Sei sulla pagina 1di 40

AmerTex R-Serie

Synthetic and natural filter media

Exclusive bonding
technology provides
cleaner air
Low resistance to airflow
High dust holding
capacity
Available in synthetic
and natural executions
Washable

R-series air filter media is made of


synthetic fibres, except type R20
Natural, which is made of natural fibres.
An exclusive bonding technology
ensures a high number of fibres per
square metre for a given weight.

Natural filter media

Synthetic filter media.

The R20 Natural media, consisting of


latex coated natural fibres structured
into a porous and dense media, is
recommended for use in severe
operating conditions.

The R15 Economy and R17 Durable


media are recommended for use in low
pressure forced air convectors, window
ventilation units, fan coils and as
prefilter in paintspray cabins.

All AmerTex R series media is white


coloured. No colour pigments are
needed to create a distinction between
the various media. The name of each
product together with its classification
according to EN779 is printed at
regular intervals on the air leaving side
of each media roll, permitting easy
product identification. R-Series media is
characterized by a relatively low
resistance to airflow and a high dust
holding capacity.

Applications

Cleaning
Types R15 and R29 are washable to a
limited extent. Types R17, R50 and R20
are fully washable.
The R-series media can be cleaned:
in warm water (30 - 40C) with
addition of a household detergent,
if necessary. Drying should be done
on a flat surface. Do not rub or
wring.
by blowing with compressed air in
opposite direction of filter airflow.

The R29 Standard media is for use in


room air conditioning units, hot air
generators, air conditioning installations,
home kitchen hoods and as prefilter in
paint spray cabins.
The R50 Super media is suitable for use
in air conditioning installations in the
food industry, kitchen hoods, industrial
ventilation systems and as prefilter in
paintspray cabins.

AmerTex R-Serie

Technical Data
Type

R15 Economy

R17 Durable

R29 Standard

R50 Super

R20* (30 mm)

1.5
5400
17
130
75 - 80
G2
2 x 20
1 x 20

1.5
5400
17
130
75 - 80
G2
2 x 20
1 x 20

1.5
5400
42
200
87 - 92
G4
2 x 20
1 x 20

2.0
7200
80
250
80
G3
Pads only

white
F1
100
limited

white
F1
100
good

1.5
5400
26
200
80 - 85
G3
2 x 20
1 x 20
polyethylene bags
white
F1
100
limited

white
F1
100
good

brown
65
good

Recommended face velocity (m/s)


Rated capacity (m3/h/m2)
Rated initial resistance (Pa)
Recommended final resistance (Pa)
Average arrestance (%)
EN 779 classification
Roll size (m)
Packing
Media colour
Flame retardancy according to DIN 53438
Max. operating temperature (C)
Washability

* R20 media is also available in 20, 40 and 50 mm thicknesses

Initial Resistance (Pa)

Airflow Resistance
R 20

80

R 50
R 29

70
60

R 17, R 15

50
40
30
20
10
0
0

1.0

2.0

3.0

4.0

Face Velocity (m/s)

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-2-504-IN-4-0198

1998 AAF International

AmWash
Pleated Washable Filter

Washable
High dust holding capacity and long service life
Reduce the risk of fire
Low initial resistance
Choice of media in the classification range G3 to F5 (EN779)
Lightweight and easy to install

AmWash is specially designed for application in industrial and


commercial heating, ventilation and air conditioning systems. For
example like:
1) Offices, convention centers, meeting rooms, hospitals,
shopping malls, sport centers, airports and other buildings
with HVAC systems.
2) Normal industrial area with central air ventilation system.
3) Prefilter for central ventilation system for CleanRoom.

Easy to install

Advantages

Cleanable

AmWash is a lightweight panel filter with several special features


like reusable aluminum steel frame, made of synthetic fiber and
characterized by a relatively low resistance to airflow, reduce risk of
fire, washable and easy to install. Filter media with the thickness of
10mm and 20mm ensure high dust holding capacity.

AmWash can be blow cleaned with compressed air, but only once
or twice during its natural lifetime. AmWash can also be cleaned
with a solution of water and detergent on a limited basis.

AmWash has a sturdy, long lasting galvanized steel frame which


offers great resistance in harsh operating conditions. Due to its light
weight and compact size (only 46mm depth), it is relatively
inexpensive to ship and easy to handle and install. If required,
AmWash can be supplied with a stainless steel or aluminum frame
and can be manufactured to any size.

Aluminum frame

Choice of Media
AmWash is available with 3 classifications: G3, F4 and F5 in
accordance with EN779.

Filter media
Supporting grid

High dust holding capacity


Owing to the excellent dust holding capacity, AmWash can be used
as prefilter to higher efficiency filters or as main filters. As prefilter,
AmWash protect more expensive main filters from premature
replacement while as main filter it improves the quality of indoor air.

AmWash
Technical Specification
Maximum Operating Temperature
Media
Support grid
Frame
Corner bracket

:
:
:
:
:

93C (200F)
Synthetic fiber
Wire grid
Aluminum Frame
Rigid steel bracket

Product Information
Class

Nominal Size
WxHxD (mm)

Actual Size
WxHxD (mm)

Rated Airflow
Capacity (m3/h)

G3

610 x 610 x 51

595 x 595 x 46

3400

35

65

90

G3

305 x 610 x 51

290 x 595 x 46

1700

35

65

90

G3

610 x 610 x 102

595 x 595 x 96

3400

30

55

75

G3

305 x 610 x 102

290 x 595 x 96

1700

30

55

75

G4

610 x 610 x 51

595 x 595 x 46

3400

50

85

110

G4

305 x 610 x 51

290 x 595 x 46

1700

50

85

110

G4

610 x 610 x 102

595 x 595 x 96

3400

45

80

105

G4

305 x 610 x 102

290 x 595 x 96

1700

45

80

105

Initial Resistance (Pa)via Rated Airflow


70%
100%
120%

Airflow Resistance
Initial Resistance vs Face Velocity

Initial Resistance (Pa)

200
170
150
120
100
75
50
25
0
0

Face Velocity, (m/s)

No. 9 (Lot 136), Jalan Juru Ukur U1/19,


Hicom-Glenmarie Industrial Park, 40150
Shah Alam, Selangor Darul Ehsan, Malaysia.
www.aafasia.com

Tel: 03-5569 2633 / Fax: 03-5569 3633

ISO-9001 Certified Firm


AAF has a policy of continuous product research
and improvement and reserves the right to change
design and specifications without notice.
2006 AAF Malaysia
AMWASH-01-MAL/OCT 06

AmAir 300
High Quality Prefilters

Excellent media performance in high humidity


conditions
High tensile strength
media
Environment-friendly
materials
Sturdy, reliable
construction

With the new AmAir 100 and 300


series of prefilters AAF has risen to
the challenge of designing an
environment-friendly product with
the necessary performance characteristics built-in. These filters feature
a new 100% synthetic media pack
which provides excellent performance in conditions of high relative
humidity and moisture. When the
media becomes wet, resistance may
rise temporarily only to subside when
the media starts to dry. The synthetic
media displays great tensile strength,
reducing the chance of damage
during handling and operation. The
media is environment and user

between pleats, ensuring that dust is


collected evenly over the entire
surface of the media. Media usage is
maximized resulting in a more
gradual rise in resistance, which in
turn has a positive effect on energy
consumption and service life.

friendly: it does not contain any


harsh resins or artificial colouring. It
can therefore be readily disposed of
by landfill or incineration.

High performance, environment


friendly media

Sturdy, reliable construction

The pleated media pack of both


range of filters is housed within a
sturdy double walled, die cut box,
beverage board frame. To ensure the
media pack does not rack or
deteriorate under difficult operating
conditions, it is bonded to the inside
of its frame at all points of contact
and retained in position by retainers
at the air leaving and air entering
sides. On the air leaving side of the
media pack a wiremesh pleat support
grid maintains equidistant spacing

Applications

Classified G4 in accordance with


EN 779, AmAir 100 and 300 are
ideal for protecting more expensive
secondary air filters from premature
dust loading and replacement. As
primary filters, they will also help
reduce HVAC maintenance costs by
preventing unnecessary dust build-up
on coils, fans and duct work.

