource request
Description The counter records the number of connection failure due to BIU
connection failure during UL GPRS TBF resource reallocation
after PS control plane receives resource request message.
Usage The counter records the number of connection failure due to BIU
connection failure during UL GPRS TBF resource reallocation
after PS control plane receives resource request message in UL
GPRS TBF process (including UL two-phase access and one-
phase TBF transmission).
Measurement When PS control plane receives connection failure message from
Point connection module due to BIU connection failure, the counter
increments. The measurement point is A, as shown in Figure 40.

Confidential and Proprietary Information of ZTE CORPORATION 177


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Unit Times

C901190072
Definition Number of GPRS UL TBF resource reallocation success of channel
activate for resource request
Description The counter records the number of channel activate and
connection successes during UL GPRS TBF resource reallocation
after PS control plane receives resource request message.
Usage The counter records the number of channel activate and
connection failure during UL GPRS TBF resource reallocation
after PS control plane receives resource request message in UL
GPRS TBF process (including UL two-phase access and one-
phase TBF transmission).
Measurement When PS control plane receives channel activate ack message
Point and connection success ack message from connection module
due to BIU connection failure, the counter increments. The
measurement point is A, as shown in Figure 49.
Unit Times

C901190073
Definition Number of GPRS UL TBF resource reallocation failure due to
resource request.
Description The counter is not used currently.

C901190074
Definition Number of GPRS UL TBF resource reallocation success due to
resource request
Description The counter is not used currently.

C901190075
Definition Number of GPRS UL TBF release due to flush LL
Description This counter counts the number of UL GPRS TBF release after PS
control plane receiving request due to flush LL.
Usage This counter is used to find out the number of UL GPRS TBF
release after PS control plane receiving request due to flush LL.
Measurement When PS control plane of BSC receives FLUSH message from
Point SGSN and release is executed when UL GPRS TBF is established,

178 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

the counter increments. The measurement point is A, as shown


in Figure 54.
Unit Times

C901190076
Definition Number of GPRS UL TBF release due to GPRS suspend requests
Description This counter counts the number of UL GPRS TBF release after PS
control plane receiving request due to GPRS suspend requests.
Usage This counter is used to find out the number of UL GPRS TBF
release due to GPRS suspend requests.
Measurement When PS control plane of BSC receives SUSPEND message from
Point SGSN and release is executed when UL GPRS TBF is established,
the counter increments. The measurement point is A, as shown
in Figure 55.
Unit Times

C901190077
Definition Number of GPRS UL TBF forcing release by CS
Description This counter counts the number of UL GPRS TBF forcing release
by CS.
Usage This counter is used to find out the number of UL GPRS TBF
forcing release by CS..
Measurement When PS control plane of BSC receives PDCH RELEASE message
Point from CS control plane when UL GPRS TBF is established, the
counter increments. The measurement point is A, as shown in
Figure 56.
Unit Times

C901190078
Definition Number of GPRS UL TBF normal release due to user plane
requests.
Description This counter counts the number of UL GPRS TBF normal release
due to user plane requests.
Usage This counter is used to find out the number of UL GPRS TBF
normal release due to user plane requests.
Measurement When PS control plane of BSC receives NORMAL RELEASE
Point REQUEST message from PS user plane when UL GPRS TBF exists,
the counter increments. The measurement point is A, as shown
in Figure 57.

Confidential and Proprietary Information of ZTE CORPORATION 179


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Unit Times

C901190079
Definition Number of GPRS UL TBF abnormal release due to user plane
requests
Description This counter counts the number of UL GPRS TBF abnormal
release due to user plane requests.
Usage This counter is used to find out the number of UL GPRS TBF
abnormal release due to user plane requests.
Measurement When PS control plane receives ABNORMAL RELEASE REQUEST
Point message from PS user plane when UL GPRS TBF exists, the
counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C901190080
Definition Number of GPRS UL TBF release due to NSVC unavailability
Description This counter counts the number of UL EGPRS TBF release due to
NSVC unavailability.
Usage This counter is used to find out the number of UL EGPRS TBF
release after receiving forcing release request due to NSVC
unavailability
Measurement When PS control plane receives NSVC unavailability command to
Point release PS control plane module from DB when UL GPRS TBF
exists, the counter increments. The measurement point is A, as
shown in Figure 59.
Unit Times

C901190081
Definition Number of GPRS UL TBF release due to BVC unavailability
Description This counter counts the number of UL GPRS TBF release due to
BVC unavailability.
Usage This counter is used to find out the number of UL GPRS TBF
release after receiving forcing release request due to BVC
unavailability
Measurement When PS control plane receives BVC unavailability command to
Point release PS control plane module from DB when UL GPRS TBF
exists, the counter increments. The measurement point is A, as
shown in Figure 60.

180 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

Unit Times

C901190082
Definition Number of GPRS UL TBF release due to other reasons.
Description This counter counts the number of UL EGPRS TBF forcing release
due to other reasons.
Usage This counter is used to find out the number of UL EGPRS TBF
release after receiving forcing release request due to other
reasons.
Measurement When PS control plane receives release message due to other
Point reasons when UL GPRS TBF exists, the counter increments. The
measurement point is A, as shown in Figure 64.
Unit Times

C901190083
Definition Number of UL GPRS TBF grab resources
Description This counter counts the number of UL GPRS TBF grab resources.
Usage This counter is used to find out the frequency for UL GPRS TBF
grabbing other TBF
Measurement This counter increments while UL GPRS TBF is established during
Point resource adjustment, resource request is successful, and other
TBF resource is grabbed. Measurement point is A as shown in
Figure 104.

FIGURE 104 - UL GPRS RESOURCE REQUEST SUCCESS

PS控制面 数据库
申请资源(上行 GPRS)

申请资源成功

Unit Times

C901190084
Definition Number of grab instance by UL GPRS TBF
Description This counter counts the number of grab instance by UL GPRS
TBF.

Confidential and Proprietary Information of ZTE CORPORATION 181


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Usage This counter is used to find out the frequency for UL GPRS TBF
grabbing other TBF resource.
Measurement This counter increments while UL GPRS TBF is established during
Point resource adjustment, resource request is successful, and other
TBF resource is grabbed. Measurement point is A as shown in
Figure 104.
Unit Times

C901190085
Definition Number of UL GPRS TBF queuing
Description This counter counts the number of UL GPRS TBF queuing.
Usage This counter is used to find out the frequency for UL GPRS TBF
queuing.
Measurement This counter increments while UL GPRS TBF is established during
Point resource adjustment, resource request is successful but queuing
is required due to incompliant to QoS rate. Measurement point is
A as shown in Figure 104.
Unit Times

C901190086
Definition Number of UL GPRS TBF queuing success
Description This counter counts the number of UL GPRS TBF queuing success.
Usage This counter is used to find out the frequency for UL GPRS TBF queuing
success.
Measurement This counter increments while UL GPRS TBF is established during
Point resource adjustment, the instance to be queued successfully assigns
resource for user plane, and database is successfully registered.
Measurement point is A as shown in Figure 105.

FIGURE 105 - RESOURCE ASSIGNMENT SUCCESS

PS control plane
PS控制面 PS user plane
PS用户面
Resource
Instance needs 资源指派
assignment
实例需要
queue,
排队,注
registration
success
册成功
A

Unit Times

182 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Uplink GPRS Data TBF Statistics

C901190087
Definition Number of UL GPRS TBF release TBF during queuing
Description This counter counts the number of UL GPRS TBF release during
queuing.
Usage This counter is used to find out the frequency for UL GPRS TBF
release during queuing.
Measurement This counter increments while UL GPRS TBF is released and
Point instance still in queuing state. The measurement point is A as
shown in Figure 106.

FIGURE 106 - RELEASE UL GPRS TBF

PS PS控制面
control plane

Release UL GPRS TBF,


释放上行GPRS
instance still in TBF,
queuing
实例仍在排队
A

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 183


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This page is intentionally blank.

184 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8

Uplink EGPRS Data TBF


Statistics

UL EGPRS data TBF statistics collects information about the


process of establishment and release of UL EGPRS TBF (cell).
This chapter contains detailed information about counters
related to UL GPRS data TBF statistic.

Overview
UL GPRS data TBF statistics collects the information about the
establishment, maintain and release of UL GPRS TBF. The
statistic unit is cell.

UL GPRS Data TBF Statistics


Counter Index
Table 12 lists counters related to UL GPRS data TBF statistic.

TABLE 12 - UL EGPRS DATA TBF STATISTICS COUNTER

Counter ID What It Counts


Number of GPRS UL TBF establishment
C901200002
requests on CCCH
Number of EGPRS UL TBF establishment
C901200003
requests on CCCH
Number of GPRS UL TBF establishment
C901200004
requests on PCCCH
Number of EGPRS UL TBF establishment
C901200005
requests on PCCCH
Number of GPRS UL TBF establishment
C901200006
requests on PACCH

Confidential and Proprietary Information of ZTE CORPORATION 185


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


Number of cell attempts for UL assignment
C901200007
due to ONE PHASE access
Number of cell attempts for UL assignment
C901200008
due to single block packet access
Number of cell attempts for UL assignment
C901200009
due to response paging

Number of cell attempts for UL assignment


C901200010
due to cell updating

Number of cell attempts for UL assignment


C901200011
due to mobility management

Number of cell attempts for UL assignment


C901200012
due to TWO PHASE access

Number of cell attempts for UL assignment


C901200013
due to short access

Number of EGPRS UL TBF establishment


C901200015 failure due to Abis congestion

Number of EGPRS UL TBF establishment


C901200016 failure due to RR congestion

Number of EGPRS UL TBF establishment


C901200017 failure due to UPPB-DSP channel
congestion
Number of EGPRS UL TBF establishment
C901200018 channel allocate success

Number of cell success for EGPRS UL


C901200019
assignment due to ONE PHASE access

Number of cell success for EGPRS UL


C901200020 assignment due to single block packet
access

Number of cell success for EGPRS UL


C901200021
assignment due to response paging

Number of cell success for EGPRS UL


C901200022
assignment due to cell updating

Number of cell success for EGPRS UL


C901200023
assignment due to mobility management

Number of cell success for EGPRS UL


C901200024
assignment due to TWO PHASE access

Number of cell success for EGPRS UL


C901200025
assignment due to short access

186 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

Counter ID What It Counts


Number of allocated PDCH for EGPRS UL
C901200026 TBF establishment

Number of EGPRS UL TBF establishment


C901200027 failure due to channel activate failed

Number of EGPRS UL TBF establishment


C901200028 failure due to BTS connection failed

Number of EGPRS UL TBF establishment


C901200029 failure due to BIU connection failed

Number of EGPRS UL TBF channel activate


C901200030 establishment success

Number of EGPRS UL TBF establishment


C901200031 failure due to not receive PIA

Number of EGPRS UL TBF establishment


C901200032 failure on PCCCH/CCCH due to UPPB-DSP
congestion
Number of EGPRS UL TBF establishment
C901200033 failure on PACCH due to UPPB-DSP
congestion
Number of EGPRS UL TBF establishment
C901200034 success on PCCCH/CCCH

Number of EGPRS UL TBF establishment


C901200035 success on PACCH

Number of EGPRS UL TBF resource


C901200038 reallocation failure due to Abis congestion
for DL TBF establishment
Number of EGPRS UL TBF resource
C901200039 reallocation failure due to RR congestion
for DL TBF establishment
Number of EGPRS UL TBF resource
reallocation failure due to UPPB-DSP
C901200040
channel congestion for DL TBF
establishment
Number of EGPRS UL TBF resource
C901200041 reallocation success due to DL TBF
establishment
Number of allocated PDCH for EGPRS UL
C901200042 TBF resource reallocation due to DL TBF
establishment
Number of EGPRS UL TBF resource
C901200043 reallocation failure due to channel activate
failure for DL TBF establishment
Number of EGPRS UL TBF resource
C901200044 reallocation failure due to BTS connection
failure for DL TBF establishment

Confidential and Proprietary Information of ZTE CORPORATION 187


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


Number of EGPRS UL TBF resource
C901200045 reallocation failure due to BIU connection
failure for DL TBF establishment
Number of EGPRS UL TBF resource
C901200046 reallocation success of channel activate for
DL TBF establishment
Number of EGPRS UL TBF resource
C901200047 reallocation failure due to DL TBF
establishment
Number of EGPRS UL TBF resource
C901200048 reallocation success due to DL TBF
establishment
Number of EGPRS UL TBF resource
C901200051 reallocation failure due to Abis congestion
for LLC transmission
Number of EGPRS UL TBF resource
C901200052 reallocation failure due to RR congestion
for LLC transmission
Number of EGPRS UL TBF resource
C901200053 reallocation failure due to UPPB-DSP
channel congestion for LLC transmission
Number of EGPRS UL TBF resource
C901200054 reallocation success due to LLC
transmission
Number of allocated PDCH for EGPRS UL
C901200055 TBF resource reallocation due to LLC
transmission
Number of EGPRS UL TBF resource
C901200056 reallocation failure due to channel activate
failure for LLC transmission
Number of EGPRS UL TBF resource
C901200057 reallocation failure due to BTS connection
failure for LLC transmission
Number of EGPRS UL TBF resource
C901200058 reallocation failure due to BIU connection
failure for LLC transmission
Number of EGPRS UL TBF resource
C901200059 reallocation success of channel activate for
LLC transmission
Number of EGPRS UL TBF resource
C901200060 reallocation failure due to LLC transmission

Number of EGPRS UL TBF resource


C901200061 reallocation success due to LLC
transmission
Number of EGPRS UL TBF resource
C901200064 reallocation failure due to Abis congestion
for resource request

188 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

Counter ID What It Counts


Number of EGPRS UL TBF resource
C901200065 reallocation failure due to RR congestion
for resource request
Number of EGPRS UL TBF resource
C901200066 reallocation failure due to UPPB-DSP
channel congestion for resource request
Number of EGPRS UL TBF resource
C901200067 reallocation success due to resource
request
Number of allocated PDCH for EGPRS UL
C901200068 TBF resource reallocation due to resource
request
Number of EGPRS UL TBF resource
C901200069 reallocation failure due to channel activate
failure for resource request
Number of EGPRS UL TBF resource
C901200070 reallocation failure due to BTS connection
failure for resource request
Number of EGPRS UL TBF resource
C901200071 reallocation failure due to BIU connection
failure for resource request
Number of EGPRS UL TBF resource
C901200072 reallocation success of channel activate for
resource request
Number of EGPRS UL TBF resource
C901200073 reallocation failure due to resource request

Number of EGPRS UL TBF resource


C901200074 reallocation success due to resource
request
Number of EGPRS UL TBF release due to
C901200075 flush LL

Number of EGPRS UL TBF release due to


C901200076 GPRS suspend requests

Number of EGPRS UL TBF forcing release


C901200077 by CS

Number of EGPRS UL TBF normal release


C901200078 due to user plane requests

Number of EGPRS UL TBF abnormal


C901200079 release due to user plane requests

Number of EGPRS UL TBF release due to


C901200080 NSVC unavailability

Number of EGPRS UL TBF release due to


C901200081 BVC unavailability

Confidential and Proprietary Information of ZTE CORPORATION 189


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


Number of EGPRS UL TBF release due to
C901200082 other reasons

Number of UL EGPRS TBF grab resources


C901200083

Number of grab instance by UL EGPRS TBF


C901200084

Number of UL EGPRS TBF queuing


C901200085

Number of UL EGPRS TBF queuing success


C901200086

Number of UL EGPRS TBF release TBF


C901200087 during queuing

C901200002
Definition Number of GPRS UL TBF establishment requests on CCCH
Description This counter is not used currently.

C901200003
Definition Number of EGPRS UL TBF establishment requests on CCCH
Description This counter counts the number of EGPRS channel requests on
CCCH when MS using EGPRS service
Usage This counter is used to find out the frequency of channel
requests on CCCH when MS attempts using EGPRS service.
Measurement When BSC receives channel requests on CCCH from MS, the
Point counter increments. The measurement point is A, as shown in
Figure 107.

FIGURE 107 - EGPRS CHANNEL REQUEST

BTS BSC

EGPRS Channel
Request
A

Unit Times

190 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

C901200004
Definition Number of GPRS UL TBF establishment requests on PCCCH
Description The counter is not used.

C901200005
Definition Number of EGPRS UL TBF establishment requests on PCCCH
Description This counter counts the number of packet channel requests on
PCCCH when MS attempts using EGPRS service
Usage This counter is used to find out the frequency of channel
requests on PCCCH when MS attempts using EGPRS service.
Measurement When BSC receives channel requests on PCCCH from MS, the
Point counter increments. The measurement point is A, as shown in
Figure 108.

FIGURE 108 - EGPRS P ACKET CHANNEL REQUEST

Unit Times

C901200006
Definition Number of GPRS UL TBF establishment requests on PACCH
Description The counter counts the number of UL EGPRS TBF establishment
attempts on PACCH.
Usage This counter is used to find out the number of UL EGPRS TBF
establishment attempts on PACCH under the situation when DL
GPRS TBF is already established.
Measurement In the situation when DL EGPRS TBF is established, PS control
Point plane receives UL assignment request message from PS user
plane, the counter increments. The measurement point is A, as
shown in Figure 66.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 191


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901200007
Definition Number of cell attempts for UL assignment due to ONE PHASE
access.
Description This counter counts the number of channel requests on CCCH
when MS attempting UL EGPRS TBF establishment or the
number of packet channel requests on PCCCH due to one phase
access.
Usage This counter is used to find out the number of UL EGPRS TBF
establishment attempts due to one phase access.
Measurement The counter accumulates at the following two time points:
Point
„ If BSC receives channel requests from MS on CCCH due to
one phase access, the counter increments. The measurement
point is A, as shown in Figure 109.

FIGURE 109 - EGPRS CHANNEL REQUESTS ON CCCH DUE TO ONE PHASE


ACCESS

BTS BSC

Channel Request(due to one phase


access)
A

„ If BSC receives EGPRS Packet channel request from MS on


PCCCH due to one phase access, the counter increments.
The measurement point is A, as shown in Figure 110.

FIGURE 110 - EGPRS P ACKET CHANNEL REQUESTS ON CCCH DUE TO ONE


PHASE ACCESS

BTS BSC

EGPRS Packet Channel Request(due to one


phase access)

Unit Times

C901200008
Definition Number of cell attempts for UL assignment due to single block
packet access
Description This counter is no used currently.

192 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

C901200009
Definition Number of cell attempts for UL assignment due to response
paging
Description This counter is not used currently.

C901200010
Definition Number of cell attempts for UL assignment due to cell updating
Description This counter is not used currently.

C901200011
Definition Number of cell attempts for UL assignment due to mobility
management.
Description The counter is not used currently.

C901200012
Definition Number of cell attempts for UL assignment due to TWO PHASE
access
Description This counter counts the number of channel requests on CCCH
when MS attempting UL EGPRS TBF establishment or the
number of packet channel requests on PCCCH due to two phase
access.
Usage This counter is used to find out the number of UL EGPRS TBF
establishment attempts due to two phase access.
Measurement The counter accumulates at the following two time points:
Point
„ If BSC receives EGPRS channel requests from MS on CCCH
due to two phase access, the counter increments. The
measurement point is A, as shown in Figure 111

FIGURE 111 - EGPRS CHANNEL REQUESTS ON CCCH DUE TO TWO PHASE


ACCESS

BTS BSC

EGPRS Channel Request(due to two


phase access)

Confidential and Proprietary Information of ZTE CORPORATION 193


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

„ If BSC receives EGPRS Packet channel request from MS on


CCCH due to one phase access, the counter increments. The
measurement point is A, as shown in Figure 112.

FIGURE 112 - EGPRS P ACKET CHANNEL REQUESTS ON PCCCH DUE TO TWO


PHASE ACCESS

Unit Times

C901200013
Definition Number of cell attempts for UL assignment due to short access
Description This counter counts the number of EGPRS channel request on
CCCH or EGPRS Packet channel request on PCCCH when MS
attempting UL EGPRS TBF establishment due to short access.
Usage This counter is used to find out the number of UL EGPRS TBF
establishment attempts due to short access.
Measurement The counter accumulates at the following two time points:
Point
„ If BSC receives EGPRS channel requests from MS on CCCH
due to short access, the counter increments. The
measurement point is A, as shown in Figure 113.

FIGURE 113 - EGPRS CHANNEL REQUESTS ON CCCH DUE TO SHORT


ACCESS

„ If BSC receives EGPRS Packet channel request from MS on


PCCCH due to short access, the counter increments. The
measurement point is A, as shown in Figure 114.

194 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

FIGURE 114 - EGPRS P ACKET CHANNEL REQUESTS ON PCCCH DUE TO TWO


PHASE ACCESS

BTS BSC

EGPRS Packet Channel Request(due to short


access)

Unit Times

C901200015
Definition Number of EGPRS UL TBF establishment failure due to Abis
congestion
Description The counter records the number of DB resource application
failure when attempting UL EGPRS TBF establishment due to
Abis congestion.
Usage This counter is used to find out the number of DB resource
application failure when attempting UL EGPRS TBF establishment
due to Abis congestion.
Measurement The counter accumulates at the following two time points:
Point
„ If PS control plane receives EGPRS channel requests from MS
on CCCH or EGPRS Packet channel requests on PCCCH and
fails to apply for DB resource due to Abis congestion, the
counter increments. The measurement point is A, as shown
in Figure 115.

FIGURE 115 - DB RESOURCE REQUESTS FAILURE DUE TO ABIS CONGESTION


(EGPRS)

„ If PS control panel receives UL channel requests from PS


user plane when DL EGPRS TBF exists and fails to apply for
DB resource due to Abis congestion, the counter increments.
The measurement point is A, as shown in Figure 78
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 195


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901200016
Definition Number of EGPRS UL TBF establishment failure due to RR
congestion
Description The counter records the number of DB resource request failure
when attempting UL EGPRS TBF establishment due to radio
resource congestion. There are three causes that lead to radio
resource congestion: MS per channel (MS number on each
channel reaches its maximum), no TAI/TFI and no PDCH
Usage This counter is used to find out the number of DB resource
application failure when attempting UL EGPRS TBF establishment
due to RR congestion.
Measurement The counter accumulates at the following two time points:
Point
„ If PS control plane receives EGPRS channel request from MS
on CCCH or EGPRS Packet channel request on PCCCH and
fails to apply for DB resource due to RR congestion, the
counter increments. The measurement point is A, as shown
in Figure 116.

FIGURE 116 - DB RESOURCE REQUESTS FAILURE DUE TO RR CONGESTION


(EGPRS)

„ If PS control panel receives UL channel requests from PS


user plane when DL EGPRS TBF exists and fails to apply for
DB resource due to RR congestion, the counter increments.
The measurement point is A, as shown in Figure 81.
Unit Times

C901200017
Definition Number of EGPRS UL TBF establishment failure due to UPPB-DSP
channel congestion
Description The counter records the number of DB resource application
failure when attempting UL EGPRS TBF establishment due to
UPPB-DSP channel congestion.
Usage This counter is used to find out the number of DB resource
application failure when attempting UL EGPRS TBF establishment
due to UPPB-DSP channel congestion.

196 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

Measurement The counter accumulates at the following two time points:


Point
„ If PS control plane receives EGPRS channel request from MS
on CCCH or EGPRS Packet channel request on PCCCH and
fails to apply for DB resource due to UPPB-DSP channel
congestion, the counter increments. The measurement point
is A, as shown in Figure 117.

FIGURE 117 - DB RESOURCE REQUESTS FAILURE DUE TO UPPB-DSP


CHANNEL CONGESTION (EGPRS)

„ If PS control panel receives UL assignment request messages


from PS user plane on CCCH (DL GPRS TBF already
established) and fails to apply for DB resource due to UPPB-
DSP congestion, the counter increments. The measurement
point is A, as shown in Figure 84.
Unit Times

C901200018
Definition Number of EGPRS UL TBF establishment channel allocate
success
Description This counter counts the number of DB resource request
successes when attempting UL EGPRS TBF establishment.
Usage This counter is used to find out the number of DB resource
request successes when attempting UL GPRS TBF establishment.
Measurement If PS control plane receives EGPRS channel requests from MS on
Point CCCH or EGPRS Packet channel request on PCCCH and succeeds
in applying for DB resource, the counter increments. The
measurement point is A, as shown in Figure 118.

FIGURE 118 - DB RESOURCE REQUEST SUCCESSES (EGPRS)

Confidential and Proprietary Information of ZTE CORPORATION 197


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Unit Times

C901200019
Definition Number of cell success for EGPRS UL assignment due to ONE
PHASE access
Description This counter counts the number of successful UL EGPRS TBF
establishment due to one phase access.
Usage This counter is used to find out the number of UL EGPRS TBF
establishment successes due to one phase access.
Measurement The counter accumulates at the following two time points:
Point
„ If BSC receives EGPRS channel request from MS on CCCH
due to one phase access, the counter increments. The
measurement point is A, as shown in Figure 119

FIGURE 119 - DB RESOURCE REQUEST SUCCESSES ON CCCH DUE TO ONE


PHASE ACCESS

„ If BSC receives EGPRS packet channel request from MS on


PCCCH due to one phase access, the counter increments.
The measurement point is A, as shown in Figure 120.

FIGURE 120 - DB RESOURCE REQUEST SUCCESSES ON PCCCH DUE TO ONE


PHASE ACCESS

Unit Times

C901200020
Definition

198 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

Number of cell success for EGPRS UL assignment due to single


block packet access
Description This counter is not used.

C901200021
Definition Number of cell success for EGPRS UL assignment due to
response paging
Description This counter is not used.

C901200022
Definition Number of cell success for EGPRS UL assignment due to cell
updating
Description This counter is not used.

C901200023
Definition Number of cell success for EGPRS UL assignment due to mobility
management
Description This counter is not used.

C901200024
Definition Number of cell success for EGPRS UL assignment due to TWO
PHASE access
Description This counter counts the number of successful UL EGPRS TBF
establishment due to two phase access.
Usage This counter is used to find out the number of successful UL
EGPRS TBF establishment due to two phase access.
Measurement The counter accumulates at the following two time points:
Point
„ If BSC receives EGPRS channel requests from MS on CCCH
due to two phase access and DB resource request succeeds,
the counter increments. The measurement point is A, as
shown in Figure 121.

Confidential and Proprietary Information of ZTE CORPORATION 199


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 121 - EGPRS DB RESOURCE REQUEST SUCCESSES DUE TO TWO


PHASE ACCESS (CCCH)

„ If BSC receives EGPRS packet channel requests from MS on


PCCCH due to two phase access and DB resource request
succeeds, the counter increments. The measurement point is
A, as shown in Figure 122.

FIGURE 122 - DB RESOURCE REQUEST SUCCESSES ON PCCCH DUE TO TWO


PHASE ACCESS

Unit Times

C901200025
Definition Number of cell success for EGPRS UL assignment due to short
access
Description This counter counts the number of successful UL EGPRS TBF
establishment due to short access.
Usage This counter is used to find out the number of successful UL
GPRS TBF establishment due to short access.
Measurement The counter accumulates at the following two time points:
Point
„ If BSC receives EGPRS channel requests from MS on CCCH
due to short access and DB resource request succeeds, the
counter increments. The measurement point is A, as shown
in Figure 123.

200 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

FIGURE 123 - EGPRS DB RESOURCE REQUEST SUCCESSES DUE TO SHORT


ACCESS (CCCH)

„ If BSC receives EGPRS packet channel requests from MS on


PCCCH due to short access and DB resource request
succeeds, the counter increments. The measurement point is
A, as shown in Figure 124.

FIGURE 124 - EGPRS DB RESOURCE REQUEST SUCCESSES DUE TO SHORT


ACCESS (PCCCH)

Unit Times

C901200026
Definition Number of allocated PDCH for EGPRS UL TBF establishment
Description This counter counts the number of successfully assigned PDTCH
when UL EGPRS TBF successfully established.
Usage This counter is used to find out the number of successfully
assigned PDTCH when UL EGPRS TBF successfully established.
Measurement When PS control plane receives EGPRS channel requests on
Point CCCH from MS or EGPRS Packet channel request on PCCCH and
DB resource requests succeed, the counter increments. The
measurement point is A, as shown in Figure 118.
Unit Times

C901200027
Definition Number of EGPRS UL TBF establishment failure due to channel
activate failed

Confidential and Proprietary Information of ZTE CORPORATION 201


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Description This counter counts the number of PDTCH activate failure when
establishing UL EGPRS TBF.
Usage This counter is used to find out the number of PDTCH activate
failure when establishing UL EGPRS TBF (including initially
establish UL TBF and establish UL TBF when DL TBF exists).
Measurement The counter accumulates at the following two time points:
Point
„ When BSC receives PDTCH channel activate failure message
reported by BTS, the counter increments. The measurement
point is A, as shown in Figure 38.
„ When “wait for PDTCH channel activation and connection
response” counter times out and BSC fails to receive PDTCH
activate response message reported by BTS, this counter
increments.
Unit Times

C901200028
Definition Number of EGPRS UL TBF establishment failure due to BTS
connection failed
Description This counter counts the number of failure to establish UL EGPRS
TBF due to BTS connection failure.
Usage This counter is used to find out the number of UL EGPRS TBF
establishment failure (including initially establish UL TBF and
establish UL TBF when DL TBF exists) due to BTS connection
failure.
Measurement The counter accumulates at the following two time points:
Point
„ When PS control plane receives connection failure message
reported by connection module due to BTS connection failure,
the counter increments. The measurement point is A, as
shown in Figure 39.
„ When “wait for PDTCH channel activate and connection
response” counter times out and BSC fails to receive
connection success response message reported by
connection module, this counter increments.
Unit Times

C901200029
Definition Number of EGPRS UL TBF establishment failure due to BIU
connection failed
Description This counter counts the number of failure to establish UL EGPRS
TBF due to BIU connection failure.
Usage

202 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

This counter is used to find out the number of UL EGPRS TBF


establishment failure (including initially establish UL TBF and
establish UL TBF when DL TBF exists) due to BIU connection
failure.
Measurement When PS control plane receives connection failure message
Point reported by connection modules due to BIU connection failure,
the counter increments. The measurement point is A, as shown
in Figure 40.
Unit Times

C901200030
Definition Number of EGPRS UL TBF channel activate establishment
success
Description This counter counts the number of channel activate and
connection successes when establishing UL EGPRS TBF.
Usage This counter is used to find out the number of channel activate
and connection successes when establishing UL EGPRS TBF.
Measurement When PS control plane receives channel activate response
Point message reported by BTS and connection successes
acknowledgement message reported by connection module, the
counter increments. The measurement point is A, as shown in
Figure 49.
Unit Times

C901200031
Definition Number of EGPRS UL TBF establishment failure due to not
receive PIA
Description This counter counts the number of failure to send immediate
assignment message to MS when establishing UL EGPRS TBF.
Usage This counter is used to find out the number of failure to send
immediate assignment message to MS when establishing UL
EGPRS TBF.
Measurement The counter accumulates at the following two time points:
Point
„ When PS control plane receives immediate assignment
failure message reported by BTS, the counter increments.
The measurement point is A, as showed in Figure 43.
„ When “wait for immediate assignment and sending
indication” counter times out and BSC fails to receive
immediate assignment and sending indication message, the
counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 203


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901200032
Definition Number of EGPRS UL TBF establishment failure on PCCCH/CCCH
due to UPPB-DSP.
Description This counter counts the number of failure to establish UL GPRS
TBF.
Usage This counter is used to find out the number of failure to establish
UL EGPRS TBF.
Measurement When PS control plane assigns single block through two phase
Point access from PS user plane, or gets access to PS user plane
through one phase access and starts assignment timer. If the
timer times out, resource request from PS user plane (two phase
access) is not received or indication (one phase access) is not
established, the counter increments. The measurement point is
A, as shown in Figure 96.
Unit Times

C901200033
Definition Number of EGPRS UL TBF establishment failure on PACCH due to
UPPB-DSP congestion
Description This counter is not used currently.

C901200034
Definition Number of EGPRS UL TBF establishment success on
PCCCH/CCCH
Description This counter counts the number of successful UL EGPRS TBF
establishment and receiving MS TLL1.
Usage This counter is used to find out the number of successful UL
GPRS TBF establishment and receiving MS TLL1.
Measurement The counter accumulates at the following two time points:
Point
„ When PS control plane receives MS TLL1 “MAC establishment
indication” message reported by PS user plane in the
premise of one phase access, the counter increments. The
measurement point is A, as shown in Figure 97.
„ PS control plane receives resource request message from PS
user plane in the premise of two phase access, the counter
increments. The measurement point is A, as shown in Figure
98.
Unit Times

204 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

C901200035
Definition Number of GPRS UL TBF establishment success on PACCH
Description This counter is not used currently.

C901200038
Definition Number of EGPRS UL TBF resource reallocation failure due to
Abis congestion for DL TBF
Description In the situation when UL EGPRS TBF is already established, DL
TBF is needed to be established on PACCH; DB resource request
fails which leads to UL resource reallocation failure. The counter
records the number of UL EGPRS TBF reallocation failure due to
Abis resource congestion.
Usage This counter is used to find out the number of UL GPRS TBF
reallocation failure due to Abis congestion.
Measurement In the situation when UL EGPRS TBF is established, PS control
Point plane receives DL assignment request message from PS user
plane, and DB resource request fails due to Abis congestion, the
counter increments. The measurement point is A, as shown in
Figure 32.
Unit Times

C901200039
Definition Number of EGPRS UL TBF resource reallocation failure due to RR
congestion for DL TBF
Description In the situation when UL GPRS TBF is already established, DL
TBF is needed to be established on PACCH; DB resource request
fails which leads to UL resource reallocation failure. The counter
records the number of UL resource reallocation failure due to RR
resource congestion.
There are three causes which lead to radio resource congestion:
MS per channel (MS number per channel reaches its maximum),
TAI/TFI (no TAI or TFI available) and no PDCH available.
Usage This counter is used to find out the number of UL EGPRS TBF
reallocation failure due to RR congestion.
Measurement In the situation when UL EGPRS TBF is established, PS control
Point plane receives DL assignment request message from PS user
plane, and DB resource request fails due to RR congestion, the
counter increments. The measurement point is A, as shown in
Figure 34
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 205


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901200040
Definition Number of EGPRS UL TBF resource reallocation failure due to
UPPB-DSP channel congestion.
Description In the situation when UL EGPRS TBF is already established, DL
TBF is needed to be established on PACCH; DB resource request
fails which leads to UL resource reallocation failure. The counter
records the number of EGPRS UL resource reallocation failure
due to UPPB-DSP channel resource congestion.
Usage This counter is used to find out the number of UL EGPRS TBF
reallocation failure due to UPPB-DSP channel congestion.
Measurement In the situation when UL EGPRS TBF is established, PS control
Point plane receives DL assignment request message from PS user
plane, and DB resource request fails due to UPPB-DSP channel
congestion, the counter increments. The measurement point is A,
as shown in Figure 36.
Unit Times

C901200041
Definition Number of EGPRS UL TBF resource reallocation success due to
DL TBF establishment
Description The counter records the number of successful DL TBF
establishment on PACCH when UL EGPRS TBF is already
established.
Usage This counter is used to find out the number of DL EGPRS TBF
reallocation successes.
Measurement In the situation when UL EGPRS TBF is established, PS control
Point plane receives DL assignment request message from PS user
plane, and DB resource request succeeds, the counter
increments. The measurement point is A, as shown in Figure 37.
Unit Times

C901200042
Definition Number of allocated PDCH for EGPRS UL TBF resource
reallocation due to DL TBF establishment
Description The counter records the number of successful allocated PDTCH
when UL EGPRS TBF is successfully reallocated.
Usage This counter is used to find out the number of successful
allocated PDTCH when UL EGPRS TBF is successfully reallocated.
Measurement In the situation when UL EGPRS TBF is established, PS control
Point plane receives DL assignment request message from PS user

206 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

plane, and DB resource request succeeds, the counter


increments. The measurement point is A, as shown in Figure 37.
Unit Times

C901200043
Definition Number of EGPRS UL TBF resource reallocation failure due to
channel activate failure for DL TBF establishment
Description The counter records the number of PDTCH activate failure during
UL GPRS TBF resource reallocation.
Usage This counter is used to find out the number of PDTCH activate
failure during UL EGPRS TBF resource reallocation.
Measurement The counter accumulates at the following two time points:
Point
„ When BSC receives PDTCH channel activate failure message
from BTS, the counter increments. The measurement point is
A, as shown in Figure 38.
„ When “Wait for PDTCH channel activation and connection
response” timer times out, and BSC fails to receive PDTCH
channel activate response message from BTS, the counter
increments.
Unit Times

C901200044
Definition Number of EGPRS UL TBF resource reallocation failure due to
BTS connection failure for DL TBF establishment
Description The counter records the number of BTS connection failure during
UL EGPRS TBF resource reallocation.
Usage This counter is used to find out the number of BTS connection
failure during UL EGPRS TBF resource reallocation.
Measurement The counter accumulates at the following two time points:
Point
„ When PS control plane receives connection failure message
from connection module due to BTS connection failure, the
counter increments. The measurement point is A, as shown
in Figure 39.
„ When Wait for PDTCH channel activation and connection
response” timer times out, and BSC fails to receive
connection success message from connection module, the
counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 207


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901200045
Definition Number of EGPRS UL TBF resource reallocation failure due to
BIU connection failure for DL TBF establishment
Description The counter records the number of BIU connection failure during
UL EGPRS TBF resource reallocation.
Usage This counter is used to find out the number of BIU connection
failure during UL EGPRS TBF resource reallocation.
Measurement When PS control plane receives connection failure message from
Point connection module due to BIU connection failure, the counter
increments. The measurement point is A, as shown in Figure 40.
Unit Times

C901200046
Definition Number of EGPRS UL TBF resource reallocation success of
channel activate for DL TBF establishment
Description The counter records the number of channel activate and
connection successes during UL EGPRS TBF resource reallocation.
Usage This counter is used to find out the number of channel activate
and connection successes during UL EGPRS TBF resource
reallocation.
Measurement When PS control plane receives channel activate ack message
Point and connection success ack message from connection module
due to BIU connection failure, the counter increments. The
measurement point is A, as shown in Figure 49.
Unit Times

C901200047
Definition Number of EGPRS UL TBF resource reallocation failure due to DL
TBF establishment.
Description The counter is not used currently.

C901200048
Definition Number of EGPRS UL TBF resource reallocation success due to
DL TBF establishment
Description The counter is not used currently.

208 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

C901200051
Definition Number of EGPRS UL TBF resource reallocation failure due to
Abis congestion for LLC
Description During UL EGPRS TBF transmission process, PS user plane sends
resource reallocation message to PS control plane due to LLC
frame change; PS control plane requests DB resource after
receiving the message. The counter records the number of DB
resource request failure due to Abis resource congestion after PS
control plane receiving resource reallocation request during UL
EGPRS TBF transmission process.
Usage This counter is used to find out DB resource request failure due
to Abis resource congestion after PS control plane receiving
resource reallocation request during UL EGPRS TBF transmission
process..
Measurement When PS control plane receives resource reallocation message
Point from PS user plane, and DB resource request fails due to Abis
congestion, the counter increments. The measurement point is A,
as shown in Figure 42.
Unit Times

C901200052
Definition Number of EGPRS UL TBF resource reallocation failure due to RR
congestion for LLC
Description During UL EGPRS TBF transmission process, PS user plane sends
resource reallocation message to PS control plane due to LLC
frame change; PS control plane requests DB resource after
receiving the message. The counter records the number of DB
resource request failure due to radio resource congestion after
PS control plane receiving resource reallocation request during
UL EGPRS TBF transmission process.
There are three causes leading to RR congestion: MS per
channel (reaches its maximum), TAI/TFI (not available), and no
PDTCH.
Usage This counter is used to find out DB resource request failure due
to RR congestion after PS control plane receiving resource
reallocation request during UL EGPRS TBF transmission process.
Measurement When PS control plane receives resource reallocation message
Point from PS user plane, and DB resource request fails due to RR
congestion, the counter increments. The measurement point is A,
as shown in Figure 43.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 209


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901200053
Definition Number of EGPRS UL TBF resource reallocation failure due to
UPPB-DSP channel congestion
Description During UL EGPRS TBF transmission process, PS user plane sends
resource reallocation message to PS control plane due to LLC
frame change; PS control plane requests DB resource after
receiving the message. The counter records the number of DB
resource request failure due to UPPB-DSP channel congestion
after PS control plane receiving resource reallocation request
during UL EGPRS TBF transmission process.
Usage This counter is used to find out DB resource request failure due
to UPPB-DSP channel congestion after PS control plane receiving
resource reallocation request during UL EGPRS TBF transmission
process.
Measurement When PS control plane receives resource reallocation message
Point from PS user plane, and DB resource request fails due to UPPB-
DSP channel congestion, the counter increments. The
measurement point is A, as shown in Figure 44.
Unit Times

C901200054
Definition Number of EGPRS UL TBF resource reallocation success due to
LLC transmission
Description During UL EGPRS TBF transmission process, PS user plane sends
resource reallocation message to PS control plane due to LLC
frame change; PS control plane requests DB resource after
receiving the message. The counter records the number of DB
resource request successes after PS control plane receiving
resource reallocation request during UL EGPRS TBF transmission
process.
Usage This counter is used to find out DB resource request success due
after PS control plane receiving resource reallocation request
during UL EGPRS TBF transmission process.
Measurement When PS control plane receives resource reallocation message
Point from PS user plane, and DB resource request succeeds, the
counter increments. The measurement point is A, as shown in
Figure 45.
Unit Times

C901200055
Definition

210 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

Number of allocated PDCH for EGPRS UL TBF resource


reallocation due to LLC transmission.
Description During UL EGPRS TBF transmission process, PS user plane sends
resource reallocation message to PS control plane due to LLC
frame change; PS control plane requests DB resource after
receiving the message. The counter records the number of
successfully allocated PDTCH after PS control plane receiving
resource reallocation requests during UL EGPRS TBF.
Usage This counter is used to find out the number of successful
allocated PDTCH when UL EGPRS TBF is successfully reallocated.
Measurement When PS control plane receives resource reallocation message
Point from PS user plane, and DB resource request succeeds, the
counter increments. The measurement point is A, as shown in
Figure 45
Unit Times

C901200056
Definition Number of EGPRS UL TBF resource reallocation failure due to
channel activate failure for LLC transmission
Description The counter records the number of PDTCH activate failure after
BSC receiving resource reallocation request during UL EGPRS
TBF resource reallocation.
Usage This counter is used to find out the number of PDTCH activate
failure during UL EGPRS TBF resource reallocation.
Measurement The counter accumulates at the following two time points:
Point
„ When BSC receives PDTCH channel activate failure message
from BTS, the counter increments. The measurement point is
A, as shown in Figure 38
„ When “Wait for PDTCH channel activation and connection
response” timer times out, and BSC fails to receive PDTCH
channel activate response message from BTS, the counter
increments.
Unit Times

C901200057
Definition Number of EGPRS UL TBF resource reallocation failure due to
BTS connection failure for LLC transmission
Description The counter records the number of connection failure due to BTS
connection failure after BSC receiving resource reallocation
request during UL EGPRS TBF transmission.
Usage This counter is used to find out the number of BTS connection
failure during UL EGPRS TBF resource transmission.

Confidential and Proprietary Information of ZTE CORPORATION 211


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Measurement The counter accumulates at the following two time points:


Point
„ When PS control plane receives connection failure message
from connection module due to BTS connection failure, the
counter increments. The measurement point is A, as shown
in Figure 39
„ When “Wait for PDTCH channel activation and connection
response” timer times out, and BSC fails to receive
connection success message from connection module, the
counter increments.
Unit Times

C901200058
Definition Number of EGPRS UL TBF resource reallocation failure due to
BIU connection failure for LLC transmission
Description The counter records the number of BIU connection failure during
UL GPRS TBF transmission.
Usage This counter is used to find out the number of BIU connection
failure during UL EGPRS TBF transmission.
Measurement When PS control plane receives connection failure message from
Point connection module due to BIU connection failure, the counter
increments. The measurement point is A, as shown in Figure 40.
Unit Times

C901200059
Definition Number of EGPRS UL TBF resource reallocation success of
channel activate for LLC transmission
Description The counter records the number of channel activate and
connection successes during UL EGPRS TBF transmission.
Usage This counter is used to find out the number of channel activate
and connection successes during UL EGPRS TBF tranmission.
Measurement When PS control plane receives channel activate ack message
Point and connection success ack message from connection module
due to BIU connection failure, the counter increments. The
measurement point is A, as shown in Figure 49.
Unit Times

C901200060
Definition Number of EGPRS UL TBF resource reallocation failure due to
LLC transmission.

212 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

Description The counter is not used currently.

C901200061
Definition Number of EGPRS UL TBF resource reallocation success due to
LLC transmission.
Description The counter is not used currently.

C901200062
Definition Number of GPRS UL TBF resource reallocation requests for
resource request
Description The counter is not used currently.

C901200064
Definition Number of EGPRS UL TBF resource reallocation failure due to
Abis congestion for resource request
Description The counter records the number of DB resource request failure
due to Abis congestion after PS control plane resource request
from MS during UL EGPRS TBF.
Usage This counter is used to find out the number of DB resource
request failure after PS control plane receives resource request
from MS during UL EGPRS TBF process (including UL two-phase
access and UL TBF transmission).
Measurement PS control plane receives resource request message from PS
Point user plane, and DB resource request fails due to Abis congestion,
the counter increments. The measurement point is A, as shown
in Figure 99.
Unit Times

C901200065
Definition Number of EGPRS UL TBF resource reallocation failure due to RR
congestion for resource reques
Description The counter records the number of DB resource request failure
after PS control plane receives resource request from MS due to
RR congestion during UL EGPRS TBF.
There are three cause leading to radio resource congestion: MS
per channel (MS number per channel reaches its maximum),
TAI/TFI (no TAI/TFI available), no PDCH(no PS service channel
available)

Confidential and Proprietary Information of ZTE CORPORATION 213


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Usage This counter is used to find out the number of DB resource


request failure after PS control plane receives resource request
from MS due to RR congestion during UL EGPRS TBF process
(including UL two-phase access and UL TBF transmission).
Measurement PS control plane receives resource request message from MS,
Point and DB resource request fails due to RR congestion, the counter
increments. The measurement point is A, as shown in Figure 100.
Unit Times

C901200066
Definition Number of EGPRS UL TBF resource reallocation failure due to
UPPB-DSP channel congestion for resource request
Description The counter records the number of DB resource request failure
after PS control plane receives resource request from MS due to
UPPB-DSP channel congestion during UL EGPRS TBF.
Usage This counter is used to find out the number of DB resource
request failure after PS control plane receives resource request
from MS due to UPPB-DSP channel congestion during UL EGPRS
TBF process (including UL two-phase access and UL TBF
transmission).
Measurement PS control plane receives resource request message from PS
Point user plane, and DB resource request fails due to RR congestion,
the counter increments. The measurement point is A, as shown
in Figure 101.
Unit Times

C901200067
Definition Number of EGPRS UL TBF resource reallocation success due to
resource request
Description The counter records the number of successful DB resource
request after PS control plane receives resource request
message from MS during UL EGPRS TBF process.
Usage This counter is used to find out the number of DB resource
request successes after PS control plane receives resource
request from MS during UL EGPRS TBF process (including UL
two-phase access and UL TBF transmission).
Measurement PS control plane receives resource request message from PS
Point user plane, and DB resource request succeeds, the counter
increments. The measurement point is A, as shown in Figure 102.
Unit Times

214 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

C901200068
Definition Number of allocated PDCH for EGPRS UL TBF resource
reallocation due to resource request
Description The counter records the number of successful allocated PDTCH
after PS control plane receives resource request message from
MS during UL EGPRS TBF process.
Usage This counter is used to find out the number of successful
allocated PDTCH after PS control plane receives resource request
from MS during UL EGPRS TBF process (including UL two-phase
access and UL TBF transmission).
Measurement PS control plane receives resource request message from PS
Point user plane, and DB resource request succeeds, the counter
increments. The measurement point is A, as shown in Figure 102.
Unit Times

C901200069
Definition Number of EGPRS UL TBF resource reallocation failure due to
channel activate failure for resource request
Description The counter records the number of PDTCH activate failure during
UL EGPRS TBF resource reallocation after PS control plane
receives resource request message.
Usage The counter records the number of PDTCH activate failure during
UL EGPRS TBF resource reallocation after PS control plane
receives resource request message in UL GPRS TBF
process(including UL two-phase access and one-phase TBF
transmission).
Measurement The counter accumulates at the following two time points:
Point
„ When BSC receives PDTCH channel activate failure message
from BTS, the counter increments. The measurement point is
A, as shown in Figure 38.
„ When “Wait for PDTCH channel activation and connection
response” timer times out, and BSC fails to receive PDTCH
channel activate response message from BTS, the counter
increments.
Unit Times

C901200070
Definition Number of EGPRS UL TBF resource reallocation failure due to
BTS connection failure for resource request
Description

Confidential and Proprietary Information of ZTE CORPORATION 215


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

The counter records the number of connection failure due to BTS


connection failure during UL EGPRS TBF resource reallocation
after PS control plane receives resource request message.
Usage The counter records the number of connection failure due to BTS
connection failure during UL EGPRS TBF resource reallocation
after PS control plane receives resource request message in UL
GPRS TBF process (including UL two-phase access and one-
phase TBF transmission).
Measurement The counter accumulates at the following two time points:
Point
„ When PS control plane receives connection failure message
from connection module due to BTS connection failure, the
counter increments. The measurement point is A, as shown
in Figure 39.
„ When “Wait for PDTCH channel activation and connection
response” timer times out, and BSC fails to receive
connection success message from connection module, the
counter increments.
Unit Times

C901200071
Definition Number of EGPRS UL TBF resource reallocation failure due to
BIU connection failure for resource request
Description The counter records the number of connection failure due to BIU
connection failure during UL EGPRS TBF resource reallocation
after PS control plane receives resource request message.
Usage The counter records the number of connection failure due to BIU
connection failure during UL EGPRS TBF resource reallocation
after PS control plane receives resource request message in UL
EGPRS TBF process (including UL two-phase access and one-
phase TBF transmission).
Measurement When PS control plane receives connection failure message from
Point connection module due to BIU connection failure, the counter
increments. The measurement point is A, as shown in Figure 40.
Unit Times

C901200072
Definition Number of EGPRS UL TBF resource reallocation success of
channel activate for resource request
Description The counter records the number of channel activate and
connection successes during UL EGPRS TBF resource reallocation
after PS control plane receives resource request message.
Usage

216 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

The counter records the number of channel activate and


connection failure during UL EGPRS TBF resource reallocation
after PS control plane receives resource request message in UL
EGPRS TBF process (including UL two-phase access and one-
phase TBF transmission).
Measurement When PS control plane receives channel activate ack message
Point and connection success ack message from connection module
due to BIU connection failure, the counter increments. The
measurement point is A, as shown in Figure 49.
Unit Times

C901200073
Definition Number of EGPRS UL TBF resource reallocation failure due to
resource request.
Description The counter is not used currently.

C901200074
Definition Number of EGPRS UL TBF resource reallocation success due to
resource request
Description The counter is not used currently.

C901200075
Definition Number of EGPRS UL TBF release due to flush LL
Description This counter counts the number of UL EGPRS TBF release after
PS control plane receiving request due to flush LL.
Usage This counter is used to find out the number of UL EGPRS TBF
release after PS control plane receiving request due to flush LL.
Measurement When PS control plane of BSC receives FLUSH message from
Point SGSN and release is executed when UL EGPRS TBF is established,
the counter increments. The measurement point is A, as shown
in Figure 54.
Unit Times

C901200076
Definition Number of EGPRS UL TBF release due to GPRS suspend requests
Description

Confidential and Proprietary Information of ZTE CORPORATION 217


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This counter counts the number of UL EGPRS TBF release after


PS control plane receiving request due to GPRS suspend
requests.
Usage This counter is used to find out the number of UL EGPRS TBF
release due to EGPRS suspend requests.
Measurement When PS control plane of BSC receives SUSPEND message from
Point SGSN and release is executed when UL EGPRS TBF is established,
the counter increments. The measurement point is A, as shown
in Figure 55.
Unit Times

C901200077
Definition Number of EGPRS UL TBF forcing release by CS
Description This counter counts the number of UL EGPRS TBF forcing release
by CS.
Usage This counter is used to find out the number of UL EGPRS TBF
forcing release by CS..
Measurement When PS control plane of BSC receives PDCH RELEASE message
Point from CS control plane when UL EGPRS TBF is established, the
counter increments. The measurement point is A, as shown in
Figure 56.
Unit Times

C901200078
Definition Number of EGPRS UL TBF normal release due to user plane
requests.
Description This counter counts the number of UL EGPRS TBF normal release
due to user plane requests.
Usage This counter is used to find out the number of UL EGPRS TBF
normal release due to user plane requests.
Measurement When PS control plane of BSC receives NORMAL RELEASE
Point REQUEST message from PS user plane when UL EGPRS TBF
exists, the counter increments. The measurement point is A, as
shown in Figure 57.
Unit Times

C901200079
Definition Number of EGPRS UL TBF abnormal release due to user plane
requests

218 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

Description This counter counts the number of UL EGPRS TBF abnormal


release due to user plane requests.
Usage This counter is used to find out the number of UL EGPRS TBF
abnormal release due to user plane requests.
Measurement When PS control plane receives ABNORMAL RELEASE REQUEST
Point message from PS user plane when UL EGPRS TBF exists, the
counter increments. The measurement point is A, as shown in
Figure 58.
Unit Times

C901200080
Definition Number of EGPRS UL TBF release due to NSVC unavailability
Description This counter counts the number of UL EGPRS TBF release due to
NSVC unavailability.
Usage This counter is used to find out the number of UL EGPRS TBF
release after receiving forcing release request due to NSVC
unavailability
Measurement When PS control plane receives NSVC unavailability command to
Point release PS control plane module from DB when UL EGPRS TBF
exists, the counter increments. The measurement point is A, as
shown in Figure 59.
Unit Times

C901200081
Definition Number of EGPRS UL TBF release due to BVC unavailability
Description This counter counts the number of UL EGPRS TBF release due to
BVC unavailability.
Usage This counter is used to find out the number of UL EGPRS TBF
release after receiving forcing release request due to BVC
unavailability
Measurement When PS control plane receives BVC unavailability command to
Point release PS control plane module from DB when UL EGPRS TBF
exists, the counter increments. The measurement point is A, as
shown in Figure 60.
Unit Times

C901200082
Definition Number of EGPRS UL TBF release due to other reasons.
Description

Confidential and Proprietary Information of ZTE CORPORATION 219


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This counter counts the number of UL EGPRS TBF forcing release


due to other reasons.
Usage This counter is used to find out the number of UL EGPRS TBF
release after receiving forcing release request due to other
reasons.
Measurement When PS control plane receives release message due to other
Point reasons when UL EGPRS TBF exists, the counter increments. The
measurement point is A, as shown in Figure 64.
Unit Times

C901200083
Definition Number of UL EGPRS TBF grab resources
Description This counter counts the number of UL EGPRS TBF grab resources.
Usage This counter is used to find out the frequency for UL EGPRS TBF
grabbing other TBF resource.
Measurement This counter increments while UL EGPRS TBF is established during
Point resource adjustment, resource request is successful, and other TBF
resource is grabbed. Measurement point is A as shown in Figure 125.

FIGURE 125 - UL EGPRS RESOURCE REQUEST SUCCESS

PSPS控制面
control plane Database
数据库
Request resource (UP
申请资源(上行
EGPRS)EGPRS)

申请资源成功
Request resource success

Unit Times

C901200084
Definition Number of grab instance by UL EGPRS TBF
Description This counter counts the number of grab instance by UL EGPRS TBF.
Usage This counter is used to find out the frequency for UL EGPRS TBF
grabbing other TBF resource.
Measurement This counter increments while UL EGPRS TBF is established during
Point resource adjustment, resource request is successful, and other TBF
resource is grabbed. Measurement point is A as shown in Figure 125.
Unit Times

220 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Uplink EGPRS Data TBF Statistics

C901200085
Definition Number of UL EGPRS TBF queuing
Description This counter counts the number of UL EGPRS TBF queuing.
Usage This counter is used to find out the frequency for UL EGPRS TBF queuing.
Measurement This counter increments while UL EGPRS TBF is established during
Point resource adjustment, resource request is successful but queuing is
required due to incompliant to QoS rate. Measurement point is A as
shown in Figure 125.
Unit Times

C901200086
Definition Number of UL EGPRS TBF queuing success
Description This counter counts the number of UL EGPRS TBF queuing
success.
Usage This counter is used to find out the frequency for UL EGPRS TBF
queuing success.
Measurement This counter increments while UL EGPRS TBF is established
Point during resource adjustment, the instance to be queued
successfully assigns resource for user, and database is
successfully registered. Measurement point is A as shown in
Figure 125.
Unit Times

C901200087
Definition Number of UL EGPRS TBF release TBF during queuing
Description This counter counts the number of UL EGPRS TBF release during
queuing.
Usage This counter is used to find out the frequency for UL EGPRS TBF
release during queuing.
Measurement This counter increments while UL EGPRS TBF is released and
Point instance still in queuing state. The measurement point is A as
shown in Figure 126.

Confidential and Proprietary Information of ZTE CORPORATION 221


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 126 - RELEASE UL EGPRS TBF

PS控制面
PS control plane

Release UL EGPRS TBF,


释放上行EGPRS TBF,
instance still in queuing
实例仍在排队
A

Unit Times

222 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9

BSSGP Flow Statistic

BSSGP flow statistics task considers cell as a measurement


entity, statistics content includes the number of paging, BVC
blocking/unblocking as so on. This chapter introduces the
meaning, usage, and measurement point of different BSSGP flow
statistics counters.

Overview
BSSGP flow statistics mainly measures the message
transmission condition at Gb BSSGP level in GPRS service, to
count different signaling messages. This includes the number of
packet paging, circuit paging, BVC block, BVC unblock, BVC
reset, location request, and location result response, etc.
The measurement takes cell as the statistics unit.

BSSGP Flow Statistics Counter


Index
Table 13 lists counters related to BSSGP flow statistics.

TABLE 13 - BSSGP FLOW STATISTICS COUNTER

Counter ID What It Counts


C901210001 Number of paging PS message
C901210002 Number of paging CS message
C901210003 Number of Flush-LL Message received
C901210004 Number of Flush-LL-ACK Message sent
C901210005 Number of BVC-BLOCK message sent
C901210006 Number of BVC-BLOCK-ACK message received
C901210007 Number of BVC-UNBLOCK message sent

Confidential and Proprietary Information of ZTE CORPORATION 223


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


C901210008 Number of BVC-UNBLOCK-ACK message received
C901210009 Number of BVC-RESET message sent
C901210010 Number of BVC-RESET-ACK message received
C901210011 Number of BVC-RESET message received
C901210012 Number of BVC-RESET-ACK message sent
C901210013 Number of PERFORM-LOCATION-REQUEST
message received
C901210014 Number of PERFORM-LOCATION-RESPONSE
message sent
C901210015 Number of PERFORM-LOCATION-ABORT message
received
C901210016 Number of POSITION-COMMAND message sent
C901210017 Number of POSITION-RESPONSE message received
C901210018 Number of Flush-LL received if UL/DL TBF exist
C901210019 Number of Flush-LL received if DL TBF exist
C901210020 Number of Flush-LL received if UL TBF exist
C901210021 Number of reroute intra NSE
C901210022 Number of reroute inter NSE intra BSS cell
C901210023 Number of reroute inter NSE inter BSS cell

C901210001
Definition Number of paging PS message
Description SGSN sending packet paging message indicates that BSC
originates packet paging for MS in designated cell. This counter
counts the number of receiving this message.
Measurement When BSC receives a “PAGING PS” message, this counter
Point increments. The measurement point is A, as shown in Figure 127.

FIGURE 127 - P AGING PS PROCESS

Unit Times

224 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - BSSGP Flow Statistic

C901210002
Definition Number of paging GS message
Description SGSN sending circuit paging message indicates BSC originates
circuit paging for MS in designated cell. This counter counts the
number of receiving this message.
Measurement When BSC receives a “PAGING CS” message, this counter
Point increments. The measurement point is A, as shown in Figure 128.

FIGURE 128 - P AGING CS PROCESS

BSC SGSN

PAGING CS

Unit Times

C901210003
Definition Number of Flush-LL Message received
Description SGSN sends “FLUSH-LL” message to notify of BSS MS to do
inter-cell handover, and this counter counts the number of
receiving this message by BSC.
Usage By viewing the number of receiving this message by BSC, to
check the MS handover condition.
Measurement When BSC receives a “FLUSH-LL” message, this counter
Point increments. The measurement point is A1, as shown in Figure
129.

FIGURE 129 - FLUSH-LL PROCESS

BSC SGSN
FLUSH-LL

A1
FLUSH-LL-ACK

A2

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 225


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901210004
Definition Number of Flush-LL-ACK Message sent
Description BSC sends “FLUSH-LL-ACK” message to notify SGSN: LLC PDU
buffered for this MS by pervious cell has been removed or
transferred to new cell under same routing area. This counter
counts the number of sending this message by BSC.
Measurement When BSC sends a “FLUSH-LL-ACK” message, this counter
Point increments. The measurement point is A2, as shown in Figure
129.
Unit Times

C901210005
Definition Number of BVC-BLOCK message sent
Description BSC sending BVC block message indicates BVC designated by
SGSN blocking. This counter counts the number of blocking
designated BVC by BSC.
Measurement When BSC sends a “BVC-BLOCK” message, this counter
Point increments. The measurement point is A1, as shown in Figure
130.

FIGURE 130 - BVC BLOCKING PROCESS

Unit Times

C901210006
Definition Number of BVC-BLOCK-ACK message received
Description SGSN sends BVC blocking confirmation message to notify of
designated BVC blocked by BSC, and this counter counts the
number of receiving this message by BSC.
Measurement When BSC receives a “BVC-BLOCK-ACK” message, this counter
Point increments. The measurement point is A2, as shown in Figure
130.
Unit Times

226 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - BSSGP Flow Statistic

C901210007
Definition Number of BVC-UNBLOCK message sent
Description BSC sends BVC unblocking message indicates BVC designated by
SGSN unblocking, and this counter counts the number of
unblocking designated BVC by BSC.
Measurement When BSC sends a “BVC-UNBLOCK” message, this counter
Point increments. The measurement point is A1, as shown in Figure
131.

FIGURE 131 - BVC UNBLOCKING PROCESS

Unit Times

C901210008
Definition Number of BVC-UNBLOCK-ACK message received
Description SGSN sends BVC unblocking confirmation message to notify of
designated BVC unblocked by BSC, and this counter counts the
number of receiving this message by BSC.
Measurement When BSC receives a “BVC-UNBLOCK-ACK” message, this
Point counter increments. The measurement point is A2, as shown in
Figure 131.
Unit Times

C901210009
Definition Number of BVC-RESET message sent
Description BSC sends BVC reset message indicates SGSN resets designated
BVC, and this counter counts the number of resetting designated
BVC by BSC actively.
Measurement When BSC sends a “BVC-RESET” message, this counter
Point increments. The measurement point is A1, as shown in Figure
132.

Confidential and Proprietary Information of ZTE CORPORATION 227


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 132 - BVC RESET PROCESS

Unit Times

C901210010
Definition Number of BVC-RESET-ACK message received
Description SGSN sends BVC reset confirmation message to notify of
designated BVC reset by BSC, and this counter counts the
number of receiving this message by BSC.
Measurement When BSC receives a “BVC-RESET-ACK” message, this counter
Point increments. The measurement point is A2, as shown in Figure
132.
Unit Times

C901210011
Definition Number of BVC-RESET message received
Description SGSN sends BVC reset message indicates BSC resets designated
BVC, and this counter will count the number of resetting BVC by
SGSN actively.
Measurement When BSC receives a “BVC-RESET” message, this counter
Point increments. The measurement point is A3, as shown in Figure
132.
Unit Times

C901210012
Definition Number of BVC-RESET-ACK message sent
Description BSC sends BVC reset confirmation message to notify of
designated BVC reset by SGSN, and this counter counts the
number of sending this message by BSC.

228 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - BSSGP Flow Statistic

Measurement When BSC sends a “BVC-RESET-ACK” message, this counter


Point increments. The measurement point is A1, as shown in Figure
132.
Unit Times

C901210013
Definition Number of PERFORM-LOCATION-REQUEST message received
Description SGSN sends location request message to request BSC to do a
locating process for MS. This counter counts the number of
receiving this message by BSC.
Usage By viewing the number of receiving locating request message by
BSC, you can view the frequency of locating service.
Measurement When BSC receives a “PERFORM-LOCATION-REQUEST” message,
Point this counter increments. The measurement point is A1, as shown
in Figure 133.

FIGURE 133 - PERFORM LOCATING PROCESS

Unit Times

Note:
The broken line in this figure indicates that the position of this
message can be changed.

C901210014
Definition Number of PERFORM-LOCATION-RESPONSE message sent

Confidential and Proprietary Information of ZTE CORPORATION 229


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Description After BSC finishes locating process, send locating response


message to notify SGSN of locating result for MS. This counter
counts the number of sending this message by BSC.
Usage By viewing the number of sending this message by BSC, you can
view the frequency of locating service.
Measurement When BSC sends a “PERFORM-LOCATION- RESPONSE” message,
Point this counter increments. The measurement point is A1, as shown
in Figure 133.
Unit Times

C901210015
Definition Number of PERFORM-LOCATION-ABORT message received
Description SGSN sends abort locating message to request BSC abort
current locating process. This counter counts the number of
receiving this message by BSC.
Measurement When BSC receives a “PERFORM-LOCATION-ABORT” message,
Point this counter increments. The measurement point is A1, as shown
in Figure 133.
Unit Times

C901210016
Definition Number of POSITION-COMMAND message sent
Description BSC sends locating command message to request SGSN perform
locating command process. This counter counts the number of
sending this message by BSC.
Measurement When BSC sends a “POSITION-COMMAND” message, this
Point counter increments. The measurement point is A2, as shown in
Figure 133.
Unit Times

C901210017
Definition Number of POSITION-RESPONSE message received
Description SGSN sends “POSITION-RESPONSE” message to notify BSC of
response result for locating command result. This counter counts
the number of receiving this message by BSC.
Measurement When BSC receives a “POSITION-RESPONSE” message, this
Point counter increments. The measurement point is A3, as shown in
Figure 133.
Unit Times

230 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - BSSGP Flow Statistic

C901210018
Definition Number of Flush-LL received if UL/DL TBF exist
Description SGSN sends “FLUSH-LL” message to notify of BSC MS passed
inter-cell handover. This counter counts the number of receiving
“FLUSH-LL” message during data service made by MS.
Measurement Each time BSC receives a “FLUSH-LL” message and MS is
Point conducting DL data service, this counter increments. The
measurement point is A, as shown in Figure 134.

FIGURE 134 - RECEIVE FLUSH-LL FOR UL & DL TBF

Unit Times

C901210019
Definition Number of Flush-LL received if DL TBF exist
Description SGSN sends “FLUSH-LL” message to notify of BSC MS passed
inter-cell handover. This counter counts the number of receiving
“FLUSH-LL” message during DL data service made by MS.
Measurement When BSC receives a “FLUSH-LL” message and MS is conducting
Point DL data service, this counter increments. The measurement
point is A, as shown in Figure 135.

Confidential and Proprietary Information of ZTE CORPORATION 231


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 135 - RECEIVE FLUSH-LL FOR DL TBF

MS BSS SGSN

DL-UNITDATA

RLC DATA BLOCK


RLC DATA BLOCK
FLUSH-LL
A
FLUSH-LL-ACK

Unit Times

C901210020
Definition Number of Flush-LL received if UL TBF exist
Description SGSN sends “FLUSH-LL” message to notify of BSC MS passed
inter-cell handover. This counter counts the number of receiving
“FLUSH-LL” message during UL data service made by MS.
Measurement When BSC receives a “FLUSH-LL” message and MS is conducting
Point UL data service, this counter increments. The measurement
point is A, as shown in Figure 136.

FIGURE 136 - RECEIVE FLUSH-LL FOR UL TBF

MS BSS SGSN

RLC DATA BLOCK


RLC DATA BLOCK
UL-UNITDATA

FLUSH-LL

A
FLUSH-LL-ACK

Unit Times

C901210021
Definition Number of reroute intra NSE
Description SGSN sends “FLUSH-LL” message to notify of BSS MS passed
inter-cell handover. This counter counts the number of receiving
this message by BSC, and the number of same NSE for new and
previous cells.

232 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - BSSGP Flow Statistic

Measurement When BSC receives a “FLUSH-LL” message and new and


Point previous cells are same NSE, this counter increments. The
measurement point is A1, as shown in Figure 129.
Unit Times

C901210022
Definition Number of reroute inter NSE intra BSS cell
Description SGSN sends “FLUSH-LL” message to notify of BSS MS passed
inter-cell handover. This counter counts the number of receiving
this message by BSC, and the number of same BSS and
different NSEs for new and previous cells.
Measurement When BSC receives a “FLUSH-LL” message and new and
Point previous cells are same BSS or different NSEs, this counter
increments. The measurement point is A1, as shown in Figure
129.
Unit Times

C901210023
Definition Number of reroute inter NSE inter BSS cell
Description SGSN sends “FLUSH-LL” message to notify of BSS MS passed
inter-cell handover. This counter counts the number of receiving
this message by BSC, and the number of different BSSs and
NSEs for new and previous cells.
Measurement When BSC receives a “FLUSH-LL” message, and new and
Point previous cells are different BSSs or NSEs, this counter
increments. The measurement point is A1, as shown in Figure
129.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 233


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This page is intentionally blank.

234 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10

TRX Measurement

TRX measurement task mainly considers TRX as its object to


count its resource distribution, seizure, assignment, traffic, and
interference, as an evidence of carrier, channel configuration,
and relevant parameter adjustment.
This chapter introduces the meaning and measurement point to
measure different performance counters by TRX.

Overview
TRX measurement is to measure the success or failure condition
of channel activation, assignment, and handover in the unit of
carrier. It also can measure carrier interference band, maximum
and minimum UL & DL level condition, to learn the status of
different carriers, providing evidence for adjustment and
maintenance.

TRX Measurement Counter Index


Table 14 lists counters related to TRX measurement.

TABLE 14 - TRX MEASUREMENT COUNTER

Counter ID What It Counts


C901230001 Number of intra-cell handover in attempts
C901230002 Number of intra-cell handover ins success
Number of Intra-BSC inter-cell handover in
C901230003
attempts
Number of Intra-BSC intra-cell handover ins
C901230004
success
Number of Intra-MSC inter-cell handover in
C901230005
attempts
C901230006 Number of Intra-MSC inter-cell handover ins

Confidential and Proprietary Information of ZTE CORPORATION 235


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Counter ID What It Counts


success
C901230007 TCH busy time
C901230008 Number of TCH seizures (including handover)
C901230009 Number of call drops due to TCH LAPD breakage
C901230010 Number of call drops due to TCH radio link failure
C901230011 Number of TCH handover call drops
Number of TCH/F activation attempts (including
C901230012
handover)
Number of TCH/F activation success (including
C901230013
handover)
C901230014 Number of TCH/F assignment attempts
C901230015 Number of TCH/F assignment success
Number of TCH/H activation attempts (including
C901230016
handover)
Number of TCH/H activation success (including
C901230017
handover)
C901230018 Number of TCH/H assignment attempts
C901230019 Number of TCH/H assignment success
C901230020 SDCCH busy time
C901230021 Number of attempts for SDCCH
C901230022 Number of SDCCH call drops
Number of SDCCH activation attempts (including
C901230023
handover)
Number of SDCCH activation success (including
C901230024
handover)
C901230025 Number of SDCCH assignment attempts
C901230026 Number of SDCCH assignment success
C901230027 Number of samples with UL RQ = 0
C901230028 Number of samples with UL RQ = 1
C901230029 Number of samples with UL RQ = 2
C901230030 Number of samples with UL RQ = 3
C901230031 Number of samples with UL RQ = 4
C901230032 Number of samples with UL RQ = 5
C901230033 Number of samples with UL RQ = 6
C901230034 Number of samples with UL RQ = 7
C901230035 Number of samples with DL RQ = 0
C901230036 Number of samples with DL RQ = 1
C901230037 Number of samples with DL RQ = 2
C901230038 Number of samples with DL RQ = 3

236 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - TRX Measurement

Counter ID What It Counts


C901230039 Number of samples with DL RQ = 4
C901230040 Number of samples with DL RQ = 5
C901230041 Number of samples with DL RQ = 6
C901230042 Number of samples with DL RQ = 7
Mean number of idle TCH/Fs with interference band
C901230043
0
Mean number of idle TCH/Fs with interference band
C901230044
1
Mean number of idle TCH/Fs with interference band
C901230045
2
Mean number of idle TCH/Fs with interference band
C901230046
3
Mean number of idle TCH/Fs with interference band
C901230047
4
Mean number of idle TCH/Fs with interference band
C901230048
5
Mean number of idle TCH/Hs with interference
C901230049
band 0
Mean number of idle TCH/Hs with interference
C901230050
band 1
Mean number of idle TCH/Hs with interference
C901230051
band 2
Mean number of idle TCH/Hs with interference
C901230052
band 3
Mean number of idle TCH/Hs with interference
C901230053
band 4
Mean number of idle TCH/Hs with interference
C901230054
band 5
Mean number of idle SDCCHs with interference
C901230055
band 0
Mean number of idle SDCCHs with interference
C901230056
band 1
Mean number of idle SDCCHs with interference
C901230057
band 2
Mean number of idle SDCCHs with interference
C901230058
band 3
Mean number of idle SDCCHs with interference
C901230059
band 4
Mean number of idle SDCCHs with interference
C901230060
band 5
C901230061 Number of TRX poweroff
C901230062 Duration of TRX poweroff

Confidential and Proprietary Information of ZTE CORPORATION 237


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901230001
Definition Number of intra-cell handover in attempts
Description Normally, intra-cell handover is triggered by receiving level,
receiving quality, interference, and concentric circle, its source
cell is same as target cell. During intra-cell handover, first send
CHANNEL ACTIVATE message to target channel, and BTS
responds CHANNEL ACTIVATE ACK message.

FIGURE 137 - INTRA-CELL HANDOVER

Measurement During intra-cell handover, measurement point will be counted


Point after BSC receives CHANNEL ACTIVATE ACK. The measurement
point is A, as shown in Figure 137.
Unit Times

C901230002
Definition Number of intra-cell handover ins success
Description During intra-cell handover, after target channel is successfully
activated, BSC will send ASSIGNMENT COMMAND message to
MS through source channel. After BSC receives ASSIGNMENT
COMPLETE of MS from target channel, intra-cell handover is
successfully completed.
Measurement During intra-cell handover, the measurement point will be
Point counted after receive ASSIGNMENT COMPLETE. The
measurement point is A2, as shown in Figure 137.
Unit Times

C901230003
Definition Number of Intra-BSC inter-cell handover in attempts

238 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - TRX Measurement

Description During inter-cell handover controlled by BSC, source and target


cells are different cells under same BSC. During inter-cell
handover, first send CHANNEL ACTIVATE message to target
channel.

FIGURE 138 - INTER-CELL HANDOVER CONTROLLED BY BSC

MS BTS (Source) BTS (Target) BSC

CHANNEL ACT

CHANNEL ACT ACK

A1
HANDOVER COMMAND HANDOVER COMMAND

HANDOVER COMPLETE HANDOVER COMPLETE

A2

Measurement During inter-cell handover controlled by BSC, measurement


Point point will be counted after BSC receives CHANNEL ACTIVATE
ACK. The measurement point is A1, as shown in Figure 138.
Unit Times

C901230004
Definition Number of Intra-BSC intra-cell handover ins success
Description During inter-cell handover controlled by BSC, after target
channel is successfully activated, BSC will send handover
command to MS through source channel. After BSC receives
HANDOVER COMPLETE message of MS from target channel,
inter-cell handover is successfully completed.
Measurement During inter-cell handover controlled by BSC, measurement point will be
Point counted after BSC receives HANDOVER COMPLETE message. The
measurement point is A2, as shown in Figure 138.
Unit Times

C901230005
Definition Number of Intra-MSC inter-cell handover in attempts
Description Inter-cell handover controlled by MSC is conducted after BSC
receives HANDOVER REQUEST message from MSC. After BSC
receives handover request message, first send CHANNEL
ACTIVATE to acquisition target channel.
Measurement During inter-cell handover (incoming) controlled by MSC,
Point measurement point will be counted after BSC receives CHANNEL

Confidential and Proprietary Information of ZTE CORPORATION 239


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

ACTIVATE ACK. The measurement point is A1, as shown in


Figure 138.
Unit Times

C901230006
Definition Number of Intra-MSC inter-cell handover ins success
Description During inter-cell handover controlled by MSC, after target
channel is successfully activated and target channel receives
HANDOVER COMPLETE message sent by MS, handover is
successfully done.
Measurement During inter-cell handover controlled by MSC, measurement
Point point will be counted after BSC receives HANDOVER COMPLETE
message from MS. The measurement point is A2, as shown in
Figure 138.
Unit Times

C901230007
Definition TCH busy time
Description To count used time in voice channel on carrier, including TCH/F
and TCH/H. This can reflect carrier traffic.
Measurement formula is: (current time – last measured time) *
the number of MS seizing channel. Reported measurement value
shall be gotten by accumulation of each measurement value.
After each accumulation, previous measured time will be
changed to current time; at measurement point A, the number
of MS seizing channel will be incremented after accumulation; at
measurement point B, the number of MS seizing channel will be
decremented after accumulation.
Measurement There are 3 measurement points.
Point
„ Accumulate while successfully acquire voice channel resource
„ Accumulate while release voice channel resource
„ Accumulate by regular measurement and acquisition
Unit Second

C901230008
Definition Number of TCH seizures (including handover)
Description The number of seizure voice channel on carrier, including TCH/F
and TCH/H. This can reflect the traffic busy degree of carrier.

240 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - TRX Measurement

Measurement Count while successfully acquire voice channel resource.


Point

Unit Times

C901230009
Definition Number of call drops due to TCH LAPD breakage
Description When LAPD link is disconnected, the call on carrier will be
interrupted, and this counter will record call interruption
condition caused by disconnected LAPD.
Measurement Count while receive LAPD Disconnected message.
Point

Unit Times

C901230010
Definition Number of call drops due to TCH radio link failure
Description When radio link quality is poor or level is low, and unable to
change to other cells, the call on carrier will be interrupted. This
counter records the call interruption condition caused by radio
link failure.
Measurement Count while receiving radio link failure message. The
Point measurement point is A, as shown in Figure 139.

FIGURE 139 - BSC RECEIVES RADIO LINK FAILURE MESSAGE REPORTED BY


BTS

Unit Times

C901230011
Definition Number of TCH handover call drops
Description During handover, if HANDOVER COMMAND or ASSIGNMENT
COMMAND (intra-cell handover) has been sent, but BSC doesn’t

Confidential and Proprietary Information of ZTE CORPORATION 241


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

receive HANDOVER COMPLETE message or ASSIGNMENT


COMPLETE message during guard time, the handover is failed
and intra-cell handover and BSC controlled inter-cell handover
will be interrupted. This counter records the call interruption
condition caused by handover failure.
Measurement This counter will count at following cases:
Point
„ When receiving T3013 timer timeout message. The measurement
point is A2, as shown in Figure 140.

FIGURE 140 - INTER-CELL HANDOVER FAILURE

„ When receiving T3107 timer timeout message. The measurement


point is A2, as shown in Figure 141.

FIGURE 141 - INTRA-CELL HANDOVER FAILURE

MS BTS BSC

CHANNEL ACTIVATE

CHANNEL ACTIVATE ACK

A1
ASSIGNMENT COMMAND
SET T3107

T3107 Timeout
A2

Unit Times

C901230012
Definition Number of TCH/F activation attempts (including handover)

242 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - TRX Measurement

Description Count the number of originating CHANNEL ACTIVATE messages


from carrier TCH/F channel.
Measurement Count after BSC sends CHANNEL ACTIVATE message to BTS.
Point The measurement point is A1, as shown in Figure 142.

FIGURE 142 - CHANNEL ACTIVATION MEASUREMENT POINT

Unit Times

C901230013
Definition Number of TCH/F activation success (including handover)
Description Count the number of successful activation from carrier TCH/F
channel.
Measurement Count after BSC receives CHANNEL ACTIVATE ACK message. The
Point measurement point is A2, as shown in Figure 142.
Unit Times

C901230014
Definition Number of TCH/F assignment attempts
Description Count the number of sending ASSIGNMENT COMMAND by BSC
while assigning TCH/F channel.
Measurement Count after BSC sends ASSIGNMENT COMMAND message to BTS.
Point The measurement point is A1, as shown in Figure 143.

Confidential and Proprietary Information of ZTE CORPORATION 243


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

FIGURE 143 - TCH/F CHANNEL ASSIGNMENT MEASUREMENT POINT

Unit Times

C901230015
Definition Number of TCH/F assignment success
Description When assign TCH/F channel, BSC sends ASSIGNMENT
COMMAND message to assignment channel, after BSC receives
EST IND or ASSIGNMENT COMPLETE message, channel
assignment is successful.
Measurement Count after BSC receives EST IND or ASSIGNMENT COMPLETE
Point message. The measurement point is A2, as shown in Figure 143.
Unit Times

C901230016
Definition Number of TCH/H activation attempts (including handover)
Description Count the number of originating channel activation from carrier
TCH/H channel.
Measurement Count after BSC sends CHANNEL ACTIVATE message to BTS.
Point The measurement point is A1, as shown in Figure 142.
Unit Times

C901230017
Definition Number of TCH/H activation success (including handover)
Description Count the number of successful activation from carrier TCH/H
channel.
Measurement Count after BSC receives CHANNEL ACTIVATE ACK message. The
Point measurement point is A2, as shown in Figure 142.

244 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - TRX Measurement

Unit Times

C901230018
Definition Number of TCH/H assignment attempts
Description Count the number of sending ASSIGNMENT COMMAND by BSC
while assigning TCH/H channel.
Measurement Count after BSC sends ASSIGNMENT COMMAND message to BTS.
Point The measurement point is A1, as shown in Figure 143.
Unit Times

C901230019
Definition Number of TCH/H assignment success
Description When assign TCH/H channel, BSC sends ASSIGNMENT
COMMAND message to assignment channel, after BSC receives
EST IND or ASSIGNMENT COMPLETE message, channel
assignment is successful.
Measurement Count after BSC receives EST IND or ASSIGNMENT COMPLETE
Point message. The measurement point is A2, as shown in Figure 143.
Unit Times

C901230020
Definition SDCCH busy time
Description Time used by SDCCH channel on carrier, including assignment
and handover. This can reflect traffic of carrier SDCCH channel.
Measurement formula is: (current time – last measured time) *
the number of MS seizing channel.
Reported measurement value shall be gotten by accumulation of
each measurement value. After each accumulation, previous
measured time will be changed to current time; when SDCCH
channel is seized, the number of MS seizing channel will be
incremented after accumulation; when SDCCH channel is
released, the number of MS seizing channel will be decremented
after accumulation.
Measurement There are 3 measurement points as follows.
Point
„ Accumulate while successfully acquire SDCCH channel resource
„ Accumulate while release SDCCH channel resource
„ Accumulate by regular measurement and acquisition
Unit Second

Confidential and Proprietary Information of ZTE CORPORATION 245


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901230021
Definition Number of attempts for SDCCH
Description Count the number of successful and failed SDCCH application
during assignment and handover.
Measurement Count after BSC applying for SDCCH is successful or failed.
Point

Unit Times

C901230022
Definition Number of SDCCH call drops
Description During assignment and handover, ASSIGNMENT COMPLETE or
HANDOVER COMPLETE is not received after send ASSIGNMENT
COMMAND or HANDOVER COMMAND message. After T3103 or
T3107 timer times out, it is considered as SDCCH failure, see
Figure 140 and Figure 141.
If handover to external cell, when HANDOVER COMMAND is
delivered, start THoOutGo, CLEAR COMMAND of MSC is not
received before THoOutGo times out, it is considered as SDCCH
failure, as shown in Figure 144.
In addition, when LAPD is broken or disconnected, if channel is
SDCCH, it will be recorded as SDCCH call drops.

FIGURE 144 - THOOUTGO TIMEOUT

Measurement This counter will count at following cases:


Point „ When BSC receives LAPD breakage message and channel is
SDCCH.
„ When BSC connection faults and channel is SDCCH.
„ After THoOutGo timer times out.
„ After T3103 timer times out.
„ After T3107 timer times out.

