Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Exclusive bonding
technology provides
cleaner air
Low resistance to airflow
High dust holding
capacity
Available in synthetic
and natural executions
Washable
Applications
Cleaning
Types R15 and R29 are washable to a
limited extent. Types R17, R50 and R20
are fully washable.
The R-series media can be cleaned:
in warm water (30 - 40C) with
addition of a household detergent,
if necessary. Drying should be done
on a flat surface. Do not rub or
wring.
by blowing with compressed air in
opposite direction of filter airflow.
AmerTex R-Serie
Technical Data
Type
R15 Economy
R17 Durable
R29 Standard
R50 Super
1.5
5400
17
130
75 - 80
G2
2 x 20
1 x 20
1.5
5400
17
130
75 - 80
G2
2 x 20
1 x 20
1.5
5400
42
200
87 - 92
G4
2 x 20
1 x 20
2.0
7200
80
250
80
G3
Pads only
white
F1
100
limited
white
F1
100
good
1.5
5400
26
200
80 - 85
G3
2 x 20
1 x 20
polyethylene bags
white
F1
100
limited
white
F1
100
good
brown
65
good
Airflow Resistance
R 20
80
R 50
R 29
70
60
R 17, R 15
50
40
30
20
10
0
0
1.0
2.0
3.0
4.0
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-2-504-IN-4-0198
AmWash
Pleated Washable Filter
Washable
High dust holding capacity and long service life
Reduce the risk of fire
Low initial resistance
Choice of media in the classification range G3 to F5 (EN779)
Lightweight and easy to install
Easy to install
Advantages
Cleanable
AmWash can be blow cleaned with compressed air, but only once
or twice during its natural lifetime. AmWash can also be cleaned
with a solution of water and detergent on a limited basis.
Aluminum frame
Choice of Media
AmWash is available with 3 classifications: G3, F4 and F5 in
accordance with EN779.
Filter media
Supporting grid
AmWash
Technical Specification
Maximum Operating Temperature
Media
Support grid
Frame
Corner bracket
:
:
:
:
:
93C (200F)
Synthetic fiber
Wire grid
Aluminum Frame
Rigid steel bracket
Product Information
Class
Nominal Size
WxHxD (mm)
Actual Size
WxHxD (mm)
Rated Airflow
Capacity (m3/h)
G3
610 x 610 x 51
595 x 595 x 46
3400
35
65
90
G3
305 x 610 x 51
290 x 595 x 46
1700
35
65
90
G3
595 x 595 x 96
3400
30
55
75
G3
290 x 595 x 96
1700
30
55
75
G4
610 x 610 x 51
595 x 595 x 46
3400
50
85
110
G4
305 x 610 x 51
290 x 595 x 46
1700
50
85
110
G4
595 x 595 x 96
3400
45
80
105
G4
290 x 595 x 96
1700
45
80
105
Airflow Resistance
Initial Resistance vs Face Velocity
200
170
150
120
100
75
50
25
0
0
AmAir 300
High Quality Prefilters
Applications
AmAir 300
Technical Data
Type
100 - 2
100 - 4
300 - 2
300 - 4
48
1.5 - 2.5
90 - 95
G4
45 - 85
250
90
95
1.5 - 3.2
90 - 95
G4
40 - 100
250
90
48
1.5 - 2.5
90 - 95
G4
33 - 76
250
90
95
1.5 - 3.2
90 - 95
G4
31 - 91
250
90
Standard Dimensions
12 x 24
16 x 20
16 x 25
20 x 20
20 x 25
24 x 18
24 x 20
24 x 24
141/ 2 x 26 3/ 4
Airflow Resistance
Actual Size2,3)
(mm)
WxH
Airflow
at 2.5 m/s
(m3/h)
290 x 595
392 x 494
392 x 621
494 x 494
494 x 621
595 x 445
595 x 494
595 x 595
355 x 665
1700
1870
2380
2380
2975
2550
2850
3400
2260
Nominal Size
(inches)
WxH
1,3)
160
140
120
1.
100
2.
80
60
40
20
0
0
1.0
1.5
2.0
2.5
3.0 3.2
Notes:
1) Width and height dimensions are interchangeable.
Filters may be installed with the pleats in the
vertical or horizontal position. The pleats are always
parallel to the longest cell side unless explicity
specified otherwise.
