Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
A10VO (US-Version)
Data sheet
Series 52/53
Size NG10 to 100
Nominal pressure 3600 psi (250 bar)
Peak pressure 4600 psi (315 bar)
Open circuits
Series 52
Series 53
Features
Contents
Type code for standard program
Technical data
10
DR Pressure control
12
The flow is proportional to the drive speed and the displacement. The flow can be steplessly varied by adjusting the
swashplate angle.
13
14
15
EP Electro-proportional control
16
Low noise
20
21
22
50
Power control
54
55
Installation instructions
56
General instructions
60
2/60
RA-A 92703/12.11
02
03
04
5
05
06
07
08
09
10
11
12
10 18 28 45 601) 63 85 100
l A10VS
A10V
Operation mode
02 Pump, open circuit
Size (NG)
10 18 28 45 601) 63 85 100
Control device
Pressure control
DR
l3)
DFR
l2)
DRF
l3)
DFR1
l l2) l
DRS
m EF.D.4)
U = 12 V
ED71
U = 24 V
ED72
U = 12 V
l ER715)
U = 24 V
l ER725)
(10 to 35 bar)
LA5D
(36 to 70 bar)
LA6D
LA7D
LA8D
LA9D
X-T plugged
negative characteristic
positive characteristic
DRG
remotely operated
Start of control
see LA.D
l LA.DG
Start of control
see LA.D
l LA.DS
Start of control
see LA.D
LA.S
Series 52 units are delivered as standard with 3.66 in3 (60 cm3). Higher values on request.
Series 53 only with D flange
3) Series 52 only with C flange
4) See RE 92709
5) The following must be taken into account during project planning:
Excessive current levels (I > 1200 mA with 12 V or I > 600 mA with 24 V) to the ER solenoid can result in undesired increase
of pressure which can lead to pump or system damage:
- Use Imax current limiter solenoids.
- An intermediate plate pressure controller can be used to protect the pump in the event of overflow.
An accessory kit with intermediate plate pressure controller can be ordered from Bosch Rexroth under part number R902490825.
1)
2)
= available
m = on request
= not available
RA-A 92703/12.11
3/60
02
03
04
05
06
07
08
09
10
11
12
10 18 28 45 601) 63 85 100
Electro-proportional control (positive characteristic) with
pressure control
04
05
06
U = 12 V
EP1D
U = 24 V
EP2D
U = 12 V
m EP1DF
U = 24 V
m EP2DF
U = 12 V
m EP1DS
U = 24 V
m EP2DS
U = 12 V
m EP1ED
U = 24 V
m EP2ED
m EK1DF
m EK2DF
m EK1DS
m EK2DS
U = 12 V
m EK1ED
U = 24 V
m EK2ED
Series
Series 5, index 2
522)
Series 5, index 3
533)4)
Direction of rotation
With view on drive shaft
clockwise
counter clockwise
Seals
07 FKM (fluor-caoutchouc)
V
10 18 28 45 601) 63 85 100
Drive shaft
Splined shaft
ANSI B92.1a
08
standard shaft
K7)
C7)
Series 52 units are delivered as standard with 3.66 in3 (60 cm3). Higher values on request.
2) Control DR, DFR, DFR1, DRG, ED and ER: delivery with size 10, 28, 45, 60 and 856) only in series 52
3) Control DR, DRF, DRS, DRG, ED and ER: delivery with size 18, 63, 855) and 100 only in series 53
4) Control EF., LA.., EP.. and EK.. Delivery with size 18 to 100 only in series 53
5) Control DRF and DRS: delivery with size 85 only with D flange in series 53
6) Control DFR, DFR1: delivery with size 85 only with C flange in series 52
7) only series 52
1)
= available
m = on request
= not available
4/60
RA-A 92703/12.11
02
03
Mounting flange
ISO 3019-1 (SAE)
04
05
06
07
08
09
10
11
12
10 18 28 45 601) 63 85 100
2-bolt
4-bolt
l
l
l2)
10 18 28 45 601) 63 85 100
61
62
64
10 18 28 45 601) 63 85 100
l l l l l l l l
N00
shaft3 )
Diameter
diameter
82-2 (A)
5/8 in
9T 16/32DP
K01
3/4 in
11T 16/32DP
K52
7/8 in
13T 16/32DP
K68
1 in
15T 16/32DP
K04
K15
K16
K07
K24
11 101-2 (B)
127-4 (C)
127-2 (C)
10 18 28 45 601) 63 85 100
l l l l l l l
Series 52 units are delivered as standard with 3.66 in3 (60 cm3). Higher values on request.
2) Only available in series 53. For controller designation and series assignment, please refer to positions 04, 05,
including footnotes.
3) Coupling for splined shaft as per ANSI B92.1a
1)
= available
m = on request
= not available
RA-A 92703/12.11
5/60
Technical data
Hydraulic fluid
Selection diagram
-4
32
68
-40
1600
1000
600
400
-20
20
40
200
500
100
300
60
200
40
100
80
20
60
10
80 100 C
1600 7400
0
10
VG 68
VG 46
VG 32
VG 22
VG
Viscosity n
-40
1000
SUS mm 2/s
42
5
-40
-25
10 0 10
30
50
-40
-13
14 32 50
86
70
Temperature t
Fluid temperature range
90
The finer the filtration the better the fluid cleanliness class and
the longer the service life of the axial piston unit.
In order to guarantee the functional reliability of the axial piston
unit it is necessary to carry out a gravimetric evaluation of the
fluid to determine the particle contamination and the cleanliness class according to ISO 4406. A cleanliness class of at
least 20/18/15 must be achieved.
At very high hydraulic fluid temperatures (195 F (90 C) to maximum 239 F (115 C)), a cleanliness class of at least 19/17/14
according to ISO 4406 is necessary.
60
Important
The case drain temperature is influenced by pressure and input
speed and is always higher than the reservoir temperature.
However, at no point in the component may the temperature
exceed 239 F (115 C). The temperature difference specified
on the left is to be taken into account when determining the
viscosity in the bearing.
7400
4600
3000
2000
36
170
16
80
mm 2/s SUS
5
42
115 C
240 F
6/60
RA-A 92703/12.11
Technical data
Operating pressure range
Pressure at service line port B
Definition
pnom
Dt
Dp
Time t
Pressure at suction port S (inlet)
Minimum pressure pS min____________ 10 psi (0.8 bar) absolute
Maximum pressure pS max _____________75 psi (5 bar) absolute
Case drain pressure
Maximum permissible case drain pressure
(at port L, L1):
Maximum 7.5 psi (0.5 bar) higher than the inlet pressure at port
S, however not higher than 30 psi (2 bar) absolute.
Pressure p
t1
t2
tn
1.2
23 (1.6)
20 (1.4)
1.1
17.5 (1.2)
14.5 (1.0)
1.0
13
0.9
0.7
0.8
0.9
(0.9)
11.5 (0.8)
1.0
Time t
Total operating period = t1 + t2 + ... + tn
RA-A 92703/12.11
Notes
7/60
8/60
RA-A 92703/12.11
Technical data
Table of values (theoretical values, without efficiencies and tolerances: values rounded)
Size
NG
Geometrical displacement Vg max
per revolution
10
18
28
45
601)
632)
85
100
in3
0.64
1.10
1.75
2.75
3.66
3.84
5.18
6.10
(cm3)
(10.5)
(18)
(28)
(45)
(60)
(63)
(85)
(100)
rpm
3600
3300
3000
26004)
2600
2600
2500
2300
4320
3960
3600
3120
3140
3140
3000
2500
Flow
at nnom and Vg max
gpm
9.7
15.6
22
31
41
43
55
60
(l/min)
(37)
(59)
(84)
(117)
(156)
(163)
(212)
(230)
7.1
1.1
18
24
25.1
34
39
(15)
(27)
(42)
(68)
(90)
(95)
(128)
(150)
Speed3)
maximum at Vg max
at nE = 1500 rpm
and Vg max
nnom
qv max
65 (49)
88 (65)
90 (68)
119 (89)
130 (96)
38
50
52
71
84
(11)
(18)
(28)
(37)
(39)
(53)
(62)
31
52
82
132
175
184
247
293
(Nm)
(42)
(71)
(111)
(179)
(238)
(250)
(338)
(398)
lb-ft
13
21
33
53
70
74
102
117
(Nm)
(17)
(29)
(45)
(72)
(95)
(100)
(135)
(159)
lb-ft/rad
6760
8082
16400
37500
48100
48100
105100
105100
(11000)
(22300) (37500)
(65500)
(65500)
(143000) (143000)
10870
19400
51200
51200
(14800)
5870
22130
(8000)
(30000) (49200)
(49200)
(102900) (102900)
25370
39830
39830
86960
(34400)
(54000)
(54000)
(117900) (117900)
19770
32380
54506
S
Rotary
stiffness,
drive
R
shaft
U
lb-ft/rad
K/C
lb-ft/rad
(Nm/rad) (9200)
lb-ft/rad
(Nm/rad)
lb-ft/rad
5020
(Nm/rad) (6800)
(Nm/rad)
7965
30240
36290
(69400)
36390
75900
75900
86960
(Nm/rad) (10800)
lbs-ft2
0.0142
0.0403
0.1329
0.2848
0.2848
(kgm2)
(0.012)
rad/s2)
8000
6800
5500
4000
3300
3300
2700
2700
gal
0.05
0.06
0.08
0.13
0.21
0.21
0.26
0.26
(L)
(0.2)
(0.25)
(0.3)
(0.5)
(0.8)
(0.8)
(1)
(1)
lbs (kg)
17 (8)
25 (11.5) 31 (14)
40 (18)
JTW
47 (35)
24
lb-ft
c
c
34 (25)
15
0.2207
0.0783
0.1329
75 (34)
Only series 52
Only series 53
3) The values are applicable:
- for absolute pressure pabs = 15 psi (1bar) at the suction port S
- for the optimum viscosity range of nopt=80 to 170 SUS (16 to 36 mm2/s)
- for mineral-based operating materials with a specific mass of 0.88 kg/l.