AmAir 300

Technical Data
Type

100 - 2

100 - 4

300 - 2

300 - 4

Actual Depth (mm)


Rated Face Velocity (m/s)
Average Arrestance1) (%)
Efficiency1) (%)
EN779 Classification
Rated Initial Resistance1) (Pa)
Recomm. Final Resistance2) (Pa)
Temperature Limits (C)
(continuous operation)

48
1.5 - 2.5
90 - 95
G4
45 - 85
250
90

95
1.5 - 3.2
90 - 95
G4
40 - 100
250
90

48
1.5 - 2.5
90 - 95
G4
33 - 76
250
90

95
1.5 - 3.2
90 - 95
G4
31 - 91
250
90

1) All data based on EN779.


2) Recommended final resistance not to be exceeded.

Standard Dimensions

12 x 24
16 x 20
16 x 25
20 x 20
20 x 25
24 x 18
24 x 20
24 x 24
141/ 2 x 26 3/ 4

Airflow Resistance

Actual Size2,3)
(mm)
WxH

Airflow
at 2.5 m/s
(m3/h)

290 x 595
392 x 494
392 x 621
494 x 494
494 x 621
595 x 445
595 x 494
595 x 595
355 x 665

1700
1870
2380
2380
2975
2550
2850
3400
2260

Initial Resistance (Pa)

Nominal Size
(inches)
WxH

1,3)

1. AmAir 300 (48 mm), 2. AmAir 300 (95 mm)

160
140
120
1.

100

2.

80
60
40
20
0
0

1.0

1.5

2.0

2.5

3.0 3.2

Rated Velocity (m/s)

Notes:
1) Width and height dimensions are interchangeable.
Filters may be installed with the pleats in the
vertical or horizontal position. The pleats are always
parallel to the longest cell side unless explicity
specified otherwise.
2) Other sizes and air filters in 21 mm (1 inch
nominal) depth are available upon request.
3) See Technical Data Table for filter depths.

Fire Classification:
a) Both filters are Class 2 approved and listed according to UL Standard 900.
b) PET media is classified M2 according to NF P92-503, 504 and 505.

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice
RA-2-509-IN-1-0798

1998 AAF International

DriPak 2000
Superfine Synthetic Fibres Provide Cleaner Air

Filter classes F5 - F8 for


applications requiring
cleaner air
Mechanically strong with
a high abrasional
resistance
Operational reliability in
high airflow and high
dust loading conditions
Excellent performance in
high moisture conditions

synthetic fibres with a thin layer of high


strength spunbond scrim on the air
leaving side to increase filter stability and
prevent particle migration. This dual
media design ensures a low initial pressure
drop, a high dust holding capacity and a
long filter service life.

Mechanically Strong and Robust


DriPak 2000 pocket filters are made of
high quality synthetic media. They are
renowned for their high performance
characteristics in applications requiring a
high dust holding capacity and higher air
cleaning capacity. Built from strong,
robust materials they display excellent
abrasional resistance and perform well in
100% relative humidity and in high
airflow and heavy dust loading
conditions. Since their introduction they
have proven a resounding success with the
pharmaceutical, food processing and
automotive industries.

Temperature limits
DriPak 2000 synthetic filters are designed
for a continuous operating temperature
up to 70C. The filters should not be
stored or transported in conditions where
temperatures exceed 60C.

Efficiency Ranges
DriPak 2000 is available in four
efficiencies. For easy identification, each
efficiency has its own colour coded media
scheme:

Microfine Synthetic Fibres


Provide Cleaner Air
DriPak 2000 pocket media comprises a
unique matrix of primary and secondary

Final Resistance
DriPak 2000 filters are tested in
accordance with EN779. The
recommended final resistance is 450 Pa.

Efficiency

EN 779

Media Colour

90 - 95%
80 - 85%
60 - 65%

F8
F7
F6

Yellow
Red
Green

DriPak 2000

Initial Resistance (Pa)

Resistance Curves and Selection Chart Data


Rated
Face
Velocity1)
(m/s)

DriPak 2000 90%


225
200
175
150

Rated
Airflow
Capacity
(m3/h)

Rated
Initial2/3)
Resistance
(Pa)

9
592x592x700
4
287x592x700
7
490x592x700
8
592x592x635
2.5
4
287x592x635
6
490x592x635
6
592x592x508
1.25
3
287x592x508
5
490x592x508
80-85% Average Efficiency2) - F 7

8.0
3.6
6.2
6.7
3.3
5.0
4.1
2.0
3.4

4250
2125
3550
3400
1700
2850
1700
850
1400

160
160
160
135
135
135
90
90
90

9
4
7
8
4
6
6
3
5

8.0
3.6
6.2
6.7
3.3
5.0
4.1
2.0
3.4

4250
2125
3550
3400
1700
2850
1700
850
1400

105
105
105
80
80
80
60
60
60

9
4
7
8
4
6

8.0
3.6
6.2
6.7
3.3
5.0

4250
2125
3550
3400
1700
2850

75
75
75
65
65
65

6
3
5
6
3
5
6
3
5

5.0
2.5
4.3
4.1
2.0
3.4
2.5
1.2
2.0

3400
1700
2850
3400
1700
2850
3400
1700
2850

55
55
55
60
60
60
65
65
65

100

3.2

75

25
0
0

0.5

1.0

1.5

2.0

2.5

3.0

Face Velocity (m/s)

DriPak 2000 80%


225
200
175
150

3.2

125
100
75

2.5

50
25
0
0

0.5

1.0

1.5

2.0

2.5

3.0

Initial Resistance (Pa)

Face Velocity (m/s)


DriPak 2000 60%

1.25

592x592x700
287x592x700
490x592x700
592x592x635
287x592x635
490x592x635
592x592x508
287x592x508
490x592x508

60-65% Average Efficiency2) - F 6

120

3.2

90

2.5

60

30

592x592x700
287x592x700
490x592x700
592x592x635
287x592x635
490x592x635

50-55% Average Efficiency2) - F 5

0
0

0.5

1.0

1.5

2.0

2.5

3.0

Face Velocity (m/s)

Initial Resistance (Pa)

Number
of
Pockets

90-95% Average Efficiency2) - F 8

125

50

Initial Resistance (Pa)

Gross
Media
Area
(m2)

Actual
Size4/5)
(wxhxd)
(mm)

2.5
2.5

DriPak 2000 50%


120

2.5

90

60

30
0
0

0.5

1.0

1.5

2.0

2.5

3.0

Face Velocity (m/s)

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

592x592x635
287x592x635
490x592x635
592x592x508
287x592x508
490x592x508
592x592x305
287x592x305
490x592x305

Notes:
1) Filters can be operated at 67% to 133% of rated face velocity.
2) All performance data based on EN779 1993 standard (ASHRAE 52.1-1992 test method).
3) The recommended final resistance is 450 Pa.
4) The DriPak 2000 filter sizes fit into frame sizes 610 x 610, 305 x 610 and 508 x 610 mm.
5) Filters are also available in other sizes and with 25 and 20 mm headers.

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-2-542-IN-2-0999

1999 AAF International

VariCel
High and Medium Efficiency
Extended Surface
Supported Pleat Air Filters

VariCel
with Intersept
IAQ Engineered Media Treated
with Intersept Antimicrobial

VariCel and
VariCel with
Intersept
Extended Surface
Supported Pleat Filters

Available In Three Efficiencies 90-95% (MERV 14),


80-85% (MERV 13), 60-65% (MERV 11)

Available with Intersept in 90-95% & 60-65%


efficiency

U.L. Class 1

Ideal For Difficult Operating Conditions


-

Variable air volume


Turbulent airflow
Repeated fan shutdown
High temperature operation
High humidity
Intermittent exposure to water
such as seacoast installations

Designed To Improve Indoor Air Quality

VariCel filters with Intersept antimicrobial are designed specifically to improve Indoor Air Quality (IAQ). Air filters are designed to
trap and concentrate particulate air contaminants including viable
fungal and bacterial spores. The presence of Intersept antimicobial preservative in the filter media is intended to preserve the integrity of the media throughout the useful life of the filter.
Antimicrobial preservatives are not meant to increase the efficiency
of the filter, nor to kill microorganisms "on the fly" as they pass
through a filter. Intersept is EPA registered and environmentally
safe.

Engineered For A Variety Of Applications

Type SH Single Header VariCel filters are designed for


systems originally supplied by AAF International. A
unique 1316" flanged header on the air entering side allows the filter to be easily inserted and latched into front and
side access systems.

