220KVGRIDSTATIONS
NTDC operates and maintains twelve 500 KV and twenty nine 220 KV Grid Stations, 5077 km of 500 KV transmission
lineand7359kmof220KVtransmissionlineinPakistan.
View500KVGridStations
ViewPotentialConsumers

MAINLINKS
TheCompany
Projects
EnergyResources
TransmissionNetworks
Tenders
Departments
Careers
ViewPersonalFile
OldNTDCMail
ServicesDivision
NPCC
CPPA
GSIS
CPPAG
Downloads
ContactUs

http://www.ntdc.com.pk/Grid200.php

LISTOF220KVGRIDSTATIONS
1

Islamabad

BURHAN

BANNU

DAUDKHEL

MARDAN

SANGJANI

SHAHIBAGH

UNIVERSITY

Lahore

BUNDROAD

GHAKKAR

10

JARANWALA

11

KALASHAHKAKU

12

LUDEWALA

13

NISHATABAD

14

NEWKOTLAKPAT

15

RAVI

16

SARAFRAZNAGAR

17

SIALKOT(SAHOWALA)

18

WAPDATOWN

19

SHALAMAR

20

SUMUNDARIROAD

21

Multan

NEWMUZAFFARGARH

1/7

5/16/2016
HRIS

NationalTransmissionAndDespatchCompanyLimited(NTDC)Pakistan
22

BAWALPUR

23
ERP
HIMS

CONTACTUS
ForHRQuriesClickHere
Email:hr@ntdc.com.pk

VEHARI

24

Hyderabad

HALAROAD

25

QUETTAINDUSTRIAL

26

SIBBI

27

SHIKARPUR

28

T.M.KHAN

29

DAHARKI

30

ROHRI

PROFILEMDNTDC

LISTOF220KVGRIDSTATIONSUNDERCONSTRUCTION

EngineerMuhammadArshadChaudhry

GRIDSTATIONWAPDATOWN,LAHORE

GRIDSTATIONGHAZIROAD,LAHORE

GRIDSTATIONROHRI

GRIDSTATIONKHUZDAR

GRIDSTATIONMANSEHRA

GRIDSTATIONCHISHTIAN

GRIDSTATIONKASOWAL

GRIDSTATIONDADUKHAIL
220KVDaudKhelG/Stn.wascommissionedon25.09.1995with2x160MVA220/132KVPowerT/Fs.TheG/Stn
isbeingfeedfrom500KVG/Stn.Peshawarthrough220KVD/CT/LineandisconnectedwithChashmaNuclear
PowerStationthrough220KVD/CT/Line.220KVDaudKhelG/Stn.isalsoconnectedwith220KVBannuG/Stn
and500KVSh.MuhammadiPeshawarG/Sthrough220KVD/CDaudKhelBannuand220KVSh.Muhammadi
DaudkhelT/Line.OneNo.13MVA,132/11KVPowerT/FisalsoinstalledattheG/Stn.For220KVbays,double
busbarwithone&halfbreakerschemeandfor132KVbydoublebusbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONBANNU
Thenew220/132KVG/Stn.Bannuwith2x160MVA,220/132KVAutoT/FBankswascommencedon07.05.1996
andcommissionedonnoloadbybackfeeding11KVsupplyon19.07.1999.TheGridStationisconnectedwith
220KVDaudkhelG/Sthrough220KVD/CT/Lines.2x26MVApowertransformersarealsoinstalledatthegrid
station.For220KVbaysone&halfbreakersschemeandfor132KVbaysdoublebusbarwithsinglebreaker
schemeisused.
Top

GRIDSTATIONMARDAN
220KV3rdT/Fenergizedon11/90atMardanG/Stn.wascommissionon05.02.1983with2x160MVA,
220/132KVPowerT/Fs.The3rd160MVA,220/132KVPowerT/Fwascommissionduring11/90.TheG/Stn.is
beingfedfromTarbellathrough220KVD/CT/Line.220KVMardanG/Stn.1x26MVA&1x40MVA,132/11KV
PowerT/FsarealsoinstalledattheG/Stn.For220KVbays,doublebusbarwithsinglebreakerschemeandfor
132KVbaysalsodoublebusbarwithsinglebreakerschemeisused.
Top

