Sei sulla pagina 1di 8

Skip directly to the section that covers your version of Windows (XP and earlier, Vista or Windows 7)

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)


Here are step-by-step instructions to get you going quickly. Later, as you wish to learn more about using TrueRTA, you can refer
to the built-in Users Guide under the Help menu.

1) Install the TrueRTA software.


Double-click on the file "TrueRTA_setup.exe" to start the installation process. (Alternately, insert the
TrueRTA CD into your PCs drive and allow the file named "TrueRTA_setup.exe" to auto-play.)
Follow the on-screen instructions to complete the software installation.
2) Configure the Sound System Hardware and Provide an Input Signal.
PC sound systems vary greatly so it is up to the user to configure their specific hardware. For testing
purposes simpler is usually better. We will address a basic USB audio interface made by Behringer
and widely available at music stores for under $30. This is the Behringer UCA202 which provides
stereo line-in and line-out on RCA connectors. TrueRTA is initially coarsely calibrated for the
UCA202 USB audio interface shown below.

With your sound system connected to the PC you now need to provide an input signal at the audio
interface unit for testing purposes. This could be the output of a microphone mixer with microphone
connected or the output from a CD or other media player. You can also patch the line-out directly to
the line-in to establish a self-test configuration.
3) Launch the TrueRTA application software.
From the Windows Start button select All Programs then select TrueRTA. If you have
purchased an upgrade to a higher level of performance then this is the time to enter your registration
information as detailed in your registration e-mail.
4) Start the Analyzer and look for the Test Signal.
Start the analyzer running either by clicking on the GO button on the toolbar or by pressing
Alt+Space at the keyboard. The analyzer will start running, various commands will be disabled and
the spectrum of the current input signal will be displayed. Try using the controls in the Analyzer tool
bar at the right to widen the upper and lower dB limits to +20 dBu at the top and -160 dBu at the
bottom. This will insure that the full input range is displayed and that the input signal is not hidden off
screen. The spectrum you see will depend on the test signal you have provided. If you have a mic
connected then you should be able to speak into the mic and see your voice spectrum appear on the
display as the analyzer runs. If you have a CD or other music source connected then you should see
the changing spectrum of the music as it plays. If your hardware is configured for self test you can
expect to see the system noise floor wiggling about until you start the generator to provide a test
signal. Stop the analyzer either by pressing Stop at the toolbar or by pressing Alt+Space again at
the keyboard. Those functions that were disabled while the analyzer was running will become enabled
again once the analyzer is stopped.
If you have a microphone connected for input, then sing a note and stop the analyzer (Alt + Space) to
freeze the display. You should see multiple peaks on the screen. If you happened to sing (or play) an
A the left most frequency peak might be 220 Hz. This is the fundamental tone of the complex
waveform that constitutes the note. The 2nd harmonic would be 440 Hz; the 3rd harmonic would be 3
times the fundamental, or 660 Hz, and so on.
Revised: 21May10

TrueRTA 3.5 Setup for Windows XP, page 2

If you are in self-test mode then you can examine the generator output directly. At the left side of the
screen is the Generator dialog bar. Enter 200 in the Freq. field, select Sine in the Wave section and
set the Amplitude to 0 dBu. Press the On/Off button once to start the generator. You may not hear the
200 Hz wave depending on how your system is configured. With the generator running you should see
a spike at 200 Hz. Stop and start the generator and the spike should disappear and reappear.
Momentarily disconnect the self test patch cable to verify that the signal is actually passing through
the test loop (and not being seen via some other internal computer pathway). The signal should vanish
when you break the connection and appear again after the connection is reestablished.
Stop the analyzer and switch to Oscilloscope mode (at either the toolbar or the Oscilloscope menu).
Start the oscilloscope running to see the test signal in real time. Notice that the dialog bar at the right
has changed to show you customary Oscilloscope controls. Use Stop to freeze the display.
5) After taking a spectrum measurement you can:

Save the workbench data to one of 20 project memories.


Manipulate the data (shift, average, smooth, sum or difference) using the utilities functions.
Save a TrueRTA project file (file type .rta) which includes all 20 memories.
Export the measured data in.txt format.
Overlay plots of various measured responses from the 20 memories for detailed comparison.
Print a report showing the displayed memories along with their notes.

