Sei sulla pagina 1di 4

DWG Number 145E4544

Rev A

Released 1/10/2013

Page 1 of 4

NOTES:
1. SEE DEVICE SUMMARY MLI 0414 FOR DEVICE SETTINGS AND RATINGS.
2. THE REQUIREMENTS IN THE SYSTEM AND CLEANLINESS SPECIFICATION
INCLUDED IN MLI 0438 APPLY.
3. THE TERM "OTHERS USED ON THIS DRAWING IS DEFINED AS THE PLANT
DESIGNER AND/OR PLANT INSTALLER.

SIZE

DWG. NO.

THIS DOCUMENT SHALL BE


REVISED IN ITS ENTIRETY. ALL
SHEETS OF THIS DOCUMENT
ARE THE SAME REVISION LEVEL
AS INDICATED.

REV.

REVISIONS
DESCRIPTION

REV

DATE

APPROVED

13-01-07

SEE PLM

1. IN SHEET 1, NOTES 16 REVISED


2. IN SHEET 2, PURGE PRESSURE RATIO
TRANSMITTERS ADDED
A

4. REFER TO MLI 4063 CONNECTION AND LINE LIST FOR PROCESS DATA AND
ASSOCIATED NOTES. CONNECTIONS MARKED WITH PC INDICATE
CONNECTION BY OTHERS, CONNECTIONS NOT MARKED WITH PC ARE GEE
GEE CONNECTIONS, REQUIRED NO INTERFACE BY OTHERS, AND ARE NOT
SHOWN ON MLI 4063.
5. ALL DEVICES AND DEVICE SETTINGS OTHER THAN THOSE ASSOCIATED WITH
THE FUEL GAS CONTROL VALVES (MLIS 0507 AND 0509 ) AND PRESSURE
TRANSMITTERS (557T) ARE FOR REFERENCE ONLY. SEE DEVICE SUMMARY
(MLI 0414) FOR RECOMMENDED SETTINGS, RATINGS AND RANGES.

SH.

145E4544

3. IN SHEET 3, AUX STOP VALVE ADDED


ECR0019833
ECO0086374

H
P.SANTHIYAGU

6. FOLLOW AGA REPORT 11 FOR INSTALLATION AND REQUIREMENTS FOR PIPE


LENGTH PRECEDING AND FOLLOWING METER TUBE, MG2-4.
7. A TEMPORARY CONICAL STRAINER SUPPLIED BY G.E. IS TO BE INSTALLED (SEE
MLI A179).
8. REFER TO GAS FUEL STRAINER INSPECTION, CLEANING AND MAINTENANCE
RECOMMENDATIONS INCLUDED ON MLI 0438.
9. CONNECTIONS BETWEEN COMBUSTOR END COVERS AND THE FUEL GAS
SUPPLY MANIFOLDS MUST BE PITCHED SO THAT THERE ARE NO LOW POINTS.
ALL LIQUIDS WILL DRAIN TO EITHER THE FUEL MANIFOLD FOR ALL LOWER
HALF COMBUSTION END COVERS AND/OR TO THE COMBUSTION CAN FOR ALL
UPPER HALF COMBUSTION END COVERS. LIQUID MUST NOT BE PERMITTED
TO DRAIN TO THE LOWER CANS.
10. LOW POINT DRAIN BLANKED FLANGE CONNECTION.
11. SLOPED LINE FROM GAS COMPARTMENT AND MANIFOLD TO LOW
POINT CONNECTION.
12. N/A.
13. OTHERS MUST PROVIDE AN ANSI CLASS VI ISOLATION VALVE UPSTREAM OF
G.E. SUPPLIED EQUIPMENT IN ORDER TO ALLOW THIS EQUIPMENT TO BE
ISOLATED FOR MAINTENANCE ETC.
14. N/A.