Type DH Double Header VariCel filters are designed to


upgrade air cleaning performance and reliability. Two
13
16" thick flanged headers make the filters compatible
with the holding frames and latching devices of various manufacturers, including rear access systems.
XL Series VariCel filters, single header (XL-S) and double header
(XL-D), contain up to 67% more media and offer more than twice the
service life of standard single and double header models.
High Temp Series VariCel filters are designed for systems operating from 350-900F. Constructed of aluminized steel, High Temperature VariCel filters offer
rated efficiency with proven reliability over the life of the filter.
See page 4 for models and temperature limits.
Type NH Series VariCel filters are designed for special
sizes and applications, including incineration and
compaction disposal systems. Manufactured of fireretardant, 34" thick, heavy wall particle board, Type NH VariCel
filters (U.L. Class 1) are operable at temperatures up to 200F.
The filters are constructed without headers and cell sides are
flush with front face dimensions.

BUILT RUGGED FOR DEPENDABLE PERFORMANCE

Crimped Rear Flanges (SH) are rolled


over and riveted to add strength, eliminate sharp edges, and prevent bypass
leakage.

Media Pack Restraint


Steel brace on air leaving
side adds support to the
media pack.
Corrugated Aluminum Separators
with Rolled Edges maintain uniform
pleat spacing for optimum airflow. The
separators are rolled to eliminate
sharp edges, preventing media damage during shipping and personal injury during installation.

VariCel's rigid construction


with supported pleat media
pack maintains a compact,
unitized structure even under
tough operating conditions.
Variable air velocity and repeated fan shutdown do not
compromise performance.
Unitized Construction
Interlocked header and cell
sides, along the entire length
of each side, provide maximum sealing. Competitive filters are designed with loose
fitting headers which allow
greater potential for bypass
leakage.
Header
VariCel
Construction
Cell Side
Header
Typical
Competitive
Construction

Pleats and Separators


Bonded For Strength
During the pleating process,
spots of glue are applied to
bond each separator to the adjacent pleat. This solidifies the
media pack to minimize movement and prevent media damage. Burst strength is
increased to prevent the filter
from blowing out under variable air volume conditions or
unusually high resistance.
Galvanized steel headers and
cell sides resist damage during
shipping and handling, and
prevent corrosion over long
service life. (HT VariCel filters
are constructed of aluminized
steel.)
Easy Installation

Cell Side
Potential Leak Path

Media Pack Sealant A layer


of high efficiency media seals the
media pack into the cell sides.
The media sealant prevents bypass leakage and damage to the
media and separators during
shipping and handling. By allowing slight movement of the media
pack when the filter is jarred, the
cushioning sealant helps prevent
tears and punctures to the media.

Rigid construction and minimum depth make VariCel filters easy to install in all types
of systems.

DUAL DENSITY MEDIA


REDUCES OPERATING COSTS

VariCel media is manufactured


with two layers of glass fibers:
coarser fibers on the air entering
side and finer fibers on the air
leaving side.

AIRFLOW

COARSE FIBERS

Air entering side

Our dual density design allows


FINER FIBERS
dirt particles to be collected
Air leaving side
throughout the entire depth of
the filter utilizing the full cleaning potential of the media. Maximum dust holding capacity extends the life of the filter, minimizing operating costs.
The water resistant media can withstand intermittent exposure to
water, making VariCel filters ideal for installations in humid areas
or where the filters are exposed to moisture.

VARICEL/VARICEL with Intersept

OPERATING DATA

Operating Temperature Limits

Initial Resistance vs. Filter Face Velocity

12" Deep Filters

6" Deep Filters

90-95%

INITIAL RESISTANCE (IN. WG)

90-95% XL/80-85%

VariCel Model

90-95%
60-65%

80-85%

Temperature Limit

Types SH, DH, XL

350F

177C

Type HT-500

500F

260C

Type HT-725

750F

385C

Type HT-900

900F

482C

Type NH

200F

93C

Underwriters Laboratories Inc. Classification: All VariCels are Class1.


Testing was performed according to U.L. Standard 900 and CAN 4-S111.

60-65% XL

PREFILTERS CAN DOUBLE VARICEL LIFE


60-65%

Using prefilters, such as AAF's PerfectPleat pleated filters or 5700 panel filters, will greatly extend the life of
VariCel filters.

FILTER FACE VELOCITY (FPM)

12" deep filters are rated at 500 FPM filter face velocity.
6" deep filters are rated at 250 FPM filter face velocity.
Recommended final resistance for all VariCel filters is 1.2" wg.

OPTIONS
Efficiency by Particle Size*
100

90-95% (MERV 14)

90

VariCel filters can be ordered with faceguards


made of flattened, expanded, aluminized
steel on one or both sides of the filter.

Factory installed gaskets are available on the


front or back of the header.

Vinyl Coated Separators are available for corrosive conditions.

118" Single Header VariCels, designed for


other manufacturers' equipment, are also
available.

80

EFFICIENCY (%)

70
60
50

80-85% (MERV 13)


40
30

60-65% (MERV 11)


20
10
0

.1

.4

.2

.6

.8

8 10

PARTICLE SIZE (MICRONS)


* Tested in accordance with ASHRAE standards 52.2-1999

10300 ORMSBY PARK PL STE 600


LOUISVILLE KY 40223-6169
P O BOX 35690
LOUISVILLE KY 40232-5690
www.aafintl.com
AFP-1-158P

DEC '03

MP 10M

For Additional Information On AAF Products,


Call Customer Service
888.AAF.2003
2003 AAF INTERNATIONAL

VariCel II
Low Depth Compact Filter
For Commercial and Industrial HVAC Systems

Low depth saves space


Classification ranges
F6 and F8
Lightweight and
easy-to-install
Economic to transport
High dust holding
capacity

Initial Resistance vs Face Velocity


Initial Resistance (Pa)

When installation space is limited and high


quality air filtration is required, VariCel II
is the solution. This low depth, lightweight
filter is available in EN779 classification
ranges F6 and F8. It displays low media
resistance which means low energy
consumption. Due to its lightweight and
low depth it is economic to ship compared
to other heavier, bulkier types of filter.

225
90 %

200
175
150
125

60 %

100
75

VariCel II is suitable for use in front, rear


and side access HVAC installations.
The filter is also suitable for use in variable
air volume systems and can withstand
repeated fan shut down and turbulent
airflow. VariCel II has a high dust holding
capacity and long service life. It can resist
intermittent exposure to water and
provides excellent performance in
conditions of high relative humidity.

50
25
0
0

1.0

2.0

3.0

2.5

4.0

Face Velocity (m/s)

VariCel II

Specification

Maximum operating temperature


Media
Filter frame
Disposal

: 65 C
: Dual density glass fibre
: Natural kraft pine and hardwood fibre
: Municipal incinerator

Technical Data
Nominal
Size1)
(wxhxd)
(inches)

Actual
Size1)
(wxhxd)
(mm)

Rated
Air Flow
Capacity2)
(m3/h)

(m3/s)

Rated
Initial2)
Resistance
(Pa)

Gross
Media
Area
(m2)

90% Average Efficiency - F 8


24x24x43)
20x25x4
20x24x43)
20x20x4
18x24x4
16x25x4
16x20x4
12x24x43)
12x12x4

594x594x97
492x619x97
492x594x97
492x492x97
441x594x97
391x619x97
391x492x97
289x594x97
289x289x97

3400
2975
2805
2380
2550
2380
1870
1700
850

0.944
0.826
0.780
0.661
0.708
0.661
0.519
0.472
0.236

170
170
170
170
170
170
170
170
170

11.80
10.31
9.85
8.18
8.83
8.18
6.50
5.85
2.97

3400
2975
2805
2380
2550
2380
1870
1700
850

0.944
0.826
0.780
0.661
0.708
0.661
0.519
0.472
0.236

100
100
100
100
100
100
100
100
100

11.80
10.31
9.85
8.18
8.83
8.18
6.50
5.85
2.97

60% Average Efficiency - F 6


24x24x43)
20x25x4
20x24x43)
20x20x4
18x24x4
16x25x4
16x20x4
12x24x43)
12x12x4

594x594x97
492x619x97
492x594x97
492x492x97
441x594x97
391x619x97
391x492x97
289x594x97
289x289x97

1) Width and height dimensions are interchangeable. VariCel II filters can be installed horizontally or vertically.
2) All performance data based on ASHRAE 52: 1.1992. Classification in accordance with EN779.
For maximum service life, VariCel II filters should always be operated with a prefilter.
3) Available for side access installations designed with a 18 mm or 22 mm or customized wide stationary track.