http://www.ntdc.com.pk/Grid200.php

2/7

5/16/2016

NationalTransmissionAndDespatchCompanyLimited(NTDC)Pakistan

GRIDSTATIONBURHAN
220KVBurhanG/Stn.wascommissionedon01.06.1977with3x160MVA,220/132KVAutoTransformerBanks.
ThegridstationisbeingfedfromTarbelathrough220KVthreeno.circuitsTarbellaBurhantransmissionline.
Onecircuitof220KVisalsoconnectedwithISPRGridStation.OneNo.13MVA,132/11KVpowerT/Fisalso
installedatthegridstation.For220KVbays,doublebusbarwithoneandhalfbreakerschemeisused.For132
KVbuys,doublebusbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONISPR(SANGJANI)
220KVIslamabadPeshawarRoad(Sangjani)G/Stn.hasbeencommissionedon17.12.1998with3x160MVA,
220/132KVPowerT/Fs.TheG/STn.isbeingfedthrough220KVD/CRawatISPRand220KVTarbelaISPR
and220KVBurhanISPRSingleCircuits.TwoNos.132/11KVPowerT/Fsofcapacity10/13MVAeacharealso
installedattheG/Stn.For220KVbays,doublebusbarwithoneandhalfbreakerschemeand132KVbays
doublebusbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONUNIVERSITYISLAMABAD
220KVUniversityGridStationwascommissioned09.10.2004withoneNo.250MVAandoneNo.160MVAAuto
Transformer.ThisGridStationisbeingfedfrom500KVGridStationRawatthrough220KVDoubleCircuit.This
GridStationisalsofeeding02No.20/26MVAAutoTransformers.
For220KVand132KVBaysdoublebusbarsinglebreakerschemerisused.
Top

GRIDSTATIONSHAHIBAGHPESHAWAR
220KVShahiBaghGridStationwascommissionedon28.02.2006with04No.160MVAAutoTransformers.This
GridStationisbeingfedfromBarothathrough220KVsinglecircuitandfrom500KVGridStationSheikh
Muhammadithough220KVsinglecircuit.ThisGridStationisalsofeeding02No.10/13MVAPower
Transformers.
For220KVBaysone&halfbreakerschemeisused.For132KVBaysdoublebusbarwithsinglebreakerschemer
isused.
Top

GRIDSTATIONGAKHAR
132kvGhakharG/Stn.whichwascommissionedduring01/77wasupgradedto220KVlevelwithcommissioning
on11.06.1982.220KVGhakharG/Stn.has04Nos.160MV,220/132KVPowerT/Fsand02Nos.26MVA,
132/11KVPowerT/FsinstalledattheG/Stn.TheG/Stn.isbeingfedfromManglaPowerHousethrough02Nos.
220KVD/CT/Lines.ThisG/Sisalsoconnectedwith220KVG/SSialkotthroughSingleCircuitand500KVNokhar
andManglaPowerHousethroughINOutarrangement
Top

http://www.ntdc.com.pk/Grid200.php

3/7

5/16/2016

NationalTransmissionAndDespatchCompanyLimited(NTDC)Pakistan

GRIDSTATIONSIALKOT
220KVSialkotG/Stn.wascommencedon08.10.1995andcommissionedon11.08.1999with3x160MVA,
220/132KVPowerT/Fsand2x13MVA,132/11KVPowerT/Fs.TheG/Stn.isconnectedwith220KVG/SGhakhar
and220KVG/SK.S.K.throughsinglecircuiteach.For220KVBays,one&halfbreakerschemeisusedandfor
132KVbaysdoublebusbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONKALASHAHKAKU
KalaShahKakuGridStationwascommissionedduring1970with3x160MVA,220/132KVAutoTransformer
Banks.Thisgridstationisconnectedwith220KVManglaP/Housethrough03No.220KVcircuits.ThisG/Sis
alsoconnectedwith500KVGatti,220KVBundRoad,220KVRaviG/Stationsthrough220KVdoublecircuiteach
andalsoconnectedwith220KVSialkotG/Sthrough220KVsinglecircuit.TwoNo.26MVA,132/11KVPowerT/F
isalsoinstalledtheG/Stn.For220KVbaysdoublebusbarwithone&halfbreakerschemeisusedfor132KV
bays,doublebusbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONRAVILAHORE
132KVRaviG/Stn.whichwascommissionedduring1970hasbeenupgradedto220KVlevelwith
commissioningon21.03.1994.220KVRaviG/Stn.has3x250MVA220/132KVPowerT/FsandtwoNos.
132/11KVPowerT/Fseachofcapacity26MVA,132/11KVinstalledintheG/Stn.TheG/Stn.isconnectedto
220KVKalaShahKakuG/Stn.through220KVD/CtwinbundleconductorsRaviKalaShahKakuT/Line.The
G/Stn.isalsoconnectedwith500KVLahore(Sheikhupura)G/Stn.through220KVS/CRaviSKPand220KVS/C
RaviAtlasPowerHouse.For220KV&132KVbaysdoublebusbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONBUNDROADLAHORE
220KVBundRoadG/Stn.wascommissionedon24.06.1988.4x160MVA,220/132KVautotransformersare
installed.Thisgridstationisalsofeeding2x26MVAtransformers.Thisgridstationisconnectedwith500KV
Lahore(Sheikhupura)G/Stn.through04No.220KVT/Linesandalsoconnectedwith220KVKalaShahKakuand
220KVNewKotLakhpathG/Stns.through220KVD/CT/Lines.For220KVbaysdoublebusbarwithone&half
breakerschemeandfor132KVbaysdoublebusbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONKOTLAKHPATLAHORE
220KVKotlakhpatgridstationwascommissionedduring1979with3x250MVA,220/132KVautotransformer
banks.Thegridstationisconnectedwith220KVBundRoadgridstationthrough220KVD/Ctransmissionlines
andalsoconnectedwith500KVLahore(Sheikhupura)gridstationand220KVSarfrazNagargridstationthrough
220KVD/Ctransmissionlines.ThreeNos.26MVA,132/11KVpowertransformersareinstalledatthegridstation.
For220KVbays,aswellasfor132KVbaysdoublebusbarwithsinglebreakerschemeisused.
Top