15. GAS FUEL MUST MEET GAS FUEL SPECIFICATION PROVIDED ON MLI 0438.
16. PRESSURE TAP FOR DELTA P PRESSURE TRANSMITTERS (MLI 557T)
MUST BE LOCATED SUCH THAT THE LINE WILL SLOPE CONTINUOUSLY BACK
FROM THE PRESSURE TRANSMITTER ARRANGEMENT TO THE MANIFOLD AND
COMPRESSOR DISCHARGE CASING.

A1

17. STRAINER VENTING VALVE HAS PROVISIONS FOR A LOCK AND MUST BE
LOCKED IN THE CLOSED POSITION DURING OPERATION. IN ORDER TO
REMOVE BASKET FOR REPLACEMENT OR CLEANING FOLLOWING
SHUTDOWN, ISOLATE FUEL GAS SUPPLY VIA AN UPSTREAM ANSI CLASS VI
ISOLATION VALVE, VENT PRESSURE IN STRAINER AND ATTACHED PIPING BY
OPENING THE VALVE. VERIFY PRESSURE HAS COMPLETELY VENTED BY
CHECKING PRESSURE GAUGE PI-FG-1 AND BY MONITORING OUTPUT
TRANSMITTER PT 96FG-1 BEFORE REMOVING STRAINER COVER IN
ACCORDANCE WITH STRAINER MANUFACTURERS INSTRUCTIONS IN SERVICE
MANUAL.
18. ISOLATION VALVES HAVE LOCKING PROVISIONS. VALVES TO BE
LOCKED IN THE OPEN POSITION PRIOR TO OPERATION.

19. THE SAFETY SHUTOFF VALVE AND SAFETY SHUTOFF VENT VALVE MUST BE
INSTALLED OUTDOORS. THE PIPING VOLUME BETWEEN THE OUTLET OF
SAFETY SHUTOFF VALVE AND FG1 MUST NOT EXCEED 63.5 CUBIC FEET
(1.8 CUBIC METERS). THE SAFETY SHUTOFF VALVE AND SAFETY SHUTOFF
VENT VALVE MUST BE INSTALLED SUCH THAT THEY ARE PROTECTED
AGAINST ICING.

1
IT.

SPEC, SCHEMATICS AND DIAGRAMS


372A3671
NOMENCLATURE
IDENT
LIST OF COMPLEMENTARY DOCUMENTS

GE CLASS II (INTERNAL NON-CRITICAL)


SIGNATURES

UNLESS OTHERWISE SPECIFIED

DRAW N

DIMENSIONS ARE IN INCHES

ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE ENERGY GAS


TURBINE PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL
ELECTRIC COMPANY, GE ENERGY (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS
BEEN PROVIDED SOLELY FOR THE EXPRESS REASON OF RESTRICTED PRIVATE USE.
ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL
BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO MAKE
NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL
SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL
ELECTRIC COMPANY, GE ENERGY (USA), LLC AND/OR ITS AFFILIATES.

THIRD ANGLE PROJECTION

LIAN, CLAUDIA

CHECKED
ENGRG

DATE
12-09-27

SEE PLM

12-09-27

ELURIPATI, RAVI

12-09-27

ISSUED

SEE PLM

GENERAL ELECTRIC COMPANY


GAS TURBINE

GE Energy

DIAG, SCHEM PP-FUEL GAS

12-09-27

QUALITY

FIRST MADE FOR: ML-9K1WFA163-1


SIZE

SIM TO:

NONE

CAGE CODE

DWG NO

0422

145E4544

SCALE

SHEET

1 of 4

DISTR
TO

COPYRIGHT 2012-2013 GE ENERGY (USA), LLC AND/OR ITS AFFILIATES.

TOLERANCES ON
2 PL DECIMALS
3 PL DECIMALS
ANGLES
FRACTIONS

1
GE Proprietary Information - Class II (Internal) US EAR - NLR

DWG Number 145E4544

Rev A

Released 1/10/2013

Page 2 of 4

SIZE

DWG. NO.

SH.

145E4544

REV.

