Sei sulla pagina 1di 1

Annex A

Proposed overlay laminate and resin selection


Based on the fact that the product is water and the temperature is ambient, but taking into
account that the GRP needs to interface well with the existing steel the following overlay
construction is recommended:
BONDING LAYER
Number of layers

Laminate

Glass

Resin

200g/m to 300g/m
resin primer

none

Derakane 8084

450g/m CSM

Type:E Glass OCF M143


or equivalent

Derakane Momuntum
411-350

Glass

Resin

INNER CORROSION BARRIER


Number of layers Laminate
1

C Tissue layer

Type: Genmat /
Chemmat or equivalent

Derakane Momuntum
411-350

450g/m CSM

Type: OCF M143 or


equivalent

Derakane Momuntum
411-350

Glass

Resin

STRUCTURAL LAMINATE
Number of layers Laminate
By design

450g/m CSM

Type:E Glass OCF M143


or equivalent

Derakane Momuntum
411-350

By design

450g/m WR

Type:E Glass OCF BD


450 or equivalent

Derakane Momuntum
411-350

Glass

Resin

EXTERIOR CHEMICAL BARRIER


Number of layers Laminate
1

C Tissue layer

Type: Genmat /
Chemmat or equivalent

Derakane Momuntum
411-350

Resin rich, waxed top


coat

5-8% of a 5% wax in
styrene solution to be
added to the resin

Derakane Momuntum
411-350