PerhitunganSambunganBracing3HanggarBali

BoltMomentConnection

Beam Connection 3"


1

MATERIAL PROPERTIES
A.

B.

Bolt
Bolt Grade
fy
fu

=
=
=

Gr. 8.8
550
880

MPa
MPa

86.33

mm

56.69

Da

12

Aa

113.10

na

Plate
Plate Grade

mm2

62.204

pcs

0.7829

A-36

fy

2400

kg/cm2

fu
tp

=
=

4100
10

kg/cm2
mm

0.175

12.5
55.98318
84.59681

SUPPORT REACTIONS
Maximum force at flange Base (base on 60% capacity)
P
=
133.4 kN
T
=
133.4 kN
S
=
0.0 kN
M
=
0.0 kNm
=
=

P.e

Mtot

0.00
240.192

11.12

kNcm
kNcm

240.19

kNcm

eccentricity maximum

where,
e

PLATE CALCULATION

V
Mt= M + P.e
P
1
54
86,17

2T

388.9
9

1.8

cm

BOLT CHECK
Shear stress
fs

fs

0.6 x fy

all

act

297

kg/cm2

0.00

kg/cm2

<

fs

all

...OK

TENSION CHECK
Moment actual acting on flange
Mtot

Mtot
240.19
T

T allowable

T
22.24
2

=
=

M+Pe
240.192

kNcm

10.8
22.24

T
kN

0.9 fy bolt
Abolt
55.98

kN

T allowable
55.98

...OK

PLATE CHECK

TENSION CHECK
Moment actual acting on base plate
Mplate

=
=

2T . X

=
=

the distance from center bolt to face member


16 mm

35.584

kNcm

where,
X

Moment capacity of base plate


kg/cm2

fy

2400

Mbp cap

1/6 x B x tp2 x fy x 0.6

where,
B
tp

=
=

16
1

cm
cm

Mplate cap

=
=

Mplate act
35.58
Ratio

3840
38.40

Mplate
cap
38.40

<
<
=

kgcm
kNcm

0.927

...Ok