4) Please contact us regarding higher speeds
5) The scope of application lies between the minimum necessary and the maximum permissible drive speeds.
Valid for external excitation (e.g. diesel engine 2- to 8-fold rotary frequency, cardan shaft 2-fold rotary frequency). The limiting
value is only valid for a single pump. The loading capacity of the connecting parts must be taken into account.
1)
2)
RA-A 92703/12.11
9/60
Technical data
Note
Exceeding the maximum or falling below the minimum permissible values on page 8 can lead to a loss of function, a reduction in
operational service life or total destruction of the axial piston unit. We recommend checking the loading with tests or calculations /
simulations and comparison with the permissible values.
Determination of size
Flow
qV =
Torque
Power
Vg n hV
[gpm (l/min)]
231 (1000)
Vg Dp
[lb-ft (Nm)]
24 (20) p hmh
2p T n
33.000 (60000)
qV Dp
1.714 (600) ht
[HP (kW)]
Vg
Dp
Speed in rpm
hV
Volumetric efficiency
hmh
Mechanical-hydraulic efficiency
ht
10/60
RA-A 92703/12.11
Technical data
Permissible radial and axial forces on the drive shaft
Size
NG
10
18
28
45
60/63
85
100
Fq max
lbf
(N)
56
(250)
78
(350)
270
(1200)
337
(1500)
382
(1700)
450
(2000)
450
(2000)
+ Fax max
lbf
(N)
90
(400)
157
(700)
225
(1000)
337
(1500)
450
(2000)
675
(3000)
675
(3000)
Fq
a/2 a/2
a
NG
10
lb-ft (Nm) 31 (42)
18
28
45
60/63
85
100
52 (71)
82 (111)
132 (179)
184 (250)
198
319
630
1157
1157
DIA
7/8
1 1/4
1 1/2
1 1/2
in
3/4
3/4
DIA
3/4
in
7/8
1 1/4
43 (59)
DIA
5/8
7/8
1 1/4
in
5/8
1 1/4
DIA
7/8
C3)
in
in (mm)
0.750
(19.05)
1 1/4
1 1/4
0.8750
(22.225)
1.000
(25.4)
107 (145)
1.2500
(31.75)
80 (108)
118 (160)
89 (120)
130 (176)
2)
Distribution of torques
T1
T2
TE
1. Pumpe
Pump 1
2. Pumpe2
Pump
TD
RA-A 92703/12.11
11/60
Technical data
Drive power and flow
Operating material:
Hydraulic fluid ISO VG 46 DIN 51519, t = 50 C
7.5
(25)
qV
pqV max
(15)
2.5
(5)
0
pqV min
(50)
(100)
1000
(150)
(200)
(40)
(30)
(20)
0
qV
50
(30)
40
(10)
pqV min
(50)
(100)
1000
(150)
20
(0) 0
(250) (bar)
(200)
50
45
40
2000
3000 3625 psi
Operating presure p
10 (40)
5 (20)
(50)
0
(100)
1000
(150)
2000
(200)
(20)
(10)
Pqv min
(30) 40
Flow qv
Pqv max
20
0
(250) (bar)
Pqv min
5 (20)
0
(50)
0
(100)
1000
(150)
2000
(200)
60
(80)
(140)
(70)
(120)
(60)
(100)
(40)
(20)
(20)
pqV 0
(10)
HP
146
140
120
100
80
60
40
20
0
(100)
1000
(150)
(200)
2000
Operating pressure
(250) (bar)
35
30
25
(kW)
(110)
qV
(100)
(90)
(180)
(160)
(80)
(140)
(70)
(60)
(120)
pqV max
(100)
15
(60)
10
(40)
(20)
0
(250)(bar)
(40)
10
(20)
20
(50)
pqV max
(80)
20
(10)
(90)
(160)
(30)
40
Flow qV
Flow q v
(180)
(30) 40
Operating pressure p
(kW) HP
(60) 80
(50)
(100)
(60)
45
(40)
(kW)
(110)
gpm (L/min)
60 (230)
58 (220)
55 (200)
n = 2600 rpm
Pqv max
15
50
15 (60)
10 (40)
20
0
(250) (bar)
(200)
2000
(10)
Size 100
n = 1500 rpm
n = 2300 rpm
qv
1000
(150)
qV
n = 1500 rpm
gpm (L/min)
(120)
30
(100)
25
20 (80)
(100)
(50)
Size 45
(50)
(20)
Operating pressure p
30
20
(kW) HP
60
(40)
qv
35
25
n = 1500 rpm
n = 3000 rpm
gpm (L/min)
23.8 (90)
20 (80)
15 (60)
Pqv min
gpm (L/min)
58 (220)
55 (200)
Size 28
60
Size 85
n = 1500 rpm
n = 2500 rpm
(40)
(20)
pqV max
(20)
(40)
Operating pressure p
Drive power P qV
Flow qV
10
(50)
(30) 40
(kW) HP
(60)
(50)
(40)
2000
3000 3625 psi
Operating presure p
(L/min)
15
(60)
10
(250) (bar)
Size 18
n = 1500 rpm
n = 3300 rpm
gpm
15
(60) 80
Pqv max
Drive power P qV
(35)
Flow qV
Flow qV
10
(kW) HP
30
(20) 25
(15) 20
(10) 15
10
(5)
5
0
qv
(50)
(40)
(80)
(30)
pqV 0
(20)
(10)
HP
146
140
120
100
80
60
40
20
0
0
(50)
0
1000
(100)
(150)
2000
Operating pressure
(200)
(250) (bar)
Drive power P qV
(L/min)
Drive power P qV
gpm
(kW) HP
(80)
100
(70)
gpm (L/min)
(160)
40
(140)
35
(120)
30
(100)
25
20 (80)
Flow q v
Size 10
n = 1500 rpm
n = 3600 rpm
Size 60/63
n = 1500 rpm
n = 2600 rpm
12/60
RA-A 92703/12.11
DR Pressure control
The pressure control limits the maximum pressure at the pump
output within the pump control range. The variable pump only
supplies as much hydraulic fluid as is required by the consumers. If the operating pressure exceeds the target pressure set
at the pressure valve, the pump will regulate towards a smaller
displacement. The pressure can be set steplessly at the control
valve.
Circuit diagram
Static characteristic
L L1
L2
Setting range1)
Operating pressure pB
psi (bar)
3600 (250)
290 (20)
1)
Service line
Suction line
L, L1,2
Controller data
Hysteresis and repeatability p_______ maximum 45 psi (3 bar)
Pressure rise, maximum
NG
10
18
28
45
60/63
85
100
psi
90
(bar) (6)
90
(6)
90
(6)
90
(6)
115
(8)
175
(12)
200
(14)
RA-A 92703/12.11
13/60
Circuit diagram
Not included in the delivery contents
The differential pressure at the control valve is set as standard to 290 psi (20 bar). The control fluid volume at port X is
approx. 0.4 gpm (1.5 l/min). If another setting is required (range
from 145 to 320 psi (10 to 22 bar)) please state this in clear
text.
As a separate pressure relief valve we can recommend:
DBDH 6 (hydraulic) to RE 25402 or
L L1
L2
Setting range1)
Operating pressure pB
psi (bar)
3600 (250)
290 (20)
Port for
B
Service line
Suction line
L, L1,2
Pilot pressure
NG
p
psi
(bar)
10
18
28
45
60/63
85
100
90
(6)
90
(6)
90
(6)
90
(6)
115
(8)
175
(12)
200
(14)
14/60
RA-A 92703/12.11
L L1
Static characteristic
Flow control at n1 = 1500 rpm; tfluid = 120 F (50 C))
Hysteresis / pressure rise pmax
Setting range1)
Operating pressure pB
psi (bar)
3625 (250)
290 (20)
L2
Port for
B
Service line
Suction line
L, L1,2
Pilot pressure
Differential pressure p
Speed n [rpm]
Flow qv [l/min]
10
18
28
45
gpm
0.13
(l/min)
(1.8)
60/
63
85
100
0.83 0.83
(2.5) (3.1)
(3.1)
RA-A 92703/12.11
15/60
In order to achieve a constant drive torque with varying operating pressures, the swivel angle and with it the output flow from
the axial piston pump is varied so that the product of flow and
pressure remains constant.
Controller data
For pressure controller DR data, see page 12.
For flow control FR data, see page 13.
Controller data
Maximum control fluid consumption, see page 14
Volume flow loss at qVmax, see page11.