A2
INSTRUMENT AIR
(BY OTHERS)

VTA

VTA

PDT
96GN-1

PC
FG2

PC
FG3

PC
FG7

FULL BORE ORIFICE


TYPICAL 6 PLACES
TO
PIGTAIL
#18

NO

FG166

SEE NOTE 16
TO
PIGTAIL
# 17

L
NO

AD-5A

FROM MLI 0417, CLG & SLG


AIR SYSTEM, LINE AD-5A

0.136 [3.45 MM] 557T

TYPICAL 18 PLACES

MG1-1

D5
SEE
NOTE 9

0637

TC

INSTRUMENT AIR
(BY OTHERS)
PC
FG440

F
COMBUSTION CHAMBER

PT-G1-2

SEE NOTE 19

SEE NOTE 7

TC

TC

PT-G1-1

PT-G1-3
PDT

FG138

96GN-2

20VG-8

ZS
0962

33VG-8
VTA

NO

ZS

VTA

PC
FG439

VA13-18

SEE NOTE 16
TO
PIGTAIL
# 17

PC
FG438

SAFETY SHUT OFF VENT VALVE

PC
FG427

PM1

VTA

PC
FG425

SEE NOTE 6

FUEL GAS FLOW METER

NO

SEE NOTE 16
TO
PIGTAIL
# 17

TO
PIGTAIL
#18

0.136 [3.45 MM]

TYPICAL 18 PLACES

557T

33VS4-5

VTA

PC
FG426

MG2-4
PC
FG20

L
NO

ZS
PC
FG21

GAS FUEL
SUPPLY

FROM MLI 0417, CLG & SLG


AIR SYSTEM, LINE AD-5C

PDT
96GN-3
H

FG168

SEE NOTE 10

ZS

FT
SEE NOTE 6

AD-5C

PITCH

PITCH
SEE NOTE 11

33VS4-4
96FM-4

FROM MLI 0417, CLG & SLG


AIR SYSTEM, LINE AD-5B

MG1-2

COMBUSTION CHAMBER

20VS4-4

SEE NOTES 13 & 15

TYPICAL 18 PLACES

AD-5B
557T

SEE
NOTE 9

FG139

SEE NOTE 19

0962

0.136 [3.45 MM]

0572
SEE NOTE 7

PC
FG428A

TO
PIGTAIL
#18

FO

INSTRUMENT AIR
(BY OTHERS)
PC
FG428B

NO

FG167

SEE NOTE 10

33VG-9

VTA

PITCH

PITCH
SEE NOTE 11

VS4-4

PC
FG1

0639
SAFETY SHUT OFF VALVE

PM4

SEE NOTE 7

FC

MG1-3
SEE
NOTE 9

FG140

COMBUSTION CHAMBER

0572
0962
SEE SHEET 3
ACCESSORY MODULE
GAS COMPARTMENT

PITCH

PITCH
SEE NOTE 11

SEE NOTE 10

GAS FUEL PIPING

0962

557T

TURBINE COMPARTMENT

1634

A
GE CLASS II (INTERNAL NON-CRITICAL)

ISSUED

GE Energy
LIAN, CLAUDIA
SEE PLM

SIZE

CAGE CODE

DWG. NO.

145E4544

SCALE

SHEET

2 of 4

DISTR
TO

GENERAL ELECTRIC COMPANY


DRAWN

1
GE Proprietary Information - Class II (Internal) US EAR - NLR

DWG Number 145E4544

Rev A

Released 1/10/2013

Page 3 of 4

PC
FG3

AL-87
AL-88
ASW-44
DL-51
DL-52

PT

PT

96FG-2B

96FG-2C

PDS

PI

63FGD-1

FG-1

2
3

145E4544

SH.

REV.

PI
SEE NOTE 18

IA-2

TO MLI 0420, COOLING


WATER SYSTEM

IA-1

TO MLI 0477, PURGE AIR


SYSTEM

2
3

DWG. NO.

