Installation Guide

2 Introduction to the BBU3806

Introduction to the BBU3806

About This Chapter


This describes the appearance of, panel of, and engineering specifications for the BBU3806.
2.1 DBS3800 Product Family
This describes the DBS3800 in terms of its function modules and auxiliary facilities.
2.2 Appearance of the BBU3806
The BBU3806 is a case with all its ports on the front panel.
2.3 Panel of the BBU3806
All the ports, Light Emitting Diodes (LEDs), and DIP switch are on the front panel of the
BBU3806.
2.4 Engineering Specifications for the BBU3806
This describes the engineering specifications for the BBU3806.

Issue 01 (2007-09-30)

Huawei Technologies Proprietary

2-1

BBU3806
Installation Guide

2 Introduction to the BBU3806

2.1 DBS3800 Product Family


This describes the DBS3800 in terms of its function modules and auxiliary facilities.

Function Modules of the DBS3800


The BBU3806, BBU3806C, and RRU3801C are referred to as the function modules of the
DBS3800.
Figure 2-1 Function modules of the DBS3800

Function
Module

Connector Type

BBU3806

Indoor baseband unit that processes baseband signals

BBU3806C

Outdoor baseband unit that processes baseband signals

RRU3801C

Outdoor remote radio unit. It receives and transmits RF signals and then
transmits the processed signals to the BBU3806 or BBU3806C.

The BBU3806, BBU3806C, and RRU3801C can be combined into a BTS3803 or BTS3803C.

2-2

BTS3803: consists of one BBU3806, one RRU3801C, and the power system, which
processes RF and baseband signals and applies to indoor environment.

BTS3803C: consists of one BBU3806C and one to three RRU3801Cs, which processes RF
and baseband signals and applies to outdoor environment.

Huawei Technologies Proprietary

Issue 01 (2007-09-30)

BBU3806
Installation Guide

2 Introduction to the BBU3806

Auxiliary Facilities of the DBS3800


Auxiliary
Facility

Connector Type

APM30

An outdoor power backup system providing the following functions:


l

48 V DC power output

Temperature control

A space of 2 U or 7 U for installing user devices based on battery


configurations

For details of the APM30 functions, refer to the APM30 User Guide.
APM100

An outdoor power backup system providing the following functions:


l

48 V DC power output

A maximum of 60 A current

A space of 4 U for user devices

For details of the APM100 functions, refer to the APM100 User Guide.
AFB

An outdoor facility box providing the following functions:


l

Four AC power outputs and four DC power outputs

AC surge protection

Temperature control

Alarm reporting

A space of 5 U for user devices

For details of the AFB functions, refer to the AFB User Guide.
OFB

An outdoor facility box for DC power distribution and transmission,


which provides the following functions:
l

A space of 11 U for user devices

Heat dissipation

Alarm reporting

For details of the OFB functions, refer to the OFB User Guide.
SPD40R

An outdoor AC surge protection device providing the following


functions:
l

AC surge protection

Four AC power outputs

Remote fault alarm reporting

Local fault alarm reporting

For details of the SPD40R functions, refer to the SPD40R User Guide.

Issue 01 (2007-09-30)

Huawei Technologies Proprietary

2-3

BBU3806
Installation Guide

2 Introduction to the BBU3806

Auxiliary
Facility

Connector Type

DPD32-1-6

An indoor facility for DC power distribution, which provides the


following functions:
l

One DC power input at a maximum current of 32 A

Six DC power outputs

For details of the DPD32-1-6 functions, refer to the DPD32-1-6 User


Guide.
An environment monitoring unit providing the following functions:

EMUA

Environment monitoring

Intrusion monitoring

Power distribution monitoring

For details of the EMUA functions, refer to the EMUA User Guide.
Surge Protection
Box for Coaxial
(SPBC)

A small box for indoor application, which provides surge protection for
the coaxial cables of the BBU3806.

Surge Protection
Box for TwistedPair (SPBT)

The surge protection unit in the SPBT is optional.

For details of the SPBC functions, refer to SPBC.

The SPBT without the surge protection unit works as a Digital


Distribution Frame (DDF).

The SPBT with the surge protection unit provides surge protection for
twisted pair cables.

For details of the SPBT functions, refer to SPBT.


Signal Lightning
Protection Unit
(SLPU)

The SLPU protects the E1/T1 signals and Ethernet signals over the
BBU3806 from lightning surge.

DDF

The DDF is used for the E1/T1 cable connections between the BBU3806
and the transmission device. According to installation positions, the DDF
falls into two types, namely external DDF and built-in DDF.

For details of the SLPU functions, refer to SLPU.

For details of the built-in DDF functions, refer to Built-in DDF.

2.2 Appearance of the BBU3806


The BBU3806 is a case with all its ports on the front panel.
Figure 2-2 shows the BBU3806.

2-4

Huawei Technologies Proprietary

Issue 01 (2007-09-30)

BBU3806
Installation Guide

2 Introduction to the BBU3806

Figure 2-2 BBU3806

2.3 Panel of the BBU3806


All the ports, Light Emitting Diodes (LEDs), and DIP switch are on the front panel of the
BBU3806.
Figure 2-3 shows the panel of the BBU3806.
Figure 2-3 Panel of the BBU3806

Table 2-1 describes the ports, LEDs, and DIP switch on the panel of the BBU3806.
Table 2-1 Ports, LEDs, and DIP switch on the panel of the BBU3806
Item

Label

Description

Ports

E1/T1

Ports for Iub transmission

FE0
FE1

Issue 01 (2007-09-30)

CPRI0 to CPRI2

Ports used to connect the BBU3806 to the


RRU3801C, pRRU3801, or RHUB3808

EIa

Ports for BBU3806 interconnection


Huawei Technologies Proprietary

2-5

BBU3806
Installation Guide

2 Introduction to the BBU3806

Item

Label

Description

EIb
EXT_ALM

Port for external alarms

RS485

LEDs

PWR

Port for power supply

GPS

Port for GPS signal input

BITS

Port for clock signal input

10 MHz

Port for clock signal output

8 kHz/TTI

Port for testing

ETH_RS232

Port for commissioning

RST

Button used to reset the BBU3806

ESD

Port used to connect the ESD wrist strap

RUN

For details, refer to LEDs on the BBU3806.

ALM
ACT
LIU0 to LIU7
CPRI0 to CPRI2
DIP switch

TYPE
LOCAT_ID

For details, refer to DIP Switch on the


BBU3806.

E1/T1

2.4 Engineering Specifications for the BBU3806


This describes the engineering specifications for the BBU3806.

Physical Dimensions
The dimensioning of the BBU3806 is 436 mm x 300 mm x 42 mm (W x D x H).

Weight
The weight of the BBU3806 is 5 kg at most.

2-6

Huawei Technologies Proprietary

Issue 01 (2007-09-30)

BBU3806
Installation Guide

2 Introduction to the BBU3806

Power Input
Table 2-2 Power input to the BBU3806
Rated Voltage

Operating Voltage Range

48 V DC

40 V DC to 60 V DC

+24 V DC

+19 V DC to +29 V DC

Power Consumption
l

The maximum power consumption of the BBU3806 without the plugboard is 60 W.

The maximum power consumption of the BBU3806 with the plugboard is 80 W.