Start of
control
Order code
[psi ((bar)]
18
28
45
63
85
100
145 to 510
(10 to 35)
2.80 - 8.92
(3.8 - 12.1)
4.4 - 14
(6 - 19)
7.4 - 22.1
(10 - 30)
11 - 32
(15 - 43)
15 - 42
(20 - 57)
18 - 49.5
(24 - 68)
LA5
520 to 1015
(36 to 70)
8.92 - 17.2
(12.2 - 23.3)
14 - 26.5
(19.1 - 36)
22.2 - 43.5
(30.1 - 59)
32 - 61
(43.1 - 83)
42 - 83
(57.1 - 112)
49.5 - 97.1
(68.1 - 132)
LA6
1030 to 1520
(71 to 105)
17.2 - 24.9
(23.4 - 33.7)
26.6 - 38.4
(36.1 - 52)
43.6 - 62
(59.1 - 84)
61 - 88
(83.1 - 119)
83 - 118)
(112.1 - 160)
97.1 - 139.4
(132.1 - 189)
LA7
1535 to 2030
(106 to 140)
24.9 - 33.2
(33.8 - 45)
38.4 - 51.6
(52.1 - 70)
62 - 83
(84.1 - 112)
88 - 116
(119.1 - 157)
118 - 156
(160.1 - 212)
139.4 - 183.6
(189.1 - 249)
LA8
2045 to 3335
(141 to 230)
33.2 - 55.2
(45.1 - 74.8)
51.7 - 86.3
(70.1 - 117)
83 - 139
(112.1 - 189)
116 - 195
(157.1 - 264)
156 - 263
(212.1 - 357)
183.3 - 309
(249.1 - 419)
LA9
T
3.5 (6.4)
or
P=
Operating pressure pB
2p T n
33.000 (60000)
psi (bar)
4350 (300)
3620 (250)
2900 (200)
LA9
2175 (150)
LA8
1450 (100)
LA7
725
(50)
(0)
Not included
in the delivery
contents
LA6
100
LA5
qV
LA9
(see table
on page 14)
LA8
Not included
in the delivery
contents
LA7
LA6
L1
LA5
0
100
L2
16/60
RA-A 92703/12.11
EP Electro-proportional control
Electro-proportional control makes a stepless and reproducible setting of the pump displacement possible directly via the
swashplate. The control force of the control piston is applied
by a proportional solenoid. The control is proportional to the
current (for start of control, see table right).
In a depressurized state, the pump is swiveled to its initial position (Vg max) by an adjusting spring. If the operating pressure
exceeds 200 psi (14 bar), the pump will swivel from Vg max to
Vg min without control by the solenoid (control current < start of
control). A PWM signal is used to control the solenoid.
EP.D: The pressure control regulates the pump displacement
back to Vg min after the set target pressure has been reached.
A minimum operating pressure of 200 psi (14 bar) is needed
for control. The necessary control fluid is taken from the high
pressure.
Circuit diagram EP.D
EP1
EP2
Voltage
12 V (20 %) 24 V (20 %)
Control current
Start of control at Vg min
400 mA
200 mA
1200 mA
600 mA
Limiting current
1.54 A
0.77 A
Nominal resistance (at 68 F
5.5
22.7
(20 C))
Dither frequency
100 to
100 to
200 Hz
200 Hz
Actuated time
100 %
100 %
For protection rating, please refer to "Socket version"
on page 55
Operating temperature range at valve -4 F to 239 F
(-20 C to +115 C)
Characteristic EP1/2
Hysteresis < 5 %
L1 L
1400
L2
1200
Port for
B
Service line
Suction line
L, L1,2
Control pressure
1000
EP1
800
600
EP2
400
200
0
Vg min
0,5
Displacement [%]
1,0
Vg max
Note
The spring return at the controller is not a safety device
Dirt contamination (contaminated hydraulic fluid, wear or residual dirt from system components) could cause the controller
to stick in an undefined position. The volume flow of the axial
piston unit will then no longer follow the commands of the
operator.
Check whether remedial measures for your application are
needed on your machine in order to put the driven consumer
in a safe state (e.g. immediate stop).
RA-A 92703/12.11
17/60
EK1
EK2
Voltage
12 V (20 %) 24 V (20 %)
Control current
Start of control at Vg min
400 mA
200 mA
1200 mA
600 mA
Limiting current
1.54 A
0.77 A
Nominal resistance (at 68 F
5.5
22.7
(20 C))
Dither frequency
100 to
100 to
200 Hz
200 Hz
Actuated time
100 %
100 %
For protection rating, please refer to "Socket version"
on page 55
Operating temperature range at valve -4 F to 239 F
(-20 C to +115 C)
Characteristic EK
Hysteresis < 5 %
1400
X
L1 L
Ires
1200
1000
EK1
800
600
Imin
Ioff
400
Imin
200
L2
Ioff
Port for
B
Service line
Suction line
L, L1,2
Control pressure
Note
The spring return at the controller is not a safety device
Dirt contamination (contaminated hydraulic fluid, wear or residual dirt from system components) could cause the controller
to stick in an undefined position. The volume flow of the axial
piston unit will then no longer follow the commands of the
operator.
Check whether remedial measures for your application are
needed on your machine in order to put the driven consumer
in a safe state (e.g. immediate stop).
Ires
EK2
0,5
Displacement [%]
1,0
Vg min
Vg max
EK1.
EK2.
Imin [mA]
400
200
Imax [mA]
1200
600
Ioff [mA]
< 300
< 150
Ires [mA]
> 1200
> 600
18/60
RA-A 92703/12.11
L1 L
L2
Port for
Circuit diagram EP.D
L1 L
Service line
Suction line
L, L1,2
Control pressure
L2
Not included
in the delivery
contents
L1 L
L2
Port for
B
Service line
Suction line
L, L1,2
Port for
B
Service line
Suction line
L, L1,2
Control pressure
RA-A 92703/12.11
L1 L
L2
As the solenoid current signal drops towards zero, the pressure will be limited to pmax by an adjustable hydraulic pressure
cut-off (negative characteristic, e.g. for fan drives ). A PWM
signal is used to control the solenoid.
For further information and technical data of the solenoids for
ED(ER) control please refer to pages 20 and 21.
Static current-pressure characteristic ED
(negative characteristic)
(measured with pump in zero stroke)
Port for
Operating pressure P
psi (bar)
3600 (250)
Max. adjustable
control pressure
Service line
Suction line
L, L1,2
Control pressure
2000 (140)
(0)
Amperage
I/ I max
Setting range
Operating pressure pB
psi (bar)
3600 (250)
290 (20)
L1 L
L2
S
Port for
Service line
Suction line
Controller data
L, L1,2
Control pressure
19/60
20/60
RA-A 92703/12.11
As the solenoid current signal drops towards zero, the pressure will be limited to pmax by an adjustable hydraulic pressure
cut-off (secure fail safe function in case of a loss of power, e.g.
for fan drives ).
The response time characteristic of the ED-control was optimized for the use as a fan drive system.
When ordering, state the type of application in clear text.
L1
Operating pressure P
psi (bar)
3600 (250)
Port for
Max. adjustable
control pressure
Service line
Suction line
L, L1
2000 (140)
(0)
Amperage
I/ I max
min
Setting range
Operating pressure P
2000 (140)
ED71
Voltage
12 V (20 %) 24 V (20 %)
ED72
Control current
Flow qv [l/min]
min
max
Controller data
Standby standard setting 290 psi (20 bar), other values on
request.
Hysteresis and pressure rise_ ___________ p < 60 psi (4 bar).
Control flow consumption______ 0.8 to 1.2 gpm (3 to 4.5 l/min).
100 mA
50 mA
1200 mA
600 mA
Limiting current
1.54 A
0.77 A
Nominal resistance (at 68 F
5.5
22.7
(20 C))
Dither frequency
100 to
100 to
200 Hz
200 Hz
Actuated time
100 %
100 %
For protection rating, please refer to "Socket version"
on page 55
Operating temperature range at valve -4 F to 239 F
(-20 C to +115 C)
RA-A 92703/12.11
21/60
As the solenoid current signal drops towards zero, the pressure will be limited to pmin (stand by).
Operating pressure P
psi (bar)
5100 (350)
L1
3600 (250)
Max. adjustable
control pressure
2200 (150)
725
(50)
(0)
Min.
adjustable
control
pressure
0
Amperage
1
I/Imax
Port for
B
Service line
Suction line
L, L1
ED71
Voltage
12 V (20 %) 24 V (20 %)
2000 (140)
min
Control current
Hysteresis / pressure rise p
Setting range
Operating pressure P
min
ED72
Flow qv [l/min]
max
Controller data
Standby standard setting 200 psi (14 bar), other values on
request.
Hysteresis and pressure rise_ ___________ p < 60 psi (4 bar).
Control flow consumption______ 0.8 to 1.2 gpm (3 to 4.5 l/min).
100 mA
50 mA
1200 mA
600 mA
Limiting current
1.54 A
0.77 A
Nominal resistance (at 68 F
5.5
22.7
(20 C))
Dither frequency
100 to
100 to
200 Hz
200 Hz
Actuated time
100 %
100 %
For protection rating, please refer to "Socket version"
on page 55
Operating temperature range at valve -4 F to 239 F
(-20 C to +115 C)
22/60
Dimensions, size 10
RA-A 92703/12.11
(5
6
2.87 (73)
20
L1
4.19 (106.4)
5.28 (134)
0.94 (24)
5.83 (148)
7.09 (180)
1.13 1.13
(28.6)(28.6)
2.00 (51) 2.00 (51)
DRG
L1
7.05 (179)
For details of connection options and drive shafts, please refer to page 23
5.75 (146)
L
L1
7.05 (179)
3.74 (95)
4.02 (102)
3.74 (95)
4.02 (102)
1.13 1.13
(28.6)(28.6)
2.00 (51) 2.00 (51)
DFR / DFR1
5.75 (146)
DIA 0.43
2.11 (53.5) ( 11)
2.20 (56)
45
DIA 3.250
3.248
0
)
( 82.55 -0.054
35
0. )
(9
45
Flange
ISO 3019-1
2.