246 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - TRX Measurement

Unit Times

C901230023
Definition Number of SDCCH activation attempts (including handover)
Description Count the number of originating CHANNEL ACTIVATE messages
from carrier SDCCH channel.
Measurement Count after BSC sends CHANNEL ACTIVATE message to BTS.
Point The measurement point is A1, as shown in Figure 142.
Unit Times

C901230024
Definition Number of SDCCH activation success (including handover)
Description Count the number of successful activation from carrier SDCCH
channel.
Measurement Count after BSC receives CHANNEL ACTIVATE ACK message. The
Point measurement point is A2, as shown in Figure 142.
Unit Times

C901230025
Definition Number of SDCCH assignment attempts
Description When assign SDCCH channel, BSC assigns SDCCH channels by
sending IMMEDIATE ASSIGNMENT message or ASSIGNMENT
COMMAND message. This counter counts the number of SDCCH
assignment attempts.
Measurement Count after BSC sends IMMEDIATE ASSIGNMENT message or
Point ASSIGNMENT COMMAND to BTS. The measurement point is A1,
as shown in Figure 145.

FIGURE 145 - CHANNEL ASSIGNMENT MEASUREMENT POINT

Confidential and Proprietary Information of ZTE CORPORATION 247


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Unit Times

C901230026
Definition Number of SDCCH assignment success
Description When assign SDCCH channel, BSC sends IMMEDIATE
ASSIGNMENT message or ASSIGNMENT COMMAND message to
assignment channel, after BSC receives EST IND (CM SERV REQ),
channel assignment is successful.
Measurement Count after BSC receives EST IND (CM SERV REQ) message. The
Point measurement point is A2, as shown in Figure 145.
Unit Times

C901230027
Definition Number of samples with UL RQ = 0
Description BTS measures the level, quality, and interference of UL signal
received in channel, and reports it to BSC, in combination with
measurement report of DL signal reported by MS. Interval
between BTS measurement and report is consistent with that of
MS, that is, one measurement report is reported to BSC per
480ms.Measurement mechanism of following counter
C901230028~C901230042 is same as that of this measurement
value. This measurement value is the sample number with UL
RQ=0 in measurement report.
Measurement BSC receives the measurement report submitted by BTS, if UL
Point RQ=0 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.

FIGURE 146 - BSC RECEIVES THE MEASUREMENT REPORT SUBMITTED BY


BTS

BTS BSC

MEASUREMENT REPORT

Unit Times

C901230028
Definition Number of samples with UL RQ = 1
Description

248 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - TRX Measurement

This measurement value is the sample number with UL RQ=1 in


measurement report.
Measurement BSC receives the measurement report submitted by BTS, if UL
Point RQ=1 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230029
Definition Number of samples with UL RQ = 2
Description This measurement value is the sample number with UL RQ=2 in
measurement report.
Measurement BSC receives the measurement report submitted by BTS, if UL
Point RQ=2 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230030
Definition Number of samples with UL RQ = 3
Description This measurement value is the sample number with UL RQ=3 in
measurement report.
Measurement BSC receives the measurement report submitted by BTS, if UL
Point RQ=3 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230031
Definition Number of samples with UL RQ = 4
Description This measurement value is the sample number with UL RQ=4 in
measurement report.
Measurement BSC receives the measurement report submitted by BTS, if UL RQ=4 in
Point measurement report, this counter increments. The measurement point is
A, as shown in Figure 146.
Unit Times

C901230032
Definition Number of samples with UL RQ = 5

Confidential and Proprietary Information of ZTE CORPORATION 249


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Description This measurement value is the sample number with UL RQ=5 in


measurement report.
Measurement BSC receives the measurement report submitted by BTS, if UL
Point RQ=5 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230033
Definition Number of samples with UL RQ = 6
Description This measurement value is the sample number with UL RQ=6 in
measurement report.
Measurement BSC receives the measurement report submitted by BTS, if UL
Point RQ=6 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230034
Definition Number of samples with UL RQ = 7
Description This measurement value is the sample number with UL RQ=7 in
measurement report.
Measurement BSC receives the measurement report submitted by BTS, if UL
Point RQ=7 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230035
Definition Number of samples with DL RQ = 0
Description This measurement value is the sample number with DL RQ=1 in
measurement report.
Measurement BSC receives the measurement report submitted by BTS, if DL
Point RQ=0 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230036
Definition Number of samples with DL RQ = 1

250 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - TRX Measurement

Description This measurement value is the sample number with DL RQ=1 in


measurement report.
Measurement BSC receives the measurement report submitted by BTS, if DL
Point RQ=1 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230037
Definition Number of samples with DL RQ = 2
Description This measurement value is the sample number with DL RQ=2 in
measurement report.
Measurement BSC receives the measurement report submitted by BTS, if DL
Point RQ=2 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230038
Definition Number of samples with DL RQ = 3
Description This measurement value is the sample number with DL RQ=3 in
measurement report.
Measurement BSC receives the measurement report submitted by BTS, if DL RQ=3 in
Point measurement report, this counter increments. The measurement point is
A, as shown in Figure 146.
Unit Times

C901230039
Definition Number of samples with DL RQ = 4
Description This measurement value is the sample number with DL RQ=4 in
measurement report.
Measurement BSC receives the measurement report submitted by BTS, if UL
Point RQ=4 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230040
Definition Number of samples with DL RQ = 5

Confidential and Proprietary Information of ZTE CORPORATION 251


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Description This measurement value is the sample number with DL RQ=5 in


measurement report.
Measurement BSC receives the measurement report submitted by BTS, if DL
Point RQ=5 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230041
Definition Number of samples with DL RQ = 6
Description This measurement value is the sample number with DL RQ=6 in
measurement report.
Measurement BSC receives the measurement report submitted by BTS, if DL
Point RQ=6 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230042
Definition Number of samples with DL RQ = 7
Description This measurement value is the sample number with DL RQ=7 in
measurement report.
Measurement BSC receives the measurement report submitted by BTS, if DL
Point RQ=7 in measurement report, this counter increments. The
measurement point is A, as shown in Figure 146.
Unit Times

C901230043
Definition Mean number of idle TCH/Fs with interference band 0
Description Regularly query database, acquire idle TCH/F number at
different interference level on carrier, to represent average with
queried value. Interference level for different TCH/F channel in
database will be updated after BSC receives radio resource sent
by BTS. Measurement mechanism of following counter
C901230044~ C901230060 is same as that of this measurement
value. This measurement value is idle TCH/F number when
interference band is 0 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

252 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - TRX Measurement

C901230044
Definition Mean number of idle TCH/Fs with interference band 1
Description This measurement value is idle TCH/F number when interference
band is 1 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

C901230045
Definition Mean number of idle TCH/Fs with interference band 2
Description This measurement value is idle TCH/F number when interference
band is 2 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

C901230046
Definition Mean number of idle TCH/Fs with interference band 3
Description This measurement value is idle TCH/F number when interference
band is 3 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

C901230047
Definition Mean number of idle TCH/Fs with interference band 4
Description This measurement value is idle TCH/F number when interference
band is 4 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 253


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901230048
Definition Mean number of idle TCH/Fs with interference band 5
Description This measurement value is idle TCH/F number when interference
band is 5 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

C901230049
Definition Mean number of idle TCH/Hs with interference band 0
Description This measurement value is idle TCH/H number when
interference band is 0 in carrier.
Measurement Count when regularly query database
Point

Unit Times

C901230050
Definition Mean number of idle TCH/Hs with interference band 1
Description This measurement value is idle TCH/H number when
interference band is 1 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

C901230051
Definition Mean number of idle TCH/Hs with interference band 2
Description This measurement value is idle TCH/H number when
interference band is 2 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

254 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - TRX Measurement

C901230052
Definition Mean number of idle TCH/Hs with interference band 3
Description This measurement value is idle TCH/H number when
interference band is 3 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

C901230053
Definition Mean number of idle TCH/Hs with interference band 4
Description This measurement value is idle TCH/H number when
interference band is 4 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

C901230054
Definition Mean number of idle TCH/Hs with interference band 5
Description This measurement value is idle TCH/H number when
interference band is 5 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

C901230055
Definition Mean number of idle SDCCHs with interference band 0
Description This measurement value is idle SDCCH number when
interference band is 0 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 255


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901230056
Definition Mean number of idle SDCCHs with interference band 1
Description This measurement value is idle SDCCH number when
interference band is 1 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

C901230057
Definition Mean number of idle SDCCHs with interference band 2
Description This measurement value is idle SDCCH number when
interference band is 2 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

C901230058
Definition Mean number of idle SDCCHs with interference band 3
Description This measurement value is idle SDCCH number when
interference band is 3 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

C901230059
Definition Mean number of idle SDCCHs with interference band 4
Description This measurement value is idle SDCCH number when
interference band is 4 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

256 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - TRX Measurement

C901230060
Definition Mean number of idle SDCCHs with interference band 5
Description This measurement value is idle SDCCH number when
interference band is 5 in carrier.
Measurement Count when regularly query database.
Point

Unit Times

C901230061
Definition Number of TRX poweroff
Description This counter counts the number of TRX smart poweroff,
excluding normal POWER OFF.
Measurement This counter increments during smart poweron.
Point

Unit Times

C901230062
Definition Duration of TRX poweroff
Description This counter counts the duration of TRX poweroff.
Measurement This counter increments during smart poweron.
Point

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 257


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This page is intentionally blank.

258 Confidential and Proprietary Information of ZTE CORPORATION


Appendix A

Abbreviations

Abbreviation Full Name


A
Abis Abis Interface
AIPP A-Interface Peripheral Processor
AIU A-Interface Unit
AUC Access Unit Controller
B
BCCH Broadcast Channel
BSC Base Station Controller
BTS Base Transceiver Station
BSSAP Base Station Subsystem Application Part
BSSGP Base Station Subsystem GPRS Protocol
BSSMAP Base Station Subsystem Management
Application Part
BTS Base Transceiver Station
BVC BSSGP Virtual Connection
BVCI BSSGP Virtual Connection Identifier
C
CBCH Cell Broadcast Channel
CC Call Control
CCCH Common Control Channel
CCH Control Channel
CS Circuit Switched
D
DRT Dual Rate Transcoder
DTAP Direct Transfer Application Part
E

Confidential and Proprietary Information of ZTE CORPORATION 259


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Abbreviation Full Name


EDRT Enhanced Dual Rate Transcoder
EGSM Extended GSM
F
FACCH Fast Associated Control Channel
FACCH/F Fast Associated Control Channel/Full rate
FACCH/H Fast Associated Control Channel/Half rate
FR Frame Relay
FRP Frame Relay Protocol
FU Frame Unit
G
GGSN Gateway GPRS Support Node
GIU GPRS Interface Unit
GPRS General Packet Radio Service
GSM Global System for Mobile communication
GSN GPRS Support Node
H
HSN Hopping Sequence Number
K
KPI Key Performance Indicator
L
LAPD Link Access Protocol of D-Channel
LLC Logical Link Control
LMT Local Management Terminal
LOC Location update
M
MM Mobility Management
MOC Mobile Originated Call
MS Mobile Station
MSC Mobile Switching Center
MO-SM MS Originated Short Message
MT-SM MS Terminated Short Message
MTC Mobile Terminated Call
MTP Message Transfer Part
N
NC Network Controller
NMS Network Management Signaling
NMS Network Management Software

260 Confidential and Proprietary Information of ZTE CORPORATION


Appendix A - Abbreviations

Abbreviation Full Name


NS Network Service
NSE Network Service Entity
NSEI Network Service Entity Identifier
NSVC Network Service Virtual Circuit
O
OMC Operation Maintenance Center
OMCR Operation Maintenance Center Radio
P
PACCH Packet Associated Control Channel
PAGCH Paging and Access Grant Channel
PBGT Power Budget
PCH Paging Channel
PCU Packet Control Unit
PDU Protocol Data Unit
PDCH Packet Data Channel
PDTCH Packet Data Traffic Channel
PDU Protocol Data Unit
PS Packet Switched
R
RMM Radio Management Module
RQ Receiving Quality
RR Radio Resource
S
SACCH Slow Associated Control Channel
SACCH/F Slow Associated Control Channel/Full rate
SACCH/H Slow Associated Control Channel/Half rate
SAPI Service Access Point Identifier
SCCP Signal Correction Control Part
SDCCH Slow Distributed Control Channel
SGSN Serving GPRS Support Node
SIF Service Information Field
SIO Service Information Octets
SM Short Message
SMM Service Management Module
SMS Short Messages Service
SS Supplementary Services
T

Confidential and Proprietary Information of ZTE CORPORATION 261


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Abbreviation Full Name


TA Time Advance
TCH Traffic Channel
TCH/F Traffic Channel/Full rate
TCH/H Traffic Channel/Half rate
TFO Tandem Free Operation
TIC Trunk Interface Circuit
TRX Transceiver
U
UISF User Interface Support Foundation

262 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B

Figures

Figure 1 – Intra-Cell Handover Attempt ............................... 12


Figure 2 – Intra-Cell Incoming handover .............................. 12
Figure 3 – Successful Intra-Cell Handover ............................ 13
Figure 4 - Inter-cell Handover Execution .............................. 16
Figure 5 – Successful Intra-Cell Handover ............................ 17
Figure 6 - Handover Decision ............................................. 17
Figure 7 – MS Measurement Report..................................... 43
Figure 8 - Flow of MO Short Messages during Conversation .... 57
Figure 9 - Flow of MT Short Message during Conversation ...... 59
Figure 10 - Flow of MT Short Message in Idle Status .............. 63
Figure 11 - Flow of MO Short Message in Idle Status ............. 64
Figure 12 – Measurement Point of Packet Resource Request and
Packet Access Reject......................................................... 71
Figure 13 – Measurement Point of Packet UL Assignment
Message.......................................................................... 72
Figure 14 – Measurement Point of Additional MS Access
Capabilities Message ......................................................... 72
Figure 15 – DL Sent on PACCH in Packet Transmission Mode ... 73
Figure 16 - DL Sent on PACCH in Packet Transmission Mode ... 74
Figure 17 - Signaling Transmission on PACCH ....................... 75
Figure 18 – Measurement Point of Packet-Cell-Change-Related
Counter (1) ..................................................................... 76
Figure 19 – Measurement Point of Packet-Cell-Change-Related
Counter (2) ..................................................................... 77
Figure 20 – Measurement Point of Packet Cell Change Order and
Packet Cell Change Failure ................................................. 78
Figure 21 – Measurement Point of Packet Mobile Status Message
on PACCH........................................................................ 79

Confidential and Proprietary Information of ZTE CORPORATION 263


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Figure 22 – Measurement Point of DL TBF Establishes execution


Polling ............................................................................ 80
Figure 23 – Measurement Point of Packet Power Control/Timing
Advance Message Sent on PACCH ....................................... 80
Figure 24 – Measurement Point of Packet-Service-Cell-Data-
Related Counter ............................................................... 81
Figure 25 – Flow of Establishing UL on PACCH under DL
Transmission Status.......................................................... 82
Figure 26 – Flow of Establishing DL on PACCH under UL
Transmission Status.......................................................... 83
Figure 27 – Measurement Point of BSC Issuing Packet Paging
Request Message.............................................................. 83
Figure 28 – Measurement Point of BSC Issuing Packet System
Message.......................................................................... 84
Figure 29 – DL Request ..................................................... 88
Figure 30 – DL Assignment Request .................................... 89
Figure 31 – Database Application Failure due to Abis Congestion
I .................................................................................... 90
Figure 32 – Database Application Failure due to Abis Congestion
II ................................................................................... 90
Figure 33 – Database Application Failure due to RR Congestion I
..................................................................................... 91
Figure 34 – Database Application Failure due to RR Congestion II
..................................................................................... 91
Figure 35 – Database Application Failure due to UPPB-DSP
Channel Congestion I ........................................................ 92
Figure 36 – Database Application Failure due to UPPB-DSP
Channel Congestion II....................................................... 92
Figure 37 – Successful Resource Application ......................... 93
Figure 38 – PDCH Activation Failure .................................... 94
Figure 39 – Connection Failure due to BTS Connection Failed .. 94
Figure 40 – Connection Failure due to BIU Connection Failed .. 95
Figure 41 - DL GPRS TBF establishes channel activation and
access success ................................................................. 96
Figure 42 – Immediate Assignment Sending Failure............... 96
Figure 43 – Successful Immediate Assignment Sending ......... 97
Figure 44 – Resource Application Failure due to Abis Congestion
(Assigned by UL) .............................................................. 98
Figure 45 – Resource Application Failure due to RR Congestion
(Assigned by UL) .............................................................. 99
Figure 46 – Resource Application Failure due to UPPB-DSP
Channel Congestion (Assigned by UL).................................. 99

264 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B - Figures

Figure 47 – Successful Resource Application (Assigned by UL)


................................................................................... 100
Figure 48 – Successful Activation and Connection................ 102
Figure 49 – Resource Application Failure due to Abis Congestion
(Resource Adjustment).................................................... 103
Figure 50 – Resource Application Failure due to RR Congestion
(Resource Adjustment).................................................... 104
Figure 51 – Resource Application Failure due to UPPB-DSP
Channel Congestion (Resource Adjustment) ....................... 105
Figure 52 – Successful Resource Application (Resource
Adjustment) .................................................................. 106
Figure 53 – Release Request due to Flush LL ...................... 109
Figure 54 – Release Request due to Suspend Request.......... 109
Figure 55 – Release Request due to PDCH REL.................... 110
Figure 56 – Release Request due to Normal Release Request by
MAC ............................................................................. 110
Figure 57 – Release Request due to Abnormal Release Request
by MAC ......................................................................... 111
Figure 58 – Release Request due to NSVC Unavailability....... 111
Figure 59 – Release Request due to BVC Unavailability......... 112
Figure 60 – Release Request due to Other Reasons ............. 112
Figure 61 - DL GPRS resource request success.................... 113
Figure 62 - Resource Assignment Success .......................... 114
Figure 63 – Release DL GPRS TBF ..................................... 115
Figure 64 - Channel Request ............................................ 144
Figure 65 - Packet Channel Request .................................. 145
Figure 66 – UL Assignment Request (DL GPRS TBF already
established)................................................................... 146
Figure 67 - Channel Requests on CCCH due to One Phase Access
................................................................................... 146
Figure 68 - Packet Channel Requests on CCCH due to One Phase
Access .......................................................................... 146
Figure 69 - Channel Request due to Single Block Packet Access
................................................................................... 147
Figure 70 - Channel Request due to Response Paging .......... 148
Figure 71 - Channel Requests due to Cell Update ................ 148
Figure 72 - Channel Requests due to Mobile Management .... 149
Figure 73 - Channel Requests on CCCH due to Two Phase Access
................................................................................... 149
Figure 74 - Packet Channel Requests on PCCCH due to Two
Phase Access ................................................................. 150

Confidential and Proprietary Information of ZTE CORPORATION 265


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Figure 75 - Packet Channel Requests on PCCCH due to Short


Access .......................................................................... 150
Figure 76 - DB Resource Requests Failure due to Abis Congestion
(CCCH) ......................................................................... 151
Figure 77 - DB resource Requests Failure due to Abis Congestion
(PCCCH) ....................................................................... 151
Figure 78 - DB resource Requests Failure due to Abis Congestion
(DL GPRS TBF already Established) ................................... 151
Figure 79 - DB Resource Requests Failure due to rr Congestion
(CCCH) ......................................................................... 152
Figure 80 - DB resource Requests Failure due to rr Congestion
(PCCCH) ....................................................................... 152
Figure 81 - DB resource Requests Failure due to Abis Congestion
(DL GPRS TBF already Established) ................................... 153
Figure 82 - DB Resource Requests Failure due to UPPB-DSP
channel Congestion (CCCH) ............................................. 153
Figure 83 - DB resource Requests Failure due to Abis Congestion
(PCCCH) ....................................................................... 154
Figure 84 - DB resource Requests Failure due to DPPB-DSP
Congestion (DL GPRS TBF already Established)................... 154
Figure 85 - DB Resource Request Successes....................... 155
Figure 86 - DB resource Request Successes ....................... 155
Figure 87 - Channel Request Successes on CCCH due to One
Phase Access ................................................................. 156
Figure 88 - Packet Channel Request Successes on CCCH due to
One Phase Access........................................................... 156
Figure 89 - Channel Requests Successes due to Single Block
Packet Access ................................................................ 157
Figure 90 - DB Resource Request Successes due to Response
Paging .......................................................................... 157
Figure 91 - DB Resource Request Successes due to Cell Update
................................................................................... 158
Figure 92 - DB Resource Request Successes due to Mobile
Management (PCCCH)..................................................... 158
Figure 93 - DB Resource Request Successes due to Two Phase
Access (CCCH) ............................................................... 159
Figure 94 - DB Resource Request Successes on PCCCH due to
Two Phase Access........................................................... 159
Figure 95 - DB Resource Request Successes due to Short Access
(PCCCH) ....................................................................... 160
Figure 96 - UL GPRS TBF Establishment on PCCCH/CCCH ..... 163
Figure 97 - UL One-Phase-Access Resource Assignment
Successes ..................................................................... 164

266 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B - Figures

Figure 98 - UL Two-Phase-Access Single Block Assignment


Successes ..................................................................... 164
Figure 99 - DB Resource Requests Failure due to Abis Congestion
(Resource Request) ........................................................ 173
Figure 100 - DB Resource Requests Failure due to rr Congestion
(2) ............................................................................... 174
Figure 101 - DB Resource Requests Failure due to UPPB-DSP
channel Congestion (Resource Request)............................. 175
Figure 102 - DB Resource Requests Successes (Resource
Request) ....................................................................... 175
Figure 103 - DB Resource Requests Successes (Resource
Request) ....................................................................... 176
Figure 104 - UL GPRS resource request success .................. 181
Figure 105 - Resource Assignment Success ........................ 182
Figure 106 - Release UL GPRS TBF .................................... 183
Figure 107 - EGPRS Channel Request ................................ 190
Figure 108 - EGPRS Packet Channel Request ...................... 191
Figure 109 - EGPRS Channel Requests on CCCH due to One
Phase Access ................................................................. 192
Figure 110 - EGPRS Packet Channel Requests on CCCH due to
One Phase Access........................................................... 192
Figure 111 - EGPRS Channel Requests on CCCH due to Two
Phase Access ................................................................. 193
Figure 112 - EGPRS Packet Channel Requests on PCCCH due to
Two Phase Access ........................................................... 194
Figure 113 - EGPRS Channel Requests on CCCH due to Short
Access .......................................................................... 194
Figure 114 - EGPRS Packet Channel Requests on PCCCH due to
Two Phase Access ........................................................... 195
Figure 115 - DB Resource Requests Failure due to Abis
Congestion (EGPRS) ....................................................... 195
Figure 116 - DB Resource Requests Failure due to rr Congestion
(EGPRS)........................................................................ 196
Figure 117 - DB Resource Requests Failure due to UPPB-DSP
channel Congestion (EGPRS)............................................ 197
Figure 118 - DB Resource Request Successes (EGPRS) ........ 197
Figure 119 - DB Resource Request Successes on CCCH due to
One Phase Access........................................................... 198
Figure 120 - DB Resource Request Successes on PCCCH due to
One Phase Access........................................................... 198
Figure 121 - EGPRS DB Resource Request Successes due to Two
Phase Access (CCCH) ...................................................... 200

Confidential and Proprietary Information of ZTE CORPORATION 267


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

Figure 122 - DB Resource Request Successes on PCCCH due to


Two Phase Access........................................................... 200
Figure 123 - EGPRS DB Resource Request Successes due to
Short Access (CCCH) ...................................................... 201
Figure 124 - EGPRS DB Resource Request Successes due to
Short Access (PCCCH)..................................................... 201
Figure 125 - UL EGPRS resource request success ................ 220
Figure 126 - Release UL EGPRS TBF .................................. 222
Figure 127 - PAGING PS Process....................................... 224
Figure 128 - PAGING CS Process ...................................... 225
Figure 129 - FLUSH-LL Process......................................... 225
Figure 130 - BVC Blocking Process .................................... 226
Figure 131 - BVC Unblocking Process ................................ 227
Figure 132 - BVC Reset Process ........................................ 228
Figure 133 - Perform Locating Process ............................... 229
Figure 134 - Receive FLUSH-LL for UL & DL TBF .................. 231
Figure 135 - Receive FLUSH-LL for DL TBF ......................... 232
Figure 136 - Receive FLUSH-LL for UL TBF ......................... 232
Figure 137 - Intra-cell handover ....................................... 238
Figure 138 - Inter-cell Handover Controlled by BSC ............. 239
Figure 139 - BSC Receives Radio Link Failure Message Reported
by BTS.......................................................................... 241
Figure 140 - Inter-cell Handover Failure............................. 242
Figure 141 - Intra-cell Handover Failure............................. 242
Figure 142 - Channel Activation Measurement Point ............ 243
Figure 143 - TCH/F Channel Assignment Measurement Point. 244
Figure 144 - THoOutGo Timeout ....................................... 246
Figure 145 - Channel Assignment Measurement Point .......... 247
Figure 146 - BSC Receives the measurement report submitted
by BTS.......................................................................... 248

268 Confidential and Proprietary Information of ZTE CORPORATION


Tables

Table 1 – Manual Summary ...................................................i


Table 2 - Typographical Conventions..................................... iii
Table 3 - Mouse Operation Conventions ................................ iv
Table 4 – Usage Explanation of the Hazardous Substances in
ZXG10 iBSC (V6.20.10)....................................................... v
Table 5 - Sub Cell Statistics Counters ....................................7
Table 6 - MS TA Measurement Counters ............................... 41
Table 7 - SAPI3 Measurement Counters ............................... 55
Table 8 - UL and DL PACCH Statistics Counters ..................... 69
TA B L E 9 - DL G PR S D ATA T B F S TAT I S T I C S C O U N T E R S ........... 85
TA B L E 10 - DL EG PR S D ATA T BF S TAT I S T I C S C O U N T E R S ...... 117
Table 11 - UL GPRS Data TBF statistics Counter .................. 139
Table 12 - UL EGPRS Data TBF statistics Counter................. 185
Table 13 - BSSGP Flow Statistics Counter ........................... 223
Table 14 - TRX measurement counter ................................ 235

Confidential and Proprietary Information of ZTE CORPORATION 269


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

This page is intentionally blank.

270 Confidential and Proprietary Information of ZTE CORPORATION


Index

C901130001 ...................... 10 C901130051 ...................... 35


C901130002 ...................... 10 C901130052 ...................... 35
C901130003 ...................... 11 C901130053 ...................... 36
C901130004 ...................... 11 C901130054 ...................... 36
C901130005 ...................... 11 C901130055 ...................... 37
C901130006 ...................... 12 C901130056 ...................... 37
C901130007 ...................... 12 C901130057 ...................... 38
C901130008 ...................... 13 C901130058 ...................... 38
C901130009 ...................... 13 C901130059 ...................... 39
C901130010 ...................... 14 C901130060 ...................... 39
C901130011 ...................... 14 C901140001 ...................... 42
C901130012 ...................... 15 C901140002 ...................... 43
C901130013 ...................... 15 C901140003 ...................... 43
C901130014 ...................... 15 C901140004 ...................... 43
C901130015 ...................... 16 C901140005 ...................... 44
C901130016 ...................... 16 C901140006 ...................... 44
C901130017 ...................... 17 C901140007 ...................... 44
C901130018 ...................... 18 C901140008 ...................... 45
C901130019 ...................... 18 C901140009 ...................... 45
C901130020 ...................... 19 C901140010 ...................... 45
C901130021 ...................... 19 C901140011 ...................... 46
C901130022 ...................... 20 C901140012 ...................... 46
C901130023 ...................... 20 C901140013 ...................... 46
C901130024 ...................... 21 C901140014 ...................... 47
C901130025 ...................... 21 C901140015 ...................... 47
C901130026 ...................... 22 C901140016 ...................... 47
C901130027 ...................... 22 C901140017 ...................... 48
C901130028 ...................... 23 C901140018 ...................... 48
C901130029 ...................... 23 C901140019 ...................... 48
C901130030 ...................... 24 C901140020 ...................... 49
C901130031 ...................... 24 C901140021 ...................... 49
C901130032 ...................... 25 C901140022 ...................... 49
C901130033 ...................... 25 C901140023 ...................... 50
C901130034 ...................... 26 C901140024 ...................... 50
C901130035 ...................... 26 C901140025 ...................... 50
C901130036 ...................... 27 C901140026 ...................... 51
C901130037 ...................... 27 C901140027 ...................... 51
C901130038 ...................... 28 C901140028 ...................... 51
C901130039 ...................... 28 C901140029 ...................... 52
C901130040 ...................... 29 C901140030 ...................... 52
C901130041 ...................... 30 C901140031 ...................... 52
C901130042 ...................... 30 C901140032 ...................... 53
C901130043 ...................... 31 C901140033 ...................... 53
C901130044 ...................... 31 C901150001 ...................... 56
C901130045 ...................... 32 C901150002 ...................... 57
C901130046 ...................... 32 C901150004 ...................... 58
C901130047 ...................... 33 C901150005 ...................... 58
C901130048 ...................... 33 C901150006 ...................... 58
C901130049 ...................... 34 C901150007 ...................... 59
C901130050 ...................... 34 C901150009 ...................... 60

Confidential and Proprietary Information of ZTE CORPORATION 271


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901150010 ...................... 60 C901170025.......................99


C901150011 ...................... 60 C901170026..................... 100
C901150012 ...................... 61 C901170027..................... 100
C901150014 ...................... 61 C901170028..................... 101
C901150015 ...................... 61 C901170029..................... 101
C901150016 ...................... 62 C901170030..................... 101
C901150017 ...................... 64 C901170031..................... 102
C901150018 ...................... 65 C901170032..................... 102
C901150019 ...................... 65 C901170033..................... 103
C901150020 ...................... 65 C901170036..................... 103
C901150021 ...................... 66 C901170037..................... 103
C901150022 ...................... 66 C901170038..................... 104
C901150023 ...................... 66 C901170039..................... 105
C901150024 ...................... 67 C901170040..................... 106
C901150025 ...................... 67 C901170041..................... 106
C901160001 ...................... 70 C901170042..................... 107
C901160002 ...................... 71 C901170043..................... 107
C901160003 ...................... 71 C901170044..................... 108
C901160004 ...................... 72 C901170045..................... 108
C901160005 ...................... 73 C901170046..................... 108
C901160006 ...................... 73 C901170047..................... 108
C901160007 ...................... 74 C901170048..................... 109
C901160008 ...................... 74 C901170049..................... 109
C901160009 ...................... 75 C901170050..................... 110
C901160010 ...................... 75 C901170051..................... 110
C901160011 ...................... 76 C901170052..................... 111
C901160012 ...................... 77 C901170053..................... 112
C901160013 ...................... 77 C901170054..................... 112
C901160014 ...................... 78 C901170055..................... 113
C901160017 ...................... 78 C901170056..................... 113
C901160018 ...................... 79 C901170057..................... 113
C901160019 ...................... 79 C901170058..................... 114
C901160020 ...................... 79 C901170059..................... 114
C901160021 ...................... 80 C901180002..................... 120
C901160022 ...................... 81 C901180003..................... 120
C901160023 ...................... 81 C901180004..................... 121
C901160024 ...................... 82 C901180005..................... 121
C901160025 ...................... 82 C901180007..................... 121
C901160026 ...................... 83 C901180008..................... 121
C901160027 ...................... 84 C901180009..................... 122
C901170002 ...................... 88 C901180010..................... 123
C901170003 ...................... 88 C901180011..................... 123
C901170004 ...................... 89 C901180012..................... 123
C901170005 ...................... 89 C901180013..................... 124
C901170007 ...................... 89 C901180014..................... 124
C901170008 ...................... 90 C901180015..................... 125
C901170009 ...................... 91 C901180016..................... 125
C901170010 ...................... 92 C901180017..................... 125
C901170011 ...................... 93 C901180018..................... 126
C901170012 ...................... 93 C901180019..................... 126
C901170013 ...................... 94 C901180020..................... 126
C901170014 ...................... 95 C901180023..................... 126
C901170015 ...................... 95 C901180024..................... 127
C901170016 ...................... 96 C901180025..................... 127
C901170017 ...................... 96 C901180026..................... 128
C901170018 ...................... 97 C901180027..................... 128
C901170019 ...................... 97 C901180028..................... 128
C901170020 ...................... 97 C901180029..................... 129
C901170023 ...................... 97 C901180030..................... 129
C901170024 ...................... 98 C901180031..................... 130

272 Confidential and Proprietary Information of ZTE CORPORATION


Index

C901180032 .................... 130 C901190044 .................... 167


C901180033 .................... 130 C901190045 .................... 167
C901180036 .................... 130 C901190046 .................... 168
C901180037 .................... 131 C901190047 .................... 168
C901180038 .................... 131 C901190048 .................... 168
C901180039 .................... 132 C901190051 .................... 168
C901180040 .................... 132 C901190052 .................... 169
C901180041 .................... 133 C901190053 .................... 169
C901180042 .................... 133 C901190054 .................... 170
C901180043 .................... 134 C901190055 .................... 170
C901180044 .................... 134 C901190056 .................... 171
C901180045 .................... 134 C901190057 .................... 171
C901180046 .................... 134 C901190058 .................... 172
C901180047 .................... 135 C901190059 .................... 172
C901180048 .................... 135 C901190060 .................... 172
C901180049 .................... 135 C901190061 .................... 172
C901180050 .................... 136 C901190062 .................... 173
C901180051 .................... 136 C901190064 .................... 173
C901180052 .................... 136 C901190065 .................... 173
C901180053 .................... 137 C901190066 .................... 174
C901180054 .................... 137 C901190067 .................... 175
C901190002 .................... 144 C901190068 .................... 176
C901190003 .................... 144 C901190069 .................... 176
C901190004 .................... 145 C901190070 .................... 177
C901190005 .................... 145 C901190071 .................... 177
C901190006 .................... 145 C901190072 .................... 178
C901190007 .................... 146 C901190073 .................... 178
C901190008 .................... 147 C901190074 .................... 178
C901190009 .................... 147 C901190075 .................... 178
C901190010 .................... 148 C901190076 .................... 179
C901190011 .................... 148 C901190077 .................... 179
C901190012 .................... 149 C901190078 .................... 179
C901190013 .................... 150 C901190079 .................... 180
C901190015 .................... 150 C901190080 .................... 180
C901190016 .................... 152 C901190081 .................... 180
C901190017 .................... 153 C901190082 .................... 181
C901190018 .................... 154 C901190083 .................... 181
C901190019 .................... 155 C901190084 .................... 181
C901190020 .................... 156 C901190085 .................... 182
C901190021 .................... 157 C901190086 .................... 182
C901190022 .................... 157 C901190087 .................... 183
C901190023 .................... 158 C901200002 .................... 190
C901190024 .................... 159 C901200003 .................... 190
C901190025 .................... 159 C901200004 .................... 191
C901190026 .................... 160 C901200005 .................... 191
C901190027 .................... 161 C901200006 .................... 191
C901190028 .................... 161 C901200007 .................... 192
C901190029 .................... 162 C901200008 .................... 192
C901190030 .................... 162 C901200009 .................... 193
C901190031 .................... 162 C901200010 .................... 193
C901190032 .................... 163 C901200011 .................... 193
C901190033 .................... 163 C901200012 .................... 193
C901190034 .................... 163 C901200013 .................... 194
C901190035 .................... 164 C901200015 .................... 195
C901190038 .................... 164 C901200016 .................... 196
C901190039 .................... 165 C901200017 .................... 196
C901190040 .................... 165 C901200018 .................... 197
C901190041 .................... 166 C901200019 .................... 198
C901190042 .................... 166 C901200020 .................... 198
C901190043 .................... 166 C901200021 .................... 199

Confidential and Proprietary Information of ZTE CORPORATION 273


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume III)

C901200022 .....................199 C901200087..................... 221


C901200023 .....................199 C901210001..................... 224
C901200024 .....................199 C901210002..................... 225
C901200025 .....................200 C901210003..................... 225
C901200026 .....................201 C901210004..................... 226
C901200027 .....................201 C901210005..................... 226
C901200028 .....................202 C901210006..................... 226
C901200029 .....................202 C901210007..................... 227
C901200030 .....................203 C901210008..................... 227
C901200031 .....................203 C901210009..................... 227
C901200032 .....................204 C901210010..................... 228
C901200033 .....................204 C901210011..................... 228
C901200034 .....................204 C901210012..................... 228
C901200035 .....................205 C901210013..................... 229
C901200038 .....................205 C901210014..................... 229
C901200039 .....................205 C901210015..................... 230
C901200040 .....................206 C901210016..................... 230
C901200041 .....................206 C901210017..................... 230
C901200042 .....................206 C901210018..................... 231
C901200043 .....................207 C901210019..................... 231
C901200044 .....................207 C901210020..................... 232
C901200045 .....................208 C901210021..................... 232
C901200046 .....................208 C901210022..................... 233
C901200047 .....................208 C901210023..................... 233
C901200048 .....................208 C901230001..................... 238
C901200051 .....................209 C901230002..................... 238
C901200052 .....................209 C901230003..................... 238
C901200053 .....................210 C901230004..................... 239
C901200054 .....................210 C901230005..................... 239
C901200055 .....................210 C901230006..................... 240
C901200056 .....................211 C901230007..................... 240
C901200057 .....................211 C901230008..................... 240
C901200058 .....................212 C901230009..................... 241
C901200059 .....................212 C901230010..................... 241
C901200060 .....................212 C901230011..................... 241
C901200061 .....................213 C901230012..................... 242
C901200062 .....................213 C901230013..................... 243
C901200064 .....................213 C901230014..................... 243
C901200065 .....................213 C901230015..................... 244
C901200066 .....................214 C901230016..................... 244
C901200067 .....................214 C901230017..................... 244
C901200068 .....................215 C901230018..................... 245
C901200069 .....................215 C901230019..................... 245
C901200070 .....................215 C901230020..................... 245
C901200071 .....................216 C901230021..................... 246
C901200072 .....................216 C901230022..................... 246
C901200073 .....................217 C901230023..................... 247
C901200074 .....................217 C901230024..................... 247
C901200075 .....................217 C901230025..................... 247
C901200076 .....................217 C901230026..................... 248
C901200077 .....................218 C901230027..................... 248
C901200078 .....................218 C901230028..................... 248
C901200079 .....................218 C901230029..................... 249
C901200080 .....................219 C901230030..................... 249
C901200081 .....................219 C901230031..................... 249
C901200082 .....................219 C901230032..................... 249
C901200083 .....................220 C901230033..................... 250
C901200084 .....................220 C901230034..................... 250
C901200085 .....................221 C901230035..................... 250
C901200086 .....................221 C901230036..................... 250

274 Confidential and Proprietary Information of ZTE CORPORATION


Index

C901230037 .................... 251 C901230050 .................... 254


C901230038 .................... 251 C901230051 .................... 254
C901230039 .................... 251 C901230052 .................... 255
C901230040 .................... 251 C901230053 .................... 255
C901230041 .................... 252 C901230054 .................... 255
C901230042 .................... 252 C901230055 .................... 255
C901230043 .................... 252 C901230056 .................... 256
C901230044 .................... 253 C901230057 .................... 256
C901230045 .................... 253 C901230058 .................... 256
C901230046 .................... 253 C901230059 .................... 256
C901230047 .................... 253 C901230060 .................... 257
C901230048 .................... 254 C901230061 .................... 257
C901230049 .................... 254 C901230062 .................... 257

Confidential and Proprietary Information of ZTE CORPORATION 275


ZXG10 iBSC
Base Station Controller
Performance Counter Reference (Volume IV)

Version 6.20.10

ZTE CORPORATION
ZTE Plaza, Keji Road South,
Hi-Tech Industrial Park,
Nanshan District, Shenzhen,
P. R. China
518057
Tel: (86) 755 26771900 800-9830-9830
Fax: (86) 755 26772236
URL: http://support.zte.com.cn
E-mail: doc@zte.com.cn
This page is intentionally blank.
Contents

About This Manual ............................................................ i


Purpose ................................................................................ i
Intended Audience ................................................................. i
Prerequisite Skill and Knowledge .............................................. i
What Is in This Manual ........................................................... i
Related Documentation.......................................................... ii
Conventions ......................................................................... ii
How to Get in Touch ............................................................. iv

Declaration of RoHS Compliance..................................... v

Chapter 1.......................................................................... 1

Timeslot Measurement .................................................... 1


Overview ............................................................................. 1
Timeslot measurement counter index....................................... 1
C901240001 ........................................................................ 3
C901240002 ........................................................................ 3
C901240003 ........................................................................ 4
C901240004 ........................................................................ 4
C901240005 ........................................................................ 4
C901240006 ........................................................................ 5
C901240007 ........................................................................ 5
C901240008 ........................................................................ 5
C901240009 ........................................................................ 6
C901240010 ........................................................................ 6
C901240011 ........................................................................ 6
C901240012 ........................................................................ 7
C901240013 ........................................................................ 7
C901240014 ........................................................................ 7
C901240015 ........................................................................ 8
C901240016 ........................................................................ 8
C901240017 ........................................................................ 8
C901240018........................................................................ 9
C901240019........................................................................ 9
C901240020........................................................................ 9
C901240021.......................................................................10
C901240022.......................................................................10
C901240023.......................................................................11
C901240024.......................................................................12
C901240025.......................................................................12
C901240026.......................................................................13
C901240027.......................................................................13
C901240028.......................................................................13
C901240029.......................................................................14
C901240030.......................................................................14
C901240031.......................................................................15
C901240032.......................................................................15
C901240033.......................................................................15
C901240034.......................................................................16
C901240035.......................................................................16
C901240036.......................................................................16
C901240037.......................................................................16
C901240038.......................................................................18
C901240039.......................................................................19
C901240040.......................................................................19
C901240041.......................................................................20
C901240042.......................................................................20
C901240043.......................................................................20
C901240044.......................................................................21

Chapter 2........................................................................ 23

SDCCH Measurement ..................................................... 23


Overview ...........................................................................23
SDCCH measurement Counter Index ......................................25
C901250005.......................................................................25
C901250007.......................................................................26
C901250010.......................................................................26
C901250011.......................................................................27
C901250012.......................................................................27
C901250016.......................................................................27
C901250017.......................................................................28
C901250018 ...................................................................... 28
C901250019 ...................................................................... 29

Chapter 3........................................................................ 31

TCH/F Measurement...................................................... 31
Overview ........................................................................... 31
TCH/F Measurement Counter Index ....................................... 34
C901260002 ...................................................................... 38
C901260005 ...................................................................... 38
C901260007 ...................................................................... 39
C901260010 ...................................................................... 39
C901260011 ...................................................................... 40
C901260013 ...................................................................... 40
C901260016 ...................................................................... 41
C901260017 ...................................................................... 42
C901260018 ...................................................................... 42
C901260019 ...................................................................... 43
C901260021 ...................................................................... 44
C901260024 ...................................................................... 45
C901260026 ...................................................................... 45
C901260032 ...................................................................... 46
C901260033 ...................................................................... 46
C901260038 ...................................................................... 47
C901260044 ...................................................................... 47
C901260045 ...................................................................... 48
C901260050 ...................................................................... 48
C901260056 ...................................................................... 49
C901260057 ...................................................................... 49
C901260062 ...................................................................... 49
C901260065 ...................................................................... 50
C901260067 ...................................................................... 51
C901260068 ...................................................................... 51
C901260070 ...................................................................... 51
C901260073 ...................................................................... 52
C901260075 ...................................................................... 52
C901260081 ...................................................................... 52
C901260082 ...................................................................... 53
C901260087 ...................................................................... 53
C901260090 ...................................................................... 54
C901260092.......................................................................54
C901260093.......................................................................55
C901260094.......................................................................55
C901260095.......................................................................56
C901260096.......................................................................57
C901260097.......................................................................58
C901260098.......................................................................59
C901260099.......................................................................60
C901260100.......................................................................60
C901260101.......................................................................60
C901260102.......................................................................61
C901260103.......................................................................61
C901260104.......................................................................62
C901260105.......................................................................62
C901260106.......................................................................63
C901260107.......................................................................63
C901260108.......................................................................64
C901260109.......................................................................64
C901260110.......................................................................65
C901260111.......................................................................65
C901260112.......................................................................66
C901260113.......................................................................66
C901260114.......................................................................66
C901260115.......................................................................67
C901260116.......................................................................67
C901260117.......................................................................68
C901260118.......................................................................68
C901260119.......................................................................69
C901260120.......................................................................69
C901260121.......................................................................69
C901260122.......................................................................70
C901260123.......................................................................70
C901260124.......................................................................71
C901260125.......................................................................71
C901260126.......................................................................72
C901260127.......................................................................72
C901260128.......................................................................72
C901260129.......................................................................73
C901260130.......................................................................73
C901260131 ...................................................................... 74
C901260132 ...................................................................... 74
C901260133 ...................................................................... 75
C901260134 ...................................................................... 75
C901260135 ...................................................................... 75

Chapter 4........................................................................ 77

TCH/H Measurement ..................................................... 77


Overview ........................................................................... 77
TCH/H Measurement Counter Index ....................................... 77
C901270002 ...................................................................... 81
C901270005 ...................................................................... 82
C901270007 ...................................................................... 82
C901270008 ...................................................................... 83
C901270010 ...................................................................... 83
C901270011 ...................................................................... 84
C901270012 ...................................................................... 84
C901270013 ...................................................................... 85
C901270016 ...................................................................... 86
C901270017 ...................................................................... 86
C901270018 ...................................................................... 87
C901270019 ...................................................................... 87
C901270021 ...................................................................... 87
C901270024 ...................................................................... 88
C901270026 ...................................................................... 88
C901270027 ...................................................................... 89
C901270032 ...................................................................... 89
C901270033 ...................................................................... 90
C901270038 ...................................................................... 90
C901270039 ...................................................................... 90
C901270044 ...................................................................... 91
C901270045 ...................................................................... 91
C901270050 ...................................................................... 92
C901270051 ...................................................................... 92
C901270056 ...................................................................... 93
C901270057 ...................................................................... 93
C901270062 ...................................................................... 94
C901270065 ...................................................................... 94
C901270067 ...................................................................... 95
C901270068.......................................................................95
C901270070.......................................................................95
C901270073.......................................................................96
C901270075.......................................................................96
C901270076.......................................................................97
C901270081.......................................................................97
C901270082.......................................................................98
C901270087.......................................................................98
C901270090.......................................................................98
C901270092.......................................................................99
C901270093.......................................................................99
C901270094..................................................................... 100
C901270095..................................................................... 100
C901270096..................................................................... 101
C901270097..................................................................... 101
C901270098..................................................................... 101
C901270099..................................................................... 102
C901270100..................................................................... 102
C901270101..................................................................... 103
C901270102..................................................................... 103
C901270103..................................................................... 104
C901270104..................................................................... 104
C901270105..................................................................... 104
C901270106..................................................................... 105
C901270107..................................................................... 105
C901270108..................................................................... 106
C901270109..................................................................... 106
C901270110..................................................................... 107
C901270111..................................................................... 107
C901270112..................................................................... 108
C901270113..................................................................... 108
C901270114..................................................................... 108
C901270115..................................................................... 109
C901270116..................................................................... 109
C901270117..................................................................... 110
C901270118..................................................................... 110
C901270119..................................................................... 111
C901270120..................................................................... 111
C901270121..................................................................... 111
C901270122 .................................................................... 112
C901270123 .................................................................... 112
C901270124 .................................................................... 113
C901270125 .................................................................... 113
C901270126 .................................................................... 114
C901270127 .................................................................... 114
C901270128 .................................................................... 115
C901270129 .................................................................... 115
C901270130 .................................................................... 115
C901270131 .................................................................... 116
C901270132 .................................................................... 116
C901270133 .................................................................... 117
C901270134 .................................................................... 117
C901270135 .................................................................... 118

Chapter 5...................................................................... 119

Abis Interface Message Counter Measurement..........119


Overview ......................................................................... 119
Abis Interface Message Counter Index ................................. 120
C901280001 .................................................................... 123
C901280002 .................................................................... 123
C901280003 .................................................................... 124
C901280004 .................................................................... 124
C901280005 .................................................................... 124
C901280006 .................................................................... 125
C901280007 .................................................................... 125
C901280008 .................................................................... 125
C901280009 .................................................................... 126
C901280010 .................................................................... 126
C901280011 .................................................................... 126
C901280012 .................................................................... 127
C901280013 .................................................................... 127
C901280014 .................................................................... 127
C901280015 .................................................................... 128
C901280016 .................................................................... 128
C901280017 .................................................................... 128
C901280018 .................................................................... 129
C901280019 .................................................................... 129
C901280020 .................................................................... 130
C901280021..................................................................... 130
C901280022..................................................................... 130
C901280023..................................................................... 131
C901280024..................................................................... 131
C901280025..................................................................... 131
C901280026..................................................................... 132
C901280027..................................................................... 132
C901280028..................................................................... 133
C901280029..................................................................... 133
C901280030..................................................................... 133
C901280031..................................................................... 134
C901280032..................................................................... 134
C901280033..................................................................... 135
C901280034..................................................................... 135
C901280035..................................................................... 135
C901280036..................................................................... 136
C901280037..................................................................... 136
C901280038..................................................................... 136
C901280039..................................................................... 137
C901280040..................................................................... 137
C901280041..................................................................... 137
C901280042..................................................................... 138
C901280043..................................................................... 138
C901280044..................................................................... 138
C901280045..................................................................... 139
C901280046..................................................................... 139
C901280047..................................................................... 139
C901280048..................................................................... 140
C901280049..................................................................... 140
C901280050..................................................................... 140
C901280051..................................................................... 141
C901280052..................................................................... 141
C901280053..................................................................... 141
C901280054..................................................................... 141
C901280055..................................................................... 142
C901280056..................................................................... 142
C901280057..................................................................... 142
C901280061..................................................................... 143
C901280062..................................................................... 143
C901280063 .................................................................... 143
C901280064 .................................................................... 144
C901280065 .................................................................... 144
C901280066 .................................................................... 144
C901280067 .................................................................... 145
C901280068 .................................................................... 145
C901280069 .................................................................... 145
C901280070 .................................................................... 146
C901280071 .................................................................... 146
C901280072 .................................................................... 146
C901280073 .................................................................... 147
C901280074 .................................................................... 147
C901280075 .................................................................... 147
C901280076 .................................................................... 148
C901280077 .................................................................... 148
C901280078 .................................................................... 148
C901280079 .................................................................... 149
C901280080 .................................................................... 149
C901280081 .................................................................... 149
C901280082 .................................................................... 150
C901280083 .................................................................... 150
C901280084 .................................................................... 150
C901280085 .................................................................... 151
C901280086 .................................................................... 151
C901280087 .................................................................... 151
C901280088 .................................................................... 152
C901280089 .................................................................... 152
C901280090 .................................................................... 152
C901280091 .................................................................... 153
C901280092 .................................................................... 153
C901280093 .................................................................... 153
C901280094 .................................................................... 154
C901280095 .................................................................... 154
C901280096 .................................................................... 154
C901280097 .................................................................... 155
C901280098 .................................................................... 155
C901280099 .................................................................... 155
C901280100 .................................................................... 156
C901280101 .................................................................... 156
C901280102..................................................................... 156

Chapter 6......................................................................157

Gb Message Statistics (BVC Cell) ................................157


Overview ......................................................................... 157
Gb Message Statistics Counter Index.................................... 157
C901290001..................................................................... 159
C901290002..................................................................... 159
C901290003..................................................................... 160
C901290004..................................................................... 160
C901290005..................................................................... 161
C901290006..................................................................... 161
C901290007..................................................................... 161
C901290008..................................................................... 162
C901290009..................................................................... 162
C901290010..................................................................... 163
C901290011..................................................................... 163
C901290012..................................................................... 163
C901290013..................................................................... 163
C901290014..................................................................... 164
C901290015..................................................................... 164
C901290016..................................................................... 165
C901290017..................................................................... 165
C901290018..................................................................... 165
C901290019..................................................................... 166
C901290020..................................................................... 166
C901290021..................................................................... 166
C901290022..................................................................... 167
C901290023..................................................................... 167
C901290024..................................................................... 167
C901290025..................................................................... 167
C901290026..................................................................... 168
C901290027..................................................................... 168
C901290028..................................................................... 168
C901290029..................................................................... 169
C901290030..................................................................... 169
C901290031..................................................................... 169
C901290032..................................................................... 170
C901290033..................................................................... 170
C901290034 .................................................................... 170
C901290035 .................................................................... 171
C901290036 .................................................................... 171

Appendix A ................................................................... 173

Abbreviations ............................................................... 173

Appendix B ................................................................... 177

Figures.......................................................................... 177

Tables ........................................................................... 179

Index ............................................................................ 181


This page is intentionally blank.
About This Manual

Purpose
This manual provides procedures and guidelines that support the
operation of the ZXG10 iBSC (V6.20.10).

Intended Audience
This manual is intended for engineers and technicians who
perform operation activities on the ZXG10 iBSC (V6.20.10).

Prerequisite Skill and Knowledge


To use this manual effectively, users should have a general
understanding of wireless telecommunications technology.
Familiarity with the following is helpful:
„ ZXG10 system and its various components
„ GSM BSS components and processes
„ Local operating procedures

What Is in This Manual


This manual contains the following sections:

TABLE 1 – M ANUAL SUMMARY

Section Summary
Chapter 1, Timeslot Introduces the detailed information about
Measurement counters related to timeslot measurement.
Chapter 2, SDCCH Introduces the detailed information about
Measurement counters related to SDCCH measurement.
Chapter 3, TCH/F Introduces the detailed information about
Measurement counters related to TCH/F measurement.
Chapter 4, TCH/H Introduces the detailed information about

Confidential and Proprietary Information of ZTE CORPORATION i


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Section Summary
Measurement counters related to TCH/H measurement.

Chapter 5, Abis Introduces the detailed information about


Interface Message counters related to Abis interface message
Counter Measurement counter measurement.
Chapter 6, Gb Message Introduces the detailed information about
Statistics counters related to Gb message statistics.
Appendix A, Lists all the abbreviations used in this
Abbreviations manual.

Appendix B, Figures Lists all the figures and tables used in this
and Tables manual.

Index Index of terms and definitions appeared in


this manual.

Related Documentation
The following documentation is related to this manual:
„ ZXG10 iBSC (V6.20.10) Base Station Controller
Documentation Guide
„ ZXG10 iBSC (V6.20.10) Base Station Controller System
Description
„ ZXG10 iBSC (V6.20.10) Base Station Controller Hardware
Description
„ ZXG10 iBSC (V6.20.10) Base Station Controller Hardware
Installation Guide
„ ZXG10 iBSC (V6.20.10) Base Station Controller Routine
Maintenance
„ ZXG10 iBSC (V6.20.10) Base Station Controller Emergency
Maintenance
„ ZXG10 iBSC (V6.20.10) Base Station Controller
Troubleshooting
„ ZXG10 iBSC (V6.20.10) Base Station Controller KPI
Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem OMM
Software Installation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Initial
Configuration Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Feature
Configuration Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Radio
Parameters Reference

ii Confidential and Proprietary Information of ZTE CORPORATION


About This Manual

„ ZXG10 BSS (V6.20.10) Base Station Subsystem Ground


Parameters Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem MML
Command Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Signaling
Tracing Operation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Diagnosis
Test Operation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Alarm
Handling Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Notification
Handling Reference

Conventions
Typographical ZTE documents employ the following typographical conventions.
Conventions
TABLE 2 - TYPOGRAPHIC AL CONVENTIONS

Typeface Meaning
Italics References to other Manuals and documents.
“Quotes” Links on screens.
Bold Menus, menu options, function names, input
fields, radio button names, check boxes, drop-
down lists, dialog box names, window names.
CAPS Keys on the keyboard and buttons on screens
and company name.
Constant width Text that you type, program code, files and
directory names, and function names.
[] Optional parameters.
{} Mandatory parameters.
| Select one of the parameters that are delimited
by it.
Note: Provides additional information about a
certain topic.
Checkpoint: Indicates that a particular step needs
to be checked before proceeding further.
Tip: Indicates a suggestion or hint to make things
easier or more productive for the reader.

Mouse TABLE 3 - MOUSE OPERATION CONVENTIONS


Operation
Conventions Typeface Meaning

Confidential and Proprietary Information of ZTE CORPORATION iii


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Typeface Meaning
Click Refers to clicking the primary mouse button (usually
the left mouse button) once.
Double-click Refers to quickly clicking the primary mouse button
(usually the left mouse button) twice.
Right-click Refers to clicking the secondary mouse button
(usually the right mouse button) once.
Drag Refers to pressing and holding a mouse button and
moving the mouse.

How to Get in Touch


The following sections provide information on how to obtain
support for the documentation and the software.
Customer If you have problems, questions, comments, or suggestions
Support regarding your product, contact us by e-mail at
support@zte.com.cn. You can also call our customer support
center at (86) 755 26771900 and (86) 800-9830-9830.
Documentation ZTE welcomes your comments and suggestions on the quality
Support and usefulness of this document. For further questions,
comments, or suggestions on the documentation, you can
contact us by e-mail at doc@zte.com.cn; or you can fax your
comments and suggestions to (86) 755 26772236. You can also
browse our website at http://support.zte.com.cn, which contains
various interesting subjects like documentation, knowledge base,
forum and service request.

iv Confidential and Proprietary Information of ZTE CORPORATION


Declaration of RoHS
Compliance

To minimize the environmental impact and take more


responsibility to the earth we live, this document shall serve as
formal declaration that the ZXG10 iBSC (V6.20.10) Base Station
Controller manufactured by ZTE CORPORATION is in compliance
with the Directive 2002/95/EC of the European Parliament -
RoHS (Restriction of Hazardous Substances) with respect to the
following substances:
„ Lead (Pb)
„ Mercury (Hg)
„ Cadmium (Cd)
„ Hexavalent Chromium (Cr (VI))
„ PolyBrominated Biphenyls (PBB’s)
„ PolyBrominated Diphenyl Ethers (PBDE’s)
The usage of the above substances in ZXG10 iBSC (V6.20.10) is
explained in the Table 4.

TABLE 4 – USAGE EXPLANATION OF THE HAZ ARDOUS SUBSTANCES IN ZXG10


IBSC (V6.20.10)

Hazardous substances
Names of Parts
Pb Hg Cd Cr(VI) PBB’s PBDE’s

System × 0 0 0 0 0
Cables and Assembly 0 0 0 0 0 0
Auxiliary Equipment × × × × × ×

Table Explanation:
0: The usage of the substance in all of the components is less
than the allowed values given by 2002/95/EC standard.
×: The usage of the substance in at least one of the components
is beyond the allowed values given by 2002/95/EC standard.

Confidential and Proprietary Information of ZTE CORPORATION v


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

The ZXG10 iBSC (V6.20.10) Base Station Controller


manufactured by ZTE CORPORATION meet the requirements of
EU 2002/95/EC; however, some assemblies are customized to
client specifications. Addition of specialized, customer-specified
materials or processes, which do not meet the requirements of
EU 2002/95 /EC, may negate RoHS compliance of the assembly.
To guarantee compliance of the assembly, the need for
compliant product must be communicated to ZTE CORPORATION
in written form.
This declaration is issued based on our current level of
knowledge. Since conditions of use are outside our control, ZTE
CORPORATION makes no warranties, express or implied, and
assumes no liability in connection with the use of this
information.

vi Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1

Timeslot Measurement

This chapter contains detailed information about counters


related to TS measurement.

Overview
Timeslot counters are used to view the radio transceiver
environment of a MS in a particular timeslot, including the link
quality and strength in the timeslot. These data is sent to
Network side through measurement report. If signal strength in
some timeslots is weak, then it can be improved by changing
send and receive power.
The measurement takes cell as statistics unit.

Timeslot measurement counter


index
Table 5 lists counters related to timeslot measurement.

TABLE 5 - TIMESLOT MEASUREMENT COUNTER

Counter ID What It Counts


C901240001 Maximum value of UL RQ
C901240002 Minimum value of UL RQ
C901240003 Value of UL RQ
C901240004 Number of scans of UL RQ
C901240005 Maximum value of DL RQ
C901240006 Minimum value of DL RQ
C901240007 Value of DL RQ
C901240008 Number of scans of DL RQ

Confidential and Proprietary Information of ZTE CORPORATION 1


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Counter ID What It Counts


C901240009 Maximum value of received UL signal strength
C901240010 Minimum value of received UL signal strength
C901240011 Total value of received UL signal strength
C901240012 Number of received UL signal strength samples
C901240013 Maximum value of received DL signal strength
C901240014 Minimum value of received DL signal strength
C901240015 Total value of received DL signal strength
C901240016 Number of received DL signal strength samples
C901240017 Value of power scans of MS transmitting power
C901240018 Number of power scans of MS transmitting power
C901240019 Value of power scans of BTS power
C901240020 Number of power scans of BTS power
C901240021 Number of immediate assignment failure
C901240022 Number of assignment failure
C901240023 Number of handovers failure
C901240024 Maximum interference value
C901240025 Minimum interference value
C901240026 Interference value
Number of regular scanning and sampling of
C901240027
interference value
C901240028 Number of call drop
C901240029 Maximum value of path balance
C901240030 Minimum value of path balance
C901240031 Value of path balance
Number of regular scanning and sampling of path
C901240032
balance
C901240033 Value of UL loss
Number of regular scanning and sampling of UL
C901240034
loss
C901240035 Total value of DL loss
Number of regular scanning and sampling of DL
C901240036
loss
Number of drops due to the bad quality of UL
C901240037
receive
Number of drops due to the bad quality of DL
C901240038
receive
C901240039 Number of drops due to the low electric level of UL
C901240040 Number of drops due to the low electric level of DL
C901240041 Number of drops due to the TA too far

2 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Timeslot Measurement

Counter ID What It Counts


C901240042 Number of drops due to the other radio reasons
C901240043 The valid time of the used voice channel
C901240044 Number of activated voice channel

C901240001
Definition
Maximum UL RQ
Description
This counter counts Maximum UL RQ in the measurement report
of a timeslot in a cell.
Usage
This counter is used to find out the Maximum UL RQ in a
timeslot of a cell. It is one of the parameters that evaluate
timeslot radio environment.
Measurement
Point After BSC receives the measurement report from BTS, if UL RQ
in the report is bigger than the value in the counter, the UL RQ
in the counter is replaced. The measurement point is A, as
shown in Figure 1.

FIGURE 1 - BSC RECEIVES THE MEASUREMENT REPORT SUBMITTED BY BTS

Unit
NA

C901240002
Definition
Minimum UL RQ
Description
This counter counts Minimum UL RQ in the measurement report
of a timeslot in a cell.
Usage
This counter is used to find out the Minimum UL RQ in a timeslot
of a cell. It is one of the parameters that evaluate timeslot radio
environment.
Measurement
Point After BSC receives the measurement report from BTS, if UL RQ
in the report is less than the value in the counter, the UL RQ in
the counter is replaced. The measurement point is A, as shown
in Figure 1.
Unit
NA

Confidential and Proprietary Information of ZTE CORPORATION 3


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901240003
Definition
Description Total value of UL RQ
This counter counts the total value of UL RQ of a timeslot of a
Usage cell in the measurement report.
This counter is used to find out the Total value of UL RQ in a
timeslot of a cell. It is one of the parameters that evaluate
Measurement timeslot radio environment.
Point
After BSC receives the measurement report from BTS, the
counter accumulates UL RQ value for relevant timeslot. The
Unit measurement point is A, as shown in Figure 1.
NA

C901240004
Definition
Description Number of scans of UL RQ
This counter counts the number of times of sampling UL RQ of a
Usage timeslot in a cell.
This counter shows the frequency of sampling UL RQ of a
timeslot in a cell. It is one of the parameters that evaluate
Measurement timeslot radio environment.
Point
The counter increments after BSC receives the measurement
report from BTS. The measurement point is A, as shown in
Unit Figure 1.
Times

C901240005
Definition
Description Maximum value of DL RQ
This counter counts Maximum DL RQ in the measurement report
Usage of a timeslot in a cell.
This counter is used to find out the Maximum DL RQ in a
timeslot of a cell. It is one of the parameters that evaluate
Measurement timeslot radio environment.
Point
After BSC receives the measurement report from BTS, if DL RQ
in the report is bigger than the value in the counter, the DL RQ
is in the counter replaced. The measurement point is A, as
Unit shown in Figure 1.
NA

4 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Timeslot Measurement

C901240006
Definition
Description Minimum DL RQ
This counter counts Minimum DL RQ in the measurement report
Usage of a timeslot in a cell.
This counter is used to find out the Minimum DL RQ in a timeslot
of a cell. It is one of the parameters that evaluate timeslot radio
Measurement environment.
Point
After BSC receives the measurement report from BTS, if DL RQ
in the report is less than the value in the counter, the DL RQ in
the counter is replaced. The measurement point is A, as shown
Unit in Figure 1.
NA

C901240007
Definition
Description Total value of DL RQ
This counter counts the total value of DL RQ of a timeslot of a
Usage cell in the measurement report.
This counter is used to find out the Total value of DL RQ in a
timeslot of a cell. It is one of the parameters that evaluate
Measurement timeslot radio environment.
Point
After BSC receives the measurement report from BTS, the
counter accumulates DL RQ value for relevant timeslot. The
Unit measurement point is A, as shown in Figure 1.
NA

C901240008
Definition
Description Number of scans of DL RQ
This counter counts the number of times of sampling DL RQ of a
Usage timeslot in a cell.
This counter shows the frequency of sampling DL RQ of a
timeslot in a cell. It is one of the parameters that evaluate
Measurement timeslot radio environment.
Point
The counter increments after BSC receives the measurement
report from BTS. The measurement point is A, as shown in
Unit Figure 1.
Times

Confidential and Proprietary Information of ZTE CORPORATION 5


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901240009
Definition
Maximum value of received UL signal strength
Description
This counter counts Maximum value of received UL signal
strength in the measurement report of a timeslot in a cell.
Usage
This counter is used to find out the Maximum value of received
UL signal strength in a timeslot of a cell. It is one of the
parameters that evaluate timeslot radio environment.
Measurement
Point After BSC receives the measurement report from BTS, if
received UL signal strength in the report is bigger than the value
in the counter, the received UL signal strength in the counter is
replaced. The measurement point is A, as shown in Figure 1.
Unit
dBm

C901240010
Definition
Minimum value of received UL signal strength
Description
This counter counts Minimum value of received UL signal
strength in the measurement report of a timeslot in a cell.
Usage
This counter is used to find out the Minimum value of received
UL signal strength in a timeslot in a cell. It is one of the
parameters that evaluate timeslot radio environment.
Measurement
Point After BSC receives the measurement report from BTS, if the
value of received UL signal strength in the report is less than the
value in the counter, the received UL signal strength in the
counter is replaced. The measurement point is A, as shown in
Figure 1.
Unit
dBm

C901240011
Definition
Total value of received UL signal strength
Description
This counter counts the total value of received UL signal strength
of a timeslot of a cell in the measurement report.
Usage
This counter is used to find out the total value of received UL
signal strength in a timeslot in a cell. It is one of the parameters
that evaluate timeslot radio environment.
Measurement
Point After BSC receives the measurement report from BTS, the
counter accumulates UL reception strength value for relevant
timeslot. The measurement point is A, as shown in Figure 1.
Unit
dBm

6 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Timeslot Measurement

C901240012
Definition
Description Number of received UL signal strength samples
This counter counts the number of times of sampling UL signal
Usage strength in a timeslot in a cell.
This counter shows the frequency of sampling UL signal strength
in a timeslot in a cell. It is one of the parameters that evaluate
Measurement timeslot radio environment.
Point The counter increments after BSC receives the measurement
report from BTS. The measurement point is A, as shown in
Unit Figure 1.
Times

C901240013
Definition
Description Maximum value of received DL signal strength
This counter counts Maximum value of received DL signal
Usage strength in the measurement report of a timeslot in a cell.
This counter is used to find out the Maximum value of received
DL signal strength in a timeslot of a cell. It is one of the
Measurement parameters that evaluate timeslot radio environment.
Point After BSC receives the measurement report from BTS, if DL
reception strength in the report is bigger than the value in the
counter, the DL reception strength in the counter is replaced.
Unit The measurement point is A, as shown in Figure 1.
dBm

C901240014
Definition
Description Minimum value of received DL signal strength
This counter counts Minimum value of received DL signal
Usage strength in the measurement report of a timeslot in a cell.
This counter is used to find out the Minimum value of received
DL signal strength in a timeslot in a cell. It is one of the
Measurement parameters that evaluate timeslot radio environment.
Point After BSC receives the measurement report from BTS, if DL
reception strength in the report is less than the value in the
counter, the DL reception strength in the counter is replaced.
Unit The measurement point is A, as shown in Figure 1.
dBm

Confidential and Proprietary Information of ZTE CORPORATION 7


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Definition
C901240015
Description
Total value of received DL signal strength

Usage This counter counts the total value of received DL signal


strength in a timeslot in a cell in the measurement report.
This counter is used to find out the total value of received DL
Measurement signal strength in a timeslot in a cell. It is one of the parameters
Point that evaluate timeslot radio environment.
After BSC receives the measurement report from BTS, the
Unit counter accumulates DL reception strength value for relevant
timeslot. The measurement point is A, as shown in Figure 1.
dBm

Definition
C901240016
Description
Number of received DL signal strength samples

Usage This counter counts the number of times of sampling received


DL signal strength in a timeslot in a cell.
This counter shows the frequency of sampling received DL signal
Measurement strength in a timeslot in a cell. It is one of the parameters that
Point evaluate timeslot radio environment.
The counter increments after BSC receives the measurement
Unit report from BTS. The measurement point is A, as shown in
Figure 1.
Times

Definition
C901240017
Description
Total value of power scans of MS transmitting power

Usage This counter counts the total value of MS transmitting power in a


timeslot in a cell in the measurement report.
This counter is used to find out the total value of MS
Measurement transmitting power in a timeslot in a cell. It is one of the
Point parameters that evaluate timeslot radio environment.
After BSC receives the measurement report from BTS, the
Unit counter accumulates MS power value for relevant timeslot. The
measurement point is A, as shown in Figure 1.
dBm

8 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Timeslot Measurement

Definition
C901240018
Description
Number of power scans of MS transmitting power

Usage This counter counts the number of times of sampling MS


transmitting power in a timeslot in a cell.
This counter shows the frequency of sampling MS transmitting
Measurement power in a timeslot in a cell. It is one of the parameters that
Point evaluate timeslot radio environment.
The counter increments after BSC receives the measurement
Unit report from BTS. The measurement point is A, as shown in
Figure 1.
Times

Definition
C901240019
Description
Total value of power scans of BTS power

Usage This counter counts the total value of BTS power in a timeslot in
a cell in the measurement report.
This counter is used to find out the total value of BTS power in a
Measurement timeslot in a cell. It is one of the parameters that evaluate
Point timeslot radio environment.
After BSC receives the measurement report from BTS, the
Unit counter accumulates BTS power value for relevant timeslot. The
measurement point is A, as shown in Figure 1.
dBm

Definition
C901240020
Description
Number of power scans of BTS power

Usage This counter counts the number of times of sampling BTS power
in a timeslot in a cell.
This counter shows the frequency of power scans of BTS power
Measurement in a timeslot in a cell. It is one of the parameters that evaluate
Point timeslot radio environment.
The counter increments after BSC receives the measurement
Unit report from BTS. The measurement point is A, as shown in
Figure 1.
Times

Confidential and Proprietary Information of ZTE CORPORATION 9


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901240021
Definition Number of immediate assignment failure
Description This counter counts the number of times of immediate
assignment failure in a timeslot in a cell.
Usage This counter shows the frequency of immediate assignment
failure in a timeslot in a cell. It is one of the parameters that
evaluate timeslot radio environment.
Measurement After BSC sent immediate assignment to MS, if access Timer
Point overtimes, the counter increments in relevant timeslot. The
measurement point is A2, as shown in Figure 2.
In the waiting state, case release caused by any reason, leads
immediate assignment failure, then the counter increments in
relevant timeslot. The measurement point is A1, as shown in
Figure 2.

FIGURE 2 – IMMEDIATE ASSIGNMENT FAILURE MEASUREMENT POINT

Unit Times

C901240022
Definition Number of assignment failure
Description This counter counts the number of times of assignment failure in
a timeslot in a cell.
Usage This counter shows the frequency of assignment failure in a
timeslot in a cell. It is one of the parameters that evaluate
timeslot radio environment.
Measurement After BSC sent assignment to MS, if access Timer overtimes, the
Point counter increments in relevant timeslot. The measurement point
is A2, as shown in Figure 3.

10 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Timeslot Measurement

In the waiting state, case release caused by any reason, leads


assignment failure, then the counter increments in relevant
timeslot. The measurement point is A1, as shown in Figure 3.

FIGURE 3 – ASSIGNMENT FAILURE ME ASUREMENT POINT

Unit

Times
Definition
Description
C901240023
Usage
Number of handovers failure
This counter counts the number of times of handover failure in a
Measurement
timeslot in a cell.
Point
This counter shows the frequency of handover failure in a
timeslot in a cell. It is one of the parameters that evaluate
timeslot radio environment.
(1) After BSC sent handover to MS, if access Timer overtimes,
the counter increments in relevant timeslot. The measurement
point is A2, as shown in Figure 4.
(2) In the waiting state, case release caused by any reason,
leads handover failure, then the counter increments in relevant
timeslot. The measurement point is A1, as shown in Figure 4.

Confidential and Proprietary Information of ZTE CORPORATION 11


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

FIGURE 4 –HANDOVERS FAILURE MEASUREMENT POINT

Unit Times

C901240024
Definition Maximum interference value
Description This counter counts the Maximum interference band value in a
timeslot in a cell.
Usage This counter shows the Maximum interference band value in a
timeslot in a cell. It is one of the parameters that evaluate
timeslot radio environment.
Measurement When BSC received resource indication from BTS updating
Point interference band, if interference band reported is bigger than
the value in the counter, the value in the counter is replaced.
The measurement point is A, as shown in Figure 5.

FIGURE 5 – RESOURCE INDICATION MEASUREMENT POINT

Unit NA

C901240025
Definition Minimum interference value

12 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Timeslot Measurement

Description This counter counts the Minimum interference band value in a


timeslot in a cell.
Usage This counter shows the Minimum interference band value in a
timeslot in a cell. It is one of the parameters that evaluate
timeslot radio environment.
Measurement When BSC received resource indication from BTS updating
Point interference band, if interference band reported is less than the
value in the counter, the value in the counter is replaced. The
measurement point is A, as shown in Figure 5.
Unit NA

C901240026
Definition Total value of interference
Description This counter counts the total value of interference band in a
timeslot in a cell.
Usage This counter is used to find out the total value of interference
band in a timeslot in a cell. It is one of the parameters that
evaluate timeslot radio environment.
Measurement When BSC received resource indication from BTS updating
Point interference band, the counter accumulates interference value
for relevant timeslot. The measurement point is A, as shown in
Figure 5.
Unit NA

C901240027
Definition Number of regular scanning and sampling of interference value
Description This counter counts the number of times of interference band
value report in a timeslot in a cell.
Usage This counter is used to find out the frequency of interference
band value sampling in a timeslot in a cell. It is one of the
parameters that evaluate timeslot radio environment.
Measurement The counter increments in relevant timeslot after BSC receives
Point resource indication from BTS updating interference band. The
measurement point is A, as shown in Figure 5.
Unit Times

C901240028
Definition Number of call drop

Confidential and Proprietary Information of ZTE CORPORATION 13


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Description

This counter counts the number of call drop caused by radio link
Usage failure in a timeslot in a cell.
This counter is used to find out the frequency of call drop caused
by radio link failure in a timeslot in a cell. It is one of the
Measurement parameters that evaluate timeslot radio environment.
Point
The counter increments in relevant timeslot after BSC receives
radio link failure from BTS. The measurement point is A, as
Unit shown in Figure 5.
Times

C901240029
Definition
Description Maximum value of path balance
This counter counts the Maximum value of path balance in a
timeslot in a cell. Path balance is the path loss margin of UL and
Usage DL path.
This counter shows the Maximum value of path balance in a
timeslot in a cell. It is one of the parameters that evaluate
Measurement timeslot radio environment.
Point
When BSC receives measurement report from BTS, calculate the
current path loss. Then path balance is calculated according UL
and DL path loss. If the path balance calculated is more than the
value in the counter, then the value in the counter is replaced.
Unit The measurement point is A, as shown in Figure 1.
dBm

C901240030
Definition
Description Minimum value of path balance
This counter counts the Minimum value of path balance in a
timeslot in a cell. Path balance is the path loss margin of UL and
Usage DL path.
This counter shows the Minimum value of path balance in a
timeslot in a cell. It is one of the parameters that evaluate
Measurement timeslot radio environment.
Point
When BSC receives measurement report from BTS, calculate the
current path loss. Then path balance is calculated according UL
and DL path loss. If the path balance calculated is less than the
value in the counter, then the value in the counter is replaced.
Unit The measurement point is A, as shown in Figure 1.
dBm

14 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Timeslot Measurement

C901240031
Definition Total value of path balance
Description This counter counts the total value of path balance in a timeslot
in a cell.
Usage This counter is used to find out the total value of path balance in
a timeslot in a cell. It is one of the parameters that evaluate
timeslot radio environment.
Measurement When BSC receives measurement report from BTS, calculate the
Point current path loss. Then path balance is calculated according UL
and DL path loss. The counter accumulates the path balance for
relevant timeslot. The measurement point is A, as shown in
Figure 1.
Unit dBm

C901240032
Definition Number of path balance sampling
Description This counter counts the number of path balance sampling in a
timeslot in a cell.
Usage This counter is used to find out the frequency of path balance
sampling in a timeslot in a cell. It is one of the parameters that
evaluate timeslot radio environment.
Measurement The counter increments in relevant timeslot when BSC receives
Point measurement point from BTS and calculates path balance. The
measurement point is A, as shown in Figure 1.
Unit Times

C901240033
Definition Total value of UL loss
Description This counter counts the total value of UL loss in a timeslot in a
cell.
Usage This counter is used to find out the total value of UL loss in a
timeslot in a cell. It is one of the parameters that evaluate
timeslot radio environment.
Measurement When BSC receives measurement report from BTS, calculate the
Point current path loss. Then path balance is calculated according UL
and DL path loss. The counter accumulates the path balance for
relevant timeslot. The measurement point is A, as shown in
Figure 1.
Unit dBm

Confidential and Proprietary Information of ZTE CORPORATION 15


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901240034
Definition Number of regular scanning and sampling of UL loss
Description This counter counts the number of UL loss in a timeslot in a cell.
Usage This counter is used to find out the frequency of sampling in UL
path in a timeslot in a cell. It is one of the parameters that
evaluate radio environment.
Measurement When BSC receives measurement report from BTS, calculate the
Point current UL path loss. The counter increments if UL path loss is
valid. The measurement point is A, as shown in Figure 1.
Unit Times

C901240035
Definition Total value of DL loss
Description This counter counts the maximum of DL loss in a timeslot in a
cell.
Usage This counter is used to find out the maximum of UL path loss in
a timeslot in a cell. It is one of the parameters that evaluate
radio environment.
Measurement When BSC receives measurement report from BTS, calculate the
Point current DL path loss. The counter increments if DL path loss is
valid. The measurement point is A, as shown in Figure 1.
Unit dB

C901240036
Definition Number of regular scanning and sampling of DL loss
Description This counter counts the number of DL loss in a timeslot in a cell.
Usage This counter is used to find out the frequency of sampling in DL
path in a timeslot in a cell. It is one of the parameters that
evaluate radio environment.
Measurement When BSC receives measurement report from BTS, calculate the
Point current UL path loss. The counter increments if DL path loss is
valide. The measurement point is A, as shown in Figure 1.
Unit Times

C901240037
Definition Number of drops due to the bad quality of UL receive

16 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Timeslot Measurement

Description

Usage

Measurement This counter counts the number of call drops on some timeslot in
Point the cell due to radio link failure. After MS obtains SDCCH or TCH,
call drop occurs. If the problem is caused by bad uplink receiving
quality, the counter increments.
This counter is used to find out the frequency of call drop on
some timeslot due to radio link failure which is caused by bad
uplink receiving quality. It is one of the radio parameters that
evaluate the timeslot.
„ The counter counts when BSC receives the CONNectiOn
FAILure INDicatiOn message at Abis interface on SDCCH. The
measurement point is A, as shown in Figure 6.
„ The counter counts when BSC receives the CONNectiOn
FAILure INDicatiOn message at Abis interface on TCH. The
measurement point is A, as shown in Figure 7.

FIGURE 6 – CALL DROP DUE TO RADIO LINK FAILURE DURING IMMEDIATE


ASSIGNMENT PROCESS

Confidential and Proprietary Information of ZTE CORPORATION 17


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

FIGURE 7 – CALL DROP DUE TO RADIO LINK FAILURE DURING ASSIGNMENT


PROCESS

MS BTS BSC MSC

CH REQ
CH REQ
CH ACT
CH ACT ACK
IMM ASS CMD
IMM ASS
SABM
ETS IND
UA CR:CM SERV REQ
CC
DT1:CIPH MODE CMD
ENCRY CND
CIPH MODE CMD
CIPH MODE COM
DI:CIPH MODE COM
DT1:CIPH MODE COM

DTAP

DT1:ASS REQ
PHY CON REQ
PHY CON CONF
CH ACT
CH ACT ACK
DR:ASS CMD
ASS CMD
SABM
EST IND
UA
ASS COM
DI:ASS COM
DT1:ASS COM

DTAP

CONN FAIL IND

Unit
Times

C901240038
Definition
Number of drops due to the bad quality of DL receive
Description
This counter counts the number of call drops on some timeslot in
the cell due to radio link failure. After MS obtains SDCCH or TCH,
call drop occurs. If the problem is caused by bad downlink
receiving quality, the counter increments.
Usage
This counter is used to find out the frequency of call drop on
some timeslot due to radio link failure which is caused by bad
downlink receiving quality. It is one of the radio parameters that
evaluate the timeslot.
Measurement
Point „ The counter counts when BSC receives the CONNectiOn
FAILure INDicatiOn message at Abis interface on SDCCH. The
measurement point is A, as shown in Figure 6.

18 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Timeslot Measurement

„ The counter counts when BSC receives the CONNectiOn


FAILure INDicatiOn message at Abis interface on TCH. The
Unit measurement point is A, as shown in Figure 7.
Times

C901240039
Definition
Description Number of drops due to the low electric level of UL
This counter counts the number of call drops on some timeslot in
the cell due to radio link failure. After MS obtains SDCCH or TCH,
call drop occurs. If the problem is caused by low uplink receiving
Usage level, the counter increments.
This counter is used to find out the frequency of call drop on
some timeslot due to radio link failure which is caused by low
uplink receiving level. It is one of the radio parameters that
Measurement evaluate the timeslot.
Point „ The counter counts when BSC receives the CONNectiOn
FAILure INDicatiOn message at Abis interface on SDCCH. The
measurement point is A, as shown in Figure 6.
„ The counter counts when BSC receives the CONNectiOn
FAILure INDicatiOn message at Abis interface on TCH. The
Unit measurement point is A, as shown in Figure 7.
Times

C901240040
Definition
Description Number of drops due to the low electric level of DL
This counter counts the number of call drops on some timeslot in
the cell due to radio link failure. After MS obtains SDCCH or TCH,
call drop occurs. If the problem is caused by low downlink
Usage receiving level, the counter increments.
This counter is used to find out the frequency of call drop on
some timeslot due to radio link failure which is caused by low
downlink receiving level. It is one of the radio parameters that
Measurement evaluate the timeslot.
Point „ The counter counts when BSC receives the CONNectiOn
FAILure INDicatiOn message at Abis interface on SDCCH. The
measurement point is A, as shown in Figure 6.
„ The counter counts when BSC receives the CONNectiOn
FAILure INDicatiOn message at Abis interface on TCH. The
Unit measurement point is A, as shown in Figure 7.
Times

Confidential and Proprietary Information of ZTE CORPORATION 19


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901240041
Definition Number of drops due to the TA too far
Description This counter counts the number of call drops on some timeslot in
the cell due to radio link failure. After MS obtains SDCCH or TCH,
call drop occurs. If the problem is caused by TA being too far,
the counter increments.
Usage This counter is used to find out the frequency of call drop on
some timeslot due to radio link failure which is caused by TA
being too far. It is one of the radio parameters that evaluate the
timeslot.
Measurement „ The counter counts when BSC receives the CONNectiOn
Point FAILure INDicatiOn message at Abis interface on SDCCH. The
measurement point is A, as shown in Figure 6.
„ The counter counts when BSC receives the CONNectiOn
FAILure INDicatiOn message at Abis interface on TCH. The
measurement point is A, as shown in Figure 7.
Unit Times

C901240042
Definition Number of drops due to the other radio reasons
Description This counter counts the number of call drops on some timeslot in
the cell due to radio link failure. After MS obtains SDCCH or TCH,
call drop occurs. If the problem is not due to the above five
causes (i.e. bad uplink receiving quality, bad downlink receiving
quality, low uplink receiving level, low downlink receiving level,
and TA being too far), the counter increments.
Usage This counter is used to find out the frequency of call drop on
some timeslot due to radio link failure which is caused by other
radio problems. It is one of the radio parameters that evaluate
the timeslot.
Measurement „ The counter counts when BSC receives the CONNectiOn
Point FAILure INDicatiOn message at Abis interface on SDCCH. The
measurement point is A, as shown in Figure 6.
„ The counter counts when BSC receives the CONNectiOn
FAILure INDicatiOn message at Abis interface on TCH. The
measurement point is A, as shown in Figure 7.
Unit Times

C901240043
Definition The valid time of the used voice channel

20 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Timeslot Measurement

Description
This counter counts the valid occupation time of a timeslot's
voice channel in the cell.
Usage
This counter is used to find out the sum of valid occupation time
of a timeslot's voice channel in the cell. It is one of the radio
parameters that evaluate the timeslot.
Measurement
Point When BSC receives the measurement report from BTS, the
counter is accumulated with a time value. Different
measurement report type corresponds to different value, for
common measurement report, the time value is 480 ms. The
measurement point is A, as shown in Figure 8.

