Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
a)
CAPACITY CALCULATION:
Q=q*a*b*c*6.7*sqrt(v*d*g)/1000
where Q = Mill Capacity in TPH
q = Specific Mill Capacity
40
v*0.3*density
b)
2.7 Metre
5.4 Metre
30.917072 M3
4.5
40.64
58.244901
Mill Capacity =
29.464744 TPH
Drive Power
w (net)
0.515*G*N*D*U*a
Where W = Power in Kw
G = Grinding Media Load
40.64 Tonne
1.21
1.2
1.3
30.917072
2.8
0.1
2.7
N = Mill RPM
19 RPM
2.7 Metre
U = Torque Factor
0.73
a = Aim Of Gravity
0.6
w (net)
c)
470.28 Kw.
d)
at 90 Degree Celsius
at 90 Degree Celsius
e)
f)
g)
h)
I D Fan Capacity =
65117.47 M3/Hour At 90 Degree Celsius
Static Pressure of I D Fan
Pressure drop across mill =
180 mm
across Grit Seperator160 mm
Twin Cyclone =
150 mm
Ducting =
50 mm
Total Pressure Drop =540 mm
Required Static Pressure = 600 mm
Kg/Kwh
M3
Metre
Metre
Air Velocity * 60
t Of Evaporation
nge in temperature
At 90 Degree Celsius
gree Celsius