0.43 (11)
0.25 (6.4)
RA-A 92703/12.11
Dimensions, size 10
23/60
Drive shaft
Splined shaft 3/4 in
11T 16/32DP1) (SAE J744)
1.18 (30)
0.87
(21)
Centering4)
R12 x 0.26
DIN 332
1.50 (38)
0.62
(15.8)
1.13
(28.6)
Centering4)
R 0.12x0.26
DIN 332
1.25 (31.8)
0.750
0.749
0.01(2.5)
(19.05-0.02)
0.94 (23.8)
0.35 (14)
0.19
(5)
DIA
1/4-20UNC-2B2) 3)
1.30 (33)
0.31 (8)
1.61(41)
Ports
Standard
Size3)
Designation
Port for
Service line
ISO 11926
4600 (315)
Suction line
ISO 11926
75 (5)
ISO 119266)
30 (2)
O7)
L1
ISO
119266)
30 (2)
X7)
Pilot pressure
ISO 119265)
4600 (315)
ANSI B92.1a, 30 pressure angle, flat root, side fit, tolerance class 5
2) Thread according to ASME B1.1
3) For the maximum tightening torques the general instructions on page 60 must be observed.
4) Coupling axially secured, e.g. with a clamp coupling or radially mounted clamping screw
5) Depending on the application, momentary pressure spikes can occur. Consider this when selecting measuring equipment and
fittings.
6) The spot face can be deeper than as specified in the standard.
7) Depending on the installation position, L or L1 must be connected (please refer to pages 56 and 57)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
1)
24/60
RA-A 92703/12.11
3.27 (83)
0.39 (10)
0.96 (24.5)
L1
0.
09
(2
)
.5
(6
1.
5)
45
(6
1.
5)
2.
42
X
2.48 (63)
0.43 (11)
42
L1
DIA 3.250
3.248
(82.55 - 00.054 )
Flange
ISO 3019-1
2.
0.31 (7.8)
4.80 (122)
2.83 (72)
Port plate 61
45
L2
3.27 (83)
6.14 (156)
max. 7.20 (183)
4.19 (106.4)
5.35 (136)
2.31 (58.7)
DIA 1.26
(32)
DIA 0.79
(20)
1.87 (47.6)
View X
0.87 (22.2)
1.19 (30.2)
1.26 1.30
Detail Z
(32) (33)
Port plate 62
DIA 3.250
3.248
(82.55 - 00.054 )
1.87 (47.6)
DIA 0.79
(20)
Flange
ISO 3019-1
3.27 (83)
0.39 (10)
L1
View Y
0.87
(22.2)
L
(32)
DIA 1.26
2.31 (58.7)
0.31 (7.8)
0.96 (24.5)
S
5.63 (143)
6.70 (170)
1.19
(30.2)
Dimensions of service line ports turned through 180 for counter-clockwise rotation
For details of connection options and drive shafts, please refer to page 25
1)
RA-A 92703/12.11
Dimensions, size 18
25/60
Drive shaft
Splined shaft 3/4 in
11T 16/32DP1) (SAE J744)
1.18 (30)
1/4-20UNC-2B3) 4)
1/4-20UNC-2B3) 4)
0.35 (14)
0.20 (5)
0.87
(21)
0.55 (14)
Usable
shaft length
0.94 (23.8)
0.20 (5)
0.83 (21)
Centering5)
R 0.12 x 0.26
DIN 332
0.62
(15.8)
1.50 (38)
1.50
(38)
1.25 (31.8)
Ports
Designation
Port for
Standard
Size4)
Service line,
fixing thread
SAE J518
ASME B1.1
3/4 in
3/8-16UNC-2B; 0.75 (19) deep
4600 (315)
Suction line,
fixing thread
SAE J518
ASME B1.1
1 1/4 in
7/16-14UNC-2B; 0.79 (20) deep
75 (5)
ISO 119267)
30 (2)
O8)
L1, L2
ISO 119267)
30 (2)
X8)
Pilot pressure
ISO
119267)
ANSI B92.1a, 30 pressure angle, flat root, side fit, tolerance class 5
Splines according to ANSI B92.1a, run out of spline is a deviation from standard
3) Thread according to ASME B1.1
4) For the maximum tightening torques the general instructions on page 60 must be observed
5) Coupling axially secured, e.g. with a clamp coupling or radially mounted clamping screw
6) Depending on the application, momentary pressure spikes can occur. Keep this in mind when selecting measuring equipment
and fittings
7) The spot face can be deeper than as specified in the standard
8) Depending on the installation position, L, L1 or L2 must be connected (please refer to installation instructions on pages 56, 57)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
1)
2)
Dimensions, size 18
DRG
EP.D. / EK.D.
8.60 (218.5)
4.45 (113)
2.44 (62)
X
L2
L2
2.44 (62)
X
8.66 (220)
4.80 (122)
4.17 (106)
L1
L1
L
L2
L2
LA.D.
ED7. / ER7.
8.42 (214)
X 2.44 (62)
4.80 (122)
1)
L1
4.80 (122)
4.45 (113)
4.17 (106)
1)
EP.ED / EK.ED
L1
DRF/DRS
8.86 (225)
4.45 (113)
2.44 (62)
4.80 (122)
4.17 (106)
4.80 (122)
4.17 (106)
L1
RA-A 92703/12.11
4.80 (122)
4.33 (110)
26/60
L2
ER7.: 6.18 inches (157 mm) if using an intermediate plate pressure controller.
L2
L1
L
RA-A 92703/12.11
27/60
Flange
ISO 3019-1
45
4.86 (123.5)
0.25 (6.3)
9)
4.000
3.998
0
(101.6 -0.054
)
2.
72
2.87 (73)
2.60 (66)
DIA
(6
1.06 (27)
0.31 (7.9)
L1
5.75 (146)
6.77 (172)
6.79 (170)
Port plate 62
1.30
(33)
0.47 (12)
0.37 (9.5)
1.87 (47.6)
DIA 0.79 (20)
0.25 6.3)
Flange
ISO 3019-1
View X
Port plate 61
2.31 (58.7)
DIA 1.26 (32)
View X
Port plate 64
1.30
(33)
0.56 (14.3)
0.37 (9.5)
1.19 (30.2)
1.30
(33)
Detail Z
0.87 (22.2)
1.30
(33)
View Y
B
0.87 (22.2)
2.31 (58.7)
(32)
DIA 1.26
DIA 4.000
3.998
0
(101.6 -0.054
)
L
Y
S
1.06 (27)
1)
2)
L1
6.30 (160)
1.19
(30.2)
2.60 (66)
2.60 (66)
Dimensions of service line ports turned through 180 for counter-clockwise rotation (please refer to page 28)
Primary dimensions for pump apply for series 52 and 53
28/60
Dimensions, size 28
RA-A 92703/12.11
Drive shaft
1/4-20UNC-2B3) 4)
1.30 (33.1)
0.63 (16)
0.20(5)
0.63 (16)
0.20(5)
Usable
shaft length 0.99 (25)
0.99
(25.1)
1.31 (33.3)
1.13 (28.6)
0.63
0.259 (6.35+0.25 )
0.250
DIA 0.98
(25)
1/4-20UNC-2B3)4)
0.9843
DIA 0.8750
0.9764
0.8742
(25 -0.2) (22.225 - 0.02 )
(16)
1.62 (41.3)
1.61 (41)
1.61 (41)
0.75
(19)
0.118 0.87
0.110 (22)
(3-0,2)
0.251(6.35+0.025)
0.250
A
B
0.57
(14.4)
2.19 (55.6)
0.130(3.2+0.1)
0.126
DIA 0.8575
0.8570
0.16 (4)
Section A-B
0.251(6.35+0.025)
0.250
DIA 0.749
(19.024)
(21.774 +0.006
0.006 ) DIA 0.863
(21.91)
5/8-18UNF-2A3)
Taper
125:1000
Ports
Designation
Port for
Standard
Size4)
Service line,
fixing thread
SAE J518
ASME B1.1
3/4 in
3/8-16UNC-2B; 075 (19) deep
4600 (315)
B; Port plate 64
threaded
ISO 119267)
4600 (315)
Suction line,
fixing thread
SAE J518
ASME B1.1
1 1/4 in
7/16-14UNC-2B; 0.79 (20) deep
75 (5)
S; Port plate 64
threaded
ISO 119267)
75 (5)
119267)
30 (2)
O9)
30 (2)
X9)
4600 (315)
ISO
L1, L28)
ISO 119267)
Control pressure
ISO
119267)
ANSI B92.1a, 30 pressure angle, flat root, side fit, tolerance class 5
Splines according to ANSI B92.1a, run out of spline is a deviation from standard.
3) Thread according to ASME B1.1
4) For the maximum tightening torques the general instructions on page 60 must be observed.