2) Other sizes and air filters in 21 mm (1 inch
nominal) depth are available upon request.
3) See Technical Data Table for filter depths.
Fire Classification:
a) Both filters are Class 2 approved and listed according to UL Standard 900.
b) PET media is classified M2 according to NF P92-503, 504 and 505.
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice
RA-2-509-IN-1-0798
DriPak 2000
Superfine Synthetic Fibres Provide Cleaner Air
Temperature limits
DriPak 2000 synthetic filters are designed
for a continuous operating temperature
up to 70C. The filters should not be
stored or transported in conditions where
temperatures exceed 60C.
Efficiency Ranges
DriPak 2000 is available in four
efficiencies. For easy identification, each
efficiency has its own colour coded media
scheme:
Final Resistance
DriPak 2000 filters are tested in
accordance with EN779. The
recommended final resistance is 450 Pa.
Efficiency
EN 779
Media Colour
90 - 95%
80 - 85%
60 - 65%
F8
F7
F6
Yellow
Red
Green
DriPak 2000
Rated
Airflow
Capacity
(m3/h)
Rated
Initial2/3)
Resistance
(Pa)
9
592x592x700
4
287x592x700
7
490x592x700
8
592x592x635
2.5
4
287x592x635
6
490x592x635
6
592x592x508
1.25
3
287x592x508
5
490x592x508
80-85% Average Efficiency2) - F 7
8.0
3.6
6.2
6.7
3.3
5.0
4.1
2.0
3.4
4250
2125
3550
3400
1700
2850
1700
850
1400
160
160
160
135
135
135
90
90
90
9
4
7
8
4
6
6
3
5
8.0
3.6
6.2
6.7
3.3
5.0
4.1
2.0
3.4
4250
2125
3550
3400
1700
2850
1700
850
1400
105
105
105
80
80
80
60
60
60
9
4
7
8
4
6
8.0
3.6
6.2
6.7
3.3
5.0
4250
2125
3550
3400
1700
2850
75
75
75
65
65
65
6
3
5
6
3
5
6
3
5
5.0
2.5
4.3
4.1
2.0
3.4
2.5
1.2
2.0
3400
1700
2850
3400
1700
2850
3400
1700
2850
55
55
55
60
60
60
65
65
65
100
3.2
75
25
0
0
0.5
1.0
1.5
2.0
2.5
3.0
3.2
125
100
75
2.5
50
25
0
0
0.5
1.0
1.5
2.0
2.5
3.0
1.25
592x592x700
287x592x700
490x592x700
592x592x635
287x592x635
490x592x635
592x592x508
287x592x508
490x592x508
120
3.2
90
2.5
60
30
592x592x700
287x592x700
490x592x700
592x592x635
287x592x635
490x592x635
0
0
0.5
1.0
1.5
2.0
2.5
3.0
Number
of
Pockets
125
50
Gross
Media
Area
(m2)
Actual
Size4/5)
(wxhxd)
(mm)
2.5
2.5
2.5
90
60
30
0
0
0.5
1.0
1.5
2.0
2.5
3.0
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
592x592x635
287x592x635
490x592x635
592x592x508
287x592x508
490x592x508
592x592x305
287x592x305
490x592x305
Notes:
1) Filters can be operated at 67% to 133% of rated face velocity.
2) All performance data based on EN779 1993 standard (ASHRAE 52.1-1992 test method).
3) The recommended final resistance is 450 Pa.
4) The DriPak 2000 filter sizes fit into frame sizes 610 x 610, 305 x 610 and 508 x 610 mm.
5) Filters are also available in other sizes and with 25 and 20 mm headers.
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-2-542-IN-2-0999
VariCel
High and Medium Efficiency
Extended Surface
Supported Pleat Air Filters
VariCel
with Intersept
IAQ Engineered Media Treated
with Intersept Antimicrobial
VariCel and
VariCel with
Intersept
Extended Surface
Supported Pleat Filters
U.L. Class 1
VariCel filters with Intersept antimicrobial are designed specifically to improve Indoor Air Quality (IAQ). Air filters are designed to
trap and concentrate particulate air contaminants including viable
fungal and bacterial spores. The presence of Intersept antimicobial preservative in the filter media is intended to preserve the integrity of the media throughout the useful life of the filter.