Underwriters Laboratories Inc. Listing

VariCel II filters are Class 2 approved according to U.L. Standard 900.

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice
RA-2-599-IN-1-0198

1998 AAF International

VariPak
Multi-Purpose High Efficiency Compact Filter

For use as prefilter or fine


filter
F6, F7 and F8 classified
according to EN779
Various media pack depths
and cell side combinations
available
Low resistance = long
service life
Maximum operating
temperature 70C
thermoplastic separators which
maintain uniform spacing between
pleats and ensure low media
resistance: low media resistance
translates into low energy
consumption and long service life.
The filter can be supplied with or
without a one-piece gasket and in
certain configurations with a
faceguard.

VariPak is a multi-purpose air filter.


It can be used as a prefilter to a
HEPA filter operating at low face
velocity or as a fine filter in
commercial HVAC systems at a
recommended face velocity of 1.0 1.5 m/s. The filter is available in the
classification ranges F6, F7 and F8 in
accordance with EN779.

VariPak 80%
250
Initial Resistance Pa

Applications

2
3

200

100
50
0
0

0.2

0.4

0.6

Initial Resistance Pa

90

1.4

1.6

1.8

VariPak 90%

70
60
50
40

2.0

5: 96 mm 1.5 m/s

250

80

30

2
3

200

4
5

150
100
50

20
10

0
0

0.5

1.0

1.5

2,0

0.5

5: 96 mm 1.5 m/s

1.0

1.5

2.0

Face Velocity m/sec.

Face Velocity m/sec.

1: 25 mm 1.0 m/s 3: 48 mm 1.3 m/s


2: 35 mm 1.0 m/s 4: 72 mm 1.5 m/s

1.2

4
Initial Resistance Pa

Depending on the application,


VariPak can be supplied in a wide
variety of mini-pleat media pack
depths and cell side configurations,
including non-shedding MDF,
die-cut, extruded aluminium and
aluminized U-profile. The ultra fine
glass fibre media pack features

1.0

1: 25 mm 1.0 m/s 3: 48 mm 1.3 m/s


2: 35 mm 1.0 m/s 4: 72 mm 1.5 m/s

5
100

0.8

Face Velocity m/sec.

VariPak 60%

The Filter

4
5

150

1: 25 mm 1.0 m/s 3: 48 mm 1.3 m/s


2: 35 mm 1.0 m/s 4: 72 mm 1.5 m/s

5: 96 mm 1.5 m/s

VariPak

Operating Temperature

Disposal

Recommended Final Resistance

VariPak air filters have a maximum


operating temperature of 70C.

MDF and die-cut versions can be


disposed of by incineration. Products
with metal parts can be landfilled.

The recommended final resistance is


450 Pa.

Item
A
B

Component Code Definition

Filter Type
Efficiency

VP = VariPak
6 = 60 - 65%
9 = 80 - 85%
10 = 90 -95%
10 = die - cut, 11 = Aluminium extrusion
72 = MDF
89 = Aluminized steel
99 = Aluminium extrusion
90 = Aluminium extrusion with 20 mm flange for 3 media
P = 25 mm
R = 35 mm
K = 48 mm
M = 96 mm
L = 72 mm
9 = Polyurethane
2 = polyurethane flame retandant
0 = none on filters with die-cut cell sides
S = foamed polyurethane
P = No gasket
T = neoprene 6 mm
A = special
0 = none
2 = air leaving side
1 = air entering side
3 = both sides
P = none
A = Aluminium
E = epoxy coated steel U = Aluminized expanded metal
Z = special
0 = none
1 = Air leaving side
2 = Air entry side
3 = Both sides

Cell sides

Pack Depth

Bond

Standard Sizes and Ratings

Component

Gasket type

Gasket location

Faceguard

Faceguard location

Size in mm
without gasket
H x

W x D

Nominal
airflow
m3/h

m3/s

2000
2000

0,55
0,55

2000
2000

0,55
0,55

1740
1740

0,48
0,48

1340
1340

0,37
0,37

1340
1340

0,37
0,37

96 mm pack
610 x 610 x 292
610 x 610 x 149
72 mm pack
610 x 610 x 292
610 x 610 x 149
48 mm pack
610 x 610 x 78
610 x 610 x 149
35 mm pack
610 x 610 x 78
610 x 610 x 56
25 mm pack
610 x 610 x 78
610 x 610 x 56

How to Order
Below a typical example of the Style Code for a standard VariPak filter using the
Component Definition Code System.
Item
Component
Definition
AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

VP

72

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice
RA-2-509-IN-1-0699

1999 AAF International

VariCel V
Lightweight Compact Filters For Commercial and
Industrial HVAC Systems

Lightweight and
easy to install
Classification ranges
F6, F7, F8 and F9
Excellent performance
in difficult operating
conditions
High air volume capacity:
upto 5000 m3/h
High dust holding
capacity

Airflow Resistance
VV6-series

Due to their 5000m3/h capacity, VariCel V


offer many cost saving benefits. In new
installations fewer filters are needed to
handle the same volume of air compared
to filters of the same size with a lower
capacity. Fewer filters mean less installation
space for the filtration system. They can
also be used in existing systems to increase
the air capacity. VariCel V display low
media resistance and have a high dust
holding capacity and long service life.

Initial Resistance (Pa)

VariCel V are lightweight compact filters


designed for use in industrial and
commercial HVAC installations.
Available in the EN779 classification range
F6 - F9, their rigid design and pleated
media pack with thermoplastic separators
ensure they deliver the desired air quality
when used in variable air volume systems
and subjected to repeated fan shutdown,
high relative humidity and intermittent
exposure to water.

200
175
150
125
100
75
50
25
0

95%
90%
80%
60%

1.0

2.0

3.0
4.0
Face Velocity (m/s)

Varicel V

Specifications
Maximum operating temperature
Media
Separators
Cell Sides

:
:
:
:

70 C
Ultra fine glass fibres woven into mat
Thermoplastic
Recycled polystyrene

Technical Data
Average
Efficiency2)
%

EN
779
Class2

Initial
Resistance
at Nominal
Airflow (Pa)

Final
Resistance3)

60-65
60-65
60-65
80-85
80-85
80-85
90-95
90-95
90-95
> 95
> 95
> 95

6
6
6
7
7
7
8
8
8
9
9
9

110
110
110
125
125
125
145
145
145
180
180
180

600
600
600
600
600
600
600
600
600
600
600
600

Airflow
Type

VV6- 6-24.24-124)
VV6- 6-20.24-124)
VV6- 6-12.24-124)
VV6- 9-24.24-12
VV6- 9-20.24-12
VV6- 9-12.24-12
VV6-10-24.24-12
VV6-10-20.24-12
VV6-10-12.24-12
VV6-11-24.24-12
VV6-11-20.24-12
VV6-11-12.24-12
1)
2)
3)
4)

Size1)
(mm)
HxWxD
592 x 592 x 292
490 x 592 x 292
287 x 592 x 292
592 x 592 x 292
490 x 592 x 292
287 x 592 x 292
592 x 592 x 292
490 x 592 x 292
287 x 592 x 292
592 x 592 x 292
490 x 592 x 292
287 x 592 x 292

Maximum

Nominal

m3/h

m3/s

m3/h

m3/s

5000
4165
2500
5000
4165
2500
5000
4165
2500
5000
4165
2500

1,39
1,15
0,69
1,39
1,15
0,69
1,39
1,15
0,69
1,39
1,15
0,69

4250
3540
2125
4250
3540
2125
4250
3540
2125
4250
3540
2125

1,18
0,98
0,59
1,18
0,98
0,59
1,18
0,98
0,59
1,18
0,98
0,59

(Pa)

Width and height are interchangeable, pleats can be either vertical or horizontal without affecting performance.
All performance data based on EN779.
Recommended maximum value. Filters can be operated to a lower final resistance without materially effecting filter efficiency.
Suffix "C" denotes cellulose media option.

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-2-08-IN-4-0198

1999 AAF International

BioCel I
High Quality HEPA Filter For Use In Clean Zones

Airflow range:
500 - 2000 m3/h
Classified H11 in
accordance with EN1822
Benefits in existing and
new installations
Lower energy costs

As a H11 EN1822 classified filter,


BioCel I is the ideal choice for customers
wishing to upgrade a non-HEPA
installation to a HEPA installation. With
an airflow range of 500 - 2000 m3/h,
BioCel I is ideally suited for variable air
volume and turbulent air flow systems.