5) Only series 52
6) Depending on the appl., momentary press. spikes can occur. Consider this when selecting measuring equipment and fittings.
7) The spot face can be deeper than as specified in the standard.
8) Only series 53
9) Depending on the installation position, L, L1 or L2 must be connected (please refer to installation instructions on pages 56, 57)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
1)
2)
Dimensions, size 28
DRG
EP.D. / EK.D.
8.82 (224)
5.51 (140)
4.86 (123.5)
4.21 (107)
2.48 (63)
29/60
2.48 (63)
5.12 (130)
4.49 (114)
RA-A 92703/12.11
L1
X
L
L2
L1
DFR / DFR1
EP.ED / EK.ED
9.45 (240)
L1
5.12 (130)
4.60 (117)
4.86 (123.5)
4.21 (107)
2.48 (63)
L2
S
L1
LA.D.
ED7. / ER7.
2.48 (63)
5.12 (130)
4.49 (114)
9.45 (240)
L1
5.12 (130)1)
9.09 (231)
5.51 (140)
S
L2
L1
ER7.: 6.26 inches (159 mm) if using an intermediate plate pressure controller.
For details of connection options and drive shafts, please refer to page 28
1)
30/60
RA-A 92703/12.11
L1
3.
07
0.56 (14.3)
3.03 (77)
(7
8)
(101.6 -0.054 )
7.44 (189)
max. 8.68 (220.5)
2.70 (68.5)
Flange
ISO 3019-1
DIA 4.000
3.998
45
5.18 (131.5)
0.37 (9.5)
0.25 (6.3)
5.75 (146)
6.77 (172)
Port plate 62
Detail Z
2.06 (52.4)
DIA 0.98 (25)
Port plate 64
1.03
(26.2)
30
1.0
(26 3 30
.2)
1.50 1.50
(38) (38)
View Y
B
1.50 1.50
(38) (38)
DIA 0.98
(25)
S
1.4
(35 1
.7)
1.41 (35.7)
2.
(52 06
.4)
7.01 (178)
8.31 (211)
2.7
5
DIA 1.50 (69
.9 )
38
View X
(101.6 -0.054 )
DIA 4.000
3.998
3.54 (90)
3.54 (90)
RA-A 92703/12.11
Dimensions, size 45
Drive shaft
Splined shaft 1 in
15T 16/32DP1)2) (SAE J744)
1/4-20UNC-2B3) 4)
1.49 (38)
0.63 (16)
0.20 (5)
0.63 (16)
Usable
shaft length
1.18
(30)
0.20 (5)
0.98 (25)
0.09
(2.2)
0.63
1.61 (41)
1.50 (38.1)
1.37 (34.9)
0.259 (6.35+0.25 )
0.250
(16)
1.81 (46)
0.12 (3)
0.56
(14.3) 0.75 1.18
(19) (30)
2.12(53.9)
2.43 (61.8)
0.251(6.35+0.025)
0.250
0.130 (3.2+0.1)
0.126
0.99(25.16)
Section A-B
0.251(6.35+0.025)
0.250
1.126
(28.6)
Taper
125:1000
ANSI B92.1a, 30 pressure angle, flat root, side fit, tolerance class 5
Splines according to ANSI B92.1a, run out of spline is a deviation from standard.
3) Thread according to ASME B1.1
4) For the maximum tightening torques the general instructions on page 60 must be observed.
5) Only series 52
1)
2)
0.63 (16)
0.20 (5)
0.99
(25.1)
0.63 (16)
0.13
(3.2)
0.16 (4)
1.30 (33.1)
1.61 (41)
1/4-20UNC-2B3)4)
Usable
shaft length
0.20 (5)
1.81 (45.9)
1.1102
DIA 1.0000
1.1024
0.9988
(28.2 -0.2) (25.4 - 0.03 )
1/4-20UNC-2B3) 4)
1.16
(29.5)
1.81
(45.9)
W
1/4-20UNC-2B3) 4)
DIA 0.98
(25)
Splined shaft 1 in
15T 16/32DP1) (SAE J744)
1/4-20UNC-2B3) 4)
31/60
32/60
Dimensions, size 45
RA-A 92703/12.11
Ports
Designation
Port for
Standard
Size1)
B
Port plate 61/62
Service line,
fixing thread
SAE J518
ASME B1.1
1 in
3/8-16UNC-2B; 0.71 (18) deep
4600 (315)
B; Port plate 64
Fixing thread
ISO 11926
4600 (315)
Suction line,
fixing thread
SAE J518
ASME B1.1
1 1/2 in
1/2-13UNC-2B; 0.87 (22) deep
75 (5)
S; Port plate 64
Fixing thread
ISO 11926
75 (5)
ISO 119263)
7/8-14UNF-2B; 13 deep
30 (2)
O5)
L1, L24)
ISO 119263)
7/8-14UNF-2B; 13 deep
30 (2)
X5)
Control pressure
ISO 119263)
4600 (315)
For the maximum tightening torques the general instructions on page 60 must be observed.
Depending on the application, momentary pressure spikes can occur. Consider this when selecting measuring equipment and
fittings.
3) The spot face can be deeper than as specified in the standard.
4) Only for series 53
5) Depending on the installation position, L, L1 or L2 must be connected (please refer to installation instructions on pages 56, 57)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
1)
2)
Dimensions, size 45
DRG
EP.D. / EK.D.
5.18 (131.5)
4.53 (115)
2.68 1.38
(68) (35)
L1
8.98 (228)
5.75 (146)
2.68 (68)
L1
33/60
5.22 (132.5)
4.57 (116)
RA-A 92703/12.11
X
S
S
L2
DFR / DFR1
EP.ED / EK.ED
9.68 (246)
X
X
S
ED7. / ER7.
9.84 (250)
2.68 (68)
5.24 (133)
4.57 (116.4)
L1
X
L1
5.20
(132)1)
9.25 (235)
5.75 (146)
L
L
S
L2
1)
L2
LA.D.
L1
5.24 (133)
4.68 (119)
5.18 (131.5)
4.53 (115)
2.68 (68)
ER7.: 6.57 inches (167 mm) if using an intermediate plate pressure controller.
34/60
Dimensions, size 60
RA-A 92703/12.11
L1
L
45
78
.5
DIA 5.0000
4.9975
0
(101.6 -0.054
)
Flange
ISO 3019-1
2.99 (78)
0.56 (14.3)
3.42 (87)
1.57 (40)
5.39 (137)
0.37
(9.5)
0.59 (15)
5.75 (146)
6.77 (172)
8.19 (208)
3.06 (77.8)
DIA 1.97
(50)
0.98 (25)
2.06
(52.4)
View X
S
1.67 (42.9)
1.30
Detail Z
(33)
2.06 (52.4)
0.98 (25)
View Y
DIA 5.0000
4.9975
0
(101.6 -0.054
)
Flange
ISO 3019-1
0.59 (15)
7.93 (201.5)
9.43 (239.5)
1.69
(42.9)
1.11 (26.2)
Dimensions of service line ports turned through 180 for counter-clockwise rotation
For details of connection options and drive shafts, please refer to page 38, 39
1)
0.37 (9.5)
0.25 (6.3)
1.03 (26.2)
1.81
(46)
Port plate 62
2.83 (72)
2.83 (72)
RA-A 92703/12.11
Dimensions, size 60
35/60
45
5.83 (148)
DIA 5.000
4.9975
0
(127 -0.063 )
0.59 (15)
.3
14
5.41 (137.4)
0.24 (6)
Flange
ISO 3019-1
(7
8.
5)
114.5
3.07 (78)
3.43 (87)
1.57 (40)
3.
09
0.50 (12.7)
4.51 (114.5)
5.75 (146)
8.19 (208)
View X
3.06 (77.8)
1.97 (50)
0.98 (25)
2.96 (52.4)
1.57
(40)
View Y
1.67
(42.9)
7.93 (201.5)
9.43 (239.5)
Dimensions of service line ports turned through 180 for counter-clockwise rotation
For details of connection options and drive shafts, please refer to page 38, 39
1)
1.11
(26.2)
DIA 5.000
4.9975
0
(127 -0.063 )
0.59 (15)
1.03 (26.2)
1.81
(46)
B
DIA 1.97 (50)
3.06 (77.8)
Flange
ISO 3019-1
Detail Z
0.50
(12.7)
2.06 (52.4)
DIA 0.98 (25)
Port plate 62
1.67 (42.9)
1.30
(33)
2.83 (72)
2.83 (72)
36/60
RA-A 92703/12.11
L1
L1
3.1
1
3.46 (88)
3.
05
(7
9)
43
(7
7.5
)
DIA 5.0000
4.9975
0
(101.6 -0.054 )
Flange
ISO 3019-1
14.3
3.50 (89)
5.53 (140.4)
4.37 (111)
45
L2
5.75 (146)
6.77 (172)
8.19 (208.2)
3.06 (77.8)
DIA 1.97
(50)
View X
2.06 (52.4)
DIA 0.98 (25)
Detail Z
1.54 (39)
DIA 1.97 50
3.06 (77.8)
DIA 5.0000
4.9975
0
(101.6 -0.054 )
0.37 (9.5)
0.25 (6.3)
Flange
ISO 3019-1
View Y
1.03
(26.2)
S
1.69
(42.9)
0.59 (15)
7.93 (201.5)
9.43 (239.5)
Dimensions of service line ports turned through 180 for counter-clockwise rotation
For details of connection options and drive shafts, please refer to page 38, 39
1)
1.03 (26.2)
Port plate 62
1.67 (42.9)
1.30 1.81
(33) (46)
RA-A 92703/12.11
37/60
L1
(7
9)
45
L2
0.59 (15)
5.75 (146)
3.46 (88)
3.50 (89)
3.