http://www.ntdc.com.pk/Grid200.php

4/7

5/16/2016

NationalTransmissionAndDespatchCompanyLimited(NTDC)Pakistan
GRIDSTATIONSARFRAZNAGAR
220KVG/Stn.SarfrazNagarwascommissionedon17.04.1995with3x160MVA,220/132KVAutotransformer
Banks.OneNo.Powertransformerofcapacity26MVA,132/11KVisalsoinstalledattheG/Stn.Thegridstation
isconnectedwith220KVNewKotlakpatgridstationthrough220KVD/Ctransmissionlinesandalsoconnected
with220KVYousafwalaG/Stn.through220KVD/CT/Lines.For220KVbays,doublebusbarwithoneandhalf
breakerschemeisused.For132KVbuysdoublebusbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONNISHATABADFAISALABAD
220KVNishatabadG/Stn.wascommissionedon03.03.1960with4x63MVA&1x100MVA,220/132KVAuto
TransformerBanks.2x37.5MVA,132/66KVPowerTransformersarealsoinstalledatthegridstation.Thegrid
stationisbeingfedfrom500KVGattigridstationthrough220KVD/Ctransmissionlineandalsoconnectedwith
220KVSammundriRoadGridStationthrough220KVD/Ctransmissionline.
Top

GRIDSTATIONJARANWALAROADFAISALABAD
220KVJaranwalaRoadFaisalabadG/Stn.wascommissionon08.12.1982.TherearethreeNos.160MVA,
220/132KVAutoTransformersBanksinstalledatthegridstation.The220KVJaranwalaRoadG/Stn.isbeingfed
from500KVGattiG/Stn.through220KVD/C500KVGattiJaranwalaRoadtransmissionline.TwoNos.26MVA,
132/11KVPowerTransformersarealsoinstalledatthegridstation.
For220KVbaysaswell132KVbaysdoublebusbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONSUMMANDRIROADFAISALABAD
220KVSummandriRoadFaisalabadG/Stn.wascommissionedon12.10.1995.3x160MVA,220/132KVAuto
TransformerBanksareinstalled.TheG/Stn.isbeingfedthroughINOUTarrangementof220KVD/CNishatabad
500KVNewMultanT/Line.2x13MVA,132/11KVPowerT/FareinstalledattheG/Stn.
For220KVbays,doublebusbarwithoneandahalfbreakerschemeisused.whereasfor132KVbaysdouble
busbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONLUDEWALASARGODHA
220KVLudewalaG/Stn.wascommissionedwith3x160MVA,220/132KVAutoT/Fs.TheG/Stn.isconnectedto
500KVGattiG/Stn.through220KVD/CT/Lineand220KVChashnupthrough220KVD/CT/Line.Oneno.13MVA
132/11KVpowertransformerisalsofeedingfromthesaidgridstation.For220KVbaysand132KVdoublebus
barwithsinglebreakerschemeisused.
Top