Antimicrobial preservatives are not meant to increase the efficiency
of the filter, nor to kill microorganisms "on the fly" as they pass
through a filter. Intersept is EPA registered and environmentally
safe.
Cell Side
Potential Leak Path
Rigid construction and minimum depth make VariCel filters easy to install in all types
of systems.
AIRFLOW
COARSE FIBERS
OPERATING DATA
90-95%
90-95% XL/80-85%
VariCel Model
90-95%
60-65%
80-85%
Temperature Limit
350F
177C
Type HT-500
500F
260C
Type HT-725
750F
385C
Type HT-900
900F
482C
Type NH
200F
93C
60-65% XL
Using prefilters, such as AAF's PerfectPleat pleated filters or 5700 panel filters, will greatly extend the life of
VariCel filters.
12" deep filters are rated at 500 FPM filter face velocity.
6" deep filters are rated at 250 FPM filter face velocity.
Recommended final resistance for all VariCel filters is 1.2" wg.
OPTIONS
Efficiency by Particle Size*
100
90
80
EFFICIENCY (%)
70
60
50
.1
.4
.2
.6
.8
8 10
DEC '03
MP 10M
VariCel II
Low Depth Compact Filter
For Commercial and Industrial HVAC Systems
225
90 %
200
175
150
125
60 %
100
75
50
25
0
0
1.0
2.0
3.0
2.5
4.0
VariCel II
Specification
: 65 C
: Dual density glass fibre
: Natural kraft pine and hardwood fibre
: Municipal incinerator
Technical Data
Nominal
Size1)
(wxhxd)
(inches)
Actual
Size1)
(wxhxd)
(mm)
Rated
Air Flow
Capacity2)
(m3/h)
(m3/s)
Rated
Initial2)
Resistance
(Pa)
Gross
Media
Area
(m2)
594x594x97
492x619x97
492x594x97
492x492x97
441x594x97
391x619x97
391x492x97
289x594x97
289x289x97
3400
2975
2805
2380
2550
2380
1870
1700
850
0.944
0.826
0.780
0.661
0.708
0.661
0.519
0.472
0.236
170
170
170
170
170
170
170
170
170
11.80
10.31
9.85
8.18
8.83
8.18
6.50
5.85
2.97
3400
2975
2805
2380
2550
2380
1870
1700
850
0.944
0.826
0.780
0.661
0.708
0.661
0.519
0.472
0.236
100
100
100
100
100
100
100
100
100
11.80
10.31
9.85
8.18
8.83
8.18
6.50
5.85
2.97
594x594x97
492x619x97
492x594x97
492x492x97
441x594x97
391x619x97
391x492x97
289x594x97
289x289x97
1) Width and height dimensions are interchangeable. VariCel II filters can be installed horizontally or vertically.
2) All performance data based on ASHRAE 52: 1.1992. Classification in accordance with EN779.
For maximum service life, VariCel II filters should always be operated with a prefilter.
3) Available for side access installations designed with a 18 mm or 22 mm or customized wide stationary track.
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice
RA-2-599-IN-1-0198
VariPak
Multi-Purpose High Efficiency Compact Filter
VariPak 80%
250
Initial Resistance Pa
Applications
2
3
200
100
50
0
0
0.2
0.4
0.6
Initial Resistance Pa
90
1.4
1.6
1.8
VariPak 90%
70
60
50
40
2.0
5: 96 mm 1.5 m/s
250
80
30
2
3
200
4
5
150
100
50
20
10
0
0
0.5
1.0
1.5
2,0
0.5
5: 96 mm 1.5 m/s
1.0
1.5
2.0
1.2
4
Initial Resistance Pa
1.0
5
100
0.8
VariPak 60%
The Filter
4
5
150
5: 96 mm 1.5 m/s
VariPak
Operating Temperature
Disposal
Item
A
B
Filter Type
Efficiency
VP = VariPak
6 = 60 - 65%
9 = 80 - 85%
10 = 90 -95%
10 = die - cut, 11 = Aluminium extrusion
72 = MDF
89 = Aluminized steel
99 = Aluminium extrusion
90 = Aluminium extrusion with 20 mm flange for 3 media
P = 25 mm
R = 35 mm
K = 48 mm
M = 96 mm
L = 72 mm
9 = Polyurethane
2 = polyurethane flame retandant
0 = none on filters with die-cut cell sides
S = foamed polyurethane
P = No gasket
T = neoprene 6 mm
A = special
0 = none
2 = air leaving side
1 = air entering side
3 = both sides
P = none
A = Aluminium
E = epoxy coated steel U = Aluminized expanded metal
Z = special
0 = none
1 = Air leaving side
2 = Air entry side
3 = Both sides
Cell sides
Pack Depth
Bond
Component
Gasket type
Gasket location
Faceguard
Faceguard location
Size in mm
without gasket
H x
W x D
Nominal
airflow
m3/h
m3/s
2000
2000
0,55
0,55
2000
2000
0,55
0,55
1740
1740
0,48
0,48
1340
1340
0,37
0,37
1340
1340
0,37
0,37
96 mm pack
610 x 610 x 292
610 x 610 x 149
72 mm pack
610 x 610 x 292
610 x 610 x 149
48 mm pack
610 x 610 x 78
610 x 610 x 149
35 mm pack
610 x 610 x 78
610 x 610 x 56
25 mm pack
610 x 610 x 78
610 x 610 x 56
How to Order
Below a typical example of the Style Code for a standard VariPak filter using the
Component Definition Code System.