3.1
1
43
4
5
5
05
(7
7.5
5.51 (140)
4.37 (111)
0.
55
4.51 (114.5)
(14
)
L1
DIA 5.0000
4.9975
0
(127 -0.063
)
0.50 (12.7)
0.25 (6.3)
Flange
ISO 3019-1
4.51 (114.5)
5.75 (146)
5.91 (150)
8.19 (208)
3.06 (77.8)
DIA 1.97 (50)
View X
S
1.67
1.81
(42.9)
1.30 (46)
(33)
2.06 (52.4)
DIA 0.98 (25)
Port plate 62
max. 8.68 (220.5)
4.55 (115.5)
0.50 (12.7) 1.54 (39)
0.25 (6.3)
L1
Flange
ISO 3019-1
1.03
(26.2)
Detail Z
View Y
1.03
(26.2)
DIA 5.0000
4.9975
0
(127 -0.063
)
S
1.69
(42.9)
0.59 (15)
7.93 (201.5)
9.43 (239.5)
Dimensions of service line ports turned through 180 for counter-clockwise rotation
For details of connection options and drive shafts, please refer to page 38, 39
1)
2.83 (72)
2.83 (72)
38/60
Dimensions, size 60 / 63
RA-A 92703/12.11
Drive shaft
Splined shaft 1 1/4 in
14T 12/24DP1)2) (SAE J744)
5/16-18UNC-2B3) 4)
1.87 (47.5)
0.75 (19)
0.20 (5)
0.20 (5)
1.50 (38)
Usable
shaft length
1.14
(29)
0.75
DIA 1.37
(34.91)
0.20 (5)
1.87 (47.5)
1.63 (41.3)
5/16-18UNC-2B3)4)
1.3898
DIA 1.2500
1.3819
1.2488
(35.3 -0.2) (31.75 - 0.03 )
1/4-20UNC-2B3) 4)
0.63 (16)
0.12
(3)
(19)
1.81 (45.9)
2.18 (55.4)
0.1394(3.540.1)
0.1354
0.12
(3)
1.18
(30)
0.93
1.37
(23.6) (34.9)
2.61 (66.4)
0.3136(7.94+0.025)
0.3126
DIA 1.25
(31.75)
0.56
(14.1)
Section A-B
1.16
(28.6)
0.3136(7.94+0.025)
0.3126
0.99
(25.16)
0.13
(3.2)
0.16 (4)
Taper
125:1000
ANSI B92.1a, 30 pressure angle, flat root, side fit, tolerance class 5
Splines according to ANSI B92.1a, run out of spline is a deviation from standard.
3) Thread according to ASME B1.1
4) For the maximum tightening torques the general instructions on page 60 must be observed.
5) Only series 52
1)
2)
0.63 (16)
0.20 (5)
1.81
(45.9)
Splined shaft 1 in
15 T 16/32DP1)2) (SAE J744)
1.30 (33.1)
0.98
(25)
2.18 (55.4)
2.18
(55.4)
W
Splined shaft 1 in
15T 16/32DP1) (SAE J744)
0.75 (19)
Usable
shaft length
1.56
(39.5)
1/4-20UNC-2B3) 4)
RA-A 92703/12.11
Dimensions, size 60 / 63
39/60
Ports
Designation
Port for
Standard
Size1)
Service line,
fixing thread
SAE J518
ASME B1.1
1 in
3/8-16UNC-2B; 0.71 (18) deep
4600 (315)
Suction line,
fixing thread
SAE J518
ASME B1.1
2 in
1/2-13UNC-2B; 0.87 (22) deep
75 (5)
ISO 119263)
30 (2)
O5)
L1, L24)
ISO 119263)
30 (2)
X5)
Control pressure
ISO
119263)
For the maximum tightening torques the general instructions on page 60 must be observed.
Depending on the application, momentary pressure spikes can occur. Consider this when selecting measuring equipment and
fittings.
3) The spot face can be deeper than as specified in the standard.
4) Only for series 53
5) Depending on the installation position, L, L1 or L2 must be connected (please refer to installation instructions on pages 56, 57)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
1)
2)
Dimensions, size 60 / 63
DRG
EP.D. / EK.D.
9.49 (241)
5.94 (151)
4.55 (115.5)
X 2.56 (65)
L1
5.39 (137)
4.76 (121)
L1
L2
1.42
3.23 (82)(36)
L1
9.86 (250.5)
4.55 (115.5)
X 2.56 (65)
L1
5.39 (137)
4.76 (121)
L1
EP.ED / EK.ED
2.55 1.40
X (64.8)(35.6)
L1
5.53 (140.4)
4.92 (125)
4.88 (123.9)
RA-A 92703/12.11
5.53 (140.4)
4.92 (125)
40/60
S
L2
LA.D.
ED7. / ER7.
5.51 (140)
5.04 (128)
4.88 (124)
1)
9.88 (251)
2.56 (65)
L1
L1
L
L1
L2
ER7.: 6.77 inches (172 mm) if using an intermediate plate pressure controller.
5.391)
(137)1)
9.72 (247)
5.91 (150)
RA-A 92703/12.11
41/60
45
95
DIA 5.0000
4.9975
0
(127 -0.063
)
6.14 (156)
Flange
ISO 3019-1
3.68 (93.5)
0.50 (12.7)
L1
0.69 (17.5)
3.42 (87)
0.79 (20)
7.13 (181)
8.26 (210)
9.65 (245)
View X
2.63
(66.7)
3.50 (88.9)
DIA 2.36 (60)
1.57 (40)
DIA 5.0000
4.9975
0
(127 -0.063
)
Flange
ISO 3019-1
1.25 (31.8)
View Y
B
1.25
(31.8)
0.50 (12.7)
2.63 (66.7)
DIA 1.26 (32)
Port plate 62
2.00 (50.8)
1.97 1.77
(50) (45)
Detail Z
S
0.79 (20)
9.27 (235.5)
10.90 (277)
2.00 (50.8)
Dimensions of service line ports turned through 180 for counter-clockwise rotation
For details of connection options and drive shafts, please refer to page 43
1)
3.74 (95)
3.35 (85)
42/60
RA-A 92703/12.11
L1
5.91 (150)
4.96 (126)
5)
45
3.
74
(9
(9
5)
(127 -0.063 )
)
(4
DIA
6
0.1
5.0000
4.9975
Flange
ISO 3019-1
6
0.1
45
(4
L2
5.12 (130)
9.65 (245)
4.51 (114.5)
5.75 (146)
2.63
(66.7)
3.50 (88.9)
DIA 2.36 (60)
View X
View Y
(127 -0.063 )
DIA
5.0000
4.9975
Flange
ISO 3019-1
Detail Z
0.79 (20)
5.12 (130)
9.25 (235)
10.91 (277)
2.00
(50.8)
1.25
(31.8)
Dimensions of service line ports turned through 180 for counter-clockwise rotation
For details of connection options and drive shafts, please refer to page 43
1)
1.25 (31.8)
Port plate 62
2.00 (50.8)
1.97 1.77
(50) (45)
2.63 (66.7)
DIA 1.26 (32)
0.50 (12.7)
0
(14 .56
.3
4.51 (114.5)
)
4.04 (102.5) 3.98 (101)
1.42 (36)
3.
74
0.50 (12.7)
3.74 (95)
3.35 (85)
RA-A 92703/12.11
Dimensions, size 85
43/60
Drive shaft
U
2.12 (54)
1.10 (28)
0.20 (5)
1.87 (47.5)
0.75 (19)
0.20 (5)
1.38
(35)
1.71
(43.5)
Usable
shaft length
0.20 (5)
1.30 (33)
2.18 (55.4)
2.18
(55.4)
2.44
(61.9)
0.75 (19)
Ports
Designation
Port for
Standard
Size4)
Service line,
fixing thread
SAE J518
ASME B1.1
1 1/4 in
1/2-13UNC-2B; 0.75 (19) deep
4600 (315)
Suction line,
fixing thread
SAE J518
ASME B1.1
2 1/2 in
1/2-13UNC-2B; 1.07 (27) deep
75 (5)
ISO 119266)
30 (2)
O8)
L1, L27)
ISO 119266)
30 (2)
X8)
119266)
4600 (315)
Control pressure
ISO
ANSI B92.1a, 30 pressure angle, flat root, side fit, tolerance class 5
Splines according to ANSI B92.1a, run out of spline is a deviation from standard
3) Thread according to ASME B1.1
4) For the maximum tightening torques the general instructions on page 60 must be observed.
5) Depending on the application, momentary pressure spikes can occur. Consider this when selecting measuring equipment and
fittings.
6) The spot face can be deeper than as specified in the standard.
7) Only for series 53
8) Depending on the installation position, L, L1 or L2 must be connected (please refer to installation instructions on pages 56, 57)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
1)
2)
EP.D. / EK.D.