PC
FG7

FG-2
2

NO

PT
96FG-2A

SIZE

FROM MLI 0477, FUEL


PURGE, LINE PA-10

PA-10

NO

NO
PDI

PT

FG-3

96FG-1
2
3

NO

PC
FG2

20VG-1

A3

NO

ZS

20VS4-1
NC

OH-2

ZS

OH-2

0509

33VG-4

33VS4-1

FO

0507

SEE NOTE 17

VTA

NC

ZS
VTA

PC
FG1

33VS4-2

VTA

FC

SEE NOTE 8

TC

TC

TC

FTG-1A

FTG-1B

FTG-1C

OH-17

GPL-6

OH-18

GPL-2

GPL-1

VSR-1

NO

FC

FC

VS4-1

PI
D5

VA13-15

VGC-1

SEE SHEET 4

SEE SHEET 4
FG138

0507

PA-4

FROM MLI 0477, FUEL


PURGE, LINE PA-4

OH-2

OH-2

OH-17

0509

TO MLI 0434
HYDRAULIC OIL, LINE OH-19

OH-19

OH-19

PI
PM1

TO MLI 0434
HYDRAULIC OIL, LINE OH-17

GPL-3

NO

FC

TO MLI 0434
HYDRAULIC OIL, LINE OH-18

VGC-2

OH-18

SEE SHEET 4
FG139

OH-2
0509

TO MLI 0434, HYDRAULIC


OIL, LINE OH-20

OH-20

OH-20

PI
PM4

GPL-4
NO

FC

VGC-3

FG140

SEE NOTE 18
FROM MLI 0434,HYDRAULIC
OIL, LINE OH-2

SEE SHEET 4
PA-6

FROM MLI 0477, FUEL


PURGE, LINE PA-6

OH-2
NO

ACCESSORY MODULE GAS COMPARTMENT

A
GE CLASS II (INTERNAL NON-CRITICAL)

ISSUED

GE Energy
LIAN, CLAUDIA
SEE PLM

SIZE

CAGE CODE

DWG. NO.

145E4544

SCALE

SHEET

3 of 4

DISTR
TO

GENERAL ELECTRIC COMPANY


DRAWN

1
GE Proprietary Information - Class II (Internal) US EAR - NLR

DWG Number 145E4544

Rev A

Released 1/10/2013

Page 4 of 4

SIZE

DWG. NO.

145E4544

SH.

REV.

PDI
FH7-1
OH-2

IN

OUT
FH7-1

G
90SR-1
20FGS-1

OH-17

ZE

VH5-1

96SR-1
GPL-1

ZE
96SR-2

VSR-1
SEE SHEET 3

PDI
FH8-1
OH-2

OH-2

IN

OH-18

PDI
FH8-3

IN

20FGC-1

OH-2

OUT

OUT

IN

D
OUT

0509
0509

FH8-1

PDI
FH8-2

FH8-2

OH-19

65GC-1

65GC-2

ZE

GPL-3

ZE

ZE
96GC-3

GPL-4

C
ZE

ZE
96GC-8

ZE

ZE

96GC-6

96GC-9

VGC-2
SEE SHEET 3

VGC-1
SEE SHEET 3

65GC-3

96GC-7

96GC-5

96GC-2

20FGC-3

VH5-4

96GC-4

96GC-1
GPL-2

OH-20

ZE

VH5-3

ZE

VH5-2

20FGC-2

0509

FH8-3

VCG-3
SEE SHEET 3

A
GE CLASS II (INTERNAL NON-CRITICAL)

ISSUED

GE Energy
LIAN, CLAUDIA
SEE PLM

SIZE

CAGE CODE

DWG. NO.

145E4544

SCALE

SHEET

4 of 4

DISTR
TO

GENERAL ELECTRIC COMPANY


DRAWN

1
GE Proprietary Information - Class II (Internal) US EAR - NLR

Potrebbero piacerti anche