Item
Component
Definition
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
VP
72
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice
RA-2-509-IN-1-0699
VariCel V
Lightweight Compact Filters For Commercial and
Industrial HVAC Systems
Lightweight and
easy to install
Classification ranges
F6, F7, F8 and F9
Excellent performance
in difficult operating
conditions
High air volume capacity:
upto 5000 m3/h
High dust holding
capacity
Airflow Resistance
VV6-series
200
175
150
125
100
75
50
25
0
95%
90%
80%
60%
1.0
2.0
3.0
4.0
Face Velocity (m/s)
Varicel V
Specifications
Maximum operating temperature
Media
Separators
Cell Sides
:
:
:
:
70 C
Ultra fine glass fibres woven into mat
Thermoplastic
Recycled polystyrene
Technical Data
Average
Efficiency2)
%
EN
779
Class2
Initial
Resistance
at Nominal
Airflow (Pa)
Final
Resistance3)
60-65
60-65
60-65
80-85
80-85
80-85
90-95
90-95
90-95
> 95
> 95
> 95
6
6
6
7
7
7
8
8
8
9
9
9
110
110
110
125
125
125
145
145
145
180
180
180
600
600
600
600
600
600
600
600
600
600
600
600
Airflow
Type
VV6- 6-24.24-124)
VV6- 6-20.24-124)
VV6- 6-12.24-124)
VV6- 9-24.24-12
VV6- 9-20.24-12
VV6- 9-12.24-12
VV6-10-24.24-12
VV6-10-20.24-12
VV6-10-12.24-12
VV6-11-24.24-12
VV6-11-20.24-12
VV6-11-12.24-12
1)
2)
3)
4)
Size1)
(mm)
HxWxD
592 x 592 x 292
490 x 592 x 292
287 x 592 x 292
592 x 592 x 292
490 x 592 x 292
287 x 592 x 292
592 x 592 x 292
490 x 592 x 292
287 x 592 x 292
592 x 592 x 292
490 x 592 x 292
287 x 592 x 292
Maximum
Nominal
m3/h
m3/s
m3/h
m3/s
5000
4165
2500
5000
4165
2500
5000
4165
2500
5000
4165
2500
1,39
1,15
0,69
1,39
1,15
0,69
1,39
1,15
0,69
1,39
1,15
0,69
4250
3540
2125
4250
3540
2125
4250
3540
2125
4250
3540
2125
1,18
0,98
0,59
1,18
0,98
0,59
1,18
0,98
0,59
1,18
0,98
0,59
(Pa)
Width and height are interchangeable, pleats can be either vertical or horizontal without affecting performance.
All performance data based on EN779.
Recommended maximum value. Filters can be operated to a lower final resistance without materially effecting filter efficiency.
Suffix "C" denotes cellulose media option.