6.14 (156)
5.49 (139.5)
10.51 (267)
7.15 (181.5)
L1
DFR / DFR1
6.14 (156)
5.49 (139.5)
11.06 (281)
7.15 (181.5)
L1
L
LA.D.
10.67 (271)
7.15 (181.5)
1)
L2
10.68 (271.4)
X 2.91 (74)
5.90 (149.9)
5.71 (145)
5.25 (133.4)
L1
ED../ ER..
X 2.91 (74)
L2
X 2.91 (74)
EP.ED / EK.ED
X 2.91 (74)
5.91 (150)
5.24 (133)
RA-A 92703/12.11
L1
L
L2
L1
2.17 (55)
0.76 (19.4)
6.14 (156)1)
44/60
EP.D. / EK.D.
10.51 (267)
7.15 (181.5)
X 2.91 (74)
L1
5.91 (150)
5.24 (133)
4.96 (126)
L2
LA.D.
11.06 (281)
L1
L2
L2
2.91 (74)
5.91 (150)
5.71 (145)
5.24 (133)
EP.ED / EK.ED
10.75 (273)
7.15 (181.5)
45/60
5.91 (150)
5.59 (142)
RA-A 92703/12.11
L1
L
L2
46/60
RA-A 92703/12.11
L1
X
45
5)
5)
0.69 (17.5)
4.03 (102.5)
4
3.7
(9
(9
45
6
0.1
L2
(4
5.12 (130)
9.65 (245)
7.13 (181)
8.27 (210)
2.62
(66.7)
3.50 (88.9)
DIA 2.36 (60)
View X
Detail Z
View Y
(127 -0.063 )
DIA 5.0000
4.9975
Flange
3019-1
5.12 (130)
9.25 (235)
10.91 (277)
2.00
(50.8)
1.25
(31.8)
Dimensions of service line ports turned through 180 for counter-clockwise rotation
For details of connection options and drive shafts, please refer to page 49
1)
1.25 (31.8)
Port plate 62
2.00 (50.8)
1.97 1.77
(50) (45)
0.79 (20)
3.98 (101)
5.91 (150)
(127 -0.063 )
)
(4
DIA 5.0000
4.9975
6
0.1
Flange
3019-1
3.
74
0.50 (12.7)
RA-A 92703/12.11
L1
5.91 (150)
4.96 (126)
5)
6
0.1
45
56
(14
.
(4
0.
L2
5.12 (130)
9.65 (245)
4.51 (114.5)
5.75 (146)
2.62
(66.7)
3.50 (88.9)
DIA 2.36 (60)
View X
0
-0.063 )
0.79 (20)
5.12 (130)
9.25 (235)
10.91 (277)
2.00
(50.8)
1.97
(50)
Detail Z
1.77
(45)
1.25
(31.8)
Dimensions of service line ports turned through 180 for counter-clockwise rotation
For details of connection options and drive shafts, please refer to page 49
1)
1.25 (31.8)
View Y
(127
DIA
5.0000
4.9975
Flange
3019-1
2.00 (50.8)
Port plate 62
2.63 (66.7)
DIA 1.26 (32)
0.50 (12.7)
3)
4.51 (114.5)
4.03 (102.5) 3.98 (101)
4
3.7
(9
5)
0
-0.063 )
45
(127
)
(4
DIA
6
0.1
5.0000
4.9975
Flange
3019-1
(9
1.42 (36)
3.
74
0.50.(12.7)
47/60
3.74 (95)
3.35 (85)
ED../ ER..
10.71 (272)
X 2.91 (74)
L1
5.91 (150)
5.24 (133)
L1
L
DRF/DRS
X 2.91 (74)
L1
5.91 (150)
5.24 (133)
L2
LA.D.
10.67 (271)
7.15 (181.5)
X 2.91 (74)
5.90 (149.9)
5.71 (145)
5.25 (133.4)
1)
L2
RA-A 92703/12.11
6.14 (156)1)
48/60
L1
L
L2
ER7.: 7.52 inches (191 mm) if using an intermediate plate pressure controller.
L2
RA-A 92703/12.11
49/60
2.12 (54)
1.10 (28)
0.20 (5)
1.87 (47.5)
0.75 (19)
0.20 (5)
1.38
(35)
1.71
(43.5)
0.75 (19)
0.20 (5)
Usable
shaft length
2.18 (55.4)
2.18
(55.4)
2.44
(61.9)
1.30 (33)
Ports
Designation
Port for
Standard
Size4)
Maximum
pressure
[bar]5)
State
Service line,
fixing thread
SAE J518
ASME B1.1
1 1/4 in
1/2-13UNC-2B; 0.75 (19) deep
4600 (315)
Suction line,
fixing thread
SAE J518
ASME B1.1
2 1/2 in
1/2-13UNC-2B; 1.07 (27) deep
75 (5)
ISO 119266)
O8)
L1, L2
ISO
119266)
X8)
Control pressure
ISO 119266)
ANSI B92.1a, 30 pressure angle, flat root, side fit, tolerance class 5
2) Splines according to ANSI B92.1a, run out of spline is a deviation from standard.
3) Thread according to ASME B1.1
4) For the maximum tightening torques the general instructions on page 60 must be observed.
5) Depending on the application, momentary pressure spikes can occur. Consider this when selecting measuring equipment and
fittings.
6) Metric fixing thread is a deviation from standard.
7) The spot face can be deeper than as specified in the standard.
8) Depending on the installation position, L, L1 or L2 must be connected (please refer to installation instructions on pages 56, 57)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
1)
50/60
Cut A - B
A3
A2
DIA 3.2520
3.2508
(82.55 +0.050
+0.020 )
45
B
4.19
(106
.5)
A4
0.39
(10)
to mounting flange A1
A3
)
(82.55
+0.050
+0.020
DIA 3.2520
3.2508
4.1
10 9
6.5
A5
to mounting flange
0.39
(10)
A2
A1
A2
A3
18
7.17
(182)
0.37
(9.3)
1.70
M10 x 1.5,
(43.3) 0.57 (14.5) deep
28
8.03
(204)
0.39
(9.9)
1.85
(47)
M10 x 1.5,
0.63 (16) deep
45
9.02
(229)
0.42
(10.7)
2.09
(53)
M10 x 1.5,
0.63 (16) deep
60/ 10.03
63 (255)
0.37
(9.5)
2.32
(59)
M10 x 1.5,
0.63 (16) deep
85
11.89
(302)
0.53
(13.4)
2.68
(68)
M10 x 1.5,
0.79 (20) deep
100 11.89
(302)
0.53
(13.4)
2.68
(68)
M10 x 1.5,
0.79 (20) deep
A4
A3
5.7
(14 5
6)
4.0020
DIA 4.0008
+0.050
(101.6 +0.020 )
45
A5
A2
NG
A1
18
7.17
(182)
28
8.03 1.54
0.74
(204) (39.3) (18.8)
1.85
(47)
M10 x 1.5,
0.63 (16) deep
45
9.02 1.55
0.75
(229) (39.4) (18.9)
2.09
(53)
M10 x 1.5,
0.63 (16) deep
60/
63
10.03 1.55
0.75
(255) (39.4) (18.9)
2.40
(61)
M10 x 1.5,
0.63 (16) deep
85
11.89 1.74
(302) (44.1)
0.93
2.56
(23.6) (65)
M10 x 1.5,
0.79 (20) deep
0.93
2.56
(23.6) (65)
M10 x 1.5,
0.79 (20) deep
A3
A4
0.37
(9.3)
1.70
M10 x 1.5,
(43.3) 0.57 (14.5) deep
Cut A - B
A42)
A1
45
NG
Cut A - B
RA-A 92703/12.11
A2
to mounting flange A1
NG
A1
A2
A3
A4
A52)
28
8.03
(204)
1.66
(42.3)
0.70
(17.8)
1.85
(47)
M12 x 1.75,
0.71 (18) deep
45
9.02
(229)
1.67
(42.4)
0.71
(17.9)
2.09
(53)
M12 x 1.75,
0.71 (18) deep
60/ 10.03
63 (255)
1.67
(42.4)
0.71
(17.9)
2.32
(59)
M12 x 1.75,
0.71 (18) deep
85
11.89
(302)
1.83
(46.5)
0.87
(22)
2.72
(69)
M12 x 1.75,
0.79 (20) deep
100 11.89
(302)
1.83
(46.5)
0.87
(22)
2.72
(69)
M12 x 1.75,
0.79 (20) deep
0.39
(10)
RA-A 92703/12.11
A4
A3
45
51/60
DIA 4.0020
4.0008
(101.6 +0.050
+0.020 )
B
5.7
(14 5
6)
A52)
NG
A1
45
2.10
M12 x 1.75,
(53.4) 0.71 (18) deep
2.32
M12 x 1.75,
(58.9) 0.71 (18) deep
85
A2
M12 x 1.75,
0.79 (20) deep
M12 x 1.75,
0.79 (20) deep
A5
0.39
(10)
A2
A1
A2
A3
A42)
0.31
(8)
2.32
(59)
M12 x 1.75,
0.63 (16) deep
11.87
0.51
(301.5) (13)
2.67
(67.9)
M12 x 1.75,
through
100 11.87
0.51
(301.5) (13)
2.67
(67.9)
M12 x 1.75,
through
NG
Cut A - B
A4
60/ 10.03
63 (255)
A3
+0.050
114.5
127 +0.020
85
114.5
A5
13
to mounting flange A1
4.51 (114.5)
4.51 (114.5)
A5
A3
A1
A2
A3
A42)
85
11.87
(301.5)
0.51
(13)
2.67
(67.9)
M12 x 1.75,
through
100 11.87
(301.5)
0.51
(13)
2.67
(67.9)
M12 x 1.75,
through
DIA 5.0020
5.0008
(127 +0.050
+0.020 )
A4
A1
0.53
52/60
Cut A - B
A
45
RA-A 92703/12.11
A4
NG
A1
A2
85
11.87
(301.5)
0.51 2.67
(13) (67.9)
M12 x 1.75,
through
100 11.87
(301.5)
0.51 2.67
(13) (67.9)
M12 x 1.75,
through
A3
A42)
(127 +0.050
+0.020 )
A5
A3
DIA 5.0020
5.0008
7.13 )
81
(1
A5
B
to mounting flange
0.51
(13)
A2
A1
A2
A3
A42)
85
11.89
(302)
0.31
(8)
2.68
(68)
M16 x 2,
0.94 (24) deep
100 11.89
(302)
0.31
(8)
2.68
(68)
M16 x 2,
0.94 (24) deep
+0.050
7.13
1)
(18
A1
(127 +0.020 )
A4
A3
NG
5.0020
DIA 5.0008
A5
B
to mounting flange A1
1)
2)
0.51
(13)
RA-A 92703/12.11
53/60
5/8 in
K01
10 (U)
18 (U)
F (5 to 22)
Through
drive
available for
NG
18 to 100
3/4 in
K52
18 (S, R)
18 to 100
K68
10 (S)
18 (U)
18 (S, R)
28 (S, R)
45 (U, W)1)
45 (S, R)
60, 63 (U, W) 2)
60, 63 (S, R)
28 (S, R)
45 (U, W)
45 (S, R)
28 to 100
45 to 100
63 to 100
85 (S)
100 (S)
85 (U, W)
100 (U, W)
85 (S)
100 (S)
85 to 100
71 (S, R)
85 to 100
85 to 100
82-2 (A)
1 in
K04
K15
1 1/2 in
K16
K07
1 1/2 in
K24
1)
2)
A10V(S)O/5x
NG (shaft)
A10VO/31
NG (shaft)
Gear pump
design (NG)
54/60
RA-A 92703/12.11
When using combination pumps it is possible to have multiple, mutually independent circuits without the need for a splitter
gearbox.