GRIDSTATIONVEHARI

http://www.ntdc.com.pk/Grid200.php

5/7

5/16/2016

NationalTransmissionAndDespatchCompanyLimited(NTDC)Pakistan
220KVVehariG/Stn.wascommissionedon29.03.1998.3x160MVA,220/132KVAutoTransformerBanksare
installedatthegridstation.1x13MVA132/11KVpowertransformerisbeingfedfromthesaidgridstation.The
G/Stn.isconnectedwith500KVYousafWalaG/Stn.through220KVD/CYousafWalaVehariT/Line.The220KV
VehariG/Stn.isalsoconnectedto500KVMultanaswellas220KVKotAdduG/Sthrough220KVS/CT/Lines.
For220KVbays,doublebusbarwithoneandahalfbreakerschemeisused.whereasfor132KVbaysdouble
busbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONBAHAWALPUR
220KVBahawalpurGridStationwascommissionedon28.02.2003.3x160MVAAutoTransformersareinstalledat
theGridStation.ThisGridStationisbeingfedfromMuzafargarhPowerHousethrough220KVDoubleCircuit.
ThisG/SisalsofeedingoneNo.26MVAPowerTransformer.For220KVbays,doublebusbarwithoneanda
halfbreakerschemeisusedwhereasfor132KVbaysdoublebusbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONMUZAFARGARH
220KVMuzafargarhGridStationwascommissionedon30.06.2008.2x160MVAAutoTransformersareinstalledat
theGridStation.ThisGridStationisbeingfedfromTPSMuzaffargarhand500KVMultanGridStationthrough
220KVSingleCircuits.
For220KVbays,doublebusbarwithoneandahalfbreakerschemeisusedwhereasfor132KVbaysdouble
busbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONSIBBI
220KVSibbiGridStationwascommissionedon02.02.1982with2x160MVA,220/132KVAutoTransformer
Banks.TwoNo.13MVA,132/11KVPowerTransformersarealsoinstalledatthegridstation.Thegridstationis
beingfedfromGudduthrough3Nos.220KVcircuits.OneNo.circuitcomingdirectfromGuddutoSibbiand
twocircuitsfromGuddutoSibbihavebeenmadeINOUTatUchPowerHouse.ThisGridStationisalso
connectedwithQuettaIndustrialGridStationthrough220KVDoubleCircuit.
For220KVbays,doublebusbarwithoneandahalfbreakerschemeisused.whereasfor132KVbaysdouble
busbarwithsinglebreakerschemeisused.
Top

GRIDSTATIONQUETTAINDUSTRIALAREA
32kvQuettaIndustrialG/Stn.whichwascommissionedon14.10.1992wasupgradedto220KVlevelwith
commissioningon02.09.1995.220KVQuettaIndustrial.G/Stn.hasthreeNos.160MVA,220/132KVPower
TransformersandtwoNos.132/11KVPowerTransformers(OneNo.26MVA,132/11KVandOneNO.13MVA,
132/11KV)installedattheG/Stn.TheG/Stn.isbeingfedfrom220KVSibbiG/Stn.through220KVD/CSibbi
QuettaIndustrialT/Line.
For220KVbays,doublebusbarwithoneandahalfbreakerschemeisused.whereasfor132KVbaysdouble
busbarwithsinglebreakerschemeisused.
Top

http://www.ntdc.com.pk/Grid200.php

6/7

5/16/2016

NationalTransmissionAndDespatchCompanyLimited(NTDC)Pakistan

GRIDSTATIONHALAROADHYDERABAD
220KVHalaRoadHyderabadG/Stn.wascommissionedon02.06.1990with3x160MVA,220/132KVAuto
Transformer.OneNo.40MVA132/66KVandtwoNos.26MVA,132/11KVpowerT/Fsarealsoinstalledatthe
G/Stn.TheG/Stn.isconnectedto500KVJamshoroG/Stn.through220KVD/CJamshoroHalaRoadT/Line.
Top

GRIDSTATIONSHIKARPUR
220KVShikarpurG/Stn.hasbeencommissionedonnoloadbybackfeeding11KVsupplyonMarch28,2001.
3x160MVA,220/132KVAutoT/Fs.areinstalled.TheG/Stn.isconnectedwithTPSUchandTPSGudduthrough
220KVS/Ceach.TwoNos.132/11KVPowerT/Fseachofcapacity13MVAarealsoinstalledattheG/Stn.
For220KVbays,doublebusbarwithoneandahalfbreakerschemeandfor132KVbays,doublebusbarwith
singlebreakerschemeisused.
Top

GRIDSTATIONT.M.KHANROAD,HYDERABAD
220KVT.M.KhanRoad,HyderabadG/Stn.hasbeencommissionedon30.09.2000with2x160MVA,220/132KV
PowerT/Fs.TheG/Stn.isconnectedthrough220KVD/CT/Lwith500KVJamshoroG/Stn.TwoNos.132/11KV
PowerT/Fseachcapacity13MVAareinstalledattheG/Stn.
For220KVbays,doublebusbarwithoneandahalfbreakerschemeisusedwhereasfor132KVbaysdouble
busbarwithsinglebreakerschemeisused.
Top