6) Quit TrueRTA.
Quit the TrueRTA application software by pressing Ctrl+Q at the keyboard or by selecting Exit
under the File menu. On exit the software saves your application settings for the next session.
7) Future sessions with TrueRTA.
In the future when you want to use TrueRTA you only need to connect an audio hardware unit and
then launch the TrueRTA software. If you happen to launch the software first then select Audio
Device Selection under the Audio I/O menu so that TrueRTA can re-scan for new audio
hardware.
Troubleshooting
If there is a problem seeing the input signal, open the Windows Sound Control Panel and select the
Audio tab. Then select the Sound Playback Default device USB Audio CODEC (the Behringer unit)
as shown below at the left. Click on Volume to open the mixer shown below at the right. Make
sure the Speaker and Wave volumes are set to maximum and that the corresponding balance
controls are set to center. In general, for most audio devices under Windows XP, both record and
playback levels should be set at maximum.

Revised: 21May10

Quick Start for TrueRTA (v3.5) on Windows Vista


Here are step-by-step instructions to get you going quickly. Later, as you wish to learn more about using TrueRTA, you can refer
to the built-in Users Guide under the Help menu.

1) Install the TrueRTA software.


Double-click on the file "TrueRTA_setup.exe" to start the installation process. (Alternately, insert the
TrueRTA CD into your PCs drive and allow the file named "TrueRTA_setup.exe" to auto-play.)
Follow the on-screen instructions to complete the software installation.
2) Configure the Sound System Hardware for Windows Vista.
PC sound systems vary greatly so it is up to the user to configure their specific hardware. For testing
purposes simpler is usually better. We will address a basic USB audio interface made by Behringer
and widely available at music stores for under $30. This is the Behringer UCA202 which provides
stereo line-in and line-out on RCA connectors. TrueRTA is initially coarsely calibrated for the
UCA202 USB audio interface shown below.

From the Windows Start button select Control Panel/Sound. Once the Sound control panel opens
select the Recording tab as seen below (left). Next, double-click on the device USB Audio
CODEC to open the Properties window seen below (right).

Select the Levels tab and verify that the level is set to 25 as seen below (left). Next, switch to the
Advanced tab and select 2 channel, 16 bit, 44100 Hz (CD Quality) as seen below (right).
This step is critical as TrueRTA will not operate with the default audio setting of 1 channel input.

Revised: 21May10

TrueRTA 3.5 Setup for Windows Vista, page 2

Click the OK button once to close the Properties window and then click OK again to close the
Sound control panel. Disconnect the USB unit from the first USB port and repeat this setup sequence
for each USB port on your PC that you wish to be setup for use with TrueRTA. You should only need
to do this one time as each USB port remembers its own settings separately from the other ports.
3) Raise the Windows volume control to maximum.
From the task bar, raise the Windows volume control to maximum.
4) Provide a Test Signal.
With your sound system connected to the PC and configured for Windows Vista you now need to
provide an input signal at the audio interface unit for testing purposes. This could be the output of a
microphone mixer with a microphone connected or the output from a CD or other media player. You
can also patch the line-out directly to the line-in to establish a self-test configuration.
5) Launch the TrueRTA application software.
From the Windows Start button select All Programs then select TrueRTA. If you have
purchased an upgrade to a higher level of performance then this is the time to enter your registration
information as detailed in your registration e-mail.
6) Start the Analyzer and look for the Test Signal.
Start the analyzer running either by clicking on the GO button on the toolbar or by pressing
Alt+Space at the keyboard. The analyzer will start running, various commands will be disabled and
the spectrum of the current input signal will be displayed. Try using the controls in the Analyzer tool
bar at the right to widen the upper and lower dB limits to +20 dBu at the top and -160 dBu at the
bottom. This will insure that the full input range is displayed and that the input signal is not hidden off
screen. The spectrum you see will depend on the test signal you have provided. If you have a mic
connected then you should be able to speak into the mic and see your voice spectrum appear on the
display as the analyzer runs. If you have a CD or other music source connected then you should see
the changing spectrum of the music as it plays. If your hardware is configured for self test you can
expect to see the system noise floor wiggling about until you start the generator to provide a test
signal. Stop the analyzer either by pressing Stop at the toolbar or by pressing Alt+Space again at
the keyboard. Those functions that were disabled while the analyzer was running will become enabled
again once the analyzer is stopped.
Revised: 21May10