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-2-08-IN-4-0198
BioCel I
High Quality HEPA Filter For Use In Clean Zones
Airflow range:
500 - 2000 m3/h
Classified H11 in
accordance with EN1822
Benefits in existing and
new installations
Lower energy costs
149 mm
250
292 mm
200
150
100
50
0
0
0.37
0.75
1.13
1.5
1.87
2.25
BioCel I
Technical Data
Size
(mm)
H11
H11
2000
1000
165
165
3000
1500
250
250
98
98
Media Area
m2
14.6
6.8
Dimensions
Media
Cell sides
Separators
Bond
Gasket
Disposal
Temperature limit
Style code
:
:
:
:
:
:
:
:
:
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-2-527-IN-1-0897
BioPak
High Quality HEPA Filters
H11 classified in
accordance with EN1822
Recessed pack ensures
easy handling
Non-shedding
MDF cell sides
Low resistance ensures
low energy consumption
One-piece gasket
provides leaktight seal
0
0
0.30
0.45
0.60
0.75
0.90
1.05
1.20
1.37
1.50
BioPak
Technical Data
Size
(mm)
610 x 610 x 78
610 x 610 x 149
610 x 610 x 292
H11
H11
H11
600
1000
1000
90
120
90
1000
1500
2000
120
180
250
98
98
98
Media Area
m2
8.8
8.8
17.5
Dimensions
Media
Cell sides
Separators
Bond
Gasket
Disposal
Temperature limit
Style code
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-2-539-IN-1-0897
BioCel V
High Quality Compact HEPA Filter for HVAC Systems
H10 classification in
accordance with EN1882
High air capacity:
3000 m3/h
Reduced energy costs
and long service life
Lightweight and
easy to install
40
20
0
0
0.37
0.75
1.13
1.5
1.87
2.25
BioCel V
Technical Data
Size
(mm)
Classification
EN1822
H10
H10
Low Airflow
Initial
High Airflow
m3/h
Resistance (Pa)
m3/h
2000
1000
120
120
3000
1500
Initial
Efficiency*
Resistance (Pa) % @ 0.3 m
200
250
95
95
Media Area
m2
20.4
9.0
Dimensions
Media
Cell sides
Separators
Disposal
Temperature limit
Style code
:
:
:
:
:
:
:
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-2-541-IN-2-0899
AstroCel I
High Efficiency Particulate Air Filter (HEPA)
400
3
350
300
250
200
150
100
50
0
0
0.25
0.50
0.75
1.0
1.25
1.5
1.75
2.0
2.25
AstroCelI
An AstroCel I can be ordered using the following Component Code Definition System.
Use the table to specify a product suitable to your application requirements.
Selection Table
Item
Component
Media
Cell Sides
C
D
Separators
Bond
Gasket
Gasket Location
Acceptance Level
A
E
24
26
72
J
5
9
P
S
T
Y
0
2
3
H
R
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Size in mm
without gasket1)
How to Order
Below a typical example of how to order a standard AstroCel I filter using
the Component Code Definition System.
Item
Component
Definition
72
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
Nominal
airflow
m3/h
m3/s
610
610
610
610
610
610
305
610
762
305
610
762
149
149
149
292
292
292
500
1000
1250
1000
2000
2500
0.14
0.28
0.35
0.28
0.56
0.69
Efficiency
Efficiency
@ 0.3 m
99.997%
99.999%
Efficiency EN1822
@ MPPS
H13
99.95%
H14
99.995%
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-4-701-IN-3-1299
AstroCel I HC
High Quality HEPA Filter
350
300
250
200
150
100
50
0
0
0.25
0.50
0.75
1.0
1.25
1.5
1.75
2.0
2.25
AstroCel I HC
An AstroCel I HC can be ordered using the following Component Code Definition System.
Use the table to specify a product suitable to your application requirements.
Selection Table
Item
Component
Media
Cell Sides
C
D
E
Separators
Bond
Gasket
Gasket Location
A =
E =
24 =
26 =
72 =
H =
9 =
P =
S =
T =
0 =
2 =
3 =
G =
H =
R =
Acceptance Level
Size in mm
without gasket
How to Order
Below a typical example of how to order a standard AstroCel I HC filter using the
Component Code Definition System.