FIGURE 8 – BSC RECEIVES MEASUREMENT REPORT FROM BTS

Unit
ms

C901240044
Definition
Number of activated voice channel
Description
This counter counts the number of a timeslot's voice channel
being activated in the cell.
Usage
This counter is used to find out the frequency of a timeslot's
voice channel being activated in the cell. It is one of the radio
parameters that evaluate the timeslot.
Measurement
Point When BSC receives the CHANNEL ACTIVATE ACK message, the
counter increments. The measurement point is A, as shown in
Figure 9.

FIGURE 9 – MEASUREMENT POINT WHEN CHANNEL IS ACTIVATED

BTS BSC

CHANNEL ACTIVATE

CHANNEL ACTIVATE ACK

Unit
Times

Confidential and Proprietary Information of ZTE CORPORATION 21


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

This page is intentionally blank.

22 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2

SDCCH Measurement

This chapter contains detailed information about counters


related to SDCCH measurement.

Overview
SDCCH counters describe allocation, occupation, assignment,
use of resources related to SDCCH, which as SDCCH
configuration and parameters adjustment basis. Allocation of
SDCCH is mainly in the process of immediate assignment and
handover. Handover includes internal and external handover.
The statistic unit in this measurement is cell.
The Measurement point Of SDCCH counters in the process of
immediate assignment is shown in Figure 10.

FIGURE 10 – THE PROCESS OF IMMEDIATE ASSIGNMENT

MS BTS BSC
CHL_REQ
CHL_RQD

A1

CHL_ACT

CHL_ACT_ACK

IMM _ASS _CMD

A2
IMM_ASS
SABM
EST_IND

A3

Confidential and Proprietary Information of ZTE CORPORATION 23


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

The Measurement point Of SDCCH counters in the process of


internal handover (like intra-cell handover) is shown in Figure 11.

FIGURE 11 –THE PROCESS OF INTERNAL HANDOVER (LIKE INTRA-CELL


HANDOVER)

The Measurement point Of SDCCH counters in the process of


external handover is shown in Figure 12.

FIGURE 12 –THE PROCESS OF EXTERNAL HANDOVER

24 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - SDCCH Measurement

SDCCH measurement Counter


Index
Table 6 lists counters related to SDCCH measurement.

TABLE 6 - SDCCH MEASUREMENT COUNTER

Counter ID What It Counts


C901250005 Number of SDCCH seizure success for Handover
Number of SDCCH allocation attempts for
C901250007
Assignment
C901250010 Number of SDCCH allocation attempts for handover
C901250011 Number of SDCCH allocation success for handover
C901250012 Number of SDCCH allocation failure for handover
C901250016 Number of SDCCH handover failure
C901250017 Number of SDCCH handover success
Number of SDCCH handover failure with
C901250018
Reconnection
Number of SDCCH handover failure without
C901250019
Reconnection

C901250005
Definition Number of SDCCH seizure success for Handover
Description SDCCH allocation attempt is triggered by the channel request
message RADIO_APPLY from other channel instances. BSC
attempts to allocate SDCCH after receiving the message. If
SDCCH allocation and seizure succeed, the counter increments.
If application response shows no SDCCH available but queuing
or forced release is possible, enter the state of waiting for
resource. If SDCCH is available after waiting, then the counter
increments. If application response shows transceiver is faulty,
the three counters do not change.
Usage This counter records the number of SDCCH seizure success for
handover.
Measurement When BSC requesting for SDCCH (due to handover) is completed
Point and SDCCH seizure succeeds, or BSC gets valid response of
waiting resource. The measurement point is B1 as shown in
Figure 11, and C1 as shown in Figure 12.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 25


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901250007
Definition Number of SDCCH allocations attempts for assignment
Description This counter records the number of SDCCH allocations attempts
for assignment, including successful allocations (C900060008)
and unsuccessful allocations (C900060009).
Usage After BSC responds the channel request message to allocate and
occupy SDCCH channel successfully, BSC sends the CHL_ACT
message to BTS to activate this SDCCH channel. If the activation
succeeds (that is, when BSC receives the CHL_ACT_ACK
message from BTS), this counter and C900060008 increment
simultaneously. Otherwise, if the channel could not be activated
due to receiving channel activation failure message, incorrect
channel activation response message, T9103 timeout, channel
instance being released or channel being released forcibly, this
counter and C900060009 increment simultaneously.
Measurement BSC activates SDCCH due to assignment
Point (C900060008+C900060009). The measurement point is A2 as
shown in Figure 10.
Unit Times

C901250010
Definition Number of SDCCH allocation attempts for handover
Description After BSC responds the channel request message to allocate and
occupy SDCCH channel successfully, BSC sends the CHL_ACT
message to BTS to activate this SDCCH channel. If the activation
succeeds (that is, when BSC receives the CHL_ACT_ACK
message from BTS), this counter and C901250011 increment
simultaneously. Otherwise, if the channel could not be activated
due to receiving channel activation failure message, incorrect
channel activation response message, T9103 timeout, channel
instance being released or channel being released forcibly, this
counter and C901250012 increment simultaneously.
Usage This counter records the number of SDCCH allocations attempts
for handover, including successful allocations (C901250011) and
unsuccessful allocations (C901250012).
Measurement BSC activates SDCCH due to handover
Point (C901250011+C901250012). The measurement point is B2 as
shown in Figure 11 and C2 as shown in Figure 12.
Unit Times

26 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - SDCCH Measurement

C901250011
Definition Number of SDCCH allocation success for handover
Description After BSC responds the channel request message to allocate and
occupy SDCCH channel successfully, BSC sends the CHL_ACT
message to BTS to activate this SDCCH channel. If the activation
succeeds (that is, when BSC receives the CHL_ACT_ACK
message from BTS), it means SDCCH allocation succeeds
completely and this counter increments.
Usage This counter records the number of SDCCH allocations success
for handover.
Measurement When BSC receives the CHL_ACT_ACK message from BTS due to
Point handover, the measurement point is B2 as shown in Figure 11
and C2 as shown in Figure 12.
Unit Times

C901250012
Definition Number of SDCCH allocation failure for handover
Description After BSC responds the channel request message to allocate and
occupy SDCCH channel successfully, BSC sends the CHL_ACT
message to BTS to activate this SDCCH channel. If the channel
could not be activated due to receiving channel activation failure
message, incorrect channel activation response message, T9103
timeout, channel instance being released or channel being
released forcibly, this counter increments.
Usage This counter records the number of SDCCH allocations failure for
handover.
Measurement BSC activates SDCCH for handover, but encounters the following
Point situation: receives channel activation failed message, channel
activation response message is incorrect, T9103 is time-out,
channel instance is released, or channel is released forcibly. The
measurement point is B2 as shown in Figure 11 and C2 as
shown in Figure 12.
Unit Times

C901250016
Definition Number of SDCCH handover attempts
Description In the process of handover, when MS accesses successfully in
the new channel, BSC will receive assignment complete message
ASS_COM (intra-cell handover) or HO_COM (inter-cell handover).

Confidential and Proprietary Information of ZTE CORPORATION 27


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

If BSC receives successfully above message within assigned time,


which means handover succeeds. This counter and C901250017
increment simultaneously. If BSC receives HO_FAILURE
message, this counter and C901250018 increment
simultaneously. Otherwise, handover fails and same time BSC
has not received any failure message, this counter and
C901250019 increment simultaneously.
Usage This counter records the attempts number of MS accesses
SDCCH newly allocated in the process of handover, including
successful handover times (C901250017), failed handover times
(C901250018) with HO_FAILURE message and failed handover
times (C901250019) without HO_FAILURE message.
Measurement When BSC receives ASS_COM message (intra-cell handover),
Point HO_COM message (inter-cell handover), HO_FAILURE message
or HO_FAILURE abnormally, time-out message, channel instance
is released, or channel is released forcibly. The measurement
point is B3 as shown in Figure 11 and C3 as shown in Figure 12.
Unit Times

C901250017
Definition Number of SDCCH handover success
Description In the process of handover, when MS accesses successfully in
the new channel, BSC will receive assignment complete message
ASS_COM (intra-cell handover) or HO_COM (inter-cell handover).
If BSC receives successfully above message within assigned time,
which means handover succeeds, this counter increments.
Usage This counter records the number of MS accesses successfully
SDCCH newly allocated in the process of handover.
Measurement BSC receives ASS_COM message (intra-cell handover) or
Point HO_COM message (inter-cell handover). The measurement point
is B3 as shown in Figure 11 and C3 as shown in Figure 12.
Unit Times

C901250018
Definition Number of SDCCH handover failure with Reconnection
Description In the process of handover, when BSC receives ASSIGN_FAIL
message or HO_FAIL message, this counter increments.
Usage This counter records the number of MS accesses unsuccessfully
SDCCH newly allocated in the process of handover and BSC
receives handover failure message.
Measurement BSC receives HO_FAILURE message.
Point

28 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - SDCCH Measurement

Unit Times

C901250019
Definition Number of SDCCH handover failure without Reconnection
Description If handover fails and at same time BSC has not received any
HO_FAILURE message, this counter increments.
Usage This counter records the number of MS accesses unsuccessfully
SDCCH newly allocated in the process of handover and BSC has
not received any HO_FAILURE message.
Measurement When BSC has not received any HO_FAILURE message, time-out
Point message, channel instance is released, or channel is released
forcibly.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 29


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

This page is intentionally blank.

30 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3

TCH/F Measurement

Task of TCH/F measurement is to mainly measure TCH/F related


resource allocation, seizure, assignment, and usage. This
chapter introduces the meaning, usage and measurement point
to measure different performance counters by TCH/F.

Overview
In GSM BSC signaling system, allocation and usage of TCH/F
channel mainly exist in assignment and handover flow, where
assignment flow includes immediate assignment and common
assignment; handover flow includes internal and external
handover.
For the measurement positions of TCH/F counter in immediate
assignment flow, see Figure 13.

FIGURE 13 - IMMEDIATE ASSIGNMENT FLOW

MS BTS BSC
CHL_REQ
CHL_RQD
A1
CHL_ACT

CHL_ACT_ACK
A2
IMM_ASS_CMD
IMM_ASS

SABM EST_IND

A3

During internal and external TC, for the measurement positions


of TCH/F counter in common assignment flow, see Figure 14 and
Figure 15.

Confidential and Proprietary Information of ZTE CORPORATION 31


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

FIGURE 14 - COMMON ASSIGNMENT FLOW (INTERNAL TC)

MS BTS BSC MSC


ASS_REQ
B1
Abis,TCU connect
CHL_ACT B2

CHL_ACT_ACK

ASS_CMD B3
ASS_CMD
SABM

UA EST_IND
ASS_COM B4
ASS_COM

B5 ASS_COM

FIGURE 15 - COMMON ASSIGNMENT FLOW (EXTERNAL TC)

During internal and external TC, for the measurement positions


of TCH/F counter in internal handover flow (like intra-cell
handover), see Figure 16 and Figure 17.

32 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

FIGURE 16 - INTERNAL H ANDOVER (LIKE INTRA-CELL HANDOVER) FLOW


(INTERNAL TC)

MS BTS BSC MSC


MEAS_REP
MEAS_RES
C1
Abis,TCU connect
CHL_ACT C2

CHL_ACT_ACK

ASS_CMD C3
ASS_CMD
SABM

UA EST_IND
ASS_COM
ASS_COM

C4 HO_PREFORM

FIGURE 17 - INTERNAL H ANDOVER (DURING INTRA-CELL HANDOVER, AND


CHANNEL TYPES ARE CH ANGED) FLOW (EXTERNAL TC)

During internal and external TC, for the measurement positions


of TCH/F counter in external handover flow, see Figure 18 and
Figure 19.

Confidential and Proprietary Information of ZTE CORPORATION 33


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

FIGURE 18 - EXTERNAL H ANDOVER FLOW (INTERNAL TC)

FIGURE 19 - EXTERNAL H ANDOVER FLOW (EXTERNAL TC)

TCH/F Measurement Counter Index


Table 7 lists counters related to TCH/F measurement.

TABLE 7 - TCH/F MEASUREMENT COUNTER

Counter ID What It Counts


Number of signaling TCH/F seizure success for
C901260002
assignment
Number of signaling TCH/F seizure success for
C901260005
handover

34 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

Counter ID What It Counts


Number of signaling TCH/F allocation attempts for
C901260007
assignment
Number of signaling TCH/F allocation attempts for
C901260010
handover
Number of signaling TCH/F allocation success for
C901260011
handover
Number of signaling TCH/F assignment attempts
C901260013
for assignment
C901260016 Number of signaling TCH/F handover attempt
C901260017 Number of signaling TCH/F handover success
Number of signaling TCH/F handover failure with
C901260018
reconnection
Number of signaling TCH/F handover failure
C901260019
without reconnection
Number of voice TCH/F seizure success for
C901260021
assignment
Number of voice TCH/F seizure success for
C901260024
handover
Number of TCH/F allocation attempts for
C901260026
assignment (speech version 1)
Number of TCH/F allocation attempts by BSC for
C901260032
handover (speech version 1)
Number of TCH/F allocation success by BSC for
C901260033
handover (speech version 1)
Number of TCH/F allocation attempts for
C901260038
assignment (speech version 2)
Number of TCH/F allocation attempts by BSC for
C901260044
handover (speech version 2)
Number of TCH/F allocation success by BSC for
C901260045
handover (speech version 2)
Number of TCH/F allocation attempts by BSC for
C901260050
assignment (speech version 3)
Number of TCH/F allocation attempts by BSC for
C901260056
handover (speech version 3)
Number of TCH/F allocation success by BSC for
C901260057
handover (speech version 3)
Number of voice TCH/F assignment attempts by
C901260062
BSC
C901260065 Number of voice TCH/F handover attempts
C901260067 Number of Voice TCH/F handover failure
C901260068 Number of Voice TCH/F handover failure messages
do not received by BSC
C901260070 Number of data TCH/F seizure success for
assignment

Confidential and Proprietary Information of ZTE CORPORATION 35


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Counter ID What It Counts


C901260073 Number of data TCH/F seizure success for
handover
C901260075 Number of data TCH/F allocation attempts for
assignment
C901260081 Number of data TCH/F allocation attempts by BSC
for handover
C901260082 Number of data TCH/F allocation success for
handover
C901260087 Number of data TCH/F assignment attempts
C901260090 Number of data TCH/F handover attempts
C901260092 Number of data TCH/F handover failure
C901260093 Number of data TCH/F handover failure messages
do not received by BSC
Number of data TCH/F allocation failure for
C901260094 assignment due to TIPB connection failure (Speech
version 1)
Number of data TCH/F allocation failure for
C901260095 assignment due to Resource request to iTC failure
(Speech version 1)
Number of data TCH/F allocation failure for
C901260096 handover due to TIPB connection failure (Speech
version 1)
Number of data TCH/F allocation failure for
C901260097 handover due to Resource request to iTC failure
(Speech version 1)
Number of data TCH/F allocation failure for
C901260098 assignment due to TIPB connection failure (Speech
version 2)
Number of data TCH/F allocation failure for
C901260099 assignment due to Resource request to iTC failure
(Speech version 2)
Number of data TCH/F allocation failure for
C901260100 handover due to TIPB connection failure (Speech
version 2)
Number of data TCH/F allocation failure for
C901260101 handover due to Resource request to iTC failure
(Speech version 2)
Number of data TCH/F allocation failure for
C901260102 assignment due to TIPB connection failure (Speech
version 3)
Number of data TCH/F allocation failure for
C901260103 assignment due to Resource request to iTC failure
(Speech version 3)
Number of data TCH/F allocation failure for
C901260104 handover due to TIPB connection failure (Speech
version 3)

36 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

Counter ID What It Counts


Number of data TCH/F allocation failure for
C901260105 handover due to Resource request to iTC failure
(Speech version 3)
Number of TCH/F allocation failure due to request
C901260106 AIPB resource failure for assignment (speech
version 1)
Number of TCH/F allocation failure due to request
C901260107
UDP port failure for assignment (speech version 1)
Number of TCH/F allocation failure due to AIPB
C901260108 connection failure for assignment (speech version
1)
Number of TCH/F allocation failure due to request
C901260109 AIPB resource failure for handover (speech version
1)
Number of TCH/F allocation failure due to request
C901260110
UDP port failure for handover (speech version 1)
Number of TCH/F allocation failure due to AIPB
C901260111
connection failure for handover (speech version 1)
Number of TCH/F allocation failure due to request
C901260112 AIPB resource failure for assignment (speech
version 2)
Number of TCH/F allocation failure due to request
C901260113
UDP port failure for assignment (speech version 2)
Number of TCH/F allocation failure due to AIPB
C901260114 connection failure for assignment (speech version
2)
Number of TCH/F allocation failure due to request
C901260115 AIPB resource failure for handover (speech version
2)
Number of TCH/F allocation failure due to request
C901260116
UDP port failure for handover (speech version 2)
Number of TCH/F allocation failure due to AIPB
C901260117
connection failure for handover (speech version 2)
Number of TCH/F allocation failure due to request
C901260118 AIPB resource failure for assignment (speech
version 3)
Number of TCH/F allocation failure due to request
C901260119
UDP port failure for assignment (speech version 3)
Number of TCH/F allocation failure due to AIPB
C901260120 connection failure for assignment (speech version
3)
Number of TCH/F allocation failure due to request
C901260121 AIPB resource failure for handover (speech version
3)
Number of TCH/F allocation failure due to request
C901260122
UDP port failure for handover (speech version 3)
C901260123 Number of TCH/F allocation failure due to AIPB

Confidential and Proprietary Information of ZTE CORPORATION 37


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Counter ID What It Counts


connection failure for handover (speech version 3)
Number of TCH/F allocation failure due to request
C901260124
AIPB resource failure for assignment (data)
Number of TCH/F allocation failure due to request
C901260125
UDP port failure for assignment (data)
Number of TCH/F allocation failure due to AIPB
C901260126
connection failure for assignment (data)
Number of TCH/F allocation failure due to request
C901260127
AIPB resource failure for handover (data)
Number of TCH/F allocation failure due to request
C901260128
UDP port failure for handover (data)
Number of TCH/F allocation failure due to AIPB
C901260129
connection failure for handover (data)
Number of assign TCH/F release by forced
C901260130
handover to forced handover source
Number of assign TCH/F release by forced
C901260131
handover to queuing user
Number of restore TCH/F release by forced
C901260132
handover to DBS
Number of assign TCH/F release by forced release
C901260133
to forced release source
Number of assign TCH/F release by forced release
C901260134
to queuing user
Number of restore TCH/F release by forced release
C901260135
to DBS

C901260002
Definition Number of signaling TCH/F seizure success for assignment
Description This counter counts the number of signaling TCH/F seizure
success during assignment of signaling channel.
After BSC receives channel request message, it will try to
allocate channel for this request. If allocation and seizure
succeed, this counter accumulates.
Measurement BSC successfully applies for channel (due to assignment, used
Point for signaling channel) and does successful assignment. The
measurement point is A1, as shown in Figure 13.
Unit Times

C901260005
Definition Number of signaling TCH/F seizure success for handover

38 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

Description This counter counts the number of signaling TCH/F seizure


success during handover of signaling channel.
After BSC receives channel request message, it will try to
allocate channel for this request. If allocation and seizure
succeed, this counter accumulates. If no channel is returned
after application but queuing or force release can be conducted,
it will enter into the state to wait for resource, this counter
accumulates when corresponding resource occurs.
Measurement BSC successfully applies for channel (due to handover, used for
Point signaling channel) and does successful seizure, or BSC receives
internal waiting resource effective message. The measurement
points are C1 and D1, as shown in Figure 16, Figure 17, Figure
18, and Figure 19.
Unit Times

C901260007
Definition Number of signaling TCH/F allocation attempts for assignment
Description This counter counts the number of signaling TCH/F allocation
attempts when assigning signaling channel, including the
number of allocation success (C900060014) and failure
(C900060014).
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC sends channel activation
message CHL_ACT to activate this TCH/F. if activation success,
CHL_ACT_ACK message sent by BTS will be received, indicating
TCH/F allocation success, this counter and C900060014
accumulate simultaneously; reversely, if channel activation
failure due to receive channel activation failure message,
incorrect channel activation response message, timer T9103
timeout, channel instance released, channel force-released, this
counter and C900060015 accumulate simultaneously.
Measurement After BSC activates TCH/F (due to assignment, used for
Point signaling channel), this counter accumulates when
CHL_ACT_ACK message sent by BTS is received correctly,
channel activation failure message is received, channel
activation response message is not correct, timer T9103 times
out, channel instance is released, or channel is forcibly released.
(C900060014+C900060015) The measurement point is A2, as
shown in Figure 13.
Unit Times

C901260010
Definition Number of signaling TCH/F allocation attempts for handover
Description

Confidential and Proprietary Information of ZTE CORPORATION 39


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

This counter counts the number of signaling TCH/F allocation


attempts during handover of signaling channel, including the
number of allocation success (C901260011) and failure
(C900060016).
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC sends channel activation
message CHL_ACT to BTS to activate this TCH/F. if activation
success, CHL_ACT_ACK message sent by BTS will be received,
indicating TCH/F allocation success, this counter and
C901260011 accumulate simultaneously; reversely, if channel
activation failure due to receive channel activation failure
message, incorrect channel activation response message, timer
T9103 timeout, channel instance released, channel force-
released, this counter and C900060016 accumulate
simultaneously.
Measurement After BSC activates TCH/F (due to handover, used for signaling
Point channel), this counter accumulates when CHL_ACT_ACK
message sent by BTS is received correctly, channel activation
failure message is received, channel activation response
message is not correct, timer T9103 times out, channel instance
is released, or channel is forcibly released.
(C901260011+C900060016) The measurement points are C3
and D3, as shown in Figure 16, Figure 17, Figure 18, and Figure
19.
Unit Times

C901260011
Definition Number of signaling TCH/F allocation success for handover
Description This counter counts the number of signaling TCH/F allocation
success during handover of signaling channel.
After BSC responds channel request message allocation and
successfully seizes channel, BSC sends channel activation
message CHL_ACT to BTS to activate this TCH/F. if activation
success, CHL_ACT_ACK message sent by BTS will be received,
indicating TCH/F allocation success, this counter accumulates.
Measurement This counter accumulates when CHL_ACT_ACK correctly receives
Point CHL_ACT_ACK message sent by BTS due to handover and used
for signaling channel. The measurement points are C3 and D3,
as shown in Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

C901260013
Definition Number of signaling TCH/F assignment attempts for assignment
Description

40 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

This counter counts the number of signaling TCH/F assignment


success during assignment of TCH/F channel.
After BSC responds channel request message allocation and
successfully seizes channel, BSC sends channel activation
message CHL_ACT to BTS to activate this TCH/F. For immediate
assignment, after activation success, BTS receives MS access
and sends EST_IND message to BSC, this counter accumulates
while BSC correctly receives this message; if MS access can’t be
received within specified duration, this assignment is failed.
Measurement For immediate assignment, this counter accumulates when BSC
Point correctly receives EST_IND message or T3101 times out (that is,
MS access notice can’t be received within specified duration).
The measurement point is A3, as shown in Figure 13.
Unit Times

C901260016
Definition Number of signaling TCH/F handover attempt
Description This counter counts the number of signaling TCH/F handover
attempts, including the number of TCH/F handover success
(C901260017), the number of TCH/F handover failure with
return (C901260018), and the number of TCH/F handover failure
without return (C901260019).
This counter and C901260017 accumulate when BSC detects the
handover success message sent by MS on reallocated TCH/F
channel; this counter and C901260018 accumulate when
handover failure message is received; this counter and
C901260019 accumulate when it receives the message of
exception, released instance, force-released instance, or timer
timeout.
For intra-cell handover, handover success symbolic message is
ASS_COM; for inter-cell handover and external handover,
handover success symbolic message is HO_COM. For intra-cell
and inter-cell handover, this counter accumulates on the basis of
source instance; for external handover, this counter accumulates
on target instance because source instance doesn’t at this BSC
side.
Measurement This counter accumulates when BSC detects handover success
Point message, ASS_COM/HO_COM, sent from reallocated TCH/F
channel, or receives failure message, ASS_FAIL/HO_FAIL,, or
receives message of exception, released instance, force-
released instance, or timer timeout. The measurement points
are C4 and D4, as shown in Figure 16, Figure 17, Figure 18,
and Figure 19.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 41


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901260017
Definition Number of signaling TCH/F handover success
Description This counter counts the number of signaling TCH/F handover
success during handover of signaling channel.
This counter accumulates when handover success message sent
from MS is detected on reallocated TCH/F channel.
For intra-cell handover, handover success symbolic message is
ASS_COM; for inter-cell handover and external handover,
handover success symbolic message is HO_COM. For intra-cell
and inter-cell handover, this counter accumulates on the basis of
source instance; for external handover, this counter accumulates
on target instance because source instance doesn’t at this BSC
side.
Measurement BSC receives ASS_COM or HO_COM message. The measurement
Point points are C4 and D4, as shown in Figure 16, Figure 17, Figure
18, and Figure 19.
Unit Times

C901260018
Definition Number of signaling TCH/F handover failure with reconnection
Description This counter counts the number of signaling TCH/F handover
failure during handover of signaling channel.
This counter accumulates when MS conducts handover on TCH/F
channel, returns to previous channel after failed to access to
new channel, receives assignment failure or handover failure
from previous channel.
Measurement BSC receives ASS_FAIL or HO_FAIL message. The measurement
Point points are C4 and D4, as shown in Figure 20, Figure 21.

42 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

FIGURE 20 - INTERNAL H ANDOVER (INTERNAL TC INTRA-CELL HANDOVER)


FAILURE FLOW 1

FIGURE 21 - EXTERNAL H ANDOVER FAILURE FLOW (INTERNAL TC)

Unit Times

C901260019
Definition Number of signaling TCH/F handover failure without
reconnection
Description

Confidential and Proprietary Information of ZTE CORPORATION 43


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

This counter counts the number of signaling TCH/F handover


failure without reconnection during handover of signaling
channel.
This counter accumulates when MS handover fails or it can’t
return to previous channel after BSC sends assignment
command or handover command to MS.
Measurement This counter accumulates when BSC receives messages of
Point exception, released instance, force-released instance, or timer
timeout. The measurement point is C4, as shown in Figure 22,
Figure 23.

FIGURE 22 - INTERNAL H ANDOVER (INTERNAL TC INTRA-CELL HANDOVER)


FAILURE FLOW 2

FIGURE 23 - INTERNAL H ANDOVER (INTERNAL TC INTRA-CELL HANDOVER)


FAILURE FLOW 3

Unit Times

C901260021
Definition Number of voice TCH/F seizure success for assignment

44 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

Description This counter counts the number of voice TCH/F seizure success
during assignment of signaling channel.
After BSC receives channel request message, it will try to
allocate channel for this request. If allocation and seizure
succeed, this counter accumulates. If no channel is returned
after application but queuing or force release can be conducted,
it will enter into the state to wait for resource, this counter
accumulates when corresponding resource occurs.
Measurement BSC successfully applies for channel (due to assignment, used
Point for voice channel) and does successful seizure, or BSC receives
internal waiting resource effective message. The measurement
point is B1, as shown in Figure 14, Figure 15.
Unit Times

C901260024
Definition Number of voice TCH/F seizure success for handover
Description This counter counts the number of voice TCH/F seizure success
during handover of signaling channel.
After BSC receives channel request message, it will try to
allocate channel for this request. If allocation and seizure
succeed, this counter accumulates. If no channel is returned
after application but queuing or force release can be conducted,
it will enter into the state to wait for resource, this counter
accumulates when corresponding resource occurs.
Measurement BSC successfully applies for channel (due to handover, used for
Point voice channel) and does successful seizure, or BSC receives
internal waiting resource effective message. The measurement
points are C1 and D1, as shown in Figure 16, Figure 17, Figure
18, and Figure 19.
Unit Times

C901260026
Definition Number of TCH/F allocation attempts for assignment (speech
version 1)
Description This counter counts the number of TCH/F allocation attempts
when assigning voice channel (for speech version 1), including
the number of allocation success (C900060023) and failure
(C900060024+C900060138+ C900060139+ C900060140).
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC firstly finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate this TCH/F. if activation succeeds, BSC will
receive CHL_ACT_ACK message sent by BTS, indicating TCH/F

Confidential and Proprietary Information of ZTE CORPORATION 45


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

allocation success, this counter and C900060023 accumulate


simultaneously; reversely, if failed, this counter and the counter
that corresponds to failure will accumulate simultaneously.
Measurement This counter accumulates when allocation succeeds or fails (due
Point to assignment, used for voice channel, using speech version 1).
The measurement points are B2 and B3, as shown in Figure 14,
Figure 15.
Unit Times

C901260032
Definition Number of TCH/F allocation attempts by BSC for handover
(speech version 1)
Description This counter counts the number of TCH/F allocation attempts
during handover of voice channel (for speech version 1),
including the number of allocation success (C901260033) and
failure (C900060156+C900060157+C900060158+C900060159).
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC firstly finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate this TCH/F. if activation succeeds, BSC will
receive CHL_ACT_ACK message sent by BTS, indicating TCH/F
allocation success, this counter and C901260033 accumulate
simultaneously; reversely, if failed, this counter and the counter
that corresponds to failure will accumulate simultaneously.
Measurement This counter accumulates when allocation succeeds or fails (due
Point to handover, used for voice channel, using speech version 1).
The measurement points are C3 and D3, as shown in Figure 16,
Figure 17, Figure 18, and Figure 19.
Unit Times

C901260033
Definition Number of TCH/F allocation success by BSC for handover(speech
version 1)
Description This counter counts the number of TCH/F allocation success
during handover of voice channel (for speech version 1).
After BSC responds channel request message allocation and
successfully seizes channel, BSC sends channel activation
message CHL_ACT to BTS to activate this TCH/F. if activation
success, CHL_ACT_ACK message sent by BTS will be received,
indicating TCH/F allocation success, this counter accumulates.
Measurement This counter accumulates when BSC correctly receives
Point CHL_ACT_ACK message sent by BTS due to handover and used
for voice channel (for speech version 1). The measurement

46 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

points are C3 and D3, as shown in Figure 16, Figure 17, Figure
18, and Figure 19.
Unit Times

C901260038
Definition Number of TCH/F allocation attempts for assignment (speech
version 2)
Description This counter counts the number of TCH/F allocation attempts
when assigning voice channel (for speech version 2), including
the number of allocation success (C900060025) and failure
(C900060141+C900060142+C900060143+C900060144).
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC firstly finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate this TCH/F. if activation succeeds, BSC will
receive CHL_ACT_ACK message sent by BTS, indicating TCH/F
allocation success, this counter and C900060025 accumulate
simultaneously; reversely, if failed, this counter and the counter
that corresponds to failure will accumulate simultaneously.
Measurement This counter accumulates when allocation succeeds or fails (due
Point to assignment, used for voice channel, using speech version 2).
The measurement points are B2 and B3, as shown in Figure 14,
Figure 15.
Unit Times

C901260044
Definition Number of TCH/F allocation attempts by BSC for handover
(speech version 2)
Description This counter counts the number of TCH/F allocation attempts
during handover of voice channel (for speech version 2),
including the number of allocation success (C901260045) and
failure (C900060160+C900060161+C900060162+C900060163).
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC firstly finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate this TCH/F. if activation succeeds, BSC will
receive CHL_ACT_ACK message sent by BTS, indicating TCH/F
allocation success, this counter and C901260045 accumulate
simultaneously; reversely, if failed, this counter and the counter
that corresponds to failure will accumulate simultaneously.
Measurement This counter accumulates when allocation succeeds or fails (due
Point to handover, used for voice channel, using speech version 2).
The measurement points are C3 and D3, as shown in Figure 16,
Figure 17, Figure 18, and Figure 19.

Confidential and Proprietary Information of ZTE CORPORATION 47


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Unit Times

C901260045
Definition Number of TCH/F allocation success by BSC for handover
(speech version 2)
Description This counter counts the number of TCH/F allocation success
during handover of voice channel (for speech version 2).
After BSC responds channel request message allocation and
successfully seizes channel, BSC sends channel activation
message CHL_ACT to BTS to activate this TCH/F. if activation
success, CHL_ACT_ACK message sent by BTS will be received,
indicating TCH/F allocation success, this counter accumulates.
Measurement This counter accumulates when BSC correctly receives
Point CHL_ACT_ACK message sent by BTS due to handover and used
for voice channel (for speech version 2). The measurement
points are C3 and D3, as shown in Figure 16, Figure 17, Figure
18, and Figure 19.
Unit Times

C901260050
Definition Number of TCH/F allocation attempts for assignment (speech
version 3)
Description This counter counts the number of TCH/F allocation attempts
when assigning voice channel (for speech version 3), including
the number of allocation success (C900060026) and failure
(C900060027+C900060145+C900060146+C900060147).
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC firstly finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate this TCH/F. if activation succeeds, BSC will
receive CHL_ACT_ACK message sent by BTS, indicating TCH/F
allocation success, this counter and C900060026 accumulate
simultaneously; reversely, if failed, this counter and the counter
that corresponds to failure will accumulate simultaneously.
Measurement This counter accumulates when allocation succeeds or fails (due
Point to assignment, used for voice channel, using speech version 3).
The measurement points are B2 and B3, as shown in Figure 14,
Figure 15.
Unit Times

48 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

C901260056
Definition Number of TCH/F allocation attempts by BSC for handover
(speech version 3)
Description This counter counts the number of TCH/F allocation attempts
during handover of voice channel (for speech version 3),
including the number of allocation success (C901260057) and
failure (C900060164+C900060165+C900060166+C900060167).
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC firstly finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate this TCH/F. if activation succeeds, BSC will
receive CHL_ACT_ACK message sent by BTS, indicating TCH/F
allocation success, this counter and C901260057 accumulate
simultaneously; reversely, if failed, this counter and the counter
that corresponds to failure will accumulate simultaneously.
Measurement This counter accumulates when allocation succeeds or fails (due
Point to handover, used for voice channel, using speech version 3).
The measurement points are C3 and D3, as shown in Figure 16,
Figure 17, Figure 18, and Figure 19.
Unit Times

C901260057
Definition Number of TCH/F allocation success by BSC for handover
(speech version 3)
Description This counter counts the number of TCH/F allocation success
during handover of voice channel (for speech version 3).
After BSC responds channel request message allocation and
successfully seizes channel, BSC sends channel activation
message CHL_ACT to BTS to activate this TCH/F. if activation
success, CHL_ACT_ACK message sent by BTS will be received,
indicating TCH/F allocation success, this counter accumulates.
Measurement This counter accumulates when BSC correctly receives
Point CHL_ACT_ACK message sent by BTS due to handover and used
for voice channel (for speech version 3). The measurement
points are C3 and D3, as shown in Figure 16, Figure 17, Figure
18, and Figure 19.
Unit Times

C901260062
Definition Number of voice TCH/F assignment attempts by BSC
Description

Confidential and Proprietary Information of ZTE CORPORATION 49


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

This counter counts the number of voice TCH/F assignment


attempts when assigning TCH/F channel as voice channel,
including the number of assignment success (C900060028) and
failure (C900060029).
After BSC responds channel request message allocation and
successfully seizes channel, BSC sends channel activation
message CHL_ACT to BTS to activate this TCH/F. For the
assignment form port A, this counter and C900060028
accumulate simultaneously after receiving assignment success
message. This counter and C900060029 accumulate
simultaneously if MS access notice can’t be received within
specified duration, that is, this assignment failed at this time.
Measurement For the assignment from port A, BSC receives the messages of
Point assignment success, assignment failure, timer timeout,
exception, released instance, or force-released instance. The
measurement point is B5, as shown in Figure 14, Figure 15.
Unit Times

C901260065
Definition Number of voice TCH/F handover attempts
Description This counter counts the number of voice TCH/F handover
attempts, including the number of TCH/F handover success
(C900060168), the number of TCH/F handover failure with
return (C901260067), and the number of TCH/F handover failure
without return (C901260068).
During handover, after MS is successfully accessed from new
channel, BSC will receive assignment completion message
ASS_COM (intra-cell handover) or HO_COM message (inter-cell
handover and external handover).
If BSC receives above mentioned messages within specified
duration, it indicates handover success, this counter and
C900060168 accumulate simultaneously; if BSC receives
HO_FAILURE, it is handover failure with response, this counter
and C901260067 accumulate; if handover is failed and BSC can’t
receive HO_FAILURE, it is handover failure without response,
this counter and C901260068 accumulate simultaneously.
For intra-cell and inter-cell handover, this counter accumulates
on the basis of source instance; for external handover, this
counter accumulates on target instance because source instance
doesn’t at this BSC side.
Measurement This counter accumulates when BSC receives
Point ASS_COM/HO_COM message, ASS_FAIL/HO_FAIL message, or
messages of exception, released instance, force-released
instance, or timer timeout. The measurement points are C4 and
D4, as shown in Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

50 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

C901260067
Definition Number of Voice TCH/F handover failure
Description This counter counts the number of voice TCH/F handover failure
during handover of voice channel.
This counter accumulates when MS conducts handover on TCH/F
channel, fails to access to new channel and returns to previous
channel, receives assignment failure or handover failure from
previous channel.
Measurement BSC receives ASS_FAIL or HO_FAIL message. The measurement
Point points are C4 and D4, as shown in Figure 20, Figure 21.
Unit Times

C901260068
Definition Number of Voice TCH/F handover failure messages do not
received by BSC
Description This counter counts the number of voice TCH/F handover failure
without response during handover of voice channel.
This counter accumulates when handover fails or it can’t return
to source channel after BSC sends assignment / handover
command to MS.
Measurement This counter accumulates when BSC receives messages of
Point exception, timer timeout, released instance, or force-released
instance. The measurement points are C4 and D4, as shown in
Figure 22, Figure 23.
Unit Times

C901260070
Definition Number of data TCH/F seizure success for assignment
Description This counter counts the number of data TCH/F seizure success
during assignment of signaling channel.
After BSC receives channel request message, it will try to
allocate channel for this request. If allocation and seizure
succeed, this counter accumulates. If no channel is returned
after application but queuing or force release can be conducted,
it will enter into the state to wait for resource, this counter
accumulates when corresponding resource occurs.
Measurement BSC successfully applies for channel (due to assignment, used
Point for data channel) and does successful seizure, or BSC receives
internal waiting resource effective message. The measurement
point is B1, as shown in Figure 14, Figure 15.

Confidential and Proprietary Information of ZTE CORPORATION 51


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Unit Times

C901260073
Definition Number of data TCH/F seizure success for handover
Description This counter counts the number of data TCH/F seizure success
during handover of signaling channel.
After BSC receives channel request message, it will try to
allocate channel for this request. If allocation and seizure
succeed, this counter accumulates. If no channel is returned
after application but queuing or force release can be conducted,
it will enter into the state to wait for resource, this counter
accumulates when corresponding resource occurs.
Measurement BSC successfully applies for channel (due to handover, used for
Point data channel) and does successful seizure, or BSC receives
internal waiting resource effective message. The measurement
points are C1 and D1, as shown in Figure 16, Figure 17, Figure
18, and Figure 19.
Unit Times

C901260075
Definition Number of data TCH/F allocation attempts for assignment
Description This counter counts the number of data TCH/F allocation
attempts when assigning signaling channel, including the
number of allocation success (C900060034) and failure
(C900060035+C900060148+C900060149+C900060150).
Usage After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC firstly finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate this TCH/F. if activation succeeds, BSC will
receive CHL_ACT_ACK message sent by BTS, indicating TCH/F
allocation success, this counter and C900060034 accumulate
simultaneously; reversely, if failed, this counter and the counter
that corresponds to failure will accumulate simultaneously.
Measurement This counter accumulates when allocation succeeds or fails (due
Point to assignment, used for data channel). The measurement points
are B2 and B3, as shown in Figure 14, Figure 15.
Unit Times

C901260081
Definition Number of data TCH/F allocation attempts by BSC for handover

52 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

Description This counter counts the number of data TCH/F allocation


attempts during handover of data channel, including the number
of allocation success (C901260082) and failure
(C900060169+C900060170+C900060171+C900060172).
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC firstly finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate this TCH/F. if activation succeeds, BSC will
receive CHL_ACT_ACK message sent by BTS, indicating TCH/F
allocation success, this counter and C901260082 accumulate
simultaneously; reversely, if failed, this counter and the counter
that corresponds to failure will accumulate simultaneously.
Measurement This counter accumulates when allocation succeeds or fails (due
Point to handover, used for data channel). The measurement points
are C3 and D3, as shown in Figure 16, Figure 17, Figure 18, and
Figure 19.
Unit Times

C901260082
Definition Number of data TCH/F allocation success for handover
Description This counter counts the number of data TCH/F allocation success
during handover of signaling channel.
After BSC responds channel request message allocation and
successfully seizes channel, BSC sends channel activation
message CHL_ACT to BTS to activate this TCH/F. if activation
success, CHL_ACT_ACK message sent by BTS will be received,
indicating TCH/F allocation success, this counter accumulates.
Measurement This counter accumulates when CHL_ACT_ACK correctly receives
Point CHL_ACT_ACK message sent by BTS due to handover and used
for data channel. The measurement points are C3 and D3, as
shown in Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

C901260087
Definition Number of data TCH/F assignment attempts
Description This counter counts the number of voice TCH/F assignment
attempts when assigning TCH/F channel as data channel,
including the number of assignment success (C900060036) and
failure (C900060037).
After BSC responds channel request message allocation and
successfully seizes channel, BSC sends channel activation
message CHL_ACT to BTS to activate this TCH/F. For the
assignment form port A, this counter and C900060036

Confidential and Proprietary Information of ZTE CORPORATION 53


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

accumulate simultaneously after receiving assignment success


message. This counter and C900060037 accumulate
simultaneously if MS access notice can’t be received within
specified duration, that is, this assignment failed at this time.
Measurement For the assignment from port A, BSC receives the messages of
Point assignment success, assignment failure, timer timeout,
exception, released instance, or force-released instance. The
measurement point is B5, as shown in Figure 14, Figure 15.
Unit Times

C901260090
Definition Number of data TCH/F handover attempts
Description This counter counts the number of data TCH/F handover
attempts, including the number of TCH/F handover success
(C901260091), TCH/F response handover failure (C901260092),
and TCH/F response-less handover failure (C901260093).
During handover, after MS is successfully accessed from new
channel, BSC will receive assignment completion message
ASS_COM (intra-cell handover) or HO_COM message (inter-cell
handover and external handover).
If BSC receives above mentioned messages within specified
duration, it indicates handover success, this counter and
C901260091 accumulate simultaneously; if BSC receives
HO_FAILURE, it is handover failure with response, this counter
and C901260092 accumulate; if handover is failed and BSC can’t
receive HO_FAILURE, it is handover failure without response,
this counter and C901260093 accumulate simultaneously.
For intra-cell and inter-cell handover, this counter accumulates
on the basis of source instance; for external handover, this
counter accumulates on target instance because source instance
doesn’t at this BSC side.
Measurement This counter accumulates when BSC receives
Point ASS_COM/HO_COM message, ASS_FAIL/HO_FAIL message, or
messages of exception, released instance, force-released
instance, or timer timeout. The measurement points are C4 and
D4, as shown in Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

C901260092
Definition Number of data TCH/F handover failure
Description This counter counts the number of data TCH/F handover failure
during handover of data channel.

54 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

This counter accumulates when MS conducts handover on TCH/F


channel, fails to access to new channel and returns to previous
channel, receives assignment failure or handover failure from
previous channel.
Measurement BSC receives ASS_FAIL or HO_FAIL message. The measurement
Point points are C4 and D4, as shown in Figure 20, Figure 21.
Unit Times

C901260093
Definition Number of data TCH/F handover failure messages do not
received by BSC
Description This counter counts the number of data TCH/F handover failure
without response during handover of data channel.
This counter accumulates when handover fails or it can’t return
to source channel after BSC sends assignment / handover
command to MS.
Measurement This counter accumulates when BSC receives messages of
Point exception, released instance, force-released instance, or timer
timeout. The measurement point is C4, as shown in Figure 22
and Figure 23.
Unit Times

C901260094
Definition Number of data TCH/F allocation failure for assignment due to
TIPB connection failure (Speech version 1)
Description This counter counts the number of data TCH/F allocation failure
for assignment due to TIPB connection failure (speech version 1)
when assigning voice channel.
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC sends TIU connection
requests to TIPB. This counter accumulates when it receives the
messages of TIU connection failure, incorrect TIU connection
response message, or timer timeout.
Measurement BSC uses TCH/F due to assignment; this counter accumulates
Point when it receives connection failure message, incorrect
connection response message, or timer timeout during TIU
connection. The measurement point is B2, as shown in Figure 24.

Confidential and Proprietary Information of ZTE CORPORATION 55


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

FIGURE 24 - GENERAL ASSIGNMENT FAILURE FLOW 1 (EXTERNAL TC)

Unit Times

C901260095
Definition Number of data TCH/F allocation failure for assignment due to
Resource request to iTC failure (Speech version 1)
Description This counter counts the number of data TCH/F allocation failure
for assignment due to resource request to iTC failure (speech
version 1) when assigning voice channel.
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC requests resource from
iTC. If application of iTC resource fails due to receive the
messages of unavailable iTC resource, incorrect response
message, or timer timeout, this leads to TCH/F assignment
failure, and this counter accumulates.
Measurement BSC uses TCH/F due to assignment; this counter accumulates
Point when it receives the messages of unavailable iTC, incorrect
response message, or timer timeout during iTC resource
application. The measurement point is B1, as shown in Figure 25.

FIGURE 25 - GENERAL ASSIGNMENT FAILURE FLOW 2 (EXTERNAL TC)

56 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

Unit Times

C901260096
Definition Number of data TCH/F allocation failure for handover due to
TIPB connection failure (Speech version 1)
Description This counter counts the number of data TCH/F allocation failure
for handover due to TIPB connection failure (speech version 1)
during handover.
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC sends TIU connection
requests to TIPB. This counter accumulates when it receives the
messages of TIU connection failure, incorrect TIU connection
response message, or timer timeout.
Measurement BSC uses TCH/F due to assignment; this counter accumulates
Point when it receives messages of connection failure, incorrect
connection response, or timer timeout during TIU connection.
The measurement points are C2 and D2, as shown in Figure 26
and Figure 27.

FIGURE 26 - INTERNAL H ANDOVER (EXTERNAL TC INTRA-CELL HANDOVER,


AND CHANNEL TYPES ARE CHANGED) FAILURE FLOW 1

Confidential and Proprietary Information of ZTE CORPORATION 57


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

FIGURE 27 - EXTERNAL H ANDOVER FLOW (EXTERNAL TC)

BSC iTC MSC

HO_REQ

TCRescr Req

TCRescr Ack

D1
iTC Connect Req

iTC Connect NAck

D2
HO_FAIL

Unit Times

C901260097
Definition Number of data TCH/F allocation failure for handover due to
Resource request to iTC failure (Speech version 1)
Description This counter counts the number of data TCH/F allocation failure
for handover due to resource request to iTC failure (speech
version 1) during handover of voice channel.
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC requests TC resource
after determining channel types are changed. If application of
iTC resource fails due to receive the messages of unavailable iTC
resource, incorrect response, or timer timeout, this leads to
TCH/F assignment failure, and this counter accumulates.
Measurement BSC uses TCH/F due to handover; this counter accumulates
Point when it receives the messages of unavailable iTC, incorrect
response, or timer timeout during iTC resource application. The
measurement points are C1 and D1, as shown in Figure 28 and
Figure 29.

58 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

FIGURE 28 - INTERNAL H ANDOVER (EXTERNAL TC INTRA-CELL HANDOVER,


AND CHANNEL TYPES ARE CHANGED) FAILURE FLOW 2

FIGURE 29 - EXTERNAL H ANDOVER FAILURE FLOW 2 (EXTERNAL TC)

Unit Times

C901260098
Definition Number of data TCH/F allocation failure for assignment due to
TIPB connection failure (Speech version 2)
Description This counter counts the number of data TCH/F allocation failure
for assignment due to TIPB connection failure (speech version 2)
when assigning voice channel.
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC sends TIU connection
requests to TIPB. This counter accumulates when it receives the
messages of TIU connection failure, incorrect TIU connection
response message, or timer timeout.
Measurement BSC uses TCH/F due to assignment; this counter accumulates
Point when it receives connection failure message, incorrect
connection response message, or timer timeout during TIU
connection. The measurement point is B2, as shown in Figure 24.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 59


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901260099
Definition Number of data TCH/F allocation failure for assignment due to
Resource request to iTC failure (Speech version 2)
Description This counter counts the number of data TCH/F allocation failure
for assignment due to resource request to iTC failure (speech
version 2) when assigning voice channel.
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC requests resource from
iTC. If application of iTC resource fails due to receive the
messages of unavailable iTC resource, incorrect response
message, or timer timeout, this leads to TCH/F assignment
failure, and this counter accumulates.
Measurement BSC uses TCH/F due to assignment; this counter accumulates
Point when it receives the messages of unavailable iTC, incorrect
response message, or timer timeout during iTC resource
application. The measurement point is B1, as shown in Figure 25.
Unit Times

C901260100
Definition Number of data TCH/F allocation failure for handover due to
TIPB connection failure (Speech version 2)
Description This counter counts the number of data TCH/F allocation failure
for handover due to TIPB connection failure (speech version 2)
during handover.
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC sends TIU connection
requests to TIPB. This counter accumulates when it receives the
messages of TIU connection failure, incorrect TIU connection
response message, or timer timeout.
Measurement BSC uses TCH/F due to assignment; this counter accumulates
Point when it receives messages of connection failure, incorrect
connection response, or timer timeout during TIU connection.
The measurement points are C2 and D2, as shown in Figure 26
and Figure 27.
Unit Times

C901260101
Definition Number of data TCH/F allocation failure for handover due to
Resource request to iTC failure (Speech version 2)
Description

60 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

This counter counts the number of data TCH/F allocation failure


for handover due to resource request to iTC failure (speech
version 2) during handover of voice channel.
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC requests TC resource
after determining channel types are changed. If application of
iTC resource fails due to receive the messages of unavailable iTC
resource, incorrect response, or timer timeout, this leads to
TCH/F assignment failure, and this counter accumulates.
Measurement BSC uses TCH/F due to handover; this counter accumulates
Point when it receives the messages of unavailable iTC resource,
incorrect response message, or timer timeout during iTC
resource application. The measurement points are C1 and D1, as
shown in Figure 28 and Figure 29.
Unit Times

C901260102
Definition Number of data TCH/F allocation failure for assignment due to
TIPB connection failure (Speech version 3)
Description This counter counts the number of data TCH/F allocation failure
for assignment due to TIPB connection failure (speech version 3)
when assigning voice channel.
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC sends TIU connection
requests to TIPB. This counter accumulates when it receives the
messages of TIU connection failure, incorrect TIU connection
response message, or timer timeout.
Measurement BSC uses TCH/F due to assignment; this counter accumulates
Point when it receives connection failure message, incorrect
connection response message, or timer timeout during TIU
connection. The measurement point is B2, as shown in Figure 24.
Unit Times

C901260103
Definition Number of data TCH/F allocation failure for assignment due to
resource request to iTC failure (Speech version 3)
Description This counter counts the number of data TCH/F allocation failure
for assignment due to resource request to iTC failure (speech
version 3) when assigning voice channel.
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC requests resource from
iTC. If application of iTC resource fails due to receive the
messages of unavailable iTC resource, incorrect response

Confidential and Proprietary Information of ZTE CORPORATION 61


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

message, or timer timeout, this leads to TCH/F assignment


failure, and this counter accumulates.
Measurement BSC uses TCH/F due to assignment; this counter accumulates
Point when it receives the messages of unavailable iTC resource,
incorrect response message, or timer timeout during iTC
resource application. The measurement point is B1, as shown in
Figure 25.
Unit Times

C901260104
Definition Number of data TCH/F allocation failure for handover due to
TIPB connection failure (Speech version 3)
Description This counter counts the number of data TCH/F allocation failure
for handover due to TIPB connection failure (speech version 3)
during handover.
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC sends TIU connection
requests to TIPB. This counter accumulates when it receives the
messages of TIU connection failure, incorrect TIU connection
response message, or timer timeout.
Measurement BSC uses TCH/F due to assignment; this counter accumulates
Point when it receives messages of connection failure, incorrect
connection response, or timer timeout during TIU connection.
The measurement points are C2 and D2, as shown in Figure 26
and Figure 27.
Unit Times

C901260105
Definition Number of data TCH/F allocation failure for handover due to
Resource request to iTC failure (Speech version 3)
Description This counter counts the number of data TCH/F allocation failure
for handover due to resource request to iTC failure (speech
version 3) during handover of voice channel.
After BSC responds channel request message allocation and
successfully seizes TCH/F channel, BSC requests TC resource
after determining channel types are changed. If application of
iTC resource fails due to receive the messages of unavailable iTC
resource, incorrect response, or timer timeout, this leads to
TCH/F assignment failure, and this counter accumulates.
Measurement BSC uses TCH/F due to handover; this counter accumulates
Point when it receives the messages of unavailable iTC resource,
incorrect response message, or timer timeout during iTC

62 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

resource application. The measurement points are C1 and D1, as


shown in Figure 28 and Figure 29.
Unit Times

C901260106
Definition Number of TCH/F allocation failure due to request AIPB resource
failure for assignment (speech version 1)
Description This counter counts the number of TCH/F allocation failure due
to request AIPB resource failure for assignment.
This counter increments while BSC receives assignment requests
(speech version 1) to apply for AIPB board resource from
database, failed request (including database return failure or no
AIPB board resource) indicates TCH/F allocation failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request AIPB resource failure for assignment.
Measurement This counter increments while BSC correctly receives database
point return failure or no AIPB board resource, and the reason to
apply for channel is assignment and purpose is voice channel.
The measurement point is A as shown in Figure 30.

FIGURE 30 - REQUEST RESOURCE FAILURE

CS control
CS控制面 Database
数据库
plane
Request
申请资源 resource

Request resource
申请资源失败
failure
A

Unit Times

C901260107
Definition Number of TCH/F allocation failure due to request UDP port
failure for assignment (speech version 1)
Description This counter counts the number of TCH/F channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(speech version 1), access request is sent to access module, if
access module returns access failure due to UDP port request
failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request UDP port failure.

Confidential and Proprietary Information of ZTE CORPORATION 63


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Measurement This counter increments while BSC correctly receives


point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for
assignment. The measurement point is A as shown in Figure 31.

FIGURE 31 - CHANNEL ALLOCATION FAILURE

MSC BSC

ASSIGN REQ

Unit Times

C901260108
Definition Number of TCH/F allocation failure due to AIPB connection
failure for assignment (speech version 1)
Description This counter counts the number of TCH/F channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(speech version 1), access request is sent to access module, if
access module returns access failure due to UDP port request
failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for assignment. The measurement point is A as shown
in Figure 31.
Unit Times

C901260109
Definition Number of TCH/F allocation failure due to request AIPB resource
failure for handover (speech version 1)
Description This counter counts the number of TCH/F allocation failure due
to request AIPB resource failure for assignment.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 1), the reason to request channel is handover, to
request AIPB resource from database. This counter increments if
failed to request AIPB (including database returning failure or no AIPB
resource), indicating TCH/F allocation failure.

64 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request AIPB resource failure for assignment.
Measurement This counter increments while BSC correctly receives database
point return failure or no AIPB board resource, and the reason to
apply for channel is handover and purpose is voice channel. The
measurement point is A as shown in Figure 30.
Unit Times

C901260110
Definition Number of TCH/F allocation failure due to request UDP port
failure for handover (speech version 1)
Description This counter counts the number of TCH/F channel allocation
failure due to UDP port failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 1), the reason to request channel is handover, to
request access request for access module. This counter increments
while access module returns failure and the reason is failed to request
UDP port.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for handover.
The measurement point is A as shown in Figure 31.
Unit Times

C901260111
Definition Number of TCH/F allocation failure due to AIPB connection
failure for handover (speech version 1)
Description This counter counts the number of TCH/F channel allocation
failure due to AIPB access failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 1), the reason to request channel is handover, to
request access request for access module. This counter increments
while access module returns failure and the reason is failed to access
AIPB.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for handover. The measurement point is A as shown in
Figure 31.

Confidential and Proprietary Information of ZTE CORPORATION 65


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Unit Times

C901260112
Definition Number of TCH/F allocation failure due to request AIPB resource
failure for assignment (speech version 2)
Description This counter counts the number of TCH/F allocation failure due
to request AIPB resource failure for assignment.
This counter increments while BSC receives assignment requests
(speech version 2) to apply for AIPB board resource from
database, failed request (including database return failure or no
AIPB board resource) indicates TCH/F allocation failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request AIPB resource failure for assignment.
Measurement This counter increments while BSC correctly receives database
point return failure or no AIPB board resource, and the reason to
apply for channel is assignment and purpose is voice channel.
The measurement point is A as shown in Figure 30
Unit Times

C901260113
Definition Number of TCH/F allocation failure due to request UDP port
failure for assignment (speech version 2)
Description This counter counts the number of TCH/F channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(speech version 2), access request is sent to access module, if
access module returns access failure due to UDP port request
failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for
assignment. The measurement point is A as shown in Figure 31.
Unit Times

C901260114
Definition Number of TCH/F allocation failure due to AIPB connection
failure for assignment (speech version 2)

66 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

Description This counter counts the number of TCH/F channel allocation


failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(speech version 2), access request is sent to access module, if
access module returns access failure due to UDP port request
failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for assignment. The measurement point is A as shown
in Figure 31.
Unit Times

C901260115
Definition Number of TCH/F allocation failure due to request AIPB resource
failure for handover (speech version 2)
Description This counter counts the number of TCH/F allocation failure due
to request AIPB resource failure for assignment.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 2), the reason to request channel is handover, to
request AIPB resource from database. This counter increments if
failed to request AIPB (including database returning failure or no AIPB
resource), indicating TCH/F allocation failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request AIPB resource failure for assignment.
Measurement This counter increments while BSC correctly receives database
point return failure or no AIPB board resource, and the reason to
apply for channel is handover and purpose is voice channel. The
measurement point is A as shown in Figure 30
Unit Times

C901260116
Definition Number of TCH/F allocation failure due to request UDP port
failure for handover (speech version 2)
Description This counter counts the number of TCH/F channel allocation
failure due to UDP port failure during handover.
This counter increments while BSC receives
EV_RANUMC_RADIO_APPLY message (speech version 2) to
request channel due to handover, access request is sent to
access module, if access module returns access failure due to
UDP port request failure.

Confidential and Proprietary Information of ZTE CORPORATION 67


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for handover.
The measurement point is A as shown in Figure 31.
Unit Times

C901260117
Definition Number of TCH/F allocation failure due to AIPB connection
failure for handover (speech version 2)
Description This counter counts the number of TCH/F channel allocation
failure due to AIPB access failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 2), the reason to request channel is handover, to
request access request for access module. This counter increments
while access module returns failure and the reason is failed to access
AIPB.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for handover. The measurement point is A as shown in
Figure 31.
Unit Times

C901260118
Definition Number of TCH/F allocation failure due to request AIPB resource
failure for assignment (speech version 3)
Description This counter counts the number of TCH/F allocation failure due
to request AIPB resource failure for assignment.
This counter increments while BSC receives assignment requests
(speech version 3) to apply for AIPB board resource from
database, failed request (including database return failure or no
AIPB board resource) indicates TCH/F allocation failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request AIPB resource failure for assignment.
Measurement This counter increments while BSC correctly receives database
point return failure or no AIPB board resource, and the reason to
apply for channel is assignment and purpose is voice channel.
The measurement point is A as shown in Figure 30.

68 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

Unit Times

C901260119
Definition Number of TCH/F allocation failure due to request UDP port
failure for assignment (speech version 3)
Description This counter counts the number of TCH/F channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(speech version 3), access request is sent to access module, if
access module returns access failure due to UDP port request
failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for
assignment. The measurement point is A as shown in Figure 31.
Unit Times

C901260120
Definition Number of TCH/F allocation failure due to AIPB connection
failure for assignment (speech version 3)
Description This counter counts the number of TCH/F channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(speech version 3), access request is sent to access module, if
access module returns access failure due to UDP port request
failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for assignment. The measurement point is A as shown
in Figure 31.
Unit Times

C901260121
Definition Number of TCH/F allocation failure due to request AIPB resource
failure for handover (speech version 3)

Confidential and Proprietary Information of ZTE CORPORATION 69


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Description This counter counts the number of TCH/F allocation failure due
to request AIPB resource failure for assignment.
This counter increments while BSC receives
EV_RANUMC_RADIO_APPLY message (speech version 3), the
reason to request channel is handover and request AIPB
resource from database, if request AIPB fails (including database
return failure or no AIPB resource), indicating TCH/F allocation
failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request AIPB resource failure for assignment.
Measurement This counter increments while BSC correctly receives database
point return failure or no AIPB board resource, and the reason to
apply for channel is handover and purpose is voice channel. The
measurement point is A as shown in Figure 30.
Unit Times

C901260122
Definition Number of TCH/F allocation failure due to request UDP port
failure for handover (speech version 3)
Description This counter counts the number of TCH/F channel allocation
failure due to UDP port failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 3), the reason to request channel is handover, to
request access request for access module. This counter increments
while access module returns failure and the reason is failed to request
UDP port.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for handover.
The measurement point is A as shown in Figure 31.
Unit Times

C901260123
Definition Number of TCH/F allocation failure due to AIPB connection
failure for handover (speech version 3)
Description This counter counts the number of TCH/F channel allocation
failure due to AIPB access failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 3), the reason to request channel is handover, to
request access request for access module. This counter increments

70 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

while access module returns failure and the reason is failed to access
AIPB.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for handover. The measurement point is A as shown in
Figure 31.
Unit Times

C901260124
Definition Number of TCH/F allocation failure due to request AIPB resource
failure for assignment (data)
Description This counter counts the number of TCH/F allocation failure due
to request AIPB resource failure for assignment.
This counter increments while BSC receives assignment requests
(data) to apply for AIPB board resource from database, failed
request (including database return failure or no AIPB resource)
indicates TCH/F allocation failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request AIPB resource failure for assignment.
Measurement This counter increments while BSC correctly receives database
point return failure or no AIPB board resource, and the reason to
apply for channel is assignment and purpose is voice channel.
The measurement point is A as shown in Figure 30.
Unit Times

C901260125
Definition Number of TCH/F allocation failure due to request UDP port
failure for assignment (data)
Description This counter counts the number of TCH/F channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(data), access request is sent to access module, if access
module returns access failure due to UDP port request failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for
assignment. The measurement point is A as shown in Figure 31.

Confidential and Proprietary Information of ZTE CORPORATION 71


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Unit Times

C901260126
Definition Number of TCH/F allocation failure due to AIPB connection
failure for assignment (data)
Description This counter counts the number of TCH/F channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(data), access request is sent to access module, if access
module returns access failure due to UDP port request failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for assignment. The measurement point is A as shown
in Figure 31.
Unit Times

C901260127
Definition Number of TCH/F allocation failure due to request AIPB resource
failure for handover (data)
Description This counter counts the number of TCH/F allocation failure due
to request AIPB resource failure for assignment.
When BSC receives EV_RANUMC_RADIO_APPLY message (data),
the reason to request channel is handover, to request AIPB
resource from database. This counter increments if failed to
request AIPB (including database returning failure or no AIPB
resource), indicating TCH/F allocation failure.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request AIPB resource failure for assignment.
Measurement This counter increments while BSC correctly receives database
point return failure or no AIPB board resource, and the reason to
apply for channel is handover and purpose is voice channel. The
measurement point is A as shown in Figure 30
Unit Times

C901260128
Definition Number of TCH/F allocation failure due to request UDP port
failure for handover (data)

72 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

Description This counter counts the number of TCH/F channel allocation


failure due to UDP port failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (data),
the reason to request channel is handover, to request access
request for access module. This counter increments while access
module returns failure and the reason is failed to request UDP port.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for handover.
The measurement point is A as shown in Figure 31.
Unit Times

C901260129
Definition Number of TCH/F allocation failure due to AIPB connection
failure for handover (data)
Description This counter counts the number of TCH/F channel allocation
failure due to AIPB access failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (data),
the reason to request channel is handover, to request access
request for access module. This counter increments while access
module returns failure and the reason is failed to access AIPB.
Usage This counter is used to find out the frequency of TCH/F allocation
failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for handover. The measurement point is A as shown in
Figure 31.
Unit Times

C901260130
Definition Number of assign TCH/F release by forced handover to forced
handover source
Description When the BSC CS service instance is forcibly handover, this
counter counts the number of times that the released TCH/F
resource is assigned to the forced handover source.
The BSC CS service instance is forcibly handover to release
resource, if the released TCH/F resource is assigned to the
forced handover source, the counter accumulates.

Confidential and Proprietary Information of ZTE CORPORATION 73


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Usage This counter is used to find out the frequency of the TCH/F
released by forced handover being assigned to the forced
handover source.
Measurement The BSC CS service instance is forcibly handover to release
point resource, if the released TCH/F resource is assigned to the
forced handover source, the counter accumulates.
Unit Times

C901260131
Definition Number of assign TCH/F release by forced handover to queuing
user
Description When the BSC CS service instance is forcibly handover, this
counter counts the number of times that the released TCH/F
resource is assigned to the queuing user.
The BSC CS service instance is forcibly handover to release
resource, if the released TCH/F resource is assigned to the
queuing user, the counter accumulates.
Usage This counter is used to find out the frequency of the TCH/F
released by forced handover being assigned to the queuing user.
Measurement The BSC CS service instance is forcibly handover to release
point resource, if the released TCH/F resource is assigned to the
queuing user, the counter accumulates.
Unit Times

C901260132
Definition Number of restore TCH/F release by forced handover to DBS
Description When the BSC CS service instance is forcibly handover, this
counter counts the number of times that the released TCH/F
resource is restored to the database instead of being assigned to
other users.
The BSC CS service instance is forcibly handover to release
resource, if the released TCH/F resource is just released instead
of being assigned to other users, the counter accumulates.
Usage This counter is used to find out the frequency of the TCH/F
released by forced handover being restored to DBS.
Measurement The BSC CS service instance is forcibly handover to release
point resource, if the released TCH/F resource is just released instead
of being assigned to other users, the counter accumulates.
Unit Times

74 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - TCH/F Measurement

C901260133
Definition Number of assign TCH/F release by forced release to forced
release source
Description When the BSC CS service instance is forcibly released, this
counter counts the number of times that the released TCH/F
resource is assigned to the forced release source.
The BSC CS service instance is forcibly released to release
resource, if the released TCH/F resource is assigned to the
forced release source, the counter accumulates.
Usage This counter is used to find out the frequency of the TCH/F
released by forced release being assigned to the forced release
source.
Measurement The BSC CS service instance is forcibly released to release
point resource, if the released TCH/F resource is assigned to the
forced release source, the counter accumulates.
Unit Times

C901260134
Definition Number of assign TCH/F release by forced release to queuing
user
Description When the BSC CS service instance is forcibly released, this
counter counts the number of times that the released TCH/F
resource is assigned to the queuing user.
The BSC CS service instance is forcibly released to release
resource, if the released TCH/F resource is assigned to the
queuing user, the counter accumulates.
Usage This counter is used to find out the frequency of the TCH/F
released by forced release being assigned to the queuing user.
Measurement The BSC CS service instance is forcibly released to release
point resource, if the released TCH/F resource is assigned to the
queuing user, the counter accumulates.
Unit Times

C901260135
Definition Number of restore TCH/F release by forced release to DBS
Description When the BSC CS service instance is forcibly released, this
counter counts the number of times that the released TCH/F
resource is restored to the database instead of being assigned to
other users.

Confidential and Proprietary Information of ZTE CORPORATION 75


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

The BSC CS service instance is forcibly released to release


resource, if the released TCH/F resource is just released instead
of being assigned to other users, the counter accumulates.
Usage This counter is used to find out the frequency of the TCH/F
released by forced release being restored to DBS.
Measurement The BSC CS service instance is forcibly released to release
point resource, if the released TCH/F resource is just released instead
of being assigned to other users, the counter accumulates.
Unit Times

76 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4

TCH/H Measurement

This chapter contains detailed information about counters


related to TCH/H measurement.

Overview
During GSM BSC signaling system, the allocation uses of TCH/H
channel mainly exist in assignment and handover processes. The
assignment processes include immediate assignment, general
assignment; handover processes include inner handover and
outer handover.
The measurement point of TCH/H counters in immediate
assignment process is shown in Figure 13.
When TC is internal and external, the measurement point of
TCH/H counter in general assignment processes is shown in
Figure 14 and Figure 15.
When TC is internal and external, the measurement point of
TCH/H counter in inner handover process is shown in Figure 16
and Figure 17.
When TC is internal and external, the measurement point of
TCH/H counter in outer handover process is shown in Figure 18
and Figure 19.

TCH/H Measurement Counter Index


Table 8 lists counters related to TCH/H measurement.

TABLE 8 – TCH/H MEASUREMENT COUNTER

Counter ID What It Counts


Number of signaling TCH/H seizure success for
C901270002
assignment
C901270005 Number of signaling TCH/H seizure success for

Confidential and Proprietary Information of ZTE CORPORATION 77


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Counter ID What It Counts


handover
Number of signaling TCH/H allocation attempts by
C901270007
BSC for assignment
Number of signaling TCH/H allocation success for
C901270008
assignment
Number of signaling TCH/H allocation attempts by
C901270010
BSC due to handover
Number of signaling TCH/H allocation success due
C901270011
to handover
Number of signaling TCH/H allocation failure due to
C901270012
handover
Number of signaling TCH/H assignment attempts
C901270013
by BSC
C901270016 Number of signaling TCH/H handover attempts
C901270017 Number of signaling TCH/H handover success
C901270018 Number of signaling TCH/H handover failure
Number of signaling TCH/H handover failure
C901270019
messages do not received by BSC
Number of voice TCH/H seizure success for
C901270021
assignment
Number of voice TCH/H seizure success for
C901270024
handover
Number of TCH/H allocation attempts for
C901270026
assignment by BSC (speech version 1)
Number of TCH/H allocation failure due to channel
C901270027
activation failure for assignment (speech version 1)
Number of TCH/H allocation attempts by BSC
C901270032
during handover (speech version 1)
Number of TCH/H allocation success during
C901270033
handover (speech version 1)
Number of TCH/H allocation attempts by BSC for
C901270038
assignment (speech version 2)
Number of TCH/H allocation success by BSC for
C901270039
assignment (speech version 2)
Number of TCH/H allocation attempts for handover
C901270044
by BSC (speech version 2)
Number of TCH/H allocation success for handover
C901270045
(speech version 2)
Number of TCH/H allocation attempts for
C901270050
assignment (speech version 3)
Number of TCH/H allocation success for assignment
C901270051
(speech version 3)
Number of TCH/H allocation attempts by BSC for
C901270056
handover (speech version 3)

78 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

Counter ID What It Counts


Number of TCH/H allocation success for handover
C901270057
(speech version 3)
Number of Voice TCH/H assignment attempts by
C901270062
BSC
C901270065 Number of Voice TCH/H handover attempts
C901270067 Number of Voice TCH/H handover failure
C901270068 Number of Voice TCH/H handover failure messages
do not received by BSC
C901270070 Number of data TCH/H seizure success for
assignment
C901270073 Number of data TCH/H seizure success for
handover
C901270075 Number of data TCH/H allocation attempts for
assignment by BSC
C901270076 Number of data TCH/H allocation success for
assignment
C901270081 Number of data TCH/H allocation attempts by BSC
C901270082 Number of data TCH/H allocation success for
handover
C901270087 Number of data TCH/H assignment attempts by
BSC
C901270090 Number of data TCH/H handover attempts
C901270092 Number of data TCH/H handover failure
C901270093 Number of data TCH/H handover failure do not
received by BSC
Number of TCH/H allocation failure for assignment
C901270094
due to TIPB connection failure (Speech version 1)
Number of TCH/H allocation failure for assignment
C901270095 due to Resource request to iTC failure (Speech
version 1)
Number of TCH/H allocation failure for handover
C901270096
due to TIPB connection failure (Speech version 1)
Number of TCH/H allocation failure for handover
C901270097 due to Resource request to iTC failure (Speech
version 1)
Number of TCH/H allocation failure for assignment
C901270098
due to TIPB connection failure (Speech version 2)
Number of TCH/H allocation failure for assignment
C901270099 due to Resource request to iTC failure (Speech
version 2)
Number of TCH/H allocation failure for handover
C901270100
due to TIPB connection failure (Speech version 2)
Number of TCH/H allocation failure for handover
C901270101 due to Resource request to iTC failure (Speech
version 2)

Confidential and Proprietary Information of ZTE CORPORATION 79


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Counter ID What It Counts


Number of TCH/H allocation failure for assignment
C901270102
due to TIPB connection failure (Speech version 3)
Number of TCH/H allocation failure for assignment
C901270103 due to Resource request to iTC failure (Speech
version 3)
Number of TCH/H allocation failure for handover
C901270104
due to TIPB connection failure (Speech version 3)
Number of TCH/H allocation failure for handover
C901270105 due to Resource request to iTC failure (Speech
version 3)
Number of TCH/H allocation failure due to request
C901270106 AIPB resource failure for assignment (speech
version 1)
Number of TCH/H allocation failure due to request
C901270107
UDP port failure for assignment (speech version 1)
Number of TCH/H allocation failure due to AIPB
C901270108 connection failure for assignment (speech version
1)
Number of TCH/H allocation failure due to request
C901270109 AIPB resource failure for handover (speech version
1)
Number of TCH/H allocation failure due to request
C901270110
UDP port failure for handover (speech version 1)
Number of TCH/H allocation failure due to AIPB
C901270111
connection failure for handover (speech version 1)
Number of TCH/H allocation failure due to request
C901270112 AIPB resource failure for assignment (speech
version 2)
Number of TCH/H allocation failure due to request
C901270113
UDP port failure for assignment (speech version 2)
Number of TCH/H allocation failure due to AIPB
C901270114 connection failure for assignment (speech version
2)
Number of TCH/H allocation failure due to request
C901270115 AIPB resource failure for handover (speech version
2)
Number of TCH/H allocation failure due to request
C901270116
UDP port failure for handover (speech version 2)
Number of TCH/H allocation failure due to AIPB
C901270117
connection failure for handover (speech version 2)
Number of TCH/H allocation failure due to request
C901270118 AIPB resource failure for assignment (speech
version 3)
Number of TCH/H allocation failure due to request
C901270119
UDP port failure for assignment (speech version 3)

C901270120 Number of TCH/H allocation failure due to AIPB


connection failure for assignment (speech version

80 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

Counter ID What It Counts


3)
Number of TCH/H allocation failure due to request
C901270121 AIPB resource failure for handover (speech version
3)
Number of TCH/H allocation failure due to request
C901270122
UDP port failure for handover (speech version 3)
Number of TCH/H allocation failure due to AIPB
C901270123
connection failure for handover (speech version 3)
Number of TCH/H allocation failure due to request
C901270124
AIPB resource failure for assignment (data)
Number of TCH/H allocation failure due to request
C901270125
UDP port failure for assignment (data)
Number of TCH/H allocation failure due to AIPB
C901270126
connection failure for assignment (data)
Number of TCH/H allocation failure due to request
C901270127
AIPB resource failure for handover (data)
Number of TCH/H allocation failure due to request
C901270128
UDP port failure for handover (data)
Number of TCH/H allocation failure due to AIPB
C901270129
connection failure for handover (data)
Number of assign TCH/H release by forced
C901270130
handover to forced handover source
Number of assign TCH/H release by forced
C901270131
handover to queuing user
Number of restore TCH/H release by forced
C901270132
handover to DBS
Number of assign TCH/H release by forced release
C901270133
to forced release source
Number of assign TCH/H release by forced release
C901270134
to queuing user
Number of restore TCH/H release by forced release
C901270135
to DBS

C901270002
Definition Number of signaling TCH/H seizure success for assignment
Description This counter counts the number of TCH/H channel being seized
when assigning signaling channel.
After BSC receives request message, it tries to assign channel
for the request. This counter increments when allocation and
seizure succeed.
Measurement BSC applies for channel (due to assignment, it is used for
Point signaling channels) and seizure succeeds. The measurement
point is A1, as shown in Figure 13.

Confidential and Proprietary Information of ZTE CORPORATION 81


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Unit Times

C901270005
Definition Number of signaling TCH/H seizure success for handover.
Description This counter counts the number of TCH/H seizure success in
signaling channel handover.
After BSC receives channel request message, it tries to assign
channel for the request. This counter will accumulate if
assignment and seizure succeed; if application returns no
signaling but it is possible to queue or being forced to disconnect,
it will enter the state of waiting for resource. This counter will
accumulate if waiting succeeds.
Measurement BSC applies for channel (because handover, usage are signaling
Point channels) and seizure succeeds, or it receives inner waiting
resource valid message. The measurement points are C1, D1, as
shown in Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

C901270007
Definition Number of signaling TCH/H assignment attempts by BSC for
assignment
Description This counter counts the number of TCH/H channel attempts
being assigned on allocating signaling channel, including the
number of assignment success (C901270008) and assignment
failure (900060174).
After BSC responds channel request message assignment and
successfully seizes TCH/H channel, BSC send channel activation
message CHL_ACT to BTS to activate the TCH/H. If activation
succeeds, it will receive the CHL_ACT_ACK message sent by BTS,
it indicates TCH/H assignment succeeds, this counter and
C901270008 will accumulate simultaneously. On the contrary, if
channel activation fails due to receiving channel activation
failure message, wrong channel activation response message,
timer T9103 timeout, channel instance being released, channel
being forced to disconnect etc, this counter and C900060174 will
accumulate simultaneously.
Measurement After BSC activates TCH/H (because allocation, usage are
Point signaling channels), it receives the CHL_ACK message sent by
BTS, or receives channel activation failure message, wrong
channel activation response message, timer T9013 timeout,
channel instance being released, channel being forced to
disconnect etc. (C901270008+C900060174). The measurement
point is A2, as shown in Figure 13.
Unit Times

82 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

C901270008
Definition Number of signaling TCH/H allocation success for assignment
Description This counter counts the number of TCH/H channel success
assignment on allocating signaling channel.
After BSC responds channel request messages assignment and
successfully seizures channel, BSC sends channel activation
message CHL_ACT to activate the TCH/H. If activated
successfully, it will receive CHL_ACT_ACK message sent by BTS,
it indicates that TCH/H assigns successfully and the counter
accumulates.
Measurement BSC receives correctly CHL_ACT_ACK message sent by BTS and
Point the reason is that allocation and usage are signaling channel.
The measurement point is A2, as shown in Figure 13.
Unit Times

C901270010
Definition Number of signaling TCH/H allocation attempts by BSC due to
handover
Description This counter counts the number of TCH/H channel attempt being
allocated in signaling channel handover, including successful
allocation times (C901270011) and failed allocation times
(C901270012).
After BSC responds channel request message assignment and
successfully occupies TCH/H channel, BSC send channel
activation message CHL_ACT to BTS to activate the TCH/H. If
activation is successful, it will receive the CHL_ACT_ACK
message sent by BTS, it indicates TCH/H assignment is
successful, this counter and C901270011 will accumulate
simultaneously. On the contrary, if channel activation fails due
to receiving channel activation failure message, wrong channel
activation response message, timer T9103 timeout, channel
instance being released, channel being forced to disconnection
etc, this counter and C901270012 will accumulate
simultaneously.
Measurement After BSC activates TCH/H (because allocation, usage are
Point signaling channel), receives correctly the CHL_ACK_ACK
message sent by BTS, or receives channel activation failure
message, wrong channel activation response message, timer
T9013 timeout, channel instance being released, channel being
forced to disconnection etc. (C901270011+C901270012). The
measurement points are C3, C4, as shown in Figure 16, Figure
17, Figure 18, and Figure 19.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 83


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901270011
Definition Number of signaling TCH/H allocation success due to handover
Description This counter counts the number of successful TCH/H channel
assignment in signaling channel handover.
After BSC responds channel request messages assignment and
successfully occupies channel, BSC sends channel activation
message CHL_ACT to BTS to activate the TCH/H. If activated
successfully, it will receive CHL_ACT_ACK message sent by BTS,
it indicates that TCH/H assigns successfully and the counter
accumulates.
Measurement BSC receives correctly CHL_ACT_ACK message sent by BTS and
Point the reason is that allocation and usage are signaling channel.
The measurement points are C3, D3, as shown in Figure 16,
Figure 17, Figure 18, and Figure 19.
Unit Times

C901270012
Definition Number of signaling TCH/H allocation failure due to handover
Description This counter counts the number of TCH/H channel assignment
failure.
After BSC responds channel request message assignment and
successfully occupies TCH/H channel, BSC send channel
activation message CHL_ACT to BTS to activate the TCH/H. If
channel activation fails due to receiving channel activation
failure message, wrong channel activation response message,
timer T9103 timeout, channel instance being released, channel
being forced to disconnection etc, this counter will increment.
Measurement BSC activates TCH/H to be used as signaling channel because of
Point handover, but receiving channel activation failure message,
wrong channel activation response message, timer T9103
timeout, channel instance being released, channel being forced
to disconnection etc. The measurement points are C3, D3, as
shown in Figure 32, Figure 33.

84 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

FIGURE 32 - INTERNAL H ANDOVER (INTERNAL TC INTRA-CELL HANDOVER)


FAILURE FLOW 1

FIGURE 33 - EXTERNAL H ANDOVER FAILURE FLOW 2 (INTERNAL TC)

MS BTS BSC MSC


HO_REQ
D1
Abis,TCU connect
CHL_ACT D2

CHL_ACT_NACK
... D3

Unit Times

C901270013
Definition Number of signaling TCH/H assignment attempts by BSC
Description This counter counts the number of attempt allocating TCH/H
channel to be signaling channel.
After BSC responds channel request message assignment and
successfully occupies channel, BSC sends channel activation
message CHL_ACT to BTS to activate the TCH/H. To immediate
allocation, after activated successfully BTS receives MS and send
EST_IND message to BSC, BSC receives the messages and this
counter accumulates; if it is impossible to receive the MS access
notification in the certain time, this allocation fails.
Measurement For immediate allocation, this counter counts the number when
Point BSC receives EST_IND message correctly or T31.3 timeout (not
receive the MS access notification in the certain time). The
measurement point is A3, as shown in Figure 13.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 85


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901270016
Definition Number of signaling TCH/H handover attempts
Description This counter counts the number of TCH/H channel attempt in
signaling channel handover, including the number of successful
TCH/H handover (C901270017), the number of TCH/H handover
failure with return (C901270018), and the number of TCH/H
handover failure without return (C901270019).
When BSC check the handover success message from MS in the
newly assigned TCH/H channel, this counter and C901270017
will accumulate; if receiving the failure message, this counter
and C901270018 will accumulate; if receiving abnormal
message, or instance being released, instance being forced to
disconnection, timer timeout, this counter and C901270019 will
accumulate.
For handover in cell, the symbol message of handover success is
ASS_COM. For handover between cells and outer handover, the
symbol message of handover success is HO_COM. For handover
in cell and between cells, the counter accumulates based on the
resource instance; for the outer handover, because the resource
instance is not in present BSC, the counter accumulates based
on the object instance.
Measurement On newly assigned TCH/H channel, BSC check the handover
Point success ASS_COM/HO_FAIL message sent by MS, or receives
handover failure ASS_FAIL/HO_FAIL message, receives
abnormal message, instance being released, instance being
forced to disconnection, timer timeout, this counter will
accumulate. The measurement points are C4, D4, as shown in
Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

C901270017
Definition Number of signaling TCH/H handover success
Description This counter counts the number of TCH/H channel success in
signaling channel handover.
When BSC check the handover success message sent by MS in
newly assigned TCH/H channel, this counter will accumulate.
For handover in cell, the symbol message of handover success is
ASS_COM. For handover between cells and outer handover, the
symbol message of handover success is HO_COM. For handover
in cell and between cells, the counter accumulates based on the
resource instance; for the outer handover, because the resource
instance is not in present BSC, the counter accumulates based
on the object instance.