TrueRTA 3.5 Setup for Windows Vista, page 3

If you have a microphone connected for input, then sing a note and stop the analyzer (Alt + Space) to
freeze the display. You should see multiple peaks on the screen. If you happened to sing (or play) an
A the left most frequency peak might be 220 Hz. This is the fundamental tone of the complex
waveform that constitutes the note. The 2nd harmonic would be 440 Hz; the 3rd harmonic would be 3
times the fundamental, or 660 Hz, and so on.
If you are in self-test mode then you can examine the generator output directly. At the left side of the
screen is the Generator dialog bar. Enter 200 in the Freq. field, select Sine in the Wave section and
set the Amplitude to 0 dBu. Press the On/Off button once to start the generator. You may not hear the
200 Hz wave depending on how your system is configured. With the generator running you should see
a spike at 200 Hz. Stop and start the generator and the spike should disappear and reappear.
Momentarily disconnect the self test patch cable to verify that the signal is actually passing through
the test loop (and not being seen via some other internal computer pathway). The signal should vanish
when you break the connection and appear again after the connection is reestablished.
Stop the analyzer and switch to Oscilloscope mode (at either the toolbar or the Oscilloscope menu).
Start the oscilloscope running to see the test signal in real time. Notice that the dialog bar at the right
has changed to show you customary Oscilloscope controls. Use Stop to freeze the display.
7) After taking a spectrum measurement you can:

Save the workbench data to one of 20 project memories.


Manipulate the data (shift, average, smooth, sum or difference) using the utilities functions.
Save a TrueRTA project file (file type .rta) which includes all 20 memories.
Export the measured data in.txt format.
Overlay plots of various measured responses from the 20 memories for detailed comparison.
Print a report showing the displayed memories along with their notes.

8) Quit TrueRTA.
Quit the TrueRTA application software by pressing Ctrl+Q at the keyboard or by selecting Exit
under the File menu. On exit the software saves your application settings for the next session.
9) Future sessions with TrueRTA.
In the future when you want to use TrueRTA you only need to connect an audio hardware unit and
then launch the TrueRTA software. If you happen to launch the software first then select Audio
Device Selection under the Audio I/O menu so that TrueRTA can re-scan for new audio
hardware.
Troubleshooting
If there is a problem, review the USB port setup in Step 2. If you are using an audio interface other
than the UCA202 open the Audio Device Selection dialog (under the Audio I/O menu) and select
the devices you want to use for input and output. Make sure the appropriate faders are raised at the
Windows mixer and/or the audio devices custom mixer.

Revised: 21May10

Quick Start for TrueRTA (v3.5) on Windows 7


Here are step-by-step instructions to get you going quickly. Later, as you wish to learn more about using TrueRTA, you can refer
to the built-in Users Guide under the Help menu.

1) Install the TrueRTA software.


Double-click on the file "TrueRTA_setup.exe" to start the installation process. (Alternately, insert the
TrueRTA CD into your PCs drive and allow the file named "TrueRTA_setup.exe" to auto-play.)
Follow the on-screen instructions to complete the software installation.
2) Configure the Sound System Hardware for Windows 7.
PC sound systems vary greatly so it is up to the user to configure their specific hardware. For testing
purposes simpler is usually better. We will address a basic USB audio interface made by Behringer
and widely available at music stores for under $30. This is the Behringer UCA202 which provides
stereo line-in and line-out on RCA connectors. TrueRTA is initially coarsely calibrated for the
UCA202 USB audio interface shown below.

From the Windows Start button select Control Panel/Sound. Once the Sound control panel opens
select the Recording tab as seen below (left). Next, double-click on the device USB Audio Device
to open the Properties window seen below (right). Note that on Windows 7 the TrueRTA hardware
may appear as either "USB Audio CODEC" or "USB Audio Device".

Select the Levels tab set the level is set to exactly 1 as seen below (left). Next, switch to the
Advanced tab and select 2 channel, 16 bit, 44100 Hz (CD Quality) as seen below (right).
These steps are critical as TrueRTA will not operate with the default audio settings of maximum level
and 1 channel input.
Revised: 21May10