When ordering combination pumps the model codes for the first and the second pump must be joined by a "+".
Order example:
A10VO85DRS/53R-VSC12K04+
A10VO45DRF/53R-VSC11N00
The tandem pump comprising two identical sizes is permissible without additional supports taking into account a maximum
dynamic mass acceleration of 10 g (= 98.1 m/s2).
For combination pumps comprising more than two pumps, the mounting flange must be calculated for the permissible moment of
inertia.
Permissible moment of inertia
NG
10
18
28
45
60/63
85
100
Tm
lb-ft
(Nm)
656
(890)
664
(900)
1010
(1370)
2270
(3080)
2270
(3080)
lb-ft
(Nm)
65
(89)
66
(90)
101
(137)
227
(308)
227
(308)
18
(8)
25
(11.5)
37.5
(17)
31
(14)
53
(24)
40
(18)
62
(28)
48.5
(22)
99
(45)
75
(34)
99
(45)
75
(34)
3.23
(82)
3.19
(81)
3.74
(95)
3.94
(100)
4.80
(122)
4.80
(122)
m1 lbs
(kg)
m lbs
(kg)
l1
A10VO
(1st pump)
l1
m1
in
(mm)
A10VO
m2
(2nd pump)
l2
m1, m2, m3
Mass of pumps
[lbs (kg)]
l1, l2, l3
Distance center
of gravity
[in (mm)]
Tm = (m1 l1 + m2 l2 + m3 l3)
1
12 (102) [lb-ft (Nm)]
RA-A 92703/12.11
55/60
Circuit symbol
Mating connector
DEUTSCH DT06-2S-EP04
Bosch Rexroth Mat. No. R902601804
Consisting of:
DT designation
1 case _ _______________________________DT06-2S-EP04
1 wedge ________________________________________W2S
2 sockets _____________________________ 0462-201-16141
The mating connector is not included in the delivery contents.
This can be supplied by Bosch Rexroth on request.
1.44 (36.7)
(1)
DIA 1.46
(37)
1.44 (36.7)
(2)
1.97 (50)
2.70 (68.5)
Electronic controls
Control
Electronics function
Electronics
RA
RC2-2/21
1)
2)
1)
Further information
analog
RE 95230
Digital
RE 95201
56/60
RA-A 92703/12.11
Installation instructions
General
The axial piston unit must be filled with hydraulic fluid and air
bled during commissioning and operation. This must also be
observed following a longer standstill as the axial piston unit
empty via the hydraulic lines.
Below-reservoir installation means the axial piston unit is installed outside of the reservoir below the minimum fluid level.
2
amin
ht min
h min
The case drain fluid in the case interior must be directed to the
reservoir via the highest case drain port (L1, L2, L3).
For combinations of multiple units, make sure that the respective case pressure in each unit is not exceeded. In the event of
pressure differences at the drain ports of the units, the shared
drain line must be changed so that the minimum permissible
case pressure of all connected units is not exceeded in any
situation. If this is not possible, separate drain lines must be
laid if necessary.
SB
SB
ht min
h min
L1
L1 L
S
X
4
amin
amin
In all operating conditions, the suction line and case drain line
must flow into the reservoir below the minimum fluid level. The
permissible suction height hS is a result of the overall pressure
loss, but may not be greater than hS max = 31.50 in (800 mm).
The minimum suction pressure at port S must also not fall
below 12 psi (0.8bar) absolute during operation.
ht min
h min
L2
SB
ht min
h min
L1
L1
Installation
position
Air bleed
Filling
S+L
L1
S + L1
31)
L2
S + L2
S+L
1)
Only series 53
SB
Installation position
amin
RA-A 92703/12.11
57/60
Installation instructions
Above-reservoir installation
Inside-reservoir installation
To prevent the axial piston unit from draining, a height difference hES min of at least 0.98 in (25 mm) is required in installation position 6.
L1 L
L1
L1
SB
hES min
amin
ht min
LSB
ht min
10
amin
L1
h min
h min
L
X
ht min
h min
11
hs max
hs max
ht min
h min
SB
L2
SB
amin
L1
SB
L1
h min
L1
ht min
SB
S
L
L1
hs max
hs max
ht min
h min
SB
amin
SB
Installation
position
Air bleed
Filling
L1
L, L1
10
L1
L, L1
111)
L2
12
S+L
amin
Installation
position
Air bleed
L, L1 (F)
L1 (F)
71)
S + L2 (F)
S + L (F)
Filling
Suction port
L, L1
SB
ht min
hmin
hES min
1)
ht min
ht min
h min
amin
amin
8
L2
12
amin
Only series 53
hS max
amin
h min
58/60
Notes
RA-A 92703/12.11
RA-A 92703/12.11
Notes
59/60
60/60
RA-A 92703/12.11
General instructions
The A10VO pump is designed to be used in open circuit.
Project planning, installation and commissioning of the axial piston unit require the involvement of qualified personnel.
Before operating the axial piston unit, please read the appropriate instruction manual thoroughly and completely. If necessary,
request these from Bosch Rexroth.
During and shortly after operation, there is a risk of burns on the axial piston unit and especially on the solenoids.
Take appropriate safety measures (e.g. by wearing protective clothing).
Depending on the operating conditions of the axial piston unit (operating pressure, fluid temperature), the characteristics may
shift.
Service line ports:
-- The ports and fixing threads are designed for the specified maximum pressure. The machine or system manufacturer must ensure that the connecting elements and lines correspond to the specified application conditions (pressure, flow, hydraulic fluid,
temperature) with the necessary safety factors.
-- The service line ports and function ports are only designed to accommodate hydraulic lines.
Pressure cut-off and pressure control do not provide security against pressure overload. A separate pressure relief valve
is to be provided in the hydraulic system.
The data and notes contained herein must be adhered to.
The product is not approved as a component for the safety concept of a general machine according to DIN EN ISO 13849.
The following tightening torques apply:
-- Fittings:
Observe the manufacturer's instruction regarding the tightening torques of the used fittings.
-- Fixing screws:
For fixing screws with metric ISO thread according to DIN13 or thread according to ASME B1.1, we recommend checking the
tightening torque individually according to VDI 2230.
-- Female threads in axial piston unit:
The maximum permissible tightening torques MG max are maximum values for the female threads and must not be exceeded.
For values, see the following table.
-- Threaded plugs:
For the metal threaded plugs supplied with the axial piston unit, the required tightening torques of the threaded plugs MV
apply. For values, see the following table.
Ports
Standard
ISO 11926
Maximum permissible
tightening torque for
female threads MG max
Thread size
Required
tightening torque for
threaded plugs MV
Size of
hexagon socket of
threaded plugs
7/16-20UNF-2B 40 Nm
18 Nm
3/16 in
9/16-18UNF-2B
35 Nm
1/4 in
80 Nm
3/4-16UNF-2B
160 Nm
70 Nm
5/16 in
7/8-14UNF-2B
240 Nm
110 Nm
3/8 in
1 1/16-12UN-2B 360 Nm
170 Nm
9/16 in