86 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

Measurement BSC receives ASS_COM or HO_COM message. The measurement


Point points are C4, D4, as shown in Figure 16, Figure 17, Figure 18,
and Figure 19.
Unit Times

C901270018
Definition Number of signaling TCH/H handover failure
Description This counter counts the number of TCH/H channel return
handover failure.
This counter accumulates when MS on the TCH/H channel are in
handover, accesses new channel failure and returns original
channel, receives allocation failure on original channel or
handover failure.
Measurement BSC receives ASS_FAIL or HO_FAIL message. The measurement
Point points are C4, D4, as shown in Figure 20, Figure 21.
Unit Times

C901270019
Definition Number of signaling TCH/H handover failure messages do not
received by BSC
Description This counter counts the number of TCH/H channel return no
handover failure.
This counter accumulates when BSC sends allocation request to
MS or handover request, MS does not handover successfully and
does not return original channel.
Measurement BSC receives abnormal message, or instance being released,
Point instance being forced to disconnection, timer timeout message.
The measurement point is C4, as shown in Figure 22, Figure 23.
Unit Times

C901270021
Definition Number of voice TCH/H seizure success for assignment
Description This counter counts the number of TCH/H channel being
occupied successfully on allocation voice channel.
After BSC receives channel request message, it attempts to
assign channel for the request. This counter will accumulate if
assignment and occupation succeed. If application returns no
channel but possible to queue or force to disconnect, it enters

Confidential and Proprietary Information of ZTE CORPORATION 87


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

the state of waiting for resource. This counter accumulates if


waiting succeeds.
Measurement BSC applies for channel (because allocation, usage are voice
Point channel) and occupation succeeds or BSC receives inner waiting
resource valid message. The measurement point is B1, as shown
in Figure 20, Figure 21.
Unit Times

C901270024
Definition Number of voice TCH/H seizure success for handover
Description This counter counts the number of TCH/H channel being
occupied on voice channel handover.
After BSC receives channel request message, it attempts to
assign channel for the request. This counter will accumulate if
assignment and occupation succeed. If application returns no
channel but possible to queue or force to disconnect, it enters
the state of waiting for resource. This counter accumulates if
waiting succeeds.
Measurement BSC applies for channel (because handover, usage are voice
Point channel) and occupation succeeds or BSC receives inner waiting
resource valid message. The measurement points are C1, D1, as
shown in Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

C901270026
Definition Number of TCH/H allocation attempts for assignment by BSC
(speech version 1)
Description This counter counts the number of TCH/H channel being attempt
to assign on allocation voice channel (used for voice version 1),
including assignment success (C901270027) and assignment
failure (C900060175+C900060176+900060177+C900060178)
After BSC respond channel request message assignment and
successfully occupied TCH/H channel, BSC first finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate the the TCH/H. If activation succeeds, BSC will
receive the CHL_ACT_ACK message sent by BTS. It indicated
that assignment succeeds, this counter and C901270027
accumulate simultaneously; on the contrary, if failed, this
counter and another counter related the failure reason
accumulate siulataneously.
Measurement Assignment succeeds or fails (because allocation and usage are
Point voice channel, use voice version 1). The measurement points
are B2, B3, as shown in Figure 14, Figure 15.

88 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

Unit Times

C901270027
Definition Number of TCH/H allocation failure due to channel activation
failure for assignment (speech version 1)
Description This counter counts the number of TCH/H channel being attempt
to assign on allocation voice channel (used for voice version 1).
After BSC respond channel request message assignment and
successfully occupied channel, BSC sends channel activation
message CHL_ACT to BTS to activate the TCH/F. If activation
succeeds, BSC will receive the CHL_ACT_ACK message sent by
BTS. It indicated that TCH/H assignment succeeds, this counter
accumulate.
Measurement BSC correctly receives the CHL_ACT_ACK message sent by BTS,
Point and because allocation and usage are voice channel (use voice
version 1). The measurement point is B3, as shown in Figure 14,
Figure 15.
Unit Times

C901270032
Definition Number of TCH/H allocation attempts by BSC during handover
(speech version 1)
Description This counter counts the number of TCH/H channel being attempt
to assign on voice channel (use voice version 1) handover,
including assignment success (C901270033) and assignment
failure (C900060179+C900060180+900060181+C900060182)
After BSC respond channel request message assignment and
successfully occupied TCH/H channel, BSC first finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate the the TCH/H. If activation succeeds, BSC will
receive the CHL_ACT_ACK message sent by BTS. It indicated
that assignment succeeds, this counter and related C901270033
accumulate simultaneously; on the contrary, if failed, this
counter and another counter related the failure reason
accumulate simultaneously.
Measurement Assignment succeeds or fails (because handover, usage are
Point voice channel, use voice version 1). The measurement points
are C3, D3, as shown in Figure 16, Figure 17, and Figure 18.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 89


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901270033
Definition Number of TCH/H allocation success during handover (speech
version 1)
Description This counter counts the number of TCH/H channel success
assignment on voice channel (use voice version 1).
After BSC respond channel request message assignment and
successfully occupied channel, BSC sends channel activation
message CHL_ACT to BTS to activate the TCH/F. If activation
succeeds, it will receive CHL_ACT_ACK message sent by BTS. It
indicated that TCH/H assignment succeeds, this counter
accumulate.
Measurement BSC correctly receives the CHL_ACT_ACK message sent by BTS,
Point and because handover and usage are voice channel (use voice
version 1). The measurement points are C3, D3, as shown in
Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

C901270038
Definition Number of TCH/H allocation attempts by BSC for assignment
(speech version 2)
Description This counter counts the number of TCH/H channel being attempt
to assign on allocation voice channel (use voice version 2),
including assignment success (C901270039) and assignment
failure (C900060183+C900060184+900060185+C900060186)
After BSC respond channel request message assignment and
successfully occupied TCH/H channel, BSC first finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate the TCH/H. If activation succeeds, it will receive
the CHL_ACT_ACK message sent by BTS. It indicated that
TCH/H assignment succeeds, this counter and C901270039
accumulate simultaneously; on the contrary, if failed, this
counter and another counter related the failure reason
accumulate simultaneously.
Measurement Assignment succeeds or fails (because allocation, usage are
Point voice channel, use voice version 2). The measurement points
are B2, B3, as shown in Figure 14, Figure 15.
Unit Times

C901270039
Definition Number of TCH/H allocation success by BSC for assignment
(speech version 2)

90 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

Description This counter counts the number of TCH/H channel success


assignment on allocation voice channel (use voice version 2).
After BSC responds channel request message assignment and
successfully occupied channel, BSC sends channel activation
message CHL_ACT to BTS to activate the TCH/F. If activation
succeeds, it will receive CHL_ACT_ACK message sent by BTS. It
indicated that TCH/H assignment succeeds, this counter
accumulate.
Measurement BSC correctly receives the CHL_ACT_ACK message sent by BTS,
Point and because allocation and usage are voice channel (use voice
version 2). The measurement point is B3, as shown in Figure 14,
Figure 15.
Unit Times

C901270044
Definition Number of TCH/H allocation attempts for handover by BSC
(speech version 2)
Description This counter counts the number of TCH/H channel being attempt
to assign on voice channel (use voice version 2) handover,
including assignment success (C901270045) and assignment
failure (C900060187+C900060188+900060189+C900060190)
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, BSC first finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate the TCH/H. If activation succeeds, it will receive
the CHL_ACT_ACK message sent by BTS. It indicated that
TCH/H assignment succeeds, this counter and C901270045
accumulate simultaneously; on the contrary, if failed, this
counter and another counter related the failure reason
accumulate simultaneously.
Measurement Assignment succeeds or fails (because handover, usage are
Point voice channel, use voice version 2). The measurement points
are C2, D3, as shown in Figure 16, Figure 17, Figure 18, and
Figure 19.
Unit Times

C901270045
Definition Number of TCH/H allocation success for handover (speech
version 2)
Description This counter counts the number of TCH/H channel success
assignment on voice channel (use voice version 2).
After BSC responds channel request message assignment and
successfully occupied channel, BSC sends channel activation

Confidential and Proprietary Information of ZTE CORPORATION 91


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

message CHL_ACT to BTS to activate the TCH/F. If activation


succeeds, it will receive CHL_ACT_ACK message sent by BTS. It
indicated that TCH/H assignment succeeds, this counter
accumulate.
Measurement BSC correctly receives the CHL_ACT_ACK message sent by BTS,
Point and because handover and usage are voice channel (use voice
version 2). The measurement points are C3, D3, as shown in
Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

C901270050
Definition Number of TCH/H allocation attempts for assignment (speech
version 3)
Description This counter counts the number of TCH/H channel being attempt
to assign on allocation voice channel (use voice version 3),
including assignment success (C901270051) and assignment
failure (C900060191+C900060192+900060193+C900060194)
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, BSC first finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate the TCH/H. If activation succeeds, it will receive
the CHL_ACT_ACK message sent by BTS. It indicated that
TCH/H assignment succeeds, this counter and C901270045
accumulate simultaneously; on the contrary, if failed, this
counter and another counter related the failure reason
accumulate simultaneously.
Measurement Assignment succeeds or fails (because allocation, usage are
Point voice channel, use voice version 3). The measurement points
are B2, B3, as shown in Figure 14 and Figure 15.
Unit Times

C901270051
Definition Number of TCH/H allocation success for assignment (speech
version 3)
Description This counter counts the number of TCH/H channel success
assignment on allocation voice channel (use voice version 3).
After BSC responds channel request message assignment and
successfully occupied channel, BSC sends channel activation
message CHL_ACT to BTS to activate the TCH/F. If activation
succeeds, it will receive CHL_ACT_ACK message sent by BTS. It
indicated that TCH/H assignment succeeds, this counter
accumulate.

92 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

Measurement BSC correctly receives the CHL_ACT_ACK message sent by BTS,


Point and because allocation and usage are voice channel (use voice
version 3). The measurement point is B3, as shown in Figure 14
and Figure 15.
Unit Times

C901270056
Definition Number of TCH/H allocation attempts by BSC for handover
(speech version 3)
Description This counter counts the number of TCH/H channel being attempt
to assign on voice channel (use voice version 3), including
assignment success (C901270057) and assignment failure
(C900060195+C900060196+900060197+C900060198)
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, BSC first finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate the TCH/H. If activation succeeds, it will receive
the CHL_ACT_ACK message sent by BTS. It indicated that
TCH/H assignment succeeds, this counter and C901270057
accumulate simultaneously; on the contrary, if failed, this
counter and another counter related the failure reason
accumulate simultaneously.
Measurement Assignment succeeds or fails (because handover, usage are
Point voice channel, use voice version 3). The measurement points
are C3, D3, as shown in Figure 16, Figure 17, Figure 18, and
Figure 19.
Unit Times

C901270057
Definition Number of TCH/H allocation success for handover (speech
version 3)
Description This counter counts the number of TCH/H channel success
assignment on voice channel (use voice version 3).
After BSC responds channel request message assignment and
successfully occupied channel, BSC sends channel activation
message CHL_ACT to BTS to activate the TCH/H. If activation
succeeds, it will receive CHL_ACT_ACK message sent by BTS. It
indicated that TCH/H assignment succeeds, this counter
accumulate.
Measurement BSC correctly receives the CHL_ACT_ACK message sent by BTS,
Point and because handover and usage are voice channel (use voice
version 3). The measurement points are C3, D3, as shown in
Figure 16, Figure 17, Figure 18, and Figure 19.

Confidential and Proprietary Information of ZTE CORPORATION 93


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Unit Times

C901270062
Definition Number of Voice TCH/H assignment attempts by BSC
Description This counter counts the number of attempting TCH/H channel to
be voice channel, including assignment success (C900060199)
and allocation failure (C900060200).
After BSC responds channel request message assignment and
successfully occupied channel, BSC sends channel activation
message CHL_ACT to BTS to activate the TCH/H. For allocation
from A-interface, after receiving allocation success message, this
counter and C900060199 accumulate simultaneously. If it is
impossible to receive MS access notification in the certain time,
the assignment fails, this counter and C900060200 accumulate
simultaneously.
Measurement For allocation from A-interface, BSC correctly receives the
Point allocation success message, allocation failure message, timer
timeout message, or abnormal message, the instance being
released, the instance being forced to disconnection, this
counter accumulates. The measurement point is B5, as shown in
Figure 14 and Figure 15.
Unit Times

C901270065
Definition Number of Voice TCH/H handover attempts
Description This counter counts the number of TCH/H channel attempt in
voice channel handover, including the number of TCH/H
handover success (C900060201), TCH/H handover failure with
return (C901270067) and TCH/H handover failure without return
(C901270068).
During handover, when MS is accessed successfully on the new
channel, BSC will receive allocation finishing message ASS_COM
(handover in cell) or HO_COM message (handover between cells
and outer handover).
If BSC correctly receives the message above in the certain time,
it indicated that handover succeed, the related counter and
C900060201 will accumulate simultaneously; if BSC receives
HO_FAILURE, it returns handover failure, this counter and
C901270067 will accumulate simultaneously; if handover fails,
BSC does not receive HO_FAILURE, then no return handover
fails. This counter and C901270068 will accumulate
simultaneously.
For handover in cell and between cells, this counter accumulates
based on the resource instance; for outer handover, because the

94 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

resource instance is not in local BSC, the object instance


accumulates.
Measurement BSC receives ASS_COM/HO_COM message, ASS_FAIL/HO_FAIL
Point message or receive abnormal message, the instance being
released, the instance being forced to disconnection, timer
timeout. The measurement points are C4, D4, as shown in
Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

C901270067
Definition Number of Voice TCH/H handover failure
Description This counter counts the number of TCH/H channel returning
handover failure on voice channel handover.
MS is in handover on TCH/H channel, accesses new channel
failure and returns original channel. This counter accumulates
when receiving allocation failure/handover failure on original
channel.
Measurement BSC receives the ASS_FAIL/HO_FAIL message. The
Point measurement points are C4, D4, as shown in Figure 20 and
Figure 21.
Unit Times

C901270068
Definition Number of Voice TCH/H handover failure messages do not
received by BSC
Description This counter counts the number of TCH/H channel returning no
handover failure on voice channel handover.
BSC sends allocation request/handover request to MS, MS does
not handover successfully, not return resource channel, and
then accumulates.
Measurement BSC receives abnormal message, timer timeout message or the
Point instance being released, the instance being forced to
disconnection. The measurement points are C4, D4, as shown in
Figure 22 and Figure 23.
Unit Times

C901270070
Definition Number of data TCH/H seizure success for assignment
Description

Confidential and Proprietary Information of ZTE CORPORATION 95


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

This counter counts the number of TCH/H channel being


occupied successfully on allocation data channel.
After BSC receives channel request message, it attempts to
assign channel for the request. If assignments and occupation
succeed, this counter will accumulate; If application returns no
channel but possible to queue or force to disconnect, it enters
the status of waiting resource. This counter will also accumulate
until waiting succeeds.
Measurement BSC applies for channel (because allocation, usage are data
Point channels) and occupies successfully, or BSC receives inner
waiting resource valid message. The measurement points is B1,
as shown in Figure 14 and Figure 15.
Unit Times

C901270073
Definition Number of data TCH/H seizure success for handover
Description This counter counts the number of TCH/H channel being
occupied successfully on data channel handover.
After BSC receives channel request message, it attempts to
assign channel for the request. If assignments and occupation
succeed, this counter will accumulate; If application returns no
channel but possible to queue or force to disconnect, it enters
the status of waiting resource. This counter will also accumulate
until waiting succeeds.
Measurement BSC applies for channel (because handover, usage are data
Point channels) and occupies successfully, or BSC receives inner
waiting resource valid message. The measurement points are C1,
D1, as shown in Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

C901270075
Definition Number of data TCH/H allocation attempts for assignment by
BSC
Description This counter counts the number of TCH/H channel being
assigned on allocation data channel, including assignment
success (C901270076) and assignment failure (C900060202 +
C900060203 + C900060204 + C900060205).
Usage After BSC responds channel request message assignment and
successfully occupied TCH/H channel, BSC first finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate the TCH/H. If activation succeeds, it will receive
the CHL_ACT_ACK message sent by BTS. It indicated that
TCH/H assignment succeeds, this related counter and

96 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

C901270076 accumulate simultaneously; on the contrary, if fails,


this counter and another counter related the failure reason
accumulate simultaneously.
Measurement Assignment succeeds or fails (because allocation, usage are data
Point channel). The measurement points are B2, B5, as shown in
Figure 14 and Figure 15.
Unit Times

C901270076
Definition Number of data TCH/H allocation success for assignment
Description This counter counts the number of TCH/H channel being
assigned successfully.
After BSC responds channel request message assignment and
successfully occupied channel, BSC sends channel activation
message CHL_ACT to BTS to activate the TCH/H. If activation
succeeds, it will receive the CHL_ACT_ACK message sent by BTS.
It indicated that TCH/H assignment succeeds, This counter
accumulates.
Measurement BSC correctly receives the CHL_ACT_ACK message sent by BTS,
Point and because allocation and usage are data channel. The
measurement points is B3, as shown in Figure 14 and Figure 15.
Unit Times

C901270081
Definition Number of data TCH/H allocation attempts by BSC
Description This counter counts the number of TCH/H channel being
attempted to assign on data channel handover, including
assignment success (C901270082) and assignment failure
(C900060206 + C900060207 + C900060208 + C900060209).
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, BSC first finishes
connection, then sends channel activation message CHL_ACT to
BTS to activate the TCH/H. If activation succeeds, it will receive
the CHL_ACT_ACK message sent by BTS. It indicated that
TCH/H assignment succeeds, this related counter and
C901270082 accumulate simultaneously; on the contrary, if fails,
this counter and another counter related the failure reason
accumulate simultaneously.
Measurement Assignment succeeds or fails (because handover, usage are data
Point channels). The measurement points are C3, D3, as shown in
Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 97


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901270082
Definition Number of data TCH/H allocation success for handover
Description This counter counts the number of TCH/H channel assignment
successfully on data channel handover.
After BSC responds channel request message assignment and
successfully occupied channel, BSC sends channel activation
message CHL_ACT to BTS to activate the TCH/H. If activation
succeeds, it will receive the CHL_ACT_ACK message sent by BTS
and indicate that TCH/H assignment succeeds. This counter
accumulates.
Measurement BSC correctly receives the CHL_ACT_ACK message sent by BTS,
Point and because handover and usage are data channel. The
measurement points are C3, D3, as shown in Figure 16, Figure
17, Figure 18, and Figure 19.
Unit Times

C901270087
Definition Number of data TCH/H assignment attempts by BSC
Description This counter counts the number of attempting TCH/H channel to
be data channel, including assignment success (C900060210)
and allocation failure (C900060211).
After BSC responds channel request message assignment and
successfully occupied channel, BSC sends channel activation
message CHL_ACT to BTS to activate the TCH/H. For allocation
from A-interface, after receiving allocation success message, this
counter and C900060210 accumulate simultaneously. If it is
impossible to receive MS access notification in the certain time,
the assignment fails, this counter and C900060211 accumulate
simultaneously.
Measurement For allocation from A-interface, BSC correctly receives the
Point allocation success message, allocation failure message, timer
timeout message, or abnormal message, the instance being
released, the instance being forced to disconnect, this counter
accumulates. The measurement point is B5, as shown in Figure
14 and Figure 15.
Unit Times

C901270090
Definition Number of data TCH/H handover attempts
Description This counter counts the number of TCH/H channel attempt on
data channel handover, including TCH/H handover success

98 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

(C900060212), TCH/H returning handover failure (C901270092)


and TCH/H returning no handover failure (C901270093).
During handover, when MS is accessed successfully on the new
channel, BSC will receive allocation finishing message ASS_COM
(handover in cell) or HO_COM message (handover between cells
and outer handover).
If BSC correctly receives the message above in the certain time,
it indicated that handover succeed, this related counter and
C900060212 will accumulate simultaneously; if BSC receives
HO_FAILURE, it returns handover failure, this counter and
C901270092 will accumulate simultaneously; if handover fails,
BSC does not receive HO_FAILURE, then no returning handover
fails. This counter and C901270093 will accumulate
simultaneously.
For handover in cell and between cells, this counter accumulates
based on the resource instance; for outer handover, because the
resource instance is not in local BSC, the object instance
accumulates.
Measurement BSC receives ASS_COM/HO_COM message, ASS_FAIL/HO_FAIL
Point message or receive abnormal message, the instance being
released, the instance being forced to disconnection, timer
timeout. The measurement points are C4, D4, as shown in
Figure 16, Figure 17, Figure 18, and Figure 19.
Unit Times

C901270092
Definition Number of data TCH/H handover failure
Description This counter counts the number of TCH/H channel returning
handover failure on data channel handover.
MS is under handover on TCH/H channel, access new channel
fails then returns original channel. This counter accumulates
when receiving allocation failure/handover failure on original
channel.
Measurement BSC receives the ASS_FAIL/HO_FAIL message. The
Point measurement points are C4, D4, as shown in Figure 20 and
Figure 21.
Unit Times

C901270093
Definition Number of data TCH/H handover failure do not received by BSC
Description This counter counts the number of TCH/H channel returning no
handover failure on data channel handover.

Confidential and Proprietary Information of ZTE CORPORATION 99


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

After BSC sends allocation request/handover request to MS, MS


does not handover successfully, not go back to the original
channel, then accumulate.
Measurement BSC receives abnormal message, the instance being released,
Point the instance being forced to disconnect or timer timeout
message. The measurement point is C4, as shown in Figure 22
and Figure 23.
Unit Times

C901270094
Definition Number of TCH/H allocation failure for assignment due to TIPB
connection failure (Speech version 1)
Description This counter counts the number of TCH/H channel assignment
failure due to TIPB connection failure when allocating voice
channel (use voice version 1).
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, BSC sends TIU connection
request to TIPB. If TIU connection fails due to receiving TIU
connection failure, or wrong TIU connection respond message,
timer timeout, then this counter will accumulate.
Measurement Due to allocation BSC uses TCH/H. Receive connection failure
Point message, wrong connection respond message, or timer timeout
when in TIU connection. The measurement point is B2, as shown
in Figure 24.
Unit Times

C901270095
Definition Number of TCH/H allocation failure for assignment due to
Resource request to iTC failure (Speech version 1)
Description This counter counts the number of TCH/H channel assignment
failure due to iTC application resource failure when allocating
voice channel (use voice version 1).
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, BSC apply for resource to
iTC. If iTC application resource fails due to receiving iTC
resource unavailability, or wrong response message, or timer
timeout, then it contributes to TCH/H assignment failure and this
counter will accumulate.
Measurement Due to allocation BSC uses TCH/H. Receive iTC resource
Point unabailability, wrong respond message, or timer timeout when
in iTC application resource. The measurement point is B1, as
shown in Figure 25.
Unit Times

100 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

C901270096
Definition Number of TCH/H allocation failure for handover due to TIPB
connection failure (Speech version 1)
Description This counter counts the number of TCH/H channel assignment
failure due to TIU connection failure when in voice channel
handover (use voice version 1).
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, BSC sends TIU connection
request to TIPB. If TIU connection fails due to receiving TIU
connection failure, or wrong TIU connection response message,
timer timeout, then this counter will accumulate.
Measurement Due to handover BSC uses TCH/H. Receive connection failure
Point message, wrong connection response message, or timer timeout
when in TIU connection. The measurement points are C2, D2, as
shown in Figure 26 and Figure 27.
Unit Times

C901270097
Definition Number of TCH/H allocation failure for handover due to Resource
request to iTC failure (Speech version 1)
Description This counter counts the number of TCH/H channel assignment
failure due to iTC application resource failure when voice channel
handover (use voice version 1).
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, the type of BSC
judgement channel changes. Need to reapply TC resource, then
BSC apply for resource to iTC. If iTC application resource fails
due to receiving iTC resource unavailability, or wrong response
message, or timer timeout, then it contributes to TCH/H
assignment failure and this counter will accumulate.
Measurement Due to allocation BSC uses TCH/H. Receive iTC resource
Point unabailability, wrong response message, or timer timeout when
in iTC application resource. The measurement points are C1, D1,
as shown in Figure Figure 28 and Figure 29.
Unit Times

C901270098
Definition Number of TCH/H allocation failure for assignment due to TIPB
connection failure (Speech version 2)
Description

Confidential and Proprietary Information of ZTE CORPORATION 101


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

This counter counts the number of TCH/H channel assignment


failure due to TIPB connection failure when allocating voice
channel (use voice version 2).
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, BSC sends TIU connection
request to TIPB. If TIU connection fails due to receiving TIU
connection failure, or wrong TIU connection response message,
timer timeout, then this counter will accumulate.
Measurement Due to allocation BSC uses TCH/H. Receive connection failure
Point message, wrong connection response message, or timer timeout
when in TIU connection. The measurement point is B2, as shown
in Figure 24.
Unit Times

C901270099
Definition Number of TCH/H allocation failure for assignment due to
Resource request to iTC failure (Speech version 2)
Description This counter counts the number of TCH/H channel assignment
failure due to iTC application resource failure when allocating
voice channel (use voice version 2).
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, BSC apply for resource to
iTC. If iTC application resource fails due to receiving iTC
resource unavailability, or wrong response message, or timer
timeout, then it contributes to TCH/H assignment failure and this
counter will accumulate.
Measurement Due to allocation BSC uses TCH/H. Receive iTC resource
Point unabailability, wrong response message, or timer timeout when
in iTC application resource. The measurement point is B1, as
shown in Figure 25.
Unit Times

C901270100
Definition Number of TCH/H allocation failure for handover due to TIPB
connection failure (Speech version 2)
Description This counter counts the number of TCH/H channel assignment
failure due to TIU connection failure when voice channel
handover (use voice version 2).
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, BSC sends TIU connection
request to TIPB. If TIU connection fails due to receiving TIU
connection failure, or wrong TIU connection response message,
timer timeout, then this counter will accumulate.

102 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

Measurement Due to handover BSC uses TCH/H. Receive connection failure


Point message, wrong connection response message, or timer timeout
when in TIU connection. The measurement points are C2, D2, as
shown in Figure 26 and Figure 27.
Unit Times

C901270101
Definition Number of TCH/H allocation failure for handover due to Resource
request to iTC failure (Speech version 2)
Description This counter counts the number of TCH/H channel assignment
failure due to iTC application resource failure when voice channel
(use voice version 2).
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, the type of BSC
judgement channel changes. Need to reapply TC resource, then
BSC apply for resource to iTC. If iTC application resource fails
due to receiving iTC resource unavailability, or wrong response
message, or timer timeout, then it contributes to TCH/H
assignment failure and this counter will accumulate.
Measurement Due to handover BSC uses TCH/H. Receive iTC resource un
Point availability, wrong response message, or timer timeout when in
iTC application resource. The measurement points are C1, D1,
as shown in Figure 28 and Figure 29.
Unit Times

C901270102
Definition Number of TCH/H allocation failure for assignment due to TIPB
connection failure (Speech version 3)
Description This counter counts the number of TCH/H channel assignment
failure due to TIU connection failure when allocating voice
channel (use voice version 3).
After BSC responds channel request message assignment and
successfully occupied TCH/H channel, BSC sends TIU connection
request to TIPB. If TIU connection fails due to receiving TIU
connection failure, or wrong TIU connection response message,
timer timeout, then this counter will accumulate.
Measurement Due to allocation BSC uses TCH/H. Receive connection failure
Point message, wrong connection response message, or timer timeout
when in TIU connection. The measurement point is B2, as shown
in Figure 24.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 103


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901270103
Definition Number of TCH/H allocation failure for assignment due to
Resource request to iTC failure (Speech version 3)
Description This counter counts the number of TCH/H channel assignment
failure due to iTC application resource failure when allocating
voice channel (use voice version 3).
After BSC responds channel request message assignment and
successfully occupies TCH/H channel, BSC apply for resource to
iTC. If iTC application resource fails due to receiving iTC
resource unavailability, or wrong response message, or timer
timeout, then it contributes to TCH/H assignment failure and this
counter will accumulate.
Measurement Due to allocation BSC uses TCH/H. Receive iTC resource
Point unavailability, wrong response message, or timer timeout when
in iTC application resource. The measurement point is B1, as
shown in Figure 25.
Unit Times

C901270104
Definition Number of TCH/H allocation failure for handover due to TIPB
connection failure (Speech version 3)
Description This counter counts the number of TCH/H channel assignment
failure due to TIU connection failure when voice channel (use
voice version 3) handover.
After BSC responds channel request message assignment and
successfully occupies TCH/H channel, BSC sends TIU connection
request to TIPB. If TIU connection fails due to receiving TIU
connection failure, or wrong TIU connection response message,
timer timeout, then this counter will accumulate.
Measurement Due to handover BSC uses TCH/H. Receive connection failure
Point message, wrong connection response message, or timer timeout
when in TIU connection. The measurement points are C2, D2, as
shown in Figure 26 and Figure 27.
Unit Times

C901270105
Definition Number of TCH/H allocation failure for handover due to Resource
request to iTC failure (Speech version 3)

Description

104 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

This counter counts the number of TCH/H channel assignment


failure due to iTC application resource failure when voice channel
(use voice version 3) handover.
After BSC responds channel request message assignment and
successfully occupies TCH/H channel, BSC applies for resource to
iTC. If iTC application resource fails due to receiving iTC
resource unavailability, or wrong response message, or timer
timeout, then it contributes to TCH/H assignment failure and this
counter will accumulate.
Measurement Due to allocation BSC uses TCH/H. Receive iTC resource
Point unavailability, wrong response message, or timer timeout when
in iTC application resource. The measurement points are C1, D1,
as shown in Figure 28 and Figure 29.
Unit Times

C901270106
Definition Number of TCH/H allocation failure due to request AIPB resource
failure for assignment (speech version 1)
Description This counter counts the number of TCH/H allocation failure due
to request AIPB resource failure for assignment.
This counter increments while BSC receives assignment requests
(speech version 1) to apply for AIPB board resource from
database, failed request (including database return failure or no
AIPB board resource) indicates TCH/H allocation failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request AIPB resource failure for
assignment.
Measurement This counter increments while BSC correctly receives database
Point return failure or no AIPB board resource, and the reason to
apply for channel is assignment and purpose is voice channel.
The measurement point is A as shown in Figure 30.
Unit Times

C901270107
Definition Number of TCH/H allocation failure due to request UDP port
failure for assignment (speech version 1)
Description This counter counts the number of TCH/H channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(speech version 1), access request is sent to access module, if
access module returns access failure due to UDP port request
failure.

Confidential and Proprietary Information of ZTE CORPORATION 105


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Usage This counter is used to find out the frequency of TCH/H


allocation failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for
assignment. The measurement point is A as shown in Figure 31.
Unit Times

C901270108
Definition Number of TCH/H allocation failure due to AIPB connection
failure for assignment (speech version 1)
Description This counter counts the number of TCH/H channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(speech version 1), access request is sent to access module, if
access module returns access failure due to UDP port request
failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for assignment. The measurement point is A as shown
in Figure 31.
Unit Times

C901270109
Definition Number of TCH/H allocation failure due to request AIPB resource
failure for handover (speech version 1)
Description This counter counts the number of TCH/H allocation failure due
to request AIPB resource failure for assignment.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 1), the reason to request channel is handover, to
request AIPB resource from database. This counter increments if
failed to request AIPB (including database returning failure or no AIPB
resource), indicating TCH/H allocation failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request AIPB resource failure for
assignment.
Measurement This counter increments while BSC correctly receives database
Point return failure or no AIPB board resource, and the reason to
apply for channel is handover and purpose is voice channel. The
measurement point is A as shown in Figure 30.

106 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

Unit Times

C901270110
Definition Number of TCH/H allocation failure due to request UDP port
failure for handover (speech version 1)
Description This counter counts the number of TCH/H channel allocation
failure due to UDP port failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 1), the reason to request channel is handover, to
request access request for access module. This counter increments
while access module returns failure and the reason is failed to request
UDP port.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for handover.
The measurement point is A as shown in Figure 31.
Unit Times

C901270111
Definition Number of TCH/H allocation failure due to AIPB connection
failure for handover (speech version 1)
Description This counter counts the number of TCH/H channel allocation
failure due to AIPB access failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 1), the reason to request channel is handover, to
request access request for access module. This counter increments
while access module returns failure and the reason is failed to access
AIPB.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for handover. The measurement point is A as shown in
Figure 31.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 107


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901270112
Definition Number of TCH/H allocation failure due to request AIPB resource
failure for assignment (speech version 2)
Description This counter counts the number of TCH/H allocation failure due
to request AIPB resource failure for assignment.
This counter increments while BSC receives assignment requests
(speech version 2) to apply for AIPB board resource from
database, failed request (including database return failure or no
AIPB board resource) indicates TCH/H allocation failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request AIPB resource failure for
assignment.
Measurement This counter increments while BSC correctly receives database
Point return failure or no AIPB board resource, and the reason to
apply for channel is assignment and purpose is voice channel.
The measurement point is A as shown in Figure 30.
Unit Times

C901270113
Definition Number of TCH/H allocation failure due to request UDP port
failure for assignment (speech version 2)
Description This counter counts the number of TCH/H channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(speech version 2), access request is sent to access module, if
access module returns access failure due to UDP port request
failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for
assignment. The measurement point is A as shown in Figure 31.
Unit Times

C901270114
Definition Number of TCH/H allocation failure due to AIPB connection
failure for assignment (speech version 2)
Description This counter counts the number of TCH/H channel allocation
failure due to UDP port failure during assigning voice channel.

108 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

This counter increments while BSC receives assignment requests


(speech version 2), access request is sent to access module, if
access module returns access failure due to UDP port request
failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for assignment. The measurement point is A as shown
in Figure 31.
Unit Times

C901270115
Definition Number of TCH/H allocation failure due to request AIPB resource
failure for handover (speech version 2)
Description This counter counts the number of TCH/H allocation failure due
to request AIPB resource failure for assignment.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 2), the reason to request channel is handover, to
request AIPB resource from database. This counter increments if
failed to request AIPB (including database returning failure or no AIPB
resource), indicating TCH/H allocation failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request AIPB resource failure for
assignment.
Measurement This counter increments while BSC correctly receives database
Point return failure or no AIPB board resource, and the reason to
apply for channel is handover and purpose is voice channel. The
measurement point is A as shown in Figure 30.
Unit Times

C901270116
Definition Number of TCH/H allocation failure due to request UDP port
failure for handover (speech version 2)
Description This counter counts the number of TCH/H channel allocation
failure due to UDP port failure during handover.
This counter increments while BSC receives
EV_RANUMC_RADIO_APPLY message (speech version 2) to
request channel due to handover, access request is sent to
access module, if access module returns access failure due to
UDP port request failure.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 109


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

This counter is used to find out the frequency of TCH/H


allocation failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for handover.
The measurement point is A as shown in Figure 31.
Unit Times

C901270117
Definition Number of TCH/H allocation failure due to AIPB connection
failure for handover (speech version 2)
Description This counter counts the number of TCH/H channel allocation
failure due to AIPB access failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 2), the reason to request channel is handover, to
request access request for access module. This counter increments
while access module returns failure and the reason is failed to access
AIPB.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for handover. The measurement point is A as shown in
Figure 31.
Unit Times

C901270118
Definition Number of TCH/H allocation failure due to request AIPB resource
failure for assignment (speech version 3)
Description This counter counts the number of TCH/H allocation failure due
to request AIPB resource failure for assignment.
This counter increments while BSC receives assignment requests
(speech version 3) to apply for AIPB board resource from
database, failed request (including database return failure or no
AIPB board resource) indicates TCH/H allocation failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request AIPB resource failure for
assignment.
Measurement This counter increments while BSC correctly receives database
Point return failure or no AIPB board resource, and the reason to
apply for channel is assignment and purpose is voice channel.
The measurement point is A as shown in Figure 30.

110 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

Unit Times

C901270119
Definition Number of TCH/H allocation failure due to request UDP port
failure for assignment (speech version 3)
Description This counter counts the number of TCH/H channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(speech version 3), access request is sent to access module, if
access module returns access failure due to UDP port request
failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for
assignment. The measurement point is A as shown in Figure 31.
Unit Times

C901270120
Definition Number of TCH/H allocation failure due to AIPB connection
failure for assignment (speech version 3)
Description This counter counts the number of TCH/H channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(speech version 3), access request is sent to access module, if
access module returns access failure due to UDP port request
failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for assignment. The measurement point is A as shown
in Figure 31.
Unit Times

C901270121
Definition Number of TCH/H allocation failure due to request AIPB resource
failure for handover (speech version 3)

Confidential and Proprietary Information of ZTE CORPORATION 111


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Description This counter counts the number of TCH/H allocation failure due
to request AIPB resource failure for assignment.
This counter increments while BSC receives
EV_RANUMC_RADIO_APPLY message (speech version 3), the
reason to request channel is handover and request AIPB
resource from database, if request AIPB fails (including database
return failure or no AIPB resource), indicating TCH/H allocation
failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request AIPB resource failure for
assignment.
Measurement This counter increments while BSC correctly receives database
Point return failure or no AIPB board resource, and the reason to
apply for channel is handover and purpose is voice channel. The
measurement point is A as shown in Figure 30.
Unit Times

C901270122
Definition Number of TCH/H allocation failure due to request UDP port
failure for handover (speech version 3)
Description This counter counts the number of TCH/H channel allocation
failure due to UDP port failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 3), the reason to request channel is handover, to
request access request for access module. This counter increments
while access module returns failure and the reason is failed to request
UDP port.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for handover.
The measurement point is A as shown in Figure 31.
Unit Times

C901270123
Definition Number of TCH/H allocation failure due to AIPB connection
failure for handover (speech version 3)
Description This counter counts the number of TCH/H channel allocation
failure due to AIPB access failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (speech
version 3), the reason to request channel is handover, to
request access request for access module. This counter increments

112 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

while access module returns failure and the reason is failed to access
AIPB.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for handover. The measurement point is A as shown in
Figure 31.
Unit Times

C901270124
Definition Number of TCH/H allocation failure due to request AIPB resource
failure for assignment (data)
Description This counter counts the number of TCH/H allocation failure due
to request AIPB resource failure for assignment.
This counter increments while BSC receives assignment requests
(data) to apply for AIPB board resource from database, failed
request (including database return failure or no AIPB resource)
indicates TCH/H allocation failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request AIPB resource failure for
assignment.
Measurement This counter increments while BSC correctly receives database
Point return failure or no AIPB board resource, and the reason to
apply for channel is assignment and purpose is voice channel.
The measurement point is A as shown in Figure 30.
Unit Times

C901270125
Definition Number of TCH/H allocation failure due to request UDP port
failure for assignment (data)
Description This counter counts the number of TCH/H channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(data), access request is sent to access module, if access
module returns access failure due to UDP port request failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access

Confidential and Proprietary Information of ZTE CORPORATION 113


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

module, and the reason is request UDP port failure for


assignment. The measurement point is A as shown in Figure 31.
Unit Times

C901270126
Definition Number of TCH/H allocation failure due to AIPB connection
failure for assignment (data)
Description This counter counts the number of TCH/H channel allocation
failure due to UDP port failure during assigning voice channel.
This counter increments while BSC receives assignment requests
(data), access request is sent to access module, if access
module returns access failure due to UDP port request failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for assignment. The measurement point is A as shown
in Figure 31.
Unit Times

C901270127
Definition Number of TCH/H allocation failure due to request AIPB resource
failure for handover (data)
Description This counter counts the number of TCH/H allocation failure due
to request AIPB resource failure for assignment.
When BSC receives EV_RANUMC_RADIO_APPLY message (data),
the reason to request channel is handover, to request AIPB
resource from database. This counter increments if failed to
request AIPB (including database returning failure or no AIPB
resource), indicating TCH/H allocation failure.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request AIPB resource failure for
assignment.
Measurement This counter increments while BSC correctly receives database
Point return failure or no AIPB board resource, and the reason to
apply for channel is handover and purpose is voice channel. The
measurement point is A as shown in Figure 30.
Unit Times

114 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

C901270128
Definition Number of TCH/H allocation failure due to request UDP port
failure for handover (data)
Description This counter counts the number of TCH/H channel allocation
failure due to UDP port failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (data),
the reason to request channel is handover, to request access
request for access module. This counter increments while access
module returns failure and the reason is failed to request UDP port.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to request UDP port failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module, and the reason is request UDP port failure for handover.
The measurement point is A as shown in Figure 31.
Unit Times

C901270129
Definition Number of TCH/H allocation failure due to AIPB connection
failure for handover (data)
Description This counter counts the number of TCH/H channel allocation
failure due to AIPB access failure during handover.
When BSC receives EV_RANUMC_RADIO_APPLY message (data),
the reason to request channel is handover, to request access
request for access module. This counter increments while access
module returns failure and the reason is failed to access AIPB.
Usage This counter is used to find out the frequency of TCH/H
allocation failure due to AIPB access failure.
Measurement This counter increments while BSC correctly receives
Point EV_RANCONN_IPA_CONN_NACK message returned by access
module (the reason is AIPB access failure) or TwaitConn timer
timeout for handover. The measurement point is A as shown in
Figure 31.
Unit Times

C901270130
Definition Number of assign TCH/H release by forced handover to forced
handover source

Confidential and Proprietary Information of ZTE CORPORATION 115


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Description When the BSC CS service instance is forcibly handover, this


counter counts the number of times that the released TCH/H
resource is assigned to the forced handover source.
The BSC CS service instance is forcibly handover to release
resource, if the released TCH/H resource is assigned to the
forced handover source, the counter accumulates.
Usage This counter is used to find out the frequency of the TCH/H
released by forced handover being assigned to the forced
handover source.
Measurement The BSC CS service instance is forcibly handover to release
Point resource, if the released TCH/H resource is assigned to the
forced handover source, the counter accumulates.
Unit Times

C901270131
Definition Number of assign TCH/H release by forced handover to queuing
user
Description When the BSC CS service instance is forcibly handover, this
counter counts the number of times that the released TCH/H
resource is assigned to the queuing user.
The BSC CS service instance is forcibly handover to release
resource, if the released TCH/H resource is assigned to the
queuing user, the counter accumulates.
Usage This counter is used to find out the frequency of the TCH/H
released by forced handover being assigned to the queuing user.
Measurement The BSC CS service instance is forcibly handover to release
Point resource, if the released TCH/H resource is assigned to the
queuing user, the counter accumulates.
Unit Times

C901270132
Definition Number of restore TCH/H release by forced handover to DBS
Description When the BSC CS service instance is forcibly handover, this
counter counts the number of times that the released TCH/H
resource is restored to the database instead of being assigned to
other users.
The BSC CS service instance is forcibly handover to release
resource, if the released TCH/H resource is just released instead
of being assigned to other users, the counter accumulates.
Usage This counter is used to find out the frequency of the TCH/H
released by forced handover being restored to DBS.

116 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - TCH/H Measurement

Measurement The BSC CS service instance is forcibly handover to release


Point resource, if the released TCH/H resource is just released instead
of being assigned to other users, the counter accumulates.
Unit Times

C901270133
Definition Number of assign TCH/H release by forced release to forced
release source
Description When the BSC CS service instance is forcibly released, this
counter counts the number of times that the released TCH/H
resource is assigned to the forced release source.
The BSC CS service instance is forcibly released to release
resource, if the released TCH/H resource is assigned to the
forced release source, the counter accumulates.
Usage This counter is used to find out the frequency of the TCH/H
released by forced release being assigned to the forced release
source.
Measurement The BSC CS service instance is forcibly released to release
Point resource, if the released TCH/H resource is assigned to the
forced release source, the counter accumulates.
Unit Times

C901270134
Definition Number of assign TCH/H release by forced release to queuing
user
Description When the BSC CS service instance is forcibly released, this
counter counts the number of times that the released TCH/H
resource is assigned to the queuing user.
The BSC CS service instance is forcibly released to release
resource, if the released TCH/H resource is assigned to the
queuing user, the counter accumulates.
Usage This counter is used to find out the frequency of the TCH/H
released by forced release being assigned to the queuing user.
Measurement The BSC CS service instance is forcibly released to release
Point resource, if the released TCH/H resource is assigned to the
queuing user, the counter accumulates.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 117


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901270135
Definition Number of restore TCH/H release by forced release to DBS
Description When the BSC CS service instance is forcibly released, this
counter counts the number of times that the released TCH/H
resource is restored to the database instead of being assigned to
other users.
The BSC CS service instance is forcibly released to release
resource, if the released TCH/H resource is just released instead
of being assigned to other users, the counter accumulates.
Usage This counter is used to find out the frequency of the TCH/H
released by forced release being restored to DBS.
Measurement The BSC CS service instance is forcibly released to release
Point resource, if the released TCH/H resource is just released instead
of being assigned to other users, the counter accumulates.
Unit Times

118 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5

Abis Interface Message


Counter Measurement

This chapter contains detailed information about counters


related to Abis interface message counter measurement.

Overview
Abis interface message measurement is mainly for all kinds of
messages of Abis interface to count. It is convenient to find out
the frequency of all kinds of messages transmitting on Abis
interface. When BSC receives the messages sent by BTS, the
counter begin to count. The measurement point is A, as shown
in Figure 34.

FIGURE 34 - BTS SENDS MEASUREMENT POINT OF ABIS MESSAGE TO BSC

This counter accumulates before sending the message sent to


BTS by BSC. The measurement point is A, as shown in Figure 35.

FIGURE 35 – MEASUREMENT POINT WHEN BSC SENDS ABIS MESSAGE TO


BTS

Confidential and Proprietary Information of ZTE CORPORATION 119


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

The measurement takes cell as the statistics unit.

Abis Interface Message Counter


Index
Table 9 lists counters related to Abis interface message.

TABLE 9 - ABIS PORT MESSAGE COUNTING MEASUREMENT COUNTER

Counter ID What It Counts


C901280001 Number of DATA REQUEST messages
C901280002 Number of DATA INDICATION messages
C901280003 Number of ERROR INDICATION messages
C901280004 Number of ESTABLISH REQUEST messages
C901280005 Number of ESTABLISH CONFIRM messages
C901280006 Number of ESTABLISH INDICATION messages
C901280007 Number of RELEASE REQUEST messages
C901280008 Number of RELEASE CONFIRM messages
C901280009 Number of RELEASE INDICATION messages
C901280010 Number of UNIT DATA REQUEST messages
C901280011 Number of UNIT DATA INDICATION messages
C901280012 Number of CHANNEL ACTIVATION messages
C901280013 Number of CHANNEL ACTIVATION ACK messages
Number of CHANNEL ACTIVATION Negative ACK
C901280014
messages
Number of CONNECTION FAILURE INDICATION
C901280015
messages
C901280016 Number of DEACTIVATE SACCH messages
C901280017 Number of ENCRYPTION COMMAND messages
C901280018 Number of HANDOVER DETECTION messages
C901280019 Number of MEASUREMENT RESULT messages
C901280020 Number of MODE MODIFY REQUEST messages
Number of MODE MODIFY ACKNOWLEDGE
C901280021
messages
Number of MODE MODIFY NEGATIVE
C901280022
ACKNOWLEDGE messages
Number of PHYSICAL CONTEXT REQUEST
C901280023
messages
Number of PHYSICAL CONTEXT CONFIRM
C901280024
messages
C901280025 Number of RF CHANNEL RELEASE messages

120 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

Counter ID What It Counts


C901280026 Number of MS POWER CONTROL messages
C901280027 Number of BS POWER CONTROL messages
C901280028 Number of PREPROCESSED CONFIGURE messages
Number of PREPROCESSED MEASUREMENT RESULT
C901280029
messages
C901280030 Number of RF CHANNEL RELEASE ACK messages
C901280031 Number of SACCH INFO MODIFY messages
Number of
C901280032
ABIS_PREPROC_ENHANCEMEAS_RESULT messages
Number of ABIS_ROUND_TRIP_DELAY_REPORT
C901280033
messages
C901280034 Number of ABIS_PRE_HO_NOTIFY messages
C901280035 Number of ABIS_BCCH_INFO messages
C901280036 Number of ABIS_CCCH_LOAD_IND messages
C901280037 Number of ABIS_CHL_RQD messages
C901280038 Number of ABIS_DELETE_IND messages
C901280039 Number of ABIS_PAGING_CMD messages
C901280040 Number of ABIS_IMM_ASSIGN_CMD messages
C901280041 Number of ABIS_SMS_BROADCAST_REQ messages
C901280042 Number of ABIS_SMS_BROADCAST_CMD messages
C901280043 Number of ABIS_CBCH_LOAD_IND messages
C901280044 Number of ABIS_EGPRS_CHL_REQ messages
C901280045 Number of ABIS_LOAD_CONTROL messages
C901280046 Number of ABIS_END_LOAD_CONTROL messages
Number of ABIS_END_LOAD_CONTROL_ACK
C901280047
messages
C901280048 Number of ABIS_PCCCH_LOAD_IND messages
C901280049 Number of ABIS_RF_RESRC_IND messages
C901280050 Number of ABIS_SACCH_FILLING messages
C901280051 Number of ABIS_OVERLOAD messages
C901280052 Number of ABIS_ERROR_REPORT messages
C901280053 Number of ABIS_SYSINFO_REQ messages
C901280054 Number of ABIS_SI_BC_END messages
C901280055 Number of ABIS_SI_NACK messages
C901280056 Number of ABIS_PWRCTRL_IND messages
C901280057 Number of ABIS_SYSINFO_ACK messages
C901280061 Number of ABIS_PACKET_PBCCH_INF messages
C901280062 Number of ABIS_PACKET_CCCH_PARA messages

Confidential and Proprietary Information of ZTE CORPORATION 121


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Counter ID What It Counts


C901280063 Number of ABIS_PACKET_PBCCH_PARA messages
C901280064 Number of ABIS_PACKET_CHN_REQ messages
C901280065 Number of ABIS_PACKET_PAGING_CMD messages
Number of ABIS_PACKET_IMM_ASSIGN_CMD
C901280066
messages
Number of ABIS_PACKET_CONNECT_FAIL_IND
C901280067
messages
Number of ABIS_PACKET_PRACH_OVERLOAD
C901280068
messages
Number of ABIS_PACKET_PCH_OVERLOAD
C901280069
messages
C901280070 Number of ABIS_PACKET_TA_REQUEST messages
Number of ABIS_PACKET_TA_REQUEST_ACK
C901280071
messages
Number of ABIS_PACKET_CHN_CONFIG_CHG
C901280072
messages
Number of
C901280073
ABIS_PACKET_CHN_CONFIG_CHG_RESP messages
C901280074 Number of ABIS_PACKET_PIA_DEL_IND messages
Number of ABIS_PACKET_SEND_PIA_IND
C901280075
messages
Number of ABIS_PACKET_CHN_CONFIG_REQ
C901280076
messages
Number of ABIS_EGPRS_PACKET_CHN_REQ
C901280077
messages
C901280078 Number of ABIS_PS_CHANNEL_ACTIVE messages
Number of ABIS_PS_CHANNEL_ACTIVE_ACK
C901280079
messages
Number of ABIS_PS_CHANNEL_ACTIVE_NACK
C901280080
messages
C901280081 Number of ABIS_PS_CHANNEL_RELEASE messages
Number of ABIS_PS_CHANNEL_RELEASE_ACK
C901280082
messages
Number of ABIS_PS_CHANNEL_RELEASE_NACK
C901280083
messages
C901280084 Number of ABIS_PSCONN_CMM_REQ messages
C901280085 Number of ABIS_PSCONN_CMM_ACK messages
C901280086 Number of ABIS_PSCONN_CMM_NACK messages
C901280087 Number of ABIS_GLOBAL_RESET messages
C901280088 Number of ABIS_GLOBAL_RESET_ACK messages
C901280089 Number of ABIS_GLOBAL_RESET_NACK messages
C901280090 Number of ABIS_PACKET_UP_ASSIGN messages

122 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

Counter ID What It Counts


Number of ABIS_PACKET_DOWN_ASSIGN
C901280091
messages
C901280092 Number of ABIS_CSCONN_CMM_REQ messages
C901280093 Number of ABIS_CSCONN_CMM_ACK messages
C901280094 Number of ABIS_CSCONN_CMM_NACK messages
C901280095 Number of ABIS_CCMCONN_CMM_REQ messages
C901280096 Number of ABIS_CCMCONN_CMM_ACK messages
C901280097 Number of ABIS_CCMCONN_CMM_NACK messages
C901280098 Number ABIS_PACKET_ACCESS_REJ messages
Number of ABIS_PACKET_IMM_ASSIGN_CMD_NEW
C901280099
messages
C901280100 Number of PACKET_DOWNLINK_ASSIGN messages
C901280101 Number of PACKET_UPLINK_ASSIGN messages
Number of ABIS_PACKET_ACCESS_REJ_NEW
C901280102
messages

C901280001
Definition Number of DATA REQUEST messages
Description This counter counts the number of data request messages to be
confirmed sent by BSC to LAPD.
Usage This counter is used to find out the frequency of data request
message to be confirmed transmitting on Abis interface.
Measurement This counter increments when BSC sends DATA REQuest
Point message to BTS. The measurement point is A, as shown in
Figure 35.
Unit Times

C901280002
Definition Number of DATA INDICATION messages
Description This counter counts the number of data indication messages
received by BSC on Abis interface.
Usage This counter is used to find out the frequency of data indication
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives DATA INDication
Point message. The measurement point is A, as shown in Figure 34.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 123


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901280003
Definition Number of ERROR INDICATION messages
Description When radio channel generates errors (for example radio link
fault), BTS sends ERROR INDication message to notify BSC. This
counter counts the number of ERROR INDication messages of
Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of error indication
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives ERROR INDication
Point message. The measurement point is A, as shown in Figure 34.
Unit Times

C901280004
Definition Number of ESTABLISH REQUEST messages
Description When BSC delivers short messages need received by A-interface
to MS, it will send Establish Request messages to establish
process. This counter counts the number of Establish Request
messages sent by BSC to BTS.
Usage This counter is used to find out the frequency of Establish
Request messages transmitting on Abis interface.
Measurement This counter increments when BSC sends Establish Request
Point message to BTS. The measurement point is A, as shown in
Figure 35.
Unit Times

C901280005
Definition Number of ESTABLISH CONFIRM messages
Description When BSC receives Establish Confirm messages, it indicates that
establishing link succeeds. BSC can deliver short messages to
MS. This counter counts the number of Establish Confirm
messages of Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of Establish
Confirm messages transmitting on Abis interface.
Measurement This counter increments when BSC receives Establish Confirm
Point message. The measurement point is A, as shown in Figure 34.
Unit Times

124 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

C901280006
Definition Number of ESTABLISH INDICATION messages
Description When MS receives assignment command (including immediate
assignment) of BSC or handover command, it sends SABM frame
to network, BTS will send Establish Indication messages to BSC
after receiving. This counter counts the number of Establish
Indication messages of Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of Establish
Indication messages transmitting on Abis interface.
Measurement This counter increments when BSC receives Establish Indication
Point message. The measurement point is A, as shown in Figure 34.
Unit Times

C901280007
Definition Number of RELEASE REQUEST messages
Description When BSC releases one channel due to other reasons, it will
send Release Request messages to initiate channel release flow.
This counter counts the number of Release Request messages
sent by BSC to BTS.
Usage This counter is used to find out the frequency of Release Request
messages transmitting on Abis interface.
Measurement This counter increments when BSC sends Release Request
Point message to BTS. The measurement point is A, as shown in
Figure 35.
Unit Times

C901280008
Definition Number of RELEASE CONFIRM messages
Description When BSC sends Release Confirm messages, MS releases
channel, BTS sends BSC Release Confirm messages as reply.
This counter counts the number of Release Confirm messages of
Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of Release Confirm
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives Release Confirm
Point messages. The measurement point is A, as shown in Figure 34.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 125


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901280009
Definition Number of RELEASE INDICATION messages
Description When BTS receives one DISC frame sent by MS through one link
layer of multi-frame layer, BTS sends one Release Indication
message to notify that link layer connection of BSC radio
interface is released. This counter counts the number of Release
Indication messages of Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of Release
Indication messages transmitting on Abis interface.
Measurement This counter increments when BSC receives Release Indication
Point messages. The measurement point is A, as shown in Figure 34.
Unit Times

C901280010
Definition Number of UNIT DATA REQUEST messages
Description BTS sends a UNIT DATA REQUEST message to BTS. The
message includes complete L3 message needed to send in
uncertain mode. This counter counts the number of UNIT DATA
REQUEST messages sent by BSC to BTS.
Usage This counter is used to find out the frequency of UNIT DATA
REQUEST messages transmitting on Abis interface.
Measurement This counter increments when BSC sends UNIT DATA REQUEST
Point messages to BTS. The measurement point is A, as shown in
Figure 35.
Unit Times

C901280011
Definition Number of UNIT DATA INDICATION messages
Description BTS sends a UNIT DATA INDICATION message to BTS. The
message includes complete L3 message needed to send in
uncertain mode. This counter counts the number of UNIT DATA
INDICATION messages received by BSC.
Usage This counter is used to find out the frequency of UNIT DATA
INDICATION messages transmitting on Abis interface.
Measurement This counter increments when BSC receives UNIT DATA
Point INDICATION messages. The measurement point is A, as shown
in Figure 34.
Unit Times

126 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

C901280012
Definition Number of CHANNEL ACTIVATION messages
Description When BSC want to activate one channel due to other reasons, it
sends CHANNEL ACTIVATION message to BTS to initiate channel
activation flow. This counter counts the number of CHANNEL
ACTIVATION messages sent by BSC to BTS.
Usage This counter is used to find out the frequency of CHANNEL
ACTIVATION messages transmitting on Abis interface.
Measurement This counter increments when BSC sends CHANNEL ACTIVATION
Point messages. The measurement point is A, as shown in Figure 35.
Unit Times

C901280013
Definition Number of CHANNEL ACTIVATION ACK messages
Description After BSC finishes activating channel, it sends CHANNEL
ACTIVATION ACK message to BSC as the response of channel
activation message. This counter counts the number of
CHANNEL ACTIVATION ACK messages of Abis interface
messages received by BSC.
Usage This counter is used to find out the frequency of CHANNEL
ACTIVATION ACK messages transmitting on Abis interface.
Measurement This counter increments when BSC receives CHANNEL
Point ACTIVATION ACK messages. The measurement point is A, as
shown in Figure 34.
Unit Times

C901280014
Definition Number of CHANNEL ACTIVATION Negative ACK messages
Description After BSC receives channel activation command, if it is
impossible to finish channel activation due to other reasons (for
example TRX fault etc.), it sends CHANNEL ACTIVATION
Negative ACK message to BSC to notify that BSC channel
activation fail. This counter counts the number of CHANNEL
ACTIVATION Negative ACK messages of Abis interface messages
received by BSC.
Usage This counter is used to find out the frequency of CHANNEL
ACTIVATION Negative ACK messages transmitting on Abis
interface.

Confidential and Proprietary Information of ZTE CORPORATION 127


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Measurement This counter increments when BSC receives CHANNEL


Point ACTIVATION Negative ACK messages. The measurement point is
A, as shown in Figure 34.
Unit Times

C901280015
Definition Number of CONNECTION FAILURE INDICATION messages
Description When connection fails due to certain reason (for example TRX
fault), BTS sends CONNECTION FAILURE INDICATION message
to notify BSC. This counter counts the number of CONNECTION
FAILURE INDICATION messages of Abis interface messages
received by BSC.
Usage This counter is used to find out the frequency of CONNECTION
FAILURE INDICATION messages transmitting on Abis interface.
Measurement This counter increments when BSC receives CONNECTION
Point FAILURE INDICATION messages. The measurement point is A,
as shown in Figure 34.
Unit Times

C901280016
Definition Number of DEACTIVATE SACCH messages
Description When BSC activate SACCH due to certain reason (releasing radio
channel), it sends DEACTIVATE SACCH message to initiate to
activate flow. This counter counts the number of DEACTIVATE
SACCH messages sent by BSC to LAPD.
Usage This counter is used to find out the frequency of DEACTIVATE
SACCH messages transmitting on Abis interface.
Measurement This counter increments when BSC receives DEACTIVATE SACCH
Point messages. The measurement point is A, as shown in Figure 35.
Unit Times

C901280017
Definition Number of ENCRYPTION COMMAND messages
Description BSC initiate ENCRYPTION COMMAND message to require
encryption. This counter counts the number of ENCRYPTION
COMMAND messages sent by BSC to LAPD.
Usage This counter is used to find out the frequency of ENCRYPTION
COMMAND messages transmitting on Abis interface.

128 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

Measurement This counter increments when BSC sends ENCRYPTION


Point COMMAND messages to BTS. The measurement point is A, as
shown in Figure 35.
Unit Times

C901280018
Definition Number of HANDOVER DETECTION messages
Description During the outer incoming handover process controlled by MSC,
after MS receives handover command, then sends SABM frame
to BTS to initiate incoming handover. After receiving BTS sends
HANDOVER DETCTION messages to notify BSC. This counter
counts the number of HANDOVER DETCTION messages of Abis
interface messages received by BSC.
Usage This counter is used to find out the frequency of HANDOVER
DETCTION messages transmitting on Abis interface.
Measurement This counter increments when BSC receives HANDOVER
Point DETCTION messages. The measurement point is A, as shown in
Figure 34.
Unit Times

C901280019
Definition Number of MEASUREMENT RESULT messages
Description In general, MS reports a measurement report ( Um interface
message MEASUREMENT messages) to BTS per 102/104 multi-
frame through SACCH channel, including DL measurement
information from 102/104 multi-frame. During the period BTS
are also under DL measurement. Therefore every 102/104
multi-frame, BTS will combine these two information together,
send to BSC through Abis message MEASUREMENT RESULT.
For some reasons, BTS does not receive the MS measurement
report on time, only put its UL measurement results into this
MEASUREMENT RESULTS messages to send to BSC. This counter
counts the number of MEASUREMENT RESULTS messages of
Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of MEASUREMENT
RESULTS messages transmitting on Abis interface.
Measurement This counter increments when BSC receives MEASUREMENT
Point RESULTS messages. The measurement point is A, as shown in
Figure 34.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 129


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901280020
Definition Number of MODE MODIFY REQUEST messages
Description During the allocation or inner handover process, when the
channel type of allocation and current type are in agreement but
the channel modes are different, BSC sends MODE MODIFY
REQUEST messages to BTS to notify to change channel mode.
This counter counts the number of MODE MODIFY REQUEST
messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of MODE MODIFY
REQUEST messages transmitting on Abis interface.
Measurement This counter increments when BSC sends MODE MODIFY
Point REQUEST messages to BTS. The measurement point is A, as
shown in Figure 35.
Unit Times

C901280021
Definition Number of MODE MODIFY ACKNOWLDGE messages
Description After BTS receives MODE MODIFY ACKNOWLEDGE messages,
finish channel mode change. Then BTS sends MODE MODIFY
ACKNOWLEDGE messages to BSC as reply. This counter counts
the number of MODE MODIFY ACKNOWLEDGE messages of Abis
interface messages received by BSC.
Usage This counter is used to find out the frequency of MODE MODIFY
ACKNOWLEDGE messages transmitting on Abis interface.
Measurement This counter increments when BSC receives MODE MODIFY
Point ACKNOWLEDGE messages. The measurement point is A, as
shown in Figure 34.
Unit Times

C901280022
Definition Number of MODE MODIFY NEGATIVE ACKNOWLDGE messages
Description After BTS receives MODE MODIFY REQUEST messages, it is
impossible to finish channel mode change due to certain reason,
it will send MODE MODIFY NEGATIVE ACKNOWLEDGE messages
to BSC as reply. This counter counts the number of MODE
MODIFY NEGATIVE ACKNOWLEDGE messages of Abis interface
messages received by BSC.
Usage This counter is used to find out the frequency of MODE MODIFY
NEGATIVE ACKNOWLEDGE messages transmitting on Abis
interface.

130 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

Measurement This counter increments when BSC receives MODE MODIFY


Point NEGATIVE ACKNOWLEDGE messages. The measurement point is
A, as shown in Figure 34.
Unit Times

C901280023
Definition Number of PHYSICAL CONTEXT REQUEST messages
Description When BSC needs to know the current channel of MS (physical
context), it sends PHYSICAL CONTEXT REQUEST messages to
BTS to apply. This counter counts the number of PHYSICAL
CONTEXT REQUEST messages of Abis interface messages sent
by BSC.
Usage This counter is used to find out the frequency of PHYSICAL
CONTEXT REQUEST messages transmitting on Abis interface.
Measurement This counter increments when BSC sends PHYSICAL CONTEXT
Point REQUEST messages to BTS. The measurement point is A, as
shown in Figure 35.
Unit Times

C901280024
Definition Number of PHYSICAL CONTEXT CONFIRM messages
Description After BTS receives PHYSICAL CONTEXT REQUEST messages,
report to BSC about related physical context through PHYSICAL
CONTEXT COMFIRM messages. This counter counts the number
of PHYSICAL CONTEXT COMFIRM messages of Abis interface
messages received by BSC.
Usage This counter is used to find out the frequency of PHYSICAL
CONTEXT COMFIRM messages transmitting on Abis interface.
Measurement This counter increments when BSC receives PHYSICAL CONTEXT
Point COMFIRM messages to BTS. The measurement point is A, as
shown in Figure 34.
Unit Times

C901280025
Definition Number of RF CHANNEL RELEASE messages
Description When the certain logical channel is not used, BSC needs to
notify BTS to release the channel. Therefore it sends RF
CHANNEL RELEASE messages to BTS. This counter counts the
number of RF CHANNEL RELEASE messages of Abis interface
messages received by BSC.

Confidential and Proprietary Information of ZTE CORPORATION 131


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Usage This counter is used to find out the frequency of RF CHANNEL


RELEASE messages transmitting on Abis interface.
Measurement This counter increments when BSC sends RF CHANNEL RELEASE
Point messages to BTS. The measurement point is A, as shown in
Figure 35.
Unit Times

C901280026
Definition Number of MS POWER CONTROL messages
Description BSC can calculate the proper transmitting power used by MS
according to measurement data result. Therefore it notify control
parameters to BTS through MS POWER CONTROL messages.
BTS sends the information to MS through L1 frame header of
SACCH, then finish MS POWER CONTROL ultimately. This
counter counts the number of MS POWER CONTROL messages of
Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of MS POWER
CONTROL messages transmitting on Abis interface.
Measurement This counter increments when BSC sends MS POWER CONTROL
Point messages to BTS. The measurement point is A, as shown in
Figure 35.
Unit Times

C901280027
Definition Number of BS POWER CONTROL messages
Description BSC can calculate the proper transmitting power used by BTS
side according to measurement data result. Therefore it notifies
control parameters to BTS through BS POWER CONTROL
messages. BTS conducts the corresponding transmission power
adjustment work immediately. This counter counts the number
of BS POWER CONTROL messages of Abis interface messages
sent by BSC.
Usage This counter is used to find out the frequency of BS POWER
CONTROL messages transmitting on Abis interface.
Measurement This counter increments when BSC sends BS POWER CONTROL
Point messages to BTS. The measurement point is A, as shown in
Figure 35.
Unit Times

132 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

C901280028
Definition Number of PREPROCESSED CONFIGURE messages
Description In order to reduce the load of processed measurement report of
BSC and the messages flux of Abis interface, the process of
preprocessed measurement report can be used. First BTS
processes the 102/104 multi-frame measurement data
(average), then sends the processed result to BSC at lower
frequency.
To make BTS conduct preprocessed measurement report, first
BSC sends PREPROCESSED CONFIGURE messages to BTS. The
message includes some basic control parameters being
processed. This counter counts the number of PREPROCESSED
CONFIGURE messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of PREPROCESSED
CONFIGURE messages transmitting on Abis interface.
Measurement This counter increments when BSC sends PREPROCESSED
Point CONFIGURE messages to BTS. The measurement point is A, as
shown in Figure 35.
Unit Times

C901280029
Definition Number of PREPROCESSED MEASUREMENT RESULT messages
Description After BTS receives PREPROCESSED CONFIGURE messages, it
begins to preprocess the measurement report, sends the
preprocessed result to BSC through PREPROCESSED
MEASUREMENT RESULT messages. This counter counts the
number of PREPROCESSED MEASUREMENT RESULT messages of
Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of PREPROCESSED
MEASUREMENT RESULT messages transmitting on Abis interface.
Measurement This counter increments when BSC receives PREPROCESSED
Point MEASUREMENT RESULT messages to BTS. The measurement
point is A, as shown in Figure 34.
Unit Times

C901280030
Definition Number of RF CHANNEL RELEASE ACK messages
Description After BTS receives RF CHANNEL RELEASE messages and
releases this channel, returns one RF CHANNEL RELEASE ACK
messages to BSC. This counter counts the number of RF

Confidential and Proprietary Information of ZTE CORPORATION 133


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

CHANNEL RELEASE ACK messages of Abis interface messages


received by BSC.
Usage This counter is used to find out the frequency of RF CHANNEL
RELEASE ACK messages transmitting on Abis interface.
Measurement This counter increments when BSC receives RF CHANNEL
Point RELEASE ACK messages to BTS. The measurement point is A, as
shown in Figure 34.
Unit Times

C901280031
Definition Number of SACCH INFO MODIFY messages
Description On the DL direction of SACCH, BTS will send RR message
SI5/5bis/5ter/6 of Um interface to MS repeatedly, besides
informing power control parameters and the latest time advance
of L1 frame header to MS.
When BSC want to modify related message on one SACCH, send
one SACCH INFO MODIFY messages to BTS. The message
includes RR message SI5/5bis/5ter/6 of new Um interface. This
counter counts the number of SACCH INFO MODIFY messages of
Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of SACCH INFO
MODIFY messages transmitting on Abis interface.
Measurement This counter increments when BSC sends SACCH INFO MODIFY
Point messages to BTS. The measurement point is A, as shown in
Figure 35.
Unit Times

C901280032
Definition Number of ABIS_PREPROC_ENHANCEMEAS_RESULT messages
Description This counter counts the number of
ABIS_PREPROC_ENHANCEMEAS_RESULT messages received by
BSC.
Usage This counter is used to find out the frequency of enhanced
preprocessed measurement report message transmitting on Abis
interface.
Measurement This counter increments when BSC receives
Point ABIS_PREPROC_ENHANCEMEAS_RESULT messages. The
measurement point is A, as shown in Figure 34.
Unit Times

134 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

C901280033
Definition Number of ABIS_ROUND_TRIP_DELAY_REPORT messages
Description This counter counts the number of
ABIS_ROUND_TRIP_DELAY_REPORT messages received by BSC.
Usage This counter is used to find out the frequency of ROUND TRIP
DELAY REPORT messages transmitting on Abis interface.
Measurement This counter increments when BSC receives ROUND TRIP DELAY
Point REPORT messages. The measurement point is A, as shown in
Figure 34.
Unit Times

C901280034
Definition Number of ABIS_PRE_HO_NOTIFY messages
Description This counter counts the number of ABIS_PRE_HO_NOTIFY
messages received by BSC.
Usage This counter is used to find out the frequency of
PRE_HO_NOTIFY messages transmitting on Abis interface.
Measurement This counter increments when BSC sends PRE-HANDOVER
Point NOFICATION messages. The measurement point is A, as shown
in Figure 35.
Unit Times

C901280035
Definition Number of ABIS_BCCH_INFO messages
Description When BSC want to messages sent on BCCH, it sends one BCCH
INFORMATION messages to BTS. The message includes
complete SI messages of RR lay of Um interface needed to be
modified. This counter counts the number of ABIS_BCCH_INFO
messages sent by BSC.
Usage This counter is used to find out the frequency of BCCH changing
messages transmitting on Abis interface.
Measurement This counter increments when BSC sends BCCH INFOMATION
Point messages. The measurement point is A, as shown in Figure 35.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 135


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901280036
Definition Number of ABIS_CCCH_LOAD_IND messages
Description When BSC checks one CCCH overload, it needs to send one
CCCH LOAD INDICATION message to BSC periodically to notify
BSC. This counter counts the number of ABIS_CCCH_LOAD_IND
messages received by BSC.
Usage This counter is used to find out the frequency of CCCH load
indication messages transmitting on Abis interface.
Measurement This counter increments when BSC receives CCCH LOAD
Point INDICATION messages. The measurement point is A, as shown
in Figure 34.
Unit Times

C901280037
Definition Number of ABIS_CHL_RQD messages
Description When BTS checks one random access of MS on RACH (CHANNEL
REQUEST of MS), it sends one CHANNEL REQUIRED message to
BSC, including valid messages of CHANNEL REQUEST. This
counter counts the number of ABIS_CHL_RDQ messages
received by BSC.
Usage This counter is used to find out the frequency of MS channel
request messages transmitting on Abis interface.
Measurement This counter increments when BSC receives CHANNEL
Point REQUIRED messages. The measurement point is A, as shown in
Figure 34.
Unit Times

C901280038
Definition Number of ABIS_DELETE_IND messages
Description When BTS finds to delete one IMMEDIATE ASSIGN COMMAND
message due to DL congestion, it sends one DELETE
INDICATION message to notify BSC. This counter counts the
number of ABIS_DELETE_IND messages received by BSC.
Usage This counter is used to find out the frequency of DELETE
INDICATION messages transmitting on Abis interface.
Measurement This counter increments when BSC receives DELETE
Point INDICATION messages. The measurement point is A, as shown
in Figure 34.
Unit Times

136 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

C901280039
Definition Number of ABIS_PAGING_CMD messages
Description When BSC receives PADING message of BSSMAP protocol sent
by MSC from A-interface, it sends one PAGING COMMAND
message to BTS, including MS identity (TMSI or IMSI). BTS
sends to MS on PCH of radio interface through PAGING REQUEST.
This counter counts the number of ABIS_PAGING_CMD
messages sent by BSC.
Usage This counter is used to find out the frequency of PAGING
COMMAND messages transmitting on Abis interface.
Measurement This counter increments when BSC sends PAGING COMMAND
Point messages to BTS. The measurement point is A, as shown in
Figure 35.
Unit Times

C901280040
Definition Number of ABIS_IMM_ASSIGN_CMD messages
Description After BSC receives MS channel request, it tries for assigning one
channel accordingly and activates the channel, then sends one
IMMEDIATE ASSIGN COMMAND message to BTS.
This message includes one complete Um interface RR layer
IMMEDIATE ASSIGNMENT or IMMEDIATE ASSIGNMENT
EXTENDED or IMMEDIATE ASSIGNMENT REJECT (if there is no
channel) to notify MS.
After BTS receives this message, it is in charge of assigning Um
interface RR layer message of the message on CCCH to MS. This
counter counts the number of ABIS_IMM_ASSIGN_CMD
messages sent by BSC.
Usage This counter is used to find out the frequency of IMMEDIATE
ASSIGN COMMAND messages transmitting on Abis interface.
Measurement This counter increments when BSC sends IMMEDIATE ASSIGN
Point COMMAND messages to BTS. The measurement point is A, as
shown in Figure 35.
Unit Times

C901280041
Definition Number of ABIS_SMS_BROADCAST_REQ messages
Description This counter counts the number of ABIS_SMS_BROADCAST_REQ
messages sent by BSC.

Confidential and Proprietary Information of ZTE CORPORATION 137


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Usage This counter is used to find out the frequency of SMS


BROADCAST REQUEST messages transmitting on Abis interface.
Measurement This counter increments when BSC sends SMS BROADCAST
Point REQUEST messages to BTS. The measurement point is A, as
shown in Figure 35.
Unit Times

C901280042
Definition Number of ABIS_SMS_BROADCAST_CMD messages
Description This counter counts the number of
ABIS_SMS_BROADCAST_CMD messages sent by BSC.
Usage This counter is used to find out the frequency of SMS
BROADCAST COMMAND messages transmitting on Abis interface.
Measurement This counter increments when BSC sends MS BROADCAST
Point COMMAND messages to BTS. The measurement point is A, as
shown in Figure 35.
Unit Times

C901280043
Definition Number of ABIS_CBCH_LOAD_IND messages
Description When BTS checks CBCH over load or less than load, it sends
CBCH LOAD INDICATION message to notify BSC. This counter
counts the number of ABIS_CBCH_LOAD_IND messages sent by
BSC.
Usage This counter is used to find out the frequency of CBCH LOAD
INDICATION messages transmitting on Abis interface.
Measurement This counter increments when BSC receives CBCH LOAD
Point INDICATION messages to BTS. The measurement point is A, as
shown in Figure 34.
Unit Times

C901280044
Definition Number of ABIS_EGPRS_CHL_REQ messages
Description This counter counts the number of ABIS_EGPRS_CHL_REQ
messages sent by BSC.
Usage This counter is used to find out the frequency of
EGPRS_CHL_REQ messages transmitting on Abis interface.

138 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

Measurement This counter increments when BSC receives


Point ABIS_EGPRS_CHL_REQ messages. The measurement point is A,
as shown in Figure 34.
Unit Times

C901280045
Definition Number of ABIS_LOAD_CONTROL messages
Description When BTS checks one CCCH overload, it needs to send
CCCHLOAD INDICATION message periodically to inform BSC.
This counter counts the number of ABIS_LOAD_CONTROL
messages receives by BSC.
Usage This counter is used to find out the frequency of CCCHLOAD
INDICATION messages transmitting on Abis interface.
Measurement This counter increments when BSC receives CCCHLOAD
Point INDICATION messages. The measurement point is A, as shown
in Figure 34.
Unit Times

C901280046
Definition Number of ABIS_END_LOAD_CONTROL messages
Description This counter counts the number of ABIS_END_LOAD_CONTROL
messages sent by BSC.
Usage This counter is used to find out the frequency of END LOAD
CONTROL messages transmitting on Abis interface.
Measurement This counter increments when BSC sends
Point ABIS_END_LOAD_CONTROL messages to BTS. The
measurement point is A, as shown in Figure 35.
Unit Times

C901280047
Definition Number of ABIS_END_LOAD_CONTROL_ACK messages
Description This counter counts the number of
ABIS_END_LOAD_CONTROL_ACK messages received by BSC.
Usage This counter is used to find out the frequency of END LOAD
CONTROL RETURN messages transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_END_LOAD_CONTROL_ACK messages to BTS. The
measurement point is A, as shown in Figure 34.

Confidential and Proprietary Information of ZTE CORPORATION 139


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Unit Times

C901280048
Definition Number of ABIS_PCCCH_LOAD_IND messages
Description This counter counts the number of PCCH flow control control
command messages of Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of PCCH flow
control control command messages transmitting on Abis
interface.
Measurement This counter increments when BSC receives
Point ABIS_PCCCH_LOAD_CONTROL_IND messages to BTS. The
measurement point is A, as shown in Figure 34.
Unit Times

C901280049
Definition Number of ABIS_RF_RESRC_IND messages
Description BTS sends RF RESOURCE INDICATION messages periodically to
inform BSC of interference on idle channel belonging to one TRX.
This counter counts the number of ABIS_RF_RESRC_ IND
messages of Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of RF RESOURCE
INDICATION messages transmitting on Abis interface.
Measurement This counter increments when BSC receives RF RESOURCE
Point INDICATION messages. The measurement point is A, as shown
in Figure 34.
Unit Times

C901280050
Definition Number of ABIS_SACCH_FILLING messages
Description When BSC modifies SI1/5bis/6/EXTENDED MEASUREMENT
ORDER message sent on SACCH, it sends one SACCH FILLING
message to BTS. This counter counts the number of SACCH
FILLING INFORMATION CHANGE messages of Abis interface
messages sent by BSC.
Usage This counter is used to find out the frequency of SACCH FILLING
INFORMATION CHANGE messages transmitting on Abis interface.
Measurement This counter increments when BSC sends SACCH FILLING
Point messages. The measurement point is A, as shown in Figure 35.
Unit Times

140 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

C901280051
Definition Number of ABIS_OVERLOAD messages
Description This counter counts the number of flow control messages of Abis
interface messages received by BSC.
Usage This counter is used to find out the frequency of flow control
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives overload messages.
Point The measurement point is A, as shown in Figure 34.
Unit Times

C901280052
Definition Number of ABIS_ERROR_REPORT messages
Description When BTS check some errors but it is impossible to report to
BSC through other processes, it sends one ERROR REPORT
message to BSC. This counter counts the number of
ABIS_ERROR_REPORT messages received by BSC.
Usage This counter is used to find out the frequency of error report
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives error report
Point messages. The measurement point is A, as shown in Figure 34.
Unit Times

C901280053
Definition Number of ABIS_SYSINFO_REQ messages
Description This counter counts the number of ABIS_SYSINFO_REQ
messages received by BSC.
Usage This counter is used to find out the frequency of systems
information requirement messages transmitting on Abis interface.
Measurement This counter increments when BSC receives ABIS_SYSINFO_REQ
Point messages. The measurement point is A, as shown in Figure 34.
Unit Times

C901280054
Definition Number of ABIS_SI_BC_END messages
Description This counter counts the number of ABIS_SI_BC_END indication
messages sent by BSC.

Confidential and Proprietary Information of ZTE CORPORATION 141


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Usage This counter is used to find out the frequency of systems


information broadcast end indication messages transmitting on
Abis interface.
Measurement This counter increments when BSC sends ABIS_SI_BC_END
Point messages to BTS. The measurement point is A, as shown in
Figure 35.
Unit Times

C901280055
Definition Number of ABIS_SI_NACK messages
Description This counter counts the number of ABIS_SI_NACK messages
received by BSC.
Usage This counter is used to find out the frequency of SI_NACK
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives ABIS_SI_NACK
Point messages to BTS. The measurement point is A, as shown in
Figure 34.
Unit Times

C901280056
Definition Number of ABIS_PWRCTRL_IND messages
Description This counter counts the number of ABIS_PWRCTRL_IND
messages received by BSC.
Usage This counter is used to find out the frequency of POWER
CONTROL INDICATION messages transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_PWRCTRL_IND messages. The measurement point is A, as
shown in Figure 34.
Unit Times

C901280057
Definition Number of ABIS_SYSINFO_ACK messages
Description This counter counts the number of ABIS_SYSINFO_ACK
messages received by BSC.
Usage This counter is used to find out the frequency of SYSTEM
INFORMATION ACKNOWLEDGE messages transmitting on Abis
interface.