Initial Resistance (Pa)

Resistance vs Face Velocity

BioCel I displays low media resistance


which results in lower energy costs and
longer service life. The filter is designed
for use in clean areas in the pharmaceutical, microelectronic, semi-conductor
and healthcare industries in which high
efficiency air filtration on fine particulates
is required. Temperature limit: 90C.

149 mm

250

292 mm

200
150
100
50
0
0

0.37

0.75

1.13

1.5

1.87

2.25

Face Velocity (m/s)

BioCel I

Technical Data
Size
(mm)

Classification Low Airflow


Initial
High Airflow
Initial
Efficiency*
EN1822
m3/h
Resistance (Pa)
m3/h
Resistance (Pa) % @ 0.3 m

610 x 610 x 292


610 x 610 x 149

H11
H11

2000
1000

165
165

3000
1500

250
250

98
98

Media Area
m2
14.6
6.8

* Efficiency % @ MPPS > 95%

Technical Data Standard Execution

Dimensions
Media
Cell sides
Separators
Bond
Gasket
Disposal
Temperature limit
Style code

:
:
:
:
:
:
:
:
:

610 x 610 x 292 mm, 610 x 610 x 149 mm


Submicron glass fibres formed into high density paper
MDF
Corrugated aluminium
Cold cured resin
One piece gasket
Landfill
90 C
D72J9S2F

Note: Non-standard sizes and executions available upon request

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-2-527-IN-1-0897

1997 AAF International

BioPak
High Quality HEPA Filters

H11 classified in
accordance with EN1822
Recessed pack ensures
easy handling
Non-shedding
MDF cell sides
Low resistance ensures
low energy consumption
One-piece gasket
provides leaktight seal

BioPak filters are classified H11 in


accordance with EN1822. They are the
ideal solution for upgrading an existing
non-HEPA HVAC installation into a
HEPA installation. Their recessed minipleat media pack make BioPak filters easy
to handle and install while high quality
MDF cell sides ensure a smooth nonshedding construction. The filter can be
installed with the pleats in the vertical or
horizontal position.

Initial Resistance (Pa)

Resistance vs Face Velocity


250
292 mm
200
150
149 mm
100
50

BioPak filters offer low media resistance


which results in low energy consumption
and long service life. A one-piece gasket
around the perimeter of the filter ensures
leaktight installation. The filters are made
of fully incinerable materials.
Temperature limit: 70C.

0
0

0.30

0.45

0.60

0.75

0.90

1.05

1.20

1.37

1.50

Face Velocity (m/s)

BioPak

Technical Data
Size
(mm)

Classification Low Airflow


Initial
High Airflow
Initial
Efficiency*
EN1822
m3/h
Resistance (Pa)
m3/h
Resistance (Pa) % @ 0.3 m

610 x 610 x 78
610 x 610 x 149
610 x 610 x 292

H11
H11
H11

600
1000
1000

90
120
90

1000
1500
2000

120
180
250

98
98
98

Media Area
m2
8.8
8.8
17.5

* Efficiency % @ MPPS > 95%

Technical Data Standard Execution

Dimensions
Media
Cell sides
Separators
Bond
Gasket
Disposal
Temperature limit
Style code

: 610 x 610 x 292 mm, 610 x 610 x 149 mm,


610 x 610 x 78 mm
: High density paper made from ultra-fine glass fibres
: MDF
: Thermoplastic ribbon
: Cold cured resin
: One piece gasket
: Incineration or landfill
: 70 C
: D72M9S2F for 292 mm depth
D72K9S2F for 149 and 78 mm depth*

* Specify depths acquired

Note: Non-standard sizes and executions available upon request

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-2-539-IN-1-0897

1997 AAF International

BioCel V
High Quality Compact HEPA Filter for HVAC Systems

H10 classification in
accordance with EN1882
High air capacity:
3000 m3/h
Reduced energy costs
and long service life
Lightweight and
easy to install

BioCel V is designed for industrial


HVAC installations in which HEPA
quality air filtration is required. As a H10
EN1882 classified air filter, BioCel V is
ideal for upgrading an existing
non-HEPA HVAC installation to a
HEPA installation. The filters mini-pleat
media provides high quality filtration on
fine particulate matter removing tiny dust
particles from the airstream efficiently.

Initial Resistance (Pa)

Resistance vs Face Velocity


200
180
160
140
120
100
80
60

Because of its 3000 m /h air capacity,


BioCel V is an ideal choice in new
installations as fewer filters are needed to
handle the same volume of air compared
to HEPA filters of the same size with a
lower capacity. Fewer filters means less
installation space. The filter displays low
media resistance which results in low
energy costs and long service life.
Lightweight, BioCel V is easy to handle
and install. Temperature limit: 70C.
3

40
20
0
0

0.37

0.75

1.13

1.5

1.87

2.25

Face Velocity (m/s)

BioCel V

Technical Data
Size
(mm)

Classification
EN1822

592 x 592 x 292


287 x 592 x 292

H10
H10

Low Airflow
Initial
High Airflow
m3/h
Resistance (Pa)
m3/h
2000
1000

120
120

3000
1500

Initial
Efficiency*
Resistance (Pa) % @ 0.3 m
200
250

95
95

Media Area
m2
20.4
9.0

* Efficiency % @ MPPS > 85%

Technical Data Standard Execution

Dimensions
Media
Cell sides
Separators
Disposal
Temperature limit
Style code

:
:
:
:
:
:
:

610 x 610 x 292 mm, 292 x 610 x 292 mm,


Ultra-fine glass fibres formed into a high density paper
Polystyrene
Thermoplastic ribbon
Landfill or incineration
70 C
BV6-2424-12 resp. BV6-1224-12

Note: Non-standard sizes and executions available upon request

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-2-541-IN-2-0899

1999 AAF International

AstroCel I
High Efficiency Particulate Air Filter (HEPA)

Filter class H13 and H14


according to EN1822
Non-shedding
construction
Improves quality of
manufacturing processes
and products

Resistance vs Face Velocity

Initial Resistance (Pa)

AstroCel I filters owe their excellent air


cleaning efficiency to their advanced
design. High quality MDF cell sides
ensure a smooth, non-shedding
construction, while a rigid pleated media
pack with aluminium separators provides
high efficiency air filtration on fine
particulates at the lowest possible
resistance. Galvanized steel and stainless
steel cell sides are also available.
AstroCel I filters are classified H13 and
H14 in accordance with EN1822.
Additional benefits include:
Factory tested to meet the most
stringent legal and industry
requirements.
Easy to install.

400
3

350

300
250
200
150
100
50
0
0

0.25

0.50

0.75

1.0

1.25

1.5

1.75

2.0

2.25

Face Velocity (m/s)

1. 292 mm, H13


2. 292 mm, H14

3. 149 mm, H13


4. 149 mm, H14

AstroCelI
An AstroCel I can be ordered using the following Component Code Definition System.
Use the table to specify a product suitable to your application requirements.

Standard Sizes and Ratings

Selection Table
Item

Component

Component Code Definition*

Media

Cell Sides

C
D

Separators
Bond

Gasket

Gasket Location

Acceptance Level

A
E
24
26
72
J
5
9
P
S
T
Y
0
2
3
H
R

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Size in mm
without gasket1)

Waterproof glass fibre


Waterproof glass fibre
Galvanized steel
Stainless steel
MDF
Aluminium
Silicone
Cold cured resin
No gasket
7 mm, half round profile, one piece foamed
6 mm, flat profile
6,5 mm, silicone rubber
No gasket
One face
Both faces
H13 99.95% @ MPPS, acc. to EN1822
H14 99.995% @ MPPS, acc. to EN1822

* Bold typeface: standard execution

How to Order
Below a typical example of how to order a standard AstroCel I filter using
the Component Code Definition System.
Item

Component
Definition

72

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

Nominal
airflow

m3/h

m3/s

610
610
610
610
610
610

305
610
762
305
610
762

149
149
149
292
292
292

500
1000
1250
1000
2000
2500

0.14
0.28
0.35
0.28
0.56
0.69

1) The H (Height) dimension also indicates


the vertical position of the separators.
AstroCel I filters should always be
installed with the separators in the vertical
position.
2) Other sizes available on request.
Notes:
- Initial resistance at nominal airflow is:
250 Pa for H13 filters
320 Pa for H14 filters.
- Recommended final resistance is 750 Pa.
- Temperature limit: 90C.
(200C for A 24 J 5 Y 2 R,
260C for A 26 J 5 Y 2 R.)