Item
Component
Definition
72
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
Nominal
airflow
m3/h
m3/s
610
610
610
305
610
762
292
292
292
1500
3000
3750
0.42
0.83
1.04
Efficiency
Efficiency
@ 0.3 m
99.99%
99.997%
99.999%
Efficiency EN1822
@ MPPS
H12
99.5%
H13
99.95%
H14
99.995%
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-4-721-IN-3-1299
AstroPak
High Efficiency Particulate Air Filter
Non-shedding
construction
Leakfree construction
Filter class H13 and H14
according to EN1822
350
300
250
200
150
100
50
0
0
0.25
0.50
0.75
1.0
1.25
1.5
1.75
AstroPak
An AstroPak can be ordered using the following Component Code Definition System.
Use the table to specify a product suitable to your application requirements.
Selection Table
Item
Component
Media
Cell Sides
Media pack
D
E
Bond
Gasket
Gasket Location
Acceptance Level
A
E
24
72
K
M
9
P
S
T
0
2
3
H
R
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Size in mm
without gasket1)
How to Order
Below a typical example of how to order a standard AstroPak filter using
the Component Code Definition System.
Item
Component
Definition
A
A
B
72
C
K
D
9
Efficiency
Efficiency
@ 0.3 m
99.997%
99.999%
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
Efficiency EN1822
@ MPPS
H13
99.95%
H14
99.995%
E
S
F
2
G
H
Nominal
airflow
Pack
Depth
m3/h
m3/s
mm
240
610
490
610
305
457
305
610
203
305
610
457
610
610
610
610
610
610
762
762
762
762
762
915
915
915
915
305
610
610
610
240
305
490
610
305
457
610
610
203
305
305
457
610
762
915
1220
1524
1830
762
915
1220
1524
1830
915
1220
1524
1830
305
305
610
762
56
56
56
56
78
78
78
78
149
149
149
149
149
149
149
149
149
149
149
149
149
149
149
149
149
149
149
292
292
292
292
155
500
650
1000
250
570
500
1000
110
250
500
570
1000
1250
1500
2000
2500
3000
1600
1900
2500
3150
3800
2250
3000
3800
4550
500
1000
2000
2500
0.04
0.14
0.18
0.28
0.07
0.16
0.14
0.28
0.03
0.07
0.14
0.16
0.28
0.35
0.42
0.56
0.69
0.83
0.44
0.53
0,69
0.88
1.06
0.63
0.83
1.06
1.26
0.14
0.28
0.56
0.69
48
48
48
48
48
48
48
48
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-3-535-IN-3-1299
300
250
200
150
100
50
0
0
0.50
1.00
1.50
2.00
2.50
3.00
Selection Table
Item
Component
Size in mm
without gasket
A
B
C
D
E
F
Type of Filter
Media
Cell Sides**
Separators
Bond
Gasket
Gasket Location
Acceptance Level
I
K
Faceguard Location
Options
Nominal
airflow
m3/h
610
610
305
610
292
292
1500
3400
Notes:
- Recommended final resistance 750 Pa.
- Temperature limit 70C.
- Initial resistance at nominal airflow: 250 Pa.
Efficiency
Efficiency
@ 0.3 m
99.97%
99.99%
Efficiency EN1822
@ MPPS
H12
99.5%
H13
99.95%
How to Order
Below a typical example of how to order a standard AstroCel III 3400 filter using
the Component Code Definition System.
Item
Component
Definition
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
A39
72
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-4-139-IN-3-1299
1,000 (M4.5)
10,000 (M5.5)
100,000 (M6.5)
100
Narrow
min. 3
20
Minimum
300
3:1
min. 2.75
10
30% Floor
500
2:1
min 2.25
5
50% Floor
Occupant activity
Traffic in/out per hour
Occupants properly attired
Particle generation in room
Thermal updrafts
Housekeeping
Sedentary
1-2
Full gowns
Miniature
None
Meticulous
Occasional movement
2-6
Smocks
Slight
Slight
Good
Constant activity
More than 6
Smocks
Considerable
Considerable
Mediocre
Frivolous activities
10-15
40-120
Adequate
10-15
20-40
Small
5-10
10-20
None
None
20-50
Ceiling
0.15-0.45
Low level or floor
Continuous on all
4 walls
3
0.5-1
10-20
Ceiling
0.15-0.45
Low sidewall
Intermittent on long
walls
6
1-2.5
5-10
Ceiling or high sidewall
0.15-0.45
Sidewall
Non-uniform
9
2.5
90% arrestance
G4
80-90% dust spot eff.
F7
Semi-annual
80% arrestance
G4
80-90% dust spot eff.