142 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

Measurement This counter increments when BSC receives ABIS_SYSINFO_ACK


Point messages. The measurement point is A, as shown in Figure 34.
Unit Times

C901280061
Definition Number of ABIS_PACKET_PBCCH_INF messages
Description This counter counts the number of ABIS_PACKET_PBCCH_INF
messages received by BSC.
Usage This counter is used to find out the frequency of PACKET PBCCH
INFORMATION messages transmitting on Abis interface.
Measurement This counter increments when BSC sends
Point ABIS_PACKET_PBCCH_INF messages. The measurement point is
A, as shown in Figure 35.
Unit Times

C901280062
Definition Number of ABIS_PACKET_CCCH_PARA messages
Description This counter counts the number of ABIS_PACKET_CCCH_PARA
messages sent by BSC.
Usage This counter is used to find out the frequency of CCCH
INFORMATION messages transmitting on Abis interface.
Measurement This counter increments when BSC sends
Point ABIS_PACKET_CCCH_PARA messages. The measurement point
is A, as shown in Figure 35.
Unit Times

C901280063
Definition Number of ABIS_PACKET_PBCCH_PARA messages
Description This counter counts the number of ABIS_PACKET_PBCCH_PARA
messages sent by BSC.
Usage This counter is used to find out the frequency of PBCCH
PATAMETER messages transmitting on Abis interface.
Measurement This counter increments when BSC sends
Point ABIS_PACKET_PBCCH_PARA messages to BTS. The
measurement point is A, as shown in Figure 35.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 143


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901280064
Definition Number of ABIS_PACKET_CHN_REQ messages
Description This counter counts the number of ABIS_PACKET_CHN_REQ
messages received by BSC.
Usage This counter is used to find out the frequency of UL PACKET
CHANNEL REQUIREMENT messages transmitting on Abis
interface.
Measurement This counter increments when BSC receives
Point ABIS_PACKET_CHN_REQ messages to BTS. The measurement
point is A, as shown in Figure 34.
Unit Times

C901280065
Definition Number of ABIS_PACKET_PAGING_CMD messages
Description This counter counts the number of ABIS_PACKET_PAGING_CMD
messages received by BSC.
Usage This counter is used to find out the frequency of PACKET PAGING
COMMAND messages transmitting on Abis interface.
Measurement This counter increments when BSC sends
Point ABIS_PACKET_PAGING_CMD messages to BTS. The
measurement point is A, as shown in Figure 35.
Unit Times

C901280066
Definition Number of ABIS_PACKET_IMM_ASSIGN_CMD messages
Description This counter counts the number of PACKET IMMEDIATE
ASSIGNMENT messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of PACKET
IMMEDIATE ASSIGNMENT messages transmitting on Abis
interface.
Measurement This counter increments when BSC sends
Point ABIS_PACKET_IMM_ASSIGN_CMD messages to BTS. The
measurement point is A, as shown in Figure 35.
Unit Times

144 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

C901280067
Definition Number of ABIS_PACKET_CONNECT_FAIL_IND messages
Description This counter counts the number of PACKET CONNECT FAILURE
INDICATION messages of Abis interface messages received by
BSC.
Usage This counter is used to find out the frequency of PACKET
CONNECT FAILURE INDICATION messages transmitting on Abis
interface.
Measurement This counter increments when BSC receives
Point ABIS_PACKET_CONNECT_FAIL_IND messages to BTS. The
measurement point is A, as shown in Figure 34.
Unit Times

C901280068
Definition Number of ABIS_PACKET_PRACH_OVERLOAD messages
Description This counter counts the number of PRACH OVERLOAD messages
of Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of PRACH
OVERLOAD messages transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_PACKET_PRACH_OVERLOAD messages. The measurement
point is A, as shown in Figure 34.
Unit Times

C901280069
Definition Number of ABIS_PACKET_PCH_OVERLOAD messages
Description This counter counts the number of PCH OVERLOAD messages of
Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of PCH OVERLOAD
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_PACKET_PCH_OVERLOAD messages. The measurement
point is A, as shown in Figure 34.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 145


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901280070
Definition Number of ABIS_PACKET_TA_REQUEST messages
Description This counter counts the number of TIME ADVANCE REQUEST
messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of TIME ADVANCE
REQUEST messages transmitting on Abis interface.
Measurement This counter increments when BSC sends
Point ABIS_PACKET_TA_REQUEST messages. The measurement point
is A, as shown in Figure 35.
Unit Times

C901280071
Definition Number of ABIS_PACKET_TA_REQUEST_ACK messages
Description This counter counts the number of TIME ADVANCE REQUEST
ACKNOWLEDGE messages of Abis interface messages received
by BSC.
Usage This counter is used to find out the frequency of TIME ADVANCE
REQUEST ACKNOWLEDGE messages transmitting on Abis
interface.
Measurement This counter increments when BSC receives
Point ABIS_PACKET_TA_REQUEST_ACK messages. The measurement
point is A, as shown in Figure 34.
Unit Times

C901280072
Definition Number of ABIS_PACKET_CHN_CONFIG_CHG messages
Description This counter counts the number of CHANNEL CONFIGURATION
CHANGE messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of CHANNEL
CONFIGURATION CHANGE messages transmitting on Abis
interface.
Measurement This counter increments when BSC sends
Point ABIS_PACKET_CHG_CONFIG_CHG messages. The measurement
point is A, as shown in Figure 35.
Unit Times

146 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

C901280073
Definition Number of ABIS_PACKET_CHN_CONFIG_CHG_RESP messages
Description This counter counts the number of CHANNEL CONFIGURATION
CHANGE RESPONSE messages of Abis interface messages
received by BSC.
Usage This counter is used to find out the frequency of CHANNEL
CONFIGURATION CHANGE RESPONSE messages transmitting on
Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_PACKET_CHG_CONFIG_CHG_RESP messages. The
measurement point is A, as shown in Figure 34.
Unit Times

C901280074
Definition Number of ABIS_PACKET_PIA_DEL_IND messages
Description This counter counts the number of IMMEDIATE ASSIGNMENT
TRANSMISSION FAILURE INDICATION messages of Abis
interface messages received by BSC.
Usage This counter is used to find out the frequency of IMMEDIATE
ASSIGNMENT TRANSMISSION FAILURE INDICATION messages
transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_PACKET_PIA_DEL_IND messages. The measurement point
is A, as shown in Figure 34.
Unit Times

C901280075
Definition Number of ABIS_PACKET_SEND_PIA_IND messages
Description This counter counts the number of IMMEDIATE ASSIGNMENT
TRANSMISSION SUCCESS INDICATION messages of Abis
interface messages received by BSC.
Usage This counter is used to find out the frequency of IMMEDIATE
ASSIGNMENT TRANSMISSION SUCCESS INDICATION messages
transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_PACKET_SEND_PIA_IND messages. The measurement
point is A, as shown in Figure 34.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 147


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901280076
Definition Number of ABIS_PACKET_CHN_CONFIG_REQ messages
Description This counter counts the number of PS PARAMETER
CONFIGURATION REQUEST messages of Abis interface
messages received by BSC.
Usage This counter is used to find out the frequency of PS PARAMETER
CONFIGURATION REQUEST messages transmitting on Abis
interface.
Measurement This counter increments when BSC receives
Point ABIS_PACKET_CHN_CONFIG_REQ messages. The measurement
point is A, as shown in Figure 34.
Unit Times

C901280077
Definition Number of ABIS_EGPRS_PACKET_CHN_REQ messages
Description This counter counts the number of UL EGPRS PACKET REQUEST
messages of Abis interface messages received by BSC.
Usage This counter is used to find out the frequency of UL EGPRS
PACKET REQUEST messages transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_EGPRS_PACKET _CHN_REQ messages. The measurement
point is A, as shown in Figure 34.
Unit Times

C901280078
Definition Number of ABIS_PS_CHANNEL_ACTIVE messages
Description This counter counts the number of PS CHANNEL ACTIVE
COMMAND messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of PS CHANNEL
ACTIVE COMMAND messages transmitting on Abis interface.
Measurement This counter increments when BSC sends ABIS_PS_CHANNEL
Point _ACTIVE messages. The measurement point is A, as shown in
Figure 35.
Unit Times

148 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

C901280079
Definition Number of ABIS_PS_CHANNEL_ACTIVE_ACK messages
Description This counter counts the number of PS CHANNEL ACTIVE
ACKNOWLEDGEMENT COMMAND messages of Abis interface
messages sent by BSC.
Usage This counter is used to find out the frequency of PS CHANNEL
ACTIVE ACKNOWLEDGEMENT COMMAND messages transmitting
on Abis interface.
Measurement This counter increments when BSC receives ABIS_PS_CHANNEL
Point _ACTIVE_ACK messages. The measurement point is A, as shown
in Figure 34.
Unit Times

C901280080
Definition Number of ABIS_PS_CHANNEL_ACTIVE_NACK messages
Description This counter counts the number of PS CHANNEL ACTIVE
UNACKNOWLEDGEMENT COMMAND messages of Abis interface
messages received by BSC.
Usage This counter is used to find out the frequency of PS CHANNEL
ACTIVE UNACKNOWLEDGEMENT COMMAND messages
transmitting on Abis interface.
Measurement This counter increments when BSC receives ABIS_PS_CHANNEL
Point _ACTIVE_NACK messages. The measurement point is A, as
shown in Figure 34.
Unit Times

C901280081
Definition Number of ABIS_PS_CHANNEL_RELEASE messages
Description This counter counts the number of PS CHANNEL RELEASE
COMMAND messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of PS CHANNEL
RELEASE COMMAND messages transmitting on Abis interface.
Measurement This counter increments when BSC sends
Point ABIS_PS_CHANNEL_RELEASE messages to BTS. The
measurement point is A, as shown in Figure 35.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 149


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901280082
Definition Number of ABIS_PS_CHANNEL_RELEASE_ACK messages
Description This counter counts the number of PS CHANNEL RELEASE
ACKNOWLEDGEMENT COMMAND messages of Abis interface
messages received by BSC.
Usage This counter is used to find out the frequency of PS CHANNEL
RELEASE ACKNOWLEDGEMENT COMMAND messages
transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_PS_CHANNEL_RELEASE_ACK messages. The measurement
point is A, as shown in Figure 34.
Unit Times

C901280083
Definition Number of ABIS_PS_CHANNEL_RELEASE_NACK messages
Description This counter counts the number of PS CHANNEL RELEASE
UNACKNOWLEDGEMENT COMMAND messages of Abis interface
messages received by BSC.
Usage This counter is used to find out the frequency of PS CHANNEL
RELEASE UNACKNOWLEDGEMENT COMMAND messages
transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_PS_CHANNEL_RELEASE_NACK messages. The
measurement point is A, as shown in Figure 34.
Unit Times

C901280084
Definition Number of ABIS_PSCONN_CMM_REQ messages
Description This counter counts the number of PS CONNECTION COMMAND
messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of PS
CONNECTION COMMAND messages transmitting on Abis
interface.
Measurement This counter increments when BSC sends
Point ABIS_PSCONN_CMM_REQ messages to BTS. The measurement
point is A, as shown in Figure 35.
Unit Times

150 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

C901280085
Definition Number of ABIS_PSCONN_CMM_ACK messages
Description This counter counts the number of PS CONNECTION SUCCESS
COMMAND ACKNOWLEDGEMENT messages of Abis interface
messages sent by BSC.
Usage This counter is used to find out the frequency of PS
CONNECTION SUCCESS COMMAND ACKNOWLEDGEMENT
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_PSCONN_CMM_ACK messages. The measurement point is
A, as shown in Figure 34.
Unit Times

C901280086
Definition Number of ABIS_PSCONN_CMM_NACK messages
Description This counter counts the number of PS CONNECTION FAILURE
COMMAND ACKNOWLEDGEMENT messages of Abis interface
messages sent by BSC.
Usage This counter is used to find out the frequency of PS
CONNECTION FAILURE COMMAND ACKNOWLEDGEMENT
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_PSCONN_CMM_NACK messages. The measurement point
is A, as shown in Figure 34.
Unit Times

C901280087
Definition Number of ABIS_GLOBAL_RESET messages
Description This counter counts the number of GLOBAL RESET COMMAND
messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of GLOBAL RESET
COMMAND messages transmitting on Abis interface.
Measurement This counter increments when BSC sends ABIS_GLOBAL_RESET
Point messages to BTS. The measurement point is A, as shown in
Figure 35.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 151


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901280088
Definition Number of ABIS_GLOBAL_RESET_ACK messages
Description This counter counts the number of GLOBAL RESET
ACKNOWLEDGEMENT COMMAND messages of Abis interface
messages sent by BSC.
Usage This counter is used to find out the frequency of GLOBAL RESET
ACKNOWLEDGEMENT COMMAND messages transmitting on Abis
interface.
Measurement This counter increments when BSC receives
Point ABIS_GLOBAL_RESET_ACK messages. The measurement point
is A, as shown in Figure 34.
Unit Times

C901280089
Definition Number of ABIS_GLOBAL_RESET_NACK messages
Description This counter counts the number of GLOBAL RESET
UNACKNOWLEDGEMENT COMMAND messages of Abis interface
messages sent by BSC.
Usage This counter is used to find out the frequency of GLOBAL RESET
UNACKNOWLEDGEMENT COMMAND messages transmitting on
Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_GLOBAL_RESET_NACK messages. The measurement point
is A, as shown in Figure 34.
Unit Times

C901280090
Definition Number of ABIS_PACKET_UP_ASSIGN messages
Description This counter counts the number of PS UL ASSIGNMENT
COMMAND messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of PS UL
ASSIGNMENT COMMAND messages transmitting on Abis
interface.
Measurement This counter increments when BSC sends
Point ABIS_PACKET_UP_ASSIGN messages to BTS. The measurement
point is A, as shown in Figure 35.
Unit Times

152 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

C901280091
Definition Number of ABIS_PACKET_DOWN_ASSIGN messages
Description This counter counts the number of PS DL ASSIGNMENT
COMMAND messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of PS DL
ASSIGNMENT COMMAND messages transmitting on Abis
interface.
Measurement This counter increments when BSC sends
Point ABIS_PACKET_DOWN_ASSIGN messages to BTS. The
measurement point is A, as shown in Figure 35.
Unit Times

C901280092
Definition Number of ABIS_CSCONN_CMM_REQ messages
Description This counter counts the number of CS CONNECTION COMMAND
messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of CS
CONNECTION COMMAND messages transmitting on Abis
interface.
Measurement This counter increments when BSC sends
Point ABIS_CSCONN_CMM_REQ messages to BTS. The measurement
point is A, as shown in Figure 35.
Unit Times

C901280093
Definition Number of ABIS_CSCONN_CMM_ACK messages
Description This counter counts the number of CS CONNECTION SUCCESS
COMMAND ACKNOWLEDGEMENT messages of Abis interface
messages received by BSC.
Usage This counter is used to find out the frequency of CS
CONNECTION SUCCESS COMMAND ACKNOWLEDGEMENT
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_CSCONN_CMM_ACK messages. The measurement point is
A, as shown in Figure 34.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 153


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901280094
Definition Number of ABIS_CSCONN_CMM_NACK messages
Description This counter counts the number of CS CONNECTION FAILURE
COMMAND ACKNOWLEDGEMENT messages of Abis interface
messages received by BSC.
Usage This counter is used to find out the frequency of CS
CONNECTION FAILURE COMMAND ACKNOWLEDGEMENT
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_CSCONN_CMM_NACK messages. The measurement point
is A, as shown in Figure 34.
Unit Times

C901280095
Definition Number of ABIS_CCMCONN_CMM_REQ messages
Description This counter counts the number of CCM CONNECTION
COMMAND messages of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of CCM
CONNECTION COMMAND messages transmitting on Abis
interface.
Measurement This counter increments when BSC sends
Point ABIS_CCMCONN_CMM_REQ messages to BTS. The
measurement point is A, as shown in Figure 35.
Unit Times

C901280096
Definition Number of ABIS_CCMCONN_CMM_ACK messages
Description This counter counts the number of CCM CONNECTION SUCCESS
COMMAND ACKNOWLEDGEMENT messages of Abis interface
messages received by BSC.
Usage This counter is used to find out the frequency of CCM
CONNECTION SUCCESS COMMAND ACKNOWLEDGEMENT
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_CCMCONN_CMM_ACK messages. The measurement point
is A, as shown in Figure 34.
Unit Times

154 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - Abis Interface Message Counter Measurement

C901280097
Definition Number of ABIS_CCMCONN_CMM_NACK messages
Description This counter counts the number of CCM CONNECTION FAILURE
COMMAND ACKNOWLEDGEMENT messages of Abis interface
messages received by BSC.
Usage This counter is used to find out the frequency of CCM
CONNECTION FAILURE COMMAND ACKNOWLEDGEMENT
messages transmitting on Abis interface.
Measurement This counter increments when BSC receives
Point ABIS_CCMCONN_CMM_NACK messages. The measurement point
is A, as shown in Figure 34.
Unit Times

C901280098
Definition Number ABIS_PACKET_ACCESS_REJ messages
Description This counter counts the number of PS ACCESS REJECT messages
of Abis interface messages sent by BSC.
Usage This counter is used to find out the frequency of PS ACCESS
REJECT messages transmitting on Abis interface.
Measurement This counter increments when BSC sends
Point ABIS_PACKET_ACCESS_REJ messages to BSC. The
measurement point is A, as shown in Figure 35.
Unit Times

C901280099
Definition Number of ABIS_PACKET_IMM_ASSIGN_CMD_NEW messages
Description This counter counts the number of new packet immediate
assignment messages in the Abis interface messages sent by
BSC.
Usage The counter is used to find out the frequency of new packet
immediate assignment messages transmitted at Abis interface.
Measurement When BSC sends the ABIS_PACKET_IMM_ASSIGN_CMD_NEW
Point message to BTS, the counter increments. The measurement
point is A, as shown in Figure 35.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 155


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

C901280100
Definition Number of PACKET_DOWNLINK_ASSIGN messages
Description This counter counts the number of packet downlink assignment
messages in the Abis interface messages sent by BSC.
Usage The counter is used to find out the frequency of packet downlink
assignment messages transmitted at Abis interface.
Measurement When BSC sends the PACKET_DOWNLINK_ASSIGN message to
Point BTS, the counter increments. The measurement point is A, as
shown in Figure 35.
Unit Times

C901280101
Definition Number of PACKET_UPLINK_ASSIGN messages
Description This counter counts the number of packet uplink assignment
messages in the Abis interface messages sent by BSC.
Usage The counter is used to find out the frequency of packet uplink
assignment messages transmitted at Abis interface.
Measurement When BSC sends the PACKET_UPLINK_ASSIGN message to BTS,
Point the counter increments. The measurement point is A, as shown
in Figure 35.
Unit Times

C901280102
Definition Number of ABIS_PACKET_ACCESS_REJ_NEW messages
Description This counter counts the number of new PS access reject
messages in the Abis interface messages sent by BSC.
Usage The counter is used to find out the frequency of new PS access
reject messages transmitted at Abis interface.
Measurement When BSC sends the ABIS_PACKET_ACCESS_REJ_NEW message
Point to BTS, the counter increments. The measurement point is A, as
shown in Figure 35.
Unit Times

156 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6

Gb Message Statistics
(BVC Cell)

Gb message statistics measurement task considers cell as


measurement entity, to measure transmission condition of PTP
message at Gb BSSGP level. This chapter introduces the
meaning, usage, and measurement point of different counters
for Gb message statistic.

Overview
Gb message statistics mainly measures transmission number of
different PTP messages at Gb BSSGP level in GPRS service (such
as RA-CAPABILITY, RADIO-STATUS, DOWNLOAD-BSS-PFC).
The measurement takes BVC cell as the statistics unit.

Gb Message Statistics Counter


Index
Table 10 lists counters related to Gb message statistics.

TABLE 10 - GB MESSAGE STATISTICS COUNTER

Counter ID What It Counts


Sum of UL UNITDATA messages handled at BSSGP
C901290001
level
Sum of DL UNITDATA messages handled at BSSGP
C901290002
level
C901290003 Number of RA-CAPABILITY message received
C901290004 Number of PTP packet paging received by BSC
C901290005 Number of PTP circuit paging received by BSC
C901290006 Number of RA-CAPABILITY-UPDATE message sent
C901290007 Number of RA-CAPABILITY-UPDATE-ACK message

Confidential and Proprietary Information of ZTE CORPORATION 157


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Counter ID What It Counts


received
Number of Wireless Status PDU messages sent by
C901290008
BSC
Number of Wireless Status messages sent by BSC
C901290009
due to Losing Wireless Association with MS
Number of wireless status messages sent by BSC due
C901290010
to Bad Link Quality
Number of Wireless status messages sent by BSC
C901290011
due to Cell reselection command
Number of FLOW-CONTROL-BVC messages sent by
C901290012
BSC
Number of FLOW-CONTROL-BVC-ACK messages
C901290013
received by BSC
Number of FLOW-CONTROL-MS messages sent by
C901290014
BSC
Number of FLOW-CONTROL-MS-ACK messages
C901290015
received by BSC
Number of FLOW-CONTROL-PFC messages sent by
C901290016
BSC
Number of FLOW-CONTROL-PFC-ACK messages
C901290017
received by BSC
C901290018 Number of Status messages sent by BSC
C901290019 Number of Status messages received by BSC
C901290020 Number of Status messages sent with BVCI Unknown
Number of Status messages sent with Cell service
C901290021
congestion
C901290022 Number of Status messages sent with protocol error
Number of Status messages sent with Processor
C901290023
overload
Number of Status messages received with BVCI
C901290024
Unknown
Number of Status messages received with Cell
C901290025
service congestion
Number of Status messages received with protocol
C901290026
error
Number of Status messages received with Processor
C901290027
overload
Number of DOWNLOAD-BSS-PFC messages sent by
C901290028
BSC
Number of BVCCREATE-BSS-PFC messages received
C901290029
by BSC
Number of CREATE-BSS-PFC-ACK messages sent by
C901290030
BSC
C901290031 Number of CREATE-BSS-PFC-NACK messages sent by

158 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Gb Message Statistics (BVC Cell)

Counter ID What It Counts


BSC
C901290032 Number of MODIFY-BSS-PFC messages sent by BSC
Number of MODIFY-BSS-PFC-ACK messages received
C901290033
by BSC
Number of DELETE-BSS-PFC messages received by
C901290034
BSC
Number of DELETE -BSS-PFC-ACK messages sent by
C901290035
BSC
Number of DELETE -BSS-PFC-REQ messages received
C901290036
by BSC

C901290001
Definition Sum of UL UNITDATA messages handled at BSSGP level
Description This counter counts the number of sending UL-UNITDATA PDU to
SGSN by BSC.
Measurement When BSC sends a “UL-UNITDATA” message, this counter
Point increments. The measurement point is A, as shown in Figure 36.

FIGURE 36 - MEASUREMENT POINT OF SUM OF UL UNITD AT A MESSAGE


HANDLED AT BSSGP LEVEL

MS BTS BSC
CHL_REQ
CHL_RQD
A1
CHL_ACT

CHL_ACT_ACK
A2
IMM_ASS_CMD
IMM_ASS

SABM EST_IND

A3

Unit Times

C901290002
Definition Sum of DL UNITDATA messages handled at BSSGP level
Description SGSN sends DL-UNITDATA PDU to BSC, and this counter counts
the number of receiving this message by BSC.
Measurement When BSC receives a “DL-UNITDATA” message, this counter increments.
Point The measurement point is A, as shown in Figure 37.

Confidential and Proprietary Information of ZTE CORPORATION 159


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

FIGURE 37 - MEASUREMENT POINT OF SUM OF DL UNITD AT A MESSAGE


HANDLED AT BSSGP LEVEL

Unit Times

C901290003
Definition Number of RA-CAPABILITY message received
Description SGSN sends RA-CAPABILITY message to BSC, to indicate
wireless capability of MS. This counter counts the number of
receiving this message.
Measurement When BSC receives a “RA-CAPABILITY” message, this counter
Point increments. The measurement point is A, as shown in Figure 38.

FIGURE 38 - MEASUREMENT POINT OF THE NUMBER OF R A-C AP ABILITY


MESSAGE RECEIVED

Unit Times

C901290004
Definition Number of PTP packet paging received by BSC
Description SGSN sends PTP packet paging message, to indicate BSC
originate PTP packet paging for MS. This counter counts the
number of receiving this message by BSC.
Measurement When BSC receives a “PAGING PS” message, this counter
Point increments. The measurement point is A, as shown in Figure 39.

FIGURE 39 - PTP P ACKET PAGING PROCESS

BSC SGSN

PAGING PS

Unit Times

160 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Gb Message Statistics (BVC Cell)

C901290005
Definition Number of PTP circuit paging received by BSC
Description SGSN sends PTP circuit paging message, to indicate BSC
originate PTP circuit paging for MS. This counter counts the
number of receiving this message by BSC.
Measurement When BSC receives a “PAGING CS” message, this counter
Point increments. The measurement point is A, as shown in Figure 40.

FIGURE 40 - PTP CIRCUIT PAGING PROCESS

Unit Times

C901290006
Definition Number of RA-CAPABILITY-UPDATE message sent
Description SGSN sends RA-CAPABILITY-UPDATE message to SGSN, to
indicate current wireless capability of MS. This counter counts
the number of sending this message by BSC.
Measurement When BSC sends a “RA-CAPABILITY-UPDATE” message to SGSN,
Point this counter increments. The measurement point is A1, as shown
in Figure 41.

FIGURE 41 - RA-C AP ABILITY-UPDATE PROCESS

Unit Times

C901290007
Definition Number of RA-CAPABILITY-UPDATE-ACK message received
Description

Confidential and Proprietary Information of ZTE CORPORATION 161


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

SGSN sends RA-CAPABILITY-UPDATE-ACK message to BSC, to


indicate current wireless capability of MS. This counter counts
the number of receiving this message by BSC.
Measurement When BSC sends a “RA-CAPABILITY-UPDATE-ACK” message
Point from SGSN, this counter increments. The measurement point is
A2, as shown in Figure 41.
Unit Times

C901290008
Definition Number of Wireless Status PDU messages sent by BSC
Description BSC sends wireless status PDU message, to indicate exception at
SGSN radio interface. This counter counts the number of sending
this message by BSC.
Usage View the status at radio interface by counting this message.
Measurement When BSC sends a “RADIO-STATUS” message to SGSN, this
Point counter increments. The measurement point is A, as shown in
Figure 42.

FIGURE 42 - RADIO-ST ATUS PROCESS

Unit Times

C901290009
Definition Number of Wireless Status messages sent by BSC due to Losing
Wireless Association with MS
Description BSC sends wireless status message, to indicate exception
occurred at SGSN radio interface. This counter counts the
number of sending this message by BSC due to “Losing wireless
association with MS”.
Usage View the status at radio interface by counting this message.
Measurement When BSC sends a RADIO-STATUS message due to “Losing
Point wireless association with MS”, this counter increments.
Unit Times

162 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Gb Message Statistics (BVC Cell)

C901290010
Definition Number of wireless status messages sent by BSC due to Bad
Link Quality
Description BSC sends wireless status message, to indicate exception
occurred at SGSN radio interface. This counter counts the
number of sending this message by BSC due to “bad link
quality”.
Usage View the status at radio interface by counting this message.
Measurement When BSC sends a RADIO-STATUS message to SGSN due to
Point “bad link quality”, this counter increments.
Unit Times

C901290011
Definition Number of Wireless status messages sent by BSC due to Cell
reselection command
Description BSC sends wireless status message, to indicate exception
occurred at SGSN radio interface. This counter counts the
number of sending this message by BSC due to “cell reselection
command”.
Usage View the status at radio interface by counting this message.
Measurement When BSC sends a RADIO-STATUS message to SGSN due to
Point “cell reselection command”, this counter increments.
Unit Times

C901290012
Definition Number of FLOW-CONTROL-BVC messages sent by BSC
Description BSC sends FLOW-CONTROL-BVC message to notify SGSN of flow
control policy for current BVC. This counter counts the number
of sending this message by BSC.
Measurement When BSC sends a “FLOW-CONTROL-BVC” message, this
Point counter increments, as A1 measurement position shown in
Figure 42.
Unit Times

C901290013
Definition Number of FLOW-CONTROL-BVC-ACK messages received by BSC

Confidential and Proprietary Information of ZTE CORPORATION 163


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Description BSC sends FLOW-CONTROL-BVC-ACK message to notify BSC of


accepted flow control policy for current BVC. This counter counts
the number of receiving this message by BSC.
Measurement When BSC receives a “FLOW-CONTROL-BVC-ACK” message, this
Point counter increments. The measurement point is A2, as shown in
Figure 43.

FIGURE 43 - FLOW-CONTROL-BVC PROCESS

BSC SGSN
FLOW-CONTROL-BVC

A1
FLOW-CONTROL-BVC-ACK
A2

Unit Times

C901290014
Definition Number of FLOW-CONTROL-MS messages sent by BSC
Description BSC sends FLOW-CONTROL- MS message to notify SGSN of flow
control policy for current MS. This counter counts the number of
sending this message by BSC.
Measurement When BSC sends a “FLOW-CONTROL-MS” message, this counter
Point increments. The measurement point is A1, as shown in Figure 44.

FIGURE 44 - FLOW-CONTROL-MS PROCESS

Unit Times

C901290015
Definition Number of FLOW-CONTROL-MS-ACK messages received by BSC
Description BSC sends FLOW-CONTROL-MS-ACK message to notify BSC of
accepted flow control policy for current MS. This counter counts
the number of receiving this message by BSC.
Measurement
Point

164 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Gb Message Statistics (BVC Cell)

When BSC receives a “FLOW-CONTROL-MS-ACK” message, this


counter increments. The measurement point is A2, as shown in
Figure 44.
Unit Times

C901290016
Definition Number of FLOW-CONTROL- PFC messages sent by BSC
Description BSC sends FLOW-CONTROL-PFC message to notify SGSN of flow
control policy for one or more PFC for designated MS. This
counter counts the number of sending this message by BSC.
Measurement When BSC sends a “FLOW-CONTROL-PFC” message, this counter
Point increments. The measurement point is A1, as shown in Figure 45.

FIGURE 45 - FLOW-CONTROL-PFC PROCESS

Unit Times

C901290017
Definition Number of FLOW-CONTROL-PFC-ACK messages received by BSC
Description BSC sends FLOW-CONTROL-PFC-ACK message to notify BSC of
accepted PFC flow control policy for designated MS. This counter
counts the number of receiving this message by BSC.
Measurement When BSC receives a “FLOW-CONTROL-PFC-ACK” message, this
Point counter increments. The measurement point is A2, as shown in
Figure 45.
Unit Times

C901290018
Definition Number of Status messages sent by BSC
Description BSC sends status message to SGSN, to indicate exception
occurred. This counter counts the number of sending this
message by BSC.

Confidential and Proprietary Information of ZTE CORPORATION 165


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Measurement When BSC sends a “STATUS” message, this counter increments.


Point The measurement point is A1, as shown in Figure 46.

FIGURE 46 - ST ATUS PROCESS

Unit Times

C901290019
Definition Number of Status messages received by BSC
Description SGSN sends status message to BSC, to indicate exception
occurred. This counter counts the number of receiving this
message by BSC.
Measurement When BSC receives a “STATUS” message, this counter
Point increments. The measurement point is A2, as shown in Figure 46.
Unit Times

C901290020
Definition Number of Status messages sent with BVCI Unknown
Description BSC sends status message to SGSN, to indicate exception
occurred. This counter counts the number of sending this
message by BSC due to “BVCI Unknown”.
Measurement When BSC sends a STATUS message due to “BVCI Unknown”,
Point this counter increments.
Unit Times

C901290021
Definition Number of Status messages sent with Cell service congestion
Description BSC sends status message to SGSN, to indicate exception
occurred. This counter counts the number of sending this
message by BSC due to “cell service congestion”.
Measurement When BSC sends a STATUS message due to “cell service
Point congestion”, this counter increments.

166 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Gb Message Statistics (BVC Cell)

Unit Times

C901290022
Definition Number of Status messages sent with protocol error
Description BSC sends status message to SGSN, to indicate exception
occurred. This counter counts the number of sending this
message by BSC due to “protocol error”.
Measurement When BSC sends a STATUS message due to “protocol error”, this
Point counter increments.
Unit Times

C901290023
Definition Number of Status messages sent with Processor overload
Description BSC sends status message to SGSN, to indicate exception
occurred. This counter counts the number of sending this
message by BSC due to “processor overload”.
Measurement When BSC sends a STATUS message due to “processor
Point overload”, this counter increments.
Unit Times

C901290024
Definition Number of Status messages received with BVCI Unknown
Description SGSN sends status message to BSC, to indicate exception
occurred. This counter counts the number of receiving this
message by BSC due to “BVCI Unknown”.
Measurement When BSC receives a STATUS message due to “BVCI Unknown”,
Point this counter increments.
Unit Times

C901290025
Definition Number of Status messages received with Cell service
congestion
Description SGSN sends status message to BSC, to indicate exception
occurred. This counter counts the number of receiving this
message by BSC due to “cell service congestion”.

Confidential and Proprietary Information of ZTE CORPORATION 167


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Measurement When BSC receives a STATUS message due to “cell service


Point congestion”, this counter increments.
Unit Times

C901290026
Definition Number of Status messages received with protocol error
Description SGSN sends status message to BSC, to indicate exception
occurred. This counter counts the number of receiving this
message by BSC due to “protocol error”.
Measurement When BSC receives a STATUS message due to “protocol error”,
Point this counter increments.
Unit Times

C901290027
Definition Number of Status messages received with cause “Processor
overload”
Description SGSN sends status message to BSC, to indicate exception
occurred. This counter counts the number of receiving this
message by BSC due to “processor overload”.
Measurement When BSC receives a STATUS message due to “processor
Point overload”, this counter increments.
Unit Times

C901290028
Definition Number of DOWNLOAD-BSS-PFC messages sent by BSC
Description BSC sends DOWNLOAD-BSS-PFC message, to request SGSN
originate CREATE-BSS-PFC process. This counter counts the
number of sending this message by BSC.
Measurement When BSC sends a “DOWNLOAD-BSS-PFC” message, this
Point counter increments. The measurement point is A1, as shown in
Figure 47.

168 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Gb Message Statistics (BVC Cell)

FIGURE 47 - CRE ATE-BSS-PFC PROCESS

BSC SGSN
DOWNLOAD-BSS-PFC

A1 CREATE-BSS-PFC

A2
CREATE-BSS-PFC-ACK

A3 CREATE-BSS-PFC-NACK
A4

Unit Times

C901290029
Definition Number of BVCCREATE-BSS-PFC messages received by BSC
Description SGSN sends CREATE-BSS-PFC message to request BSC create or
modify a packet flow control context. This counter counts the
number of receiving this message by BSC.
Measurement When BSC receives a “CREATE-BSS-PFC” message, this counter
Point increments. The measurement point is A2, as shown in Figure 47.
Unit Times

C901290030
Definition Number of CREATE-BSS-PFC-ACK messages sent by BSC
Description BSC sends CREATE-BSS-PFC-ACK message to affirm SGSN
create or modify a request of packet flow control context. This
counter counts the number of sending this message by BSC.
Measurement When BSC sends a “CREATE-BSS-PFC-ACK” message, this
Point counter increments. The measurement point is A3, as shown in
Figure 47.
Unit Times

C901290031
Definition Number of CREATE-BSS-PFC-NACK messages sent by BSC
Description BSC sends CREATE-BSS-PFC-NACK message to deny SGSN
create or modify a request of packet flow control context. This
counter counts the number of sending this message by BSC.

Confidential and Proprietary Information of ZTE CORPORATION 169


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Measurement When BSC sends a “CREATE-BSS-PFC-NACK” message, this


Point counter increments. The measurement point is A4, as shown in
Figure 47.
Unit Times

C901290032
Definition Number of MODIFY-BSS-PFC messages sent by BSC
Description BSC sends MODIFY-BSS-PFC message to SGSN to request
modify packet flow control context. This counter counts the
number of sending this message by BSC.
Measurement When BSC sends a “MODIFY-BSS-PFC” message, this counter
Point increments. The measurement point is A1, as shown in Figure 48.

FIGURE 48 - MODIFY-BSS-PFC PROCESS

Unit Times

C901290033
Definition Number of MODIFY-BSS-PFC-ACK messages received by BSC
Description SGSN sends MODIFY-BSS-PFC-ACK message to BSC to confirm
the modification of packet flow control context. This counter
counts the number of receiving this message by BSC.
Measurement When BSC receives a “MODIFY-BSS-PFC-ACK” message, this
Point counter increments. The measurement point is A2, as shown in
Figure 48.
Unit Times

C901290034
Definition Number of DELETE-BSS-PFC messages received by BSC
Description SGSN sends DELETE-BSS-PFC message to request BSC delete a
packet flow control context. This counter counts the number of
receiving this message by BSC.

170 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - Gb Message Statistics (BVC Cell)

Measurement When BSC receives a “DELETE-BSS-PFC” message, this counter


Point increments. The measurement point is A1, as shown in Figure 49.

FIGURE 49 - DELETE-BSS-PFC PROCESS

BSC SGSN
DELETE-BSS-PFC

A1
DELETE-BSS-PFC-ACK

A2

Unit Times

C901290035
Definition Number of DELETE -BSS-PFC-ACK messages sent by BSC
Description BSC sends DELETE-BSS-PFC-ACK message to SGSN to confirm
the deletion of packet flow control context. This counter counts
the number of sending this message by BSC.
Measurement When BSC sends a “DELETE-BSS-PFC-ACK” message, this
Point counter increments. The measurement point is A2, as shown in
Figure 49.
Unit Times

C901290036
Definition Number of DELETE-BSS-PFC-REQ messages received by BSC
Description This counter is not used.

Confidential and Proprietary Information of ZTE CORPORATION 171


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

This page is intentionally blank.

172 Confidential and Proprietary Information of ZTE CORPORATION


Appendix A

Abbreviations

Abbreviation Full Name


A
Abis Abis Interface
AIPP A-Interface Peripheral Processor
AIU A-Interface Unit
AUC Access Unit Controller
B
BCCH Broadcast Channel
BSC Base Station Controller
BTS Base Transceiver Station
BSSAP Base Station Subsystem Application Part
BSSGP Base Station Subsystem GPRS Protocol
BSSMAP Base Station Subsystem Management
Application Part
BTS Base Transceiver Station
BVC BSSGP Virtual Connection
BVCI BSSGP Virtual Connection Identifier
C
CBCH Cell Broadcast Channel
CC Call Control
CCCH Common Control Channel
CCH Control Channel
CS Circuit Switched
D
DRT Dual Rate Transcoder
DTAP Direct Transfer Application Part
E

Confidential and Proprietary Information of ZTE CORPORATION 173


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Abbreviation Full Name


EDRT Enhanced Dual Rate Transcoder
EGSM Extended GSM
F
FACCH Fast Associated Control Channel
FACCH/F Fast Associated Control Channel/Full rate
FACCH/H Fast Associated Control Channel/Half rate
FR Frame Relay
FRP Frame Relay Protocol
FU Frame Unit
G
GGSN Gateway GPRS Support Node
GIU GPRS Interface Unit
GPRS General Packet Radio Service
GSM Global System for Mobile communication
GSN GPRS Support Node
H
HSN Hopping Sequence Number
K
KPI Key Performance Indicator
L
LAPD Link Access Protocol of D-Channel
LLC Logical Link Control
LMT Local Management Terminal
LOC Location update
M
MM Mobility Management
MOC Mobile Originated Call
MS Mobile Station
MSC Mobile Switching Center
MO-SM MS Originated Short Message
MT-SM MS Terminated Short Message
MTC Mobile Terminated Call
MTP Message Transfer Part
N
NC Network Controller
NMS Network Management Signaling
NMS Network Management Software

174 Confidential and Proprietary Information of ZTE CORPORATION


Appendix A - Abbreviations

Abbreviation Full Name


NS Network Service
NSE Network Service Entity
NSEI Network Service Entity Identifier
NSVC Network Service Virtual Circuit
O
OMC Operation Maintenance Center
OMCR Operation Maintenance Center Radio
P
PACCH Packet Associated Control Channel
PAGCH Paging and Access Grant Channel
PBGT Power Budget
PCH Paging Channel
PCU Packet Control Unit
PDU Protocol Data Unit
PDCH Packet Data Channel
PDTCH Packet Data Traffic Channel
PDU Protocol Data Unit
PS Packet Switched
R
RMM Radio Management Module
RQ Receiving Quality
RR Radio Resource
S
SACCH Slow Associated Control Channel
SACCH/F Slow Associated Control Channel/Full rate
SACCH/H Slow Associated Control Channel/Half rate
SAPI Service Access Point Identifier
SCCP Signal Correction Control Part
SDCCH Slow Distributed Control Channel
SGSN Serving GPRS Support Node
SIF Service Information Field
SIO Service Information Octets
SM Short Message
SMM Service Management Module
SMS Short Messages Service
SS Supplementary Services
T

Confidential and Proprietary Information of ZTE CORPORATION 175


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Abbreviation Full Name


TA Time Advance
TCH Traffic Channel
TCH/F Traffic Channel/Full rate
TCH/H Traffic Channel/Half rate
TFO Tandem Free Operation
TIC Trunk Interface Circuit
TRX Transceiver
U
UISF User Interface Support Foundation

176 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B

Figures

Figure 1 - BSC Receives the measurement report submitted by


BTS ..................................................................................3
Figure 2 – Immediate Assignment Failure Measurement Point . 10
Figure 3 – Assignment Failure Measurement Point ................. 11
Figure 4 –Handovers Failure Measurement Point ................... 12
Figure 5 – Resource Indication Measurement Point ................ 12
Figure 6 – Call Drop due to Radio Link Failure during Immediate
Assignment Process .......................................................... 17
Figure 7 – Call Drop due to Radio Link Failure during Assignment
Process ........................................................................... 18
Figure 8 – BSC Receives Measurement Report from BTS......... 21
Figure 9 – Measurement Point when Channel Is Activated ...... 21
Figure 10 – The Process Of Immediate Assignment ............... 23
Figure 11 –The Process Of Internal Handover (like intra-cell
handover) ....................................................................... 24
Figure 12 –The Process Of External Handover ....................... 24
Figure 13 - Immediate assignment flow ............................... 31
Figure 14 - Common assignment flow (internal TC) ............... 32
Figure 15 - Common assignment flow (external TC) .............. 32
Figure 16 - Internal handover (like intra-cell handover) flow
(internal TC) .................................................................... 33
Figure 17 - Internal handover (during Intra-cell handover, and
channel types are changed) flow (external TC) ..................... 33
Figure 18 - External handover flow (internal TC) ................... 34
Figure 19 - External handover flow (external TC) .................. 34
Figure 20 - Internal handover (internal TC intra-cell handover)
failure flow 1 ................................................................... 43
Figure 21 - External handover failure flow (internal TC).......... 43

Confidential and Proprietary Information of ZTE CORPORATION 177


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

Figure 22 - Internal handover (internal TC intra-cell handover)


failure flow 2 ................................................................... 44
Figure 23 - Internal handover (internal TC intra-cell handover)
failure flow 3 ................................................................... 44
Figure 24 - General Assignment Failure Flow 1 (external TC) .. 56
Figure 25 - General Assignment Failure Flow 2 (external TC) .. 56
Figure 26 - Internal handover (external TC intra-cell handover,
and channel types are changed) failure flow 1 ...................... 57
Figure 27 - External handover flow (external TC) .................. 58
Figure 28 - Internal handover (external TC intra-cell handover,
and channel types are changed) failure flow 2 ...................... 59
Figure 29 - External handover failure flow 2 (external TC) ...... 59
Figure 30 - Request Resource Failure................................... 63
Figure 31 - Channel allocation failure .................................. 64
Figure 32 - Internal handover (internal TC intra-cell handover)
failure flow 1 ................................................................... 85
Figure 33 - External handover failure flow 2 (internal TC)....... 85
Figure 34 - BTS sends measurement point of Abis message to
BSC.............................................................................. 119
Figure 35 – Measurement Point when BSC Sends Abis Message
to BTS .......................................................................... 119
Figure 36 - Measurement point of sum of UL UNITDATA message
handled at BSSGP level ................................................... 159
Figure 37 - Measurement point of sum of DL UNITDATA message
handled at BSSGP level ................................................... 160
Figure 38 - Measurement point of the number of RA-CAPABILITY
message received........................................................... 160
Figure 39 - PTP Packet Paging Process ............................... 160
Figure 40 - PTP Circuit Paging Process ............................... 161
Figure 41 - RA-CAPABILITY-UPDATE Process....................... 161
Figure 42 - RADIO-STATUS Process................................... 162
Figure 43 - FLOW-CONTROL-BVC Process........................... 164
Figure 44 - FLOW-CONTROL-MS Process ............................ 164
Figure 45 - FLOW-CONTROL-PFC Process ........................... 165
Figure 46 - STATUS Process ............................................. 166
Figure 47 - CREATE-BSS-PFC Process ................................ 169
Figure 48 - MODIFY-BSS-PFC Process ................................ 170
Figure 49 - DELETE-BSS-PFC Process ................................ 171

178 Confidential and Proprietary Information of ZTE CORPORATION


Tables

Table 1 – Manual Summary ...................................................i


Table 2 - Typographical Conventions..................................... iii
Table 3 - Mouse Operation Conventions ................................ iii
Table 4 – Usage Explanation of the Hazardous Substances in
ZXG10 iBSC (V6.20.10)....................................................... v
Table 5 - Timeslot measurement counter ...............................1
Table 6 - SDCCH Measurement Counter ............................... 25
Table 7 - TCH/F Measurement Counter................................. 34
Table 8 – TCH/H Measurement counter ................................ 77
Table 9 - Abis port message counting measurement counter . 120
Table 10 - Gb Message Statistics Counter ........................... 157

Confidential and Proprietary Information of ZTE CORPORATION 179


ZXG10 iBSC (V6.20.10) erformance Counter Reference (Volume IV)

This page is intentionally blank.

180 Confidential and Proprietary Information of ZTE CORPORATION


Index

C901240001 ........................3 C901250017 ...................... 28


C901240002 ........................3 C901250018 ...................... 28
C901240003 ........................4 C901250019 ...................... 29
C901240004 ........................4 C901260002 ...................... 38
C901240005 ........................4 C901260005 ...................... 38
C901240006 ........................5 C901260007 ...................... 39
C901240007 ........................5 C901260010 ...................... 39
C901240008 ........................5 C901260011 ...................... 40
C901240009 ........................6 C901260013 ...................... 40
C901240010 ........................6 C901260016 ...................... 41
C901240011 ........................6 C901260017 ...................... 42
C901240012 ........................7 C901260018 ...................... 42
C901240013 ........................7 C901260019 ...................... 43
C901240014 ........................7 C901260021 ...................... 44
C901240015 ........................8 C901260024 ...................... 45
C901240016 ........................8 C901260026 ...................... 45
C901240017 ........................8 C901260032 ...................... 46
C901240018 ........................9 C901260033 ...................... 46
C901240019 ........................9 C901260038 ...................... 47
C901240020 ........................9 C901260044 ...................... 47
C901240021 ...................... 10 C901260045 ...................... 48
C901240022 ...................... 10 C901260050 ...................... 48
C901240023 ...................... 11 C901260056 ...................... 49
C901240024 ...................... 12 C901260057 ...................... 49
C901240025 ...................... 12 C901260062 ...................... 49
C901240026 ...................... 13 C901260065 ...................... 50
C901240027 ...................... 13 C901260067 ...................... 51
C901240028 ...................... 13 C901260068 ...................... 51
C901240029 ...................... 14 C901260070 ...................... 51
C901240030 ...................... 14 C901260073 ...................... 52
C901240031 ...................... 15 C901260075 ...................... 52
C901240032 ...................... 15 C901260081 ...................... 52
C901240033 ...................... 15 C901260082 ...................... 53
C901240034 ...................... 16 C901260087 ...................... 53
C901240035 ...................... 16 C901260090 ...................... 54
C901240036 ...................... 16 C901260092 ...................... 54
C901240037 ...................... 16 C901260093 ...................... 55
C901240038 ...................... 18 C901260094 ...................... 55
C901240039 ...................... 19 C901260095 ...................... 56
C901240040 ...................... 19 C901260096 ...................... 57
C901240041 ...................... 20 C901260097 ...................... 58
C901240042 ...................... 20 C901260098 ...................... 59
C901240043 ...................... 20 C901260099 ...................... 60
C901240044 ...................... 21 C901260100 ...................... 60
C901250005 ...................... 25 C901260101 ...................... 60
C901250007 ...................... 26 C901260102 ...................... 61
C901250010 ...................... 26 C901260103 ...................... 61
C901250011 ...................... 27 C901260104 ...................... 62
C901250012 ...................... 27 C901260105 ...................... 62
C901250016 ...................... 27 C901260106 ...................... 63

Confidential and Proprietary Information of ZTE CORPORATION 181


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume IV)

C901260107 ...................... 63 C901270073.......................96


C901260108 ...................... 64 C901270075.......................96
C901260109 ...................... 64 C901270076.......................97
C901260110 ...................... 65 C901270081.......................97
C901260111 ...................... 65 C901270082.......................98
C901260112 ...................... 66 C901270087.......................98
C901260113 ...................... 66 C901270090.......................98
C901260114 ...................... 66 C901270092.......................99
C901260115 ...................... 67 C901270093.......................99
C901260116 ...................... 67 C901270094..................... 100
C901260117 ...................... 68 C901270095..................... 100
C901260118 ...................... 68 C901270096..................... 101
C901260119 ...................... 69 C901270097..................... 101
C901260120 ...................... 69 C901270098..................... 101
C901260121 ...................... 69 C901270099..................... 102
C901260122 ...................... 70 C901270100..................... 102
C901260123 ...................... 70 C901270101..................... 103
C901260124 ...................... 71 C901270102..................... 103
C901260125 ...................... 71 C901270103..................... 104
C901260126 ...................... 72 C901270104..................... 104
C901260127 ...................... 72 C901270105..................... 104
C901260128 ...................... 72 C901270106..................... 105
C901260129 ...................... 73 C901270107..................... 105
C901260130 ...................... 73 C901270108..................... 106
C901260131 ...................... 74 C901270109..................... 106
C901260132 ...................... 74 C901270110..................... 107
C901260133 ...................... 75 C901270111..................... 107
C901260134 ...................... 75 C901270112..................... 108
C901260135 ...................... 75 C901270113..................... 108
C901270002 ...................... 81 C901270114..................... 108
C901270005 ...................... 82 C901270115..................... 109
C901270007 ...................... 82 C901270116..................... 109
C901270008 ...................... 83 C901270117..................... 110
C901270010 ...................... 83 C901270118..................... 110
C901270011 ...................... 84 C901270119..................... 111
C901270012 ...................... 84 C901270120..................... 111
C901270013 ...................... 85 C901270121..................... 111
C901270016 ...................... 86 C901270122..................... 112
C901270017 ...................... 86 C901270123..................... 112
C901270018 ...................... 87 C901270124..................... 113
C901270019 ...................... 87 C901270125..................... 113
C901270021 ...................... 87 C901270126..................... 114
C901270024 ...................... 88 C901270127..................... 114
C901270026 ...................... 88 C901270128..................... 115
C901270027 ...................... 89 C901270129..................... 115
C901270032 ...................... 89 C901270130..................... 115
C901270033 ...................... 90 C901270131..................... 116
C901270038 ...................... 90 C901270132..................... 116
C901270039 ...................... 90 C901270133..................... 117
C901270044 ...................... 91 C901270134..................... 117
C901270045 ...................... 91 C901270135..................... 118
C901270050 ...................... 92 C901280001..................... 123
C901270051 ...................... 92 C901280002..................... 123
C901270056 ...................... 93 C901280003..................... 124
C901270057 ...................... 93 C901280004..................... 124
C901270062 ...................... 94 C901280005..................... 124
C901270065 ...................... 94 C901280006..................... 125
C901270067 ...................... 95 C901280007..................... 125
C901270068 ...................... 95 C901280008..................... 125
C901270070 ...................... 95 C901280009..................... 126

182 Confidential and Proprietary Information of ZTE CORPORATION


Index

C901280010 .................... 126 C901280073 .................... 147


C901280011 .................... 126 C901280074 .................... 147
C901280012 .................... 127 C901280075 .................... 147
C901280013 .................... 127 C901280076 .................... 148
C901280014 .................... 127 C901280077 .................... 148
C901280015 .................... 128 C901280078 .................... 148
C901280016 .................... 128 C901280079 .................... 149
C901280017 .................... 128 C901280080 .................... 149
C901280018 .................... 129 C901280081 .................... 149
C901280019 .................... 129 C901280082 .................... 150
C901280020 .................... 130 C901280083 .................... 150
C901280021 .................... 130 C901280084 .................... 150
C901280022 .................... 130 C901280085 .................... 151
C901280023 .................... 131 C901280086 .................... 151
C901280024 .................... 131 C901280087 .................... 151
C901280025 .................... 131 C901280088 .................... 152
C901280026 .................... 132 C901280089 .................... 152
C901280027 .................... 132 C901280090 .................... 152
C901280028 .................... 133 C901280091 .................... 153
C901280029 .................... 133 C901280092 .................... 153
C901280030 .................... 133 C901280093 .................... 153
C901280031 .................... 134 C901280094 .................... 154
C901280032 .................... 134 C901280095 .................... 154
C901280033 .................... 135 C901280096 .................... 154
C901280034 .................... 135 C901280097 .................... 155
C901280035 .................... 135 C901280098 .................... 155
C901280036 .................... 136 C901280099 .................... 155
C901280037 .................... 136 C901280100 .................... 156
C901280038 .................... 136 C901280101 .................... 156
C901280039 .................... 137 C901280102 .................... 156
C901280040 .................... 137 C901290001 .................... 159
C901280041 .................... 137 C901290002 .................... 159
C901280042 .................... 138 C901290003 .................... 160
C901280043 .................... 138 C901290004 .................... 160
C901280044 .................... 138 C901290005 .................... 161
C901280045 .................... 139 C901290006 .................... 161
C901280046 .................... 139 C901290007 .................... 161
C901280047 .................... 139 C901290008 .................... 162
C901280048 .................... 140 C901290009 .................... 162
C901280049 .................... 140 C901290010 .................... 163
C901280050 .................... 140 C901290011 .................... 163
C901280051 .................... 141 C901290012 .................... 163
C901280052 .................... 141 C901290013 .................... 163
C901280053 .................... 141 C901290014 .................... 164
C901280054 .................... 141 C901290015 .................... 164
C901280055 .................... 142 C901290016 .................... 165
C901280056 .................... 142 C901290017 .................... 165
C901280057 .................... 142 C901290018 .................... 165
C901280061 .................... 143 C901290019 .................... 166
C901280062 .................... 143 C901290020 .................... 166
C901280063 .................... 143 C901290021 .................... 166
C901280064 .................... 144 C901290022 .................... 167
C901280065 .................... 144 C901290023 .................... 167
C901280066 .................... 144 C901290024 .................... 167
C901280067 .................... 145 C901290025 .................... 167
C901280068 .................... 145 C901290026 .................... 168
C901280069 .................... 145 C901290027 .................... 168
C901280070 .................... 146 C901290028 .................... 168
C901280071 .................... 146 C901290029 .................... 169
C901280072 .................... 146 C901290030 .................... 169

Confidential and Proprietary Information of ZTE CORPORATION 183


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume IV)

C901290031 .....................169 C901290034..................... 170


C901290032 .....................170 C901290035..................... 171
C901290033 .....................170 C901290036..................... 171

184 Confidential and Proprietary Information of ZTE CORPORATION


ZXG10 iBSC
Base Station Controller
Performance Counter Reference (Volume V)

Version 6.20.10

ZTE CORPORATION
ZTE Plaza, Keji Road South,
Hi-Tech Industrial Park,
Nanshan District, Shenzhen,
P. R. China
518057
Tel: (86) 755 26771900 800-9830-9830
Fax: (86) 755 26772236
URL: http://support.zte.com.cn
E-mail: doc@zte.com.cn
This page is intentionally blank.
Contents

About This Manual ............................................................ i


Purpose ................................................................................ i
Intended Audience ................................................................. i
Prerequisite Skill and Knowledge .............................................. i
What Is in This Manual ........................................................... i
Related Documentation......................................................... iii
Conventions ........................................................................ iv
How to Get in Touch.............................................................. v

Declaration of RoHS Compliance................................... vii

Chapter 1.......................................................................... 1

NSVC Statistic Measurement ........................................... 1


Overview ............................................................................. 1
NSVC Statistic Measurement Counter Index .............................. 1
C901300001 ........................................................................ 3
C901300002 ........................................................................ 3
C901300003 ........................................................................ 4
C901300004 ........................................................................ 4
C901300005 ........................................................................ 4
C901300006 ........................................................................ 5
C901300007 ........................................................................ 5
C901300008 ........................................................................ 5
C901300009 ........................................................................ 6
C901300010 ........................................................................ 6
C901300011 ........................................................................ 7
C901300012 ........................................................................ 7
C901300013 ........................................................................ 7
C901300014 ........................................................................ 8
C901300015 ........................................................................ 8
C901300016 ........................................................................ 8
C901300017 ........................................................................ 9
C901300018........................................................................ 9
C901300019.......................................................................10
C901300020.......................................................................10
C901300021.......................................................................10
C901300022.......................................................................11
C901300023.......................................................................11
C901300024.......................................................................11
C901300025.......................................................................12
C901300026.......................................................................12
C901300027.......................................................................13
C901300028.......................................................................13
C901300029.......................................................................14
C901300030.......................................................................14
C901300031.......................................................................15
C901300032.......................................................................15
C901300033.......................................................................15
C901300034.......................................................................15
C901300035.......................................................................15
C901300036.......................................................................15
C901300037.......................................................................16

Chapter 2........................................................................ 17

NSE Statistic Measurement ...........................................17


Overview ...........................................................................17
NSE Statistic Measurement Counter Index ..............................17
C901310001.......................................................................19
C901310002.......................................................................20
C901310003.......................................................................20
C901310004.......................................................................21
C901310005.......................................................................21
C901310006.......................................................................22
C901310007.......................................................................22
C901310008.......................................................................22
C901310009.......................................................................23
C901310010.......................................................................23
C901310011.......................................................................24
C901310012.......................................................................24
C901310013.......................................................................25
C901310014.......................................................................25
C901310015 ...................................................................... 26
C901310016 ...................................................................... 26
C901310017 ...................................................................... 26
C901310018 ...................................................................... 27
C901310019 ...................................................................... 27
C901310020 ...................................................................... 27
C901310021 ...................................................................... 28
C901310022 ...................................................................... 28
C901310023 ...................................................................... 29
C901310024 ...................................................................... 29
C901310025 ...................................................................... 30
C901310026 ...................................................................... 30
C901310027 ...................................................................... 31
C901310028 ...................................................................... 31
C901310029 ...................................................................... 31
C901310030 ...................................................................... 32
C901310031 ...................................................................... 32
C901310032 ...................................................................... 32
C901310033 ...................................................................... 33
C901310034 ...................................................................... 33
C901310035 ...................................................................... 34
C901310036 ...................................................................... 34
C901310037 ...................................................................... 34
C901310038 ...................................................................... 35
C901310039 ...................................................................... 35
C901310040 ...................................................................... 35
C901310041 ...................................................................... 35
C901310042 ...................................................................... 36
C901310043 ...................................................................... 36
C901310044 ...................................................................... 36
C901310045 ...................................................................... 37
C901310046 ...................................................................... 37
C901310047 ...................................................................... 37
C901310048 ...................................................................... 38
C901310049 ...................................................................... 38
C901310050 ...................................................................... 38

Chapter 3........................................................................ 39

BTS TRX Measurement .................................................. 39


Overview ...........................................................................39
BTS TRX Measurement Counter Index ....................................40
C901320001.......................................................................42
C901320002.......................................................................42
C901320003.......................................................................43
C901320004.......................................................................43
C901320005.......................................................................43
C901320006.......................................................................44
C901320007.......................................................................44
C901320008.......................................................................44
C901320009.......................................................................45
C901320010.......................................................................45
C901320011.......................................................................45
C901320012.......................................................................46
C901320013.......................................................................46
C901320014.......................................................................47
C901320015.......................................................................47
C901320016.......................................................................47
C901320017.......................................................................48
C901320018.......................................................................48
C901320019.......................................................................48
C901320020.......................................................................49
C901320021.......................................................................49
C901320022.......................................................................49
C901320023.......................................................................50
C901320024.......................................................................50
C901320025.......................................................................50
C901320026.......................................................................50
C901320027.......................................................................51
C901320028.......................................................................51
C901320029.......................................................................51
C901320030.......................................................................52
C901320031.......................................................................52
C901320032.......................................................................52
C901320033.......................................................................53
C901320034.......................................................................53
C901320035.......................................................................53
C901320036.......................................................................53
C901320037.......................................................................54
C901320038 ...................................................................... 54
C901320039 ...................................................................... 54
C901320040 ...................................................................... 54
C901320041 ...................................................................... 55
C901320042 ...................................................................... 55
C901320043 ...................................................................... 55
C901320044 ...................................................................... 55

Chapter 4........................................................................ 57

NSVC on IPGB HOST Measurement............................... 57


Overview ........................................................................... 57
NSVC on IPGB HOST Measurement Counter Index ................... 57
C901330001 ...................................................................... 58
C901330002 ...................................................................... 58
C901330003 ...................................................................... 58
C901330004 ...................................................................... 58
C901330005 ...................................................................... 59
C901330006 ...................................................................... 59
C901330007 ...................................................................... 59

Chapter 5........................................................................ 61

GB Message on IPGB HOST Measurement.................... 61


Overview ........................................................................... 61
GB Message on IPGB HOST Measurement Counter Index .......... 61
C901340001 ...................................................................... 63
C901340002 ...................................................................... 63
C901340003 ...................................................................... 64
C901340004 ...................................................................... 64
C901340005 ...................................................................... 65
C901340006 ...................................................................... 65
C901340007 ...................................................................... 65
C901340008 ...................................................................... 66
C901340009 ...................................................................... 66
C901340010 ...................................................................... 66
C901340011 ...................................................................... 67
C901340012 ...................................................................... 67
C901340013 ...................................................................... 68
C901340014 ...................................................................... 68
C901340015 ...................................................................... 68
C901340016.......................................................................69
C901340017.......................................................................69
C901340018.......................................................................69
C901340019.......................................................................70
C901340020.......................................................................70
C901340021.......................................................................70
C901340022.......................................................................70
C901340023.......................................................................71
C901340024.......................................................................71
C901340025.......................................................................71
C901340026.......................................................................71
C901340027.......................................................................72
C901340028.......................................................................72
C901340029.......................................................................72
C901340030.......................................................................73
C901340031.......................................................................73
C901340032.......................................................................73
C901340033.......................................................................74
C901340034.......................................................................74

Chapter 6........................................................................ 75

NSE on IPGB HOST Measurement .................................75


Overview ...........................................................................75
NSE on IPGB HOST Measurement Counter Index......................75
C901350001.......................................................................77
C901350002.......................................................................78
C901350003.......................................................................78
C901350004.......................................................................78
C901350005.......................................................................79
C901350006.......................................................................79
C901350007.......................................................................79
C901350008.......................................................................80
C901350009.......................................................................80
C901350010.......................................................................80
C901350011.......................................................................81
C901350012.......................................................................81
C901350013.......................................................................81
C901350014.......................................................................82
C901350015.......................................................................82
C901350016 ...................................................................... 82
C901350017 ...................................................................... 82
C901350018 ...................................................................... 83
C901350019 ...................................................................... 83
C901350020 ...................................................................... 83
C901350021 ...................................................................... 84
C901350022 ...................................................................... 84
C901350023 ...................................................................... 84
C901350024 ...................................................................... 85
C901350025 ...................................................................... 85
C901350026 ...................................................................... 85
C901350027 ...................................................................... 86
C901350028 ...................................................................... 86
C901350029 ...................................................................... 86
C901350030 ...................................................................... 87
C901350031 ...................................................................... 87
C901350032 ...................................................................... 88
C901350033 ...................................................................... 88
C901350034 ...................................................................... 88
C901350035 ...................................................................... 89
C901350036 ...................................................................... 89
C901350037 ...................................................................... 89
C901350038 ...................................................................... 90
C901350039 ...................................................................... 90
C901350040 ...................................................................... 90
C901350041 ...................................................................... 90
C901350042 ...................................................................... 91
C901350043 ...................................................................... 91
C901350044 ...................................................................... 91
C901350045 ...................................................................... 92
C901350046 ...................................................................... 92
C901350047 ...................................................................... 92
C901350048 ...................................................................... 93
C901350049 ...................................................................... 93
C901350050 ...................................................................... 93

Chapter 7........................................................................ 95

BSSMAP Message Measurement ................................... 95


Overview ........................................................................... 95
BSSMAP Message Measurement Counter Index ........................96
C901360001.......................................................................98
C901360002.......................................................................99
C901360003..................................................................... 100
C901360004..................................................................... 100
C901360005..................................................................... 101
C901360006..................................................................... 101
C901360007..................................................................... 102
C901360008..................................................................... 102
C901360009..................................................................... 103
C901360010..................................................................... 103
C901360011..................................................................... 104
C901360012..................................................................... 104
C901360013..................................................................... 105
C901360014..................................................................... 105
C901360015..................................................................... 106
C901360016..................................................................... 107
C901360017..................................................................... 107
C901360018..................................................................... 108
C901360019..................................................................... 108
C901360020..................................................................... 109
C901360021..................................................................... 109
C901360022..................................................................... 109
C901360023..................................................................... 110
C901360024..................................................................... 110
C901360025..................................................................... 111
C901360026..................................................................... 111
C901360027..................................................................... 112
C901360028..................................................................... 112
C901360029..................................................................... 113
C901360030..................................................................... 113
C901360031..................................................................... 114
C901360032..................................................................... 114
C901360033..................................................................... 115
C901360034..................................................................... 115
C901360035..................................................................... 116
C901360036..................................................................... 116
C901360037..................................................................... 117
C901360038..................................................................... 117
C901360039 .................................................................... 118
C901360040 .................................................................... 118
C901360041 .................................................................... 119
C901360042 .................................................................... 119
C901360043 .................................................................... 120
C901360044 .................................................................... 120
C901360045 .................................................................... 121
C901360046 .................................................................... 121
C901360047 .................................................................... 122
C901360048 .................................................................... 122
C901360049 .................................................................... 123
C901360050 .................................................................... 123
C901360051 .................................................................... 124
C901360052 .................................................................... 124
C901360053 .................................................................... 125
C901360054 .................................................................... 125
C901360055 .................................................................... 126
C901360056 .................................................................... 126
C901360057 .................................................................... 127
C901360058 .................................................................... 127
C901360059 .................................................................... 127
C901360060 .................................................................... 128
C901360061 .................................................................... 128
C901360062 .................................................................... 129
C901360063 .................................................................... 129
C901360064 .................................................................... 130
C901360065 .................................................................... 130
C901360066 .................................................................... 131
C901360067 .................................................................... 131
C901360068 .................................................................... 132
C901360069 .................................................................... 132
C901360070 .................................................................... 133
C901360071 .................................................................... 133
C901360072 .................................................................... 134
C901360073 .................................................................... 134
C901360074 .................................................................... 135
C901360075 .................................................................... 135
C901360076 .................................................................... 136
C901360077 .................................................................... 136
Chapter 8......................................................................137

A-Interface Message Measurement ............................137


Overview ......................................................................... 137
A-Interface Message Measurement Counter Index .................. 137
C901370001..................................................................... 138
C901370002..................................................................... 138
C901370003..................................................................... 139
C901370004..................................................................... 139
C901370005..................................................................... 140
C901370006..................................................................... 140
C901370007..................................................................... 140

Chapter 9......................................................................143

Terrestrial Resource Availability Measurement ..........143


Overview ......................................................................... 143
Terrestrial Resource Availability Measurement Counter Index... 143
C901380001..................................................................... 144
C901380002..................................................................... 144
C901380003..................................................................... 145
C901380004..................................................................... 145
C901380005..................................................................... 145
C901380006..................................................................... 146
C901380007..................................................................... 146
C901380008..................................................................... 146
C901380009..................................................................... 147
C901380010..................................................................... 148
C901380011..................................................................... 148
C901380012..................................................................... 148
C901380013..................................................................... 149
C901380014..................................................................... 149
C901380015..................................................................... 150

Chapter 10....................................................................151

Ater Message Measurement ........................................151


Overview ......................................................................... 151
Ater Message Measurement Counter Index............................ 151
C901390001..................................................................... 153
C901390002..................................................................... 154
C901390003 .................................................................... 154
C901390004 .................................................................... 154
C901390005 .................................................................... 154
C901390006 .................................................................... 155
C901390007 .................................................................... 155
C901390008 .................................................................... 155
C901390009 .................................................................... 155
C901390010 .................................................................... 156
C901390011 .................................................................... 156
C901390012 .................................................................... 156
C901390013 .................................................................... 156
C901390014 .................................................................... 157
C901390015 .................................................................... 157
C901390016 .................................................................... 157
C901390017 .................................................................... 157
C901390018 .................................................................... 158
C901390019 .................................................................... 158
C901390020 .................................................................... 158
C901390021 .................................................................... 158
C901390022 .................................................................... 159
C901390023 .................................................................... 159
C901390024 .................................................................... 159
C901390025 .................................................................... 159
C901390026 .................................................................... 160
C901390027 .................................................................... 160
C901390028 .................................................................... 160
C901390029 .................................................................... 160
C901390030 .................................................................... 161
C901390031 .................................................................... 161
C901390032 .................................................................... 161
C901390033 .................................................................... 161
C901390034 .................................................................... 162
C901390035 .................................................................... 162
C901390036 .................................................................... 162
C901390037 .................................................................... 162
C901390038 .................................................................... 163
C901390039 .................................................................... 163
C901390040 .................................................................... 163
C901390041 .................................................................... 163
C901390042..................................................................... 164
C901390043..................................................................... 164
C901390044..................................................................... 164
C901390045..................................................................... 164
C901390046..................................................................... 165
C901390047..................................................................... 165
C901390048..................................................................... 165
C901390049..................................................................... 165
C901390050..................................................................... 166
C901390051..................................................................... 166
C901390052..................................................................... 166
C901390053..................................................................... 166
C901390054..................................................................... 167
C901390055..................................................................... 167

Chapter 11....................................................................169

MTP2 Signal Link Measurement ..................................169


Overview ......................................................................... 169
MTP2 Signal Link Measurement Counter Index....................... 169
C901400001..................................................................... 170
C901400002..................................................................... 170
C901400003..................................................................... 171
C901400004..................................................................... 171
C901400005..................................................................... 171
C901400006..................................................................... 172
C901400007..................................................................... 172
C901400008..................................................................... 172
C901400009..................................................................... 173
C901400010..................................................................... 173
C901400011..................................................................... 173
C901400012..................................................................... 173
C901400013..................................................................... 174
C901400014..................................................................... 174
C901400015..................................................................... 174
C901400016..................................................................... 175

Chapter 12....................................................................177

CPU/MEM Measurement..............................................177
Overview ......................................................................... 177
CPU/MEM Measurement Counter Index................................. 177
C901410001 .................................................................... 178
C901410002 .................................................................... 178
C901410003 .................................................................... 178
C901410004 .................................................................... 179
C901410005 .................................................................... 179
C901410006 .................................................................... 179
C901410007 .................................................................... 180
C901410008 .................................................................... 180

Chapter 13.................................................................... 181

SCTP AS Measurement ................................................181


Overview ......................................................................... 181
SCTP AS Measurement Counter Index .................................. 181
C901420001 .................................................................... 183
C901420002 .................................................................... 183
C901420003 .................................................................... 184
C901420004 .................................................................... 184
C901420005 .................................................................... 184
C901420006 .................................................................... 184
C901420007 .................................................................... 185
C901420008 .................................................................... 185
C901420009 .................................................................... 185
C901420010 .................................................................... 186
C901420011 .................................................................... 186
C901420012 .................................................................... 186
C901420013 .................................................................... 187
C901420014 .................................................................... 187
C901420015 .................................................................... 187
C901420016 .................................................................... 187
C901420017 .................................................................... 188
C901420018 .................................................................... 188
C901420019 .................................................................... 188
C901420020 .................................................................... 189
C901420021 .................................................................... 189
C901420022 .................................................................... 189
C901420023 .................................................................... 190
C901420024 .................................................................... 190
C901420025 .................................................................... 190
C901420026..................................................................... 191
C901420027..................................................................... 191

Chapter 14....................................................................193

IP Port Performance Statistics ....................................193


Overview ......................................................................... 193
IP Port Performance Statistics Counter Index......................... 193
C901430001..................................................................... 194
C901430002..................................................................... 194
C901430003..................................................................... 194
C901430004..................................................................... 195

Chapter 15....................................................................197

GTRUNK Resource Statistics........................................197


Overview ......................................................................... 197
GTRUNK Resource Statistics Counter Index ........................... 197
C901440001..................................................................... 198
C901440002..................................................................... 198
C901440003..................................................................... 198
C901440004..................................................................... 199

Appendix A ...................................................................201

Abbreviations ...............................................................201

Appendix B ...................................................................205

Figures..........................................................................205

Tables ...........................................................................211

Index ............................................................................213
About This Manual

Purpose
This manual provides procedures and guidelines that support the
operation of the ZXG10 iBSC (V6.20.10).

Intended Audience
This manual is intended for engineers and technicians who
perform operation activities on the ZXG10 iBSC (V6.20.10).

Prerequisite Skill and Knowledge


To use this manual effectively, users should have a general
understanding of wireless telecommunications technology.
Familiarity with the following is helpful:
„ ZXG10 system and its various components
„ GSM BSS components and processes
„ Local operating procedures

What Is in This Manual


This manual contains three volumes, including the following
sections:

TABLE 1 – M ANUAL SUMMARY

Section Summary
Chapter 1, NSVC Introduces the detailed information about
Statistic Measurement counters related to NSVC statistic
measurement.
Chapter 2, NSE Introduces the detailed information about
Statistic Measurement counters related to NSE statistic
measurement.
Chapter 3, BTS TRX Introduces the detailed information about

Confidential and Proprietary Information of ZTE CORPORATION i


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Section Summary
Measurement counters related to BTS TRX
measurement.
Chapter 4, NSVC on Introduces the detailed information about
IPGB HOST counters related to NSVC on IPGB HOST
Measurement measurement.
Chapter 5, GB Message Introduces the detailed information about
on IPGB HOST counters related to GB message on IPGB
Measurement HOST measurement.
Chapter 6, NSE on Introduces the detailed information about
IPGB HOST counters related to NSE on IPGB HOST
Measurement measurement.
Chapter 7, BSSMAP Introduces the detailed information about
Message Measurement counters related to BSSMAP message
measurement.
Chapter 8, A-Interface Introduces the detailed information about
Message Measurement counters related to A-Interface message
measurement.
Chapter 9, Terrestrial Introduces the detailed information about
Resource Availability counters related to terrestrial resource
Measurement availability measurement
Chapter 10, Ater Introduces the detailed information about
Message Measurement counters related to Ater message
measurement
Chapter 11, MTP2 Introduces the detailed information about
Signal Link counters related to MTP2 signal link
Measurement measurement
Chapter 12, CPU/MEM Introduces the detailed information about
Measurement counters related to CPU/MEM
measurement
Chapter 13, SCTP AS Introduces the detailed information about
Measurement counters related to SCTP AS measurement
Chapter 14, IP Port Introduces the detailed information about
Performance Statistics counters related to IP port performance
statistics
Chapter 15, GTRUNK Introduces the detailed information about
Resource Statistics counters related to GTRUNK resource
statistics
Appendix A, Lists all the abbreviations used in this
Abbreviations manual.

Appendix B, Figures Lists all the figures and tables used in this
and Tables manual.

Index Index of terms and definitions appeared in


this manual.

ii Confidential and Proprietary Information of ZTE CORPORATION


About This Manual

Related Documentation
The following documentation is related to this manual:
„ ZXG10 iBSC (V6.20.10) Base Station Controller
Documentation Guide
„ ZXG10 iBSC (V6.20.10) Base Station Controller System
Description
„ ZXG10 iBSC (V6.20.10) Base Station Controller Hardware
Description
„ ZXG10 iBSC (V6.20.10) Base Station Controller Hardware
Installation Guide
„ ZXG10 iBSC (V6.20.10) Base Station Controller Routine
Maintenance
„ ZXG10 iBSC (V6.20.10) Base Station Controller Emergency
Maintenance
„ ZXG10 iBSC (V6.20.10) Base Station Controller
Troubleshooting
„ ZXG10 iBSC (V6.20.10) Base Station Controller KPI
Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem OMM
Software Installation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Initial
Configuration Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Feature
Configuration Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Radio
Parameters Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Ground
Parameters Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem MML
Command Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Signaling
Tracing Operation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Diagnosis
Test Operation Guide
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Alarm
Handling Reference
„ ZXG10 BSS (V6.20.10) Base Station Subsystem Notification
Handling Reference

Confidential and Proprietary Information of ZTE CORPORATION iii


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Conventions
Typographical ZTE documents employ the following typographical conventions.
Conventions
TABLE 2 - TYPOGRAPHIC AL CONVENTIONS

Typeface Meaning
Italics References to other Manuals and documents.
“Quotes” Links on screens.
Bold Menus, menu options, function names, input
fields, radio button names, check boxes, drop-
down lists, dialog box names, window names.
CAPS Keys on the keyboard and buttons on screens
and company name.
Constant width Text that you type, program code, files and
directory names, and function names.
[] Optional parameters.
{} Mandatory parameters.
| Select one of the parameters that are delimited
by it.
Note: Provides additional information about a
certain topic.
Checkpoint: Indicates that a particular step needs
to be checked before proceeding further.
Tip: Indicates a suggestion or hint to make things
easier or more productive for the reader.

Mouse TABLE 3 - MOUSE OPERATION CONVENTIONS


Operation
Conventions Typeface Meaning
Click Refers to clicking the primary mouse button (usually
the left mouse button) once.
Double-click Refers to quickly clicking the primary mouse button
(usually the left mouse button) twice.
Right-click Refers to clicking the secondary mouse button
(usually the right mouse button) once.
Drag Refers to pressing and holding a mouse button and
moving the mouse.

iv Confidential and Proprietary Information of ZTE CORPORATION


About This Manual

How to Get in Touch


The following sections provide information on how to obtain
support for the documentation and the software.
Customer If you have problems, questions, comments, or suggestions
Support regarding your product, contact us by e-mail at
support@zte.com.cn. You can also call our customer support
center at (86) 755 26771900 and (86) 800-9830-9830.
Documentation ZTE welcomes your comments and suggestions on the quality
Support and usefulness of this document. For further questions,
comments, or suggestions on the documentation, you can
contact us by e-mail at doc@zte.com.cn; or you can fax your
comments and suggestions to (86) 755 26772236. You can also
browse our website at http://support.zte.com.cn, which contains
various interesting subjects like documentation, knowledge base,
forum and service request.

Confidential and Proprietary Information of ZTE CORPORATION v


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This page is intentionally blank.

vi Confidential and Proprietary Information of ZTE CORPORATION


Declaration of RoHS
Compliance

To minimize the environmental impact and take more


responsibility to the earth we live, this document shall serve as
formal declaration that the ZXG10 iBSC (V6.20.10) Base Station
Controller manufactured by ZTE CORPORATION is in compliance
with the Directive 2002/95/EC of the European Parliament -
RoHS (Restriction of Hazardous Substances) with respect to the
following substances:
„ Lead (Pb)
„ Mercury (Hg)
„ Cadmium (Cd)
„ Hexavalent Chromium (Cr (VI))
„ PolyBrominated Biphenyls (PBB’s)
„ PolyBrominated Diphenyl Ethers (PBDE’s)
The usage of the above substances in ZXG10 iBSC (V6.20.10) is
explained in the Table 4.

TABLE 4 – USAGE EXPLANATION OF THE HAZ ARDOUS SUBSTANCES IN ZXG10


IBSC (V6.20.10)

Hazardous substances
Names of Parts
Pb Hg Cd Cr(VI) PBB’s PBDE’s

System × 0 0 0 0 0
Cables and Assembly 0 0 0 0 0 0
Auxiliary Equipment × × × × × ×

Table Explanation:
0: The usage of the substance in all of the components is less
than the allowed values given by 2002/95/EC standard.
×: The usage of the substance in at least one of the components
is beyond the allowed values given by 2002/95/EC standard.

Confidential and Proprietary Information of ZTE CORPORATION vii


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

The ZXG10 iBSC (V6.20.10) Base Station Controller


manufactured by ZTE CORPORATION meet the requirements of
EU 2002/95/EC; however, some assemblies are customized to
client specifications. Addition of specialized, customer-specified
materials or processes, which do not meet the requirements of
EU 2002/95 /EC, may negate RoHS compliance of the assembly.
To guarantee compliance of the assembly, the need for
compliant product must be communicated to ZTE CORPORATION
in written form.
This declaration is issued based on our current level of
knowledge. Since conditions of use are outside our control, ZTE
CORPORATION makes no warranties, express or implied, and
assumes no liability in connection with the use of this
information.

viii Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1

NSVC Statistic
Measurement

The NSVC statistic measurement takes NSVC as the


measurement entity. It performs statistics for data transmission,
signaling interaction, and link transceiving abnormality for NSVC
link. This chapter introduces the meaning, usage, and
measurement point of NSVC statistic counters.

Overview
The NSVC statistic measurement is used to measure signaling
interaction and data transmission at NS layer of Gb interface for
GPRS service. It counts the number of various messages, such
as blocking, unblocking, resetting, and ALIVE.
Statistic unit in this measurement is NSVC.

NSVC Statistic Measurement


Counter Index
Table 5 lists counters related to NSVC statistic measurement.

TABLE 5 – NSVC STATISTIC MEASUREMENT COUNTERS

Counter ID What It Counts


C901300001 Time of PVC unavailable
C901300002 Time of PVC congestion frame relay
C901300003 Time of PVC congestion of level 1
C901300004 Number of bytes received from SGSN
C901300005 Number of bytes sent to SGSN
C901300006 Number of PDU data sent by NS sub layer

Confidential and Proprietary Information of ZTE CORPORATION 1


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Counter ID What It Counts


C901300007 Number of PDU data received by NS sub layer
C901300008 Number of PDU data discarded by NS sub layer
C901300009 Number of reset messages send to opposite end by
NS sub layer
C901300010 Number of received reset messages sent by
opposite end
C901300011 Number of reset confirm messages send to
opposite end by NS sub layer
C901300012 Number of received reset confirm messages sent
by opposite end
C901300013 Number of blocking messages send to opposite end
by NS sub layer
C901300014 Number of received blocking messages sent by
opposite end
C901300015 Number of blocking confirm messages send to
opposite end by NS sub layer
C901300016 Number of received blocking confirm messages
sent by opposite end
C901300017 Number of unblocking messages send to opposite
end by NS sub layer
C901300018 Number of received unblocking messages sent by
opposite end
C901300019 Number of unblocking confirm messages send to
opposite end by NS sub layer
C901300020 Number of received unblocking acknowledge
messages replied by opposite end
C901300021 Number of abnormal cases in NS transmission due
to network fault
C901300022 Number of abnormal cases in NS transmission due
to O&M interference
C901300023 Number of abnormal cases in NS transmission due
to equipment fault
C901300024 Number of abnormal cases in NS transmission due
to NSVC block
C901300025 Number of abnormal cases in NS transmission due
to unknown NSVC
C901300026 Number of abnormal cases in NS transmission due
to protocol error
C901300027 Number of test failure (while over max)
C901300028 Number of blocking procedure failure (after
exceeding the maximum times)
C901300029 Number of unblocking procedure failure (after
exceeding the maximum times)
C901300030 Number of congestion occurrence of level 1

2 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - NSVC Statistic Measurement

Counter ID What It Counts


C901300031 Number of congestion recovery of level 1
C901300032 Number of congestion occurrence of level 2
C901300033 Number of congestion recovery of level 2
C901300034 Number of congestion occurrence of level 3
C901300035 Number of congestion recovery of level 3
C901300036 Number of BECN
C901300037 Number of FECN

C901300001
Definition Time of PVC unavailable
Description This counter counts the time during which NSVC can not be used
for data transmission.
Measurement The counter starts counting when NSVC link becomes abnormal
Point and stops counting when NSVC link becomes normal. The
duration between the two time points is the time during which
NSVC is unavailable, which is T shown in Figure 1.

FIGURE 1 – TIME OF PVC UNAV AIL ABLE

Unit Second

C901300002
Definition Time of PVC congestion frame relay
Description The time during which BECN in the data sent by SGSN is set is
the total time of PVC congestion bit being set. The counter
counts the total time of PVC congestion bit being set.
Measurement The counter starts counting when SGSN receives data in which
Point BECN is set and stops counting when BECN is not set. The
duration between the two time points is the total time of PVC
congestion bit being set, which is T shown in Figure 2.

Confidential and Proprietary Information of ZTE CORPORATION 3


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

FIGURE 2 – TIME OF PVC CONGESTION FRAME RELAY

Unit Second

C901300003
Definition Time of PVC congestion of level 1
Description This counter is not used.

C901300004
Definition Number of bytes received from SGSN
Description This counter counts the number of bytes received by NS sub
layer from SGSN.
Usage The NSVC load can be checked through this counter.
Measurement FR accumulates the number of bytes received from Gb interface.
Point The measurement point is A1, as shown in Figure 3.

FIGURE 3 – UPLINK/DOWNLINK NS DATA

Unit Byte

C901300005
Definition Number of bytes sent to SGSN
Description This counter counts the number of bytes sent to SGSN from NS
sub layer.
Usage The NSVC load can be checked through this counter.

4 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - NSVC Statistic Measurement

Measurement FR accumulates the number of bytes sent each time. The


Point measurement point is A2, as shown in Figure 3.
Unit Byte

C901300006
Definition Number of PDU data sent by NS sub layer
Description This counter counts the number of PDU data sent to SGSN from
NS sub layer.
Usage The NSVC service load can be checked through this counter.
Measurement The counter increments each time BSC's FR sends a PDU data to
Point SGSN. The measurement point is A1, as shown in Figure 4.

FIGURE 4 – SENDING AND RECEIVING PDU DAT A

Unit Times

C901300007
Definition Number of PDU data received by NS sub layer
Description This counter counts the number of PDU data received by NS sub
layer from SGSN.
Usage The NSVC service load can be checked through this counter.
Measurement The counter increments each time BSC's FR receives a PDU data
Point from SGSN. The measurement point is A2, as shown in Figure 4.
Unit Times

C901300008
Definition Number of PDU data discarded by NS sub layer
Description The amount of PDU data discarded by NS sub layer is the sum of
incorrect PDU data received by NS sub layer from SGSN and
PDU data that FR fails to send.
Measurement „ The counter increments when NS sub layer receives an illegal
Point PDU data, as shown in Figure 5.

Confidential and Proprietary Information of ZTE CORPORATION 5


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

„ The counter increments when FR fails to send a PDU data, as


shown in Figure 5.