Efficiency
Efficiency
@ 0.3 m
99.997%
99.999%

Efficiency EN1822
@ MPPS
H13
99.95%
H14
99.995%

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-4-701-IN-3-1299

1999 AAF International

AstroCel I HC
High Quality HEPA Filter

High air volume filter:


3000 m3/h
Classified H12, H13 and
H14 according to
EN1822
Space saving design
Saves energy in existing
installations

AstroCel I High Capacity are classified


H12, H13 and H14 in accordance with
EN1822 and are designed for
applications in which a high volume of
air has to be throughput. Because of their
high capacity, fewer filters are needed to
handle the same volume of air compared
to other HEPA filters of the same size.
AstroCel I HC filters owe their high
capacity to a unique separator design
which allows denser packing of the filter
media. The benefits to the customer are
numerous:
In new installations, fewer filters mean
less costly installation space is
necessary.
In existing installations, low pressure
drop means lower energy costs and
longer service life.
Standard individually tested.

Initial Resistance (Pa)

Resistance vs Face Velocity


400

350

300
250
200
150
100
50
0
0

0.25

0.50

0.75

1.0

1.25

1.5

1.75

1. 292 mm, H12 / H13


2. 292 mm, H14

2.0

2.25

Face Velocity (m/s)

AstroCel I HC
An AstroCel I HC can be ordered using the following Component Code Definition System.
Use the table to specify a product suitable to your application requirements.

Standard Sizes and Ratings

Selection Table
Item

Component

Component Code Definition*

Media

Cell Sides

C
D
E

Separators
Bond
Gasket

Gasket Location

A =
E =
24 =
26 =
72 =
H =
9 =
P =
S =
T =
0 =
2 =
3 =
G =
H =
R =

Acceptance Level

Size in mm
without gasket

Waterproof glass fibre


Waterproof glass fibre
Galvanized steel
Stainless steel
MDF
Aluminium (HC pleat)
Cold cured resin
No gasket
7 mm, half round profile, one piece foamed
6 mm, flat profile
No gasket
One face
Both faces
H12 99.5% @ MPPS acc. to EN1822**
H13 99.95% @ MPPS acc. to EN1822
H14 99.995% @ MPPS acc. to EN1822

* Bold typeface: standard execution


** Non leaktested filter

How to Order
Below a typical example of how to order a standard AstroCel I HC filter using the
Component Code Definition System.
Item

Component
Definition

72

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

Nominal
airflow

m3/h

m3/s

610
610
610

305
610
762

292
292
292

1500
3000
3750

0.42
0.83
1.04

1) The H (Height) dimension also indicates


the vertical position of the separators.
AstroCel I HC filters should always be
installed with the separators in the vertical
position.
Notes:
- Initial resistance at nominal airflow is:
300 Pa for H12 / H13 filters
350 Pa for H14 filters.
- Recommended final resistance 750 Pa.
- Temperature limit: 90C.
(200C for A 24 H 5 Y 2 G),
(260C for A 26 H 5 Y 2 G).

Efficiency
Efficiency
@ 0.3 m
99.99%
99.997%
99.999%

Efficiency EN1822
@ MPPS
H12
99.5%
H13
99.95%
H14
99.995%

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-4-721-IN-3-1299

1999 AAF International

AstroPak
High Efficiency Particulate Air Filter

Non-shedding
construction
Leakfree construction
Filter class H13 and H14
according to EN1822

AstroPak filters owe their excellent air


cleaning efficiency to their advanced
design. High quality MDF cell sides
ensure a smooth, non-shedding
construction, while a rigid mini-pleat
media pack with thermoplastic separators
provides high efficiency particulate air
filtration at the lowest possible resistance.
AstroPak filters are classified H13 and
H14 in accordance with EN1822.
Additional benefits include:
Fully incinerable.
Recessed pack ensures easy handling.
Installation with pleats in vertical or
horizontal position.
Also available with metal cell sides.

Initial Resistance (Pa)

Resistance vs Face Velocity


400

350

300
250
200
150
100
50
0
0

0.25

0.50

0.75

1.0

1. 292 mm, H13


2. 78 and 149 mm, H13

1.25

1.5

1.75

Face Velocity (m/s)

AstroPak
An AstroPak can be ordered using the following Component Code Definition System.
Use the table to specify a product suitable to your application requirements.

Standard Sizes and Ratings

Selection Table
Item

Component

Component Code Definition*

Media

Cell Sides

Media pack

D
E

Bond
Gasket

Gasket Location

Acceptance Level

A
E
24
72
K
M
9
P
S
T
0
2
3
H
R

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Size in mm
without gasket1)

Waterproof glass fibre


Waterproof glass fibre
Galvanized steel**
MDF
2 deep - 48 mm.
4 deep - 96 mm
Cold cured resin
No gasket
7 mm, half round profile, one piece foamed
6 mm, flat profile
No gasket
One face
Both faces
H13 Min. 99.95% @ MPPS, acc. to EN1822
H14 Min. 99.995% @ MPPS, acc. to EN1822

* Bold typeface: standard execution


** Cell sides with code number 24 is only available in a limited size range

How to Order
Below a typical example of how to order a standard AstroPak filter using
the Component Code Definition System.
Item
Component
Definition

A
A

B
72

C
K

D
9

Efficiency
Efficiency
@ 0.3 m
99.997%
99.999%

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

Efficiency EN1822
@ MPPS
H13
99.95%
H14
99.995%

E
S

F
2

G
H

Nominal
airflow

Pack
Depth

m3/h

m3/s

mm

240
610
490
610
305
457
305
610
203
305
610
457
610
610
610
610
610
610
762
762
762
762
762
915
915
915
915
305
610
610
610

240
305
490
610
305
457
610
610
203
305
305
457
610
762
915
1220
1524
1830
762
915
1220
1524
1830
915
1220
1524
1830
305
305
610
762

56
56
56
56
78
78
78
78
149
149
149
149
149
149
149
149
149
149
149
149
149
149
149
149
149
149
149
292
292
292
292

155
500
650
1000
250
570
500
1000
110
250
500
570
1000
1250
1500
2000
2500
3000
1600
1900
2500
3150
3800
2250
3000
3800
4550
500
1000
2000
2500

0.04
0.14
0.18
0.28
0.07
0.16
0.14
0.28
0.03
0.07
0.14
0.16
0.28
0.35
0.42
0.56
0.69
0.83
0.44
0.53
0,69
0.88
1.06
0.63
0.83
1.06
1.26
0.14
0.28
0.56
0.69

48
48
48
48
48
48
48
48
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96

1) AstroPak filters can be installed with the


separators in either the horizontal or
vertical position.
2) Always minimal 20 mm difference
between packdepth and filterdepth.
Notes:
- Initial resistance at nominal airflow is:
250 Pa for H13
320 Pa for H14
- Temperature limit: 70C
- Final resistance 500 - 750 Pa

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-3-535-IN-3-1299

1999 AAF International

AstroCel III 3400 MDF


High Efficiency Particulate Air Filters

H12 and H13 in


accordance with EN1822
3400 m3/h air volume
saves space
Low energy consumption
Non-shedding
construction

Resistance vs Face Velocity

Initial Resistance (Pa)

AstroCel III is classified H12 or H13 in


accordance with EN1822. The filter
displays excellent efficiency on fine
particulate matter and is designed for use
in high air volume applications upto
3400 m3/h. Due to its high capacity the
filter has several benefits: in new
installations, fewer filters are required to
handle the same volume of air compared
to HEPA filters of the same size with a
lower capacity. As a result, less
installation space is required and
installation time is significantly reduced.
In existing installations, the filter's high
media area ensures a low pressure drop
which reduces energy costs. Other
benefits include:
high quality MDF cell sides ensure a
smooth, non-shedding construction
easy installation

300
250
200
150
100
50
0
0

0.50

1.00

1.50

2.00

2.50

3.00

Face Velocity (m/s)

AstroCelIII 3400 MDF


An AstroCel III 3400 can be ordered using the following Component Code Definition System.
Use the table to specify a product suitable to your application requirements.