TrueRTA 3.5 Setup for Windows 7, page 2

Click the OK button once to close the Properties window and then click OK again to close the
Sound control panel. Disconnect the TrueRTA USB unit from the first USB port and repeat this setup
sequence for each USB port on your PC that you wish to be setup for use with TrueRTA. You should
only need to do this one time as each USB port remembers its own settings separately from the other
ports.
3) Raise the Windows volume control to maximum.
From the task bar, raise the Windows volume control to maximum.
4) Provide a Test Signal.
With your sound system connected to the PC and configured for Windows 7 you now need to provide
an input signal at the audio interface unit for testing purposes. This could be the output of a
microphone mixer with a microphone connected or the output from a CD or other media player. You
can also patch the line-out directly to the line-in to establish a self-test configuration.
5) Launch the TrueRTA application software.
From the Windows Start button select All Programs then select TrueRTA. If you have
purchased an upgrade to a higher level of performance then this is the time to enter your registration
information as detailed in your registration e-mail.
6) Start the Analyzer and look for the Test Signal.
Start the analyzer running either by clicking on the GO button on the toolbar or by pressing
Alt+Space at the keyboard. The analyzer will start running, various commands will be disabled and
the spectrum of the current input signal will be displayed. Try using the controls in the Analyzer tool
bar at the right to widen the upper and lower dB limits to +20 dBu at the top and -160 dBu at the
bottom. This will insure that the full input range is displayed and that the input signal is not hidden off
screen. The spectrum you see will depend on the test signal you have provided. If you have a mic
connected then you should be able to speak into the mic and see your voice spectrum appear on the
display as the analyzer runs. If you have a CD or other music source connected then you should see
the changing spectrum of the music as it plays. If your hardware is configured for self test you can
expect to see the system noise floor wiggling about until you start the generator to provide a test
signal. Stop the analyzer either by pressing Stop at the toolbar or by pressing Alt+Space again at
the keyboard. Those functions that were disabled while the analyzer was running will become enabled
again once the analyzer is stopped.
Revised: 21May10

TrueRTA 3.5 Setup for Windows 7, page 3

If you have a microphone connected for input, then sing a note and stop the analyzer (Alt + Space) to
freeze the display. You should see multiple peaks on the screen. If you happened to sing (or play) an
A the left most frequency peak might be 220 Hz. This is the fundamental tone of the complex
waveform that constitutes the note. The 2nd harmonic would be 440 Hz; the 3rd harmonic would be 3
times the fundamental, or 660 Hz, and so on.
If you are in self-test mode then you can examine the generator output directly. At the left side of the
screen is the Generator dialog bar. Enter 200 in the Freq. field, select Sine in the Wave section and
set the Amplitude to 0 dBu. Press the On/Off button once to start the generator. You may not hear the
200 Hz wave depending on how your system is configured. With the generator running you should see
a spike at 200 Hz. Stop and start the generator and the spike should disappear and reappear.
Momentarily disconnect the self test patch cable to verify that the signal is actually passing through
the test loop (and not being seen via some other internal computer pathway). The signal should vanish
when you break the connection and appear again after the connection is reestablished.
Stop the analyzer and switch to Oscilloscope mode (at either the toolbar or the Oscilloscope menu).
Start the oscilloscope running to see the test signal in real time. Notice that the dialog bar at the right
has changed to show you customary Oscilloscope controls. Use Stop to freeze the display.
7) After taking a spectrum measurement you can:

Save the workbench data to one of 20 project memories.


Manipulate the data (shift, average, smooth, sum or difference) using the utilities functions.
Save a TrueRTA project file (file type .rta) which includes all 20 memories.
Export the measured data in.txt format.
Overlay plots of various measured responses from the 20 memories for detailed comparison.
Print a report showing the displayed memories along with their notes.

8) Quit TrueRTA.
Quit the TrueRTA application software by pressing Ctrl+Q at the keyboard or by selecting Exit
under the File menu. On exit the software saves your application settings for the next session.
9) Future sessions with TrueRTA.
In the future when you want to use TrueRTA you only need to connect an audio hardware unit and
then launch the TrueRTA software. If you happen to launch the software first then select Audio
Device Selection under the Audio I/O menu so that TrueRTA can re-scan for new audio
hardware.
Troubleshooting
If there is a problem, review the USB port setup in Step 2. If you are using an audio interface other
than the UCA202 open the Audio Device Selection dialog (under the Audio I/O menu) and select
the devices you want to use for input and output. Make sure the appropriate faders are raised at the
Windows mixer and/or the audio devices custom mixer (if any). Especially note the requirement to
set the record level to exactly 1 and the requirement that the record channel be changed from the
default mono setting to 2 Channels.

Revised: 21May10