FIGURE 5 – PDU DAT A DISCARDED BY NS SUB LAYER

Unit Times

C901300009
Definition Number of reset messages send to opposite end by NS sub layer
Description NS sub layer sends the NSVC resetting message to indicate
SGSN to reset specified NSVC. This counter counts the number
of resetting messages sent to opposite end by NS sub layer.
Usage The counter counts the number of BSC resetting specified NSVC.
Measurement Each time BSC sends the “NS-RESET” message, this counter
Point increments. The measurement point is A1, as shown in Figure 6.

FIGURE 6 – NSVC RESETTING PROCESS

BSC SGSN
NS-RESET

A1 NS-RESET-ACK

A2 NS-RESET

A3 NS-RESET-ACK

A4

Unit Times

C901300010
Definition Number of received reset messages sent by opposite end
Description SGSN sends the NSVC resetting message to indicate BSC to
reset specified NSVC. This counter counts the number of
resetting messages received by BSC from the opposite end.

6 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - NSVC Statistic Measurement

Usage The counter counts the number of SGSN resetting specified


NSVC.
Measurement Each time BSC receives the “NS-RESET” message, this counter
Point increments. The measurement point is A3, as shown in Figure 6.
Unit Times

C901300011
Definition Number of reset confirm messages send to opposite end by NS
sub layer
Description NS sub layer sends NSVC reset confirmation message to notify
SGSN that specified NSVC is reset. This counter counts the
number of sending this message by BSC.
Measurement Each time BSC sends the “NS-RESET-ACK” message, this
Point counter increments. The measurement point is A4, as shown in
Figure 6.
Unit Times

C901300012
Definition Number of received reset confirm messages sent by opposite
end
Description SGSN sends NSVC reset confirmation message to notify BSC
that specified NSVC is reset. This counter counts the number of
BSC's receiving this message.
Measurement Each time BSC receives the “NS-RESET-ACK” message, this
Point counter increments. The measurement point is A2, as shown in
Figure 6.
Unit Times

C901300013
Definition Number of blocking messages send to opposite end by NS sub
layer
Description BSC's NS sub layer sends the NSVC blocking message to indicate
SGSN to block specified NSVC. This counter counts the number
of BSC's blocking specified NSVC.
Measurement Each time BSC sends the “NS-BLOCK” message, this counter
Point increments. The measurement point is A1, as shown in Figure 7.

Confidential and Proprietary Information of ZTE CORPORATION 7


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

FIGURE 7 – NSVC BLOCKING PROCESS

Unit Times

C901300014
Definition Number of received blocking messages sent by opposite end
Description SGSN sends the NSVC blocking message to indicate BSC to
block specified NSVC. This counter counts the number of SGSN's
blocking specified NSVC.
Measurement Each time BSC receives the “NS-BLOCK” message, this counter
Point increments. The measurement point is A3, as shown in Figure 7.
Unit Times

C901300015
Definition Number of blocking confirm messages send to opposite end by
NS sub layer
Description BSC's NS sub layer sends NSVC blocking confirmation message
to notify SGSN that specified NSVC is blocked. This counter
counts the number of sending this message by BSC.
Measurement Each time BSC sends the “NS-BLOCK-ACK” message, this
Point counter increments. The measurement point is A4, as shown in
Figure 7.
Unit Times

C901300016
Definition Number of received blocking confirm messages sent by opposite
end
Description

8 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - NSVC Statistic Measurement

SGSN sends NSVC blocking confirmation message to notify BSC


that specified NSVC is reset. This counter counts the number of
BSC's receiving this message.
Measurement Each time BSC receives the “NS-BLOCK-ACK” message, this
Point counter increments. The measurement point is A2, as shown in
Figure 7.
Unit Times

C901300017
Definition Number of unblocking messages send to opposite end by NS sub
layer
Description BSC's NS sub layer sends the NSVC unblocking message to
indicate SGSN to unblock specified NSVC. This counter counts
the number of BSC's unblocking specified NSVC.
Measurement Each time BSC sends the “NS-UNBLOCK” message, this counter
Point increments. The measurement point is A1, as shown in Figure 8.

FIGURE 8 – NSVC UNBLOCKING PROCESS

Unit Times

C901300018
Definition Number of received unblocking messages sent by opposite end
Description SGSN sends the NSVC unblocking message to indicate BSC to
unblock specified NSVC. This counter counts the number of
SGSN's unblocking specified NSVC.
Measurement Each time BSC receives the “NS-UNBLOCK” message, this
Point counter increments. The measurement point is A3, as shown in
Figure 8.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 9


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901300019
Definition Number of unblocking confirm messages send to opposite end
by NS sub layer
Description NS sub layer sends NSVC unblocking confirmation message to
notify SGSN that specified NSVC is unblocked. This counter
counts the number of sending this message by BSC.
Measurement Each time BSC sends the “NS-UNBLOCK-ACK” message, this
Point counter increments. The measurement point is A4, as shown in
Figure 8.
Unit Times

C901300020
Definition Number of received unblocking acknowledge messages replied
by opposite end
Description SGSN sends NSVC unblocking confirmation message to notify
BSC that specified NSVC is unblocked. This counter counts the
number of BSC's receiving this message.
Measurement Each time BSC receives the “NS-UNBLOCK-ACK” message, this
Point counter increments. The measurement point is A2, as shown in
Figure 8.
Unit Times

C901300021
Definition Number of abnormal cases in NS transmission due to network
fault
Description This counter counts the number of abnormal cases in NS sub
layer transmission due to transmission network fault.
Measurement When NS sub layer receives reported fault from frame relay and
Point the fault is due to transmission network fault, the counter
increments. The measurement point is A1, as shown in Figure 9.

FIGURE 9 – FR REPORTING TRANSMISSION NETWORK FAULT

Unit Times

10 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - NSVC Statistic Measurement

C901300022
Definition Number of abnormal cases in NS transmission due to O&M
interference
Description This counter counts the number of abnormal cases in NS sub
layer transmission due to O&M interference.
Measurement When NS sub layer receives the blocking request from
Point background, the counter increments. The measurement point is
A1, as shown in Figure 10.

FIGURE 10 – BLOCKING NSVC BY BACKGROUND

Unit Times

C901300023
Definition Number of abnormal cases in NS transmission due to equipment
fault
Description This counter counts the number of abnormal cases in NS sub
layer transmission due to equipment fault.
Measurement When NS sub layer receives reported fault from frame relay and
Point the fault is due to equipment fault, the counter increments. The
measurement point is A1, as shown in Figure 11.

FIGURE 11 – FR REPORTING EQUIPMENT FAULT

Unit Times

C901300024
Definition Number of abnormal cases in NS transmission due to NSVC
block
Description This counter counts the number of abnormal cases in NS sub
layer transmission due to NSVC block.

Confidential and Proprietary Information of ZTE CORPORATION 11


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Measurement When NS sub layer sends the status message which is due to
Point NSVC BLOCKED, the counter increments. The measurement
point is A1, as shown in Figure 12.

FIGURE 12 – NSVC BLOCKED

Unit Times

C901300025
Definition Number of abnormal cases in NS transmission due to unknown
NSVC
Description This counter counts the number of abnormal cases in NS sub
layer transmission due to unknown NSVC.
Measurement When NS sub layer sends the status message which is due to
Point unknown NSVC, the counter increments. The measurement point
is A1, as shown in Figure 13.

FIGURE 13 – NSVC UNKNOWN

Unit Times

C901300026
Definition Number of abnormal cases in NS transmission due to protocol
error
Description This counter counts the number of abnormal cases in NS sub
layer transmission due to protocol error.
Measurement When NS sub layer sends the status message which is due to
Point protocol error, including PDU semantic error, PDU being
incompatible with protocol, protocol error, invalid necessary IE,
and missing necessary IE, the counter increments. The
measurement point is A1, as shown in Figure 14.

12 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - NSVC Statistic Measurement

FIGURE 14 – NS PROTOCOL ERROR

Unit Times

C901300027
Definition Number of test failure (while over max)
Description This counters counts the number of test failure due to the
maximum retransmission times being exceeded during the NS
sub layer test procedure.
Measurement When the number of NS sub layer's sending NS-ALIVE PDU
Point exceeds the maximum retransmission times NS-ALIVE-RETRIES
and there is no response, the counter increments. The
measurement point is A1, as shown in Figure 15.

FIGURE 15 – TEST PROCEDURE BEING ABNORMAL

Unit Times

C901300028
Definition Number of blocking procedure failure (after exceeding the
maximum times)
Description This counters counts the number of test failure due to the
maximum retransmission times being exceeded during the NS
sub layer blocking procedure.
Measurement When the number of NS sub layer's sending NS-BLOCK PDU
Point exceeds the maximum retransmission times NS-BLOCK-RETRIES
and there is no response, the counter increments. The
measurement point is A1, as shown in Figure 16.

Confidential and Proprietary Information of ZTE CORPORATION 13


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

FI G U R E 1 6 – B L O C K I N G P RO C E D U R E B E IN G AB N O R M AL

BSC SGSN
NS-BLOCK

Tns-block
NS-BLOCK
. NS-BLOCK-
. RETRIES

Tns-block
.
NS-BLOCK
A1

Unit Times

C901300029
Definition Number of unblocking procedure failure (after exceeding the
maximum times)
Description This counters counts the number of test failure due to the
maximum retransmission times being exceeded during the NS
sub layer unblocking procedure.
Measurement When the number of NS sub layer's sending NS-UNBLOCK PDU
Point exceeds the maximum retransmission times NS-UNBLOCK-
RETRIES and there is no response, the counter increments. The
measurement point is A1, as shown in Figure 17.

FIGURE 17 – UNBLOCKING PROCEDURE BEING ABNORMAL

Unit Times

C901300030
Definition Number of congestion occurrence of level 1

14 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - NSVC Statistic Measurement

Description This counter is not used.

C901300031
Definition Number of congestion recovery of level 1
Description This counter is not used.

C901300032
Definition Number of congestion occurrence of level 2
Description This counter is not used.

C901300033
Definition Number of congestion recovery of level 2
Description This counter is not used.

C901300034
Definition Number of congestion occurrence of level 3
Description This counter is not used.

C901300035
Definition Number of congestion recovery of level 3
Description This counter is not used.

C901300036
Definition Number of BECN
Description This counter counts the number of setting BECN in the data sent
by SGSN.
Usage The counter counts the number of NSVC backward congestions.
Measurement When BECN in the data received by FR from SGSN is set, the
Point counter accumulates. The measurement point is A1, as shown in
Figure 18.

Confidential and Proprietary Information of ZTE CORPORATION 15


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

FIGURE 18 – UPLINK/DOWNLINK DAT A BECN BEING SET

Unit Times

C901300037
Definition Number of FECN
Description This counter counts the number of setting FECN in the data sent
by SGSN.
Usage The counter counts the number of NSVC forward congestions.
Measurement When FECN in the data received by FR from SGSN is set, the
Point counter accumulates. The measurement point is A2, as shown in
Figure 18.
Unit Times

16 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2

NSE Statistic
Measurement

The NSE statistic measurement takes a single NSE as the


measurement unit. It performs statistics for paging message,
status indication message, and signaling BVC resetting message,
etc. This chapter introduces the meaning, usage, and
measurement point of NSE statistic counters.

Overview
The NSE statistic measurement takes a single NSE as the
measurement entity. It performs statistics for paging message,
status indication message, and signaling BVC resetting message
received by NSE at BSS.
Statistic unit in this measurement is the single NSE.

NSE Statistic Measurement Counter


Index
Table 6 lists counters related to NSVC statistic measurement.

TABLE 6 – NSE STATISTIC MEASUREMENT COUNTERS

Counter ID What It Counts


C901310001 Number of CS Paging received by BSS
C901310002 Number of PS Paging received by BSS
C901310003 Number of SUSPEND message sent
C901310004 Number of SUSPEND-ACK message received
C901310005 Number of SUSPEND-NACK message received
C901310006 Number of RESUME message sent

Confidential and Proprietary Information of ZTE CORPORATION 17


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Counter ID What It Counts


C901310007 Number of RESUME-ACK message received
C901310008 Number of RESUME-NACK message received
C901310009 Number of FLUSH-LL message received
C901310010 Number of FLUSH-LL-ACK message sent
C901310011 Number of LLC-DISCARDED message sent
C901310012 Number of BVC-BLOCK message sent
C901310013 Number of BVC_BLOCK_ACK message received
C901310014 Number of BVC-UNBLOCK message sent
C901310015 Number of BVC-UNBLOCK-ACK message received
C901310016 Number of BVC-RESET message sent
C901310017 Number of BVC-RESET message received
C901310018 Number of BVC-RESET-ACK message sent
C901310019 Number of BVC-RESET-ACK message received
Number of PERFORM_LOCATION_REQUEST
C901310020
message received
Number of PERFORM-LOCATION-RESPONSE
C901310021
message sent
Number of PERFORM-LOCATION-ABORT message
C901310022
received
C901310023 Number of POSITION-COMMAND message sent
C901310024 Number of POSITION-RESPONSE message received
C901310025 Number of status messages sent
C901310026 Number of status messages received
Number of status messages sent with BVCI
C901310027
Unknown
Number of status messages sent with cell service
C901310028
congestion
Number of status messages sent with protocol
C901310029
error
Number of status messages sent with processor
C901310030
overload
Number of status messages sent with semantically
C901310031
incorrect PDU
Number of status messages sent with invalid
C901310032
mandatory information element
Number of status messages sent with missing
C901310033
mandatory IE
Number of status messages sent with missing
C901310034
conditional IE
Number of status messages sent with unexpected
C901310035
conditional IE

18 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - NSE Statistic Measurement

Counter ID What It Counts


Number of status messages sent with conditional
C901310036
IE error
Number of status messages sent with protocol
C901310037
status incompatible error
Number of status messages received with BVCI
C901310038
unknown
Number of status messages received with cell
C901310039
service congestion
Number of status messages received with protocol
C901310040
error
Number of status messages received with
C901310041
processor overload
Number of status messages received with BVC
C901310042
blocking
Number of status messages received with
C901310043
semantically incorrect PDU
Number of status messages received with invalid
C901310044
mandatory IE
Number of status messages received with missing
C901310045
mandatory IE
Number of status messages received with missing
C901310046
conditional IE
Number of status messages received with
C901310047
unexpected conditional IE
Number of status messages received with
C901310048
conditional IE error
Number of status messages received with protocol
C901310049
status incompatible error
Number of status messages received with SGSN
C901310050
congestion

C901310001
Definition Number of CS Paging received by BSS
Description This counter counts the number of PAGING CS messages
received by NSE at BSC from SGSN.
Usage The counter is used to find out the frequency of SGSN's CS
paging to MS.
Measurement When BSS receives a message of which the type is
Point GB_PAGING_CS, the counter increments. The measurement
point is A, as shown in Figure 19.

Confidential and Proprietary Information of ZTE CORPORATION 19


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

FIGURE 19 – MEASUREMENT POINT OF BSS RECEIVING CS P AGING MESSAGE

Unit Times

C901310002
Definition Number of PS Paging received by BSS
Description This counter counts the number of PAGING PS messages
received by NSE at BSC from SGSN.
Usage The counter is used to find out the frequency of SGSN's PS
paging to MS.
Measurement When BSS receives a message of which the type is
Point GB_PAGING_PS, the counter increments. The measurement
point is A, as shown in Figure 20.

FIGURE 20 – MEASUREMENT POINT OF BSS RECEIVING PS P AGING MESSAGE

Unit Times

C901310003
Definition Number of SUSPEND message sent
Description When BSS receives the suspending GPRS service message from
MS, BSS will send the SUSPEND message to SGSN. This counter
counts the number of sending SUSPEND message from NSE.
Usage The counter is used to find out the frequency of MS's terminating
GPRS service.
Measurement When BSS sends the SUSPEND message, the counter increments.
Point The measurement point is A1, as shown in Figure 21.

20 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - NSE Statistic Measurement

FIGURE 21 – SUSPEND PROCESS

Unit Times

C901310004
Definition Number of SUSPEND-ACK message received
Description When SGSN receives the SUSPEND message from BSS, SGSN
will send the SUSPEND_ACK message to BSS. This counter
counts the number of SUSPEND_ACK messages received by NSE.
Usage The counter is used to find out cases in which SGSN has
response when MS requests for terminating GPRS service.
Measurement When BSS receives the SUSPEND_ACK message, the counter
Point increments. The measurement point is A2, as shown in Figure 21.
Unit Times

C901310005
Definition Number of SUSPEND-NACK message received
Description When SGSN receives the SUSPEND message from BSS, it checks
the SUSPEND message content. If the message content is
incorrect or fault occurs at SGSN, SGSN will send the
SUSPEND_NACK message to BSS. This counter counts the
number of SUSPEND_NACK messages received by NSE.
Usage The counter is used to find out cases in which SGSN has no
response when MS requests for terminating GPRS service.
Measurement When BSS receives the SUSPEND_NACK message, the counter
Point increments. The measurement point is A2, as shown in Figure 22.

FIGURE 22 – MEASUREMENT POINT OF BSS RECEIVING SUSPEND_NACK


MESSAGE

Confidential and Proprietary Information of ZTE CORPORATION 21


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Unit Times

C901310006
Definition Number of RESUME message sent
Description When problems that cause MS to suspend disappear, BSS might
send the RESUME message to SGSN to notify it to resume GPRS
service of MS. This counter counts the number of sending
RESUME message by BSS.
Usage The counter is used to find out the frequency of MS's resuming
GPRS service.
Measurement When BSS sends the RESUME message, the counter increments.
Point The measurement point is A1, as shown in Figure 23.

FIGURE 23 – RESUME PROCESS

Unit Times

C901310007
Definition Number of RESUME-ACK message received
Description When SGSN receives the RESUME message from BSS, SGSN will
send the RESUME_ACK message to BSS. This counter counts the
number of RESUME_ACK messages received by NSE.
Usage The counter is used to find out causes due to which SGSN has
no response when MS requests for resuming GPRS service.
Measurement When BSS receives the RESUME_ACK message, the counter
Point increments. The measurement point is A2, as shown in Figure 23.
Unit Times

C901310008
Definition Number of RESUME-NACK message received
Description If the MS in the RESUME PDU message sent from BSS is not
found at SGSN, SGSN willl send the RESUME_NACK message to
BSS. This message contains the failure cause, that is, unknown

22 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - NSE Statistic Measurement

MS. At this moment, BSS will terminate the RESUME process


and ask MS to update routing area. This counter counts the
number of RESUME_NACK messages received by NSE.
Usage The counter is used to find out cases in which SGSN has no
response when MS requests for resuming GPRS service.
Measurement When BSS receives the RESUME_NACK message, the counter
Point increments. The measurement point is A2, as shown in Figure 24.

FIGURE 24 – MEASUREMENT POINT OF BSS RECEIVING RESUME_NACK


MESSAGE

Unit Times

C901310009
Definition Number of FLUSH-LL message received
Description When SGSN detects that a MS changes cell through cell update
or routing area update, SGSN will send the FLUSH_LL message
to the old BVC to initiate the cell update process on NSE. This
counter counts the number of FLUSH_LL messages received by
NSE.
Usage The counter is used to find out the frequency of MS's changing
cell.
Measurement When BSS receives the FLUSH_LL message, the counter
Point increments. The measurement point is A1, as shown in Figure 25.

FIGURE 25 – FLUSH_LL PROCESS

Unit Times

C901310010
Definition Number of FLUSH-LL-ACK message sent

Confidential and Proprietary Information of ZTE CORPORATION 23


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Description When BSS receives the FLUSH_LL message from SGSN, BSS will
send the FLUSH_LL_ACK message to SGSN. This counter counts
the number of sending FLUSH_LL_ACK message from NSE.
Usage The counter is used to find out that, after MS changes cell,
whether the MS's LLC PDU buffer is deleted in the old cell or
moved to the new cell in the routing area.
Measurement When BSS sends the FLUSH_LL_ACK message, the counter
Point increments. The measurement point is A2, as shown in Figure 25.
Unit Times

C901310011
Definition Number of LLC-DISCARDED message sent
Description When the LLC PDU stored in BSS is deleted, the
LLC_DISCARDED message is sent to SGSN. This counter counts
the number of sending LLC_DISCARDED message from NSE.
Usage The counter is used to find out the storage of LLC PDU in BSS.
Measurement When BSS sends the LLC_DISCARDED message, the counter
Point increments. The measurement point is A, as shown in Figure 26.

FIGURE 26 – MEASUREMENT POINT OF BSS SENDING LLC_DISCARDED


MESSAGE

BSC SGSN

LLC_DISCARDED

Unit Times

C901310012
Definition Number of BVC-BLOCK message sent
Description When BSS blocks a BVC, it will send the BVC_BLOCK message to
SGSN to start the timer T1. BSS will identify the blocked BVC
and stop sending uplink data of the BVC. Meanwhile, cells
associated with the BVC do not receive downlink data any more.
This counter counts the number of sending BVC_BLOCK message
from NSE.
Usage The counter is used to find out the frequency of BSS's
requesting to block BVC.
Measurement When BSS sends the BVC_BLOCK message, the counter
Point increments. The measurement point is A1, as shown in Figure 27.

24 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - NSE Statistic Measurement

FIGURE 27 – BVC_BLOCK PROCESS

Unit Times

C901310013
Definition Number of BVC_BLOCK_ACK message received
Description When SGSN receives the BVC_BLOCK message from BSS, it
identifies the BVC to be blocked and stops sending data to the
BVC, and replies the BVC_BLOCK_ACK message to BSS. This
counter counts the number of BVC_BLOCK_ACK messages
received by NSE.
Usage The counter is used to find out cases when BVC is blocked.
Measurement When BSS receives the BVC_BLOCK_ACK message, the counter
Point increments. The measurement point is A2, as shown in Figure 27.
Unit Times

C901310014
Definition Number of BVC-UNBLOCK message sent
Description When BSS unblocks the blocked BVC, it will send the
BVC_UNBLOCK message to SGSN. This counter counts the
number of sending BVC_UNBLOCK message from NSE.
Usage The counter is used to find out the frequency of BSS's
requesting to unblock BVC.
Measurement When BSS sends the BVC_UNBLOCK message, the counter
Point increments. The measurement point is A1, as shown in Figure 28.

FIGURE 28 – BVC_UNBLOCK PROCESS

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 25


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901310015
Definition Number of BVC-UNBLOCK-ACK message received
Description When SGSN receives the BVC_UNBLOCK message from BSS, it
identifies the BVC to be unblocked and replies the
BVC_UNBLOCK_ACK message to BSS. This counter counts the
number of BVC_UNBLOCK_ACK messages received by NSE.
Usage The counter is used to find out cases when BVC is unblocked.
Measurement When BSS receives the BVC_UNBLOCK_ACK message, the
Point counter increments. The measurement point is A2, as shown in
Figure 28.
Unit Times

C901310016
Definition Number of BVC-RESET message sent
Description This counter counts the number of PCU sending signaling BVC
resetting message through Gb interface.
Usage The counter is used to find out the frequency of requesting to
restart BVC due to BVC failure.
Measurement When NSE at BSC sends message of which the type is
Point BVC_RESET and BVCI is zero, the counter increments. The
measurement point is A1, as shown in Figure 29.

FIGURE 29 – PROCESS OF SENDING BVC_RESET

Unit Times

C901310017
Definition Number of BVC-RESET message received
Description This counter counts the number of PCU's receiving the signaling
BVC resetting message.
Usage The counter is used to find out cases when BVC is restarted.

26 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - NSE Statistic Measurement

Measurement When NSE at BSC receives message of which the type is


Point BVC_RESET and BVCI is zero, the counter increments. The
measurement point is A1, as shown in Figure 30.

FIGURE 30 – PROCESS OF RECEIVING BVC_RESET

BSC SGSN
BVC_RESET
A1
BVC_RESET_ACK
A2

Unit Times

C901310018
Definition Number of BVC-RESET-ACK message sent
Description When PCU receives the signaling BVC resetting message from
Gb interface, it replies the signaling BVC resetting acknowledge
message. This counter counts the number of NSE's sending
signaling BVC resetting acknowledge message.
Usage The counter is used to find out cases of SGSN initializing BVC.
Measurement When NSE at BSC sends message of which the type is
Point BVC_RESET_ACK and BVCI is zero, the counter increments. The
measurement point is A2, as shown in Figure 30.
Unit Times

C901310019
Definition Number of BVC_RESET_ACK message received
Description Number of PCU's receiving the signaling BVC resetting
acknowledge message. This counter counts the number of NSE's
receiving signaling BVC resetting acknowledge message.
Usage The counter is used to find out cases of BVC initialization.
Measurement When NSE at BSC receives message of which the type is
Point BVC_RESET_ACK and BVCI is zero, the counter increments. The
measurement point is A2, as shown in Figure 29.
Unit Times

C901310020
Definition Number of PERFORM_LOCATION_REQUEST message received

Confidential and Proprietary Information of ZTE CORPORATION 27


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Description When SGSN receives the location request and BSS supports LCS,
SGSN will start the locating process and send
PERFORM_LOCATION_REQUEST message to BSS. This counter
counts the number of BSS's receiving the location request
message.
Usage The counter is used to find out the frequency of SGSN's sending
location request to BSS.
Measurement When BSS receives the PERFORM_LOCATION_REQUEST
Point message, the counter increments. The measurement point is A1,
as shown in Figure 31.

FIGURE 31 – PERFORM_LOC ATION_REQUEST PROCESS

Unit Times

C901310021
Definition Number of PERFORM_LOCATION_RESPONSE message sent
Description After BSS receives the PERFORM_LOCATION_REQUEST message,
it will send the location request to SMLC and wait for SMLC's
response, and then send the result in the
PERFORM_LOCATION_RESPONSE message to SGSN. This
counter counts the number of BSS's sending the location request
response message.
Usage The counter is used to find out BSS's response to the location
request from SGSN.
Measurement When BSS sends the PERFORM_LOCATION_RESPONSE message,
Point the counter increments. The measurement point is A2, as shown
in Figure 31.
Unit Times

C901310022
Definition Number of PERFORM_LOCATION_ABORT message received
Description When SGSN initiates the location request before interruption
occurs, it sends the PERFORM_LOCATION_ABORT message to
BSS. This counter counts the number of BSS's receiving the
PERFORM_LOCATION_ABORT message.

28 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - NSE Statistic Measurement

Usage The counter is used to find out the frequency of SGSN's


terminating location towards BSS.
Measurement When BSS receives the PERFORM_LOCATION_ABORT message,
Point the counter increments. The measurement point is A, as shown
in Figure 32.

FIGURE 32 – MEASUREMENT POINT OF BSS RECEIVING


PERFORM_LOC ATION_ ABORT MESSAGE

Unit Times

C901310023
Definition Number of POSITION_COMMAND message sent
Description BSS triggers the positioning command process by sending
POSITION_COMMAND message to SGSN. This process is valid
only when positioning a MS. This counter counts the number of
BSS's sending POSITION_COMMAND message.
Usage The counter is used to find out the frequency of BSS's
requesting to implement positioning command to SGSN.
Measurement When BSS sends the POSITION_COMMAND message, the
Point counter increments. The measurement point is A1, as shown in
Figure 33.

FIGURE 33 – POSITION_COMM AND PROCESS

Unit Times

C901310024
Definition Number of POSITION_RESPONSE message received
Description When SGSN receives the TOM message, SGSN will send the
POSITION_RESPONSE message to BSS to trigger the position
response process. The TOM message is contained in LLC PDU,

Confidential and Proprietary Information of ZTE CORPORATION 29


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

and the LLC PDU contains the RRLP message of a MS. This
position response process is valid only when positioning a MS.
This counter counts the number of BSS's receiving the
POSITION_RESPONSE message.
Usage The counter is used to find out the frequency of SGSN's
requesting to implement positioning command to BSS.
Measurement When BSS receives the POSITION_RESPONSE message, the
Point counter increments. The measurement point is A2, as shown in
Figure 33.
Unit Times

C901310025
Definition Number of status messages sent
Description When NSE receives downlink BSSGP PDU, if there is any
abnormality, NSE will send the STATUS message to the opposite
end entity. The STATUS message sent indicates causes of the
abnormality: BVCI unknown, cell traffic congestion, Protocol
error, Processor overload, Semantically incorrect PDU, Invalid
mandatory information, Missing mandatory IE, or Missing
conditional IE. This counter counts the number of abnormality
that occurs.
Usage The counter is used to find out abnormality occurring when NSE
receives downlink BSSGP PDU.
Measurement When NSE at BSC sends message of which the type is STATUS
Point to opposite end entity, the counter increments. The
measurement point is A1, as shown in Figure 34.

FIGURE 34 – ST ATUS PROCESS

Unit Times

C901310026
Definition Number of status messages received
Description If the BSSGP PDU sent by NSE to SGSN is abnormal, NSE will
receive the STATUS message returned from the opposite end.
The STATUS message returned indicates causes of the
abnormality: BVCI unknown, cell traffic congestion, Protocol

30 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - NSE Statistic Measurement

error, Processor overload, Semantically incorrect PDU, Invalid


mandatory information, Missing mandatory IE, or Missing
conditional IE. This counter counts teh number of STATUS
messages returned from SGSN.
Usage The counter is used to find out abnormality occurring when
SGSN receives downlink BSSGP PDU.
Measurement When NSE receives the STATUS message, the counter
Point increments. The measurement point is A2, as shown in Figure 34.
Unit Times

C901310027
Definition Number of status messages sent with BVCI Unknown
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating "BVCI
unknown".
Usage The counter is used to find out the frequency of abnormality due
to "BVCI unknown" occurring when NSE receives downlink
BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to "BVCI
unknown", the counter increments.
Unit Times

C901310028
Definition Number of status messages sent with cell service congestion
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating "cell
traffic congestion".
Usage The counter is used to find out the frequency of abnormality due
to "cell traffic congestion" occurring when NSE receives downlink
BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to "cell
traffic congestion", the counter increments.
Unit Times

C901310029
Definition Number of status messages sent with protocol error
Description

Confidential and Proprietary Information of ZTE CORPORATION 31


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This counter counts the number of NSE's sending STATUS


message to opposite end entity, the message indicating
"Protocol error".
Usage The counter is used to find out the frequency of abnormality due
to "Protocol error" occurring when NSE receives downlink BSSGP
PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Protocol error", the counter increments.
Unit Times

C901310030
Definition Number of status messages sent with processor overload
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating
"Processor overload".
Usage The counter is used to find out the frequency of abnormality due
to "Processor overload" occurring when NSE receives downlink
BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Processor overload", the counter increments.
Unit Times

C901310031
Definition Number of status messages sent with semantically incorrect PDU
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating
"Semantically incorrect PDU".
Usage The counter is used to find out the frequency of abnormality due
to "Semantically incorrect PDU" occurring when NSE receives
downlink BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Semantically incorrect PDU", the counter increments.
Unit Times

C901310032
Definition

32 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - NSE Statistic Measurement

Number of status messages sent with invalid mandatory


information element
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating "Invalid
mandatory information".
Usage The counter is used to find out the frequency of abnormality due
to "Invalid mandatory information" occurring when NSE receives
downlink BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Invalid mandatory information", the counter increments.
Unit Times

C901310033
Definition Number of status messages sent with missing mandatory IE
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating "Missing
mandatory IE".
Usage The counter is used to find out the frequency of abnormality due
to "Missing mandatory IE" occurring when NSE receives
downlink BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Missing mandatory IE", the counter increments.
Unit Times

C901310034
Definition Number of status messages sent with missing conditional IE
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating "Missing
conditional IE".
Usage The counter is used to find out the frequency of abnormality due
to "Missing conditional IE" occurring when NSE receives
downlink BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Missing conditional IE", the counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 33


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901310035
Definition Number of status messages sent with unexpected conditional IE
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating
"Unexpected conditional IE".
Usage The counter is used to find out the frequency of abnormality due
to "Unexpected conditional IE" occurring when NSE receives
downlink BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Unexpected conditional IE", the counter increments.
Unit Times

C901310036
Definition Number of status messages sent with conditional IE error
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating
"Conditional IE error".
Usage The counter is used to find out the frequency of abnormality due
to "Conditional IE error" occurring when NSE receives downlink
BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Conditional IE error", the counter increments.
Unit Times

C901310037
Definition Number of status messages sent with protocol status
incompatible error
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating "PDU
not compatible with the protocol state".
Usage The counter is used to find out the frequency of abnormality due
to "PDU not compatible with the protocol state" occurring when
NSE receives downlink BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to "PDU
not compatible with the protocol state", the counter increments.
Unit Times

34 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - NSE Statistic Measurement

C901310038
Definition Number of status messages received with BVCI unknown
Description This counter counts the number of received STATUS messages
which indicate "BVCI unknown".
Usage The counter is used to find out the frequency of abnormality due
to "BVCI unknown" occurring when SGSN receives downlink
BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "BVCI
Point unknown", the counter increments.
Unit Times

C901310039
Definition Number of status messages received with cell service congestion
Description This counter counts the number of PCU's receiving STATUS
message from SGSN, the message indicating "cell traffic
congestion".
Usage The counter is used to find out the frequency of abnormality due
to "cell traffic congestion" occurring when SGSN receives
downlink BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "cell traffic
Point congestion", the counter increments.
Unit Times

C901310040
Definition Number of status messages received with protocol error
Description This counter counts the number of received STATUS messages
which indicate "Protocol error".
Usage The counter is used to find out the frequency of abnormality due
to "Protocol error" occurring when SGSN receives downlink
BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "Protocol
Point error", the counter increments.
Unit Times

C901310041
Definition Number of status messages received with processor overload

Confidential and Proprietary Information of ZTE CORPORATION 35


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Description This counter counts the number of PCU's receiving STATUS


message from SGSN, the message indicating "Processor
overload".
Usage The counter is used to find out the frequency of abnormality due
to "Processor overload" occurring when SGSN receives downlink
BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "Processor
Point overload", the counter increments.
Unit Times

C901310042
Definition Number of status messages received with BVC blocking
Description This counter counts the number of PCU's receiving STATUS
message from SGSN, the message indicating "BVCI-blocked".
Usage The counter is used to find out the frequency of abnormality due
to "BVCI-blocked" occurring when SGSN receives downlink
BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "BVCI-
Point blocked", the counter increments.
Unit Times

C901310043
Definition Number of status messages received with semantically incorrect
PDU
Description This counter counts the number of received STATUS messages
which indicate "Semantically incorrect PDU".
Usage The counter is used to find out the frequency of abnormality due
to "Semantically incorrect PDU" occurring when SGSN receives
downlink BSSGP PDU.
Measurement When PCU receives STATUS message which indicates
Point "Semantically incorrect PDU", the counter increments.
Unit Times

C901310044
Definition Number of status messages received with invalid mandatory IE
Description This counter counts the number of received STATUS messages
which indicate "Invalid mandatory information".
Usage

36 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - NSE Statistic Measurement

The counter is used to find out the frequency of abnormality due


to "Invalid mandatory information" occurring when SGSN
receives downlink BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "Invalid
Point mandatory information", the counter increments.
Unit Times

C901310045
Definition Number of status messages received with missing mandatory IE
Description This counter counts the number of received STATUS messages
which indicate "Missing mandatory IE".
Usage The counter is used to find out the frequency of abnormality due
to "Missing mandatory IE" occurring when SGSN receives
downlink BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "Missing
Point mandatory IE", the counter increments.
Unit Times

C901310046
Definition Number of status messages received with missing conditional IE
Description This counter counts the number of received STATUS messages
which indicate "Missing conditional IE".
Usage The counter is used to find out the frequency of abnormality due
to "Missing conditional IE" occurring when SGSN receives
downlink BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "Missing
Point conditional IE", the counter increments.
Unit Times

C901310047
Definition Number of status messages received with unexpected
conditional IE
Description This counter counts the number of received STATUS messages
which indicate "Unexpected conditional IE".
Usage The counter is used to find out the frequency of abnormality due
to "Unexpected conditional IE" occurring when SGSN receives
downlink BSSGP PDU.

Confidential and Proprietary Information of ZTE CORPORATION 37


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Measurement When PCU receives STATUS message which indicates


Point "Unexpected conditional IE", the counter increments.
Unit Times

C901310048
Definition Number of status messages received with conditional IE error
Description This counter counts the number of received STATUS messages
which indicate "Conditional IE error".
Usage The counter is used to find out the frequency of abnormality due
to "Conditional IE error" occurring when SGSN receives downlink
BSSGP PDU.
Measurement When PCU receives STATUS message which indicates
Point "Conditional IE error", the counter increments.
Unit Times

C901310049
Definition Number of status messages received with protocol status
incompatible error
Description This counter counts the number of received STATUS messages
which indicate "PDU not compatible with the protocol state".
Usage The counter is used to find out the frequency of abnormality due
to "PDU not compatible with the protocol state" occurring when
SGSN receives downlink BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "PDU not
Point compatible with the protocol state", the counter increments.
Unit Times

C901310050
Definition Number of status messages received with SGSN congestion
Description This counter counts the number of PCU's receiving STATUS
message from SGSN, the message indicating "SGSN congestion".
Usage The counter is used to find out the frequency of abnormality due
to "SGSN congestion" occurring when SGSN receives downlink
BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "SGSN
Point congestion", the counter increments.
Unit Times

38 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3

BTS TRX Measurement

The BTS TRX measurement performs statistics for transceiving


power, power change, and signal quality for each TRX. This
chapter introduces the meaning and measurement point of BTS
TRX measurement counters.

Overview
According to the receiving level and receiving quality in MS
measurement report and the receiving level and receiving
quality in BTS measurement, BTS decides whether to perform
power control for MS or BTS. BTS also performs statistics
according to different reasons for power control.
There are two ways for power control: common control and
rapid control. The power control amplitude in rapid control is
larger than that in common control. Besides, BTS periodically
samples the power of MS and BTS to get the average power.
After the power control measurement task is customized, BTS
periodically reports the power control statistic result to BSC
through the PC TEST RPT message. The power control
measurement result can be used to analyze coverage quality
and power control effect and frequency.
The power control measurement mechanism is shown in Figure
35. The measurement point for MS power control is A1, which is
after BTS sending the power control message to MS. The
measurement point for BTS power control is A2, which is after
BTS sending the power control message to itself. The
measurement point for periodical power sampling is A3. BSC
collects the power control measurement counter information
after it receives the PC TEST RPT message, which is at B1 as
shown in Figure 35.

Confidential and Proprietary Information of ZTE CORPORATION 39


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

FIGURE 35 – POWER CONTROL MEASUREMENT

MS BTS:TRX BSC

MS power
对MS功控
control
A1
TRX power
对TRX功控
control

A2
Periodically scanning MS
power and BTS power

A3
PC TEST RPT

Statistic unit in this measurement is TRX.

BTS TRX Measurement Counter


Index
Table 7 lists counters related to BTS TRX measurement

TABLE 7 – BTS TRX MEASUREMENT COUNTERS

Counter ID What It Counts


Number of normal increases of MS power due
C901320001
to UL signal level
Number of rapid increase in MS power due to
C901320002
UL signal level
Number of normal decrease of MS power due
C901320003
to UL signal level
Number of rapid decrease in MS power due to
C901320004
UL signal level
Number of normal increases of BS power due
C901320005
to DL signal level
Number of rapid increase in BTS power due to
C901320006
DL signal level
Number of normal decrease of BS power due
C901320007
to DL signal level
Number of rapid decrease in power BTS due to
C901320008
DL signal level
Number of normal increases of MS power due
C901320009
to UL signal quality

40 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - BTS TRX Measurement

Counter ID What It Counts


Number of rapid increase in MS power due to
C901320010
UL signal quality
Number of normal decrease of MS power due
C901320011
to UL signal quality
Number of rapid decrease in MS power due to
C901320012
UL signal quality
Number of normal increases of BS power due
C901320013
to DL signal quality
Number of rapid increase in BTS power due to
C901320014
DL signal quality
Number of normal decrease of BS power due
C901320015
to DL signal quality
Number of rapid decrease in BTS power due to
C901320016
DL signal quality
Total value of each result of regular scanning
C901320017
of MS utilization power
Number of regular scanning and sampling of
C901320018
MS utilization power
Total value of each result of regular scanning
C901320019
of BS utilization power
Number of regular scanning and sampling of
C901320020
BS utilization power
C901320021 Total value of power scans of DL signal level
C901320022 Number of power scans of DL signal level
C901320023 Total value of power scans of UL signal level
C901320024 Number of power scans of UL signal level
C901320025 Total value of power scans of DL signal quality
C901320026 Number of power scans of DL signal quality
C901320027 Total value of power scans of UL signal quality
C901320028 Number of power scans of UL signal quality
Maximum value of UL signal level in regular
C901320029
scan
Minimum value of UL signal level in regular
C901320030
scan
Maximum value obtained in regular scan of DL
C901320031
signal level
Minimum value obtained in regular scan of DL
C901320032
signal level
Sum of Periodic BS Power (TCH/F) Search
C901320033
Result
C901320034 Periodic BS Power (TCH/F) Search Times
Sum of Periodic BS Power (TCH/H) Search
C901320035
Result

Confidential and Proprietary Information of ZTE CORPORATION 41


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Counter ID What It Counts


C901320036 Number of Periodic BS Power (TCH/H) Search
Sum of Periodic BS Power (SDCCH) Search
C901320037
Result
C901320038 Number of Periodic BS Power (SDCCH) Search
Sum of Periodic DL Signal Level (TCH/F)
C901320039
Search Result
Number of Periodic DL Signal Level (TCH/F)
C901320040
Search
Sum of Periodic DL Signal Level (TCH/H)
C901320041
Search Result
Number of Periodic DL Signal Level (TCH/H)
C901320042
Search
Sum of Periodic DL Signal Level (SDCCH)
C901320043
Search Result
Number of Periodic DL Signal Level (SDCCH)
C901320044
Search

C901320001
Definition Number of normal increases of MS power due to UL signal level
Description In common power control, after BTS measures the uplink level
and quality of MS, it compares the MS's uplink level with the
configured uplink receiving level threshold according to the
power control algorithm and makes decision. If BTS decides to
increase MS's transmission power, it sends the message of
increasing transmission power to MS, and the counter
increments.
Measurement The counter counts when BTS sends the message of increasing
Point transmission power to MS. The measurement point is A1, as
shown in Figure 35.
Unit Times

C901320002
Definition Number of rapid increase in MS power due to UL signal level
Description In rapid power control, after BTS measures the uplink level and
quality of MS, it compares the MS's uplink level with the
configured uplink receiving level threshold according to the
power control algorithm and makes decision. If BTS decides to
increase MS's transmission power, it sends the message of
increasing transmission power to MS, and the counter
increments.

42 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - BTS TRX Measurement

Measurement The counter counts when BTS sends the message of increasing
Point transmission power to MS. The measurement point is A1, as
shown in Figure 35.
Unit Times

C901320003
Definition Number of normal decrease of MS power due to UL signal level
Description In common power control, after BTS measures the uplink level
and quality of MS, it compares the MS's uplink level with the
configured uplink receiving level threshold according to the
power control algorithm and makes decision. If BTS decides to
decrease MS's transmission power, it sends the message of
decreasing transmission power to MS, and the counter
increments.
Measurement The counter counts when BTS sends the message of decreasing
Point transmission power to MS. The measurement point is A1, as
shown in Figure 35.
Unit Times

C901320004
Definition Number of rapid decrease in MS power due to UL signal level
Description In rapid power control, after BTS measures the uplink level and
quality of MS, it compares the MS's uplink level with the
configured uplink receiving level threshold according to the
power control algorithm and makes decision. If BTS decides to
decrease MS's transmission power, it sends the message of
decreasing transmission power to MS, and the counter
increments.
Measurement The counter counts when BTS sends the message of decreasing
Point transmission power to MS. The measurement point is A1, as
shown in Figure 35.
Unit Times

C901320005
Definition Number of normal increases of BS power due to DL signal level
Description In common power control, after BTS receives the MS
measurement report, it compares the MS's downlink receiving
level with the configured downlink receiving level threshold
according to the power control algorithm and makes decision. If
BTS decides to increase BTS's transmission power, it sends the

Confidential and Proprietary Information of ZTE CORPORATION 43


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

message of increasing transmission power to BTS, and the


counter increments.
Measurement The counter counts when BTS sends the message of increasing
Point transmission power to itself. The measurement point is A2, as
shown in Figure 35.
Unit Times

C901320006
Definition Number of rapid increase in BTS power due to DL signal level
Description In rapid power control, after BTS receives the MS measurement
report, it compares the MS's downlink receiving level and quality
with the configured downlink receiving level threshold and
downlink receiving quality threshold according to the power
control algorithm and makes decision. If BTS decides to increase
BTS's transmission power, it sends the message of increasing
transmission power to BTS, and the counter increments.
Measurement The counter counts when BTS sends the message of increasing
Point transmission power to itself. The measurement point is A2, as
shown in Figure 35.
Unit Times

C901320007
Definition Number of normal decrease of BS power due to DL signal level
Description In common power control, after BTS receives the MS
measurement report, it compares the MS's downlink receiving
level with the configured downlink receiving level threshold
according to the power control algorithm and makes decision. If
BTS decides to decrease BTS's transmission power, it sends the
message of decreasing transmission power to BTS, and the
counter increments.
Measurement The counter counts when BTS sends the message of decreasing
Point transmission power to itself. The measurement point is A2, as
shown in Figure 35.
Unit Times

C901320008
Definition Number of rapid decrease in power BTS due to DL signal level
Description In rapid power control, after BTS receives the MS measurement
report, it compares the MS's downlink receiving level with the
configured downlink receiving level threshold according to the

44 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - BTS TRX Measurement

power control algorithm and makes decision. If BTS decides to


decrease BTS's transmission power, it sends the message of
decreasing transmission power to BTS, and the counter
increments.
Measurement The counter counts when BTS sends the message of decreasing
Point transmission power to itself. The measurement point is A2, as
shown in Figure 35.
Unit Times

C901320009
Definition Number of normal increases of MS power due to UL signal
quality
Description In common power control, after BTS measures the uplink level
and quality of MS, it compares the MS's uplink quality with the
configured uplink receiving quality threshold according to the
power control algorithm and makes decision. If BTS decides to
increase MS's transmission power, it sends the message of
increasing transmission power to MS, and the counter
increments.
Measurement The counter counts when BTS sends the message of increasing
Point transmission power to MS. The measurement point is A1, as
shown in Figure 35.
Unit Times

C901320010
Definition Number of rapid increase in MS power due to UL signal quality
Description In rapid power control, after BTS measures the uplink level and
quality of MS, it compares the MS's uplink quality with the
configured uplink receiving quality threshold according to the
power control algorithm and makes decision. If BTS decides to
increase MS's transmission power, it sends the message of
increasing transmission power to MS, and the counter
increments.
Measurement The counter counts when BTS sends the message of increasing
Point transmission power to MS. The measurement point is A1, as
shown in Figure 35.
Unit Times

C901320011
Definition Number of normal decrease of MS power due to UL signal quality

Confidential and Proprietary Information of ZTE CORPORATION 45


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Description In common power control, after BTS measures the uplink level
and quality of MS, it compares the MS's uplink quality with the
configured uplink receiving quality threshold according to the
power control algorithm and makes decision. If BTS decides to
decrease MS's transmission power, it sends the message of
decreasing transmission power to MS, and the counter
increments.
Measurement The counter counts when BTS sends the message of decreasing
Point transmission power to MS. The measurement point is A1, as
shown in Figure 35.
Unit Times

C901320012
Definition Number of rapid decrease in MS power due to UL signal quality
Description In rapid power control, after BTS measures the uplink level and
quality of MS, it compares the MS's uplink quality with the
configured uplink receiving quality threshold according to the
power control algorithm and makes decision. If BTS decides to
decrease MS's transmission power, it sends the message of
decreasing transmission power to MS, and the counter
increments.
Measurement The counter counts when BTS sends the message of decreasing
Point transmission power to MS. The measurement point is A1, as
shown in Figure 35.
Unit Times

C901320013
Definition Number of normal increases of BS power due to DL signal
quality
Description In common power control, after BTS receives the MS
measurement report, it compares the MS's downlink receiving
quality with the configured downlink receiving quality threshold
according to the power control algorithm and makes decision. If
BTS decides to increase BTS's transmission power, it sends the
message of increasing transmission power to BTS, and the
counter increments.
Measurement The counter counts when BTS sends the message of increasing
Point transmission power to itself. The measurement point is A2, as
shown in Figure 35.
Unit Times

46 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - BTS TRX Measurement

C901320014
Definition Number of rapid increase in BTS power due to DL signal quality
Description In rapid power control, after BTS receives the MS measurement
report, it compares the MS's downlink receiving quality with the
configured downlink receiving quality threshold according to the
power control algorithm and makes decision. If BTS decides to
increase BTS's transmission power, it sends the message of
increasing transmission power to BTS, and the counter
increments.
Measurement The counter counts when BTS sends the message of increasing
Point transmission power to itself. The measurement point is A2, as
shown in Figure 35.
Unit Times

C901320015
Definition Number of normal decrease of BS power due to DL signal quality
Description In common power control, after BTS receives the MS
measurement report, it compares the MS's downlink receiving
quality with the configured downlink receiving quality threshold
according to the power control algorithm and makes decision. If
BTS decides to decrease BTS's transmission power, it sends the
message of decreasing transmission power to BTS, and the
counter increments.
Measurement The counter counts when BTS sends the message of decreasing
Point transmission power to itself. The measurement point is A2, as
shown in Figure 35.
Unit Times

C901320016
Definition Number of rapid decrease in BTS power due to DL signal quality
Description In rapid power control, after BTS receives the MS measurement
report, it compares the MS's downlink receiving quality with the
configured downlink receiving quality threshold according to the
power control algorithm and makes decision. If BTS decides to
decrease BTS's transmission power, it sends the message of
decreasing transmission power to BTS, and the counter
increments.
Measurement The counter counts when BTS sends the message of decreasing
Point transmission power to itself. The measurement point is A2, as
shown in Figure 35.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 47


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901320017
Definition Total value of each result of regular scanning of MS utilization
power
Description To get the average MS utilization power on TRX, BTS periodically
scans the MS utilization power on channels of TRX and
accumulates the value. During the period of reporting
measurement result to BSC, BTS may perform multiple
periodical scannings. This counter accumulates the MS utilization
power value of each scanning.
Measurement The counter accumulates when BTS performs periodical scanning.
Point The measurement point is A3, as shown in Figure 35.
Unit Grade

C901320018
Definition Number of regular scanning and sampling of MS utilization
power
Description To get the average MS utilization power on TRX, BTS periodically
scans the MS utilization power on channels of TRX and
accumulates the value. Each time a MS utilization power value is
accumulated, the counter increments. During the period of
reporting measurement result to BSC, BTS may perform multiple
periodical scannings. This counter accumulates the number of
periodical scannings.
Measurement The counter counts when BTS performs periodical scanning. The
Point measurement point is A3, as shown in Figure 35.
Unit Times

C901320019
Definition Total value of each result of regular scanning of BS utilization
power
Description To get the average utilization power on TRX, BTS periodically
scans the utilization power on channels of TRX and accumulates
the value. During the period of reporting measurement result to
BSC, BTS may perform multiple periodical scannings. This
counter accumulates the BTS utilization power value of each
scanning.
Measurement The counter accumulates when BTS performs periodical scanning.
Point The measurement point is A3, as shown in Figure 35.
Unit Grade

48 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - BTS TRX Measurement

C901320020
Definition Number of regular scanning and sampling of BS utilization power
Description To get the average utilization power on TRX, BTS periodically
scans the utilization power on channels of TRX and accumulates
the value. Each time a channel utilization power value is
accumulated, the counter increments. During the period of
reporting measurement result to BSC, BTS may perform multiple
periodical scannings. This counter accumulates the number of
periodical scannings.
Measurement The counter counts when BTS performs periodical scanning. The
Point measurement point is A3, as shown in Figure 35.
Unit Times

C901320021
Definition Total value of power scans of DL signal level
Description To get the average downlink signal level received by MS on TRX,
BTS periodically scans the downlink signal level reported by MS
on channels of TRX and accmulates. During the period of
reporting measurement result to BSC, BTS may perform multiple
periodical scannings. This counter accumulates the MS downlink
signal level value of each scanning.
Measurement The counter counts when BTS performs periodical scanning. The
Point measurement point is A3, as shown in Figure 35.
Unit Grade

C901320022
Definition Number of power scans of DL signal level
Description To get the average downlink signal level received by MS on TRX,
BTS periodically scans the downlink signal level reported by MS
on channels of TRX and accmulates. Each time a measured
downlink signal level is accumulated, the counter increments.
During the period of reporting measurement result to BSC, BTS
may perform multiple periodical scannings. This counter
accumulates the number of periodical scannings.
Measurement The counter counts when BTS performs periodical scanning. The
Point measurement point is A3, as shown in Figure 35.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 49


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901320023
Definition Total value of power scans of UL signal level
Description To get the average uplink signal level received by TRX, BTS
periodically scans the uplink signal level on channels of TRX and
accmulates. During the period of reporting measurement result
to BSC, BTS may perform multiple periodical scannings. This
counter accumulates the uplink signal level value of each
scanning.
Measurement The counter counts when BTS performs periodical scanning. The
Point measurement point is A3, as shown in Figure 35.
Unit Grade

C901320024
Definition Number of power scans of UL signal level
Description To get the average uplink signal level received by TRX, BTS
periodically scans the uplink signal level on channels of TRX and
accmulates. Each time a uplink signal level is accumulated, the
counter increments. During the period of reporting measurement
result to BSC, BTS may perform multiple periodical scannings.
This counter accumulates the number of periodical scannings.
Measurement The counter counts when BTS performs periodical scanning. The
Point measurement point is A3, as shown in Figure 35.
Unit Times

C901320025
Definition Total value of power scans of DL signal quality
Description To get the average downlink signal quality received by MS on
TRX, BTS periodically scans the downlink signal quality reported
by MS on channels of TRX and accmulates. During the period of
reporting measurement result to BSC, BTS may perform multiple
periodical scannings. This counter accumulates the MS downlink
signal quality value of each scanning.
Measurement The counter counts when BTS performs periodical scanning. The
Point measurement point is A3, as shown in Figure 35.
Unit Grade

C901320026
Definition Number of power scans of DL signal quality

50 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - BTS TRX Measurement

Description To get the average downlink signal quality received by MS on


TRX, BTS periodically scans the downlink signal quality reported
by MS on channels of TRX and accmulates. Each time a
measured downlink signal quality is accumulated, the counter
increments. During the period of reporting measurement result
to BSC, BTS may perform multiple periodical scannings. This
counter accumulates the number of periodical scannings.
Measurement The counter counts when BTS performs periodical scanning. The
Point measurement point is A3, as shown in Figure 35.
Unit Times

C901320027
Definition Total value of power scans of UL signal quality
Description To get the average uplink signal quality received by TRX, BTS
periodically scans the uplink signal quality on channels of TRX
and accmulates. During the period of reporting measurement
result to BSC, BTS may perform multiple periodical scannings.
This counter accumulates the uplink signal quality value of each
scanning.
Measurement The counter counts when BTS performs periodical scanning. The
Point measurement point is A3, as shown in Figure 35.
Unit Grade

C901320028
Definition Number of power scans of UL signal quality
Description To get the average uplink signal quality received by TRX, BTS
periodically scans the uplink signal quality on channels of TRX
and accmulates. Each time a uplink signal quality is accumulated,
the counter increments. During the period of reporting
measurement result to BSC, BTS may perform multiple
periodical scannings. This counter accumulates the number of
periodical scannings.
Measurement The counter counts when BTS performs periodical scanning. The
Point measurement point is A3, as shown in Figure 35.
Unit Times

C901320029
Definition Maximum value of UL signal level in regular scan
Description

Confidential and Proprietary Information of ZTE CORPORATION 51


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

When BSC collects information of power control measurement


counters, this counter records the maximum uplink signal level
value.
Measurement The counter counts when BSC receives the reported power
Point control measurement message PC TEST RPT. The measurement
point is B1, as shown in Figure 35.
Unit Grade

C901320030
Definition Minimum value of UL signal level in regular scan
Description When BSC collects information of power control measurement
counters, this counter records the minimum uplink signal level
value.
Measurement The counter counts when BSC receives the reported power
Point control measurement message PC TEST RPT. The measurement
point is B1, as shown in Figure 35.
Unit Grade

C901320031
Definition Maximum value obtained in regular scan of DL signal level
Description When BSC collects information of power control measurement
counters, this counter records the maximum downlink signal
level value.
Measurement The counter counts when BSC receives the reported power
Point control measurement message PC TEST RPT. The measurement
point is B1, as shown in Figure 35.
Unit Grade

C901320032
Definition Minimum value obtained in regular scan of DL signal level
Description When BSC collects information of power control measurement
counters, this counter records the minimum downlink signal
level value.
Measurement The counter counts when BSC receives the reported power
Point control measurement message PC TEST RPT. The measurement
point is B1, as shown in Figure 35.
Unit Grade

52 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - BTS TRX Measurement

C901320033
Definition Sum of Periodic BS Power (TCH/F) Search Result
Description This counter records the total value of BS power (TCH/F) of
periodical scannings.
Measurement When the power control message is received and if the channel
Point is TCH/F, then obtain the BS power in the message and
accumulate.
Unit Grade

C901320034
Definition Periodic BS Power (TCH/F) Search Times
Description This counter counts the number of periodical scanning of BS
power (TCH/F).
Measurement When the power control message is received, if the channel is
Point TCH/F and the message contains BS power information, then the
counter increments.
Unit Times

C901320035
Definition Sum of Periodic BS Power (TCH/H) Search Result
Description This counter records the total value of BS power (TCH/H) of
periodical scannings.
Measurement When the power control message is received and if the channel
Point is TCH/H, then obtain the BS power in the message and
accumulate.
Unit Grade

C901320036
Definition Number of Periodic BS Power (TCH/H) Search
Description This counter counts the number of periodical scanning of BS
power (TCH/H).
Measurement When the power control message is received, if the channel is
Point TCH/H and the message contains BS power information, then
the counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 53


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901320037
Definition Sum of Periodic BS Power (SDCCH) Search Result
Description This counter records the total value of BS power (SDCCH) of
periodical scannings.
Measurement When the power control message is received and if the channel
Point is SDCCH, then obtain the BS power in the message and
accumulate.
Unit Grade

C901320038
Definition Number of Periodic BS Power (SDCCH) Search
Description This counter counts the number of periodical scanning of BS
power (SDCCH).
Measurement When the power control message is received, if the channel is
Point SDCCH and the message contains BS power information, then
the counter increments.
Unit Times

C901320039
Definition Sum of Periodic DL Signal Level (TCH/F) Search Result
Description This counter records the total value of downlink signal level
(TCH/F) of periodical scannings.
Measurement When the power control message is received and if the channel
Point is TCH/F, then obtain the downlink signal level in the message
and accumulate.
Unit Grade

C901320040
Definition Number of Periodic DL Signal Level (TCH/F) Search
Description This counter counts the number of periodical scanning of
downlink signal level (TCH/F).
Measurement When the power control message is received, if the channel is
Point TCH/F and the message contains downlink signal level
information, then the counter increments.
Unit Times

54 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - BTS TRX Measurement

C901320041
Definition Sum of Periodic DL Signal Level (TCH/H) Search Result
Description This counter records the total value of downlink signal level
(TCH/H) of periodical scannings.
Measurement When the power control message is received and if the channel
Point is TCH/H, then obtain the downlink signal level in the message
and accumulate.
Unit Grade

C901320042
Definition Number of Periodic DL Signal Level (TCH/H) Search
Description This counter counts the number of periodical scanning of
downlink signal level (TCH/H).
Measurement When the power control message is received, if the channel is
Point TCH/H and the message contains downlink signal level
information, then the counter increments.
Unit Times

C901320043
Definition Sum of Periodic DL Signal Level (SDCCH) Search Result
Description This counter records the total value of downlink signal level
(SDCCH) of periodical scannings.
Measurement When the power control message is received and if the channel
Point is SDCCH, then obtain the downlink signal level in the message
and accumulate.
Unit Grade

C901320044
Definition Number of Periodic DL Signal Level (SDCCH) Search
Description This counter counts the number of periodical scanning of
downlink signal level (SDCCH).
Measurement When the power control message is received, if the channel is
Point SDCCH and the message contains downlink signal level
information, then the counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 55


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This page is intentionally blank.

56 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4

NSVC on IPGB HOST


Measurement

The NSVC statistic measurement on IPGB HOST takes NSVC as


the measurement entity. It performs statistics for data
transmission, signaling interaction, and link transceiving
abnormality for NSVC link. This chapter introduces the meaning,
usage, and measurement point of counters of NSVC statistic
measurement on IPGB HOST.

Overview
The NSVC statistic measurement on IPGB HOST is used to
measure signaling interaction and data transmission at NS layer
of Gb interface in GPRS service. It also performs statistics for
abnormalities in various flows.
Statistic unit in this measurement is NSVC.

NSVC on IPGB HOST Measurement


Counter Index
Table 8 lists counters related to NSVC on IPGB HOST
measurement.

TABLE 8 – COUNTERS OF NSVC MEASUREMENT ON IPGB HOST

Counter ID What It Counts


C901330001 Time of PVC unavailable
Number of abnormal cases in NS
C901330002
transmission due to network fault
Number of abnormal cases in NS
C901330003
transmission due to O&M interference

Confidential and Proprietary Information of ZTE CORPORATION 57


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Counter ID What It Counts


Number of abnormal cases in NS
C901330004
transmission due to equipment fault
Number of abnormal cases in NS
C901330005
transmission due to unknown NSVC
Number of abnormal cases in NS
C901330006
transmission due to protocol error
C901330007 Number of unsuccess test due to over max

C901330001
Definition Time of PVC unavailable
Description This counter counts the time during which NSVC can not be used
for data transmission.
Measurement The counter starts counting when NSVC link becomes abnormal
Point and stops counting when NSVC link becomes normal. The
duration between the two time points is the time during which
NSVC is unavailable.
Unit Second

C901330002
Definition Number of abnormal cases in NS transmission due to network
fault
Description This counter is not used for the time being.

C901330003
Definition Number of abnormal cases in NS transmission due to O&M
interference
Description This counter is not used for the time being.

C901330004
Definition Number of abnormal cases in NS transmission due to equipment
fault
Description This counter is not used for the time being.

58 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - NSVC on IPGB HOST Measurement

C901330005
Definition Number of abnormal cases in NS transmission due to unknown
NSVC
Description This counter counts the number of abnormal cases in NS sub
layer transmission due to unknown NSVC.
Measurement During the NS sub layer signaling interaction, the counter
Point accumulates the number of signaling transmitted by unknown
NSVC.
Unit Times

C901330006
Definition Number of abnormal cases in NS transmission due to protocol
error
Description This counter counts the number of abnormal cases in NS sub
layer transmission due to protocol error.
Measurement When the field in NS signaling is inconsistent with that defined in
Point protocol, the counter accumulates.
Unit Times

C901330007
Definition Number of unsuccess test due to over max
Description This counters counts the number of test failure due to the
maximum retransmission times being exceeded during the NS
sub layer test procedure.
Measurement When the number of NS sub layer's sending NS-ALIVE PDU
Point exceeds the maximum retransmission times NS-ALIVE-RETRIES
and there is no response, the counter increments. The
measurement point is A1, as shown in Figure 36.

Confidential and Proprietary Information of ZTE CORPORATION 59


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

FIGURE 36 – TEST PROCEDURE BEING ABNORMAL

BSC SGSN
NS-ALIVE

Tns-alive
NS-ALIVE
. NS-ALIVE-
. RETRIES

Tns-alive .
NS-ALIVE
A1

Unit Times

60 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5

GB Message on IPGB
HOST Measurement

The Gb interface message measurement on IPGB HOST takes


cell as the measurement entity. It performs measurement for
transceiving of PTP messages at BSSGP layer of Gb interface.
This chapter introduces the meaning, usage, and measurement
point of counters of Gb interface message measurement on IPGB
HOST.

Overview
The Gb interface message measurement on IPGB HOST
measures the number of transceiving various PTP messages at
BSSGP layer of Gb interface in GPRS service, such as RA-
CAPABILITY, RADIO-STATUS, and DOWNLOAD-BSS-PFC.
Statistic unit in this measurement is cell.

GB Message on IPGB HOST


Measurement Counter Index
Table 9 lists counters related to GB Message on IPGB HOST
Measurement.

TABLE 9 – COUNTERS OF GB INTERFACE MESSAGE MEASUREMENT ON IPGB


HOST

Counter ID What It Counts


C901340001 Number of RA-CAPABILITY message recevied
C901340002 Number of PTP packet paging received by BSC
C901340003 Number of PTP circuit paging received by BSC
C901340004 Number of RA-CAPABILITY-UPDATE message sent

Confidential and Proprietary Information of ZTE CORPORATION 61


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Counter ID What It Counts


Number of RA-CAPABILITY-UPDATE-ACK message
C901340005
received
Number of wireless status PDU messages sent by
C901340006
BSC
Number of wireless status messages sent by BSC
C901340007
due to losing wireless association with MS
Number of wireless status messages sent by BSC
C901340008
due to bad link quality
Number of wireless status messages sent by BSC
C901340009
due to cell reelection command
Number of FLOW-CONTROL-BVC messages sent by
C901340010
BSC
Number of FLOW-CONTROL-BVC-ACK messages
C901340011
received by BSC
Number of FLOW-CONTROL-MS messages sent by
C901340012
BSC
Number of FLOW-CONTROL-MS-ACK messages
C901340013
received by BSC
Number of FLOW-CONTROL-PFC messages sent by
C901340014
BSC
Number of FLOW-CONTROL-PFC-ACK messages
C901340015
received by BSC
C901340016 Number of status messages sent by BSC
C901340017 Number of status messages received by BSC
Number of status messages sent with BVCI
C901340018
Unknown
Number of status messages sent with cell service
C901340019
congestion
Number of status messages sent with protocol
C901340020
error
Number of status messages sent with Processor
C901340021
overload
Number of status messages received with BVCI
C901340022
Unknown
Number of status messages received with cell
C901340023
service congestion
Number of status messages received with protocol
C901340024
error
Number of status messages received with
C901340025
processor overload
Number of DOWNLOAD-BSS-PFC messages sent
C901340026
by BSC
Number of BVCCREATE-BSS-PFC messages
C901340027
received by BSC

62 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - GB Message on IPGB HOST Measurement

Counter ID What It Counts


Number of CREATE-BSS-PFC-ACK messages sent
C901340028
by BSC
Number of CREATE-BSS-PFC-NACK messages sent
C901340029
by BSC
Number of MODIFY-BSS-PFC messages sent by
C901340030
BSC
Number of MODIFY-BSS-PFC-ACK messages
C901340031
received by BSC
Number of DELETE-BSS-PFC messages received by
C901340032
BSC
Number of DELETE-BSS-PFC-ACK messages sent
C901340033
by BSC
Number of DELETE-BSS-PFC-REQ messages
C901340034
received by BSC

C901340001
Definition Number of RA-CAPABILITY message received
Description SGSN sends the RA-CAPABILITY message to BSC to indicate the
wireless capability of MS. This counter counts the number of
BSC's receiving this message.
Measurement When BSC receives a “RA-CAPABILITY” message, this counter
Point increments. The measurement point is A, as shown in Figure 37.

FIGURE 37 – MEASUREMENT POINT OF THE NUMBER OF RECEIVING RA-


C AP A B I L I T Y M E S S A G E

Unit Times

C901340002
Definition Number of PTP packet paging received by BSC
Description SGSN sends the PTP packet paging message to indicate BSC to
initiate PTP packet paging for MS. This counter counts the
number of BSC's receiving this message.
Measurement When BSC receives a “PAGING PS” message, this counter
Point increments. The measurement point is A, as shown in Figure 38.

Confidential and Proprietary Information of ZTE CORPORATION 63


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

FIGURE 38 – PTP P ACKET P AGING PROCESS

BSC SGSN

PAGING PS

Unit Times

C901340003
Definition Number of PTP circuit paging recevied by BSC
Description SGSN sends the PTP circuit paging message to indicate BSC to
initiate PTP circuit paging for MS. This counter counts the
number of BSC's receiving this message.
Measurement When BSC receives a “PAGING CS” message, this counter
Point increments. The measurement point is A, as shown in Figure 39.

FIGURE 39 – PTP CIRCUIT P AGING PROCESS

Unit Times

C901340004
Definition Number of RA-CAPABILITY-UPDATE message sent
Description BSC sends the RA-CAPABILITY-UPDATE message to SGSN to
request for the current wireless capability of MS. This counter
counts the number of BSC's sending this message.
Measurement When BSC sends a “RA-CAPABILITY-UPDATE” message to SGSN,
Point this counter increments. The measurement point is A1, as shown
in Figure 40.

FIGURE 40 – R A-C AP ABILITY-UPDATE PROCESS

64 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - GB Message on IPGB HOST Measurement

Unit Times

C901340005
Definition Number of RA-CAPABILITY-UPDATE-ACK message received
Description SGSN sends the RA-CAPABILITY-UPDATE-ACK message to BSC
to indicate the current wireless capability of MS. This counter
counts the number of BSC's receiving this message.
Measurement When BSC receives a “RA-CAPABILITY-UPDATE-ACK” message
Point from SGSN, this counter increments. The measurement point is
A2, as shown in Figure 40.
Unit Times

C901340006
Definition Number of wireless status PDU messages sent by BSC
Description BSC sends the wireless status PDU message to indicate SGSN
that abnormality occurs at radio interface. This counter counts
the number of BSC's sending this message.
Usage The radio interface status can be checked by counting this
message.
Measurement When BSC sends a “RADIO-STATUS” message to SGSN, this
Point counter increments. The measurement point is A, as shown in
Figure 41.

FIGURE 41 – R ADIO-ST AT US PROCESS

Unit Times

C901340007
Definition Number of wireless status messages sent by BSC due to losing
wireless association with MS
Description BSC sends the wireless status message to indicate SGSN that
abnormality occurs at radio interface. This counter counts the
number of BSC's sending this message due to “Losing wireless
association with MS”.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 65


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

The radio interface status can be checked by counting this


message.
Measurement When BSC sends a RADIO-STATUS message to SGSN due to
Point “Losing wireless association with MS”, this counter increments.
Unit Times

C901340008
Definition Number of wireless status messages sent by BSC due to bad link
quality
Description BSC sends the wireless status message to indicate SGSN that
abnormality occurs at radio interface. This counter counts the
number of BSC's sending this message due to “bad link quality”.
Usage The radio interface status can be checked by counting this
message.
Measurement When BSC sends a RADIO-STATUS message to SGSN due to
Point “bad link quality”, this counter increments.
Unit Times

C901340009
Definition Number of wireless status messages sent by BSC due to cell
reelection command
Description BSC sends the wireless status message to indicate SGSN that
abnormality occurs at radio interface. This counter counts the
number of BSC's sending this message due to “cell reselection
command”.
Usage The radio interface status can be checked by counting this
message.
Measurement When BSC sends a RADIO-STATUS message to SGSN due to
Point “cell reselection command”, this counter increments.
Unit Times

C901340010
Definition Number of FLOW-CONTROL-BVC messages sent by BSC
Description BSC sends the FLOW-CONTROL-BVC message to notify SGSN of
the current BVC flow control policy. This counter counts the
number of BSC's sending this message.
Measurement When BSC sends a “FLOW-CONTROL-BVC” message, this
Point counter increments. The measuremnt point is A1, as shown in
Figure 42.

66 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - GB Message on IPGB HOST Measurement

FIGURE 42 – FLOW-CONTROL-BVC PROCESS

Unit Times

C901340011
Definition Number of FLOW-CONTROL-BVC-ACK messages received by BSC
Description SGSN sends the FLOW-CONTROL-BVC-ACK message to notify
BSC that the current BVC flow control policy is accepted. This
counter counts the number of BSC's receiving this message.
Measurement When BSC receives a “FLOW-CONTROL-BVC-ACK” message, this
Point counter increments. The measurement point is A2, as shown in
Figure 42.
Unit Times

C901340012
Definition Number of FLOW-CONTROL-MS messages sent by BSC
Description BSC sends the FLOW-CONTROL-MS message to notify SGSN of
the current MS flow control policy. This counter counts the
number of BSC's sending this message.
Measurement When BSC sends the “FLOW-CONTROL-MS” message, this
Point counter increments. The measurement point is A1, as shown in
Figure 43.

FIGURE 43 – FLOW-CONTROL-MS PROCESS

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 67


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901340013
Definition Number of FLOW-CONTROL-MS-ACK messages received by BSC
Description SGSN sends the FLOW-CONTROL-MS-ACK message to notify
BSC that the current MS flow control policy is accepted. This
counter counts the number of BSC's receiving this message.
Measurement When BSC receives a “FLOW-CONTROL-MS-ACK” message, this
Point counter increments. The measurement point is A2, as shown in
Figure 43.
Unit Times

C901340014
Definition Number of FLOW-CONTROL-PFC messages sent by BSC
Description BSC sends the FLOW-CONTROL-PFC message to notify SGSN of
the flow control policy for one or multiple PFCs of designated MS.
This counter counts the number of BSC's sending this message.
Measurement When BSC sends the “FLOW-CONTROL-PFC” message, this
Point counter increments. The measurement point is A1, as shown in
Figure 44.

FIGURE 44 – FLOW-CONTROL-PFC PROCESS

Unit Times

C901340015
Definition Number of FLOW-CONTROL-PFC-ACK messages received by BSC
Description SGSN sends the FLOW-CONTROL-PFC-ACK message to notify
BSC that the PFC flow control policy for designated MS is
accepted. This counter counts the number of BSC's receiving this
message.
Measurement When BSC receives a “FLOW-CONTROL-PFC-ACK” message, this
Point counter increments. The measurement point is A2, as shown in
Figure 44.
Unit Times

68 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - GB Message on IPGB HOST Measurement

C901340016
Definition Number of status messages sent by BSC
Description BSC sends the status message to SGSN to indicate that
abnormality occurs. This counter counts the number of BSC's
sending this message.
Measurement When BSC sends the “STATUS” message, this counter
Point increments. The measurement point is A1, as shown in Figure 45.

FIGURE 45 – ST ATUS PROCESS

Unit Times

C901340017
Definition Number of status messages received by BSC
Description SGSN sends the status message to BSC to indicate that
abnormality occurs. This counter counts the number of BSC's
receiving this message.
Measurement When BSC receives the “STATUS” message, this counter
Point increments. The measurement point is A2, as shown in Figure 45.
Unit Times

C901340018
Definition Number of status messages sent with BVCI Unknown
Description BSC sends the status message to SGSN to indicate that
abnormality occurs. This counter counts the number of BSC's
sending this message due to “BVCI Unknown”.
Measurement When BSC sends a "STATUS" message due to “BVCI Unknown”,
Point this counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 69


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901340019
Definition Number of status messages sent with cell service congestion
Description BSC sends the status message to SGSN to indicate that
abnormality occurs. This counter counts the number of BSC's
sending this message due to “cell service congestion”.
Measurement When BSC sends a "STATUS" message due to “cell service
Point congestion”, this counter increments.
Unit Times

C901340020
Definition Number of status messages sent with protocol error
Description BSC sends the status message to SGSN to indicate that
abnormality occurs. This counter counts the number of BSC's
sending this message due to “protocol error”.
Measurement When BSC sends a "STATUS" message due to “protocol error”,
Point this counter increments.
Unit Times

C901340021
Definition Number of status messages sent with Processor overload
Description BSC sends the status message to SGSN to indicate that
abnormality occurs. This counter counts the number of BSC's
sending this message due to “processor overload”.
Measurement When BSC sends a "STATUS" message due to “processor
Point overload”, this counter increments.
Unit Times

C901340022
Definition Number of status messages received with BVCI Unknown
Description BSC sends the status message to SGSN to indicate that
abnormality occurs. This counter counts the number of BSC's
receiving this message due to “BVCI Unknown”.
Measurement When BSC receives a "STATUS" message due to “BVCI
Point Unknown”, this counter increments.
Unit Times

70 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - GB Message on IPGB HOST Measurement

C901340023
Definition Number of status messages received with cell service congestion
Description SGSN sends the status message to BSC to indicate that
abnormality occurs. This counter counts the number of BSC's
receiving this message due to “cell service congestion”.
Measurement When BSC receives a "STATUS" message due to “cell service
Point congestion”, this counter increments.
Unit Times

C901340024
Definition Number of status messages received with protocol error
Description SGSN sends the status message to BSC to indicate that
abnormality occurs. This counter counts the number of BSC's
receiving this message due to “protocol error”.
Measurement When BSC receives a "STATUS" message due to “protocol error”,
Point this counter increments.
Unit Times

C901340025
Definition Number of status messages received with processor overload
Description BSC sends the status message to SGSN to indicate that
abnormality occurs. This counter counts the number of BSC's
receiving this message due to “processor overload”.
Measurement When BSC receives a "STATUS" message due to “processor
Point overload”, this counter increments.
Unit Times

C901340026
Definition Number of DOWNLOAD-BSS-PFC messages sent by BSC
Description BSC sends the DOWNLOAD-BSS-PFC message to request SGSN
to initiate the CREATE-BSS-PFC process. This counter counts the
number of BSC's sending this message.
Measurement When BSC sends the “DOWNLOAD-BSS-PFC” message, this
Point counter increments. The measurement point is A1, as shown in
Figure 46.

Confidential and Proprietary Information of ZTE CORPORATION 71


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

FIGURE 46 – CRE ATE-BS S-PFC PROCESS

Unit Times

C901340027
Definition Number of BVCCREATE-BSS-PFC messages received by BSC
Description SGSN sends the CREATE-BSS-PFC message to request BSC to
create or modify a packet flow control context. This counter
counts the number of BSC's receiving this message.
Measurement When BSC receives a “CREATE-BSS-PFC” message, this counter
Point increments. The measurement point is A2, as shown in Figure 46.
Unit Times

C901340028
Definition Number of CREATE-BSS-PFC-ACK messages sent by BSC
Description BSC sends the CREATE-BSS-PFC-ACK message to acknowledge
the request of SGSN creating or modifying a packet flow control
context. This counter counts the number of BSC's sending this
message.
Measurement When BSC sends a CREATE-BSS-PFC-ACK message, this counter
Point increments. The measurement point is A3, as shown in Figure 46.
Unit Times

C901340029
Definition Number of CREATE-BSS-PFC-NACK messages sent by BSC
Description BSC sends the CREATE-BSS-PFC-NACK message to deny the
request of SGSN creating or modifying a packet flow control
context. This counter counts the number of BSC's sending this
message.

72 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - GB Message on IPGB HOST Measurement

Measurement When BSC sends a CREATE-BSS-PFC-NACK message, this


Point counter increments. The measurement point is A4, as shown in
Figure 46.
Unit Times

C901340030
Definition Number of MODIFY-BSS-PFC messages sent by BSC
Description BSC sends the MODIFY-BSS-PFC message to SGSN to request
for modifying the packet flow control context. This counter
counts the number of BSC's sending this message.
Measurement When BSC sends the “MODIFY-BSS-PFC” message, this counter
Point increments. The measurement point is A1, as shown in Figure 47.

FIGURE 47 – MODIFY-BSS-PFC PROCESS

Unit Times

C901340031
Definition Number of MODIFY-BSS-PFC-ACK messages received by BSC
Description SGSN sends the MODIFY-BSS-PFC-ACK message to BSC to
confirm the modification of packet flow control context. This
counter counts the number of BSC's receiving this message.
Measurement When BSC receives a MODIFY-BSS-PFC-ACK message, this
Point counter increments. The measurement point is A2, as shown in
Figure 47.
Unit Times

C901340032
Definition Number of DELETE-BSS-PFC messages received by BSC
Description SGSN sends the DELETE-BSS-PFC message to request BSC to
delete a packet flow control context. This counter counts the
number of BSC's receiving this message.

Confidential and Proprietary Information of ZTE CORPORATION 73


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Measurement When BSC receives a DELETE-BSS-PFC message, this counter


Point increments. The measurement point is A1, as shown in Figure 48.

FIGURE 48 – DELETE-BSS-PFC PROCESS

BSC SGSN
DELETE-BSS-PFC

A1
DELETE-BSS-PFC-ACK

A2

Unit Times

C901340033
Definition Number of DELETE-BSS-PFC-ACK messages sent by BSC
Description BSC sends the DELETE-BSS-PFC-ACK message to SGSN to
confirm the deletion of specified packet flow control context. This
counter counts the number of BSC's sending this message.
Measurement When BSC sends a DELETE-BSS-PFC-ACK message, this counter
Point increments. The measurement point is A2, as shown in Figure 48.
Unit Times

C901340034
Definition Number of DELETE-BSS-PFC-REQ messages received by BSC
Description This counter is not used for the time being.

74 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6

NSE on IPGB HOST


Measurement

The NSE measurement on IPGB HOST takes a single NSE as the


measurement unit. It performs statistics for paging message,
status indication message, and signaling BVC resetting message,
etc. This chapter introduces the meaning, usage, and
measurement point of counters of NSE measurement on IPGB
HOST.

Overview
The NSE measurement on IPGB HOST takes a single NSE as the
measurement entity. It performs statistics for paging message,
status indication message, and signaling BVC resetting message
received by NSE at BSS.
Statistic unit in this measurement is the single NSE.

NSE on IPGB HOST Measurement


Counter Index
Table 10 lists counters related to NSE on IPGB HOST
measurement.

TABLE 10 – COUNTERS OF NSE MEASUREMENT ON IPGB HOST

Counter ID What It Counts


C901350001 Number of CS Paging received by BSS
C901350002 Number of PS Paging received by BSS
C901350003 Number of SUSPEND message sent
C901350004 Number of SUSPEND-ACK message received

Confidential and Proprietary Information of ZTE CORPORATION 75


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Counter ID What It Counts


C901350005 Number of SUSPEND-NACK message received
C901350006 Number of RESUME message sent
C901350007 Number of RESUME-ACK message received
C901350008 Number of RESUME-NACK message received
C901350009 Number of FLUSH-LL message received
C901350010 Number of FLUSH-LL-ACK message sent
C901350011 Number of LLC-DISCARDED message sent
C901350012 Number of BVC-BLOCK message sent
C901350013 Number of BVC_BLOCK_ACK message received
C901350014 Number of BVC-UNBLOCK message sent
C901350015 Number of BVC-UNBLOCK-ACK message received
C901350016 Number of BVC-RESET message sent
C901350017 Number of BVC-RESET message received
C901350018 Number of BVC-RESET-ACK message sent
C901350019 Number of BVC-RESET-ACK message received
Number of PERFORM– LOCATION-REQUEST
C901350020
message received
Number of PERFORM-LOCATION-RESPONSE
C901350021
message sent
Number of PERFORM-LOCATION-ABORT message
C901350022
received
C901350023 Number of POSITION-COMMAND message sent
C901350024 Number of POSITION-RESPONSE message received
C901350025 Number of status messages sent
C901350026 Number of status messages received
Number of status messages sent with BVCI
C901350027
Unknown
Number of status messages sent with cell service
C901350028
congestion
Number of status messages sent with protocol
C901350029
error
Number of status messages sent with processor
C901350030
overload
Number of status messages sent with semantically
C901350031
incorrect PDU
Number of status messages sent with invalid
C901350032
mandatory information element
Number of status messages sent with missing
C901350033
mandatory IE
Number of status messages sent with missing
C901350034
conditional IE

76 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - NSE on IPGB HOST Measurement

Counter ID What It Counts


Number of status messages sent with unexpected
C901350035
conditional IE
Number of status messages sent with conditional
C901350036
IE error
Number of status messages sent with protocol
C901350037
status incompatible error
Number of status messages received with BVCI
C901350038
unknown
Number of status messages received with cell
C901350039
service congestion
Number of status messages received with protocol
C901350040
error
Number of status messages received with
C901350041
processor overload
Number of status messages received with BVC
C901350042
blocking
Number of status messages received with
C901350043
semantically incorrect PDU
Number of status messages received with invalid
C901350044
mandatory IE
Number of status messages received with missing
C901350045
mandatory IE
Number of status messages received with missing
C901350046
conditional IE
Number of status messages received with
C901350047
unexpected conditional IE
Number of status messages received with
C901350048
conditional IE error
Number of status messages received with protocol
C901350049
status incompatible error
Number of status messages received with SGSN
C901350050
congestion

C901350001
Definition Number of CS Paging received by BSS
Description This counter counts the number of PAGING CS messages
received by NSE at BSC from SGSN.
Usage The counter is used to find out the frequency of SGSN's CS
paging to MS.
Measurement When BSS receives a message of which the type is
Point GB_PAGING_CS, the counter increments.