Standard Sizes and Ratings

Selection Table
Item

Component

Component Code Definition*

Size in mm
without gasket

A
B
C
D
E
F

Type of Filter
Media
Cell Sides**
Separators
Bond
Gasket

Gasket Location

Acceptance Level

I
K

Faceguard Location
Options

A39 = AstroCel III


A = Waterproof glass fibre
72 = MDF
C = Thermoplastic
9 = Polyurethane cold cured resin
P = No gasket
S = Polyurethane foam, half round profile, one piece
0 = No gasket
2 = One face
G = H12 Min. 99.5% @ MPPS acc. to EN1822 **
H = H13 Min. 99.5% @ MPPS acc. to EN1822
0 = No faceguard
Consult local sales office

Nominal
airflow

m3/h

610
610

305
610

292
292

1500
3400

Notes:
- Recommended final resistance 750 Pa.
- Temperature limit 70C.
- Initial resistance at nominal airflow: 250 Pa.

Efficiency
Efficiency
@ 0.3 m
99.97%
99.99%

Efficiency EN1822
@ MPPS
H12
99.5%
H13
99.95%

* Bold typeface: standard execution


** Non leaktested filter
For 4000 and NG execution consult specification sheets RA-3-129 en RA-3-124.

How to Order
Below a typical example of how to order a standard AstroCel III 3400 filter using
the Component Code Definition System.
Item
Component
Definition

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

A39

72

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
RA-4-139-IN-3-1299

1999 AAF International

Non-Laminar Flow Cleanrooms


Basic Design and Operating Considerations

In a non-laminar cleanroom or, to use its


official name, non-unidirectional airflow
cleanroom, air enters the room via filters
in the ceiling, and is exhausted via grilles
in the wall close to the floor.
The principle of this technique is based
on allowing air to flow along irregular,
random paths in a turbulent way.

air with dust laden air in the room and


thereby diluting the contamination level
in the cleanroom and lowering the
number of particles per m3. The supply
of clean air is therefore the factor which
determines the success of this technique.
In general, the greater the frequency with
which the air is renewed the lower the
contamination build-up in the room and
the greater the rate with which
impurities are diluted. On an hourly

The success of this technique hinges on


optimizing the mixing of clean incoming

basis, the number of air changes in a


room can vary between 10 and 50,
depending on the type of work and the
achievable Class of the room.
Although more unpredictable than
laminar airflow cleanrooms, in many
applications a non-laminar flow room
can be a cost effective solution, especially
when local laminar flow work stations
are operational in the room.

Non-Laminar Flow Cleanrooms

Basic design and operating considerations


Achievable Class*

1,000 (M4.5)

10,000 (M5.5)

100,000 (M6.5)

Room size (m2)


Room aspect ratio
Room height (m)
Area per occupant (m2)
Equipment in room

100
Narrow
min. 3
20
Minimum

300
3:1
min. 2.75
10
30% Floor

500
2:1
min 2.25
5
50% Floor

Occupant activity
Traffic in/out per hour
Occupants properly attired
Particle generation in room
Thermal updrafts
Housekeeping

Sedentary
1-2
Full gowns
Miniature
None
Meticulous

Occasional movement
2-6
Smocks
Slight
Slight
Good

Constant activity
More than 6
Smocks
Considerable
Considerable
Mediocre

Frivolous activities

Room Pressure (Pa)


Air changes per hour
Airlock

10-15
40-120
Adequate

10-15
20-40
Small

5-10
10-20
None

None

Clean air inlets as % of ceiling area


Clean air inlet locations
Terminal velocity at clean air inlet (m/s)
Return locations
Wall return spacing

20-50
Ceiling
0.15-0.45
Low level or floor
Continuous on all
4 walls
3
0.5-1

10-20
Ceiling
0.15-0.45
Low sidewall
Intermittent on long
walls
6
1-2.5

5-10
Ceiling or high sidewall
0.15-0.45
Sidewall
Non-uniform
9
2.5

50% dust spot eff.


F5
90% dust spot eff.
F8
Quarterly

90% arrestance
G4
80-90% dust spot eff.
F7
Semi-annual

80% arrestance
G4
80-90% dust spot eff.
F7
Annual

Final Filters**

min.99.999% @ 0.3 m
H14

min. 99.99% @ 0.3 m


H13

min. 95% @ 0.3 m


H10

Routine particle count interval

Monthly

Monthly

Quarterly

Max. horizontal distance to return (m)


Return face velocity (m/s)
Prefilters
- First Stage**
- Second Stage**
Prefilter maintenance and inspection

Avoid

Large square room

Street clothes

Floor
Ceiling
Single

Doors open

No schedule

* Class according to US Federal Standard 209E (between brackets in SI)


** G and F classification in accordance with EN779. H classification in accordance with draft EN1822.

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Oslo (N),
Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
CR-2-741-IN-0896

1996 AAF International

Laminar Flow Cleanrooms


Basic Design and Operating Considerations

The principle of laminar airflow or, to


be more precise, unidirectional airflow
cleanrooms is based on air moving along
parallel streamlines at a uniform velocity
of 0.3 to 0.45 m/s with as little
turbulence as possible between the place
where the air enters and exits the room.
The principle is based on expelling any
dust in the airflow by the shortest route.

floor. This downward aiflow flushes


contaminated air particles out of the
room via the floor, thus preventing a
build-up of contaminated particles.
Particles generated at one work station
are therefore removed before they have
the chance to migrate. The air velocity
in this type of cleanroom is usually 0.3
to 0.45 m/s.

Basically, there are two types of laminar


airflow cleanroom:
a) Vertical downflow
b) Horizontal crossflow

Horizontal Crossflow
In a horizontal crossflow cleanroom, the
direction of airflow is from left to right
or right to left across the room. Air
enters the room via filters in one wall
and is exhausted and/or recirculated via
a bank of filters and perforated panels in
the opposite wall. The air velocity has to
be established at a sufficiently high level,

Vertical Downflow
In a vertical downflow cleanroom, air
enters the room via filters in the ceiling
surface and is exhausted via a perforated

usually 0.45 m/s, to counter the effects


of upward thermal movement of
particles. In work stations close to the
high efficiency filter wall, Class 100 or
better is possible.
Since the flow of particles in this type of
cleanroom is in the horizontal direction,
the particle contamination generated at
one work station can be transported to
work stations further downstream of the
filters. This, however, is dependent on
the type of work or the process(es) being
carried out in the cleanroom. Horizontal
crossflow is nevertheless a very practical
and cost effective system, particularly in
cleanrooms which have to be built in
existing spaces with limited ceiling
height.

Laminar Flow Cleanrooms

Basic design and operating considerations


Achievable Class*

1 and 10 (M1.5 and M2.5)

100 (M3.5)

Area per occupant


Occupants properly attired
Occupant activity
Equipment in room
Housekeeping

40 m2
Full gowns
Minimum
Minimum
Meticulous

30 m2
Full gowns
Minimum
Minimum
Meticulous

Room pressurized
Air changes per hour
Air lock

15 Pa
500-600
Yes

15 Pa
500
Yes

Clean air inlets as % of ceiling area


Clean air inlet locations
Terminal velocity at clean air inlet
Return air location

90-100%
Ceiling
0.3 - 0.45 m/s
Perforated floor

90%
Ceiling (wall)
0.3 - 0.45 m/s
Low level or floor
(opposite wall, 0.45 m/s)

30% dust spot efficiency


F5
95% @ 0.3 m
H10
Monthly
Min. 99.9995% on 0.12 m (for Class 10)
U15
Min. 99.99995% on 0.12 m (for Class 1)
U16

50% dust spot efficiency


F5
90% dust spot efficiency
F9
Monthly
Min. 99.999% @ 0.3 um
H14

Daily

Weekly

Prefilters:
- First stage**
- Second stage**
Prefilter maintenance and inspection
Final filters**

Routine particle count interval

* Class according to US Federal Standard 209E (between brackets in SI)


** G and F classification in accordance with EN779. H and U classification in accordance with draft EN1822.

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice.
CR-2-740-IN-0896

1996 AAF International

EN779
New European Standard for Coarse and Fine Filters

Arrestance Filters (Coarse Filters) in


the range G1 - G4. Final pressure
drop for certification is specified at
250 Pa maximum. Filters with an
initial dust spot efficiency above 20%
are classified as Efficiency Filters
(Fine Filters) in the range F5 - F9.
The final pressure drop for
certification is set at 450 Pa
maximum.