F7
Annual
Final Filters**
min.99.999% @ 0.3 m
H14
Monthly
Monthly
Quarterly
Avoid
Street clothes
Floor
Ceiling
Single
Doors open
No schedule
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
AAF Agents:
Copenhagen (DK), Oslo (N),
Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
CR-2-741-IN-0896
Horizontal Crossflow
In a horizontal crossflow cleanroom, the
direction of airflow is from left to right
or right to left across the room. Air
enters the room via filters in one wall
and is exhausted and/or recirculated via
a bank of filters and perforated panels in
the opposite wall. The air velocity has to
be established at a sufficiently high level,
Vertical Downflow
In a vertical downflow cleanroom, air
enters the room via filters in the ceiling
surface and is exhausted via a perforated
100 (M3.5)
40 m2
Full gowns
Minimum
Minimum
Meticulous
30 m2
Full gowns
Minimum
Minimum
Meticulous
Room pressurized
Air changes per hour
Air lock
15 Pa
500-600
Yes
15 Pa
500
Yes
90-100%
Ceiling
0.3 - 0.45 m/s
Perforated floor
90%
Ceiling (wall)
0.3 - 0.45 m/s
Low level or floor
(opposite wall, 0.45 m/s)
Daily
Weekly
Prefilters:
- First stage**
- Second stage**
Prefilter maintenance and inspection
Final filters**
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
CR-2-740-IN-0896
EN779
New European Standard for Coarse and Fine Filters
Filter
Classification
Average Arrestance
A (%)
Average Efficiency
Em (%)
G1
G2
G3
G4
F5
F6
F7
F8
F9
Am < 65
65 Am < 80
80 Am < 90
90 Am
-
40 Em < 60
60 Em < 80
80 Em < 90
90 Em < 95
95 Em
Eo < 20%
Eo 20%
Note:
For your information, the CEN/TC 195 Work Group 1 will continue to upgrade its standardization for general ventilation filters.
To this end, EUROVENT has produced a particle count method under document name EUROVENT 4/9 which will form the
basis for a future new standard. WG 1 has also expressed its intention to work in closer liaison with ASHRAE on this subject.
CR-3-1167-IN-0896
EN1822
New European Standard for HEPA & ULPA Filters
Minimum
Efficiency
Face Velocity 5.00 cm/s
(Resistance = 36.36 mm)
(MPPS = 0.134 m)
Procedure
Penetration (%)
99.9975
99.99975
99.9999
0.0005
0.00005
0.000005
0.0025
0.00025
0.0001
Notes:
Filters in the class H10, H11 and H12 do not require verification of local penetration.
Filters in the classification H13 and H14 may, as an alternative, be verified with the visual oil-smoke test (previously known as DIN 24.184),
which is accepted as equal or more searching than the specified local penetration.
U17 is an exception to the rule. In this case local penetration may not exceed 20 x the overall penetration value.
CR-2-489-IN-1-0398
AstroFan FFU
Self-contained Filter Fan Unit
Application
Construction
Noise level
The AAF AstroFan FFU is a selfcontained ceiling filter fan unit for
use in turbulent mixing and laminar
air flow cleanroom areas. The unit is
designed for use with the AAF
50 and 55 mm T-Bar ceiling grid,
the AstroDry HD ceiling grid and
compatible grids. When executed
with a knife edge, the unit can also
be utilized in the AstroGel ND
liquid seal ceiling grid. The unit is
light weight and easy to install.
AstroFan FFU
Options
Performance Data
Size
66
612
912
1212
Airflow
(m3/h / m3/s?
520 / 0.14
1060 / 0.3
1590 / 0.44
2120 / 0.6
Actual Dimensions
L x W x H* (mm)
0.26 kW - 1.2 A
0.21 kW - 0.5 A
0.17 kW - 0.75 A
0.29 kW - 1.3 A
0.23 kW - 0.55 A
0.22 kW - 0.98 A
0.52 kW - 2.2 A
0.43 kW - 0.88 A
0.34 kW - 1.5 A
0.68 kW - 3.0 A
0.61 kW - 1.18 A
0.34 kW - 1.5 A
45
35
65
72
Nominal
Motor Data
230/1/50
400/3/50
EC 230/1/50/60
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98
AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)
AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice
CR-3-1168-IN-3-0101