Confidential and Proprietary Information of ZTE CORPORATION 77


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Unit Times

C901350002
Definition Number of PS Paging received by BSS
Description This counter counts the number of PAGING PS messages
received by NSE at BSC from SGSN.
Usage The counter is used to find out the frequency of SGSN's PS
paging to MS.
Measurement When BSS receives a message of which the type is
Point GB_PAGING_PS, the counter increments.
Unit Times

C901350003
Definition Number of SUSPEND message sent
Description When BSS receives the suspending GPRS service message from
MS, BSS will send the SUSPEND message to SGSN. This counter
counts the number of sending SUSPEND message from NSE.
Usage The counter is used to find out the frequency of MS's terminating
GPRS service.
Measurement When BSS sends the SUSPEND message, the counter increments.
Point

Unit Times

C901350004
Definition Number of SUSPEND-ACK message received
Description When SGSN receives the SUSPEND message from BSS, SGSN
will send the SUSPEND_ACK message to BSS. This counter
counts the number of SUSPEND_ACK messages received by NSE.
Usage The counter is used to find out cases in which SGSN has
response when MS requests for terminating GPRS service.
Measurement When BSS sends the SUSPEND_ACK message, the counter
Point increments.
Unit Times

78 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - NSE on IPGB HOST Measurement

C901350005
Definition Number of SUSPEND-NACK message received
Description When SGSN receives the SUSPEND message from BSS, it checks
the SUSPEND message content. If the message content is
incorrect or fault occurs at SGSN, SGSN will send the
SUSPEND_NACK message to BSS. This counter counts the
number of SUSPEND_NACK messages received by NSE.
Usage The counter is used to find out cases in which SGSN has no
response when MS requests for terminating GPRS service.
Measurement When BSS sends the SUSPEND_NACK message, the counter
Point increments.
Unit Times

C901350006
Definition Number of RESUME message sent
Description When problems that cause MS to suspend disappear, BSS might
send the RESUME message to SGSN to notify it to resume GPRS
service of MS. This counter counts the number of sending
RESUME message by BSS.
Usage The counter is used to find out the frequency of MS's resuming
GPRS service.
Measurement When BSS sends the RESUME message, the counter increments.
Point

Unit Times

C901350007
Definition Number of RESUME-ACK message received
Description When SGSN receives the RESUME message from BSS, SGSN will
send the RESUME_ACK message to BSS. This counter counts the
number of RESUME_ACK messages received by NSE.
Usage The counter is used to find out causes due to which SGSN has
no response when MS requests for resuming GPRS service.
Measurement When BSS sends the RESUME_ACK message, the counter
Point increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 79


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901350008
Definition Number of RESUME-NACK message received
Description If the MS in the RESUME PDU message sent from BSS is not
found at SGSN, SGSN willl send the RESUME_NACK message to
BSS. This message contains the failure cause, that is, unknown
MS. At this moment, BSS will terminate the RESUME process
and ask MS to update routing area. This counter counts the
number of RESUME_NACK messages received by NSE.
Usage The counter is used to find out cases in which SGSN has no
response when MS requests for resuming GPRS service.
Measurement When BSS receives the RESUME_NACK message, the counter
Point increments.
Unit Times

C901350009
Definition Number of FLUSH-LL message received
Description When SGSN detects that a MS changes cell through cell update
or routing area update, SGSN will send the FLUSH_LL message
to the old BVC to initiate the cell update process on NSE. This
counter counts the number of FLUSH_LL messages received by
NSE.
Usage The counter is used to find out the frequency of MS's changing
cell.
Measurement When BSS receives the FLUSH_LL message, the counter
Point increments.
Unit Times

C901350010
Definition Number of FLUSH-LL-ACK message sent
Description When BSS receives the FLUSH_LL message from SGSN, BSS will
send the FLUSH_LL_ACK message to SGSN. This counter counts
the number of sending FLUSH_LL_ACK message from NSE.
Usage The counter is used to find out that, after MS changes cell,
whether the MS's LLC PDU buffer is deleted in the old cell or
moved to the new cell in the routing area.
Measurement When BSS sends the FLUSH_LL_ACK message, the counter
Point increments.
Unit Times

80 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - NSE on IPGB HOST Measurement

C901350011
Definition Number of LLC-DISCARDED message sent
Description When the LLC PDU stored in BSS is deleted, the
LLC_DISCARDED message is sent to SGSN. This counter counts
the number of sending LLC_DISCARDED message from NSE.
Usage The counter is used to find out the storage of LLC PDU in BSS.
Measurement When BSS sends the LLC_DISCARDED message, the counter
Point increments.
Unit Times

C901350012
Definition Number of BVC-BLOCK message sent
Description When BSS blocks a BVC, it will send the BVC_BLOCK message to
SGSN to start the timer T1. BSS will identify the blocked BVC
and stop sending uplink data of the BVC. Meanwhile, cells
associated with the BVC do not receive downlink data any more.
This counter counts the number of sending BVC_BLOCK message
from NSE.
Usage The counter is used to find out the frequency of BSS's
requesting to block BVC.
Measurement When BSS sends the BVC_BLOCK message, the counter
Point increments.
Unit Times

C901350013
Definition Number of BVC-BLOCK-ACK message received
Description When SGSN receives the BVC_BLOCK message from BSS, it
identifies the BVC to be blocked and stops sending data to the
BVC, and replies the BVC_BLOCK_ACK message to BSS. This
counter counts the number of BVC_BLOCK_ACK messages
received by NSE.
Usage The counter is used to find out cases when BVC is blocked.
Measurement When BSS receives the BVC_BLOCK_ACK message, the counter
Point increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 81


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901350014
Definition Number of BVC-UNBLOCK message sent
Description When BSS unblocks the blocked BVC, it will send the
BVC_UNBLOCK message to SGSN. This counter counts the
number of sending BVC_UNBLOCK message from NSE.
Usage The counter is used to find out the frequency of BSS's
requesting to unblock BVC.
Measurement When BSS sends the BVC_UNBLOCK message, the counter
Point increments.
Unit Times

C901350015
Definition Number of BVC-UNBLOCK-ACK message received
Description When SGSN receives the BVC_UNBLOCK message from BSS, it
identifies the BVC to be unblocked and replies the
BVC_UNBLOCK_ACK message to BSS. This counter counts the
number of BVC_UNBLOCK_ACK messages received by NSE.
Usage The counter is used to find out cases when BVC is unblocked.
Measurement When BSS receives the BVC_BLOCK_ACK message, the counter
Point increments.
Unit Times

C901350016
Definition Number of BVC-RESET message sent
Description This counter counts the number of PCU sending signaling BVC
resetting message through Gb interface.
Usage The counter is used to find out the frequency of requesting to
restart BVC due to BVC failure.
Measurement When NSE at BSC sends message of which the type is
Point BVC_RESET and BVCI is zero, the counter increments.
Unit Times

C901350017
Definition Number of BVC-RESET message received
Description This counter counts the number of PCU's receiving the signaling
BVC resetting message.

82 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - NSE on IPGB HOST Measurement

Usage The counter is used to find out cases when BVC is restarted.
Measurement When NSE at BSC receives message of which the type is
Point BVC_RESET and BVCI is zero, the counter increments.
Unit Times

C901350018
Definition Number of BVC-RESET-ACK message sent
Description When PCU receives the signaling BVC resetting message from
Gb interface, it replies the signaling BVC resetting
acknowledgement message. This counter counts the number of
NSE's sending signaling BVC resetting acknowledgement
message.
Usage The counter is used to find out cases of SGSN initializing BVC.
Measurement When NSE at BSC sends message of which the type is
Point BVC_RESET_ACK and BVCI is zero, the counter increments.
Unit Times

C901350019
Definition Number of BVC-RESET-ACK message received
Description Number of PCU's receiving the signaling BVC resetting
acknowledgement message. This counter counts the number of
NSE's receiving signaling BVC resetting acknowledgement
message.
Usage The counter is used to find out cases of BVC initialization.
Measurement When NSE at BSC receives message of which the type is
Point BVC_RESET_ACK and BVCI is zero, the counter increments.
Unit Times

C901350020
Definition Number of PERFORM–LOCATION-REQUEST message received
Description When SGSN receives the location request and BSS supports LCS,
SGSN will start the locating process and send
PERFORM_LOCATION_REQUEST message to BSS. This counter
counts the number of BSS's receiving the location request
message.
Usage The counter is used to find out the frequency of SGSN's sending
location request to BSS.

Confidential and Proprietary Information of ZTE CORPORATION 83


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Measurement When BSS receives the PERFORM_LOCATION_REQUEST


Point message, the counter increments.
Unit Times

C901350021
Definition Number of PERFORM_LOCATION_RESPONSE message sent
Description After BSS receives the PERFORM_LOCATION_REQUEST message,
it will send the location request to SMLC and wait for SMLC's
response, and then send the result in the
PERFORM_LOCATION_RESPONSE message to SGSN. This
counter counts the number of BSS's sending the location request
response message.
Usage The counter is used to find out BSS's response to the location
request from SGSN.
Measurement When BSS receives the PERFORM_LOCATION_REQUEST
Point message, the counter increments.
Unit Times

C901350022
Definition Number of PERFORM_LOCATION_ABORT message received
Description When SGSN initiates the location request before interruption
occurs, it sends the PERFORM_LOCATION_ABORT message to
BSS. This counter counts the number of BSS's receiving the
PERFORM_LOCATION_ABORT message.
Usage The counter is used to find out the frequency of SGSN's
terminating location towards BSS.
Measurement When BSS receives the PERFORM_LOCATION_REQUEST
Point message, the counter increments.
Unit Times

C901350023
Definition Number of POSITION_COMMAND message sent
Description BSS triggers the positioning command process by sending
POSITION_COMMAND message to SGSN. This process is valid
only when positioning a MS. This counter counts the number of
BSS's sending POSITION_COMMAND message.
Usage The counter is used to find out the frequency of BSS's
requesting to implement positioning command to SGSN.

84 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - NSE on IPGB HOST Measurement

Measurement When BSS sends the POSITION_COMMAND message, the


Point counter increments.
Unit Times

C901350024
Definition Number of POSITION_RESPONSE message received
Description When SGSN receives the TOM message, SGSN will send the
POSITION_RESPONSE message to BSS to trigger the position
response process. The TOM message is contained in LLC PDU,
and the LLC PDU contains the RRLP message of a MS. This
position response process is valid only when positioning a MS.
This counter counts the number of BSS's receiving the
POSITION_RESPONSE message.
Usage The counter is used to find out the frequency of SGSN's
requesting to implement positioning command to BSS.
Measurement When BSS receives the POSITION_RESPONSE message, the
Point counter increments.
Unit Times

C901350025
Definition Number of status messages sent
Description When NSE receives downlink BSSGP PDU, if there is any
abnormality, NSE will send the STATUS message to the opposite
end entity. The STATUS message sent indicates causes of the
abnormality: BVCI unknown, cell traffic congestion, Protocol
error, Processor overload, Semantically incorrect PDU, Invalid
mandatory information, Missing mandatory IE, or Missing
conditional IE. This counter counts the number of abnormality
that occurs.
Usage The counter is used to find out abnormality occurring when NSE
receives downlink BSSGP PDU.
Measurement When NSE at BSC sends message of which the type is STATUS
Point to the opposite end entity, the counter increments.
Unit Times

C901350026
Definition Number of status messages received
Description If the BSSGP PDU sent by NSE to SGSN is abnormal, NSE will
receive the STATUS message returned from the opposite end.
The STATUS message returned indicates causes of the

Confidential and Proprietary Information of ZTE CORPORATION 85


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

abnormality: BVCI unknown, cell traffic congestion, Protocol


error, Processor overload, Semantically incorrect PDU, Invalid
mandatory information, Missing mandatory IE, or Missing
conditional IE. This counter counts the number of STATUS
messages returned from SGSN.
Usage The counter is used to find out abnormality occurring when
SGSN receives downlink BSSGP PDU.
Measurement When NSE receives the STATUS message, the counter
Point increments.
Unit Times

C901350027
Definition Number of status messages sent with BVCI Unknown
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating "BVCI
unknown".
Usage The counter is used to find out the frequency of abnormality due
to "BVCI unknown" occurring when NSE receives downlink
BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to "BVCI
unknown", the counter increments.
Unit Times

C901350028
Definition Number of status messages sent with cell service congestion
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating "cell
traffic congestion".
Usage The counter is used to find out the frequency of abnormality due
to "cell traffic congestion" occurring when NSE receives downlink
BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to "cell
traffic congestion", the counter increments.
Unit Times

C901350029
Definition Number of status messages sent with protocol error

86 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - NSE on IPGB HOST Measurement

Description This counter counts the number of NSE's sending STATUS


message to opposite end entity, the message indicating
"Protocol error".
Usage The counter is used to find out the frequency of abnormality due
to "Protocol error" occurring when NSE receives downlink BSSGP
PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Protocol error", the counter increments.
Unit Times

C901350030
Definition Number of status messages sent with processor overload
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating
"Processor overload".
Usage The counter is used to find out the frequency of abnormality due
to "Processor overload" occurring when NSE receives downlink
BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Processor overload", the counter increments.
Unit Times

C901350031
Definition Number of status messages sent with semantically incorrect PDU
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating
"Semantically incorrect PDU".
Usage The counter is used to find out the frequency of abnormality due
to "Semantically incorrect PDU" occurring when NSE receives
downlink BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Semantically incorrect PDU", the counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 87


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901350032
Definition Number of status messages sent with invalid mandatory
information element
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating "Invalid
mandatory information".
Usage The counter is used to find out the frequency of abnormality due
to "Invalid mandatory information" occurring when NSE receives
downlink BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Invalid mandatory information", the counter increments.
Unit Times

C901350033
Definition Number of status messages sent with missing mandatory IE
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating "Missing
mandatory IE".
Usage The counter is used to find out the frequency of abnormality due
to "Missing mandatory IE" occurring when NSE receives
downlink BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Missing mandatory IE", the counter increments.
Unit Times

C901350034
Definition Number of status messages sent with missing conditional IE
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating "Missing
conditional IE".
Usage The counter is used to find out the frequency of abnormality due
to "Missing conditional IE" occurring when NSE receives
downlink BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Missing conditional IE", the counter increments.
Unit Times

88 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - NSE on IPGB HOST Measurement

C901350035
Definition Number of status messages sent with unexpected conditional IE
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating
"Unexpected conditional IE".
Usage The counter is used to find out the frequency of abnormality due
to "Unexpected conditional IE" occurring when NSE receives
downlink BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Unexpected conditional IE", the counter increments.
Unit Times

C901350036
Definition Number of status messages sent with conditional IE error
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating
"Conditional IE error".
Usage The counter is used to find out the frequency of abnormality due
to "Conditional IE error" occurring when NSE receives downlink
BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to
"Conditional IE error", the counter increments.
Unit Times

C901350037
Definition Number of status messages sent with protocol status
incompatible error
Description This counter counts the number of NSE's sending STATUS
message to opposite end entity, the message indicating "PDU
not compatible with the protocol state".
Usage The counter is used to find out the frequency of abnormality due
to "PDU not compatible with the protocol state" occurring when
NSE receives downlink BSSGP PDU.
Measurement When NSE sends the STATUS message to opposite end entity
Point and the message indicates that the abnormality is due to "PDU
not compatible with the protocol state", the counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 89


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901350038
Definition Number of status messages received with BVCI unknown
Description This counter counts the number of received STATUS messages
which indicate "BVCI unknown".
Usage The counter is used to find out the frequency of abnormality due
to "BVCI unknown" occurring when SGSN receives downlink
BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "BVCI
Point unknown", the counter increments.
Unit Times

C901350039
Definition Number of status messages received with cell service congestion
Description This counter counts the number of PCU's receiving STATUS
message from SGSN, the message indicating "cell traffic
congestion".
Usage The counter is used to find out the frequency of abnormality due
to "cell traffic congestion" occurring when SGSN receives
downlink BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "cell traffic
Point congestion", the counter increments.
Unit Times

C901350040
Definition Number of status messages received with protocol error
Description This counter counts the number of received STATUS messages
which indicate "Protocol error".
Usage The counter is used to find out the frequency of abnormality due
to "Protocol error" occurring when SGSN receives downlink
BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "Protocol
Point error", the counter increments.
Unit Times

C901350041
Definition Number of status messages received with processor overload

90 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - NSE on IPGB HOST Measurement

Description This counter counts the number of PCU's receiving STATUS


message from SGSN, the message indicating "Processor
overload".
Usage The counter is used to find out the frequency of abnormality due
to "Processor overload" occurring when SGSN receives downlink
BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "Processor
Point overload", the counter increments.
Unit Times

C901350042
Definition Number of status messages received with BVC blocking
Description This counter counts the number of PCU's receiving STATUS
message from SGSN, the message indicating "BVCI-blocked".
Usage The counter is used to find out the frequency of abnormality due
to "BVCI-blocked" occurring when SGSN receives downlink
BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "BVCI-
Point blocked", the counter increments.
Unit Times

C901350043
Definition Number of status messages received with semantically incorrect
PDU
Description This counter counts the number of received STATUS messages
which indicate "Semantically incorrect PDU".
Usage The counter is used to find out the frequency of abnormality due
to "Semantically incorrect PDU" occurring when SGSN receives
downlink BSSGP PDU.
Measurement When PCU receives STATUS message which indicates
Point "Semantically incorrect PDU", the counter increments.
Unit Times

C901350044
Definition Number of status messages received with invalid mandatory IE
Description This counter counts the number of received STATUS messages
which indicate "Invalid mandatory information".

Confidential and Proprietary Information of ZTE CORPORATION 91


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Usage The counter is used to find out the frequency of abnormality due
to "Invalid mandatory information" occurring when SGSN
receives downlink BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "Invalid
Point mandatory information", the counter increments.
Unit Times

C901350045
Definition Number of status messages received with missing mandatory IE
Description This counter counts the number of received STATUS messages
which indicate "Missing mandatory IE".
Usage The counter is used to find out the frequency of abnormality due
to "Missing mandatory IE" occurring when SGSN receives
downlink BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "Missing
Point mandatory IE", the counter increments.
Unit Times

C901350046
Definition Number of status messages received with missing conditional IE
Description This counter counts the number of received STATUS messages
which indicate "Missing conditional IE".
Usage The counter is used to find out the frequency of abnormality due
to "Missing conditional IE" occurring when SGSN receives
downlink BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "Missing
Point conditional IE", the counter increments.
Unit Times

C901350047
Definition Number of status messages received with unexpected
conditional IE
Description This counter counts the number of received STATUS messages
which indicate "Unexpected conditional IE".
Usage The counter is used to find out the frequency of abnormality due
to "Unexpected conditional IE" occurring when SGSN receives
downlink BSSGP PDU.

92 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - NSE on IPGB HOST Measurement

Measurement When PCU receives STATUS message which indicates


Point "Unexpected conditional IE", the counter increments.
Unit Times

C901350048
Definition Number of status messages received with conditional IE error
Description This counter counts the number of received STATUS messages
which indicate "Conditional IE error".
Usage The counter is used to find out the frequency of abnormality due
to "Conditional IE error" occurring when SGSN receives downlink
BSSGP PDU.
Measurement When PCU receives STATUS message which indicates
Point "Conditional IE error", the counter increments.
Unit Times

C901350049
Definition Number of status messages received with protocol status
incompatible error
Description This counter counts the number of received STATUS messages
which indicate "PDU not compatible with the protocol state".
Usage The counter is used to find out the frequency of abnormality due
to "PDU not compatible with the protocol state" occurring when
SGSN receives downlink BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "PDU not
Point compatible with the protocol state", the counter increments.
Unit Times

C901350050
Definition Number of status messages received with SGSN congestion
Description This counter counts the number of PCU's receiving STATUS
message from SGSN, the message indicating "SGSN congestion".
Usage The counter is used to find out the frequency of abnormality due
to "SGSN congestion" occurring when SGSN receives downlink
BSSGP PDU.
Measurement When PCU receives STATUS message which indicates "SGSN
Point congestion", the counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 93


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This page is intentionally blank.

94 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7

BSSMAP Message
Measurement

The BSSMAP message measurement performs statistics for the


number of BSSMAP messages that BSC generates, forwards, or
receives. This chapter introduces the meaning, usage, and
measurement point of BSSMAP message measurement counters.

Overview
The BSSMAP message measurement performs statistics for
various BSSMAP messages at A-interface. It is used to find out
the frequency of various BSSMAP messages transmitted at A-
interface. When BSC receives the correct BSSMAP message from
MSC, the counter counts. The measurement point is A, as shown
in Figure 49.

F I G U R E 4 9 – M E A S U R E M E N T P O I N T O F M S C S E N D I N G B S S M AP M E S S A G E T O
BSC

Before BSC sends the BSSMAP message to MSC, the counter


counts. The measurement point is A, as shown in Figure 50.

Confidential and Proprietary Information of ZTE CORPORATION 95


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

F I G U R E 5 0 – M E A S U R E M E N T P O I N T O F B S C S E N D I N G B S S M AP M E S S A G E T O
MSC

Statistic unit in this measurement is Control Main Processor


(CMP).

BSSMAP Message Measurement


Counter Index
Table 11 lists counters related to BSSMAP message
measurementt.

T A B L E 1 1 – B S S M AP M E S S A G E M E A S U R E M E N T C O U N T E R S

Counter ID What It Counts


C901360001 Number of ASSIGNMENT REQUEST messages
C901360002 Number of ASSIGNMENT COMPLETE messages
C901360003 Number of ASSIGNMENT FAILURE messages
C901360004 Number of RESOURCE REQUEST messages
C901360005 Number of RESOURCE INDICATION messages
C901360006 Number of PAGING messages
C901360007 Number of CIPHER MODE COMMAND messages
C901360008 Number of CIPHER MODE COMPLETE messages
C901360009 Number of CIPHER MODE REJECT messages
C901360010 Number of sent CLASSMARK UPDATE messages
C901360011 Number of received CLASSMARK UPDATE messages
C901360012 Number of QUEUING INDICATION messages
Number of COMPLETE LAYER 3 INFORMATION
C901360013
messages
C901360014 Number of CLASSMARK REQUEST messages
C901360015 Number of UP LOAD INDICATION messages
C901360016 Number of DL LOAD INDICATION messages
C901360017 Number of HANDOVER REQUEST messages
C901360018 Number of HANDOVER REQUIRED messages

96 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

Counter ID What It Counts


C901360019 Number of HANDOVER COMMAND messages
C901360020 Number of HANDOVER REQUEST ACK messages
C901360021 Number of HANDOVER COMPLETE messages
C901360022 Number of HANDOVER SUCCEEDED messages
Number of HANDOVER CANDIDATE ENQUIRE
C901360023
messages
Number of HANDOVER CANDIDATE RESPONSE
C901360024
messages
C901360025 Number of HANDOVER FAILURE messages
C901360026 Number of HANDOVER PERFORMED messages
Number of HANDOVER REQUIRED REJECT
C901360027
messages
C901360028 Number of HANDOVER DETECT messages
C901360029 Number of CLEAR COMMAND messages
C901360030 Number of CLEAR COMPLETE messages
C901360031 Number of CLEAR REQUEST messages
C901360032 Number of SAPI "N" REJECT messages
C901360033 Number of UL CONFUSION messages
C901360034 Number of DL CONFUSION messages
C901360035 Number of UL RESET messages
C901360036 Number of DL RESET messages
C901360037 Number of UL RESET ACKNOWLEDGE messages
C901360038 Number of DL RESET ACKNOWLEDGE messages
C901360039 Number of UL OVERLOAD messages
C901360040 Number of DL OVERLOAD messages
C901360041 Number of MSC INVOKE TRACE messages
C901360042 Number of sent BSS INVOKE TRACE messages
C901360043 Number of received BSS INVOKE TRACE messages
Number of sent CONNECTIONLESS INFORMATION
C901360044
messages
Number of received CONNECTIONLESS
C901360045
INFORMATION messages
C901360046 Number of SUSPEND messages
C901360047 Number of RESUME messages
C901360048 Number of Common ID messages
C901360049 Number of LSA INFORMATION messages
Number of PERFORM LOCATION REQUEST
C901360050
messages
C901360051 Number of PERFORM LOCATION RESPONSE

Confidential and Proprietary Information of ZTE CORPORATION 97


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Counter ID What It Counts


messages
C901360052 Number of PERFORM LOCATION ABORT messages
C901360053 Number of sent BLOCK messages
C901360054 Number of received BLOCK ACK messages
C901360055 Number of sent UNBLOCK messages
C901360056 Number of received UNBLOCK ACK messages
C901360057 Number of received BLOCK messages
C901360058 Number of sent BLOCK ACK messages
C901360059 Number of received UNBLOCK messages
C901360060 Number of sent UNBLOCK ACK messages
C901360061 Number of UL RESET CIRCUIT messages
C901360062 Number of DL RESET CIRCUIT messages
C901360063 Number of UL RESET CIRCUIT ACK messages
C901360064 Number of DL RESET CIRCUIT ACK messages
C901360065 Number of UL CIRCUIT GROUP BLOCK messages
C901360066 Number of DL CIRCUIT GROUP BLOCK messages
Number of UL CIRCUIT GROUP BLOCKING
C901360067
ACKNOWLEDGE messages
Number of DL CIRCUIT GROUP BLOCKING
C901360068
ACKNOWLEDGE messages
C901360069 Number of UL CIRCUIT GROUP UNBLOCK messages
C901360070 Number of DL CIRCUIT GROUP UNBLOCK messages
Number of UL CIRCUIT GROUP UNBLOCKING
C901360071
ACKNOWLEDGE messages
Number of DL CIRCUIT GROUP UNBLOCKING
C901360072
ACKNOWLEDGE messages
C901360073 Number of UL UNEQUIPPED CIRCUIT messages
C901360074 Number of DL UNEQUIPPED CIRCUIT messages
C901360075 Number of CHANGE CIRCUIT messages
C901360076 Number of CHANGE CIRCUIT ACK messages
C901360077 Number of HANDOVER PERFORMED ACK messages

C901360001
Definition Number of ASSIGNMENT REQUEST messages
Description For one paging, MSC sends a ASSIGNMENT REQUEST message
to BSS, requesting BSC to change the current channel to a TCH.

98 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

During the paging process, MSC can also change mode at radio
interface through the ASSIGNMENT REQUEST message. This
counter counts the number of assignment request messages in
A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of assignment
request messages transmitted at A-interface.
Measurement When BSC receives the ASSIGNMENT REQUEST message, the
Point counter increments. The measurement point is A, as shown in
Figure 51.

F I G U R E 5 1 – M E A S U R E M E N T P O I N T O F B S C R E C E I V I N G AS S I G N M E N T
REQUEST MESSAGE FROM MSC

BSC MSC

ASSIGNMENT REQUEST

Unit Times

C901360002
Definition Number of ASSIGNMENT COMPLETE messages
Description During the mode modification (assignment) flow, after BSC
receives the RR message ASSIGNMENT COMPLETE from Um
interface, it sends an ASSIGNMENT COMPLETE message of A-
interface BSSMAP protocol to MSC. This counter counts the
number of assignment completion messages in A-interface
BSSMAP messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of assignment
completion messages transmitted at A-interface.
Measurement When BSC sends the ASSIGNMENT COMPLETE message to MSC,
Point the counter increments. The measurement point is A, as shown
in Figure 52.

FIGURE 52 – MEASUREMENT POINT OF BSC SENDING ASSIGNMENT


COMPLETE MESSAGE TO MSC

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 99


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901360003
Definition Number of ASSIGNMENT FAILURE messages
Description This counter counts the number of assignment failure messages
in A-interface BSSMAP messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of assignment
failure messages transmitted at A-interface.
Measurement When BSC sends the ASSIGNMENT FAILURE message to MSC,
Point the counter increments. The measurement point is A, as shown
in Figure 53.

FIGURE 53 – MEASUREMENT POINT OF BSC SENDING ASSIGNMENT


F AILURE MESSAGE TO MSC

Unit Times

C901360004
Definition Number of RESOURCE REQUEST messages
Description MSC sends the RESOURCE REQUEST message to BSC, the
message indicating the mode of reporting resource condition to
BSC and relevant cell IDs. This counter counts the number of
resource request messages in A-interface BSSMAP messages
received by BSC.
Usage The counter is used to find out the frequency of resource request
messages transmitted at A-interface.
Measurement When BSC receives the RESOURCE REQUEST message, the
Point counter increments. The measurement point is A, as shown in
Figure 54.

FIGURE 54 – MEASUREMENT POINT OF MSC SENDING RESOURCE


REQUEST MESSAGE TO BSC

BSC MSC

RESOURCE REQUEST

Unit Times

100 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

C901360005
Definition Number of RESOURCE INDICATION messages
Description After BSC receives the RESOURCE REQUEST message from MSC,
it sends the RESOURCE INDICATION message to MSC according
to MSC's requirement. The message contains the current
resource usage of relevant cells. This counter counts the number
of resource indication messages in A-interface BSSMAP
messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of resource
indication messages transmitted at A-interface.
Measurement When BSC sends the RESOURCE INDICATION message to MSC,
Point the counter increments. The measurement point is A, as shown
in Figure 55.

FIGURE 55 – MEASUREMENT POINT OF BSC SENDING RESOURCE


INDICATION MESSAGE TO MSC

Unit Times

C901360006
Definition Number of PAGING messages
Description When MSC needs to page a MS, it sends a PAGING message to
BSC through A-interface. This counter counts the number of
paging messages in A-interface BSSMAP messages received by
BSC.
Usage The counter is used to find out the frequency of paging
messages transmitted at A-interface.
Measurement When BSC receives the PAGING message, the counter
Point increments. The measurement point is A, as shown in Figure 56.

FIGURE 56 – MEASUREMENT POINT OF MSC SENDING P AGING MESSAGE TO


BSC

BSC MSC

PAGING

Confidential and Proprietary Information of ZTE CORPORATION 101


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Unit Times

C901360007
Definition Number of CIPHER MODE COMMAND messages
Description When MSC decides to modify the cipher mode of channel, it
sends a CIPHER MODE COMMAND message to BSC through A-
interface. This counter counts the number of CIPHER MODE
COMMAND messages in A-interface BSSMAP messages received
by BSC.
Usage The counter is used to find out the frequency of CIPHER MODE
COMMAND messages transmitted at A-interface.
Measurement When BSC receives the CIPHER MODE COMMAND message, the
Point counter increments. The measurement point is A, as shown in
Figure 57.

FIGURE 57 – MEASUREMENT POINT OF MSC SENDING CIPHER MODE


COMM AND MESSAGE TO BSC

BSC MSC

CIPHER MODE COMMAND

Unit Times

C901360008
Definition Number of CIPHER MODE COMPLETE messages
Description After BSC receives the CIPHERing MODE COMPLETE message
(RR message at Um interface) from MS , it sends the CIPHER
MODE COMPLETE message at A-interface to MSC as response.
This counter counts the number of CIPHER MODE COMPLETE
messages in A-interface BSSMAP messages sent to MSC from
BSC.
Usage The counter is used to find out the frequency of CIPHER MODE
COMPLETE messages transmitted at A-interface.
Measurement When BSC sends the CIPHER MODE COMPLETE message to MSC,
Point the counter increments. The measurement point is A, as shown
in Figure 58.

102 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

FIGURE 58 – MEASUREMENT POINT OF BSC SENDING CIPHER MODE


COMPLETE MESSAGE TO MSC

Unit Times

C901360009
Definition Number of CIPHER MODE REJECT messages
Description After BSC receives the CIPHERing MODE REJECT message (RR
message at Um interface) from MS , it sends the CIPHER MODE
REJECT message at A-interface to MSC as response. This
counter counts the number of CIPHER MODE REJECT messages
in A-interface BSSMAP messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of CIPHER MODE
REJECT messages transmitted at A-interface.
Measurement When BSC sends the CIPHER MODE REJECT message to MSC,
Point the counter increments. The measurement point is A, as shown
in Figure 59.

FIGURE 59 – MEASUREMENT POINT OF BSC SENDING CIPHER MODE


REJECT MESSAGE TO MSC

Unit Times

C901360010
Definition Number of sent CLASSMARK UPDATE messages
Description MS notifies the network of its classmark through the RR
message CLASSMARK CHANGE. After BSC receives the message,
it sends the CLASSMARK UPDATE message to MSC, the message
containing relevant information in the CLASSMARK CHANGE
message. This counter counts the number of CLASSMARK
UPDATE messages in A-interface BSSMAP messages sent to MSC
from BSC.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 103


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

The counter is used to find out the sending frequency of


CLASSMARK UPDATE messages transmitted at A-interface.
Measurement When BSC sends the CLASSMARK UPDATE message to MSC, the
Point counter increments. The measurement point is A, as shown in
Figure 60.

FIGURE 60 – MEASUREMENT POINT OF BSC SENDING CL ASSM ARK


UPDATE MESSAGE TO MSC

Unit Times

C901360011
Definition Number of received CLASSMARK UPDATE messages
Description This counter counts the number of CLASSMARK UPDATE
messages in A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of receiving
CLASSMARK UPDATE messages transmitted at A-interface.
Measurement When BSC receives the CLASSMARK UPDATE message, the
Point counter increments. The measurement point is A, as shown in
Figure 61.

FIGURE 61 – MEASUREMENT POINT OF MSC SENDING CL ASSM ARK


UPDATE MESSAGE TO BSC

BSC MSC

CLASSMARK UPDATE

Unit Times

C901360012
Definition Number of QUEUING INDICATION messages
Description During the assignment process or handover resource allocation
process, if BSS fails to be allocated with radio channel, the
queuing mechanism is adopted. With this mechanism, the
channel request can be delayed and BSS waits for idle radio
channels. In this case, BSS needs to send a QUEUING

104 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

INDICAITON message to MSC. This counter counts the number


of QUEUING INDICATION messages in A-interface BSSMAP
messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of QUEUING
INDICATION messages transmitted at A-interface.
Measurement When BSC sends the QUEUING INDICATION message to MSC,
Point the counter increments. The measurement point is A, as shown
in Figure 62.

FIGURE 62 – MEASUREMENT POINT OF BSC SENDING QUEUING


INDICATION MESSAGE TO MSC

Unit Times

C901360013
Definition Number of COMPLETE LAYER 3 INFORMATION messages
Description This counter counts the number of COMPLETE LAYER 3
INFORMATION messages in A-interface BSSMAP messages sent
to MSC from BSC.
Usage The counter is used to find out the frequency of COMPLETE
LAYER 3 INFORMATION messages transmitted at A-interface.
Measurement When BSC sends the COMPLETE LAYER 3 INFORMATION
Point message to MSC, the counter increments. The measurement
point is A, as shown in Figure 63.

FIGURE 63 – MEASUREMENT POINT OF BSC SENDING COMPLETE LAYER 3


INFORM ATION MESSAGE TO MSC

Unit Times

C901360014
Definition Number of CLASSMARK REQUEST messages

Confidential and Proprietary Information of ZTE CORPORATION 105


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Description When MSC wants MS classmark information, it sends a


CLASSMARK REQUEST message to BSC. This counter counts the
number of CLASSMARK REQUEST messages in A-interface
BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of CLASSMARK
REQUEST messages transmitted at A-interface.
Measurement When BSC receives the CLASSMARK REQUEST message, the
Point counter increments. The measurement point is A, as shown in
Figure 64.

FIGURE 64 – MEASUREMENT POINT OF MSC SENDING CL ASSM ARK


REQUEST MESSAGE TO BSC

BSC MSC

CLASSMARK REQUEST

Unit Times

C901360015
Definition Number of UP LOAD INDICATION messages
Description According to certain principle, such as reporting periodically or
reporting when triggered by threshold being exceeded, BSC
reports the current load of cells under it to MSC. After MSC
receives the message, it forwards the message to other relevant
BSCs. This counter counts the number of load indication
messages in A-interface BSSMAP messages sent to MSC from
BSC.
Usage The counter is used to find out the frequency of uplink load
indication messages transmitted at A-interface.
Measurement When BSC sends the LOAD INDICATION message to MSC, the
Point counter increments. The measurement point is A, as shown in
Figure 65.

FIGURE 65 – MEASUREMENT POINT OF BSC SENDING LO AD INDICATION


MESSAGE TO MSC

Unit Times

106 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

C901360016
Definition Number of DL LOAD INDICATION messages
Description This counter counts the number of load indication messages in
A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of downlink load
indication messages transmitted at A-interface.
Measurement When BSC receives the LOAD INDICATION message, the counter
Point increments. The measurement point is A, as shown in Figure 66.

FIGURE 66 – MEASUREMENT POINT OF MSC SENDING LO AD INDICATION


MESSAGE TO BSC

BSC MSC

LOAD INDICATION

Unit Times

C901360017
Definition Number of HANDOVER REQUEST messages
Description MSC sends a HANDOVER REQUEST message to the target BSS
to request channel resource for handover. This counter counts
the number of handover request messages in A-interface
BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of handover
request messages transmitted at A-interface.
Measurement When BSC receives the HANDOVER REQUEST message, the
Point counter increments. The measurement point is A, as shown in
Figure 67.

FIGURE 67 – MEASUREMENT POINT OF MSC SENDING H ANDOVER


REQUEST MESSAGE TO BSC

BSC MSC

HANDOVER REQUEST

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 107


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901360018
Definition Number of HANDOVER REQUIRED messages
Description When BSC decides to initiate an inter-BSC handover, it sends a
HANDOVER REQUIRED message to the MSC to which it belongs,
the message containing information of the target cell of
handover. This counter counts the number of HANDOVER
REQUIRED messages in A-interface BSSMAP messages sent to
MSC from BSC.
Usage The counter is used to find out the frequency of HANDOVER
REQUIRED messages transmitted at A-interface.
Measurement When BSC sends the HANDOVER REQUIRED message to MSC,
Point the counter increments. The measurement point is A1, as shown
in Figure 68.

FIGURE 68 – INTER-BSC HANDOVER PROCESS INITIATED BY BSC

BSC(Source) MSC BSC(Target)

A1
HANDOVER REQUIRED
HANDOVER REQUEST
A2
A3
HANDOVER REQUEST ACK
HANDOVER COMMAND
A5
A4
HANDOVER COMPLETE
HANDOVER SUCCEEDED
A6

Unit Times

C901360019
Definition Number of HANDOVER COMMAND messages
Description When BSC decides to initiate an inter-BSC handover, it sends a
HANDOVER REQUIRED message to the MSC to which it belongs,
the message containing information of the target cell of
handover. If MSC decides to perform handover and successfully
establishes channel at the target BSC, it sends the HANDOVER
COMMAND message as response. This counter counts the
number of HANDOVER COMMAND messages in A-interface
BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of HANDOVER
COMMAND messages transmitted at A-interface.

108 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

Measurement When BSC receives the HANDOVER COMMAND message, the


Point counter increments. The measurement point is A4, as shown in
Figure 68.
Unit Times

C901360020
Definition Number of HANDOVER REQUEST ACK messages
Description MSC sends a HANDOVER REQUEST message to the target BSS
to request channel resource for handover. If the target BSS
successfully allocates and activates channel, then BSC puts a
Um interface RR message HANDOVER COMMAND in the
HANDOVER REQUEST ACK message and returns the message to
MSC. This counter counts the number of HANDOVER REQUEST
ACK messages in A-interface BSSMAP messages sent to MSC
from BSC.
Usage The counter is used to find out the frequency of HANDOVER
REQUEST ACK messages transmitted at A-interface.
Measurement When BSC sends the HANDOVER REQUEST ACK message to MSC,
Point the counter increments. The measurement point is A3, as shown
in Figure 68.
Unit Times

C901360021
Definition Number of HANDOVER COMPLETE messages
Description When MS successfully performs handover to the target BSC, it
sends a Um interface RR message HANDOVER COMPLETE to BSC.
BSC then sends a HANDOVER COMPLETE message to MSC. This
counter counts the number of HANDOVER COMPLETE messages
in A-interface BSSMAP messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of HANDOVER
COMPLETE messages transmitted at A-interface.
Measurement When BSC sends the HANDOVER COMPLETE message to MSC,
Point the counter increments. The measurement point is A5, as shown
in Figure 68.
Unit Times

C901360022
Definition Number of HANDOVER SUCCEEDED messages
Description If the inter-BSC handover succeeds, MSC sends the HANDOVER
SUCCEEDED message to the old BSC. This counter counts the

Confidential and Proprietary Information of ZTE CORPORATION 109


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

number of HANDOVER SUCCEEDED messages in A-interface


BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of HANDOVER
SUCCEEDED messages transmitted at A-interface.
Measurement When BSC receives the HANDOVER SUCCEEDED message, the
Point counter increments. The measurement point is A6, as shown in
Figure 68.
Unit Times

C901360023
Definition Number of HANDOVER CANDIDATE ENQUIRE messages
Description MSC sends a HANDOVER CANDIDATE ENQUIRY message to the
BSC to which the cell belongs. The message contains the
maximum number of handover requests that can be triggered
and candidate cells that can be used for handover. This counter
counts the number of HANDOVER CANDIDATE ENQUIRE
messages in A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of HANDOVER
CANDIDATE ENQUIRE messages transmitted at A-interface.
Measurement When BSC receives the HANDOVER CANDIDATE ENQUIRE
Point message, the counter increments. The measurement point is A1,
as shown in Figure 69.

FIGURE 69 – PROCESS OF MSC SENDING H ANDOVER C ANDID ATE


ENQUIRE MESSAGE TO BSC

Unit Times

C901360024
Definition Number of HANDOVER CANDIDATE RESPONSE messages
Description After BSC receives the HANDOVER CANDIDATE ENQUIRE
message, it initiates handover process for specified calls of the
cell, that is, BSC sends corresponding HANDOVER REQUIRED
messages to MSC. After all HANDOVER REQUIRED messages are
sent, BSC notifies MSC of the number of triggered handover
through the HANDOVER CANDIDATE RESPONSE message.

110 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

This counter counts the number of HANDOVER CANDIDATE


RESPONSE messages in A-interface BSSMAP messages sent to
MSC from BSC.
Usage The counter is used to find out the frequency of HANDOVER
CANDIDATE RESPONSE messages transmitted at A-interface.
Measurement When BSC sends the HANDOVER CANDIDATE RESPONSE
Point message to MSC, the counter increments. The measurement
point is A2, as shown in Figure 69.
Unit Times

C901360025
Definition Number of HANDOVER FAILURE messages
Description This counter counts the number of HANDOVER FAILURE
messages in A-interface BSSMAP messages sent to MSC from
BSC.
Usage The counter is used to find out the frequency of HANDOVER
FAILURE messages transmitted at A-interface.
Measurement When BSC sends the HANDOVER FAILURE message to MSC, the
Point counter increments. The measurement point is A, as shown in
Figure 70.

FIGURE 70 – MEASUREMENT POINT OF BSC SENDING H ANDOVER F AILURE


MESSAGE TO MSC

Unit Times

C901360026
Definition Number of HANDOVER PERFORMED messages
Description After BSC performs a handover (intra-cell or inter-cell) within
itself, it sends a HANDOVER PERFORMED messge to MSC. This
counter counts the number of HANDOVER PERFORMED
messages in A-interface BSSMAP messages sent to MSC from
BSC.
Usage The counter is used to find out the frequency of HANDOVER
PERFORMED messages transmitted at A-interface.

Confidential and Proprietary Information of ZTE CORPORATION 111


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Measurement When BSC sends the HANDOVER PERFORMED message to MSC,


Point the counter increments. The measurement point is A, as shown
in Figure 71.

FIGURE 71 – MEASUREMENT POINT OF BSC SENDING H ANDOVER


PERFORMED MESSAGE TO MSC

Unit Times

C901360027
Definition Number of HANDOVER REQUIRED REJECT messages
Description This counter counts the number of HANDOVER REQUIRED
REJECT messages in A-interface BSSMAP messages received by
BSC.
Usage The counter is used to find out the frequency of HANDOVER
REQUIRED REJECT messages transmitted at A-interface.
Measurement When BSC receives the HANDOVER REQUIRED REJECT message,
Point the counter increments. The measurement point is A, as shown
in Figure 72.

FIGURE 72 – MEASUREMENT POINT OF MSC SENDING H ANDOVER


REQUIRED REJECT MESSAGE TO BSC

BSC MSC

HANDOVER REQUIRED REJECT

Unit Times

C901360028
Definition Number of HANDOVER DETECT messages
Description This counter counts the number of HANDOVER DETECT
messages in A-interface BSSMAP messages sent to MSC from
BSC.
Usage The counter is used to find out the frequency of HANDOVER
DETECT messages transmitted at A-interface.

112 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

Measurement When BSC sends the HANDOVER DETECT message to MSC, the
Point counter increments. The measurement point is A, as shown in
Figure 73.

FIGURE 73 – MEASUREMENT POINT OF BSC SENDING H ANDOVER DETECT


MESSAGE TO MSC

Unit Times

C901360029
Definition Number of CLEAR COMMAND messages
Description MSC sends the CLEAR COMMAND message to BSC, asking BSC
to release the conneciton. This counter counts the number of
CLEAR COMMAND messages in A-interface BSSMAP messages
received by BSC.
Usage The counter is used to find out the frequency of CLEAR
COMMAND messages transmitted at A-interface.
Measurement When BSC receives the CLEAR COMMAND message, the counter
Point increments. The measurement point is A1, as shown in Figure 74.

FIGURE 74 – CLE AR PROCESS

Unit Times

C901360030
Definition Number of CLEAR COMPLETE messages
Description After BSC receives the CLEAR COMMAND message, it starts
corresponding release process and returns the CLEAR COMPLETE
message to MSC. This counter counts the number of CLEAR
COMPLETE messages in A-interface BSSMAP messages sent to
MSC from BSC.

Confidential and Proprietary Information of ZTE CORPORATION 113


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Usage The counter is used to find out the frequency of CLEAR


COMPLETE messages transmitted at A-interface.
Measurement When BSC sends the CLEAR COMPLETE message to MSC, the
Point counter increments. The measurement point is A2, as shown in
Figure 74.
Unit Times

C901360031
Definition Number of CLEAR REQUEST messages
Description BSC sends the CLEAR REQUEST message to MSC, asking MSC to
release the conneciton. This counter counts the number of
CLEAR REQUEST messages in A-interface BSSMAP messages
sent to MSC from BSC.
Usage The counter is used to find out the frequency of CLEAR REQUEST
messages transmitted at A-interface.
Measurement When BSC sends the CLEAR REQUEST message to MSC, the
Point counter increments. The measurement point is A, as shown in
Figure 75.

FIGURE 75 – MEASUREMENT POINT OF BSC SENDING CLE AR REQUEST


MESSAGE TO MSC

Unit Times

C901360032
Definition Number of SAPI "N" REJECT messages
Description This counter counts the number of SAPI "N" REJECT messages in
A-interface BSSMAP messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of SAPI "N" REJECT
messages transmitted at A-interface.
Measurement When BSC sends the SAPI "N" REJECT message to MSC, the
Point counter increments. The measurement point is A, as shown in
Figure 76.

114 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

F I G U R E 7 6 – M E A S U R E M E N T P O I N T O F B S C S E N D I N G S AP I " N " R E J E C T
MESSAGE TO MSC

Unit Times

C901360033
Definition Number of UL CONFUSION messages
Description When BSC receives the incorrect BSSMAP message from MSC, it
sends the CONFUSION message to MSC. This counter counts the
number of CONFUSION messages in A-interface BSSMAP
messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of uplink
CONFUSION messages transmitted at A-interface.
Measurement When BSC sends the CONFUSION message to MSC, the counter
Point increments. The measurement point is A, as shown in Figure 77.

FIGURE 77 – MEASUREMENT POINT OF BSC SENDING CONFUSION MESSAGE


TO MSC

Unit Times

C901360034
Definition Number of DL CONFUSION messages
Description When MSC receives the incorrect BSSMAP message from BSC, it
sends the CONFUSION message to BSC. This counter counts the
number of CONFUSION messages in A-interface BSSMAP
messages received by BSC.
Usage The counter is used to find out the frequency of downlink
CONFUSION messages transmitted at A-interface.
Measurement When BSC receives the CONFUSION message, the counter
Point increments. The measurement point is A, as shown in Figure 78.

Confidential and Proprietary Information of ZTE CORPORATION 115


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

FIGURE 78 – MEASUREMENT POINT OF MSC SENDING CONFUSION


MESSAGE TO BSC

BSC MSC

CONFUSION

Unit Times

C901360035
Definition Number of UL RESET messages
Description When BSC detects that it has serious global fault, it will send a
RESET message to MSC. This counter counts the number of
RESET messages in A-interface BSSMAP messages sent to MSC
from BSC.
Usage The counter is used to find out the frequency of uplink RESET
messages transmitted at A-interface.
Measurement When BSC sends the RESET message to MSC, the counter
Point increments. The measurement point is A1, as shown in Figure 79.

FIGURE 79 – UPLINK RESET PROCESS

Unit Times

C901360036
Definition Number of DL RESET messages
Description When MSC detects that it has serious global fault, it will send a
RESET message to BSC. This counter counts the number of
RESET messages in A-interface BSSMAP messages received by
BSC.
Usage The counter is used to find out the frequency of downlink RESET
messages transmitted at A-interface.
Measurement When BSC receives the RESET message, the counter increments.
Point The measurement point is A1, as shown in Figure 80.

116 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

FIGURE 80 – DOWNLINK RESET PROCESS

Unit Times

C901360037
Definition Number of UL RESET ACKNOWLEDGE messages
Description When MSC detects that it has serious global fault, it will send a
RESET message to BSC. After BSC receives the message, it
releases all calls and relevant information, and after a period of
time, it returns the RESET ACKNOWLEDGE message as response.
This counter counts the number of RESET ACKNOWLEDGE
messages in A-interface BSSMAP messages sent to MSC from
BSC.
Usage The counter is used to find out the frequency of uplink RESET
ACKNOWLEDGE messages transmitted at A-interface.
Measurement When BSC sends the RESET ACKNOWLEDGE message to MSC,
Point the counter increments. The measurement point is A2, as shown
in Figure 80.
Unit Times

C901360038
Definition Number of DL RESET ACKNOWLEDGE messages
Description When BSC detects that it has serious global fault, it will send a
RESET message to MSC. After MSC receives the message, it
releases all calls and relevant information, and after a period of
time, it returns the RESET ACKNOWLEDGE message as response.
This counter counts the number of RESET ACKNOWLEDGE
messages in A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of downlink RESET
ACKNOWLEDGE messages transmitted at A-interface.
Measurement When BSC receives the RESET ACKNOWLEDGE message, the
Point counter increments. The measurement point is A2, as shown in
Figure 79.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 117


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901360039
Definition Number of UL OVERLOAD messages
Description When BSC detects that its processor is overloaded or CCCH
(which is PCH actually) is overloaded, it will send the OVERLOAD
message to the MSC to which it belongs. If the overload problem
persists, BSC will send the OVERLOAD message to MSC
periodically. This counter counts the number of OVERLOAD
messages in A-interface BSSMAP messages sent to MSC from
BSC.
Usage The counter is used to find out the frequency of uplink
OVERLOAD messages transmitted at A-interface.
Measurement When BSC sends the OVERLOAD message to MSC, the counter
Point increments. The measurement point is A, as shown in Figure 81.

FIGURE 81 – MEASUREMENT POINT OF BSC SENDING OVERLO AD MESSAGE


TO MSC

Unit Times

C901360040
Definition Number of DL OVERLOAD messages
Description When MSC detects that its processor is overloaded, it will send
the OVERLOAD message to the BSC under it. If the overload
problem persists, MSC will send the OVERLOAD message to BSC
periodically. This counter counts the number of OVERLOAD
messages in A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of downlink
OVERLOAD messages transmitted at A-interface.
Measurement When BSC receives the OVERLOAD message, the counter
Point increments. The measurement point is A, as shown in Figure 82.

118 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

FIGURE 82 – MEASUREMENT POINT OF MSC SENDING OVERLO AD MESSAGE


TO BSC

BSC MSC

OVERLOAD

Unit Times

C901360041
Definition Number of MSC INVOKE TRACE messages
Description When MSC needs to generate tracing records of specified calls
for BSC, it will send a MSC INVOKE TRACE message to the
corresponding BSC to trigger tracing actions. This counter
counts the number of MSC INVOKE TRACE messages in A-
interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of MSC INVOKE
TRACE messages transmitted at A-interface.
Measurement When BSC receives the MSC INVOKE TRACE message, the
Point counter increments. The measurement point is A, as shown in
Figure 83.

FIGURE 83 – MEASUREMENT POINT OF MSC SENDING MSC INVOKE TR ACE


MESSAGE TO BSC

BSC MSC

MSC INVOKE TRACE

Unit Times

C901360042
Definition Number of sent BSS INVOKE TRACE messages
Description When BSC needs to generate tracing records of specified calls
for MSC, it will send a BSS INVOKE TRACE message to the
corresponding MSC to trigger tracing actions. This counter
counts the number of BSS INVOKE TRACE messages in A-
interface BSSMAP messages sent by BSC.
Usage The counter is used to find out the frequency of sending BSS
INVOKE TRACE messages transmitted at A-interface.

Confidential and Proprietary Information of ZTE CORPORATION 119


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Measurement When BSC sends the BSS INVOKE TRACE message to MSC, the
Point counter increments. The measurement point is A, as shown in
Figure 84.

FIGURE 84 – MEASUREMENT POINT OF BSC SENDING BSS INVOKE TR ACE


MESSAGE TO MSC

Unit Times

C901360043
Definition Number of received BSS INVOKE TRACE messages
Description This counter counts the number of BSS INVOKE TRACE
messages in A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of receiving BSS
INVOKE TRACE messages transmitted at A-interface.
Measurement When BSC receives the BSS INVOKE TRACE message, the
Point counter increments. The measurement point is A, as shown in
Figure 85.

FIGURE 85 – MEASUREMENT POINT OF MSC SENDING BSS INVOKE TR ACE


MESSAGE TO BSC

BSC MSC

BSS INVOKE TRACE

Unit Times

C901360044
Definition Number of sent CONNECTIONLESS INFORMATION messages
Description This counter counts the number of CONNECTIONLESS
INFORMATION messages in A-interface BSSMAP messages sent
by BSC.
Usage The counter is used to find out the frequency of sending
CONNECTIONLESS INFORMATION messages transmitted at A-
interface.

120 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

Measurement When BSC sends the CONNECTIONLESS INFORMATION message


Point to MSC, the counter increments. The measurement point is A, as
shown in Figure 86.

FIGURE 86 – MEASUREMENT POINT OF BSC SENDING CONNECTIONLESS


INFORM ATION MESSAGE TO MSC

Unit Times

C901360045
Definition Number of received CONNECTIONLESS INFORMATION messages
Description This counter counts the number of CONNECTIONLESS
INFORMATION messages in A-interface BSSMAP messages
received by BSC.
Usage The counter is used to find out the frequency of receiving
CONNECTIONLESS INFORMATION messages transmitted at A-
interface.
Measurement When BSC receives the CONNECTIONLESS INFORMATION
Point message, the counter increments. The measurement point is A,
as shown in Figure 87.

FIGURE 87 – MEASUREMENT POINT OF MSC SENDING CONNECTIONLESS


INFORM ATION MESSAGE TO BSC

BSC MSC

CONNECTIONLESS INFORMATION

Unit Times

C901360046
Definition Number of SUSPEND messages
Description When BSC detects that congestion occurs at radio interface, it
sends a SUSPEND message to MSC, asking MSC to stop sending
DTAP message that contains PDSS1 protocol layer 3. This
counter counts the number of SUSPEND messages in A-interface
BSSMAP messages sent to MSC from BSC.

Confidential and Proprietary Information of ZTE CORPORATION 121


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Usage The counter is used to find out the frequency of SUSPEND


messages transmitted at A-interface.
Measurement When BSC sends the SUSPEND message to MSC, the counter
Point increments. The measurement point is A, as shown in Figure 88.

FIGURE 88 – MEASUREMENT POINT OF BSC SENDING SUSPEND MESSAGE


TO MSC

Unit Times

C901360047
Definition Number of RESUME messages
Description When BSC detects that congestion occurs at radio interface, it
sends a RESUME message to MSC, asking MSC to resume
sending DTAP message that contains PDSS1 protocol layer 3.
This counter counts the number of RESUME messages in A-
interface BSSMAP messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of RESUME
messages transmitted at A-interface.
Measurement When BSC sends the RESUME message to MSC, the counter
Point increments. The measurement point is A, as shown in Figure 89.

FIGURE 89 – MEASUREMENT POINT OF BSC SENDING RESUME MESSAGE TO


MSC

Unit Times

C901360048
Definition Number of Common ID messages
Description This counter counts the number of Common ID messages in A-
interface BSSMAP messages received by BSC.
Usage

122 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

The counter is used to find out the frequency of Common ID


messages transmitted at A-interface.
Measurement When BSC receives the Common ID message, the counter
Point increments. The measurement point is A, as shown in Figure 90.

FIGURE 90 – MEASUREMENT POINT OF MSC SENDING COMMON ID MESSAGE


TO BSC

BSC MSC

Common ID

Unit Times

C901360049
Definition Number of LSA INFORMATION messages
Description MSC may send a LSA INFORMATION message to BSC for a
certain call. This message contains a Localised Service Area (LSA)
list and relevant properties of each LSA, such as the priority.
This counter counts the number of LSA INFORMATION messages
in A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of LSA
INFORMATION messages transmitted at A-interface.
Measurement When BSC receives the LSA INFORMATION message, the
Point counter increments. The measurement point is A, as shown in
Figure 91.

FIGURE 91 – MEASUREMENT POINT OF MSC SENDING LS A INFORMATION


MESSAGE TO BSC

BSC MSC

LSA INFORMATION

Unit Times

C901360050
Definition Number of PERFORM LOCATION REQUEST messages
Description This counter counts the number of PERFORM LOCATION
REQUEST messages in A-interface BSSMAP messages received
by BSC.

Confidential and Proprietary Information of ZTE CORPORATION 123


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Usage The counter is used to find out the frequency of PERFORM


LOCATION REQUEST messages transmitted at A-interface.
Measurement When BSC receives the PERFORM LOCATION REQUEST message,
Point the counter increments. The measurement point is A1, as shown
in Figure 92.

FIGURE 92 – PROCESS OF MSC SENDING PERFORM LOC ATION RE QUEST


MESSAGE TO BSC

Unit Times

C901360051
Definition Number of PERFORM LOCATION RESPONSE messages
Description This counter counts the number of PERFORM LOCATION
RESPONSE messages in A-interface BSSMAP messages sent to
MSC from BSC.
Usage The counter is used to find out the frequency of PERFORM
LOCATION RESPONSE messages transmitted at A-interface.
Measurement When BSC sends the PERFORM LOCATION RESPONSE message
Point to MSC, the counter increments. The measurement point is A2,
as shown in Figure 92.
Unit Times

C901360052
Definition Number of PERFORM LOCATION ABORT messages
Description This counter counts the number of PERFORM LOCATION ABORT
messages in A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of PERFORM
LOCATION ABORT messages transmitted at A-interface.
Measurement When BSC receives the PERFORM LOCATION ABORT message,
Point the counter increments. The measurement point is A, as shown
in Figure 93.

124 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

FIGURE 93 – MEASUREM ENT POINT OF MSC SENDING PERFORM LOC ATION


ABORT MESSAGE TO BSC

BSC MSC

PERFORM LOCATION ABORT

Unit Times

C901360053
Definition Number of sent BLOCK messages
Description When BSC decides to block a terrestrial circuit of A-interface, it
sends a BLOCK message to MSC. This counter counts the
number of BLOCK messages in A-interface BSSMAP messages
sent to MSC from BSC.
Usage The counter is used to find out the frequency of sending BLOCK
messages transmitted at A-interface.
Measurement When BSC sends the BLOCK message to MSC, the counter
Point increments. The measurement point is A1, as shown in Figure 94.

FIGURE 94 – PROCESS OF BSC SENDING BLOCK MESSAGE TO MSC

Unit Times

C901360054
Definition Number of received BLOCK ACK messages
Description When BSC decides to block a terrestrial circuit of A-interface, it
sends a BLOCK message to MSC. MSC performs appropriate
handling and returns a BLOCK ACK message as response. This
counter counts the number of BLOCK ACK messages in A-
interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of receiving BLOCK
ACK messages transmitted at A-interface.

Confidential and Proprietary Information of ZTE CORPORATION 125


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Measurement When BSC receives the BLOCK ACK message, the counter
Point increments. The measurement point is A2, as shown in Figure 94.
Unit Times

C901360055
Definition Number of sent UNBLOCK messages
Description When BSC decides to unblock a terrestrial circuit of A-interface,
it sends an UNBLOCK message to MSC. This counter counts the
number of UNBLOCK messages in A-interface BSSMAP messages
sent to MSC from BSC.
Usage The counter is used to find out the frequency of sending
UNBLOCK messages transmitted at A-interface.
Measurement When BSC sends the UNBLOCK message to MSC, the counter
Point increments. The measurement point is A1, as shown in Figure 95.

FIGURE 95 – PROCESS OF BSC SENDING UNBLOCK MESSAGE TO MSC

Unit Times

C901360056
Definition Number of received UNBLOCK ACK messages
Description When BSC decides to unblock a terrestrial circuit of A-interface,
it sends an UNBLOCK message to MSC. MSC performs
appropriate handling and returns an UNBLOCK ACK message as
response. This counter counts the number of UNBLOCK ACK
messages in A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of receiving
UNBLOCK ACK messages transmitted at A-interface.
Measurement When BSC receives the UNBLOCK ACK message, the counter
Point increments. The measurement point is A2, as shown in Figure 95.
Unit Times

126 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

C901360057
Definition Number of received BLOCK messages
Description When MSC decides to block a terrestrial circuit of A-interface, it
sends a BLOCK message to BSC. This counter counts the
number of BLOCK messages in A-interface BSSMAP messages
received by BSC.
Usage The counter is used to find out the frequency of receiving BLOCK
messages transmitted at A-interface.
Measurement When BSC receives the BLOCK message, the counter increments.
Point The measurement point is A1, as shown in Figure 96.

FIGURE 96 – PROCESS OF MSC SENDING BLOCK MESSAGE TO BSC

Unit Times

C901360058
Definition Number of sent BLOCK ACK messages
Description When MSC decides to block a terrestrial circuit of A-interface, it
sends a BLOCK message to BSC. BSC performs appropriate
handling and returns a BLOCK ACK message as response. This
counter counts the number of BLOCK ACK messages in A-
interface BSSMAP messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of sending BLOCK
ACK messages transmitted at A-interface.
Measurement When BSC sends the BLOCK ACK message to MSC, the counter
Point increments. The measurement point is A2, as shown in Figure 96.
Unit Times

C901360059
Definition Number of received UNBLOCK messages
Description When MSC decides to unblock a terrestrial circuit of A-interface,
it sends a UNBLOCK message to BSC. This counter counts the
number of UNBLOCK messages in A-interface BSSMAP messages
received by BSC.

Confidential and Proprietary Information of ZTE CORPORATION 127


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Usage The counter is used to find out the frequency of receiving


UNBLOCK messages transmitted at A-interface.
Measurement When BSC receives the UNBLOCK message, the counter
Point increments. The measurement point is A1, as shown in Figure 97.

FIGURE 97 – PROCESS OF MSC SENDING UNBLOCK MESSAGE TO BSC

Unit Times

C901360060
Definition Number of sent UNBLOCK ACK messages
Description When MSC decides to unblock a terrestrial circuit of A-interface,
it sends a UNBLOCK message to BSC. BSC performs appropriate
handling and returns an UNBLOCK ACK message as response.
This counter counts the number of UNBLOCK ACK messages in
A-interface BSSMAP messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of sending
UNBLOCK ACK messages transmitted at A-interface.
Measurement When BSC sends the UNBLOCK ACK message to MSC, the
Point counter increments. The measurement point is A2, as shown in
Figure 97.
Unit Times

C901360061
Definition Number of UL RESET CIRCUIT messages
Description When BSC detects that an abnormal SCCP connection release
causes a circuit to become idle, it sends a RESET CIRCUIT
message to MSC. This counter counts the number of RESET
CIRCUIT messages in A-interface BSSMAP messages sent to
MSC from BSC.
Usage The counter is used to find out the frequency of uplink RESET
CIRCUIT messages transmitted at A-interface.
Measurement When BSC sends the RESET CIRCUIT message to MSC, the
Point counter increments. The measurement point is A1, as shown in
Figure 98.

128 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

FIGURE 98 – PROCESS OF BSC SENDING RESET CIRCUIT MESSAGE TO


MSC

Unit Times

C901360062
Definition Number of DL RESET CIRCUIT messages
Description When MSC detects that an abnormal SCCP connection release
causes a circuit to become idle, it sends a RESET CIRCUIT
message to BSC. This counter counts the number of RESET
CIRCUIT messages in A-interface BSSMAP messages received by
BSC.
Usage The counter is used to find out the frequency of downlink RESET
CIRCUIT messages transmitted at A-interface.
Measurement When BSC receives the RESET CIRCUIT message, the counter
Point increments. The measurement point is A1, as shown in Figure 99.

FIGURE 99 – PROCESS OF MSC SENDING RESET CIRCUIT MESSAGE TO


BSC

Unit Times

C901360063
Definition Number of UL RESET CIRCUIT ACK messages
Description When MSC detects that an abnormal SCCP connection release
causes a circuit to become idle, it sends a RESET CIRCUIT
message to BSC. After BSC receives the message, it clears
relevant calls and makes corresponding circuits to become idle,
and sends a RESET CIRCUIT ACK message to MSC. This counter

Confidential and Proprietary Information of ZTE CORPORATION 129


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

counts the number of RESET CIRCUIT ACK messages in A-


interface BSSMAP messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of uplink RESET
CIRCUIT ACK messages transmitted at A-interface.
Measurement When BSC sends the RESET CIRCUIT ACK message to MSC, the
Point counter increments. The measurement point is A2, as shown in
Figure 99.
Unit Times

C901360064
Definition Number of DL RESET CIRCUIT ACK messages
Description When BSC detects that an abnormal SCCP connection release
causes a circuit to become idle, it sends a RESET CIRCUIT
message to MSC. After MSC receives the message, it clears
relevant calls and makes corresponding circuits to become idle,
and sends a RESET CIRCUIT ACK message to BSC. This counter
counts the number of RESET CIRCUIT ACK messages in A-
interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of downlink RESET
CIRCUIT ACK messages transmitted at A-interface.
Measurement When BSC receives the RESET CIRCUIT ACK message, the
Point counter increments. The measurement point is A2, as shown in
Figure 98.
Unit Times

C901360065
Definition Number of UL CIRCUIT GROUP BLOCK messages
Description When BSC decides to block some terrestrial circuits of A-
interface and these terrestrial circuits can be described in one
message, BSC will send a CIRCUIT GROUP BLOCK message to
MSC. This counter counts the number of CIRCUIT GROUP BLOCK
messages in A-interface BSSMAP messages sent to MSC from
BSC.
Usage The counter is used to find out the frequency of uplink CIRCUIT
GROUP BLOCK messages transmitted at A-interface.
Measurement When BSC sends the CIRCUIT GROUP BLOCK message to MSC,
Point the counter increments. The measurement point is A1, as shown
in Figure 100.

130 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

FIGURE 100 – PROCESS OF BSC SENDING CIRCUIT GROUP BLOCK


MESSAGE TO MSC

Unit Times

C901360066
Definition Number of DL CIRCUIT GROUP BLOCK messages
Description When MSC decides to block some terrestrial circuits of A-
interface and these terrestrial circuits can be described in one
message, MSC will send a CIRCUIT GROUP BLOCK message to
BSC. This counter counts the number of CIRCUIT GROUP BLOCK
messages in A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of downlink
CIRCUIT GROUP BLOCK messages transmitted at A-interface.
Measurement When BSC receives the CIRCUIT GROUP BLOCK message, the
Point counter increments. The measurement point is A1, as shown in
Figure 101.

FIGURE 101 – PROCESS OF MSC SENDING CIRCUIT GROUP BLOCK


MESSAGE TO BSC

Unit Times

C901360067
Definition Number of UL CIRCUIT GROUP BLOCKING ACKNOWLEDGE
messages
Description When MSC decides to block some terrestrial circuits of A-
interface and these terrestrial circuits can be described in one
message, MSC will send a CIRCUIT GROUP BLOCK message to
BSC. After BSC performs appropriate handlings, it returns a

Confidential and Proprietary Information of ZTE CORPORATION 131


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

CIRCUIT GROUP BLOCKING ACKNOWLEDGE message as


response. This counter counts the number of CIRCUIT GROUP
BLOCKING ACKNOWLEDGE messages in A-interface BSSMAP
messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of uplink CIRCUIT
GROUP BLOCKING ACKNOWLEDGE messages transmitted at A-
interface.
Measurement When BSC sends the CIRCUIT GROUP BLOCKING
Point ACKNOWLEDGE message to MSC, the counter increments. The
measurement point is A2, as shown in Figure 101.
Unit Times

C901360068
Definition Number of DL CIRCUIT GROUP BLOCKING ACKNOWLEDGE
messages
Description When BSC decides to block some terrestrial circuits of A-
interface and these terrestrial circuits can be described in one
message, BSC will send a CIRCUIT GROUP BLOCK message to
MSC. After MSC performs appropriate handlings, it returns a
CIRCUIT GROUP BLOCKING ACKNOWLEDGE message as
response. This counter counts the number of CIRCUIT GROUP
BLOCKING ACKNOWLEDGE messages in A-interface BSSMAP
messages received by BSC.
Usage The counter is used to find out the frequency of downlink
CIRCUIT GROUP BLOCKING ACKNOWLEDGE messages
transmitted at A-interface.
Measurement When BSC receives the CIRCUIT GROUP BLOCKING
Point ACKNOWLEDGE message, the counter increments. The
measurement point is A2, as shown in Figure 100.
Unit Times

C901360069
Definition Number of UL CIRCUIT GROUP UNBLOCK messages
Description When BSC decides to unblock some terrestrial circuit of A-
interface, it sends a CIRCUIT GROUP UNBLOCK message to MSC.
This counter counts the number of CIRCUIT GROUP UNBLOCK
messages in A-interface BSSMAP messages sent to MSC from
BSC.
Usage The counter is used to find out the frequency of uplink CIRCUIT
GROUP UNBLOCK messages transmitted at A-interface.
Measurement When BSC sends the CIRCUIT GROUP UNBLOCK message to
Point MSC, the counter increments. The measurement point is A1, as
shown in Figure 102.

132 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

FIGURE 102 – PROCESS OF BSC SENDING CIRCUIT GROUP UNBLOCK


MESSAGE TO MSC

Unit Times

C901360070
Definition Number of DL CIRCUIT GROUP UNBLOCK messages
Description When MSC decides to unblock some terrestrial circuit of A-
interface, it sends a CIRCUIT GROUP UNBLOCK message to BSC.
This counter counts the number of CIRCUIT GROUP UNBLOCK
messages in A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of downlink
CIRCUIT GROUP UNBLOCK messages transmitted at A-interface.
Measurement When BSC receives the CIRCUIT GROUP UNBLOCK message, the
Point counter increments. The measurement point is A1, as shown in
Figure 103.

FIGURE 103 – PROCESS OF MSC SENDING CIRCUIT GROUP UNBLOCK


MESSAGE TO BSC

Unit Times

C901360071
Definition Number of UL CIRCUIT GROUP UNBLOCKING ACKNOWLEDGE
messages
Description When MSC decides to unblock some terrestrial circuit of A-
interface, it sends a CIRCUIT GROUP UNBLOCK message to BSC.
After BSC performs appropriate handlings, it returns a CIRCUIT
GROUP UNBLOCKING ACKNOWLEDGE message as response.
This counter counts the number of CIRCUIT GROUP

Confidential and Proprietary Information of ZTE CORPORATION 133


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

UNBLOCKING ACKNOWLEDGE messages in A-interface BSSMAP


messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of uplink CIRCUIT
GROUP UNBLOCKING ACKNOWLEDGE messages transmitted at
A-interface.
Measurement When BSC sends the CIRCUIT GROUP UNBLOCKING
Point ACKNOWLEDGE message to MSC, the counter increments. The
measurement point is A2, as shown in Figure 103.
Unit Times

C901360072
Definition Number of DL CIRCUIT GROUP UNBLOCKING ACKNOWLEDGE
messages
Description When BSC decides to unblock some terrestrial circuit of A-
interface, it sends a CIRCUIT GROUP UNBLOCK message to MSC.
After MSC performs appropriate handlings, it returns a CIRCUIT
GROUP UNBLOCKING ACKNOWLEDGE message as response.
This counter counts the number of CIRCUIT GROUP
UNBLOCKING ACKNOWLEDGE messages in A-interface BSSMAP
messages received by BSC.
Usage The counter is used to find out the frequency of downlink
CIRCUIT GROUP UNBLOCKING ACKNOWLEDGE messages
transmitted at A-interface.
Measurement When BSC receives the CIRCUIT GROUP UNBLOCKING
Point ACKNOWLEDGE message, the counter increments. The
measurement point is A2, as shown in Figure 102.
Unit Times

C901360073
Definition Number of UL UNEQUIPPED CIRCUIT messages
Description During circuit maintenance process, if BSC can not find the
circuit in the message, it returns the UNEQUIPPED CIRCUIT
message to MSC. This counter counts the number of
UNEQUIPPED CIRCUIT messages in A-interface BSSMAP
messages sent to MSC from BSC.
Usage The counter is used to find out the frequency of uplink
UNEQUIPPED CIRCUIT messages transmitted at A-interface.
Measurement When BSC sends the UNEQUIPPED CIRCUIT message to MSC,
Point the counter increments. The measurement point is A, as shown
in Figure 104.

134 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - BSSMAP Message Measurement

FIGURE 104 – MEASUREMENT POINT OF BSC SENDING UNEQUIPPED


CIRCUIT MESSAGE TO MSC

Unit Times

C901360074
Definition Number of DL UNEQUIPPED CIRCUIT messages
Description During circuit maintenance process, if MSC can not find the
circuit in the message, it returns the UNEQUIPPED CIRCUIT
message to BSC. This counter counts the number of
UNEQUIPPED CIRCUIT messages in A-interface BSSMAP
messages received by BSC.
Usage The counter is used to find out the frequency of downlink
UNEQUIPPED CIRCUIT messages transmitted at A-interface.
Measurement When BSC receives the UNEQUIPPED CIRCUIT message, the
Point counter increments. The measurement point is A, as shown in
Figure 105.

FIGURE 105 – MEASUREMENT POINT OF MSC SENDING UNEQUIPPED


CIRCUIT MESSAGE TO BSC

BSC MSC

UNEQUIPPED CIRCUIT

Unit Times

C901360075
Definition Number of CHANGE CIRCUIT messages
Description When A-interface terrestrial circuits are allocated only by BSC, if
MSC wants to perform circuit handover for a call connection,
MSC will send a CHANGE CIRCUIT message to BSC and release
the circuit at the same time. This counter counts the number of
CHANGE CIRCUIT messages in A-interface BSSMAP messages
received by BSC.
Usage The counter is used to find out the frequency of CHANGE
CIRCUIT messages transmitted at A-interface.

Confidential and Proprietary Information of ZTE CORPORATION 135


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Measurement When BSC receives the CHANGE CIRCUIT message, the counter
Point increments. The measurement point is A1, as shown in Figure
106.

FIGURE 106 – PROCESS OF MSC SENDING CH ANGE CIRCUIT MESSAGE TO


BSC

Unit Times

C901360076
Definition Number of CHANGE CIRCUIT ACK messages
Description When A-interface terrestrial circuits are allocated only by BSC, if
MSC wants to perform circuit handover for a call connection,
MSC will send a CHANGE CIRCUIT message to BSC and release
the circuit at the same time. After BSC receives the message, it
selects a new circuit being occupied that satisfies requirement,
sends the circuit information in the CHANGE CIRCUIT ACK
message to MSC, and releases the circuit.
This counter counts the number of CHANGE CIRCUIT ACK
messages in A-interface BSSMAP messages received by BSC.
Usage The counter is used to find out the frequency of CHANGE
CIRCUIT ACK messages transmitted at A-interface.
Measurement When BSC sends the CHANGE CIRCUIT ACK message to MSC,
Point the counter increments. The measurement point is A2, as shown
in Figure 106.
Unit Times

C901360077
Definition Number of HANDOVER PERFORMED ACK messages
Description This counter counts the number of HANDOVER PERFORMED ACK
messages received by BSC from MSC.
Usage The counter is used to find out cases of BSC receiving the
HANDOVER PERFORMED ACK message from MSC.
Measurement When BSC receives the HANDOVER PERFORMED ACK message
Point from MSC, the counter increments.
Unit Times

136 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8

A-Interface Message
Measurement

The A-interface message measurement performs statistics for


the number of A-interface messages generated and received by
BSC. This chapter introduces the meaning, usage, and
measurement point of A-interface message measurement
counters.

Overview
The A-interface message measurement performs statistics for
uplink/downlink DTAP message, BSSMAP message, and received
incorrect BSSMAP message. Statistic unit in this measurement is
CMP.

A-Interface Message Measurement


Counter Index
Table 12 lists counters related to A-interface Message
measurement.

TABLE 12 – A-INTERFACE MESSAGE MEASUREMENT COUNTERS

Counter ID What It Counts


C901370001 Number of UL DTAP messages
C901370002 Number of DL DTAP messages
C901370003 Number of UL BSSMAP messages
C901370004 Number of DL BSSMAP messages
Number of DL BSSMAP messages received with
C901370005
error

Confidential and Proprietary Information of ZTE CORPORATION 137


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Counter ID What It Counts


Number of chosen for MSC Load share by
C901370006
NULL_NRI
Number of chosen for MSC Load share by the NRI
C901370007
not in the MSC pool

C901370001
Definition Number of UL DTAP messages
Description This counter counts the number of A-interface DTAP messages
sent to MSC from BSC.
Usage The counter analyzes the frequency of uplink DTAP messages
transmitted at A-interface.
Measurement The counter counts when BSC sends the DTAP message to MSC.
Point The measurement point is A, as shown in Figure 107.

FIGURE 107 – MEASUREM ENT POINT OF BSC SENDING A-INTERFACE DT AP


MESSAGE TO MSC

BSC MSC

DTAP

Unit Times

C901370002
Definition Number of DL DTAP messages
Description This counter counts the number of DTAP messages received by
BSC from MSC. MSC can carry the DTAP message in the
Connection Indication message, Connection Confirm message,
Disconnection Indication message, and Data Indication message.
Usage The counter analyzes the frequency of downlink DTAP messages
transmitted at A-interface.
Measurement The counter counts when BSC receives the Connection Indication
Point message, Connection Confirm message, Disconnection Indication
message, or Data Indication message, these messages
containing DTAP message. The measurement point is A, as
shown in Figure 108.

138 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - A-Interface Message Measurement

FIGURE 108 – MEASUREM ENT POINT OF MSC SENDING A-INTERFACE DT AP


MESSAGE TO BSC

Unit Times

C901370003
Definition Number of UL BSSMAP messages
Description This counter counts the number of messages containing BSSMAP
message sent to MSC from BSC. BSC can carry the uplink
BSSMAP message in the Connection Request message, Data
Request message, or UnitData Request message.
Usage The counter analyzes the frequency of uplink BSSMAP messages
transmitted at A-interface.
Measurement The counter counts when BSC sends the Connection Request
Point message, Data Request message, or UnitData Request message
to MSC, these messages containing BSSMAP message. The
measurement point is A, as shown in Figure 109.

FIGURE 109 – MEASUREMENT POINT OF BSC SENDING A-INTERFACE


B S S M AP M E S S A G E T O M S C

Unit Times

C901370004
Definition Number of DL BSSMAP messages
Description This counter counts the number of BSSMAP messages received
by BSC from MSC. MSC can carry the BSSMAP message in the
Connection Indication message, Connection Confirm message,
Data Indication message, and UnitData Indication message.
Usage The counter analyzes the frequency of downlink BSSMAP
messages transmitted at A-interface.
Measurement The counter counts when BSC receives the Connection Indication
Point message, Connection Confirm message, Data Indication
message, or UnitData Indication message, these messages

Confidential and Proprietary Information of ZTE CORPORATION 139


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

containing BSSMAP message. The measurement point is A, as


shown inFigure 110.

FIGURE 110 – MEASUREMENT POINT OF BSC RECEIVING A-INTERFACE


B S S M AP M E S S A G E F R O M M S C

BSC MSC

BSSMAP

Unit Times

C901370005
Definition Number of DL BSSMAP messages received with error
Description This counter counts the number of incorrect BSSMAP messages
received by BSC from MSC. Such incorrect BSSMAP messages
include L3 message with zero length, BSSMAP message of which
the length does not match the length of its contained L3
message, decoding error, or messge type error.
Usage The counter analyzes the frequency of received incorrect
BSSMAP messages transmitted at A-interface.
Measurement The counter counts when BSC receives incorrect BSSMAP
Point message.
Unit Times

C901370006
Definition Number of chosen for MSC Load share by NULL_NRI
Description This counter counts the number of a MSC being chosen for load
sharing by NULL_NRI within the measurement period.
Usage This counter is used to find out the frequency that the original
serving MSC in the pool allocates NULL_NRI to MS to make a
MSC actively shares the load.
Measurement The counter counts when iBSC chooses an appropriate MSC
Point route for MS access.
Unit Times

C901370007
Definition Number of chosen for MSC Load share by the NRI not in the
MSC pool

140 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - A-Interface Message Measurement

Description This counter counts the number of a MSC being chosen for load
sharing by non-NULL_NRI within the measurement period.
Usage This counter is used to find out the frequency of a MSC's sharing
load due to MS accessing the network through NRI which is not
of the MSC.
Measurement The counter counts when iBSC chooses an appropriate MSC
Point route for MS access.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 141


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This page is intentionally blank.

142 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9

Terrestrial Resource
Availability Measurement

This chapter introduces the meaning, usage and measurement


point of terrestrial resource availability measurement counters.

Overview
The terrestrial resource availability measurement performs
statistics for the availability of terrestrial resource, including the
average number of available BSC trunk circuits, the average
number of unavailable BSC trunk circuits, the maximum number
of busy BSC trunk circuits, the total busy time of BSC trunk
circuits, and the total congestion time of BSC trunk circuits. All
these information reflects the trunk circuit resource usage.
Statistic unit in this measurement is BSC.

Terrestrial Resource Availability


Measurement Counter Index
Table 13 lists counters related to terrestrial resource availability
measurement.

TABLE 13 – TERRESTRIAL RESOURCE AV AILABILITY MEASUREMENT


COUNTERS

Counter ID What It Counts


C901380001 Mean number of available trunk circuits
C901380002 Mean number of unavailable trunk circuits
C901380003 Maximum number of busy trunk circuits
C901380004 Busy time of trunk circuit

Confidential and Proprietary Information of ZTE CORPORATION 143


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Counter ID What It Counts


C901380005 Congestion time of trunk circuit
C901380006 Mean number of available UDP port
C901380007 Mean number of unavailable UDP port
C901380008 Number of allocation AIPB board success
C901380009 Number of allocation AIPB board failure
C901380010 Maximum number of seizure UDP port
C901380011 Number of successful one time request UDP port to
AIPB
C901380012 Number of successful two time request UDP port to
AIPB
C901380013 Number of successful three time request UDP port
to AIPB
C901380014 Number of failure request UDP port to AIPB
C901380015 Seizure duration of UDP port

C901380001
Definition Mean number of available trunk circuits
Descripti This counter counts the average number of trunk circuits that
on can be used normally.
Usage The counter reflects the current trunk circuit usage.
Measurement The counter counts when system periodically queries database
Point for circuit information.
Unit Times

C901380002
Definition Mean number of unavailable trunk circuits
Description This counter counts the average number of trunk circuits that
can not be used normally, including the number of circuits being
occupied and the number of circuits being blocked.
Usage The counter reflects the current trunk circuit usage.
Measurement The counter counts when system periodically queries database
Point for circuit information.
Unit Times

144 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - Terrestrial Resource Availability Measurement

C901380003
Definition Maximum number of busy trunk circuits
Description This counter counts the maximum number of trunk circuits being
occupied during the measurement period.
Usage The counter reflects the transient occupation condition of trunk
circuits.
Measurement There are three measurement points for the maximum number
Point of busy trunk circuits.
„ After the trunk circuit is occupied successfully, if the
maximum number of busy trunk circuits exceeds the
recorded value, then the counter's value is updated.
„ Before the trunk circuit is released, if the maximum number
of busy trunk circuits exceeds the recorded value, then the
counter's value is updated.
„ During periodical measurement, if the maximum number of
busy trunk circuits exceeds the recorded value, then the
counter's value is updated.
Unit Times

C901380004
Definition Busy time of trunk circuit
Description This counter counts the total time of all trunk circuits being
occupied during the measurement period.
Usage The counter reflects the busy condition of trunk circuits.
Measurement There are three measurement points for the busy time of trunk
Point circuits.
„ Before the trunk circuit is occupied successfully, the counter
calculates the occupation time and accumulates.
„ Before the trunk circuit is released, the counter calculates
the occupation time and accumulates.
„ During periodical measurement, the counter calculates the
occupation time and accumulates.
Unit Second

C901380005
Definition Congestion time of trunk circuit
Description This counter counts the total time of failing to request trunk
circuit

Confidential and Proprietary Information of ZTE CORPORATION 145


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Usage The counter reflects the congestion condition of trunk circuits.