In 1993, the European Committee


for Standardization, Technical
Committee 195, Work Group 1
(CEN/TC195-WG1) established a
new standard for general ventilation
filters. With the introduction of this
standard under document name EN
779, member countries of the
European Union are obliged to issue
their own national version of this
standard within the existing
framework of their own national
standards organizations.
For example, BS EN 779 in the U.K.

and DIN EN 779 in Germany.


EN 779 is based on existing
documents such as EUROVENT
4/5, and ASHRAE 52.1:1992, but is
in fact more stringent than either of
these standards. The standard
incorporates a new system of
classification for Coarse and Fine
filters based on an average dust spot
efficiency at a specified final pressure
drop.

Filter
Classification

Average Arrestance
A (%)

Average Efficiency
Em (%)

G1
G2
G3
G4
F5
F6
F7
F8
F9

Am < 65
65 Am < 80
80 Am < 90
90 Am
-

40 Em < 60
60 Em < 80
80 Em < 90
90 Em < 95
95 Em

Initial Dust Spot


Efficiency Eo

Eo < 20%

Eo 20%

The table summarizes the


classification of the EN 779 for
general ventilation filters.

Filters with an initial dust spot


efficiency below 20% are classified as

Note:
For your information, the CEN/TC 195 Work Group 1 will continue to upgrade its standardization for general ventilation filters.
To this end, EUROVENT has produced a particle count method under document name EUROVENT 4/9 which will form the
basis for a future new standard. WG 1 has also expressed its intention to work in closer liaison with ASHRAE on this subject.

AAF-International B.V., P.O. Box 7928, 1008 AC Amsterdam, The Netherlands


Tel.: + 31 20 549 44 11, Fax: + 31 20 644 43 98
B

CR-3-1167-IN-0896

EN1822
New European Standard for HEPA & ULPA Filters

Penetration vs Particle Size

Minimum
Efficiency
Face Velocity 5.00 cm/s
(Resistance = 36.36 mm)
(MPPS = 0.134 m)

Procedure

The filter is assembled with the specified media


grade and amount of media to comply with the
defined media velocity.
The filter is challenged with an aerosol and at the
MPPS both the local and overall efficiency is
determined with either a CNC or laser
spectrometer.

Face Velocity 3.50 cm/s


(Resistance = 26.05 mm)
(MPPS = 0.146 m)

Penetration (%)

On a flat sheet of media, the MPPS is determined


for the given media velocity. This can be done
with a laser spectrometer or a combination of
electrostatic classifier and CNC (Condensed
Nucleus Counter).

Face Velocity 2.50 cm/s


(Resistance = 18.70 mm)
(MPPS = 0.159 m)

Face Velocity 1.70 cm/s


(Resistance = 9.65 mm)
(MPPS = 0.172 m)
Face Velocity 1.30 cm/s
(Resistance = 9.65 mm)
(MPPS = 0.189 m)

Leaks are specified as maximum allowable local


penetration at the MPPS and must not exceed
5 x the overall penetration.

Face Velocity 0.90 cm/s


(Resistance = 6.75 mm)
(MPPS = 0.212 m)

The filter is classified according to the test results


in the range H10 - H14 for HEPA,
U15 - U17 for ULPA.
Particle Size (microns)
Filter
Classification
H 10
H 11
H 12
H 13
H 14
U 15
U 16
U 17

Penetration (%) at the MPPS


Overall Penetration
Local Penetration
15
5
0.5
0.05
0.25
0.005
0.025

Efficiency (%) at the MPPS


Overall Value
Local Value
= > 85
= > 95
= > 99.5
= > 99.95
99.75
= > 99.995
99.975
= > 99.9995
= > 99.99995
= > 99.999995

99.9975
99.99975
99.9999

0.0005
0.00005
0.000005

0.0025
0.00025
0.0001

Notes:
Filters in the class H10, H11 and H12 do not require verification of local penetration.
Filters in the classification H13 and H14 may, as an alternative, be verified with the visual oil-smoke test (previously known as DIN 24.184),
which is accepted as equal or more searching than the specified local penetration.
U17 is an exception to the rule. In this case local penetration may not exceed 20 x the overall penetration value.

AAF-International B.V., P.O. Box 7928, 1008 AC Amsterdam, The Netherlands


Tel.: + 31 20 549 44 11, Fax: + 31 20 644 43 98
B

CR-2-489-IN-1-0398

1998 AAF International

AstroFan FFU
Self-contained Filter Fan Unit

Low energy consumption


Low operating cost
High total static pressure
at full air flow
Easy installation into
cleanroom grids

Application

Construction

Noise level

The AAF AstroFan FFU is a selfcontained ceiling filter fan unit for
use in turbulent mixing and laminar
air flow cleanroom areas. The unit is
designed for use with the AAF
50 and 55 mm T-Bar ceiling grid,
the AstroDry HD ceiling grid and
compatible grids. When executed
with a knife edge, the unit can also
be utilized in the AstroGel ND
liquid seal ceiling grid. The unit is
light weight and easy to install.

The AstroFan unit comprises a mild


galvanized steel housing with a high
performance, encapsulated, direct
driven backward curved fan/motor
combination and a replaceable
HEPA or ULPA AstroCel II filter.
Large units and EC units are made
from aluminium. Options include
an epoxy coated white RAL 9010
housing, which because it can be
decontaminated with disinfectant, is
suitable for sterile applications.

The unit, with a clean filter at full


rated air flow has a single unit SPL
of 52-56 dB(a) at 1m.

AstroFan FFU

Motors and controls

The unit is available with traditional


high efficient AC motors, operating
with single phase or 3 phase motors.
Controls can be either with 5 step
speed controller or stepless controller.
This execution provides a simple and
reliable economical solution for
many applications.
Utilizing EC system (electrical
commutated) external rotor motors
greatly reduces the power
consumption of the unit, because of
reduced losses. Consequently the
cooling requirement is also reduced.

Controls include the electronic


commutation unit, standard single
unit control, standard RFI supression
and PFC (power factor controller )
and LON bus interface. Two wire
twisted cable installation to the bus
makes installation easy. Mains supply
is single phase 230-270V 50/60Hz.

leakfree operation. Selected low


pressure drop of the AstroCel II
provides, in combination with the
high total static pressure of the fan, a
free static pressure of 70-100 Pa at
full rated airflow. This results in
extended filter life or it can be
utilized for external use on prefilters
or cooling coils.

AstroCel II HEPA and ULPA filters

Options

The unit is equipped with HEPA


filters in Class H14 to EN 1822 or
ULPA filters Class U15, U16 or
U17. All filters are factory scanned to
the European Standard to ensure

Room Side Change (RSC)


Cooling coil
Individual ceiling frames
60 Hz operation

Performance Data
Size

66

612

912

1212

Airflow
(m3/h / m3/s?

520 / 0.14

1060 / 0.3

1590 / 0.44

2120 / 0.6

Actual Dimensions
L x W x H* (mm)

570 x 570 x 290

570 x 1170 x 290

870 x 1170 x 350

1170 x 1170 x 350

0.26 kW - 1.2 A
0.21 kW - 0.5 A
0.17 kW - 0.75 A

0.29 kW - 1.3 A
0.23 kW - 0.55 A
0.22 kW - 0.98 A

0.52 kW - 2.2 A
0.43 kW - 0.88 A
0.34 kW - 1.5 A

0.68 kW - 3.0 A
0.61 kW - 1.18 A
0.34 kW - 1.5 A

45
35

65

72

Nominal
Motor Data
230/1/50
400/3/50
EC 230/1/50/60

Approx. weight (kg)


Galv. steel
32
aluminium
25
Other sizes upon request.
* Excluding filter.

AAF-International B.V.
P.O. Box 7928
1008 AC Amsterdam
The Netherlands
Tel.: + 31 20 549 44 11
Fax: + 31 20 644 43 98

International AAF Offices:


Vienna (A), Montreal (CDN), Dortmund (D),
Vitoria (E), Paris (F), Cramlington (GB),
Athens (GR), Milan (I), Riyadh (KSA),
Mexico (Mex), Amsterdam (NL), Singapore,
Istanbul (TR), Louisville, Ky (USA)

AAF Agents:
Copenhagen (DK), Bangalore (IND)
Oslo (N), Lisbon (P), Johannesburg (RSA),
Dalsjfors (S), Malm (S), Helsinki (SF)

AAF has a policy of continuous product research and improvement and reserves the right to change design and
specifications without notice
CR-3-1168-IN-3-0101

2001 AAF International

Potrebbero piacerti anche