Measurement There are three measurement points for the congestion time of
Point trunk circuits.
„ Before the trunk circuit is attempted to be occupied, if the
congestion identifier is set, then the counter calculates the
congestion time and accumulates.
„ Before the trunk circuit is released, if the congestion
identifier is set, then the counter calculates the congestion
time and accumulates.
„ During periodical measurement, if the congestion identifier is
set, then the counter calculates the congestion time and
accumulates.
Unit Second

C901380006
Definition Mean number of available UDP port
Description This counter counts the average number of available UDP ports.
Usage The counter is used to find out the average number of available
UDP ports.
Measurement The counter counts when system periodically queries database
Point for circuit information.
Unit Times

C901380007
Definition Mean number of unavailable UDP port
Description This counter counts the average number of unavailable UDP
ports.
Usage The counter is used to find out the average number of
unavailable UDP ports.
Measurement The counter counts when system periodically queries database
Point for circuit information.
Unit Times

C901380008
Definition Number of allocation AIPB board success
Description This counter counts the number of allocating AIPB board
successfully. The RANCS module receives the
EV_RANUMC_RADIO_APPLY message and requests AIPB

146 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - Terrestrial Resource Availability Measurement

resource from database. If the request succeeds, the counter


accumulates.
Usage The counter is used to find out the frequency of allocating AIPB
board successfully.
Measurement When the request of AIPB board from database is returned
Point successfully, the counter accumulates. The measurement point
is A, as shown in Figure 111.

FIGURE 111 – REQUESTING RESOURCE FROM DAT AB ASE SUCCESSFULLY

Unit Times

C901380009
Definition Number of allocation AIPB board failure
Description This counter counts the number of AIPB board allocation failure.
The RANCS module receives the EV_RANUMC_RADIO_APPLY
messge and requests AIPB resource from database. If the
request fails, the counter accumulates.
Usage The counter is used to find out the frequency of AIPB board
allocation failure.
Measurement When the request of AIPB board from database fails, the counter
Point accumulates. The measurement point is A, as shown in Figure
112.

FIGURE 112 – REQUESTING RESOURCE FROM DAT AB ASE FAILURE

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 147


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901380010
Definition Maximum number of seizure UDP port
Description This counter counts the maximum number of UDP ports being
occupied.
Usage The counter is used to find out the maximum number of UDP
ports being occupied.
Measurement The counter counts at the following time points.
Point
„ After the UDP port is occupied successfully, if the maximum
number of busy UDP ports exceeds the recorded value, then
the counter's value is updated.
„ Before the UDP port is released, if the maximum number of
busy UDP ports exceeds the recorded value, then the
counter's value is updated.
„ During periodical measurement, if the maximum number of
busy UDP ports exceeds the recorded value, then the
counter's value is updated.
Unit Times

C901380011
Definition Number of successful one time request UDP port to AIPB
Description This counter counts the number of successfully requesting AIPB
board for UDP port through only one request.
The RANCS module receives the EV_RANUMC_RADIO_APPLY
message, and after requesting database for AIPB resource
successfully, it sends the connection request to the connection
module.
When BSC receives the correct EV_RANCONN_IPA_CONN_ACK
message from the connection module, if the number of times of
requesting UDP port is only one, then the counter accumulates.
Usage The counter is used to find out the frequency of successfully
requesting AIPB board for UDP port through only one request.
Measurement When the connection succeeds and the requesting AIPB board
Point for UDP port succeeds through only one request, the counter
accumulates. The measurement point is A, as shown in Figure
111.
Unit Times

C901380012
Definition Number of successful two time request UDP port to AIPB

148 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - Terrestrial Resource Availability Measurement

Description This counter counts the number of successfully requesting AIPB


board for UDP port through two requests.
The RANCS module receives the EV_RANUMC_RADIO_APPLY
message, and after requesting database for AIPB resource
successfully, it sends the connection request to the connection
module.
When BSC receives the correct EV_RANCONN_IPA_CONN_ACK
message from the connection module, if the number of times of
requesting UDP port is two, then the counter accumulates.
Usage The counter is used to find out the frequency of successfully
requesting AIPB board for UDP port through two requests.
Measurement When the connection succeeds and the requesting AIPB board
point for UDP port succeeds after two requests, the counter
accumulates. The measurement point is A, as shown in Figure
111.
Unit Times

C901380013
Definition Number of successful three time request UDP port to AIPB
Description This counter counts the number of successfully requesting AIPB
board for UDP port through three requests.
The RANCS module receives the EV_RANUMC_RADIO_APPLY
message, and after requesting database for AIPB resource
successfully, it sends the connection request to the connection
module.
When BSC receives the correct EV_RANCONN_IPA_CONN_ACK
message from the connection module, if the number of times of
requesting UDP port is three, then the counter accumulates.
Usage The counter is used to find out the frequency of successfully
requesting AIPB board for UDP port through three requests.
Measurement When the connection succeeds and the requesting AIPB board
point for UDP port succeeds after three requests, the counter
accumulates. The measurement point is A, as shown in Figure
111.
Unit Times

C901380014
Definition Number of failure request UDP port to AIPB
Description This counter counts the number of failing to request AIPB board
for UDP port.

Confidential and Proprietary Information of ZTE CORPORATION 149


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

The RANCS module receives the EV_RANUMC_RADIO_APPLY


message, and after requesting database for AIPB resource
successfully, it sends the connection request to the connection
module.
When BSC receives the correct EV_RANCONN_IPA_CONN_NACK
message from the connection module, if the failure is due to
requesting UDP port failure, the counter accumulates.
Usage The counter is used to find out the frequency of failing to
request AIPB board for UDP port.
Measurement When the connection failure message is returned, the counter
point accumulates. The measurement point is A, as shown in Figure
112.
Unit Times

C901380015
Definition Seizure duration of UDP port
Description This counter counts the total time of UDPPort being occupied.
Usage The counter is used to find out the total time of UDPPort being
occupied.
Measurement The counter counts at the following time points.
point
„ Before UDPPort is occupied successfully, the counter
calculates the occupation time and accumulates.
„ Before UDPPort is released, the counter calculates the
occupation time and accumulates.
„ During periodical measurement, the counter calculates the
occupation time and accumulates.
Unit Second

150 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10

Ater Message
Measurement

Ater message measurement measures the conditions of Ater


interface messages. This chapter introduces the meaning, usage,
and measurement point of different counters for Ater message
statistic.

Overview
Ater interface message counters are used to collect statistics on
messages transceived on Ater interface. It is counted by
AterDispatch according to iTC office.

Ater Message Measurement Counter


Index
Table 14 lists the counters related to Ater message statistic.

TABLE 14 ATER MESSAGE MEASUREMENT COUNTERS

Counter ID What It Counts


Number of UL BLOCK Ater single CIRCUIT
C901390001
messages
Number of DL BLOCKING Ater single CIRCUIT
C901390002
ACKNOWLEDGE messages
Number of UL UNBLOCK Ater single CIRCUIT
C901390003
messages
Number of DL UNBLOCKING Ater single CIRCUIT
C901390004
ACKNOWLEDGE messages
Number of DL BLOCK Ater single CIRCUIT
C901390005
messages

Confidential and Proprietary Information of ZTE CORPORATION 151


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Counter ID What It Counts


Number of UL BLOCKING Ater single CIRCUIT
C901390006
ACKNOWLEDGE messages
Number of DL UNBLOCK Ater single CIRCUIT
C901390007
messages
Number of UL UNBLOCKING Ater single CIRCUIT
C901390008
ACKNOWLEDGE messages
C901390009 Number of UL RESET Ater CIRCUIT messages
C901390010 Number of DL RESET Ater CIRCUIT messages
Number of UL RESET Ater CIRCUIT ACKNOWLEDGE
C901390011
messages
Number of DL RESET Ater CIRCUIT ACKNOWLEDGE
C901390012
messages
Number of UL BLOCK Ater GROUP CIRCUIT
C901390013
messages
Number of DL BLOCK Ater GROUP CIRCUIT
C901390014
messages
Number of UL BLOCKING Ater GROUP CIRCUIT
C901390015
ACKNOWLEDGE messages
Number of DL BLOCKING Ater GROUP CIRCUIT
C901390016
ACKNOWLEDGE messages
C901390017 Number of UL UNBLOCK CIRCUIT GROUP messages
Number of DL UNBLOCK Ater GROUP CIRCUIT
C901390018
messages
Number of UL UNBLOCKING Ater GROUP CIRCUIT
C901390019
ACKNOWLEDGE messages
Number of DL UNBLOCKING Ater GROUP CIRCUIT
C901390020
ACKNOWLEDGE messages
Number of UL UNEQUIPPED Ater CIRCUIT
C901390021
messages
Number of DL UNEQUIPPED Ater CIRCUIT
C901390022
messages
C901390023 Number of UL BLOCK A CIRCUIT messages
Number of DL BLOCKING A CIRCUIT
C901390024
ACKNOWLEDGE messages
C901390025 Number of UL UNBLOCK A CIRCUIT messages
Number of DL UNBLOCKING A CIRCUIT
C901390026
ACKNOWLEDGE messages
C901390027 Number of DL BLOCK A CIRCUIT messages
Number of UL BLOCKING A CIRCUIT
C901390028
ACKNOWLEDGE messages
C901390029 Number of DL UNBLOCK A CIRCUIT messages
Number of UL UNBLOCKING A CIRCUIT
C901390030
ACKNOWLEDGE messages

152 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Ater Message Measurement

Counter ID What It Counts


C901390031 Number of UL BLOCK A CIRCUIT GROUP messages
C901390032 Number of DL BLOCK A CIRCUIT GROUP messages
Number of UL BLOCKING A CIRCUIT GROUP
C901390033
ACKNOWLEDGE messages
Number of DL BLOCKING A CIRCUIT GROUP
C901390034
ACKNOWLEDGE messages
Number of UL UNBLOCK A CIRCUIT GROUP
C901390035
messages
Number of DL UNBLOCK A CIRCUIT GROUP
C901390036
messages
Number of UL UNBLOCKING A CIRCUIT GROUP
C901390037
ACKNOWLEDGE messages
Number of DL UNBLOCKING A CIRCUIT GROUP
C901390038
ACKNOWLEDGE messages
C901390039 Number of UL UNEQUIPPED A CIRCUIT messages
C901390040 Number of DL UNEQUIPPED A CIRCUIT messages
C901390041 Number of UL Ater RESET messages
C901390042 Number of DL Ater RESET messages
Number of UL Ater RESET ACKNOWLEDGE
C901390043
messages
Number of DL Ater RESET ACKNOWLEDGE
C901390044
messages
C901390045 Number of UL Ater CONFUSION messages
C901390046 Number of DL Ater CONFUSION messages
C901390047 Number of RESOURCE REQUEST messages
C901390048 Number of RESOURCE INDICATION messages
C901390049 Number of RESOURCE NON-INDICATION messages
C901390050 Number of resource release request messages
C901390051 Number of resource release acknowledge messages
C901390052 Number of resource failure messages
C901390053 Number of TFO status messages
C901390054 Number of TFO common voice type messages
C901390055 Number of TFO control messages

C901390001
Definition Number of UL BLOCK Ater single CIRCUIT messages
 Description This counter counts the number of “BLOCK” messages sent by
BSC to iTC.

Confidential and Proprietary Information of ZTE CORPORATION 153


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

 Measurement When BSC sends a “BLOCK” message, this counter increments.


point

Unit Times

C901390002
Definition Number of DL BLOCKING Ater single CIRCUIT ACKNOWLEDGE
messages
 Description This counter counts the number of “BLOCKING ACKNOWLEDGE”
messages received by BSC from iTC.
 Measurement When BSC receives a “BLOCKING ACKNOWLEDGE” message,
point this counter increments.
Unit Times

C901390003
Definition Number of UL UNBLOCK Ater single CIRCUIT messages
 Description This counter counts the number of “UNBLOCK” messages sent by
BSC to iTC.
 Measurement When BSC sends an “UNBLOCK” message, this counter
point increments.
Unit Times

C901390004
Definition Number of DL UNBLOCKING Ater single CIRCUIT ACKNOWLEDGE
messages
 Description This counter counts the number of “UNBLOCKING ACKNOWLEDGE”
messages received by BSC from iTC.
 Measurement When BSC receives an “UNBLOCKING ACKNOWLEDGE” message,
point this counter increments.
Unit Times

C901390005
Definition Number of DL BLOCK Ater single CIRCUIT messages
 Description This counter counts the number of “BLOCK” messages received by
BSC from iTC.

154 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Ater Message Measurement

Measurement When BSC receives a “BLOCK” message, this counter increments.


point

Unit Times

C901390006
Definition Number of UL BLOCKING Ater single CIRCUIT ACKNOWLEDGE
messages
Description This counter counts the number of “BLOCKING
ACKNOWLEDGE” messages sent by BSC to iTC.
 Measurement
When BSC sends a “BLOCKING ACKNOWLEDGE” message, this
point
counter increments.
Unit Times

C901390007
Definition Number of DL UNBLOCK Ater single CIRCUIT messages
 Description This counter counts the number of “UNBLOCK” messages received by
BSC from iTC.
 Measurement When BSC receives an “UNBLOCK” message, this counter
point increments.
Unit Times

C901390008
Definition Number of UL UNBLOCKING Ater single CIRCUIT ACKNOWLEDGE
messages
 Description This counter counts the number of “UNBLOCKING ACKNOWLEDGE”
messages sent by BSC to iTC.
 Measurement When BSC sends an “UNBLOCKING ACKNOWLEDGE” message,
point this counter increments.
Unit Times

C901390009
Definition Number of UL RESET Ater CIRCUIT messages
 Description This counter counts the number of “RESET CIRCUIT” messages sent
by BSC to iTC.

Confidential and Proprietary Information of ZTE CORPORATION 155


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

 Measurement When BSC sends a “RESET CIRCUIT” message, this counter


point increments.
Unit Times

C901390010
Definition Number of DL RESET Ater CIRCUIT messages
 Description This counter counts the number of “RESET CIRCUIT” messages
received by BSC from iTC.
 Measurement When BSC receives a “RESET CIRCUIT” message, this counter
point increments.
Unit Times

C901390011
Definition Number of UL RESET Ater CIRCUIT ACKNOWLEDGE messages
 Description This counter counts the number of “RESET CIRCUIT ACKNOWLEDGE”
messages sent by BSC to iTC.
 Measurement When BSC sends a “RESET CIRCUIT ACKNOWLEDGE” message,
point this counter increments.
Unit Times

C901390012
Definition Number of DL RESET Ater CIRCUIT ACKNOWLEDGE messages
 Description This counter counts the number of “RESET CIRCUIT ACKNOWLEDGE”
messages received by BSC from iTC.
 Measurement When BSC receives a “RESET CIRCUIT ACKNOWLEDGE”
point message, this counter increments.
Unit Times

C901390013
Definition Number of UL BLOCK Ater GROUP CIRCUIT messages
 Description This counter counts the number of “BLOCK CIRCUIT GROUP”
messages sent by BSC to iTC.
 Measurement When BSC sends a “BLOCK CIRCUIT GROUP” message, this
point counter increments.
Unit Times

156 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Ater Message Measurement

C901390014
Definition Number of DL BLOCK Ater GROUP CIRCUIT messages
 Description This counter counts the number of “BLOCK CIRCUIT GROUP”
messages received by BSC from iTC.
 Measurement When BSC receives a “BLOCK CIRCUIT GROUP” message, this
point counter increments.
Unit Times

C901390015
Definition Number of UL BLOCKING Ater GROUP CIRCUIT ACKNOWLEDGE
messages
 Description This counter counts the number of “BLOCKING CIRCUIT GROUP
ACKNOWLEDGE” messages sent by BSC to iTC.
 Measurement When BSC sends a “BLOCKING CIRCUIT GROUP
point ACKNOWLEDGE” message, this counter increments.
Unit Times

C901390016
Definition Number of DL BLOCKING Ater GROUP CIRCUIT ACKNOWLEDGE
messages
 Description This counter counts the number of “BLOCKING CIRCUIT GROUP
ACKNOWLEDGE” messages received by BSC from iTC.
 Measurement When BSC receives a “BLOCKING CIRCUIT GROUP
point ACKNOWLEDGE” message, this counter increments.
Unit Times

C901390017
Definition Number of UL UNBLOCK Ater GROUP CIRCUIT messages
 Description This counter counts the number of “UNBLOCK CIRCUIT GROUP”
messages sent by BSC to iTC.
 Measurement When BSC sends an “UNBLOCK CIRCUIT GROUP” message, this
point counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 157


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901390018
Definition Number of DL UNBLOCK Ater GROUP CIRCUIT messages
 Description This counter counts the number of “UNBLOCK CIRCUIT GROUP”
messages received by BSC from iTC.
 Measurement When BSC receives an “UNBLOCK CIRCUIT GROUP” message,
point this counter increments.
Unit Times

C901390019
Definition Number of UL UNBLOCKING Ater GROUP CIRCUIT
ACKNOWLEDGE messages
 Description This counter counts the number of “UNBLOCKING CIRCUIT GROUP
ACKNOWLEDGE” messages sent by BSC to iTC.
 Measurement When BSC sends an “UNBLOCKING CIRCUIT GROUP
point ACKNOWLEDGE” message, this counter increments.
Unit Times

C901390020
Definition Number of DL UNBLOCKING Ater GROUP CIRCUIT
ACKNOWLEDGE messages
 Description This counter counts the number of “UNBLOCKING CIRCUIT GROUP
ACKNOWLEDGE” messages received by BSC from iTC.
 Measurement When BSC receives an “UNBLOCKING CIRCUIT GROUP
point ACKNOWLEDGE” message, this counter increments.
Unit Times

C901390021
Definition Number of UL UNEQUIPPED Ater CIRCUIT messages
 Description This counter counts the number of “UNEQUIPPED CIRCUIT” messages
sent by BSC to iTC.
 Measurement When BSC sends an “UNEQUIPPED CIRCUIT” message, this
point counter increments.
Unit Times

158 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Ater Message Measurement

C901390022
Definition Number of DL UNEQUIPPED Ater CIRCUIT messages
 Description This counter counts the number of “UNEQUIPPED CIRCUIT” messages
received by BSC from iTC.
 Measurement When BSC receives an “UNEQUIPPED CIRCUIT” message, this
point counter increments.
Unit Times

C901390023
Definition Number of UL BLOCK A CIRCUIT messages
 Description This counter counts the number of “BLOCK A CIRCUIT” messages
sent by BSC to iTC.
 Measurement When BSC sends a “BLOCK A CIRCUIT” message, this counter
point increments.
Unit Times

C901390024
Definition Number of DL BLOCKING A CIRCUIT ACKNOWLEDGE messages
 Description This counter counts the number of “BLOCKING A CIRCUIT
ACKNOWLEDGE” messages received by BSC from iTC.
 Measurement When BSC receives a BLOCKING A CIRCUIT ACKNOWLEDGE”
point message, this counter increments.
Unit Times

C901390025
Definition Number of UL UNBLOCK A CIRCUIT messages
 Description This counter counts the number of “UNBLOCK A CIRCUIT” messages
sent by BSC to iTC.
 Measurement When BSC sends an “UNBLOCK A CIRCUIT” message, this
point counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 159


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901390026
Definition Number of DL UNBLOCKING A CIRCUIT ACKNOWLEDGE
messages
 Description This counter counts the number of “UNBLOCKING A CIRCUIT
ACKNOWLEDGE” messages received by BSC from iTC.
 Measurement When BSC receives an “UNBLOCKING A CIRCUIT
point ACKNOWLEDGE” message, this counter increments.
Unit Times

C901390027
Definition Number of DL BLOCK A CIRCUIT messages
 Description This counter counts the number of “BLOCK A CIRCUIT” messages
received by BSC from iTC.
 Measurement When BSC receives a “BLOCK A CIRCUIT” message, this counter
point increments.
Unit Times

C901390028
Definition Number of UL BLOCKING A CIRCUIT ACKNOWLEDGE messages
 Description This counter counts the number of “BLOCKING A CIRCUIT
ACKNOWLEDGE” messages sent by BSC to iTC.
 Measurement When BSC sends a “BLOCKING A CIRCUIT ACKNOWLEDGE”
point message, this counter increments.
Unit Times

C901390029
Definition Number of DL UNBLOCK A CIRCUIT messages
 Description This counter counts the number of “UNBLOCK A CIRCUIT” messages
received by BSC from iTC.
 Measurement When BSC receives an “UNBLOCK A CIRCUIT” message, this
point counter increments.
Unit Times

160 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Ater Message Measurement

C901390030
Definition Number of UL UNBLOCKING A CIRCUIT ACKNOWLEDGE
messages
 Description This counter counts the number of “UNBLOCKING A CIRCUIT
ACKNOWLEDGE” messages sent by BSC to iTC.
 Measurement When BSC sends an “UNBLOCKING A CIRCUIT ACKNOWLEDGE”
point message, this counter increments.
Unit Times

C901390031
Definition Number of UL BLOCK A CIRCUIT GROUP messages
 Description This counter counts the number of “BLOCK A CIRCUIT GROUP”
messages sent by BSC to iTC.
 Measurement When BSC sends a “BLOCK A CIRCUIT GROUP” message, this
point counter increments.
Unit Times

C901390032
Definition Number of DL BLOCK A CIRCUIT GROUP messages
 Description This counter counts the number of “BLOCK A CIRCUIT GROUP”
messages received by BSC from iTC.
 Measurement When BSC receives a “BLOCK A CIRCUIT GROUP” message, this
point counter increments.
Unit Times

C901390033
Definition Number of UL BLOCKING A CIRCUIT GROUP ACKNOWLEDGE
messages
 Description This counter counts the number of “BLOCKING A CIRCUIT
GROUP ACKNOWLEDGE” messages sent by BSC to iTC.
 Measurement When BSC sends a “BLOCKING A CIRCUIT GROUP
point ACKNOWLEDGE” message, this counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 161


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901390034
Definition Number of DL BLOCKING A CIRCUIT GROUP ACKNOWLEDGE
messages
 Description This counter counts the number of “BLOCKING A CIRCUIT
GROUP ACKNOWLEDGE” messages received by BSC from iTC.
 Measurement When BSC receives a “BLOCKING A CIRCUIT GROUP
point ACKNOWLEDGE” message, this counter increments.
Unit Times

C901390035
Definition Number of UL UNBLOCK A CIRCUIT GROUP messages
 Description This counter counts the number of “UNBLOCK A CIRCUIT
GROUP” messages sent by BSC to iTC.
 Measurement When BSC sends an “UNBLOCK A CIRCUIT GROUP” message,
point this counter increments.
Unit Times

C901390036
Definition Number of DL UNBLOCK A CIRCUIT GROUP messages
 Description This counter counts the number of “UNBLOCK A CIRCUIT
GROUP” messages received by BSC from iTC.
 Measurement When BSC receives an “UNBLOCK A CIRCUIT GROUP” message,
point this counter increments.
Unit Times

C901390037
Definition Number of UL UNBLOCKING A CIRCUIT GROUP ACKNOWLEDGE
messages 
Description This counter counts the number of “UNBLOCKING A CIRCUIT
GROUP ACKNOWLEDGE” messages sent by BSC to iTC.
 Measurement When BSC sends an “UNBLOCKING A CIRCUIT GROUP
point ACKNOWLEDGE” message, this counter increments.
Unit Times

162 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Ater Message Measurement

C901390038
Definition Number of DL UNBLOCKING A CIRCUIT GROUP ACKNOWLEDGE
messages
 Description This counter counts the number of “UNBLOCKING A CIRCUIT
GROUP ACKNOWLEDGE” messages received by BSC from iTC.
 Measurement When BSC receives an “UNBLOCKING A CIRCUIT GROUP
point ACKNOWLEDGE” message, this counter increments.
Unit Times

C901390039
Definition Number of UL UNEQUIPPED A CIRCUIT messages
 Description This counter counts the number of “UNEQUIPPED A CIRCUIT”
messages sent by BSC to iTC.
 Measurement When BSC sends an “UNEQUIPPED A CIRCUIT” message, this
point counter increments.

Unit Times

C901390040
Definition Number of DL UNEQUIPPED A CIRCUIT messages
 Description This counter counts the number of “UNEQUIPPED A CIRCUIT”
messages received by BSC from iTC.
 Measurement When BSC receives an “UNEQUIPPED A CIRCUIT” message, this
point counter increments.
Unit Times

C901390041
Definition Number of UL Ater RESET messages
 Description This counter counts the number of “RESET” messages sent by
BSC to iTC.
 Measurement When BSC sends a “RESET” message, this counter increments.
point

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 163


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901390042
Definition Number of DL Ater RESET messages
 Description This counter counts the number of “RESET” messages received
by BSC from iTC.
 Measurement When BSC receives a “RESET” message, this counter increments.
point

Unit Times

C901390043
Definition Number of UL Ater RESET ACKNOWLEDGE messages
 Description This counter counts the number of “RESET ACKNOWLEDGE”
messages sent by BSC to iTC.
 Measurement When BSC sends a “RESET ACKNOWLEDGE” message, this
point counter increments.

Unit Times

C901390044
Definition Number of DL Ater RESET ACKNOWLEDGE messages
 Description This counter counts the number of “RESET ACKNOWLEDGE”
messages received by BSC from iTC.
 Measurement When BSC receives a “RESET ACKNOWLEDGE” message, this
point counter increments.

Unit Times

C901390045
Definition Number of UL Ater CONFUSION messages
 Description This counter counts the number of “CONFUSION” messages sent
by BSC to iTC.
 Measurement When BSC sends a “CONFUSION” message, this counter
point increments.

Unit Times

164 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Ater Message Measurement

C901390046
Definition Number of DL Ater CONFUSION messages
 Description This counter counts the number of “CONFUSION” messages
received by BSC from iTC.
 Measurement When BSC receives a “CONFUSION” message, this counter
point increments.

Unit Times

C901390047
Definition Number of RESOURCE REQUEST messages
 Description This counter counts the number of “RESOURCE REQUEST”
messages sent by BSC to iTC.
 Measurement When BSC sends a “RESOURCE REQUEST” message, this counter
point increments.

Unit Times

C901390048
Definition Number of RESOURCE INDICATION messages
 Description This counter counts the number of “RESOURCE REQUEST
ACKNOWLEDGE” messages received by BSC from iTC.
 Measurement When BSC receives a “RESOURCE REQUEST ACKNOWLEDGE”
point message, this counter increments.
Unit Times

C901390049
Definition Number of RESOURCE NON-INDICATION messages
 Description This counter counts the number of “RESOURCE REQUEST
NEGTIVE ACKNOWLEDGE” messages received by BSC from iTC.
 Measurement When BSC receives a “RESOURCE REQUEST NEGTIVE
point ACKNOWLEDGE” message, this counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 165


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901390050
Definition Number of resource release request messages
 Description This counter counts the number of “RESOURCE RELEASE
REQUEST” messages sent by BSC to iTC.
 Measurement When BSC sends a “RESOURCE RELEASE REQUEST” message,
point this counter increments.
Unit Times

C901390051
Definition Number of resource release acknowledge messages
 Description This counter counts the number of “RESOURCE RELEASE
ACKNOWLEDGE” messages received by BSC from iTC.
 Measurement When BSC receives a “RESOURCE RELEASE ACKNOWLEDGE”
point message, this counter increments.
Unit Times

C901390052
Definition Number of resource failure messages
 Description This counter counts the number of “RESOURCE FAILURE”
messages received by BSC from iTC.
 Measurement When BSC receives a “RESOURCE FAILURE” message, this
point counter increments.

Unit Times

C901390053
Definition Number of TFO status messages
 Description This counter counts the number of “TFO STATE” messages
received by BSC from iTC.
 Measurement When BSC receives a “TFO STATE” message, this counter
point increments.

Unit Times

166 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Ater Message Measurement

C901390054
Definition Number of TFO common voice type messages
 Description This counter counts the number of “TFO CONMMONTYPE”
messages received by BSC from iTC.
 Measurement When BSC receives a “TFO CONMMONTYPE” message, this
point counter increments.
Unit Times

C901390055
Definition Number of TFO control messages
 Description This counter counts the number of “TFO CONTROL
INFORMATION” messages sent by BSC to iTC.
 Measurement When BSC sends a “TFO CONTROL INFORMATION” message,
point this counter increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 167


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This page is intentionally blank.

168 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11

MTP2 Signal Link


Measurement

MTP2 signal link measurement collects statistics on events such


as code error, frame loss, fault, and congestions on lay 2. The
purpose is to reflect the working status of lay 2 links. This
chapter introduces the meaning, usage, and measurement point
of MTP2 statistic counters.

Overview
Platform signaling defines a MTP2 performance statistic structure:
T_PM_SIG_MTP2_Link and defines a structure array according to
the maximum number of links, ie, 128. In this way, error codes,
frame loss, faults, and congestion can be counted according to
link number.

MTP2 Signal Link Measurement


Counter Index
Table 15 lists the counters related to MTP2 signal link
measurement.

TABLE 15 MTP2 SIGNAL LINK MEASUREMENT COUNTERS

Counter ID What It Counts


C901400001 Number of error SU due to Abnormal Flag
C901400002 Number of error SU Length Error
C901400003 Number of Out of Alignment
C901400004 Number of error SU due not to Octet
C901400005 Number of error SU due to CRC Error

Confidential and Proprietary Information of ZTE CORPORATION 169


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Counter ID What It Counts


C901400006 Number of Other error
C901400007 Number of Negative Acknowledgement Received
C901400008 Octets of MSU Retransmitted
C901400009 Number of MSU Resend
C901400010 Number of Align Error
C901400011 Number of Error SU
C901400012 Number of MSU discarded due to congestion
C901400013 Number of SL failure due to Abnormal FIBR/BSNR
C901400014 Number of SL failure due to Excessive delay of ack
C901400015 Number of SL failure due to Excessive error rate
Number of SL failure due to Excessive duration of
C901400016
congestion

C901400001
Definition Number of error SU due to Abnormal Flag
Description This counter counts the number of SUs with seven consecutive
1s in message code stream received by an MTP2 link. According
to the protocol, the valid flag is 01111110 and a flag with
seven consecutive 1s is invalid. If this message carries 1111111,
this counter increments.
Usage This counter is used to find out the occurrence of SUs carrying
seven consecutive 1s in message code stream received by an
MTP2 link.
Measurement When an MTP2 link receives a message code stream carrying
point 1111111, this counter increments.
Unit Times

C901400002
Definition Number of error SU Length Error
Description This counter counts the number of SUs with overlong or too
short messages received by an MTP2 link. According to the
protocol, a signal unit (SU) contains at least six octets and at
most 279 octets. If the number of octets is smaller than 6 or
bigger than 279, the length of the signal unit is wrong. and this
counter increments.(Note: an octet is equal to a byte, that is 8
bits.)
Usage This counter is used to find out the occurrence of SUs carrying
overlong or too short messages received by an MTP2 link.

170 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - MTP2 Signal Link Measurement

Measurement When a message octet is shorter than 6 or longer than 127, this
point counter increments.
Unit Times

C901400003
Definition Number of Out of Alignment
Description This counter counts the number of message code streams out of
alignment received by an MTP2 link. According to the protocol,
there is an eight-bit flag each at the head and tail of a signal
unit to identify the signal unit. When the flag is invalid or the
length of the signal unit exceeds the maximum value, location is
lost. In this case, this counter increments.
Usage This counter is used to find out the occurrence of message code
streams out of alignment received by an MTP2 link.
Measurement When the flag is invalid or the length of the signal unit exceeds
point the maximum value, this counter increments.
Unit Times

C901400004
Definition Number of error SU due not to Octet
Description This counter counts the times of message code streams with
non-octet received by an MTP2 link. According to the protocol,
the composition of the signal unit is a multiple of 8 bits. When
an octet composed of non-8 bits occurs, this counter increments.
Usage This counter is used to find out the occurrence of message code
streams with non-octet received by an MTP2 link.
Measurement When an octet composed of non-8 bits occurs, this counter
point increments.
Unit Times

C901400005
Definition Number of error SU due to CRC Error
Description This counter counts the number of CRC errors received by an MTP2 link.
According to the protocol, a signal unit has a 16-bit check code at
its tail, which is generated when the signal unit is sent. The
check code is checked at the receiving end. When a CRC error
occurs, this counter increments.
Usage This counter is used to find out the occurrence of CRC errors
received by an MTP2 link.

Confidential and Proprietary Information of ZTE CORPORATION 171


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Measurement When a CRC error occurs, this counter increments.


point

Unit Times

C901400006
Definition Number of Other error
Description This counter counts the number of other message errors
received by an MTP2 link. When errors other than the above four
types occur, this counter increments.
Usage This counter is used to find out the occurrence of message errors
other than the above four types received by an MTP2 link.
Measurement When errors other than the above four types occur, this counter
point increments.
Unit Times

C901400007
Definition Number of Negative Acknowledgement Received
Description This counter counts the number of negative acknowledgements
received by an MTP2 link.
Usage This counter is used to find out the occurrence of negative
acknowledgements received by an MTP2 link.
Measurement When an MTP2 link receives a negative acknowledgement, this
point counter increments.
Unit Times

C901400008
Definition Octets of MSU Retransmitted
Description This counter counts the number of octets retransmitted by an
MTP2 link.
Usage This counter is used to find out the frequency of retransmission
of an MTP2 link.
Measurement When an MTP2 link is retransmitted, this counter increments by
point the corresponding octet.
Unit octet

172 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - MTP2 Signal Link Measurement

C901400009
Definition Number of MSU Resend
Description This counter counts the number of MSU packets resent by MTP2.
Usage This counter is used to find out the frequency of MTP2 resending.
Measurement When an MTP2 link is resent, this counter increments by the
point corresponding number of resent packets.
Unit Packet

C901400010
Definition Number of Align Error
Description This counter counts the number of alignment or check error of
an MTP2 link.
Usage This counter is used to find out the frequency of alignment
failures of an MTP2 link.
Measurement When an MTP2 link receives AlignNtpsbl during alignment, this
point counter increments.
Unit Times

C901400011
Definition Number of Error SU
Description This counter counts the number of error SUs received by an
MTP2 link.
Usage This counter is used to find out the frequency of receiving error
SUs received by an MTP2 link.
Measurement When an MTP2 link receives an error SU, this counter increments.
point

Unit Times

C901400012
Definition Number of MSU discarded due to congestion
Description This counter counts the number of MSUs discarded due to
congestion resulted from full buffer on an MTP2 link.
Usage This counter is used to find out the frequency discarding MSUs
due to congestion resulted from full buffer on an MTP2 link.

Confidential and Proprietary Information of ZTE CORPORATION 173


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Measurement When an MTP2 link discards MSU due to congestion, this counter
point increments.
Unit Times

C901400013
Definition Number of SL failure due to Abnormal FIBR/BSNR
Description This counter counts the number of SL failures due to abnormal
FIBR/BSNR.
Usage This counter is used to find out the occurrence of SL failures due
to abnormal FIBR/BSNR.
Measurement When an MTP2 link is broken due to abnormal FIBBSN, this
point counter increments.
Unit Times

C901400014
Definition Number of SL failure due to Excessive delay of ack
Description This counter counts the number of SL failures due to excessive
delay of acknowledgement.
Usage This counter is used to find out the occurrence of SL failures due
to excessive delay of acknowledgement.
Measurement When an MTP2 link is broken due to excessive delay of
point acknowledgement, this counter increments.
Unit Times

C901400015
Definition Number of SL failure due to Excessive error rate
Description This counter counts the number of SL failures due to excessive
error rate.
Usage This counter is used to find out the occurrence of SL failures due
to excessive error rate.
Measurement When an MTP2 link is broken due to excessive error rate, this
point counter increments.
Unit Times

174 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - MTP2 Signal Link Measurement

C901400016
Definition Number of SL failure due to Excessive duration of congestion
Description This counter counts the number of SL failures due to excessive
duration of congestion.
Usage This counter is used to find out the occurrence of SL failures due
to excessive duration of congestion.
Measurement When an MTP2 link is broken due to congestion, this counter
point increments.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 175


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This page is intentionally blank.

176 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 12

CPU/MEM Measurement

CPU/MEM measurement provides CPU seizure ratio and memory


usage in the specified period for the background. This helps
users to know the running status of the system.

Overview
To explicate CPU and memory usages during platform running
procedure and provide reference for future upgrade and
maintenance, the system enables users to view peak CPU usage,
remaining memory, and peak of the rest UB in the specified
period. Eight counters are provided, as shown in the following
sections.

CPU/MEM Measurement Counter


Index
Table 16 lists the counters related to CPU/MEM measurement.

TABLE 16 CPU/MEM MEASUREMENT COUNTERS

Counter ID What It Counts


C901410001 Peak memory usage of the main processor
C901410002 Mean value of the memory usage
C901410003 Peak load of CPU usage of the main processor
C901410004 Mean ratio of the CPU usage
Duration of the main processor keeping in peak
C901410005
state
C901410006 The time when peak load CPU usage occurred
C901410007 peak kilo-bytes of the rest UB
C901410008 Mean kilo-bytes of the rest UB

Confidential and Proprietary Information of ZTE CORPORATION 177


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901410001
Definition Peak memory usage of the main processor
Description This counter compares the memory usages of all measurement
points measured at an interval of 2 seconds in the measurement
period and specifies the maximum measurement point as the
peak load.
Usage This counter is used to view the peak memory usage of the main
processor in measurement period.
Measurement In the sampling period, sample a memory usage every 2
point seconds.
Unit Percent

C901410002
Definition Mean value of the memory usage
Description This counter averages the memory usages of all measurement
points at an interval of 2 seconds in the measurement period
and outputs the mean value.
Usage This counter is used to find out the mean memory usage of the
system.
Measurement In the sampling period, sample a memory usage every 2
point seconds.
Unit Percent

C901410003
Definition Peak load of CPU usage of the main processor
 Description This counter samples CPU usage at an interval of 2 seconds and
specifies the maximum memory usage in the measurement
period as the peak load of CPU usage of the main processor.
Usage This counter is used to view the peak load of CPU usage in the
specified measurement period.
Measurement In the sampling period, sample a CPU usage every 2 seconds
point and use the peak value as the maximum value of the
measurement point.
Unit Percent

178 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 12 - CPU/MEM Measurement

C901410004
Definition Mean ratio of the CPU usage
 Description This counter samples CPU usage at an interval of 2 seconds,
averages the CPU usages of all measurement points, and
outputs the mean value.
Usage This counter is used to find out the mean CPU usage in the
specified period.
Measurement In the sampling period, sample a CPU usage every 2 seconds.
point Divide the sum of the values of all measurement points by the
number of measurement points.
Unit Percent

C901410005
Definition Duration of the main processor keeping in peak state
 Description This counter counts the duration of the main processor in peak
state.
Usage This counter is used to find out the duration of CPU peak status,
which can serve as a reference for knowing system operating
conditions.
Measurement In the sampling period, count and record the maximum values of
point main processor peak at all measurement points, and accumulate
the duration of the maximum measurement point.
Unit Second

C901410006
Definition The time when peak load CPU usage occurred
 Description This counter records the time when peak load of main processor
occurred for the first time in the measurement period. The time
is the number of seconds relative to 00:00:00 January 1, 2000.
Usage This counter is used to find out the time when CPU peak
occurred, which provides a basis for system performance
analysis.
Measurement In the sampling period, trace the time when the load of main
point processor reaches peak. At the end of collection period, output
the traced time point.
Unit Second

Confidential and Proprietary Information of ZTE CORPORATION 179


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901410007
Definition peak kilo-bytes of the rest UB
 Description In the measurement period, sample bytes of the rest UB at an
interval of 2 seconds, collect statistics in the sampling period,
and output the peak value of measurement point.
Usage This counter is used to find out the peak kilo-bytes of the rest
UB.
Measurement In the sampling period, do sampling at an interval of 2 seconds
point and get the maximum kilo-bytes of the rest UB.
Unit Byte

C901410008
Definition Mean kilo-bytes of the rest UB
 Description In the sampling period, do sampling at an interval of 2 seconds.
Divide the sum of the values of all measurement points by the
number of measurement points.
Usage This counter is used to find out the condition of the rest UB.
Measurement At the end of a collection period, average the bytes of the rest
point UB sampled every 2 seconds.
Unit Byte

180 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13

SCTP AS Measurement

SCTP AS measurement measures SCTP-related statistic values,


including packets received and sent, congestion control, and
delay and dithering of network transmission. This chapter
introduces the meaning, usage, and measurement point of SCTP
statistic counters.

Overview
SCTP AS measurement mainly collects statistics on values
related to SCTP, such as data receiving and sending and
associated items (congestion, delay, and dithering).

SCTP AS Measurement Counter


Index
Table 17 lists the counters related to SCTP AS measurement.

TABLE 17 SCTP AS MEASUREMENT COUNTERS

Counter ID What It Counts


Number of IP packets dropped by SCTP due to
C901420001
some reasons
C901420002 Number packets received from ip
C901420003 Bytes of packets received from ip
C901420004 Number of packets sent to ip
C901420005 Bytes of packets sent to ip
C901420006 Number of messages sent to ulp
C901420007 Bytes of messages sent to ulp
C901420008 Number of messages received from ulp
C901420009 Bytes of messages received from

Confidential and Proprietary Information of ZTE CORPORATION 181


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Counter ID What It Counts


C901420010 Number of Congestion
C901420011 Duration of congestion
C901420012 Chunk number of fast retransmission
C901420013 Chunk number of time-out retransmission
C901420014 RTT is lower than T1
C901420015 RTT is between T1 and T2
C901420016 RTT is higher than T2
C901420017 Number of network transmission dropped packets
C901420018 Maximum delay of network transmission
C901420019 Minimum delay of network transmission
C901420020 Total delay of network transmission(high 4 bytes)
C901420021 Total delay of network transmission(low 4 bytes)
C901420022 Number of delay samples of network transmission
C901420023 Maximum dithering of network transmission
C901420024 Minimum dithering of network transmission
Total dithering of network transmission(high 4
C901420025
bytes)
Total dithering of network transmission(low 4
C901420026
bytes)
Number of dithering samples of network
C901420027
transmission
Number of IP packets dropped by SCTP due to
C901420001
some reasons
C901420002 Number packets received from ip
C901420003 Bytes of packets received from ip
C901420004 Number of packets sent to ip
C901420005 Bytes of packets sent to ip
C901420006 Number of messages sent to ulp
C901420007 Bytes of messages sent to ulp
C901420008 Number of messages received from ulp
C901420009 Bytes of messages received from
C901420010 Number of Congestion
C901420011 Duration of congestion
C901420012 Chunk number of fast retransmission
C901420013 Chunk number of time-out retransmission
C901420014 RTT is lower than T1
C901420015 RTT is between T1 and T2
C901420016 RTT is higher than T2

182 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13 - SCTP AS Measurement

Counter ID What It Counts


C901420017 Number of network transmission dropped packets
C901420018 Maximum delay of network transmission
C901420019 Minimum delay of network transmission
C901420020 Total delay of network transmission(high 4 bytes)
C901420021 Total delay of network transmission(low 4 bytes)
C901420022 Number of delay samples of network transmission
C901420023 Maximum dithering of network transmission
C901420024 Minimum dithering of network transmission
Total dithering of network transmission(high 4
C901420025
bytes)
Total dithering of network transmission(low 4
C901420026
bytes)
Number of dithering samples of network
C901420027
transmission

C901420001
Definition Number of IP packets dropped by SCTP due to some reasons
Description This counter counts the number of IP packets dropped by the
SCTP, including heartbeat and SHUTDOWN. When SCTP drops
packets, this counter increments.
Usage This counter is used to find out the number of packets dropped
by SCTP.
Measurement When SCTP drops packets, this counter will count.
point

Unit Times

C901420002
Definition Number packets received from ip
Description This counter counts the number of IP packets received by the
SCTP, including heartbeat and SHUTDOWN. When SCTP receives
packets, this counter increments.
Usage This counter is used to find out the number of packets received
by SCTP.
Measurement When SCTP receives packets, this counter will count.
point

Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 183


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901420003
Definition Bytes of packets received from ip
Description This counter counts the number of packet bytes received by the
SCTP. The length of only valid data in DATA CHUNK is counted.
When SCTP receives DATA packets, this counter accumulates.
Usage This counter is used to find out the number of DATA packet
bytes received by SCTP.
Measurement When SCTP receives DATA packets, this counter will count.
point

Unit Times

C901420004
Definition Number of packets sent to ip
Description This counter counts the number of IP packets sent by the SCTP,
including heartbeat and SHUTDOWN. When SCTP sends packets,
this counter increments.
Usage This counter is used to find out the number of packets sent by
SCTP.
Measurement When SCTP sends packets, this counter will count.
point

Unit Times

C901420005
Definition Bytes of packets sent to ip
Description This counter counts the number of packet bytes sent by the
SCTP. The length of only valid data in DATA CHUNK is counted.
When SCTP sends DATA packets, this counter accumulates.
Usage This counter is used to find out the number of DATA packet
bytes sent by SCTP.
Measurement When SCTP sends DATA packets, this counter will count.
point

Unit Times

C901420006
Definition Number of messages sent to ulp

184 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13 - SCTP AS Measurement

Description This counter counts the number of messages sent by the SCTP
to ULP. When SCTP sends messages to ULP, this counter
increments.
Usage This counter is used to find out the number of messages sent by
SCTP to ULP.
Measurement When SCTP sends messages to ULP, this counter will count.
point

Unit Times

C901420007
Definition Bytes of messages sent to ulp
Description This counter counts the number of message bytes sent by the
SCTP to ULP. When SCTP sends messages to ULP, this counter
accumulates.
Usage This counter is used to find out the number of message bytes
sent by SCTP to ULP.
Measurement When SCTP sends messages to ULP, this counter will count.
point

Unit Times

C901420008
Definition Number of messages received from ulp
 Description This counter counts the number of message bytes received by
the SCTP from ULP. When SCTP receives messages from ULP,
this counter accumulates.
Usage This counter is used to find out the number of messages
received by SCTP from ULP.
Measurement When SCTP receives ULP messages, this counter will count.
point

Unit Times

C901420009
Definition Bytes of messages received from ulp
Description This counter counts the number of message bytes received by
the SCTP from ULP. When SCTP receives messages from ULP,
this counter accumulates.
Usage

Confidential and Proprietary Information of ZTE CORPORATION 185


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This counter is used to find out the number of message bytes


received by SCTP from ULP.
Measurement When SCTP receives ULP messages, this counter will count.
point

Unit Times

C901420010
Definition Number of Congestion
Description This counter counts the number of congestion control module
zooming out congestion windows. When congestion control
module zooms out congestion windows, this counter
accumulates.
Usage This counter is used to find out the number of SCTP congestions.
Measurement When congestion control module zooms out congestion windows,
point this counter will count.
Unit Times

C901420011
Definition Duration of congestion
 Description This counter counts the congestion duration.
Usage This counter is used to find out the duration of SCTP congestion.
Measurement SCTP congestion control
point

Unit ms

C901420012
Definition Chunk number of fast retransmission
Description This counter counts the number of chunks fast transmitted by
the SCTP. If the data sending end receives three SACKs
indicating loss of a DATA chunk, SCTP fast transmits chunks and
this counter increments.
Usage This counter is used to find out the number of chunks fast
transmitted by SCTP.
Measurement When SCTP fast transmits chunks, this counter will count.
point

Unit Times

186 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13 - SCTP AS Measurement

C901420013
Definition Chunk number of time-out retransmission
Description This counter counts the number of chunks retransmitted by the
SCTP due to timeout. If the timeout retransmission timer times
out, SCTP fast retransmits chunks and this counter increments.
Usage This counter is used to find out the number of chunks fast
transmitted by SCTP.
Measurement When SCTP retransmits chunks due to timeout, this counter will
point count.
Unit Times

C901420014
Definition RTT is lower than T1
Description This counter counts the statistics of RTT lower than T1. When
RTT is lower than T1, this counter accumulates.
Usage This counter is used to find out the statistics of RTT lower than
T1.
Measurement When the sampled RTT is lower than T1, this counter will counts.
point

Unit None

C901420015
Definition RTT is between T1 and T2
Description This counter counts the statistics of RTT between T1 and T2.
When RTT is between T1 and T2, this counter accumulates.
Usage This counter is used to find out the statistics of RTT between T1
and T2.
Measurement When the sampled RTT is between T1 and T2, this counter will
point count.
Unit None

C901420016
Definition RTT is higher than T2
Description This counter counts the statistics of RTT higher than T2. When
RTT is higher than T2, this counter accumulates.

Confidential and Proprietary Information of ZTE CORPORATION 187


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Usage This counter is used to find out the statistics of RTT higher than
T2.
Measurement When the sampled RTT is higher than T2, this counter will count.
point

Unit None

C901420017
Definition Number of network transmission dropped packets
Description This counter counts the number of dropped packets during
network transmission and chunks re-transmitted. When SCTP
receives no response after sending packets, this counter counts
during retransmission.
Usage This counter is used to find out the statistics of packets dropped
during network transmission.
Measurement If SCTP receives no response after sending packets, this counter
point will count during retransmission.
Unit Times

C901420018
Definition Maximum delay of network transmission
Description This counter counts the maximum delay of network transmission
of SCTP packets in an interval. When the actual network
transmission delay is greater than maximum delay of network
transmission, the actual one prevails.
Usage This counter is used to find out the maximum delay of network
transmission.
Measurement When RTT is calculated based on RTO sampling, determine the
point maximum delay of network transmission.
Unit ms

C901420019
Definition Minimum delay of network transmission
Description This counter counts the minimum delay of network transmission
of SCTP packets in an interval. When the actual network
transmission delay is smaller than maximum delay of network
transmission, it replaces the minimum delay of network
transmission.
Usage

188 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13 - SCTP AS Measurement

This counter is used to find out the minimum delay of network


transmission.
Measurement When RTT is calculated based on RTO sampling, determine the
point minimum delay of network transmission.
Unit ms

C901420020
Definition Total delay of network transmission (high 4 bytes)
Description This counter counts the high 4 bytes of total delay of network
transmission for processing SCTP packets.
Usage This counter is used to find out the total delay of network
transmission for processing SCTP packets.
Measurement When RTT is calculated based on RTO sampling, delay of
point network transmission is accumulated.
Unit ms

C901420021
Definition Total delay of network transmission(low 4 bytes)
Description This counter counts the low 4 bytes of total delay of network
transmission for processing SCTP packets.
Usage This counter is used to find out the total delay of network
transmission for processing SCTP packets.
Measurement When RTT is calculated based on RTO sampling, delay of
point network transmission is accumulated.
Unit ms

C901420022
Definition Number of delay samples of network transmission
 Description This counter counts the number of delay samples of network
transmission. In measurement internal, each time delay is
sampled, this counter accumulates.
Usage This counter is used to find out the number of delay samples in
measurement interval.
Measurement When a delay sampling is done in measurement interval, this
point counter will count.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 189


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901420023
Definition Maximum dithering of network transmission
Description This counter counts the maximum dithering of network
transmission of SCTP packets in an interval. When the actual
network transmission dithering is greater than maximum
dithering of network transmission, the actual one prevails.
Usage This counter is used to find out the maximum dithering of
network transmission.
Measurement When RTT is calculated based on RTO sampling, determine the
point maximum dithering of network transmission.
Unit ms

C901420024
Definition Minimum dithering of network transmission
Description This counter counts the minimum dithering of network
transmission of SCTP packets in an interval. When the actual
network transmission dithering is smaller than maximum
dithering of network transmission, it replaces the minimum
dithering of network transmission.
Usage This counter is used to find out the minimum dithering of
network transmission.
Measurement When RTT is calculated based on RTO sampling, determine the
point minimum dithering of network transmission.
Unit ms

C901420025
Definition Total dithering of network transmission(high 4 bytes)
Description This counter counts the high 4 bytes of total dithering of
network transmission for processing SCTP packets.
Usage This counter is used to find out the total dithering of network
transmission for processing SCTP packets.
 Measurement When RTT is calculated based on RTO sampling, dithering of
point network transmission is accumulated.
Unit ms

190 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13 - SCTP AS Measurement

C901420026
Definition Total dithering of network transmission(low 4 bytes)
 Description This counter counts the low 4 bytes of total dithering of network
transmission for processing SCTP packets.
 Usage This counter is used to find out the total dithering of network
transmission for processing SCTP packets.
 Measurement When RTT is calculated based on RTO sampling, dithering of
point network transmission is accumulated.
Unit ms

C901420027
Definition Number of dithering samples of network transmission
Description This counter counts the number of delay samples of network
transmission. In measurement internal, each time dithering is
sampled, this counter accumulates.
Usage This counter is used to find out the number of dithering samples
in measurement interval.
Measurement When a dithering sampling is done in measurement interval, this
point counter will count.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 191


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This page is intentionally blank.

192 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 14

IP Port Performance
Statistics

This chapter introduces the meaning, usage, and measurement


point of IP port performance statistic counters.

Overview
IP port performance statistics performs measurement for the
number of messages received, transmitted, and discarded at the
external physical port of IP interface board.
IP port performance statistics involves debugging performance
data and performance data that are useful for module debugging
and commissioning. Periodical statistics of IP port performance
data can reflect the characteristic of the port's history flow, such
as the average number of messages transmitted/received per
second at the port, flow burst, and bidirectional flow symmetry,
etc. At present, physical boards it supports include BIPI and GIPI.
Statistic unit in this measurement is times that the message is
counted. The measurement obtains the average number of
received/transmitted messages per second (PPS) at the port by
controlling the period of sampling IP port performance data.

IP Port Performance Statistics


Counter Index
Table 18 lists the counters related to IP port performance
statistics.

Confidential and Proprietary Information of ZTE CORPORATION 193


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

TABLE 18 – IP PORT PERFOMRANCE STATISTICS COUNTERS

Counter ID What It Counts


C901430001 Packets number received
C901430002 Packets number transmitted
C901430003 Packets number discarded at rx end
C901430004 Packets number discarded at tx end

C901430001
Definition Packets number received
Description This counter counts the number of messages received at IP port.
The counter increments when a message is received.
Usage This counter is used to observe the number of messages
received at IP port.
Measurement The counter accumulates when there is message received at IP
point port.
Unit Times

C901430002
Definition Packets number transmitted
Description This counter counts the number of messages sent at IP port. The
counter increments when a message is sent.
Usage This counter is used to observe the number of messages sent at
IP port.
Measurement The counter accumulates when there is message sent at IP port.
point

Unit Times

C901430003
Definition Packets number discarded at rx end
Description This counter counts the number of messages discarded at the
receiving end of IP port. The counter increments when an
incorrect message is discarded at the receiving end.
Usage This counter is used to observe the number of messages
discarded at the receiving end of IP port.

194 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 14 - IP Port Performance Statistics

Measurement The counter accumulates when there is incorrect message


point discarded at the receiving end of IP port.
Unit Times

C901430004
Definition Packets number discarded at tx end
Description This counter counts the number of messages discarded at the
transmitting end of IP port. The counter increments when an
incorrect message is discarded at the transmitting end.
Usage This counter is used to observe the number of messages
discarded at the transmitting end of IP port.
Measurement The counter accumulates when there is incorrect message
point discarded at the transmitting end of IP port.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 195


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This page is intentionally blank.

196 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 15

GTRUNK Resource
Statistics

This chapter introduces the meaning, usage, and measurement


point of GTRUNK resource statistic counters.

Overview
GTRUNK refers to the timeslot resource on UPU DSP. GTRUNK
resource statistics is used to monitor the GTRUNK resource
usage, which helps implement Gb interface capacity expansion.
Statistic unit in this measurement is UPU DSP.

GTRUNK Resource Statistics


Counter Index
Table 19 lists the counters related to GTRUNK resource statistics.

TABLE 19 – GTRUNK RESOURCE STATISTICS COUNTERS

Counter ID What It Counts


C901440001 Maximum of used DSP TS
C901440002 Max of the used sampling according to DSP TS
C901440003 Amount of used DSP TS
C901440004 Number of regular scanning and sampling

Confidential and Proprietary Information of ZTE CORPORATION 197


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901440001
Definition Maximum of used DSP TS
Description This counter counts the maximum number of each UPU DSP
timeslot resource being occupied within the measurement period.
Usage This counter is used to find out the occupation of UPU DSP
timeslot resource by PS service, which helps optimize the UPU
DSP resource.
Measurement The counter counts when PS user requests for the UPU DSP
point timeslot resource successfully.
Unit Times

C901440002
Definition Max of the used sampling according to DSP TS
Description This counter counts the number of available UPU DSP timeslot
resource at the measurement point of C901440001, which is the
sum of the number of occupied timeslots and the number of idle
timeslots.
Usage This counter is used to find out the availability of UPU DSP
timeslot resource when PS service occupies the UPU DSP
timeslot resource the most.
Measurement The counter counts when PS user requests for the UPU DSP
point timeslot resource successfully.
Unit Times

C901440003
Definition Amount of used DSP TS
Description This counter accumulates at each measurement point to get the
sum of UPU DSP timeslot resource used by PS service within the
measurement period.
Usage This counter reflects the average occupation of UPU DSP
resource in PS service.
Measurement The counter counts when PS user requests for the UPU DSP
point timeslot resource successfully.
Unit Times

198 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 15 - GTRUNK Resource Statistics

C901440004
Definition Number of regular scanning and sampling
Description The counter increments at the measurement point of
C901440003. This counter and C901440003 reflect the average
occupation of UPU DSP resource in PS service.
Usage This counter reflects the average occupation of UPU DSP
resource in PS service.
Measurement The counter counts when PS user requests for the UPU DSP
point timeslot resource successfully.
Unit Times

Confidential and Proprietary Information of ZTE CORPORATION 199


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This page is intentionally blank.

200 Confidential and Proprietary Information of ZTE CORPORATION


Appendix A

Abbreviations

Abbreviation Full Name


A
Abis Abis Interface
AIPP A-Interface Peripheral Processor
AIU A-Interface Unit
AUC Access Unit Controller
B
BCCH Broadcast Channel
BSC Base Station Controller
BTS Base Transceiver Station
BSSAP Base Station Subsystem Application Part
BSSGP Base Station Subsystem GPRS Protocol
BSSMAP Base Station Subsystem Management
Application Part
BTS Base Transceiver Station
BVC BSSGP Virtual Connection
BVCI BSSGP Virtual Connection Identifier
C
CBCH Cell Broadcast Channel
CC Call Control
CCCH Common Control Channel
CCH Control Channel
CS Circuit Switched
D
DRT Dual Rate Transcoder
DTAP Direct Transfer Application Part
E

Confidential and Proprietary Information of ZTE CORPORATION 201


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Abbreviation Full Name


EDRT Enhanced Dual Rate Transcoder
EGSM Extended GSM
F
FACCH Fast Associated Control Channel
FACCH/F Fast Associated Control Channel/Full rate
FACCH/H Fast Associated Control Channel/Half rate
FR Frame Relay
FRP Frame Relay Protocol
FU Frame Unit
G
GGSN Gateway GPRS Support Node
GIU GPRS Interface Unit
GPRS General Packet Radio Service
GSM Global System for Mobile communication
GSN GPRS Support Node
H
HSN Hopping Sequence Number
K
KPI Key Performance Indicator
L
LAPD Link Access Protocol of D-Channel
LLC Logical Link Control
LMT Local Management Terminal
LOC Location update
M
MM Mobility Management
MOC Mobile Originated Call
MS Mobile Station
MSC Mobile Switching Center
MO-SM MS Originated Short Message
MT-SM MS Terminated Short Message
MTC Mobile Terminated Call
MTP Message Transfer Part
N
NC Network Controller
NMS Network Management Signaling

202 Confidential and Proprietary Information of ZTE CORPORATION


Appendix A - Abbreviations

Abbreviation Full Name


NMS Network Management Software
NS Network Service
NSE Network Service Entity
NSEI Network Service Entity Identifier
NSVC Network Service Virtual Circuit
O
OMC Operation Maintenance Center
OMCR Operation Maintenance Center Radio
P
PACCH Packet Associated Control Channel
PAGCH Paging and Access Grant Channel
PBGT Power Budget
PCH Paging Channel
PCU Packet Control Unit
PDU Protocol Data Unit
PDCH Packet Data Channel
PDTCH Packet Data Traffic Channel
PDU Protocol Data Unit
PS Packet Switched
R
RMM Radio Management Module
RQ Receiving Quality
RR Radio Resource
S
SACCH Slow Associated Control Channel
SACCH/F Slow Associated Control Channel/Full rate
SACCH/H Slow Associated Control Channel/Half rate
SAPI Service Access Point Identifier
SCCP Signal Correction Control Part
SDCCH Slow Distributed Control Channel
SGSN Serving GPRS Support Node
SIF Service Information Field
SIO Service Information Octets
SM Short Message
SMM Service Management Module
SMS Short Messages Service

Confidential and Proprietary Information of ZTE CORPORATION 203


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Abbreviation Full Name


SS Supplementary Services
T
TA Time Advance
TCH Traffic Channel
TCH/F Traffic Channel/Full rate
TCH/H Traffic Channel/Half rate
TFO Tandem Free Operation
TIC Trunk Interface Circuit
TRX Transceiver
U
UISF User Interface Support Foundation

204 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B

Figures

Figure 1 – Time of PVC unavailable .......................................3


Figure 2 – Time of PVC congestion frame relay .......................4
Figure 3 – Uplink/Downlink NS Data......................................4
Figure 4 – Sending and Receiving PDU Data ...........................5
Figure 5 – PDU data discarded by NS sub layer .......................6
Figure 6 – NSVC Resetting Process........................................6
Figure 7 – NSVC Blocking Process .........................................8
Figure 8 – NSVC Unblocking Process .....................................9
Figure 9 – FR reporting transmission network fault ................ 10
Figure 10 – Blocking NSVC by Background ........................... 11
Figure 11 – FR reporting equipment fault ............................. 11
Figure 12 – NSVC BLOCKED ............................................... 12
Figure 13 – NSVC Unknown ............................................... 12
Figure 14 – NS Protocol Error ............................................. 13
Figure 15 – Test Procedure Being Abnormal ......................... 13
Figure 16 – Blocking Procedure Being Abnormal.................... 14
Figure 17 – Unblocking Procedure Being Abnormal ................ 14
Figure 18 – Uplink/Downlink Data BECN Being Set ................ 16
Figure 19 – Measurement Point of BSS Receiving CS Paging
Message.......................................................................... 20
Figure 20 – Measurement Point of BSS Receiving PS Paging
Message.......................................................................... 20
Figure 21 – SUSPEND Process ............................................ 21
Figure 22 – Measurement Point of BSS Receiving
SUSPEND_NACK Message .................................................. 21
Figure 23 – RESUME Process .............................................. 22

Confidential and Proprietary Information of ZTE CORPORATION 205


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Figure 24 – Measurement Point of BSS Receiving RESUME_NACK


Message.......................................................................... 23
Figure 25 – FLUSH_LL Process............................................ 23
Figure 26 – Measurement Point of BSS Sending LLC_DISCARDED
Message.......................................................................... 24
Figure 27 – BVC_BLOCK Process......................................... 25
Figure 28 – BVC_UNBLOCK Process..................................... 25
Figure 29 – Process of Sending BVC_RESET ......................... 26
Figure 30 – Process of Receiving BVC_RESET ....................... 27
Figure 31 – PERFORM_LOCATION_REQUEST Process ............. 28
Figure 32 – Measurement Point of BSS Receiving
PERFORM_LOCATION_ABORT Message ................................ 29
Figure 33 – POSITION_COMMAND Process ........................... 29
Figure 34 – STATUS Process .............................................. 30
Figure 35 – Power Control Measurement .............................. 40
Figure 36 – Test Procedure Being Abnormal ......................... 60
Figure 37 – Measurement point of the number of receiving RA-
CAPABILITY message ........................................................ 63
Figure 38 – PTP Packet Paging Process ................................ 64
Figure 39 – PTP Circuit Paging Process ................................ 64
Figure 40 – RA-CAPABILITY-UPDATE Process........................ 64
Figure 41 – RADIO-STATUS Process .................................... 65
Figure 42 – FLOW-CONTROL-BVC Process ............................ 67
Figure 43 – FLOW-CONTROL-MS Process ............................. 67
Figure 44 – FLOW-CONTROL-PFC Process ............................ 68
Figure 45 – STATUS Process .............................................. 69
Figure 46 – CREATE-BSS-PFC Process ................................. 72
Figure 47 – MODIFY-BSS-PFC Process ................................. 73
Figure 48 – DELETE-BSS-PFC Process.................................. 74
Figure 49 – Measurement Point of MSC Sending BSSMAP
Message to BSC ............................................................... 95
Figure 50 – Measurement Point of BSC Sending BSSMAP
Message to MSC............................................................... 96
Figure 51 – Measurement Point of BSC Receiving ASSIGNMENT
REQUEST Message from MSC ............................................. 99
Figure 52 – Measurement Point of BSC Sending ASSIGNMENT
COMPLETE Message to MSC ............................................... 99
Figure 53 – Measurement Point of BSC Sending ASSIGNMENT
FAILURE Message to MSC ................................................ 100

206 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B - Figures

Figure 54 – Measurement Point of MSC Sending RESOURCE


REQUEST Message to BSC ............................................... 100
Figure 55 – Measurement Point of BSC Sending RESOURCE
INDICATION Message to MSC........................................... 101
Figure 56 – Measurement Point of MSC Sending PAGING
Message to BSC ............................................................. 101
Figure 57 – Measurement Point of MSC Sending CIPHER MODE
COMMAND Message to BSC.............................................. 102
Figure 58 – Measurement Point of BSC Sending CIPHER MODE
COMPLETE Message to MSC ............................................. 103
Figure 59 – Measurement Point of BSC Sending CIPHER MODE
REJECT Message to MSC.................................................. 103
Figure 60 – Measurement Point of BSC Sending CLASSMARK
UPDATE Message to MSC ................................................. 104
Figure 61 – Measurement Point of MSC Sending CLASSMARK
UPDATE Message to BSC ................................................. 104
Figure 62 – Measurement Point of BSC Sending QUEUING
INDICATION Message to MSC........................................... 105
Figure 63 – Measurement Point of BSC Sending COMPLETE
LAYER 3 INFORMATION Message to MSC............................ 105
Figure 64 – Measurement Point of MSC Sending CLASSMARK
REQUEST Message to BSC ............................................... 106
Figure 65 – Measurement Point of BSC Sending LOAD
INDICATION Message to MSC........................................... 106
Figure 66 – Measurement Point of MSC Sending LOAD
INDICATION Message to BSC ........................................... 107
Figure 67 – Measurement Point of MSC Sending HANDOVER
REQUEST Message to BSC ............................................... 107
Figure 68 – Inter-BSC Handover Process Initiated by BSC .... 108
Figure 69 – Process of MSC Sending HANDOVER CANDIDATE
ENQUIRE Message to BSC................................................ 110
Figure 70 – Measurement Point of BSC Sending HANDOVER
FAILURE Message to MSC ................................................ 111
Figure 71 – Measurement Point of BSC Sending HANDOVER
PERFORMED Message to MSC ........................................... 112
Figure 72 – Measurement Point of MSC Sending HANDOVER
REQUIRED REJECT Message to BSC .................................. 112
Figure 73 – Measurement Point of BSC Sending HANDOVER
DETECT Message to MSC ................................................. 113
Figure 74 – CLEAR Process .............................................. 113
Figure 75 – Measurement Point of BSC Sending CLEAR REQUEST
Message to MSC ............................................................. 114

Confidential and Proprietary Information of ZTE CORPORATION 207


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

Figure 76 – Measurement Point of BSC Sending SAPI "N" REJECT


Message to MSC............................................................. 115
Figure 77 – Measurement Point of BSC Sending CONFUSION
Message to MSC............................................................. 115
Figure 78 – Measurement Point of MSC Sending CONFUSION
Message to BSC ............................................................. 116
Figure 79 – Uplink RESET Process ..................................... 116
Figure 80 – Downlink RESET Process ................................. 117
Figure 81 – Measurement Point of BSC Sending OVERLOAD
Message to MSC............................................................. 118
Figure 82 – Measurement Point of MSC Sending OVERLOAD
Message to BSC ............................................................. 119
Figure 83 – Measurement Point of MSC Sending MSC INVOKE
TRACE Message to BSC ................................................... 119
Figure 84 – Measurement Point of BSC Sending BSS INVOKE
TRACE Message to MSC................................................... 120
Figure 85 – Measurement Point of MSC Sending BSS INVOKE
TRACE Message to BSC ................................................... 120
Figure 86 – Measurement Point of BSC Sending
CONNECTIONLESS INFORMATION Message to MSC ............. 121
Figure 87 – Measurement Point of MSC Sending
CONNECTIONLESS INFORMATION Message to BSC ............. 121
Figure 88 – Measurement Point of BSC Sending SUSPEND
Message to MSC............................................................. 122
Figure 89 – Measurement Point of BSC Sending RESUME
Message to MSC............................................................. 122
Figure 90 – Measurement Point of MSC Sending Common ID
Message to BSC ............................................................. 123
Figure 91 – Measurement Point of MSC Sending LSA
INFORMATION Message to BSC ........................................ 123
Figure 92 – Process of MSC Sending PERFORM LOCATION
REQUEST Message to BSC ............................................... 124
Figure 93 – Measurement Point of MSC Sending PERFORM
LOCATION ABORT Message to BSC ................................... 125
Figure 94 – Process of BSC Sending BLOCK Message to MSC 125
Figure 95 – Process of BSC Sending UNBLOCK Message to MSC
................................................................................... 126
Figure 96 – Process of MSC Sending BLOCK Message to BSC 127
Figure 97 – Process of MSC Sending UNBLOCK Message to BSC
................................................................................... 128
Figure 98 – Process of BSC Sending RESET CIRCUIT Message to
MSC ............................................................................. 129

208 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B - Figures

Figure 99 – Process of MSC Sending RESET CIRCUIT Message to


BSC.............................................................................. 129
Figure 100 – Process of BSC Sending CIRCUIT GROUP BLOCK
Message to MSC ............................................................. 131
Figure 101 – Process of MSC Sending CIRCUIT GROUP BLOCK
Message to BSC ............................................................. 131
Figure 102 – Process of BSC Sending CIRCUIT GROUP UNBLOCK
Message to MSC ............................................................. 133
Figure 103 – Process of MSC Sending CIRCUIT GROUP UNBLOCK
Message to BSC ............................................................. 133
Figure 104 – Measurement Point of BSC Sending UNEQUIPPED
CIRCUIT Message to MSC ................................................ 135
Figure 105 – Measurement Point of MSC Sending UNEQUIPPED
CIRCUIT Message to BSC................................................. 135
Figure 106 – Process of MSC Sending CHANGE CIRCUIT Message
to BSC .......................................................................... 136
Figure 107 – Measurement Point of BSC Sending A-Interface
DTAP Message to MSC..................................................... 138
Figure 108 – Measurement Point of MSC Sending A-Interface
DTAP Message to BSC ..................................................... 139
Figure 109 – Measurement Point of BSC Sending A-Interface
BSSMAP Message to MSC ................................................ 139
Figure 110 – Measurement Point of BSC Receiving A-Interface
BSSMAP Message from MSC............................................. 140
Figure 111 – Requesting Resource from Database Successfully
................................................................................... 147
Figure 112 – Requesting Resource from Database Failure..... 147

Confidential and Proprietary Information of ZTE CORPORATION 209


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This page is intentionally blank.

210 Confidential and Proprietary Information of ZTE CORPORATION


Tables

Table 1 – Manual Summary ..................................................i


Table 2 - Typographical Conventions .................................... iv
Table 3 - Mouse Operation Conventions ................................ iv
Table 4 – Usage Explanation of the Hazardous Substances in
ZXG10 iBSC (V6.20.10)..................................................... vii
Table 5 – NSVC Statistic Measurement Counters .....................1
Table 6 – NSE Statistic Measurement Counters ..................... 17
Table 7 – BTS TRX Measurement Counters ........................... 40
Table 8 – Counters of NSVC Measurement on IPGB HOST....... 57
Table 9 – Counters of Gb Interface Message Measurement on
IPGB HOST ...................................................................... 61
Table 10 – Counters of NSE Measurement on IPGB HOST ....... 75
Table 11 – BSSMAP Message Measurement Counters ............. 96
Table 12 – A-Interface Message Measurement Counters....... 137
Table 13 – Terrestrial Resource Availability Measurement
Counters ....................................................................... 143
Table 14 Ater Message Measurement Counters ................... 151
Table 15 MTP2 signal link measurement Counters .............. 169
Table 16 CPU/MEM Measurement Counters....................... 177
Table 17 SCTP AS Measurement Counters ......................... 181
Table 18 – IP Port Perfomrance Statistics Counters.............. 194
Table 19 – GTRUNK Resource Statistics Counters ................ 197

Confidential and Proprietary Information of ZTE CORPORATION 211


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

This page is intentionally blank.

212 Confidential and Proprietary Information of ZTE CORPORATION


Index

C901300001 ........................3 C901310014 ...................... 25


C901300002 ........................3 C901310015 ...................... 26
C901300003 ........................4 C901310016 ...................... 26
C901300004 ........................4 C901310017 ...................... 26
C901300005 ........................4 C901310018 ...................... 27
C901300006 ........................5 C901310019 ...................... 27
C901300007 ........................5 C901310020 ...................... 27
C901300008 ........................5 C901310021 ...................... 28
C901300009 ........................6 C901310022 ...................... 28
C901300010 ........................6 C901310023 ...................... 29
C901300011 ........................7 C901310024 ...................... 29
C901300012 ........................7 C901310025 ...................... 30
C901300013 ........................7 C901310026 ...................... 30
C901300014 ........................8 C901310027 ...................... 31
C901300015 ........................8 C901310028 ...................... 31
C901300016 ........................8 C901310029 ...................... 31
C901300017 ........................9 C901310030 ...................... 32
C901300018 ........................9 C901310031 ...................... 32
C901300019 ...................... 10 C901310032 ...................... 32
C901300020 ...................... 10 C901310033 ...................... 33
C901300021 ...................... 10 C901310034 ...................... 33
C901300022 ...................... 11 C901310035 ...................... 34
C901300023 ...................... 11 C901310036 ...................... 34
C901300024 ...................... 11 C901310037 ...................... 34
C901300025 ...................... 12 C901310038 ...................... 35
C901300026 ...................... 12 C901310039 ...................... 35
C901300027 ...................... 13 C901310040 ...................... 35
C901300028 ...................... 13 C901310041 ...................... 35
C901300029 ...................... 14 C901310042 ...................... 36
C901300030 ...................... 14 C901310043 ...................... 36
C901300031 ...................... 15 C901310044 ...................... 36
C901300032 ...................... 15 C901310045 ...................... 37
C901300033 ...................... 15 C901310046 ...................... 37
C901300034 ...................... 15 C901310047 ...................... 37
C901300035 ...................... 15 C901310048 ...................... 38
C901300036 ...................... 15 C901310049 ...................... 38
C901300037 ...................... 16 C901310050 ...................... 38
C901310001 ...................... 19 C901320001 ...................... 42
C901310002 ...................... 20 C901320002 ...................... 42
C901310003 ...................... 20 C901320003 ...................... 43
C901310004 ...................... 21 C901320004 ...................... 43
C901310005 ...................... 21 C901320005 ...................... 43
C901310006 ...................... 22 C901320006 ...................... 44
C901310007 ...................... 22 C901320007 ...................... 44
C901310008 ...................... 22 C901320008 ...................... 44
C901310009 ...................... 23 C901320009 ...................... 45
C901310010 ...................... 23 C901320010 ...................... 45
C901310011 ...................... 24 C901320011 ...................... 45
C901310012 ...................... 24 C901320012 ...................... 46
C901310013 ...................... 25 C901320013 ...................... 46

Confidential and Proprietary Information of ZTE CORPORATION 213


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901320014 ...................... 47 C901340023.......................71


C901320015 ...................... 47 C901340024.......................71
C901320016 ...................... 47 C901340025.......................71
C901320017 ...................... 48 C901340026.......................71
C901320018 ...................... 48 C901340027.......................72
C901320019 ...................... 48 C901340028.......................72
C901320020 ...................... 49 C901340029.......................72
C901320021 ...................... 49 C901340030.......................73
C901320022 ...................... 49 C901340031.......................73
C901320023 ...................... 50 C901340032.......................73
C901320024 ...................... 50 C901340033.......................74
C901320025 ...................... 50 C901340034.......................74
C901320026 ...................... 50 C901350001.......................77
C901320027 ...................... 51 C901350002.......................78
C901320028 ...................... 51 C901350003.......................78
C901320029 ...................... 51 C901350004.......................78
C901320030 ...................... 52 C901350005.......................79
C901320031 ...................... 52 C901350006.......................79
C901320032 ...................... 52 C901350007.......................79
C901320033 ...................... 53 C901350008.......................80
C901320034 ...................... 53 C901350009.......................80
C901320035 ...................... 53 C901350010.......................80
C901320036 ...................... 53 C901350011.......................81
C901320037 ...................... 54 C901350012.......................81
C901320038 ...................... 54 C901350013.......................81
C901320039 ...................... 54 C901350014.......................82
C901320040 ...................... 54 C901350015.......................82
C901320041 ...................... 55 C901350016.......................82
C901320042 ...................... 55 C901350017.......................82
C901320043 ...................... 55 C901350018.......................83
C901320044 ...................... 55 C901350019.......................83
C901330001 ...................... 58 C901350020.......................83
C901330002 ...................... 58 C901350021.......................84
C901330003 ...................... 58 C901350022.......................84
C901330004 ...................... 58 C901350023.......................84
C901330005 ...................... 59 C901350024.......................85
C901330006 ...................... 59 C901350025.......................85
C901330007 ...................... 59 C901350026.......................85
C901340001 ...................... 63 C901350027.......................86
C901340002 ...................... 63 C901350028.......................86
C901340003 ...................... 64 C901350029.......................86
C901340004 ...................... 64 C901350030.......................87
C901340005 ...................... 65 C901350031.......................87
C901340006 ...................... 65 C901350032.......................88
C901340007 ...................... 65 C901350033.......................88
C901340008 ...................... 66 C901350034.......................88
C901340009 ...................... 66 C901350035.......................89
C901340010 ...................... 66 C901350036.......................89
C901340011 ...................... 67 C901350037.......................89
C901340012 ...................... 67 C901350038.......................90
C901340013 ...................... 68 C901350039.......................90
C901340014 ...................... 68 C901350040.......................90
C901340015 ...................... 68 C901350041.......................90
C901340016 ...................... 69 C901350042.......................91
C901340017 ...................... 69 C901350043.......................91
C901340018 ...................... 69 C901350044.......................91
C901340019 ...................... 70 C901350045.......................92
C901340020 ...................... 70 C901350046.......................92
C901340021 ...................... 70 C901350047.......................92
C901340022 ...................... 70 C901350048.......................93

214 Confidential and Proprietary Information of ZTE CORPORATION


Index

C901350049 ...................... 93 C901360059 .................... 127


C901350050 ...................... 93 C901360060 .................... 128
C901360001 ...................... 98 C901360061 .................... 128
C901360002 ...................... 99 C901360062 .................... 129
C901360003 .................... 100 C901360063 .................... 129
C901360004 .................... 100 C901360064 .................... 130
C901360005 .................... 101 C901360065 .................... 130
C901360006 .................... 101 C901360066 .................... 131
C901360007 .................... 102 C901360067 .................... 131
C901360008 .................... 102 C901360068 .................... 132
C901360009 .................... 103 C901360069 .................... 132
C901360010 .................... 103 C901360070 .................... 133
C901360011 .................... 104 C901360071 .................... 133
C901360012 .................... 104 C901360072 .................... 134
C901360013 .................... 105 C901360073 .................... 134
C901360014 .................... 105 C901360074 .................... 135
C901360015 .................... 106 C901360075 .................... 135
C901360016 .................... 107 C901360076 .................... 136
C901360017 .................... 107 C901360077 .................... 136
C901360018 .................... 108 C901370001 .................... 138
C901360019 .................... 108 C901370002 .................... 138
C901360020 .................... 109 C901370003 .................... 139
C901360021 .................... 109 C901370004 .................... 139
C901360022 .................... 109 C901370005 .................... 140
C901360023 .................... 110 C901370006 .................... 140
C901360024 .................... 110 C901370007 .................... 140
C901360025 .................... 111 C901380001 .................... 144
C901360026 .................... 111 C901380002 .................... 144
C901360027 .................... 112 C901380003 .................... 145
C901360028 .................... 112 C901380004 .................... 145
C901360029 .................... 113 C901380005 .................... 145
C901360030 .................... 113 C901380006 .................... 146
C901360031 .................... 114 C901380007 .................... 146
C901360032 .................... 114 C901380008 .................... 146
C901360033 .................... 115 C901380009 .................... 147
C901360034 .................... 115 C901380010 .................... 148
C901360035 .................... 116 C901380011 .................... 148
C901360036 .................... 116 C901380012 .................... 148
C901360037 .................... 117 C901380013 .................... 149
C901360038 .................... 117 C901380014 .................... 149
C901360039 .................... 118 C901380015 .................... 150
C901360040 .................... 118 C901390001 .................... 153
C901360041 .................... 119 C901390002 .................... 154
C901360042 .................... 119 C901390003 .................... 154
C901360043 .................... 120 C901390004 .................... 154
C901360044 .................... 120 C901390005 .................... 154
C901360045 .................... 121 C901390006 .................... 155
C901360046 .................... 121 C901390007 .................... 155
C901360047 .................... 122 C901390008 .................... 155
C901360048 .................... 122 C901390009 .................... 155
C901360049 .................... 123 C901390010 .................... 156
C901360050 .................... 123 C901390011 .................... 156
C901360051 .................... 124 C901390012 .................... 156
C901360052 .................... 124 C901390013 .................... 156
C901360053 .................... 125 C901390014 .................... 157
C901360054 .................... 125 C901390015 .................... 157
C901360055 .................... 126 C901390016 .................... 157
C901360056 .................... 126 C901390017 .................... 157
C901360057 .................... 127 C901390018 .................... 158
C901360058 .................... 127 C901390019 .................... 158

Confidential and Proprietary Information of ZTE CORPORATION 215


ZXG10 iBSC (V6.20.10) Performance Counter Reference (Volume V)

C901390020 .....................158 C901400012..................... 173


C901390021 .....................158 C901400013..................... 174
C901390022 .....................159 C901400014..................... 174
C901390023 .....................159 C901400015..................... 174
C901390024 .....................159 C901400016..................... 175
C901390025 .....................159 C901410001..................... 178
C901390026 .....................160 C901410002..................... 178
C901390027 .....................160 C901410003..................... 178
C901390028 .....................160 C901410005..................... 179
C901390029 .....................160 C901410006..................... 179
C901390030 .....................161 C901410007..................... 180
C901390031 .....................161 C901410008..................... 180
C901390032 .....................161 C901420001..................... 183
C901390033 .....................161 C901420002..................... 183
C901390034 .....................162 C901420003..................... 184
C901390035 .....................162 C901420004..................... 184
C901390036 .....................162 C901420005..................... 184
C901390037 .....................162 C901420006..................... 184
C901390038 .....................163 C901420008..................... 185
C901390039 .....................163 C901420009..................... 185
C901390040 .....................163 C901420010..................... 186
C901390041 .....................163 C901420011..................... 186
C901390042 .....................164 C901420012..................... 186
C901390043 .....................164 C901420013..................... 187
C901390044 .....................164 C901420014..................... 187
C901390045 .....................164 C901420015..................... 187
C901390046 .....................165 C901420016..................... 187
C901390047 .....................165 C901420017..................... 188
C901390048 .....................165 C901420018..................... 188
C901390049 .....................165 C901420019..................... 188
C901390050 .....................166 C901420020..................... 189
C901390051 .....................166 C901420021..................... 189
C901390052 .....................166 C901420022..................... 189
C901390053 .....................166 C901420023..................... 190
C901390054 .....................167 C901420024..................... 190
C901390055 .....................167 C901420025..................... 190
C901400001 .....................170 C901420026..................... 191
C901400002 .....................170 C901420027..................... 191
C901400003 .....................171 C901430001..................... 194
C901400004 .....................171 C901430002..................... 194
C901400005 .....................171 C901430003..................... 194
C901400006 .....................172 C901430004..................... 195
C901400007 .....................172 C901440001..................... 197
C901400008 .....................172 C901440002..................... 197
C901400009 .....................173 C901440003..................... 197
C901400010 .....................173 C901440004..................... 198
C901400011 .....................173

216 Confidential and Proprietary Information of ZTE CORPORATION

Potrebbero piacerti anche